Technical Specifications
• System Function
Automatie, Random Access
STAT sample priority, available for all sample position
Barcode Scanner for sample and reagent
Bi-direction LIS interface (HL7)
Throughput: 360 tests/hour (single and dual reagent)
Up to 540 tests/hour with ISE (K7 Na~ Cl-)
Principle: Colorimetrie, Turbidimetrie
Methodology: End-point, Two-point, Kinetie
Diserepant Value
Single/Duai/Triple/Quadruple reagent
ehemistries
Monoehromatie/Biehromatie
Programming: Opensystem with user defined profiles
and ealeu lation assays
• Sampie/Reagent Handling
2 reagent probes, 1 sample probe
Sampie tray: 100 positions
Reagent tray: 80 refrigerated positions
Refrigeration temperature: 2- 1 OoC
Reagent volume: 20 - 350 iJL, 1 iJL adjustable
R1: 150 - 350 IJL, 1 iJL adjustable
R2: 20- 250 IJL, 1 IJL adjustable
Support R3 and R4
Sampie volume: 2- 45 iJL, 0.1 iJL adjustable
Sampie and Reagent probe:
Collision proteetion , liquid Ievei deteetion
and inventory eheeking
Rayto Rayto reserves the right to change specifications without prior notice. PIN. ENG-Chemray420-20 130726
Chemray 420 Auto Chemistry Analyzer
Probe cleaning:
Automatie washing both interior and
exterior, earryover
-
Chemray 420 Auto Chemistry Analyzer
Reagent System
Multi-functional reagent probe
• lnterior and exterior probe washing
• Liquid Ievei deteetion
• Collision proteetion
• lnventory eheeking
• Reagent volume as low as 201-JI
• Probe depth adjust automatieally
Refrigerated reagent tray
• 80 reagent positions for R1 ,R2,R3,R4
• Compatible with Hitaehi reagent bottles
• 24 hours non-stop eooling with peltier element
• Ready-to-use stable reagent
• Built-in reagent bar eode reader (optional)
Sampie System
Multi-functional sample probe
• lnterior and exterior probe washing
• Liquid Ievei deteetion
• Collision proteetion
• Probe depth adjust automatieally
• Sampie volume as low as 21-JI
Multi-functional sample tray
• 1 00 sample positions
• 7 virtual sample disks
• Support standard tube, primary tube, EP tube
• Automatiedilution of high eoneentration sample
• Automatie rerun
• Built-in sample bar eode reader (optional)
Optical System
• Unique water eooling system for light souree
• Maximum stabilized optieal system
• Sealed optieal system to prevent any dust and disturbanee
• Reversed opties, grating photometry
• Maintenanee free
ISE module
• Optional seleetion of K+ , Na~CI-
• Throughput: up to 270 tests per hour
• 6 months shelf life
Operation System
·!~l"'' .. ! ~-o--·~·-····---:::o:.:.:~::···--~ .. =·-·-·-_ ___I Reaction Curve
• Substrate exhaust Iimit deteetion
• Equilibrium point auto seareh
-I· QC Graph
• QC type: real-time QC, daily QC, day to day QC
• Control rule: multi-rules QC, intelligent QC alarm
Calibration Setting
• Refitting : fitting different types of ealibration
eurve with a eertain standard data, thus ehoosing
the best ealibration eurve
Reaction System
Reaction tray
• Optimized test sequenee to reduee earryover
• Total reaetion volume as low as 1501-JI
• Contains 100 reaetion euvettes
• Real direet heating
• Real-time display of reaetion tray temperature
Unique washing station
• High precision washing liquid control to guarantee washing function
• Washing solution pre-heating to prevent any earryover
• Maintain ideal temperature for testing
• 8 steps auto-washing
• Separate drainage for high and low eoneentration waste
• Ceramie syringe for auto wahsing system, high aeeuraey
High performance mixer design
• Two independent mixers
• Optimized homogenization in minimum time
• Standardized mixing procedures
• Function immediately after sample and reagent pipetted in
Parametersetting
• Different Ieveis of user permission
• Different reference range according to gender and age
• Calculated items available
• Manual items input available
• Automatie rerun
• 3-150 times auto dilution
Statistics
• Caleulate the mean value, standard deviation
and eoeffieient of variation
• Statistics of reagent usage
• Statistics of test volume
·- .i\.-
f -· : __ ---l . ~ --~- ~-~~ ..