Citect SCADA Pricing Synergist SCADA Inc Version 1.4 – October 3, 2012

37
Citect SCADA Pricing Synergist SCADA Inc Version 1.4 – October 3, 2012 Synergist SCADA INC www.SynergistSCADA.com 1

description

Citect SCADA Pricing Synergist SCADA Inc Version 1.4 – October 3, 2012. Synergist SCADA INC www.SynergistSCADA.com. 1. #1 Rule: Always work with your local Schneider Sales Representative to properly price and license your Vijeo Citect SCADA licenses. USB License Keys. - PowerPoint PPT Presentation

Transcript of Citect SCADA Pricing Synergist SCADA Inc Version 1.4 – October 3, 2012

Page 1: Citect  SCADA Pricing Synergist SCADA Inc Version  1.4 – October  3,  2012

Citect SCADA PricingSynergist SCADA Inc

Version 1.4 – October 3, 2012

Synergist SCADA INCwww.SynergistSCADA.com 1

Page 2: Citect  SCADA Pricing Synergist SCADA Inc Version  1.4 – October  3,  2012

#1 Rule:Always work with your local Schneider Sales Representative to properly price and license your Vijeo Citect SCADA licenses

2

Page 3: Citect  SCADA Pricing Synergist SCADA Inc Version  1.4 – October  3,  2012

USB License Keys• Contain License CALs “Client Access Licenses”• CALs are shared across the network to any server that require

it• Typical CALS:

• Full License• Required to run an IO / Alarm / Report / Trend server • Includes 1 client license which can run locally on the server

(Or can be used by another computer if the Computer Setup Wizard Full License box is checked)

• Client • Control Client• View Only Client• Web / Internet Control Client• Web / Internet View Only Client

3

Page 4: Citect  SCADA Pricing Synergist SCADA Inc Version  1.4 – October  3,  2012

SCADA Point Count• Maximum number of runtime variable tags that can be used

by your system

• Memory or Disk variable do NOT count against your points

4

Page 5: Citect  SCADA Pricing Synergist SCADA Inc Version  1.4 – October  3,  2012

Citect’s “Dynamic” Point Count• Citect / Vijeo Citect 7.0 and higher use a “dynamic-point

licensing” model (See Knowledgebase article Q4939 ) • Citect uses the Dynamic Runtime count of all tags used

• Alarms• Trends• Reports• Events• Page Tags• Super Genies• TagRead() and TagWrite() Cicode functions• DDE, OPC, ODBC, ADO or the CTAPI (Historian)

5

Dynamic Runtime Count

Page 6: Citect  SCADA Pricing Synergist SCADA Inc Version  1.4 – October  3,  2012

Variable count != Point count• 1200 Variable Tags defined in your project may not require a

1200 point license.• The runtime Dynamic point count in your project is often

much lower than your total variable count.

6

!WARNING:If the Runtime Dynamic Point Count is ever greater than the license’s point count, a license error will occur and Citect will shutdown.

Page 7: Citect  SCADA Pricing Synergist SCADA Inc Version  1.4 – October  3,  2012

Version Licensing Changes• V2.0 - V6.10

• V7.0, V7.10, V7.20

• V7.3+

Dynamic Runtime Count

Static Tag Count Compile Time

Sum of Dynamic Runtime Count of Each Process

Dynamic Runtime Count 7

Page 8: Citect  SCADA Pricing Synergist SCADA Inc Version  1.4 – October  3,  2012

Tag Count in Citect 7.3+

•No more “Double Point” counting in multi-process mode

•Tags shared by different processes in multi-process mode will now be only counted once

8

Page 9: Citect  SCADA Pricing Synergist SCADA Inc Version  1.4 – October  3,  2012

Viewing The Dynamic Count • Using the Citect Kernel’s “General” View you can see the

current Dynamic count (you may need to resize the window)

9

Page 10: Citect  SCADA Pricing Synergist SCADA Inc Version  1.4 – October  3,  2012

Helpful Citect.ini Parameters• [General]WatermarkedPointCount

Enables displaying of “watermark messages” when the dynamic point count reaches the limit set points

• [General]PointCountHighPercentage at which “watermark message” will be displayed

• [General]PointCountHighHighPercentage at which a 2nd “watermark message” will be displayed

• [General]PointLimitMsgDetermine weather Citect will stop the point limit from being exceeded or simply shutdown. 10

*DISABLED BY DEFAULT

Page 11: Citect  SCADA Pricing Synergist SCADA Inc Version  1.4 – October  3,  2012

Citect CAL License Types

• Full Licenses• Control Client Licenses• Web Control Client Licenses• View-Only Client Licenses• Web View-Only Client Licenses• Speciality Drivers• Historian• Ampla

11

Page 12: Citect  SCADA Pricing Synergist SCADA Inc Version  1.4 – October  3,  2012

Full Licenses

• Full Licenses• A Full license is a scalable HMI/SCADA system

that can be used across all industries. It provides users and Integrators a fullyfeatured, flexible HMI/SCADA system that includes over 100 drivers.

