CHIMNEY FLASHING - Gulf Coast Supply...chimney flashing cross section nts notes: 1. chimney flashing...

10
CHIMNEY FLASHING CROSS SECTION CHIMNEY FLASHING CROSS SECTION NTS NTS NOTES: NOTES: 1. CHIMNEY FLASHING TRIM IS INTENDED TO FLASH AROUND CHIMNEYS AND LARGE 1. CHIMNEY FLASHING TRIM IS INTENDED TO FLASH AROUND CHIMNEYS AND LARGE PENETRATIONS. OTHER USE MAY BE ACCEPTABLE IF DESIGNER DETERMINES PENETRATIONS. OTHER USE MAY BE ACCEPTABLE IF DESIGNER DETERMINES FITNESS OF USE. FITNESS OF USE. 2. THIS IS A GENERIC DETAIL FOR GENERAL PURPOSE USE. SPECIAL CONDITIONS 2. THIS IS A GENERIC DETAIL FOR GENERAL PURPOSE USE. SPECIAL CONDITIONS MAY REQUIRE ALTERNATIVE DESIGN BY THE INSTALLER OR ARCHITECT/ENGINEER. MAY REQUIRE ALTERNATIVE DESIGN BY THE INSTALLER OR ARCHITECT/ENGINEER. 3. LARGE PENETRATIONS SUCH AS CHIMNEYS MAY REQUIRE CRICKETS OR OTHER 3. LARGE PENETRATIONS SUCH AS CHIMNEYS MAY REQUIRE CRICKETS OR OTHER DETAILING. CHECK WITH LOCAL BUILDING CODES. DETAILING. CHECK WITH LOCAL BUILDING CODES. 4. USE SIDEWALL DETAILS FOR CHIMNEY SIDES AND ENDWALL DETAIL FOR 4. USE SIDEWALL DETAILS FOR CHIMNEY SIDES AND ENDWALL DETAIL FOR DOWNHILL END OF CHIMNEY. DOWNHILL END OF CHIMNEY. DRIVE PIN OR OTHER DRIVE PIN OR OTHER SUITABLE FASTENER SUITABLE FASTENER CAULKED GROOVE CAULKED GROOVE REGLET OR OTHER REGLET OR OTHER COUNTER FLASHING COUNTER FLASHING CHIMNEY FLASHING CHIMNEY FLASHING WRAP UNDERLAYMENT UP WRAP UNDERLAYMENT UP EDGE OF PENETRATION EDGE OF PENETRATION CHIMNEY OR OTHER CHIMNEY OR OTHER LARGE PENETRATION LARGE PENETRATION ROOF DECKING ROOF DECKING UNDERLAYMENT UNDERLAYMENT METAL PANEL METAL PANEL EXPOSED EXPOSED FASTENER FASTENER INSIDE CLOSURE INSIDE CLOSURE (SEALANT ABOVE (SEALANT ABOVE AND BELOW) AND BELOW) ROOF ROOF SLOPE SLOPE ROOF PENETRATION ROOF PENETRATION (CHIMNEY OR SIMILAR) (CHIMNEY OR SIMILAR) A A C C B B B B CHIMNEY FLASHING PLAN VIEW CHIMNEY FLASHING PLAN VIEW NTS NTS NOTES: NOTES: 1. VIEW AA: CHIMNEY FLASHING CROSS SECTION 1. VIEW AA: CHIMNEY FLASHING CROSS SECTION 2. VIEW BB: SIDE WALL CROSS SECTION, REGLET OPTION 2. VIEW BB: SIDE WALL CROSS SECTION, REGLET OPTION 3. VIEW CC: END WALL CROSS SECTION, REGLET OPTION 3. VIEW CC: END WALL CROSS SECTION, REGLET OPTION 4. FLASH BEGINNING FROM DOWNHILL SIDE; OVERLAP SUCCESSIVE UPHILL 4. FLASH BEGINNING FROM DOWNHILL SIDE; OVERLAP SUCCESSIVE UPHILL FLASHING TO PROVIDE CONTINUOUS DRAINAGE PATH. FLASHING TO PROVIDE CONTINUOUS DRAINAGE PATH. PANEL EDGE (TYP) PANEL EDGE (TYP) PANEL RIB (TYP) PANEL RIB (TYP) CH1 DIMENSIONS CH1 DIMENSIONS NTS NTS NOTES: NOTES: 1. USE DIMENSIONS SHOWN. DO NOT SCALE. 1. USE DIMENSIONS SHOWN. DO NOT SCALE. 2. CH1 CAN BE USED WITH MOST PANEL PROFILES. 2. CH1 CAN BE USED WITH MOST PANEL PROFILES. SPECIFY ROOF PITCH SPECIFY ROOF PITCH 4 1 2 " 12" 12" Details master.dwg Details master.dwg 2/15/2017 2/15/2017 GULF COAST SUPPLY & MFG., LLC GULF COAST SUPPLY & MFG., LLC 14429 SW 2ND PLACE, SUITE G30 14429 SW 2ND PLACE, SUITE G30 NEWBERRY, FL 32669 NEWBERRY, FL 32669 352-498-0778 Fax 352-498-7852 352-498-0778 Fax 352-498-7852 http://www.gulfcoastsupply.com http://www.gulfcoastsupply.com EXPOSED FASTENER TRIMS EXPOSED FASTENER TRIMS CHIMNEY FLASHING CHIMNEY FLASHING

Transcript of CHIMNEY FLASHING - Gulf Coast Supply...chimney flashing cross section nts notes: 1. chimney flashing...

