Shenzhen KYL Communication Equipment Co., Ltd
KYL-813 wireless switches input and
output module---user manual
Shenzhen KYL Communication Equipment Co., Ltd
Address: C3705-3707, Huangdu Square, South of Exhibition Center, Yitian Road, Futian District, Shenzhen, Guangdong, China 518048
Tel: 86-755-82943662Fax: 86-755-83408785
Skype:KYL-Sunny
Yahoo messenger: [email protected]: [email protected]: [email protected]
Website: http://www.rf-data.com
KYL-813 wireless ON-OFF input and output module is a kind of wireless
Fax: +86-755-83408785 [email protected] www.rf-data.com
![Page 2: C:\Documents And Settings\Administrator\桌面\产品知识\产品介绍English\我的\Kyl 813 User Manual](https://reader035.fdocuments.net/reader035/viewer/2022071700/54b929a14a79598b478b46a6/html5/thumbnails/2.jpg)
Shenzhen KYL Communication Equipment Co., Ltd
transmission equipment with four 2-channel DI and 2-channel relay DO.
I. Function 2-channel ON-OFF DI and DO transmits data timely. The 2-channel
switching condition for the transmitting equipment can be transferred timely to the receiver equipment. That is once the transmitting equipment is switching on; the receiver equipment will be switching on. When the transmitting equipment is switching off, the receiver equipment will be off.
The following is the schematic diagram of the ON-OFF transmission.
Schematic diagram
II、Feature:
1、 2-channel coupler isolated inputs, high reliability and stability.
2、 2-channel relay dry contact output, contact current is 30V 1A.
3、 Collocated with wireless data transmission module whose
transmitting distance is 2-3km. Working frequency 433MHz (400-470MHz);RF power: 500mW;Receiving sensitivity: -123dBm
4、 Receiving current: 30mA; transmitting current: 300mA
5、 Power supply: DC 12V
6、 Features of the output contact is as following: (the parameters
Fax: +86-755-83408785 [email protected] www.rf-data.com
![Page 3: C:\Documents And Settings\Administrator\桌面\产品知识\产品介绍English\我的\Kyl 813 User Manual](https://reader035.fdocuments.net/reader035/viewer/2022071700/54b929a14a79598b478b46a6/html5/thumbnails/3.jpg)
Shenzhen KYL Communication Equipment Co., Ltd
of the relay inside):
III. Exterior sketch map
Fax: +86-755-83408785 [email protected] www.rf-data.com
![Page 4: C:\Documents And Settings\Administrator\桌面\产品知识\产品介绍English\我的\Kyl 813 User Manual](https://reader035.fdocuments.net/reader035/viewer/2022071700/54b929a14a79598b478b46a6/html5/thumbnails/4.jpg)
Shenzhen KYL Communication Equipment Co., Ltd
VI. Connection DefinitionConnection name Pin No. Definition Remarks CN1
1 VCC DC 12V (9-15V)
2 GND Power supply
3 GND
4 INT1
5 GND
6 INT2
7 OUT1A First channel relay output A contact
When the relay shutting,AandB connected
8 OUT1B First channel relay output B contact
9 OUT2A Second channel relay output A contact
When the relay shutting,AandB connected
10 OUT2B Second channel relay output B contact
CN2
1 RXD Receiving data Enter the setting mode for the
module, and the function of the
interface will be effective
2 TXD Transmitting data
3 GND Ground of the signal
4 GND Ground of the signal Programme controlling , low
Fax: +86-755-83408785 [email protected] www.rf-data.com
![Page 5: C:\Documents And Settings\Administrator\桌面\产品知识\产品介绍English\我的\Kyl 813 User Manual](https://reader035.fdocuments.net/reader035/viewer/2022071700/54b929a14a79598b478b46a6/html5/thumbnails/5.jpg)
Shenzhen KYL Communication Equipment Co., Ltd
level. Connect the signal
ground, then will enter the
programme controlling mode
5 PRO SET Programme controlling
6 NC
ANT ANT Antenna port
Fax: +86-755-83408785 [email protected] www.rf-data.com