GD-ID021 Lift C02 Lift C01 Lift 04 access at 79.24 ALLOW FOR 50MM TENANT FINISHES IN ALL RETAIL UNITS 79.000 FFL 78.950 SFL FIRE CURTAIN Lift 04 access at 81.13 SERVICE ACCESS BOH A1 A1 C1 C1 C3 D1 D2 D3 D4 D5 D5 D6 D6 E1 E1 E3 E4 E5 E5 F1 F2 F2 F3 F4 F5 F6 F7 F8 F9 Core C01 Core C02 79.240 FFL 79.240 FFL 79.190 SFL 81.130 FFL 81.080 SFL C2 H H B1 B1 G G A2 B2 GD-ID009 FD60S VP GD-ID011 FD60S GD-ID022 FD60 GD-ID020 FD60S GD-ID010 FD60S VP GD-ID008 FD30S VP GD-ID013 FD60S GD-ID012 FD60S GD-ID004 GD-ID016 FD60S VP GD-ID005 GD-ID014 FD60 GD-OF001 GD-ID015 FD30S VP GD-CW004 GD-CW001 GD-ID007 FD60S VP Sub Station 78.440 FFL 78.390 SFL 80.890 80.550 78.920 78.130 STAIR C01 STAIR C02 KEY CAT B - RETAIL SHOPFRONT, PART OF TENANT FITOUT PACKAGE +80.973 +80.796 +80.645 +80.496 +80.377 +80.212 +80.116 +80.045 +79.897 +79.657 +79.410 +79.204 +78.988 +78.822 +78.641 +78.500 +78.408 +78.275 +78.092 +78.008 +77.925 +77.851 +77.822 +77.843 +77.881 +77.915 +77.944 +78.011 +78.074 +78.149 +78.208 +78.285 +78.365 +78.400 +78.477 +78.583 +78.701 +78.738 +78.803 +78.821 +78.897 +78.958 +79.064 +79.184 +79.318 +79.498 +79.837 +80.009 +80.193 +80.310 +80.431 +80.474 +80.528 +80.569 +80.751 +80.856 +80.958 +81.040 +81.130 +81.168 +81.186 +81.114 Basement exhaust and lobby vent Tenant risers Tenant stair - location TBC GD-ID019 FD60S G03 RETAIL G02 RETAIL G01 RETAIL G05 RETAIL G04 RETAIL GD-ID006 FD60S VP 78.430 GD-CW006 GD-CW004 GD-CW008 CAMBRIDGE STREET PIN STONE ST R EET CHARLES STREET Riser 10 Riser 09 Riser 01 Riser 08 Riser 02 Riser 06 Riser 05 Riser 04 DIS WC Toilet Break room Reception OFFICE Columns, beams and slab edge location is subject to detail survey of retained existing facade. Columns, beams and slab edge location is subject to detail survey of retained existing facade. 78.430 FFL 78.390 SFL ALLOW FOR 50MM TENANT FINISHES IN ALL RETAIL UNITS 80.550 FFL 80.500 SFL Net Lettable Area 1475ft² (137m²) Net Lettable Area 1384ft² (129m²) Net Lettable Area 1019ft² (95m²) Net Lettable Area 1528 ft² (142m²) Net Lettable Area 1679 ft² (156m²) GD-ID025 GD-ID024 GD-ID023 E2 GD-ID018 FD60S G1 G2 GD-CW003 GD-CW007 GD-CW003 GD-CW002 GD-OF002 PLEASE NOTE THAT THE REVOLVING DOOR OPENING SHOULD BE PARALLEL TO THE CURTAIN WALL SCREEN. PLEASE NOTE THAT IT IS ALSO SHOWN WITH THE OUT OF HOURS, IN ITS CLOSED POSITION. For correct configuration of walls and doorways in this area, please refer to details 2659. Checked By Revision Date Rev. Client Project Drawing Title Project Number Suitability Checked by Drawn by Scale @A1 Date Revision File Identifier Purpose of Issue Dimensions to be verified on site. Use figured dimensions only. Do not work from reduced scale drawings. Please refer to scale and sheet size as indicated. This drawing is the property of LEONARD DESIGN ARCHITECTS LTD. Copyright is reserved by them and the drawing is issued on the condition that it is not copied, reproduced, retained or disclosed to any unauthorised person without the prior consent in writing of Leonard Design Architects Ltd. All rights reserved. DO NOT SCALE Project Status leonard design architects 4th floor, Albion House 5-13 Canal Street Nottingham. NG1 7EG. United Kingdom t. +44 (0) 115 945 0080 e. [email protected] Key Plan Orientation CONSTRUCTION Notes: • All interfaces with retained and/or existing site conditions are based upon existing available survey information. LDA bear no responsibility for the accuracy of this information; contractor to provide all necessary survey and/or check dims as required to ensure compliance with design intent • Basement perimeter wall setting out is indictive, subject to receipt of accurate survey information in connection with retained elements, and agreed build-up zone for proposed internal linings by specialist ground work sub-contractor • All drawings and performance standards are subject to specialist consultant review and co-ordination (M&E, Acoustics and Fire) • All structural information is indicative, refer to Structural Engineers’ details and specification for all specific structural information • All M&E information is indicative, Refer to M&E Subcontractors’ details and specification for details for all specific services information • All setting out and detailing is subject to ongoing detailed design development with suppliers and specialist sub-contractors for all key packages (Brickwork, Glazing, cladding, Insulation, Internal partitions etc.) • All selected materials are subject to local statutory approvals (Planning and fire) • All external works are indicative, Refer to Landscape Architect, Civil engineer and highways details and specifications for details for all specific services information • All proposed works in connection with the retained elevation to Pinstone Street (including the returns) subject to receipt of accurate survey information to confirm the condition and setting out of the inner retained surface finish, and accurate setting out of all existing structural openings; This information also required in order to schedule proposed replacement windows. • Columns, beams and slab edge location, is subject to detail survey of retained existing facade. 1 : 100 C07 Block C - Heart of City 2 - Sheffield KG SB 16/07/18 GA Ground Floor Plan HOC HOC - LDA - ZZ - 00 - DR - A - 2001 A1 CONSTRUCTION 1 : 100 1 L0 Proposed GA Ground Floor Plan 0m 1:100 1m 2m 4m 6m 8m 10m 0mm 1:1 10mm 20mm 40mm 60mm 80mm 100mm P01 21.08.18 Drawings issued for information LDA SB P02 11.10.18 Issued for Planning LDA SB P03 26.10.18 Drawings issued for Tender JP SB P04 09.11.18 Tender Issue LDA SB P05 15.04.19 Stair cores refined LDA JPS P06 07.05.19 Design development MD GT P07 23.05.19 Contractor Design Issue MD GT P08 07.06.19 Grid alinged to S.E. grids; door, wall and window tags added MD SB P09 05.08.19 Levels amended, stairs amended, retail lift under reveiw MD P010 23.08.19 Drawings updated for CP issue MN SB P011 09.10.19 Level corrected MD SB P012 14.11.19 Wall types rationalised; Wall referances amended GT SB P013 20.12.19 Preliminary issue for comments MD SB C01 19.03.20 Substation changes to NPG drawing MD GT C02 20.03.20 Wall moved MD GT C03 19.05.20 Net lettable areas indicated to retail areas AG SB C04 20.05.20 Net lettable areas indicated to retail areas AG SB C05 26.06.20 Door added MD ZM C06 04.12.20 Minor updates MN ZM C07 15.12.20 Updated NIA MN SB

