  • chromatography and spectroscopy consumables and spare parts

  • page 1

    1. Syringe filter units 2. Titan syringe filter 3. Target syringe filter 4. Solid phase extraction (SPE) by Macherey-Nagel 5. Thin layer chromatography (TLC) 6. Tablet Dissolution Accessories 7. Sampling Cannulae 8. Vessels 9. Paddles 10. Baskets 11. Capsule Spiral Sinkers 12. Basket sinkers 13. Sample bottles, micro inserts and closures for HPLC 14. Sample bottles and closures for GC 15. Crimping tools 16. Storage system for HPLC and GC columns 17. Guard columns by Altmann Analytik 18. HPLC columns by Altmann Analytik 19. Akzo Nobel Kromasil Columns 20. Chiral columns by Daicel 21. HPLC columns by Grace 22. HPLC columns by Macherey-Nagel 23. SIELC columns 24. Tubing and Fitting by Upchurch 25. Storage System Consumables 26. Degasser 27. Safety caps/waste cap accessories 28. Deuterium lamps for the HPLC laboratory 29. Tungsten lamps for the HPLC laboratory 30. Lamps for Atom Absorption Spectroscopy (AAS) 31. Graphite Tubes by Altmann Analytik 32. Cuvettes 33. Agilent alternative replacement parts 34. Shimadzu alternative replacement parts 35. Waters alternative replacement parts 36. GC/HPLC-Syringes by Hamilton 37. Manual Syringes 38. GC syringes by SGE 39. Ferrules by SGE 40. GC columns by SGE 41. GC columns by Macherey-Nagel

    p. 2-3 p. 4-5 p. 5-6 p. 7-8 p. 9-10 p. 11-13 p. 14-15 p. 16-17 p. 18-19 p. 20-22 p. 23 p. 24 p. 25-28 p. 29-33 p. 34-35 p. 36 p. 37-39 p. 40-41 p. 42-43 p. 44-49 p. 50-51 p. 52-53 p. 54-55 p. 56-59 p. 60 p. 61 p. 62 p. 63 p. 64 p. 64-65 p. 66-67 p. 68 p. 69 p. 70 p. 70-73 p. 74-76 p. 77-80 p. 81-86 p. 87-92 p. 93-95 p. 97-98

    Table of contents

    table of contents – chromatography

  • page 2

    syringe filter units

    membrane pore size membrane diameter

    3 mm 15 mm 25 mm

    CA 0,2 µm - CA2015-100 CA2025-100

    0,45 µm - CA4515-100 CA4525-100

    PA 0,2 µm PA2003-100 PA2015-100 PA2025-100

    0,45 µm PA4503-100 PA4515-100 PA4525-100

    PES 0,2 µm - - PES2025-100

    0,45 µm - - PES4525-100

    PET 0,2 µm - PET2015-100 PET2025-100

    0,45 µm - PET4515-100 PET4525-100

    GF/PET 1,0/0,2 µm - - PETGF2025-100

    1,0/0,45 µm - - PETGF4525-100

    PTFE 0,2 µm PTFE2003-100 PTFE2015-100 PTFE2025-100

    0,45 µm PTFE4503-100 PTFE4515-100 PTFE4525-100

    PVDF 0,2 µm - PVDF2015-100 PVDF2025-100

    0,45 µm - PVDF4515-100 PVDF4525-100

    GF/PVDF 1,0/0,45 µm - - PVDFGF4525-100

    RC 0,2 µm - RC2015-100 RC2025-100

    0,45µm - RC4515-100 RC4525-100

    GF/RC 1,0/0,2 µm - - RCGF2025-100

    1,0/0,45 µm - - RCGF4525-100

    GF 1,0 µm - GF10015-100 GF10025-100

    1. Syringe filter units

    alway s

    in stock

    Syringe filters are used for filtration of suspended matter from liquid sample or gases. Rapid purification and removal of particles is very simple: just place the filter on a syringe, and you are ready for filtration. Contamination of sensitive instrumen- tation by solid impurities can be avoided. Also the lifetime of chromatographic columns and equipmend can be increased.

  • page 3

    Selection of the appropriate filter FILTER SIZE:

    sample volume 5-100 ml 1-5 ml 3 µm particles uhplc, core-shell and hplc columns with

  • page 4

    2. Titan syringe filter

    titan syringe filter

    art.no. description pore size diameter (mm) pack size

    TF42204-NN Titan Syringe Filter, NYLON 0,2 µm 4 100

    TF44504-NN Titan Syringe Filter, NYLON 0,45 µm 4 100

    TF42213-NN Titan Syringe Filter, NYLON 0,2 µm 17 200

    TF44513-NN Titan Syringe Filter, NYLON 0,45 µm 17 200

    TF42225-NN Titan Syringe Filter, NYLON 0,2 µm 30 100

    TF44525-NN Titan Syringe Filter, NYLON 0,45 µm 30 100

    TF41225-NN Titan Syringe Filter, NYLON 1,5 µm 30 100

    TF45025-NN Titan Syringe Filter, NYLON 5 µm 30 100

    TITAN SYRINGE FILTER NYLON use for: • general laboratory filtration • filtration for most HPLC samples

    art.no. description pore size diameter (mm) pack size

    TF42204-NP Titan Syringe Filter, PTFE 0,2 µm 4 100

    TF44504-NP Titan Syringe Filter, PTFE 0,45 µm 4 100

    TF42213-NP Titan Syringe Filter, PTFE 0,2 µm 17 200

    TF44513-NP Titan Syringe Filter, PTFE 0,45 µm 17 200

    TF42225-NP Titan Syringe Filter, PTFE 0,2 µm 30 100

    TF44525-NP Titan Syringe Filter, PTFE 0,45 µm 30 100

    TITAN SYRINGE FILTER PTFE use for: • filtration of aggressive organic, highly basic or hot solutions • filtering of aqueous solutions after prewetting with an alcohol