Page 1: CHIMNEY FLASHING - Gulf Coast Supply...chimney flashing cross section nts notes: 1. chimney flashing trim is intended to flash around chimneys and large penetrations. other use may

CHIMNEY FLASHING CROSS SECTIONCHIMNEY FLASHING CROSS SECTIONNTSNTS

NOTES:NOTES:1. CHIMNEY FLASHING TRIM IS INTENDED TO FLASH AROUND CHIMNEYS AND LARGE1. CHIMNEY FLASHING TRIM IS INTENDED TO FLASH AROUND CHIMNEYS AND LARGEPENETRATIONS. OTHER USE MAY BE ACCEPTABLE IF DESIGNER DETERMINESPENETRATIONS. OTHER USE MAY BE ACCEPTABLE IF DESIGNER DETERMINESFITNESS OF USE.FITNESS OF USE.2. THIS IS A GENERIC DETAIL FOR GENERAL PURPOSE USE. SPECIAL CONDITIONS2. THIS IS A GENERIC DETAIL FOR GENERAL PURPOSE USE. SPECIAL CONDITIONSMAY REQUIRE ALTERNATIVE DESIGN BY THE INSTALLER OR ARCHITECT/ENGINEER.MAY REQUIRE ALTERNATIVE DESIGN BY THE INSTALLER OR ARCHITECT/ENGINEER.3. LARGE PENETRATIONS SUCH AS CHIMNEYS MAY REQUIRE CRICKETS OR OTHER3. LARGE PENETRATIONS SUCH AS CHIMNEYS MAY REQUIRE CRICKETS OR OTHERDETAILING. CHECK WITH LOCAL BUILDING CODES.DETAILING. CHECK WITH LOCAL BUILDING CODES.4. USE SIDEWALL DETAILS FOR CHIMNEY SIDES AND ENDWALL DETAIL FOR4. USE SIDEWALL DETAILS FOR CHIMNEY SIDES AND ENDWALL DETAIL FORDOWNHILL END OF CHIMNEY.DOWNHILL END OF CHIMNEY.

DRIVE PIN OR OTHERDRIVE PIN OR OTHERSUITABLE FASTENERSUITABLE FASTENER

CAULKED GROOVECAULKED GROOVE

REGLET OR OTHERREGLET OR OTHERCOUNTER FLASHINGCOUNTER FLASHING

CHIMNEY FLASHINGCHIMNEY FLASHING

WRAP UNDERLAYMENT UPWRAP UNDERLAYMENT UPEDGE OF PENETRATIONEDGE OF PENETRATION

CHIMNEY OR OTHERCHIMNEY OR OTHERLARGE PENETRATIONLARGE PENETRATION

ROOF DECKINGROOF DECKING

UNDERLAYMENTUNDERLAYMENT

METAL PANELMETAL PANEL

EXPOSEDEXPOSEDFASTENERFASTENER

INSIDE CLOSUREINSIDE CLOSURE(SEALANT ABOVE(SEALANT ABOVE

AND BELOW)AND BELOW)

ROOFROOFSLOPESLOPE

ROOF PENETRATIONROOF PENETRATION(CHIMNEY OR SIMILAR)(CHIMNEY OR SIMILAR)

AA

AA

CC

CC

BB BBBB BB

CHIMNEY FLASHING PLAN VIEWCHIMNEY FLASHING PLAN VIEWNTSNTS

NOTES:NOTES:1. VIEW AA: CHIMNEY FLASHING CROSS SECTION1. VIEW AA: CHIMNEY FLASHING CROSS SECTION2. VIEW BB: SIDE WALL CROSS SECTION, REGLET OPTION2. VIEW BB: SIDE WALL CROSS SECTION, REGLET OPTION3. VIEW CC: END WALL CROSS SECTION, REGLET OPTION3. VIEW CC: END WALL CROSS SECTION, REGLET OPTION4. FLASH BEGINNING FROM DOWNHILL SIDE; OVERLAP SUCCESSIVE UPHILL4. FLASH BEGINNING FROM DOWNHILL SIDE; OVERLAP SUCCESSIVE UPHILLFLASHING TO PROVIDE CONTINUOUS DRAINAGE PATH.FLASHING TO PROVIDE CONTINUOUS DRAINAGE PATH.

PAN

EL E

DG

E (T

YP)

PAN

EL E

DG

E (T

YP)

PAN

EL R

IB (T

YP)

PAN

EL R

IB (T

YP)

CH1 DIMENSIONSCH1 DIMENSIONSNTSNTS

NOTES:NOTES:1. USE DIMENSIONS SHOWN. DO NOT SCALE.1. USE DIMENSIONS SHOWN. DO NOT SCALE.2. CH1 CAN BE USED WITH MOST PANEL PROFILES.2. CH1 CAN BE USED WITH MOST PANEL PROFILES.

SPECIFY ROOF PITCHSPECIFY ROOF PITCH

441122""

12"12"

Details master.dwgDetails master.dwg 2/15/20172/15/2017GULF COAST SUPPLY & MFG., LLCGULF COAST SUPPLY & MFG., LLC14429 SW 2ND PLACE, SUITE G3014429 SW 2ND PLACE, SUITE G30NEWBERRY, FL 32669NEWBERRY, FL 32669352-498-0778 Fax 352-498-7852352-498-0778 Fax 352-498-7852

http://www.gulfcoastsupply.comhttp://www.gulfcoastsupply.com

EXPOSED FASTENER TRIMSEXPOSED FASTENER TRIMS

CHIMNEY FLASHINGCHIMNEY FLASHING

Page 2: CHIMNEY FLASHING - Gulf Coast Supply...chimney flashing cross section nts notes: 1. chimney flashing trim is intended to flash around chimneys and large penetrations. other use may

EAVE CROSS SECTIONEAVE CROSS SECTIONNTSNTS

NOTES:NOTES:1. EAVE DRIP AND FASCIA ARE RECOMMENDED FOR USE AT ROOF EAVES.1. EAVE DRIP AND FASCIA ARE RECOMMENDED FOR USE AT ROOF EAVES.DIFFERENT STYLES OF EAVE DRIP ARE AVAILABLE SUBJECT TO DESIGNER'SDIFFERENT STYLES OF EAVE DRIP ARE AVAILABLE SUBJECT TO DESIGNER'SSELECTION. OTHER USE MAY BE ACCEPTABLE IF DESIGNER DETERMINES FITNESSSELECTION. OTHER USE MAY BE ACCEPTABLE IF DESIGNER DETERMINES FITNESSOF USE.OF USE.2. THIS IS A GENERIC DETAIL FOR GENERAL PURPOSE USE. SPECIAL CONDITIONS2. THIS IS A GENERIC DETAIL FOR GENERAL PURPOSE USE. SPECIAL CONDITIONSMAY REQUIRE ALTERNATIVE DESIGN BY THE INSTALLER OR ARCHITECT/ENGINEER.MAY REQUIRE ALTERNATIVE DESIGN BY THE INSTALLER OR ARCHITECT/ENGINEER.

