Catalogue 2004 - Micronix Plus | Termoviziune - Aparate ... · PDF fileCatalogue 2004. SPECIAL...
Transcript of Catalogue 2004 - Micronix Plus | Termoviziune - Aparate ... · PDF fileCatalogue 2004. SPECIAL...
SPECIAL SCALING RANGE CODE
Range
1V
1B
1T
2A
2B
2T
Input Display
0 to (100 to 1999) one point fixed
0 to (100 to 1999) one point fixed
±1999 to ±1999 one point fixed
0 to (100 to 1999) one point fixed
0 to (100 to 1999) one point fixed
±1999 to ±1999 one point fixed
1 to 5V
Voltage (from 0V)
Voltage
4 to 20mA
Current (from 0mA)
Current
*1V, 2A Except process monitor 1V and 2A*Need additional cost for the above ranges
URL http://www.asahikeiki. co. jpE-mail:dpm-overseas@asahikeiki. co. jp
COMPANY PROFILE
ASAHI KEIKI CO.,LTD. was established in 1950 as amanufactuer of industrial measuring instruments.We have since expanded into digital panel meters,intelligent meters and bimetallic thermostats.Rapid changes in electronic technoligy keeps us atthe forefront of these product areas.We constantly strive to meet customer's demands forerver higher quality and reliability.
ASAHI KEIKI CO.,LTD. Head Office :33-6, YAGUCHI 2-CHOME,
OHTA-KU,TOKYO 146-8505, JAPAN Telephone :(03)3759-3893 Fax :(03)3757-2989 Establishment :Sept, 1950 Capital :¥ 50,000,000.–
1
DC Voltmeter and Ammeters
Setpoint Comparator
AP-101 13page1/8 DIN Size
Low Cost
A5000 15page AP-141 16page1/8 DIN Size
Low Cost
AP-201A 19page 1/32 DIN Size
Low Cost
AP-244A21page1/32 DIN Size
BCD output
AP-30125pageThin case
Low Cost
AP-501A 26page 1/8 DIN Size
Thin case, Low cost
AP-520A 28page1/8 DIN Size
LCD, Low cost
AP-200 18page1/32 DIN Size
AH-331 31pageopen case
AM-147 37page1/8 DIN Size
RS-232C
AM-215 35page 1/32 DIN Size Two setpoint
A5000 49page
AMH-762 44page1/8 DIN Size
High Conversion
2
AP-166 47page1/8 DIN Size
Average
A5000 49page
AC Voltmeter and Ammeters
A5000 59page
Strain Gauge
AS-203A 51page1/32 DIN Size
Low cost
AL-501A 53page1/8 DIN Size
LCD, Two-wire
AL-512 55page1/8 DIN Size
LED, Two-wire
AT-205 58page1/32 DIN Size
TC, RTD
Thermo Meter
Process Monitor
A5000 57page
A7000 series 61page
NEWUniversal Type
AP-560 48page1/8 DIN Size
A6000 series 64page
NEW
ASG-251 60page1/32 DIN Size
A5000 17page
3
TZ-5A 87pageRTD
TH-1X 79pageslim size
TZ-41 86pageSelf power
TW-2X 75page2 output
TZ-5H 84pageDC V,A
TW-3M 74pageProgramable
Transmitter
TZ-1D 71pageAC Power SupplyCT
TZ-1B 70pageAC Power SupplyPotentiometer
TZ-1X 69pageAC Power SupplyDC V,A
NEW NEW NEW
TZ-1F 73pageAC Power SupplyDC V,A (Small)
TZ-1E 72pageAC Power SupplyPT
NEW NEW
4
TABLE OF CONTENTTable of Contents..................................................................................................................4,5Explanation..........................................................................................................................6~8Applications ......................................................................................................................9~11Application Examples ............................................................................................................12
DC Voltmeter & Ammeter
AP-101 3 1/2 Digit V,A ............................................................................................13AP-102 3 1/2 Digit V,A, BCD ..................................................................................14
A5000 4 Digit V, A ................................................................................................15AP-141 4 1/2 Digit V ..............................................................................................16AP-142 4 1/2 Digit V, BCD ......................................................................................17AP-200 3 1/2 Digit V, 1/32 DIN ..............................................................................18AP-201A 3 1/2 Digit V, 1/32 DIN ..............................................................................19AP-202A 3 1/2 Digit V,A, 1/32 DIN, BCD ..................................................................20AP-244A 4 1/2 Digit V, 1/32 DIN, BCD......................................................................21AP-301 3 1/2 Digit V, Thin case ..............................................................................25AP-501A 3 1/2 Digit V, Thin case ..............................................................................26AP-502 3 1/2 Digit V, A ..........................................................................................27AP-520A 3 1/2 Digit V, LCD ......................................................................................28AP-540 3 1/2 Digit V,A ............................................................................................29AH-330, 331 3 1/2 Digit V, open case ............................................................................31AH-381 3 1/2 Digit V, LCD, open case ..................................................................32
A7000 series ..........................................................................................................................61 A6000 series ..........................................................................................................................64
Comparator (Meter Relay)
AM-123 4 Digit, Two setpoint ..................................................................................33AM-213 4 Digit, Two setpoint ..................................................................................34AM-215 4 Digit, 1/32 DIN, Two setpoint ............................................................35,36AM-147 4 Digit, RS-232C ..................................................................................37,38AM-749 4 1/2 Digit, Four setpoint, RS-485, RS-232C ........................................39,40AMH-752 3 1/2 Digit, High Conversion rate (4000/sec) ......................................41~43AMH-762 4 Digit, High Conversion rate (4000/sec) ............................................44~46
A7000 series ..........................................................................................................................61 A6000 series ..........................................................................................................................64
AC Voltmeter & Ammeter
AP-166 4 Digit, Average ........................................................................................47AP-560 3 Digit, Line Monitor ..................................................................................48
A5000 4 Digit, TRUE-RMS ....................................................................................49 A7000 series ..........................................................................................................................61 A6000 series ..........................................................................................................................64
Process Monitor (1 to 5V, 4-20mA, etc)
AS-101 3 1/2 Digit, A,V ..........................................................................................50AS-203A 3 1/2 Digit, A,V 1/32 DIN ............................................................................51AS-201 3 1/2 Digit, V 1/32 DIN ..............................................................................52AL-501A 3 1/2 Digit, A, Two-wire, LCD ....................................................................53AL-213 3 1/2 Digit, A, Two-wire, LED, 1/32 DIN ....................................................54AL-512 3 1/2 Digit, A, Two-wire, LED ....................................................................55AS-243 4 Digit, A,V ................................................................................................56
A7000 series ..........................................................................................................................61 A6000 series ..........................................................................................................................64
5
Thermometer
A5000 Sensor K,J,T,S,B,R,PT-100Ω......................................................................57AT-205 Sensor K,J,PT-100Ω, 1/32 DIN ..................................................................58
A7000 series ..........................................................................................................................61 A6000 series ..........................................................................................................................64
Strain Gauge Meter
A5000 4 Digit ........................................................................................................59ASG-251 3 1/2 Digit 1/32 DIN ..................................................................................60
A7000 series....................................................................................................................61~63 A6000 series ..........................................................................................................................64
Transmitter
TZ-1X DC V,A AC Power Supply ..........................................................................69 TZ-1B Potentiometer AC Power Supply................................................................70 TZ-1D CT AC Power Supply ................................................................................71 TZ-1E PT AC Power Supply..................................................................................72 TZ-1F DC V,A (Small) AC Power Supply ..............................................................73
TW-3M DC V,A ......................................................................................................74TW-2X DC V,A (2 output) ......................................................................................75TW-2XA DC V,A (2 output) AC Power Supply..........................................................76TW-2C TC, RTD......................................................................................................77TW-3R Alarm setter ................................................................................................78TH-1X DC V,A ......................................................................................................79TH-1C TC, RTD......................................................................................................80TH-41 Two-wire (2ch) ..........................................................................................81TH-1M DC V,A ......................................................................................................82TZ-5L Distributor ..................................................................................................83TZ-5H DC V,A ......................................................................................................84TZ-5X DC V,A ......................................................................................................85TZ-41 Two-wire ....................................................................................................86TZ-5A RTD ..........................................................................................................87TZ-5B Potentiometer ............................................................................................88TZ-5C TC ..............................................................................................................89TZ-5D AC, A..........................................................................................................90TZ-5E AC, V ..........................................................................................................91TZ-5F DC, A,V ......................................................................................................92
Accessories ..............................................................................................................93,94
New Model
ASAHI KEIKI CO.,LTD.6
OUTLINE
Digital panel meters are commonly used for various displays in awide range of equipment and analog-to-digital conversion in highlyadvanced control systems due to recent progress in highly accuratedigital measurement.
