    Catalyst 5000 SeriesSupervisor Engine III G Installation andConguration Note

    Product Numbers:WS-X5550(=) Supervisor Engine III G without Uplink Module

    This conguration note contains procedures for installing and verifying the operation of theCatalyst 5000 series Supervisor Engine III G.

    ContentsThis document contains the following sections:

    Supervisor Engine III G Overview, page 2 Supervisor Engine III G Front Panel Components, page 2 Safety Recommendations, page 6 Removing and Replacing the Supervisor Engine, page 7

    Connecting a Terminal to the Console Port, page 10 Connecting to the Interface Ports, page 12 Verifying System Operation, page 14 FCC Class A Compliance, page 15 Related Documentation, page 15 Cisco Connection Online, page 16 Documentation CD-ROM, page 17

    78-6525-01 Rev. A0

  • 8/6/2019 Catalyst 5505

    2/18

    2 Catalyst 5000 Series Supervisor Engine III G Installation and Conguration Note

    Supervisor Engine III G Overview

    Supervisor Engine III G OverviewSupervisor Engine III G includes the following features:

    Bridge address table for up to 16,000 active Media Access Control (MAC) addresses andassociated virtual local-area networks (VLANs) allocated dynamically between active ports

    Switching engine that provides data path and control for all network interfaces including twointegrated FastEthernet interfaces that can support redundancy using the spanning-tree algorithmor load sharing when used with VLANs

    Gigabit Ethernet multimode ber (MMF) or single-mode ber (SMF) interfaces usingSC connectors

    Management functions that include monitoring the interface and environmental status andproviding Simple Network Management Protocol (SNMP) management and theconsole/Telnet interface

    37.5-MHz MCF5102 Network Management Processor (NMP) Switch fabric interface with a capability of over one million packets per second (pps) Hardware support for up to 1024 VLANs Gigabit Interface Converter (GBIC)-based uplink ports Onboard NetFlow Feature Card II (NFFC II) chipset for core switching logic

    Supervisor Engine III G Front Panel ComponentsThe Supervisor Engine III G front panel is shown in Figure 1.

    Figure 1 Supervisor Engine III G

    LEDsThe LEDs on the supervisor engine front panel indicate the status of the system, which includes thestates of the supervisor engine, the power supplies, and the fan assembly. Table 1 describes theLEDs.

    Table 1 LED Descriptions

    LED State Description

    SYSTEMSTATUS

    Indicates the status of the switch based on a series of self-tests anddiagnostic tests.

    Green All the tests pass.

    Red Any test fails.

    1 8 9 3 7

    S Y S T

    E M

    S T A T

    U S 1 0 0 %

    R E S E

    T F A

    N S W I T C

    H

    L O A D

    1 %

    A C T I V

    E

    P S 1

    P S 2

    SUPERVISOR ENGINE III G-SERIES

    WS-X5550

    LINK

    PORT 1 PORT 2

    LINK

    CONSOLE

    CONSOLEPORTMODE

    RSFC CONSOLE

    Uplink ports withGBIC fiber-optic connections

    Console ports

    StatusLEDs

    Resetbutton

    SwitchLoad display

  • 8/6/2019 Catalyst 5505

    3/18

    Catalyst 5000 Series Supervisor Engine III G Installation and Configuration Note 3

    LEDs

    SYSTEMSTATUS

    (continued)

    Red During system boot or if the module is disabled.

    Orange The redundant power supply is installed but not turned on or receiving input.

    Orange The fan module fails.

    FAN Indicates the status of whether or not the fan is operational.

    Green The fan is operational.

    Red The fan is not operational.

    PS1 Indicates the status of the power supply in the left bay.

    Catalyst 5000, Catalyst 5505, Catalyst 5509, and Catalyst 5500 switches:

    Green The power supply in the left bay is operational.

    Red The power supply in the left bay is not operational, switched off, or not

    receiving input power.Off The power supply in the left bay is off or not installed.

