CE INNOVATIONS LTD - Product Categoryceinnov.com/images/download/LM79Report IR-P4... ·...

22
NVLAP LAB CODE 201011-0 Report No.: GZE151208-A-PL Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0 Report Format Number STD/QR4909-A/2 AddressStandard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com 1 / 22 LM-79-08 Test Report For CE INNOVATIONS LTD (Brand Name: IRICO) 911 Denison St Markham, ON L3R 3K4 Canada 2x2 Luminaires for Ambient Lighting of Interior Commercial Spaces Model name(s): IR-P4-40W2B24400LM AC100-382V (3500K) IR-P4-40W2B24400LM AC100-382V (4000K) IR-P4-40W2B24400LM AC100-382V (4500K) IR-P4-40W2B24400LM AC100-382V (5000K) Remark: This is a multiple listed report; the Project Number of the original report is GZE151208-A Representative (Tested) Model: IR-P4-40W2B24400LM AC100-382V (3500K) IR-P4-40W2B24400LM AC100-382V (4000K) IR-P4-40W2B24400LM AC100-382V (5000K) Model Difference: All construction and rating are the same, except CCT Test & Report By: Review By: Johnson Sun Engineer: Johnson Sun Manager: Tommy Liang Date: Dec.08,2015 Note: This report does not imply product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.

Transcript of CE INNOVATIONS LTD - Product Categoryceinnov.com/images/download/LM79Report IR-P4... ·...

Page 1: CE INNOVATIONS LTD - Product Categoryceinnov.com/images/download/LM79Report IR-P4... · Chromaticity (u’, v’) u'=0.2369 v'=0.5112 R7 81 R15 76 Duv -0.0006 R8 60 -- -- Goniophotometer

NVLAP LAB CODE 201011-0

Report No.: GZE151208-A-PL

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

1 / 22

LM-79-08 Test Report

For

CE INNOVATIONS LTD

(Brand Name: IRICO)

911 Denison St Markham, ON L3R 3K4

Canada

2x2 Luminaires for Ambient Lighting of Interior

Commercial Spaces

Model name(s): IR-P4-40W2B24400LM AC100-382V (3500K)

IR-P4-40W2B24400LM AC100-382V (4000K)

IR-P4-40W2B24400LM AC100-382V (4500K)

IR-P4-40W2B24400LM AC100-382V (5000K)

Remark: This is a multiple listed report; the Project Number of the original report is

GZE151208-A

Representative (Tested) Model: IR-P4-40W2B24400LM AC100-382V (3500K)

IR-P4-40W2B24400LM AC100-382V (4000K)

IR-P4-40W2B24400LM AC100-382V (5000K)

Model Difference: All construction and rating are the same, except CCT

Test & Report By: Review By:

Johnson Sun

Engineer: Johnson Sun Manager: Tommy Liang

Date: Dec.08,2015

Note: This report does not imply product certification, approval, or endorsement by NVLAP, NIST, or

any agency of the Federal Government.

Page 2: CE INNOVATIONS LTD - Product Categoryceinnov.com/images/download/LM79Report IR-P4... · Chromaticity (u’, v’) u'=0.2369 v'=0.5112 R7 81 R15 76 Duv -0.0006 R8 60 -- -- Goniophotometer

NVLAP LAB CODE 201011-0

Report No.: GZE151208-A-PL

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

2 / 22

U.S. Department of Energy

Lighting FactsTM

Uniform LM-79 Reporting Template

Laboratory Information:

Name of Test Laboratory Standard-Tech Co. Ltd

Date of Test Report Dec.08, 2015

Test Report No. GZE151208-A-PL

Laboratory Contact Name Tommy Liang

Product Information:

Organization Name CE INNOVATIONS LTD

Brand Name IRICO

Model Number IR-P4-40W2B24400LM AC100-382V (3500K)

SKU (if available) N/A

Type of Luminaire

(for integral lamps, list base type and lamp type)

2x2 Luminaires for Ambient Lighting of Interior

Commercial Spaces

Luminaire Aperture (for downlights) -- in.

Luminaire Length -- mm

Luminaires Width -- mm

Number of Units (modular products) N/A

Electrical Measurements:

Integrating Sphere

Output

Goniophotometer

Output

Input Wattage -- 38.15 W

Input Current -- 0.3224 A

Input Voltage (ac) -- 120.0 V

Power Factor -- 0.9862

Off-State Power -- 0 W

Photometric Characteristics

Total Initial Lumen Output -- 4254.0 lm

Initial Lumen Efficacy -- 111.51 lm/w

Correlated color temperature / CCT 3464 -- K

Color rendering index / CRI 83.4 --

R9 Value 10 --

Duv -0.0006 --

Luminous Intensity Distribution

Center beam candlepower (if applicable)

-----

1482 cd

Beam angle (if applicable) 112.6 °

Zonal lumens in the 0°-60° zone 78.7 %

Zonal lumens in the 60°-90° zone 21.2 %

Zonal lumens in the 90°-120° zone 0 %

Zonal lumens in the 120°-180° zone 0 %

Page 3: CE INNOVATIONS LTD - Product Categoryceinnov.com/images/download/LM79Report IR-P4... · Chromaticity (u’, v’) u'=0.2369 v'=0.5112 R7 81 R15 76 Duv -0.0006 R8 60 -- -- Goniophotometer

NVLAP LAB CODE 201011-0

Report No.: GZE151208-A-PL

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

3 / 22

U.S. Department of Energy

Lighting FactsTM

Uniform LM-79 Reporting Template

Laboratory Information:

Name of Test Laboratory Standard-Tech Co. Ltd

Date of Test Report Dec.08, 2015

Test Report No. GZE151208-A-PL

Laboratory Contact Name Tommy Liang

Product Information:

Organization Name CE INNOVATIONS LTD

Brand Name IRICO

Model Number IR-P4-40W2B24400LM AC100-382V (4000K)

SKU (if available) N/A

Type of Luminaire

(for integral lamps, list base type and lamp type)

2x2 Luminaires for Ambient Lighting of Interior

Commercial Spaces

Luminaire Aperture (for downlights) -- in.

Luminaire Length -- mm

Luminaires Width -- mm

Number of Units (modular products) N/A

Electrical Measurements:

Integrating Sphere

Output

Goniophotometer

Output

Input Wattage 38.02 -- W

Input Current 0.3215 -- A

Input Voltage (ac) 120.0 -- V

Power Factor 0.9856 --

Off-State Power 0 -- W

Photometric Characteristics

Total Initial Lumen Output 4325 -- lm

Initial Lumen Efficacy 113.76 -- lm/w

Correlated color temperature / CCT 4028 -- K

Color rendering index / CRI 83.3 --

R9 Value 9 --

Duv 0.0039 --

Luminous Intensity Distribution

Center beam candlepower (if applicable)

----- -----

cd

Beam angle (if applicable) °

Zonal lumens in the 0°-60° zone %

Zonal lumens in the 60°-90° zone %

Zonal lumens in the 90°-120° zone %

Zonal lumens in the 120°-180° zone %

Page 4: CE INNOVATIONS LTD - Product Categoryceinnov.com/images/download/LM79Report IR-P4... · Chromaticity (u’, v’) u'=0.2369 v'=0.5112 R7 81 R15 76 Duv -0.0006 R8 60 -- -- Goniophotometer

NVLAP LAB CODE 201011-0

Report No.: GZE151208-A-PL

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

4 / 22

U.S. Department of Energy

Lighting FactsTM

Uniform LM-79 Reporting Template

Laboratory Information:

Name of Test Laboratory Standard-Tech Co. Ltd

Date of Test Report Dec.08, 2015

Test Report No. GZE151208-A-PL

Laboratory Contact Name Tommy Liang

Product Information:

Organization Name CE INNOVATIONS LTD

Brand Name IRICO

Model Number IR-P4-40W2B24400LM AC100-382V (5000K)

SKU (if available) N/A

Type of Luminaire

(for integral lamps, list base type and lamp type)

2x2 Luminaires for Ambient Lighting of Interior

Commercial Spaces

Luminaire Aperture (for downlights) -- in.

Luminaire Length -- mm

Luminaires Width -- mm

Number of Units (modular products) N/A

Electrical Measurements:

Integrating Sphere

Output

Goniophotometer

Output

Input Wattage 37.95 -- W

Input Current 0.3214 -- A

Input Voltage (ac) 120.0 -- V

Power Factor 0.9841 --

Off-State Power 0 -- W

Photometric Characteristics

Total Initial Lumen Output 4392 -- lm

Initial Lumen Efficacy 115.73 -- lm/w

Correlated color temperature / CCT 4938 -- K

Color rendering index / CRI 79.2 --

R9 Value 0 --

Duv 0.0050 --

Luminous Intensity Distribution

Center beam candlepower (if applicable)

----- -----

cd

Beam angle (if applicable) °

Zonal lumens in the 0°-60° zone %

Zonal lumens in the 60°-90° zone %

Zonal lumens in the 90°-120° zone %

Zonal lumens in the 120°-180° zone %

Page 5: CE INNOVATIONS LTD - Product Categoryceinnov.com/images/download/LM79Report IR-P4... · Chromaticity (u’, v’) u'=0.2369 v'=0.5112 R7 81 R15 76 Duv -0.0006 R8 60 -- -- Goniophotometer

NVLAP LAB CODE 201011-0

Report No.: GZE151208-A-PL

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

5 / 22

Test Specifications:

Date of Receipt : Dec.02, 2015

Date of Test : Dec.07, 2015

Test item : Total Luminous Flux, Luminous Distribution Intensity, Luminous

Efficacy, Correlated Color Temperature, Color Rendering Index,

Chromaticity Coordinate, Electrical parameters

Reference Standard IES LM-79-2008 Electrical and Photometric Measurements of Solid-State

Lighting Products

ANSI C78.377-2008 Specifications for the Chromaticity of Solid State

Lighting Products

CIE 13.3-1995 Method of Measuring and Specifying Colour Rendering

Properties of Light Sources

CIE 15-2004 Technical Report Colorimetry

IESNA LM-16-93 Practical Guide to Colorimetry of Light Source

IESNA TM-16-05 Technical Memorandum on Light Emitting Diode (LED)

Sources and Systems

Reference Work

Instruction

QD25

Test Methods

1. Photometric and Electrical measurements – Light Distribution Method:

Photometric parameters were measured using the goniophotometer and software. The ambient

temperature shall be maintained at 25° C ± 1° C, measured at a point not more than 1 m from the

sample and at the same height as the sample. The sample was operated at 120 Volts AC, 60Hz. It was

stabilized before measurement was made. Luminous flux, luminaire efficacy, zonal lumen were

calculated from the software taken at 1° vertical intervals and 22.5° horizontal intervals.

2. Photometric and Electrical Measurements – Integrating Sphere Method:

Photometric parameters were measured using an integrating sphere, a spectroradiometer and software.

The ambient temperature condition inside the sphere was maintained at 25º C ± 1º C. The sample

measurements were made using a spectroradiometer connected by a fiber optic cable and detector

through the detector port of the integrating sphere. The sample was operated at 120 Volts AC, 60Hz. It

was stabilized before measurement was made. Chromaticity coordinates, correlated color temperature

and color rendering index were calculated from the spectral radiant flux measurements taken at least 5

nm intervals over the range of 380 to 780 nm.

Page 6: CE INNOVATIONS LTD - Product Categoryceinnov.com/images/download/LM79Report IR-P4... · Chromaticity (u’, v’) u'=0.2369 v'=0.5112 R7 81 R15 76 Duv -0.0006 R8 60 -- -- Goniophotometer

NVLAP LAB CODE 201011-0

Report No.: GZE151208-A-PL

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

6 / 22

1. Product Information:

Brand Name IRICO

Model Number IR-P4-40W2B24400LM AC100-382V (3500K)

IR-P4-40W2B24400LM AC100-382V (4000K)

IR-P4-40W2B24400LM AC100-382V (4500K)

IR-P4-40W2B24400LM AC100-382V (5000K)

Luminaire Type 2x2 Luminaires for Ambient Lighting of Interior

Commercial Spaces

Rated Voltage / Frequency 100 ~ 382 Vac, 50/60 Hz

Nominal Power 40W

Rated Initial Lamp Lumen --

Declared CCT 3500K,4000K,4500K,5000K

LED Manufacturer EVERLIGHT ELECTRONICS CO., LTD

LED Model 67-21S Series

Sample Receipt Date Dec.02, 2015

Sample Number GZE151208-A1(3500K), A2(4000K)A3(5000K)

Photo

Page 7: CE INNOVATIONS LTD - Product Categoryceinnov.com/images/download/LM79Report IR-P4... · Chromaticity (u’, v’) u'=0.2369 v'=0.5112 R7 81 R15 76 Duv -0.0006 R8 60 -- -- Goniophotometer

NVLAP LAB CODE 201011-0

Report No.: GZE151208-A-PL

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

7 / 22

Test date 2015-12-07 Test Ambient: 25.2 º C

Test Orientation Horizontal Stabilization Time (min) 90

Model Number IR-P4-40W2B24400LM AC100-382V (3500K)

Electrical Measurement:

Sample No. Voltage (Vac) Frequency (Hz ) Current (A) Power (W) Power Factor THD %

GZE151208

-A1

120.0 60 0.3224 38.15 0.9862 7.59

382.0 60 0.1094 37.83 0.9049 12.35

Color Data:

Parameter Result Special Color Rendering Indices

Test Voltage (V) 120.0 R1 84 R9 10

Frequency (Hz) 60 R2 95 R10 89

Color Rendering Index (CRI) 83.4 R3 92 R11 79

R9 10 R4 79 R12 69

CCT (K) 3461 R5 84 R13 87

Chromaticity (x, y) x=0.4067 y=0.3900 R6 93 R14 96

Chromaticity (u’, v’) u'=0.2369 v'=0.5112 R7 81 R15 76

Duv -0.0006 R8 60 -- --

Goniophotometer Method:

Parameter Result

Test Voltage (V) 120.0

Frequency (Hz) 60

Total Luminous (lm) 4254.0

Luminous Efficacy (lm/W) 111.51

Beam Angle° 112.6

Center Beam Candle Power (cd) 1482

S/MH(C0/180) 1.23

S/MH(C90/270) 1.29

Goniophotometer Method:

Parameter Result

Test Voltage (V) 382.0

Frequency (Hz) 60

Total Luminous (lm) 4199.9

Luminous Efficacy (lm/W) 110.02

2. Electrical, Photometric and Chromaticity Measurements

(Refer to Work Instruction QD25)

IES LM-79 2008

Page 8: CE INNOVATIONS LTD - Product Categoryceinnov.com/images/download/LM79Report IR-P4... · Chromaticity (u’, v’) u'=0.2369 v'=0.5112 R7 81 R15 76 Duv -0.0006 R8 60 -- -- Goniophotometer

NVLAP LAB CODE 201011-0

Report No.: GZE151208-A-PL

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

8 / 22

Spectral Power Distribution AND Chromaticity Diagram

Spectral Power Distribution:

Page 9: CE INNOVATIONS LTD - Product Categoryceinnov.com/images/download/LM79Report IR-P4... · Chromaticity (u’, v’) u'=0.2369 v'=0.5112 R7 81 R15 76 Duv -0.0006 R8 60 -- -- Goniophotometer

NVLAP LAB CODE 201011-0

Report No.: GZE151208-A-PL

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

9 / 22

Zonal Lumen Tabulation

Zonal Lumen Summary

Zone Lumens % Luminaire

0-30 1,154.5 27.1%

0-40 1,893.4 44.5%

0-60 3,349.2 78.7%

60-90 903.0 21.2%

70-100 379.3 8.9%

90-120 0.1 0%

0-90 4,252.1 100%

90-180 1.5 0%

0-180 4,253.6 100%

Lumens Per Zone

Zone Lumens % Total Zone Lumens % Total

0-10 140.2 3.3% 90-100 0.0 0%

10-20 402.4 9.5% 100-110 0.0 0%

20-30 611.8 14.4% 110-120 0.1 0%

30-40 738.9 17.4% 120-130 0.1 0%

40-50 765.7 18.0% 130-140 0.2 0%

50-60 690.0 16.2% 140-150 0.3 0%

60-70 523.7 12.3% 150-160 0.4 0%

70-80 300.8 7.1% 160-170 0.3 0%

80-90 78.5 1.8% 170-180 0.1 0%

Page 10: CE INNOVATIONS LTD - Product Categoryceinnov.com/images/download/LM79Report IR-P4... · Chromaticity (u’, v’) u'=0.2369 v'=0.5112 R7 81 R15 76 Duv -0.0006 R8 60 -- -- Goniophotometer

NVLAP LAB CODE 201011-0

Report No.: GZE151208-A-PL

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

10 / 22

Photometric Data

Illuminance Plots

Page 11: CE INNOVATIONS LTD - Product Categoryceinnov.com/images/download/LM79Report IR-P4... · Chromaticity (u’, v’) u'=0.2369 v'=0.5112 R7 81 R15 76 Duv -0.0006 R8 60 -- -- Goniophotometer

NVLAP LAB CODE 201011-0

Report No.: GZE151208-A-PL

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

11 / 22

ISOCANDELA DIAGRAM

ISOLUX DIAGRAM

Page 12: CE INNOVATIONS LTD - Product Categoryceinnov.com/images/download/LM79Report IR-P4... · Chromaticity (u’, v’) u'=0.2369 v'=0.5112 R7 81 R15 76 Duv -0.0006 R8 60 -- -- Goniophotometer

NVLAP LAB CODE 201011-0

Report No.: GZE151208-A-PL

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

12 / 22

Candela Table - Type C

0 22.5 45 67.5 90 112.5 135 157.5 180 202.5 225 247.5 270 292.5 315 337.5 360

0 1482 1482 1482 1482 1482 1482 1482 1482 1482 1482 1482 1482 1482 1482 1482 1482 1482

1 1482 1482 1482 1482 1482 1481 1481 1481 1481 1481 1481 1481 1481 1482 1482 1482 1482

2 1482 1482 1482 1482 1481 1481 1480 1481 1480 1480 1479 1479 1481 1481 1482 1482 1482

3 1481 1481 1481 1481 1479 1479 1479 1479 1479 1479 1478 1478 1479 1480 1480 1481 1481

4 1480 1480 1479 1479 1476 1477 1477 1477 1477 1477 1475 1475 1478 1478 1479 1480 1480

5 1479 1479 1477 1477 1474 1474 1474 1475 1475 1474 1472 1472 1475 1476 1477 1478 1479

6 1477 1477 1475 1474 1470 1470 1471 1473 1472 1471 1470 1468 1471 1472 1475 1476 1477

7 1475 1474 1472 1470 1466 1466 1468 1470 1469 1468 1466 1464 1467 1469 1471 1473 1475