Digital panel meters (DPMs) have wide applications and come invarious types suitable to many application specifications, and differfrom digital multi-meters (D.M.M) in that they are used especially forsingle function, single range measurement.
Recently, a digital meter relay consisting of a digital panel meterwith a comparison function using digital switches has beendeveloped, thereby enabling not only the reading of normal values,but also the comparison of large, medium and small values.
Recent progress in electronics, especially in transistor technologyhas been remarkable, and the progressive development of ICs, LSIsand ultra LSIs, has greatly facilitated the transmission of informationand the emergence of a highly advanced information society.
The small size and low cost of DPMs is a result of innovations insemiconductor technology and has led to the widespreadreplacement of analog indicators as part of industry's move toautomate equipment and reduce labor costs.
DPMs provide a high level of measurement accuracy impossiblewith analog instruments and have an added advantage in that theycan be accurately and unambiguously read at a glance. In addition,DPMs have a system output function which converts analog signalsfrom sensors to digital signals for direct input to equipment such ascomputers, recorders and computing units to facilitate recording andautomatic control.
Asahi Keiki can provide a number of digital panel meters to meet awide range of applications through reliable design and quality controlbased on long experience with digital techniques. This is supportedby extensive and rigorous past production testing which is part of ourquality-assurance control system using standards that are directlytraceable to National standards. This quality assurance system isbacked by an equally extensive and experienced after sales service.
METER SELECTION
1. Applications1) For display only
For reading of general instruments2) For control of systems provided with system BCD input.
2. Measured signals1) Voltage/current2) DC/AC
3. No. of display digitsCurrently, 3 1/2 (1999), 4 (9999) and 4 1/2 (19999) digits areavailable. Resolution defined in terms of what division in % of fullscale is necessary to be read.For example, the resolution of a DPM displaying 1.999V is 1mV.
4. Measuring rangeThis ranges from µV minimum to V maximum as required. For example, if the number of digits and the voltage valuecorresponding to the least significant digit such as ±199.9mV or±1.9999V are determined, the measuring range is also determined.
5. AccuracyThe maximum error guaranteed by the manufacturer is calledaccracy. For example, ±0.15% rdg. ±1 digit for 3 1/2 digits or±0.03% rdg ±1 digit for 4 1/2 digits. The latter means that the errorof thedisplayedvalue 19999 is within ±7 digits and that of thedisplayed value 10000 is within ±4 digits.
6. Measuring SpeedThe speed required depends on the measured object and may notbe very important when the DPM is used only for display. However,an increase in speed in the entire measuring system results inimproved efficiency and labor savings, and it should be noted thatan increase in measuring speed reduces the time needed tointegrate (averaging) the input signal to bring about signal changeand fluctuated display with the signal change. Therefore, it isnecessary to select speed in accordance with applications.
7. Power Supply1) AC 90 to 132V and 180 to 264V selectable, 50/60Hz2) DC 5V ±5%, Mostly uses stabilized power3) DC 24V ±10% or 20%4) DC 12V ±10%
8. Input type1) Floating input
Input terminals are all isolated from the external case, powersupply and output circuit as is most desirable for systemapplications.Photo-couplers, pulse transformers and relays are used asisolators. In addition, this type can have a large common moderejection ratio (CMR). The AC power drive display only andsystem application DPM (with parallel BCD output) belongs tothis type.
2) Non-floating input2-1 Input with isolated common point
One input terminal is connected to one output terminal, but,it is isolated from the external case and power supply.
2-2 Input with common point and one power supply terminalOne input terminal is connected to one power supplyterminal.The DC 5V driven display-only DPM belongs to this type.From the above different standpoints, the following types areavailable.1) Single ended input2) Differential inputThe former has 2 terminals, Hi and Lo, but the latter canmeasure the signal between 2 input terminals regardless ofthe voltage applied to each input terminal and the commonpoint, which is similar to a differential OP amplifier.Therefore, this type completely differs from the floating inputtype in that measurement is impossible if the common pointis not used, being of the 3-terminal type. This type haslarge CMR to further increase the common mode rejectioneffect.
9. Input impedance and bias currentDPM input impedance is usually more than 100Mス, (excludingDPMs with an attenuator for an input range of more thanア 2V),but this is the ratio between input voltage change and input currentchange.Current close to the constant current, called bias current, also flowsthrough the input circuit and therefore, if there is high resistance inthe signal source, a voltage drop is produced across the resistancewhich is added to measured voltage as an error. Therefore,attention should be paid to the bias current according to the circuitused.
DIGITAL PANEL METEREXPLANATION
ASAHI KEIKI CO.,LTD. 7
CAUTIONS
1. Prior to operating the digital panel meter, carefully read the
instruction Manual.
2. Environment where the meter is used.1) It is desirable that meter be used under the normal room
temperature from 0 to 50。C and relative humidity of 80% or less.The temperature is the most important factor exerting aninfluence upon meter reliability. Therefore, use the meter underthe normal room temperature as much as possible. Absolutelyavoid dew condensation caused by rapid temperature change.
2) Pay attention to not applying vibration and shock to the meter.3) Use the meter where no dust, chemicals and gases harmful to its
electronic components exist.
3. Storage
For long storage, avoid direct rays of the sun and store in atemperature from -10 to +70°C and relative humidity of 60% or less. Itis desirable that the meter be packaged in the same manner as thatdone prior to shipment.
4. Noise1) Power supply circuit
The digital panel meter driven by AC power may be influencedby electric noise entering through the power line. A capacitorfor noise prevention is inserted between the line on the primaryside of a power transformer.However, it is actually impossible to build a perfect noiseprevention circuit in such a small device as a DPM. Therefore, ifpower relays, magnet switches and/or high frequency devicesare connected to the same power line and/or abnormal voltagecaused by lightning etc., may be generated in the line, externallyconnect a line filter, varistor or noise absorption circuit.
2) ShieldThe circuit in the digital meter is protected from electrostaticinduction by the employment of a shielded case andelectrostatic shielded terminals of the power transformer.Therefore, if any problem occurs due to noise, connect thecommon terminal E to the ground or equipment groundingterminal.If any problem caused buy space induction may occur, groundthe metal case. For a molded case, is it effective when it iscovered with a metal case which most be grounded.
5. Handling of measuring input lineThe input impedance of the digital meter is very high in value of
1Mス to 100Mス so that the meter may influenced by induction noisedepending on its surroundings.1) Use a shielded 2-Conductor wire for the input line.2) Connect a RC filter in the input line.
However, pay attention that response time may become longerdepending on RC time constants.
6. Handling of system output line1) Bundling of wires
In general, the data output from the digital meter is a T.T.L ICwith latch, and no consideration for real data transmission is paidat all.Since it has the signal source impedance of several K%Ω, Theproximity of large current power line, relay and magnet switchcircuits to the output line may cause a malfunction due toelectromagnetic induction caused by electrostatic induction andmagnetic field induced by surge voltage and/or current pulses.may shorten meter life. Therefore, the output wires should be
bundled independent form other wires and to be wired apartfrom the power line as much as possible.
2) Length of transmission lineThe length of transmission line may have to be changeddepending on noise around the meter and surroundings.2-1 Direct transmission of output line: 2 m or less2-2 Transmission when a buffer circuit is used for each bit of
output line: 50 m or less2-3 Transmission when an isolator such as a photocoupler or
mercury relay is used for each bit of output line: 500 m or less
Caution: The above lengths are only for your reference. Therefore, the actual length must be determineddepending on each application.