    Note The Catalyst 5500 power supply LED is red when no modules areinstalled.

    Catalyst 5002 switch:

    Green The power supply associated with the PS1 AC receptacle or DC terminalblock is operational.

    Red The power supply associated with the PS1 AC receptacle or DC terminalblock is not receiving input power.

    PS2 Indicates the status of the power supply in the right bay.

    Catalyst 5000, Catalyst 5505, Catalyst 5509, and Catalyst 5500 switches:

    Green The power supply in the right bay is operational.

    Red The power supply in the right bay is not operational, switched off, or notreceiving input power.

    Off The power supply in the right bay is off or not installed.

    Note The Catalyst 5500 power supply LED is red when no modules areinstalled.

    Catalyst 5002 switch:

    Green The power supply associated with the PS2 AC receptacle or DC terminalblock is operational.

    Red The power supply associated with the PS2 AC receptacle or DC terminalblock is not receiving input power.

    SWITCH LOAD 1-100% If the switch is operational, the switch load display indicates (as anapproximate percentage) the current trafc load over the backplane (seeFigure 2 ).

    ACTIVE Green The supervisor engine is operational and active.

    Orange The supervisor engine module is in standby mode.

    100 Mbps Green The port is operating at 100 Mbps.

    1000 Mbps Green The port is operating at 1000 Mbps.

    Table 1 LED Descriptions (continued)

    LED State Description

  • 8/6/2019 Catalyst 5505

    4/18

    4 Catalyst 5000 Series Supervisor Engine III G Installation and Conguration Note

    Supervisor Engine III G Front Panel Components

    Reset ButtonThe Reset button allows you to restart the switch.

    Note Use a paper clip or other small, pointed object to access the Reset button.

    Switch LoadThe Switch Load display provides you with a visual approximation of the current trafc load acrossthe backplane. The Supervisor Engine III G Switch Load display indicates the current aggregatetrafc load across all buses. Figure 2 shows the appearance of the Switch Load display.

    Figure 2 Switch Load Display

    Console and RSFC Console PortsThe console port and RSFC console port allow you to perform the following functions:

    The console port enables you to congure the switch from the CLI Monitor network statistics and errors Congure SNMP agent parameters

    Download software updates to theswitch or distribute software images residing in Flash memoryto attached devices

    The RSFC console port enables you to congure the switch for multiprotocol routing usingCisco IOS software.

    The console port and RSFC console port are EIA/TIA-232 asynchronous, serial, full-featured dataterminal equipment (DTE) connections with hardware ow control and RJ-45 connectors. A consoleport accessory kit with the necessary cabling and adapters is provided for making your terminalconnection.

    LINK Green The port is operational.

    Orange The link has been disabled by software.

    Flashing Orange The link is bad and has been disabled due to a hardware failure.

    Off No signal is detected.

    Table 1 LED Descriptions (continued)

    LED State Description

    1-9 10-19 20-29 30-39 40-49 50-59 60-69 70-79 80-89 90-100

    SwitchLoad

    Load % 1 2 8 1 5

  • 8/6/2019 Catalyst 5505

    5/18

    Catalyst 5000 Series Supervisor Engine III G Installation and Configuration Note 5

    Console Port Mode Switch

    Console Port Mode SwitchThe console port mode switch allows you to connect a terminal to the supervisor engine using thedesired console cable.

    Note The cable and adapters shipped with the switch are the same ones used on the Cisco 2500series routers (and other Cisco products).

    You can also connect a modem to the console port using the cable and adapter provided withthe switch.

    Use the console port mode switch as follows:

    Mode 1Switch in the in position. Use this mode to connect a terminal to the console port usingthe console cable and data terminal equipment (DTE) adapter (labeled Terminal) that shippedwith the supervisor engine.

    You can also use this mode to connect a modem to the console port using the console cable anddata communications equipment (DCE) adapter (labeled Modem) that shipped with the switch.

    Mode 2Switch in the out position. Use this mode to connect a terminal to the console portusing the Supervisor Engine III console cable (not provided).

    For more information on using the console port, refer to the Catalyst 5000 Series Supervisor Engine Installation Guide .

    MemoryOnboard memory consists of dynamic random-access memory (DRAM) for the default systemsoftware, Flash memory for downloading and storage of the system software, and nonvolatile RAM(NVRAM) for the conguration le. Refer to the release notes for your Catalyst 5000 series

    supervisor engine software release for the minimum requirements.

    Flash MemoryFlash memory allows you to load and store system software images. Supervisor Engine III G has8 MB of Flash memory. You can download a new software image over the network or from a localTrivial File Transfer Protocol (TFTP) server.

    EEPROMAn electronically erasable programmable ROM (EEPROM) component on the supervisor enginestores module-specic information, such as the module serial number, part number, controller type,hardware revision, conguration information, and other details unique to each module. Thesupervisor engine EEPROM also contains an address allocator, which is a bank of 1024 hardware ormedia access control (MAC)-level addresses, one for each possible VLAN in the system.

    NVRAMThe conguration le is stored in nonvolatile random-access memory (NVRAM).

  • 8/6/2019 Catalyst 5505

    6/18

    6 Catalyst 5000 Series Supervisor Engine III G Installation and Conguration Note

    Safety Recommendations

    Safety RecommendationsSafety warnings appear throughout this note in procedures that, if performed incorrectly, may harmyou. A warning symbol precedes each warning statement.

    Warning This warning symbol means danger . You are in a situation that could cause bodily injury.Before you work on any equipment, be aware of the hazards involved with electrical circuitry andbe familiar with standard practices for preventing accidents. To see translations of the warnings thatappear in this publication, refer to the appendix Translated Safety Warnings in the Catalyst 5000Series Supervisor Engine Installation Guide .

    Ensuring SafetyThis section covers the following topics:

    Following Basic Electrical Safety Guidelines, page 6 Preventing ESD Damage, page 7Use the following guidelines to ensure your safety and protect the equipment. This list does notinclude all potentially hazardous situations during installation, so be alert .

    Note Power supplies in the Catalyst 5002 switch do not have on/off switches.

    Warning Only trained and qualied personnel should install, replace, or service this equipment.

    Always turn all power supplies off (the position marked zero), and unplug all power cords beforeinstalling or removing a chassis.

    Keep the chassis area clear and free of dust during and after installation.

    Keep tools and chassis components off the oor and away from foot trafc. Avoid wearing jewelry and securely fasten any loose clothing that could get caught in the chassis.

    Warning Beforeworking on equipment that is connected to power lines, remove jewelry (includingrings, necklaces, and watches). Metal objects will heat up when connected to power and ground andcan cause serious burns or weld the metal object to the terminals.

    Warning Ultimate disposal of this product should be handled according to all national lawsand regulations.

    Following Basic Electrical Safety GuidelinesWhen working with electrical equipment, exercise these basic safety guidelines:

    Never install equipment that appears to be damaged. Locate the emergency power-off switch for the room in which you are working before beginning

    any procedures that require access to the chassis interior.

    Disconnect all power and external cables before installing or removing a chassis. Do not work alone when potentially hazardous conditions exist.

  • 8/6/2019 Catalyst 5505

    7/18

    Catalyst 5000 Series Supervisor Engine III G Installation and Configuration Note 7

    Removing and Replacing the Supervisor Engine

    Never assume that power has been disconnected from a circuit; always check. Do not perform any action that creates a potential hazard to people or makes the equipment

    unsafe.

    Examine your work area carefully for possible hazards such as moist oors, ungrounded powerextension cables, and missing safety grounds.

    Warning Do not work on the system or connect or disconnect cables during periods of lightning activity.

