Ethernet Provides the Solution for Broadband Subscriber Access
CATV & Broadband Solution Alantek
description
Transcript of CATV & Broadband Solution Alantek
-
5/21/2018 CATV & Broadband Solution Alantek
1/25
CATV & Broadband Solution
-
5/21/2018 CATV & Broadband Solution Alantek
2/25
Coaxial Cables
Cable Constructions
CATV cable is the physical foamed PE cable with high frequency and low loss used mainly for Satellite TV
system. The spec of our cable can be designed according to customer's requirements.
-
5/21/2018 CATV & Broadband Solution Alantek
3/25
RG59 Series Drop Cables
Part # Description
301-RG5900-SS00 RG59 Standard Shield 75Coaxial Cables
301-RG5900-3S00 RG59 Tri-Shield 75Coaxial Cables
301-RG5900-QS00 RG59 Quad-Shield 75Coaxial Cables
Product Description
20 AWG, 0.032in. (0.81mm) Copper or Copper CoveredSteel Center Conductor
Gas Expanded Polyethylene Dielectric Inner Shield Aluminum-Polypropylene-Aluminum
laminated tape with overlap bonded to dielectric
Outer Shield 34 AWG Aluminum or Tinned Copper wirebraid shield
Outer Jacket of Polyvinylchloride or Polyethylene(flooded)
Nominal O.D. 0.24in (6.10mm)
Cable Physical Construction
ComponentStandard Shield Tri-Shield Quad-Shield
Inches mm Inches mm Inches mm
Nominal Center
Conductor Diameter0.032 0.81 0.032 0.81 0.032 0.81
Nominal Diameter
Over Dielectric 0.144 3.66 0.144 3.66 0.144 3.66
Norminal DiameterOver First Shield
(Tape)
0.151 3.84 0.151 3.84 0.151 3.84
Norminal Diameter
Over Jacket0.240 6.10 0.240 6.10 0.265 6.73
Norminal Jacket
Wall Thickness0.032 0.81 0.030 0.76 0.034 0.86
Norminal Diameter
of Steel Messenger
0.051(single) 1.30 0.051(single) 1.30 0.051(single) 1.30
0.072(dual) 1.83 0.072(dual) 1.83 0.072(dual) 1.83
Shield : Foil Aluminum Laminated Foil, Bonded to Dielectric
Shield : 2nd Foil N/AAlu. LaminatedFoil
Alu. Laminated Foil
Braid : Aluminum Wire, 60% Coverage
Braid : 2nd Braid N/A N/AAluminum Wire, 35%
Coverage
-
5/21/2018 CATV & Broadband Solution Alantek
4/25
RG6 Series Drop Cables
Part # Description
301-RG060X-SS00 RG6 Standard Shield 75Coaxial Cables
301-RG060X-3S00 RG6 Tri-Shield 75Coaxial Cables
301-RG060X-QS00 RG6 Quad-Shield 75Coaxial Cables
Subsitute X: M(Messenger), F(Flooding Compound), D(Dual).
Product Description
18 AWG, 0.040in. (1.02mm) Copper or Copper Covered
Steel Center Conductor
Gas Expanded Polyethylene Dielectric Inner Shield Aluminum-Polypropylene-Aluminum
laminated tape with overlap bonded to dielectric
Outer Shield 34 AWG Aluminum or Tinned Copperwire braid shield
Outer Jacket of Polyvinylchloride or Polyethylene(flooded)
Nominal O.D. 0.272in. (6.91mm)
Cable Physical Construction
ComponentStandard Shield Tri-Shield Quad-Shield
Inches mm Inches mm Inches mm
Nominal Center
Conductor Diameter 0.040 1.02 0.040 1.02 0.040 1.02
Nominal Diameter
Over Dielectric0.180 4.57 0.180 4.57 0.180 4.57
Norminal DiameterOver First Shield
(Tape)
0.187 4.75 0.187 4.75 0.187 4.75
Norminal Diameter
Over Jacket0.272 6.91 0.278 7.06 0.300 7.62
Norminal Jacket
Wall Thickness0.030 0.76 0.030 0.76 0.034 0.86
Norminal Diameter
of Steel Messenger
0.051(single) 1.30 0.051(single) 1.30 0.051(single) 1.30
0.072(dual) 1.83 0.072(dual) 1.83 0.072(dual) 1.83
Shield : Foil Aluminum Laminated Foil, Bonded to Dielectric
Shield : 2nd Foil N/AAlu. LaminatedFoil
Alu. Laminated Foil
Braid : Aluminum Wire, 60% Coverage
Braid : 2nd Braid N/A N/AAluminum Wire, 42%
Coverage
-
5/21/2018 CATV & Broadband Solution Alantek
5/25
RG11 Series Drop Cables
Part # Description
301-RG110X-SS00 RG11 Standard Shield 75Coaxial Cables
301-RG110X-3S00 RG11 Tri-Shield 75Coaxial Cables
301-RG110X-QS00 RG11 Quad-Shield 75Coaxial Cables
Subsitute X: M(Messenger), F(Flooding Compound), D(Dual).
