Chapter 29

39
Chapter 29 Product Control and Air Monitoring

description

Chapter 29. Product Control and Air Monitoring. Introduction. Product control techniques can provide quick reduction in damage Reduction of surface area reduces danger to responders and community Use of air monitoring devices is becoming more commonplace - PowerPoint PPT Presentation

Transcript of Chapter 29

Page 1: Chapter 29

Chapter 29

Product Control and Air Monitoring

Page 2: Chapter 29

Introduction• Product control techniques can

provide quick reduction in damage• Reduction of surface area reduces

danger to responders and community

• Use of air monitoring devices is becoming more commonplace

• To ensure firefighter safety, basic air monitoring must be accomplished

29.2

Page 3: Chapter 29

Defensive Operations• According to NFPA, three large tasks

fit into operations-level tactical response:– Basic air monitoring– Containment– Confinement

• Type and level of PPE for each task will vary with chemical involved

29.3

Page 4: Chapter 29

Absorption• First responders often asked to clean

up spilled material• Absorption commonly used for fuel

and oil products• Know type of absorption material

carried on apparatus• Filter fences hold absorbent material

29.4

Page 5: Chapter 29

29.5

Figure 29-3 A screen fence can be used to collect the absorbent material floating on the water after the absorbent has collected the spilled material. The water flows through the fence below the absorbent.

Page 6: Chapter 29

Diking and Damming• Quantity of material spilled determines

extent of diking and damming operations performed

• Use earth, sand, or rocks for dikes or dams

• Local or state highway departments are a good source for materials

• Do not set barrier too close to spill• Two basic dams:

– Overflow– Underflow

29.6

Page 7: Chapter 29

29.7

Figure 29-4 The overflow dam allows the clean water to flow over the dam and collects the spilled material at the base of the dam. The underflow dam collects the spilled material on top and allows the water to flow through the bottom of the dam.

Page 8: Chapter 29

29.8

Figure 29-5 Overflow dam. Figure 29-6 Underflow dam.

Page 9: Chapter 29

Diverting• Almost anything can be used• Keep a running spill from entering a

storm drain• Can be used for spills on water• Dig trench alongside waterway to

collect spilled material

29.9

Page 10: Chapter 29

Retention• Most common method is digging a

hole• Creating a large enough containment

area is paramount to success• If one large area cannot be dug, dig

several smaller holes in a row

29.10

Page 11: Chapter 29

29.11

Figure 29-11 Building a retention area is a good method for holding released products. Retention areas can be dug from existing earth or created with truckloads of sand or dirt. Small holding areas can be hand dug, but for larger spills heavy equipment is required.

Page 12: Chapter 29

Dilution• Not always the solution for pollution• Flushing of material into waterway is

not acceptable• Dilution may work when combined

with other containment tactics

29.12

Page 13: Chapter 29

Vapor Dispersion• Material that is being released must

be water soluble• Not recommended unless a life

threat exists• Water at natural gas leaks further

complicates repair• Use of water can also result in

creation of another substance

29.13

Page 14: Chapter 29

Vapor Suppression• With use of firefighting foam• Type of material spilled dictates the

type of foam• Before application of foam,

responders should ensure material is contained

29.14

Page 15: Chapter 29

Remote Shutoffs• Not usually a tactic used by first

responders• Remote shutoffs could be operated

by first responders• Usually well marked as emergency

shutoffs

29.15

Page 16: Chapter 29

Air Monitoring at the First Responder Operations Level

• Air monitoring is one of the most important tasks to accomplish– pH detection– Combustible gas detector– Photoionization detector (PID)

• Most fire service responders have reasonable understanding of combustible gas indicators

29.16

Page 17: Chapter 29

29.17

Figure 29-13 First responders commonly use devices that detect the presence of flammable gases, carbon monoxide, and hydrogen sulfide and determine the oxygen content. This detector also detects the presence of common toxic vapors.

Page 18: Chapter 29

Regulations and Standards• HAZWOPER regulation does not

provide a lot of specific requirements for air monitoring

• NFPA 472 is fairly generic• Important for first responders to

understand how monitors work

29.18

Page 19: Chapter 29

Air Monitor Configurations• Most departments purchase a

three-, four-, or five-gas instrument• Also called a multi-gas detector• Inexpensive compared to other

detection devices used by hazardous material team

• Sensors need replacement• Problems created by lack of

maintenance and adequate training29.19

Page 20: Chapter 29

Meter Terminology• Responder must understand basic

terminology that is generic to all monitors– Bump test– Calibration– Reaction time– Recovery time– Relative response

29.20

Page 21: Chapter 29

Bump Test• Exposes a monitor to known gases,

allowing the monitor to go into alarm mode

• Most manufacturers provide bump gas cylinders

• Used to ensure that alarms function and instrument is reading

29.21

Page 22: Chapter 29

Calibration• Determine if monitor responds

accurately to exposure to a known quantity of gas

• When new sensors are installed, monitor should be calibrated

• Regularity of calibration is subject to great debate

29.22

Page 23: Chapter 29

29.23

Figure 29-15 Calibration involves exposing the instrument on the right to a known quantity of gases to ensure that it is reading the gases correctly. This kit calibrates the monitor with a variety of gases.

Page 24: Chapter 29

Reaction Time• All monitors have a lag time, better

known as reaction time• Monitors operating without a pump

are in diffusion mode– Will have 15- to 30-second lag time

• Monitors operating with a pump have reaction time of 7 to 30 seconds

• WMD detection devices may take up to 90 seconds to react

29.24

Page 25: Chapter 29

Recovery Time• Recovery time is the amount of time it

takes the monitor to clear itself of air sample

• Affected by:– Chemical and physical properties of sample– Amount of sampling hose– Amount absorbed by monitor

• Sometimes instrument must be taken out of environment and restarted

• Reaction time affects overall recovery time

29.25

Page 26: Chapter 29

Relative Response• When gas monitor is purchased, it is

set to read a specific type of gas• Relative response describes the way

monitor reacts to gas other than the one it was calibrated for

• Each person operating an air monitor must have a basic knowledge of relative response

• Actual LEL reading = Detector reading Response curve factor

29.26

Page 27: Chapter 29

29.27

Table 29-1 Correction Factors (Calibrated to Pentane)a

Page 28: Chapter 29

Oxygen Monitors• Oxygen: one of most important things to

sample• Normal air contains 20.9 percent oxygen

– Below 19.5 considered a health risk– Above 23.5 considered a fire risk

• Oxygen-enriched atmospheres result from a chemical reaction involving oxidizers

• Temperature below zero degrees can permanently damage the sensor

• Requires calibration at pressure of sample

29.28

Page 29: Chapter 29

Flammable Gas Indicators• All of these types of sensors work, some

better than others in different situations– Catalytic bead sensor– Metal oxide sensor– Infrared sensor

• Most FGIs read up to the LEL of the gas– Longer the exposure is above the LEL, the

quicker it loses its life

• Any flammable gas will cause a reaction in the sensor

29.29

Page 30: Chapter 29

29.30

Figure 29-16 Examples of flammable gas indicators: catalytic bead, metal oxide, and infrared.

Page 31: Chapter 29

Toxic Gas Monitors• Sensors commonly used in multi-gas

monitors– Usually measure CO and H2S

• Toxic sensors are available for a variety of gases

• Most toxic sensors are electrochemical sensors– Have electrodes and a chemical mixture sealed

in a sensor housing

• Gas passes over the sensor, causing chemical reaction, creating electrical charge

• Toxic sensors display parts per million29.31

Page 32: Chapter 29

Tactical Use of Multi-Gas Detection Devices

• MOS sensors react quickly and detect low levels of flammable gas– Not accurate, fluctuate considerably– Detect water vapor and give erroneous

readings• Catalytic bead and infrared both are

accurate• Most flammable gas detectors only read

methane accurately• When LEL sensor alarms at 10 percent

level for an unidentified material, they should retreat

29.32

Page 33: Chapter 29

Other Detectors• Following detectors are used by a

hazardous materials team, but should be understood by first responder– Photoionization detectors– Radiation pagers– Colorimetric tubes– Chip measurement system– Air monitoring equipment

29.33

Page 34: Chapter 29

Using Air Monitoring Equipment

• Assure battery level and bump test the instrument

• Understand what the flammable gas sensor detects and what it does not detect.

• The oxygen sensor indicates the level of oxygen

• Understand the alarm levels for the instrument being used

29.34

Page 35: Chapter 29

Carbon Monoxide Incidents• 40,000 people treated for carbon monoxide

poisoning each year• SCBA functioning when rescuing residents• On arrival, fire service monitors will not read

CO even if present in dangerous concentrations

• Brand and type of CO detector determines performance– Biomimetic– Metal oxide– Electrochemical

29.35

Page 36: Chapter 29

Biomimetic• Gel-like material• Prone to false alarms• May need 24 to 48 hours to clear

itself

29.36

Page 37: Chapter 29

Metal Oxide• Same type of sensor used in

combustible gas detector• Has cross sensitivities and reacts to

other gases• Responders could be walking into a

flammable atmosphere• Requires a lot of energy, provides a

digital readout• Clears in less than 24 hours

29.37

Page 38: Chapter 29

Electrochemical• Also referred to as an instant detection and

response sensor• Two charged poles in a chemical slurrie

– CO causes a chemical reaction– Changes the resistance within the housing

• Provides an instant reading of CO– Internal mechanism that checks the sensor

• Provides the best sensing capability

29.38

Page 39: Chapter 29

Lessons Learned• Defensive product control is a key

component• First responders have equipment

necessary to handle these tasks• Limiting spill will mitigate incident

sooner• First responders are becoming more

involved with air monitoring• Understanding action levels are an

important consideration for safety29.39