    Preventing ESD DamageESD damage occurs when electronic modules or components are improperly handled and can resultin complete or intermittent failures. To prevent ESD damage, follow these guidelines:

    Always use an ESD-preventive wrist or ankle strap and ensure that it makes good skin contact. When handling modules or coming into contact with any internal components, always use a wrist

    strap connected to one of the following: Captive installation screws on an installed module or power supply

    ESD wrist strap connector

    Any unpainted surface on the chassis

    Handle modules by the edges only. Avoid contact between the modules and clothing. The wrist strap protects only the module from

    ESD voltages on the body; ESD voltages on clothing can still cause damage.

    After removing a supervisor engine, place it on an antistatic surface or in a static-shielding bag.If you plan to return the module to the factory, immediately place it in a static-shielding bag.

    Caution Periodically check the resistance value of the antistatic strap. The measurement should bebetween 1 and 10 megohms (Mohms).

    Removing and Replacing the Supervisor Engine

    Note To support supervisor engine redundant operation, both the supervisor engines must beSupervisor Engine III Gs.

    Note Catalyst 5505, Catalyst 5509, and Catalyst 5500 switches When two supervisor enginesare installed, hot swapping allows you to remove and replace one of the supervisor engines withoutturning off the system power.

    Avoiding Problems When Inserting and Removing ModulesThe ejector levers on the supervisor engine align and seat the supervisor engine connectors in thebackplane. (See Figure 3 .) If you fail to use the ejector levers to insert the supervisor engine, you candisrupt the order in which the pins make contact with the backplane. When removing a supervisor

  • 8/6/2019 Catalyst 5505

    8/18

    8 Catalyst 5000 Series Supervisor Engine III G Installation and Conguration Note

    Removing and Replacing the Supervisor Engine

    engine, use the ejector levers to ensure that the supervisor engine connector pins disconnect from thebackplane properly. Any supervisor engine or switching supervisor engine that is only partiallyconnected to the backplane can disrupt the system.

    Figure 3 Ejector Levers and Captive Instal lation Screws

    Removing the Supervisor EngineBefore you remove a supervisor engine, you should rst upload the current conguration to a server.This saves time when bringing the supervisor engine back online. Enter the write networkcommand to upload the conguration le to the network. Enter the copy command to download thecurrent conguration to a Flash memory device on the new supervisor engine.

    To remove the supervisor engine from the switch, follow these steps:

    Caution To prevent ESD damage, handle switching modules by the carrier edges only.

    Caution When removing or inserting a switching module, always wear an ESD wrist strapconnected to the Catalyst 5000 series switch ESD wrist strap connector.

    Step 1 Take the necessary precautions to prevent ESD damage, as described in the PreventingESD Damage section on page 7.

    Step 2 If you do not plan to immediately reinstall the supervisor engine you are removing,disconnect any network interface cables attached to the module ports.

    Step 3 Use a screwdriver to loosen the captive installation screws at the left and right sides of themodule.

    Step 4 Grasp the left and right ejector levers. Simultaneously pull the left lever to the left and theright lever to the right to release the module from the backplane connector.

    Step 5 Grasp the handle of the module with one hand and place your other hand under the carrierto support and guide the module out of the slot. Avoid touching the module itself.

    Step 6 Carefully pull the module straight out of the slot, keeping your other hand under thecarrier to guide it. Keep the module at a 90-degree orientation to the backplane.

    Step 7 Place the removed supervisor engine on an antistatic mat, foam, or bag.