UNDERLAYMENTUNDERLAYMENTINSIDE FASTENERINSIDE FASTENER

EXPOSED FASTENER,EXPOSED FASTENER,TYPTYP

EAVE DRIPEAVE DRIP

FASCIAFASCIA(RECOMMENDED)(RECOMMENDED)

ROOF DECKINGROOF DECKING

EAVE DRIP FASTENER:EAVE DRIP FASTENER:NAIL AT 4" OC OR USENAIL AT 4" OC OR USE

PANCAKE/DECKPANCAKE/DECKSCREW TO MATCHSCREW TO MATCH

PANEL SPACINGPANEL SPACING

FACE SCREWFACE SCREWOPTIONALOPTIONAL

ED1 DIMENSIONSED1 DIMENSIONSNTSNTS

NOTES:NOTES:1. USE DIMENSIONS SHOWN. DO NOT1. USE DIMENSIONS SHOWN. DO NOTSCALE.SCALE.

ED2 DIMENSIONSED2 DIMENSIONSNTSNTS

NOTES:NOTES:1. USE DIMENSIONS SHOWN. DO NOT1. USE DIMENSIONS SHOWN. DO NOTSCALE.SCALE.2. ED2 IS DESIGNED TO FIT OVER2. ED2 IS DESIGNED TO FIT OVERMOST ED1 STYLE EAVE DRIP.MOST ED1 STYLE EAVE DRIP.

223344""

223388""

3½"3½"

ED3 DIMENSIONSED3 DIMENSIONSNTSNTS

NOTES:NOTES:1. USE DIMENSIONS SHOWN. DO NOT1. USE DIMENSIONS SHOWN. DO NOTSCALE.SCALE.2. ED3 IS A 90° DRIP EDGE.2. ED3 IS A 90° DRIP EDGE.

3"3"

223388""

771616

ED3P DIMENSIONSED3P DIMENSIONSNTSNTS

NOTES:NOTES:1. USE DIMENSIONS SHOWN. DO NOT1. USE DIMENSIONS SHOWN. DO NOTSCALE.SCALE.2. ED3P IS FOR SLOPED ROOFS. SPECIFY2. ED3P IS FOR SLOPED ROOFS. SPECIFYPITCH OF ROOF FOR FABRICATION.PITCH OF ROOF FOR FABRICATION.

223388""

16

3"3"SPECIFY ROOF PITCHSPECIFY ROOF PITCH

¾"¾"1¾"1¾"

SPECIFY ROOF PITCHSPECIFY ROOF PITCH

SPECIFY ROOF PITCHSPECIFY ROOF PITCH

Details master.dwgDetails master.dwg 2/15/20172/15/2017GULF COAST SUPPLY & MFG., LLCGULF COAST SUPPLY & MFG., LLC14429 SW 2ND PLACE, SUITE G3014429 SW 2ND PLACE, SUITE G30NEWBERRY, FL 32669NEWBERRY, FL 32669352-498-0778 Fax 352-498-7852352-498-0778 Fax 352-498-7852

http://www.gulfcoastsupply.comhttp://www.gulfcoastsupply.com

EXPOSED FASTENER TRIMSEXPOSED FASTENER TRIMS

EAVE DRIPEAVE DRIP

Page 3: CHIMNEY FLASHING - Gulf Coast Supply...chimney flashing cross section nts notes: 1. chimney flashing trim is intended to flash around chimneys and large penetrations. other use may

SIDEWALL/ENDWALL CROSS SECTIONNTS

NOTES:1. SIDEWALL TRIM IS RECOMMENDED FOR USE WHERE A WALL INTERSECTS A ROOFSECTION PARALLELL TO THE PANEL LENGTH. ENDWALL TRIM IS RECOMMEND WHEREA WALL INTERSECTS A ROOF SECTION PERPENDICULAR TO THE PANEL LENGTH.2. DIFFERENT STYLES OF SIDEWALL ARE AVAILABLE SUBJECT TO DESIGNER'SSELECTION. OTHER USE MAY BE ACCEPTABLE IF DESIGNER DETERMINES FITNESSOF USE.3. DIFFERENT METHODS OF COUNTER FLASHING MAY BE USED TO PROVIDE AWEATHERTIGHT TRANSITION.4. THIS IS A GENERIC DETAIL FOR GENERAL PURPOSE USE. SPECIAL CONDITIONSMAY REQUIRE ALTERNATIVE DESIGN BY THE INSTALLER OR ARCHITECT/ENGINEER.

WALL TRIMEXPOSED FASTENER, TYP

OUTSIDE CLOSURE, TYP

METAL PANEL, TYP

SIDING OR OTHERWALL CLADDING, TYP

LOW PROFILEFASTENER

SW1 DIMENSIONSNTS

NOTES:1. USE DIMENSIONS SHOWN. DO NOT SCALE.2. SW1 IS DESIGNED FOR USE WITH GULFRIB.

4"

312"

EW1 DIMENSIONSNTS

NOTES:1. USE DIMENSIONS SHOWN. DO NOT SCALE.2. EW1 IS DESIGNED FOR USE WITH GULFRIB,GULFPBR, AND 5VCRIMP.

4"

SPECIFY ROOF PITCH

EW2 DIMENSIONSNTS

NOTES:1. USE DIMENSIONS SHOWN. DO NOT SCALE.2. EW1 IS DESIGNED FOR USE WITH GULFRIB,GULFPBR, AND 5VCRIMP.

312"

4"

SPECIFY ROOF PITCH

412"

CLOSED HEM

5"

34"

SW4 DIMENSIONSNTS

NOTES:1. USE DIMENSIONS SHOWN. DO NOT SCALE.2. SW4 IS DESIGNED FOR USE WITH 5V CRIMP.

4"

312"

412"

12"

SW5 DIMENSIONSNTS

NOTES:1. USE DIMENSIONS SHOWN. DO NOT SCALE.2. SW5 IS DESIGNED FOR USE WITH GULFPBR.