Transcript of CHARLES STREET - s3-eu-west-1.amazonaws.com

Page 1: CHARLES STREET - s3-eu-west-1.amazonaws.com

GD-ID021

Lift C02

Lift C01

Lift 04 access at 79.24

ALLOW FOR 50MM TENANT FINISHES IN ALL RETAIL UNITS

79.000 FFL78.950 SFL

FIRE CURTAIN

Lift 04 access at 81.13

SE

RVI

CE

AC

CE

SS

BO

H

A1

A1

C1

C1

C3

D1

D2

D3

D4

D5

D5

D6

D6

E1E1

E3

E4

E5E5

F1

F2

F2F3

F4

F5

F6

F7

F8

F9

Core C01

Core C02

79.240 FFL

79.240 FFL79.190 SFL

81.130 FFL81.080 SFL

C2

H

H

B1

B1

G

G

A2

B2

GD-ID009FD60S VP

GD-ID011FD60S

GD-ID022FD60

GD-ID020FD60S

GD-ID010FD60S VP

GD-ID008FD30S VP

GD-ID013FD60S

GD-ID012FD60S

GD-ID004

GD-ID016FD60S VP

GD-ID005

GD-ID014FD60

GD-OF001

GD-ID015FD30S VP

GD-CW004

GD-CW001

GD-ID007FD60S VP

Sub Station

78.440 FFL78.390 SFL

80.890

80.550

78.920

78.130

STAIR C01

STAIR C02

KEY

CAT B - RETAIL SHOPFRONT, PART OF TENANT FITOUT PACKAGE

+80.973

+80.796

+80.645

+80.496

+80.377

+80.212

+80.116

+80.045

+79.897

+79.657

+79.410

+79.204

+78.988

+78.822

+78.641

+78.500

+78.408

+78.275

+78.092

+78.008

+77.925

+77.851

+77.822

+77.843

+77.881+77.915

+77.944

+78.011

+78.074

+78.149

+78.208

+78.285

+78.365

+78.400+78.477

+78.583

+78.701

+78.738+78.803

+78.821

+78.897

+78.958

+79.064

+79.184

+79.318

+79.498

+79.837

+80.009

+80.193

+80.310

+80.431

+80.474

+80.528

+80.569

+80.751

+80.856

+80.958

+81.040

+81.130

+81.168

+81.186

+81.114

Basement exhaust and lobby vent

Tena

nt ri

sersTenant stair -

location TBC

GD-ID019FD60S

G03RETAIL

G02RETAIL

G01RETAIL

G05RETAIL

G04RETAIL

GD-ID006FD60S VP

78.430

GD-CW006

GD-CW004

GD-CW008

CAMBRIDGE STREET

PINSTONE STREET

CH

AR

LES

STR

EE

T

Riser 10

Riser 09

Riser 01

Riser 08

Riser 02

Riser 06

Riser 05

Riser 04

DIS WC

Toilet

Break room

ReceptionOFFICE

Columns, beams and slab edge location is subject to detail survey of retained existing facade.

Columns, beams and slab edge location is subject to detail survey of retained existing facade.

78.430 FFL78.390 SFL

ALLOW FOR 50MM TENANT FINISHES IN ALL RETAIL UNITS

80.550 FFL80.500 SFL

Net Lettable Area 1475ft² (137m²)

Net Lettable Area 1384ft² (129m²)

Net Lettable Area 1019ft² (95m²)

Net Lettable Area 1528 ft² (142m²)

Net Lettable Area 1679 ft² (156m²)

GD-ID025

GD-ID024

GD-ID023

E2

GD-ID018FD60S

G1

G2

GD-CW003

GD-CW007

GD-CW003

GD-CW002

GD-OF002

PLEASE NOTE THAT THE REVOLVING DOOR OPENING SHOULD BE PARALLEL TO THE CURTAIN WALL SCREEN.PLEASE NOTE THAT IT IS ALSO SHOWN WITH THE OUT OF HOURS, IN ITS CLOSED POSITION.

For correct configuration of walls and doorways in this area, please refer to details 2659.

CheckedByRevisionDateRev.

Client

Project

Drawing Title

Project Number Suitability

Checked byDrawn by

Scale @A1 Date

RevisionFile Identifier

Purpose of Issue

Dimensions to be verified on site.Use figured dimensions only. Do not work from reduced scale drawings. Please refer to scale and sheet size as indicated.

This drawing is the property of LEONARD DESIGN ARCHITECTS LTD.

Copyright is reserved by them and the drawing is issued on the condition that it is not copied, reproduced, retained or disclosed to any unauthorised person without the prior consent in writing of Leonard Design Architects Ltd. All rights reserved.

DO NOT SCALE

Project Status

leonard design architects4th floor, Albion House

5-13 Canal StreetNottingham. NG1 7EG. United Kingdom

t. +44 (0) 115 945 0080e. [email protected]

Key Plan

Orientation

CONSTRUCTION

Notes:

• All interfaces with retained and/or existing site conditions are based upon existing available survey information. LDA bear no responsibility for the accuracy of this information; contractor to provide all necessary survey and/or check dims as required to ensure compliance with design intent

• Basement perimeter wall setting out is indictive, subject to receipt of accurate survey information in connection with retained elements, and agreed build-up zone for proposed internal linings by specialist ground work sub-contractor

• All drawings and performance standards are subject to specialist consultant review and co-ordination (M&E, Acoustics and Fire)

• All structural information is indicative, refer to Structural Engineers’ details and specification for all specific structural information

• All M&E information is indicative, Refer to M&E Subcontractors’ details and specification for details for all specific services information

• All setting out and detailing is subject to ongoing detailed design development with suppliers and specialist sub-contractors for all key packages (Brickwork, Glazing, cladding, Insulation, Internal partitions etc.)

