Charmonium Spectroscopy atPANDA

39
Charmonium Spectroscopy atPANDA Diego Bettoni INFN, Ferrara, Italy for the PANDA Collaboration Mainz, Germany, 19 November 2009

description

Charmonium Spectroscopy atPANDA. Diego Bettoni INFN, Ferrara, Italy for the  PANDA Collaboration Mainz, Germany, 19 November 2009 . Outline. Introduction HESR and  PANDA Experimental Method The scientific program of PANDA Charmonium at  PANDA Charmonium below threshold  DD - PowerPoint PPT Presentation

Transcript of Charmonium Spectroscopy atPANDA

Page 1: Charmonium Spectroscopy  atPANDA

Charmonium Spectroscopy atPANDA

Diego BettoniINFN, Ferrara, Italy

for the PANDA Collaboration

Mainz, Germany, 19 November 2009

Page 2: Charmonium Spectroscopy  atPANDA

Outline

• Introduction– HESR and PANDA– Experimental Method– The scientific program ofPANDA

• Charmonium atPANDA– Charmonium below threshold– DD– Charmonium hybrids– Charmonium in nuclei

• Summary

Page 3: Charmonium Spectroscopy  atPANDA

PANDA at FAIR 3D. Bettoni

High luminosity mode

High resolution mode

• dp/p ~ 10-5 (electron cooling)• Lumin. = 1031 cm-2 s-1

• Lumin. = 2 x 1032 cm-2 s-1 • dp/p ~ 10-4 (stochastic cooling)

• Production rate 2x107/sec

• Pbeam = 1 - 15 GeV/c

• Nstored = 5x1010 p

• Internal Target

_

High-Energy Storage Ring

Page 4: Charmonium Spectroscopy  atPANDA

Diego Bettoni Charmonium 4

pp AnnihilationIn pp collisions the coherent annihilation of the 3 quarks inthe p with the 3 antiquarks in thep makes it possible to form directly states with all non-exotic quantum numbers.

The measurement of masses andwidths is very accurate because itdepends only on the beam parameters,not on the experimental detectorresolution, which determines only thesensitivity to a given final state.

Page 5: Charmonium Spectroscopy  atPANDA

Diego Bettoni Charmonium 5

Experimental Method

4/412

22

2

2RR

RoutinBW ME

BBk

J-

The cross section for the process: pp R final stateis given by the Breit-Wigner formula:

The production rate is a convolution of theBW cross section and the beam energy distribution function f(E,E):

bBW EEEdEfL )(),(0

The resonance mass MR, total width R and product of branching ratiosinto the initial and final state BinBout can be extracted by measuring theformation rate for that resonance as a function of the cm energy E.

Page 6: Charmonium Spectroscopy  atPANDA

PANDA at FAIR 6D. Bettoni

Example: c1 and c2 scans in Fermilab E835

1

2

Page 7: Charmonium Spectroscopy  atPANDA

PANDA at FAIR 7D. Bettoni

PANDA Detector

See presentation by Lars Schmitt

Detector Requirements

•(Nearly) 4 solid angle coverage (partial wave analysis)•High-rate capability (2×107 annihilations/s)•Good PID (, e, µ, , K, p)•Momentum resolution ( 1 %)•Vertex reconstruction for D, K0

s, •Efficient trigger•Modular design•Pointlike interaction region•Lepton identification•Excellent calorimetry

• Energy resolution• Sensitivity to low-energy

photons

Page 8: Charmonium Spectroscopy  atPANDA

Recent Activities• Electromagnetic Calorimeter

TDR written• Crystals funded• Dipole magnet and forward

Čerenkov funded• Magnet TDR written• Tracking TDR in progress• First version of PANDA

Physics Book completed. ArXiV:0903.3905.

Page 9: Charmonium Spectroscopy  atPANDA

PANDA at FAIR 9D. Bettoni

PANDA Physics Program

• QCD BOUND STATES– CHARMONIUM– GLUONIC EXCITATIONS– HEAVY-LIGHT SYSTEMS – STRANGE AND CHARMED BARYONS

• NON PERTURBATIVE QCD DYNAMICS• HADRONS IN THE NUCLEAR MEDIUM• NUCLEON STRUCTURE

– GENERALIZED DISTRIBUTION AMPLITUDES (GDA)

– DRELL-YAN– ELECTROMAGNETIC FORM FACTORS

• ELECTROWEAK PHYSICS

Page 10: Charmonium Spectroscopy  atPANDA

Charmonium Spectroscopy

Main issues•All 8 states below threshold observed, some (precision) measurements still missing:

• hc (e.g. width)• c(1S)• c(2S) (small splitting from (2S))

•The region above open charm threshold must be explored in great detail:

• find missing D states• explain newly discovered states

(cc or other)• confirm vector states seen in R

See presentation by Simon Eidelmann

Page 11: Charmonium Spectroscopy  atPANDA

Charmonium at PANDA

• At 21032cm-2s-1 accumulate 8 pb-1/day (assuming 50 % overall efficiency) 104107 (cc) states/day.