4"

312"

5"

114"

"STUCCO STOP" STYLECOUNTER FLASHING

WALL FLASHING WITHINTEGRATED CAULKLIP

CAULK

REGLET STYLECOUNTER FLASHING

DRIVE PIN OR OTHERSUITABLE FASTENER

BUTYL TAPE, TYP

CAULK LIP STYLECOUNTER FLASHING

Details master.dwg 2/15/2017GULF COAST SUPPLY & MFG., LLC14429 SW 2ND PLACE, SUITE G30NEWBERRY, FL 32669352-498-0778 Fax 352-498-7852

http://www.gulfcoastsupply.com

EXPOSED FASTENER TRIMS

SIDEWALL/ENDWALL

Page 4: CHIMNEY FLASHING - Gulf Coast Supply...chimney flashing cross section nts notes: 1. chimney flashing trim is intended to flash around chimneys and large penetrations. other use may

METAL ROOFINGMETAL ROOFINGPANEL (TYP)PANEL (TYP)

RIDGE CAP (RC1, RC2, RC3,RIDGE CAP (RC1, RC2, RC3,RC4, RC18, OR SIMILAR)RC4, RC18, OR SIMILAR)

DECKINGDECKING

UNDERLAYMENTUNDERLAYMENT

VENTED OR SOLIDVENTED OR SOLIDCLOSURE, TYPCLOSURE, TYP(RECOMMENDED)(RECOMMENDED)

EXPOSED FASTENEREXPOSED FASTENER(THROUGH RIDGE CAP(THROUGH RIDGE CAPAND PANEL RIB)AND PANEL RIB) EXPOSED FASTENEREXPOSED FASTENER

(THROUGH PANEL)(THROUGH PANEL)

RIDGE CROSS SECTIONRIDGE CROSS SECTIONNTSNTS`NOTES:`NOTES:

1. RIDGE CAP IS RECOMMENDED FOR USE AT ROOF EAVES. DIFFERENT STYLES OF RIDGE CAP ARE AVAILABLE SUBJECT TO DESIGNER'S1. RIDGE CAP IS RECOMMENDED FOR USE AT ROOF EAVES. DIFFERENT STYLES OF RIDGE CAP ARE AVAILABLE SUBJECT TO DESIGNER'SSELECTION. OTHER USE MAY BE ACCEPTABLE IF DESIGNER DETERMINES FITNESS OF USE.SELECTION. OTHER USE MAY BE ACCEPTABLE IF DESIGNER DETERMINES FITNESS OF USE.2. THIS IS A GENERIC DETAIL FOR GENERAL PURPOSE USE. SPECIAL CONDITIONS MAY REQUIRE ALTERNATIVE DESIGN BY THE INSTALLER OR2. THIS IS A GENERIC DETAIL FOR GENERAL PURPOSE USE. SPECIAL CONDITIONS MAY REQUIRE ALTERNATIVE DESIGN BY THE INSTALLER ORARCHITECT/ENGINEER.ARCHITECT/ENGINEER.3. "NOTCHABLE" RIDGE CAP (RC3 & RC4) IS DESIGNED TO BE FIELD NOTCHED SO THE NOTCHED RIDGE CAP PROVIDES CLOSURE OVER THE RIBS.3. "NOTCHABLE" RIDGE CAP (RC3 & RC4) IS DESIGNED TO BE FIELD NOTCHED SO THE NOTCHED RIDGE CAP PROVIDES CLOSURE OVER THE RIBS.RC3 IS DESIGNED FOR GULF RIB AND RC4 IS DESIGNED FOR 5V.RC3 IS DESIGNED FOR GULF RIB AND RC4 IS DESIGNED FOR 5V.4. CLOSURES (SOLID OR VENTED) ARE RECOMMENDED TO PROVIDE CLOSURE OVER THE RIBS.4. CLOSURES (SOLID OR VENTED) ARE RECOMMENDED TO PROVIDE CLOSURE OVER THE RIBS.5. USE OF VENTED CLOSURE RECOMMENDED WHEN ROOF IS DESIGNED TO VENTILATE AT THE RIDGE.5. USE OF VENTED CLOSURE RECOMMENDED WHEN ROOF IS DESIGNED TO VENTILATE AT THE RIDGE.

RC1 DIMENSIONSRC1 DIMENSIONSNTSNTS

NOTES:NOTES:1. USE DIMENSIONS SHOWN. DO NOT SCALE.1. USE DIMENSIONS SHOWN. DO NOT SCALE.

SPECIFY ROOF PITCHSPECIFY ROOF PITCH

6"6"

RC2 DIMENSIONSRC2 DIMENSIONSNTSNTS

NOTES:NOTES:1. USE DIMENSIONS SHOWN. DO NOT SCALE.1. USE DIMENSIONS SHOWN. DO NOT SCALE.

SPECIFY ROOF PITCHSPECIFY ROOF PITCH

6"6"4⅛"4⅛"⅞"⅞"

1¼"1¼"

RC18 DIMENSIONSRC18 DIMENSIONSNTSNTS

NOTES:NOTES:1. USE DIMENSIONS SHOWN. DO NOT SCALE.1. USE DIMENSIONS SHOWN. DO NOT SCALE.

SPECIFY ROOF PITCHSPECIFY ROOF PITCH

9"9"4¾"4¾"⅞"⅞"

4⅛"4⅛"

RC3/RC4 DIMENSIONSRC3/RC4 DIMENSIONSNTSNTS

NOTES:NOTES:1. USE DIMENSIONS SHOWN. DO NOT SCALE.1. USE DIMENSIONS SHOWN. DO NOT SCALE.2. RC3 IS DESIGNED FOR GULF RIB, RC4 IS DESIGNED FOR 5V.2. RC3 IS DESIGNED FOR GULF RIB, RC4 IS DESIGNED FOR 5V.3. THE NOTCHABLE EDGE MUST BE CUT TO MATCH THE PROFILE OF3. THE NOTCHABLE EDGE MUST BE CUT TO MATCH THE PROFILE OFTHE PANELTHE PANEL

SPECIFY ROOF PITCHSPECIFY ROOF PITCH

6"6"

Details master.dwgDetails master.dwg 2/15/20172/15/2017GULF COAST SUPPLY & MFG., LLCGULF COAST SUPPLY & MFG., LLC14429 SW 2ND PLACE, SUITE G3014429 SW 2ND PLACE, SUITE G30NEWBERRY, FL 32669NEWBERRY, FL 32669352-498-0778 Fax 352-498-7852352-498-0778 Fax 352-498-7852

http://www.gulfcoastsupply.comhttp://www.gulfcoastsupply.com

EXPOSED FASTENER TRIMSEXPOSED FASTENER TRIMS

RIDGE CAPRIDGE CAP

Page 5: CHIMNEY FLASHING - Gulf Coast Supply...chimney flashing cross section nts notes: 1. chimney flashing trim is intended to flash around chimneys and large penetrations. other use may

DECKINGDECKING

UNDERLAYMENTUNDERLAYMENT

HIGH SIDE RIDGE CAPHIGH SIDE RIDGE CAP(HS1, HS5, HS7, OR(HS1, HS5, HS7, OR

SIMILAR)SIMILAR)

METAL PANELMETAL PANEL

EXPOSEDEXPOSEDFASTENER (TYP)FASTENER (TYP)

CLOSURECLOSURE

FASCIA (FA4, FA5,FASCIA (FA4, FA5,FA6, OR SIMILAR)FA6, OR SIMILAR)

FASCIA BOARDFASCIA BOARD

HIGH SIDE RIDGE CROSS SECTIONHIGH SIDE RIDGE CROSS SECTIONNTSNTS

NOTES:NOTES:1. HIGH SIDE RIDGE CAP IS RECOMMENDED FOR USE AT THE RIDGE OF A1. HIGH SIDE RIDGE CAP IS RECOMMENDED FOR USE AT THE RIDGE OF AMONOSLOPE ROOF. DIFFERENT STYLES OF RIDGE CAP ARE AVAILABLE SUBJECT TOMONOSLOPE ROOF. DIFFERENT STYLES OF RIDGE CAP ARE AVAILABLE SUBJECT TODESIGNER'S SELECTION. OTHER USE MAY BE ACCEPTABLE IF DESIGNERDESIGNER'S SELECTION. OTHER USE MAY BE ACCEPTABLE IF DESIGNERDETERMINES FITNESS OF USE.DETERMINES FITNESS OF USE.2. THIS IS A GENERIC DETAIL FOR GENERAL PURPOSE USE. SPECIAL CONDITIONS2. THIS IS A GENERIC DETAIL FOR GENERAL PURPOSE USE. SPECIAL CONDITIONSMAY REQUIRE ALTERNATIVE DESIGN BY THE INSTALLER OR ARCHITECT/ENGINEER.MAY REQUIRE ALTERNATIVE DESIGN BY THE INSTALLER OR ARCHITECT/ENGINEER.4. CLOSURES (SOLID OR VENTED) ARE RECOMMENDED TO PROVIDE CLOSURE OVER4. CLOSURES (SOLID OR VENTED) ARE RECOMMENDED TO PROVIDE CLOSURE OVERTHE RIBS.THE RIBS.5. USE OF VENTED CLOSURE RECOMMENDED WHEN ROOF IS DESIGNED TO5. USE OF VENTED CLOSURE RECOMMENDED WHEN ROOF IS DESIGNED TOVENTILATE AT THE RIDGE.VENTILATE AT THE RIDGE.

FASCIA FASTENER (NAIL OR LOWFASCIA FASTENER (NAIL OR LOWPROFILE SCREW) RECOMMENDEDPROFILE SCREW) RECOMMENDED

12" MAX OC SPACING12" MAX OC SPACING

HS1 DIMENSIONSHS1 DIMENSIONSNTSNTS

NOTES:NOTES:1. USE DIMENSIONS SHOWN. DO NOT SCALE.1. USE DIMENSIONS SHOWN. DO NOT SCALE.2. HS1 IS DESIGNED FOR USE WITH GULFRIB.2. HS1 IS DESIGNED FOR USE WITH GULFRIB.

6"6"

SPECIFY ROOF PITCHSPECIFY ROOF PITCH

7/16"7/16"

3"3"

HS5 DIMENSIONSHS5 DIMENSIONSNTSNTS

NOTES:NOTES:1. USE DIMENSIONS SHOWN. DO NOT SCALE.1. USE DIMENSIONS SHOWN. DO NOT SCALE.2. HS5 IS DESIGNED FOR USE WITH GULFPBR.2. HS5 IS DESIGNED FOR USE WITH GULFPBR.

5½"5½"

SPECIFY ROOF PITCHSPECIFY ROOF PITCH

7/16"7/16"

3½"3½"

HS7 DIMENSIONSHS7 DIMENSIONSNTSNTS

NOTES:NOTES:1. USE DIMENSIONS SHOWN. DO NOT SCALE.1. USE DIMENSIONS SHOWN. DO NOT SCALE.2. HS7 IS DESIGNED FOR USE WITH GULFLOK.2. HS7 IS DESIGNED FOR USE WITH GULFLOK.

5½"5½"

SPECIFY ROOF PITCHSPECIFY ROOF PITCH

7/16"7/16"

3"3"

Details master.dwgDetails master.dwg 2/15/20172/15/2017GULF COAST SUPPLY & MFG., LLCGULF COAST SUPPLY & MFG., LLC14429 SW 2ND PLACE, SUITE G3014429 SW 2ND PLACE, SUITE G30NEWBERRY, FL 32669NEWBERRY, FL 32669352-498-0778 Fax 352-498-7852352-498-0778 Fax 352-498-7852

http://www.gulfcoastsupply.comhttp://www.gulfcoastsupply.com

EXPOSED FASTENER TRIMSEXPOSED FASTENER TRIMS

HIGH SIDE CAPHIGH SIDE CAP

Page 6: CHIMNEY FLASHING - Gulf Coast Supply...chimney flashing cross section nts notes: 1. chimney flashing trim is intended to flash around chimneys and large penetrations. other use may

VALLEY CROSS SECTIONVALLEY CROSS SECTIONNTSNTS

NOTES:NOTES:1. VALLEY FLASHING IS USED AT THE LOW POINT WHERE TWO ROOF SECTIONS1. VALLEY FLASHING IS USED AT THE LOW POINT WHERE TWO ROOF SECTIONSMEET. DIFFERENT STYLES ARE AVAILABLE SUBJECT TO DESIGNER'S SELECTION.MEET. DIFFERENT STYLES ARE AVAILABLE SUBJECT TO DESIGNER'S SELECTION.OTHER USE MAY BE ACCEPTABLE IF DESIGNER DETERMINES FITNESS OF USE.OTHER USE MAY BE ACCEPTABLE IF DESIGNER DETERMINES FITNESS OF USE.2. THIS IS A GENERIC DETAIL FOR GENERAL PURPOSE USE. SPECIAL CONDITIONS2. THIS IS A GENERIC DETAIL FOR GENERAL PURPOSE USE. SPECIAL CONDITIONSMAY REQUIRE ALTERNATIVE DESIGN BY THE INSTALLER OR ARCHITECT/ENGINEER.MAY REQUIRE ALTERNATIVE DESIGN BY THE INSTALLER OR ARCHITECT/ENGINEER.