    2 4 2 2 2

    S Y S T

    E M

    S T A T

    U S 1 0 0 %

    R E S E

    T F A

    N S W I T C

    H

    L O A D

    1 %

    A C T I V

    E

    P S 1

    P S 2

    SUPERVISOR ENGINE III G-SERIES

    WS-X5550

    LINK

    PORT 1 PORT 2

    LINK

    CONSOLE

    CONSOLEPORTMODE

    RSFC CONSOLE

    Captiveinstallationscrews

    Ejector lever

  • 8/6/2019 Catalyst 5505

    9/18

    Catalyst 5000 Series Supervisor Engine III G Installation and Configuration Note 9

    Installing the Supervisor Engine

    Step 8 If the slot is to remain empty, install a module ller plate to keep dust out of the chassisand to maintain proper airow through the module compartment.

    Caution Always install a switching module ller plate in empty switching module slots to maintain theproper ow of cooling air across the modules.

    Note When you remove and replace the supervisor engine, the system provides status messages ontheconsole screen. The messages are for information only. Enter the show system and showmodulecommands to view specic information. Foradditional information, refer to the Catalyst 5000 SeriesSoftware Conguration Guide and the Catalyst 5000 Series Command Reference publication.

    Installing the Supervisor EngineWhen installing the supervisor engine, note that it must go in a specic slot:

    Catalyst 5000slot 1 Catalyst 5505, 5509, and Catalyst 5500slot 1 (if a second, redundant supervisor is installed, it

    goes in slot 2)

    Catalyst 5002slot 1To install the supervisor engine, follow these steps:

    Caution To prevent ESD damage, handle switching modules by the carrier edges only.

    Caution When removing or inserting a switching module, always wear an ESD wrist strapconnected to the Catalyst 5000 series switch ESD wrist strap connector.

    Step 1 Take the necessary precautions to prevent ESD damage, as described in the PreventingESD Damage section on page 7.

    Step 2 To install the supervisor engine, hold the front panel with one hand, and place your otherhand under the carrier to support the supervisor engine. Do not touch the printed circuitboards or connector pins.

    Step 3 Align the edges of the supervisor engine carrier with the slot guides on the sides of theswitch chassis.

    Step 4 Pivot the two module ejector levers out away from the faceplate. The ejector levers areshown pivoted out in Figure 4 .

  • 8/6/2019 Catalyst 5505

    10/18

    10 Catalyst 5000 Series Supervisor Engine III G Installation and Conguration Note

    Connecting a Terminal to the Console Port

    Figure 4 Module Ejector Lever Operation

    Step 5 Keeping one hand under the carrier to guide the supervisor engine, carefully slide it intothe slot on the Catalyst 5000 series switch until the ejector levers click into place on thechassis. Be sure to keep the module horizontal to the backplane and avoid touching anyof the components on the module.

    Step 6 Using the thumb and forenger of each hand, simultaneously pivot in both ejector levers,as shown in Figure 4 , to fully seat the switching module in the backplane connector.

    Caution Always use the ejector levers when installing or removing switching modules. A modulethat is partially seated in the backplane will cause the system to halt and subsequently crash.

    Step 7 Use a screwdriver to tighten the captive installation screws at the left and right sides of the module.

    Connecting a Terminal to the Console PortConnect the terminal using a thin, at, RJ-45-to-RJ-45 cable (looks like a telephone cable) and anRJ-45-to-DB-9, RJ-45-to-D-subminiature female, or RJ-45-to-D-subminiature male adapter.

    Note An RJ-45-to-RJ-45 cable and adapters are provided in the console port accessory kit shippedwith your Supervisor Engine III.

    See the next section, Conguring a Terminal for Attachment to the Console Port, for portconguration details. Table 2 lists the pinouts for the console port.

    2 4 2 5 2

    S Y S T

    E M

    S T A T

    U S 1 0 0 %

    R E S E

    T F A

    N S W I T C

    H

    L O A D

    1 %

    A C T I V

    E

    P S 1

    P S 2

    SUPERVISOR ENGINE IIIG-SERIES

    WS-X5550

    LINK

    PORT 1 PORT 2

    LINK

    CONSOLE

    CONSOLEPORTMODE

    RSFC CONSOLE

    Ejector lever

    Captiveinstallationscrew

  • 8/6/2019 Catalyst 5505

    11/18

    Catalyst 5000 Series Supervisor Engine III G Installation and Configuration Note 11

    Configuring a Terminal for Attachment to the Console Port

    Table 3 lists the pinouts for the RSFC console port.

    Conguring a Terminal for Attachment to the Console Port

    Note The console port is an asynchronous serial port; any device connected to this port must becapable of asynchronous transmission.

    Before connecting the console port, check the terminal documentation to determine the baud rate.The baud rate of the terminal must match the default baud rate (9600 baud) of the console port. Setup the terminal as follows:

    9600 baud 8 data bits No parity 1 stop bit

    Table 2 Console Port Pinouts

    Console Port Console Device

    Pin (signal) Connect to

    1 is looped to pin 8

    2 (DTR) DSR

    3 (RxD) TxD

    4 (GND) GND

    5 (GND) GND

    6 (TxD) RxD

    7 (DSR) DTR

    8 is looped to pin 1

    Table 3 RSFC Console Port Pinouts

    Console Port Console Device

    Pin (signal) Connect to

    9 is looped to pin 16

    10 DTR (out)

    11 TxD or RxD

    12 (GND)

    13 (GND)

    14 RxD or TxD

    15 RTS (in)

    16 is looped to pin 9

  • 8/6/2019 Catalyst 5505

    12/18

    12 Catalyst 5000 Series Supervisor Engine III G Installation and Conguration Note

    Connecting to the Interface Ports

    Connecting to the Interface PortsThe Supervisor Engine III G has two GBICs with 1000BaseSX MMF connectors, 1000BaseLX/LHMMF and SMF connectors, or 1000BaseZX connectors (see Figure 5 ).

    The 1000BaseSX MMF, 1000Base LX/LH MMF and SMF, and 1000BaseZX ports operate infull-duplex mode only.

    For information on interface cables and equipment, such as Ethernet transceivers, refer to theCatalyst 5000 Series Supervisor Engine Installation Guide .

    1000BaseSX, 1000BaseLX/LH, and 1000BaseZX (Single-Mode or MultimodeFiber-Optic Connectors)

    Use SC ber-optic connectors (see Figure 5 ) to connect to the 1000BaseSX, 1000BaseLX/LH, and1000BaseZX ports. Always keep caps and plugs on the ber-optic connectors on the cable and theswitch when they are not in use.

    Warning Because invisible laser radiation may be emitted from the aperture of the port when nocable is connected, avoid exposure to laser radiation and do not stare into open apertures.

    Figure 5 SC Fiber-Optic Connector Type

    Connecting Gigabit Ethernet ModulesSupervisor Engine III G has Gigabit Ethernet ports that you can congure with any combination of

    GBICs. A GBIC, shown in Figure 6 , is a hot-swappable input/output device that plugs into themodule, linking the module with the ber-optic network. GBIC types are listed in Table 4 .

    Cable

    Plug

    Receptacle

    Keys

    R e c e

    i v e r

    T r a n s

    m i t t e

    r

    Light outof fiber

    Light intofiber

    1 3 0 8 7

    Key slots

  • 8/6/2019 Catalyst 5505

    13/18

    Catalyst 5000 Series Supervisor Engine III G Installation and Configuration Note 13

    Connecting Gigabit Ethernet Modules

    Figure 6 GBIC

    Note Cisco 1000BaseLX/LH interfaces fully comply with the IEEE 802.3z 1000BaseLX standard.However, the 1000BaseLX/LH has a higher optical quality, allowing link distances of 10 km overSMF versus the 5 km specied in the standard.

    Note A maximum of 12 1000BaseZX GBICs can be installed in a switch chassis.

    The GBIC slides through an opening in the front of the Gigabit Ethernet module and mates with aconnector on the module. (See Figure 7 .)