    art.no. description pore size diameter (mm) pack size

    TF42204-PV Titan Syringe Filter, PVDF 0,2 µm 4 100

    TF44504-PV Titan Syringe Filter, PVDF 0,45 µm 4 100

    TF42213-PV Titan Syringe Filter, PVDF 0,2 µm 17 200

    TF44513-PV Titan Syringe Filter, PVDF 0,45 µm 17 200

    TF44525-PV Titan Syringe Filter, PVDF 0,45 µm 30 100

    TITAN SYRINGE FILTER PVDF use for: • general biological filtration • filtration of samples where high protein recovery is desired

    Please note: Other Dimensions are also available!

  • page 5

    titan syringe filter/target syringe filter

    art.no. description pore size diameter (mm) pack size

    TF52213-RC Titan Syringe Filter, RC 0,2 µm 17 200

    TF54513-RC Titan Syringe Filter, RC 0,45 µm 17 200

    TF52225-RC Titan Syringe Filter, RC 0,2 µm 30 100

    TF54525-RC Titan Syringe Filter, RC 0,45 µm 30 100

    TITAN SYRINGE FILTER RC use for: • low non-specific binding applications • tissue culture media and general biological sample filtration

    art.no. description pore size diameter (mm) pack size

    TF42204-CA Titan Syringe Filter CA 0,2 µm 4 100

    TF44502-CA Titan Syringe Filter CA 0,45 µm 4 100

    TF42213-CA Titan Syringe Filter CA 0,2 µm 17 200

    TF44513-CA Titan Syringe Filter CA 0,45 µm 17 200

    TF42225-CA Titan Syringe Filter CA 0,2 µm 30 100

    TF44525-CA Titan Syringe Filter CA 0,45 µm 30 100

    TITAN SYRINGE FILTER CA use for: • tissue culture media filtration, sensitive biological samples

    3. Target syringe filter

    art.no. description pore size diameter (mm) pack size

    TFF2513-3 PVDF Target Syringe Filter 0,45 µm 17 100

    TFF2513-4 PVDF Target Syringe Filter 0,2 µm 17 100

    TARGET SYRINGE FILTER PVDF use for: • general biological filtration • filtration where high protein recovery is desired

    art.no. description pore size diameter (mm) pack size

    TFF2513-7 RC Target Syringe Filter 0,45 µm 17 100

    TFF2513-8 RC Target Syringe Filter 0,2 µm 17 100

    TARGET SYRINGE FILTER RC use for: • low non-specific binding applications • Tissue culture media and general biological sample filtration

    Please note: Other Dimensions are also available!

  • page 6

    WHAT IS THE DIFFERENCE BETWEEN TITAN3 AND TARGET2 SYRINGE FILTERS?

    both titan3 and target2 provide: titan3 is the premium brand that provides:

    • High-quality filtration solutions • Even higher levels of confidence from stronger housing that prevents leakage and busting

    • Low extractable membranes and housing • 30 mm products pressure rated to 120 psi

    • HPLC performance tested • Most 30 mm devices are provided with a 1 mm boro silicate glass pre-filter (delivering increased filtrate volumes)

    • Plain polypropylene housing • Color coding for easy identification and selection of the correct membrane and pore size

    • 30mm products pressure rated to 100 psi

    • Enhanced Luer Lock inlet which provides secure attachment to syringes

    • Range of filter sizes from 4 mm to 30 mm

    • Low hold-up volume allows for the treatment of small sample volumes with minimal sample loss

    target syringe filter

    TARGET SYRINGE FILTER AND TITAN SYRINGE FILTER

  • page 7

    solid phase extraction (spe) by macherey-nagel

    CHROMABOND C18 EC POLYPROPYLENE COLUMNS: Base material silica gel, pore diameter 60 angström, particle size 45 µm, pH stability 2-8. Recommended use: aflatoxins, amphetamines, antibioatics, antiepileptics, barbiturates, caffeine, drugs, preservatives, fatty acids, nicotine, PAHs, pestiacides, PCBsa, heavy metals, vitamins.

    volume filling quantity packaging unit

    100 mg 200 mg 500 mg 1 g 2 g

    1 ml MN730011 100

    3 ml MN730012 MN730013 50

    6 ml MN730014 MN730015 MN730141 30

    15 ml MN730404 20

    4. Solid phase extraction (SPE) by Macherey-Nagel

    Solid-phase extraction (SPE) is a powerful method for sample preparation that is used today in most laboratories. The SPE shows its performance in a wide range of applications: environmental analysis, pharmaceutical analysis, organic chemistry and food analysis. SPE is used for three important tasks: enrichment of the analyte, removal of interfering components and change of the matrix of the analyte.

    Advantages of the SPE in comparison to classical liquid-liquid extraction:

    1. Reduced consumption of solvents

    2. Great time-saving

    3. Possibility of automation

    4. High continuity in individual sample handling

    article art.no. description quantity

    Complete vacuum chamber for up to 12 columns or cartridges

    MN730150 Glass 1

    Stainless steel connectors MN730106 to avoid cross contamination 12/PAK

    PTFE-connectors MN730564 to avoid cross contamination 12/PAK

    CHROMABOND VACCUM CHAMBER AND ACCESSORIES: