C:Documents and Settings품질file2.dzsc.com/product/18/07/24/91403_165247640.pdf · 2018. 7....
Transcript of C:Documents and Settings품질file2.dzsc.com/product/18/07/24/91403_165247640.pdf · 2018. 7....
Item And Code No.
I T E M C O N N E C T O R
S P E C 7.92 Pitch Wire to Board DIP Type
M A K E R
S P E C
Y H 3 9 6 - 0 3 B R ( R E )
Y H 3 9 6 - 0 3 V R T ( R E )
Code No.
REMARK
The Best Partner for Electronic Circuits Connections www.yeonho.com
Specification Approval Sheet
Y H
H e a d O f f i c e& L a b o r a t o r y
K o r e a F a c t o r y
C h i n a F a c t o r y
Indonesia Factory
Philippines Factory
: 14F, 234, Teheranro, Gangnam-gu, Seoul, KoreaTEL: 02)3453-0871 FAX: 02)3453-1468
: 5 0 6 - 2 , H a n a m - d o n g , G w a n g s a n - g u , G w a n g j u , K o r e aTEL: 062)952-0772 FAX: 062)952-0782
: Yongsheng Industrial Area, Shebei, Huangjiang, Dongguan City, Guangdong Province, ChinaTEL: 86-769)8363-2525, 8525 FAX: 86-769)8363-5530
W u x i a I n d u s t r i a l A r e a A 1 0 , D o n g l i d i s t r i c t , T i a n j i n , C h i n aTEL: 86-22)2435-4110, 1737 FAX: 86-22)8436-7016
: JL.Industri Selatan 3A SFB blok GG3-C.D.E Jababeka Ⅱ Cikarang, Bekasi 17550, IndonesiaTEL: 62-21)898-33225 FAX: 62-21)898-33228
: Blk4, Lot6~9. Phase1, FCIE, Brgy. Langkaan, Dasmarinas, Cavite 4114, PhilippinesTEL: 63-46)402-1921, 1924 FAX: 63-46)402-1928
PRODUCT SPECIFICATION
Yeon Ho Electronics CO.,LTD
Y396 Series
P i t c h 7.92mm
Special Wire to Board
T y p e D I P
Y396 Series
Connector 제품규격Product Specification
제,개정 이력『History Revision』
Indemnification
Yeonho will indemnify, hold harmless, and at buyer's request, defend buyer and buyer's directors, officers,
employees, agents and independent contractors from and against any loss, cost, liability or expense
(including court costs and reasonable fees of attorneys and other professionals) arising out of or
resulting from any third party claim that any products and/or components provided by yeonho infringes
patent, copyright, trade secret right or other intellectual property right.
if yeonho receives notice of an alleged patent, copyright, trade secret or other intellectual property right
infringement or if buyer's use of the products and/or the components provided by yeonho shall be prevented
by permanent injunction for reasons of patent, copyright or trade secret infringement, yeonho may, at
its sole option and expense, procure for buyer the right to continued use of the products and/or the
components as provided hereunder, or modify the allegedly infringing item such that it is no longer
infringing, or replace the allegedly infringing item.
1 / 7
NO DATE ISS. CHK. APP. S U M M A R Y
1 2008.05.09 L.K.O K.S.I S.J.H Presentation
2 2012.03.26 L.J.H K.S.I C.G.N 총합삽입력,발거력 SPEC 변경
PRODUCT SPECIFICATION
Yeon Ho Electronics CO.,LTD
Y396 Series
아래와 같이 사양 승인원을 제출합니다.
『Yeon Ho Electronics CO.,LTD. submits the approval certification of connector
specification.』
1. 업 체 명 : (주) 연 호 전 자
『Manufactured by : Yeon Ho Electronics CO.,LTD.』
2. 기 안 부 서 : 품질관리실
『Written by : Quality Control Department』
♠♠♠ 목 차 『Contents』 ♠♠♠
1. 적용범위 『Scope』
2. 형명구성 『Numbering System of Products (Ordering Information of Products)』
3. 원 재 료 『Material Specifications』
4. 정 격 『Ratings』
5. 성 능 『Performance Characteristics』
6. 포장 및 식별표시 『Identification & Packing』
♠♠♠ 별 첨 『Attachment』 ♠♠♠
1. 검사성적서 『Inspection Data』
2. 사 양 도 『Drawings』
3. 재질증명서 『Material Certification』
4. 유해물질 분석 Data 『The Analysis Data of Toxic Substance』
5. 물질안전보건자료 『MSDS Data』
6. Q.C 공정도 『QC Process Chart』
2 / 7
PRODUCT SPECIFICATION
Yeon Ho Electronics CO.,LTD
Y396 Series
1. 적용 범위 『Scope』
본 사양서는 (주)연호전자 제품 Y396 series connector 한하여 적용한다.
『This specification covers the requirements for Y396 series connector』
2. 형명 구성『Numbering system of products(Ordering information of products)』
Y AW 396 - NN A B
Y H 396 - NN BR (RE)
YH396 - NN VRT(RE)
YT396B - RT
3. 원재료 『Material』
4. 정 격 『Ratings』
3 / 7
Parts : Wafer
Box Type
Number of CircuitsPin Missing
Series Name
Series Name
Number of CircuitsBox Type
Parts : Housing
Parts : Terminal
Parts : Retainer
항 목 (Item) 정 격 (Standard Data)
정격 전압 (Operating Voltage) AC/DC 250V
정격 전류 (Current Rating) AC/DC 7.5A
사용 온도 (Operating Temperature) - 25 ∼ + 85
적용 전선 (Applicable Wire) AWG #16 ∼ #20
적합 PCB (Applicable P.C.B) 1.2 ~ 1.6 mm
Item Material Maker Plated / Color
Wafer Material PA66 Rhodia Natural
Housing Material PA66 LG Chem Red
Retainer Material PA66 Rhodia Red
Pin MaterialBrassC2700
Poong San * Over plating : Sn(2-6)
Terminal MaterialPhosphor Bronze
C5210Poong San * Over plating : Pre-plated tin(1-2)
Color
PRODUCT SPECIFICATION
Yeon Ho Electronics CO.,LTD
Y396 Series
5. 성 능 『Performance Characteristics』
NO.시험항목
『Test Title』시 험 방 법 및 조 건
『Test Procedures/Methods Conditions』규 격
『Requirements』
1.외 관 치 수『Dimensions 』
첨부 제품도에 준한다.『Refer to drawings』
2. 전 기 적 성 능 『Electrical Characteristics』
2-1.절연저항
2-1.InsulationResistance
⊙ 인접 Terminal(Contact)간에 DC 500V ±5V 전압을1분±5초간 인가하였을 때 절연저항을 측정한다.(1회 측정에서 규격 치 미달인 경우 3시간 이내 재측정)
⊙ Measured between adjacent contacts⊙ Test voltage : DC 500V ±5V / 1 min ±5 sec(Based upon MIL-STD-202G Method 302 Condition B)
1000 이상
1000 MIN
2-2.내 전 압
2-2.DielectricWithstandingVoltage
⊙ 인접한 Terminal간에 AC 1500V 전압을 1분±5초간 인가한다.
⊙ Measured between adjacent contacts⊙ Test voltage : AC 1500V / 1 min ±5 sec(Based upon MIL-STD-202G Method 301)
절연파괴/섬락이 없고사용상 결함이 없을 것.
No flash over andno physical damageshall be observed
2-3.접촉저항
2-3.ContactResistance
⊙ Terminal과 Wafer Pin간의 접촉저항 측정 20mV. 10mA
⊙ Measured the resistance of mated connector, 20mV. 10mA
30mΩ 이하
30mΩ MAX
3. 물 리 적 성 질 『Physical characteristics』
3-1.납 땜 성
3-1.Solder Ability
⊙ FLUX (ROSIN 10%, METHANOL 90%)에 5∼10초 동안 담근 후SnAg(3.5)Cu(0.7)의 Pot 납땜조 온도 (240±5)에3초±0.5초 동안 침전시킨다.
⊙ Immersion in flux consisting of rosin 10% andmethanol 90% for a period of 5 to 10 seconds dipin molten solder consisting of SnAg(3.5)Cu(0.7) at240±5 degrees for 3±0.5 seconds.
침전 부위의 납땜이90% 이상일 것
More than 90% ofarea dipped in moltensolder should becoated by solder
3-2.납땜내열성
3-2.Solder HeatResistance
※ WAVE TYPE⊙ 온도 260±5 5±0.5초간 침적시킨다
※ WAVE TYPE⊙ solder consisting: 260±5 degrees for 5±0.5 seconds.
외관 변형등이 없을 것
Appearance : Good
3-3.Pin유지력
3-3.PinRetentionForce
⊙ 사출물(수지)이 PIN을 유지하고 있는 힘 측정* Pin을 25±3mm/min 속도로 뺄 때의 힘을 측정한다.
⊙ Measured withdrawal force that resin grips and supports Pin* Velocity of withdrawal : 25 ±3mm/min
1.0Kgf 이상
1.0Kgf MIN
4 / 7
PRODUCT SPECIFICATION
Yeon Ho Electronics CO.,LTD
Y396 Series
NO.시험항목
『Test Title』
시 험 방 법 및 조 건
『Test Procedures/Methods Conditions』
규 격
『Requirements』
3-4.총합삽입력
3-4.TotalInsertion Force
⊙ 회로수가 같은 Housing Ass`Y에 Wafer Ass`Y를삽입할 때의 힘 측정
⊙ Measured force to insert wafer assembly intothe housing assembly which has same circuits
3.50Kgf 이하
3.50Kgf MAX
3-5.총합발거력
3-5.TotalWithdrawal Force
⊙ 결합된 Housing Ass`Y로부터 Wafer Ass`Y를발거할 때의 힘 측정
⊙ Measured force to withdrawal wafer assembly fromthe housing assembly which has same circuits
0.15Kgf 이상
0.15Kgf MIN
3-6.내구성시험
3-6.Durabilityof ContactResistance
⊙ 결합된 제품 Housing Ass`Y과 Wafer Ass`Y의 삽입 및 분리동작을 10회/분 속도로 30회 행한 후 접촉저항 측정
⊙ Measured contact resistance after 30 cycles of totalinsertion and withdrawal operation
⊙ Withdrawal rate : 10th/min
접촉저항 : 50mΩ 이하
Contact Resistance: 50mΩ MAX
3-7.Terminal삽입력
3-7.InsertionForce ofTerminal
⊙ Housing을 고정시키고 Terminal를 25 ±3/min 속도로일직선으로 삽입할 때의 삽입력 측정
⊙ Insert a terminal into the housing straightly andmeasure insertion force
⊙ Velocity of insertion : 25 ±3mm/min
1.0Kgf 이하
1.0Kgf MAX
3-8.Terminal조립강도
3-8.TerminalRetentionForce
⊙ Housing에 Terminal을 조립한 후 Terminal을 25 ±3mm/min속도로 인장시켜 이탈될 때의 힘 측정
⊙ Insert a terminal into the housing and measurethe force to withdraw the terminal from housing.
⊙ Apply axial pull out force at the speed rate of25 ±3mm/minute
1.0Kgf 이상
1.0Kgf MIN
3-9.압착강도
3-9.CrimpTensileStrength
⊙ Terminal에 Lead Wire를 압착한후 압착부위(심선부위)가파괴될 때까지 25 ±3/min 속도로 인장강도 측정
⊙ Measured tensile strength of the crimped contact(stripped wire barrel section of contact) to conductor joint
AWG #16 : 4.0Kgf MIN
AWG #18 : 3.5Kgf MIN
AWG #20 : 3.0Kgf MIN
5 / 7
PRODUCT SPECIFICATION
Yeon Ho Electronics CO.,LTD
Y396 Series
NO.시험항목
『Test Title』시 험 방 법 및 조 건
『Test Procedures/Methods Conditions』규 격
『Requirements』
4. 환 경 시 험 『Environmental Test』
4-1.내진동성시 험
4-1.Vibration
⊙ DC 100mA 통전상태에서 진폭1.52mm 진동수 10-55-10HZ진동 상태에서 X,Y,Z방향으로 각각 2시간씩 진동을 시킨 후단전상태 및 접촉저항 측정
⊙ Current of 100mA shall be applied during the testingthe vibration shall be along each axis for theperiod of two hours with the maximum amplitude of1.52mm and frequency of 10-55-10Hz/Min(Based upon MIL-STD-202G Method 201A)
1)접촉저항: 50mΩ 이하2)단전상태: 1μsec동안 단전상태 없을것
1)Contact Resistance: 50mΩ MAX2)Discontinue: 1μsec MAX
4-2.염수분무시 험
4-2.Salt Spray
⊙ Connector를 결합한 상태에서 아래 조건으로 시험 후흐르는 물에 세척 후 상온에서 4시간 방치 후에 특성을측정한다.조건: 염수농도 5% ±1%
염수분무 시간 48시간 ±4시간(단,원자재: 2시간 적용함)시험온도 35 ±2
⊙ Measure after exposure to salt solution sprayof 5 ±1% density at a temperature of 35 ±2for 48hrs ±4hrs. (But, material apply to 2hrs)after test wash and leave to dry(Based upon MIL-STD-202G Method 101E Condition B)
1)접촉저항: 50mΩ 이하2)외관: 흑녹현상 없을것
1)Contact Resistance: 50mΩ MAX2)Appearance: Not black rust
4-3.내습성시험
4-3.Humidity
⊙ Connector를 결합한 상태에서 아래조건에 따라 시험을행한 후 측정한다.조건 : 시험조의 온도 40 ±2
상 대 습 도 90% ∼ 95%시 험 시 간 96시간
⊙ Mated connector shall be left for 96 hours in anenvironment of 40 ±2, and 90 ∼ 95% humidity.After the exposure the connector shall be left in an ambientcondition for one hour before the measurement is done(Based upon MIL-STD-202G Method 103B Condition B)
1)절연저항: 500 이상2)접촉저항: 50mΩ 이하3)외관 : 양호할 것
1)Insulation Resistance: 500 MIN2)Contact Resistance: 50mΩ MAX3)Appearance : Good
4-4.내고온성시 험
4-4.Resistanceto HighTemperature
⊙ Connector를 결합한 상태에서 시험조의 온도 85 ±2에서96시간 동안 시험 후 상온에서 30분간 방치 후 측정한다.
⊙ Chamber temperature : 85 ±2Exposed 30 minutes after being exposed 96 hoursunder the chamber temperature electricalcharacteristics were measured and tested(Based upon MIL-STD-202G Method 108A Condition A)
1)접촉저항: 50mΩ 이하
1)Contact Resistance: 50mΩ MAX
4-5.내한성시험
4-5.AltitudeLow Temperature
⊙ Connector를 결합한 상태에서 시험조의 온도 -40 ±3에서96시간 동안 시험 후 상온에서 30분간 방치 후 측정한다.
⊙ Chamber temperature : -40 ±3Exposed 30 minutes after being exposed 96 hoursunder the chamber temperature electricalcharacteristics were measured and tested(Based upon JIS C60068-2-1)
1)접촉저항: 50mΩ 이하
1)Contact Resistance: 50mΩ MAX
6 / 7
PRODUCT SPECIFICATION
Yeon Ho Electronics CO.,LTD
Y396 Series
6 . 포장 및 식별방법 『I d e n t i f i c a t i o n a n d P a c k i n g』
1) 포장 조건 『Packing Condition』: Bulk Packing
2) 포장 방법 『Packing Method』
충분한 강도의 종이 BOX를 사용하여 충격을 방지하여 물리적 변형 또는 화학적
변화가 발생되지 않도록 하여야 한다.
『Carton box for shipment must have enough strength in other to protect physical
damage during transportation.』
3) 식별 표시 : 다음과 같은 사항을 제품포장 BOX에 명기한다.
『Identifications shall be marked as follows』:
3-1. 제조 회사, 제조자명 또는 상표 『Manufacture's LOGO』
3-2. 형명 또는 부품번호 『Part Number』
3-3. 수 량 『Quantity』
3-4. 제조 LOT NO 『Date Code.』
3-5. 기타 상호 필요하다고 인정되는 사항
『Others agreed with manufacturer and customer』
7 / 7
NO.시험항목
『Test Title』
시 험 방 법 및 조 건
『Test Procedures/Methods Conditions』
규 격
『Requirements』
4-6.열충격시험
4-6.ThermalShock
⊙ Connector를 결합한 상태에서 아래조건에 따라 5회 연속시험을 행한 후 시험을 실시한다.
단 계 1 2 3 4
온도() -55 +0 25 +10 85 +3 25 +10-3 -5 -0 -5
시간(분) 30 5 30 5
⊙ Mated connector shall be exposed five cycles as table #1(Based upon MIL-STD-202G Method 107-A table #1)
STEP 1 2 3 4
Temperature () -55 +0 25 +10 85 +3 25 +10-3 -5 -0 -5
Exposed Time (MIN) 30 5 30 5
1)내전압: 절연파괴 및섬락이 없고 사용상결함이 없을 것
2)접촉저항: 50mΩ 이하3)절연저항: 500 이상4)외관 : 양호할 것
1)Dielectric Strength: No flash over andno physical damageshall be observed
2)Contact Resistance: 50mΩ MAX3)Insulation Resistance: 500 MIN4)Appearance : Good
PRODUCT SPECIFICATION
Yeon Ho Electronics CO.,LTD
Y396 Series
7. 사용상 주의사항 『Caution for Use』
본 connector는 강(强)Lock 사양이므로, Connector 감합후의 Wire Harness의 부정확한
취급방향이나 과도하게 잡아당길 경우에는 납땜부의 파괴, Lock등 Connector자체의 파괴
또는 실장기판의 파괴등 Trouble를 발생시킬 가능성이 있습니다.
이와 같은 Trouble을 미연에 방지하고, Connector 성능을 충분히 내기 위해서는,
Wire Harness를 취급할 때 다음과 같은 주의를 바랍니다.
『This connector is secure lock type, so the connector must be treated with care after
mated. Incorrect handling direction and excessive pulling load to the wire harness
may cause troubles which affect its performances such as degradation at solder tail,
breakage of connector itself (lock devise, etc.) and a PCB for mounting. To prevent
these troubles and make full use of connector's performances, special care should be
taken on the following points when handling the wire harness.』
1) Connector에는 평소 Wire Harness 취급할 때, 인장하중 이외에 외력을 지속적으로 가하지
않는다.
『Do not apply an external force to a connector continuously except forpulling load and so on when handling wire harness as usual.』
2) 전선에는 Connector의 삽발작업이 무리없이 이루어 질 수 있도록 “느슨하게”설계하고
삽발작업은 감합축 선으로 한다.
『For the wire, make an appropriate looseness to mate and unmate theconnector on the mating axis without strain.』
3) Connector에서 Wire Harness를 분리할 때에는 Lock을 완전히 해제하고 발거한다.
『When withdraw wire harness from the connector, Lock should be unlocked perfectlyand withdraw.』
INSPECTION DATA안안안안안안안안안안안안안안안안안안안안안안안안안안안안안안안안안안안안안안안안안안안안안안
A
P
P`
R
Writ`N CHK`D APR`D
L.J.H Y.M.K C.G.N
DESCRIPTION CONNECTOR MODEL NO YH396-03BR(RE) TEST CONDITION Temp:22,Humid:65%
Test Title Test Procedures Specification X1 X2 X3 X4 X5 Conclusion
1-1.InsulationResistance
쐕Test voltage : DC 500V±5V쐕Electrification time : 1minute 1000 MIN 1000 MIN GOOD
1-2.DielectricWithstandingVoltage
쐕Test voltage : AC 1500V쐕Electrification time : 1minute No damage O.K O.K O.K O.K O.K GOOD
1-3.ContactResistance
쐕Measured the resistance ofmated connector, 20mV. 10mA 30mΩ MAX 6.5 6.8 6.7 6.9 7.0 GOOD
2-1.Solder Ability 쐕SnAgCu 240±5, 3±0.5sec 90% MIN O.K O.K O.K O.K O.K GOOD
2-2.Solder HeatResistance 쐕260±5, 5±0.5sec GOOD O.K O.K O.K O.K O.K GOOD
2-3.PinRetention Force
쐕Measured withdrawal force thatresin grips and supports pin 1.0Kgf MIN 5.32 5.14 5.21 5.25 5.42 GOOD
2-4.TotalInsertion Force
쐕Measured forces to insert waferass'y into the housing ass'ywhich has same circuits
3.50Kgf MAX 1.14 1.25 1.17 1.20 1.28 GOOD
2-5.TotalWithdrawal Force
쐕Measured forces to withdrawwafer ass'y from the housingass'y which has same circuits(Un Locking)
0.15Kgf MIN 0.64 0.72 0.61 0.65 0.68 GOOD
2-6.Durabilityof ContactResistance
쐕Measured contact resistanceafter 30 cycles of total insertionand withdrawal operation.
ContactResistance :50mΩ MAX
7.2 7.0 6.8 6.7 6.9 GOOD
2-7.InsertionForce of Terminal
쐕Insert a terminal into the housingstraightly and measure insertion force 1.0Kgf MAX 0.50 0.52 0.55 0.51 0.52 GOOD
2-8.TerminalRetentionForce
쐕Insert a terminal into the housing andmeasure the force to withdraw theterminal from housing.
1.0Kgf MIN 4.24 4.60 4.32 4.37 4.45 GOOD
2-9.CrimpTensile Strength
쐕 Measured tensile strength of thecrimped contact to conductor joint AWG #22: 2.5Kgf MIN 6.34 6.42 6.27 6.52 6.38 GOOD
3-1.Vibration 쐕 100mA, 1.52mm, 10-55-10Hz 2hrs
ContactResistance 50mΩ MAX 7.2 6.8 7.0 7.1 6.7 GOOD
Discontinue 1μsec MAX O.K O.K O.K O.K O.K GOOD
3-2.Salt Spray
쐕Salt solution : 5±1%쐕Exposed time : 48hrs ±4hrs(Material : 2hrs)
쐕Temperature : 35±2
ContactResistance 50mΩ MAX 7.7 8.0 7.5 7.8 7.7 GOOD
Appearance Not blackrust O.K O.K O.K O.K O.K GOOD
3-3.Humidity쐕Chamber temperature: 40±2쐕Relative humidity : 90∼95%쐕Duration : 96hrs
InsulationResistance 500 MIN 500 MIN GOOD
ContactResistance 50mΩ MAX 7.1 7.3 7.5 7.2 7.4 GOOD
Appearance Good O.K O.K O.K O.K O.K GOOD
3-4.Resistanceto High Temper
쐕Chamber temperature : 85±2쐕Exposed time : 96hrs
ContactResistance 50mΩ MAX 7.3 6.8 7.1 7.2 6.9 GOOD
3-5.AltitudeLow Temperature
쐕Chamber temperature: -40±3쐕Exposed time : 96hrs
ContactResistance 50mΩ MAX 7.0 7.2 6.8 7.1 6.9 GOOD
3-6.ThermalShock
쐕1 Cycle is table #1쐕After performing 5 cycles
STEP 1 2 3 4
Temperature()
-55+025+10
85+325+10
-3 -5 -0 -5Exposed Time(MIN)
30 5 30 5
DielectricStrength No damage O.K O.K O.K O.K O.K GOOD
ContactResistance 50mΩ MAX 7.3 7.5 7.6 7.3 7.1 GOOD
InsulationResistance 500 MIN 500 MIN GOOD
Appearance Good O.K O.K O.K O.K O.K GOOD
Page 1 of 4Issued Date: 2012. 10. 23Test Report No. F690101/LF-CTSAYAA12-37431
YEONHO ELECTRONICS CO., LTD.#506-2Hanam-dongGwangsan-guGwangju KOREA
To:
The following merchandise was submitted and identified by the client as :
SGS File No. : AYAA12-37431
Product Name : PA66 2413 GW NC
Item No./Part No. : N/A
2012. 10. 18
2012. 10. 23to2012. 10. 19
Received Date :
Test Period :
Test Results : For further details, please refer to following page(s)
Test Performed : SGS Korea tested the sample(s) selected by applicant with following results.
SGS Korea Co. Ltd.
Jeff Jang / Chemical Lab Mgr
Timothy Jeon Jinhee Kim Cindy Park Jerry Jung/ Testing Person
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
Member of the SGS Group (Société Générale de Surveillance)
322, The O valley, 555-9, Hogye-dong, Dongan-gu, Anyang-si, Gyeonggi-do, Korea 431-080 t +82 (0)31 4608 000 f +82 (0)31 4608 059 http://www.sgslab.co.kr ,www.kr.sgs.com/greenlabSGS Korea Co.,Ltd.
F052 Version5
Page 2 of 4Issued Date: 2012. 10. 23Test Report No. F690101/LF-CTSAYAA12-37431
Sample No. : AYAA12-37431.001
PA66 2413 GW NCSample Description :
Item No./Part No. : N/A
N/AMaterials :
Heavy Metals
ResultsMDLTest MethodUnitTest Items
0.5With reference to IEC 62321:2008, ICPCadmium (Cd) N.D.mg/kg
5With reference to IEC 62321:2008, ICPLead (Pb) N.D.mg/kg
2With reference to IEC 62321:2008, ICPMercury (Hg) N.D.mg/kg
1With reference to IEC 62321:2008, UV-VISHexavalent Chromium (Cr VI) N.D.mg/kg
Flame Retardants-PBBs/PBDEs
ResultsMDLTest MethodUnitTest Items
5With reference to IEC 62321:2008, GC-MSMonobromobiphenyl N.D.mg/kg
5With reference to IEC 62321:2008, GC-MSDibromobiphenyl N.D.mg/kg
5With reference to IEC 62321:2008, GC-MSTribromobiphenyl N.D.mg/kg
5With reference to IEC 62321:2008, GC-MSTetrabromobiphenyl N.D.mg/kg
5With reference to IEC 62321:2008, GC-MSPentabromobiphenyl N.D.mg/kg
5With reference to IEC 62321:2008, GC-MSHexabromobiphenyl N.D.mg/kg
5With reference to IEC 62321:2008, GC-MSHeptabromobiphenyl N.D.mg/kg
5With reference to IEC 62321:2008, GC-MSOctabromobiphenyl N.D.mg/kg
5With reference to IEC 62321:2008, GC-MSNonabromobiphenyl N.D.mg/kg
5With reference to IEC 62321:2008, GC-MSDecabromobiphenyl N.D.mg/kg
5With reference to IEC 62321:2008, GC-MSMonobromodiphenyl ether N.D.mg/kg
5With reference to IEC 62321:2008, GC-MSDibromodiphenyl ether N.D.mg/kg
5With reference to IEC 62321:2008, GC-MSTribromodiphenyl ether N.D.mg/kg
5With reference to IEC 62321:2008, GC-MSTetrabromodiphenyl ether N.D.mg/kg
5With reference to IEC 62321:2008, GC-MSPentabromodiphenyl ether N.D.mg/kg
5With reference to IEC 62321:2008, GC-MSHexabromodiphenyl ether N.D.mg/kg
5With reference to IEC 62321:2008, GC-MSHeptabromodiphenyl ether N.D.mg/kg
5With reference to IEC 62321:2008, GC-MSOctabromodiphenyl ether N.D.mg/kg
5With reference to IEC 62321:2008, GC-MSNonabromodiphenyl ether N.D.mg/kg
5With reference to IEC 62321:2008, GC-MSDecabromodiphenyl ether N.D.mg/kg
NOTE:(1) N.D. = Not detected.(<MDL)(2) mg/kg = ppm(3) MDL = Method Detection Limit(4) - = No regulation(5) Negative = Undetectable / Positive = Detectable(6) ** = Qualitative analysis (No Unit)(7) * = Boiling-water-extraction: Negative = Absence of CrVI coating Positive = Presence of CrVI coating; the detected concentration in boiling-water-extraction solution is equal or greater than 0.02 mg/kg with 50 cm2 sample surface area.
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
Member of the SGS Group (Société Générale de Surveillance)
322, The O valley, 555-9, Hogye-dong, Dongan-gu, Anyang-si, Gyeonggi-do, Korea 431-080 t +82 (0)31 4608 000 f +82 (0)31 4608 059 http://www.sgslab.co.kr ,www.kr.sgs.com/greenlabSGS Korea Co.,Ltd.
F052 Version5
Page 3 of 4Issued Date: 2012. 10. 23Test Report No. F690101/LF-CTSAYAA12-37431
Picture of Sample as Received:
NOTE:(1) N.D. = Not detected.(<MDL)(2) mg/kg = ppm(3) MDL = Method Detection Limit(4) - = No regulation(5) Negative = Undetectable / Positive = Detectable(6) ** = Qualitative analysis (No Unit)(7) * = Boiling-water-extraction: Negative = Absence of CrVI coating Positive = Presence of CrVI coating; the detected concentration in boiling-water-extraction solution is equal or greater than 0.02 mg/kg with 50 cm2 sample surface area.
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
Member of the SGS Group (Société Générale de Surveillance)
322, The O valley, 555-9, Hogye-dong, Dongan-gu, Anyang-si, Gyeonggi-do, Korea 431-080 t +82 (0)31 4608 000 f +82 (0)31 4608 059 http://www.sgslab.co.kr ,www.kr.sgs.com/greenlabSGS Korea Co.,Ltd.
F052 Version5
Page 4 of 4Issued Date: 2012. 10. 23Test Report No. F690101/LF-CTSAYAA12-37431
Testing Flow Chart for RoHS:Cd/Pb/Hg/Cr6+ /PBBs&PBDEs Testing
Sample Measurement
DATA
GC/MS
Solvent Extraction of the Sample
Clean-up with Florisil Column
Concentration/Dilution of Extraction Solution
Filtration
Cd/Pb/Hg PBBs/PBDEs
Mechanic_Sample
Sample Measurement
Acid Digestion with Microwave/Hotplate
Filtration
Residue
Total Digestion
ICP-AES/AAS/MS
DATA
Mechanic_Sample
A Red Color Indicates the Presence of CrVI
Confirmwith UV-Vis
Cr
Sample Measurement
Adding Extraction Solution
Metallic Material
UV-Vis
DATA
Mechanic_Sample
6+
Filtration and pH Adjustment
Adding 1,5-Diphenylcarbazidefor Color Development
Heating to 90~95°C for Extraction
Nonmetallic Material
Adding 1,5-Diphenylcarbazide
for Color Development
Mechanic_Sample
Sample Measurement
Spot Test / Boiling Water Extraction
DATA
Cr6+
The samples were dissolved totally by pre-conditioning method according to above flow chart for Cd,Pb,Hg. Section Chief : Gilsae Yi
*** End ***
NOTE:(1) N.D. = Not detected.(<MDL)(2) mg/kg = ppm(3) MDL = Method Detection Limit(4) - = No regulation(5) Negative = Undetectable / Positive = Detectable(6) ** = Qualitative analysis (No Unit)(7) * = Boiling-water-extraction: Negative = Absence of CrVI coating Positive = Presence of CrVI coating; the detected concentration in boiling-water-extraction solution is equal or greater than 0.02 mg/kg with 50 cm2 sample surface area.
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
Member of the SGS Group (Société Générale de Surveillance)
322, The O valley, 555-9, Hogye-dong, Dongan-gu, Anyang-si, Gyeonggi-do, Korea 431-080 t +82 (0)31 4608 000 f +82 (0)31 4608 059 http://www.sgslab.co.kr ,www.kr.sgs.com/greenlabSGS Korea Co.,Ltd.
F052 Version5
This Test Report is issued by the Company subject to its Terms and Conditions of Business printed overleaf. Attention is drawn to the limitations of liability, indemnification and jurisdictional issues defined therein. This Test Report shall not be reproduced, except in full, without prior written consent of the Company.
Intertek Testing Services Korea Ltd.
Seoul Office: Tel : 02-6090-9500 Fax : 02-3409-0026 Daegu Office : Tel : 053-600-8647 Fax : 053-600-8645 Web Site : www.Intertek.co.kr Seoul Lab. Address : 1/F, A-ju Digital Tower, #284-56, Seongsu 2-ga, Seongdong-Gu, Seoul, 133-833 Korea
Ulsan Lab. Address : #340-2, Yongam-Ri, Chongryang-Myun, Ulju-Gun, Ulsan 689-865 Korea
TEST REPORTTEST REPORTTEST REPORTTEST REPORT
Applicant : LG Chem. Ltd. Iksan Plant
Address : #599, Yongjei-dong, Iksan-si,
Jeollabuk-do, 570-350 Korea
Page: 1 of 6
Report No. RT12R-U2320-005-E Date: Dec. 14, 2012
Sample Description : The following submitted sample(s) said to be:-
Name/Type of Product : LUMID GN1001BF-R0090
Sample ID No. : RT12R-U2320-005
Manufacturer/Vender : LG Chem. Ltd. Iksan Plant
Sample received : Dec. 12, 2012
Testing Date : Dec. 12, 2012 ~ Dec. 14, 2012
Test Type : RoHS wet chemical analysis
Test Method(s) : Please see the following page(s).
Test Result(s) : Please see the following page(s).
* Note 1 : The test results presented in this report relate only to the object tested.
* Note 2 : This report shall not be reproduced except in full without the written approval of the testing laboratory.
Approved by, Authorized by,
E.Y.Lee / Lab. Technical Manager H.W.Yoo / Lab. General Manager
This Test Report is issued by the Company subject to its Terms and Conditions of Business printed overleaf. Attention is drawn to the limitations of liability, indemnification and jurisdictional issues defined therein. This Test Report shall not be reproduced, except in full, without prior written consent of the Company.
Intertek Testing Services Korea Ltd.
Seoul Office: Tel : 02-6090-9500 Fax : 02-3409-0026 Daegu Office : Tel : 053-600-8647 Fax : 053-600-8645 Web Site : www.Intertek.co.kr Seoul Lab. Address : 1/F, A-ju Digital Tower, #284-56, Seongsu 2-ga, Seongdong-Gu, Seoul, 133-833 Korea
Ulsan Lab. Address : #340-2, Yongam-Ri, Chongryang-Myun, Ulju-Gun, Ulsan 689-865 Korea
TEST REPORTTEST REPORTTEST REPORTTEST REPORT Page: 2 of 6
Report No. RT12R-U2320-005-E Date: Dec. 14, 2012
Sample ID No. : RT12R-U2320-005
Sample Description : LUMID GN1001BF-R0090
Test Item Unit Test Method MDL Result
Cadmium (Cd) / 0.5 N.D.
Lead (Pb) / 5 N.D.
Mercury (Hg) /
With reference to IEC 62321 Edition 1.0:2008,
by acid digestion and determined by ICP-OES 2 N.D.
Hexavalent Chromium (Cr 6+
) (For non-metal)
/
With reference to IEC 62321 Edition 1.0:2008, by alkaline digestion and
determined by UV-VIS Spectrophotometer
1 N.D.
Polybrominated Biphenyl (PBBs)
Monobromobiphenyl / 5 N.D.
Dibromobiphenyl / 5 N.D.
Tribromobiphenyl / 5 N.D.
Tetrabromobiphenyl / 5 N.D.
Pentabromobiphenyl / 5 N.D.
Hexabromobiphenyl / 5 N.D.
Heptabromobiphenyl / 5 N.D.
Octabromobiphenyl / 5 N.D.
Nonabromobiphenyl / 5 N.D.
Decabromobiphenyl /
With reference to IEC 62321 Edition 1.0:2008, by solvent extraction and
determined by GC/MS
5 N.D.
Polybrominated Diphenyl Ether (PBDEs)
Monobromodiphenyl ether / 5 N.D.
Dibromodiphenyl ether / 5 N.D.
Tribromodiphenyl ether / 5 N.D.
Tetrabromodiphenyl ether / 5 N.D.
Pentabromodiphenyl ether / 5 N.D.
Hexabromodiphenyl ether / 5 N.D.
Heptabromodiphenyl ether / 5 N.D.
Octabromodiphenyl ether / 5 N.D.
Nonabromodiphenyl ether / 5 N.D.
Decabromodiphenyl ether /
With reference to IEC 62321 Edition 1.0:2008, by solvent extraction and
determined by GC/MS
5 N.D.
Tested by : YK Cho, HJ Kim, MB Song Notes : / = ppm = parts per million
< = Less than N.D. = Not detected ( <MDL )
MDL = Method detection limit
This Test Report is issued by the Company subject to its Terms and Conditions of Business printed overleaf. Attention is drawn to the limitations of liability, indemnification and jurisdictional issues defined therein. This Test Report shall not be reproduced, except in full, without prior written consent of the Company.
Intertek Testing Services Korea Ltd.
Seoul Office: Tel : 02-6090-9500 Fax : 02-3409-0026 Daegu Office : Tel : 053-600-8647 Fax : 053-600-8645 Web Site : www.Intertek.co.kr Seoul Lab. Address : 1/F, A-ju Digital Tower, #284-56, Seongsu 2-ga, Seongdong-Gu, Seoul, 133-833 Korea
Ulsan Lab. Address : #340-2, Yongam-Ri, Chongryang-Myun, Ulju-Gun, Ulsan 689-865 Korea
TEST REPORTTEST REPORTTEST REPORTTEST REPORT Page: 3 of 6
Report No. RT12R-U2320-005-E Date: Dec. 14, 2012
Sample ID No. : RT12R-U2320-005
Sample Description : LUMID GN1001BF-R0090
Test Item Unit Test Method MDL Result
Antimony (Sb) / With reference to US EPA
3052, by acid digestion and determined by ICP-OES
2 150
Bromine (Br) / With reference to EN 14582, by oxygen combustion with bomb and determined by IC
30 N.D.
Chlorine (Cl) / With reference to EN 14582, by oxygen combustion with bomb and determined by IC
30 N.D.
Tested by : YK Cho
Notes : / = ppm = parts per million
< = Less than
N.D. = Not detected ( <MDL )
MDL = Method detection limit
* View of sample as received;-
This Test Report is issued by the Company subject to its Terms and Conditions of Business printed overleaf. Attention is drawn to the limitations of liability, indemnification and jurisdictional issues defined therein. This Test Report shall not be reproduced, except in full, without prior written consent of the Company.
Intertek Testing Services Korea Ltd.
Seoul Office: Tel : 02-6090-9500 Fax : 02-3409-0026 Daegu Office : Tel : 053-600-8647 Fax : 053-600-8645 Web Site : www.Intertek.co.kr Seoul Lab. Address : 1/F, A-ju Digital Tower, #284-56, Seongsu 2-ga, Seongdong-Gu, Seoul, 133-833 Korea
Ulsan Lab. Address : #340-2, Yongam-Ri, Chongryang-Myun, Ulju-Gun, Ulsan 689-865 Korea
TEST REPORTTEST REPORTTEST REPORTTEST REPORT Page: 4 of 6
Report No. RT12R-U2320-005-E Date: Dec. 14, 2012
Sample ID No. : RT12R-U2320-005
Sample Description : LUMID GN1001BF-R0090
Remarks :
*1 : List of appropriate acid:
Material Acid added for digestion
Polymers HNO3, HCl, HF, H2O2, H3BO3
Metals HNO3, HCl, HF
Electronics HNO3, HCl, H2O2, HBF4
*2 : The samples were dissolved totally by pre-conditioning method according to above flow chart.
This Test Report is issued by the Company subject to its Terms and Conditions of Business printed overleaf. Attention is drawn to the limitations of liability, indemnification and jurisdictional issues defined therein. This Test Report shall not be reproduced, except in full, without prior written consent of the Company.
Intertek Testing Services Korea Ltd.
Seoul Office: Tel : 02-6090-9500 Fax : 02-3409-0026 Daegu Office : Tel : 053-600-8647 Fax : 053-600-8645 Web Site : www.Intertek.co.kr Seoul Lab. Address : 1/F, A-ju Digital Tower, #284-56, Seongsu 2-ga, Seongdong-Gu, Seoul, 133-833 Korea
Ulsan Lab. Address : #340-2, Yongam-Ri, Chongryang-Myun, Ulju-Gun, Ulsan 689-865 Korea
TEST REPORTTEST REPORTTEST REPORTTEST REPORT Page: 5 of 6
Report No. RT12R-U2320-005-E Date: Dec. 14, 2012
Sample ID No. : RT12R-U2320-005
Sample Description : LUMID GN1001BF-R0090
** Remarks : The samples were dissolved totally by pre-conditioning method according to above flow chart.
This Test Report is issued by the Company subject to its Terms and Conditions of Business printed overleaf. Attention is drawn to the limitations of liability, indemnification and jurisdictional issues defined therein. This Test Report shall not be reproduced, except in full, without prior written consent of the Company.
Intertek Testing Services Korea Ltd.
Seoul Office: Tel : 02-6090-9500 Fax : 02-3409-0026 Daegu Office : Tel : 053-600-8647 Fax : 053-600-8645 Web Site : www.Intertek.co.kr Seoul Lab. Address : 1/F, A-ju Digital Tower, #284-56, Seongsu 2-ga, Seongdong-Gu, Seoul, 133-833 Korea
Ulsan Lab. Address : #340-2, Yongam-Ri, Chongryang-Myun, Ulju-Gun, Ulsan 689-865 Korea
TEST REPORTTEST REPORTTEST REPORTTEST REPORT Page: 6 of 6
Report No. RT12R-U2320-005-E Date: Dec. 14, 2012
Sample ID No. : RT12R-U2320-005
Sample Description : LUMID GN1001BF-R0090
***** End of Report *****
This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct.
Page 1 of 6Issued Date: 2013. 01. 02Test Report No. F690101/LF-CTSAYAA12-46252
YEONHO ELECTRONICS CO., LTD.#506-2Hanam-dongGwangsan-guGwangju KOREA
To:
The following merchandise was submitted and identified by the client as :
SGS File No. : AYAA12-46252
Product Name : PA66 2413 GW2 RE
Item No./Part No. : N/A
2012. 12. 27
2013. 01. 02to2012. 12. 28
Received Date :
Test Period :
Test Results : For further details, please refer to following page(s)
Test Performed : SGS Korea tested the sample(s) selected by applicant with following results.
Timothy Jeon Jinhee Kim Cindy Park Jerry Jung/ Testing Person Jeff Jang / Chemical Lab Mgr
SGS Korea Co., Ltd.
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
Member of the SGS Group (Société Générale de Surveillance)
322, The O valley, 555-9, Hogye-dong, Dongan-gu, Anyang-si, Gyeonggi-do, Korea 431-080 t +82 (0)31 4608 000 f +82 (0)31 4608 059 http://www.sgslab.co.kr ,www.kr.sgs.com/greenlabSGS Korea Co.,Ltd.
F052 Version5
Page 2 of 6Issued Date: 2013. 01. 02Test Report No. F690101/LF-CTSAYAA12-46252
Sample No. : AYAA12-46252.001
PA66 2413 GW2 RESample Description :
Item No./Part No. : N/A
N/AMaterials :
Heavy Metals
ResultsMDLTest MethodUnitTest Items
0.5With reference to IEC 62321:2008, ICPCadmium (Cd) N.D.mg/kg
5With reference to IEC 62321:2008, ICPLead (Pb) N.D.mg/kg
2With reference to IEC 62321:2008, ICPMercury (Hg) N.D.mg/kg
1With reference to IEC 62321:2008, UV-VISHexavalent Chromium (Cr VI) N.D.mg/kg
10With reference to EPA 3052(1996), US EPA 6010B(1996), ICP
Antimony (Sb) 63800mg/kg
Flame Retardants-PBBs/PBDEs
ResultsMDLTest MethodUnitTest Items
5With reference to IEC 62321:2008, GC-MSMonobromobiphenyl N.D.mg/kg
5With reference to IEC 62321:2008, GC-MSDibromobiphenyl N.D.mg/kg
5With reference to IEC 62321:2008, GC-MSTribromobiphenyl N.D.mg/kg
5With reference to IEC 62321:2008, GC-MSTetrabromobiphenyl N.D.mg/kg
5With reference to IEC 62321:2008, GC-MSPentabromobiphenyl N.D.mg/kg
5With reference to IEC 62321:2008, GC-MSHexabromobiphenyl N.D.mg/kg
5With reference to IEC 62321:2008, GC-MSHeptabromobiphenyl N.D.mg/kg
5With reference to IEC 62321:2008, GC-MSOctabromobiphenyl N.D.mg/kg
5With reference to IEC 62321:2008, GC-MSNonabromobiphenyl N.D.mg/kg
5With reference to IEC 62321:2008, GC-MSDecabromobiphenyl N.D.mg/kg
5With reference to IEC 62321:2008, GC-MSMonobromodiphenyl ether N.D.mg/kg
5With reference to IEC 62321:2008, GC-MSDibromodiphenyl ether N.D.mg/kg
5With reference to IEC 62321:2008, GC-MSTribromodiphenyl ether N.D.mg/kg
5With reference to IEC 62321:2008, GC-MSTetrabromodiphenyl ether N.D.mg/kg
5With reference to IEC 62321:2008, GC-MSPentabromodiphenyl ether N.D.mg/kg
5With reference to IEC 62321:2008, GC-MSHexabromodiphenyl ether N.D.mg/kg
5With reference to IEC 62321:2008, GC-MSHeptabromodiphenyl ether N.D.mg/kg
5With reference to IEC 62321:2008, GC-MSOctabromodiphenyl ether N.D.mg/kg
NOTE:(1) N.D. = Not detected.(<MDL)(2) mg/kg = ppm(3) MDL = Method Detection Limit(4) - = No regulation(5) Negative = Undetectable / Positive = Detectable(6) ** = Qualitative analysis (No Unit)(7) * = Boiling-water-extraction: Negative = Absence of CrVI coating Positive = Presence of CrVI coating; the detected concentration in boiling-water-extraction solution is equal or greater than 0.02 mg/kg with 50 cm2 sample surface area.
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
Member of the SGS Group (Société Générale de Surveillance)
322, The O valley, 555-9, Hogye-dong, Dongan-gu, Anyang-si, Gyeonggi-do, Korea 431-080 t +82 (0)31 4608 000 f +82 (0)31 4608 059 http://www.sgslab.co.kr ,www.kr.sgs.com/greenlabSGS Korea Co.,Ltd.
F052 Version5
Page 3 of 6Issued Date: 2013. 01. 02Test Report No. F690101/LF-CTSAYAA12-46252
Sample No. : AYAA12-46252.001
PA66 2413 GW2 RESample Description :
Item No./Part No. : N/A
N/AMaterials :
Flame Retardants-PBBs/PBDEs
ResultsMDLTest MethodUnitTest Items
5With reference to IEC 62321:2008, GC-MSNonabromodiphenyl ether N.D.mg/kg
5With reference to IEC 62321:2008, GC-MSDecabromodiphenyl ether N.D.mg/kg
Halogen Content
ResultsMDLTest MethodUnitTest Items
30BS EN 14582:2007 , ICBromine(Br) 77500mg/kg
30BS EN 14582:2007 , ICChlorine(Cl) 1560mg/kg
NOTE:(1) N.D. = Not detected.(<MDL)(2) mg/kg = ppm(3) MDL = Method Detection Limit(4) - = No regulation(5) Negative = Undetectable / Positive = Detectable(6) ** = Qualitative analysis (No Unit)(7) * = Boiling-water-extraction: Negative = Absence of CrVI coating Positive = Presence of CrVI coating; the detected concentration in boiling-water-extraction solution is equal or greater than 0.02 mg/kg with 50 cm2 sample surface area.
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
Member of the SGS Group (Société Générale de Surveillance)
322, The O valley, 555-9, Hogye-dong, Dongan-gu, Anyang-si, Gyeonggi-do, Korea 431-080 t +82 (0)31 4608 000 f +82 (0)31 4608 059 http://www.sgslab.co.kr ,www.kr.sgs.com/greenlabSGS Korea Co.,Ltd.
F052 Version5
Page 4 of 6Issued Date: 2013. 01. 02Test Report No. F690101/LF-CTSAYAA12-46252
Picture of Sample as Received:
NOTE:(1) N.D. = Not detected.(<MDL)(2) mg/kg = ppm(3) MDL = Method Detection Limit(4) - = No regulation(5) Negative = Undetectable / Positive = Detectable(6) ** = Qualitative analysis (No Unit)(7) * = Boiling-water-extraction: Negative = Absence of CrVI coating Positive = Presence of CrVI coating; the detected concentration in boiling-water-extraction solution is equal or greater than 0.02 mg/kg with 50 cm2 sample surface area.
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
Member of the SGS Group (Société Générale de Surveillance)
322, The O valley, 555-9, Hogye-dong, Dongan-gu, Anyang-si, Gyeonggi-do, Korea 431-080 t +82 (0)31 4608 000 f +82 (0)31 4608 059 http://www.sgslab.co.kr ,www.kr.sgs.com/greenlabSGS Korea Co.,Ltd.
F052 Version5
Page 5 of 6Issued Date: 2013. 01. 02Test Report No. F690101/LF-CTSAYAA12-46252
Testing Flow Chart for RoHS:Cd/Pb/Hg/Cr6+ /PBBs&PBDEs Testing
Sample Measurement
DATA
GC/MS
Solvent Extraction of the Sample
Clean-up with Florisil Column
Concentration/Dilution of Extraction Solution
Filtration
Cd/Pb/Hg PBBs/PBDEs
Mechanic_Sample
Sample Measurement
Acid Digestion with Microwave/Hotplate
Filtration
Residue
Total Digestion
ICP-AES/AAS/MS
DATA
Mechanic_Sample
A Red Color Indicates the Presence of CrVI
Confirmwith UV-Vis
Cr
Sample Measurement
Adding Extraction Solution
Metallic Material
UV-Vis
DATA
Mechanic_Sample
6+
Filtration and pH Adjustment
Adding 1,5-Diphenylcarbazidefor Color Development
Heating to 90~95°C for Extraction
Nonmetallic Material
Adding 1,5-Diphenylcarbazide
for Color Development
Mechanic_Sample
Sample Measurement
Spot Test / Boiling Water Extraction
DATA
Cr6+
The samples were dissolved totally by pre-conditioning method according to above flow chart for Cd,Pb,Hg. Section Chief : Gilsae Yi
NOTE:(1) N.D. = Not detected.(<MDL)(2) mg/kg = ppm(3) MDL = Method Detection Limit(4) - = No regulation(5) Negative = Undetectable / Positive = Detectable(6) ** = Qualitative analysis (No Unit)(7) * = Boiling-water-extraction: Negative = Absence of CrVI coating Positive = Presence of CrVI coating; the detected concentration in boiling-water-extraction solution is equal or greater than 0.02 mg/kg with 50 cm2 sample surface area.
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
Member of the SGS Group (Société Générale de Surveillance)
322, The O valley, 555-9, Hogye-dong, Dongan-gu, Anyang-si, Gyeonggi-do, Korea 431-080 t +82 (0)31 4608 000 f +82 (0)31 4608 059 http://www.sgslab.co.kr ,www.kr.sgs.com/greenlabSGS Korea Co.,Ltd.
F052 Version5
Page 6 of 6Issued Date: 2013. 01. 02Test Report No. F690101/LF-CTSAYAA12-46252
Flow Chart for Halogen Test
Weigh the samples into the combustion boat.
Analyze absorbed solution using Ion Chromatography.
Admit O2 gas or O2 +Ar2 gas and start the combustion.
Add absorption solution into the bomb or tube.
Sample screening using XRF.
Liquid containing water(>80%)?
Dilute the solution
(EPA300)
No
Yes
Allow during absorption of the burnt gas.
Data
*** End ***
NOTE:(1) N.D. = Not detected.(<MDL)(2) mg/kg = ppm(3) MDL = Method Detection Limit(4) - = No regulation(5) Negative = Undetectable / Positive = Detectable(6) ** = Qualitative analysis (No Unit)(7) * = Boiling-water-extraction: Negative = Absence of CrVI coating Positive = Presence of CrVI coating; the detected concentration in boiling-water-extraction solution is equal or greater than 0.02 mg/kg with 50 cm2 sample surface area.
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
Member of the SGS Group (Société Générale de Surveillance)
322, The O valley, 555-9, Hogye-dong, Dongan-gu, Anyang-si, Gyeonggi-do, Korea 431-080 t +82 (0)31 4608 000 f +82 (0)31 4608 059 http://www.sgslab.co.kr ,www.kr.sgs.com/greenlabSGS Korea Co.,Ltd.
F052 Version5
Page 1 of 3Issued Date: 2012. 10. 30Test Report No. F690101/LF-CTSAYAU12-05925
POONGSAN CORPORATION
611 Daejung-ri,
Onsan-eup,
Ulju,
Ulsan
Korea
To:
The following merchandise was submitted and identified by the client as :
SGS File No. : AYAU12-05925
Product Name : C2700
Item No./Part No. : Brass
2012. 10. 25
2012. 10. 30to2012. 10. 26
Received Date :
Test Period :
Test Results : For further details, please refer to following page(s)
Test Performed : SGS Korea tested the sample(s) selected by applicant with following results.
Conclusion : Based on the performed tests on submitted sample(s), the results comply with the RoHS
Directive 2002/95/EC and its subsequent amendments.
SGS Korea Co., Ltd. / Gimhae Laboratory
Thomas Hwang / Gimhae Lab. Mgr
Sharpless Park
Jonadan Lee
Taehee Kang
Jongsir Lim/Testing Person
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at
www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if
any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration,
forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
F055 Version5 SGS Korea Co.,Ltd.
204, GBMC, 155-1, Nongso-ri, Juchon-myeon, Gimhae-si, Gyeongnam, Korea 621-842
t +82 (0)55 3108 800 f +82 (0)55 3108 809 http://www.sgslab.co.kr , www.kr.sgs.com/greenlab
Page 2 of 3Issued Date: 2012. 10. 30Test Report No. F690101/LF-CTSAYAU12-05925
Sample No. : AYAU12-05925.001
C2700Sample Description :
Item No./Part No. : Brass
N/AMaterials :
Heavy Metals
Test Items Unit Test Method MDL Results
1With reference to IEC 62321:2008, ICPCadmium (Cd) N.D.mg/kg
5With reference to IEC 62321:2008, ICPLead (Pb) 35mg/kg
2With reference to IEC 62321:2008, ICPMercury (Hg) N.D.mg/kg
-With reference to IEC 62321:2008Hexavalent Chromium (Cr VI) By boiling
water extraction*
Negative**
Picture of Sample as Received:
NOTE: (1) N.D. = Not detected.(<MDL)
(2) mg/kg = ppm
(3) MDL = Method Detection Limit
(4) - = No regulation
(5) Negative = Undetectable / Positive = Detectable
(6) ** = Qualitative analysis (No Unit)
(7) * = Boiling-water-extraction:
Negative = Absence of CrVI coating
Positive = Presence of CrVI coating; the detected concentration in boiling-water-extraction
solution is equal or greater than 0.02 mg/kg with 50 cm2 sample surface area.
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at
www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if
any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration,
forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
F055 Version5 SGS Korea Co.,Ltd.
204, GBMC, 155-1, Nongso-ri, Juchon-myeon, Gimhae-si, Gyeongnam, Korea 621-842
t +82 (0)55 3108 800 f +82 (0)55 3108 809 http://www.sgslab.co.kr , www.kr.sgs.com/greenlab
Page 3 of 3Issued Date: 2012. 10. 30Test Report No. F690101/LF-CTSAYAU12-05925
Testing Flow Chart for RoHS:Cd/Pb/Hg/Cr6+ Testing
Cd/Pb/Hg
Mechanic_Sample
Sample Measurement
Acid Digestion with
Microwave/Hotplate
Filtration
Residue
Total Digestion
ICP-AES/AAS
DATA
A Red Color Indicates
the Presence of Cr6+
Confirm
with UV-Vis
Cr
Sample Measurement
Adding Extraction Solution
Metallic Material
UV-Vis
DATA
Mechanic_Sample
6+
Filtration and pH Adjustment
Adding 1,5-Diphenylcarbazide
for Color Development
Heating to 90~95°C for Extraction
Nonmetallic Material
Adding 1,5-
Diphenylcarbazide
for Color Development
Mechanic_Sample
Sample Measurement
Spot Test / Boiling
Water Extraction
DATA
Cr 6+
The samples were dissolved totally by pre-conditioning method according to above flow chart for Cd,Pb,Hg.
Section Chief : Sharpless Park
*** End ***
NOTE: (1) N.D. = Not detected.(<MDL)
(2) mg/kg = ppm
(3) MDL = Method Detection Limit
(4) - = No regulation
(5) Negative = Undetectable / Positive = Detectable
(6) ** = Qualitative analysis (No Unit)
(7) * = Boiling-water-extraction:
Negative = Absence of CrVI coating
Positive = Presence of CrVI coating; the detected concentration in boiling-water-extraction
solution is equal or greater than 0.02 mg/kg with 50 cm2 sample surface area.
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at
www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if
any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration,
forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
F055 Version5 SGS Korea Co.,Ltd.
204, GBMC, 155-1, Nongso-ri, Juchon-myeon, Gimhae-si, Gyeongnam, Korea 621-842
t +82 (0)55 3108 800 f +82 (0)55 3108 809 http://www.sgslab.co.kr , www.kr.sgs.com/greenlab
Page 1 of 3Issued Date: 2012. 10. 30Test Report No. F690101/LF-CTSAYAU12-05913
POONGSAN CORPORATION
611 Daejung-ri,
Onsan-eup,
Ulju,
Ulsan
Korea
To:
The following merchandise was submitted and identified by the client as :
SGS File No. : AYAU12-05913
Product Name : C5210
Item No./Part No. : Phospher Bronze
2012. 10. 25
2012. 10. 30to2012. 10. 26
Received Date :
Test Period :
Test Results : For further details, please refer to following page(s)
Test Performed : SGS Korea tested the sample(s) selected by applicant with following results.
Conclusion : Based on the performed tests on submitted sample(s), the results comply with the RoHS
Directive 2002/95/EC and its subsequent amendments.
SGS Korea Co., Ltd. / Gimhae Laboratory
Thomas Hwang / Gimhae Lab. Mgr
Sharpless Park
Jonadan Lee
Taehee Kang
Jongsir Lim/Testing Person
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at
www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if
any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration,
forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
F055 Version5 SGS Korea Co.,Ltd.
204, GBMC, 155-1, Nongso-ri, Juchon-myeon, Gimhae-si, Gyeongnam, Korea 621-842
t +82 (0)55 3108 800 f +82 (0)55 3108 809 http://www.sgslab.co.kr , www.kr.sgs.com/greenlab
Page 2 of 3Issued Date: 2012. 10. 30Test Report No. F690101/LF-CTSAYAU12-05913
Sample No. : AYAU12-05913.001
C5210Sample Description :
Item No./Part No. : Phospher Bronze
N/AMaterials :
Heavy Metals
Test Items Unit Test Method MDL Results
1With reference to IEC 62321:2008, ICPCadmium (Cd) N.D.mg/kg
5With reference to IEC 62321:2008, ICPLead (Pb) 39mg/kg
2With reference to IEC 62321:2008, ICPMercury (Hg) N.D.mg/kg
-With reference to IEC 62321:2008Hexavalent Chromium (Cr VI) By boiling
water extraction*
Negative**
Picture of Sample as Received:
NOTE: (1) N.D. = Not detected.(<MDL)
(2) mg/kg = ppm
(3) MDL = Method Detection Limit
(4) - = No regulation
(5) Negative = Undetectable / Positive = Detectable
(6) ** = Qualitative analysis (No Unit)
(7) * = Boiling-water-extraction:
Negative = Absence of CrVI coating
Positive = Presence of CrVI coating; the detected concentration in boiling-water-extraction
solution is equal or greater than 0.02 mg/kg with 50 cm2 sample surface area.
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at
www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if
any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration,
forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
F055 Version5 SGS Korea Co.,Ltd.
204, GBMC, 155-1, Nongso-ri, Juchon-myeon, Gimhae-si, Gyeongnam, Korea 621-842
t +82 (0)55 3108 800 f +82 (0)55 3108 809 http://www.sgslab.co.kr , www.kr.sgs.com/greenlab
Page 3 of 3Issued Date: 2012. 10. 30Test Report No. F690101/LF-CTSAYAU12-05913
Testing Flow Chart for RoHS:Cd/Pb/Hg/Cr6+ Testing
Cd/Pb/Hg
Mechanic_Sample
Sample Measurement
Acid Digestion with
Microwave/Hotplate
Filtration
Residue
Total Digestion
ICP-AES/AAS
DATA
A Red Color Indicates
the Presence of Cr6+
Confirm
with UV-Vis
Cr
Sample Measurement
Adding Extraction Solution
Metallic Material
UV-Vis
DATA
Mechanic_Sample
6+
Filtration and pH Adjustment
Adding 1,5-Diphenylcarbazide
for Color Development
Heating to 90~95°C for Extraction
Nonmetallic Material
Adding 1,5-
Diphenylcarbazide
for Color Development
Mechanic_Sample
Sample Measurement
Spot Test / Boiling
Water Extraction
DATA
Cr 6+
The samples were dissolved totally by pre-conditioning method according to above flow chart for Cd,Pb,Hg.
Section Chief : Sharpless Park
*** End ***
NOTE: (1) N.D. = Not detected.(<MDL)
(2) mg/kg = ppm
(3) MDL = Method Detection Limit
(4) - = No regulation
(5) Negative = Undetectable / Positive = Detectable
(6) ** = Qualitative analysis (No Unit)
(7) * = Boiling-water-extraction:
Negative = Absence of CrVI coating
Positive = Presence of CrVI coating; the detected concentration in boiling-water-extraction
solution is equal or greater than 0.02 mg/kg with 50 cm2 sample surface area.
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at
www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if
any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration,
forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.
F055 Version5 SGS Korea Co.,Ltd.
204, GBMC, 155-1, Nongso-ri, Juchon-myeon, Gimhae-si, Gyeongnam, Korea 621-842
t +82 (0)55 3108 800 f +82 (0)55 3108 809 http://www.sgslab.co.kr , www.kr.sgs.com/greenlab
SAFETY DATA SHEET TECHNYL® 2413GW BRT Page: 1/7
Date : 2009/12/01 Version : A.01 Cancels and replaces version : 5.1
1. Product and company identification
a. Product Name: TECHNYL® 2413GW BRT
b. Usage and Restriction Recommended usage: Injection molding (Semi-processed products) Restriction: Industrial use only
c. Maker/Supplier/Distributor Maker: RHODIA POLYAMIDE Co., LTD Address: 3F Kangnam B/D, 1321-1, Seocho-Dong, Seocho-Gu, Seoul, KOREA Emergency Number: +82 52 231 0900 / +82 2 2108 4901 Responsible: PS team
2. Hazard identification a. Hazard classification
- Antimony trioxide Carcinogenicity: IARC Category 2B Target Organ Systemic Toxicity (1 time): Category 1 (Heart) Target organ systemic toxicity (1 time): Category 2 (Respiratory organs) Target organ systemic toxicity (Repeated):Category 1 (Respiratory organs)
b. Hazard statement: Pictogram: Not classified
Signal Word: Warning
Hazard Statement: H351 Suspected of causing cancer H372 Causes damage to organs through prolonged or repeated exposure H412 Harmful to aquatic life with long lasting effects
Precautionary statement - Prevention
P202 Do not handle until all safety precautions have been read and understood. P260 Do not breathe dust/fume/gas/mist/vapors/spray. P264 Wash hands thoroughly after handling P270 Do not eat, drink or smoke when using this product. P273 Avoid release to the environment. P280 Wear protective gloves/protective clothing/eye protection/face protection P284 Wear respiratory protection.
- Response P302+P352 IF ON SKIN: Wash with plenty of soap and water. P301+P330+P331 IF SWALLOWED: Rinse mouth. Do NOT induce vomiting P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present. P332+P313 IF skin irritation occurs: Get medical advice/ attention
SAFETY DATA SHEET TECHNYL® 2413GW BRT Page: 2/7
Date : 2009/12/01 Version : A.01 Cancels and replaces version : 5.1
- Storage
P410+P403 Protect from sunlight, Store in a well-ventilated place - Disposal
P501 Follow achievable methods for the disposal of a substance and package.
c. Further information: Although classified according to EC criteria (calculated by the conventional method), this product is exempt from labeling according to article 9.3 of Annex 6 of Directive 67/548/EEC, 28th ATP.
3. Composition / information on ingredients Chemical Substances CAS no EINECS no Content (%) Remark
Polyamide 66 32131-17-2 - > 42 Glass Fiber 65997-17-3 266-046-0 25
Brominated flame retardant Secret - < 20 Antimony trioxide 1309-64-4 215-175-0 < 10 Carcinogen Cat.2BOther additives Secret - < 3
Sum 100
4. First-aid measures a. Inhalation: Quickly move the person away from the contaminated area.
Make the affected person rest. If necessary seek medical advice.
b. Skin contact: Remove all contaminated clothing and footwear. Wash immediately and thoroughly for a prolonged period (at least 15 minutes).In case of inflammation (redness, irritation, ...) obtain medical attention.
c. Eye contact: Immediately rinse with plenty of running water for a prolonged period, (at least 15 minutes) whilst keeping the eyes wide open if irritation persists, consult a doctor.
d. Ingestion: NEVER attempt to induce vomiting. Do not give anything to drink. If necessary seek medical advice.
e. Major symptoms/effect of acute and Chronic toxicity: No data
f. Information for emergency measure and doctor: No data
5. Fire-fighting measures a. Extinguishing method:
Suitable: All extinguishable agents can be used - water, form, powders, carbon dioxide, sand, etc
SAFETY DATA SHEET TECHNYL® 2413GW BRT Page: 3/7
Date : 2009/12/01 Version : A.01 Cancels and replaces version : 5.1
Not suitable: None. If there is a fire close by, use suitable extinguishing agent
b. Specific hazards: Toxic vapors (halogen compounds) are released. Combustible product, melts on heating. Risk of fire spreading due to the flow of liquid which is already alight
c. Specific fire fighting methods: Cool the molten products.
d. Protection of fire-fighters: Self-contained breathing apparatus
6. Accidental release measures a. Personal precautions: Do not breathe fumes
b. Environmental precautions: This product does not present any particular risk for the environment.
c. Method for cleaning up - Recovery: Recover the product by vacuuming/shoveling or swelling. - Cleaning/Decontamination: Sweep
7. Handling and storage a. HANDLING Suitable: Earth the equipment used to transfer the product. Technical measure: Does not require any specific or particular measures. Safe handling advice: Handle and use in accordance with good occupational hygiene and safety
practice.
b. STORAGE Technical measure: Does not require any specific or particular technical measures. Storage condition: - Away from any flames.
- Protected from humidity and bad weather conditions. Incompatible products: Oxidizing materials
8. Exposure controls / personal protection a. Limit of exposure
Chemical substance ACGHI Antimony trioxide TWA - 0.5 mg/
b. Engineering measures: Extract to remove vapors at their source
c. Personal protection equipments Respiratory: Use dust protective mask Eye: Wear safety goggle. Hand: Wear chemically protective gloves Body: Wear dust protective wear
SAFETY DATA SHEET TECHNYL® 2413GW BRT Page: 4/7
Date : 2009/12/01 Version : A.01 Cancels and replaces version : 5.1
d. Work Practice Controls: Personal hygiene is an important work practice exposure control measure
and the following general measures should be taken when working with or handling this material:
Do not store, use, and/or consume foods, beverages, tobacco products, or cosmetics in areas where this material is stored.
Wash hands and face carefully before eating, drinking, using tobacco, applying cosmetics, or using the toilet
Wash exposed skin promptly to remove accidental splashes or contact with this material.
9. Physical and chemical properties a. Surface aspect Beige color pellet b. Smell N/A c. pH N/A d. Melting range 255~265 e. Boiling temp. N/A f. Flash point 350 (CC) g. Vaporized rate N/A h. Inflammability. Product will burn under fire conditions i. Ignition / Exposure range N/A j. Vapor pressure N/A k. Solubility Insoluble in water / organic solvent l. Vapor density N/A m. Specific gravity 1.54 n. n-Octanol/water distribution factor N/A o. Self ignition temp. > 450°C p. Degradation temp. > 350°C q. Viscosity 2.5 r. Molecular weight No evidence
10. STABILITY AND REACTIVITY a. Stability: Stable under normal conditions of use
b. Possibility of hazard reaction: Don't polymerize
c. Conditions to be avoided: Remove heat, fire, and heat sources
d. Materials/Chemicals to be avoided: Oxidizing material
e. Hazardous substances from decomposition (Thermal): Bromine, Hydrobromic acid, Oxides of antimony,
Carbon oxides (CO + CO2)
SAFETY DATA SHEET TECHNYL® 2413GW BRT Page: 5/7
Date : 2009/12/01 Version : A.01 Cancels and replaces version : 5.1
11. Toxicological information
a. Acute Eye Irritation: Not classified (by calculation according to the GHS method)
b. Acute Skin Irritation: Not classified (by calculation according to the GHS method)
c. Acute Respiratory Irritation: Not classified (by calculation according to the GHS method)
d. Acute Inhalation Toxicity: Not classified (by calculation according to the GHS method)
e. Acute Oral Toxicity: Not classified (by calculation according to the GHS method)
f. Chronic Toxicity: No test data found for product.
12. Ecological information a. Mobility Precipitation: Slightly soluble product, readily forms deposits. Expected behavior of the product: Ultimate destination of the product: SOIL and SEDIMENT.
b. Biodegradability Ultimate aerobic biodegradability: Not biodegradable (internal evaluation)
c. Bioaccumulation Octanol/Water partition coefficient: Not potentially bioaccumulable (internal evaluation)
d. Eco-toxicity Effect on the aquatic environment: Due to its physical state, this product does not have any known
adverse effect on the aquatic organism
13. Disposal considerations a. Residue from product
Destruction/Disposal: Recycle the material as far as possible. If it proves necessary to grind the product in order to recycle it, take all necessary precautions to prevent the formation and spread of dust.
Non recycled product: May be disposed of with non hazardous industrial waste. Incinerate at a licensed installation. Dispose of in accordance with relevant local regulations.
b. NOTE: The user's attention is drawn to the possible existence of local regulations regarding disposal
14. Transport information a. International regulations
Rail/road (RID/ADR): NOT restricted Sea (IMO/IMDG): NOT restricted
SAFETY DATA SHEET TECHNYL® 2413GW BRT Page: 6/7
Date : 2009/12/01 Version : A.01 Cancels and replaces version : 5.1
Air (ICAO-IATA): NOT restricted
b. NOTE: The above regulatory prescriptions are those valid on the date of publication of this sheet. Given the possible evolution of transport regulations for hazardous materials, it would be advisable to check their validity with your sales office.
15. Regulatory information a. Labeling: Korea regulations: Mandatory labeling (self-classification) of hazardous preparations:
NOT APPLICABLE
EC regulations: Mandatory labeling (self-classification) of hazardous preparations: NOT APPLICABLE
b. R Phases: R40: Limited evidence for carcinogen
c. S Phases: S2, S13, S36/37/39
d. Further data: Although classified according to EC criteria (calculated by conventional method), this product is exempt from labeling according to article 9.3 of Annex 6 of Directive 67/548/EEC, 28th ATP.
e. Further information: Packing confirms to Directive 94/62/EEC et to Decree 98-638.
f. NOTE: The regulatory information given above only indicators the principle regulations specifically applicable to the product described in the Safety Data Sheet. The user's attention is drawn to the possible existence of additional provisions which complete these regulations. Refer to all applicable national, international and local regulations or provisions.
16. Other information a. Uses
Prohibited use: For special application e.g. in medicine, surgery, or the food industry, obtain further information form the manufacturer.
Registration numbers: The polymers are not listed in the EINECS inventory. All the constituent of this preparation are registered in EINECS inventory.
b. Update: This sheet was updated (below paragraph was changed) to meet KOREA Government law and GHS guidelines.
2. Hazard identification 3. Composition / information on ingredients 4. First-aid measures 8. Exposure controls / personal protection 9. Physical and chemical properties 11. Toxicological information 12. Ecological information
SAFETY DATA SHEET TECHNYL® 2413GW BRT Page: 7/7
Date : 2009/12/01 Version : A.01 Cancels and replaces version : 5.1
13. Disposal considerations 15. Regulatory information
This safety data sheet should be used in conjunction with technical sheets. It does not replace them. The Information given is based on our knowledge of this product, at the time of publication. It is given in good faith. The attention of the user is drawn to the possible risks incurred by using the product for any other purpose other than that for which it was intended. This does not in any way excuse the user from knowing and applying all the regulations governing his activity. It is the sole responsibility of the user to take all precautions required in handling the products. The aim of the mandatory regulations mentioned is to help the user to fulfill his obligations regarding the use of hazardous products. This information is not exhaustive. This does not exonerate the user from ensuring that regal obligations, other than those mentioned, relating to the use and storage of the products, do not exist. This is solely his responsibility
Reg. No.
Issue Date
LG Twin Tower/ East Wing, 20,
Yoido-dong, Youngdungpo-gu
Seoul 150- 721, Korea
Tel : 82-2-3773-7743
Fax : 82-2-3773-7660 Page
1. CHEMICAL PRODUCT & COMPANY IDENTIFICATION ① Product Name : LUMID GN1001BF
② Product Type : PA Compound
③ Ext. Appearance : Pellet type plastic solid
④ Purpose / Use : May be used to produce molded or extruded particles or as a component of
other industrial products.
⑤ Manufacture : LG Chemical Ltd. Iksan Plant
599, Yongjei-dong, Iksan-city, Chunbuk-do, 570-350, Korea
Tel) 082-0653-830-4121, Fax) 082-0653-830-4036
⑥ Supplier : LG Chemical Ltd. / 20, Yoido-dong, Yongdungpo-gu, Seoul, 150-721, Korea
Tel) 082-02-3773-1114, Fax) 082-02-3773-7766, 7111
2. COMPOSITION / INFORMATION ON INGREDIENTSContant (%)
60 ~ 80
5 ~ 20
5 ~ 20
0 ~ 5
0
0
0
3. HAZARDS IDENTIFICATION NFPA RATINGS (SCALE 0-4) : HEALTH=1 FIRE=1 REACTIVITY=0
EC CLASSIFICATION (CALCULATED) : No classification assigned.
EMERGENCY OVERVIEWS :
Solid pellets with slight or no odor. Spilled pellets create slipping hazard.
Can burn in a fire creating dense toxic smoke. Molten plastic can cause severe thermal burns.
Fumes produced during melt processing may cause eye, skin and respiratory tract irritation.
Secondary operations, such as grinding, sanding or sawing, can producs dust which may present an
explosion or respiratory hazard.
POTENTIAL HEALTH EFFECTS :
EYE : Product may cause irritation or injury due to mechanical action.
SKIN : Pellets not likely to cause skin irritation.
INGESTION : Not acutely toxic.
INHALATION : Pellet inhalation unlikely due to physical form.
CHRONIC / CARCINOGENICITY :
NTP : Not Tested OSHA : Not Regulated IARC : Not Listed
Antimony and its compounds were reported as potential carcinogenic substance.
IARC had classified the glass fiber as noncarcinogenic material.
LG Chemical
LG Chemical
Version
0
0
Melamine Cyanuate - 37640-57-6
Others Additives -
0
0
2003.03.03
DGN1001BFM S D S
(Material Safety Data Sheet)
Chemical Name CAS NumberCommon Name
1 / 5LUMID GN1001BF
RevIsionDate
2009.11.04
4.0
Polyamide Nylon 6 25038-54-4
Polyamide Nylon 66 32131-17-2
PA Compound
0
0
Reg. No.
LG Chemical Version
Page
4. FIRST AID MEASURES
MEDICAL RESTRICTIONS :
EYE : Remove contract lenses at once. Immediately flush eyes well with copious
quantities of water or normal saline for at least 15-20 minutes. If irritation
persists, seek medical attention.
SKIN : seek medical attention if rash or burn occurs.
INGESTION : Not probable. If a large amount is swallowed, seek medical attention.
INHALATION : Not Likely to be inhaled due to physical form.
MELT PROCESSING :
For molten plastic skin contact, cool rapidly flush water and immediately seek medical attention.
Do not attempt removal of plastic without medical assistance. Do not use solvent for removal.
For processing fume inhalation irritation, leave contaminated area and breathe fresh air. If coughing,
difficult breathing or any other symptoms develop seek medical attention at once, even if symptoms
develop at a later time.
For skin contact with fume comdiesate, immediately eash thoroughly with soap and water. If irritation
develops seek medical attention.
5. FIRE FIGHTING MEASURES
FIRE FIGHTING :
Approved pressure demand breathing apparatus and pritective clothing should be used for all fires.
Water spray is the preferred extinguishing medium. This product will melt but will not be carried on
the surface for water.
EXTINGUISHING MEDIA :
Water spray and foam, Water is the best extinguishing medium. Carbon dioxide and dry chemical
are not generally recommended because their lack of cooling capacity may permit re-ignition.
HAZARDOUS COMBUSTION PRODUCTS :
Hazardous combustion products may include intense heat, dense black smoke, carbon monoxide,
carbon dioxide, oxides of phosphorus, hydrogen xyanide, hydrocarbon fragments, hydrogen
fluoride, carbonyl fluoride and fluorocarbon fragments.
FLASH POINT : Not Applicable
LOWER FLAMMABLE LIMIT : Not Established
UPPER FLAMMABLE LIMIT : Not Established
AUTOIGNITION : Not Established
FLAMMABILITY CONDITIONS : Requires a continuous flame source to ignite and sustain combustion.
EXPLOSION DATA : Not Established
IMPACT SENSITIVITY : Not sensitive to mechanical impact.
STATIC DISCHARGE : Not sensitive to static discharge. (See Section 7)
LG Chemical
DGN1001BF
4.0
2 / 5
PA Compound
LUMID GN1001BF
Reg. No.
LG Chemical Version
Page
6. ACCIDENTAL RELEASE MEASURES
GENERAL :
Sweep or gather up material and place in preper container for disposal or recovery. (See Section 13)
7. HANDLING AND STORAGE
HANDLING :
Follow recommendations on label and in processing guide. Prevent contact with skin and eyes.
Use good industrial hygiene proctices. Provide adequnte ventilation. Secondary operations such as
grinding, sanding or sawing may produce a dust explosion hazard. Use aggressive housekeeping
activities to prevent dust accumulation; employ bonding, grounding, venting and explosion relief
provisions in accordance with accepted engineering practices.
STORAGE :
Store in a dry place away from moisture, excessive heat and sources of ignition.
8. EXPOSURE CONTROLS / PERSONAL PROTECTION
ENGINEERING CONTROLS :
A continuous supply of fresh air to the workplace together with removal of processing fumes through
exhaust systems is recommended. Processing fume condensate may be a fire hazard and toxic;
remove periodically from exhaust hoods, duct work amd othwr suricaces using appropriate
personal protection. For piwders and residual dusts refer to Section 7.
PERSONAL PROTECTION :
EYE/FACE : Wear safety glasses with side shields or chemical goggles. In addition, use
full face shield when cleanning processing fume condensates from hoods,
ducts and other surfaces.
RESPIRATORY : When handling fumes are not adequstely controlled, use respirator approved
for protection from organic vapors and acid gases. When dust or powder
from secondary operations, such as grinding, sanding or sawing, are not
adequately controlled use respirator approved for protection from dust.
9. PHYSICAL AND CHEMICAL PROPERTIES
PHYSICAL STATE : Solid
COLOR AND APPEARANCE : Plastic pellet with slight odor
BOILING POINT : Not Applicable
MELTING POINT () : 260 ~ 270
VAPOR PRESSURE (mmHg) : Negligible
VAPOR DENSITY (Air=1) : Not Applicable
SPECIFIC GRAVITY : 1.15 ~ 1.25
WATER SOLUBILITY : Insoluble
LG Chemical
4.0
3 / 5LUMID GN1001BF
PA Compound DGN1001BF
Reg. No.
LG Chemical Version
Page
9. PHYSICAL AND CHEMICAL PROPERTIES (continued)
SOLVENT SOLUBILITY : Slightly soluble in strong polar slovent or chlorinated solvents
% VOLATITLES : Negligible
pH : Not Applicable
ODOR THRESHOLD : Not Established
EVAPORATION RATE : Negligible
COEFFICIENT WATER / OIL DISTRIBUTION : Not Established
COMMENT : This product does not exhibit a sharp melting point, but softens
gradually over a wide temperature range.
10. STABILITY AND REACTIVITY
STABILITY : Stable under recommended conditions of Section 7
REACTIVITY : Not reactive under recommended conditions of handling, storage, processing and use.
CONDITIONS TO AVOID :
Do not exceed melt temperature recommendations in product literature.
In order to avoid autolgnition/hazardous decomposition of hot thick meases of plastic, purgings should
be collected in small, flat shapes or thin strands to allow for rapid cooling and quenching in water.
Do not allow product to remain in barrel at elevated temperatures for extended periods of time ;
purge with a general purpose resin. (See Section 8 for respiratory protection advice)
HAZARDOUS DECOMPOSITION :
Major decomposition gases are oxidized hydrocarbons (probably carbon monoxide) and steam.
Minor components in decomposition gas may be phenolic compounds, hydrogen bromide, THF, etc.
11. TOXICOLOGICAL INFORMATION
Not Available
12. ECOLOGICAL INFORMATION
Not expected to present any significant ecological problems.
13. DISPOSAL CONSIDERATIONS
RCRA HAZARDOUS WASTE :
Products is not a RCRA hazardous waste.
WASTE DISPOSAL :
Recycling is encouraged. Landfill or incinerate in accourdance with federal, state and local
requirements. Collected processing fume condensates and incinerator ash should be tested to
determine waste classification.
LG Chemical
4 / 5
PA Compound
LUMID GN1001BF
DGN1001BF
4.0
Reg. No.
LG Chemical Version
Page
14. TRANSPORT INFORMATION
DOT HAZARD CLASS : Not Regulated
PROPER SHIPPING NAME : Not Regulated
IDENTIFICATION NUMBER : Not Listed
TDGA : Not Listed
15. REGULATORY INFORMATION
Listed below are chemical substances subject to supplier notification requirements.
U.S. REQULATIONS :
TSCA INVENTORY STATUS : This product complies with the Chemical Substance Inventory
requirements of the US EPA TSCA.
CERCLA SECTION 103 (40CFR302.4): Not Listed
SARA SECTION 313 (40CFR372.65): Not Listed
SARA HAZARD CATEGORIES, SARA SECTIONS 311/312 (40CFR370.21)
ACUTE : Not Listed
CHRONIC : Not Listed
FIRE : Not Listed
REACTIVE : Not Listed
SUDDEN RELEASE : Not Listed
STATE REQULATIONS :
California Proposition 65 : Not Listed
EUROPEAN REGULATIONS :
EC NUMBER : Not assigned
16. OTHER INFORMATION
The information submitted in this MSDS is based on our current knowledge and experience.
Because it is not possible to anticipate all conditions of use additional safety precautions may be
required, we make no warranty.
ABBREVIATIONS :
ACGIH : American Conference of Governmental Industrial Hygienist
DOT : Department of Transportation
EC : European Communities
EPA : Environmental Protection Agency
IARC : International Agency for Research on Cancer
NOISH : National Institute for Occupational Safety and Health
NTP : National Toxicology Program
OSHA : Occupational Safety and Health Administration
RTECS : Registry of Toxic Effects of Chemical Substances
CAS # : Chemical Abstracts Service Number
RCRA : Resource Conservation and Recovery Act
LG Chemical
PA Compound DGN1001BF
LUMID GN1001BF4.0
5 / 5
SAFETY DATA SHEET TECHNYL® 2413GW2 RED Page: 1/7
Date : 2009/12/01 Version : A.01 Cancels and replaces version : 1.1
1. Product and company identification
a. Product Name: TECHNYL® 2413GW2 RED
b. Usage and Restriction Recommended usage: Injection molding (Semi-processed products) Restriction: Industrial use only
c. Maker/Supplier/Distributor Maker: RHODIA POLYAMIDE Co., LTD Address: 3F Kangnam B/D, 1321-1, Seocho-Dong, Seocho-Gu, Seoul, KOREA Emergency Number: +82 52 231 0900 / +82 2 2108 4901 Responsible: PS team
2. Hazard identification a. Hazard classification
- Antimony trioxide Carcinogenicity: IARC Category 2B Target Organ Systemic Toxicity (1 time): Category 1 (Heart) Target organ systemic toxicity (1 time): Category 2 (Respiratory organs) Target organ systemic toxicity (Repeated):Category 1 (Respiratory organs)
b. Hazard statement: Pictogram: Not classified
Signal Word: Warning
Hazard Statement: H351 Suspected of causing cancer H372 Causes damage to organs through prolonged or repeated exposure H412 Harmful to aquatic life with long lasting effects
Precautionary statement - Prevention
P202 Do not handle until all safety precautions have been read and understood. P260 Do not breathe dust/fume/gas/mist/vapors/spray. P264 Wash hands thoroughly after handling P270 Do not eat, drink or smoke when using this product. P273 Avoid release to the environment. P280 Wear protective gloves/protective clothing/eye protection/face protection P284 Wear respiratory protection.
- Response P302+P352 IF ON SKIN: Wash with plenty of soap and water. P301+P330+P331 IF SWALLOWED: Rinse mouth. Do NOT induce vomiting P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present. P332+P313 IF skin irritation occurs: Get medical advice/ attention
SAFETY DATA SHEET TECHNYL® 2413GW2 RED Page: 2/7
Date : 2009/12/01 Version : A.01 Cancels and replaces version : 1.1
- Storage
P410+P403 Protect from sunlight, Store in a well-ventilated place - Disposal
P501 Follow achievable methods for the disposal of a substance and package.
c. Further information: Although classified according to EC criteria (calculated by the conventional method), this product is exempt from labeling according to article 9.3 of Annex 6 of Directive 67/548/EEC, 28th ATP.
.
3. Composition / information on ingredients Chemical Substances CAS no EINECS no Content (%) Remark
Polyamide 66 32131-17-2 - > 57 Glass Fiber 65997-17-3 266-046-0 10
Brominated flame retardant Secret - < 20 Antimony trioxide 1309-64-4 215-175-0 < 10 Carcinogen Cat.2BOther additives Secret - < 3
Sum 100
4. First-aid measures a. Inhalation: Quickly move the person away from the contaminated area.
Make the affected person rest. If necessary seek medical advice.
b. Skin contact: Remove all contaminated clothing and footwear. Wash immediately and thoroughly for a prolonged period (at least 15 minutes).In case of inflammation (redness, irritation, ...) obtain medical attention.
c. Eye contact: Immediately rinse with plenty of running water for a prolonged period, (at least 15 minutes) whilst keeping the eyes wide open if irritation persists, consult a doctor.
d. Ingestion: NEVER attempt to induce vomiting. Do not give anything to drink. If necessary seek medical advice.
e. Major symptoms/effect of acute and Chronic toxicity: No data
f. Information for emergency measure and doctor: No data
5. Fire-fighting measures a. Extinguishing method:
Suitable: All extinguishable agents can be used - water, form, powders, carbon dioxide, sand, etc
SAFETY DATA SHEET TECHNYL® 2413GW2 RED Page: 3/7
Date : 2009/12/01 Version : A.01 Cancels and replaces version : 1.1
Not suitable: None. If there is a fire close by, use suitable extinguishing agent
b. Specific hazards: Toxic vapors (halogen compounds) are released. Combustible product, melts on heating. Risk of fire spreading due to the flow of liquid which is already alight
c. Specific fire fighting methods: Cool the molten products.
d. Protection of fire-fighters: Self-contained breathing apparatus
6. Accidental release measures a. Personal precautions: Do not breathe fumes
b. Environmental precautions: This product does not present any particular risk for the environment.
c. Method for cleaning up - Recovery: Recover the product by vacuuming/shoveling or swelling. - Cleaning/Decontamination: Sweep
7. Handling and storage a. HANDLING Suitable: Earth the equipment used to transfer the product. Technical measure: Does not require any specific or particular measures. Safe handling advice: Handle and use in accordance with good occupational hygiene and safety
practice.
b. STORAGE Technical measure: Does not require any specific or particular technical measures. Storage condition: - Away from any flames.
- Protected from humidity and bad weather conditions. Incompatible products: Oxidizing materials
8. Exposure controls / personal protection a. Limit of exposure
Chemical substance ACGHI Antimony trioxide TWA - 0.5 mg/
b. Engineering measures: Extract to remove vapors at their source
c. Personal protection equipments Respiratory: Use dust protective mask Eye: Wear safety goggle. Hand: Wear chemically protective gloves Body: Wear dust protective wear
SAFETY DATA SHEET TECHNYL® 2413GW2 RED Page: 4/7
Date : 2009/12/01 Version : A.01 Cancels and replaces version : 1.1
d. Work Practice Controls: Personal hygiene is an important work practice exposure control measure
and the following general measures should be taken when working with or handling this material:
Do not store, use, and/or consume foods, beverages, tobacco products, or cosmetics in areas where this material is stored.
Wash hands and face carefully before eating, drinking, using tobacco, applying cosmetics, or using the toilet
Wash exposed skin promptly to remove accidental splashes or contact with this material.
