Chromatography Data System: Chromeleon Goes Mass Spectrometry

30
2 The world leader in serving science Streamline Your Laboratory Chromeleon CDS Seminar [Enter location and date here] Chromeleon Goes MS

description

Showing the MS specific Chromeleon Chromatography Data System features and how easy it is to use them Learn more: http://www.thermoscientific.com/en/product/dionex-chromeleon-7-2-chromatography-data-system.html

Transcript of Chromatography Data System: Chromeleon Goes Mass Spectrometry

Page 1: Chromatography Data System: Chromeleon Goes Mass Spectrometry

2

The world leader in serving science

Streamline Your Laboratory

Chromeleon CDS Seminar

[Enter location and date here]

Chromeleon Goes MS

Page 3: Chromatography Data System: Chromeleon Goes Mass Spectrometry

4

Introduction

• How can you include MS in your laboratory CDS?• Currently it’s on a workstation and there is no way to work remotely

• Thermo Scientific™ Dionex™ Chromeleon™ 7.2 Chromatography Data System (CDS) software is the first CDS to support MS instrument control and data processing with all main front-end separation techniques (GC, LC, IC) in an enterprise environment

Page 4: Chromatography Data System: Chromeleon Goes Mass Spectrometry

5

MS is Fully Integrated within Chromeleon CDS

• Extends Chromeleon CDS advantages to routine GC-MS users• Control and monitor MS remotely

with native drivers

• View, edit, and manipulate the running sequence

• Central storage of data with full 21 CFR Part 11 compliance

• Easily start analyses with eWorkflows™

• Full suite of data processing tools

Page 5: Chromatography Data System: Chromeleon Goes Mass Spectrometry

6

MS is Fully Integrated within Chromeleon CDS

• Chromeleon 7.2 CDS provides:• MS-specific data organization at

component level

• Visualization of (large-volume) MS data

• Channel-specific reporting of components

• NIST format for MS Library searching, creation, and compound data import

• Key benefits:• Only need to install, validate and learn

one software package

• Enhanced data security

• Can use all compliance and processing features of Chromeleon CDS

Page 6: Chromatography Data System: Chromeleon Goes Mass Spectrometry

7

MS Data Visualization

Seeing is believing…

Page 7: Chromatography Data System: Chromeleon Goes Mass Spectrometry

8

MS Data Visualization

• Visualizing your MS data is a must, but how easy is it to see what you need to see?

• New tools for MS data viewing:• Total Ion Chromatogram (TIC)

• MS quantitation channel

• Component and channel-centric data views

• Mass spectral plots

• Component traces• Quantitation and confirming ions

Page 8: Chromatography Data System: Chromeleon Goes Mass Spectrometry

9

Component and Channel Centric Data Viewing

Filter box to quickly narrow list of components or

channels

All channels and components listed

and multi-selectable

Components are tagged with tool tips,

indicating analysis results

Page 9: Chromatography Data System: Chromeleon Goes Mass Spectrometry

10

MS Data Views – TIC

Page 10: Chromatography Data System: Chromeleon Goes Mass Spectrometry

11

MS Data Views – MS Quantitation Channel

Results for selected

component

Overlay of all Quantitation XICs

Page 11: Chromatography Data System: Chromeleon Goes Mass Spectrometry

12

MS Data Views – Mass Spectrum Plot

Click on component name or peak and

select mass spectra

Peak apex spectrum

Also show leading/ tailing spectra & library hits – stack or overlay

Click on component name or peak and

select mass spectra

Page 12: Chromatography Data System: Chromeleon Goes Mass Spectrometry

13

MS Data Views – Component Traces

Click on component name or peak

...stacked or overlaidQuantitation and confirmation ions

displayed...

Page 13: Chromatography Data System: Chromeleon Goes Mass Spectrometry

14

• Using SmartLink and Component Traces…

Data Visualization – Multiple Components / Injections

Injections in rows...

...components in columns...and pin

injections / components

Quantitation and confirmation ions

View stacked......or overlaid

Select SmartLink...

Page 14: Chromatography Data System: Chromeleon Goes Mass Spectrometry

15

MS Data Processing

Page 15: Chromatography Data System: Chromeleon Goes Mass Spectrometry

16

MS Data Processing

• With multiple traces and possibly hundreds of components, how can you quickly and easily process your MS data?

• How can you rapidly and accurately setup your component table?

