INFRARED REMOTE CONTROL

Small-size and with excellent ergonomic properties, the Airwell infrared remote control ishighly user friendly. It can be used to program advanced multiple functions such as choosingbetween 3 ventilation speeds, night-time slow running, programming, dehumidification, ener-gy saving function and “I feel” function, and many others. By only pressing a button youselect the temperature to be obtained and controlled with a high degree of precision.

OUTDOOR UNIT GC CD 60 RC RECEIVER RC-4

Page 3: CD 60 - Airwell

By using a communication gateway for connecting several CD 60 indoor units, and with asimple Internet navigator, it is possible to achieve centralised and remote management ofall your indoor units, room by room and floor by floor... In addition to improved comfort andreduced energy bills, thanks to a closer consumption control as well as simplified manage-ment, the AircoNet system requires no special software installation and enables you to bekept informed of any system incident in real time by e-mail or SMS.

Energy label is mostly known for household appliances. It was initiated by the EU to classifythese appliances in 7 categories (from A to G) in relation to their energy consumption.Those appliances with the best energy efficiency are awarded with an A label, those withthe lowest energy efficiency with a G label. This label also includes a certain number of de-tails (Brand, Model, Cooling and Heating capacity, Noise level) and allows you to comparethe efficiency of different products.

DUCTED RANGE

AIRCONET CONTROL SYSTEM

DUCTED RANGE:

CD 60

EnergyManufacturerOutside unit

Annual energy consumptionkWh in cooling mode

Cooling output kW

(Actual consumption will dependon how the appliance is usedand climate)

Energy efficiency ratioFul load (the higher the better)

Type Cooling only

Cooling + Heating

Air-conditioner

Air cooled

Water cooled

Heat output kW

Heating performanceA: higher G: lower

Noise(dB(A) re 1 pW)

Further information is containedin product brochures

Norm EN 814Air-conditionerEnergy Label Directive 2002/31/EC

ABC

DEF

G

AUnside unit

More efficient

Less efficient

RCW2 (Optional)

ENERGY LABEL

R-410A: AN ECO-FRIENDLY FLUIDThe CD 60 DUCTED is available with the ecologically friendlyfluid R410A. This provides high energy efficiency, while pre-serving the ozone layer, and is easily recyclable. Its high den-sity and high energy efficiency make for high performancecoefficients, thereby providing significant energy saving

RCW2 REMOTE CONTROL (OPTIONAL)This mini control unit is designed to manage systemoperation and temperature control of both individualand medium size heating, ventilation and air condition-ing installations. Being easy to use, it provides effectivemanagement of from 1 to 15 different temperaturezones. With the mini control unit, and its easy to under-stand programming process, the user can alter the settemperatures for heating and cooling modes and selectventilation fan speeds in each of the controlled zones.

PRODUCT BENEFITS

• Suspended ceiling installation.• Horizontal mounting.• Reusable air filter.• High available static pressure.

• Pressure available for connection to a duct network.

• Supplied with RC4 remote control.• Wall mounted RCW2 remote control (Optional).

The CENTRIFUGAL DUCTED 60 has been designed to answer to many constraints and is spe-cially suited to light commercial sector applications, meeting the air conditioning requirements inmedium and large size rooms. This unit can blend into any interior design as it provides a widerange of applications by allowing air outlets to be conveniently installed anywhere in the ceiling.The installation of the indoor and outdoor units offers a great flexibility and a wide range of fittingoptions due to connection facilities (up to 50 m cooling pipe). Efficient, simple, discreet, CD 60ensures a quiet operation, easy maintenance and control to offer the ultimate comfort to users.

c

Page 4: CD 60 - Airwell

CD 60DUCTED RANGE

CM C

D60

1 - A

.1 M

ASTE

R - S

pecif

icatio

ns su

bjec

t to

chan

ge w

ithou

t not

ice. P

ictur

es n

on co

ntra

ctua

l.

Airwell Group

1, Bis Avenue du 8 mai 1945Saint Quentin en Yvelines78284 GUYANCOURTFranceTel. +33 (0)139 44 78 00Fax +33 (0)139 44 6517

[email protected]

Your official dealer

Indoor UnitOutdoor UnitCapacity kWPower input kWEER/Energy LabelOperating limits °CCapacity kWPower input kWCOP/Energy LabelOperating limits °CSound pressure level 1 mt1 dB(A)Sound power level1 dB(A)Airflow 1 m3/hExternal static pressure2 PaDehumidification l/hDimensions (WxDxH) mmWeight kgSound pressure level 1 mt1 dB(A)Sound power level1 dB(A)Airflow m3/hCompressor typeDimensions (WxDxH) mmWeight kgPower supply sidePower cable section mm2

Fuse rating am AElectrical connections mm2

Suction pipe diameter inchesLiquid pipe diameter inchesMax lenght mMax height m

Cooling

Heating

Indoorunit

Power supply3-400V - 50Hz

Pipeline

Outdoorunit

ST CD 60GC CD 60 RC16.45.522.97/C21°/ 46° Dry Bulb18.15.173.5/B-9°/ 24° Dry Bulb55/59/6167/71/73 2430/3050/3265120/2004.61350x400x6407556/6264/704650/5500Scroll900x340x1255110Outdoor5x2.53x206x1.57/8”1/2”5025

CD 60

1Data are relative to Low speed, Medium speed and High speed2Nominal/Max