• All selected materials are subject to local statutory approvals (Planning and fire)

• All external works are indicative, Refer to Landscape Architect, Civil engineer and highways details and specifications for details for all specific services information

• All proposed works in connection with the retained elevation to Pinstone Street (including the returns) subject to receipt of accurate survey information to confirm the condition and setting out of the inner retained surface finish, and accurate setting out of all existing structural openings; This information also required in order to schedule proposed replacement windows.

• Columns, beams and slab edge location, is subject to detail survey of retained existing facade.

1 : 100

C07

Block C - Heart of City 2 -Sheffield

KG SB

16/07/18

GA Ground Floor Plan

HOC

HOC - LDA - ZZ - 00 - DR - A - 2001

A1

CONSTRUCTION1 : 1001 L0 Proposed GA Ground Floor Plan

0m1:100 1m 2m 4m 6m 8m 10m

0mm1:1 10mm 20mm 40mm 60mm 80mm 100mm

P01 21.08.18 Drawings issued for information LDA SBP02 11.10.18 Issued for Planning LDA SBP03 26.10.18 Drawings issued for Tender JP SBP04 09.11.18 Tender Issue LDA SBP05 15.04.19 Stair cores refined LDA JPSP06 07.05.19 Design development MD GTP07 23.05.19 Contractor Design Issue MD GT

P08 07.06.19 Grid alinged to S.E. grids; door,wall and window tags added

MD SB

P09 05.08.19 Levels amended, stairs amended,retail lift under reveiw

MDP010 23.08.19 Drawings updated for CP issue MN SBP011 09.10.19 Level corrected MD SB

P012 14.11.19 Wall types rationalised; Wallreferances amended

GT SBP013 20.12.19 Preliminary issue for comments MD SB

C01 19.03.20 Substation changes to NPGdrawing

MD GTC02 20.03.20 Wall moved MD GT

C03 19.05.20 Net lettable areas indicated toretail areas

AG SB

C04 20.05.20 Net lettable areas indicated toretail areas

AG SBC05 26.06.20 Door added MD ZMC06 04.12.20 Minor updates MN ZMC07 15.12.20 Updated NIA MN SB

Page 2: CHARLES STREET - s3-eu-west-1.amazonaws.com

L01OFFICE

L01 Lobby

VOID

Core C02

Core C01

10-ID007

VOID

Lift C01

Lift C02

L01RETAIL

A1

A1

B3

C1

C1

C3

D1

D2

D3

D4

D5

D6

E1

E3

E4

E5

F1F2

F3

F4

F5

F6

F7

F8

F9

83.430 FFL83.330 SFL

83.430 FFL83.280 SFL

82.600 FFL82.550 SFL

Cambridge St

Pinstone St

Cha

rles

St

C2

H

B1

B1

G

A2

B2

10-ID101FD30S VP

10-ID002FD60S

10-ID102FD60S VP

10-ID003FD60

10-ID011FD60

10-ID012FD60

10-ID013FD60S VP

10-ID001FD30S VP

10-ID103FD60S VP

10-ID104FD30S VP

10-ID018FD60

10-ID015FD60

10-ID016FD60

10-ID017FD60

83.430

STAIR C01

STAIR C02

Knock out floor for future

tenant lift

Tenant stair -location TBC

Tena

nt ri

sers

86.039

83.430

87.180

LIFT C04

83.430

KEY

CAT B - RETAIL SHOPFRONT, PART OF TENANT FITOUT PACKAGE

10-ID010FD60

10-ID00610-ID00510-ID004

Riser 10

Riser 09

Riser 01

Riser 08

Riser 06

Riser 05

Riser 04

Riser 02

Void

Sub Station

L01OFFICE AMENITIES

DIS WC

Columns, beams and slab edge location is subject to detail survey of retained existing facade.

Columns, beams and slab edge location is subject to detail survey of retained existing facade.

Net Lettable Area 926ft² (86m²)

E2

G1

G2

Net Lettable Area 5038ft² (468m²)

CheckedByRevisionDateRev.

Client

Project

Drawing Title

Project Number Suitability

Checked byDrawn by

Scale @A1 Date

RevisionFile Identifier

Purpose of Issue

Dimensions to be verified on site.Use figured dimensions only. Do not work from reduced scale drawings. Please refer to scale and sheet size as indicated.

This drawing is the property of LEONARD DESIGN ARCHITECTS LTD.

Copyright is reserved by them and the drawing is issued on the condition that it is not copied, reproduced, retained or disclosed to any unauthorised person without the prior consent in writing of Leonard Design Architects Ltd. All rights reserved.

DO NOT SCALE

Project Status

leonard design architects4th floor, Albion House

5-13 Canal StreetNottingham. NG1 7EG. United Kingdom

t. +44 (0) 115 945 0080e. [email protected]

Key Plan

Orientation

CONSTRUCTION

Notes:

• All interfaces with retained and/or existing site conditions are based upon existing available survey information. LDA bear no responsibility for the accuracy of this information; contractor to provide all necessary survey and/or check dims as required to ensure compliance with design intent

• Basement perimeter wall setting out is indictive, subject to receipt of accurate survey information in connection with retained elements, and agreed build-up zone for proposed internal linings by specialist ground work sub-contractor

• All drawings and performance standards are subject to specialist consultant review and co-ordination (M&E, Acoustics and Fire)

• All structural information is indicative, refer to Structural Engineers’ details and specification for all specific structural information

• All M&E information is indicative, Refer to M&E Subcontractors’ details and specification for details for all specific services information

• All setting out and detailing is subject to ongoing detailed design development with suppliers and specialist sub-contractors for all key packages (Brickwork, Glazing, cladding, Insulation, Internal partitions etc.)

• All selected materials are subject to local statutory approvals (Planning and fire)

• All external works are indicative, Refer to Landscape Architect, Civil engineer and highways details and specifications for details for all specific services information

• All proposed works in connection with the retained elevation to Pinstone Street (including the returns) subject to receipt of accurate survey information to confirm the condition and setting out of the inner retained surface finish, and accurate setting out of all existing structural openings; This information also required in order to schedule proposed replacement windows.

• Columns, beams and slab edge location, is subject to detail survey of retained existing facade.

