This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory
quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
CERTIFICATE OF ACCREDITATION ANSI National Accreditation Board
11617 Coldwater Road, Fort Wayne, IN 46845 USA
This is to certify that
Keysight Technologies Taiwan LTD. Calibration Laboratory No. 20, Kao-Shuang Road
Ping-Chen district 32450, Tao-Yuan City, Taiwan R.O.C. has been assessed by ANAB and meets the requirements of international standard
ISO/IEC 17025:2017 and national standards
ANSI/NCSL Z540-1-1994 (R2002) and ANSI/NCSL Z540.3-2006 (R2013)
while demonstrating technical competence in the field of
CALIBRATION Refer to the accompanying Scope of Accreditation for information regarding the types of
activities to which this accreditation applies
AC-1928.01 Certificate Number
Certificate Valid Through: 03/11/2022
Version No. 006 Issued: 02/27/2020
Version 006
Issued: February 27, 2020 www.anab.org
Page 1 of 29
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017, ANSI/NCSL Z540-1-1994 (R2002) AND ANSI/NCSL Z540.3-2006 (R2013)
Keysight Technologies Taiwan LTD. Calibration Laboratory
No. 20, Kao-Shuang Road Ping-Chen district 32450, Tao-Yuan City, Taiwan R.O.C.
Freddy Hsu Phone: +886 3 4959389 [email protected] www.keysight.com
CALIBRATION
Valid to: March 11, 2022 Certificate Number: AC-1928.01
Electrical – RF/Microwave
Parameter/Equipment Range Expanded Uncertainty of Measurement (+/-)
Reference Standard, Method, and/or
Equipment
Signal Analyzers – Relative RF Power
in Coaxial Line
(0 to 70) dB (70 to 110) dB
Max power level: 10 dBm 50 MHz to 2 GHz
0.013 dB 0.04 dB
Signal Source E8257D, Step Attenuators
Direct measurement
Signal Analyzers – Phase Noise
Carrier frequency: 1 GHz Offset frequency: 100 Hz to 10 MHz
0.36 dB
Signal Source 500-13438
Source phase noise: -107 to -167 dBc/Hz Direct measurement
Power Sensor – Calibration Factors
9 kHz to < 100 MHz 100 MHz
(>0.1 to 4.2) GHz (>4.2 to 8) GHz (>8 to 17) GHz
(>17 to 26.5) GHz (>26.5 to 33) GHz (>33 to 37) GHz (>37 to 40) GHz (>40 to 44) GHz (>44 to 50) GHz
0.7 % cal factor 0.6 % cal factor 0.7 % cal factor 1 % cal factor
1.1 % cal factor 1.5 % cal factor 1.6 % cal factor 2.4 % cal factor 2.3 % cal factor 3.5 % cal factor 3.3 % cal factor
Power Sensor 8481A, 8482A, 8485A, 8487A and
E9304A
Passive Devices Scattering Parameter: Reflection
coefficient (linear) 9 kHz to 50 GHz (See Matrix A)
Measure using E5071C and N5230C Network Analyzer
Direct Measurement
Version 006
Issued: February 27, 2020 www.anab.org
Page 2 of 29
Electrical – RF/Microwave
Parameter/Equipment Range Expanded Uncertainty of Measurement (+/-)
Reference Standard, Method, and/or
Equipment
Passive Devices Scattering Parameter: Transmission
coefficient 9 kHz to 50 GHz (See Matrix B)
Measure using E5071C, N5230C, N5245A, and
E8363C Network Analyzer Direct Measurement
Signal Sources – Absolute RF Power in
Coaxial 9 kHz to 50 GHz (See Matrix C)
Direct measurement Power Sensor Power Meter
Absolute RF Power in Coaxial Line 9 kHz to 50 GHz (See Matrix D)
Signal Sources, Power Splitters, Power Meters,
Power Sensors Direct measurement
Signal Sources – Harmonic Content
Fundamental Frequency 1 MHz to 25 GHz
(0 to 10) dBm Harmonic Frequency
2 MHz to 50 GHz (-110 to 0) dBm
0.51 dB
yzer E4448A Direct measurement
Signal Sources – Pulse Time Parameters
Rise/Fall Time
(0 to 10) dBm 10 MHz to 50 GHz
18 ps to 10 ns 86 ps
Oscilloscope mainframe 86100C, Electrical module
86117A. Direct measurement
Signal Sources –Modulation
Frequency Modulation
Peak Frequency Deviation
(-18 to 30) dBm fc: 250 kHz to 10 MHz
fm: 20 Hz to 10 kHz Δf: 200 Hz to 40 kHz
β> 0.2 fc: 250 kHz to 10 MHz
fm: 20 Hz to 10 kHz Δf: 200 Hz to 40 kHz
β> 1.2 fc: 10 MHz to 6.6 GHz fm: 50 Hz to 200 kHz Δf: 250 Hz to 400 kHz
β> 0.2 fc: 10 MHz to 6.6 GHz fm: 50 Hz to 200 kHz Δf: 250 Hz to 400 kHz
β> 0.45
0.015 Hz/Hz
0.01 Hz/Hz
0.015 Hz/Hz
0.01 Hz/Hz
Signal analyzer E4448A fc = Carrier Frequency fm = Modulation Rate Δf=Peak Deviation
β = Δf / fm Direct measurement
Version 006
Issued: February 27, 2020 www.anab.org
Page 3 of 29
Electrical – RF/Microwave
Parameter/Equipment Range Expanded Uncertainty of Measurement (+/-)
Reference Standard, Method, and/or
Equipment
Signal Sources –Modulation
Frequency Modulation
Peak Frequency Deviation
(-18 to 30) dBm fc: 6.6 GHz to 13.2 GHz
fm: 50 Hz to 200 kHz Δf: 250 Hz to 400 kHz
β> 0.2
fc: 6.6 GHz to 13.2 GHz fm: 50 Hz to 200 kHz
Δf: 250 Hz to 400 kHz β> 8
fc: (13.2 to 31.15) GHz fm: 50 Hz to 200 kHz
Δf: 250 Hz to 400 kHz β> 0.2
fc: (13.2 to 31.15) GHz fm: 50 Hz to 200 kHz
Δf: 250 Hz to 400 kHz β> 16
fc: (31.15 to 50) GHz fm: 50 Hz to 200 kHz
Δf: 250 Hz to 400 kHz β> 0.2
fc: (31.15 to 50) GHz fm: 50 Hz to 200 kHz
Δf: 250 Hz to 400 kHz β> 32
0.025 Hz/Hz
0.01 Hz/Hz
0.038 Hz/Hz
0.01 Hz/Hz
0.85 Hz/Hz
0.01 Hz/Hz
Signal analyzer E4448A fc = Carrier Frequency fm = Modulation Rate Δf=Peak Deviation
β = Δf / fm Direct measurement
Version 006
Issued: February 27, 2020 www.anab.org
Page 4 of 29
Electrical – RF/Microwave
Parameter/Equipment Range Expanded Uncertainty of Measurement (+/-)
Reference Standard, Method, and/or
Equipment
Signal Sources –
Amplitude Modulation
Depth
-18 to 30 dBm fm: 50 Hz to 100 kHz
fc: 100 kHz to 10 MHz
Depth: 5 % to 99 %
fc: 10 MHz to 3 GHz Depth: 20 % to 99 %
fc: 10 MHz to 3 GHz Depth: 5 % to 20 %
fc: (3 to 26.5) GHz
Depth: 20 % to 99 %
-18 to 30 dBm fm: 50 Hz to 100 kHz
fc: (3 to 26.5) GHz Depth: 5 % to 20 %
fc: (26.5 to 31.15) GHz Depth: 20 % to 99 %
fc: (26.5 to 31.15) GHz
Depth: 5 % to 20 %
fc: (31.15 to 50) GHz Depth: 5 % to 20 %
fc: (31.15 to 50) GHz Depth: 5 % to 20 %
0.007 5 %/% Depth
0.005 %/% Depth
0.025 %/% Depth
0.015 %/% Depth
0.045 %/% Depth
0.019 %/% Depth
0.068 %/% Depth
0.06 %/% Depth
0.26 %/% Depth
Signal analyzer E4448A fc = Carrier Frequency fm = Modulation Rate Direct measurement
Version 006
Issued: February 27, 2020 www.anab.org
Page 5 of 29
Electrical – RF/Microwave
Parameter/Equipment Range Expanded Uncertainty of Measurement (+/-)
Reference Standard, Method, and/or
Equipment
Phase Modulation
Peak phase deviation
-18 to 30 dBm fc: 100 kHz to 6.6 GHz
ΔΦ > 0.7 rad
fc: 100 kHz to 6.6 GHz ΔΦ > 0.3 rad
fc: (6.6 to 13.2) GHz
ΔΦ > 2.0 rad
fc: (6.6 to 13.2) GHz ΔΦ > 0.6 rad
fc: (13.2 to 26.5) GHz
ΔΦ > 4.0 rad
fc: (13.2 to 26.5) GHz ΔΦ > 1.2 rad
fc: (26.5 to 31.15) GHz
ΔΦ > 4.0 rad
-18 to 30 dBm
fc: (26.5 to 31.15) GHz ΔΦ > 1.3 rad
fc: (31.15 to 50) GHz
ΔΦ > 8 rad
fc: (31.15 to 50) GHz ΔΦ > 2.4 rad
0.01 rad/rad
0.03 rad/rad
0.01 rad/rad
0.03 rad/rad
0.01 rad/rad
0.03 rad/rad
0.01 rad/rad
0.03 rad/rad
0.01 rad/rad
0.01 rad/rad
Signal analyzer E4448A fc = Carrier Frequency ΔΦ = Phase Deviation
Direct measurement
Version 006
Issued: February 27, 2020 www.anab.org
Page 6 of 29
Electrical – RF/Microwave
Parameter/Equipment Range Expanded Uncertainty of Measurement (+/-)
Reference Standard, Method, and/or
Equipment Phase Modulation
Modulation Rate
Amplitude Modulation Rate
Frequency Modulation Rate
Phase Modulation Rate
-18 to 30 dBm 100 kHz ≤ fc< 50 GHz
Depth ≥ 20% fm ≤ 100 kHz
β ≥ 0.01
fm ≤ 200 kHz
β ≥ 0.01 fm ≤ 20 kHz
0.062 Hz
0.062 Hz
0.062 Hz
Signal analyzer E4448A β = Δf / fm
fm = Modulation Rate Direct measurement
Signal Sources – Modulation Distortion
Amplitude Modulation
Distortion
0.01% to 100%
fm: 20 Hz to 1 kHz fc: 100 kHz to 10 MHz
Depth: > 1 % Depth: > 3 %
fm: 20 Hz to 1 kHz
fc: 10 MHz to 26.5 GHz Depth: > 1 % Depth: > 3 %
fm: 20 Hz to 1 kHz
fc: (26.5 to 50) GHz Depth: > 1 % Depth: > 3 % Depth: > 5 %
0.8 % Depth 0.3 % Depth
1 % Depth 0.4 % Depth
6.2 % Depth 2 % Depth
1.5 % Depth
Signal analyzer E4448A fc =Carrier Frequency fm = Modulation Rate Direct measurement
Signal Sources –
Phase Modulation Distortion
0.01% to 100%
fc: 1 MHz to 6.6 GHz fm: (20 to 500) Hz
ΔΦ > 0.8 rad ΔΦ ≥ 2.5 rad
fc: 1 MHz to 6.6 GHz fm: 500 Hz to 1 kHz
ΔΦ> 0.4 rad ΔΦ ≥ 1.0 rad
0.3 % of reading 0.1 % of reading
0.3 % of reading 0.1 % of reading
Signal analyzer E4448A fc =Carrier Frequency fm = Modulation Rate Direct measurement
Version 006
Issued: February 27, 2020 www.anab.org
Page 7 of 29
Electrical – RF/Microwave
Parameter/Equipment Range Expanded Uncertainty of Measurement (+/-)
Reference Standard, Method, and/or
Equipment
Signal Sources –
Phase Modulation Distortion
0.01% to 100%
fc: (6.6 to 13.2) GHz fm: (20 to 500) Hz
ΔΦ > 1.8 rad ΔΦ ≥ 5.5 rad
fc: (13.2 to 31.15) GHz
fm: (20 to 500) Hz ΔΦ > 3.5 rad ΔΦ ≥ 10.0 rad
0.01% to 100%
fc: (13.2 to 31.15) GHz
fm: 500 Hz to 1 kHz ΔΦ > 1.2 rad ΔΦ ≥ 4.0 rad
fc: (31.15 to 50) GHz
fm: (20 to 500) Hz ΔΦ > 7.5 rad ΔΦ ≥ 19.0 rad
fc: (31.15 to 50) GHz fm: 500 Hz to 1 kHz
ΔΦ > 3.0 rad ΔΦ ≥ 8.0 rad
0.3 % of reading 0.1 % of reading
0.3 % of reading 0.1 % of reading
0.3 % of reading 0.1 % of reading
0.3 % of reading 0.1 % of reading
0.3 % of reading 0.1 % of reading
Signal analyzer E4448A fc =Carrier Frequency fm = Modulation Rate Direct measurement
PARAMETER/ EQUIPMENT MODULATION TYPES FREQUENCY RANGE
Digital Modulation RF Quality1
Measure – Carrier 2 MHz to 44 GHz
TETRA, PDC, NADC, PHS, EDGE, CDMA 2000A/C, WCDMA, 3GPP, QPSK, BPSK, PI/4
DQPSK, 16QAM, 256QAM, DECT, PHP, GSM, 2FSK, 4FSK, GMSK, MSK, DQPSK, 8PSK,
32QAM FSK
2 MHz to 2.65 GHz using the VSA directly (2.65 to 44) GHz.
The digitally modulated RF signal needs to be down-converted with an external Mixer
and a Local Oscillator L.O. center frequency = 150 MHz
Version 006
Issued: February 27, 2020 www.anab.org
Page 8 of 29
Electrical – RF/Microwave
Parameter/Equipment Range Expanded Uncertainty of Measurement (+/-)
Reference Standard, Method, and/or
Equipment
Signal Sources –
Digital Modulation Carrier: 2 MHz to 2.65 GHz
Error Vector Magnitude
(EVM)
Phase Error
Frequency Error
Mod Frequency Span: f ≤ 100kHz
100kHz ≤ f ≤ 1MHz f > 1MHz
Up to 180 °
Mod Frequency Span: f ≤ 100kHz
100kHz ≤ f ≤ 1MHz f > 1MHz
Mod Frequency
1 GHz 2 GHz 3 GHz 4 GHz 5 GHz 6 GHz
0.43 % of reading 0.48 % of reading 0.82 % of reading
0.17 º rms 0.34 º rms 0.57 º rms
0.063 % of reading 0.068 % of reading 0.079 % of reading 0.099 % of reading 0.33 % of reading 0.39 % of reading
HP 89441A Vector Signal Analyzer
Modulation Types:
TETRA, PDC, NADC, PHS, EDGE, CDMA
2000A/C, WCDMA, 3GPP, QPSK, BPSK, PI/4 DQPSK, 16QAM,
256QAM, DECT, PHP, GSM,
2FSK, 4FSK, GMSK, MSK, DQPSK, 8PSK,
32QAM FSK
Frequency Range: 2 MHz to 2.65 GHz using
the VSA directly (2.65 to 44)
GHz. The digitally modulated RF
signal needs to be down-converted with an
external Mixer and a Local Oscillator
L.O. center frequency = (RF-150 MHz)
Version 006
Issued: February 27, 2020 www.anab.org
Page 9 of 29
Electrical – RF/Microwave
Parameter/Equipment Range Expanded Uncertainty of Measurement (+/-)
Reference Standard, Method, and/or
Equipment
Modulation Accuracy (Rho)
Mod Frequency Span: f ≤ 100kHz
0.9999 ≤ ρ ≤ 1 0.9975 ≤ρ < 0.9999 0.9936 ≤ρ < 0.9975 0.99 ≤ρ < 0.9936 0.978 ≤ρ < 0.99 0.96 ≤ρ < 0.978
Mod Frequency Span: 100 kHz ≤ f ≤ 1 MHz
0.9999 ≤ρ ≤ 1 0.9975 ≤ρ < 0.9999 0.9936 ≤ρ 0.9975 0.99 ≤ρ < 0.9936 0.978 ≤ρ < 0.99 0.96 ≤ρ < 0.978
Mod Frequency Span:
f > 1MHz 0.9999 ≤ρ ≤ 1
0.9975 ≤ρ < 0.9999 0.9936 ≤ρ < 0.9975 0.99 ≤ρ < 0.9936 0.978 ≤ρ < 0.99 0.96 ≤ρ < 0.978
8.6E-5 ρ 0.000 43 ρ 0.000 68 ρ 0.000 84 ρ 0.001 2 ρ 0.001 6 ρ
9.6E-5 ρ 0.000 48 ρ 0.000 76 ρ 0.000 94 ρ 0.001 4 ρ 0.001 8 ρ
1.6E-4 ρ 0.000 82 ρ 0.001 3 ρ 0.001 6 ρ 0.002 4 ρ 0.003 ρ
HP 89441A Vector Signal Analyzer
Modulation Types:
TETRA, PDC, NADC, PHS, EDGE, CDMA
2000A/C, WCDMA, 3GPP, QPSK, BPSK, PI/4 DQPSK, 16QAM,
256QAM, DECT, PHP, GSM,
2FSK, 4FSK, GMSK, MSK, DQPSK, 8PSK,
32QAM FSK
Frequency Range: 2 MHz to 2.65 GHz using
the VSA directly (2.65 to 44)
GHz. The digitally modulated RF
signal needs to be down-converted with an
external Mixer and a Local Oscillator
L.O. center frequency = (RF-150 MHz)
Signal Sources –
Frequency Modulation Distortion
(0.01 to 100) % fc: (6.6 to 13.2) GHz fm: 20 Hz to 1 kHz
Δf> 2.3 kHz Δf ≥ 4.5 kHz
fc: (13.2 to 31.15) GHz fm: 20 Hz to 1 kHz
Δf> 2.7 kHz Δf ≥ 6.0 kHz
fc: (31.15 to 50) GHz fm: 20 Hz to 1 kHz
Δf> 4.0 kHz Δf ≥ 12.0 kHz
0.3 % of reading 0.1 % of reading
0.3 % of reading 0.1 % of reading
0.3 % of reading 0.1 % of reading
Signal analyzer E4448A fc =Carrier Frequency fm = Modulation Rate Direct measurement
Version 006
Issued: February 27, 2020 www.anab.org
Page 10 of 29
Electrical – RF/Microwave
Parameter/Equipment Range Expanded Uncertainty of Measurement (+/-)
Reference Standard, Method, and/or
Equipment
Signal Sources –
Frequency Modulation Distortion
(0.01 to 100) % fc: 1 MHz to 6.6 GHz
fm: 20 Hz to 1 kHz Δf: 500 Hz to 2 kHz
Δf ≥ 2.0 kHz
0.3 % of reading 0.1 % of reading
Signal analyzer E4448A fc =Carrier Frequency fm = Modulation Rate Direct measurement
Phase Noise for Signal Sources
Offset Frequency ≤ 100 kHz ≤ 100 kHz ≤ 1 MHz ≤ 10 MHz
< 100 MHz
Offset Frequency ≤ 100 kHz ≤ 100 kHz ≤ 1 MHz ≤ 10 MHz
< 100 MHz
Offset Frequency ≤ 100 kHz ≤ 100 kHz ≤ 1 MHz ≤ 10 MHz
< 100 MHz
Offset Frequency ≤ 100 kHz ≤ 100 kHz ≤ 1 MHz ≤ 10 MHz
< 100 MHz
LREF - LDUT) ≥ 10dB ≤ 100 MHz
100 MHz < f ≤ 26.5 GHz 50 kHz < f ≤ 26.5 GHz 50 kHz < f ≤ 26.5 GHz 50 kHz < f ≤ 26.5 GHz
10dB > (LREF - LDUT) ≥
5dB ≤ 100 MHz
100 MHz < f ≤ 26.5 MHz 50 kHz < f ≤ 26.5 GHz 50 kHz < f ≤ 26.5 GHz 50 kHz < f ≤ 26.5 GHz
5dB > (LREF - LDUT) ≥
3dB ≤ 100 MHz
100 MHz < f ≤ 26.5G Hz 50 kHz < f ≤ 26.5 GHz 50 kHz < f ≤ 26.5 GHz 50 kHz < f ≤ 26.5 GHz
3dB > (LREF - LDUT) ≥
0dB ≤ 100 MHz
100 MHz < f ≤ 26.5 GHz 50 kHz < f ≤ 26.5 GHz 50 kHz < f ≤ 26.5 GHz 50 kHz < f ≤ 26.5 GHz
2.3 dB 2.3 dB 2.3 dB 4.6 dB 4.6 dB
2.8 dB 2.9 dB 2.9 dB 5.2 dB 5.3 dB
3.2 dB 3.3 dB 3.3 dB 5.4 dB 5.5 dB
4.3 dB 4.3 dB 4.3 dB 6.1 dB 6.2 dB
Keysight E5505A Phase Noise System
Version 006
Issued: February 27, 2020 www.anab.org
Page 11 of 29
Electrical – RF/Microwave
Parameter/Equipment Range Expanded Uncertainty of Measurement (+/-)
Reference Standard, Method, and/or
Equipment Phase Noise for Signal
Sources Offset Frequency
≤ 100 kHz ≤ 100 kHz ≤ 100 kHz ≤ 100 kHz ≤ 100 kHz ≤ 100 kHz ≤ 100 kHz ≤ 100 kHz ≤ 1 MHz ≤ 10 MHz
< 100 MHz
dB > (LREF - LDUT) ≥ 0
dB ≤ 100 MHz
100 MHz < f ≤ 255 MHz 255 MHz < f ≤ 600 MHz 600 MHz < f ≤ 1.8 GHz 1.8 GHz < f ≤ 3.2 GHz 3.2 GHz < f ≤ 10 GHz 10 GHz < f ≤ 20 GHz
20 GHz < f ≤ 26.5 GHz 50 kHz < f ≤ 26.5 GHz 50 kHz < f ≤ 26.5 GHz 50 kHz < f ≤ 26.5 GHz
4.3 dB 4.6 dB 4.6 dB 4.5 dB 4.5 dB 4.8 dB .8 dB 4.5 dB 4.7 dB 6.2 dB 6.2 dB
Keysight E5505A Phase Noise System
Power Sources Fitted with female Type-N
connectors 1 mW at 50 MHz 3.1 µW
Thermistor Mount 478A Direct measurement
(1 mW 50 MHz Reference Source Calibration)
Version 006
Issued: February 27, 2020 www.anab.org
Page 12 of 29
Matrix A Passive Devices Scattering Parameter: Reflection coefficient
Frequency (S11 - Reflection) Measured Magnitude (+/- dB)
< 0.1 > 0.1 to ≤ 0.2
> 0.2 to ≤ 0.3
> 0.3 to ≤ 0.4
> 0.4 to ≤ 0.5
> 0.5 to ≤ 0.6
> 0.6 to ≤ 0.7
> 0.7 to ≤ 0.8
> 0.8 to ≤ 0.9
9 kHz to 10 MHz 0.003 8 0.003 9 0.004 0.004 3 0.004 8 0.005 4 0.005 8 0.007 4 0.008 7 Using E5071C with 85032F Calibration
Kit
(0.01 to 3) GHz 0.005 2 0.005 3 0.005 4 0.005 7 0.006 1 0.006 8 0.007 2 0.008 8 0.01 (3 to 6) GHz 0.01 0.01 0.01 0.011 0.011 0.012 0.013 0.015 0.017
(6 to 8.5) GHz 0.013 0.013 0.013 0.013 0.014 0.015 0.015 0.018 0.02 (0.045 to1) GHz 0.004 2 0.004 3 0.004 4 0.004 6 0.004 8 0.005 1 0.005 4 0.006 2 0.006 9 Using N5230C,
E8364B with 85054B Calibration Kit
(1 to 6) GHz 0.004 2 0.004 3 0.004 4 0.004 6 0.004 8 0.005 2 0.005 4 0.006 2 0.006 9 (6 to 18) GHz 0.008 0.008 1 0.008 3 0.008 6 0.009 1 0.01 0.011 0.013 0.015
(0.045 to 6) GHz 0.004 2 0.004 2 0.004 4 0.004 7 0.005 2 0.005 9 0.006 3 0.008 0.009 5 Using N5230C, E8364B with 85052B
Calibration Kit (6 to 20) GHz 0.006 4 0.006 5 0.006 8 0.007 5 0.008 7 0.011 0.012 0.016 0.019
(0 to 26.5) GHz 0.006 5 0.006 7 0.007 2 0.008 2 0.009 9 0.012 0.014 0.019 0.024 (0.045 to 20) GHz 0.008 1 0.008 2 0.008 2 0.008 4 0.008 6 0.008 9 0.009 1 0.01 0.011 Using N5230C,
E8364B with 85056A Calibration Kit
(20 to 40) GHz 0.013 0.013 0.013 0.014 0.014 0.016 0.016 0.02 0.022 (40 to 50) GHz 0.016 0.016 0.017 0.017 0.018 0.019 0.02 0.024 0.028
Frequency (S11 - Reflection) Measured Phase (+/- Degree)
< 0.1 > 0.1 to ≤ 0.2
> 0.2 to ≤ 0.3
> 0.3 to ≤ 0.4
> 0.4 to ≤ 0.5
> 0.5 to ≤ 0.6
> 0.6 to ≤ 0.7
> 0.7 to ≤ 0.8
> 0.8 to ≤ 0.9
9 kHz to 10 MHz 2.1 1.1 0.75 0.61 0.54 0.51 0.51 0.53 0.55 Using E5071C with 85032F Calibration
Kit
(0.01 to 3) GHz 2.9 1.5 1 0.81 0.7 0.65 0.63 0.63 0.65 (3 to 6) GHz 5.8 2.9 2 1.5 1.3 1.1 1.1 1.1 1.1
(6 to 8.5) GHz 7.3 3.7 2.5 1.9 1.6 1.4 1.37 1.3 1.3 (0.045 to1) GHz 1.6 0.97 0.72 0.59 0.52 0.47 0.46 0.44 0.44 Using N5230C,
E8364B with 85054B Calibration Kit
(1 to 6) GHz 1.6 0.96 0.71 0.58 0.51 0.46 0.45 0.44 0.44
(6 to 18) GHz 3.1 1.9 1.4 1.1 0.99 0.93 0.92 0.94 0.97 (0.045 to 6) GHz 2.3 1.2 0.82 0.66 0.58 0.56 0.55 0.57 0.61 Using N5230C,
E8364B with 85052B Calibration Kit
(6 to 20) GHz 3.6 1.6 1.3 1.1 1 1 13 1.1 1.2 (0 to 26.5) GHz 3.7 1.9 1.4 1.2 1.1 1.2 1.2 1.4 1.5
(0.045 to 20) GHz 4.6 2.3 1.6 1.2 0.98 0.85 0.81 0.72 0.7 Using N5230C, E8364B with 85056A
Calibration Kit (20 to 40) GHz 7.4 3.7 2.5 1.9 1.6 1.5 1.4 1.4 1.4
(40 to 50) GHz 9.3 4.7 3.1 2.4 2.1 1.9 1.8 1.8 1.8
Version 006
Issued: February 27, 2020 www.anab.org
Page 13 of 29
Matrix B Passive Devices Scattering Parameter: Reflection coefficient
Frequency (S21 - Transmission) Measured Magnitude (+/- dB)
0-10 10-20 20-30 30-40 40-50 50-60 60-70 70-80 80-90 9 kHz to 10 MHz 0.029 0.039 0.048 0.064 0.086 0.111 0.147 0.219 0.355
Using E5071C with 85032F Calibration Kit
(0.01 to 3) GHz 0.031 0.04 0.049 0.065 0.086 0.11 0.144 0.199 0.3 (3 to 6) GHz 0.062 0.066 0.072 0.084 0.101 0.122 0.153 0.206 0.304
(6 to 8.5) GHz 0.092 0.096 0.1 0.109 0.122 0.14 0.168 0.217 0.313 (0.045 to 2) GHz 0.024 0.035 0.046 0.059 0.077 0.106 0.137 0.186 0.243 Using N5230C, N5245A,
E8363C with 85054B Calibration Kit
(2 to 4) GHz 0.044 0.058 0.065 0.073 0.084 0.106 0.14 0.18 0.244 (4 to 18) GHz 0.079 0.087 0.097 0.105 0.114 0.133 0.157 0.193 0.253
(0.045 to 6) GHz 0.024 0.035 0.046 0.06 0.077 0.106 0.137 0.186 0.243 Using N5230C, N5245A, E8363C with 85052B
Calibration Kit (6 to 20) GHz 0.052 0.064 0.071 0.078 0.089 0.11 0.143 0.181 0.242
(0 to 26.5) GHz 0.096 0.102 0.111 0.123 0.137 0.157 0.186 0.224 0.296 (0.045 to 20) GHz 0.024 0.035 0.047 0.061 0.078 0.106 0.137 0.186 0.243 Using N5230C, N5245A,
E8363C with 85056A Calibration Kit
(20 to 40) GHz 0.108 0.129 0.147 0.153 0.161 0.188 0.213 0.25 0.327 (40 to 50) GHz 0.184 0.193 0.2 0.208 0.219 0.235 0.27 0.381 0.566
Frequency (S21 - Transmission) Measured Phase (+/- Degree)
0-10 10-20 20-30 30-40 40-50 50-60 60-70 70-80 80-90 9 kHz to 10 MHz 0.193 0.254 0.317 0.424 0.571 0.756 1.011 1.543 2.868
Using E5071C with 85032F Calibration Kit
(0.01 to 3) GHz 0.205 0.263 0.325 0.429 0.573 0.755 0.979 1.402 2.292 (3 to 6) GHz 0.407 0.439 0.478 0.555 0.672 0.833 1.041 1.445 2.319
(6 to 8.5) GHz 0.613 0.634 0.662 0.719 0.813 0.95 1.138 1.52 2.386
(0.045 to 2) GHz 0.157 0.229 0.302 0.374 0.462 0.672 0.89 1.231 1.605 Using N5230C, N5245A, E8363C with 85054B
Calibration Kit (2 to 4) GHz 0.157 0.239 0.3 0.368 0.456 0.567 0.814 1.152 1.604
(4 to 18) GHz 0.289 0.375 0.42 0.474 0.548 0.679 0.919 1.173 1.611 (0.045 to 6) GHz 0.156 0.229 0.303 0.379 0.465 0.674 0.892 1.231 1.605 Using N5230C, N5245A,
E8363C with 85052B Calibration Kit
(6 to 20) GHz 0.189 0.421 0.461 0.51 0.58 0.706 0.939 1.189 1.622 (0 to 26.5) GHz 0.326 0.68 0.739 0.816 0.915 1.049 1.251 1.491 1.989
(0.045 to 20) GHz 0.161 0.232 0.306 0.386 0.471 0.678 0.895 1.231 1.605 Using N5230C, N5245A, E8363C with 85056A
Calibration Kit (20 to 40) GHz 0.639 0.679 0.738 0.815 0.914 1.051 1.252 1.491 1.99 (40 to 50) GHz 1.226 1.292 1.342 1.4 1.474 1.584 1.825 2.59 4.009
Version 006
Issued: February 27, 2020 www.anab.org
Page 14 of 29
Matrix C RF Absolute Power Measure ( 9 kHz to 12.4 GHz)
REFERENCE STANDARD OR
EQUIPMENT
Power Sensors E9304A, 8481A, 8482A, 8485A, 8487A, E9300A, N8482A, N8485A, N8488A
Frequency Ranges (uncertainties in dB)
Frequency Range
9 kHz ≤ f <
100 kHz
100 kHz ≤ f <
10 MHz
10 MHz ≤ f <
50 MHz
50 MHz ≤ f <
100 MHz
0.1 GHz ≤ f <
2 GHz
2 GHz ≤ f <
4.2 GHz
4.2 GHz ≤ f <
6 GHz
6 GHz ≤ f <
8 GHz
8 GHz ≤ f <
12.4 GHz -140 dBm ≤ P < -130 dBm 0.167 0.073 0.072 0.070 0.072 0.073 0.074 0.078 0.079
-130 dBm ≤ P < -110 dBm 0.16 0.067 0.064 0.061 0.063 0.065 0.068 0.071 0.072
-110 dBm ≤ P < -90 dBm 0.16 0.05 0.05 0.045 0.049 0.051 0.051 0.055 0.056
-90 dBm ≤ P < -30 dBm 0.16 0.041 0.04 0.035 0.04 0.042 0.042 0.046 0.047
-30 dBm ≤ P < -20 dBm 0.16 0.04 0.039 0.034 0.038 0.041 0.041 0.045 0.046
-20 dBm ≤ P < -10 dBm 0.13 0.04 0.038 0.032 0.037 0.04 0.04 0.044 0.045
-10 dBm ≤ P < -3 dBm 0.13 0.039 0.038 0.032 0.037 0.039 0.04 0.044 0.045
-3 dBm ≤ P < 3 dBm 0.027 0.027 0.028 0.02 0.024 0.024 0.031 0.036 0.037
3 dBm ≤ P < 10 dBm 0.058 0.035 0.031 0.024 0.03 0.033 0.033 0.038 0.039
10 dBm ≤ P < 15 dBm 0.097 0.04 0.036 0.03 0.035 0.038 0.038 0.042 0.044
15 dBm ≤ P < 20 dBm 0.1 0.046 0.046 0.041 0.046 0.048 0.049 0.051 0.061
20 dBm ≤ P < 30 dBm 0.156 0.16 0.16 0.15 0.16 0.16 0.16 0.161 0.16
Matrix C (cont) RF Absolute Power Measure (12.4 GHz to 67 GHz) REFERENCE
STANDARD OR EQUIPMENT
Power Sensors E9304A, 8481A, 8482A, 8485A, 8487A, E9300A, N8482A, N8485A, N8488A
Frequency Ranges (uncertainties in dB)
Frequency Range
12.4 GHz ≤ f <
14 GHz
14 GHz ≤ f <
18 GHz
18 GHz ≤ f ≤
24 GHz
24 GHz ≤ f <
26.5 GHz
26.5 GHz ≤ f <
33 GHz
33 GHz ≤ f ≤
40 GHz
40 GHz ≤ f ≤
50 GHz
50 GHz ≤ f ≤
60 GHz
60 GHz ≤ f ≤
67 GHz -140 dBm ≤ P < -130 dBm 0.077 0.078 0.078 0.096 0.1 0.11 0.12 0.14
-130 dBm ≤ P < -110 dBm 0.071 0.072 0.072 0.09 0.097 0.1 0.12 0.13
-110 dBm ≤ P < -90 dBm 0.056 0.057 0.057 0.077 0.085 0.093 0.11 0.13
-90 dBm ≤ P < -30 dBm 0.047 0.048 0.048 0.07 0.079 0.088 0.1 0.11 0.19
-30 dBm ≤ P < -20 dBm 0.046 0.047 0.047 0.069 0.079 0.087 0.1 0.11 0.1
-20 dBm ≤ P < -10 dBm 0.045 0.046 0.046 0.069 0.078 0.086 0.1 0.11 0.1
-10 dBm ≤ P < -3 dBm 0.045 0.046 0.046 0.068 0.078 0.086 0.1 0.11 0.1
-3 dBm ≤ P < 3 dBm 0.037 0.039 0.039 0.064 0.074 0.083 0.097 0.11 0.1
3 dBm ≤ P < 10 dBm 0.039 0.041 0.041 0.065 0.075 0.084 0.098 0.11 0.1
10 dBm ≤ P < 15 dBm 0.043 0.045 0.045 0.068 0.077 0.086 0.1 0.11 0.11
15 dBm ≤ P < 20 dBm 0.065 0.068 0.073 0.075 0.09 0.11 0.12 0.13 0.11
20 dBm ≤ P < 30 dBm 0.16 0.17 0.17 0.17
Version 006
Issued: February 27, 2020 www.anab.org
Page 15 of 29
Electrical – DC/Low Frequency
Parameter/Equipment Range Expanded Uncertainty of Measurement (+/-)
Reference Standard, Method, and/or
Equipment
DC voltmeter DCV source
(0 to 220) mV (0.22 to 2.2) V (2.2 to 11) V (11 to 22) V (22 to 220) V
(220 to 1 100) V
7.5 µV/V + 0.4 µV 5 µV/V + 0.7 µV
3.5 µV/V + 2.5 µV 3.5 µV/V + 4 µV 5 µV/V + 40 µV
6.5 µV/V + 400 µV
Multifunction calibrator Fluke 5730A
Direct Measurement
DC current meter DC current source
(0 to 220) μA (0.22 to 2.2) mA (2.2 to 22) mA (22 to 100) mA
(100 to 220) mA (0.22 to 1) A (1 to 2.2) A (2.2 to 5) A (5 to 10) A
40 µA/A + 6 nA 35 µA/A + 7 nA
35 µA/A + 40 nA 45 µA/A + 0.7 µA 50 uA/A - 1.2 uA 80 µA/A + 12 µA 120 uA/A - 42uA
360 µA/A + 480 µA 360 µA/A + 580 µA
Multifunction calibrator Fluke 5730A
Direct Measurement
Matrix D Signal Analyzers –Absolute RF Power in 50 Ω Coaxial Line
Frequency Range RF Power Level
(Uncertainty in mW/W) Power Sensor 10µW to 1nW 1nW to 500nW 500nW to 1µW
10 MHz to 18 GHz 20 9.8 9.8 8481D 50 MHz to 26.5 GHz 39 18 18 8485D 50 MHz to 50 GHz 38 15 15 8487D
Frequency Range
RF Power Level (Uncertainty in mW/W)
Power Sensor 1mW to
1µW
1µW to
100µW
100µW to
500µW
500µW to
700µW
700µW to
3mW
3mW to
6.31mW
100 kHz to 3 GHz 14 14 14 14 14 14 75 Ω Type N 8483A
100 kHz to 4.2 GHz 9.3 9.7 9.2 9.2 9.2 9.2 8482A 10 MHz to 18 GHz 9.4 10 9.4 9.4 9.4 9.2 8481A
50 MHz to 26.5 GHz 17 17 17 17 17 17 8485A 50 MHz to 50 GHz 16 16 16 16 16 16 8487A
Version 006
Issued: February 27, 2020 www.anab.org
Page 16 of 29
AC voltmeter AC volt source
(0.22 to 2.2) mV (10 to 20) Hz (20 to 40) Hz
40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz
(100 to 300) kHz (300 to 500) kHz
500 kHz to 1 MHz (2.2 to 22) mV
(10 to 20) Hz (20 to 40) Hz
40 Hz to 20 kHz (20 to 50) kHz
(50 to 100) kHz (100 to 300) kHz (300 to 500) kHz
500 kHz to 1 MHz (22 to 220) mV
(10 to 20) Hz (20 to 40) Hz
40 Hz to 20 kHz (20 to 50) kHz
(50 to 100) kHz (100 to 300) kHz (300 to 500) kHz
500 kHz to 1 MHz (0.22 to 2.2) V
(10 to 20) Hz (20 to 40) Hz
40 Hz to 20 kHz (20 to 50) kHz
(50 to 100) kHz (100 to 300) kHz (300 to 500) kHz
500 kHz to 1 MHz (2.2 to 22) V
(10 to 20) Hz (20 to 40) Hz
40 Hz to 20 kHz (20 to 50) kHz
(50 to 100) kHz (100 to 300) kHz (300 to 500) kHz
500 kHz to 1 MHz
240 µV/V + 4 µV 90 µV/V + 4 µV 80 µV/V + 4 µV 200 µV/V + 4 µV 500 µV/V + 5 µV 1.1 mV/V + 10 µV 1.4 mV/V + 20 µV 2.7 mV/V + 20 µV
240 µV/V + 4 µV 90 µV/V + 4 µV 80 µV/V + 4 µV 200 µV/V + 4 µV 500 µV/V + 5 µV 1.1 mV/V + 10 µV 1.4 mV/V + 20 µV 2.7 mV/V + 20 µV
240 µV/V + 12 µV 90 µV/V + 7 µV 57 µV/V + 7 µV 120 µV/V + 7 µV
310 µV/V + 17 µV 655 µV/V + 20 µV 1.4 mV/V + 25 µV 2.7 mV/V + 45 µV
240 µV/V + 40 µV 90 µV/V + 15 µV 42 µV/V + 8 µV 67 µV/V + 10 µV 85 µV/V + 30 µV
336 µV/V + 80 µV 1 mV/V + 200 µV
1.7 mV/V + 300 µV
240 µV/V + 400 µV 90 µV/V + 150 µV 42 µV/V + 50 µV
67 µV/V + 100 µV 83 µV/V + 200 µV
254 µV/V + 600 µV 1.0 mV/V + 2 mV
1.5 mV/V + 3.2 mV
Multifunction calibrator Fluke 5730A
Direct Measurement
Version 006
Issued: February 27, 2020 www.anab.org
Page 17 of 29
Electrical – DC/Low Frequency
Parameter/Equipment Range Expanded Uncertainty of Measurement (+/-)
Reference Standard, Method, and/or
Equipment
AC volt meter AC volt source
(22 to 120) V (10 to 20) Hz (20 to 40) Hz
40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz
(100 to 300) kHz (300 to 500) kHz
500 kHz to 1 MHz (120 to 220) V
(10 to 20) Hz (20 to 40) Hz
40 Hz to 20 kHz (20 to 50) kHz
(50 to 100) kHz (220 to 250) V
(15 to 50) Hz
240 µV/V + 4 mV 90 µV/V + 1.5 mV 52 µV/V + 0.6 mV 80 µV/V + 1 mV
150 µV/V + 2.5 mV 900 µV/V + 16mV 4.4 mV/V + 40 mV 8 mV/V to 80 mV
240 µV/V + 4 mV 90 µV/V + 1.5 mV 52 µV/V + 0.6 mV 80 µV/V + 1 mV
150 µV/V + 2.5 mV
300 µV/V + 16 mV
Multifunction calibrator Fluke 5730A
Direct Measurement
AC voltmeter AC volt source
(220 to 700) V (30 to 50) kHz
(50 to 100) kHz
(220 to 1000) V (40 to 50) Hz
50 Hz to 1 kHz (1 to 20) kHz
(20 to 30) kHz
600 µV/V + 11 mV 2.3 mV/V + 45 mV
90 µV/V + 4 mV 70 µV/V + 3.5 mV 165 µV/V + 6 mV
600 µV/V + 11 mV
Multifunction calibrator Fluke 5730A, 5725A Direct Measurement
AC current meter AC current source
(9 to 220) µA (10 to 20) Hz (20 to 40) Hz
40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz
(0.22 to 2.2) mA (10 to 20) Hz (20 to 40) Hz
40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz
250 µA/A + 16 nA 160 µA/A + 10 nA 120 µA/A + 8 nA
280 µA/A + 12 nA 1.1 mA/A + 65 nA
250 µA/A + 40 nA 160 µA/A + 35 nA 120 µA/A + 35 nA
200 µA/A + 110 nA 1.1 mA/A + 650 µA
Multifunction calibrator Fluke 5730A
Direct Measurement
Version 006
Issued: February 27, 2020 www.anab.org
Page 18 of 29
Electrical – DC/Low Frequency
Parameter/Equipment Range Expanded Uncertainty of Measurement (+/-)
Reference Standard, Method, and/or
Equipment
AC current meter AC current source
(2.2 to 22) mA (10 to 20) Hz (20 to 40) Hz
40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz
(22 to 220) mA (10 to 20) Hz (20 to 40) Hz
40 Hz to 1 kHz (1 to 5) kHz
(5 to 10) kHz (0.22to 2.2) A
20 Hz to 1 kHz (1 to 5) kHz
(5 to 10) kHz
250 µA/A + 400 nA 160 µA/A + 350 nA 120 µA/A + 350 nA 200 µA/A + 550 nA
1.1 mA + 5 µA
250 µA/A + 4 µA 160 µA/A + 3.5 µA 103 µA/A + 2.5 µA 200 µA/A + 3.5 µA 1.1 mA/A + 10 µA
244 µA/A + 35 µA 450 µA/A + 80 µA 7 mA/A + 160 µA
Multifunction calibrator Fluke 5730A
Direct Measurement
AC current meter AC current source
(2.2 to 5.0) A 40 Hz to 1 kHz
(1 to 5) kHz (5 to 10) kHz
(5.0 to 10) A 40 Hz to 1 kHz
(1 to 5) kHz (5 to 10) kHz
460 µA/A + 170 µA 950 µA/A + 380 µA 3.6 mA/A + 750 µA
460 µA/A + 260 µA 950 µA/A + 420 µA 3.6 mA/A + 750 µA
Multifunction calibrator Fluke 5730A, 5725A
Ohm Meter Resistance Source (Specific Value)
1 Ω 1.9 Ω 10 Ω 19 Ω
100 Ω 190 Ω 1 kΩ
1.9 kΩ 10 kΩ 19 kΩ 100 kΩ 190 kΩ 1 MΩ
1.9 MΩ 10MΩ 19 MΩ 100 MΩ
0.1 mΩ 0.18 mΩ 0.23 mΩ 0.44 mΩ
1 mΩ 1.9 mΩ 6.5 mΩ 12 mΩ 65 mΩ 0.12 Ω 0.86 Ω 1.63 Ω 13 Ω
34.2 Ω 0.4 kΩ
0.89 kΩ 10 kΩ
Multifunction calibrator Fluke 5730A
Direct Measurement
Version 006
Issued: February 27, 2020 www.anab.org
Page 19 of 29
Electrical – DC/Low Frequency
Parameter/Equipment Range Expanded Uncertainty of Measurement (+/-)
Reference Standard, Method, and/or
Equipment
DC Dissipated Power
(1 to 11.5) µA Shunt 100 kΩ
(0.1 to 1.15) µA Shunt 1 MΩ
(10 to 115) nA Shunt 10 MΩ
(1 to 11.5) nA Shunt 10 MΩ
(1 to 11.5) nA Shunt 100 MΩ
(0.1 to 1.15) nA Shunt 1 GΩ
(10 to 115) pA Shunt 1 GΩ
(1 to 115) pA Shunt 10 GΩ
(0.1 to 1.15) pA Shunt 100 GΩ
0.013 mA/A + 0.028 nA
0.02 mA/A + 1.7 pA
0.051 mA/A + 0.54 pA
0.026 mA/A + 0.25 pA
0.14 mA/A + 0.11 pA
0.24 mA/A + 0.021 pA
0.24 µA/A + 1.4 fA
0.92 mA/A + 0.38 fA
0.83 mA/A + 0.59 fA
Keysight 16353A, 16353H Shunt, Keysight 3458A
Multimeter
DC Dissipated Power (1 to 3) A (3 to 20) A
0.017 mA/A + 0.12 mA 0.22 mA/A + 0.29 mA
Keysight 16353J Shunt + Keysight 3458A
Multimeter
DC Voltage Measure
(0 to 100) mV (0.1 to 1) V (1 to 10) V
(10 to 100) V (100 to 1 000) V
6.5 µV/V+ 0.42 µV 6 µV/V + 0.42 µV
5.4 µV/V + 0.93 µV 7.6 µV/V + 42 µV 7.6 µV/V + 150 µV
Keysight 3458A Multimeter
DC Current Measure
(0 to 100) µA (0.1 to 1.0) mA (1 to 10) mA
(10 to 100) mA (0.1 to 1) A
24 µA/A + 1.1 nA 24 µA/A + 7.5 nA
24 µA/A + 0.075 µA 41 µA/A + 0.75 µA 120 µA/A + 14µA
Keysight 3458A Multimeter
AC Voltage Meters
1.0 to 10) mV (10 to 40) Hz
40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz
(50 to 100) kHz (100 to 300) kHz
0.035 % of reading + 3.5 µV 0.023 % of reading + 1.3 µV 0.035 % of reading + 1.3 µV 0.12 % of reading + 1.3 µV 0.58 % of reading +1.3 µV 4.6 % of reading + 2.3 µV
Generate using Fluke 5520A Multifunction Calibrator with Multimeter 3458A Direct and Indirect
Measurement
Version 006
Issued: February 27, 2020 www.anab.org
Page 20 of 29
Electrical – DC/Low Frequency
Parameter/Equipment Range Expanded Uncertainty of Measurement (+/-)
Reference Standard, Method, and/or
Equipment
AC Voltage Meters
(10 to 100) mV (10 to 40) Hz
40 Hz to 1 kHz (1 to 20) kHz
(20 to 50) kHz (50 to 100) kHz
(100 to 300) kHz 300 kHz to 1 MHz
100 mV to 1 V (10 to 40) Hz
40 Hz to 1 kHz (1 to 20) kHz
(20 to 50) kHz (50 to 100) kHz
(100 to 300) kHz 300 kHz to 1 MHz
(1 to 10) V (10 to 40) Hz
40 Hz to 1 kHz (1 to 20) kHz
(20 to 50) kHz (50 to 100) kHz
(100 to 300) kHz 300 kHz to 1 MHz
(10 to 100) V (10 to 40) Hz
40 Hz to 1 kHz (1 to 20) kHz
(20 to 50) kHz (50 to 100) kHz
(100 to 200) kHz (10 to 20) V
200 kHz to 1MHz (100 to 700) V
40 Hz to 1 kHz 1 kHz to 20 kHz 20 kHz to 50 kHz 50 kHz to 100 kHz
0.008 4 % of reading + 4.7 µV 0.008 4 % of reading + 2.3 µV 0.017 % of reading + 2.3 µV 0.035 % of reading + 2.3 µV 0.093 % of reading + 2.3 µV 0.35 % of reading + 12 µV 1.2 % of reading + 12 µV
0.008 4 % of reading + 46 µV 0.008 4 % of reading + 23 µV 0.017 % of reading + 23 µV 0.035 % of reading + 23 µV 0.093 % of reading + 23 µV 0.35 % of reading + 0.12 mV 1.2 % of reading + 0.12 mV
0.008 4 % of reading + 0.46 mV 0.008 4 % of reading + 0.23 mV 0.017 % of reading + 0.23 mV 0.035 % of reading + 0.23 mV 0.093 % of reading + 0.23 mV
0.35 % of reading + 1.2 mV 1.2 % of reading + 1.2 mV
0.024 % of reading +4.6 mV 0.024 % of reading + 2.3 mV 0.024 % of reading + 2.3 mV 0.041 % of reading + 2.3 mV 0.14 % of reading + 2.3 mV 0.46 % of reading + 12 mV
1.73 % of reading + 11.6 mV
0.047 % of reading + 16.2 mV 0.07 % of reading + 16.2 mV 0.14 % of reading + 16.2 mV 0.35 % of reading + 16.2 mV
Generate using Fluke 5520A Multifunction Calibrator with Multimeter 3458A Direct and Indirect
Measurement
Version 006
Issued: February 27, 2020 www.anab.org
Page 21 of 29
Electrical – DC/Low Frequency
Parameter/Equipment Range Expanded Uncertainty of Measurement (+/-)
Reference Standard, Method, and/or
Equipment
AC Voltage Meters
(1.0 to 10) mV (1 to 4) MHz (4 to 8) MHz
(10 to 100) mV (1 to 2) MHz (2 to 4) MHz (4 to 8) MHz
(8 to 10) MHz (0.1 to 1) V
(1 to 2) MHz (2 to 4) MHz (4 to 8) MHz
(8 to 10) MHz (1 to 10) V
(1 to 2) MHz (2 to 4) MHz (4 to 8) MHz (8 to 10) MHz
8.1 % of reading + 8.1 µV 23 % of reading + 9.3 µV
17.3 % of reading + 11.6 µV
4.6 % of reading + 81 µV 4.6 % of reading + 92 µV
17.3 % of reading + 11.6 µV
1.73 % of reading + 0.12 mV 4.6 % of reading + 0.81 mV 4.6 % of reading + 0.92 mV
1.73 % of reading + 0.12 mV
17.3 % of reading + 1.16 mV 4.6 % of reading + 8.1 mV 4.6 % of reading + 9.2 mV
17.3 % of reading + 1.16 mV
Generate using Fluke 5520A Multifunction Calibrator with Multimeter 3458A Direct and Indirect
Measurement
AC Current Meters
(10 to 100) µA (10 to 20) Hz (20 to 45) Hz
45 Hz to 1 kHz 100 µA to 1 mA
(10 to 20) Hz (20 to 45) Hz
(45 to 100) Hz 100 Hz to 5 kHz
(1 to 10) mA (10 to 20) Hz (20 to 45) Hz
(45 to 100) Hz 100 Hz to 5 kHz
(10 to 100) mA (10 to 20) Hz (20 to 45) Hz
(45 to 100) Hz 100 Hz to 5 kHz
0.47 % of reading + 0.035 µA 0.18 % of reading + 0.035 µA 0.07 % of reading + 0.035 µA
0.47 % of reading + 0.23 µA 0.18 % of reading + 0.23 µA 0.07 % of reading + 0.23 µA
0.036 % of reading + 0.23 µA
0.47 % of reading + 2.3 µA 0.18 % of reading + 2.3 µA 0.07 % of reading + 2.3 µA 0.036 % of reading + 2.3 µA
0.47 % of reading + 23 µA 0.18 % of reading + 23 µA 0.07 % of reading + 23 µA
0.036 % of reading + 23 µA
Generate using Fluke 5520A Multifunction Calibrator with Multimeter 3458A Direct and Indirect
Measurement
Version 006
Issued: February 27, 2020 www.anab.org
Page 22 of 29
Electrical – DC/Low Frequency
Parameter/Equipment Range Expanded Uncertainty of Measurement (+/-)
Reference Standard, Method, and/or
Equipment
AC Current Meters
100 mA to 1 A (10 to 20) Hz (20 to 45) Hz
(45 to 100) Hz 100 Hz to 5 kHz
0.47 % of reading + 23 mA 0.19 % of reading + 23 mA 0.093 % of reading + 23 mA 0.12 % of reading + 23 mA
Generate using Fluke 5520A Multifunction Calibrator with Multimeter 3458A Direct and Indirect
Measurement
Resistance Measure
(1 to 10) Ω (10 to 100) Ω (0.1 to 1) kΩ
(1 to 10) kΩ
(10 to 100) kΩ (0.1 to 1) MΩ
(1 to 10) MΩ
(10 to 100) MΩ (0.1 to 1) GΩ
21 µΩ/Ω + 8 µΩ/Ω 15 µΩ/Ω + 8 µΩ/Ω
13 µΩ/Ω + 0.79 µΩ/Ω
13 µΩ/Ω + 0.79 µΩ/Ω 13 µΩ/Ω + 0.79 µΩ/Ω 18 µΩ/Ω + 2.6 µΩ/Ω
62 µΩ/Ω + 12 µΩ/Ω
580 µΩ/Ω + 37 µΩ/Ω 5.8 mΩ/Ω + 260 µΩ/Ω
Keysight 3458A
Resistance Meters
(0 to 11) Ω (11 to 33) Ω (33 to 110) Ω
(0.11 to 1.1) kΩ (1.1 to 11) kΩ (11 to 110) kΩ
(0.11to 1.1) MΩ (1.1 to 3.3) MΩ (3.3 to 11) MΩ (11 to 33) MΩ (33 to 110) MΩ (110 to 330) MΩ (0.33 to 1) GΩ
31.2 µΩ/Ω + 0.78 mΩ 23.6 µΩ/Ω + 1.16 mΩ 21.8 µΩ/Ω + 1.17 mΩ 21.7 µΩ/Ω + 1.55 mΩ 21.7 µΩ/Ω + 15.6 mΩ 21.7 µΩ/Ω + 0.16 Ω 24.8 µΩ/Ω + 1.55 Ω 46.6 µΩ/Ω + 23.3 Ω 0.1 mΩ/Ω + 38.8 Ω
0.19 mΩ/Ω + 1.94 kΩ 0.38 mΩ/Ω + 2.32 kΩ 2.33 mΩ/Ω + 77.6 kΩ 11.6 mΩ/Ω + 0.39 MΩ
Multiproduct Calibrator Fluke 5520A,
Direct Measurement
Capacitance - Source
(0.19 to 3.29) nF (3.3 to 10.99) nF (11 to 109.99) nF
(110 to 329.99) nF (0.33 to 1.099) µF (1.1 to 3.299) µF (3.3 to 10.99) µF (11 to 32.99) µF (33 to 109.99) µF (110 to 329.99) µF (0.33 to 1.099) mF
3.2 mF/F + 8.3 pF 1.6 mF/F + 8.3 pF 1.6 mF/F + 83 pF
1.6 mF/F + 0.25 nF 1.6 mF/F + 0.83 nF 1.6 mF/F + 2.5 nF 1.6 mF/F + 8.3 nF 2.5 mF/F + 25 nF 2.8 mF/F + 84 nF
2.8 mF/F + 0.25 µF 4 mF/F + 1.2 µF
Multiproduct Calibrator Fluke 5520A,
Direct Measurement
Version 006
Issued: February 27, 2020 www.anab.org
Page 23 of 29
Electrical – DC/Low Frequency
Parameter/Equipment Range Expanded Uncertainty of Measurement (+/-)
Reference Standard, Method, and/or
Equipment
Capacitance - Source
(1.1 to 3.299) mF (3.3 to 10.99) mF (11 to 32.99) mF (33 to 110) mF
4 mF/F + 3.6 µF 4 mF/F + 12 µF
8.3 mF/F + 36 µF 12 mF/F + 0.11 mF
Multiproduct Calibrator Fluke 5520A,
Direct Measurement
Electrical Simulation of Thermocouple Indicators
Type B (600 to 800) °C
(800 to 1 000) °C (1 000 to 1 550) °C (1 550 to 1 820) °C
Type C (0 to 150) °C
(150 to 650) °C (650 to 1 000) °C
(1 000 to 1 800) °C (1 800 to 2 316) °C
Type E (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C
(650 to 1 000) °C Type J
(-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C
(760 to 1 200) °C Type K
(-200 to -100) °C (-100 to -25) °C (-25 to 120) °C
(120 to 1 000) °C (1 000 to 1 372) °C
Type L (-200 to -100) °C (-100 to 800) °C (800 to 900) °C
0.47 °C 0.36 °C 0.32 °C 0.35 °C
0.32 °C 0.28 °C 0.33 °C 0.53 °C 0.88 °C
0.53 °C 0.18 °C 0.16 °C 0.18 °C 0.23 °C
0.29 °C 0.18 °C 0.16 °C 0.19 °C 0.25 °C
0.35 °C 0.20 °C 0.18 °C 0.28 °C 0.42 °C
0.39 °C 0.28 °C 0.19 °C
Multiproduct Calibrator Fluke 5520A
Version 006
Issued: February 27, 2020 www.anab.org
Page 24 of 29
Electrical – DC/Low Frequency
Parameter/Equipment Range Expanded Uncertainty of Measurement (+/-)
Reference Standard, Method, and/or
Equipment
Electrical Simulation of Thermocouple Indicators
Type N (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 410) °C
(410 to 1 300) °C Type R
(0 to 250) °C (250 to 400) °C
(400 to 1 000) °C (1 000 to 1 767) °C
Type S (0 to 250) °C
(250 to 1 000) °C (1 000 to 1 400) °C (1 400 to 1 767) °C
Type T (-250 to -150) °C
(-150 to 0) °C (0 to 120) °C
(120 to 400) °C Type U
(-200 to 0) °C (0 to 600) °C
0.42 °C 0.24 °C 0.21 °C 0.2 °C 0.29 °C
0.6 °C 0.37 °C 0.35 °C 0.42 °C
0.5 °C 0.38 °C 0.39 °C 0.49 °C
0.66 °C 0.26 °C 0.18 °C 0.16 °C
0.59 °C 0.29 °C
Multiproduct Calibrator Fluke 5520A
4T Capacitance Meter
1 pF (20 to 100) Hz (0.1 to 1) kHz
1 kHz to 1 MHz (1 to 3) MHz (3 to 5) MHz
(5 to 13) MHz 10 pF
(20 to 100) Hz (0.1 to 1) kHz
1 kHz to 1 MHz (1 to 3) MHz (3 to 5) MHz (5 to 13) MHz
15 fF
0.73 fF 3.1E-08 fF/ Hz + 0.09 fF 1.6E-07 fF/ Hz - 0.05 fF 2.3E-07 fF/ Hz - 0.27 fF 3.6E-07 fF/ Hz - 0.96 fF
19 fF
0.82 fF 0.63 fF
2.5E-08 fF/ Hz + 0.6 fF 8.5E-08 fF/ Hz + 0.44 fF 1.3E-07 fF/ Hz + 0.28 fF
Measure using 16380A /16380C Capacitor Set Measure using 16380A /16380C Capacitor Set
Version 006
Issued: February 27, 2020 www.anab.org
Page 25 of 29
Electrical – DC/Low Frequency
Parameter/Equipment Range Expanded Uncertainty of Measurement (+/-)
Reference Standard, Method, and/or
Equipment
4T Capacitance Meter