Product Description
14 AWG, 0.064in. (1.63mm) Copper or Copper Covered Steel
Center Conductor
Gas Expanded Polyethylene Dielectric Inner Shield Aluminum-Polypropylene-Aluminum
laminated tape with overlap bonded to dielectric
Outer Shield 34 AWG Aluminum or Tinned Copperwire braid shield
Outer Jacket of Polyvinylchloride or Polyethylene(flooded)
Nominal O.D. 0.395in. (10.03mm)
Cable Physical Construction
ComponentStandard Shield Tri-Shield Quad-Shield
Inches mm Inches mm Inches mm
Nominal CenterConductor Diameter 0.064 1.63 0.064 1.63 0.064 1.63
Nominal Diameter
Over Dielectric0.280 7.11 0.280 7.11 0.280 7.11
Norminal DiameterOver First Shield
(Tape)
0.287 7.29 0.287 7.29 0.287 7.29
Norminal Diameter
Over Jacket0.395 10.03 0.395 10.03 0.405 10.29
Norminal Jacket WallThickness
0.042 1.07 0.039 0.99 0.037 0.94
Norminal Diameter ofSteel Messenger
0.072(single) 1.83 0.072(single) 1.83 0.072(single) 1.83
0.109(dual) 2.77 0.109(dual) 2.77 0.109(dual) 2.77
Shield : Foil Aluminum Laminated Foil, Bonded to Dielectric
Shield : 2nd Foil N/A Alu. Laminated Foil Alu. Laminated Foil
Braid : Aluminum Wire, 60% Coverage
Braid : 2nd Braid N/A N/A
Aluminum Wire, 40%
Coverage
-
5/21/2018 CATV & Broadband Solution Alantek
6/25
AC-540 Series Trunk Cables
Part # Description
301-OAC540-
0000AC-540 75Coaxial Trunk Cable with Messenger
301-OAC540-
NM00AC-540 75Coaxial Trunk Cable without Messenger
301-OAC540-
NMF0
AC540 75Coaxial Trunk Cable with Flooding Compound,
No Messenger
Product Description
0.124in (3.15mm) Copper or Copper Coveredcenter conductor
Gas Expanded Polyethylene Dielectric Continuous Aluminum Outer Conductor Flame Retardant Polyethylene (PE) jacket Nominal O.D. 0.610in. (15.49mm)
Cable Physical Construction
Component Inches mm
Nominal Center Conductor
Diameter0.124 3.150
Nominal Diameter Over Dielectric 0.514 13.030
Norminal Diameter Over Outer
Conductor 0.540 13.720
Norminal Outer Conductor
Thickness0.014 0.343
Norminal Diameter Over Jacket 0.610 15.490
Norminal Jacket Wall Thickness 0.035 0.890
Messenger Version
Diameter of Steel Messenger 0.109 2.770
-
5/21/2018 CATV & Broadband Solution Alantek
7/25
CATV Accessories
Optical Transmitters and EDFA
30F-N1185X-ETXX1550nm External
Modulation
Transmitter
30F-N1188X-
EDFA1550nm EDFA
30F-N1285X-1550
1550nm transmitter30F-N1283X-1310
1310nm transmitter
Features and Specifications
High quality, high linearity pump & DFB lasers Wide working bandwidth 45860MHz Output power tunable Advanced RF pre-distortion function AGC technology adopted to the RF input Micro-processor can conduct status monitoring Panel display for working status RS-232 interface for remote monitoring 19 inch standard chassis switch power supply
Part #30F-N1185X-
ETXX
30F-N1188X-
EDFA
30F-N1285X-
155030F-N1283X-
1310
Optical Wavelength (nm) 155010 155010 155010 131020
Optical output (mw) 3,5,7,914,16,17,18, 19,
20, 21, 22, 23
2, 3, 4, 5, 6,
7, 8, 9, 10
10,12,14,
16,18, 20
Optical connector Type FC/APC FC/APC FC/APC FC/APC
Suppression Threshold (dBm) 13-18 / / /
Operating Bandwidth (MHz) 45-860 / 45-860 45-860
Channel number 110CH (NTSC) / 110CH (NTSC) 110CH (NTSC)
Input Impedance () 75 / 75 75