DIGITAL PANEL METEREXPLANATION
ASAHI KEIKI CO.,LTD.8
1. High DC voltage measurementWhen voltage exceeding the maximum voltage in the standardrange is measured (for example: more than 200 V), a multiplier isconnected externally.
2. High AC voltage measurementWhen voltage exceeding the maximum voltage in the standardrange is measured (for example: more than 200 V), a multiplier orpotential transformer (PT) is connected externally.
* For the multiplier: Same as 1. High DC voltage measurement.
3. Large DC current measurementWhen large DC current exceeding 2A is measured, a shunt isconnected externally.
4. Large AC current measurementWhen AC current exceeding 0.4 A to 2 A is measured, a currenttransformer (CT) is connected externally.
5. Combination with printerWhen the BCD output of the digital panel meter is printed out andrecorded using digital printer.
6. Combination with recorderWhen the analog output of the digital meter is recorded using arecorder (pen writing recorder).
7. Combination with BCD display unitWhen the BCD output of the digital panel meter is connected to aBCD display unit for remote display.
8. Combination with converter
When each sensor output is connected to a converterwhich converts the output to 4 to 20 mA, 1 to 5 V or
any other voltage or current and also appropriatescaling is made to the digital panel meter, the meterwidens its applications to thermometer, pressuremeter, tachometer, etc. In addition, input isolationand level conversion are enabled when the digitalpanel meter is combined with an isolated converter.
DIGITAL PANEL METEREXPLANATION
ASAHI KEIKI CO.,LTD.
APPLICATIONS
9
Measuring mixing volumes of materials in tanks.
The ASG-157 series digital panel meter supplies power to load cells, subtracts tare weight and also has a built-in output circuit, thereby enabling the measurement of weight at low-cost.The ASG-157 together with load cells helps you make an appropriate mixed liquid by measuring the weight of each of two different chemicals.
Detecting warping of printed circuit boards.
Using the 2-input (A and B channels) computing function.The AMH-762 series digital panel meter applies analog signals from laser displacement sensors installed above two points on the board to its A and B channels, thereby detecting a warp of the board by computing (A-B).
Measuring and evaluating press fitting of parts used for precision machinery.
The peak hold function of the A5000 is used to check and then evaluate parts which are press-fitted to cylinder blocks, etc.
Helping you control rolling.
Our digital panel meters can help you control the rolling process by, measuring the number of roller revolution and also the moving distance of a specific roller in the vertical direction.The AC-963A displays the number of roller revolutions and outputs alarm signals together with a rotary encoder coupled to the shaft of that roller. In addition, the AM-123 inputs the output signal of an eddy current sensor to display the moving distance of the roller and also to output acoustic alarm signals as well as visual alarm signals with changes in display colors.
Measuring distortion of round bodies and eccentricity of shaft.
The peak valley hold function of the A5000together with a laser displacement or eddy current sensor is used to measure irregularity of round shaped bodies or bending of shafts.
Detecting, measuring and then evaluating the length of lead wires extending from capacitors.
Using the 2-input (A and B channels) computing function.The AMH-762 applies sensor detection signals to its A and B channels.It helps you inspect the cutting length of lead wires extending from capacitors by using its (A—B) function.It compares, evaluates and then outputs the computation result at a high sampling speed of 1000 times/sec.In addition, it can also obtain the maximum and minimum of any computed value by using its peak hold and valley hold functions.
A5000
A5000
A5000
AM-123
AMH-762
AMH-762
ASAHI KEIKI CO.,LTD.
APPLICATIONS
10
Helping you inspect the condition of riveting, etc.
The AMH-752 can store severd/ satisfactory patterns of riveting by using its pattern select function. It can store eight types of high/high, high, low and low/low set points, hysteresis values and eight types of scaling values by using its pattern select function.As the allowable range can be instantly changed by the front switch or pattern selection from the rear terminal board, the meter can be conveniently used in any line where two or more different riveting materials exist.
Detecting warping of door glass by a differential transformer.
A sensor power supply is built in the meter. The AM-147, AM-749 or AM-213 has a built-in power supply of 12V or 24V DC for an external device. Therefore, it can be easily connected to a warping sensor with a built-in amplifier. It its direct setling function is used, it can easily set HH, HI, Lo and LL values used for evaluating a warp from measures data detected by the sensor.
Evaluation at high speed in high-speed mode.
Evaluating the clearance of piston rings at high speed.The AMH-762 can evaluate measured data at a speed of 4000 times/sec by the successive A/D conversion method. It can be conveniently used in any environment where inspection time is short.
Helping you process foods and control the process.
The front panel of the meter can be washed as the case is in dust proof and waterproof construction.The AT-216, AT-213, AC-221 and AC-281 conform to the IP66 standard.These meters are most suitable for use in an environment where temperature, pressure, weight, etc. Are measured in the HACCP process control.
Outputting digital signals to peripheral equipment.
Used as a converter with the display function which outputs digital signals to its peripheral equipment in BCD or RC 232C. The RS232 or BCD output function can be selected for all meters.It our digital panel meter is used as a converter whose signal is input to sequencers or personal computers, it can display and check actual input parameters, therefore, it is used conveniently for calibration.
Two or more measured values are multi dropped by RS485.
Contributing to saving the number of output wires.There are many digital panel meters with the output of RS485 in the lineup.Up to 30 meters including one host computer (31 in total) can be connected with two signal wires used, the address set to each meter and an RS485 - to - RW232C converter connected. In addition. If the dedicated "DIGIPANE485" software is used, collected data can be tabulated or graphically displayed.
AM-147
A5000
AT-216
AMH-762
AMH-762
A5000A5000 AM-749
RS485 - to - RW232CConverter(Commercially available)
A7000
ASAHI KEIKI CO.,LTD.
APPLICATIONS
11
There meter sizes are selectable for easily accommodating meters in racks.
Din sizes of 96 mm (W) × 48 mm (H), 72mm (W) × 36 mm (H) and 48 mm (W) × 24mm (H)There are three meter sizes available so that any meter size which satisfies its accommodating space is selectable depending on the application.In addition to these three sizes, the cases of the901 series large display and SP-501A this type (35mm deep) digital panel meters are designed in consideration of their mounting environments.
Inspecting the greased condition of precision parts.
Inspecting the presence or absence of grease.The AS-105 has built-in 24V DC power supply, scaling function and analog comparator. It can configure inspection systems at low cost.
A5000
Measuring large current and high voltage.
Our digital panel meter is connected to CT, PT, DC divider or DC shunt. For example, the AP-168 for AC measurement has its standardized CT connection ranges. It inputs a current of 5A on the CT secondary side to enable scaling of any current value on the primary side.
A5000
ASAHI KEIKI CO.,LTD.12
TRANSMITTERAPPLICATION EXAMPLES
1. ISOLATIONTRANSMITTER
2. NON-ISOLATIONTRANSMITTER
3. TEMP.TRANSMITTER
4. CURRENTTRANSMITTER
5. CURRENTTRANSMITTER
6. POWERSUPPLY
7. POTENTIOMETERTRANSMITTER
TZ-1X
TZ-5X
TZ-5C
TZ-5D
TZ-5D
TZ-5L
TZ-5B
ASAHI KEIKI CO.,LTD. 13
DCV
&A
Ordering Code
Dimensions
Connection Diagram
DC Voltage Measurement
Accuracy: ±0.1% rdg. ±1 digit (23°C±5°C)
DC Current Measurement
Accuracy: ±0.2% rdg. ±1 digit (23°C±5°C)±0.3% rdg. ±1 digit only for AP-101-25
SpecificationsInput Configuration: Single EndedInput Bias Current: 50PA (Typ.)Conversion Rate: 2.5/secNormal Mode Rejection: TYP.40dB (50/60Hz)Zero Stability: Automatic Zero AdjustmentDisplay: LED. 14.2mm 3 1/2-digitPolarity: A “-” is displayed automaticallyDecimal Point: Settable to any digit positionOverrange Indication: When input exceeds the maximum display,
1999 flashes.Power Supply: AC90~132V
AC180~264VDC5V±5%, 100mA (Max.)DC24V±20%, 30mA (Max.)
Operating Temperature: 0~50°C, 35 to 85% RHPower Consumption: 1.5VADimensions: 48(H) × 96(W) × 73(D)mm DIN SizeWeight: Approx. 150g (For AC), 85g (For DC)Dielectric Strength: AC type; Between input (Lo) terminal and
earth, DC500VBetween power supply terminal and input terminal, earth, common, case, AC1500V/1 min.
DC type; Between input (Lo) and power supply (0V), DC±500V
Insulation Resistance: DC500V 100MΩ at above terminals
DC VOLTMETER & AMMETERAP-101
MaximumResolution
±199.9µA±1.999mA±19.99mA±199.9mA±1.999A
Model RangeInternal
ResistanceInput
Protection
AP-101-21AP-101-22AP-101-23AP-101-24AP-101-25
1kΩ100Ω10Ω1Ω
0.1Ω
±10mA±50mA
±150mA±500mA
±3A
100nA1µA10µA
100µA1mA
AP-101- -
11
1415 ±800V (Option)
Range
~ 21
25
Power Supply 1. AC90~132V2. AC180~264V3. DC5V (Isolated)4. DC24V (Isolated)
~
48
96
73506.6
92
Min.120
Min
.70
+0.8-0
45+
0.6
-0
Front
Side
Panel cut
1 2 3 4 5 6 7 8 9 10 11 12 1413 1615 17 18
INPUT DC POWERD.P
0V + 101102103LOHI CO
MH
OLD STA
RT
Features
• Low Cost
• Bright LED 14.2mm (Red)
• AC180~264V, 90~132V, DC5V, DC24V
• 200mV~200V, 200µA~2A Measurement
• ±800V Measurement (option)
Standard 3 1/2 Digit
MaximumResolution
±199.9mV±1.999 V±19.99 V±199.9 V
Model RangeInput
ImpedanceInput
Protection
AP-101-11AP-101-12AP-101-13AP-101-14
100MΩ100MΩ10MΩ10MΩ
±250V±250V±250V±500V
100µV1mV
10mV100mV
ASAHI KEIKI CO.,LTD.14
DCV
&A
Ordering Code
Dimensions
Connection Diagram
DC Voltage Measurement
Accuracy: ±0.1% rdg. ±1 digit (23°C±5°C)
DC Current Measurement
Accuracy:±0.2% rdg. ±1 digit(23°C±5°C)±0.3% rdg. ±1 digit only for AP-102-25
SpecificationsInput configuration: Single EndedInput Bias Current: 50PA(Typ.)Conversion Rate: 2.5/sec or 12.5/sec(50Hz), 15/sec(60Hz)Normal Mode Rejection: More than 40dB(50/60Hz)Zero Stability: Automatic Zero AdjustmentDisplay: LED, 14.2mm 3 1/2 -digitPolarity: A”-” is displayed automaticallyDecimal Point: Settable to any digit positionOverrange Indication: When input exceeds the maximum display,
1999 or -1999 flashes.Power Supply: AC90~132V, AC180~264V, DC5V±5%Operating Temperature: 0~50°C, 35 to 85%RHPower Consumption: 1.5VADimensions: 48(H) × 96(W) × 73(D)mm DIN SizeWeight: Approx. 150g(For AC), 85g(For DC)Dielectric Strength: AC type;Between input(Lo)terminal and earth,
DC500VBetween power supply terminal and inputterminal, earth, common, case, AC1500V/ 1 min.DC type;Between input(Lo)and powersupply(0V), DC500V
Insulation Resistance: DC500V 100MΩ at above terminals
BCD Data Output (Isolated from input (Lo))Measured data: Tri-state parallel BCD positive logic latch
outputPolarity signal: “1” level at plus input“OVER” signal: “1” level at overflow inputPrinting command signal: A positive pulse of approx 1ms at every
measurement completionEach signal of the above: TTL level Fanout=2*Each signal of the above can be changed to negative logic
DC VOLTMETER & AMMETERAP-102
MaximumResolution
±199.9µA±1.999mA±19.99mA±199.9mA±1.999A
Model RangeInternal
ResistanceInput
Protection
AP-102-21AP-102-22AP-102-23AP-102-24AP-102-25
1kΩ100Ω10Ω1Ω
0.1Ω
±10mA±50mA
±150mA±500mA
±3A
100nA1µA10µA
100µA1mA
AP-102- -
10
1415
Range
~ 21
25±600V(Option)
~
Power Supply 1. AC90~132V2. AC180~264V3. DC5V (Isolated)
Output
1. None 2. BCD (TTL)3. BCD (Open Collector)5. None 6. BCD (TTL)7. BCD (Open Collector
(2.5/sec)
(12.5/sec)
48
96
73
B.C.D Output
506.6
92
Min.120
Min
.70
+0.8-0
45+
0.6
-0
Front
Side
Panel cut
Panel thickness0.8 to 5.0mm
1 2 3 4 5 6 7 8 9 1110 12 13 14A B C D E F H J K L M N P R
1 4 1 4
BCD OUT ENABLE
ENABLE
1 14
2 8 2 8 2 8
D.C
OM
D.C
OM
STA
RT
HO
LD
OV
ER
PC
PO
L
100
100
101
101
102
102 103
103
Features
• BCD(option)
• Bright LED 14.2mm(Red)
• AC180~264V, 90~132V, DC5V
• 20mV~200V, 200µA~2A Measurement
• ±600V Measurement(option)
• BCD Open Collector available
BCD Output(Option)
MaximumResolution
±19.99mV±199.9mV±1.999V±19.99V±199.9V
Model RangeInput
ImpedanceInput
Protection
AP-102-10AP-102-11AP-102-12AP-102-13AP-102-14
100MΩ100MΩ100MΩ10MΩ10MΩ
±250V±250V±250V±250V±500V
10µV100µV1mV
10mV100mV
1 2 3 4 5 6 7 8 9 10 11 12 1413 1615 17 18
INPUT DP
0V+5V
DC5V
101102103LOHI CO
M
HO
LD
1 2 3 4 5 6 7 8 9 10 11 12 1413 1615 17 18
INPUT AC POWERSUPPLY
DP
101102103LOHI CO
M
HO
LD50
-60Hz
CAN
GE
EA
RTH
(E)
UPPER
DC TYPELOWER
AC TYPELOWER
1 to 5 V4 to 20 mA
Range Measurement Range Display Input Impedance Input Protection Accuracy
1 V2 A
19 1 MΩ10 Ω
±100 V±100 mA
±(0.2% of FS)±(0.2% of FS)
offset ±9999full scale 0 to ±9999
Power supply for sensor : 12 V DC ±10% 50 mA 24 V DC ±10% 25 mA
Process with sensor power supply
ASAHI KEIKI CO.,LTD. 15
DCV
&A
DC VOLTMETER & AMMETERA5-
SpecificationsDisplay: Main display Red LED 14.2 mm height
Sub display Green LED 8 mm heightConversion Rate: 12.5 times/sec.Maximum Display: 9999Overrange Indication: When input exceeds the maximum display,
display OL or –OLZero Display: Leading zero suppressionDecimal Point: Settable to any digit positionExternal Control: Start/Hold, Peak Hold, Digital ZeroOperating Temperature: 0 to 50°C 35 to 85% RHStorage Temperature: –10 to 70°C less than 60% RHPower Supply: AC 100 to 240V±10% (AC main unit)
DC 9 to 60 V (DC main unit)Power Consumption: Approx 4 VA (at 100 V)Dimensions: 96 mm × 48 mm (H) × 147.5 mm (D) DIN sizeWeight: Approx. 450 gDielectric Strength (AC): Power supply/input terminal/output terminal AC2000 V/1 min.
Input terminal/output terminal DC500 V/1 min.Case/power supply/input terminal output terminal AC2000 V/1 min.
Dielectric Strength (DC): Power supply/input terminal/output terminal DC500 V/1 min.Input terminal/output terminal DC500 V/1 min.Case/power supply/input terminal output terminal AC2000 V/1 min.