    Figure 7 Installing a GBIC (WS-X5403 shown)

    Use a SC-type single-mode (ber) connector, shown in Figure 5 , to connect the Gigabit Ethernetmodule ports with the external network. Connect the Gigabit Ethernet interface cables to theappropriate Ethernet network connector.

    When using the LX/LH GBIC with 62.5-micron diameter MMF, you must install amode-conditioning patch cord (Cisco product number CAB-GELX-625 or equivalent) between theGBIC and the MMF cable on both the transmit and receive ends of the link. The patch cord isrequired for link distances greater than 984 feet (300 m). Refer to the Catalyst 5000 SeriesSupervisor Engine Installation Guide for more information on patch cords.

    Table 4 GBIC Types

    GBIC Product Number

    1000BaseSX WS-G5484

    1000BaseLX/LH WS-G5486

    1000BaseZX WS-G5487

    1 1 8 2 5

    Receiver Transmitter

    1 8 3 5 7

    Plug

    S Y S T

    E M

    S T A T

    U S 1 0 0 %

    R E S E

    T F A N

    S W I T C

    H

    L O A D

    1 %

    P S 1

    P S 2

    S UP E R VIS O R E NG INE III G -S E R IE S

    W S-X 55 5 0

    LINK

    PORT1

    PORT2

    LINKC O NS OLE

    C ON S O LEPO R T MO DE

    R S F C C O NS O LE

  • 8/6/2019 Catalyst 5505

    14/18

    14 Catalyst 5000 Series Supervisor Engine III G Installation and Conguration Note

    Verifying System Operation

    Note The mode-conditioning patch cord is required to comply with IEEE standards. The IEEEfound that link distances could not be met with certain types of ber-optic cable due to a problem inthe center of some ber-optic cable cores. The solution is to launch light from the laser at a preciseoffset from the center by using the mode-conditioning patch cord. At the output of the patch cord,

    the LX/LH GBIC is compliant with IEEE 802.3z standard for 1000BaseLX.

    Verifying System OperationWhen all interfaces are connected, check all connections, and then follow these steps to verify thatthe switch is operational:

    Step 1 Check the console terminal and make sure it is on.

    Step 2 Verify that the appropriate PS1 and PS2 LEDs on the supervisor engine front panel aregreen.

    Step 3 While the system initializes, check that the SYSTEM STATUS LED on the supervisor

    engine is orange until the boot is complete.Step 4 Some interface LEDs might go on or blink for a short time. Some LEDs, such as the Link

    LED, stay on during the entire boot process. If an interface is already congured, theLEDs might be on steadily as they detect trafc on the line. Wait until the system boot iscomplete before attempting to verify the switching module LED indications.

    Note Catalyst 5505, Catalyst 5509, and Catalyst 5500 If you have a redundantsupervisor engine, refer to the Catalyst 5000 Series Installation Guide for a detaileddescription of supervisor engine operation in a redundant conguration. By default, thesupervisor engine in slot 1 is the active supervisor; the second supervisor in slot 2 is thestandby supervisor.

    Note Many of the switching module LEDs are not on until you congure the interfaces.

    Step 5 When the system boot is complete (it takes a few seconds), the supervisor engine beginsto initialize the switching modules.

    During this initialization, the LEDs on each switching module behave differently (mostash on and off). The Status LED on each switching module goes on when initializationis complete, and the console screen displays a script and system banner.

    Note When switching module LEDs are on, this does not necessarily mean that theinterface ports are functional or enabled. Although the LEDs for many interface types goon at the initial system startup, they do not indicate an accurate status until the interfaceis congured. For detailed module-specic LED descriptions, refer to the Catalyst 5000Series Module Installation Guide .

  • 8/6/2019 Catalyst 5505

    15/18

  • 8/6/2019 Catalyst 5505

    16/18

  • 8/6/2019 Catalyst 5505

    17/18

  • 8/6/2019 Catalyst 5505

    18/18