100 pF (20 to 100) Hz (0.1 to 1) kHz
1 kHz to 1 MHz (1 to 3) MHz (3 to 5) MHz
(5 to 13) MHz 1000 pF
(20 to 100) Hz (0.1 to 1) kHz
1 kHz to 1 MHz (1 to 3) MHz (3 to 5) MHz
(5 to 13) MHz 10 nF
(20 to 100k) Hz 100 nF
(20 to 100k) Hz 1 µF
(20 to 120) Hz 1 kHz 10 kHz
100 kHz 10 µF
(20 to 120) Hz 1 kHz 10 kHz
100 kHz
18 fF 5.2 fF
2.1E-07 fF/ Hz + 5.2 fF 1.2E-06 fF/ Hz + 4.1 fF 3.2E-06 fF/ Hz - 2.1 fF 4.7E-06 fF/ Hz - 10 fF
0.16 pF 0.11 pF
1.1E-05 fF/ Hz + 0.11 pF 9.5E-05 fF/ Hz + 0.02 pF 1.7E-04 fF/ Hz - 0.21 pF 2.9E-04 fF/ Hz - 0.84 pF
0.52 pF
4.4 pF
55 pF 47 pF 48 pF 82 pF
0.78 nF 0.77 nF 1.8 nF 7.7 nF
Measure using 16380A /16380C Capacitor Set Measure using 16380A /16380C Capacitor Set
4T Dissipation Factor2
1 pF (20 to 100) Hz
100 Hz to 1 kHz 1 kHz to 1 MHz
(1 to 4) MHz (4 to 13) MHz
10 pF (20 to 100) Hz
100 Hz to 1 kHz 1 kHz to 1 MHz
(1 to 4) MHz (4 to 13) MHz
9.4E-03 pF 9.20E-04 pF 2.1E-05 pF 3.1E-05 pF 1.6E-04 pF
1.3E-03 pF 8.7E-05 pF 2E-05 pF 2E-05 pF
4.7E-05 pF
Measure using 16380A /16380C Capacitor Set Measure using 16380A /16380C Capacitor Set
Version 006
Issued: February 27, 2020 www.anab.org
Page 26 of 29
Electrical – DC/Low Frequency
Parameter/Equipment Range Expanded Uncertainty of Measurement (+/-)
Reference Standard, Method, and/or
Equipment
4T Dissipation Factor2
100 pF (20 to 100) Hz
100 Hz to 1 kHz 1 kHz to 1 MHz
(1 to 4) MHz (4 to 13) MHz
1 000 pF (20 to 100) Hz
100 Hz to 1 kHz 1 kHz to 1 MHz
(1 to 4) MHz (4 to 13) MHz
10 nF (20 to 120) Hz
1 kHz 10 kHz
100 kHz 100 nF
(20 to 120) Hz 1 kHz 10 kHz
100 kHz 1 µF
(20 to 120) Hz 1 kHz 10 kHz
100 kHz 10 µF
(20 to 120) Hz 1 kHz 10 kHz 100 kHz
1.6E-04 2.1E-05 2E-05 2E-05
5.5E-05
1.9E-04 2E-05 2E-05 3E-05
1.6E-04
2.2E-05 2E-05
2.2E-05 2.2E-05
3.4E-05 2E-05
2.6E-05 3E-05
4.3E-05 2E-05
3.9E-05 4.6E-05
4.3E-05 3E-05
2.8E-04 7.2E-04
Measure using 16380A /16380C Capacitor Set Measure using 16380A /16380C Capacitor Set
Version 006
Issued: February 27, 2020 www.anab.org
Page 27 of 29
Electrical – DC/Low Frequency
Parameter/Equipment Range Expanded Uncertainty of Measurement (+/-)
Reference Standard, Method, and/or
Equipment
4T AC Resistance Meter
0.01 Ω DC
1kHz 0.1 Ω
DC 1kHz
1 Ω DC
1kHz 10 Ω
DC (20 to 100) Hz
100 Hz to 1 MHz (1 to 3) MHz (3 to 5) MHz
(5 to 13) MHz 100 Ω
DC (20 to 100) Hz
100 Hz to 1 MHz (1 to 3) MHz (3 to 5) MHz
(5 to 13) MHz 1 kΩ
DC (20 to 100) Hz
100 Hz to 100 kHz 100 kHz
100 kHz to 1 MHz (1 to 3) MHz (3 to 5) MHz
(5 to 13) MHz 10 kΩ
DC (20 to 100) Hz
100 kHz 100 kHz to 1 MHz
1 MHz
9.9E-04 Ω
1.9E-03 mΩ
2.0E-03 Ω 1.9E-02 mΩ
1.1E-03 Ω 2E-04 Ω
4.1E-03 Ω 6.3E-04 Ω 1.2E-03 Ω
1.4E-09 Ω/ Hz + 2.07E-03 Ω 2.0E-09 Ω/ Hz - 6.7E-05 Ω 6.3E-09 Ω /Hz - 2.2E-2 Ω
1.7E-02 Ω 6E-03 Ω
5.9E-03 Ω 1.0E-08 Ω/ Hz + 2.1E-02 Ω
5.1E-02 Ω 3.2E-08 Ω/ Hz - 1.1E-01 Ω
1.3E-01 Ω 6.1E-02 Ω 5.9E-02 Ω 3.1E-01 Ω 3.1E-01 Ω 3.1E-01 Ω
1.0E-07 Ω/ Hz - 1.7E-03 Ω 3.2E-07 Ω/ Hz - 1.1 Ω
5.2 Ω 2.3 Ω 2.1 Ω 3.2 Ω 3.1 Ω
Measure using 42030A Resistor Set
Version 006
Issued: February 27, 2020 www.anab.org
Page 28 of 29
Electrical – DC/Low Frequency
Parameter/Equipment Range Expanded Uncertainty of Measurement (+/-)
Reference Standard, Method, and/or
Equipment
4T AC Resistance Meter
100 kΩ DC
(20 to 100) Hz 100 kHz
100 kHz to 1 MHz 1 MHz
6.3 Ω 22 Ω 12 Ω 24 Ω 6.6 Ω
Measure using 42030A Resistor Set
DC Power (Power Meters)
3 µW 10 µW 30 µW 100 µW 300 µW 1 mW 3 mW 10 mW 30 mW 100 mW
34 nW 27 nW 42 nW 31 nW
0.23 µW 0.41 µW 1.7 µW 2.8 µW 24 µW
110 µW
Fluke 57X0A Calibrator, Keysight 3458A, HP
11683A
Time and Frequency
Parameter/Equipment Range Expanded Uncertainty of Measurement (+/-)
Reference Standard, Method, and/or
Equipment
Frequency Sources 10 MHz 5 pHz/Hz
Measure using 5071A Frequency
Standard, 53132A Counter Differential measurement
Signal Sources – Frequency 100 MHz to 45 GHz 0.7 Hz
Signal Analyzer E4448A Frequency Standard 5071A
Frequency Standard Differential measurement
Frequency (Source)
(0.1 to 1) Hz 1 Hz to 250 kHz (0.25 to 1) MHz
1 MHz to 40 GHz
2 µHz/Hz + 0.43 µHz 2.4 µHz/Hz
5.2 nHz/Hz + 0.14 mHz 5.3 nHz/Hz
Function Generators 33250A, Signal Generator
E8257D
Frequency (Measure)
(0.1 to 1) Hz (1 to 10) Hz
(10 to 100) Hz 100 Hz to 12.4 GHz
(12.4 to 40) GHz
67 pHz 0.88 nHz 4.7 nHz
24 pHz/Hz 23 pHz/Hz + 1.2 Hz
53132A opt 124 Counter and CW Microwave
Counter 5352B
Version 006
Issued: February 27, 2020 www.anab.org
Page 29 of 29
Time and Frequency
Parameter/Equipment Range Expanded Uncertainty of Measurement (+/-)
Reference Standard, Method, and/or
Equipment
Signal Analyzers, Frequency Counters – Frequency 100 MHz to 50 GHz 1.4 × 10-11 Hz/Hz
Signal Source E8257D, Frequency Standard 5071A Differential measurement
Calibration and Measurement Capability (CMC) is expressed in terms of the measurement parameter, measurement range, expanded uncertainty of measurement and reference standard, method, and/or equipment. The expanded uncertainty of measurement is expressed as the standard uncertainty of the measurement multiplied by a coverage factor of 2 (k=2), corresponding to a confidence level of approximately 95%. Notes: 1. On-site calibration service is available for this parameter, since on-site conditions are typically more variable than those in the laboratory, larger measurement
uncertainties are expected on-site than what is reported on the accredited scope. 2. Unitless linear measure. 3. This scope is formatted as part of a single document including Certificate of Accreditation No. AC-1928.01.