9. Physical and chemical properties a. Surface aspect RED color pellet b. Smell N/A c. pH N/A d. Melting range 255~265 e. Boiling temp. N/A f. Flash point 350 (CC) g. Vaporized rate N/A h. Inflammability. Product will burn under fire conditions i. Ignition / Exposure range N/A j. Vapor pressure N/A k. Solubility Insoluble in water / organic solvent l. Vapor density N/A m. Specific gravity 1.43 n. n-Octanol/water distribution factor N/A o. Self ignition temp. > 450°C p. Degradation temp. > 350°C q. Viscosity 2.5 r. Molecular weight No evidence
10. STABILITY AND REACTIVITY a. Stability: Stable under normal conditions of use
b. Possibility of hazard reaction: Don't polymerize
c. Conditions to be avoided: Remove heat, fire, and heat sources
d. Materials/Chemicals to be avoided: Oxidizing material
e. Hazardous substances from decomposition (Thermal): Bromine, Hydrobromic acid, Oxides of antimony,
Carbon oxides (CO + CO2)
SAFETY DATA SHEET TECHNYL® 2413GW2 RED Page: 5/7
Date : 2009/12/01 Version : A.01 Cancels and replaces version : 1.1
11. Toxicological information
a. Acute Eye Irritation: Not classified (by calculation according to the GHS method)
b. Acute Skin Irritation: Not classified (by calculation according to the GHS method)
c. Acute Respiratory Irritation: Not classified (by calculation according to the GHS method)
d. Acute Inhalation Toxicity: Not classified (by calculation according to the GHS method)
e. Acute Oral Toxicity: Not classified (by calculation according to the GHS method)
f. Chronic Toxicity: No test data found for product.
12. Ecological information a. Mobility Precipitation: Slightly soluble product, readily forms deposits. Expected behavior of the product: Ultimate destination of the product: SOIL and SEDIMENT.
b. Biodegradability Ultimate aerobic biodegradability: Not biodegradable (internal evaluation)
c. Bioaccumulation Octanol/Water partition coefficient: Not potentially bioaccumulable (internal evaluation)
d. Eco-toxicity Effect on the aquatic environment: Due to its physical state, this product does not have any known
adverse effect on the aquatic organism
13. Disposal considerations a. Residue from product
Destruction/Disposal: Recycle the material as far as possible. If it proves necessary to grind the product in order to recycle it, take all necessary precautions to prevent the formation and spread of dust.
Non recycled product: May be disposed of with non hazardous industrial waste. Incinerate at a licensed installation. Dispose of in accordance with relevant local regulations.
b. NOTE: The user's attention is drawn to the possible existence of local regulations regarding disposal
14. Transport information a. International regulations
Rail/road (RID/ADR): NOT restricted Sea (IMO/IMDG): NOT restricted
SAFETY DATA SHEET TECHNYL® 2413GW2 RED Page: 6/7
Date : 2009/12/01 Version : A.01 Cancels and replaces version : 1.1
Air (ICAO-IATA): NOT restricted
b. NOTE: The above regulatory prescriptions are those valid on the date of publication of this sheet. Given the possible evolution of transport regulations for hazardous materials, it would be advisable to check their validity with your sales office.
15. Regulatory information a. Labeling: Korea regulations: Mandatory labeling (self-classification) of hazardous preparations:
NOT APPLICABLE
EC regulations: Mandatory labeling (self-classification) of hazardous preparations: NOT APPLICABLE
b. R Phases: R40: Limited evidence for carcinogen
c. S Phases: S2, S13, S36/37/39
d. Further data: Although classified according to EC criteria (calculated by conventional method), this product is exempt from labeling according to article 9.3 of Annex 6 of Directive 67/548/EEC, 28th ATP.
e. Further information: Packing confirms to Directive 94/62/EEC et to Decree 98-638.
f. NOTE: The regulatory information given above only indicators the principle regulations specifically applicable to the product described in the Safety Data Sheet. The user's attention is drawn to the possible existence of additional provisions which complete these regulations. Refer to all applicable national, international and local regulations or provisions.
16. Other information a. Uses
Prohibited use: For special application e.g. in medicine, surgery, or the food industry, obtain further information form the manufacturer.
Registration numbers: The polymers are not listed in the EINECS inventory. All the constituent of this preparation are registered in EINECS inventory.
b. Update: This sheet was updated (below paragraph was changed) to meet KOREA Government law and GHS guidelines.
2. Hazard identification 3. Composition / information on ingredients 4. First-aid measures 8. Exposure controls / personal protection 9. Physical and chemical properties 11. Toxicological information 12. Ecological information
SAFETY DATA SHEET TECHNYL® 2413GW2 RED Page: 7/7
Date : 2009/12/01 Version : A.01 Cancels and replaces version : 1.1
13. Disposal considerations 15. Regulatory information
This safety data sheet should be used in conjunction with technical sheets. It does not replace them. The Information given is based on our knowledge of this product, at the time of publication. It is given in good faith. The attention of the user is drawn to the possible risks incurred by using the product for any other purpose other than that for which it was intended. This does not in any way excuse the user from knowing and applying all the regulations governing his activity. It is the sole responsibility of the user to take all precautions required in handling the products. The aim of the mandatory regulations mentioned is to help the user to fulfill his obligations regarding the use of hazardous products. This information is not exhaustive. This does not exonerate the user from ensuring that regal obligations, other than those mentioned, relating to the use and storage of the products, do not exist. This is solely his responsibility
Date IssuedDate IssuedDate IssuedDate Issued Apr.23.2009Apr.23.2009Apr.23.2009Apr.23.2009
Revision NoRevision NoRevision NoRevision No 1111
Material Safety Data SheetMaterial Safety Data SheetMaterial Safety Data SheetMaterial Safety Data Sheet
Copper & Brass Sales -- Brass Strip, Plate, Wire (C2600, C2680, C2700, C2800, C2801)
Material Safety Data Sheet
Part Number/Trade Name : Brass Strip, Plate, Wire
1. Product and Company Identification1. Product and Company Identification1. Product and Company Identification1. Product and Company Identification
Item Name: Brass Strip, Plate, Wire (C2600, C2680, C2700, C2800, C2801)①
Company's Name: POONGSAN CORPORATION②
Company's Address : 611, Daejung-Ri, Onsan-Up, Ulju-Kun, Ulsan, 689-890, SOUTH KOREA③
Phone Number : 81-52-231-9302④
Fax Number : 81-52-231-9400⑤
2. Composition2. Composition2. Composition2. Composition
Element Elementary Symbol CAS Number Content
Copper Cu 7440-50-8 61.0%~70.5%
Zinc Zn 7440-66-6 39.0%~29.5%
3. Hazard Identification3. Hazard Identification3. Hazard Identification3. Hazard Identification
Route Of Entry①
- Inhalation: YES
- Skin: YES
- Ingestion: YES
Health Hazard Acute and Chronic②
- Copper Inhalation : Fumes may cause metal fume fever.
- Skin: Dermatitis, Keratinzation of the hands & the soles of the feet.
- Copper dust & fume cause irritation of the upper respiratory tract.
Carcinogenicity : None③
4. First Aid Measures4. First Aid Measures4. First Aid Measures4. First Aid Measures
Inhalation : Breathing difficulty caused by inhalation of particulate requires immediate removal to①
fresh air. If breathing has stopped, perform artificial respiration and obtain medical help
Ingestion : Induce vomiting immediately as directed by medical personnel. Never give anything by②
mouth to an unconscious person.
Skin : Thoroughly wash skin cuts or wounds to remove all particulate debris from the wound. Seek③
medical attention for wounds that cannot be thoroughly cleansed. Treat skin cuts and wounds
with standard first aid practices such as cleansing, disinfecting and covering to prevent wound
infection and contamination before continuing work. Obtain medical help for persistent irritation.
Material accidentally implanted or lodged under the skin must be removed.
Eyes : Immediately flush eyes with plenty of water for at least 15 minutes, lifting lower and upper④
eyelids occasionally. Get medical attention immediately.
5. Fire Fighting Measures5. Fire Fighting Measures5. Fire Fighting Measures5. Fire Fighting Measures
Unusual Fire And Explosion Hazards : Solid massive form isn't combustible. Molten metal may react①
violently water.
Extinguishing Media : Use special mixtures of dry chemical/sand.②
Special Fire Fighting Procedures : Pressure-demand self-contained breathing apparatus must be③
worn by firefighters or any other persons potentially exposed to the metal fumes or dust release
during or after a fire.
6. Accidental Release Measures6. Accidental Release Measures6. Accidental Release Measures6. Accidental Release Measures
Steps If Material Released or Spill : Remove by vacuuming/wet sweeping to Prevent heavy①
concentration of airborne dust. If liquids containing solubilized metal are spilled evacuate area.
Absorb by mens of vermiculite, dry sand/similar material
7. Handing and Storage7. Handing and Storage7. Handing and Storage7. Handing and Storage
Handling : Particulate may enter the body through cuts, abrasions or other wounds on the surface①
of the skin. Wear gloves when handing parts with loose surface particulate or sharp edges.
Storage : Store in a dry area.②
8. Exposure Controls, Personal Protection8. Exposure Controls, Personal Protection8. Exposure Controls, Personal Protection8. Exposure Controls, Personal Protection
Allowing concentration①
- TWA : 10 / (Total Dust, OSHA Standard)
Respiratory Protection : If exposure above the PEL/TLV, wear NIOSH/MSHA approved respirator.②
Ventilation : Local exhaust ventilation.③
Personal Protection④
- Protective Gloves : Required
- Eye Protection : Safety glasses W/side shields
- Other Protective Equipment : Face shields, specially tinted glass.
9. Physical And Chemical Properties9. Physical And Chemical Properties9. Physical And Chemical Properties9. Physical And Chemical Properties
Physical State : Solid①
pH : Not Applicable②
Melting Point : 900③
Density : 8.50④
Odor : None⑤
Evaporation Rate : Not Applicable⑥
Freezing Point : Not Applicable⑦
Radioactivity : Not Applicable⑧
Solubility : None⑨
Vapor Pressure : Not Applicable⑩
10. Stability And Reactivity10. Stability And Reactivity10. Stability And Reactivity10. Stability And Reactivity
General Reactivity : The Material is stable①
Incompatibility : Reacts with some acids and caustic solutions to produce hydrogen gas.②
Hydrogen gas can be an explosion hazard
Hazardous Decomposition Products : None under normal conditions of use③
Hazardous Polymerization : Will not occur④
11. Toxicological information11. Toxicological information11. Toxicological information11. Toxicological information
No human data are available for this product①
12. Ecological Information12. Ecological Information12. Ecological Information12. Ecological Information
This material is recyclable①
13. Disposal Considerations13. Disposal Considerations13. Disposal Considerations13. Disposal Considerations
Waste Disposal Method : Dispose of low/federal, State & local regulations①
Byproduct Recycling : When recycled(used in a process to recover metals), this material is not②
classified as hazardous waste under federal law. Seal particulate or particulate containing materials
inside two plastic bags, place in a DOT approved container, and label appropriately.
Solid Waste Management : When spent products are declared solid wastes (no longer recyclable),③
they must be labeled, managed and disposed of, in accordance with federal, state and local
requirements.
14. Transport Information14. Transport Information14. Transport Information14. Transport Information
None reported①
15. Regulatory Information15. Regulatory Information15. Regulatory Information15. Regulatory Information
Occupational Safety and Health Administration①
Air contaminants, 29 CFR 1910.1000
Hazard Communication Standard, 29 CFR 1910.1200
16. Other Information16. Other Information16. Other Information16. Other Information
The information above is believed to be accurate and represents the best information currently
available to us. However, we make no warranty of merchantability or any other warranty, express or
implied, with respect to such information, and we assume no liability resulting from its use. Users
should make their own investigations to determine the suitability of the Information for their particular
purposes. If you require more information, please contact us at the location listed on the page of this
report.
Date IssuedDate IssuedDate IssuedDate Issued Jun.4.2010Jun.4.2010Jun.4.2010Jun.4.2010
Revision NoRevision NoRevision NoRevision No 2222
Material Safety Data SheetMaterial Safety Data SheetMaterial Safety Data SheetMaterial Safety Data Sheet
Copper & Brass Sales -- Phosphor Bronze Strip (C5102, C5111, C5191, C5212, C5210, C5240)
Material Safety Data Sheet
Part Number/Trade Name : Phosphor Bronze Strip
1. Product and Company Identification1. Product and Company Identification1. Product and Company Identification1. Product and Company Identification
Item Name : Phosphor Bronze Strip (C5102, C5111, C5191, C5212, C5210, C5240)①
Company's Name : POONGSAN CORPORATION②
Company's Address : 611, Daejung-Ri, Onsan-Up, Ulju-Kun, Ulsan, 689-890, SOUTH KOREA③
Phone Number : 81-52-231-9302④
Fax Number : 81-52-231-9400⑤
2. Composition2. Composition2. Composition2. Composition
Element Elementary Symbol CAS Number Content
Copper Cu 7440-50-8 89.3%~96.5%
Tin Sn 7440-31-5 3.5%~10.5%
Phosphorus P 7723-14-0 0.03%~0.2%
3. Hazard Identification3. Hazard Identification3. Hazard Identification3. Hazard Identification
Route Of Entry①
- Inhalation: YES
- Skin: YES
- Ingestion: YES
Health Hazard Acute and Chronic②
- Copper Inhalation : Fumes may cause metal fume fever.
- Skin: Dermatitis, Keratinzation of the hands & the soles of the feet.
- Copper dust & fume cause irritation of the upper respiratory tract.
Carcinogenicity : None③
4. First Aid Measures4. First Aid Measures4. First Aid Measures4. First Aid Measures
Inhalation : Breathing difficulty caused by inhalation of particulate requires immediate removal to①
fresh air. If breathing has stopped, perform artificial respiration and obtain medical help
Ingestion : Induce vomiting immediately as directed by medical personnel. Never give anything by②
mouth to an unconscious person.
Skin : Thoroughly wash skin cuts or wounds to remove all particulate debris from the wound. Seek③
medical attention for wounds that cannot be thoroughly cleansed. Treat skin cuts and wounds
with standard first aid practices such as cleansing, disinfecting and covering to prevent wound
infection and contamination before continuing work. Obtain medical help for persistent irritation.
Material accidentally implanted or lodged under the skin must be removed.
Eyes : Immediately flush eyes with plenty of water for at least 15 minutes, lifting lower and upper④
eyelids occasionally. Get medical attention immediately.
5. Fire Fighting Measures5. Fire Fighting Measures5. Fire Fighting Measures5. Fire Fighting Measures
Unusual Fire And Explosion Hazards : Solid massive form isn't combustible. Molten metal may react①
violently water.
Extinguishing Media : Use special mixtures of dry chemical/sand.②
Special Fire Fighting Procedures : Pressure-demand self-contained breathing apparatus must be③
worn by firefighters or any other persons potentially exposed to the metal fumes or dust release
during or after a fire.
6. Accidental Release Measures6. Accidental Release Measures6. Accidental Release Measures6. Accidental Release Measures
Steps If Material Released or Spill : Remove by vacuuming/wet sweeping to Prevent heavy①
concentration of airborne dust. If liquids containing solubilized metal are spilled evacuate area.
Absorb by mens of vermiculite, dry sand/similar material
7. Handing and Storage7. Handing and Storage7. Handing and Storage7. Handing and Storage
Handling : Particulate may enter the body through cuts, abrasions or other wounds on the surface①
of the skin. Wear gloves when handing parts with loose surface particulate or sharp edges.
Storage : Store in a dry area.②
8. Exposure Controls, Personal Protection8. Exposure Controls, Personal Protection8. Exposure Controls, Personal Protection8. Exposure Controls, Personal Protection
Allowing concentration①
- TWA : 10 / (Total Dust, OSHA Standard)
Respiratory Protection : If exposure above the PEL/TLV, wear NIOSH/MSHA approved respirator.②
Ventilation : Local exhaust ventilation.③
Personal Protection④
- Protective Gloves : Required
- Eye Protection : Safety glasses W/side shields
- Other Protective Equipment : Face shields, specially tinted glass.
9. Physical And Chemical Properties9. Physical And Chemical Properties9. Physical And Chemical Properties9. Physical And Chemical Properties
Physical State : Solid①
pH : Not Applicable②
Melting Point : 1,020③
Density : 8.80④
Odor : None⑤
Evaporation Rate : Not Applicable⑥
Freezing Point : Not Applicable⑦
Radioactivity : Not Applicable⑧
Solubility : None⑨
Vapor Pressure : Not Applicable⑩
10. Stability And Reactivity10. Stability And Reactivity10. Stability And Reactivity10. Stability And Reactivity
General Reactivity : The Material is stable①
Incompatibility : Reacts with some acids and caustic solutions to produce hydrogen gas.②
Hydrogen gas can be an explosion hazard
Hazardous Decomposition Products : None under normal conditions of use③
Hazardous Polymerization : Will not occur④
11. Toxicological information11. Toxicological information11. Toxicological information11. Toxicological information
No human data are available for this product①
12. Ecological Information12. Ecological Information12. Ecological Information12. Ecological Information
This material is recyclable①
13. Disposal Considerations13. Disposal Considerations13. Disposal Considerations13. Disposal Considerations
Waste Disposal Method : Dispose of low/federal, State & local regulations①
Byproduct Recycling : When recycled(used in a process to recover metals), this material is not②
classified as hazardous waste under federal law. Seal particulate or particulate containing materials
inside two plastic bags, place in a DOT approved container, and label appropriately.
Solid Waste Management : When spent products are declared solid wastes (no longer recyclable),③
they must be labeled, managed and disposed of, in accordance with federal, state and local
requirements.
14. Transport Information14. Transport Information14. Transport Information14. Transport Information
None reported①
15. Regulatory Information15. Regulatory Information15. Regulatory Information15. Regulatory Information
Occupational Safety and Health Administration①
Air contaminants, 29 CFR 1910.1000
Hazard Communication Standard, 29 CFR 1910.1200
16. Other Information16. Other Information16. Other Information16. Other Information
The information above is believed to be accurate and represents the best information currently
available to us. However, we make no warranty of merchantability or any other warranty, express or
implied, with respect to such information, and we assume no liability resulting from its use. Users
should make their own investigations to determine the suitability of the Information for their particular
purposes. If you require more information, please contact us at the location listed on the page of this
report.
정일자ESTA. Date 2004. 03. 17 H O U S I N G Q C 공 정 도
PRODUCT&PROCESS CHART (HOUSING)= = = = = = = = = = = = = = = = = = = = = = = = = = = = =
작성일자 : 2004. 03. 17 작성부서 : 품질관리실 작 성 자 : 서 홍 엽
D A T E : 2004. 03. 17 D E P T .: QUALITY CONTROL WRITTEN BY : MR.H Y SEO
결재
APR`D
작 성WRIT`N
검 토CHK`D
승 인APR`D
개정일자REV. Date
시행일자EFFECT.Date 2004. 03. 17
문서번호FILE. NO Q - M - 001
NO
공정명
PROCESS
NAME
흐름도 사용설비
및 장비
EQUIPMENT
공 정 관 리 (MGT OF PROCESS) 검 사 관 리 (MGT OF INSPECTION)관련표준
STANDARDIZE부공정SUB PROCESS
주공정MAIN PROCESS
항 목I T E M
관리기준MGT.RULE
검사항목ITEM
검사방식METHOD
판정기준JUDGEMENT
01
02
03
04
05
06
07
원자재 입고
INCOMING
MATERIAL
수입 검사
INCOMING
INSPECTION
INJECTION
공정 및
최종검사
Process&
Final Test
포 장
PACKAGE
보 관
STORAGE
출하 검사
OUTGOING
TEST
사 출 기
EJECTOR
저울,SEALING기
Digital Scale
Packer
V/C,공구현미경
V/C,TOOL M/S
형체력(Shape)
DRY HOPPER온도(DRY HOPPER Temp)
OIL 온도(OIL Temp)
OIL량(Quantity of Oil)
AIR 공급량(Air Pressure)
수량(Quantity)
포장상태(State of Package)
작업표준
STD OF WORK
포장관리
규칙
Package
Regulation
겉모양(Shape)
물성(Certificate
of Propertied)
겉모양(Shape)
겉모양(Shape)
치수(Dimension)
형합성(Matching)
체크검사
CHECK
체크검사
CHECK
체크검사(CHECK)
계수조정형샘플링
MIL-STD-105D
수입검사 규격
STD OF INCOMING
INSPECTION
공정 및 최종
검사 규격
STD OF PROCESS
& FINAL TEST
출하검사 규격
STD OF OUTGOING
TEST
YSI-101-003
YSI-091-004
YSI-102-001
YSP-152
YSI-102-100
S.H.Y
03/17
B.J.S
03/17
S.S.S
03/17
제정일자ESTA. Date 2004. 03. 17 W A F E R Q C 공 정 도
PRODUCT&PROCESS CHART (WAFER)= = = = = = = = = = = = = = = = = = = = = = = = = = = = =
작성일자 : 2004. 03. 17 작성부서 : 품질관리실 작 성 자 : 서 홍 엽
D A T E : 2004. 03. 17 D E P T .: QUALITY CONTROL WRITTEN BY : MR.H Y SEO
결재
APR`D
작 성WRIT`N
검 토CHK`D
승 인APR`D
개정일자REV. Date
시행일자EFFECT.Date 2004. 03. 17
문서번호FILE. NO Q - M - 002
NO
공정명
PROCESS
NAME
흐름도 사용설비
및 장비
EQUIPMENT
공 정 관 리 (MGT OF PROCESS) 검 사 관 리 (MGT OF INSPECTION)관련표준
STANDARDIZE부공정SUB PROCESS
주공정MAIN PROCESS
항 목I T E M
관리기준MGT.RULE
검사항목ITEM
검사방식METHOD
판정기준JUDGEMENT
01
02
03
04
05
06
원자재 입고
INCOMING
MATERIAL
수입 검사
INCOMING
INSPECTION
INJECTION
공정 및
최종검사
Process&
Final Test
포 장
PACKAGE
운 반
STORAGE
사 출 기
EJECTOR
저울,SEALING기
Digital Scale
Packer
운반차
Carrier
형체력(Shape)
DRY HOPPER온도(DRY HOPPER Temp)
OIL 온도(OIL Temp)
OIL량(Quantity of Oil)
AIR 공급량(Air Pressure)
수량(Quantity)
포장상태(State of Package)
작업표준
STD OF WORK
포장관리규칙
Package
Regulation
겉모양(Shape)
물성(Certificate
of Propertied)
겉모양(Shape)
체크검사
CHECK
체크검사
CHECK
수입검사 규격
STD OF INCOMING
INSPECTION
공정 및 최종
검사 규격
STD OF PROCESS
& FINAL TEST
YSI-101-003
YSI-091-004
YSI-102-001
YSP-152
S.H.Y
03/17
B.J.S
03/17
S.S.S
03/17
제정일자ESTA. Date 2004. 03. 17 P I N Q C 공 정 도
PRODUCT&PROCESS CHART (PIN)= = = = = = = = = = = = = = = = = = = = = = = = = = = = =
작성일자 : 2004. 03. 17 작성부서 : 품질관리실 작 성 자 : 서 홍 엽
D A T E : 2004. 03. 17 D E P T .: QUALITY CONTROL WRITTEN BY : MR.H Y SEO
결재
APR`D
작 성WRIT`N
검 토CHK`D
승 인APR`D
개정일자REV. Date
시행일자EFFECT.Date 2004. 03. 17
문서번호FILE. NO Q - P - 002
NO
공정명
PROCESS
NAME
흐름도 사용설비
및 장비
EQUIPMENT
공 정 관 리 (MGT OF PROCESS) 검 사 관 리 (MGT OF INSPECTION)관련표준
STANDARDIZE부공정SUB PROCESS
주공정MAIN PROCESS
항 목I T E M
관리기준MGT.RULE
검사항목ITEM
검사방식METHOD
판정기준JUDGEMENT
01
02
03
04
05
06
07
원자재 입고
INCOMING
MATERIAL
수입 검사
INCOMING
INSPECTION
CUTTING
공정 및
최종검사
Process&
Final Test
포 장
PACKAGE
보 관
STORAGE
외주도금
PLATING VENDOR
CUTTING
MACHINE
V/C
저 울
Digital Scale
원재료 풀림상태(MATERIAL WINDING)
CAM고정상태(STATE OF CAM)
PUNCH고정상태(STATE OF PUNCH)
FEEDING 동작상태(FEEDING)
CHIP가루발생(CHIP OCCURRENCE)
BEARING 및 GEAR 동작상태
(BEARING, & GEAR)
수량(Quantity)
포장상태(State of Package)
작업표준
STD OF WORK
포장관리규칙
Package
Regulation
겉모양(Shape)
치수(Dimension)
물성(Certificate
of Propertied)
겉모양(Shape)
체크검사
CHECK
체크검사
CHECK
수입검사 규격
STD OF INCOMING
INSPECTION
공정 및 최종
검사 규격
STD OF PROCESS
& FINAL TEST
YSI-102-004
YSI-091-007
YSI-102-004
YSP-152
S.H.Y
03/17
B.J.S
03/17
S.S.S
03/17
제정일자ESTA. Date 2004. 03. 17 T E R M I N A L Q C 공 정 도
PRODUCT&PROCESS CHART (TERMINAL)= = = = = = = = = = = = = = = = = = = = = = = = = = = = =
작성일자 : 2004. 03. 17 작성부서 : 품질관리실 작 성 자 : 서 홍 엽
D A T E : 2004. 03. 17 D E P T .: QUALITY CONTROL WRITTEN BY : MR.H Y SEO
결재
APR`D
작 성WRIT`N
검 토CHK`D
승 인APR`D
개정일자REV. Date
시행일자EFFECT.Date 2004. 03. 17
문서번호FILE. NO Q - P - 001
NO
공정명
PROCESS
NAME
흐름도 사용설비
및 장비
EQUIPMENT
공 정 관 리 (MGT OF PROCESS) 검 사 관 리 (MGT OF INSPECTION)관련표준
STANDARDIZE부공정SUB PROCESS
주공정MAIN PROCESS
항 목I T E M
관리기준MGT.RULE
검사항목ITEM
검사방식METHOD
판정기준JUDGEMENT
01
02
03
04
05
06
07
원자재 입고
INCOMING
MATERIAL
수입 검사
INCOMING
INSPECTION
PRESS
공정 및
최종검사
Process&
Final Test
포 장
PACKAGE
보 관
STORAGE
출하 검사
OUTGOING
TEST
PRESS
저울,SEALING기
Digital Scale
Packer
V/C,공구현미경
V/C,TOOL M/S
유압 OIL량(Oil Pressure)
AIR 공급량(Air Pressure)
원재료 및 간지 풀림(Winding)
수량 CHECK SENSOR(Counter Sensor)
금형 이상 유무(State of press Tool)
타발유 도포(Oil Injection)
OIL 냉각장치(Oil Cooler)
수량(Quantity)
포장상태(State of Package)
작업표준
STD OF WORK
포장관리규칙
Package
Regulation
겉모양(Shape)
치수(Dimension)
도금두께
(Coating Thickness)
물성(Certificates
of Propertied)
납땜성
(Solderability)
겉모양(Shape)
치수(Dimension)
형합성(Matching)
겉모양(Shape)
치수(Dimension)
형합성(Matching)
체크검사
CHECK
체크검사
CHECK
체크검사(CHECK)
계수조정형샘플링
MIL-STD-105D
수입검사 규격
STD OF INCOMING
INSPECTION
공정 및 최종
검사 규격
STD OF PROCESS
& FINAL TEST
출하검사 규격
STD OF OUTGOING
TEST
YSI-101-004
YSI-091-005
YSI-102-002
YSP-152
YSI-102-100
S.H.Y
03/17
B.J.S
03/17
S.S.S
03/17
제정일자ESTA. Date 2004. 03. 17 W A F E R A S S ` Y Q C 공 정 도
PRODUCT&PROCESS CHART (WAFER ASS`Y)= = = = = = = = = = = = = = = = = = = = = = = = = = = = =
작성일자 : 2004. 03. 17 작성부서 : 품질관리실 작 성 자 : 서 홍 엽
D A T E : 2004. 03. 17 D E P T .: QUALITY CONTROL WRITTEN BY : MR.H Y SEO
결재
APR`D
작 성WRIT`N
검 토CHK`D
승 인APR`D
개정일자REV. Date
시행일자EFFECT.Date 2004. 03. 17
문서번호FILE. NO Q - A - 001
NO
공정명
PROCESS
NAME
흐름도 사용설비
및 장비
EQUIPMENT
공 정 관 리 (MGT OF PROCESS) 검 사 관 리 (MGT OF INSPECTION)관련표준
STANDARDIZE부공정SUB PROCESS
주공정MAIN PROCESS
항 목I T E M
관리기준MGT.RULE
검사항목ITEM
검사방식METHOD
판정기준JUDGEMENT
01
02
03
04
05
06
07
도금핀 입고INCOMINGPlated Pin
수입 검사INCOMINGInspection
조 립ASS'Y
공정 및최종검사PROCESS &FINAL TEST
포 장PACKAGE
보 관STORAGE
출하검사OUTGOINGTEST
납땜조(Solder Port)도금두께측정기(Coating ThicknessGauge), V/C조립기(ASS'Y M/C)
공구현미경,V/C(Tool M/C),V/CPush Pull Gage통전기(Short Checker)저울(Digital
Scale)Sealing기(Packer)
납땜조(Solder Port)P.P.Gage, V/CmΩ/ meter내전압 시험기(Puncture Tester)
PIN이송(State of Pin carried)WAFER 이송(State of Wafer carried)PIN휨(Pin Camber)SENSOR 동작(Sensor function)PIN DETECTOR 동작상태(Pin Detector Function)
수량(Quantity)포장상태(State of Package)
작업표준STD OF WORK
포장관리규칙PackageRegulation
겉모양(Shape)납땜성(Solderability)도금두께(Coating Thickness치수(Dimension)
겉모양(Shape)치수(Dimension)납땜성(Solderability)PIN유지력(Pin retention)
겉모양(Shape)치수(Dimension)형합성(Matching)납땜성(Solderability)PIN 유지력(Pin retention)
체크검사(CHECK)
전수검사(Test of TotalCHECK)체크검사(CHECK)
체크검사(CHECK)계수조정형샘플링MIL-STD-105D
수입검사 규격STD OF INCOMINGINSPECTION
공정 및 최종검사 규격
STD OF PROCESS& FINAL TEST
출하검사 규격STD OF OUTGOING
TEST
YSI-101-005
YSI-091-006
YSI-102-003
YSP-152
YSI-102-100
S.H.Y
03/17
B.J.S
03/17
S.S.S
03/17