8 1472 1472 1469 1466 1462 1461 1464 1466 1466 1465 1461 1459 1463 1464 1468 1471 1472

9 1469 1469 1465 1461 1456 1456 1460 1462 1462 1460 1456 1453 1458 1460 1464 1467 1469

10 1466 1466 1461 1456 1450 1451 1454 1458 1458 1456 1451 1447 1452 1454 1459 1464 1466

11 1463 1462 1457 1450 1443 1444 1449 1453 1454 1451 1446 1440 1446 1449 1454 1460 1463

12 1459 1458 1452 1444 1436 1437 1443 1448 1450 1446 1440 1433 1439 1442 1449 1455 1459

13 1454 1452 1447 1437 1429 1430 1436 1442 1444 1441 1433 1426 1431 1435 1443 1450 1454

14 1450 1448 1440 1430 1420 1422 1429 1436 1439 1435 1426 1418 1423 1428 1436 1445 1450

15 1444 1442 1434 1422 1412 1414 1422 1429 1433 1428 1418 1409 1415 1420 1430 1439 1444

16 1439 1436 1426 1414 1403 1406 1414 1423 1427 1421 1410 1400 1406 1412 1423 1433 1439

17 1433 1430 1419 1405 1393 1396 1406 1415 1420 1414 1401 1389 1396 1403 1415 1426 1433

18 1426 1423 1410 1396 1383 1386 1397 1408 1412 1406 1392 1379 1386 1393 1407 1419 1426

19 1420 1416 1402 1386 1372 1376 1387 1400 1404 1398 1383 1368 1375 1384 1398 1411 1420

20 1412 1408 1392 1375 1360 1365 1377 1391 1396 1389 1372 1357 1364 1373 1389 1404 1412

21 1405 1400 1383 1364 1348 1353 1367 1382 1388 1380 1361 1344 1352 1363 1379 1395 1405

22 1397 1391 1372 1353 1336 1341 1356 1372 1379 1370 1350 1332 1341 1351 1369 1387 1397

23 1388 1382 1361 1341 1323 1329 1345 1362 1369 1360 1338 1319 1328 1339 1358 1377 1388

24 1379 1372 1351 1328 1310 1316 1333 1351 1359 1349 1326 1306 1315 1326 1346 1367 1379

25 1370 1362 1339 1315 1296 1302 1320 1340 1348 1338 1314 1292 1301 1313 1334 1357 1370

26 1359 1351 1327 1302 1282 1288 1307 1328 1337 1326 1301 1279 1287 1300 1322 1346 1359

27 1349 1340 1314 1288 1267 1273 1294 1316 1325 1314 1287 1264 1272 1286 1310 1334 1349

28 1338 1328 1301 1274 1252 1259 1280 1303 1313 1301 1273 1249 1258 1271 1296 1323 1338

29 1326 1316 1287 1260 1236 1244 1266 1290 1300 1288 1259 1234 1243 1256 1283 1311 1326

Page 13: CE INNOVATIONS LTD - Product Categoryceinnov.com/images/download/LM79Report IR-P4... · Chromaticity (u’, v’) u'=0.2369 v'=0.5112 R7 81 R15 76 Duv -0.0006 R8 60 -- -- Goniophotometer

NVLAP LAB CODE 201011-0

Report No.: GZE151208-A-PL

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

13 / 22

30 1314 1304 1273 1245 1221 1228 1251 1276 1288 1274 1243 1218 1227 1241 1268 1298 1314

31 1301 1290 1258 1230 1204 1212 1236 1262 1274 1260 1229 1201 1210 1225 1254 1284 1301

32 1287 1276 1243 1213 1188 1196 1220 1247 1259 1245 1213 1184 1194 1209 1239 1270 1287

33 1273 1262 1228 1197 1171 1179 1204 1232 1244 1230 1196 1167 1177 1193 1223 1256 1273

34 1259 1247 1212 1180 1154 1162 1188 1216 1229 1214 1179 1150 1160 1176 1208 1241 1259

35 1244 1232 1196 1163 1136 1145 1171 1200 1213 1198 1162 1132 1142 1159 1192 1225 1244

36 1230 1216 1180 1145 1118 1127 1154 1183 1197 1181 1145 1114 1124 1141 1175 1209 1230

37 1213 1200 1163 1127 1099 1109 1136 1166 1180 1164 1127 1096 1106 1124 1157 1193 1213

38 1196 1183 1145 1108 1081 1089 1118 1149 1162 1146 1109 1077 1087 1105 1139 1176 1196

39 1178 1165 1126 1090 1062 1071 1099 1131 1144 1128 1090 1058 1067 1085 1120 1158 1178

40 1160 1147 1108 1070 1042 1051 1080 1112 1126 1109 1071 1039 1047 1065 1102 1140 1160