1 : 100

C05

Block C - Heart of City 2 -Sheffield

KG SB

16/07/18

GA First Floor Plan

HOC

HOC - LDA - ZZ - 10 - DR - A - 2002

A1

CONSTRUCTION1 : 1001 L1 Proposed GA First Floor Plan

0m1:100 1m 2m 4m 6m 8m 10m

0mm1:1 10mm 20mm 40mm 60mm 80mm 100mm

P01 21.08.18 Drawings issued for information LDA SBP02 11.10.18 Issued for Planning LDA SBP03 26.10.18 Drawings issued for Tender JP SBP04 09.11.18 Tender Issue LDA SBP05 15.04.19 Stair cores refined LDA JPSP06 07.05.19 Design development MD GTP07 23.05.19 Contractor Design Issue MD GT

P08 07.06.19 Grid alinged to S.E. grids; door,wall and window tags added

MD SB

P09 05.08.19 Insulation to external walls, doorratings, retail lift under review

MDP010 23.08.19 Drawings updated for CP issue MN SB

P011 14.11.19 Wall types rationalised; Wallreferances amended

GT SBP012 20.12.19 Preliminary issue for comments MD SB

C01 19.03.20 Substation changes to NPGdrawing

MD GTC02 20.03.20 Wall moved MD GT

C03 19.05.20 Net lettable areas indicated toretail areas

AG SBC04 04.12.20 Minor updates MN ZMC05 15.12.20 Updated NIA MN SB

Page 3: CHARLES STREET - s3-eu-west-1.amazonaws.com

Core C01

Core C02

20-ID021

20-ID006FD60S VP

20-ID024FD30S VP

Store

Lift C01

Lift C02

A1

A1

B3

C1

C1

C3

D1

D2

D3

D4

D5

D6

E1

E3

E4

E5

F1F2

F3

F4

F5

F6

F7

F8

F9

87.180 FFL87.030 SFL

87.180 FFL87.030 SFL

L02 LobbyC2

H

B1

B1

G

A2

B2

20-ID101FD30S VP

20-ID022FD60S

20-ID104FD60S VP

20-ID016FD60

20-ID025FD60

20-ID012FD60S VP

20-ID023FD60

20-ID008FD60

20-ID009FD60

20-ID010FD60

L02OFFICE

STAIR C01

STAIR C02

Potential Office split

20-ID002FD60

20-ID004FD60

20-ID005FD60

20-ID015FD60

90.93087.180 FFL

20-ID01820-ID01920-ID020

20-ID026 20-ID027 20-ID028

Riser 10

Riser 09

Riser 01

Riser 08

Riser 06

Riser 05

Riser 04

Riser 02

L02OFFICE AMENITIES

20-ED017

DIS WC

Columns, beams and slab edge location is subject to detail survey of retained existing facade.

Columns, beams and slab edge location is subject to detail survey of retained existing facade.

KEY

CAT B - RETAIL SHOPFRONT, PART OF TENANT FITOUT PACKAGE

86.039

Steelwork beams in abeyance

E2

20-ID011FD60

G1

G2

Net Lettable Area 8159ft² (758m²)

CheckedByRevisionDateRev.

Client

Project

Drawing Title

Project Number Suitability

Checked byDrawn by

Scale @A1 Date

RevisionFile Identifier

Purpose of Issue

Dimensions to be verified on site.Use figured dimensions only. Do not work from reduced scale drawings. Please refer to scale and sheet size as indicated.

This drawing is the property of LEONARD DESIGN ARCHITECTS LTD.

Copyright is reserved by them and the drawing is issued on the condition that it is not copied, reproduced, retained or disclosed to any unauthorised person without the prior consent in writing of Leonard Design Architects Ltd. All rights reserved.

DO NOT SCALE

Project Status

leonard design architects4th floor, Albion House

5-13 Canal StreetNottingham. NG1 7EG. United Kingdom

t. +44 (0) 115 945 0080e. [email protected]

Key Plan

Orientation

CONSTRUCTION

Notes:

• All interfaces with retained and/or existing site conditions are based upon existing available survey information. LDA bear no responsibility for the accuracy of this information; contractor to provide all necessary survey and/or check dims as required to ensure compliance with design intent

• Basement perimeter wall setting out is indictive, subject to receipt of accurate survey information in connection with retained elements, and agreed build-up zone for proposed internal linings by specialist ground work sub-contractor

• All drawings and performance standards are subject to specialist consultant review and co-ordination (M&E, Acoustics and Fire)

• All structural information is indicative, refer to Structural Engineers’ details and specification for all specific structural information

• All M&E information is indicative, Refer to M&E Subcontractors’ details and specification for details for all specific services information

• All setting out and detailing is subject to ongoing detailed design development with suppliers and specialist sub-contractors for all key packages (Brickwork, Glazing, cladding, Insulation, Internal partitions etc.)

• All selected materials are subject to local statutory approvals (Planning and fire)

• All external works are indicative, Refer to Landscape Architect, Civil engineer and highways details and specifications for details for all specific services information

• All proposed works in connection with the retained elevation to Pinstone Street (including the returns) subject to receipt of accurate survey information to confirm the condition and setting out of the inner retained surface finish, and accurate setting out of all existing structural openings; This information also required in order to schedule proposed replacement windows.

• Columns, beams and slab edge location, is subject to detail survey of retained existing facade.

1 : 100

C04

Block C - Heart of City 2 -Sheffield

KG SB

16/07/18

GA Second Floor Plan

HOC

HOC - LDA - ZZ - 20 - DR - A - 2003

A1

CONSTRUCTION1 : 1001 L2 Proposed GA Second Floor Plan

0m1:100 1m 2m 4m 6m 8m 10m

0mm1:1 10mm 20mm 40mm 60mm 80mm 100mm

P01 21.08.18 Drawings issued for information LDA SBP02 11.10.18 Issued for Planning LDA SBP03 26.10.18 Drawings issued for Tender JP SBP04 09.11.18 Tender Issue LDA SBP05 15.04.19 Stair cores refined LDA JPSP06 07.05.19 Design development MD GTP07 23.05.19 Contractor Design Issue MD GT

P08 07.06.19 Grid alinged to S.E. grids; door,wall and window tags added

MD SB

P09 05.08.19 Insulation to external walls, doorratings, retail lift under review

MDP010 23.08.19 Drawings updated for CP issue MN SB

P011 14.11.19 Wall types rationalised; Wallreferances amended

GT SBP012 20.12.19 Preliminary issue for comments MD SBC01 20.04.20 Issued for CONSTRUCTION AG ZM

C02 26.06.20 Retail space developed into officespace. floor levels moved to up toalign to main floor plan

AG ZMC03 04.12.20 Minor updates MN ZMC04 15.12.20 Updated NIA MN SB

Page 4: CHARLES STREET - s3-eu-west-1.amazonaws.com

L03OFFICE

L03 Lobby

Core C0130-ID024FD30S VP

Lift C01

Lift C02

A1

A1

B3

C1

C1

C3

D1

D2

D3

D4

D5

D6

E1

E3

E4

E5

F1F2

F3

F4

F5

F6

F7

F8

F9

90.930 FFL90.780 SFL

90.930 FFL90.780 SFLC2

H

B1

B1

G

A2

B2

30-ID101FD30S VP

30-ID102FD60S VP

30-ID006FD60S VP

30-ID029

30-ID022FD60S

30-ID016FD60

30-ID025FD60

30-ID012FD60S VP

30-ID023FD60

30-ID008FD60

30-ID009FD60

30-ID010FD60

30-ID021

STAIR C01

STAIR C02 Potential Office split

30-ID002FD60

30-ID004FD60

30-ID005FD60

30-ID015FD60

94.680

92.723

93.539

94.680

90.930

30-ID02830-ID02730-ID026

30-ID020 30-ID019 30-ID018 30-ID017

Riser 10

Riser 09

Riser 01

Riser 08

Riser 06

Riser 05

Riser 04

Riser 02

L03OFFICE AMENITIES

Store

DIS WC

Columns, beams and slab edge location is subject to detail survey of retained existing facade.