Insulation Resistance: DC500 V more than 100 MΩ at the above terminals
Features
•Low Cost
•Power Supply AC100~240 V
DC9~60 V
±99.99 mV
Range Measurement Range Display Maximum Resolution Input Impedance Input Protection Accuracy
1101
10 µV 100 MΩ ±100 V ±(0.1% of FS)offset ±9999
full scale 0 to ±9999
±999.9 mV±9.999 V±99.99 V±600 V
Range Measurement Range Display Maximum Resolution Input Impedance Input Protection Accuracy
12131415
0210 µV1 mV10 mV100 mV
100 MΩ1 MΩ10 MΩ10 MΩ
±100 V±250 V±250 V±600 V
±(0.1% of FS)±(0.1% of FS)±(0.1% of FS)
±(0.15% of FS)
offset ±9999full scale 0 to ±9999
±9.999 mA±99.99 mA±999.9 mA
Range Measurement Range Display Maximum Resolution Input Impedance Input Protection Accuracy
232425
031 µA10 µA100 µA
10 Ω1 Ω
0.1 Ω
±100 mA±500 mA
±3 A
±(0.2% of FS)±(0.2% of FS)±(0.3% of FS)
offset ±9999full scale 0 to ±9999
Input configuration : Single endedMeasuring method : ∆∑typeNormal mode rejection : More than NMR 50dB (50/60 Hz)
Caution: Range 15 UL approval guarantee up to 300VDC
1 to 5 V4 to 20 mA
Range Measurement Range Display Input Impedance Input Protection Accuracy
1 V2 A
18 1 MΩ10 Ω
±100 V±100 mA
±(0.2% of FS)±(0.2% of FS)
offset ±9999full scale 0 to ±9999
Process
DC Voltage, Current
Ordering CodeA5 -
Input
Output
Display boardMain board
0. None 1. HI & LO setpoint2. Analog output3. RS-232C 4. RS-4855. HI & LO setpoint + analog output6. HI & LO setpoint + analog output + RS-232C7. HI & LO setpoint + analog output + RS-4851. Single 2. Multiple1. AC100 - 240 V (±10%) 2. DC9 - 60 V
01. DC voltage (±99.99 mV) 02. DC voltage (±999.9 mV to ±600 V)03. DC current (±9.999 mA to ±999.9 mA)18. 1-5V, 4-20mA19. 1-5V, 4-20mA with EXC
Dimensions
92
96
487
121
45
147.
5
45+
0.6
-0
92 +0.8- 0
MIN
.70
MIN.120
ASAHI KEIKI CO.,LTD.16
DCV
&A
DC VOLTMETER & AMMETERAP-141
Standard 4 1/2 Digit
Dimensions
Connection Diagram
Front
Side
Panel Cutout
48
96
73506.6
92
Min120
Min
70
+0.8-0
45+
0.6
-0
1 2 3 4 5 6 7 8 9 10 11 12 1413 1615 17 18
INPUT
DC POWER
AC POWERD.P
0V +
101 102 103104LO EHI
CO
M
CO
M
HO
LDS
TAR
T
Panel thickness 0.8 to 5.0mm
Internally Connected Lo and D. COM
Ordering Code
Features
•Low Cost
•Bright LED 14.2mm(Red)
•AC180~264V, 90~132V, DC5V, DC24V
•2V~200V Measurement
•±700V Measurement(Option)
AP-141- -
12
1415 ±700V (Option)
Range
~
Power Supply 1. AC90~132V2. AC180~264V3. DC5V (Isolated)4. DC24V (Isolated)
DC Voltage Measurement
SpecificationsInput configuration: Single EndedInput Bias Current: 100PA(Typ.)Conversion Rate: 2.5/secNormal Mode Rejection: More than 50dB(50/60Hz)Zero Stability: Automatic Zero AdjustmentDisplay: LED, 14.2mm 4 1/2 -digitPolarity: A "-" is displayed automaticallyDecimal Point: Settable to any digit positionOverrange Indication: When input exceeds the maximum display,
0000 or -0000 flashesPower Supply: AC90~132V
AC180~264VDC5V±5% 150mA (Max.)DC24V±20% 35mA (Max.)
Operating Temperature: 0~50˚C, 35 to 85%RHPower Consumption: 2VADimensions: 48(H) 96(W) 73(D)mm DIN SizeWeight: Approx. 160g(For AC), 90g(For DC)Dielectric Strength: AC type;Between input(Lo)terminal and earth,
DC500VBetween power supply terminal and inputterminal, earth, common, case, AC1500V/1min.DC type;Between input(Lo) and powersupply(0V), DC500V
Insulation Resistance: DC500V 100MΩ at above terminals
±1.9999V±19.999V±199.99V
Model RangeInput
ImpedanceInput
Protection
AP-141-12AP-141-13AP-141-14
100MΩ1MΩ1MΩ
±100V±250V±500V
100µV1mV
10mV
MaximumResolution
Accuracy:±0.03% rdg ±1 digit (23°C±5°C)
ASAHI KEIKI CO.,LTD. 17
DCV
&A
Ordering Code
Dimensions
Connection Diagram
DC Voltage Measurement
Accuracy:±0.03%rdg ±1digit (23°C±5°C)
SpecificationsInput Configuration: Single EndedInput Bias Current: 100PA (Typ.)Conversion Rate: 2.5/secNormal Mode Rejection: More than 50dB (50/60Hz)Zero Stability: Automatic Zero AdjustmentDisplay: LED 14.2mm 4 1/2-digitPolarity: A "-" is displayed automaticallyDecimal Point: Settable to any digit positionOverrange Indication: When input exceeds the maximum display,
0000 or -0000 flashes.Power Supply: AC90~132V
AC180~264VDC5V ±5%, 170mA (Max.)
Operating Temperature: 0~50°C, 35 to 85%RHPower Consumption: 2VADimensions: 48(H) × 96(W) × 73(D)mm DIN SizeWeight: Approx. 190g (For AC), 125g (For DC)Dielectric Strength: AC type; Between input (Lo) terminal and
earth, DC ±500VBetween power supply terminal and input terminal, earth, common, case, AC1500V/1 min. DC type;Between input (Lo) and power supply (0V), DC ±500V
Insulation Resistance: DC500V 100MΩ at above terminals
BCD Data Output (Isolated from input (Lo))・At Open Collector (option)Measured data: Negative logic transistor "ON" at logic "1"Polarity signal: Transistor "ON" at plus input“OVER” signal: Transistor "ON" at overflow inputPrinting command signal: Transistor "ON" during a period of approx.
1ms at every measurement completionTransistor output capacity:Applied voltage, 30V max.