41 1142 1129 1089 1052 1022 1032 1060 1093 1107 1090 1051 1019 1028 1046 1083 1122 1142

42 1124 1110 1070 1031 1002 1012 1041 1074 1088 1071 1031 999 1008 1027 1063 1103 1124

43 1104 1092 1051 1013 982 991 1021 1054 1068 1051 1011 979 988 1007 1044 1084 1104

44 1086 1072 1031 992 962 971 1001 1034 1048 1031 991 958 967 987 1025 1065 1086

45 1066 1051 1011 973 941 950 980 1013 1027 1010 970 938 947 967 1005 1045 1066

46 1045 1032 991 951 921 929 959 992 1006 988 949 916 926 945 983 1024 1045

47 1025 1011 970 931 899 908 938 971 984 967 928 895 906 925 964 1005 1025

48 1005 990 950 910 878 887 916 950 963 945 906 873 884 904 942 984 1005

49 982 969 928 889 856 865 894 927 940 923 884 852 863 883 920 962 982

50 961 947 907 867 835 843 872 905 918 900 862 830 842 861 899 940 961

51 937 925 884 844 813 821 850 883 895 877 839 808 820 838 877 918 937

52 914 901 863 824 791 799 827 859 872 854 817 785 798 816 855 894 914

53 890 879 840 802 769 776 805 836 848 831 794 763 776 794 833 871 890

54 866 854 817 780 746 754 781 812 824 807 770 740 754 772 810 847 866

55 842 830 794 756 724 731 758 789 799 783 747 718 731 749 787 824 842

56 817 806 771 734 701 708 734 764 774 758 723 695 708 726 764 799 817

57 792 781 749 711 679 685 710 739 749 734 700 671 685 704 741 774 792

58 766 757 725 688 656 662 687 714 723 709 676 648 663 681 717 750 766

59 741 731 701 665 632 639 662 688 697 683 652 625 640 658 694 725 741

60 715 706 677 642 610 615 639 663 672 658 628 601 617 634 670 699 715

61 689 680 652 619 586 592 615 637 646 632 604 578 594 611 645 673 689

Page 14: CE INNOVATIONS LTD - Product Categoryceinnov.com/images/download/LM79Report IR-P4... · Chromaticity (u’, v’) u'=0.2369 v'=0.5112 R7 81 R15 76 Duv -0.0006 R8 60 -- -- Goniophotometer

NVLAP LAB CODE 201011-0

Report No.: GZE151208-A-PL

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

14 / 22

62 664 655 628 596 563 568 591 611 620 606 579 554 571 588 620 648 664

63 638 629 603 572 540 544 566 585 593 580 555 530 548 564 596 622 638

64 610 602 578 549 517 520 541 559 567 554 531 507 524 540 571 596 610

65 585 576 553 525 493 497 516 533 540 528 506 483 501 516 545 571 585

66 558 550 528 502 470 473 491 506 513 502 481 460 478 494 520 545 558

67 532 524 503 479 446 449 466 481 487 476 456 436 455 469 494 518 532

68 505 497 477 455 423 426 441 455 460 450 431 413 432 446 470 492 505

69 478 472 453 433 400 403 416 429 434 424 406 390 408 423 445 467 478

70 452 446 428 408 377 379 392 403 408 398 382 367 386 399 420 440 452

71 426 419 403 386 354 356 367 377 381 372 357 344 362 376 395 414 426

72 399 393 378 362 331 333 343 352 356 347 333 321 339 352 370 389 399

73 373 368 354 339 308 311 319 327 329 321 309 298 317 330 346 364 373

74 348 343 330 316 286 288 295 302 304 297 285 276 295 307 322 338 348

75 321 317 305 293 263 266 271 277 279 272 262 254 272 283 298 312 321

76 296 293 282 271 241 243 248 253 255 248 239 231 249 261 274 288 296

77 271 268 258 247 218 220 225 229 230 225 216 209 227 238 250 264 271

78 246 244 235 224 196 197 203 206 207 202 194 186 205 215 228 239 246

79 222 220 212 202 175 175 181 184 184 180 172 165 183 192 205 215 222

80 198 196 190 179 154 154 159 162 161 158 150 144 163 170 183 192 198

81 175 174 168 157 133 133 137 140 139 136 129 124 142 149 160 169 175

82 152 151 145 137 114 112 115 119 118 115 108 104 122 128 138 147 152

83 130 130 124 116 95 93 95 99 98 95 88 85 103 108 117 126 130

84 109 109 103 96 76 74 75 78 78 75 69 67 84 88 96 105 109

85 89 89 82 77 58 56 56 59 59 55 51 49 66 70 76 85 89

86 69 69 63 59 41 39 39 40 41 37 33 32 49 52 57 65 69

87 51 50 45 41 25 22 22 23 23 20 17 17 32 35 39 46 51

88 33 32 28 25 10 8 8 7 8 6 4 4 17 19 23 29 33

89 17 16 13 10 0 0 0 0 0 0 0 0 3 5 9 13 17

90 1 2 1 0 0 0 0 0 0 0 0 0 0 0 0 0 1

91 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

92 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

93 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

Page 15: CE INNOVATIONS LTD - Product Categoryceinnov.com/images/download/LM79Report IR-P4... · Chromaticity (u’, v’) u'=0.2369 v'=0.5112 R7 81 R15 76 Duv -0.0006 R8 60 -- -- Goniophotometer

NVLAP LAB CODE 201011-0

Report No.: GZE151208-A-PL

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

15 / 22

94 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

95 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

96 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

97 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

98 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

100 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

101 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

102 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

103 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

104 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

105 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

106 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

107 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

108 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

109 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

110 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

111 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

112 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

113 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

114 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

115 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

116 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

117 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

118 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

119 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

120 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

121 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

122 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

123 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

124 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

125 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

Page 16: CE INNOVATIONS LTD - Product Categoryceinnov.com/images/download/LM79Report IR-P4... · Chromaticity (u’, v’) u'=0.2369 v'=0.5112 R7 81 R15 76 Duv -0.0006 R8 60 -- -- Goniophotometer

NVLAP LAB CODE 201011-0

Report No.: GZE151208-A-PL

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

16 / 22

126 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

127 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0

128 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0

129 0 0 0 0 0 0 0 1 1 1 0 0 0 0 0 0 0

130 0 0 0 0 1 0 0 1 1 1 0 0 0 0 0 0 0

131 0 0 0 0 1 0 0 1 1 1 0 0 0 0 0 0 0

132 0 0 0 0 1 0 0 1 1 1 0 0 0 0 0 0 0

133 0 0 0 0 1 0 0 1 1 1 0 0 0 0 0 0 0

134 0 0 0 0 1 1 0 1 1 1 1 1 0 0 0 0 0

135 0 0 0 0 1 1 0 1 1 1 0 1 0 0 0 0 0

136 0 0 0 0 1 1 0 1 1 1 1 1 0 0 0 0 0

137 0 0 0 0 1 1 0 1 1 1 1 1 0 0 0 0 0

138 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0

139 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0

140 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0

141 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0

142 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0

143 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0

144 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0

145 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0

146 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0

147 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0

148 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0

149 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0

150 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0

151 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0

152 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0

153 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0

154 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0

155 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0

156 0 1 1 0 1 1 1 1 1 1 1 1 0 0 0 0 0

157 0 1 1 0 1 1 1 1 1 1 1 1 0 0 0 0 0

Page 17: CE INNOVATIONS LTD - Product Categoryceinnov.com/images/download/LM79Report IR-P4... · Chromaticity (u’, v’) u'=0.2369 v'=0.5112 R7 81 R15 76 Duv -0.0006 R8 60 -- -- Goniophotometer

NVLAP LAB CODE 201011-0

Report No.: GZE151208-A-PL

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

17 / 22

158 0 1 1 0 1 1 1 1 1 1 1 1 0 0 0 1 0

159 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 1

160 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 1 1

161 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 1 1

162 1 1 1 1 2 1 1 1 1 1 1 1 0 0 0 1 1

163 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 1 1

164 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 1 1

165 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

166 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

167 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

168 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

169 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

170 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

171 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

172 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

173 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

174 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

175 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

176 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

177 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

178 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

179 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

180 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

Page 18: CE INNOVATIONS LTD - Product Categoryceinnov.com/images/download/LM79Report IR-P4... · Chromaticity (u’, v’) u'=0.2369 v'=0.5112 R7 81 R15 76 Duv -0.0006 R8 60 -- -- Goniophotometer

NVLAP LAB CODE 201011-0

Report No.: GZE151208-A-PL

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

18 / 22

2.2 Electrical, Photometric and Chromaticity Measurements

(Refer to Work Instruction QD25)

IES LM-79 2008

Test date 2015-12-07 Test Ambient: 25.1 º C

Test Orientation Horizontal Stabilization Time (min) 90

Model Number IR-P4-40W2B24400LM AC100-382V

(4000K)

Electrical Measurement for Bare Lamp:

Sample No. Voltage (Vac) Frequency (Hz ) Current (A) Power (W) Power Factor THD %

GZE151208

-A2

120.0 60 0.3215 38.02 0.9856 7.96

382.0 60 0.1088 37.71 0.9074 12.73

Sphere-Spectroradiometer Method:

Parameter Result Special Color Rendering Indices

Test Voltage (V) 120.0 R1 81 R9 9

Frequency (Hz) 60 R2 90 R10 76

Color Rendering Index (CRI) 83.3 R3 96 R11 80

R9 9 R4 81 R12 60

CCT (K) 4028 R5 81 R13 84

Chromaticity (x, y) x=0.3819 y=0.3861 R6 86 R14 98

Chromaticity (u’, v’) u'=0.2224 v'=0.5059 R7 87 R15 75

Duv 0.0039 R8 65 -- --

Total Initial Lumen Output(lm) 4325

Initial Lumen Efficacy(lm/w) 113.76

Sphere-Spectroradiometer Method:

Parameter Result

Test Voltage (V) 382.0

Frequency (Hz) 60

Total Initial Lumen Output(lm) 4273

Initial Lumen Efficacy(lm/w) 113.31

Page 19: CE INNOVATIONS LTD - Product Categoryceinnov.com/images/download/LM79Report IR-P4... · Chromaticity (u’, v’) u'=0.2369 v'=0.5112 R7 81 R15 76 Duv -0.0006 R8 60 -- -- Goniophotometer

NVLAP LAB CODE 201011-0

Report No.: GZE151208-A-PL

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

19 / 22

Spectral Power Distribution AND Chromaticity Diagram

Spectral Power Distribution:

Page 20: CE INNOVATIONS LTD - Product Categoryceinnov.com/images/download/LM79Report IR-P4... · Chromaticity (u’, v’) u'=0.2369 v'=0.5112 R7 81 R15 76 Duv -0.0006 R8 60 -- -- Goniophotometer

NVLAP LAB CODE 201011-0

Report No.: GZE151208-A-PL

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

20 / 22

2.3 Electrical, Photometric and Chromaticity Measurements

(Refer to Work Instruction QD25)

IES LM-79 2008

Test date 2015-12-07 Test Ambient: 25.1 º C

Test Orientation Horizontal Stabilization Time (min) 90

Model Number IR-P4-40W2B24400LM AC100-382V

(5000K)

Electrical Measurement for Bare Lamp:

Sample No. Voltage (Vac) Frequency (Hz ) Current (A) Power (W) Power Factor THD %

GZE151208

-A3

120.0 60 0.3214 37.95 0.9841 8.03

382.0 60 0.1092 37.64 0.9026 12.73

Sphere-Spectroradiometer Method:

Parameter Result Special Color Rendering Indices

Test Voltage (V) 120.0 R1 77 R9 0

Frequency (Hz) 60 R2 86 R10 65

Color Rendering Index (CRI) 79.2 R3 92 R11 72

R9 0 R4 75 R12 45

CCT (K) 4938 R5 75 R13 79

Chromaticity (x, y) x=0.3480 y=0.3640 R6 79 R14 95

Chromaticity (u’, v’) u'=0.2086 v'=0.4910 R7 86 R15 71

Duv 0.0050 R8 62 -- --

Total Initial Lumen Output(lm) 4392

Initial Lumen Efficacy(lm/w) 115.73

Sphere-Spectroradiometer Method:

Parameter Result

Test Voltage (V) 382.0

Frequency (Hz) 60

Total Initial Lumen Output(lm) 4351

Initial Lumen Efficacy(lm/w) 115.60

Page 21: CE INNOVATIONS LTD - Product Categoryceinnov.com/images/download/LM79Report IR-P4... · Chromaticity (u’, v’) u'=0.2369 v'=0.5112 R7 81 R15 76 Duv -0.0006 R8 60 -- -- Goniophotometer

NVLAP LAB CODE 201011-0

Report No.: GZE151208-A-PL

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

21 / 22

Spectral Power Distribution AND Chromaticity Diagram

Spectral Power Distribution:

Page 22: CE INNOVATIONS LTD - Product Categoryceinnov.com/images/download/LM79Report IR-P4... · Chromaticity (u’, v’) u'=0.2369 v'=0.5112 R7 81 R15 76 Duv -0.0006 R8 60 -- -- Goniophotometer

NVLAP LAB CODE 201011-0

Report No.: GZE151208-A-PL

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

22 / 22

3. Test Equipment

Equipment ID Equipment Name Last Calibration Date Next Calibration Date

ST-R-336 2 meter Integrating Sphere 2015-06-30 2016-06-30

ST-R-331 Spectral analysis system HAAS-2000 2015-06-30 2016-06-30

D204 Standard Lamp 2015-06-30 2016-06-30

PF2010 Power Meter for Integrating Sphere 2015-06-30 2016-06-30

EE-09 Goniophotometer system 2015-06-30 2016-06-30

D908S Standard Lamp 2015-06-30 2016-06-30

PF210 Power Meter for Goniophotometer 2015-06-30 2016-06-30

ST-R-181A Temperature Tester 2015-06-30 2016-06-30

Uncertainty

Photometric Measurement (Sphere):1.74%

Chromaticity Measurement(Sphere):14.3K

Photometric Measurement(Goniophotometer):1.62%

****** END OF DATASHEET PACKAGE ******