Columns, beams and slab edge location is subject to detail survey of retained existing facade.

KEY

CAT B - RETAIL SHOPFRONT, PART OF TENANT FITOUT PACKAGE

Line of 2.1m clear height

Void

340

Blue dash line indicate line of floor slab edge

2710

486

899

314

4571

352

6235

332 334

Blue dash line indicate line of floor slab edge

Blue dash line indicate line of floor slab edge

1045

E2

G1

G2

Net Lettable Area 7093ft² (659m²)

CheckedByRevisionDateRev.

Client

Project

Drawing Title

Project Number Suitability

Checked byDrawn by

Scale @A1 Date

RevisionFile Identifier

Purpose of Issue

Dimensions to be verified on site.Use figured dimensions only. Do not work from reduced scale drawings. Please refer to scale and sheet size as indicated.

This drawing is the property of LEONARD DESIGN ARCHITECTS LTD.

Copyright is reserved by them and the drawing is issued on the condition that it is not copied, reproduced, retained or disclosed to any unauthorised person without the prior consent in writing of Leonard Design Architects Ltd. All rights reserved.

DO NOT SCALE

Project Status

leonard design architects4th floor, Albion House

5-13 Canal StreetNottingham. NG1 7EG. United Kingdom

t. +44 (0) 115 945 0080e. [email protected]

Key Plan

Orientation

CONSTRUCTION

Notes:

• All interfaces with retained and/or existing site conditions are based upon existing available survey information. LDA bear no responsibility for the accuracy of this information; contractor to provide all necessary survey and/or check dims as required to ensure compliance with design intent

• Basement perimeter wall setting out is indictive, subject to receipt of accurate survey information in connection with retained elements, and agreed build-up zone for proposed internal linings by specialist ground work sub-contractor

• All drawings and performance standards are subject to specialist consultant review and co-ordination (M&E, Acoustics and Fire)

• All structural information is indicative, refer to Structural Engineers’ details and specification for all specific structural information

• All M&E information is indicative, Refer to M&E Subcontractors’ details and specification for details for all specific services information

• All setting out and detailing is subject to ongoing detailed design development with suppliers and specialist sub-contractors for all key packages (Brickwork, Glazing, cladding, Insulation, Internal partitions etc.)

• All selected materials are subject to local statutory approvals (Planning and fire)

• All external works are indicative, Refer to Landscape Architect, Civil engineer and highways details and specifications for details for all specific services information

• All proposed works in connection with the retained elevation to Pinstone Street (including the returns) subject to receipt of accurate survey information to confirm the condition and setting out of the inner retained surface finish, and accurate setting out of all existing structural openings; This information also required in order to schedule proposed replacement windows.

• Columns, beams and slab edge location, is subject to detail survey of retained existing facade.

1 : 100

C05

Block C - Heart of City 2 -Sheffield

KG SB

16/07/18

GA Third Floor Plan

HOC

HOC - LDA - ZZ - 30 - DR - A - 2004

A1

CONSTRUCTION1 : 1001 L3 Proposed GA Third Floor Plan

0m1:100 1m 2m 4m 6m 8m 10m

0mm1:1 10mm 20mm 40mm 60mm 80mm 100mm

P01 21.08.18 Drawings issued for information LDA SBP02 11.10.18 Issued for Planning LDA SBP03 26.10.18 Drawings issued for Tender JP SBP04 09.11.18 Tender Issue LDA SBP05 15.04.19 Stair cores refined LDA JPSP06 07.05.19 Design development MD GTP07 23.05.19 Contractor Design Issue MD GT

P08 07.06.19 Grid alinged to S.E. grids; door,wall and window tags added

MD SB

P09 05.08.19 Insulation to external walls, doorratings, retail lift under review

MDP010 23.08.19 Drawings updated for CP issue MN SBP011 09.10.19 Area omitted MD SB

P012 14.11.19 Wall types rationalised; Wallreferances amended

GT SBP013 20.12.19 Preliminary issue for comments MD SBC01 20.04.20 Issued for CONSTRUCTION AG ZM

C02 26.06.20 Retail space developed into officespace. floor levels moved to up toalign to main floor plan

AG ZM

C03 30.06.20 Wall type amended, dormer wallsadded

MD ZMC04 04.12.20 Minor updates MN ZMC05 15.12.20 Updated NIA MN SB

Page 5: CHARLES STREET - s3-eu-west-1.amazonaws.com

Core C01

40-ID101FD30S VP

Lift C01

Lift C02

Core C02

17408

17407

A1

A1

B3

C1

C1

C3

D1

D2

D3

D4

D5

D6

E1

E3

E4

E5

F1F2

F3

F4

F5

F6

F7

F8

F9

94.680 FFL94.530 SFL

94.680 FFL94.530 SFL

L04 LobbyC2

H

B1

B1

G

A2

B2

40-ID102FD60S VP

40-ID016FD60

40-ID008FD60

40-ID027

40-ID020

40-ID023FD60

40-ID012FD60S VP

40-ID021FD60

40-ID022FD30S VP

40-ID009FD60

40-ID010FD60

40-ID017

STAIR C01

STAIR C02

Potential Office split

40-ID015FD60

40-ID002FD60

40-ID004FD60

40-ID005FD60

98.430

98.43094.680

40-ID02640-ID02540-ID024

40-ID019 40-ID018

Riser 01

Riser 08

Riser 06

Riser 05

Riser 04

Riser 02

Riser 10

Riser 09

L04OFFICE AMENITIES

40-ED006FD60S VP

L04OFFICE Store

DIS WC

E2

40-ID011FD60

G1

G1

1831

1219

1268

195

612 634 1692

1350

1849

690

46811296

1159

2489

2977

1486

3472

Net Lettable Area 5264ft² (489m²)

CHIMNEY TO BE MOVED AWAY FROM THE FACADE IN DUE COURSE.PLEASE BE AWARE THAT THE SECONDARY STEEL WORK THAT SUPPORTS IT, HAS ALREADY BEEN CO-ORDINATED IN THE RIGHT LOCATION.