(NPN) current, 10mA max.Saturated output voltage less than1.2V at 10mA
・At TTL levelMeasured data: Tri-state parallel BCD positive logic latch
outputPolarity signal: "1" level at plus input"OVER" signal: "1" level at overflow inputPrinting command signal: A positive pulse of approx 1ms at every
measurement completionEach signal of the above: TTL level Fanout= 2*Each signal of the above can be changed to negative logic
DC VOLTMETER & AMMETER
AP-142- -
11
1415 ±700V (Option)1D Differial input
(11, 12 range)
Range
~
Output 1. None2. BCD (TTL)3. BCD (Open Collector)
Power Supply
1. AC90~132V
2. AC180~264V3. DC5V (Isolated)
48
96
73
B.C.D Output
506.6
92
Min120
Min
70
+0.8-0
45+
0.6
-0
Front
Side
Panel cut
1 2 3 4 5 6 7 8 9 1110 12 13 14A B C D E F H J K L M N P R
1 4 1 4
BCD OUT
BCD OUT
ENABLE
ENABLE
1 1 14 4
2 8 2 8 2 8
D.C
OM
D.C
OM
HO
LDS
TAR
T
OV
ER
PC
PO
L
KE
Y
101
100 101 102 103 104
100
100
104
101
102
102 103 1032 8
Features
• BCD (Option)
• Bright LED 14.2mm (Red)
• AC180~264V, 90~132V, DC5V
• 200mV~200V Measurement
• ±700V Measurement (option)
• Current Measurement (option)
• BCD Open Collector available (option)
BCD Output (Option)
±199.99mV±1.9999V±19.999V±199.99V
Model RangeInput
ImpedanceInput
Protection
AP-142-11AP-142-12AP-142-13AP-142-14
100MΩ100MΩ1MΩ1MΩ
±250V±250V±250V±500V
100µV100µV1mV
10mV
MaximumResolution
AP-142
1 2 3 4 5 6 7 8 9 10 11 12 1413 1615 17 18
INPUT
DC 5V
AC POWERD.P
0V+5V
101 102 103104LO EAGHI
CO
M
CO
M
HO
LDS
TAR
T
Upper
Lower
ASAHI KEIKI CO.,LTD.18
DCV
&A
DIGITAL PANEL METERAP-200
SpecificationsInput configuration: Single EndedInput Bias: 50PA(TYP)Conversion Rate: 2.5/secDisplay: LED, 10.16mm (Red)Polarity: A "-" is displayed automaticallyDecimal point: Settable to any digit positionOverrange Indication: Flashes 1999 or -1999Power Supply: DC5V ± 5%Operating Temperature: 0~50; 35 to 85%RHPower Consumption: Approx 60mA (TYP)Dimensions: 48(W)24(H)39.7(D)mm DIN sizeWeight: Approx. 30gDielectric Strength: Between LO and case, DC1500V/min.Insulation Resistance: Between LO and case, DC500V more than 500 Ω
Features
•Low cost
•Screw terminal
•1/32 DIN size, Depth 39.7mm
•200mV ~ 200V measurement
MaximumResolution
± 199.9mV ± 1.999V ± 19.99V ± 199.9V
± 100V ± 100V ± 250V ± 500V
100uV 1mV 10mV 100mV
Range InputProtectionModel
AP-200-11AP-200-12AP-200-13AP-200-14
InputImpedance
100MΩ 100MΩ10MΩ10MΩ
Accuracy: ±(0.1% of rdg 1 digit) (23; ± 5;, 35to85%RH)Stability max 2 digit for only AP-200-11
DC Voltage Measurement
Ordering CodeAP-200-
Range
Dimensions
Front
Side
24
48
10.16
4.3
57.7
39.7
Panel cutout
Back
45
65mm
35mm
+0.6-0
22.2+
0.3-
0
Panel thickness 0.8 to 3.5mm
Connection Diagram
1 2 3 4 5
Terminal No. Description1 Input HI2 Input LO3 HOLD4 Power supply 0V5 Power supply +5V
ASAHI KEIKI CO.,LTD. 19
DCV
&A
Ordering Code
Dimensions
Connection Diagram
DC Voltage Measurement
Accuracy:±0.1% rdg. ±1 digit (23°C5°C) Stability Max. 2 digits for only AP-201A-11
SpecificationsInput configuration: Single Ended.Input Bias Current: 50PA(Typ.)Conversion Rate: 2.5/secNormal Mode Rejection: 40dB(Typ.)(50/60Hz)Zero Stability: Automatic Zero AdjustmentDisplay: LED, 10.2mm 3 1/2 -digitPolarity: A "-" is displayed automaticallyDecimal Point: Settable to any digit positionOverrange Indication: Flashes 1 or -1 of the most significant digit for
an input signal exceeding the maximumdisplay range.
Power Supply: DC5V±5%, 60mAOperating Temperature: 0~50°C, 35 to 85%RHPower Consumption: Approx. 60mADimensions: 24(H) × 48(W) × 73(D)mm DIN SizeWeight: Approx. 40gDielectric Strength: Between input(Lo) terminal and mounted plate.
AC1500V/1 min.Insulation Resistance: DC500V 100MΩ at above terminals
DC VOLTMETER & AMMETERAP-201A
AP-201A-
11
14Range
~
24
48
73
514.8
45
Min.65
Min
.35
+0.6-0
22.2+
0.3
-0
Front
Side
Panel cut
1 2 3 4 5 6 7 8 9 10
Operable only wheninput Lo and power supply(0V) are extermally connected
POWERD.PINPUT
101LOHI
CO
M 102 103 0V +5V
HO
LD
Features
• Low Cost
• Bright LED 10.2mm(Red)
• DC5V(Non-Isolated)
• 200mV~200V Measurement
Standard 3 1/2 Digit
±199.9mV±1.999V±19.99V±199.9V
Model RangeInput
ImpedanceInput
Protection
AP-201A-11AP-201A-12AP-201A-13AP-201A-14
100MΩ100MΩ10MΩ10MΩ
±100V±100V±250V±500V
100µV1mV
10mV100mV
MaximumResolution
ASAHI KEIKI CO.,LTD.20
DCV
&A
Ordering Code
Dimensions
Connection Diagram
DC Voltage Measurement
Accuracy: ±0.1% rdg. ±1 digit (23°C ±5°C)
DC Current Measurement
Accuracy: ±0.2% rdg. ±1 digit (23°C ±5°C)±0.3% rdg. ±1 digit only for AP-202A-25
* These resistors are connected to the outside of the unit.
SpecificationsInput Configuration: Single EndedInput Bias Current: 50PA (Typ.)Conversion Rate: 2.5/sec or 12.5/sec (50Hz), 15/sec (60Hz)Normal Mode Rejection: 40dB (Typ.) (50/60Hz)Zero Stability: Automatic Zero AdjustmentDisplay: LED, 10.2mm 3 1/2-digitPolarity: A "-" is displayed automaticallyDecimal Point: Settable to any digit positionOverrange Indication: When input exceeds the maximum display,
1999 flashes.Power Supply: DC5V ±5%, 120mA
DC12V ±20%, 50mADC24V ±20%, 25mA
Operating Temperature: 0~50°C, 35 to 85%RHPower Consumption: 650 mWDimensions: 24(H) × 48(W) × 73(D)mm DIN SizeWeight: Approx. 50gDielectric Strength: Between Input (Lo) terminal and power supply
(0V), DC ±500VBetween power supply terminal and case,AC1500V/1 min.
Insulation Resistance: DC500V 100MΩ at above terminals
DC VOLTMETER & AMMETERAP-202A
±199.9µA±1.999mA±19.99mA±199.9mA±1.999A
Model RangeInput
ResistanceInput
Protection
AP-202A-21AP-202A-22AP-202A-23AP-202A-24AP-202A-25
1kΩ100Ω10Ω*1Ω
*0.1Ω
±10mA±50mA
±150mA±500mA
±3A
100nA1µA10µA
100µA1mA
MaximumResolution
AP-202A- -
Range
Output 1. None2. BCD (2.5/sec)6. BCD (12.5/sec 50Hz)7. BCD (15/sec 60Hz)
Power Supply 3. DC5V (Isolated)4. DC24V (Isolated)5. DC12V (Isolated)
-
BCD Out 1. None2. TTL3. Open Collector
11
14
~ 21
25
~
24
48
73
B.C.D Output (option)
514.8
45
Min.65
Min
.35
+0.6-0
22.2+
0.3
-0
Front
Side
Panel cut
2 4 6 81 3 5 7
10 1211 13
14
1 4 1 4
BCD OUT
BCD OUT
EN
AB
LE
1 14
2 8 2 8 2 8
CO
MC
OM
OV
ER
HO
LDPC
PO
L100
100
101
101
102
102
103
91615 19 21 23 25
1817
20 22 24 26
Features
• BCD (option)
• DC5V, DC12V, DC24V (Isolated)
• Bright LED 10.2mm (Red)
• Conversion Rate 2.5/sec or 12.5/sec (50Hz),
15/sec (60Hz)
• 200mV~200V, 200µA~2A Measurement
ISOLATED Power Supply
±199.9mV±1.999V±19.99V±199.9V
Model RangeInput
ImpedanceInput
Protection
AP-202A-11AP-202A-12AP-202A-13AP-202A-14
100MΩ100MΩ10MΩ10MΩ
±100V±100V±250V±500V
100µV1mV
10mV100mV
MaximumResolution
Panel thickness 0.8 to 3.5mm
1 2 3 4 5 6 7 8 9 10
POWERD.PINPUT
101LOHI
CO
M
BLA
NK
ING 102 103 0V +
HO
LD
Upper
Lower
ASAHI KEIKI CO.,LTD. 21
DCV
&A
DC VOLTMETER & AMMETERAP-244A
BCD Output(Option)
Dimensions
Connection Diagram
Front
Side
Panel Cutout
24
48
87B.C.D (option)
655
±1
45
Min.65
Min
.35
+0.6-0
22.2+
0.3
-0
2 4 6 8
1 3 5 7 9
10 12 14 16 18 20 22 24 26
1311 15 17 2119 23 25
1 4 1 4
BCD OUT
BCD OUT
EN
AB
LE
1 1 14 4
2 8 2 8 2 8
CO
MC
OM
HO
LD
OV
ER
PC
PO
L100 101 102 103 104
100 101 102 103
2 8
1 2 3 4 5 6 7 8 9 10
POWERD.PINPUT
101LOHI 102 103 104 0V +
HO
LDS
TAR
TCO
M
Ordering Code
Features
•5V, 24VDC(Isolated)
•Bright LED, 8mm(Red)
•2V to 200V Measurement
•BCD Output(option)
AP-244A- - -
Power Supply 3. 5 to 12VDC 4. 12 to 24VDC
Type of BCD 1. none2. TTL3. Open collector
Output
1. none2. BCD(2.5/sec)6. BCD(12.5/sec)7. BCD(15/sec)
Range 11 1V
14 2A
~
DC Voltage Measurement
SpecificationsInput Configuration: Single endedInput Bias Current: 100PA(Typ.)Conversion Rate: 2.5/sec, 12.5(50Hz), 15(60Hz)/secNormal Mode Rejection: NMR50dB(50/60Hz)Display: LED 8mm 4 1/2 digitPolarity: A "-" is displayed automaticallyDecimal Point: Settable to any digit positionOverrange Indication: When input exceeds the maximum display,
0000 flashesPower Supply: 5VDC±5%, 24VDC±20%Operating Temp.: 0~50˚C, 35 to 85%RHPower Consumption: 120mA at 5VDC(Max.)