Input Return Loss (dB, min) 16 / 16 16
RF Input Level (dBV/ch) 7585 / 7585 803
Optical input /-3 to +7dB
Typical +3dB/ /
OMI 30.25% / 30.25% 30.25%
Flatness (dB) 0.75 / 0.75 0.75
Input Connector Type F type / F type F type
Link Performance CNR (dB) 52 / 52 52
-
5/21/2018 CATV & Broadband Solution Alantek
8/25
Link Performance CSO (dB) - 65 / - 65 - 65
Link Performance CTB (dB) - 65 / - 65 - 60
Power Supply 90260V50/60 90260V50/60 90260V50/60 90260V50/60
Optical Receivers
30F-N1381X-FIRXIndoor Optical Receiver
30F-N1382X-FORXOutdoor Optical Receiver
30F-N1384X-FORXOutdoor Optical Receiver
Features and Specifications
Leading brand photo-electronic converters Low noise amplifying module RF bandwidth up to 860MHz Supporting 1310nm and 1550nm two windows operation Excellent switching power supply Optical attenuator and power indicator inside.
Part # 30F-N1381X-FIRX 30F-N1382X-FORX 30F-N1384X-FORX
Input Optical Power (dBm) -4+2 -7+2 -7+2
Optical Return Loss (dB) >45 >55 >55
Wavelength (nm) 11001600 11001600 11001600
Optical Fiber Connector FC/APC FC/APC FC/APC
Operating Fiber Type One Pattern One Pattern One Pattern
RF Frequency Band (MHz) 45860 45860 45860
RF Flatness In Band (dB) 0.75 0.75 0.75
RF Output Level (dBV) 84104 84104 84104
C/N Carrier To Noise Ratio 51 51 51
CTB (@84 PAL-D Channels)(dB)
-60 -65 -65
CSO (@84 PAL-D Channels)
(dB)-60 -62 -62
Return Loss (dB)47~550MHz: 16550~750MHz: 14
47~550MHz: 16550~750MHz: 14
47~550MHz: 16550~750MHz: 14
-
5/21/2018 CATV & Broadband Solution Alantek
9/25
Output Impedance () 75 75 75
Thunder Stroke Immunity (KV) 5(10/700S) 5(10/700S) 5(10/700S)
RF output Port 2 2 4
Modulators
308-N3151X-FMXXFixed channel Modulator
308-N3182X-FMXXFixed channel Modulator
308-N3282X-AMXXAgile Channel Modulator
Features and Specifications
Superior vestigial sideband filtering for adjacent channel systems Low spurious harmonic output Highly accurate crystal controlled oscillator 5 digits LED on Front panel Front panel keys for adjusting frequency, modulation level, A/V ratio,
volume, RF signal level
-25 dB test point on Rear panel GaAs Component used for 308-N3282X-AMXX System: PAL-B/G/D, NTSC
Part #308-N315X-
FMXX
308-N3182X-
FMXX
308-N3282X-
AMXX
RF
Output
Frequency range(MHz)
47-550 47-860 45-860
Frequencystability (KHz)
10 10 5
Tuning step
(KHz)/ / 250
Output level (dBV)
100 105 108
Output level
adjustable (dB)0 to -20 0 to -20 0 to -20
Output return loss
(dB)14 14 13
Spurious output(dB)
-62 -62 -60
C/N Ratio in
Channel (dB)65 65 65
Audio/ video
carrier ratio
adjustable
-10 to -20 dB /
-
5/21/2018 CATV & Broadband Solution Alantek
10/25
Output impedance()
75 75 75
Video
Section
Standard input
level (V p-p)0.5 0.5 1.0
Input impedance
()75 75 75
Video S/N ratio
(dB)53 60 50
Video Response
(dB)1.0 1.5 1.5
Differential Gain
-
5/21/2018 CATV & Broadband Solution Alantek
11/25
Zinc die cast housing, nickel-plated Screening factor: 30-300MHz 85dB
300-470MHz 80dB
470-1000MHz 75dB
Bandwidth: 5-1000MHz Low insertion loss, high return loss and isolation FR4 PCB for consistency of specifications in all bandwidth High quality ferrites, SMD resistors and capacitors Each unit is individually packed in PE bag
Grounding terminal provided All ports DC block; Connector: F female, 75
Part #
Insertion Loss (dB, max) Out to Out Isolation (dB, min)
5-65MHz
65-
550MHz
550-
750MHz
750-
1000MHz
5-65MHz
65-
550MHz
550-
750MHz
750-
1000MHz
Two Way Splitter
308-N5172X-ISXX 3.2 3.5 3.8 4.2 35.0 32.0 30.0 30.0
Three Way Splitter
308-N5173X-
ISXX4.9 5.2 5.7 6.0 30.0 30.0 30.0 28.0
Four Way Splitter
308-N5174X-ISXX
6.6 7.0 7.6 7.7 32.0 32.0 30.0 28.0
Six Way Splitter
308-N5176X-ISXX
8.2 9.0 9.8 10.4 29.0 27.0 26.0 26.0
Eight Way Splitter
308-N5178X-ISXX
10.1 10.6 11.4 12.5 27.0 35.0 31.0 26.0
Ten Way Splitter*
308-N5150X-10SX 11.4 11.9 12.4 14.0 21.0 24.0 24.0 21.0
Twelve Way Splitter*
308-N5152X-12SX 11.5 12.1 12.6 14.0 21.0 24.0 24.0 21.0Fourteen Way Splitter*
308-N5154X-14SX 15.0 16.0 16.0 17.0 21.0 24.0 24.0 21.0
Sixteen Way Splitter*
308-N5156X-16SX 15.0 16.0 16.0 17.0 21.0 24.0 24.0 21.0
* Low inter-modulation drop splitter with high voltage capacitor at every port
-
5/21/2018 CATV & Broadband Solution Alantek
12/25
CATV Drop Taps
308-N5271X-ITXXOne Way Tap
308-N5272X-ITXX
Two Way Tap308-N5273X-ITXX
Three Way Tap308-N5274X-ITXX
Four Way Tap
308-N5276X-ITXXSix Way Tap
308-N5278X-ITXXEight Way Tap
Features and Specifications
Zinc die cast housing, nickel-plated Screening factor: 30-300MHz 85dB
300-470MHz 80dB
470-1000MHz 75 dB Bandwidth: 5-1000MHz Low insertion loss, high return loss and isolation FR4 PCB for consistency of specifications in all bandwidth High quality ferrites, SMD resistors and capacitors Each unit is individually packed in PE bag Grounding terminal provided All ports DC block; Connector: F female, 75
-
5/21/2018 CATV & Broadband Solution Alantek
13/25
Low Inter-modulation Drop Taps
308-N5291X-ITXX
One Way Tap
308-N5292X-ITXX
Two Way Tap
308-N5293X-ITXX
Three Way Tap
308-N5294X-ITXXFour Way Tap
308-N5296X-ITXXSix Way Tap
308-N5298X-ITXXEight Way Tap
Features and Specifications
Zinc die cast housing, bright tin finish and concave solder back RFI110dB Bandwidth: 5-1000MHz FR4 PCB for consistency of specifications in all bandwidth High quality ferrites, SMD resistors and capacitors Each unit is individually packed in PE bag High voltage capacitor every port Return loss all ports: 5-750MHz, 18dB min; 750-1000MHz, 16dB min All ports DC block; Connector: F female 75
-
5/21/2018 CATV & Broadband Solution Alantek
14/25
Outdoor Splitters and Directional Couplers
3CN-N4112X-OSXX2 Way Splitter
3CN-N4113X-OSXX3 Way Splitter
3CN-N4113B-OSXX3 Way Splitter (Balance)
3CN-N4121X-OCXX1 Way Directional Coupler
3CN-N4122X-OCXX2 Way Directional Coupler
3CN-N4131X-OPIXPower Inserter
Features and Specification
Aluminum alloy housing is finished with a baked acrylic paint FR4 PCB for consistency of specifications in all bandwidth High quality ferrites, SMD resistors and capacitors Return loss all ports: 5-750MHz:18dB,750-1000 MHz:16dB Hum modulation at 10 Amps: 70dB min All port power passing: 15 Amps 60VAC Impedance: 75all ports Aerial or pedestal installation with 5/8 port entry The 100dB RF integrity is maintained by the use of tongue and groove
design and with a stainless steel mesh RF gasket.
-
5/21/2018 CATV & Broadband Solution Alantek
15/25
Outdoor Taps
308-N4422X-OTXXTwo Way Tap
308-N4424X-OTXXFour Way Tap
308-N4428X-OTXXEight Way Tap
Features and Specifications
Aluminum alloy housing is finished with a baked acrylic paint Continual power through between input and output. Neoprene sealed and nickel-plated brass for all taps F-(f) port Aerial or pedestal installation with 5/8 port entry Tongue and groove design and with a stainless steel mesh RF gasket to
ensure 100dB RFI integrity
FR-4 PCB for consistency of specifications in all bandwidth High quality ferrites, SMD resistors and capacitors Return loss all ports: 5-750MHz: 18dB min
750-1000MHz: 16dB min
Hum modulation at 10 Amps: 60dB min In-Out Power passing: 12 Amps 60VAC Impedance: 75all ports
-
5/21/2018 CATV & Broadband Solution Alantek
16/25
Trunk Line and Drop Distribution Amplifiers
308-N2218X-2TAXTwo Way Trunk
Amplifier
308-N2118X-
LEXXLine Extender
308-N2228X-2IMX
Two Way Indoor
Amplifier
308-N2128X-IDAX
Indoor Distribution
Amplifier
Features and Specifications
High quality hybrid amplification module system at 54/87- 860MHzbandwidth for forward direction and 5-40/65MHz for reverse path.
For two way amplifier: Plug-in duplex filters are capable of two wayTransmission; Reverse bandwidth 5-40/ 5-65 optional
Two outputs which can plug-in direction coupler to change output value. Both the input and output have testing points (-20dB). Input, outputs are all equipped with arrestors that reduce mechanical
breakdowns from sudden electrical surges
Trunk line amplifiers allow forward, backward power supply Uses high efficiency transformer / switch power
Part # 308-N2218X-2TAX308-
N2118X-
LEXX
308-N2228X-2IMX
308-
N2128X-
IDAX
Path Forward Reverse Forward Forward Reverse Forward
Amplifying Module
Push-pull +
Power
doubler
Push-
pullPush-pull
Push-pull +
Power
doubler
Push-
pullPush-pull
Frequency Band (MHz) 54/87-860 5-40/65 47-860 54/87-86047-
40/6547-860
Max Gain(dB) 330.5 180.5 330.5 330.5 330.5 330.5
Flatness(dB) 0.75 0.75 0.5 0.5 0.5 0.5
Rated Input Level (dBV) 70 70 70 70 70 70
Rated Output Level (dBV) 102 95 98 98 98 98
CSO (dB) (@84 PAL-D Channel) (dB -52 -52 -52 -52 -52 -52
CTB (dB) (@84 PAL-D Channel) (dB -51 -51 -51 -51 -51 -51
HUM Modulation(dB) -50 -50 -50 -50 -50 -50
Noise figure(dB) 7 7 7 7 7 7
Return Loss(dB) 16 16 15 16 16 15
Gain Attenuation(dB)
0, 3, 6,
9,12
0, 3, 6,
9,12 018
0, 3, 6,
9,12
0, 3, 6,
9,12 018
-
5/21/2018 CATV & Broadband Solution Alantek
17/25
Tilt Tunable(dB) 0, 3, 6, 90, 3, 6,
9117 0, 3, 6, 9
0, 3, 6,9
117
Power Supply 60V 220/120VAC optional
Impedance (ohm) 75 75 75 75 75 75
Connectors
3CN-0FY024-RG06RG6 crimp w/ Silicon &
'O' Ring
3CN-0FY040-RG06RG6 compression
3CN-0FY079-RG06RG6 BNC crimp
3CN-
0FY028-
RG11RG11 crimp
3CN-0FY048-RG11RG11 compression
3CN-0FY079-RG59RG59 BNC crimp
302-0FY036-0000Tool for RG6 & RG11
crimp type
302-0FY050-
0000Tool for RG6,
RG11 &RG59,
compression
type
3CN-N703X-500P500 pin type
3CN-N7032X-500F500 F type
3CN-N7033X-500T500 feed thru
3CN-
N7034X-
500S500 splice
3CN-N7041X-540P540 pin type
3CN-N7042X-540F540 F type
3CN-N7043X-540T540 feed thru
3CN-
N7044X-
540S540 splice
3CN-N7051X-565P565 pin type
3CN-N7052X-565F565 F type
3CN-N7053X-565T565 feed thru
3CN-
N7054X-
565S
-
5/21/2018 CATV & Broadband Solution Alantek
18/25
565 splice
3CN-N7081X-FFFSF f-f splice
3CN-N7085X-FMTX
F male 75 ohm
terminator
3CN-N7086X-FMLXF male lock
3CN-
N7091X-
58FF5/8 to F
female
3CN-N7092X-PPXXPin to Pin
3CN-N7093X-O75TOutdoor 75 ohm
terminator
3CN-N7094X-90AX90adaptor
3CN-
N7101X-
GW1FGround block
W/1 F-81
3CN-N7102X-GW2FGround block W/2 F-81
3CN-N7104X-GW4F
Ground block W/4 F-81FM & TV Faceplate
308-TV8520-0000
-
5/21/2018 CATV & Broadband Solution Alantek
19/25
RF 50 Feeder Cables
1 1/4 Low Loss Foamed Insulation Coaxial Cable
Part # Description
301-RF1140-0000 50RF 1-1/4 Low Loss Foamed Insulation Coaxial Cable
Product Description
Smooth Copper Tube Inner Conductor
80% Foamed Polyethylene Insulation
Ring Corrugated Copper Outer conductor LLDPE Outer Jacket
Provide low attenuation and stability
Provide effective moisture protection
Construction
Inner ConductorMaterial Smooth Copper Tube
Diameter, mm 13.10 0.05
InsulationMaterial Foamed PE
Diameter, mm 32.80 0.40
Outer ConductorMaterial Ring Corrugated Copper
Diameter, mm 35.80 0.30
JacketMaterial LLDPE
Diameter, mm 39.40 0.50
Mechanical Properties
Bending Radius, mm Single 200
Repeated 380
Moving -
Pulling Strength, N 5900
Crush Reisitance, kg/mm 2.2
Temperature, C
Storage -70 ~ +85
Installation -40 ~ +60
Operation -55 ~ +85
Electrical Properties
Impedance, 50 1
Capacitance, PF/m 75
Propagation Velocity, % 89
DC Breakdown Voltage, kV 9
Insulation Resistance, M.km > 5 x 10
-
5/21/2018 CATV & Broadband Solution Alantek
20/25
Peak Power, kW 205
Screening Attn., dB >> 120
Cut-off Frequency, GHz 3.3
1/2 Low Loss Foamed Insulation Coaxial Cable
Part # Description
301-RF0120-0000 50RF 1/2 Low Loss Foamed Insulation Coaxial Cable
Product Description
Copper Cladded Aluminium Inner
Conductor 80% Foamed Polyethylene Insulation
Ring Corrugated Copper Outer Conductor
LLDPE Outer Jacket
Provide low attenuation and stability Provide effective moisture protection
Construction
Inner ConductorMaterial Copper Cladded Aluminium
Diameter, mm 4.80 0.05
InsulationMaterial Foamed PE
Diameter, mm 12.20 0.30
Outer ConductorMaterial Ring Corrugated Copper
Diameter, mm 13.80 0.20
JacketMaterial LLDPE
Diameter, mm 15.80 0.20
Mechanical Properties
Bending Radius, mm Single 70
Repeated 125
Moving 350Pulling Strength, N 1130
Crush Reisitance, kg/mm 2
Temperature, C
Storage -70 ~ +85
Installation -40 ~ +60
Operation -55 ~ +85
Electrical Properties
Impedance, 50 1
-
5/21/2018 CATV & Broadband Solution Alantek
21/25
Capacitance, PF/m 75.8
Propagation Velocity, % 88
DC Breakdown Voltage, kV 4
Insulation Resistance, M.km > 5 x 10
Peak Power, kW 40
Screening Attn., dB >> 120
Cut-off Frequency, GHz 8.8
1/2 Flexible Foamed Insulation Coaxial Cable
Part # Description
301-RF012S-0000 50RF 1/2 Flexible Foamed Insulation Coaxial Cable
Product Description
Copper Cladded Aluminium Inner
Conductor
80% Foamed Polyethylene Insulation
Helically Corrugated Copper OuterConductor
LLDPE Outer Jacket Provide low attenuation and stability
Provide effective moisture protection
Construction
Inner ConductorMaterial Copper Cladded Aluminium
Diameter, mm 3.60 0.04
InsulationMaterial Foamed PE
Diameter, mm 8.80 0.20
Outer ConductorMaterial Helically Corrugated Copper
Diameter, mm 12.20 0.20
JacketMaterial LLDPE
Diameter, mm 13.40 0.20
Mechanical Properties
Bending Radius, mm Single 25
Repeated 30
Moving 200
Pulling Strength, N 800
Crush Reisitance, kg/mm 1.9
Temperature, C Storage -70 ~ +85
-
5/21/2018 CATV & Broadband Solution Alantek
22/25
Installation -40 ~ +60
Operation -55 ~ +85
Electrical Properties
Impedance, 50 1
Capacitance, PF/m 82
Propagation Velocity, % 81
DC Breakdown Voltage, kV 2.5
Insulation Resistance, M.km > 5 x 10
Peak Power, kW 15.6
Screening Attn., dB >> 120
Cut-off Frequency, GHz 10.2
7/8 Low Loss Foamed Insulation Coaxial Cable
Part # Description
301-RF0780-0000 50RF 7/8 Low Loss Foamed Insulation Coaxial Cable
Product Description
Smooth Copper Tube Inner Conductor
80% Foamed Polyethylene Insulation
Ring Corrugated Copper Outer conductor
LLDPE Outer Jacket Provide low attenuation and stability
Provide effective moisture protection
Construction
Inner ConductorMaterial Smooth Copper Tube
Diameter, mm 8.95 0.05
InsulationMaterial Foamed PE
Diameter, mm 22.50 0.40
Outer ConductorMaterial Ring Corrugated Copper
Diameter, mm 24.90 0.30
JacketMaterial LLDPE
Diameter, mm 27.30 0.20
Mechanical Properties
Bending Radius, mm Single 120
Repeated 250
Moving 500
-
5/21/2018 CATV & Broadband Solution Alantek
23/25
Pulling Strength, N 1470
Crush Reisitance, kg/mm 1.4
Temperature, C
Storage - 70 ~ +85
Installation - 40 ~ +60
Operation -55 ~ +85
Electrical Properties
Impedance, 50 1
Capacitance, PF/m 75
Propagation Velocity, % 88
DC Breakdown Voltage, kV 6
Insulation Resistance, M.km > 5 x 10
Peak Power, kW 91
Screening Attn., dB >> 120
Cut-off Frequency, GHz 5
7/8 Flexible Foamed Insulation Coaxial Cable
Part # Description
301-RF078S-0000 50 RF 7/8 Flexible Foamed Insulation Coaxial Cable
Product Description
Helically Corrugated Copper Inner
Conductor 80% Foamed Polyethylene Insulation
Ring Corrugated Copper Outer conductor LLDPE Outer Jacket
Provide low attenuation and stability Provide effective moisture protection
Construction
Inner ConductorMaterial Helically Corrugated Copper
Diameter, mm 9.42 0.10
InsulationMaterial Foamed PE
Diameter, mm 22.50 0.40
Outer ConductorMaterial Ring Corrugated Copper
Diameter, mm 12.20 0.20
JacketMaterial LLDPE
Diameter, mm 27.50 0.40
Mechanical Properties
-
5/21/2018 CATV & Broadband Solution Alantek
24/25
Bending Radius, mm Single 40
Repeated 125
Moving -
Pulling Strength, N 1020
Crush Reisitance, kg/mm 1.4
Temperature, C
Storage -70 ~ +85
Installation -40 ~ +60
Operation -55 ~ +85
Electrical Properties
Impedance, 50 1
Capacitance, PF/m 74.2
Propagation Velocity, % 83
DC Breakdown Voltage, kV 6
Insulation Resistance, M.km > 5 x 10
Peak Power, kW 90
Screening Attn., dB >> 120
Cut-off Frequency, GHz 4.9
-
5/21/2018 CATV & Broadband Solution Alantek
25/25