ACCESS TO THE ROOF

CheckedByRevisionDateRev.

Client

Project

Drawing Title

Project Number Suitability

Checked byDrawn by

Scale @A1 Date

RevisionFile Identifier

Purpose of Issue

Dimensions to be verified on site.Use figured dimensions only. Do not work from reduced scale drawings. Please refer to scale and sheet size as indicated.

This drawing is the property of LEONARD DESIGN ARCHITECTS LTD.

Copyright is reserved by them and the drawing is issued on the condition that it is not copied, reproduced, retained or disclosed to any unauthorised person without the prior consent in writing of Leonard Design Architects Ltd. All rights reserved.

DO NOT SCALE

Project Status

leonard design architects4th floor, Albion House

5-13 Canal StreetNottingham. NG1 7EG. United Kingdom

t. +44 (0) 115 945 0080e. [email protected]

Key Plan

Orientation

CONSTRUCTION

Notes:

• All interfaces with retained and/or existing site conditions are based upon existing available survey information. LDA bear no responsibility for the accuracy of this information; contractor to provide all necessary survey and/or check dims as required to ensure compliance with design intent

• Basement perimeter wall setting out is indictive, subject to receipt of accurate survey information in connection with retained elements, and agreed build-up zone for proposed internal linings by specialist ground work sub-contractor

• All drawings and performance standards are subject to specialist consultant review and co-ordination (M&E, Acoustics and Fire)

• All structural information is indicative, refer to Structural Engineers’ details and specification for all specific structural information

• All M&E information is indicative, Refer to M&E Subcontractors’ details and specification for details for all specific services information

• All setting out and detailing is subject to ongoing detailed design development with suppliers and specialist sub-contractors for all key packages (Brickwork, Glazing, cladding, Insulation, Internal partitions etc.)

• All selected materials are subject to local statutory approvals (Planning and fire)

• All external works are indicative, Refer to Landscape Architect, Civil engineer and highways details and specifications for details for all specific services information

• All proposed works in connection with the retained elevation to Pinstone Street (including the returns) subject to receipt of accurate survey information to confirm the condition and setting out of the inner retained surface finish, and accurate setting out of all existing structural openings; This information also required in order to schedule proposed replacement windows.

• Columns, beams and slab edge location, is subject to detail survey of retained existing facade.

1 : 100

C03

Block C - Heart of City 2 -Sheffield

KG SB

16/07/18

GA Fourth Floor Plan

HOC

HOC - LDA - ZZ - 40 - DR - A - 2005

A1

CONSTRUCTION1 : 1001 L4 Proposed GA Fourth Floor Plan

0m1:100 1m 2m 4m 6m 8m 10m

0mm1:1 10mm 20mm 40mm 60mm 80mm 100mm

P01 21.08.18 Drawings issued for information LDA SBP02 11.10.18 Issued for Planning LDA SBP03 26.10.18 Drawings issued for Tender JP SBP04 09.11.18 Tender Issue LDA SBP05 15.04.19 Stair cores refined LDA JPSP06 07.05.19 Design development MD GTP07 23.05.19 Contractor Design Issue MD GT

P08 07.06.19 Grid alinged to S.E. grids; door,wall and window tags added

MD SBP09 05.08.19 Door ratings MDP010 23.08.19 Drawings updated for CP issue MN SB

P011 14.11.19 Wall types rationalised; Wallreferances amended

GT SBP012 20.12.19 Preliminary issue for comments MD SBC01 20.04.20 Issued for CONSTRUCTION AG ZMC02 04.12.20 Minor updates MN ZMC03 15.12.20 Updated NIA MN SB

Page 6: CHARLES STREET - s3-eu-west-1.amazonaws.com

L05OFFICE

L05 Lobby

Core C01

Core C02

Lift C01

A1

A1

B3

C1

C1

C3

D1

D2

D3

D4

D5

D6

E1

E3

E4

E5

F1F2

F3

F4

F5

F6

F7

F8

F9

Lift C02

98.430 FFL98.280 SFL

98.430 FFL98.280 SFL

C2

H

B1

B1

G

A2

B2

50-ID101FD30S VP

50-ID102FD60S VP

50-ID018FD60

50-ID008FD60S VP

50-ID029

50-ID022FD60S

50-ID025FD60

50-ID014FD60S VP

50-ID023FD60

50-ID024FD30S VP

50-ID010FD60

50-ID011FD60

50-ID012FD60

50-ID019

STAIR C01

STAIR C02

Potential Office split

50-ID017FD60

50-ID002FD60

50-ID004FD60

50-ID006FD60

102.180

102.18098.430

50-ID02850-ID02750-ID026

50-ID021 50-ID020

Riser 01

Riser 08

Riser 06

Riser 05

Riser 04

Riser 02

Riser 10

Riser 09

L05OFFICE AMENITIES

Store

DIS WC

E2

50-ID013FD60

G1

G2

Net Lettable Area 5260ft² (489m²)

CheckedByRevisionDateRev.

Client

Project

Drawing Title

Project Number Suitability

Checked byDrawn by

Scale @A1 Date

RevisionFile Identifier

Purpose of Issue

Dimensions to be verified on site.Use figured dimensions only. Do not work from reduced scale drawings. Please refer to scale and sheet size as indicated.

This drawing is the property of LEONARD DESIGN ARCHITECTS LTD.

Copyright is reserved by them and the drawing is issued on the condition that it is not copied, reproduced, retained or disclosed to any unauthorised person without the prior consent in writing of Leonard Design Architects Ltd. All rights reserved.

DO NOT SCALE

Project Status

leonard design architects4th floor, Albion House

5-13 Canal StreetNottingham. NG1 7EG. United Kingdom

t. +44 (0) 115 945 0080e. [email protected]

Key Plan

Orientation

CONSTRUCTION

Notes:

• All interfaces with retained and/or existing site conditions are based upon existing available survey information. LDA bear no responsibility for the accuracy of this information; contractor to provide all necessary survey and/or check dims as required to ensure compliance with design intent

• Basement perimeter wall setting out is indictive, subject to receipt of accurate survey information in connection with retained elements, and agreed build-up zone for proposed internal linings by specialist ground work sub-contractor

• All drawings and performance standards are subject to specialist consultant review and co-ordination (M&E, Acoustics and Fire)

• All structural information is indicative, refer to Structural Engineers’ details and specification for all specific structural information

• All M&E information is indicative, Refer to M&E Subcontractors’ details and specification for details for all specific services information

• All setting out and detailing is subject to ongoing detailed design development with suppliers and specialist sub-contractors for all key packages (Brickwork, Glazing, cladding, Insulation, Internal partitions etc.)