30mA at 24VDC(Max.)Dimensions: 24(H) 48(W) 87(D)mm Din sizeWeight: 50gDielectric Strength: Between input(Lo)terminal and mounted plate,
AC1500V/1 min.Between input(Lo)terminal and powersupply(0V), 500VDC/1 min.
BCD Data Output(Isolated from input(Lo))•At Open collectorMeasured data: Negative logic transistor "ON" at logic "1"Polarity signal: Transistor "ON" at plus input"OVER" signal: Transistor "ON" at overflow inputPrinting command signal: Transistor "ON" during a period of approx. 100
to 200ms at every measurement completionTransistor output capacity: Applied voltage, 30V max
current, 10mA maxSaturated output voltage less than 1.2V at10mA
•AT TTL levelMeasured date: Tri-state parallel BCD positive logic latch
outputPolarity signal: "1" level at plus input"OVER" signal: "1" level at overflow inputPrinting command signal: A positive pulse of approx 100 to 200ms at
every measurement completionEach signal of the above: TTL level Fanout=2* Each signal of the above can be changed to negative logic
±199.99mV±1.9999V±19.999V±199.99V
Model RangeInput
ImpedanceInput
Protection
AP-244A-11AP-244A-12AP-244A-13AP-244A-14
100MΩ100MΩ1MΩ1MΩ
±100V±100V±250V±250V
10µV100µV1mV
10mV
MaximumResolution
Accuracy:±0.03% rdg ±1 digit (23°C±5°C)
Upper
Lower
Panel thickness 0.8 to 3.5mm
ASAHI KEIKI CO.,LTD. 25
DCV
&A
Ordering Code
Dimensions
Connection Diagram
DC Voltage Measurement
Accuracy: ±0.1% rdg. ±1 digit (23°C ±5°C)
SpecificationsInput Configuration: Single EndedInput Bias Current: 50PA (Typ.)Conversion Rate: 2.5/secNormal Mode Rejection: 40dB (Typ.) (50/60Hz)Zero Stability: Automatic Zero AdjustmentDisplay: LED, 14.2mm 3 1/2-digitPolarity: A "-" is displayed automaticallyDecimal Point: Settable to any digit positionOverrange Indication: When input exceeds the maximum display,
1999 flashesPower Supply: DC5V ±5%, 80mA (Max.)Operating Temperature: 0~50°C, 35 to 85%RHPower Consumption: 400mWDimensions: 36(H) × 72(W) × 29(D)mm DIN SizeWeight: Approx. 35gDielectric Strength: Between input (Lo) terminal and case,
AC1500V/1 min.Between input (Lo) terminal and power supply(0V), DC500V
Insulation Resistance: DC500V 100MΩ at above terminals
DC VOLTMETER & AMMETERAP-301
AP-301-
Option
-
Range ~
A. Screw Terminal, 4-20 mA(Range code 11)
B. Screw Terminal, Scaling(Range code 11-14)
C. Screw Terminal, Range Select(Range code 12-14)
D. Screw Terminal, DC-DCIsolated power supply(5V DC)∗BLANK-None
11 1V
14
36
72
2916.34.8
Min.58
+0.6
-0
+0.7 -068
Min.96
33Front
Side
Panel cut
1
2
3
4
5
6
7
8
9
HI
LOINPUT
POWER
D.P
BLANKING
HOLD
103
102
101
0V
+5V
Operate only when input Lo is externally connected to power (0V)
Features
• Compact Size, 36(H) × 72(W) × 29(D)mm
• Bright LED, 14.2mm (Red)
• DC5V(Non-Isolated)
• 200mV~200V Measurement
• Isolated DC24V Available (Option A or D)
Compact Size, 14.2mm LED
±199.9mV±1.999V±19.99V±199.9V
Model RangeInput
ImpedanceInput
Protection
AP-301-11AP-301-12AP-301-13AP-301-14
100MΩ100MΩ10MΩ10MΩ
±100V±100V±250V±500V
100µV1mV
10mV100mV
MaximumResolution
Panel thickness 0.8 to 3.5mm
ASAHI KEIKI CO.,LTD.26
DCV
&A
Ordering Code
Dimensions
Connection Diagram
DC Voltage Measurement
Accuracy: ±0.1% rdg. ±1 digit (23°C ±5°C)
SpecificationsInput Configuration: Differential (11/12-range), Single Ended
(13/14-range)Input Bias Current: 50PA (Typ.)Conversion Rate: 2.5/secNormal Mode Rejection: 40dB (Typ.) (50/60Hz)Zero Stability: Automatic Zero AdjustmentDisplay: LED, 14.2mm 3 1/2-digitPolarity: A "-" is displayed automaticallyDecimal Point: Settable to any digit positionOverrange Indication: Display 1 or -1 of the most significant digit for
an input signal exceeding the maximumdisplay range.
Power Supply: DC5V ±5%, 120mAOperating Temperature: 0~50°C, 35 to 85%RHPower Consumption: Approx. 120mADimensions: 48(H) × 96(W) × 34.5(D)mm DIN SizeWeight: Approx. 50gDielectric Strength: Between input (Lo) terminal and mounted
plate. AC1500V/1 min.Insulation Resistance: DC500V 100MΩ at above terminals
DC VOLTMETER & AMMETERAP-501A
AP-501A-
Range11
14
~
48
96
34.5 12.26.3
92
Min.120
Min
.70
+0.8-0
45+
0.6
-0
Front
Side
Panel cut
1 2 3 4 5 6 7 8 9 10
POWERD.PINPUT
101LOHI 102103 0V +5V
AN
ALO
G・
G
HO
LD
CO
M
When use single ended, connect terminal ② and ③ (COMMON and 0V Terminal is internally connected)
Features
• Low Cost
• Bright LED, 14.2mm (Red)
• Thin Case (Depth 34.5mm)
• DC5V(Non-Isolated)
• 200mV~200V Measurement
Super Thin Case, Low Cost
±199.9mV±1.999V±19.99V±199.9V
Model RangeInput
ImpedanceInput
Protection
AP-501A-11AP-501A-12AP-501A-13AP-501A-14
100MΩ100MΩ10MΩ10MΩ
±100V±100V±250V±500V
100µV1mV
10mV100mV
MaximumResolution
Panel thickness 0.8 to 3.5mm
ASAHI KEIKI CO.,LTD. 27
DCV
&A
DC VOLTMETER & AMMETERAP-502
ISOLATED Power Supply
Dimensions
Connection Diagram
Front
Side
Panel Cutout
48
96
3212.26.3
92
Min.120
Min
.70
+0.8-0
45+
0.6
-0
1 2 3 5 6 7 8 9 10 11 12 1514134
POWERD.P
ISERIAL DATA OUT
LOHI 101102103 0V +5V
COMIN PUT COM PC HOLD
STB SOUT
Ordering Code
Features
•Low Cost
•Bright LED 14.2mm(Red)
•Serial Data Output
•Thin Case(Depth 32mm)
•DC5V(Isolated)
•200mV~200V, 200A~2A Measurement
AP-502-
Range11
14
~ 21
25
1V
2A
~
DC Voltage Measurement
SpecificationsInput configuration: Single EndedInput Bias Current: 50PA(Typ.)Conversion Rate: 2.5/secNormal Mode Rejection: More than 40dB(50/60Hz)Zero Stability: Automatic Zero AdjustmentDisplay: LED, 14.2mm 3 1/2-digitPolarity: A "-" is displayed automaticallyDecimal Point: Settable to any digit positionOverrange Indication: When input exceeds the maximum display,
1999 flashes.Power Supply: DC5V±5%, 120mA(Max.)Operating Temperature: 0~50˚C, 35 to 85%RHPower Consumption: Approx. 120mADimensions: 48(H) 96(W) 32(D)mm DIN SizeWeight: Approx. 60gDielectric Strength: Between input(Lo)terminal and power
supply(0V), DC500V.Between input(Lo)terminal and mounted plate.AC1500V/1 min.