12

Page 13: Citect  SCADA Pricing Synergist SCADA Inc Version  1.4 – October  3,  2012

How Citect Validates a License

13

CAL exists

SCADA Points

VALIDLICENSE

Page 14: Citect  SCADA Pricing Synergist SCADA Inc Version  1.4 – October  3,  2012

Example License Key • SCADA Point Count 42,000• CALs for 1x Full Licenses, 1x Control Client, 1x View Only Client

14

Page 15: Citect  SCADA Pricing Synergist SCADA Inc Version  1.4 – October  3,  2012

1 Full + Dongle key Per Server• Each Physically Separated Server will Require 1 Full License

4 Servers = 4 Dongle Keys with 4 full licenses15

4 Full Licenses1 Display

Client41,392

IO POINTS

42,000SCADA POINT

COUNT

=

Page 16: Citect  SCADA Pricing Synergist SCADA Inc Version  1.4 – October  3,  2012

Required License Key• Here is the required license key for 41,392 points, 4 Servers

and 1 Control Client We will need 4 licenses with this configuration

16

X 4

Page 17: Citect  SCADA Pricing Synergist SCADA Inc Version  1.4 – October  3,  2012

Client Licenses• Clients typically retrieve their licenses from the IO Server’s

license key

17

1 Full License

With 6 Client CALs

42,000SCADA POINT

COUNT

38,832 IO POINTS

Page 18: Citect  SCADA Pricing Synergist SCADA Inc Version  1.4 – October  3,  2012

Required License Key• Here is the required license key for 38,832 points, 1 Server and

6 Control Client We only have 1 server so we only need 1 key with 6 client CALs

18

Page 19: Citect  SCADA Pricing Synergist SCADA Inc Version  1.4 – October  3,  2012

Software Keys• In Citect / Vijeo Citect 7.30 we now have the option of using

Software keys• Please contact your local Schneider Sales Representative for

more details.

19

Page 20: Citect  SCADA Pricing Synergist SCADA Inc Version  1.4 – October  3,  2012

Pricing Citect Licensing• Three Components to Citect Licenses:

•Support Units•License Price•USB Key Price

20

Page 21: Citect  SCADA Pricing Synergist SCADA Inc Version  1.4 – October  3,  2012

Support Units

Listed next to the license price of all software is a “Support Unit”. Multiply the support units by the associated dollar support level price.

21

SUPPORT UNIT X UNIT COST

Page 22: Citect  SCADA Pricing Synergist SCADA Inc Version  1.4 – October  3,  2012

Support Unit Types

• Silver• Citect Upgrades Not Provided

• Gold• Upgrades Provided • Day time support only

• Gold Plus• Upgrades Provided• 24 / 7 Support

22

Page 23: Citect  SCADA Pricing Synergist SCADA Inc Version  1.4 – October  3,  2012

Support Unit Part Numbers

• VJC = Vijeo Citect SCADA• CIT = Citect SCADA

23

Support Type PriceCitect / VijeoCitect Part Numbers Historian Part Numbers Facilities Part Number

Silver $ XXX109102 VJH109102 CIT109139Gold $$ XXX109103 VJH109103 CIT109125GoldPlus $$$ XXX109138 VJH109130 CIT109126

Page 24: Citect  SCADA Pricing Synergist SCADA Inc Version  1.4 – October  3,  2012

Support Unit Part Example

•1500 Point Full License Citect SCADA

•Gold Plus Support

24

Page 25: Citect  SCADA Pricing Synergist SCADA Inc Version  1.4 – October  3,  2012

Sample Support Unit Calculation

25

$$$

$

Page 26: Citect  SCADA Pricing Synergist SCADA Inc Version  1.4 – October  3,  2012

Solution Support Unit Calculation

26

84 Support UnitsX

$ per Gold Plus Unit

Page 27: Citect  SCADA Pricing Synergist SCADA Inc Version  1.4 – October  3,  2012

Single Key Version Upgrade Only

• Allows the customer to do a one-time upgrade to the latest version and does not include access to the website or Technical Support Engineers.

• The upgrade only can be purchased on an individual key but must purchase upgrade for all licenses on the key.

27

Page 28: Citect  SCADA Pricing Synergist SCADA Inc Version  1.4 – October  3,  2012

Support Reinstatement

• If a site has expired more than 3 months then a reinstatement fee applies. This is because upgrades are included in the Gold or GoldPlus Support Offerings.

• In addition, the first year of Gold or GoldPlus Support must be purchased and then the new support dates will be valid a year from purchase date.

28

Page 29: Citect  SCADA Pricing Synergist SCADA Inc Version  1.4 – October  3,  2012

Citect SCADA License Example

• 1500 Point Full License Citect SCADA

29

$$$

Page 30: Citect  SCADA Pricing Synergist SCADA Inc Version  1.4 – October  3,  2012

USB Key Example

30

Page 31: Citect  SCADA Pricing Synergist SCADA Inc Version  1.4 – October  3,  2012

Citect License Total Estimate Example

• 1500 Point Full License Citect SCADA• Gold Plus Support• USB License Key

31

Page 32: Citect  SCADA Pricing Synergist SCADA Inc Version  1.4 – October  3,  2012

Citect License Total Calculation

32

$$$

$

Page 33: Citect  SCADA Pricing Synergist SCADA Inc Version  1.4 – October  3,  2012

Citect License Total Solution

•$ X 84 Gold Plus Support•$$$ License•$ USB Key

•$$$$$$ Total 33

Page 34: Citect  SCADA Pricing Synergist SCADA Inc Version  1.4 – October  3,  2012

Citect License Example #2

• New Vijeo Citect Customer purchasing a 1,500 point Full

• 2 floating View-Only Clients• 1 year of GoldPlus support • USB License Key

34

Page 35: Citect  SCADA Pricing Synergist SCADA Inc Version  1.4 – October  3,  2012

Citect License Example #2 Solution

35

Page 36: Citect  SCADA Pricing Synergist SCADA Inc Version  1.4 – October  3,  2012

Citect Example #3 Multi-Key Order Example

• New CitectSCADA Customer purchasing an Unlimited point Full

• Redundant Full license, • 1 Web View-Only Clients, • 1 Redundant Web View-Only Clients• 2 stand alone Unlimited Control Clients• Software key packs (USB)

36

Page 37: Citect  SCADA Pricing Synergist SCADA Inc Version  1.4 – October  3,  2012

Citect Multi-Key #3 Solution

37