• All selected materials are subject to local statutory approvals (Planning and fire)

• All external works are indicative, Refer to Landscape Architect, Civil engineer and highways details and specifications for details for all specific services information

• All proposed works in connection with the retained elevation to Pinstone Street (including the returns) subject to receipt of accurate survey information to confirm the condition and setting out of the inner retained surface finish, and accurate setting out of all existing structural openings; This information also required in order to schedule proposed replacement windows.

• Columns, beams and slab edge location, is subject to detail survey of retained existing facade.

1 : 100

C03

Block C - Heart of City 2 -Sheffield

KG SB

16/07/18

GA Fifth Floor Plan

HOC

HOC - LDA - ZZ - 50 - DR - A - 2006

A1

CONSTRUCTION1 : 1001 L5 Proposed GA Fifth Floor Plan

0m1:100 1m 2m 4m 6m 8m 10m

0mm1:1 10mm 20mm 40mm 60mm 80mm 100mm

P01 21.08.18 Drawings issued for information LDA SBP02 11.10.18 Issued for Planning LDA SBP03 26.10.18 Drawings issued for Tender JP SBP04 09.11.18 Tender Issue LDA SBP05 15.04.19 Stair cores refined LDA JPSP06 07.05.19 Design development MD GTP07 23.05.19 Contractor Design Issue MD GT

P08 07.06.19 Grid alinged to S.E. grids; door,wall and window tags added

MD SBP09 05.08.19 Door ratings MDP010 23.08.19 Drawings updated for CP issue MN SB

P011 14.11.19 Wall types rationalised; Wallreferances amended

GT SBP012 20.12.19 Preliminary issue for comments MD SBC01 20.04.20 Issued for CONSTRUCTION AG ZMC02 04.12.20 Minor updates MN ZMC03 15.12.20 Updated NIA MN SB

Page 7: CHARLES STREET - s3-eu-west-1.amazonaws.com

L06OFFICE

L06 Lobby

Core C02

Core C01

Lift C02

Lift C01

A1

A1

B3

C1

C1

C3

D1

D2

D3

D4

D5

D6

E1

E3

E4

E5

F1F2

F3

F4

F5

F6

F7

F8

F9

102.180 FFL102.030 SFL

102.180 FFL102.030 SFL

C2

H

B1

B1

G

A2

B2

60-ID101FD30S VP

60-ID102FD60S VP

60-ID017FD60

60-ID010FD60

60-ID011FD60

60-ID007FD60S VP

60-ID028

60-ID021

60-ID024FD60

60-ID006FD60

60-ID004FD60

60-ID013FD60S VP

60-ID018

60-ID022FD60

60-ID023FD30S VP

60-ID009FD60

STAIR C01

STAIR C02

Potential Office split

60-ID002FD60

60-ID016FD60

103.484

105.930102.180

60-ID02760-ID02660-ID025

60-ID020 60-ID019

Riser 01

Riser 08

Riser 06

Riser 05

Riser 04

Riser 02

Riser 10

Riser 09

L06OFFICE AMENITIES

Store

DIS WC

E2

60-ID012FD60

G1

G2

Net Lettable Area 5264ft² (489m²)

CheckedByRevisionDateRev.

Client

Project

Drawing Title

Project Number Suitability

Checked byDrawn by

Scale @A1 Date

RevisionFile Identifier

Purpose of Issue

Dimensions to be verified on site.Use figured dimensions only. Do not work from reduced scale drawings. Please refer to scale and sheet size as indicated.

This drawing is the property of LEONARD DESIGN ARCHITECTS LTD.

Copyright is reserved by them and the drawing is issued on the condition that it is not copied, reproduced, retained or disclosed to any unauthorised person without the prior consent in writing of Leonard Design Architects Ltd. All rights reserved.

DO NOT SCALE

Project Status

leonard design architects4th floor, Albion House

5-13 Canal StreetNottingham. NG1 7EG. United Kingdom

t. +44 (0) 115 945 0080e. [email protected]

Key Plan

Orientation

CONSTRUCTION

Notes:

• All interfaces with retained and/or existing site conditions are based upon existing available survey information. LDA bear no responsibility for the accuracy of this information; contractor to provide all necessary survey and/or check dims as required to ensure compliance with design intent

• Basement perimeter wall setting out is indictive, subject to receipt of accurate survey information in connection with retained elements, and agreed build-up zone for proposed internal linings by specialist ground work sub-contractor

• All drawings and performance standards are subject to specialist consultant review and co-ordination (M&E, Acoustics and Fire)

• All structural information is indicative, refer to Structural Engineers’ details and specification for all specific structural information

• All M&E information is indicative, Refer to M&E Subcontractors’ details and specification for details for all specific services information

• All setting out and detailing is subject to ongoing detailed design development with suppliers and specialist sub-contractors for all key packages (Brickwork, Glazing, cladding, Insulation, Internal partitions etc.)

• All selected materials are subject to local statutory approvals (Planning and fire)

• All external works are indicative, Refer to Landscape Architect, Civil engineer and highways details and specifications for details for all specific services information

• All proposed works in connection with the retained elevation to Pinstone Street (including the returns) subject to receipt of accurate survey information to confirm the condition and setting out of the inner retained surface finish, and accurate setting out of all existing structural openings; This information also required in order to schedule proposed replacement windows.

• Columns, beams and slab edge location, is subject to detail survey of retained existing facade.

1 : 100

C03

Block C - Heart of City 2 -Sheffield

KG SB

16/07/18

GA Sixth Floor Plan

HOC

HOC - LDA - ZZ - 60 - DR - A - 2007

A1

CONSTRUCTION1 : 1001 L6 Proposed GA Sixth Floor Plan

0m1:100 1m 2m 4m 6m 8m 10m

0mm1:1 10mm 20mm 40mm 60mm 80mm 100mm

P01 21.08.18 Drawings issued for information LDA SBP02 11.10.18 Issued for Planning LDA SBP03 26.10.18 Drawings issued for Tender JP SBP04 09.11.18 Tender Issue LDA SBP05 15.04.19 Stair cores refined LDA JPSP06 07.05.19 Design development MD GTP07 23.05.19 Contractor Design Issue MD GT

P08 07.06.19 Grid alinged to S.E. grids; door,wall and window tags added

MD SBP09 05.08.19 Door ratings MDP010 23.08.19 Drawings updated for CP issue MN SB

