CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong
Transcript of CEILING&WALL SYSTEMS - Flooring and Ceiling Products by Armstrong
CEILING&WALL SYSTEMS
Between us, ideas become reality® September 2012CI/SfB (35) Xy
Suspension Systems Catalogue 2013 / 2014
www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
SUMMARY ARMSTRONG SUSPENSIONSYSTEMS
Armstrong’s Philosophies 1Armstrong’s Commitment to the Environment 2CE Marking 3Armstrong Projects 4The Range 5
TECHNICAL INFORMATION 6 - 22Fire Tests 16Load Capacity Matrix 20
PRODUCT RANGEDESIGN OPTIONSAxiom Transitions 22Axiom Profiles 24Axiom Classic Canopy 26Axiom Knife Edge Canopy 28Axiom Circle & Curved 30Silhouette 15 XL2 32Interlude 15 XL2 34Microline 36
GENERAL APPLICATIONSPrelude 15 38Prelude 24 XL2 40Prelude 24 TLX 42Prelude Sixty2 44Prelude 35 XL2 46Bandraster 48System Z 50Drywall Grid System 52
CORRIDORDrywall Grid System Shortspan 54Prelude Sixty2 55
SPECIFIC APPLICATIONSClean Room 24 mm Grid System 56Corrosive Resistant 24 mm Grid System 58Seismic Solution 60LongSpan System 62
PERIMETER TRIM AND ACCESSORIESFlexible Perimeter Trim 64Perimeter Solutions - Mineral Ceilings 66Perimeter Solutions - Metal Ceilings 68Accessories 70
Designed forfast and easyinstallation
environment quality/CE marking product innovation service
1
ARMSTRONG’S PHILOSOPHIES
TOTAL CEILING SOLUTIONSThe suspension system product range forms an integral part ofArmstrong’s total ceiling solutions policy. Armstrong nowoffers its customers and specifiers a complete range of ceilingpanels including mineral, soft fibre, wood and metal and awider choice than ever of suspension systems. Armstrong canprovide solutions for all elements in today’s challengingconstruction environments.
QUALITYSuspension systems are manufactured for Armstrong both byits joint venture company WAVE (Worthington ArmstrongVenture) and through various alliances with other companieswho are regarded as specialists in their fields of engineering.WAVE operates on a global basis, and brings to its variousEuropean operations world class practice on the mosttechnologically advanced equipment.
INTEGRATIONSuspension systems are designed for integration withArmstrong's portfolio of ceiling products, mineral, soft fibre,metal, wood and special solutions.
SERVICESuspension systems are manufactured in three Europeanplants, strategically located to serve all our Europeancustomers. Additionally, both Armstrong and WAVE can drawupon their global manufacturing capabilities for both specialityproducts and manufacturing support.In addition to WAVE’s manufacturing sites, Armstrong stockssuspension systems in distribution centres throughout Europe.This allows our customers the convenience of mixed productshipments, combining suspension systems with otherArmstrong ceiling products, optimising bulk shipments directfrom their manufacturing locations.
WAVEWAVE has three manufacturing locations in Europe, three inthe USA including the facility in Aberdeen, Maryland which isone of the world’s largest grid facilities, plus one in China.
Metal ceiling plants
Mineral fibre plants
Grid plants
Distribution centres
STAFFORD
TEAM VALLEY
MUNSTERMOSCOW
MUMBAI
VALENCIENNES
MADRID
RANKWEILPONTARLIER
LAS VEGAS
BENTON HARBOUR
ABERDEEN / MALVERN
SHANGHAI
2 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
ARMSTRONG’S COMMITMENT TO THE ENVIRONMENT
Our environmental efforts in the life-cycle of our products start with design.
MANUFACTURING• Suspension system Main Runners and Cross Tees are rotary stitched
by a patented method to deliver extra strength and stability.• All in process scrap is recycled back into the process.• Suspension systems and panels are manufactured at several
locations, thereby reducing transportation costs and environmental impacts associated with transportation.
INSTALLATION• Integrate technology to reduce installation time.• Optimised packaging material - less waste on site.
• Up to 100% of the packaging is made from recycled material.
In several countries, we support the recollection of packaging.
MAINTENANCE• Minimal maintenance and easy to replace.• Armstrong has an expanding portfolio of sustainable
products, these include:
> Hot-dipped galvanised suspension systems providesuperior resistance to rust and corrosion.
DESIGN• Innovative design creates stronger sections.• Reuse of waste materials • Raw materials for ceilings are renewable and abundant in nature.• Recycled content varies by product:- Suspension system - contain 25% post-consumer recycled content
RECYCLE• Suspension systems contain up to 25% post-consumer recycled content• End of Life ceiling tile recycling scheme.
RETHINK PRODUCTS• Continuous development of innovative thin gauge products.
WARRANTY ON USE• A history of quality products.• Various warranty options are available on ceilings systems.
fi
fifi
fi
fi
fifi
3
CE Marking What is it ?CE stands for Conformité Européenne, which translatedliterally, means “European Conformity”. The CE mark is aproducts “passport” for entry into the EEA (EuropeanEconomic Area) and indicates that the product complies with the requirements of the applicable European Directive.
For construction products the European Directive is theConstruction Products Directive (89/106/ EEC), however, this is being replaced by the Construction ProductsRegulations (305/2011/EU) which will come into full force on 1st July 2013.
The CPD identifies the essential requirements for products(and total projects) such that they are fit for intended use as:
• mechanical resistance and stability;
• safety in case of fire;
• hygiene, health and environment;
• safety in use;
• protection against noise;
• energy economy and heat retention.
For suspended ceilings, the way in which we must testand communicate performance for these essentialrequirements has been defined in EN 13964 SuspendedCeilings – Requirements and Test Methods.
What does this mean?This standard identifies how the ceiling components must be tested against the essential requirements to identify aperformance classification. It also indicates how themanufacturer must ensure that their products maintain theselevels of performance on an ongoing basis.
On 1st July 2007, it becamemandatory for all suspendedceilings and accompanying suspension systems (in thescope of EN 13964) to carry the CE mark and theaccompanying essential requirement test information.
Since 1st July 2007, non-CE marked materials are no longersaleable into the EEA.
BRE BUILDING RESEARCH ESTABLISHMENTAt Armstrong, we’re proud to be a recognised pioneer in greenpractices, with successful methods to produce environmentallypreferable products, prevent pollution and reduce waste. We’re the only UK mineral ceiling manufacturer with a BRE Ecopoint profile – an external certification of our compliance with ISO 14041 and ISO 21930 standards. Our Ecopoint score in 2007 was 0.10, a significant improvement on 2004, and we’re working on lowering it even further.
4
ARMSTRONG PROJECTS
Armstrong World Industry (USA) - Axiom Circle Canopy
Uttoxeter Cinema (UK) -Coloured Prelude 24
5
Telefonica Center (SP) - Bandraster
Concordia Hotel (IT) - Axiom C Canopy Dutch Technology Leiden (NL) - System Z
Hospital Ruzomberok (SK) - Clean Room Grid.Medis Office (SI) - Silhouette
Lothar Meyer School (DE)
6 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
THE SUSPENSION RANGE
The suspension systemsinclude a full range ofsolutions for all ceilingsuspension requirements.
• General applications, a range of standard Prelude 24mm and Prelude 15mm grid systems, Bandraster and Prelude Sixty2 for longer spans. Drywall Grid Systems are available for plasterboard ceilings.
• Designer options including the minimalist grid Silhouette, Microline, Interlude and the Axiom range.
• Specific applications, for clean room and higher humidity environments.
• Perimeter trims and accessories, for most applications.
We also include our comprehensive programme of special size options that is available in most ranges. A range of either stab or hook systems are available to meet the mechanical preferences of the installer.
To complete the portfolio we also offer a technical test programme that provides fire, loadings and environmental accreditation.
Suspension systems are designed for use with a wide variety of Armstrong ceiling products, mineral, soft fibre, metal, wood and special solutions.
Peakform is an innovative design for Main Runners and Cross Tees. The taller Peakform profiles are engineered to create a stronger, more stable suspension system making installation both faster and easier.
Superlock is an industry first staked-on clip for Main Runners which provides tighter, secure bulb-to-bulb connections; connections are confirmed by an audible click; Main Runners are easily disconnected and reconnected laterally.
7
WHERE INNOVATION MEETS PERFORMANCE
VOICE OF THE CUSTOMERCustomer input is an extremely valuable part of our productinnovation progress. Armstrong hold regular voice ofcustomer work sessions to help develop the most innovativeproducts and systems to meet the customer’s needs.
HOT DIPPED GALVINISED STEEL:Inhibits red rusting better and longer than electro galvanised orpainted systems
• Installation of grid can start before the building is enclosedor HVAC system is operational.
• Long term system performance because entire system ishot dipped galvanised steel.
THIN GAUGE TECHNOLOGY:Up to 50% lighter carton weightthan the competition enableseasier handling on site, plus theadded benefit of the Peakformbulb allows easy cutting of the grid.
DESIGNER GRIDSArmstrong’s designer range, Silhouette, Microline, Interlude, AxiomSystem and Axiom Canopies provide aesthetically enhanced grids.Silhouette creates a level ceiling surface, providing a flushappearance while Interlude gives a clean sophisticated visual thatis created by the unique double reveal. Axiom Profiles andTransitions provide an aesthetic solution for changes in level anda flush transition with plaster margins. Axiom Canopies are aperimeter trim system designed to create “ceiling clouds” inconjunction with full size tiles. Microline is a steel based grid withaluminium extrusion. The exposed sleeve provides a clean and crispvisual plus a practical fluted reveal for flexibility in partition fixing and relocation.
OTHER SYSTEMSOur extensive range of performance grids also includesBandraster, Prelude Sixty2, Prelude 35, System Z andLongSpan. Specific grid solutions such as Clean RoomGrid, Seismic Grid and Corrosive Resistant grid completesArmstrong's suspension solutions.
PHYSICAL DETAILAll grids are made from double-web galvanised steel with asurface finish of baked polyester paint.
STITCHINGAll Prelude componentsfeature a unique“stitched” construction.The two metal layers ofthe vertical web aremechanically locked together in a sophisticated in-lineprocess. Stitching enhances the torsional resistance andgeneral “feel” of the Prelude components.
FULL RANGE OF ACCESSORIESAND PERIMETER SOLUTIONS
Suspension systems are offered with a completerange of commonly required accessories andperimeter solutions.
8 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
PRELUDE UNIVERSAL MAIN RUNNERThe Prelude Universal Main Runner supports the installation of eitherhook/butt cut or stab/override Cross Tees from one simple inventory of MainRunners. The universal system is available in Peakform design in both 24mmand 15mm widths. The Peakform Universal Main Runners feature a firm, quick and easyassembled Main Runner to Main Runner / bulb-to-bulb connection. Metricsized Main Runners are slotted at 100mm centres for more flexibility. Slots aremachined to receive positive and accurate assembly of either Prelude TL andTLX (hook installation) or Prelude XL2 (stab installation) Cross Tees.
The staked-on Superlock clip allows for Main Runners to be disconnectedand reconnected laterally in low-clearance areas or in the middle of a room.
TL
TLX
PRELUDE XL2
WHERE INNOVATION MEETS PERFORMANCE
ARMSTRONG SYSTEMS
SEISMIC Rx® SYSTEMArmstrong Seismic Rx® System is a fully and independently tested approach to achieving ceiling installations that can withstand the forces associated with significant seismic activity or other severe events. In addition to earthquakes, there are several other industries withassociated risks (e.g. Blast protection) where the use of Seismic Rx®System will provide additional protection for the ceiling e.g.• Nuclear installations• Defence establishments• Chemical installations• Transport installations (with intermittent vibrations)The Seismic Rx® system provides the additional security required forseismic resistance using specifically designed elements for minimisedinstallation complexity with maximum performance.
9
PRELUDE XL2 “CLICK” INSTALLATIONPrelude XL2 Cross Tees in both 24mm and 15mm widthsfeature an advanced stab system that locates with an audible“click”, ensuring a solid installation at all times. The stab endis precision stamped from a separate piece of high gradesteel permitting an increased accuracy and economy ofproduction over the more conventional integral forming of theCross Tee ends. A selected range of standard Prelude 15/24XL2 Cross Tees feature the new Peakform design.
The Cross Tees are inserted to the right of each otherthrough the Main Runner slots and easily pushed home.
PRELUDE TLXTLX is a new highly engineered staked-on hook system, witha patented clip. Its unique steel-based composite materialand shape provide a stronger and level connection, animproved fire performance and an increased overallstability.TLX Cross Tees are quicker and easier to cut due tothe Peakform section.
When the TLX Cross Tees are inserted to the right of eachother through the Main Runner slots, the TLX clip provides amore secure installation.
PRELUDE TL “HOOK” INSTALLATIONPrelude TL Cross Tees in 15mm width feature an integrallyformed hook nose. This popular installation system has beena feature of Armstrong suspension systems for over 20 yearsand its proven ease of assembly and precise butt cut jointhas been a favourite of installers. Cross Tee alignment isensured by locating the tees to the right hand side of theadjoining section.
10 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
STANDARD COLOURS
Armstrong suspension system components are manufactured in a range of colours and metal finishes including Global White tocomplement Armstrong ceiling tiles. For complete information call Armstrong Technical Sales.
GLOBAL WHITE SILVER GREY CARRARA PLATINUM BLACK WHITE GLOBAL WHITE BRASS CHROME WHITE GALVANISED BLACK/WHITE (GW) RAL 9006 (SG) (CA) (PN) (BK) RAL9010 (WR) (GW) (BS) (CE) RAL9010 (WR)
Prelude 24 TLX
Prelude 24 XL2
Prelude 15 XL2/TL
Silhouette XL2 6mm
Silhouette XL2 3mm
Interlude
Bandraster
Prelude 35
Prelude Sixty2
Corrosive Resistant
Clean Room Grid
Axiom System
Steel based capping Other than Steel based
Painted perimeter trim items are available in Global White and capped angle T 1924 CA is available in all colours except black/white and galvanised.Please contact Armstrong Technical Sales Group for further details.
11
COLOUR PALLET
• Stimulate your imagination to create vibrant interior spaces using custom colour solutions.• Choice of more than 180 custom colours upon request.• Available for Prelude 15 and Prelude 24 and specific perimeter trims.
DETAILS
15mm 24mm
15 mm Cross Teeand Main Runner
24 mm Cross Teeand Main Runner
Colour Selection Due to printing limitations, shade may vary from actual product.
*Matt finish items are available as a special order.RAL CLASSIC: Important notice: This ORIGINAL RAL colour chart (card) has gone through stringent quality testing by RAL. Only the use of the individual cards of the registers RAL840-HR (semi matt finish) and RAL 841-GL (gloss finish) will guarantee a reliable manufacture and control of RAL Colours.
RAL 1000 RAL 1001* RAL 1002 RAL 1003 RAL 1004 RAL 1005 RAL 1006 RAL 1007* RAL 1011 RAL 1012 RAL 1013* RAL 1014 RAL 1015*
RAL 1016 RAL 1017 RAL 1018 RAL 1019* RAL 1020 RAL 1021* RAL 1024 RAL 1027 RAL 1028 RAL 1032 RAL 1033 RAL 1034 RAL 2000*
RAL 2001 RAL 2002* RAL 2003 RAL 2004* RAL 2008 RAL 2010 RAL 2011 RAL 2012 RAL 3000* RAL 3001 RAL 3002* RAL 3003 RAL 3004
RAL 3005 RAL 3007 RAL 3009 RAL 3011 RAL 3012 RAL 3013 RAL 3014 RAL 3015 RAL 3016 RAL 3017 RAL 3018 RAL 3022 RAL 3027
RAL 3031 RAL 4001 RAL 4002 RAL 4003 RAL 4004 RAL 4005 RAL 4007 RAL 4008 RAL 4009 RAL 5000 RAL 5001 RAL 5002 RAL 5003*
RAL 5004 RAL 5005 RAL 5007 RAL 5008 RAL 5009* RAL 5010* RAL 5011 RAL 5012* RAL 5013 RAL 5014 RAL 5015* RAL 5018 RAL 5019
RAL 5020 RAL 5021 RAL 5022 RAL 5024 RAL 6000 RAL 6001 RAL 6002 RAL 6003 RAL 6004 RAL 6005 RAL 6006 RAL 6007 RAL 6008
RAL 6009 RAL 6010 RAL 6011* RAL 6012 RAL 6013 RAL 6014 RAL 6015 RAL 6016 RAL 6017 RAL 6018 RAL 6019 RAL 6020 RAL 6021
RAL 6022 RAL 6025 RAL 6026 RAL 6027 RAL 6028 RAL 6029 RAL 6032 RAL 7000 RAL 7001* RAL 7002 RAL 7003 RAL 7004 RAL 7005
RAL 7006 RAL 7008 RAL 7009 RAL 7010 RAL 7011 RAL 7012* RAL 7013 RAL 7015 RAL 7016* RAL 7021* RAL 7022 RAL 7023 RAL 7024
RAL 7026 RAL 7030* RAL 7031* RAL 7032* RAL 7033 RAL 7034 RAL 7035* RAL 7036 RAL 7037 RAL 7038* RAL 7039 RAL 7040* RAL 7044*
RAL 8000 RAL 8001 RAL 8002 RAL 8003 RAL 8004 RAL 8007 RAL 8008 RAL 8011 RAL 8012 RAL 8014* RAL 8015 RAL 8016 RAL 8017
RAL 8019* RAL 8022 RAL 8023 RAL 8024 RAL 8025 RAL 8028 RAL 9001* RAL 9002* RAL 9003* RAL 9004 RAL 9005* RAL 9010* RAL 9011*
RAL 9018* RAL 1023 RAL 2009 RAL 3020 RAL 4006 RAL 5017 RAL 6024 RAL 7042 RAL 7043 RAL 9016* RAL 9017
12 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
PRODUCT SELECTORby application areas
PRODUCT SELECTORby edge detail compatibility
Area Suspension system solution
Open spaces Axiom Canopy (C/KE/Circle/Curved)Axiom TransitionsBandraster
Reception areas Axiom TransitionsAxiom ProfilesSilhouette 15 mmMicroline 15 mmInterlude 15 mm
Meeting rooms / Individual offices Prelude 24 mmPrelude 15 mm
Circulation areas System Z Microline 15 mmPrelude Sixty2
Retail outlets / industrial manufacturing Prelude 35 XL2
Humid areas Prelude 24 Corrosive Resistant
Healthcare environments Clean Room Grid
Axiom Silhouette Interlude Microline Prelude Prelude Prelude Prelude Sixty2 Prelude Clean Room Corrosive Bandraster System ZTransitions/ 15 15 15 24 XL2 24 TLX 35XL2 ResistantProfiles
Mineral
Vector • • • •
MicroLook • • •
MicroLook BE • • • •
Tegular • • • • • • •
Board • • • • • • • •
SL2 • • • • • •
Metal
Metal Axal Vector • • •
Metal MicroLook 8 • • • • •
Metal MicroLook 16 • •
Metal Tegular 2 • • •
Metal Tegular • • • •8, 11F or 16
Metal Board • • •
13
TECHNICAL ICONS
Colour Pallet
Accessories
Peakform
Perimeter Trim
Specific Applications/Healthcare Environments
General Applications Designer Grid
Corridor
14 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
HEALTH AND CLEANLINESS
Did You Know... ?It’s all about Air Quality control:■ The air penetrating the Clean Room can be filtered
depending on the size of the undesired elements.
■ Air can be recycled up to 60 times per hour for the total volume of the space.
■ New air is also introduced to avoid a build up in the concentration of CO2 and maintain enough oxygen for the people working there.
■ Operators in a clean room have to wear equipment such as a clean room suit, caps, gloves, shoe protectors and masks.
■ There are 2 types of rooms:
- rooms with over-pressure, to avoid pollutants from entering (dust, bacteria,…)
- rooms with negative pressure, to avoid various contaminants from escaping to the outside (viruses, bacteria, spores,…).
■ Building materials used in such spaces shall not have a negative impact on the pursuance of cleanliness and should preferably contribute actively to a better
CLEAN ROOMA clean room is a space or a series of spaces where the concentration of particles is controlled in order to minimise theintroduction, generation, retention of particles inside, generally for a specific industrial or research objective, as well as inhealthcare environments. Parameters such as temperature, humidity and relative pressure are also maintained at a preciselevel, as defined in ISO 14644-1.• Clean rooms are classified ISO 1 (cleanest) to ISO 9 depending on the number of particles measured.• The performance is tested to ISO 14644-1 which determines the particle cleanliness class. Although US Federal
Standard 209E has been officially withdrawn, it is continuously used as a reference.
The following table shows the equivalence between the 2 standards.
HEALTHCARE PREMISEIn healthcare premises, it is of critical importance to avoid hospital acquired infections.According to the level of risk, the necessary clean room performance will vary, generally between ISO 5 and ISO 8.All products below:• can be used in ISO 5 environments and are certified against ISO 14644-1;• inhibit growth of bacteria, moulds and yeasts tested against norms NF S 90-351, France, and JIS Z2801, Japan.
Maximum Number of Particles in Air ISO Class (particles in each cubic metre equal to or greater than the specified size)
Particle size > 0.1µm > 0.2 µm > 0.3 µm > 0.5 µm > 1 µm > 5 µm
ISO Class 1 10 2 -
ISO Class 2 100 24 10 4 -
ISO Class 3 1 000 237 102 35 8 Class 1
ISO Class 4 10 000 2 370 1 020 352 83 Class 10
ISO Class 5 100 000 23 700 10 200 3 520 832 29 Class 100
ISO Class 6 1 000 000 237 000 102 000 35 200 8 320 293 Class 1 000
ISO Class 7 352 000 83 200 2 930 Class 10 000
ISO Class 8 3 520 000 832 000 29 300 Class 100 000
ISO Class 9 35 200 000 8 320 000 293 000 Class 1 000 000
US FederalStandard 209E
Some examples of spaces and system solutions:
TYPE OF SPACE CONSTRAINTS SYSTEM SOLUTION* LEVEL OF PERFORMANCE
Operating Theatre Fully air-tight Metal Bioguard Plain Clip-In ISO 3 Flush surface finish with appropriate silicone or mastic joint High pressure water cleanable Anti-microbial
MRI Non-magnetic CLEAN ROOM grid with plastic ISO 5 hold-down clips & Clean Room FL Anti-static
Anti-microbial CLEAN ROOM grid with plastic ISO 5 hold-down clips & Bioguard Acoustic Bioguard treatment Intensive Care Anti-microbial Clean Room grid with plastic hold-down ISO 5Recovery Room Good air-tightness clips Bioguard Acoustic or Metal Bioguard WashableMaternity Good acoustical environment Extra Microperforated Rg 0701 with 0.65 �w sound absorptionLaboratory Premium B15Pharmacy
* Subject to local regulations. Please check with your Armstrong Technical Sales team.
15
Did You Know... ?System solutions for the pharmaceutical,food and manufacturing industry can befound in our brochure “Solutions for CleanRoom Environments”.
BIOGUARD products have been especiallydesigned for the healthcare sector.
The BIOGUARD paint treatment has additionalactive components which reduce the colony sizeof virulent strains of bacteria, moulds and yeasts.
BIOGUARD products achieve ISO 5 to ISO 3 inaccordance with ISO 14644-1.
BIOGUARD paint has enhanced resistance todisinfectants.
Clean Room Bioguard Bioguard Clean Room FL Metal Bioguard Metal Bioguard Grid Plain Acoustic Extra Plain Microperforated Rg 0701 with Premium B15
Classification Zone 1, 2 & 3 Zone 1, 2 & 3 Zone 1, 2 & 3 Zone 1, 2 & 3 Zone 1, 2 & 3 Zone 1, 2, 3 & 4NF S 90-351
Particle ISO 4 ISO 5 ISO 5 ISO 5 ISO 5 ISO 3cleanliness class
Material Aluminium Mineral Mineral Mineral Steel with mineral Steel acoustic infill
Surface PVC Bioguard paint Glass veil with Polyester film EXTRA PLAIN Bioguard paint MICROPERFORATED with Bioguard Rg 0701 with polyester powder Bioguard polyester paint powder paint
Resistance Quaternary Ammonium, Hydrogen Peroxide, Chlorine * Quaternary Ammonium,to disinfectants* Hydrogen Peroxide, Chlorine
Grid and tiles for Clean Room environments
GRID MINERAL METAL
* Not tested
16 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
FIRE PERFORMANCES
The harmonisation of technicalstandards within Europe, and theintegration of EN13964 (Suspendedceilings – requirements and testmethods) into national legislation,means that there is now one series ofharmonised European test methodsand classifications for the reaction tofire of suspended ceilings.
These new reaction to fireclassifications, or ‘Euroclasses’, aredefined in EN13501-1:2007.
The ‘Euroclasses’ have replaced theold national fire reaction ratings forshowing the performance of ceilings inorder to meet the Construction
Products Directive and nationalbuilding regulation requirements forinternal linings.
As reaction to fire is one of theessential safety requirements identifiedfor suspended ceilings, the Euroclassclassification is one of the mandatoryelements on the CE mark forsuspended ceiling tiles and grids.
The ‘Euroclasses’ rate from A1through to F, with A1 being the bestreaction to fire performance and F theworst.
Each member state then sets theperformance level required for differentareas and building types within their
own building regulations.
Depending upon the reaction to firetest(s) conducted, the rating mayinclude an additional classifications forsmoke production and flamingdroplets. Smoke and flaming dropletsare regulated in some Europeancountries.
Smoke production is rated from s1(the least smoke produced) to s3 (nolimit to amount of smoke produced).
Flaming droplets is rated from d0 (noflaming droplets) to d2 (no limit toflaming droplets).
Throughout Europe, there is arequirement for a building’s structureto be protected from fire. This isprimarily for the structure to remainstable during a fire to allow theoccupants to escape and also toenable fire fighters to work withoutthreat of the building’s collapse. Theduration of the required protection willusually depend upon the height of,and location within, the building (i.e.typical floor, basement, roofconstruction etc), whether there is anyactive methods of fire protection(sprinklers etc) and the type ofconstruction to be protected (steelbeams, timber or mezzanine floorsetc).
A fire protecting suspended ceilingsystem is one of several important
methods of providing the fireprotection which fire degradableelements of the structure require.Ceilings can be used to enable a floorconstruction to meet the duration ofprotection required by the buildingregulations that it could not necessarilyprovide on its own.
There are many national test methodsfor establishing the structural fireprotection performance of asuspended ceiling system, as well asseveral European norms which areacceptable in most Europeancountries. The performance achievedduring testing will be classified in termsof the duration of protection given,typically this in accordance withEN13501-2:2007 for European tests.However, there is not yet one singleEuropean test method which isacceptable to all member states.
Untested products may be assessedby reference to the product attributes
and comparison to similar testedproducts, provided this is supportedby an assessment report from arecognised fire expert and should beprovided with the base test report thatdetails how the product should beinstalled to achieve the assessedperformance. The location and type ofvarious service elements such aslighting fittings, smoke detectors etc,are infinite and the designer andinstaller must satisfy themselves thatthey can be integrated withoutreducing the tested performance ofthe ceiling system. This will usuallyrequire a test report from the fittingmanufacturer or an assessment issuedby the fire authorities. Without thesedocuments the designer or installermay assume an everlastingresponsibility for the fire safety of thebuilding and occupants.
The complete construction andassembly of the test installation isimportant to the success of the test,and Armstrong test many ceiling tilesfor their structural fire performance,but always on Armstrong grid.
There are many other details of thetest construction that must beunderstood and adhered to. Theseinclude:
• main runner and hanger centres
• the type of top fixings and how the hangers are attached to them
• the minimum depth of the ceiling void
• what % of the floor design load is tested
• whether ceiling tile hold-down clips were used.
These details must be included in theinstallation if the tested performance is
to be realised and they should betaken into account when writingspecifications for ceilings intended toprovide structural fire protection.
In the UK the fire performance of floorstructures protected by Armstrongceiling tile and grid systems is given inthe fire assessment document 173816.
This document is based on a largenumber of fire tests conducted onvarious Armstrong ceiling tile and gridtypes. It provides an assessment ofthe performances attainable whenvarious Armstrong tile and gridsystems are installed in accordancewith the appropriate base fire test andthe permitted installation variationsfrom that base test.
The tables opposite give a summary ofthe performances achievable as statedin the assessment document and arecorrect at the time of going to print.
As products may be modified orretested it is essential that theirvalidity is always checked prior toinstallation. Therefore, the currentversion of the assessmentdocument 173816 and the relevantbase test report should always beconsulted prior to the installationof a floor construction to beprotected by an Armstrong ceilingsystem.A full document is always required andmust be read and any limitationsunderstood. Abridged versions mustbe regarded as undesirable as they willnot show the full test details andconstruction.
All Armstrong classificationdocuments are freely available onrequest from the ArmstrongTechnical Sales team.
REACTION TO FIRE
STRUCTURAL FIRE PROTECTION
17
*AFTBF = an aluminium foil, black tissue faced acoustic pad
Assessed Performance Under Structural Steel Beams - Base Test Report: 134086 (70995 for Clip-In)
Assessed Performance Under Timber Floors - Base Test Report: 167751
Assessed Performance Under Mezzanine Floors - Base Test Report: 120559
Board Tegular MicroLook Tegular 2 Clip-In 3mm CommentsUltima 90 minutes 60 minutes 60 minutes n/a n/a Includes 500 x 500 and 1200 x 300 MicroLook ULTIMAUltima dB 60 minutes 60 minutes 60 minutes n/a n/aUltima OP 30 minutes n/a n/a n/a n/aPerla 60 minutes 60 minutes 60 minutes n/a n/aBioguard Acoustic / Bioguard Plain 60 minutes 60 minutes 60 minutes n/a n/aDune dB 60 minutes
60 minutes60 minutes60 minutes
60 minutes n/an/a
n/an/a
Fine FissuredDune Supreme 60 minutes 60 minutes 30 minutes
30 minutes
n/a n/a Includes Colortone BlackPlain 60 minutes 60 minutes 30 minutes n/a n/a Does NOT include GRAPHISCirrus 60 minutes 60 minutes 30 minutes n/a n/a Does NOT include any CIRRUS Design tilesMezzanine DL 100 60 minutes n/a n/a n/a n/aMetal Plain + Premium B15 or PAD 60 minutes 60 minutes 60 minutes 60 minutes n/a 8mm and 16mm returns. 18mm 100kg/m3 AFBTF* padMetal Standard Perforated Rg 2516 + Premium B15 or PAD
60 minutes 60 minutes 60 minutes 60 minutes n/a 8mm and 16mm returns. 18mm 100kg/m3 AFBTF* pad
Metal Microperforated Rd 1522 + Premium B15 or PAD
60 minutes 60 minutes 60 minutes 60 minutes n/a 8mm and 16mm returns. 18mm 100kg/m3 AFBTF* pad
Metal Extra Microperforated Rg 0701 + Premium B15 or PAD
60 minutes 60 minutes 60 minutes 60 minutes n/a 8mm and 16mm returns. 18mm 100kg/m3 AFBTF* pad
Metal Plain + PAD n/a n/a n/a n/a 30 minutes 600 x 600 only. 40mm 45kg/m3 AFBTF* pad
Metal Standard Perforated Rg 2516 + PAD n/a n/a n/a n/a 30 minutes 600 x 600 only. 40mm 45kg/m3 AFBTF* pad
Metal Microperforated Rd 1522 + PAD n/a n/a n/a n/a 30 minutes 600 x 600 only. 40mm 45kg/m3 AFBTF* pad
Metal Extra MicroperforatedRg 0701 + PAD n/a n/a n/a n/a 30 minutes 600 x 600 only. 40mm 45kg/m3 AFBTF* pad
Board Tegular MicroLook Tegular 2 Clip-In 3mm CommentsUltima 60 minutes 60 minutes 60 minutes n/a n/a
Main runners at 600mm centres onlyUltima dB 60 minutes 60 minutes 60 minutes n/a n/aDune dB 60 minutes 60 minutes 60 minutes n/a n/a
Mezzanine DL 100Dune Supreme
n/a n/a n/an/a
n/an/a n/a
n/aFine Fissured n/a n/a n/a n/a n/aUltima / Ultima dB 30 minutes
30 minutes
30 minutes
30 minutes
30 minutes n/a n/aPerla 30 minutes 30 minutes n/a n/a n/aSierra 30 minutes 30 minutes n/a n/a n/aBioguard Acoustic / Bioguard Plain 30 minutes 30 minutes n/a n/a n/aFine Fissured 30 minutes 30 minutes n/a n/a n/a Includes Colortone BlackPlain 30 minutes 30 minutes n/a n/a n/a Does NOT include GRAPHISCirrus 30 minutes 30 minutes n/a n/a n/a Does NOT include any CIRRUS Design tiles
Board Tegular MicroLook Tegular 2 Clip-In 3mm CommentsUltima / Ultima dB 60 minutes 60 minutes 30 minutes n/a n/aUltima dB 60 minutes 60 minutes 30 minutes n/a n/aDune dB 60 minutes 60 minutes 30 minutes n/a n/a
Mezzanine DL 100Dune Supreme
60 minutes n/a n/an/a
n/an/a
n/an/a
Perla 30 minutes
30 minutes
30 minutes
30 minutes
n/a n/a n/aSierra 30 minutes 30 minutes n/a n/a n/aBioguard Acoustic / Bioguard Plain 30 minutes 30 minutes n/a n/a n/aFine Fissured 30 minutes 30 minutes n/a n/a n/a Includes Colortone BlackPlain 30 minutes 30 minutes n/a n/a n/a Does NOT include GRAPHISCirrus 30 minutes 30 minutes n/a n/a n/a Does NOT include any CIRRUS Design tiles
Building Regulations area (non-residential) Euroclass Old classification
Circulation areasA1 Non-combustibleA2-s3, d2 Limited CombustibilityB-s3, d2 Class 0
Other Rooms (> 30 m2)C-s3, d2
Class 1
Small Rooms (≤ 30 m 2) Class 2D-s3, d2 Class 3
(Product cannot be used) E-d2, F Class 4
Building Regulation performance table – internal linings
18 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
INSTALLATION & MAINTENANCE
SAFETYArmstrong’s commitment on safety concerns each and every step of our business:
• in our plants & offices, we have implemented rigorous safety policies and procedures to help minimise risk
• for our products, for which we ensure compliance with appropriate European and local safety regulations.
• on the jobsite, safety is crucial for our partners: Armstrong therefore recommends the handling, installation & maintenance of our solutions in accordance with the European standards and/or local regulations, for the safety of the installers & of the end users.
GENERAL ADVICE
Installation of suspended ceiling systems should be carried out inaccordance with Armstrong's current manufacturer's recommendations.
For grid systems there are some specific points that should beconsidered:
- The appropriate type of Cross Tee for the ceiling tile edge detail must be considered.
- The grid systems should be installed in such a way that the loadbearing performance of the grid is not exceeded.
- 'Dynamic' service fittings should be independently supported so notto transfer vibration into the suspension system.
- Armstrong recommend the use of the 'ladder formation' and all our loading data is based on the 'ladder formation'. Using the 'H-formation' will give greater deflection for a given load.
Ladder formation H formation
Yes No
19
INSTALLATION & MAINTENANCE
POST INSTALLATIONAfter the installation of a suspended ceiling system it is important to ensure that it is properly maintained and that anyadditional works are not detrimental to the performance of the ceiling installation. Maintenance operations must only beundertaken after the technical impact on the ceiling system has been completely evaluated. For example, hangers should notbe removed, adapted or bent without fully understanding the consequences and taking any appropriate mitigating actions.
Armstrong suspension systems do not need any more maintenance than normal painted metal surfaces. However, if cleaningis required dust and superficial dirt can easily be removed with a soft brush or a vacuum cleaner with a brush attachment.For more stubborn marks a lightly dampened cloth or sponge can be used, although never use abrasive products.
Some companies specialise in chemical cleaning solutions. These should only be undertaken after a test on a small hiddenarea of grid proves acceptable.
Most Armstrong suspension systems can be redecorated, however, consideration should be given to the effect on the firereaction performance of the grid. Ceiling tiles should be removed, however, the grid can usually be painted in situ. If a firm ofprofessional decorators is used, assurances should be sought that the necessary performances will be maintained. It shouldbe noted that any repainting would invalidate Armstrong's warranty for the product.
For a copy of Armstrong's Suspension Systems Calculation Guide, please contact Armstrong Technical Sales.
Min 100 mm
2
3
300 mm
1 B
B
A
800
600 1000 A
M
2
51200 mm
6
4
1200 mm1200 mm
Max 600 mm
8
9
7
11
A /B
A/B
12
10
1. Planning grid layout 2. Mark the perimeter trim lines 3. Installation of perimeter trims
4. Mark hanger positions 5. Installation of hangers 6. Positioning Main Runner slots
7. Installation of Main Runners 8. Cross Tees installation right to right 9. Cutting Cross Tees
10. Installation of tiles 11. Measure and cut perimeter tiles
12. Re-tegulating Tegular or MicroLook tiles
B (Main Runner)
B (Main Runner)
20 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
LOAD CAPACITY MATRIX
Loading is an important property of suspended ceiling grid systems both for the mechanical safety of the suspendedceiling and its visual appearance.
In the EEA, table 6 of the suspended ceiling product standard, EN 13964:2004+A1:2006, defines 3 classes ofdeflection, the best being Class 1 which is L/500 (but no greater than 4mm).
The test method on which the European calculations of loadbearing capacity are based upon is also defined in EN13964, and considers the influence of both deflection and bending moment.
The individual product pages in the second half of this brochure include a table giving the maximum uniformdistributed load, based on different hanger centres, in accordance with Class 1 deflection, as defined in EN13964:2004 + A1:2006.
For markets outside of the EEA different deflection limits are sometimes required. The tables on this page show themaximum uniform distributed load for the deflection limits shown, but taking into account deflection only. Thesevalues are calculated based upon load values determined from laboratory tests in accordance with the EN 13964test method.
For longer spans, some of the criteria shown on this page may give quite large deflection values. Armstrongrecommends a maximum of 4mm deflection between points of suspension for all grid components, irrespective ofspan, for aesthetic reasons. Therefore the numbers in the tables on this page are the maximum loads permitted tomeet the give a deflection criteria (such as L/400) but up to a maximum value of 4mm.
System Load Summary (1200 x 1200 layout) - Max Load kg/m2 - Deflection factor only
System Main Runner Primary Secondary L/500 L/400 L/360 L/300 L/250 Cross Tee Cross Tee
Prelude 24 XL2 314032 A 313051 B 312021 A 13,3 16,8 18,8 22,7 22,7
Prelude 24 TLX 314032 A 133031 132031 13,3 16,8 18,7 22,7 22,7
Prelude 15 XL2 304033 A 303033 B 302033 B 13,1 16,5 18,5 22,3 22,3
Prelude 15 TL 304033 A 103033 A 102033 A 13,1 16,5 18,5 22,3 22,3
Microline CS 25 42 92 WR CS 25 30 42 WR CS 25 20 42 WR 12 15 17 20.5 20.5
Silhouette 15 XL2 804042 G 803042 G 802042 G 11,4 14,4 16,1 19,5 19,5
Interlude 15 XL2 614042 G 613042 G 612042 G 14,5 18,3 20,4 24,7 24,7
Prelude 35 XL2 224042 243042 242042 13,9 17,7 19,8 24 24Prelude 24 Corrosive
284042 143032 142032 13,3 16,8 18,7 22,7 22,7Resistant - TLX
Clean Room 24 EA794044 EA793044 EA792044 12,8 16,3 18,2 22,1 22,1
1200mmspacing
1200mmCross Tees
MRMR
600mm 1
Class Maximun deflection in mmA
1 LB / 500 and not greater than 4,02 LB / 3003 No limit
A The maximun deflection is the accumulative value of the deflection of the substructure component and the deflection of the membrane component.
B L is the span in mm between the suspension components or the suspension points.
21
System Load Summary (1200x1800 layout) - Max Load kg/m2 - Deflection factor only
System Main Runner Primary Secondary L/500 L/400 L/360 L/300 L/250 Cross Tee Cross Tee
Prelude 24 XL2 314032 A 313431 A 312021 A 6,5 7,3 7,3 7,3 7,3(1800 span)Prelude 24 TLX
314032 A 133432 132031 6,5 7,3 7,3 7,3 7,3(1800 span)
System Load Summary (1800x1800 layout) - Max Load kg/m2 - Deflection factor only
System Main Runner Primary Secondary L/500 L/400 L/360 L/300 L/250 Cross Tee Cross Tee
Prelude Sixty2 24 - XL2 404093 G 313431 A 312021 A 6,5 7,3 7,3 7,3 7,3
Prelude Sixty2 24 - TLX 404093 G 133432 132031 6,5 7,3 7,3 7,3 7,3
1200mmspacing
1800mmCross Tees
MRMR
600mm 1
1800mmspacing
1800mmCross Tees
MRMR
600mm
22 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
Des
ign
Opt
ions AXIOM TRANSITIONS
T 3208 G (1) Axiom Transitions for 3000 50 10 30,00 11,80 36 Tegular/MicroLook
T 3219 G (1) Axiom Transitions channel 3000 50 10 30,00 17,10 36
T 3215 G (1) Axiom Transitions angle 3000 50 10 30,00 15,00 36
T 3210 G (1) Axiom Transitions for 3000 50 10 30,00 11,80 36 Vector tiles
T 3225 G (1) Axiom Transitions plasterboard 3000 50 10 30,00 11,30 36 perimeter trim
Item Nr. Description Dimensions Content / Carton Weight / Carton Cartons / Pallet length (mm) height (mm) pcs lm kg
Axiom Transitions
A 321 G Axiom Transitions suspension clip – straight 79 100 2,10
A 322 G Axiom Transitions suspension clip – angled 62 100 2,10
A 340 G Axiom universal corner clip - 100 2,10
A 338 G Axiom universal splice plate - 100 2,10
A 339 G Axiom universal T bar connector clip - 100 2,10
A 344 G Axiom universal hanging clip - 100 2,10
Item Nr. Description Dimensions Content / Carton Weight / Carton height (mm) pcs kg
25 15
11
50
25 15
8
50
25 19 15
15
50
25 15
15
35
25 15 15
15
50
(1) Also available in colour RAL 9010 (WR).
Note: As Axiom is an aluminium extrusion it should not be used in ceiling assemblies where structural fire protection is required.
All measurements in millimetres. All sizes are nominal.
Accessories for Axiom Transitions
The 5 sections are designed to provide a flush transition between plaster margin and mineral, metal or wooden suspended ceilings.
79 mm
62 mm
A 321 G
A 322 G
A 338 G
A 339 G
A 340 G
23
Des
ign
Opt
ionsAXIOM TRANSITIONS
System Drawing
24 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
AXIOM PROFILES
Item Nr. Description Dimensions Content / Carton Weight / Carton height (mm) pcs kg
52 42 06 G (1) Axiom Profiles 50 mm 3000 50 5 15,00 7,80 60
54 42 06 G (1) Axiom Profiles 100 mm 3000 100 5 15,00 11,20 36
56 42 06 G (1) Axiom Profiles 150 mm 3000 150 5 15,00 14,70 30
58 42 06 G (1) Axiom Profiles 200 mm 3000 200 5 15,00 17,80 24
55 14 11 G (1) Axiom Vector Profiles 112 mm 3000 112 5 15,00 12,20 15
T 3213 H (1) Profile plasterboard trim 3000 18,5 10 30,00 5,80 36
Item Nr. Description Dimensions Content / Carton Weight / Carton Cartons / Pallet length (mm) height (mm) pcs lm kg
Axiom Profiles
Accessories for Axiom Profiles
A 334 G (1) Axiom Profiles corner post 50 mm 50 2 0,30
A 335 G (1) Axiom Profiles corner post 100 mm 100 2 0,50
A 336 G (1) Axiom Profiles corner post 150 mm 150 2 0,70
A 337 G (1) Axiom Profiles corner post 200 mm 200 2 0,90
A 345 G (1) Axiom Vector corner post 112 mm 112 2 0,60
A 340 G Axiom universal corner clip 100 2,10
A 338 G Axiom universal splice plate 100 2,10
A 339 G Axiom universal T bar connector clip 100 2,10
A 344 G Axiom universal hanging clip 100 2,10
50
100
150
19
19
19
19
200
112
Des
ign
Opt
ions
(1) Also available in colour RAL 9010 (WR)
Available in 5 heights with a plasterboard trim section, Axiom Profiles are compatible with 24 mm and 15 mm grid systems including designer grid.
A 344 G
A 339 G
A 340 G
A 344 G
A 334 GA 335 GA 336 GA 337 G A 345 G
A 338 G
25
System Drawing
Des
ign
Opt
ions
(1) Also available in colour RAL 9010 (WR)
AXIOM PROFILES
≤ 200
100
A
26 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
Des
ign
Opt
ions AXIOM C CANOPY
55 14 11 G Axiom Vector MicroLook Tegular Profile
C 3000 G Primary C channel
A WDN 21 H T bar hanger
Cut to size Main Runner 600 mm XL2 Cross Tees
A 345 G Axiom Vector MicroLook Tegular Profile corner post
A 348 G Channel bracket
CA 97 G Clamp for C channel
A 347 G 24 mm XL2 connector clip
A 346 G 15 mm XL2 connector clip
A 339 H Axiom universal T bar connector clip for cut tees with screws
Item Nr. Description
Axiom C Canopy Components
Axiom C Canopy Kits*
Module Grid system 15 mm XL2 Grid system 24 mm XL2
Item Nr. Item Nr.
1200 x 1200 mm AX 22 G15 AX 22 G24
1800 x 1200 mm AX 32 G15 AX 32 G24
1800 x 1800 mm AX 33 G15 AX 33 G24
2400 x 1200 mm AX 42 G15 AX 42 G24
2400 x 1800 mm AX 43 G15 AX 43 G24
2400 x 2400 mm AX 44 G15 AX 44 G24
3000 x 1200 mm AX 52 G15 AX 52 G24
3000 x 1800 mm AX 53 G15 AX 53 G24
3000 x 2400 mm AX 54 G15 AX 54 G24
3000 x 3000 mm AX 55 G15 AX 55 G24
*Ceiling tiles are NOT included in the kit.
1.2m
1.8m
2.4m
3.0m
2.4m 1.8m 1.2m3.0m
4 tiles 6 tiles8 tiles10 tiles
15 tiles 12 tiles 9 tiles
20 tiles 16 tiles
25 tiles
112 mm112 mm
Tegular / MicroLookVector
R E C O M M E N DAT I O N S
Axiom C Canopy should always be installed in accordance with allapplicable building codes and regulations.
• Axiom C Canopy should only be installed on a horizontal plane. They are not approved for exterior installations.
• Axiom C Canopy should always be installed by a minimum of 2 people.
• Read the installation instructions included in the carton carefully before starting the installation.
• Make sure the installation is clean and safe.
• Any additional weights (such as luminaires...) must be independently suspended from the soffit.
• Aircraft cables are included as a standard in the kit but if you require more lateral restraint, we would recommend the use of 6 mm threaded rod or provide diagonal bracing.
!
All measurements in millimetres. All sizes are nominal.
Axiom C Canopy is a perimeter trim system designed to create “ceiling clouds” in conjunction with full size tiles. Made from standard ceiling panels and ready to assemble Axiom components, Axiom C Canopy will define and individualise any space.
27
Des
ign
Opt
ionsAXIOM C CANOPY
System Drawing
6 Aircraft cables & Grippleconnectors
4 Cornerposts
4 Axiom profiles cut to size
3 C channels cut to size
2 Main Runners cut to size(24 mm or 15 mm)
12 Cross Tees 600 mm XL2
(24 mm or 15 mm)
6 T bar hangers
6 Channel brackets
4 Universal T barconnector clips
8 XL2
connector clips
6 Universal T barconnector clips
OPTION 36 mm Threaded rod*
* not included in the kit
OPTION 2Quick hanger*
OPTION 1Aircraft cable & Gripple connectors
The 1800 mm x 3000 mm module is used as an example only.An installation instruction guide is available. Please contact Armstrong Technical Sales for further details.
28 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
Axiom KE Canopy Components
Axiom KE Canopy Kits*
Item Nr. Description
CS 57 42 06 G Axiom KE Profile
C 3000 G Primary C channel
A WDN 21 H T bar hanger
Cut to size Main Runner 600mm XL2 Cross Tees
CS 57 G Mitre corner piece
A 361 G Mitre corner splice connector
A 348 G Channel bracket
CA 97 G Clamp for C channel
A 347 G 24 mm XL2 connector clip
A 346 G 15 mm XL2 connector clip
A 339 H Axiom universal T bar connector clip for cut tees with screws
A 338 G Axiom universal splice plate
Module Grid system 15 mm XL2 Grid system 24 mm XL2
Item Nr. Item Nr.
1200 x 1200 mm CS AK 22 G15 CS AK 22 G24
1800 x 1200 mm CS AK 32 G15 CS AK 32 G24
1800 x 1800 mm CS AK 33 G15 CS AK 33 G24
2400 x 1200 mm CS AK 42 G15 CS AK 42 G24
2400 x 1800 mm CS AK 43 G15 CS AK 43 G24
2400 x 2400 mm CS AK 44 G15 CS AK 44 G24
3000 x 1200 mm CS AK 52 G15 CS AK 52 G24
3000 x 1800 mm CS AK 53 G15 CS AK 53 G24
3000 x 2400 mm CS AK 54 G15 CS AK 54 G24
3000 x 3000 mm CS AK 55 G15 CS AK 55 G24
*Ceiling tiles are NOT included in the kit.
1.2m
1.8m
2.4m
3.0m
2.4m 1.8m 1.2m3.0m
4 tiles 6 tiles8 tiles10 tiles
15 tiles 12 tiles 9 tiles
20 tiles 16 tiles
25 tiles
AXIOM KE CANOPY
135 mm
106 mm
135 mm
106 mm
Vector
RECOMMENDATIONS
Axiom KE Canopies should always be installed in accordancewith all applicable building codes and regulations.
• Axiom KE Canopies should only be installed on a horizontal plane. They are not approved for exterior installations.
• Axiom KE Canopies should always be installed by a minimum of 2 people.
• Read the installation instructions included in the carton carefully before starting the installation.
• Make sure the installation is clean and safe.
• Any additional weights (such as luminaires...) must be independently suspended from the soffit.
• Aircraft cables are included as a standard in the kit but if you require more lateral restraint, we would recommend the use of 6 mm threaded rod or provide diagonal bracing.
!
Des
ign
Opt
ions
Tegular / MicroLook
All measurements in millimetres. All sizes are nominal.
Axiom KE Canopy is an aesthetic perimeter trim system designed to create “ceiling clouds” in conjunction with full size tiles. Made from standard ceiling panels and ready to assemble Axiom components, Axiom KE Canopy is a quick refurbishment solution, ideal for acoustically challenged or open plenum spaces.
29
System Drawing
4 Universal T barconnector clips
6 Aircraft cables &Gripple connectors
6 Universal T barconnector clips
8 Corner spliceconnectors
4 Mitre Corners
4 Axiom profilescut to size
3 C channelscut to size2 Main Runners cut to size
(24 mm or 15 mm)
12 Cross Tees 600 mm XL2
(24 mm or 15 mm)
6 T bar hangers
6 Channel brackets
16 Axiomuniversal spliceplates
8 XL2
connector clips
AXIOM KE CANOPY
The 1800 mm x 3000 mm module is used as an example only.An installation instruction guide is available. Please contact Armstrong Technical Sales for further details.
Des
ign
Opt
ions
OPTION 36 mm Threaded rod*
* not included in the kit
OPTION 2Quick hanger*
OPTION 1Aircraft cable & Gripple connectors
RECOMMENDATIONSAxiom Circle & Curved Canopies should always be installed inaccordance with all applicable building codes and regulations.• Axiom Circle & Curved Canopies should only be installed on a horizontal plane. They are not approved for exterior installations.• Axiom Circle & Curved Canopies should always be installed by a minimum of 2 people.• Read the installation instructions included in the carton carefully before starting the installation.• Make sure the installation is clean and safe.• Any additional weights (such as luminaires...) must be independently suspended from the soffit.• Aircraft cables are included as a standard in the kit but if you require more lateral restraint, we would recommend the use of 6 mm threaded rod or provide diagonal bracing.
30 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
AXIOM CIRCLE & CURVEDD
esig
n O
ptio
ns
Axiom Circle & Curves Components
Axiom Circle & Curved Kits*
Item Nr. Description
Module Grid system 15 mm XL2 Grid system 24 mm XL2
Item Nr. Item Nr.
Circle 1800 CS ACI 33 G15 CS ACI 33 G24
Circle 2400 CS ACI 44 G15 CS ACI 44 G24
Curved 2400 x 1800 CS ACU 43 G15 CS ACU 43 G24
Curved 2400 x 2400 CS ACU 44 G15 CS ACU 44 G24
Curved 3000 x 1800 CS ACU 53 G15 CS ACU 53 G24
Curved 3000 x 2400 CS ACU 54 G15 CS ACU 54 G24
Curved 3000 x 3000 CS ACU 55 G15 CS ACU 55 G24
!
The Axiom Circle & Curved Canopies are an aesthetic perimeter trim system designed to create “ceiling clouds” inconjunction with full size tiles. Made from standard ceiling panels and ready to assemble Axiom components, Curved and Circle Canopies allow specifiers to play with different planes and levels as well as conceal service elements.
62 42 06 G Axiom Circle and Curved Profile
C3000 G Primary C Channel
30 40 33 A Prelude Peakform Main Runner T15 or
31 40 32 A Prelude Peakform Main Runner T24
30 20 33 B Prelude XL2 Cross Tee 600 mm T15 or
31 20 21 A Prelude XL2 Cross Tee 600 mm T24
AWDN 21 H T bar hanger
A 361 G Splice connector
A 339 H Axiom universal T bar connector clip for cut tees with screws
A 156 G Perimeter fill-in for 15 mm grid
A 246 G Perimeter fill-in for 24 mm grid
A 348 G Channel bracket
CA 97 G Clamp for C Channel
1.8m Ø Canopy
2.4m Ø Canopy 2.4m x 2.4m Canopy 2.4m x 3m Canopy
3m x 3m Canopy
1.8m x 3m Canopy1.8m x 2.4m Canopy
All measurements in millimetres. All sizes are nominal.
*Ceiling tiles are NOT included in the kit.
Tegular / MicroLook
31
AXIOM CIRCLE & CURVED
Des
ign
Opt
ions
System Drawing
OPTION 36 mm Threaded rod*
OPTION 2Quick hanger*
10 Universal T barconnector clips
6 Universal T barconnector clips
6 Aircraft cables & Gripple connectors
Splice connector
Axiom Profiles cut to size
3 C Channels cut to size12 Cross Tees600 mm XL2
(24 mm or 15 mm)
2 Main Runners cut to size(24 mm or 15 mm)
6 T bar hangers
6 Channel brackets
* not included in the kit
The 1.8 x 2.4 m module is used as an example only.An installation instruction guide is available.Please contact Armstrong Technical Sales for further details.
OPTION 1Aircraft cable & Gripple connectors
32 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
SILHOUETTE 15 XL2
with 6 mm reveal80 40 42 G(1) 3600 44 20 72,00 24,50 3680 39 43 G(1) 3125 44 20 62,50 25,40 2580 44 42 G(1) 2700 44 20 54,00 18,40 30
with 3 mm reveal81 40 42 WRG(2) 3600 44 20 72,00 24,50 36
Item Nr. Dimensions Content / Carton Weight / Carton Cartons / Pallet length (mm) height (mm) pcs lm kg
with 6 mm reveal80 30 42 G(1) 1200 44 60 72,00 24,50 3580 31 43 G(1) 1250 44 60 75,00 23,80 3580 33 42 G(1) 1350 44 30 40,50 13,80 5080 32 42 G(1) 1000 44 60 60,00 20,40 24
80 20 42 G(1) 600 44 60 36,00 12,70 7080 21 43 G(1) 625 44 30 37,50 16,00 7080 23 42 G(1) 675 44 60 40,50 14,30 7080 22 42 G(1) 500 44 60 30,00 10,60 7080 24 42 G(1) 300 44 120 36,00 34,00 70
with 3 mm reveal81 30 42 WRG(2) 1200 44 60 72,00 24,50 35
81 20 42 WRG(2) 600 44 60 36,00 12,70 70
All products standard in Global White unless indicated by index (2). Other standard colours available for itemnumbers with index (1). See details below.(1) Silhouette with 6 mm reveal is available in white, black (BK) or white with black reveal (BI).(2) WR = White RAL 9010 (WR)
675 / 625 / 600 / 500 / 300
1350 675 675 1250 625 6251200 600 6001000 500 500
Main Runners Silhouette 15
Cross Tee Silhouette 15 XL2
Cross Tee Silhouette 15 XL2
3600 300 600 3 x 600 600 3003500 250 500 4 x 500 500 2503125 312,5 625 2 x 625 625 312,52700 337,5 675 675 675 337,5
Length
Length
All measurements in millimetres. All sizes are nominal.
Main Runners Silhouette 15 (by-pass connection)
Peakform Cross Tees Silhouette 15 XL2 (stab system)
Section Drawings
Exposed 15 mm grid system (nominal).Silhouette 15 XL2 is a suspension system designed to create a crisp, clean look in conjunction with MicroLooktiles to provide an enhanced aesthetic.
Des
ign
Opt
ions
33
SILHOUETTE 15 XL2
Silhouette 15 XL2
Grid Load Capacity
- Pre-mitred intersections- Choice of either 6 or 3 mm reveal dimension- Silhouette 15 XL2 with 3 mm reveal is supplied as standard in RAL 9010 white to compliment Armstrong metal tiles
8
424
MCC4 GMitre closure clip for 6 mm reveal
View of mitred intersection from beneath
Section
Section
Axiom Profiles(50, 100, 112, 150 and 200 mm heights available)
Silhouette 15 XL2 system
A 339 GAxiom universal T bar connector clip
Cross Tee trimmed to wall angle
Cross Tee trimmed to shadowline T 1508 HB at perimeter
Perimeter Solutions
Silhouette 15 XL2 System The following table gives the maximum permitted hanger distance (mm) along the Silhouette Main Runner (80 40 42 G) for the tile weights and Main Runner spacings noted.
Tile weight
2,5 kg/m2
3,0 kg/m2
3,5 kg/m2
4,0 kg/m2
5,0 kg/m2
5,5 kg/m2
6,0 kg/m2
7,0 kg/m2
8,5 kg/m2
10,5 kg/m2
13,0 kg/m2
Main Runner spacing 1200 mm 1200 mm XL2 Cross Tee
80 30 42 G
1800
1700
1650
1600
1500
1450
1400
1300
1200
1100
950
Main Runner spacing 600 mm 600 mm XL2 Cross Tee
80 20 42 G
2100
2100
2050
2000
1900
1850
1800
1700
1600
1550
1350
1) Values in the above table conform to Class 1 as defined in EN 13964:2004+A1:2006 table 6. For other classes /deflection limits please contact your local Armstrong Technical Sales team.
2) Values are determined from laboratory tests methods in accordance with EN 13964:2004+A1:2006 clause 5.
3) Values are applicable for 600 x 600 mm tiles assuming that the maximum deflection of the grid is L/500 but not greater than 4 mm (L = span).
4) No other applied loads such as luminaires, air diffusers, smoke detectors, sprinklers, hanging signs etc. are permitted.
5) No overlays such as mineral wool or fibre glass quilts, as may be required for enhanced acoustic, fire or thermal performance, are permitted unless their full weight is established and included, together with the weight of the tile, within the appropriate weight groups.
6) For grid loading data calculated to different criteria than Class 1 to EN13964:2004+A1:2006, see the grid loading technical section on pages 20 - 21.
Hanger spacing
Availability of products may vary according to location.Please contact Armstrong Technical Sales for further details.
Des
ign
Opt
ions
34 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
Des
ign
Opt
ions INTERLUDE 15 XL2
TZ 61 40 42 3600 44 20 72,00 23,60 36
Item Nr. Dimensions Content / Carton Weight / Carton Cartons / Pallet length (mm) height (mm) pcs lm kg
Main Runner Interlude 15 (by-pass connection)
Cross Tees Interlude 15 XL2 (stab system)
Section Drawings
Cross Tees slotted61 30 42 G 1200 44 60 72,00 30,30 42
Cross Tees unslotted61 20 42 G 600 44 60 36,00 15,00 84
TZ 61 24 42 300 44 120 36,00 15,00 84
600 / 300
1200 600 600
3600 75 150 22 x 150 75
Main Runner Interlude 15
Cross Tee Interlude 15 XL2
Cross Tee Interlude 15 XL2
Length
Length
Product available as standard in Global White.All measurements in millimetres. All sizes are nominal.
Exposed 15 mm grid system (nominal).Interlude 15 XL2 is a suspension system developed for creative ceiling solutions, and quick and easy installation.
35
Des
ign
Opt
ionsINTERLUDE 15 XL2
Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details.
Interlude 15 XL2
Interlude 15 XL2 can be easily field cutwith snips in 3 simple steps:
- The stepped flange profile provides a unique double reveal visual- Unmitred intersections allow for Cross Tee installation at any
Main Runner slot position
Grid Load Capacities
Interlude 15 XL2 systemThe following table gives the maximum permitted hanger distance (mm) along the Interlude Main Runner (TZ 61 40 42) for the tile weights and Main Runner spacings noted.
Tile weight
2,5 kg/m2
3,0 kg/m2
3,5 kg/m2
4,0 kg/m2
5,0 kg/m2
5,5 kg/m2
6,0 kg/m2
7,0 kg/m2
8,5 kg/m2
10,5 kg/m2
13,0 kg/m2
Main Runner spacing 1200 mm 1200 mm XL2 Cross Tee
61 30 42 G
1950
1850
1750
1750
1650
1600
1550
1450
1350
1250
1100
Cross Tee trimmed to wall angle
Section
Section
Perimeter Solutions
Partition Head Fixing
Cross Tee trimmed to shadowlineT 1508 HB
1. Cut down through bulb and web
2. Snip flanges
3. Bend away from bulb to snap off centre rail
UPC AG Universal partition clipattaches to grid to provide fixingfor partition head track: reversible for15 mm or 24 mm grid systems
Main Runner spacing 600 mm 600 mm XL2 Cross Tee
61 20 42 G
2100
2100
2100
2100
2050
2000
1950
1850
1750
1650
1550
Hanger spacing1) Values in the above table conform to Class 1 as defined in EN 13964:2004+A1:2006 table 6. For other classes /deflection limits please contact your local Armstrong Technical Sales team.
2) Values are determined from laboratory tests methods in accordance with EN 13964:2004+A1:2006 clause 5.
3) Values are applicable for 600 x 600 mm tiles assuming that the maximum deflection of the grid is L/500 but not greater than 4 mm (L = span).
4) No other applied loads such as luminaires, air diffusers, smoke detectors, sprinklers, hanging signs etc. are permitted.
5) No overlays such as mineral wool or fibre glass quilts, as may be required for enhanced acoustic, fire or thermal performance, are permitted unless their full weight is established and included, together with the weight of the tile, within the appropriate weight groups.
6) For grid loading data calculated to different criteria than Class 1 to EN13964:2004+A1:2006, see the grid loading technical section on pages 20 - 21.
36 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
Des
ign
Opt
ions MICROLINE 15 XL2
CS 25 42 92 WR 600* 3000 49 20 60 23,00 32*slotted at 600 mm
CS 25 42 92 WR 750* 3000 49 20 60 23,00 32
*slotted at 750 mm
Item Nr. Dimensions Content / Carton Weight / Carton Cartons / Pallet length (mm) height (mm) pcs lm kg
Main Runners Microline 15 (bulb-to-bulb connection)
Cross Tees Microline 15 XL2 (stab system)
Section Drawings
Cross Tee slotted (at 600 mm)
CS 25 30 42 WR 1200 44 60 72 26,00 72
Cross Tees unslotted
CS 25 20 42 WR 600 44 60 36 13,00 144
CS 25 16 42 WR 750 44 60 45 16,00 144
Main Runners Microline 15
Cross Tee Microline 15 XL2
Cross Tee Microline 15 XL2
All dimensions are nominal (millimeters).
Cross tee alignment is achieved by locating the tees to the right-hand side of the adjoining section.
Steel based grid with aluminium extrusion. The exposed sleeve provides a clean and crisp visual plus a practical fluted reveal for flexibility in partition fixing and relocation.
3000 300 3 x 600 600 300
3000 375 2 x 750 750 375
1200 600600
600/750
15 mm
49 mm
15 mm
44 mm
15 mm
44 mm
37
Des
ign
Opt
ionsMICROLINE 15 XL2
Key Attributes Physical Data
Perimeter Options*
• Peakform Patented universal Main Runner and Cross Tee design increase strength and stability for improved performance and makes the grid easier to cut. The aluminium sleeves must be cut aside using a hand saw.
• For metal tiles with MicroLook 8mm edge
• Fluted reveal for M6 bolt
• Material Chassis : Double web galvanised steel Sleeve : Extruded aluminium
• Surface finish of the sleeve Baked polyester paint
• Product Family Designer grids
• Main Runner / Cross Tee Interface Pre-mitred intersections
• End Detail Main Runner : bulb-to-bulb connection Cross Tees : staked-on stab clip
• Colour Available in white (RAL9010) only
Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details.
Grid Load Capacities
40
20
T 2040 H WR APerimeter channel and perimeter wedge for cut modules
C 1803 H
T 2040 H WR A Perimeter channel RAL 9010 3050 20 61,00 18,10
C 1803 H Perimeter wedge 200 100 - 5,00
*Made up of steel
Item Nr. Description Dimensions Content / Carton Weight / Carton height (mm) pcs lm kg
Microline XL2 System The following table gives the maximum permitted hanger distance (mm) along the Main Runner
Tile weight
2,5 kg/m2
3,0 kg/m2
3,5 kg/m2
4,0 kg/m2
4,5 kg/m2
5,0 kg/m2
5,5 kg/m2
6,0 kg/m2
6,5 kg/m2
7,0 kg/m2
8,0 kg/m2
9,0 kg/m2
10,0 kg/m2
14,0 kg/m2
1200 mmXL2 Cross Tee CS 25 30 42
1950
1950
1850
1750
1650
1600
1500
1450
1400
1350
1250
1200
1150
-
750 mmXL2 Cross Tee CS 25 16 42
2200
2200
2200
2200
2050
1950
1900
1800
1750
1700
1600
1500
1400
1200
600 mmXL2 Cross Tee CS 25 20 42
2350
2350
2350
2350
2300
2200
2100
2000
1950
1850
1750
1650
1600
1350
Hanger spacing 1) Values in the above table conform to Class 1 as defined in EN 13964:2004+A1:2006 table 6. For other classes /deflection limits please contact your local Armstrong Technical Sales team.
2) Values are determined from laboratory tests methods in accordance with EN 13964:2004+A1:2006 clause 5.
3) Values are applicable for 600 x 600 mm tiles assuming that the maximum deflection of the grid is L/500 but not greater than 4 mm (L = span).
4) No other applied loads such as luminaires, air diffusers, smoke detectors, sprinklers, hanging signs etc. are permitted.
5) No overlays such as mineral wool or fibre glass quilts, as may be required for enhanced acoustic, fire or thermal performance, are permitted unless their full weight is established and included, together with the weight of the tile, within the appropriate weight groups.
6) For grid loading data calculated to different criteria than Class 1 to EN13964:2004+A1:2006, see the grid loading technical section on pages 20 - 21.
38 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
Gen
eral
App
licat
ions PRELUDE 15
30 40 33 A(1) 3600 43 20 72,00 22,50 3230 41 33 A(1) 3750 43 20 75,00 23,20 3230 43 33 A 3375 43 20 67,50 22,50 32
Item Nr. Dimensions Content / Carton Weight / Carton Cartons / Pallet length (mm) height (mm) pcs lm kg
Universal Main Runners Prelude 15 Peakform and Superlock Clip (bulb-to-bulb connection)
Cross Tees Prelude 15 XL2 (stab system, override)
Cross Tees Prelude 15 TL (hook system, butt cut)
Section Drawings
Cross Tees slotted30 30 33 B(1) 1200 38 60 72,00 20,70 7230 31 33 A 1250 38 60 75,00 21,50 7230 32 33 (2) 1000 38 60 60,00 17,20 72
Cross Tees unslotted30 20 33 B(1) 600 38 60 36,00 10,30 14430 21 33 A 625 38 60 37,50 10,70 14430 22 33 (2) 500 38 60 30,00 8,60 144
Cross Tees slotted10 34 33 B 1800 38 30 54,00 15,20 20 10 36 33 A 1500 38 30 45,00 14,00 20 10 33 33 1350 38 60 81,00 26,00 72 10 31 33 B(1) 1250 38 60 75,00 21,60 72 10 30 33 A(1) 1200 38 60 72,00 20,70 72
Cross Tees unslotted10 23 33 675 38 60 40,50 13,00 144 10 21 33 B(1) 625 38 60 37,50 10,70 144 10 20 33 A(1) 600 38 60 36,00 10,30 144 10 25 33 312,50 38 120 37,50 12,50 144 10 24 33 A 300 38 120 36,00 11,50 144 10 12 32 150 38 60 9,00 2,84 144
3750 78,125 156,25 21 x 156,25 156,25 78,125 3600 50 100 33 x 100 100 503375 337,5 675 2 x 675 675 337,5
1250 312,5 2 x 312,5 312,51200 300 2 x 300 3001000 250 2 x 250 250
625 / 600 / 500 675 / 625 / 600 / 312,5 / 300 /150
Length
Length
1800 300 4 x 300 3001500 300 3 x 300 3001350 337,5 2 x 337,5 337,51250 312,5 2 x 312,5 312,51200 300 2 x 300 300
Length
Universal Main Runners Prelude 15
Cross Tee Prelude 15 XL2
Cross Tee Prelude 15 XL2
Cross Tee Prelude 15 TL
Cross Tee Prelude 15 TL
All products standard in Global White. Other standard colours available for item numbers with index (1) or (2). See details below.
(1)Colours available : Carrara (CA), Platinum (PN), Black (BK), RAL 9006 (SG), Brass (BS), Chrome (CE), White RAL 9010 (WR).
(2) Also available in RAL 9010 (WR).Cross tee alignment is achieved by locating the tees to the right-hand side of the adjoining section.All measurements in millimetres. All sizes are nominal.
Exposed 15 mm grid system (nominal).
39
Gen
eral
App
licat
ionsPRELUDE 15
System Drawing (module 600 x 600 mm)
Standard lay-in installation of 15 mm exposed suspensionsystem for MicroLook tiles andspecific Board tiles.
*reduce to 450 if heavy tile /overlays are used or heavyservice fittings are locatednear the perimeter.
Grid Load Capacities
Prelude 15 System The following table gives the maximum permitted hanger distance (mm) along the Peakform Main Runner (30 40 33 A) for the tile weights andMain Runner spacings noted.
Tile weight
2,5 kg/m2
3,0 kg/m2
3,5 kg/m2
4,0 kg/m2
5,0 kg/m2
5,5 kg/m2
6,0 kg/m2
7,0 kg/m2
8,5 kg/m2
10,5 kg/m2
13,0 kg/m2
Main Runner spacing 1200 mm
1200 mm TLCross Tee
10 30 33 A
1900
1800
1750
1650
1550
1550
1500
1400
1300
1150
1050
Main Runner spacing 600 mm
600 mm TL Cross Tee
10 20 33 A
2100
2100
2100
2050
2000
1950
1900
1800
1700
1600
1500
Main Runner spacing 1200 mm
1200 mm XL2 Cross Tee
30 30 33 B
1900
1800
1750
1650
1550
1550
1500
1400
1300
1150
1050
Main Runner spacing 600 mm
600 mm XL2 Cross Tee
30 20 33 B
2100
2100
2100
2050
2000
1950
1900
1800
1700
1600
1500
1) Values in the above table conform to Class 1 as defined in EN 13964:2004+A1:2006 table 6. For other classes /deflection limits please contact your local Armstrong Technical Sales team.
2) Values are determined from laboratory tests methods in accordance with EN 13964:2004+A1:2006 clause 5.
3) Values are applicable for 600 x 600 mm tiles assuming that the maximum deflection of the grid is L/500 but not greater than 4 mm (L = span).
4) No other applied loads such as luminaires, air diffusers, smoke detectors, sprinklers, hanging signs etc. are permitted.
5) No overlays such as mineral wool or fibre glass quilts, as may be required for enhanced acoustic, fire or thermal performance, are permitted unless their full weight is established and included, together with the weight of the tile, within the appropriate weight groups.
6) For grid loading data calculated to different criteria than Class 1 to EN13964:2004+A1:2006, see the grid loading technical section on pages 20 - 21.
Tile Main Runner Hanger centres Main Runner Cross Tee Cross Tee Hanger Universal centres 1200 mm 600 mm retaining clip
600 x 600 mm 2,78 pcs
1200 x 600 mm 1,39 pcs
6 1 2 3 4 7
5 The chart is for general guidance only.
Quantities required per 1m2 (no waste included)
Perimeter trim approx. 0,70 lm/m2
1200 mm
600 mm
1200 mm
600 mm
1200 mm
1200 mm
1200 mm
1200 mm
0,84 lm
1,67 lm
0,84 lm
1,67 lm
1,67 lm
-
1,67 lm
-
0,84 lm
1,67 lm
-
0,84 lm
0,70 pcs
1,40 pcs
0,70 pcs
1,40 pcs
5,56 pcs
5,56 pcs
5,56 pcs
5,56 pcs
Hanger spacing
40 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
Gen
eral
App
licat
ions
31 40 32 A(1) 3600 43 20 72,00 21,00 3031 41 33 B(1) 3750 43 20 75,00 21,90 3031 43 33 A 3375 43 20 67,50 20,00 3031 42 32 3000 43 20 60,00 17,50 30
Item Nr. Dimensions Content / Carton Weight / Carton Cartons / Pallet length (mm) height (mm) pcs lm kg
Universal Main Runners Prelude 24 Peakform and Superlock Clip (bulb-to-bulb connection)
Cross Tees Prelude 24 XL2 (stab system, override)
Section Drawings
Cross Tee Prelude 24 XL2
31 33 31 1350 38 60 81,00 17,20 2031 31 51 B(1) 1250 38 60 75,00 18,90 7231 30 51 B(1) 1200 38 60 72,00 18,20 7231 32 31(2) 1000 38 60 60,00 15,10 42
31 34 31 A 1800 38 30 54,00 17,00 20
31 16 32 750 38 60 45,00 14,70 7231 25 32 312,50 38 60 18,75 4,60 14431 24 32 300 38 60 18,00 4,60 14431 23 21 675 30 60 40,50 7,70 14431 21 23 A(1) 625 30 60 37,50 8,60 14431 20 21 A(1) 600 30 60 36,00 8,20 14431 22 21(2) 500 30 60 30,00 6,80 84
3750 78,125 156,25 21 x 156,25 156,25 78,1253600 50 100 33 x 100 100 503375 337,5 675 2 x 675 675 337,53000 50 100 27 x 100 100 50
1800 300 4 x 300 3001350 337,5 2 x 337,5 337,51250 312,5 2 x 312,5 312,51200 300 2 x 300 3001000 250 2 x 250 250
750 / 675 / 625 / 600 / 500 / 312,50 / 300
Cross Tee Prelude 24 XL2
Length
Length
Universal Main Runners Prelude 24
All products standard in Global White. Other standard colours available for item numbers with index (1) or (2). See details below.(1) Colours available : Carrara (CA), Platinum (PN), Black (BK), RAL 9006 (SG), Brass (BS), Chrome (CE), White RAL 9010 (WR).(2) Also available in RAL 9010 (WR).Cross tee alignment is achieved by locating the tees to the right-hand side of the adjoining section.All measurements in millimetres. All sizes are nominal.
PRELUDE 24 XL2
Cross Tees slotted
Cross Tees unslotted
Exposed 24 mm grid system (nominal).
41
Gen
eral
App
licat
ions
Tile Main Runner Hangers Main Runner Cross Tee Cross Tee Hanger Universal centres centres 1200 mm 600 mm retaining clip
1200 x 600 mm 1,39 pcs
600 x 600 mm 2,78 pcs
PRELUDE 24 XL2
System Drawing (module 1200 x 600 mm)
*
6 1 2 3 4 7
5
Standard lay-in installation of 24 mm exposed suspension systemusing Board, Tegular or Vector tiles.
Grid Load Capacities
Prelude 24 XL2 System The following table gives the maximum permitted hanger distance (mm) along the Peakform Main Runner (31 40 32 A) for the tile weights and Main Runner spacings noted.
Tile weight
2,5 kg/m2
3,0 kg/m2
3,5 kg/m2
4,0 kg/m2
5,0 kg/m2
5,5 kg/m2
6,0 kg/m2
7,0 kg/m2
8,5 kg/m2
10,5 kg/m2
13,0 kg/m2
Main Runner spacing 1800 mm 1800 mm XL2 Cross Tee
31 34 31 A
1650
1600
1500
1450
1350
1350
1250
-
-
-
-
Main Runner spacing 1200 mm
1200 mm XL2 Cross Tee
31 30 51 B
1900
1800
1750
1700
1600
1550
1500
1450
1300
1200
1050
Main Runner spacing 600 mm
60 mm XL2 Cross Tee
31 20 21 A
2100
2100
2100
2100
2000
1950
1900
1800
1700
1600
1500
Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details.
The chart is for general guidance only.
Quantities required per 1m2 (no waste included)
Perimeter trim approx. 0,70 lm/m2
1200 mm
600 mm
1200 mm
600 mm
1200 mm
1200 mm
1200 mm
1200 mm
0,84 lm
1,67 lm
0,84 lm
1,67 lm
1,67 lm
-
1,67 lm
-
-
0,84 lm
0,84 lm
1,67 lm
0,70 pcs
1,40 pcs
0,70 pcs
1,40 pcs
5,56 pcs
5,56 pcs
5,56 pcs
5,56 pcs
Hanger spacing
*reduce to 450 if heavy tile /overlays are used or heavyservice fittings are locatednear the perimeter.
*
1) Values in the above table conform to Class 1 as defined in EN 13964:2004+A1:2006 table 6. For other classes /deflection limits please contact your local Armstrong Technical Sales team.
2) Values are determined from laboratory tests methods in accordance with EN 13964:2004+A1:2006 clause 5.
3) Values are applicable for 600 x 600 mm tiles assuming that the maximum deflection of the grid is L/500 but not greater than 4 mm (L = span).
4) No other applied loads such as luminaires, air diffusers, smoke detectors, sprinklers, hanging signs etc. are permitted.
5) No overlays such as mineral wool or fibre glass quilts, as may be required for enhanced acoustic, fire or thermal performance, are permitted unless their full weight is established and included, together with the weight of the tile, within the appropriate weight groups.
6) For grid loading data calculated to different criteria than Class 1 to EN13964:2004+A1:2006, see the grid loading technical section on pages 20 - 21.
42 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
PRELUDE 24 TLX
Item Nr. Dimensions Content / Carton Weight / Carton Cartons / Pallet Length (mm) Height (mm) pcs lm kg
Cross Tees Prelude 24 TLX (Hook system, butt cut)
Universal Main Runners Prelude 24 Peakform and Superlock Clip (bulb-to-bulb connection)
900 / 750 / 675 / 625 / 600 / 500
Cross Tee Prelude 24 TLX
Section Drawings
31 40 32 A(1) 3600 43 20 72,00 21,00 3031 41 33 B(1) 3750 43 20 75,00 21,90 3031 43 33 A 3375 43 20 67,50 20,00 3031 42 32 3000 43 20 60,00 17,50 30
Cross Tees slotted13 31 31(1) 1250 38 60 75,00 18,90 72 13 30 31(1) (2) 1200 38 60 72,00 18,10 72 13 60 31 600 38 60 36,00 9,10 144
13 10 32 1875 38 30 56,20 17,80 20 13 34 32 1800 38 30 54,00 17,10 20 13 50 32 1724 38 30 51,70 16,50 20 13 36 32 1500 38 30 45,00 14,50 20 13 33 31 1350 38 60 81,00 19,60 2013 32 32 1000 38 60 60,00 19,40 72
Cross Tees unslotted13 18 31 900 38 60 54,00 13,60 72 13 16 31 750 38 60 45,00 11,40 7213 21 31(1) 625 38 60 37,50 9,50 144 13 20 31(1) (2) 600 38 60 36,00 9,10 144
13 23 31 675 38 60 40,50 8,70 144 13 22 32 500 38 60 30,00 9,70 80
3750 78,125 156,25 21 x 156,25 156,25 78,1253600 50 100 33 x 100 100 503375 337,5 675 2 x 675 675 337,53000 50 100 27 x 100 100 50
Length
Universal Main Runners Prelude 24
Cross Tee Prelude 24 TLX
1875 312,5 4 x 312,5 312,51800 300 4 x 300 3001724 262 4 x 300 2621500 150 350 / 2 x 250 / 350 1501350 337,5 2 x 337,5 337,51250 312,5 2 x 312,5 312,51200 300 2 x 300 3001000 250 2 x 250 250
Length
All products standard in Global White. Other standard colours available for item numbers with index (1) or (2). See details below.(1) Colours available : Carrara (CA), Platinum (PN), Black (BK), RAL 9006 (SG), Brass (BS), Chrome (CE) and White RAL 9010 (WR). (2) Also available in Black (NG), Brown (MR) and Beige (BJ).Cross tee alignment is achieved by locating the tees to the right-hand side of the adjoining section.
Exposed 24 mm grid system (nominal).
Gen
eral
App
licat
ions
43
Gen
eral
App
licat
ions
Tile Main Runner Hanger Main Runner Cross Tee Cross Tee Hanger Universal centres centres 1200 mm 600 mm Retaining Clip
1200 x 600 mm 1,39 pcs
600 x 600 mm 2,78 pcs
System Drawing (module 1200 x 600 mm)
6 1 2 3 4 7
5
Standard lay-in installation of 24 mm exposed suspension system using Board, Tegular orVector edge tiles.
The chart is for general guidance only.
Quantities required per 1m2 (no waste included)
Perimeter Trim approx. 0,70 lm/m2
1200 mm
600 mm
1200 mm
600 mm
1200 mm
1200 mm
1200 mm
1200 mm
0,84 lm
1,67 lm
0,84 lm
1,67 lm
1,67 lm
-
1,67 lm
-
-
0,84 lm
0,84 lm
1,67 lm
0,70 pcs
1,40 pcs
0,70 pcs
1,40 pcs
5,56 pcs
5,56 pcs
5,56 pcs
5,56 pcs
PRELUDE 24 TLX
Grid Load Capacities
Prelude 24 TLX System The following table gives the maximum permitted hanger distance (mm) along the Peakform Main Runner (31 40 32 A) for the tile weights and Main Runner spacings noted.
Tile weight
2,5 kg/m2
3,0 kg/m2
3,5 kg/m2
4,0 kg/m2
5,0 kg/m2
5,5 kg/m2
6,0 kg/m2
7,0 kg/m2
8,5 kg/m2
10,5 kg/m2
13,0 kg/m2
Main Runner spacing 1800 mm 1800 mm TLXCross Tee
13 34 32
1650
1600
1500
1450
1350
1350
1250
-
-
-
-
Main Runner spacing 1200 mm 1200 mm TLXCross Tee
13 30 31
1900
1800
1750
1700
1600
1550
1500
1450
1300
1200
1050
Main Runner spacing 600 mm 600 mm TLX Cross Tee
13 20 31
2100
2100
2100
2100
2000
1950
1900
1800
1700
1600
1500
1) Values in the above table conform to Class 1 as defined in EN 13964:2004+A1:2006 table 6. For other classes /deflection limits please contact your local Armstrong Technical Sales team.
2) Values are determined from laboratory tests methods in accordance with EN 13964:2004+A1:2006 clause 5.
3) Values are applicable for 600 x 600 mm tiles assuming that the maximum deflection of the grid is L/500 but not greater than 4 mm (L = span).
4) No other applied loads such as luminaires, air diffusers, smoke detectors, sprinklers, hanging signs etc. are permitted.
5) No overlays such as mineral wool or fibre glass quilts, as may be required for enhanced acoustic, fire or thermal performance, are permitted unless their full weight is established and included, together with the weight of the tile, within the appropriate weight groups.
6) For grid loading data calculated to different criteria than Class 1 to EN13964:2004+A1:2006, see the grid loading technical section on pages 20 - 21.
Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details.
Hanger spacing
*reduce to 450 if heavy tile / overlaysare used or heavy service fittings arelocated near the perimeter.
*
44 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
PRELUDE SIXTY2
Gen
eral
App
licat
ions
Universal Main Runner Prelude Sixty2 Double Peakform with Superlock Clip (bulb to bulb connection)
3750 156,25 11 x 312,5 156,253600 150 11 x 300 1503375 168,75 9 x 337,5 168,75
Length
Universal Main Runner Prelude Sixty2
40 40 93 G(1) 3600 62 12 43,20 21,90 36
40 41 93 G(1) 3750 62 12 45,00 22,80 36
40 43 93 G(1) 3375 62 12 40,50 20,60 36
Cross Tees Prelude 24 TLX (hook system, butt cut)
Cross Tees slotted13 31 31(1) 1250 38 60 75,00 18,90 7213 30 31(1) (2) 1200 38 60 72,00 18,10 7213 60 31 600 38 60 36,00 9,10 144
13 10 32 1875 38 30 56,20 17,80 20 13 34 32 1800 38 30 54,00 17,10 20 13 50 32 1724 38 30 51,70 16,50 20 13 36 32 1500 38 30 45,00 14,50 2013 33 31 1350 38 60 81,00 19,60 20 13 32 32 1000 38 60 60,00 19,40 72
Cross Tees unslotted13 18 31 900 38 60 54,00 13,60 7213 16 31 750 38 60 45,00 11,40 7213 21 31(1) 625 38 60 37,50 9,50 144 13 20 31(1) (2) 600 38 60 36,00 9,10 144
13 23 31 675 38 60 40,50 8,70 144 13 22 32 500 38 60 30,00 9,70 80
Cross Tees Prelude 24 XL2 (stab system, override)
Cross Tees slotted31 33 31 1350 38 60 81,00 17,20 2031 31 51 B(1) 1250 38 60 75,00 18,90 7231 30 51 B(1) 1200 38 60 72,00 18,20 7231 32 31(3) 1000 38 60 60,00 15,10 42
31 34 31 A 1800 38 30 54,00 17,00 20
Cross Tees unslotted31 16 32 750 38 60 45,00 14,70 72 31 25 32 312,50 38 60 18,75 4,60 14431 24 32 300 38 60 18,00 4,60 14431 23 21 675 30 60 40,50 7,70 14431 21 23 A(1) 625 30 60 37,50 8,60 144 31 20 21 A(1) 600 30 60 36,00 8,20 144 31 22 21(3) 500 30 60 30,00 6,80 84
Item Nr. Dimensions Content / Carton Weight / Carton Cartons / Pallet Length (mm) Height (mm) pcs lm kg
All products standard in Global White. Other standard colours available for item numbers with index (1) or (2). See details below.(1) Colours available : Carrara (CA), Platinum (PN), Black (BK), RAL 9006 (SG), Brass (BS), Chrome (CE), White RAL 9010 (WR).(2) Also available in Black (NG), Brown (MR), Beige (BJ).(3) Also available in RAL 9010 (WR).All measurements in millimetres. All sizes are nominal.
Exposed 24 mm grid system (nominal).Double Peakform Main Runner section requiring less suspension points and compatible with Prelude 24 XL2 and TLX Cross Tees. For corridor applications please see page 50 - 51.
45
PRELUDE SIXTY2
Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details.
Accessories
Item Nr. Description Dimensions Content/Carton Weight/Carton Length (mm) Height (mm) pcs kg
A 401 G Top Connector Clip accessory for - - - - Prelude Sixty2 (Included in the carton)
A WDN 23 G Double bent tee bar hanger 57 36 100 2,30
Tile Main Runner centres Main Runner Cross Tee 1800 mm Cross Tee 1200 mm Cross Tee 600 mm
System Drawing (module 1800 x 300 mm)
3 1 2 2 2
The chart is for general guidance only.
Quantities required per 1m2 (no waste included)
1800 x 300 mm
600 x 600 mm
1200 x 600 mm
1800 mm
1800 mm
1200 mm
600 mm
1200 mm
600 mm
0,56 lm
0,56 lm
0,84 lm
1,67 lm
0,84 lm
1,67 lm
3,34 lm
1,67 lm
-
-
-
-
-
-
1,67 lm
-
1,67 lm
-
-
1,12 lm
0,84 lm
1,67 lm
-
0,84 lm
Grid Load Capacities
Prelude Sixty2 System The following table gives the maximum permitted hanger distance (mm) along the double Peakform Main Runner (40 40 93 G) for the tile weights and Main Runner spacings noted.
Tile weight
2,5 kg/m2
3,0 kg/m2
3,5 kg/m2
4,0 kg/m2
5,0 kg/m2
5,5 kg/m2
6,0 kg/m2
7,0 kg/m2
8,5 kg/m2
10,5 kg/m2
13,0 kg/m2
Main Runner spacing 1800 mm 1800 mm Cross Tees31 34 31 A/13 34 32
2300
2200
2150
2100
2000
1900
1850
-
-
-
-
Main Runner spacing 1200 mm 1200 mm Cross Tees31 30 51 B/13 30 31
2400
2400
2350
2300
2200
2150
2100
2050
1900
1700
1550
Main Runner spacing 600 mm 600 mm Cross Tees 31 20 21 A/13 20 31
2400
2400
2400
2400
2400
2400
2400
2400
2300
2200
2100
Hanger spacing
Standard lay-in installation of24 mm exposed suspensionsystem using Board orTegular edge planks.
Gen
eral
App
licat
ions
1) Values in the above table conform to Class 1 as defined in EN 13964:2004+A1:2006 table 6. For other classes /deflection limits please contact your local Armstrong Technical Sales team.
2) Values are determined from laboratory tests methods in accordance with EN 13964:2004+A1:2006 clause 5.
3) Values are applicable for 600 x 600 mm tiles assuming that the maximum deflection of the grid is L/500 but not greater than 4 mm (L = span).
4) No other applied loads such as luminaires, air diffusers, smoke detectors, sprinklers, hanging signs etc. are permitted.
5) No overlays such as mineral wool or fibre glass quilts, as may be required for enhanced acoustic, fire or thermal performance, are permitted unless their full weight is established and included, together with the weight of the tile, within the appropriate weight groups.
6) For grid loading data calculated to different criteria than Class 1 to EN13964:2004+A1:2006, see the grid loading technical section on pages 20 - 21.
46 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
White capping 24 40 42 3600 43 16 57,60 22,20 20
Galvanised capping 24 40 42 UP 3600 43 16 57,60 23,50 20
Black capping 24 40 42 BK 3600 43 16 57,60 22,20 20
Item Nr. Dimensions Content / Carton Weight / Carton Cartons / Pallet length (mm) height (mm) pcs lm kg
PRELUDE 35 XL2
Main Runners Peakform Prelude 35 XL2 (bulb-to-bulb connection)
Cross Tees Peakform Prelude 35 XL2 (stab system, override)
Section Drawings
Perimeter Trim
White capping 24 06 42 1990 43 16 31,80 12,30 2024 36 42 1500 43 32 48,00 16,60 2024 30 42 1200 43 36 43,20 14,90 6024 20 42 600 43 36 21,60 7,50 120
Galvanised capping 24 06 42 UP 1990 43 16 31,80 13,00 2024 36 42 UP 1500 43 32 48,00 17,70 2024 30 42 UP 1200 43 36 43,20 15,90 6024 20 42 UP 600 43 36 21,60 8,00 120
Black capping 24 06 42 BK 1990 43 16 31,80 12,30 2024 36 42 BK 1500 43 32 48,00 16,60 2024 30 42 BK 1200 43 36 43,20 14,90 6024 20 42 BK 600 43 36 21,60 7,50 120
T 3024 H Perimeter angle, White painted 3000 24 40 120,00 28,50 50
T 3030 H* Perimeter angle, White painted 3000 30 30 90,00 25,00 40
* Also available in Galvanised (UP) and Black (BK) Please add the corresponding suffix to the item number when placing the order.
43 mm
35 mm
43 mm
35 mm
43 mm
35 mm
3600 50 100 33 x 100 100 50Length
1200 600 600
Length
1990 / 1500 / 600
Main Runners Prelude 35
Cross Tee Prelude 35 XL2
Cross Tee Prelude 35 XL2
Cross Tee alignment is achieved by locating the tees to the right-hand side of the adjoining section.All dimensions in millimetres. All sizes are nominal.
Gen
eral
App
licat
ions
Exposed 35 mm grid system (nominal).For use in large shed type buildings including retail outlets, industrial manufacturing and meeting halls, etc...
30
30
30
Item Nr. Description Dimensions Content / Carton Weight / Carton Cartons / Pallet length (mm) height (mm) pcs lm kg
47
Gen
eral
App
licat
ionsPRELUDE 35 XL2
Grid Load Capacities
Prelude 35 XL2 System
The following table gives the maximum permitted hanger distance (L) along the Main Runner (24 40 42).
Tile weight
2,5 kg/m2
3,0 kg/m2
3,5 kg/m2
4,0 kg/m2
4,5 kg/m2
5,0 kg/m2
5,5 kg/m2
6,0 kg/m2
6,5 kg/m2
7,0 kg/m2
8,0 kg/m2
9,0 kg/m2
10,0 kg/m2
12,0 kg/m2
14,0 kg/m2
Main Runner spacing 1990 mm (x 1000 mm)
1990 mm XL2 Cross Tee 24 06 42
1700
1600
1550
-
-
-
-
-
-
-
-
-
-
-
-
Main Runner spacing 1500 mm (x 1000 mm)
1500 mm XL2 Cross Tee 24 36 42
1900
1800
1700
1650
1600
1550
1500
1400
1350
1300
1250
-
-
-
-
Main Runner spacing 1200 mm (x 600 mm)
1200 mm XL2 Cross Tee 24 30 42
1900
1850
1750
1700
1650
1600
1550
1500
1500
1450
1400
1300
1250
1150
1050
Main Runner spacing 600 mm (x 600 mm)
600 mm XL2 Cross Tee 24 20 42
2000
2000
2000
2000
2000
2000
1950
1900
1900
1850
1750
1700
1650
1550
1450
Hanger spacing
Key Attributes Physical Data
• Peakform Patented universal Main Runner and Cross Tee design increase strength and stability for improved performance and makes the grid easier to cut
• Rotary stitched Main Runner and Cross Tees for additional torsional strength and extra stability during installation
• Material Double-web galvanised steel
• Surface Finish Baked polyester paint
• Product Family Exposed tee system
• Main Runner / Cross Tee Interface Joggled ends
• End Detail Main Runner : with Superlock clip, by pass coupling, single stitching Cross Tees : staked-on stab clip, double stitching
• Colour Available in White, Galvanised and Black.
Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details.
1) Values in the above table conform to Class 1 as defined in EN 13964:2004+A1:2006 table 6. For other classes /deflection limits please contact your local Armstrong Technical Sales team.
2) Values are determined from laboratory tests methods in accordance with EN 13964:2004+A1:2006 clause 5.
3) Values are applicable for 600 x 600 mm tiles assuming that the maximum deflection of the grid is L/500 but not greater than 4 mm (L = span).
4) No other applied loads such as luminaires, air diffusers, smoke detectors, sprinklers, hanging signs etc. are permitted.
5) No overlays such as mineral wool or fibre glass quilts, as may be required for enhanced acoustic, fire or thermal performance, are permitted unless their full weight is established and included, together with the weight of the tile, within the appropriate weight groups.
6) For grid loading data calculated to different criteria than Class 1 to EN13964:2004+A1:2006, see the grid loading technical section on pages 20 - 21.
48 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
Gen
eral
App
licat
ions BANDRASTER
Slotted at 312,50 mm (1)36 2100 B 3750 100 8 30,00 32,60 16
Slotted at 100 mm (1) 36 3050 3600 50 8 28,80 24,00 2836 3075 3600 75 8 28,80 27,70 2036 3100* 3600 100 8 28,80 31,40 1636 3125 3600 125 8 28,80 38,30 1236 3150 3600 150 4 14,40 21,20 20
Unslotted (2) 36 0050 A 3600 50 8 28,80 24,00 2836 0075 A* 3600 75 8 28,80 27,70 2036 0100 A 3600 100 8 28,80 31,40 1636 0125 A 3600 125 8 28,80 38,30 1236 0150 3600 150 4 14,40 21,20 20
(1) Is compatible with all plank edge details whether cross tees are required or not.
(2) Is compatible with only with plank edge details when no visible cross tees span between bandraster sections.
A 36 0501 Strip / rod connector 50 50 1,20A 36 0751 75 50 1,50A 36 1001 100 50 1,80
A 36 0502 G Nonius hanger 50 100 5,80A 36 0752 G 75 100 8,10A 36 1002 G 100 100 11,00A 36 1252 G 125 100 12,50A 36 1502 G 150 100 15,00
A 36 0503 G Splice 50 100 8,00A 36 0753 G 75 100 8,30A 36 1003 G 100 100 14,00A 36 1253 G 125 100 17,00A 36 1503 G 150 100 19,50
A 36 0504 G Cross connector 50 100 5,80A 36 0754 G 75 100 8,10A 36 1004 G 100 100 11,00A 36 1254 G 125 100 12,50A 36 1504 G 150 50 7,50
A 36 0505 G Wall connector 50 100 5,80A 36 0755 G 75 100 8,10A 36 1005 G 100 100 11,00A 36 1255 G 125 100 12,50A 36 1505 G 150 50 7,50
A 36 0506 G Crossing element 50 48 7,70A 36 0756 G 75 30 5,70A 36 1006 G 100 32 7,40
Item Nr. Dimensions Content / Carton Weight / Carton Cartons / Pallet length (mm) Height (mm) pcs lm kg
Bandraster Systems
Bandraster Accessories
Item Nr. Description Dimension Content / Carton Weight / Carton height (mm) pcs kg
Product available as standard in Global White.
*Also available in RAL 9010 (WR)
36mm
12mm12mm
150 / 125 / 100 / 75 / 50mm150 / 125 / 100 / 75 / 50mm
All measurements in millimetres. All sizes are nominal.
Bandraster is a suspension system available in a wide range of widths, compatible with Prelude 24 TLX/XL2 Cross Tees.
49
Gen
eral
App
licat
ionsBANDRASTER
Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details.
Pin to connect bottom and upper part of NoniusA 10229 G(It is recommended to use 2 pins to connectbottom & upper part of Nonius)
Upper part of Nonius
Splice
Crossing element
Threaded rodA 1829 G
Wall connector
Nonius hanger
Strip / rod connector
Crossconnector
- Slotted Bandraster is compatible either with Prelude 24 XL2 or Prelude 24 TLX Cross Tees - On special request: Prelude 15 TL can be made compatible for installation with slotted Bandraster;- Special spaced slotting; minimum slot spacing is 50 mm; Maximum length of Bandraster is 5000 mm
System Drawing
50 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
Gen
eral
App
licat
ions
CZ 41494 H Deep Z 32 mm 1500 20 30,00 9,40CZ 41794 H Deep Z 32 mm 1800 20 36,00 11,30CZ 41795 H Deep Z 70 mm 2500 10 25,00 13,40
CA 5740 G Double height Z 4000 10 40,00 24,00
CA 5733 A Spacer bar 600/625 50 31,20 7,00
CA 5734 Spacer bar 1200/1250 50 62,50 14,00
CZ 3600 H Z section 3600 20 72,00 22,70
CA 21 G Z connector 150 500 - 10,00
CC 4000 G Channel 13 x 38 mm 4000 20 80,00 26,50C 3000 G Channel 19 x 38 mm 4000 8 32,00 23,80
CA 120 G Preformed channel clip - 100 - 0,50
Item Nr. Description Dimensions Content / Carton Weight / Carton length (mm) pcs lm kg
SYSTEM Z
CC 4000 G
CA 120 G
Semi-Concealed - Compatible with SL2
CZ 3600 H
CA 21 G
Semi-Concealed
All measurements in millimetres. All sizes are nominal.
Semi-concealed and concealed systems.Provides specialist solution for corridors giving a monolithic visual. Can also be used for room situations in conjunction with Prelude 24 and Bandraster grid.
51
CA 97 G Clamp for C-channel 30 100 - 1,70
CT 600 G Noggin tee 600 100 60 8,50
CA 5730 G Anti-breather spline 295 200 - 3,80
SYSTEM Z
CC 4000 G
Item Nr. Description Dimensions Content / Carton Weight / Carton length (mm) pcs lm kg
Semi-Concealed (continued)
Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details.
System Drawing
SL2
Quantities required per 1m2 (no waste included)
13
2 The chart is for general guidance only.
Plank size
1500 x 300 / 312,5 mm1800 x 300 / 312,5 mm2500 x 300 / 312,5 mm
Supportingsections
at
300 / 312,5 mm300 / 312,5 mm300 / 312,5 mm
Z ProfileCZ 41494 H
3,33 / 3,20 lm--
Z ProfileCZ 41794 H
-3,33/3,20 lm
-
Z Profile CZ 41795 H
--
3,33 /3,20 lm
Perimeter trim according to circumference of room Perimeter angles should be of thicker material when corridor wider than 1,80 m.
Semi-concealed SL2Corridor installation
Gen
eral
App
licat
ions
52 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
Gen
eral
App
licat
ions DRYWALL GRID SYSTEM
The Drywall Grid System (DGS) is a quick and easy to install suspension system for plasterboard ceilings, available in a range of two unique systems : Standard for typical flat installations and Faceted for curved and domed ceilings.
Peakform Main Runner and Superlock Clip (bulb to bulb connection)
Accessories
Item Nr. Dimensions Content / Carton Weight / Carton Cartons / Pallet length (mm) height (mm) width (mm) pcs Im kg
Main Runners 7940 G slot at 150mm 3600 38 38 12 43,20 20 367942 G slot at 150mm 3000 38 38 12 36,00 17 36 7941 G slot at 100mm 3600 38 38 12 43,20 19,52 36
Faceted Main Runners HD 8906 F08 G 3658 43 38 12 43,92 22 24HD 8906 F16 G 3658 43 38 12 43,92 22 24
Cross Tees7930 G 1200 38 38 36 43,20 20 487918 900 38 38 36 33,00 15 487920 G 600 38 38 36 21,60 10 96
Unhemmed C channel7838 G 3048 (120") 40 20 60.96 16 32
Knurled angle trimKAM 12 H 3658 (12') 32 32 30 109.72 26 12
19
43
A variety of Drywall Grid accessories are available to provide problem solving solutions that save time, labour and money.
Item Nr. ImageItem Nr. Image Item Nr. Image
DWACS AGDrywall attachment clip
DW30C AG DW45C AG DW60C AG DW90C AGDrywall angle clips
RC2 AG Radius clip
MBAC AG Main Runner adapter clip
DW50 LTTransition clip13 mmplasterboard (1/2")
DW58 LTAG Transition clip for 15 mmplasterboard (5/8")
MBSC2 AGMain Runner spacer clip
XTAC AG Cross Tee adapter clip
DLCC AG Direct load ceiling clip
BP DWC AGDrywall clip
All measurements in millimetres. All sizes are nominal.
53
DRYWALL GRID SYSTEM
Section Drawing
Gen
eral
App
licat
ions
Faceted Main Runners faceted at 203mm centres. Use for radius 4.50m or less
Faceted at 406mm centres. Use for radius over 4.50m (directional Main Runner)
Cross Tees
Length
7940 G 3600mm7941 G 3600mm7942 G 3000mm
HD 8906 F08 G
HD 8906 F16 G
7930 G
7920 G
7918 G
(45 slots) 3658mm
1200mm
600mm
900mm
(54 slots) 3658mm
Hanger wire or suspension angleVertical brace
Main Runner
Cross Tee
Main Runner
System Drawing
For more information, please ask for the Drywall Grid System Curved and Flat brochure.
Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details.
75 mm50 mm75 mm
23 x 150 mm35 x 100 mm19 x 150 mm
75 mm50 mm75 mm
54 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
Cor
ridor DRYWALL GRID SYSTEM SHORTSPAN
System Drawing
Drywall Grid System (DGS) Shortspan product range
The Drywall Grid System (DGS) ShortSpan is a quick and easy to install suspension system forplasterboard ceilings and in particular for corridors in both commercial and residential installations.
Lockingtab
The gap between walltrim and shortspanshould not be over 3mm
LAT 12/10 Hmust be screwedto wall structure
Alignmentcrimps
Locking tabsat 150/100mmcentres.
150/100mm
S 7708 G 2438 (8') 38 12 29,26 13 24
S 7710 G 3048 (10') 38 12 36,57 17 24
S 7712 G 3658 (12') 38 12 43,89 20 24
S 7714 G 4267 (14') 38 12 51,20 23 24
LAT 12 H 3600 32 30 109,72 18 12
LAT 10 H 3600 30 30 110,00 15 12
KAM 12 B 3660 (12') 32 10 36.60 9 50
Item Nr. Dimensions Content / Carton Weight / Carton Cartons / Pallet length(mm) height (mm) pcs Im kg
Shortspan T-bars
Locking angle trimsLocking tabs at 150mm for the BP LAT 12HLocking tabs at 100mm for the BP LAT 10H
Knurled angle trim
The ShortSpan system is designed for use in drywall ceilings where the spans do not exceed 4200mm.
The individual ShortSpan tees are not designed to be used independent of the locking angle trim (LAT 12 H) or optional knurled angle trim (KAM 12 B).
For more information, please ask for the Drywall Grid System Standard and Faceted brochure.
55
Universal Main Runner Prelude Sixty2 Double Peakform and Superlock Clip (bulb to bulb connection)
Cor
ridor
Planks
Perimeter trim
Double bent teebar hanger
PRELUDE SIXTY2Exposed 24 mm grid system.
Double Peakform Main Runner section requiring less suspension points and compatible with Prelude 24 XL2 and TLX Cross Tees.
System Drawing
(1) Colours available: Carrara (CA), Platinum (PN), Black (BK), RAL 9006 (SG), Chrome (CE), White RAL 9010 (WR), Brass (BS).
Accessories
Item Nr. Description Dimensions Content / Carton Weight / Carton Length (mm) Height (mm) pcs kg
A WDN23 G Double bent tee bar hanger 57 36 100 2,30
Grid Load Capacities
Spacing (mm) 1600 1700 1800 1900 2000 2100 2200 2300 2400 2500 2600 2700 2800 2900 3000 Prelude Sixty2 300 37,2 32,8 29,1 25,9 23,2 20,9 18,9 17,2 15,6 14,3 13,1 11,8 10,0 8,5 7,1
Butt cut 600 18,6 16,4 14,5 13,0 11,6 10,5 9,5 8,6 7,8 7,1 6,5 5,9 5,0 4,2 3,5
1200 9,3 8,2 7,3 6,5 5,8 5,2 4,7 4,3 3,9 3,5 3,2 - - - -
Span in mm - Load capacities in kg/m2
1) Values in the above table conform to Class 1 as defined in EN 13964:2004+A1:2006 table 6. For other classes /deflection limits please contact your local Armstrong Technical Sales team.
2) Values are determined from laboratory tests methods in accordance with EN 13964:2004+A1:2006 clause 5.
3) Values are applicable for 600 x 600 mm tiles assuming that the maximum deflection of the grid is L/500 but not greater than 4 mm (L = span).
4) No other applied loads such as luminaires, air diffusers, smoke detectors, sprinklers, hanging signs etc. are permitted.
5) No overlays such as mineral wool or fibre glass quilts, as may be required for enhanced acoustic, fire or thermal performance, are permitted unless their full weight is established and included, together with the weight of the tile, within the appropriate weight groups.
6) For grid loading data calculated to different criteria than Class 1 to EN13964:2004+A1:2006, see the grid loading technical section on pages 20 - 21.
The Prelude Sixty2 system is designed for use in corridor applications, with or withoutCross Tees, and where spans do not exceed 3750 mm. For a wider configuration, theMain Runner is compatible with the Prelude 24 TLX and XL2 Cross Tees.
Special length and modulation made to order, with and without slots, please contactyour Armstrong Technical Sales team.
56 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
Spe
cific
App
licat
ions CLEAN ROOM GRID SYSTEM
Main Runner Clean Room Grid System 24
Section Drawings
Cross Tees Clean Room Grid System 24 + Perimeter Trim
Accessories
Item Nr. Dimensions Content /Carton Weight/Carton Cartons/Pallet length (mm) height (mm) pcs lm kg
EA 794044 3600 43 20 72,00 24,00 30
EA 793044 1200 43 60 72,00 26,00 20
EA 792044 600 43 60 36,00 12,00 40
EA 7801 3660 24 30 109,80 20,00 25
150 1503600 300 3009 x 300
300 300
300 300
300 3001200
600
18
12 16
CHDC Hold down clip suitable for non-magnetic areas
A 426 Board access clip
Main Runner Clean Room Grid 24
Cross Tee Clean Room Grid 24
Length
Length
Exposed 24 mm grid system (nominal). A complete system solution: Aluminium construction for maximum corrosionresistance and non-magnetic environments. Co-extruded with a unique factory applied gasket for a better seal betweentile and grid. System suitable for use in applications up to Class 4 performance as per Class ISO standard 14644-1.
All measurements in millimetres. All sizes are nominal.Please contact Armstrong Technical Sales for further details.
57
Spe
cific
App
licat
ionsCLEAN ROOM GRID SYSTEM
Grid Load Capacities
Tile weight Main Runner spacing 1200 mm Main Runner spacing 600 mm 1200 mm Cross Tee 600 mm Cross Tee EA 793044 EA 792044
Clean Room Grid 24 mm The table gives the maximum permitted hanger distance (mm) along the Clean Room Grid Main Runner (EA 794044) for the tile weights and Main Runner spacings noted.
1850
1750
1700
1650
1550
1500
1450
1400
1300
1200
1050
2,5 kg/m2
3,0 kg/m2
3,5 kg/m2
4,0 kg/m2
5,0 kg/m2
5,5 kg/m2
6,0 kg/m2
7,0 kg/m2
8,5 kg/m2
10,5 kg/m2
13,0 kg/m2
2100
2100
2100
2050
1950
1900
1850
1800
1700
1600
1450
Hanger spacing
All measurements in millimetres. All sizes are nominal.Please contact Armstrong Technical Sales for further details.
1) Values in the above table conform to Class 1 as defined in EN 13964:2004+A1:2006 table 6. For other classes /deflection limits please contact your local Armstrong Technical Sales team.
2) Values are determined from laboratory tests methods in accordance with EN 13964:2004+A1:2006 clause 5.
3) Values are applicable for 600 x 600 mm tiles assuming that the maximum deflection of the grid is L/500 but not greater than 4 mm (L = span).
4) No other applied loads such as luminaires, air diffusers, smoke detectors, sprinklers, hanging signs etc. are permitted.
5) No overlays such as mineral wool or fibre glass quilts, as may be required for enhanced acoustic, fire or thermal performance, are permitted unless their full weight is established and included, together with the weight of the tile, within the appropriate weight groups.
6) For grid loading data calculated to different criteria than Class 1 to EN13964:2004+A1:2006, see the grid loading technical section on pages 20 - 21.
Key Attributes Physical Data
• Aluminium construction for maximum corrosion resistance and non-magnetic environments
• Unique co-extruded section aluminium based
• Unique, factory applied gasket for a better seal between tile and grid
• Staked on Main Runner splice for easy connections,
integral hook Cross Tee end detail
• Hold down clips to ensure a good seal
• System suitable for use in applications up to Class 4
performance per ISO standard 14644-1
• Material Co-Extruded Aluminium – Gasketed
• Cross Tee/Main Runner Interface Co-Extruded Aluminium Clean Room – Flush Fit
• Product family Exposed grid system
• End Detail Main Runner: Staked-on clip Cross Tee: Integral hook
Clean Room Main Runner
Clean Room Hold-down clip (CHDC)
Clean Room Cross Tee
Board Tile
58 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
Spe
cific
App
licat
ions PRELUDE 24 CORROSIVE RESISTANT
28 40 42 3600 43 20 72,00 21,00 3028 41 42 3750 43 20 75,00 21,90 30
Item Nr. Dimensions Content / Carton Weight / Carton Cartons / Pallet length (mm) height (mm) pcs lm kg
Universal Main Runners 24 Corrosive Resistant Peakform and Superlock Clip (bulb to bulb connection)
14 30 32 1200 38 60 72,00 18,20 7214 31 32 1250 38 60 75,00 18,90 72
14 20 32 600 38 60 36,00 9,10 14414 21 32 625 38 60 37,50 9,50 144
Cross Tees TLX 24 Corrosive Resistant (Hook system, butt cut)
Section Drawings
Main Runner 24 Corrosive Resistant
Cross Tee TLX 24 Corrosive Resistant Cross Tee TLX 24 Corrosive Resistant
3750 78,125 156,25 21 x 156,25 156,25 78,125 3600 50 100 33 x 100 100 50
1200 300 300 300 300
1250 312,5 312,5 312,5 312,5
600/ 625
Availability of products may vary according to location.
Length
Length
Perimeter Solution
Accessories - Corrosion resistance 700 hours salt spray test
Item Nr. Description Dimensions Content / Carton Weight / Carton length (mm) height (mm) pcs Im kg
T 1924 LB Corrosive resistant 3050 24 36 109,80 27,60 perimeter angle
A WDNCR 20 H Bent tee bar hangerfor threaded rod
A CR1829 G 1000mm Threaded rod dia. 6 mm
A CR1827 G Nut for threaded rod
A CR7890 G Universal retaining clip
A CR827 G 1700 mmhanger withhook
A CR11 G Small hook
A CR12 G Butterfly
T 1924 LB Corrosiveresistant suspensionangle
Exposed 24 mm grid system (nominal).Special paint finish and TLX steel-based composite clip for enhanced corrosion resistance.Corrosion resistance 700 hours salt spray test on grids according to EN ISO 9227 standards.Durability Class C (EN13964:2004 + A1:2006)
For loading data please see standard versions of these items on pages 66-67.
59
Spe
cific
App
licat
ions
Tile Main Runner Hanger Main Runner Cross Tee Cross Tee Hanger Universal centres centres 1200 mm 600 mm Retaining Clip
1200 x 600 mm 1,39 pcs
600 x 600 mm 2,78 pcs
System Drawing (module 1200 x 600 mm)
6 1 2 3 4 7
5
Standard lay-in installation of 24 mm exposed suspension system using Board or Tegular edge tiles.
The chart is for general guidance only.
Quantities required per 1m2 (no waste included)
Perimeter Trim approx. 0,70 lm/m2
1200 mm
600 mm
1200 mm
600 mm
1200 mm
1200 mm
1200 mm
1200 mm
0,84 lm
1,67 lm
0,84 lm
1,67 lm
1,67 lm
-
1,67 lm
-
-
0,84 lm
0,84 lm
1,67 lm
0,70 pcs
1,40 pcs
0,70 pcs
1,40 pcs
5,56 pcs
5,56 pcs
5,56 pcs
5,56 pcs
Grid Load Capacities
Prelude 24 Corrosive Resistant The following table gives the maximum permitted hanger distance (mm) along the Peakform Main Runner (28 40 42) for the tile weights and Main Runner spacings noted.
Tile weight
2,5 kg/m2
3,0 kg/m2
3,5 kg/m2
4,0 kg/m2
5,0 kg/m2
5,5 kg/m2
6,0 kg/m2
7,0 kg/m2
8,5 kg/m2
10,5 kg/m2
13,0 kg/m2
Main Runner spacing 1200 mm 1200 mm Cross Tee
14 30 32
1900
1800
1750
1700
1600
1550
1500
1450
1300
1200
1050
Main Runner spacing 600 mm 600 mm Cross Tee
14 20 32
2100
2100
2100
2100
2000
1950
1900
1800
1700
1600
1500
Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details.
Hanger spacing
*reduce to 450 if heavy tile / overlays areused or heavy service fittings are locatednear the perimeter.
PRELUDE 24 CORROSIVE RESISTANT
1) Values in the above table conform to Class 1 as defined in EN 13964:2004+A1:2006 table 6. For other classes /deflection limits please contact your local Armstrong Technical Sales team.
2) Values are determined from laboratory tests methods in accordance with EN 13964:2004+A1:2006 clause 5.
3) Values are applicable for 600 x 600 mm tiles assuming that the maximum deflection of the grid is L/500 but not greater than 4 mm (L = span).
4) No other applied loads such as luminaires, air diffusers, smoke detectors, sprinklers, hanging signs etc. are permitted.
5) No overlays such as mineral wool or fibre glass quilts, as may be required for enhanced acoustic, fire or thermal performance, are permitted unless their full weight is established and included, together with the weight of the tile, within the appropriate weight groups.
6) For grid loading data calculated to different criteria than Class 1 to EN13964:2004+A1:2006, see the grid loading technical section on pages 20 - 21.
60 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
Spe
cific
App
licat
ions SEISMIC Rx®SYSTEM
T 3024 H Perimeter angle, 3000 40 28,50 50painted
BERC2 Main Runner 50 200 9,00 36end retaining clip
SJCG Seismic joint clip - 200 7,00 36XL2 Cross Tee (24mm)
SJMR15 Seismic joint clip - 100 11,00 60Peakform Main Runner (24mm)
ES 4 Expansion sleeve (24mm) 100 100 1,00 170
442 Vector Seismic clip - 100 1,63 -
31 30 51 B(1) 1200 38 60 72,00 18,20 7231 31 51 B(1) 1250 38 60 75,00 18,90 72
31 20 21 A(1) 600 30 60 36,00 8,20 14431 21 23 A(1) 625 30 60 37,50 8,60 144
31 40 32 A(1) 3600 43 20 72,00 21,00 3031 41 33 B 3750 43 20 67,50 20,00 30
Item Nr. Dimensions Content / Carton Weight / Carton Cartons / Pallet length (mm) height (mm) pcs lm kg
Cross Tees Prelude 24 XL2 (stab system, override)
Accessories
Universal Main Runners Prelude 24 Peakform and Superlock Clip (bulb-to-bulb connection)
Availability of products may vary according to location.
Exposed 24mm grid system (nominal).Independently tested approach using Prelude XL2 grid to achieve ceiling installations that can withstand the forcesassociated with significant seismic activity or other severe events.
Cross Tees slotted
Cross Tees unslotted
Item Nr. Description Dimensions Quantity / Carton Weight / Carton Cartons / length (mm) pcs kg Pallet
(1) Standard Colours available : BK (Black), CA (Carrara), PN (Platinum), BS (Brass), CE (Chrome), SG (RAL9006),WR (RAL 9010). A further 180 RAL colours are available as a special on request. Please contact your local sales office.
Attached Wall
Una
ttac
hed
Wal
l
Unattached Wall
A A A
B
MainRunner
600mmc/c
Hanger Wire
MainRunner
B
B
B
B
B
B
B B B
B
x
x
x x
x
x
x
x
x
61
Spe
cific
App
licat
ions
System Drawing
Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details.
SEISMIC Rx®SYSTEM
Note: some recommendations / guidelines require additional hangers onperimeter Cross Tees within 200mm of the perimeter. This is not arequirement of the Seismic Rx®solution using the BERC2 clip, butmay also be incorporated to provide additional system security in veryhigh hazard areas e.g. emergency services control centre, where fullfunctionality is planned post event.
200mm MAXTight Screw
30 mm
Attached Wall Detail
Optional Screw
200mm MAX
Unattached Wall Detail
30mm20mm
• T 3024 H perimeter trim• BERC2 on all (four) sides of room prevents ends of
Cross Tees and Main Runners from spreading apart• 20mm clearance on two adjacent sides and 10mm
overlap of grid on the perimeter trim
62
Spe
cific
App
licat
ions LONGSPAN SYSTEM
LP 546 G 5000 54 5 25,00 18,40 10LP 706 G 5000 70 5 25,00 23,60 10LP 856 G 5000 85 5 25,00 25,10 10LP 120 G 6500 120 5 32,50 63,30 10
Item Nr. Dimensions Content / Carton Weight / Carton Cartons / Pallet length (mm) height (mm) pcs lm kg
Primary Channels
Accessories
A 4510 G Bent hanger for T profile - 50 2,00
A 1820 G Beam flange clip 47 100 2,20A 1821 G 47 100 3,20
A B11067 G Special holding clamp* 54 100 3,10A B11066 G 70 100 4,30A B11065 G 85 100 4,60A B11064 G 120 50 3,30
A M4538 G Wall connection 54 25 1,30A M4536 G 70 25 1,70A M4534 G 85 25 3,20A M4529 G 120 25 5,90
A R4537 G Connector 54 25 1,90A R4535 G 70 25 2,30A R4533 G 85 25 4,20A R4528 G 120 25 7,00
CC 4000 G Channel 13 x 38 mm 38 20 26,50CA 120 G Preformed channel clip** - 100 0,50
Item Nr. Description Dimensions Content / Carton Weight / Carton height (mm) pcs kg
85mm
120mm
40mm40mm 40mm40mm
54mm70mm
40mm40mm 40mm40mm
h
*Both Bent hanger for T profile and special holding clamp only work with threaded rod A 1829 G+ Connector A1839 G + nut (A 1827 G)**Install one clip on each side of the Channel CC 4000 GAll measurements in millimetres. All sizes are nominal.
LongSpan Grids are designed to create a primary framework underneath beams or between walls, therebyallowing the suspended ceiling Main Runners to be installed with fewer suspension points.
CC 4000 G
CA 120 G
www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
L O N G S PA N S Y S T E M
System Drawing
Grid Load Capacities (LongSpan System) Space 1200 mm
Note: Uniformly distributed load kg/m2.Load charges in kg/m2 for deflection L/300.
1200
1200
AM 45....Wall connector
AR 45.....Connector
A 4510 GBent hanger for T profile
A 182 ...Beam flange clip
LP...Primary channel
Note :- Two wall connectors AM 45... must be
used to fix to walls.- Two connectors AR 45... must be used
when connecting two lengths of Primary Channel together.
- Two preformed channel clips CA 120 Gmust be installed on the opposites sides ofthe Primary channel
AB 11...Special holding clamp
CC 4000 GChannel (tie bar)
Steel beam
CA 120 GPreformed channel clip
Threaded rod A 1829 G + ConnectorA 1839 G + Nut A 1827 G
Steel beam
1 tie bar 2 tie bars 3 tie barsSpacing between suspensions (m) 1,25 1,50 1,75 2,00 2,25 2,50 2,75 3,00 3,25 3,50 3,75 4,00 4,25 4,50 4,75 5,00 5,50 5,75 6,00 6,50
Item Nr. LP 546 G kg/m2 48 48 32 23 16 12 9
LP 706 G kg/m2 48 34 25 19 14 11 9 7 6
LP 856 G kg/m2 48 42 25 19 15 12 10 8 7 7
LP 120 G kg/m2 48 30 24 20 17 14 12 10 9 8 6
63
Spe
cific
App
licat
ions
Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details.
64 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
White FT 2424 2500 24 10 25,00 5,50 50FT 1929 2500 29 10 25,00 5,50 50
BlackFT 2424 BK 2500 24 10 25,00 5,50 50FT 1929 BK 2500 29 10 25,00 5,50 50
Item Nr. Dimensions Content / Carton Weight / Carton Cartons / Pallet length (mm) height (mm) pcs lm kg
FLEXIBLE PERIMETER TRIMS
Perimeter Trims
Accessory
Per
imet
er S
olut
ions
Excellent solution for finishing ceilings around columns and convex walls, easily cut and curved by hand on site.
24 mm
24 mm
29 mm
19 mm
Item Nr. Description Dimensions Content / Carton Weight / Carton length (mm) height (mm) pcs kg
A WDN 23 G Double bent tee bar hanger 57 36 100 2,30
Key Attributes Physical Data
• Optimum length for most columns with a 2.5 m length
• Easy to cut and to bend to necessary radius
• Available in 2 colours (White and Black)
• 3 ply white PVC tape for a better visual
• Quick fix for columns and convex curves
• Material Steel core with PVC tape
• Product Family Perimeter Trims
• Coating PVC
• Colour Available in Global White and Black.
65
Per
imet
er S
olut
ionsFLEXIBLE PERIMETER TRIMS
Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details.
Perimeter Detailing
1 The white Flexible trim has THREE layers of white PVC coating to avoid the ‘greyish’ visual appearance between the steel supported zone ‘G’ and the PVC only zone ‘P’.
2 The Flexible trim should follow the same rule of being fixed onto the wall with 450 mm spacing.
3 These trims are considered decorative elements therefore any grid laying on them will need :
Note:These trims can be used only in curved TOE OUT ( Convex ) installations (19 x 29 section must be installed with the 29 mm face vertical).
Minimum bending radius : 200 mm.
Minimum environment temperature during the curving operation : 20ºC.
Due to the nature of the PVC coating, these trims do not exactly match our standard black & white colour and gloss.
Fire reaction classification Euroclass F (EN 13501-1) - please check local/country regulations for compliance.
450
PG
50 mm 50 mm
Pillar
A) A hanger support onto thegrid laid onto the flexible trimas close as possible from the edge of the trim.
B) Use the accessory A WDN 23 G to supportthe load above the trim.
66 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
Min
eral
Per
imet
er S
olut
ions
PERIMETER SOLUTIONS
T 1924 HD Perimeter angle, painted 3000 0,54 36 108,00 22,70
T 1924 CA(1) Perimeter angle, capped 3050 0,60 36 109,80 27,60
T 1924 LB Perimeter angle, 3050 0,55 36 109,80 27,60 corrosive resistant
T 1932 HA Perimeter angle, painted 3000 0,45 36 108,00 21,80
T 1919 HC Perimeter angle, painted 3000 0,45 36 108,00 19,30
T 2401 H Perimeter angle, painted heavy duty 3050 0,70 30 91,50 22,00T 2400 H Perimeter angle, painted 3050 0,60 30 91,50 20,00 intermediate duty
T 2424 HC Perimeter angle, painted 3050 0,45 36 109,80 21,60
T 3024 H Perimeter angle, painted 3000 0,45 40 120,00 28,50
T 3030 H Perimeter angle, painted 3000 0,54 30 90,00 25,00
T 1506 H Shadowline, painted 3050 0,45 36 109,80 26,30
T 1508 HB Shadowline, painted 3050 0,45 36 109,80 27,10
T 2020 HH Shadowline, painted 3000 0,65 20 60,00 27,00
7875 G Shadowline, painted, 3050 0,45 30 91,50 26,80 for Optima Vector, Ultima Vector, Dune Vector
T 2121 HG Shadowline, air circulation length 3000 0,60 25 75,00 41,20 of slot: 50 mm Distance between slots 20 mm (ca. 16% open area)
T 2040 HB C channel, painted 3050 0,45 20 61,00 18,10
T 7837 C channel, painted 3050 0,45 40 73,10 24,00
Item Nr. Description Dimensions Content / Carton Weight / Carton length (mm) thickness (mm) pcs lm kg
All products standard in Global White. Other standard colours available for item numbers with index (1). See details below.(1) Colours available : Carrara (CA), Platinum (PN), Black (BK), RAL 9006 (SG), Brass (BS), Chrome (CE), White RAL 9010 (WR), Opal (OL), Brown (BN), Ivory (IY), Blue (BE), Red (RD), Green (GN). All measurements in millimetres. All sizes are nominal.
A comprehensive range of the most commonly used perimeter profiles, including shadowline, F upstands andcover plates, finished to match all Prelude 24 mm and 15 mm, Bandraster and Prelude 35 grid systems.
30
30
30
67
Min
eral
Per
imet
er S
olut
ions
PERIMETER SOLUTIONSMineral suspension system.
Perimeter Detailing
Perimeter Trims
T 2040 H WR A C channel, 3050 0,50 20 61,00 18,10 colour RAL 9010
T 2040 H SG A C channel 3050 0,45 20 61,00 18,10 colour RAL 9006
T 1575 HA Unequal U-Profile, 3050 0,45 36 109,80 24,20 painted
7856 H F Upstand trim, 3050 0,45 20 61,00 23,70 painted, for 16 mm thick panels
7852 H F Upstand trim, 3050 0,45 20 61,00 23,00 painted, for 13 mm thick panels
Item Nr. Description Dimensions Content / Carton Weight / Carton length (mm) thickness (mm) pcs lm kg
Standard perimeter finish with perimeter angleT 1924 HD or T 1924 CA
Perimeter finish with C channel T 2040 HA1 A 7890 G Universal retaining clip
A 1796 GPerimeter wall spring
Perimeter finish with unequal U-Profile T 1575 HAPerimeter finish with shadowline T 1506 H
24
19
25
6
15 15
ca. 300 ca. 300
ca. 300ca. 300
40
20
32
15 7,5
1
Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details.
A 156 G / A 246 G Perimeter fill-in for Tegular and MicroLook tiles
68 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
PERIMETER SOLUTIONS
T 2040 H WR A Perimeter channel RAL 9010 20x40 mm 3050 20 61,00 18,10
C 1803 H Perimeter wedge 200 100 - 5,00
M 215013 Perimeter trim RAL 9010 25x 25 mm 4000 10 40,00 8,00
M 215014 Shadowline RAL9010 20x20x20x25 mm 4000 10 40,00 13,50
M 215015 Shadowline RAL9010 20x15x10x25 mm 4000 10 40,00 11,00
M 311081 Cut tile spring wedge 40 100 - 0,30
Perimeter trims also available in Global White.
Perimeter Trims for Metal Ceilings
Item Nr. Description Dimensions Content / Carton Weight / Carton length (mm) pcs lm kg
Met
al P
erim
eter
Sol
utio
ns
Metal suspension system.
69
Perimeter Detailing for Metal Ceilings
25
25
20
10
15 25
40
20
M 311081 – Cut tile spring wedge
M 215013 – Aluminium perimeter angle trim
T 2040 H WR APerimeter channel and perimeter wedge for cut modules
C 1803 H
M 215015 Aluminium shadowline trim
Cut Tile Spring Wedge M 311081 -1-2 pieces per 300mm of perimeter trim.
Perimeter wedge C 1803 H -1 piece per 300mm of perimeter trim.
M 311081
All measurements in millimetres. All sizes are nominal.
Met
al P
erim
eter
Sol
utio
ns
PERIMETER SOLUTIONSMetal suspension system.
70 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
Acc
esso
ries
ACCESSORIES
A W950 G Suspension wire dia. 2 mm ca. 200 metres 1 coil 4,70 41
A 1843 G Expanded bolt for threaded rod dia. 6 mm 25 100 0,50
A 1829 G Threaded rod dia. 6 mm 1000 50 8,50
A 1839 G Connection for threaded rod dia. 6 mm 20 100 0,60
A 1827 G Nut for threaded rod 100 0,20
A WDN20 H Bent tee bar hanger for threaded rod 57 100 1,40
20 (tested withA 14 G Universal clip 40 100 1,00 6 mm threaded rod)
A WDN21 H T bar hanger - 20 0,30 32
A WDN23 G Double bent T bar hanger with 57 100 2,30 32 2 sizes of diameter hole
A 11030 G Quick hanger - hook (2 hooks) 165-280 100 5,40
A 11020 G Quick hanger - hook (2 hooks) 215-380 100 4,10
A 11040 G Quick hanger - hook (2 hooks) 315-580 100 8,50 41
A 11070 G Quick hanger - hook (2 hooks) 415-780 100 10,50
A 11090 G Quick hanger - hook (2 hooks) 515-980 100 13,00
A 12030 G Quick hanger - eye (1 hook +1 eye) 165-280 100 5,20
A 12020 G Quick hanger - eye (1 hook +1 eye) 215-380 100 4,10
A 12040 G Quick hanger - eye (1 hook +1 eye) 315-580 100 8,30 41
A 12070 G Quick hanger - eye (1 hook +1 eye) 415-780 100 10,50
A 12090 G Quick hanger - eye (1 hook +1 eye) 515-980 100 13,00
Item Nr. Description Dimensions Content / Carton Weight / Carton Admissible Load * length (mm) pcs kg kg
Suspension & Accessories
* Note: These admissible loads have been determined from laboratory tests in accordance with EN 13964 : 2004 + A1 : 2006 and applyto the hangers and their grid connections only.No account has been taken of the strength of top fixings which must be selected as appropriate for the supporting structure andestimated load.
71
Suspension & Accessories
Item Nr. Description Dimensions Content / Carton Weight / Carton Admissible Load * length (mm) pcs kg kg
* Note: These admissible loads have been determined from laboratory tests in accordance with EN 13964 : 2004 and apply to the hangers and their grid connections only.No account has been taken of the strength of top fixings which must be selected as appropriate for the supporting structure and estimated load.
Availability of products may vary according to location.All measurements in millimetres. All sizes are nominal.Please contact Armstrong Technical Sales for further details.
60
190
A 10202 H Upper part of nonius 300 100 5,10
A 10203 H Upper part of nonius 400 100 7,20
A 10204 H Upper part of nonius 500 100 9,00
A 10205 H Upper part of nonius 600 100 11,00
A 10206 H Upper part of nonius 700 100 12,80
A 10208 H Upper part of nonius 800 100 15,50
33
A 10230 G Bottom part of nonius hanger 190 100 4,30
A 10229 G Pin to connect bottom 60 100 0,80
& upper part of nonius
A 952 G Suspension angle 3600 20 13,30
A 826 G 2 m hanger with hook 2000 100 20,00
A 827 G 1,7 m hanger with hook 1700 100 20,00
A 11 G Small hook 120 100 2,00
A 12 H Butterfly 55 100 1,00
A 829 H Suspension hanger for T bar 130 100 2,80 33
ACCESSORIES
Acc
esso
ries
72 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
Acc
esso
ries
Suspension & Hold Down Clips
A 1837 G Rocking hanger 82 100 2,00
A 1838 G Hanger for wooden beam 148 100 3,20
A 1820 G Beam flange clip 1,6 - 4,8 mm thickness - 100 2,20
A 1821 G Beam flange clip 4,8 - 9,5 mm thickness - 100 3,20
A 1822 G Clip for quick hanger 1,6 - 4,8 mm thickness - 100 0,80
A 1823 G Clip for quick hanger 4,8 - 9,5 mm thickness - 100 3,00
A 7890 G Universal retaining clip - 100 0,40
A 819 G Locking hold down clip, for 6 - 30mm tiles 64 500 2,40 (Peakform & Square bulb)
A 1060 T35 Hold down clip for panels - 250 3,10 up to 110 mm thick
Item Nr. Description Dimensions Content / Carton Weight / Carton length (mm) pcs kg
82 10
148
18
55
38
A 1829
38
ACCESSORIES
73
Hold Down Clips & Accessories
Item Nr. Description Dimensions Content / Carton Weight / Carton length (mm) pcs kg
EHDC 58 AG Exterior hold down clip 102 125 7,00
(Peakform & Square bulb)
A 7912 G Hold down clip for 40 mm soft 68 100 1,10 fibre panels
A 7902 G Hold down clip for 18-25 mm soft 40 100 1,10 fibre panels
A 426 Board access clip - 100 0,40
A 7930 G Last tile clip Tegular 40 25 0,05
A 7931 G Last tile clip MicroLook 40 25 0,05
MCC4 G Mitre closure clip for - 200 0,30 6 mm Silhouette & Microline
LFC G Peakform Corner support of lay-in light - 50 0,45 (Silhouette & Microline 15 mm grid)
A 131 G T bar saddle clip (Peakform & Square bulb) 98 100 2,70
70 102
23
66
22
50
32
38
8
424
1. 2. 3.
18
12 16
Availability of products may vary according to location. All measurements in millimetres. All sizes are nominal.Please contact Armstrong Technical Sales for further details.
Acc
esso
riesACCESSORIES
74 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
Acc
esso
ries
Perimeter Accessories
A 328 G Inside corner 19 mm 58 100 0,90
A 329 G Outside corner 19 mm 65,50 100 1,20
A 330 G Inside corner 24 mm 58 100 0,90
A 331 G Outside corner 24 mm 65,50 100 1,20
A 332 G Inside corner for shadowline T 1508 HB 72 100 1,60
A 333 G Outside corner for shadowline T 1508 HB 57,20 100 1,20
A 0415 G MicroLook border clip 19 500 0,80
A 0324 G Tegular border clip 29 500 1,20
A 156 G Perimeter fill-in for 15 mm grid - 500 0,40
A 246 G Perimeter fill-in for 24 mm grid - 500 0,50
15136
1975
75
o
2413
6
29o
15
246
6,5
Item Nr. Description Dimensions Content / Carton Weight / Carton length (mm) pcs kg
ACCESSORIES
WESTERN EUROPEBelgium & LuxembourgArmstrong Building Products B.V.Bureaux Commerciaux BelgiquePostbus 38034800 DV BredaNederlandTel.: (+32) 02 223 00 72Fax: (+31) 076 521 04 07e-mail: [email protected]
Germany & SwitzerlandArmstrong Building ProductsKundenserviceOffice Building QuadriumClaudius Prinsenlaan 1264818 CP BredaNiederlandeTel.: (+49) 0251 7603 210Fax: (+49) 0251 7603 593e-mail: deutsche-info@armstrong.comwww.armstrong-decken.dewww.armstrong-decken.atwww.armstrong.ch
Armstrong Metalldecken AGBreitfeldstrasse 89015 st. GallenSwitzerlandTel.: +41 (0) 71 313 63 63Fax: +41 (0) 71 313 64 00
ZentralschweizArmstrong Metalldecken AGBu� ro / Lager ZentralschweizGrossweid 9CH-6026 rainTel.: +41 (0) 41 921 63 63Fax: +41 (0) 41 921 63 80
Suisse RomandeArmstrong Plafonds Métalliques SABureau Suisse Romande3, Rue Gustave-MonynierCH-1202 GenèveTel.: +41 (0) 22 731 60 70Fax: +41 (0) 22 731 60 74
Austria/Eastern EuropeArmstrong Metalldecken GmbHBundesstrasse 70A-6830 RankweilTel.: +43 (0) 55 22 34 44-0Fax: +43 (0) 55 22 34 44-8
Armstrong Metalldecken GmbHMessendorferstrasse 6A-8041 GrazTel.: +43 (0) 31 64 71 584Fax: +43 (0) 31 64 71 584-10
SpainArmstrong Building ProductsOficina de ventas EspañaImmeuble Paryseine3 Allée de la Seine94854 Ivry-sur-SeineFranciaTel.: (+ 34) 91 642 04 9900 800 90 21 03 68Fax: (+33) 1 4521 04 11e-mail: [email protected]/techos
PortugalArmstrong Floor ProductRua de Manuel Assunçao de Falcao, 634475-041 Santa Maria de Avioso - MaiaPortugalTel.: (+351) 22 982 81 10Fax: (+351) 22 982 81 19e-mail: [email protected]
France & French Speaking AfricaArmstrong Building Products SASBureaux Commerciaux FranceImmeuble Paryseine3 Allée de la Seine94854 Ivry-sur-seineTel.: 0800 41 36 43Fax: (+33) 1 45 21 04 11e-mail: [email protected]/plafonds
Siège socialArmstrong Building Products SAS67 Rue de SalinsBp 8925300 PontarlierFrance
Italy & GreeceArmstrong Building ProductsUfficio Commerciale ItaliaImmeuble Paryseine3 Allée de la Seine94854 Ivry-sur-SeineFranciaTel.: (+39) 02 66 22 76 50Fax: (+39) 02 66 20 14 27e-mail: [email protected]
NetherlandsArmstrong Building Products B.V.Verkoopkantoor NederlandPostbus 38034800 DV BredaNederlandTel.: (+31) 076 52 30 200Fax: (+31) 076 521 04 07e-mail: [email protected]/plafonds
United KingdomArmstrong World Industries LtdBuilding Products DivisionArmstrong House38 Market Squareuxbridge UB8 1NGTel.: 0800 371849Fax: (+44) 1895 274287e-mail: [email protected]
Republic of IrelandArmstrong World Industries Ltd.108 Greenlea RoadTerenureCo Dublin 6WIrelandTel.: 1800 409002Tel.: (+353) 1 499 1701Fax: (+353) 1 490 7061e mail: [email protected]
MIDDLE EAST /AFRICA / TURKEYArmstrong World Industries LtdAfrica Middle East Turkey DivisionArmstrong House38 Market SquareUxbridge UB8 1NGTel.: (+44) 01895 251122Fax: (+44) 01895 272928e-mail: [email protected]ël: www.armstrong.co.ilSouth Africa: www.armstrong-ceilings.co.za
Dubai | United Arab EmiratesArmstrong World Industries JLTOffice No. 2003, 20th FloorGold Crest Executive TowerJumeirah Lakes TowersP.O. Box 73831Dubai, [email protected]
Tu� rkiyeArmstrong Europa GmbHTu� rkiye Satış TemsilciliğiSarıyer-IstanbulTu� rkiyeGsm: +90 533 367 54 89Fax: +90 212 257 44 [email protected]
CENTRALEUROPE NORTH(DK/EE/FIN/IS/LT/LV/N/PL/S)Armstrong Building Products BVSp. z o.o. Oddział w Polsceul. Domaniewska 3702-672 WarszawaPolandTel.: (+48) 0 22 337 86 10/ 86 11Fax: (+48) 0 22 337 86 12e-mail: [email protected]: www.armstrong.lvLithuania: www.armstrong.ltNorway: www.armstrong.noPoland: www.armstrong.plSweden: www.armstrong.se
CENTRALEUROPE SOUTH(AL/BA/BG/CZ/HR/HU/KO/MD/ME/MK/RO/RS/SK/SI)Armstrong Building ProductsLighthouse Building,Jankovcova 1569/2c,170 00 Praha 7,Czech RepublicTel. : +420 234 700 543e-mail: [email protected] republic: www.armstrong.czHungary: www.armstrong.co.huRomania: www.armstrong.roSerbia: www.armstrong.rsSlovakia: www.armstrong.skSlovenia: www.armstrong.si
EASTERN EUROPECISArmstrong Moscow GmbHPark Place, office E502# 113/1, Leninsky ProspektMoscow 117198RussiaTel.: (+7) 495 956 5100Fax: (+7) 495 956 5101e-mail: [email protected] Federation: www.armstrong.ru
All photographic and design elements supplied in this brochure do not necessarily reflect any recommendation by any of the companies named in this brochureas to the proper use or recommended methods of installation of suspended ceilings and are supplied only as informative material. For technical reasons inprinting, differences may appear between colours printed in this brochure and the actual product. The choice of colours should always be made from a sampleof the product. All statements and technical information contained in this brochure, or any publication of the companies named in this brochure, relating toArmstrong ceilings are based on results obtained under laboratory test conditions. It is the responsibility of the user to verify with the seller of the products inwriting that such statements and information are appropriate to the specific use intended. Sales of the products and liability of the selling companies are inaccordance with the terms and conditions of sale of the selling company. All product specifications are subject to modifications without prior notice.
Advisory note
www.armstrong-ceilings.co.ukwww.armstrong-ceilings.ie
UK Colour Info_Layout 1 15/11/2012 10:39 Page 3