TRC Certificate of Compliance
Training Research Co., Ltd.
hereby certifies that
Moxa Technologies Co., Ltd.
ioMirror Ethernet Peer-to-Peer I/O Server Model: ioMirror E3210 Peer-to-Peer I/O
Applicant address
Fl. 4, No. 135, Lane 235, Pao-Chiao Rd., Shing Tien City, Taipei, Taiwan, R.O.C.
is fulfilled
the 47 CFR, Part 2 and Part 15 of FCC Rules
The Certificate is authorized under Declaration of Conformity
Test procedures: ANSI C63.4 2003 Test Date: March 30, 2007
Certificate Registration No.: M4715061017
April 12, 2007
-------------------------------------- General Manager, Frank Tsai
Test Report ------------------------------------------------------------------------------- 1/26
Report No.: M4715061017 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Report No. M4715061017
Specifications FCC Part 15.109(g), CISPR 22, Class A Test method ANSI C63.4 2003
Applicant Moxa Technologies Co., Ltd.
Applicant Fl. 4, No. 135, Lane 235, Pao-Chiao Rd., Shing Tien City, address Taipei, Taiwan, R.O.C.
Items tested ioMirror Ethernet Peer-to-Peer I/O Server Model No. ioMirror E3210 Peer-to-Peer I/O EUT Condition Engineering sample; Pre-production; Final production (Sample # M471017) Results Compliance (As detailed within this report) Date 03/21/2007 (month / day / year) (Sample received) 03/21/2007 ~ 03/30/2007 (Test) Prepared by Project Engineer (Jack Tsai) Authorized by General Manager (Frank Tsai) Issue date April 04, 2007 (month / day / year) Modifications None Tested by Training Research Co., Ltd. Office at No. 255, NanYang Street, Hsichih, Taipei Hsien 221, Taiwan Open site at No. 2, Lane 530, Pa-Lian Rd., Sec. 1, Hsichih, Taipei Hsien, Taiwan Conditions of issue :
(1) This test report shall not be reproduced except in full, without written approval of TRC. And the test result contained within this report only relate to the sample submitted for testing.
(2) This report must not be used by the client to claim product endorsement by NVLAP or any agency of U.S. Government.
(3) This test report, measurements made by TRC are traceable to the NIST only Conducted and Radiated Method.
Test Report ------------------------------------------------------------------------------- 2/26
Report No.: M4715061017 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Contents
CHAPTER 1 INTRODUCTION .......................................................................... 3 Description of EUT ................................................................................................... 3 Connections of EUT .................................................................................................. 3 Test method ............................................................................................................... 3 Configuration of Test Setup....................................................................................... 4 Connections of equipment ......................................................................................... 4 List of Support Equipment......................................................................................... 5
CHAPTER 2 CONDUCTED EMISSION TEST .................................................... 6 Test condition and setup ............................................................................................ 6 List of test Instrument................................................................................................ 7 Conducted Test Placement: (Front view and Side view)........................................... 8
CHAPTER 3 RADIATED EMISSION TEST ........................................................ 9 Test condition and setup ............................................................................................ 9 List of test Instrument.............................................................................................. 10 Radiated Test Placement: (Front view and Rear view) ........................................... 11
APPENDIX A ..................................................................................................... 12 Test Result of Conducted Emissions for Mains power............................................ 12
APPENDIX B ..................................................................................................... 13 Test Result of Radiated Emission for Horizontal .................................................... 13 Test Result of Radiated Emission for Vertical ........................................................ 13
APPENDIX C ..................................................................................................... 14 Photographs of EUT ................................................................................................ 14
APPENDIX D ..................................................................................................... 25 LABEL Information of EUT ................................................................................... 25
Test Report ------------------------------------------------------------------------------- 3/26
Report No.: M4715061017 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Chapter 1 Introduction Description of EUT
The EUT was designed for system integrators to acquire and control remote digital and analog devices over RS-485. Types of digital on/off devices include proximity switches, mechanical switches, push buttons, optical sensors, LEDs, and light switches. Types of analog devices include pH, conductivity, temperature, humidity, pressure, flow, actuator, and valves. The EUT of servers can work with the standard Modbus protocol. SCADA software or the MXIO DLL library may be used to access the server.
It offers 8-CH isolated DI and 8-CH isolated DO, LAN Port for 10/100 connectivity. Connections of EUT
(1) The POWER port of EUT is connected with the AC mains supply by power cable. (2) DIO-A Terminal Block connects to DIO-B Terminal Block by unshielded cables. (3) The LAN Port connected with LAN cards, which installed in far-end computers.
Test method
Pretest was found that the emission of operating mode is worse than standby mode. So, the final test is made at the operating mode.
During the measurement, there are two speeds: “10x10Mbps“, “100x100Mbps“, those speeds simultaneous set up. The software provided by the manufacturer to control the EUT in the mode of continuous TX / RX.
The test placement as the photographs showed is the worst case emission placed. (If the emission is close to the ambient, the resolution BW and view resolution will be reduced and the data will be recorded by detection of maximum hold peak mode.)
Deviation from test standard: No deviation.
The testing configuration of test setup is showing in the next page.
Test Report ------------------------------------------------------------------------------- 4/26
Report No.: M4715061017 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Configuration of Test Setup Connections of equipment
EUT:
* DIO Cable x 9……......... 10m length, non-shielded, no ferrite core
* RJ45 Cable x 1.……….. 20m length, non-shielded, no ferrite core
AC mains supply
PC
LAN Card (10/100Mbps)
Far-end
EUT
Adapter
Test Report ------------------------------------------------------------------------------- 5/26
Report No.: M4715061017 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
List of Support Equipment PC : IBM ThinkPad T43 Model No. : 2668-IVE Serial No. : L3TGYY FCC ID : N/A, DoC Approved BSMI : R33B65 DGT : ETC093LPD0126, CTL093LPD0257 Power adaptor : IBM Part No. : 92P1018 Serial No. : 11S92P1018Z1ZAPU57M9W6 REV: D FCC ID : N/A, DoC Approved BSMI : D33030 Power type : 100 ~ 240VAC / 50 ~ 60Hz, 1.0 ~ 0.4A, Switching Power cord : Primary: Non-shielded, 1.0m length, Plastic hood, No ferrite core Secondary: Shielded, 1.84m length, Plastic hood, ferrite core LAN Card : D-Link Model No. : DFE-530TX Serial No. : 0050BAE32FF3, 0050BAE3158B FCC ID : N/A, DoC Approved Power type : Powered by PC Fiber- Optic Card : Cameo Communications, Inc. FCC ID : N/A, DoC Approved Power type : Powered by PC Power adaptor : Moxa Technologies Co., Ltd. Model. : TF-659 Power type : 120VAC / 50 Hz; 12VDC Power cord : Primary: Non-shielded, 1.65m length, Plastic hood, No ferrite core Secondary: Non-shielded, 0.45m length, Plastic hood, ferrite core
Test Report ------------------------------------------------------------------------------- 6/26
Report No.: M4715061017 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Chapter 2 Conducted Emission Test Test condition and setup All the equipment is placed and setup according to CISPR 22.
Mains power: The EUT is assembled on a wooden table, which is 80 cm high and placed 40 cm from the
back-wall, which is a vertical conducting plane. One LISN is for EUT, the other LISN is for support equipment. They are all placed on the conductive ground. The EUT’s LISN connect a line switch box for selecting L1 or L2, then connect to a preamplifier and receiver.
The spectrum scans from 150KHz to 30MHz. Conducted emission levels are detected at maximum peak mode. But if the maximum peak mode failed or over average limit, it will be measured by average detection mode.
While testing the worst-emission plot printed in the peak detection mode, and there are up to 6 highest emissions to be recorded. The plot is kept as the original data and not included in the test report.
Test Report ------------------------------------------------------------------------------- 7/26
Report No.: M4715061017 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
List of test Instrument
Calibration Date
Instrument Name Model Brand Serial No. Next time
Receiver
SCR3102 SCHAFFNER 012 12/09/07
LISN (EUT)
3825/2 EMCO 9411-2284 08/18/07
LISN (Support E.)
3825/2 EMCO 9210-2007 08/18/07
Pre-amplifier
CB-001 TRC 98-02 05/28/07
Line Switch Box
CB-01 TRC 98-04 05/28/07
FTB-1-6 Attenuator
15542 Mini – Circuits
9620 03 05/28/07
20dB Attenuator
CAT-20 Mini – Circuits
9620 13 05/28/07
Coaxial Cable
BNC3200B-0058 JYEBAO CL-05 05/28/07
Coaxial Cable
BNC31VB-0316 JYEBAO IF-01CA0069-036
05/28/07
50 Ohm Terminator
370BNM NARDA PWR5W 07/20/07
50 Ohm Terminator
370BNM NARDA PWR5W 07/20/07
50 Ohm Terminator
370BNM NARDA PWR5W 09/02/07
50 Ohm Terminator
370BNM NARDA PWR5W 09/02/07
The level of confidence of 95%, the uncertainty of measurement of conducted emission is +3.10dB / -4.84dB.
Test Result: Pass (Appendix A)
Test Report ------------------------------------------------------------------------------- 8/26
Report No.: M4715061017 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Conducted Test Placement: (Front view and Side view)
Test Report ------------------------------------------------------------------------------- 9/26
Report No.: M4715061017 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Chapter 3 Radiated Emission Test Test condition and setup Pretest:
Prior to the final test (OATS test), the EUT is placed in an anechoic chamber, and scan from 30MHz to 1GHz. This is done to ensure the radiation is exactly emitted from the EUT.
Final test: Final radiation measurements are made on a 10–meter, open-field test site (FCC
Registration Number: 91035, Expiration date: 08/30/2008) The EUT is placed on a nonconductive table, which is 0.8m height, the top surface is 1.0 x
1.5 meter. The entire placement is according to EN 55022. The spectrum is examined from 30MHz to 1GHz measured by HP spectrum. The whole range antenna is used to measure frequency from 30MHz to 1GHz.
The final test is used the spectrum analyzer. Measure more than six top marked frequencies generated form pretest by computer step by step at each frequency. The EUT is rotated 360 degrees, and antenna is raised and lowered from 1 to 4 meters to find the maximum emission levels. The antenna is used with both horizontal and vertical polarization. Appropriated preamplifier which is made by TRC is used for improving sensitivity and precautions is taken to avoid overloading .The spectrum analyzer’s 6dB bandwidth is set to 120kHz, and the EUT is measured at quasi-peak (below 1GHz) mode. If the emission is close to the frequency band of ambient, the tester will recheck the data and the corrected data will be written in the test data sheet. If the emission is just within the ambient, the data from shielded room will be taken as the final data.
Test Report ------------------------------------------------------------------------------- 10/26
Report No.: M4715061017 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
List of test Instrument
Calibration Date
Instrument Name Model Brand Serial No. Next time
EMI Receiver 8546A HP 3520A00242 09/06/07
RF Filter Section 85460A HP 3448A00217 09/06/07
Small Biconical Antenna
UBAA9114 & BBVU9135
SCHWARZECK 127 12/07/07
Pre-amplifier PA1F TRC 1FAC 05/20/07
Auto Switch Box (>30MHz)
ASB-01 TRC 9904-01 05/20/07
Coaxial Cable (Double shielded, 15 meter)
A30A30-0058-50FS-15M JYEBAO SMA-08 05/20/07
Coaxial Cable (1.1 meter)
A30A30-0058-50FS-1M JYEBAO SMA-02 05/20/07
Receiver SCR3102 SCHAFFNER 012 12/08/07
Control Box TWR95-4 TRC C9001-2 N/A
Antenna VULB 9160 SCHWARZECK 3063 05/31/07
Pre-amplifier TRC-CB-2 TRC CB-002 05/26/07
Coaxial cable (20 meter)
RG-214/U JYEBAO Cl-002 05/28/07
Coaxial Cable (50 cm)
BNC31VB-0316 JYEBAO SMA-02 05/28/07
Coaxial Cable (1.1 meter)
BNC31VB-0318 JYEBAO SMA-02 05/28/07
Coaxial Cable (1.1 meter)
BNC31VB-0316 JYEBAO SMA-02 05/28/07
Coaxial Cable (1.1 meter)
BNC31VB-0316 JYEBAO SMA-02 05/28/07
The level of confidence of 95% , the uncertainty of measurement of radiated emission is +2.85dB / -2.77dB .