• Total integrated luminosity 1.5 fb-1/year (at 21032cm-2s-1, assuming 6 months/year data taking).

• Improvements with respect to Fermilab E760/E835:– Up to ten times higher instantaneous luminosity.– Better beam momentum resolution p/p = 10-5 (GSI) vs 210-4 (FNAL)– Better detector (higher angular coverage, magnetic field, ability to detect

hadronic decay modes).• Fine scans to measure masses to 100 KeV, widths to 10 %.• Explore entire region below and above open charm threshold.• Decay channels

– J/+X , J/ e+e-, J/ m+m-

– – hadrons– DD

•Precision measurement of known states•Find missing states (e.g. D states)•Understand newly discovered states

Get a complete picture of the dynamics ofthe cc system.

Page 12: Charmonium Spectroscopy  atPANDA

Hadrons in Nuclear Matter

•Partial restoration of chiral symmetry in nuclear matter– Light quarks are sensitive to quark condensate

•Evidence for mass changes of pions and kaons has been deduced previously:– deeply bound pionic atoms– (anti)kaon yield and phase space distribution

•(cc) states are sensitive to gluon condensate– small (5-10 MeV/c2) in medium modifications for

low-lying (cc) (J/, c)– significant mass shifts for excited states: 40, 100, 140 MeV/c2 for cJ, ’, (3770) resp.

•D mesons are the QCD analog of the H-atom.– chiral symmetry to be studied on a single light

quark– theoretical calculations disagree in size and sign

of mass shift (50 MeV/c2 attractive – 160 MeV/c2 repulsive)

vacuum nuclear medium

K

25 MeV

100 MeV

K+

K-

-

Hayaski, PLB 487 (2000) 96Morath, Lee, Weise, priv. Comm.

D-

50 MeV

D

D+

Page 13: Charmonium Spectroscopy  atPANDA

Charmonium in Nuclei

• Measure J/ and D production cross section in p annihilation on a series of nuclear targets.

• J/ nucleus dissociation cross section• Lowering of the D+D- mass would allow

charmonium states to decay into this channel, thus resulting in a dramatic increase of width (1D) 20 MeV 40 MeV

(2S) .28 MeV 2.7 MeV Study relative changes of yield and

width of the charmonium states. • In medium mass reconstructed from

dilepton (cc) or hadronic decays (D)

Page 14: Charmonium Spectroscopy  atPANDA

Monte Carlo Simulations

• Event generators with accurate decay models for the individual physics channels as well as for the relevant background channels (e.g. Dual Parton Model, UrQMD, ...).

• Particle tracking through the complete PANDA detector by using the GEANT4 transport code.

• Digitization which models the signals of the individual detectors and their processing in the frontend electronics.

• Reconstruction and identification of charged and neutral particles, providing lists of particle candidates for the physics analysis.Kalman Filter for charged particle tracking.

• High-level analysis tools which allow to make use of vertex and kinematical fits and to reconstruct decay trees.

Page 15: Charmonium Spectroscopy  atPANDA

PANDA at FAIR 15D. Bettoni

Charmonium Decays to J/

pp cc J/ + X, J/ e+e-, (m+m-)• Tagged by lepton pair with invariant mass equal to M(J/ ).• Main background source: misidentified +- pairs.• Electron analysis:

– two electron candidates: one Loose one Tight.– kinematic fit to J/ hypothesis with vertex constraint.– P(fit) > 0.001.

• Additional cuts for exclusive final states:– pp J/+- – pp J/00

– pp c1,c2J/– pp J/– pp J/

MeVs 4260

Page 16: Charmonium Spectroscopy  atPANDA

PANDA at FAIR 16D. Bettoni

Main background process:

pp + - + -

Estimated background cross section < 10 pb

pp J/ +- e+e- +-

•J/ selection•two pion candidates (VeryLoose)•vertex fit to J/+-

222

mmPHSP

dmdN -

Page 17: Charmonium Spectroscopy  atPANDA

PANDA at FAIR 17D. Bettoni

Main background process:

pp + - 0 0

Estimated S/B 25

pp J/ 00 e+e- 00

Page 18: Charmonium Spectroscopy  atPANDA

PANDA at FAIR 18D. Bettoni

hc c 3

nbeV

MeVE

ppp c3310

503

B

•Pair 2 s to form c mass (12).

•4C fit to hc candidate.•N=3.•CL (4C fit) > 10-4

:

•0.4 GeV < E < 0.6 GeV.•|cos| < 0.6 .•M(13),M(23) > 1 GeV.

Page 19: Charmonium Spectroscopy  atPANDA

PANDA at FAIR 19D. Bettoni

hc c 3

In high-luminosity mode(L = 21032cm-2s-1) expect20 signal events/day.

signal efficiency 8.2 %

Page 20: Charmonium Spectroscopy  atPANDA

hc c 4K

In high-luminosity mode(L = 21032cm-2s-1) expect92 signal events/day.