• Existing data processing tools in Chromeleon CDS are now complimented by a suite of MS-specific tools for fast and efficient MS data processing, including:• Easy extracted ion chromatogram (XIC) creation

• Additional MS-specific detection algorithms

• Full processing control on a component-by-component basis

• MS Library searching

Page 16: Chromatography Data System: Chromeleon Goes Mass Spectrometry

17

MS Data Processing

• Apply all existing calibration modes and options to MS• Easy extracted ion chromatogram (XIC) creation• Additional MS-specific detection algorithms

• Genesis, ICIS

• Full processing control on a component-by-component basis• Additional MS-specific parameters in component table – quantitation and

confirming ions, CAS numbers, molecular formulas, etc.

• Import information from existing compound databases, NIST libraries, and raw data with component information in header

• Library search• Ad-hoc and as part of data processing

• For confirmation or identification

• Use NIST and custom built libraries

Page 17: Chromatography Data System: Chromeleon Goes Mass Spectrometry

18

MS Data Processing – Extracted Ion Chromatograms

• Manual extraction of XIC

Right-click on Channels

Right-click on Channel or

MS Plot

Page 18: Chromatography Data System: Chromeleon Goes Mass Spectrometry

19

MS Data Processing – Extracted Ion Chromatograms

• Graphical extraction

Click below the axis...

Page 19: Chromatography Data System: Chromeleon Goes Mass Spectrometry

20

MS Data Processing – Extracted Ion Chromatograms

• Graphical extraction

... and drag out a range

New channel added to list and

displayed

Page 20: Chromatography Data System: Chromeleon Goes Mass Spectrometry

21

Integrated NIST Library Search

• Use NIST libraries for spectral library screening and ad-hoc library search

Library screening results

Page 21: Chromatography Data System: Chromeleon Goes Mass Spectrometry

22

Import from Compound Databases and NIST Libraries

• Quickly populateprocessing method component tables

• Use library searches • NIST

• User libraries

• Use predefined compound data bases• Thermo Scientific™

TraceFinder™ software

• Use Thermo Scientific™ Xcalibur™ .raw files with component info

Page 22: Chromatography Data System: Chromeleon Goes Mass Spectrometry

23

MS Data Reporting

Page 23: Chromatography Data System: Chromeleon Goes Mass Spectrometry

24

MS Data Reporting

• Can be a very time-consuming activity! • Multiple components and traces make generic reporting

tricky, if not impossible• How do you effectively report such large quantities of data?• Several new additions to Chromeleon CDS reporting tools

• New MS based reporting objects• Mass Spectral Plot

• Component Traces Plot

• MS related report variables and tables

• New tools for reporting of large amounts of multi-channel data• Consolidated Report Tables

• Autorepeat Area Enhancements

Page 24: Chromatography Data System: Chromeleon Goes Mass Spectrometry

25

MS Data Reporting

MS peaks often only appear in certain detection channels (filters) – how do you create a report for your peaks of interest?

Page 25: Chromatography Data System: Chromeleon Goes Mass Spectrometry

26

MS Data Reporting – Consolidated Report Tables

Chromeleon CDS Consolidated Report Tables

• Automatically report for the Channel with the highest response

• Useful for reporting large quantities of MS data in a generic, compact table

Page 26: Chromatography Data System: Chromeleon Goes Mass Spectrometry

27

Summary

Page 27: Chromatography Data System: Chromeleon Goes Mass Spectrometry

28

Manage Your Data Centrally with One CDS!

Page 28: Chromatography Data System: Chromeleon Goes Mass Spectrometry

29

Summary

• Enables existing Chromeleon CDS functioning for MS• Comprehensive MS control with native instrument drivers

• Enterprise functionality with industry-leading 24/7 uptime

• Tools for 21 CFR Part 11 / GxP compliance

• Extends data processing to support typical MS quantitation workflows• Multiple dynamically linked Data Views and Component Traces

• Support for multi-channel MS quantitation, reporting and library searches

• Unrivalled spreadsheet-based reporting tools

Page 29: Chromatography Data System: Chromeleon Goes Mass Spectrometry

30

Summary – Bringing It All Together

MS Processing

MS ComponentsMS Views

MS Reports

Chromeleon CDS has all the tools to help you processand report your MS data in the shortest time!

Page 30: Chromatography Data System: Chromeleon Goes Mass Spectrometry

31

Thank You!

Any Questions?