DECKINGDECKING

UNDERLAYMENTUNDERLAYMENT(SELF-ADHERING RECOMMENDED(SELF-ADHERING RECOMMENDED

FOR USE IN VALLEYS)FOR USE IN VALLEYS)

EXPOSED FASTENEREXPOSED FASTENER(TYP)(TYP)

METAL PANELMETAL PANEL(TYP)(TYP)

EXPANDING FOAMEXPANDING FOAM(TYP)(TYP)

VALLEY (PV1, PV2,VALLEY (PV1, PV2,OR SIMILAR)OR SIMILAR)

MIN 2" REVEALMIN 2" REVEAL

MIN 6" OVERLAPMIN 6" OVERLAP

1"1"

9"9"

CLOSED HEMCLOSED HEMPV2 DIMENSIONSPV2 DIMENSIONS

NTSNTSNOTES:NOTES:1. USE DIMENSIONS SHOWN. DO NOT SCALE.1. USE DIMENSIONS SHOWN. DO NOT SCALE.2. PV2 CAN BE USED WITH MOST PROFILES AND2. PV2 CAN BE USED WITH MOST PROFILES ANDFOR MOST PROJECTSFOR MOST PROJECTS

Details master.dwgDetails master.dwg 2/15/20172/15/2017GULF COAST SUPPLY & MFG., LLCGULF COAST SUPPLY & MFG., LLC14429 SW 2ND PLACE, SUITE G3014429 SW 2ND PLACE, SUITE G30NEWBERRY, FL 32669NEWBERRY, FL 32669352-498-0778 Fax 352-498-7852352-498-0778 Fax 352-498-7852

http://www.gulfcoastsupply.comhttp://www.gulfcoastsupply.com

EXPOSED FASTENER TRIMSEXPOSED FASTENER TRIMS

VALLEYVALLEY

Page 7: CHIMNEY FLASHING - Gulf Coast Supply...chimney flashing cross section nts notes: 1. chimney flashing trim is intended to flash around chimneys and large penetrations. other use may

METAL PANELMETAL PANEL(PBR SHOWN)(PBR SHOWN)

UNDERLAYMENTUNDERLAYMENT

RAFTER OR OTHERRAFTER OR OTHERSTRUCTURAL MEMBERSTRUCTURAL MEMBER

FASCIAFASCIA

ROOF DECKROOF DECK

GABLE RAKE TRIMGABLE RAKE TRIM

EXPOSEDEXPOSEDFASTENER, TYPFASTENER, TYP

GABLE CROSS SECTIONGABLE CROSS SECTIONNTSNTS

NOTES:NOTES:1. GABLE/RAKE TRIM IS USED WHERE THE ROOF TERMINATES AT A PANEL SIDE.1. GABLE/RAKE TRIM IS USED WHERE THE ROOF TERMINATES AT A PANEL SIDE.DIFFERENT STYLES ARE AVAILABLE SUBJECT TO DESIGNER'S SELECTION. OTHERDIFFERENT STYLES ARE AVAILABLE SUBJECT TO DESIGNER'S SELECTION. OTHERUSE MAY BE ACCEPTABLE IF DESIGNER DETERMINES FITNESS OF USE.USE MAY BE ACCEPTABLE IF DESIGNER DETERMINES FITNESS OF USE.2. THIS IS A GENERIC DETAIL FOR GENERAL PURPOSE USE. SPECIAL CONDITIONS2. THIS IS A GENERIC DETAIL FOR GENERAL PURPOSE USE. SPECIAL CONDITIONSMAY REQUIRE ALTERNATIVE DESIGN BY THE INSTALLER OR ARCHITECT/ENGINEER.MAY REQUIRE ALTERNATIVE DESIGN BY THE INSTALLER OR ARCHITECT/ENGINEER.

BUTYLBUTYLTAPETAPE

EF1 DIMENSIONSEF1 DIMENSIONSNTSNTS

NOTES:NOTES:1. USE DIMENSIONS SHOWN. DO NOT SCALE.1. USE DIMENSIONS SHOWN. DO NOT SCALE.2. EF1 IS DESIGNED FOR USE WITH GULFRIB.2. EF1 IS DESIGNED FOR USE WITH GULFRIB.

EF1B DIMENSIONSEF1B DIMENSIONSNTSNTS

NOTES:NOTES:1. USE DIMENSIONS SHOWN. DO NOT SCALE.1. USE DIMENSIONS SHOWN. DO NOT SCALE.2. EF1B S DESIGNED FOR USE WITH GULFRIB AND HAS A2. EF1B S DESIGNED FOR USE WITH GULFRIB AND HAS ALONGER VERTICAL FACE FOR USE OVER BATTENSLONGER VERTICAL FACE FOR USE OVER BATTENS

5"5"

3"3"

3"3"

771616""

3344""

5"5"

3"3"

5"5"

771616""

3344""

EF4 DIMENSIONSEF4 DIMENSIONSNTSNTS

NOTES:NOTES:1. USE DIMENSIONS SHOWN. DO NOT SCALE.1. USE DIMENSIONS SHOWN. DO NOT SCALE.2. EF4 IS DESIGNED FOR USE WITH 5VCRIMP.2. EF4 IS DESIGNED FOR USE WITH 5VCRIMP.

4"4"

3"3"

223344""

771616""

1122""

EF5 DIMENSIONSEF5 DIMENSIONSNTSNTS

NOTES:NOTES:1. USE DIMENSIONS SHOWN. DO NOT SCALE.1. USE DIMENSIONS SHOWN. DO NOT SCALE.2. EF5 IS DESIGNED FOR USE WITH GULFPBR.2. EF5 IS DESIGNED FOR USE WITH GULFPBR.

5"5"

331144""

331122""

771616""

111144""

Details master.dwgDetails master.dwg 2/15/20172/15/2017GULF COAST SUPPLY & MFG., LLCGULF COAST SUPPLY & MFG., LLC14429 SW 2ND PLACE, SUITE G3014429 SW 2ND PLACE, SUITE G30NEWBERRY, FL 32669NEWBERRY, FL 32669352-498-0778 Fax 352-498-7852352-498-0778 Fax 352-498-7852

http://www.gulfcoastsupply.comhttp://www.gulfcoastsupply.com

EXPOSED FASTENER TRIMSEXPOSED FASTENER TRIMS

GABLEGABLE

Page 8: CHIMNEY FLASHING - Gulf Coast Supply...chimney flashing cross section nts notes: 1. chimney flashing trim is intended to flash around chimneys and large penetrations. other use may

METAL PANEL,METAL PANEL,TYPTYP

INSIDE CLOSUREINSIDE CLOSURE

OUTSIDEOUTSIDECLOSURECLOSURE

GAMBREL FLASHING, GF-1GAMBREL FLASHING, GF-1OR SIMILAROR SIMILARINSTALL UNDER TOPINSTALL UNDER TOPPANEL AND OVER BOTTOMPANEL AND OVER BOTTOMPANELPANELROOFROOF

DECKINGDECKING

UNDERLAYMENTUNDERLAYMENT

GAMBREL CROSS SECTIONGAMBREL CROSS SECTIONNTSNTS

NOTES:NOTES:1. GAMBREL FLASHING IS USED AT THE POINT WHERE ROOF SLOPES CHANGE.1. GAMBREL FLASHING IS USED AT THE POINT WHERE ROOF SLOPES CHANGE.DIFFERENT STYLES ARE AVAILABLE SUBJECT TO DESIGNER'S SELECTION. OTHERDIFFERENT STYLES ARE AVAILABLE SUBJECT TO DESIGNER'S SELECTION. OTHERUSE MAY BE ACCEPTABLE IF DESIGNER DETERMINES FITNESS OF USE.USE MAY BE ACCEPTABLE IF DESIGNER DETERMINES FITNESS OF USE.2. THIS IS A GENERIC DETAIL FOR GENERAL PURPOSE USE. SPECIAL CONDITIONS2. THIS IS A GENERIC DETAIL FOR GENERAL PURPOSE USE. SPECIAL CONDITIONSMAY REQUIRE ALTERNATIVE DESIGN BY THE INSTALLER OR ARCHITECT/ENGINEER.MAY REQUIRE ALTERNATIVE DESIGN BY THE INSTALLER OR ARCHITECT/ENGINEER.

GF1 DIMENSIONSGF1 DIMENSIONSNTSNTS

NOTES:NOTES:1. USE DIMENSIONS SHOWN. DO NOT SCALE.1. USE DIMENSIONS SHOWN. DO NOT SCALE.2. GF1 IS SUITABLE FOR USE WITH MOST PANEL PROFILES2. GF1 IS SUITABLE FOR USE WITH MOST PANEL PROFILES

661122""

SPECIFY ROOF PITCHSPECIFY ROOF PITCH

661122""

SPECIFY ROOF PITCHSPECIFY ROOF PITCH

Details master.dwgDetails master.dwg 2/15/20172/15/2017GULF COAST SUPPLY & MFG., LLCGULF COAST SUPPLY & MFG., LLC14429 SW 2ND PLACE, SUITE G3014429 SW 2ND PLACE, SUITE G30NEWBERRY, FL 32669NEWBERRY, FL 32669352-498-0778 Fax 352-498-7852352-498-0778 Fax 352-498-7852

http://www.gulfcoastsupply.comhttp://www.gulfcoastsupply.com

EXPOSED FASTENER TRIMSEXPOSED FASTENER TRIMS

GAMBRELGAMBREL

Page 9: CHIMNEY FLASHING - Gulf Coast Supply...chimney flashing cross section nts notes: 1. chimney flashing trim is intended to flash around chimneys and large penetrations. other use may

METAL PANEL,METAL PANEL,TYPTYP

INSIDE CLOSUREINSIDE CLOSURE

ROOFROOFDECKINGDECKING

TRANSITION CROSS SECTIONTRANSITION CROSS SECTIONNTSNTS

NOTES:NOTES:1. TRANSITION FLASHING IS USED AT THE POINT WHERE ROOF SLOPES CHANGE.1. TRANSITION FLASHING IS USED AT THE POINT WHERE ROOF SLOPES CHANGE.DIFFERENT STYLES ARE AVAILABLE SUBJECT TO DESIGNER'S SELECTION. OTHERDIFFERENT STYLES ARE AVAILABLE SUBJECT TO DESIGNER'S SELECTION. OTHERUSE MAY BE ACCEPTABLE IF DESIGNER DETERMINES FITNESS OF USE.USE MAY BE ACCEPTABLE IF DESIGNER DETERMINES FITNESS OF USE.2. USE OF A LONGER TRANSITION FLASHING IS NECESSARY WHEN THE DIFFERENCE2. USE OF A LONGER TRANSITION FLASHING IS NECESSARY WHEN THE DIFFERENCEBETWEEN SLOPES IS SMALL.BETWEEN SLOPES IS SMALL.3. THIS IS A GENERIC DETAIL FOR GENERAL PURPOSE USE. SPECIAL CONDITIONS3. THIS IS A GENERIC DETAIL FOR GENERAL PURPOSE USE. SPECIAL CONDITIONSMAY REQUIRE ALTERNATIVE DESIGN BY THE INSTALLER OR ARCHITECT/ENGINEER.MAY REQUIRE ALTERNATIVE DESIGN BY THE INSTALLER OR ARCHITECT/ENGINEER.

OUTSIDEOUTSIDECLOSURECLOSURE

TRANSITION FLASHINGTRANSITION FLASHINGINSTALL UNDER TOP PANELINSTALL UNDER TOP PANELAND ABOVE BOTTOM PANELAND ABOVE BOTTOM PANEL

EXPOSEDEXPOSEDFASTENER, TYPFASTENER, TYP

UNDERLAYMENTUNDERLAYMENT

TF1 DIMENSIONSTF1 DIMENSIONSNTSNTS

NOTES:NOTES:1. USE DIMENSIONS SHOWN. DO NOT SCALE.1. USE DIMENSIONS SHOWN. DO NOT SCALE.2. TF1 IS DESIGNED FOR USE WITH GULFRIB, GULFPBR, AND 5VCRIMP.2. TF1 IS DESIGNED FOR USE WITH GULFRIB, GULFPBR, AND 5VCRIMP.

661122""

SPECIFY ROOF PITCHSPECIFY ROOF PITCH

661122""

SPECIFY ROOF PITCHSPECIFY ROOF PITCH

CLOSED HEMCLOSED HEM

Details master.dwgDetails master.dwg 2/15/20172/15/2017GULF COAST SUPPLY & MFG., LLCGULF COAST SUPPLY & MFG., LLC14429 SW 2ND PLACE, SUITE G3014429 SW 2ND PLACE, SUITE G30NEWBERRY, FL 32669NEWBERRY, FL 32669352-498-0778 Fax 352-498-7852352-498-0778 Fax 352-498-7852

http://www.gulfcoastsupply.comhttp://www.gulfcoastsupply.com

EXPOSED FASTENER TRIMSEXPOSED FASTENER TRIMS

TRANSITIONTRANSITION

Page 10: CHIMNEY FLASHING - Gulf Coast Supply...chimney flashing cross section nts notes: 1. chimney flashing trim is intended to flash around chimneys and large penetrations. other use may

PIPE BOOT PLAN VIEWPIPE BOOT PLAN VIEWNTSNTS

NOTES:NOTES:1. PIPE BOOTS ARE DESIGNED TO FLASH AROUND PIPES AND SIMILAR1. PIPE BOOTS ARE DESIGNED TO FLASH AROUND PIPES AND SIMILARPENETRATIONS.PENETRATIONS.2. TYPICAL INSTALLATION PROCESS: CUT OPENING OF PIPE BOOT TO FIT TIGHTLY2. TYPICAL INSTALLATION PROCESS: CUT OPENING OF PIPE BOOT TO FIT TIGHTLYAROUND PIPE. APPLY SEALANT TO BASE OF PIPE BOOT. SLIDE BOOT OVER PIPE.AROUND PIPE. APPLY SEALANT TO BASE OF PIPE BOOT. SLIDE BOOT OVER PIPE.FORM TO ROOF PROFILE. FASTEN PIPE BOOT WITH FASTENERS AT 1-2" OC OR ASFORM TO ROOF PROFILE. FASTEN PIPE BOOT WITH FASTENERS AT 1-2" OC OR ASREQUIRED TO ENSURE TIGHT FIT. APPLY ADDITIONAL SEALANT AS REQUIRED.REQUIRED TO ENSURE TIGHT FIT. APPLY ADDITIONAL SEALANT AS REQUIRED.3. WHENEVER POSSIBLE, PLACE THE PENETRATION IN THE CENTER OF THE PAN. IF3. WHENEVER POSSIBLE, PLACE THE PENETRATION IN THE CENTER OF THE PAN. IFPENETRATION MUST FALL ON PANEL RIB, PIPE BOOT MAY BE INSTALLED ON RIB.PENETRATION MUST FALL ON PANEL RIB, PIPE BOOT MAY BE INSTALLED ON RIB.EXTREME CARE MUST BE EXERCISED TO ENSURE THE BASE OF THE PIPE BOOT HASEXTREME CARE MUST BE EXERCISED TO ENSURE THE BASE OF THE PIPE BOOT HASSUFFICIENT SEALANT, THAT THE BASE IS WELL FORMED TO THE RIB, AND THATSUFFICIENT SEALANT, THAT THE BASE IS WELL FORMED TO THE RIB, AND THATSUFFICIENT FASTENERS ARE USED TO MAINTAIN A WATERTIGHT SEAL. APPLYSUFFICIENT FASTENERS ARE USED TO MAINTAIN A WATERTIGHT SEAL. APPLYADDITIONAL SEALANT AFTER INSTALLATION IF REQUIRED.ADDITIONAL SEALANT AFTER INSTALLATION IF REQUIRED.4. SIZE PIPE BOOT TO FIT THE PIPE/PENETRATION AND PANEL IN USE.4. SIZE PIPE BOOT TO FIT THE PIPE/PENETRATION AND PANEL IN USE.5. THIS IS A GENERIC DETAIL FOR GENERAL PURPOSE USE. SPECIAL CONDITIONS5. THIS IS A GENERIC DETAIL FOR GENERAL PURPOSE USE. SPECIAL CONDITIONSMAY REQUIRE ALTERNATIVE DESIGN BY THE INSTALLER OR ARCHITECT/ENGINEER.MAY REQUIRE ALTERNATIVE DESIGN BY THE INSTALLER OR ARCHITECT/ENGINEER.6. IF CONSTRAINT OF THERMAL MOVEMENT IS A CONCERN FOR LONG PANEL RUNS,6. IF CONSTRAINT OF THERMAL MOVEMENT IS A CONCERN FOR LONG PANEL RUNS,DESIGNER SHOULD CONSIDER INSTALL OPTIONS TO AVOID PINNING ROOF PANEL TODESIGNER SHOULD CONSIDER INSTALL OPTIONS TO AVOID PINNING ROOF PANEL TOTHE ROOF DECK.THE ROOF DECK.

VENT PIPE OR SIMILARVENT PIPE OR SIMILARPENETRATIONPENETRATION

PANEL RIB, TYPPANEL RIB, TYP

FASTENER,FASTENER,TYPTYP

PIPE BOOTPIPE BOOT

SEALANT BETWEEN PANELSEALANT BETWEEN PANELAND BASE OF PIPE BOOTAND BASE OF PIPE BOOT

Details master.dwgDetails master.dwg 7/720177/72017GULF COAST SUPPLY & MFG., LLCGULF COAST SUPPLY & MFG., LLC14429 SW 2ND PLACE, SUITE G3014429 SW 2ND PLACE, SUITE G30NEWBERRY, FL 32669NEWBERRY, FL 32669352-498-0778 Fax 352-498-7852352-498-0778 Fax 352-498-7852

http://www.gulfcoastsupply.comhttp://www.gulfcoastsupply.com

GENERAL TRIMSGENERAL TRIMS