345 nb60 nb< 3 nb30 mb

DPM estimate

• candidates: K pairs in appropriate mass window.•4C fit to beam-momentum•CL (4C) > 0.05•c invariant mass [2.9, 3.06] GeV .•E [0.4, 0.6] GeV • mass [0.99, 1.05] GeV •no 0 in event

signal efficiency 24 %

Page 21: Charmonium Spectroscopy  atPANDA

PANDA at FAIR 21D. Bettoni

Sensitivity to hc Width Measurement

signal efficiency =0.24

each point correspondsto 5 days of data taking

Page 22: Charmonium Spectroscopy  atPANDA

pp DD

•Charmonium states above open charm threshold•Charm spectroscopy•Search for hybrids decaying to DD•Rare D decays (and CP violation) Main issue: separation of charm signal from large hadronic background

--

--

KDDDDDpp

KDDDpp00***

4040

3770

s

s

Cross section estimates: Breit-Wigner, with pp BR scaled from

nbDDpp

nbDDpp

9.04040

8.23770**

-

-

See also presentation by Tobias Stockmanns

Page 23: Charmonium Spectroscopy  atPANDA

Event Selection

• Loose mass window cut before vertex fitting m = 0.3 GeV/c2.• Minimum 6 charged tracks.• All decay particles must form a common vertex.• 4C kinematic fit to constrain beam energy and momentum:

CL > 510-2.• K/ selection Loose (LH > 0.3).• Only one combination per event.

Page 24: Charmonium Spectroscopy  atPANDA

Signal Efficiency

- DDpp - ** DDpp

Dm *Dm 0Dm

overall efficiency(signal) = 40 %

overall efficiency (signal) = 27.4 % (4C fit)overall efficiency (signal) = 24.0 % (5C fit)

after 5C fit (D0 mass constraint)

Page 25: Charmonium Spectroscopy  atPANDA

Background Studies

Page 26: Charmonium Spectroscopy  atPANDA

2K4 Background

pT vs pL signal pT vs pL 2K4 background

Two-dimensional cut onD momentum reduces2K4 background byfactor 26.

Cut on z of D decay vertex:z > 0.088 cm S/B = 1 (signal) = 7.8 %

For the D*+D*- channel the analysis givesS/B = 1/3. An additional cut on the z of the D0 decay vertex gives S/B=3/2, bringingthe signal efficiency from 24 % to 12.7 %.

Page 27: Charmonium Spectroscopy  atPANDA

Non Strange Background

Page 28: Charmonium Spectroscopy  atPANDA

Charmonium Hybrids Simulation

• Charmonium hybrid ground state– expected to be spin-exotic JPC = 1-+

– mass prediction: 4.1 – 4.4 GeV/c2

• In this analysis:– assume M = 4.29 MeV/c2, = 20 MeV– produced inpp with recoil particle at 15 GeV– decay modes

– assume signal cross section to be of the same order of magnitude as

1~

cpp

0*01

0011

~~ DDccc

GeVspbSpp 38.58332

Page 29: Charmonium Spectroscopy  atPANDA
Page 30: Charmonium Spectroscopy  atPANDA

Reconstruction efficiency6.83 % for J/ e+e-

MeV

FWHMwidthsignalc

30

~1

0011

~16.0 ccN BExpected events per day

c100 channel

Page 31: Charmonium Spectroscopy  atPANDA

c100 background studies

B

ccSR

0011

~

B

0011

~ ccSB BO

S/N 250-10100 R depending on J/ background channelvery low background contamination expected if

Page 32: Charmonium Spectroscopy  atPANDA

D0D0* Decay mode

Signal reconstruction efficiency 5.17 %

background rejection > 1.6105

Page 33: Charmonium Spectroscopy  atPANDA

Y(3940) J/ e+e-+-0

Page 34: Charmonium Spectroscopy  atPANDA

Reconstruction efficiency14.7 % for J/ e+e-

Page 35: Charmonium Spectroscopy  atPANDA

J/ background studies

Page 36: Charmonium Spectroscopy  atPANDA

pA J/X

Page 37: Charmonium Spectroscopy  atPANDA
Page 38: Charmonium Spectroscopy  atPANDA

Required rejection factor of theorder of 106 achieved !!!

Page 39: Charmonium Spectroscopy  atPANDA

Summary and Outlook

The HESR at the GSI FAIR facility will deliverp beams of unprecedented quality with momenta up to 15 GeV/c (√s 5.5 GeV). This will allow PANDA to carry out the following measurements:SPECTROSCOPY• High-resolution charmonium spectroscopy in formation experiments• Study of gluonic excitations (hybrids and glueballs) and other exotica (e.g. multiquark)• Study of hadrons in nuclear matter• Open charm physics• Hypernuclear physicsNUCLEON STRUCTURE• Proton Timelike Form Factors• Crossed-Channel Compton Scattering• Drell-Yan The performance of the detector and the sensitivity to the various physics channels havebeen estimated reliably by means of detailed Monte Carlo simulations:• Acceptance• Resolution• Signal/BackgroundThe simulations show that the final states of interest can be detected with good efficiency and that the background situation is under control.