P011 14.11.19 Wall types rationalised; Wallreferances amended

GT SBP012 20.12.19 Preliminary issue for comments MD SBC01 20.04.20 Issued for CONSTRUCTION AG ZMC02 04.12.20 Minor updates MN ZMC03 15.12.20 Updated NIA MN SB

Page 8: CHARLES STREET - s3-eu-west-1.amazonaws.com

L07OFFICE

L07 Lobby

Core C02

70-ED004

70-ID020

Lift C01

Lift C02

M&E 02PLANT

Core C01

A1

A1

B3

B3

C1

C3

D1

D2

D3

D4

D5

D6

E1

E3

E4

E5

F1F2

F3

F4

F5

F6

F7

F8

F9

105.930 FFL105.780 SFL

105.930 FFL105.780 SFL

C2

H

B1

B1

G

A2

B2

70-ID101FD30S VP

70-ID007FD60S VP

70-ID015FD60S

70-ID016FD60

70-ID018FD60

70-ID102FD60S VP

70-ID017FD30S VP

70-ID009FD60

70-ED005

70-ED001

STAIR C01

STAIR C02

ExternalPLANT

BLUE ROOF UNDER PLANT

STAIR C04

L7 PLANT SPACE

SHIPS LADDER

70-ID002FD60

70-ID004FD60

70-ID006FD60

AOV ABOVE

103.973

109.030

105.930

70-ID019

70-ID014 70-ID013

70-ED002

Riser 01 below

Riser 08

Riser 06

Riser 05

Riser 04

Riser 02

Riser 10

Riser 09

L07OFFICE AMENITIES

DIS WCBLUE ROOF

STEP UP TO ROOF

70-ED003

STEP UP TO ROOF

STEPS UP TO ROOF

E2

VIEW 1

VIEW 2

VIEW 3WEIR 1

G1

G2

SHIPS LADDER NEED TO HAVE MID-LANDING.CONDUIT TRAYS NEED TO MOVE OUT, TO GET CLEAR HEADROOM.

SHIPS LADDER NEED TO HAVE MID-LANDING.CONDUIT TRAYS NEED TO MOVE OUT, TO GET CLEAR HEADROOM.

Net Lettable Area 2298ft² (213m²)

L07OFFICE

M&E 02PLANT

105.930 FFL105.780 SFL

105.930 FFL105.780 SFL

ExternalPLANT

BLUE ROOF UNDER PLANT

L7 PLANT SPACE

103.973109.030

105.930

BLUE ROOF KEY

Blue Roof Fully Paved( Plants seats on paving)

CheckedByRevisionDateRev.

Client

Project

Drawing Title

Project Number Suitability

Checked byDrawn by

Scale @A1 Date

RevisionFile Identifier

Purpose of Issue

Dimensions to be verified on site.Use figured dimensions only. Do not work from reduced scale drawings. Please refer to scale and sheet size as indicated.

This drawing is the property of LEONARD DESIGN ARCHITECTS LTD.

Copyright is reserved by them and the drawing is issued on the condition that it is not copied, reproduced, retained or disclosed to any unauthorised person without the prior consent in writing of Leonard Design Architects Ltd. All rights reserved.

DO NOT SCALE

Project Status

leonard design architects4th floor, Albion House

5-13 Canal StreetNottingham. NG1 7EG. United Kingdom

t. +44 (0) 115 945 0080e. [email protected]

Key Plan

Orientation

CONSTRUCTION

Notes:

• All interfaces with retained and/or existing site conditions are based upon existing available survey information. LDA bear no responsibility for the accuracy of this information; contractor to provide all necessary survey and/or check dims as required to ensure compliance with design intent

• Basement perimeter wall setting out is indictive, subject to receipt of accurate survey information in connection with retained elements, and agreed build-up zone for proposed internal linings by specialist ground work sub-contractor

• All drawings and performance standards are subject to specialist consultant review and co-ordination (M&E, Acoustics and Fire)

• All structural information is indicative, refer to Structural Engineers’ details and specification for all specific structural information

• All M&E information is indicative, Refer to M&E Subcontractors’ details and specification for details for all specific services information

• All setting out and detailing is subject to ongoing detailed design development with suppliers and specialist sub-contractors for all key packages (Brickwork, Glazing, cladding, Insulation, Internal partitions etc.)

• All selected materials are subject to local statutory approvals (Planning and fire)

• All external works are indicative, Refer to Landscape Architect, Civil engineer and highways details and specifications for details for all specific services information

• All proposed works in connection with the retained elevation to Pinstone Street (including the returns) subject to receipt of accurate survey information to confirm the condition and setting out of the inner retained surface finish, and accurate setting out of all existing structural openings; This information also required in order to schedule proposed replacement windows.

• Columns, beams and slab edge location, is subject to detail survey of retained existing facade.

As indicated

C06

Block C - Heart of City 2 -Sheffield

KG SB

16/07/18

GA Seventh Floor Plan

HOC

HOC - LDA - ZZ - 70 - DR - A - 2008

A1

CONSTRUCTION1 : 1001 L7 Proposed GA Seventh Floor Plan

0m1:100 1m 2m 4m 6m 8m 10m

0mm1:1 10mm 20mm 40mm 60mm 80mm 100mm

P01 21.08.18 Drawings issued for information LDA SBP02 11.10.18 Issued for Planning LDA SBP03 26.10.18 Drawings issued for Tender JP SBP04 09.11.18 Tender Issue LDA SBP05 15.04.19 Stair cores refined LDA JPSP06 07.05.19 Design development MD GTP07 23.05.19 Contractor Design Issue MD GT

P08 07.06.19 Grid alinged to S.E. grids; door,wall and window tags added

MD SBP09 05.08.19 Door ratings MDP010 23.08.19 Drawings updated for CP issue MN SB

P011 14.11.19 Wall types rationalised; Wallreferances amended

GT SBP012 20.12.19 Preliminary issue for comments MD SBC01 20.04.20 Issued for CONSTRUCTION AG ZMC02 24.04.20 Issued for CONSTRUCTION ZM SBC03 31.07.20 Roof Detail Update YX ZMC04 13.08.20 Door tags amended. JL ZMC05 04.12.20 Minor updates MN ZMC06 15.12.20 Updated NIA MN SB

1 : 2002 L7 Proposed GA Seventh Floor Plan

PLEASE BE AWARE THE CURRENTLY PLANT LAYOUT HAS BEEN PURPOSELY LEFT ON SO AS TO UNDERSTAND THAT IN RELATION TO GETTING ACCESS TO THE SHIP LADDER

ACCESS ROUTE TO SHIPS LADDER

PLANT TURNED OFF SO THE EXTENT OF PAVED ROOF CAN BE SEEN