CEI EN 60617-3 (1997) [CEI 3-15]
-
Upload
ruben-dario -
Category
Documents
-
view
176 -
download
21
Embed Size (px)
Transcript of CEI EN 60617-3 (1997) [CEI 3-15]
![Page 1: CEI EN 60617-3 (1997) [CEI 3-15]](https://reader034.fdocuments.net/reader034/viewer/2022042423/55cf9c0e550346d033a86719/html5/thumbnails/1.jpg)
Norma Italiana
N O R M A I T A L I A N A C E I
CNR
CONSIGLIO NAZIONALE DELLE RICERCHE •
AEI
ASSOCIAZIONE ELETTROTECNICA ED ELETTRONICA ITALIANA
Data Pubblicazione
Edizione
Classificazione Fascicolo
COMITATOELETTROTECNICO
ITALIANO
Titolo
Title
CEI EN 60617-3
1997-11
Seconda
3-15 4051
Segni grafici per schemi
Parte 3: Conduttori e dispositivi di connessione
Graphical symbols for diagrams
Part 3: Conductors and connecting devices
ELETTROTECNICA GENERALE E MATERIALI PER USO ELETTRICO
NO
RM
A TE
CNIC
A
![Page 2: CEI EN 60617-3 (1997) [CEI 3-15]](https://reader034.fdocuments.net/reader034/viewer/2022042423/55cf9c0e550346d033a86719/html5/thumbnails/2.jpg)
© CEI - Milano 1997. Riproduzione vietata.
Tutti i diritti sono riservati. Nessuna parte del presente Documento può essere riprodotta o diffusa con un mezzo qualsiasi senza il consenso scritto del CEI.Le Norme CEI sono revisionate, quando necessario, con la pubblicazione sia di nuove edizioni sia di varianti. È importante pertanto che gli utenti delle stesse si accertino di essere in possesso dell’ultima edizione o variante.
SOMMARIO
La presente Parte della Pubblicazione IEC 617 fa parte di una serie che tratta i segni grafici per schemi.Il campo di applicazione ed i riferimenti normativi di tale serie sono indicati nella Pubblicazione
IEC 617-1.
DESCRITTORI
• DESCRIPTORS
Conduttore elettrico •
Electrical conductor;
Schema elettrico •
Electric diagram;
Segno elettrico •
Electrical
symbol;
COLLEGAMENTI/RELAZIONI TRA DOCUMENTI
Nazionali
Europei
(IDT) EN 60617-3:1996-06;
Internazionali
(IDT) IEC 617-3:1996;
Legislativi
INFORMAZIONI EDITORIALI
Norma Italiana
CEI EN 60617-3
Pubblicazione
Norma Tecnica
Carattere Doc.
Stato Edizione
In vigore
Data validità
1998-1-1
Ambito validità
Europeo
Varianti
Nessuna
Ed. Prec. Fasc.
698:1985
Comitato Tecnico
3-Documentazione e segni grafici
Approvata dal
Presidente del CEI
in Data
1997-11-19
CENELEC
in Data
1996-3-5
Sottoposta a
inchiesta pubblica come Documento originale
Chiusa in data
1995-11-15
Gruppo Abb.
1
Sezioni Abb.
A
Prezzo Norma IEC
49 SFr
ICS
01.080.30;
CDU
LEGENDA
(IDT) La Norma in oggetto è identica alle Norme indicate dopo il riferimento (IDT)
![Page 3: CEI EN 60617-3 (1997) [CEI 3-15]](https://reader034.fdocuments.net/reader034/viewer/2022042423/55cf9c0e550346d033a86719/html5/thumbnails/3.jpg)
CENELEC members are bound to comply with theCEN/CENELEC Internal Regulations which stipulatethe conditions for giving this European Standard thestatus of a National Standard without any alteration.Up-to-date lists and bibliographical references con-cerning such National Standards may be obtained onapplication to the Central Secretariat or to anyCENELEC member.This European Standard exists in three official ver-sions (English, French, German).A version in any other language and notified to theCENELEC Central Secretariat has the same status asthe official versions.CENELEC members are the national electrotechnicalcommittees of: Austria, Belgium, Denmark, Finland,France, Germany, Greece, Iceland, Ireland, Italy, Lu-xembourg, Netherlands, Norway, Portugal, Spain,Sweden, Switzerland and United Kingdom.
I Comitati Nazionali membri del CENELEC sono tenu-ti, in accordo col regolamento interno del CEN/CENE-LEC, ad adottare questa Norma Europea, senza alcunamodifica, come Norma Nazionale.Gli elenchi aggiornati e i relativi riferimenti di tali Nor-me Nazionali possono essere ottenuti rivolgendosi alSegretario Centrale del CENELEC o agli uffici di qual-siasi Comitato Nazionale membro.La presente Norma Europea esiste in tre versioni uffi-ciali (inglese, francese, tedesco).Una traduzione effettuata da un altro Paese membro,sotto la sua responsabilità, nella sua lingua nazionalee notificata al CENELEC, ha la medesima validità.I membri del CENELEC sono i Comitati ElettrotecniciNazionali dei seguenti Paesi: Austria, Belgio, Dani-marca, Finlandia, Francia, Germania, Grecia, Irlanda,Islanda, Italia, Lussemburgo, Norvegia, Olanda, Por-togallo, Regno Unito, Spagna, Svezia e Svizzera.
© CENELEC Copyright reserved to all CENELEC members. I diritti di riproduzione di questa Norma Europea sono riservati esclu-sivamente ai membri nazionali del CENELEC.
Comitato Europeo di Normalizzazione Elettrotecnica European Committee for Electrotechnical Standardization
Comité Européen de Normalisation ElectrotechniqueEuropäisches Komitee für Elektrotechnische Normung
C E N E L E C
Secrétariat Central: rue de Stassart 35, B - 1050 Bruxelles
E u r o p ä i s c h e N o r m • N o r m e E u r o p é e n n e • E u r o p e a n S t a n d a r d • N o r m a E u r o p e a
EN 60617-3:1996-06
Segni grafici per schemi
Parte 3: Conduttori e dispositivi di connessione
Graphical symbols for diagrams
Part 3: Conductors and connecting devices
Symboles graphiques pour schémas
Partie 3: Conducteurs et dispositifs de liaison
Graphische Symbole für Schaltpläne
Teil 3: Schaltzeichen für Leiter und Verbinder
![Page 4: CEI EN 60617-3 (1997) [CEI 3-15]](https://reader034.fdocuments.net/reader034/viewer/2022042423/55cf9c0e550346d033a86719/html5/thumbnails/4.jpg)
CONTENTS INDICE
Rif. Topic Argomento Pag
.
NORMA TECNICACEI EN 60617-3:1997-11
Pagina iv
INTRODUZIONE
1
CONDUTTORI E DISPOSITIVI DI CONNESSIONE
3
CONNESSIONI
3
DERIVAZIONI, MORSETTI E COLLEGAMENTI
5
DISPOSITIVI DI CONNESSIONE
7
ACCESSORI PER CAVI
9
SIMBOLI VECCHI
11
DERIVAZIONI, MORSETTI E COLLEGAMENTI
.............
11
DISPOSITIVI DI CONNESSIONE
..........................................
11
INDICE ALFABETICO INGLESE
12
INDICE ALFABETICO ITALIANO
15
INTRODUCTION
P A R T / P A R T E
3
CONDUCTORS AND CONNECTING DEVICES
SECTION/SEZIONE
1
CONNECTIONS
SECTION/SEZIONE
2
JUNCTIONS, TERMINALS AND BRANCHINGS
SECTION/SEZIONE
3
CONNECTION DEVICES
SECTION/SEZIONE
4
CABLE FITTINGS
ANNEX/ALLEGATO
A
OLDER SYMBOLS
Tab. A 1
JUNCTIONS, TERMINALS AND BRANCHINGS
..............
Tab. A 2
CONNECTION DEVICES
...........................................................
ANNEX/ALLEGATO
B
ENGLISH ALPHABETIC INDEX
ANNEX/ALLEGATO
C
ITALIAN ALPHABETIC INDEX
![Page 5: CEI EN 60617-3 (1997) [CEI 3-15]](https://reader034.fdocuments.net/reader034/viewer/2022042423/55cf9c0e550346d033a86719/html5/thumbnails/5.jpg)
NORMA TECNICACEI EN 60617-3:1997-11
Pagina v
FOREWORD
The text of document 3A/381/FDIS, future edi-tion 2 of IEC 617-3, prepared by SC 3A, Graphi-cal symbols for diagrams, of IEC TC 3 Docu-mentation and graphical symbols, wassubmitted to the IEC-CENELEC parallel vote andwas approved by CENELEC as EN 60617-3 on1996/03/05.
The following dates were fixed:
n
latest date by which the EN has to be imple-mented at national level by publication ofan identical national Standard or by en-dorsement
(dop) 1997/02/01
n
latest date by which the national Standardsconflicting with the EN have to be withdrawn
(dow) 1997/02/01
ENDORSEMENT NOTICE
The text of the International StandardIEC 617-3:1996 was approved by CENELEC asa European Standard without any modification.
PREFAZIONE
Il testo del documento 3A/381/FDIS, futura edi-zione 2 della Pubblicazione IEC 617-3, preparatodal Sottocomitato SC 3A della IEC, Graphical sym-bols for diagrams, del CT IEC 3, Documentationand graphical symbols, è stato sottoposto al votoparallelo IEC-CENELEC ed è stato approvato dalCENELEC come Norma Europea EN 60617-3 il5 marzo 1996.
Sono state fissate le date seguenti:
n
data ultima entro la quale la EN deve essereapplicata a livello nazionale mediante pubbli-cazione di una Norma nazionale identica omediante adozione
(dop) 01/02/1997
n
data ultima entro la quale le Norme nazionalicontrastanti con la EN devono essere ritirate
(dow) 01/02/1997
AVVISO DI ADOZIONE
Il testo della Pubblicazione IEC 617-3:1996 è statoapprovato dal CENELEC come Norma Europeasenza alcuna modifica.
![Page 6: CEI EN 60617-3 (1997) [CEI 3-15]](https://reader034.fdocuments.net/reader034/viewer/2022042423/55cf9c0e550346d033a86719/html5/thumbnails/6.jpg)
NORMA TECNICACEI EN 60617-3:1997-11
Pagina vi
![Page 7: CEI EN 60617-3 (1997) [CEI 3-15]](https://reader034.fdocuments.net/reader034/viewer/2022042423/55cf9c0e550346d033a86719/html5/thumbnails/7.jpg)
NORMA TECNICACEI EN 60617-3:1997-11
Pagina 1 di 18
INTRODUCTION
This Part of IEC 617 forms an element of a se-ries which deals with graphical symbols for dia-grams.
The series consists of the following parts:
n
Part 1: General information, general in-dex. Cross-reference tables
n
Part 2: Symbol elements, qualifying sym-bols and other symbols havinggeneral application
n
Part 3: Conductors and connecting de-vices
n
Part 4: Basic passive components
n
Part 5: Semiconductors and electron tubes
n
Part 6: Production and conversion of elec-trical energy
n
Part 7: Switchgear, controlgear and protec-tive devices
n
Part 8: Measuring instruments, lamps andsignalling devices
n
Part 9: Telecommunications: Switchingand peripheral equipment
n
Part 10: Telecommunications: Transmission
n
Part 11: Architectural and topographical in-stallation plans and diagrams
n
Part 12: Binary logic elements
n
Part 13: Analogue elements
The scope and the normative references for thisseries are given in IEC 617-1.
Symbols have been designed in accordancewith requirements given in the future ISO11714-1
(1)
. The module size M = 2,5 mm hasbeen used. For better readability smaller sym-bols in this standard have been enlarged todouble size and are marked “200%” in thesymbol column. To save space larger symbolshave been reduced to half size and are marked“50%” in the symbol column. In accordancewith the future ISO 11714-1, clause 7, symboldimensions (for instance height) may be modi-fied in order to make space for greater numberof terminals or for other layout requirements.In all cases, whether the size is enlarged or re-duced, or dimensions modified, the thicknessof the original line should be maintained with-out scaling.
The symbols in this standard are laid out insuch a way that the distance between connect-ing lines is a multiple of a certain module. Themodule 2M has been chosen to provideenough space for a required terminal designa-tion. The symbols have been drawn to a sizeconvenient for comprehension, using the samegrid consistently in the representation of allsymbols.
(1) At present, at the stage of Draft International Standard (document3/563/DIS).
INTRODUZIONE
La presente Parte della Pubblicazione IEC 617 faparte di una serie che tratta i segni grafici perschemi.
Tale serie comprende le parti seguenti:
n
Parte 1: Generalità - Indice generale - Ta-belle di corrispondenza
n
Parte 2: Elementi dei segni grafici, segnigrafici distintivi ed altri segni di usogenerale
n
Parte 3: Conduttori e dispositivi di connes-sione
n
Parte 4: Componenti passivi
n
Parte 5: Semiconduttori e tubi elettronici
n
Parte 6: Produzione, trasformazione e con-versione dell’energia elettrica
n
Parte 7: Apparecchiature e dispositivi di co-mando e di protezione
n
Parte 8: Strumenti di misura, lampade e di-spositivi di segnalazione
n
Parte 9: Telecomunicazioni: apparecchia-ture di commutazione e periferiche
n
Parte 10: Telecomunicazioni: trasmissione
n
Parte 11: Schemi e piani di installazione ar-chitettonici e topografici
n Parte 12: Elementi logici binarin Parte 13: Elementi analogici
Il campo di applicazione e i riferimenti normativi ditale serie sono indicati nella Pubblicazione IEC 617-1.
I segni grafici sono stati concepiti in conformità con lenorme indicate nella norma futura ISO 11714-1(1). È sta-ta utilizzata la dimensione del modulo M = 2,5 mm.Nella presente norma, per migliorare la lettura, la di-mensione dei segni grafici più piccoli è stata raddoppia-ta e i segni grafici sono stati marcati “200%” nella colon-na segno grafico. Per guadagnare spazio, la dimensionedei segni più grandi è stata dimezzata e i segni graficisono stati marcati “50%” nella colonna segno grafico. Inconformità con la norma futura ISO 11714-1, articolo 7,è possibile modificare le dimensioni di un segno grafi-co (ad esempio l’altezza) per guadagnare spazio ed ag-giungere un maggior numero di morsetti o per esigen-ze di impaginazione. In ogni caso, a prescindere che sitratti di riduzione o di ingrandimento o di modificadelle dimensioni, si deve mantenere lo spessore origi-nale del segno grafico senza cambiare la scala.
I segni grafici della presente norma sono stati pre-sentati in modo tale che la distanza tra i tratti diconnessione sia un multiplo di un certo modulo.Il modulo 2M è stato scelto per riservare unospazio sufficiente all’identificazione necessaria deimorsetti. I segni grafici sono stati disegnati secon-do una misura idonea alla comprensione e utiliz-zando sempre la stessa griglia per la rappresen-tazione di tutti i segni grafici.
(1) Attualmente è allo stadio di Bozza di Norma Internazionale (documento3/563/DIS).
CEI EN 60617-3:1997-11
24
![Page 8: CEI EN 60617-3 (1997) [CEI 3-15]](https://reader034.fdocuments.net/reader034/viewer/2022042423/55cf9c0e550346d033a86719/html5/thumbnails/8.jpg)
NORMA TECNICACEI EN 60617-3:1997-11Pagina 2 di 18
Tutti i segni grafici sono stati elaborati all’internodi una griglia con un sistema di elaborazione as-sistita dal calcolatore. La griglia utilizzata è statariprodotta sullo sfondo dei segni.
I simboli più vecchi che hanno fatto parte dell’ap-pendice A della prima edizione della Pubblica-zione IEC 617-3 per un periodo transitorio nonfanno più parte di questa seconda edizionepoichè saranno ritirati definitivamente dall’uso.
Gli indici delle Appendici B e C contengono unelenco alfabetico dei nomi dei segni grafici e deiloro numeri corrispondenti. I nomi dei segnigrafici si basano sulla descrizione dei segni graficidella presente parte. La Pubblicazione IEC 617-1contiene un indice generale con un elenco alfa-betico dei segni grafici di tutte le parti.
All symbols are designed within a grid in acomputer-aided draughting system. The gridwhich was used has been reproduced in thebackground of the symbols.
The older symbols which were included in ap-pendix A of the first edition of IEC 617-3 for atransitional period, are no longer part of thissecond edition, as they will definitely be with-drawn from use.
The indexes in Annex B and C include an al-phabetic list of symbol names and their corre-sponding number. The symbol names arebased on the description of the symbols of thispart. A general index including an alphabeticlist of symbols of all parts is given inIEC 617-1.
![Page 9: CEI EN 60617-3 (1997) [CEI 3-15]](https://reader034.fdocuments.net/reader034/viewer/2022042423/55cf9c0e550346d033a86719/html5/thumbnails/9.jpg)
NORMA TECNICACEI EN 60617-3:1997-11
Pagina 3 di 18
SEGNI GRAFICI PER SCHEMI
CONDUTTORI E DISPOSITIVI DI CONNESSIONE
CONNESSIONI
GRAPHICAL SYMBOLS FOR DIAGRAMS
P A R T / P A R T E
3 CONDUCTORS AND CONNECTING DEVICES
SECTION/SEZIONE
1 CONNECTIONS
N. Segno grafico Symbol Descrizione Description
03-01-01 ConduttoreGruppo di conduttori
ESEMPI:n conduttoren cavon linean linea di propagazione
Se un tratto unico rappresenta ungruppo di conduttori, il numero deiconduttori può essere indicato o dapiù tratti obliqui, o da un solotratto obliquo completo di cifrarelativa al numero dei conduttori.La lunghezza del segno grafico delconduttore può essere adattata secon-do la disposizione dello schema
ConnectionGroup of connections
EXAMPLES:n conductorn cablen linen transmission path
If a single line represents a groupof conductors, the number of con-nections may be indicated eitherby adding as many oblique strokesor one stroke followed by the fig-ure for the number of connections.The length of the connectionsymbol may be adjusted to thelayout of the diagram
03-01-02
03-01-03
ESEMPI:Tre conduttoriAltre informazioni potranno essereaggiunte come segue:n natura della correnten sistema di distribuzionen frequenzan tensionen numero dei conduttorin sezione di ciascun condut-
toren simbolo chimico del materiale
del conduttore
Il numero dei conduttori è seguitodalla sezione, separato da x.
Se si usano conduttori con sezionediversa dai primi, il loro numero esezione saranno preceduti dal se-gno +
EXAMPLES:Three connectionsAdditional information may be in-dicated such as:n kind of currentn system of distributionn frequencyn voltagen number of conductorsn cross-sectional area of each
conductorn the chemical symbol for the
conductor material
The number of conductors is fol-lowed by the sectional area, sepa-rated by x. If different sizes are used, theirparticulars should be separatedby +
03-01-04 ESEMPI:Circuito a corrente continua 110 V,due conduttori da 120 mm2 di al-luminio
EXAMPLES:Direct current circuit, 110 V, twoaluminium conductors of 120 mm2
03-01-05 Circuito trifase, 50 Hz, 400 V, treconduttori da 120 mm2, conneutro da 50 mm2 3N può essere sostituito da 3+N
Three-phase circuit, 50 Hz, 400 V,three conductors of 120 mm2, withneutral of 50 mm2
3N may be replaced by 3+N
Forma 1Form 1
Forma 2Form 2
![Page 10: CEI EN 60617-3 (1997) [CEI 3-15]](https://reader034.fdocuments.net/reader034/viewer/2022042423/55cf9c0e550346d033a86719/html5/thumbnails/10.jpg)
NORMA TECNICACEI EN 60617-3:1997-11Pagina 4 di 18
03-01-06 Connessione flessibile Flexible connection
03-01-07 Conduttore schermatoSe parecchi conduttori costitui-scono un cavo o sono schermati ocordati insieme, si può utilizzare ilmetodo di rappresentazione03-01-10 ma i segni di questi con-duttori sono aggiunti con quelli dialtri conduttori.Il segno grafico dei conduttoricostituenti un cavo o cordati oschermati insieme verrà rappre-sentato sopra, sotto o di fianco algruppo in cui vi sono i segni deiconduttori. Tale segno grafico saràcollegato da un tratto che conduceai tratti individuali che rappresen-tano i conduttori costituenti uncavo o cordati o schermati
Screened conductorThe drawing method shown in03-01-10 may be used if severalconductors are contained within thesame screen or cable or are twistedtogether, but the symbols for theseconductors are intermingled withsymbols for other connections.The symbol for cable, screen, ortwist shall be shown, either above,below, or beside the intermingledgroup of conductor symbols. Itshall be connected by a leaderline pointing to the individuallines representing the conductorswithin the same screen, cable ortwisted group
03-01-08 Connessione cordataDue connessioni, esempioVedi regole di applicazione delsegno grafico 03-01-07
Twisted connectionTwo connections shownThe rule with 03-01-07 applies
03-01-09 Conduttori in cavo, esempio di treconduttoriVedi regole di applicazione delsegno grafico 03-01-07
Conductors in a cable, three con-ductors shownThe rule with 03-01-07 applies
03-01-10 ESEMPIO:Cinque conduttori, dei quali duefanno parte dello stesso cavo, in-dicati con le frecce
EXAMPLE:Five conductors, two of whichmarked by arrowheads are in onecable
03-01-11 Coppia coassialeSe la struttura coassiale non pro-segue, il tratto tangente deve es-sere rappresentato solamente sullaparte coassiale
Coaxial pairIf the coaxial structure is not main-tained, the tangential line shall bedrawn only on the coaxial side.
