Chute

1
Schematic Layout of Garbage Chute for Typical Floors. GARBAGE ROOM SLOPE SLOPE GULLY TRAP GARBAGE TROLLEY CONTROL PANEL FLOOR SLAB DISCHARGE END FIRE DOOR CLEANING SPRINKLER, 120 ,10 LPM Discharge 0 FLAT STRUCTURAL BRACKET ROOF SLAB SANITATION UNIT VENT WITH BIRD NETTING FINISH FLOOR 1 RISER “ WET 1/2"BIB COCK EXHAUST CONTROL PANEL EXHAUST FAN "L" TYPE BRACKET ANCHOR FASTENER BOTTOM PIVOTED AUTO CLOSING INTAKE HOPPER HOPPER 90 MINUTE FIRE RATED AS PER UL LABEL 10B. (MAX. TEMP. RISE 121°C IN 30MIN.) " FIRE SPRINKLER DOOR FRAME 1 2 PVC PIPE SCHEDULE.40 HORIZON GARBAGE CHUTE DIA. OF CHUTE ISOLATION GATE VALVE FIRE WATER TANK WATER SOURCE TO DRAIN INTERMEDIATE PIECE INTAKE DOOR PIECE

description

GARBAGE CHUTE DETAILS SECTION TYPICAL

Transcript of Chute

  • Advantages of Garbage Chutes

    Facilitates total building garbage collection at

    one single point.

    Garbage disposal with ease & utmost hygiene.

    Reduces Power consumption.

    "Dry" & "Wet" garbage separate collection

    possible.

    Widely used all over the World.

    Reduces manpower.

    Garbage chutes can be installed in

    Residential, commercial buildings and malls.

    In any duct, common lobbies, landings, staircase

    mid-landings, utility ducts, dry balconies and

    kitchens.

    If on floor level, Intake Hoppers shall be at every

    floor level.

    If at mid-landing, Intake Hopper shall be at

    alternate floor level.

    Urban Civilisation & fastgrowing cities are forcing toconstruct Hi-rise residentialand commercial buildings,complexes.

    In this changing scenario, thegarbage collection from everyfloor & its disposal hasbecome a tedious job.

    Garbage chutes are the means to overcome the aboveproblem with ease & utmost hygiene.

    Salient features of Horizon Chutes

    Manufactured & Installed as per BS 1703:2005,

    NFPA 82, IS 6924:2001 and NBC 2005.

    Weather proof Stainless Steel construction.

    Sanitation system for internal cleaning of chutes.

    Cleaning operation by control panel in garbage

    room.

    Disinfectants can be sprayed.

    Exhaust system to give minimum 20-40 air

    changes/hr.

    Intake Hoppers are 90 minute fire rated as per UL

    Label 10B.

    Auto closing Intake Hoppers.

    Discharge end fire door.

    Available in different sizes.

    Schematic Layout of Garbage Chute for

    Typical Floors.

    GARBAGE ROOM

    SLOPE SLOPE

    GULLY TRAP

    GARBAGE TROLLEY

    CONTROL

    PANEL

    FLOORSLAB

    DISCHARGE

    END FIRE

    DOOR

    CLEANINGSPRINKLER,120 ,10 LPMDischarge

    0

    FLAT

    STRUCTURAL

    BRACKET

    ROOFSLAB

    SANITATIONUNIT

    VENT WITH BIRD NETTING

    FINISHFLOOR

    1

    RISER

    WET

    1/2"BIB COCK

    EXHAUSTCONTROL

    PANEL

    EXHAUST

    FAN

    "L" TYPE

    BRACKET

    ANCHOR

    FASTENER

    BOTTOM PIVOTED

    AUTO CLOSING

    INTAKE HOPPER

    HOPPER90 MINUTEFIRE RATEDAS PERUL LABEL 10B.(MAX. TEMP. RISE121C IN 30MIN.)

    " FIRE

    SPRINKLER

    DOOR

    FRAME

    12

    PVC PIPE

    SCHEDULE.40

    HORIZONGARBAGE

    CHUTE

    DIA. OFCHUTE

    ISOLATION GATE VALVE

    FIRE WATERTANK

    WATERSOURCE

    TO DRAIN

    INTERMEDIATE

    PIECE

    INTAKE DOOR

    PIECE

    HORIZON GARBAGE CHUTES