Test Result: Pass (Appendix B)
Test Report ------------------------------------------------------------------------------- 11/26
Report No.: M4715061017 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Radiated Test Placement: (Front view and Rear view)
Test Report ------------------------------------------------------------------------------- 12/26
Report No.: M4715061017 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Appendix A Test Result of Conducted Emissions for Mains power
Testing room : Temperature : 25 ° C Humidity : 73 % RH Line 1
READING AMPLITUDE LIMIT Frequency
(kHz) Peak
(dBµV) Quasi-Peak
(dBµV) Average (dBµV)
Quasi-Peak(dBµV)
Average (dBµV)
Margin
(dB)
201.000 45.17 --- --- 79.00 66.00 -20.83492.000 43.45 --- --- 79.00 66.00 -22.55589.000 44.47 --- --- 73.00 60.00 -15.53788.000 41.07 --- --- 73.00 60.00 -18.93
1274.000 40.35 --- --- 73.00 60.00 -19.653120.000 38.50 --- --- 73.00 60.00 -21.506860.000 39.79 --- --- 73.00 60.00 -20.21
15780.000 39.81 --- --- 73.00 60.00 -20.1926630.000 44.34 --- --- 73.00 60.00 -15.66
Line 2 READING AMPLITUDE LIMIT
Frequency (kHz)
Peak (dBµV)
Quasi-Peak(dBµV)
Average (dBµV)
Quasi-Peak(dBµV)
Average (dBµV)
Margin
(dB)
206.000 48.58 --- --- 79.00 66.00 -17.42303.000 37.29 --- --- 79.00 66.00 -28.71594.000 33.88 --- --- 73.00 60.00 -26.12
1672.000 33.49 --- --- 73.00 60.00 -26.513120.000 34.36 --- --- 73.00 60.00 -25.646880.000 38.30 --- --- 73.00 60.00 -21.70
15780.000 43.17 --- --- 73.00 60.00 -16.8322450.000 41.91 --- --- 73.00 60.00 -18.0927180.000 42.86 --- --- 73.00 60.00 -17.14
Note: 1. The reading amplitudes are all under limit. 2. Testing result = Amplitude reading + Correction factor (Insertion loss of LISN, Cable loss,
Attenuator, Amplifier and so on)
Test Report ------------------------------------------------------------------------------- 13/26
Report No.: M4715061017 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Appendix B Test Conditions: Testing room : Temperature : 25 ° C Humidity : 73 % RH Testing site : Temperature : 25 ° C Humidity : 73 % RH Test Result of Radiated Emission for Horizontal
Frequency Reading Amplitude
Ant. Height
Table
Correction Factors
Corrected Amplitude
Class A Limit
Margin
MHz dBµV m degree dB/m dBµV/m dBµV/m dB
125.0010 30.33 2.34 225 -4.95 25.38 40.00 -14.62
250.0030 43.71 2.12 223 -2.24 41.47 47.00 -5.53
367.2010 30.35 3.45 333 2.79 33.14 47.00 -13.86
500.0080 28.97 1.63 57 7.20 36.17 47.00 -10.83
561.0400 29.07 2.44 268 9.14 38.21 47.00 -8.79
960.0040 20.95 3.12 245 17.89 38.84 47.00 -8.16 Test Result of Radiated Emission for Vertical
Frequency Reading Amplitude
Ant. Height
Table
Correction Factors
Corrected Amplitude
Class A Limit
Margin
MHz dBµV m degree dB/m dBµV/m dBµV/m dB
125.0020 30.77 1.01 257 -4.95 25.82 40.00 -14.18
250.0120 40.55 1.01 223 -2.24 38.31 47.00 -8.69
500.0080 24.47 1.01 47 7.20 31.67 47.00 -15.33
561.0520 29.10 1.01 201 9.14 38.24 47.00 -8.76
960.0030 20.63 1.01 241 17.89 38.52 47.00 -8.48
Note: 1. Margin = Amplitude – limit, if margin is minus means under limit. 2. Corrected Amplitude = Reading Amplitude + Correction Factors 3. Correction factor = Antenna factor + (Cable Loss – Amplitude gain) + Switching Box Loss
Test Report ------------------------------------------------------------------------------- 14/26
Report No.: M4715061017 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Appendix C
Photographs of EUT
External Photos of EUT ------------------------------------------------------------ 15/26
External Photos of EUT ------------------------------------------------------------ 16/26
Power Supply of EUT --------------------------------------------------------------- 17/26
Power Supply of EUT --------------------------------------------------------------- 18/26
Power Supply of EUT --------------------------------------------------------------- 19/26
Power Supply of EUT --------------------------------------------------------------- 20/26
Power Supply of EUT --------------------------------------------------------------- 21/26
Internal Photos of EUT ------------------------------------------------------------- 22/26
Internal Photos of EUT ------------------------------------------------------------- 23/26
Internal Photos of EUT ------------------------------------------------------------- 24/26
Test Report ------------------------------------------------------------------------------- 25/26
Report No.: M4715061017 Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Appendix D
LABEL Information of EUT
LABEL Sample and Location information -------------------------------------- 26/26
LABEL Format: LABEL Size: 20 x 50 mm LABEL Position:
Trade Name Model Number
This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation