CEPH Op(miza(on on All Flash Storage Axel Rosenberg Systems Field Engineering & Solu(ons Marke(ng
2
Agenda / Talking Points
Ø Challenges of Storage @Scale
Ø CEPH vs IFOS (some Benchmarks)
Ø HDD vs FLASH Ø Object EC vs 3-‐way Replica (some Benchmarks)
Ø FLASH Economics with SDS beyond CEPH / Customer References
& Studies
3
Why was CEPH invented?
4
This is Sage in 2006. He’s an HPC engineer.
5
His Lustre file system isn’t scaling very well and he wants to know why.
6
Eventually he realizes... It’s the metadata!
7
So Sage sits down to write his own file system... one that manages metadata beXer! He calls it Ceph.
8
Ceph is short for cephalopod, like an octopus, because it can do a lot of things in parallel.
9
He likes it so much that he decides to work on it full ]me. He starts a company called Inktank.
10
Everyone loves Inktank. They win lots of awards.
11
Inktank is eventually purchased by Redhat.
12
Tradi]onal file systems use lookup tables to store file loca]ons.
Inode Table Your Files
13
For local file systems, this is easy to manage.
Inode Table
14
For distributed file systems, it’s more difficult.
Inode Table
15
At the Petabyte Scale, it starts to break down.
Inode Table
16
This is why Sage doesn’t like Lustre.
17
CEPH Optimization on All Flash Storage
17
8 Years Later
18
FLASH READINESS? • Started with CEPH Emperor (~2 years ago) • Not much scaling with increasing number of clients • Minimal scaling if we increase number of SSDs • No resources are saturated • CPU core usage per IOPs is very high • Double write due to CEPH journal is increasing WA by minimum 2X
18
19
SanDisk on CEPH • We saw lot of poten]al on CEPH
• Decided to dig deep and op]mize the code base for flash
• CEPH read path was compara]vely easier to tackle, so, started with that first
• Also, lot of our poten]al customer workload was kind of fewer writes and many reads
19
20
IFOS -‐ Enhancing CEPH for Enterprise Consump(on
Open Source Ceph + SanDisk Performance
patches
v Out-‐of-‐the Box configura]ons tuned for performance with Flash
v Sizing & Planning Tool
v Higher node resiliency with Mul]-‐Path support
v Persistent reserva]ons of drives to nodes
v CEPH Installer that is specifically built for InfiniFlash v High Performance iSCSI Storage with SCST deployment per default
v BeXer Diagnos]cs with Log Collec]on Tool v Enterprise hardened QA @scale v InfiniFlash Drive Management integrated into CEPH Management (Coming Soon)
SanDisk CEPH Distro adds Usability & Performance u]li]es without sacrificing Open Source Principles
IFOS = SanDisk Ceph Distribu]on + U]li]es
All CEPH Performance improvements developed by SanDisk are contributed back to community
21
IFOS:…what’s the deal?
22
Innova(ng Performance @Massive Scale InfiniFlash OS Ceph Transformed for Flash Performance and Contributed Back to Community
– 10x Improvement for Block Reads, 2x Improvement for Object Reads
Major Improvements to Enhance Parallelism – Removed single Dispatch queue boXlenecks for
OSD and Client (librados) layers – Shard thread pool implementa]on – Major lock reordering – Improved lock granularity – Reader / Writer locks – Granular locks at Object level – Op]mized OpTracking path in OSD elimina]ng
redundant locks
Messenger Performance Enhancements • Message signing • Socket Read aheads • Resolved severe lock conten]ons
Backend Op(miza(ons – XFS and Flash • Reduced ~2 CPU core usage with improved
file path resolu]on from object ID • CPU and Lock op]mized fast path for reads • Disabled throXling for Flash • Index Manager caching and Shared
FdCache in filestore
23
BOTTLENECKS IDENTIFIED AND FIXED
23
• Op]mized lot of CPU intensive code path • Found out context switching overhead is significant if backend is very fast • Lot of lock conten]on overhead popped up, sharding helped a lot • Fine grained locking helped to achieve more parallelism • New/delete overhead on IO path is becoming significant • Efficient caching of indexes (placement groups) is beneficial • Efficient buffering while reading from socket • Need to disable Nagle’s algorithm while scaling out • Needed to op]mize tcmalloc for object size < 32k
24
So[ware : Ceph Cluster Configura(on auth_cluster_required = none auth_service_required = none auth_client_required = none filestore_xaXr_use_omap = true debug_lockdep = 0/0 debug_context = 0/0 debug_crush = 0/0 debug_buffer = 0/0 debug_]mer = 0/0 debug_filer = 0/0 debug_objecter = 0/0 debug_rados = 0/0 debug_rbd = 0/0 debug_journaler = 0/0 debug_objectcatcher = 0/0 debug_client = 0/0 debug_osd = 0/0 debug_optracker = 0/0 debug_objclass = 0/0 debug_filestore = 0/0 debug_journal = 0/0 debug_ms = 0/0 debug_monc = 0/0
debug_monc = 0/0 debug_tp = 0/0 debug_auth = 0/0 debug_finisher = 0/0 debug_heartbeatmap = 0/0 debug_perfcounter = 0/0 debug_asok = 0/0 debug_throXle = 0/0 debug_mon = 0/0 debug_paxos = 0/0 debug_rgw = 0/0 osd_op_threads = 2 osd_op_num_threads_per_shard = 2 osd_op_num_shards = 7 filestore_op_threads = 3 ms_nocrc = true filestore_fd_cache_size = 64 filestore_fd_cache_shards = 32 cephx_sign_messages = false cephx_require_signatures = false ms_dispatch_throXle_bytes = 0 throXler_perf_counter = false ms_tcp_nodelay = true osd_pool_default_size = 3 osd_pool_default_min_size = 2
[osd] osd_journal_size = 150000 osd_client_message_size_cap = 0 osd_client_message_cap = 0 osd_enable_op_tracker = false osd_mkfs_op]ons_xfs = -‐K [mon] mon_clock_drit_allowed = 1 mon_clock_drit_warn_backoff = 30
Note : For each sotware solu]on there are specific tuning .Refer user guide for details.
25
Time for a Benchmark of..
InfiniFlash(™) System IF500 CEPH with all the op]miza]ons men]oned on top of IF100
+
Proper filesystem/kernel tuning op]mized for IF100 box
25
26
Tools and IO Profiles
Tools used for benchmarking – vdbench ( .503 )
– fio-‐2.1.11 – COSBench 0.4.1.0
IO profiles ( block ) – Small block ( 4K , 8K Random ) – Medium Size ( 64K Random ) – High block ( 256K Random )
IO profiles ( Object ) – Object size (4MB )
27
IF500 topology on a single 512 TB IF100
27
-‐ IF-‐100 BW is ~8.5GB/s (with 6Gb SAS, 12 Gb is coming EOY) and ~1.5M 4K RR IOPS -‐ We saw that Ceph is very resource hungry, so, need at least 2 physical nodes on top of IF-‐100 -‐ We need to connect all 8 ports of an HBA to saturate IF-‐100 for bigger block size
28
Setup details
28
Performance Config -‐ IF500 2 Node Cluster ( 32 drives shared to each OSD node)
Node 2 Servers (Dell R620) 2x E5-‐2680 12C 2.8GHz 4x 16GB RDIMM, dual rank x4 (64GB)
1x Mellanox X3 Dual 40GbE 1x LSI 9207 HBA card
RBD Client 4 Servers (Dell R620) 1 x E5-‐2680 10C 2.8GHz 2 x 16GB RDIMM, dual rank x4 (32 GB) 1x Mellanox X3
Dual 40GbE Storage – IF-‐100 with 64 Icechips in A2 Config IF-‐100 IF-‐100 is connected 64 x 1YX2 Icechips in A2 topology. Total storage -‐ 64 * 8 tb = 512tb
Network Details 40G Switch NA OS Details
OS Ubuntu 14.04 LTS 64bit 3.13.0-‐32 LSI card/ driver SAS2308(9207) mpt2sas
Mellanox 40gbps nw card MT27500 [ConnectX-‐3] mlx4_en -‐ 2.2-‐1 (Feb 2014) Cluster Configura(on CEPH Version sndk-‐ifos-‐1.0.0.04 0.86.rc.eap2
Replica]on (Default) 2 [Host]
Note: -‐ Host level replica]on.
Number of Pools, PGs & RBDs pool = 4 ;PG = 2048 per pool 2 RBDs from each pool
RBD size 2TB Number of Monitors 1 Number of OSD Nodes 2 Number of OSDs per Node 32 total OSDs = 32 * 2 = 64
29
8K Random IO
29
0
50000
100000
150000
200000
250000
300000
1 4 16 1 4 16 1 4 16 1 4 16 1 4 16
0 25 50 75 100
Stock Ceph
Storm 1.0
ceph
ReadPct Threads/worker
Sum of TotalOps
Block Size
IF500
Stock Ceph
Latency(ms)
[Queue Depth] Read Percent
30
64K Random IO
30
[Queue Depth] Read Percent
020000400006000080000
100000120000140000160000
1 4 16 1 4 16 1 4 16 1 4 16 1 4 16
0 25 50 75 100
Stock Ceph
Storm 1.0
ceph
ReadPct Threads/worker
Sum of TotalOps
Block Size
Latency(ms)
IF500
Stock Ceph
We are saturating ~8.5 GB/s IF-100 BW here
31
IF500 scale out Topology
31
32
IF500 HW set up
32
Performance Config 6 Node Cluster ( 8 drives connected to each OSD node) Node 6 Servers
(Dell R620) 2x E5-‐2680 v2 2.8GHz 25M$ 8 x 16GB RDIMM, dual rank (128 GB) 1x Mellanox X3 Dual 40GbE 1x LSI 9207 HBA card
RBD Client 5 Servers (Dell R620)
1 x E5-‐2680 v2 2.8GHz 25M$ 4 x 16GB RDIMM, dual rank (64 GB) 1x Mellanox X3 Dual 40GbE
Network Details 40G Switch NA OS Details
OS Ubuntu 14.04 LTS 64bit 3.13.0-‐32
LSI card/ driver SAS2308(9207) / mpt2sas 16.100.00.00
Mellanox 40gbps nw card MT27500 [ConnectX-‐3] / MLX4_EN mlx4_en -‐ 2.2-‐1 Cluster Configura(on CEPH Version sndk-‐ifos-‐1.0.0.07 0.87-IFOS-1.0.0.7.beta
Replica]on (Default) 3 (CHASSIS)
Note: -‐ chassis level replica]on
Number of Pools, PGs & RBDs pool = 5 ;PG = 2048 per pool 2 RBDs from each pool
RBD size 3TB total DATA SET size = 30TB Number of Monitors 1 Number of OSD Nodes 6 Number of OSDs per Node 8 total OSDs = 6 * 8 = 48
33
4K Random IOPs Performance
33
[Queue Depth] Read Percent
Latency(ms)
With tuning ,maximum cumula]ve performance of ~700K IOPs measured towards 4KB blocks, satura]ng node CPUs at this point.
34
64K Random IOPs Performance
34
[Queue Depth] Read Percent
Latency(ms)
Maximum Bandwidth of 12.8GB/s measured towards 64KB blocks
35
90-10 Random Read Performance
35
[Queue Depth] block size
36
Performance trends
36
60597,88 84505,54
121754,19
183827,8
79288,91 105736,83
174073,72
218235,51
37179,3 48681,03
59981,97 67797,82 55431,02
67530,84 85210,88 92720,89
0
50000
100000
150000
200000
250000
1 2 3 4
4K-100%RR-16QD 4K-100%RR-64QD 16K-90%RR-16QD 16K-90%RR-64QD
Number of Compute Nodes VM configura(on • On single Compute node hosted 4 VMs and each VM is mapped four 1TB RBDs. • VMs root disks also from the same CEPH cluster. • Each VM has 8 virtual CPU and 16GB RAM
37
FLASH Econimics / IF100 HW Intro
38
On Flash Economics, what do you say to the Myth of Flash is expensive?
39
Our All Flash designs delivers breakthrough Features and breakthrough Cost for An All Flash Array
Low Power High Performance Scalable Reliable
Now
Breakthrough Economics
40
InfiniFlash System • Ultra-dense All-Flash Appliance - 512TB in 3U - Best in class $/IOPS/TB
• Scale-out software for massive capacity - Unified Content: Block, Object - Flash optimized software with
programmable interfaces (SDK) • Enterprise-Class storage features - snapshots, replication, thin
provisioning IF500
InfiniFlash OS (Ceph)
Ideal for large-‐scale object storage use cases
41
Scalable Performance 1M IOPS, Latency 1-‐3ms 6– 8GB/s Throughput Upgrade -‐12-‐15GB/s, Nov 15
8TB Flash-‐Card Innova(ons • Enterprise class power-‐fail protec]on • Alerts & monitoring • Latching integrated & monitored • Directly samples air temp • Form-‐factor enables lowest cost SSD
InfiniFlash™ HW Planorm – IF100 Capacity 512TB raw All Flash 3U JBOD of Flash (JBOF) Up to 64 x 8TB cards 4TB cards also available in Q116
Opera]onal Efficiency & Resilient Hot Swappable Architecture, Easy FRU Low power – typical workload 400-‐500W 150W(idle) -‐ 750W(max)
MTBF 1.5+ million hours
Hot Swappable ! Fans, SAS Expander Boards, Power Suppliers, Flash cards
Host Connec(vity Connect up to 8 servers through 8 SAS ports
Available Now
Icechip Drive Card
42
Disaggrega(on is the Key to breakthrough Economics !
InfiniFlash™
Old Model § Monolithic
§ Proprietary Storage OS
§ Costly: $$$$$
New Model § Disaggregated
§ Open Sotware Stack
§ Cost effec]ve: $
So[ware Defined Storage
Standard X86 Servers
Advantages of Disaggrega(on
§ Lower TCA and TCO than tradi]onal models
§ Rich choice of ecosystem partners -‐ compute, networking and sotware stacks
Evidence
§ Decline of tradi]onal frame array business
43
InfiniFlash for OpenStack with Dis-‐Aggrega(on
§ Compute & Storage Disaggrega]on enables Op]mal Resource u]liza]on
§ Allows for more CPU usage required for OSDs with small Block workloads
§ Allows for higher bandwidth provisioning as required for large Object workload
§ Independent Scaling of Compute and Storage § Higher Storage capacity needs doesn't’t force you to
add more compute and vice-‐versa
§ Leads to op]mal ROI for PB scale OpenStack deployments HSEB A HSEB B
OSDs
SAS
….
HSEB A HSEB B HSEB A HSEB B
….
Compu
te Farm
LUN LUN
iSCSI Storage
…Obj Obj
Swit ObjectStore
…LUN LUN
Nova with Cinder & Glance
…
LibRBD
QEMU/KVM
RGW
WebServer
KRBD
iSCSI Target
OSDs OSDs OSDs OSDs OSDs
Storage Farm
Confiden]al – EMS Product Management
44
TCO Example (for Hadoop) -‐ Flash Performance with TCO of HDD
InfiniFlash models are comparable to HDD based TCO with all the benefits of Flash. Note that opera]onal/maintenance cost and performance benefits are not accounted for in these models. $0.60/GB used are an avg representa]ve across high to low-‐end product offerings. Price reduc]on roadmap allows for further InfiniFlash cost improvements not shown in this average model.
$-‐
$20.000.000
$40.000.000
$60.000.000
$80.000.000
$100.000.000
$120.000.000
Trad]onal Hadoop
InfiniFlash Primary Flash + HDD Tier
InfiniFlash with S3 +
disaggregated MR
InfiniFlash S3 with
ErasureCoding
3 year TCO comparison
3 year Opex
TCA 0 50
100 150 200 250 300
Trad]onal Hadoop
InfiniFlash Primary Flash +
HDD Tier
InfiniFlash with S3 + disaggregated
MR
InfiniFlash S3 with ErasureCoding
Total Rack
45
Example: 6PB Datalake solu(on on Infiniflash vs HDD array
§ InfiniFlash results in TCA reduc]on & even higher Opex savings
§ Determinis]c QoS with all Flash architecture vs HDD array
§ InfiniFlash with Erasure Coded configura]on of 9:3 ra]o leads to higher storage efficiency (8PB raw, 6PB useable)
§ InfiniFlash technology roadmap leads to ~10% YoY cost reduc]on
§ Further savings (not shown) on opera]onal & maintenance costs related to higher failure rate of HDDs vs. Flash
– Does not require over provisioning of storage to compensate for inconsistent performance due to high failure rates of HDD
§ Service costs are not included in either products
Es]mate used for Isilon: $1.2M/1PB usable capacity
$(1,50)
$0,50
$2,50
$4,50
$6,50
$8,50
$10,50
Isilon InfiniFlash w / EC
Millions
Σ OPEX
Σ TCA
$1.5M savings es]mated for a 6PB deployment
46
CEPH RECOVERY OPTIMIZATION
47
Client IO recovery a[er 1 OSD drive down/out with default sesngs
IOPS :2 Luns /Client ( Total 5 Clients) : Profile : 64K Block Random Read
Recovery ]me in second
0
20000
40000
60000
80000
100000
120000
140000
160000
180000 30
180
330
480
630
780
930
1080
1230
1380
1530
1680
1830
1980
2130
2280
2430
2580
2730
2880
3030
3180
3330
3480
3630
3780
3930
4080
4230
4380
4530
4680
4830
4980
5130
5280
5430
5580
5730
5880
a. Recovery Parameters with default se�ngs b. Recovery/rebalancing ]me is around 90 min when one osd down with IO load of 64k RR_qd64 (user data 30tb ; with 3 way
replica]on total data on cluster is 90tb and each osd consists of around 2TB). c. Average perf degrada]on is around 60% when recovery is happening.
Op]mal perf
IOPS
48
Client IO with recovery after the ‘down’ OSD is ‘in’
48
Note:- a. Recovery/rebalancing ]me is around 60 min when one osd in with IO load of 64k RR_qd64 b. Average perf degrada]on is around 5% when recovery is happening. c. Recovery parameters with priority to client IO
Recovery time in second
49
Client IO recovery a[er 1 OSD drive down/out with tuning IOPS :2 Luns /Client ( Total 5 Clients) Profile : 64K Random Read
Recovery (me in second Note:-‐ a. Recovery Parameters sesng with Priority to Client(applica(on) IO . b. Recovery/rebalancing ]me is around 90 min when one osd down with IO load of 64k RR_qd64 (user data 10tb ; with 3 way replica]on total data on cluster is 30tb and each osd consists of around 1.2TB). c. Average perf degrada]on is around 15% when recovery is happening.
0
50000
100000
150000
200000
250000 0
150
300
450
600
750
900
1050
1200
1350
1500
1650
1800
1950
2100
2250
2400
2550
2700
2850
3000
3150
3300
3450
3600
3750
3900
4050
4200
4350
4500
4650
4800
4950
5100
5250
5400
5550
5700
5850
Recovery
Op]mal
50
Client IO with recovery a[er 1 OSD drive back IN with tuning IOPS :2 Luns /Client ( Total 5 Clients)
Recovery (me in second
Note:-‐ a. Recovery Parameters with priority to Client IO during drive coming back to cluster b. Recovery/rebalancing ]me is around 60 min when one osd in with IO load of 64k RR_qd64 c. Average perf degrada]on is around 5% when recovery is happening.
0
50000
100000
150000
200000
250000 0
150
300
450
600
750
900
1050
1200
1350
1500
1650
1800
1950
2100
2250
2400
2550
2700
2850
3000
3150
3300
3450
3600
3750
3900
4050
4200
4350
4500
4650
4800
4950
5100
5250
5400
5550
5700
5850
Recovery
Op]mal
51
Client IO recovery a[er Chassis down/out with default sesngs IOPS :2 Luns /Client ( Total 5 Clients) Profile : 64K Random Read
Recovery ]me in second
Note:-‐ • Recovery parameters with default priority to client IO . • Recovery/rebalancing ]me is around 6 hours when one chassis down with IO load of 64k RR (user data 30tb ) with 3 way
replica]on total data on cluster is 90tb and each chassis consists of around 30 TB).
0 20000 40000 60000 80000 100000 120000 140000 160000 180000 200000
30
570
1110
1650
2190
2730
3270
3810
4350
4890
5430
5970
6510
7050
7590
8130
8670
9210
9750
10290
10830
11370
11910
12450
12990
13530
14070
14610
15150
15690
16230
16770
17310
17850
18390
18930
19470
20010
20550
21090
op]mal_perf
Recovery_Perf
IOPS
52
Recovery_IO_Perf_of_64K_Rand_Read qd64: Chassis down/out IOPS :2 Luns /Client ( Total 5 Clients)
Recovery (me in second Note:-‐ a. Recovery Parameters with priority to Client IO b. Recovery/rebalancing ]me is around 7 hours when one chassis down with IO load of 64k RR
0
50000
100000
150000
200000
250000 0
750
1500
2250
3000
3750
4500
5250
6000
6750
7500
8250
9000
9750
10500
11250
12000
12750
13500
14250
15000
15750
16500
17250
18000
18750
19500
20250
21000
21750
22500
23250
24000
24750
25500
26250
27000
27750
28500
29250
IOPS
Recovery
Op]mal
53
Client IO with recovery a[er Chassis back in with tuning IOPS :2 Luns /Client ( Total 5 Clients)
Recovery (me in second Note:-‐ Recovery/rebalancing ]me is around 2 hours ater adding removed chassis with IO load of 64k RR_qd64 (user data 10tb ; with 3 way replica]on total data on cluster is 30tb and each chassis consists of around 10 TB).
0
50000
100000
150000
200000
250000
0 210
420
630
840
1050
1260
1470
1680
1890
2100
2310
2520
2730
2940
3150
3360
3570
3780
3990
4200
4410
4620
4830
5040
5250
5460
5670
5880
6090
6300
6510
6720
6930
7140
7350
7560
7770
7980
8190
8400
8610
8820
Recovery
Op]mal
54
Object Storage Topology
Note : Clients are not shown in above topology . COSBench is used to generate the workload from Clients
Benchmark Environment – Ceph release : Giant ( .87.1 ) – Object Interface : S3 – WebServer : Civetweb
Workload Generator
– COSBench 0.4.1.0 IO Profiles
– 4MB Object Random Read – 4MB Object Random Write
55
Hardware Configura(on Performance Config -‐ DA IF100 with Quarter Pop
6 Node Cluster ( 8 drives connected to each OSD node)
Node 6 Servers (Dell R720) 2x E5-‐2680 v2 2.8GHz 25M$ 8 x 16GB RDIMM, dual rank (128 GB)
1x Mellanox X3 Dual 40GbE 1x LSI 9207 HBA card
RGW Gateway (Rados gateway Server) 4 Servers (Dell R620)
1 x E5-‐2680 v2 2.8GHz 25M$ 4 x 16GB RDIMM, dual rank (64 GB) 1x Mellanox X3 Dual 40GbE
Storage – IF100 with 16 Drives ( Par((oned 8 Drives to each Storage Node using Reserva(on)
IF100 ( Chassis) Storage Connected to 2 Hosts with Reserva]on(refer fig) Total storage -‐ 16 * 8 Tb = 128TB
IF100-‐ Package Version DA build FFU 1.0.0.31.1
Network Details 40G Switch Brocade VDX 8770 OS Details
OS Ubuntu 14.04 LTS 64bit 3.13.0-‐24
LSI card/ driver SAS2308(9207) / mpt2sas 16.100.00.00
Mellanox 40gbps nw card MT27500 [ConnectX-‐3] / MLX4_EN mlx4_en -‐ 2.2-‐1 Cluster Configura(on CEPH Version sndk-‐ifos-‐1.0.0.07 0.87-‐IFOS-‐1.0.0.8.beta
Replica]on (Default) 3 (CHASSIS)
Note: -‐ chassis level replica]on ( depends on tests)
Number of Pools, PGs & RBDs pool = 5 ;PG = 2048 per pool EC Pool
Number of Monitors 3 recommended to have 3 Monitor for Deployment Number of OSD Nodes 6 Number of OSD drives per OSD Node 8 total OSDs = 6 * 8 = 48
56
So[ware : Ceph Cluster Configura(on § auth_cluster_required = none § auth_service_required = none § auth_client_required = none § filestore_xaXr_use_omap = true § debug_lockdep = 0/0 § debug_context = 0/0 § debug_crush = 0/0 § debug_buffer = 0/0 § debug_]mer = 0/0 § debug_filer = 0/0 § debug_objecter = 0/0 § debug_rados = 0/0 § debug_rbd = 0/0 § debug_journaler = 0/0 § debug_objectcatcher = 0/0 § debug_client = 0/0 § debug_osd = 0/0 § debug_optracker = 0/0 § debug_objclass = 0/0 § debug_filestore = 0/0 § debug_journal = 0/0 § debug_ms = 0/0 § debug_monc = 0/0 § debug_tp = 0/0 § debug_auth = 0/0 § debug_finisher = 0/0 § debug_heartbeatmap = 0/0 § debug_perfcounter = 0/0 § debug_asok = 0/0 § debug_throXle = 0/0 § debug_mon = 0/0 § debug_paxos = 0/0 § debug_rgw = 0/0
osd_op_threads = 2 osd_op_num_threads_per_shard = 2 osd_op_num_shards = 7 filestore_op_threads = 3 ms_nocrc = true filestore_fd_cache_size = 64 filestore_fd_cache_shards = 32 cephx_sign_messages = false cephx_require_signatures = false ms_dispatch_throXle_bytes = 0 throXler_perf_counter = false ms_tcp_nodelay = true osd_pool_default_size = 3 osd_pool_default_min_size = 2 osd_recovery_max_ac]ve = 1 osd_max_backfills = 1 osd_recovery_threads = 1 osd_recovery_op_priority = 1 rbd_cache = false objecter_inflight_ops = 2048000 objecter_inflight_bytes = 10485760000000000 rgw_thread_pool_size = 1024 rgw_cache_enable = true [osd] osd_journal_size = 150000 osd_mkfs_op]ons_xfs = -‐K osd_client_message_size_cap = 0 osd_client_message_cap = 0 osd_enable_op_tracker = false [mon] mon_clock_drit_allowed = 30 mon_clock_drit_warn_backoff = 30
[client.radosgw.gateway-‐1] host = rack1-‐ramp-‐1 keyring = /etc/ceph/ceph.client.admin.keyring rgw_socket_path = /var/log/ceph/radosgw1.sock log_file = /var/log/ceph/radosgw-‐1.rack1-‐ramp-‐1.log rgw_max_chunk_size = 4194304 rgw_frontends = "civetweb port=8081" rgw_dns_name = rack1-‐ramp-‐1 rgw_ops_log_rados = false rgw_enable_ops_log = false rgw_cache_lru_size = 1000000 rgw_enable_usage_log = false rgw_usage_log_]ck_interval = 30 rgw_usage_log_flush_threshold = 1024 rgw_exit_]meout_secs = 600
57
EC Performance on InfiniFlash Erasure Code Pool Configura(on
– Host level Erasure coding 4:2 ( k:m ) – Jerasure and technique is Cauchy-‐good – .rgw.buckets are in Erasure coding pool others in replicated pool
– Object performance scales up with increase number of RGW servers & instances
– Erasure Coding with InfiniFlash is very CPU efficient compared to HDDs
– For all cases of read/write, op]mal/recovery tests the latency is 20%-‐50% beXer with Cauchy Good
profile BW(GB/s) 90% -‐
RespTime (ms)
Avg. CPU usage of OSD nodes(%)
disk usage (%)
Network usage OSD nodes
Avg. CPU usage
of RGW-‐CPU(%)
Network usage RGW
send/recv
Avg. total disk bw of
each OSD node(GB/s)
4M_write(ds:20tb) 4.1 820 40-‐45 80-‐90 1.6GB/s -‐ receive 20-‐25 s/r: 1.1G/1.1G 2.2
4M_read(ds:20tb) 14.43 220 50-‐55 85-‐93 4.2GB/s -‐ send 50-‐52 80-‐85 2.2
Ceph Gateway Servers • No. of RGW Servers: 4 • No. oF RGW Instances: 16 • No. of Clients: 4
58
Write Performance with Scaling OSD
58
Write Object performance with EC pool scaling from 48 Drives to 96 drives
Profile No of OSD Drives
No of RGW servers
No of RGW instances
Clients Workers BW(GB/s) 90% -‐ RespTime(ms)
Avg. CPU usage of OSD nodes(%)
Avg. CPU usage of RGW-‐nodes(%)
Avg. CPU usage of COSBENCH-‐CPU(%)
4M_Write 48 4 16 4 512 2.86 1870 40 10 15
4M_Write
96 4 16 4 512 4.9 420 65-‐70 30-‐35 40-‐45
– With increase in OSD drives( 2x) write performance improve by around 65-‐70%
59
Op(mal EC Performance: Cauchy-‐good
59
Profile No of RGW servers
No of RGW instances
Clients Workers BW(GB/s) 90% -‐ RespTime(ms)
Avg. CPU usage of OSD nodes(%)
Avg. CPU usage of RGW-‐nodes(%)
4M_Write(ds:20 TB)
4 16 4 512 4.1 820 40-‐45 20-‐25
4M_Read (ds:20 TB)
4 16 4 512 14.33 220 50-‐55 50-‐52
• Cauchy good Op]mal write performance is at least 33% beXer Reed Solomon.
in some runs got around 45% improvement • Cauchy good Op]mal read performance 10% beXer however there was no much scope
of improvement as we were already satura]ng the N/W bandwidth of RGW nodes.
60
Degraded EC Read Performance: Reed-‐Solomon vs Cauchy-‐good
60
Cluster Profile BW(GB/s) 90% -‐ RespTime(ms) Avg. CPU usage of OSD nodes(%)
Cauchy_good Degraded (1 Node Down) 4M_Read 12.9 230 71
Cauchy_good
Degraded (2 Node Down) 4M_Read 9.83 350 75-‐80
RS Degraded (1 Node Down)
4M_Read 8.26 250 60
RS
Degraded (2 Node Down)
4M_Read 3.88 740 50-‐55
Cauchy_Good is doing far beXer than Reed Solomon technique for op]mal and recovery IO performance as compared with write performance: ge�ng almost double
61
Replica(on vs Erasure Coded Pool
0
0,5
1
1,5
2
2,5
3
EC-‐Write Rep-‐Write EC-‐Read Rep-‐Read
GB/s
Bandwidth
Single Gateway Node Performance between Replicated and Erasure Coded Pool Erasure Code Pool Configura(on
– OSD level Erasure coding 9:3 ( k:m ) – Jerasure and technique is Reed Solomon – .rgw.buckets to be in Erasure coding pool others to be in replicated pool
Bandwidth(GB/s) 90% Resp Time
EC-‐Write 1.1 170
Rep-‐Write 1.39 130
EC-‐Read 2.5 320
Rep-‐Read 2.58 250
– No major degrada]on in performance for EC pool compared to replicated pool for read and write
62
CPU/Memory/Disk Usage
63
4K Random Read Performance stats for Block IO
QD
0
200000
400000
600000
800000
1 2 4 8 16 32 64 128 256
IOPS
0
1
2
3
4
1 2 4 8 16 32 64 128 256
Latency(ms)
0
50
100
150
1 2 4 8 16 32 64 128 256
%CP
U usage
%CPU usage -‐ osd node
0
200
400
600
1 2 4 8 16 32 64 128 256
netstats-‐osd node(MB/s)
0
50
100
150
1 2 4 8 16 32 64 128 256
% disk usage
% disk usage -‐ osd node
0
20
40
60
80
100
1 2 4 8 16 32 64 128 256
% CPU
usage
% Avg. of clients CPU usage
64
64K Random Read Performance stats for Block IO
QD
0
50000
100000
150000
200000
1 2 4 8 16 32 64 128 256
IOPS
IOPS
0
20
40
60
80
1 2 4 8 16 32 64 128 256
%CP
U usage
%CPU usage -‐ osd node
0
50
100
150
1 2 4 8 16 32 64 128 256
% disk usage
% disk usage -‐ osd node
0
500
1000
1500
2000
2500
1 2 4 8 16 32 64 128 256
KB/s
N/W stats osd node(MB/s)
0
20
40
60
80
100
1 2 4 8 16 32 64 128 256
% CPU
usage
% Avg. of clients CPU usage
0
5
10
15
1 2 4 8 16 32 64 128 256
Latency(ms)
Latency(ms)
65
256K Random Read Performance stats for Block IO
QD
0
2000
4000
6000
8000
10000
12000
1 2 4 8 16 32 64 128 256
MB/sec
0
20
40
60
80
1 2 4 8 16 32 64 128 256
Latency(ms)
0
10
20
30
40
1 2 4 8 16 32 64 128 256
%CP
U usage
%CPU usage -‐ osd node
0
1000
2000
1 2 4 8 16 32 64 128 256
netstats-‐osd node(MB/s)
0 20 40 60 80 100 120
1 2 4 8 16 32 64 128 256
% disk usage
% disk usage -‐ osd node
0
20
40
60
80
100
1 2 4 8 16 32 64 128 256
% CPU
usage
% Avg. of clients CPU usage
66
Response Time varia(on for 64K 100% Random Read
0
10
20
30
40
50
60
70
80
% IO
Latency range in usec
64k_RR on single RBD Range in us 99.99% data
100 0.01 250 0.01 500 0.03 750 0.04 1000 0.23 2000 13.91 4000 67.05 10000 18.64 20000 0.02 50000 0.02 100000 0.01 250000 0.06 500000 0.01 750000 0.01
67
Erasure Coding Summary § Cauchy Good is doing far beXer than Reed Solomon technique for op]mal and recovery IO performance as compared wrt write
performance: ge�ng almost double(with reed_sol :2 .6 and Cauchy Good: 4.1)
§ Cauchy Good op]mal write performance is at least 33% beXer Reed Solomon. In some runs got around 45% improvement
§ Cauchy Good op]mal read performance is 10% beXer as there is satura]on the nw bw of osd nodes , there was no scope of improvement.
§ Cauchy Good recovery read performance is beXer than Reed Solomon by at least 33%. In some runs we are ge�ng around 50% improvement for single OSD node down scenarios.
§ For fully degraded scenarios ( 2 Node down)Cauchy Good recovery read performance is beXer than Reed Solomon by at least 100%. In some runs we are ge�ng around 125% read improvement.
§ For all the cases read/write and op]mal/recovery the latency with Cauchy Good is beXer 20%-‐50% beXer. In some runs it is even 80% beXer.
§ For writes we are able to saturate/u]lize the max disk bandwidth with Cauchy Good and for reads there is no much scope to saturate the disk bandwidth.
§ With increased CPU u]liza]on about 20% in some cases we are improving performance about 33% with Cauchy Good, which points Cauchy Good is the encoding technique to choose.
68
IF500 future goals
• Improved write performance
• Improved write amplifica]on
• Improved mixed read-‐write performance
• Convenient end-‐to-‐end management/monitoring UI
• Easy deployment
• RDMA support
• EC with block interface
68
69
Fully Validated So[ware Defined All Flash Solu(ons for Scale Up and Scale Out Applica(ons
Scale Up Scale Out
Infiniflash
• File : ,
• Block: ION Accelerator,
• File – IBM GPFS, Gluster, Cloudbyte • Object – • Block –
Software
HW
For Databases, VDI, OpenStack, Cloud Backends, File, Print, and more
70
1 GPFS Enterprise License/Rack
GPFS Client Plug-‐in Only
IF100 Advantages • All-‐flash @ lower TCO than HDD-‐arrays • Disaggregated compute
• 18 node license down to 3 • Added Client Plugin
• IF100 performance • 7GB/s (Now) à 14GB/s (Q4’15) • 128TB T1/T2 storage served from a
single box • Best capacity u]liza]on
• Local Protec]on available w. 2 way replica vs. 3-‐way on HDD
• Moving to Erasure Coded w. GNR will further enable capacity u]liza]on improvements
Enterprise Public Cloud SAAS InfiniFlash w. GPFS Scale-‐Out
71
GPFS Integra(on & op(miza(on…. • @ Scale tes]ng by SNDK, hos]ng mul]ple customer
PoC’s • GPFS basic cer]fica]on by IBM – ongoing NOW • preliminary results available by IBM Labs • IBM GNR cer]fica]on & fully integrated solu]on by
SanDisk – target Q415 • Solu]on will be offered by partners as complete
reference architecture with choice of server vendor
12 Month Roadmap Delivers Performance Doubling…. • Expander upgrade to 12G to x2 throughput in Nov 2015
• 32+ Icechip scaling limita]on (6G expander) resolved • 4TB Icechip introduc]on in early Q12016 à right scaling capacity to BW • 12G Icechip upgrade will x2 performance once again maximizing box performance at low capacity
Confiden]al-‐ EMS Product Management
IF100+GPFS Solu(on Ref Architecture @SNDK IBM Labs Cer(fica(on In Progress
72
OpenStack Private Cloud on InfiniFlash – IF500 Telco Customer
§ High Performance OpenStack Private Cloud Infrastructure on InfiniFlash
§ Cinder Storage driven by Ceph on IF500
§ First migrate latency sensi]ve workloads
§ Splunk Log Analy]cs,
§ Ka�a Messaging runs on InfiniFlash
§ 10x performance over HDD based Ceph
§ Co-‐exists with low performance HDD based Ceph
§ Highly scalable with lowest TCO
§ 2-‐copy model -‐ reduced from 3 copy HDD model
§ Ease of deployment w. reduced footprint, power, thermal management
HSEB A HSEB B
SAS HSEB A HSEB B
Compu
te Farm LUN LUN
Splunk
LibRBD
QEMU/KVM
Storage Farm
LUN LUN
Ka�a
LibRBD
QEMU/KVM ….
73
Before With IF500….. § Customer deployed OpenStack based private cloud
on RH Ceph
§ Pain-‐points
• Cinder storage based on Ceph being used on HDD could not get over 10K IOPS (8K blocks)
• Limi]ng private cloud expansion to include higher performance applica]ons
§ Solu(ons considered before IF500 did not work..
• Alternate solu]ons with separate storage architectures for high performance applica]ons add significant costs and higher management overhead defea]ng the purpose of OpenStack
§ Able to meet their higher performance goals with the same IF500-‐ Ceph based architecture without disturbing their exis(ng infrastructure
• Ceph cluster on HDD will co-‐exist with IF500 Ceph cluster. Applica]ons get deployed on either based on performance needs
• Ini]al workloads migrated: u Deploying Splunk log Analy]cs
u Apache Ka�a messaging system u Cassandra (Next target)
§ Adding performance in lower TCO footprint • 2x128TB IF500 à expanding to 256TB in next phase
• Expected to reduce real estate to < 1/3
• >50% power reduc]on expected
OpenStack Private Cloud on InfiniFlash – IF500 Telco Customer
74
SanDisk is introducing Disaggregated So[ware Defined All Flash Solu(ons for target workloads.
Hadoop Object Hyperscale
xSP Unified Storage Mixed Work.
CDN -‐ Edge Caching & Streaming
Enterprise Unified Storage Mixed-‐Work.
Industry Ver]cal Apps Object Based
NoSQL Databases
Web2.0 Indexing OCP
Ac]ve Archive
Hadoop HDFS Tiered
Video Surveillance Enterprise
Hyperscale Custom Block
Apps
Ent. Block Data
Warehouse
HPC & File-‐based
Scale Up
Collabora]ve Decision Support Biz Processing App Dev
Tier 1 , Tier 2 Databases
DataLakes @Scale Obj, File
Scale Out
IT Infra. Web Infra Indust. R&D
Online Media Storage & Streaming
Win App Exchange, SharePoint
Enterprise Unified Storage Mixed-‐Work.
Back-‐ups
SanDisk offers complete disaggregated reference designs for target workloads. Reference designs include CNSSS (Compute, Networking, Storage, Sotware, Support)
75 Flash Memory Summit 2015 Santa Clara, CA
75
Thank you ! Ques(ons? [email protected]
© 2015 SanDisk Corpora]on. All rights reserved. SanDisk is a trademark of SanDisk Corpora]on, registered in the United States and other countries. InfiniFlash and IF500 are trademarks of SanDisk Enterprise IP LLC. Other brand names men]oned herein are for iden]fica]on purposes only and may be the trademarks of their respec]ve holder(s).
76
This is especially important at the petabyte scale.
77
GPFS
Detailed Performance Analysis of Solid State Disks Hussein N. El-‐Harake and Thomas Schoenemeyer Swiss Na]onal Supercompu]ng Centre (CSCS), Manno, Switzerland [email protected], [email protected] Integra(ng FusionIO SSD with GPFS for IOP Performance Madhav Ponamgi Joshua Blumert © 2010, IBM Advanced Technical Skills Techdocs Version 10/25/2010 hXp://w3.ibm.com/support/Techdocs Tips Techdocs Document
78
Efficient and High-‐Performance Cloud Solu(on for IBM Tivoli Storage Manager
951 SanDisk Drive | Milpitas | CA 95035 | USA
At SanDisk, we’re expanding the possibilities of data storage. For more than 25 years, SanDisk’s ideas have helped transform the industry, delivering next generation storage solutions for consumers and businesses around the globe.
“The savings were enormous.
We are now able to fully
utilize the processors in our
TSM servers. This allows us to
cut our server footprint (and
accompanying floor space,
power and cooling costs) by two-
thirds. At the same time, we’ve
increased the speed of database
backups and tasks like inventory
expiration jobs, which makes our
servers more responsive.”
Geirr G. Halvorsen Senior Systems Engineer Front-safe
• Databases on internal disks in a RAID • Moved databases from disks to 320GB Fusion ioMemory card
TSM Servers
TSM Server
320GB Fusion ioMemory card
3:1 Server Consolidation
System Overview
System Before System After
Contact information
SanDisk951 SanDisk Drive Milpitas, CA 95035-7933, USA T: 1-800-578-6007
SanDisk Europe, Middle East, AfricaUnit 100, Airside Business Park Swords, County Dublin, Ireland T: 1-800-578-6007
SanDisk Asia PacificSuite C, D, E, 23/F, No. 918 Middle Huahai Road, Jiu Shi Renaissance Building Shanghai, 20031, P.R. China T: 1-800-578-6007
For more information, please visit: www.sandisk.com/enterprise
“The savings were enormous. We are now able to fully utilize the processors in our TSM servers. This allows us to cut our server footprint (and accompanying floor space, power and cooling costs) by two-thirds,” Geirr said. “At the same time, we’ve increased the speed of database backups and tasks like inventory expiration jobs, which makes our servers more responsive. Our customers have noticed the di!erence.”
Easy Implementation and Rapid Software Upgrade
Implementing the Fusion ioMemory cards proved much easier than upgrading to a SAN.
Geirr told us, “Adding a SAN would have required serious planning and thought toward disk architecture, and the physical upgrade would have taken days. It took 30-45 minutes to physically install the Fusion ioMemory cards and copying the databases was very fast.”
Front-safe also took this opportunity to upgrade from TSM 5.5 to 6.2 and discovered rapid upgrades were another unexpected benefit. “IBM estimates a 50-100GB upgrade will take one to three days on a disk-based system,” Geirr said. “The same upgrade on a SanDisk powered system finished in less than five hours.”
Summary
Implementing the Fusion ioMemory solution gave Front-safe the following benefits:• Query times from minutes to seconds• Tivoli expiration jobs from hours to minutes• 3x higher TSM workload• 3:1 server consolidation from improved workload• Easy implementation• 5x faster TSM software upgrade
About the Customer
Front-safe is a Danish-owned company in the JS Holding Group, which in total counts more than 100 employees. Front-safe is a dedicated and focused supplier of backup and archiving solutions, proactively protecting businesses of all types and sizes from data loss. Front-safe operates in Denmark with redundant data centers and o"ces in Aarhus and Copenhagen. Front-safe provides automated and secure remote online backup, disaster recovery and archiving solutions freeing its customers’ resources so they can focus on their core businesses.
The performance results discussed herein are based on internal Front-safe testing and use of Fusion ioMemory products. Results and performance may vary according to configurations and systems, including drive capacity, system architecture and applications.
©2014 SanDisk Corporation. All rights reserved. SanDisk is a trademark of SanDisk Corporation, registered in the United States and other countries. Fusion ioMemory, and others are trademarks of SanDisk Enterprise IP LLC. Other brand names mentioned herein are for identification purposes only and may be the trademarks of their respective holder(s).
79
TSM (or any other Backup / Restore app)
CASE STUDY
The Challenge
Front-safe is a dedicated and focused supplier of backup and archiving solutions, proactively protecting businesses of all types and sizes from data loss. IBM Denmark’s Cloud Partner of the Year in 2010, Front-safe o!ers a unique online, user-friendly web interface that tightly integrates with IBM’s Tivoli Storage Manager (TSM), creating a cloud solution that makes TSM easily available to large and small businesses. Front-safe automates backup and recovery, while also providing reporting and dynamic invoicing.
As Front-safe’s customer base and data volume grew, delivering the best-in-class service its customers expected began to be challenging.
Geirr G. Halvorsen, Senior Systems Engineer, told us the challenges Front-safe faced: “As the database grew, maintenance tasks on this database were becoming very time consuming, using resources needed for other tasks. Server resources showed low processor utilization, but high I/O demand. Our goal was to reduce the time we spent on database maintenance tasks, improve the utilization of our server resources and, if possible, consolidate IBM Tivoli Storage Manager Servers.”
The SanDisk® Solution
“As we researched solutions, we looked at adding more disks and using them di!erently to maximize I/O—but that would require a SAN, which would increase our data center footprint, increase power and cooling costs, and still wouldn’t give us enough performance. Conventional SSDs didn’t provide us the capacity,” Geirr told us. “We chose the Fusion ioMemory™ solution because it gave us the highest performance with our existing hardware.”
Securing Front-safe Performance
The Fusion ioMemory card dramatically improved the performance of the TSM database. Geirr told us, “Front-safe worked closely with SanDisk sta! to install the Fusion ioMemory card and measure performance. We moved several of our highest workload databases onto the SanDisk products and saw significant performance improvements. For example, inventory expiration jobs were reduced from hours to minutes and operational queries from minutes to seconds. This freed up resources for additional database work.”
A Smarter System for Better Service and Attractive Pricing
Front-safe used the increased workload capabilities to reduce its infrastructure needs and operating costs.
Front-safe Creates an E!cient and High-Performance Cloud Solution for IBM Tivoli Storage Manager Backup and archive solutions provider improves performance and slashes database server footprint to o!er best-in-class service at an attractive price.
Solution Focus• Tivoli Storage Manager (TSM)• Cloud computing
Summary of Benefits• Query times from minutes to seconds• Tivoli expiration jobs from hours
to minutes• 3x higher TSM workload• 3:1 server consolidation from
improved workload• Easy implementation• 5x faster TSM software upgrade
951 SanDisk Drive | Milpitas | CA 95035 | USA
At SanDisk, we’re expanding the possibilities of data storage. For more than 25 years, SanDisk’s ideas have helped transform the industry, delivering next generation storage solutions for consumers and businesses around the globe.
“The savings were enormous.
We are now able to fully
utilize the processors in our
TSM servers. This allows us to
cut our server footprint (and
accompanying floor space,
power and cooling costs) by two-
thirds. At the same time, we’ve
increased the speed of database
backups and tasks like inventory
expiration jobs, which makes our
servers more responsive.”
Geirr G. Halvorsen Senior Systems Engineer Front-safe
• Databases on internal disks in a RAID • Moved databases from disks to 320GB Fusion ioMemory card
TSM Servers
TSM Server
320GB Fusion ioMemory card
3:1 Server Consolidation
System Overview
System Before System After
Contact information
SanDisk951 SanDisk Drive Milpitas, CA 95035-7933, USA T: 1-800-578-6007
SanDisk Europe, Middle East, AfricaUnit 100, Airside Business Park Swords, County Dublin, Ireland T: 1-800-578-6007
SanDisk Asia PacificSuite C, D, E, 23/F, No. 918 Middle Huahai Road, Jiu Shi Renaissance Building Shanghai, 20031, P.R. China T: 1-800-578-6007
For more information, please visit: www.sandisk.com/enterprise
“The savings were enormous. We are now able to fully utilize the processors in our TSM servers. This allows us to cut our server footprint (and accompanying floor space, power and cooling costs) by two-thirds,” Geirr said. “At the same time, we’ve increased the speed of database backups and tasks like inventory expiration jobs, which makes our servers more responsive. Our customers have noticed the di!erence.”
Easy Implementation and Rapid Software Upgrade
Implementing the Fusion ioMemory cards proved much easier than upgrading to a SAN.
Geirr told us, “Adding a SAN would have required serious planning and thought toward disk architecture, and the physical upgrade would have taken days. It took 30-45 minutes to physically install the Fusion ioMemory cards and copying the databases was very fast.”
Front-safe also took this opportunity to upgrade from TSM 5.5 to 6.2 and discovered rapid upgrades were another unexpected benefit. “IBM estimates a 50-100GB upgrade will take one to three days on a disk-based system,” Geirr said. “The same upgrade on a SanDisk powered system finished in less than five hours.”
Summary
Implementing the Fusion ioMemory solution gave Front-safe the following benefits:• Query times from minutes to seconds• Tivoli expiration jobs from hours to minutes• 3x higher TSM workload• 3:1 server consolidation from improved workload• Easy implementation• 5x faster TSM software upgrade
About the Customer
Front-safe is a Danish-owned company in the JS Holding Group, which in total counts more than 100 employees. Front-safe is a dedicated and focused supplier of backup and archiving solutions, proactively protecting businesses of all types and sizes from data loss. Front-safe operates in Denmark with redundant data centers and o"ces in Aarhus and Copenhagen. Front-safe provides automated and secure remote online backup, disaster recovery and archiving solutions freeing its customers’ resources so they can focus on their core businesses.
The performance results discussed herein are based on internal Front-safe testing and use of Fusion ioMemory products. Results and performance may vary according to configurations and systems, including drive capacity, system architecture and applications.
©2014 SanDisk Corporation. All rights reserved. SanDisk is a trademark of SanDisk Corporation, registered in the United States and other countries. Fusion ioMemory, and others are trademarks of SanDisk Enterprise IP LLC. Other brand names mentioned herein are for identification purposes only and may be the trademarks of their respective holder(s).
80
GPFS
Thank You [email protected]
hzp://itblog.sandisk.com/ @SanDiskDataCTR @BigDataFlash © 2015 SanDisk Corpora]on. All rights reserved. SanDisk is a trademark of SanDisk Corpora]on, registered in the United States and other countries. InfiniFlash, Op]mus MAX, and Fusion ioMemory are trademarks of SanDisk Corpora]on. Other brand names men]oned herein are for iden]fica]on purposes only and may be the trademarks of their respec]ve holder(s).