03-01-12 ESEMPIO:Coppia coassiale collegata ai mor-setti
EXAMPLE:Coaxial pair connected to termi-nals
N. Segno grafico Symbol Descrizione Description
![Page 11: CEI EN 60617-3 (1997) [CEI 3-15]](https://reader034.fdocuments.net/reader034/viewer/2022042423/55cf9c0e550346d033a86719/html5/thumbnails/11.jpg)
NORMA TECNICACEI EN 60617-3:1997-11
Pagina 5 di 18
DERIVAZIONI, MORSETTI E COLLEGAMENTISECTION/SEZIONE
2 JUNCTIONS, TERMINALS AND BRANCHINGS
03-01-13 Coppia coassiale schermata Coaxial pair with screen
03-01-14 Estremità di un conduttore o di uncavo, non collegata
End of a conductor or cable notconnected
03-01-15 Estremità di un conduttore o di uncavo, non collegata e apposita-mente isolata
End of a conductor or cable notconnected and specially insulated
N. Segno grafico Symbol Descrizione Description
03-02-01 DerivazionePunto di connessione
JunctionConnection point
03-02-02 Morsetto Terminal
03-02-03 MorsettieraSi può aggiungere la numerazionedei morsetti
Terminal stripTerminal markings may be added
03-02-04 Connessione a T T-connection
03-02-05 Il segno grafico 03-02-04 è rappre-sentato con il segno grafico di de-rivazione.
Symbol 03-02-04 shown with junc-tion symbol.
03-02-06 Doppia connessione di conduttori Double junction of conductors
03-02-07 La Forma 2 verrà usata solo permotivi di presentazione
Form 2 shall only be used if re-quired by layout considerations.
03-02-08 cancellatodeleted
Trasferito nell’Appendice A: 03-A1-01 Transferred to Annex A: 03-A1-01
N. Segno grafico Symbol Descrizione Description
Forma 1Form 1
Forma 2Form 2
Forma 1Form 1
Forma 2Form 2
![Page 12: CEI EN 60617-3 (1997) [CEI 3-15]](https://reader034.fdocuments.net/reader034/viewer/2022042423/55cf9c0e550346d033a86719/html5/thumbnails/12.jpg)
NORMA TECNICACEI EN 60617-3:1997-11Pagina 6 di 18
03-02-09 CollegamentoDerivazione comune a un gruppodi circuiti paralleli identici e ri-petuti.“n” sarà sostituito dal numero to-tale dei circuiti. Il numero verràposta a lato del segno grafico diderivazione. Vedere Pubblica-zione IEC 1082-2. Una coppia disegni grafici a specchio indical’estensione del(dei) circuito(i).Rappresentazione del concetto: 10 resistenze identiche in parallelo
BranchingJunction common to a group ofidentical and repeated parallel cir-cuits.“n” shall be replaced by the totalnumber of circuits. The figureshall be placed adjacent to thejunction symbol. See IEC 1082-2.A pair of mirror-imaged symbolsindicates the extent of the cir-cuit(s).Illustration of concept: 10 parallel and identical resistors
03-02-10 cancellatodeleted
Trasferito nell’Appendice A: 03-A1-02 Transferred to Annex A: 03-A1-02
03-02-11 Trasposizione di conduttoriCambio della sequenza della faseInversione di polaritàIl segno grafico si applica ai circui-ti multi-fase o di potenza in cor-rente continuaSi può indicare la permutazione diconduttori
Interchange of conductorsChange of phase sequenceInversion of polarityThe symbol applies to multi-phaseor DC power circuitsThe interchanged conductors maybe indicated.
03-02-12 ESEMPIO:Cambio della sequenza di fase
EXAMPLE:Change of phase sequence
03-02-13 Punto neutroPunto in cui i conduttori multiplisono collegati insieme per formareil punto neutro di un sistemapolifase
Neutral pointPoint at which multiple conduc-tors are connected together toform the neutral point in a mul-tiphase system
03-02-14 ESEMPI:Alternatore trifase, sincrono
Alternatore trifase, con entrambele estremità di ogni fase portateall’esterno e con punto neutroesterno
(Continua sul retro)
EXAMPLES:Three-phase synchronous genera-torSynchronous generator, three-phase,both leads of each phase of thegenerator winding brought out,shown with external neutral point
(Continued overleaf)
N. Segno grafico Symbol Descrizione Description
![Page 13: CEI EN 60617-3 (1997) [CEI 3-15]](https://reader034.fdocuments.net/reader034/viewer/2022042423/55cf9c0e550346d033a86719/html5/thumbnails/13.jpg)
NORMA TECNICACEI EN 60617-3:1997-11
Pagina 7 di 18
DISPOSITIVI DI CONNESSIONESECTION/SEZIONE
3 CONNECTION DEVICES
03-02-15 Il segno grafico 03-02-14 è illu-strato in rappresentazione multifi-lare
Symbol 03-02-14 shown inmulti-line representation
03-02-16 Presa del conduttore che non in-terrompe il conduttoreIl segno grafico è rappresentatocon il segno grafico 03-02-04.Il tratto deve essere disegnato pa-rallelamente al segno grafico delconduttore non interrotto non in-terrotto
Conductor tap not interrupting theconductorThe symbol is shown with symbol03-02-04.The stroke shall be drawn parallel tothe symbol for the non-interruptedconductor
03-02-17 Derivazione che richiede un uten-sile specialeIl segno grafico è illustrato con ilsegno grafico 03-02-04
Junction requiring a special tool
The symbol is shown with symbol03-02-04
N. Segno grafico Symbol Descrizione Description
03-03-01 Contatto femmina (presa o spina)PresaIn rappresentazione unifilare ilsegno grafico denota la femminadi un connettore multicontatto
Female contact (of a socket or plug) SocketIn single line representation thesymbol denotes the female part ofa multi-contact connector
03-03-02 cancellatodeleted
Trasferito all’Appendice A: 03-A2-01 Transferred to Annex A: 03-A2-01
03-03-03 Contatto maschio (presa o spina)SpinaIn rappresentazione unifilare ilsegno grafico denota la femminadi un connettore multicontatto
Male contact (of a socket or plug)PlugIn single line representation thesymbol denotes the male part of amulti-contact connector
03-03-04 cancellatodeleted
Trasferito all’Appendice A: 03-A2-02 Transferred to Annex A: 03-A2-02
03-03-05 Presa e spinaVedi regole di applicazione deisegni grafici 03-03-01 e 03-03-03
Plug and socketThe rules in symbol 03-03-01 and03-03-03 apply
03-03-06 cancellatodeleted
Trasferito all’Appendice A: 03-A2-03 Transferred to Annex A: 03-A2-03
N. Segno grafico Symbol Descrizione Description
![Page 14: CEI EN 60617-3 (1997) [CEI 3-15]](https://reader034.fdocuments.net/reader034/viewer/2022042423/55cf9c0e550346d033a86719/html5/thumbnails/14.jpg)
NORMA TECNICACEI EN 60617-3:1997-11Pagina 8 di 18
03-03-07 Presa e spina, multipolariIl segno grafico è rappresentatocon presa e spina esapolari in rap-presentazione multifilare
Socket and plug, multipoleThe symbol is shown with six fe-male and six male contacts inmulti-line representation
03-03-08 Presa e spina multipolariPresa e spina esapolari in rappre-sentazione unifilare
Socket and plug, multipoleThe symbol represents insingle-line representation six fe-male and six male contacts
03-03-09 Connettore, parte fissa
Questo segno grafico si deve im-piegare unicamente quando si de-sidera distinguere la parte fissadalla parte mobile di un connet-tore
Connector, fixed portion of an as-semblyThe symbol should be used onlywhen it is desired to distinguishbetween the fixed and movableparts in a connector assembly
03-03-10 Connettore, parte mobile
Vedere nota del segno grafico03-03-09
Connector, movable portion of anassemblyThe rule with symbol 03-03-09 ap-plies
03-03-11 Connettore assiematoIl segno grafico è rappresentatocon spina fissa e presa mobile ac-coppiateVedi regole di applicazione delsegno grafico 03-03-09
Connector assemblyThe symbol is shown with fixedplug-side and movable socket-side.The rule with symbol 03-03-09 ap-plies
03-03-12 Spina e presa (jack) bipolare, tipotelefonico
Il polo più lungo rappresental’estremità della spina, il polo piùcorto il corpo della spina
Telephone type plug and jack The symbol is shown with twopolesThe longest pole on the plug sym-bol represents the tip of the plug,and the shortest the sleeve.
03-03-13 Spina e presa (jack) tripolare, tipotelefonico (jack con contatti diapertura)
Vedi regole di applicazione delsegno grafico 03-03-12
Telephone type plug and jackwith break contacts The symbol is shown with threepolesThe rule with symbol 03-03-12 ap-plies
03-03-14 Jack di interruzione o di separa-zione, tipo telefonico
Telephone type break jackTelephone type isolating jack
03-03-15 Presa e spina coassialiSe la presa o la spina coassiale èconnessa a una coppia coassiale, iltratto tangente deve essere prolun-gato in maniera appropriata
Coaxial plug and socketIf the coaxial plug or socket isconnected to a coaxial pair, thetangential stroke shall be extend-ed on the appropriate side
N. Segno grafico Symbol Descrizione Description
![Page 15: CEI EN 60617-3 (1997) [CEI 3-15]](https://reader034.fdocuments.net/reader034/viewer/2022042423/55cf9c0e550346d033a86719/html5/thumbnails/15.jpg)
NORMA TECNICACEI EN 60617-3:1997-11
Pagina 9 di 18
ACCESSORI PER CAVISECTION/SEZIONE
4 CABLE FITTINGS
03-03-16 Connettore d’estremità a pressione Butt-connector
03-03-17 Piastrina di connessione, chiusa Connecting link, closed
03-03-18
03-03-19 Piastrina di connessione, aperta Connecting link, open
03-03-20 Connettore a presa e spinamaschio-maschio(ponticello)
Plug and socket-type connector,for example U-link:male-male
03-03-21 maschio-femmina male-female
03-03-22 maschio-maschio con presa di de-rivazione
male-male with socket access
N. Segno grafico Symbol Descrizione Description
03-04-01 Terminazione (rappresentata conun cavo tripolare)
Cable sealing end, shown withone three-core cable
03-04-02 Terminazione (rappresentata contre cavi unipolari)
Cable sealing end, shown withthree one-core cables
03-04-03 Cassetta di giunzione per cavi (nelcaso di tre conduttori):rappresentazione multifilare
Straight-through joint box, shownwith three conductors:multi-line representation
03-04-04 rappresentazione unifilare single-line representation
N. Segno grafico Symbol Descrizione Description
Forma 1Form 1
Forma 2Form 2
![Page 16: CEI EN 60617-3 (1997) [CEI 3-15]](https://reader034.fdocuments.net/reader034/viewer/2022042423/55cf9c0e550346d033a86719/html5/thumbnails/16.jpg)
NORMA TECNICACEI EN 60617-3:1997-11Pagina 10 di 18
03-04-05 Cassetta di derivazione per cavi(esempio: tre conduttori con de-rivazione:rappresentazione multifilare
Junction box, shown with threeconductors with T-connections:multi-line representation
03-04-06 rappresentazione unifilare single-line representation
03-04-07 Dispositivo di passaggio di cavi atenuta di pressione (nel caso di trecavi).Il lato dove la pressione è più ele-vata è la base maggiore del trape-zio, da ritenersi perciò la parte ditenuta
Pressure-tight bulkhead cablegland, shown with three cables.
The high pressure side is the long-er side of the trapezium thus re-taining gland in bulk-head
N. Segno grafico Symbol Descrizione Description
![Page 17: CEI EN 60617-3 (1997) [CEI 3-15]](https://reader034.fdocuments.net/reader034/viewer/2022042423/55cf9c0e550346d033a86719/html5/thumbnails/17.jpg)
NORMA TECNICACEI EN 60617-3:1997-11
Pagina 11 di 18
SIMBOLI VECCHI
La presente appendice contiene i segni graficinormalizzati della Pubblicazione IEC 617-3 (1983)che sono stati cancellati. Sono rappresentati qui diseguito soltanto per facilitare la comprensione deivecchi schemi.
(Nella presente appendice, i numeri della Pubbli-cazione del 1983 sono tra parentesi).
DERIVAZIONI, MORSETTI E COLLEGAMENTI
DISPOSITIVI DI CONNESSIONE
ANNEX/ALLEGATO
A OLDER SYMBOLS
This annex contains symbols standardized inIEC 617-3 (1983), which are now deleted. Theyare shown here for information purposes onlyto facilitate the comprehension of older dia-grams.
(In this annex the numbering from 1983-editionis quoted in parentheses.)
Tab. A 1 JUNCTIONS, TERMINALS AND BRANCHINGS
Tab. A 2 CONNECTION DEVICES
N. Segno grafico Symbol Descrizione Description
03-A1-01
(03-02-08)
Giunzione di conduttore Conductor jointIn-line splice
03-A1-02
(03-02-10)
Il numero totale di apparecchisimilari può essere precisato scri-vendo una cifra a lato del segnografico di connessione comune
ESEMPIO:Banco di 10 selettori multipli
The total number of similar itemsmay be indicated by a figure nearthe common connection symbol
EXAMPLE:Multipled uniselector banksshown for 10 banks
N. Segno grafico Symbol Descrizione Description
03-A2-01(03-03-02)
Presa o spina (femmina)PresaIn rappresentazione unifilare ilsegno grafico denota la femminadi un connettore multi-contatto
Female contact (of a socket or plug) SocketIn single line representation thesymbol denotes the female part ofa multi-contact connector
03-A2-02(03-03-04)
Presa o spina (maschio)PresaIn rappresentazione unifilare ilsegno grafico denota la parte mas-chio di un connettore multi-con-tatto
Male contact (of a socket or plug) PlugIn single line representation thesymbol denotes the male part of amulti-contact connector
03-A2-03(03-03-06)
Presa e spinaVedere note dei segni grafici03-03-01 e 03-03-03
Plug and socketThe rules in symboles 03-03-01and 03-03-03 apply
informativeinformativo
![Page 18: CEI EN 60617-3 (1997) [CEI 3-15]](https://reader034.fdocuments.net/reader034/viewer/2022042423/55cf9c0e550346d033a86719/html5/thumbnails/18.jpg)
NORMA TECNICACEI EN 60617-3:1997-11Pagina 12 di 18
INDICE ALFABETICO INGLESE
Branching ................................................................................................................................... 03-02-09
Break jack, telephone type........................................................................................................ 03-03-14
Bulkhead cable gland ................................................................................................................ 03-04-07
Bus bar........................................................................................................................................ 03-01-08
Butt-connector............................................................................................................................ 03-03-16
Cable........................................................................................................................................... 03-01-01
Cable fitting, cable sealing end, one three-core cable............................................................. 03-04-01
Cable fitting, junction box ......................................................................................................... 03-04-05
Cable fitting, junction box, single-line representation ............................................................. 03-04-06
Cable fitting, sealing end, three one-core cables ..................................................................... 03-04-02
Cable fitting, straight-through joint box.................................................................................... 03-04-03
Cable fitting, straight-through joint box, single-line representation........................................ 03-04-05
Cable fittings, pressure-tight bulkhead cable gland................................................................. 03-04-07
Cable gland................................................................................................................................. 03-04-07
Cable sealing end, one three-core cable .................................................................................. 03-04-01
Cable sealing end, three one-core cables................................................................................. 03-04-02
Cable, not connected ................................................................................................................. 03-01-14
Cable, not connected and specially insulated .......................................................................... 03-01-15
Cable-conductor ......................................................................................................................... 03-01-09
Change of phase sequence ....................................................................................................... 03-02-11
Circuit.......................................................................................................................................... 03-01-05
Coaxial cable .............................................................................................................................. 03-01-11
Coaxial pair with screen ............................................................................................................ 03-01-13
Coaxial pair, connected to terminals ........................................................................................ 03-01-12
Coaxial pair, general symbol ..................................................................................................... 03-01-11
Coaxial plug and socket ............................................................................................................ 03-03-15
Conductor ................................................................................................................................... 03-01-01
Conductor in a cable,................................................................................................................. 03-01-09
Conductor tap not interrupting ................................................................................................. 03-02-16
Conductor, flexible connection ................................................................................................. 03-01-06
Conductor, not connected ......................................................................................................... 03-01-14
Conductor, not connected and specially insulated .................................................................. 03-01-15
Conductor, twisted connection.................................................................................................. 03-01-08
Conductors, group of................................................................................................................. 03-01-01
Connection device ..................................................................................................................... 03-03-01
Connecting device, plug............................................................................................................ 03-03-03
Connecting device, socket......................................................................................................... 03-03-01
Connecting link, closed ............................................................................................................. 03-03-17
Connecting link, open ............................................................................................................... 03-03-19
Connection ................................................................................................................................. 03-01-01
Connection device, butt-connector ........................................................................................... 03-03-17
Connection device, plug and socket-type connector, male-female ........................................ 03-03-21
Connection device, socket and plug......................................................................................... 03-03-05
Connection device, socket and plug, multipole....................................................................... 03-03-07
Connection device, socket and plug, multipole, in single-line representation ...................... 03-03-08
Connection devices, plug and socket-type connector, male-male.......................................... 03-03-20
Connection devices, plug and socket-type connector, male-male with socket access .......... 03-03-22
Connection of conductor, T-connection, connection point..................................................... 03-02-04
Connection of conductor, T-connection, junction ................................................................... 03-02-05
ANNEX/ALLEGATO
B ENGLISH ALPHABETIC INDEXinformativeinformativo
![Page 19: CEI EN 60617-3 (1997) [CEI 3-15]](https://reader034.fdocuments.net/reader034/viewer/2022042423/55cf9c0e550346d033a86719/html5/thumbnails/19.jpg)
NORMA TECNICACEI EN 60617-3:1997-11
Pagina 13 di 18
Connection of conductor, branching ........................................................................................ 03-02-09
Connection of conductor, change of phase sequence............................................................. 03-02-11
Connection of conductor, conductor tap not interrupting the conductor .............................. 03-02-16
Connection of conductor, connection....................................................................................... 03-02-01
Connection of conductor, connection point............................................................................. 03-02-01
Connection of conductor, double junction of conductors....................................................... 03-02-06
Connection of conductor, interchange of conductors.............................................................. 03-02-11
Connection of conductor, inversion of polarity ....................................................................... 03-02-11
Connection of conductor, junction............................................................................................ 03-02-01
Connection of conductor, junction requiring a special tool .................................................... 03-02-17
Connection of conductor, neutral point in a multiphase system ............................................ 03-02-13
Connection of conductor, neutral point, three-phase synchronous generator....................... 03-02-14
Connection of conductor, neutral point, three-phase synchronous generator shown in multi-line representation................................................................................................. 03-02-15
Connection of conductor, terminal ........................................................................................... 03-02-02
Connection of conductor, terminal strip ................................................................................... 03-02-03
Connection point........................................................................................................................ 03-02-01
Connection point........................................................................................................................ 03-02-01
Connector assembly................................................................................................................... 03-03-11
Connector, fixed portion of an assembly.................................................................................. 03-03-09
Connector, movable portion of an assembly............................................................................ 03-03-10
Double junction of conductors.................................................................................................. 03-02-06
Female contact ........................................................................................................................... 03-03-01
Female contact of a plug ........................................................................................................... 03-03-01
Female contact of a socket ........................................................................................................ 03-03-01
Female contact, female part of a multi-contact connector ...................................................... 03-03-01
Female part of a multi-contact connector................................................................................. 03-03-01
Flexible connection.................................................................................................................... 03-01-06
Gland .......................................................................................................................................... 03-04-07
Group of conductors.................................................................................................................. 03-01-01
Group of connections ................................................................................................................ 03-01-01
Interchange of conductors......................................................................................................... 03-02-11
Inversion of polarity................................................................................................................... 03-02-11
Isolating jack, telephone type ................................................................................................... 03-03-14
Jack ............................................................................................................................................. 03-03-14
Joint box, straight-through......................................................................................................... 03-04-03
Joint box, straight-through, single-line representation............................................................. 03-04-04
Jump joint ................................................................................................................................... 03-03-17
Junction....................................................................................................................................... 03-02-01
Junction box ............................................................................................................................... 03-04-05
Junction box, single-line representation ................................................................................... 03-04-06
Junction requiring a special tool ............................................................................................... 03-02-17
Line ............................................................................................................................................. 03-01-01
Link ............................................................................................................................................. 03-03-17
Male contact ............................................................................................................................... 03-03-03
Male contact of a plug ............................................................................................................... 03-03-03
Male contact of a socket ............................................................................................................ 03-03-03
Male contact, male part of a multi-contact connector ............................................................. 03-03-03
Male part of a multi-contact connector..................................................................................... 03-03-03
Neutral point in a multiphase system ....................................................................................... 03-02-13
Neutral point, three-phase synchronous generator.................................................................. 03-02-14
Plug ............................................................................................................................................. 03-03-03
![Page 20: CEI EN 60617-3 (1997) [CEI 3-15]](https://reader034.fdocuments.net/reader034/viewer/2022042423/55cf9c0e550346d033a86719/html5/thumbnails/20.jpg)
NORMA TECNICACEI EN 60617-3:1997-11Pagina 14 di 18
Plug and jack with break contacts, telephone type................................................................. 03-03-13
Plug and jack, telephone type................................................................................................... 03-03-12
Plug and socket.......................................................................................................................... 03-03-05
Plug and socket male-female .................................................................................................... 03-03-21
Plug and socket male-male ....................................................................................................... 03-03-20
Plug and socket male-male with socket access........................................................................ 03-03-22
Plug and socket, coaxial ............................................................................................................ 03-03-15
Pressure-tight bulkhead cable gland......................................................................................... 03-04-07
Screened conductor ................................................................................................................... 03-01-07
Sealing end ................................................................................................................................. 03-04-01
Socket ......................................................................................................................................... 03-03-01
Socket and plug ......................................................................................................................... 03-03-05
Socket and plug, coaxial............................................................................................................ 03-03-15
Socket and plug, multipole ....................................................................................................... 03-03-07
Socket and plug, multipole, single-line representation ........................................................... 03-03-08
Straight-through joint box.......................................................................................................... 03-04-03
Straight-through joint box, single-line representation.............................................................. 03-04-04
T-connection, connection point ................................................................................................ 03-02-04
T-connection, junction............................................................................................................... 03-02-05
Telephone type break jack........................................................................................................ 03-03-14
Telephone type isolating jack ................................................................................................... 03-03-14
Telephone type plug and jack ................................................................................................. 03-03-12
Telephone type plug and jack with break contacts................................................................. 03-03-13
Terminal...................................................................................................................................... 03-02-02
Terminal strip ............................................................................................................................. 03-02-03
Transmission path ...................................................................................................................... 03-01-01
Twisted connection.................................................................................................................... 03-01-08
U-link .......................................................................................................................................... 03-03-20
Wire ............................................................................................................................................ 03-01-11
![Page 21: CEI EN 60617-3 (1997) [CEI 3-15]](https://reader034.fdocuments.net/reader034/viewer/2022042423/55cf9c0e550346d033a86719/html5/thumbnails/21.jpg)
NORMA TECNICACEI EN 60617-3:1997-11
Pagina 15 di 18
INDICE ALFABETICO ITALIANO
Accessorio per cavo, cassetta di derivazione per cavi ............................................................. 03-04-05
Accessorio per cavo, cassetta di derivazione per cavi, rappresentazione unifilare................ 03-04-06
Accessorio per cavo, cassetta di giunzione per cavi................................................................ 03-04-03
Accessorio per cavo, cassetta di giunzione per cavi, rappresentazione unifilare .................. 03-04-05
Accessorio per cavo, dispositivo di passaggio di cavi a tenuta di pressione ......................... 03-04-07
Accessorio per cavo, terminazione con tre cavi unipolari....................................................... 03-04-02
Accessorio per cavo, terminazione con un cavo tripolare ...................................................... 03-04-01
Cambio della sequenza della fase............................................................................................. 03-02-11
Cassetta di derivazione per cavi................................................................................................ 03-04-05
Cassetta di derivazione per cavi, rappresentazione unifilare .................................................. 03-04-06
Cassetta di giunzione per cavi................................................................................................... 03-04-03
Cassetta di giunzione per cavi, rappresentazione unifilare ..................................................... 03-04-04
Cavo ............................................................................................................................................ 03-01-01
Cavo coassiale ............................................................................................................................ 03-01-11
Cavo, non collegato ................................................................................................................... 03-01-14
Cavo, non collegato e appositamente isolato........................................................................... 03-01-15
Circuito ....................................................................................................................................... 03-01-05
Collegamento.............................................................................................................................. 03-02-09
Conduttore.................................................................................................................................. 03-01-01
Conduttori in cavo ..................................................................................................................... 03-01-09
Conduttore schermato................................................................................................................ 03-01-07
Conduttore, non collegato......................................................................................................... 03-01-14
Conduttore, non collegato e appositamente isolato ................................................................ 03-01-15
Conduttori o cavi cordati ........................................................................................................... 03-01-08
Conduttori, gruppo di ................................................................................................................ 03-01-01
Connessione a T, derivazione.................................................................................................... 03-02-05
Connessione a T, punto di connessione................................................................................... 03-02-04
Connessione cordata.................................................................................................................. 03-01-08
Connessione di conduttore, cambio della sequenza della fase............................................... 03-02-11
Connessione di conduttore, collegamento ............................................................................... 03-02-09
Connessione di conduttore, connessione ................................................................................. 03-02-01
Connessione di conduttore, connessione a T, derivazione ..................................................... 03-02-05
Connessione di conduttore, connessione a T, punto di connessione..................................... 03-02-04
Connessione di conduttore, derivazione .................................................................................. 03-02-01
Connessione di conduttore, doppia derivazione ..................................................................... 03-02-06
Connessione di conduttore, inversione di polarità .................................................................. 03-02-11
Connessione di conduttore, morsettiera ................................................................................... 03-02-03
Connessione di conduttore, morsetto ....................................................................................... 03-02-02
Connessione di conduttore, presa del conduttore che non interrompe il conduttore .......... 03-02-16
Connessione di conduttore, punto neutro di un sistema polifase .......................................... 03-02-13
Connessione di conduttore, punto neutro, alternatore trifase................................................. 03-02-14
Connessione di conduttore, punto neutro, alternatore trifase in rappresentazione multifilare ............................................................................................................................. 03-02-15
Connessione di conduttore, trasposizione di conduttori ......................................................... 03-02-11
Connessione flessibile................................................................................................................ 03-01-06
Connettore a presa e spina maschio-maschio (ponticello) ..................................................... 03-03-20
Connettore assiemato................................................................................................................. 03-03-11
Connettore d’estremità a pressione........................................................................................... 03-03-16
Connettore, parte fissa ............................................................................................................... 03-03-09
ANNEX/ALLEGATO
C ITALIAN ALPHABETIC INDEXinformativeinformativo
![Page 22: CEI EN 60617-3 (1997) [CEI 3-15]](https://reader034.fdocuments.net/reader034/viewer/2022042423/55cf9c0e550346d033a86719/html5/thumbnails/22.jpg)
NORMA TECNICACEI EN 60617-3:1997-11Pagina 16 di 18
Connettore, parte mobile........................................................................................................... 03-03-10
Contatto femmina (presa o spina) ............................................................................................ 03-03-01
Contatto maschio (presa o spina) ............................................................................................. 03-03-03
Coppia coassiale collegata ai morsetti ...................................................................................... 03-01-12
Coppia coassiale schermata....................................................................................................... 03-01-13
Coppia coassiale, segno grafico generale................................................................................. 03-01-11
Derivazione ................................................................................................................................ 03-02-01
Derivazione che richiede un utensile speciale......................................................................... 03-02-17
Dispositivo di connessione........................................................................................................ 03-03-01
Dispositivo di connessione, connettore a presa e spina, maschio-femmina.......................... 03-03-21
Dispositivo di connessione, connettore a presa e spina, maschio-maschio (ponticello) ...... 03-03-20
Dispositivo di connessione, connettore a presa e spina, maschio-maschio con presa di derivazione ...................................................................................................................... 03-03-22
Dispositivo di connessione, connettore d’estremità a pressione............................................. 03-03-17
Dispositivo di connessione, presa (femmina) .......................................................................... 03-03-01
Dispositivo di connessione, presa (maschio) ........................................................................... 03-03-03
Dispositivo di connessione, presa e spina multipolari in rappresentazione unifilare ........... 03-03-08
Dispositivo di connessione, presa e spina, multipolari ........................................................... 03-03-07
Dispositivo di connessione, spina e presa ............................................................................... 03-03-05
Dispositivo di passaggio cavi .................................................................................................... 03-04-07
Dispositivo di passaggio di cavi................................................................................................ 03-04-07
Dispositivo di passaggio di cavi a tenuta di pressione............................................................ 03-04-07
Doppia connessione di conduttori............................................................................................ 03-02-06
Femmina di un connettore multicontatto ................................................................................. 03-03-01
Filo .............................................................................................................................................. 03-01-11
Gruppo di conduttori................................................................................................................. 03-01-01
Inversione di polarità................................................................................................................. 03-02-11
Jack ............................................................................................................................................. 03-03-14
Jack di interruzione o di separazione, tipo telefonico............................................................. 03-03-14
Linea ........................................................................................................................................... 03-01-01
Linea di propagazione ............................................................................................................... 03-01-01
Maschio di una parte di connettore multicontatto ................................................................... 03-03-03
Morsettiera .................................................................................................................................. 03-02-03
Morsetto...................................................................................................................................... 03-02-02
Parte di tenuta ............................................................................................................................ 03-04-07
Piastrina ...................................................................................................................................... 03-03-17
Piastrina di connessione ............................................................................................................ 03-03-17
Piastrina di connessione, aperta................................................................................................ 03-03-19
Piastrina di connessine, chiusa.................................................................................................. 03-03-17
Presa ........................................................................................................................................... 03-03-01
Presa del conduttore che non interrompe................................................................................ 03-02-16
Presa e spina .............................................................................................................................. 03-03-05
Presa e spina coassiali ............................................................................................................... 03-03-15
Presa e spina maschio-femmina................................................................................................ 03-03-21
Presa e spina maschio-maschio (ponticello) ............................................................................ 03-03-20
Presa e spina maschio-maschio con presa di derivazione ...................................................... 03-03-22
Presa e spina, multipolari .......................................................................................................... 03-03-07
Presa e spina, multipolari, rappresentazione unifilare............................................................. 03-03-08
Presa o spina (femmina) di un.................................................................................................. 03-03-01
Presa o spina (femmina), femmina di un connettore multicontatto ....................................... 03-03-01
Punto di connessione ................................................................................................................ 03-02-01
Punto neutro di un sistema polifase ......................................................................................... 03-02-13
![Page 23: CEI EN 60617-3 (1997) [CEI 3-15]](https://reader034.fdocuments.net/reader034/viewer/2022042423/55cf9c0e550346d033a86719/html5/thumbnails/23.jpg)
NORMA TECNICACEI EN 60617-3:1997-11
Pagina 17 di 18
Punto neutro, alternatore trifase................................................................................................ 03-02-14
Sbarre collettrici.......................................................................................................................... 03-01-08
Spina ........................................................................................................................................... 03-03-03
Spina e presa (jack) bipolare, tipo telefonico .......................................................................... 03-03-12
Spina e presa (jack) tripolare, tipo telefonico (jack con contatti di apertura)........................ 03-03-13
Spina o presa, maschio di una parte di connettore multicontatto .......................................... 03-03-03
Terminazione.............................................................................................................................. 03-04-01
Terminazione con tre cavi unipolari ......................................................................................... 03-04-02
Terminazione con un cavo tripolare......................................................................................... 03-04-01
Tipo telefonico di jack di interruzione o di separazione......................................................... 03-03-14
Tipo telefonico di spina e presa (jack) bipolare ...................................................................... 03-03-12
Tipo telefonico di spina e presa (jack) con contatti di apertura ............................................. 03-03-13
Trasposizione di conduttori ....................................................................................................... 03-02-11
Fine Documento
![Page 24: CEI EN 60617-3 (1997) [CEI 3-15]](https://reader034.fdocuments.net/reader034/viewer/2022042423/55cf9c0e550346d033a86719/html5/thumbnails/24.jpg)
NORMA TECNICACEI EN 60617-3:1997-11Totale Pagine 24
La presente Norma è stata compilata dal Comitato Elettrotecnico Italiano e beneficia del riconoscimento di cui alla legge 1º Marzo 1968, n. 186.
Editore CEI, Comitato Elettrotecnico Italiano, Milano - Stampa in proprioAutorizzazione del Tribunale di Milano N. 4093 del 24 luglio 1956
Responsabile: Ing. E. Camagni
Sede del Punto di Vendita e di Consultazione 20126 Milano - Viale Monza, 261tel. 02/25773.1 • fax 02/25773.222 • E-MAIL [email protected]
Lire 74.000
3 – Documentazione e segni grafici
CEI 3 Schemi dei circuiti elettrici degli impianti di segnalamento fer-roviario
CEI 3-5 Segni grafici per trazione elettrica ferroviaria, tranviaria e filov-iaria
CEI 3-7 Segni grafici per i piani schematici di posa dei cavi per tele-comunicazione, segnalamento e sicurezza e per distribuzionedi energia elettrica negli impianti ferrotranviari
CEI 3-8 Sigle e segni grafici per i piani schematici degli impianti di seg-nalamento ferroviario
CEI 3-14 Segni grafici per schemi Parte 2°: Elementi dei segni grafici, segni grafici distintivi esegni di uso generale
CEI 3-15 Segni grafici per schemi Parte 3°: Conduttori e dispositivi di connessione
CEI EN 60617-4 (CEI 3-16) Segni grafici per schemi Parte 4: Componenti passivi
CEI EN 60617-5 (CEI 3-17) Segni grafici per schemi Parte 5: Semiconduttori e tubi elettronici
CEI 3-18 Segni grafici per schemi Parte 6°: Produzione, trasformazione e conversione dell’ener-gia elettrica
CEI 3-19 Segni grafici per schemi Parte 7°: Apparecchiature e dispositivi di comando e protezi-one
CEI 3-20 Segni grafici per schemi Parte 8°: Strumenti di misura, lampade e dispositivi di seg-nalazione
CEI EN 60617-9 (CEI 3-21) Segni grafici per schemi Parte 9: Telecomunicazioni: Apparati di commutazione e per-iferiche
CEI 3-22 Segni grafici per schemi Parte 10°: Telecomunicazioni - Trasmissione
CEI 3-23 Segni grafici per schemi Parte 11°: Schemi e piani d’installazione architettonici e to-pografici
CEI EN 60617-13 (CEI 3-24) Segni grafici per schemi Parte 13: Elementi analogici
CEI 3-25 Segni grafici per schemi Parte 1°: Generalità
CEI 3-26 Segni grafici per schemi Parte 12°: Elementi logici binari
CEI 3-27 Segni grafici da utilizzare sulle apparecchiature - Indice, som-mario e compilazione dei singoli fogli
CEI 3-28 Principi generali per l’elaborazione di segni grafici da utilizzaresulle apparecchiature
CEI 3-30 Segni grafici per impianti termoelettrici e nucleotermoelettrici
CEI 3-31 Segni grafici per impianti idroelettrici
CEI 3-34 Codice di identificazione dei materiali da utilizzare nella tecno-logia elettrica
CEI 3-35 Preparazione dei diagrammi funzionali per sistemi di comandoe controllo
CEI EN 61082-1 (CEI 3-36) Preparazione di documenti utilizzati in elettrotecnica.Parte 1: Prescrizioni generali
CEI EN 61175 (CEI 3-37) Designazione di segnali e connessioni
CEI EN 61082-2 (CEI 3-38) Preparazione di documenti utilizzati in elettrotecnica Parte 2: Schemi orientati alla funzione
CEI EN 61082-3 (CEI 3-39) Preparazione di documenti utilizzati in elettrotecnicaParte 3: Schemi, tabelle e liste delle connessioni
CEI EN 61360-1 (CEI 3-40) Tipi normalizzati di elementi di dati con schema di classificazi-one per componenti elettrici Parte 1: Definizioni - Principi e metodi
CEI EN 61286 (CEI 3-41) Tecnica dell’informazione Insieme di caratteri grafici codificatida usare nella preparazione di documenti utilizzati nell’elettro-tecnica e per lo scambio di informazioni
CEI EN 61082-4 (CEI 3-42) Preparazione di documenti utilizzati in elettrotecnicaParte 4: Documenti di disposizione e di installazione
CEI EN 61346-1 (CEI 3-43) Sistemi industriali, installazioni e apparecchi e prodotti indus-triali Principi di strutturazione e designazioni di riferimentoParte 1: Regole di base