Insulation Resistance: DC500V 100MΩ at above terminals
±199.9mV±1.999V±19.99V±199.9V
Model RangeInput
ImpedanceInput
Protection
AP-502-11AP-502-12AP-502-13AP-502-14
100MΩ100MΩ10MΩ10MΩ
±250V±250V±250V±500V
100µV1mV
10mV100mV
MaximumResolution
Accuracy: ±0.1% rdg. ± 1 digit(23˚C±5˚C)
DC Current Measurement
±199.9µA±1.999mA±19.99mA±199.9mA±1.999A
Model RangeInput
ResistanceInput
Protection
AP-502-21AP-502-22AP-502-23AP-502-24AP-502-25
1KΩ100Ω10Ω1Ω
0.1Ω
±10mA±50mA
±150mA±500mA
±3A
100nA1µA10µA
100µA1mA
MaximumResolution
Accuracy: ±0.2% rdg.±1 digit(23˚C±5˚C) ±0.3% rdg.±1 digit only for AP-502-25
Panel thickness 0.8 to 3.2mm
ASAHI KEIKI CO.,LTD.28
DCV
&A
Ordering Code
Dimensions
Connection Diagram
DC Voltage Measurement
Accuracy: ±0.1% rdg. ±1 digit (23°C ±5°C)
SpecificationsInput Configuration: Differential (11/12-range)
Single Ended (13/14-range)Input Bias Current: 50PA (Max.)Conversion Rate: 2.5/secNormal Mode Rejection: 40dB (Typ.) 50/60HzZero Stability: Automatic zero adjustmentDisplay: LCD, 12.7mm 3 1/2-digitPolarity: A "-" is displayed automaticallyDecimal Point: Settable to any digit positionOverrange Indication: Display 1 or -1 of the most significant digit for
an input signal exceeding the maximumdisplay range.
Power Supply: DC5V ±5%Operating Temperature: 0~50°C, 35 to 85%RHPower Consumption: Approx. 15mWDimensions: 48(H) × 96(W) × 34.5(D)mm DIN SizeWeight: Approx. 60gDielectric Strength: Between input terminal (Lo) and mounting
panel DC500V.Insulation Resistance: DC500V 100MΩ at above terminals
DC VOLTMETER & AMMETERAP-520A
AP-520-
Range11
14
~
48
96
34.5 12.26.3
92
Min.120
Min
.70
+0.8-0
45+
0.6
-0
Front
Side
Panel cut
1 2 3 4 5 6 7 8 9 10
POWERDECIMALPOINT
INPUT
101LOHI 102103 0V +5V
AN
ALO
G・
G
HO
LD
CO
M
When use single ended, connect terminal ② and ③ (COMMON and 0V Terminal is internally connected)
Features
• LCD, 12.7mm
• Thin Case (Depth 34.5mm)
• DC5V(Non-Isolated)
• 200mV~200V Measurement
LCD Display
±199.9mV±1.999V±19.99V±199.9V
Model RangeInput
ImpedanceInput
Protection
AP-520-11AP-520-12AP-520-13AP-520-14
100MΩ100MΩ10MΩ10MΩ
±100V±100V±250V±500V
100µV1mV
10mV100mV
MaximumResolution
Panel thickness 1.0 to 3.2mm
ASAHI KEIKI CO.,LTD. 29
DCV
&A
Dimensions
Connection Diagram
DC Voltage Measurement
Accuracy:±(0.03% of rdg +1 digit ) (23°C±5°C 45~75%RH)
SpecificationsInput configuration: Single endedInput bias current: 100 pA (TYP.)Conversion rate: 2.5/secNormal mode rejection: More than NMR50dB (50/60 Hz)Maximum display: 19999Overrange indication: When input exceeds the maximum display,
0000 flashesDisplay: LED, 14.2 mm (Red)Polarity: A “-” is displayed automaticallyHold: START/HOLD terminal and 0 V shorted or level
"0"Start: START/HOLD terminal and 0 V open or level
"1"Decimal point: Settable to any digit positionOperating temperature: 0~50°C 35~85%RHPower supply: DC 5 V±5%Power consumption: 75 mA (Max.)Dimensions: 48(H) × 96(W) × 34.5(D)mm DIN sizeWeight (unit): Approx. 60 gDielectric strength: Between LO and case, AC 1500 V/l min.Insulation resistance: More than DC 500 V 100 MΩ at the above
terminalsAccessory: Connector, instruction manual
Ordering Code
DC VOLTMETER & AMMETERAP-540
48
96
34.5
12.26.3
Min
.70
Min.120
92+0.8-0
45+
0.9
-0
Front
Side
Panel cut
1 2 3 4 5 6 7 8 9 10
HI
INPUT DC POWERD.P
L0 NC 104 103 102 101 0V +5V
START/HOLD
Features
• Bright LED, 14.2 mm (Red)
• Thin Case (Depth 34.5 mm)
• Power supply DC 5V (Non-isolated)
• 200 mV~200 V measurement
MaximumResolution
±199.99mV±1.9999V±19.999V±199.99V
Model RangeInput
ImpedanceInput
Protection
AP-540-11AP-540-12AP-540-13AP-540-14
100MΩ100MΩ1MΩ1MΩ
±100V±100V±250V±500V
10µV100µV1mV
10mV
AP-540-
Range
11121314
Panel thickness 0.8 to 3.2mm
ASAHI KEIKI CO.,LTD. 31
DCV
&A
OPEN CASE METERAH-330, 331
EASY Installation
Dimensions
Connection Diagram
Parts
NO.1
4-2.8φ
4-2.8φ
000000000
000000000
14.2
8
000000000
000000000
14.2
8
4.2
3.112.47 12.47 12.47
*A
*B
1.6
19
2.54
0.64
17.78
NO.1
NO.8
19
2.54
0.64
17.78
8.54
2.54
PartsOption
Option
4.2
2
2525
*A
1.6
5.5
8.54
2.54
23 1129.5
2010.5
59POL DP2 DP1
DP2DP3 DP1
65 (mm)
(mm)
12.752.25
*B2329.5
10.5 14.5
59
65
8
OVF
AH-330
AH-331
1 HIINPUT
POWER
D.P
2
3
4
5
6
7
LO
HOLD
101
102
0V
+5V
1 HIINPUT
POWER
D.P
2
3
4
5
6
7
8
9
LO
101
102
103
0V
COM
HOLD
+5V
AH-331
OPTION
AH-330
Features
•Uncased, 3 digits(AH-330) 3 1/2 digits(AH-331)
•Bright LED, 14.2mm(Red)
•Hold for AH-331(option)
•Power Supply DC5V±5%
DC Voltage Measurement
SpecificationsInput Configuration: Single EndedInput Bias Current: 50PA(Typ.)Conversion Rate: 2.5/secNormal Mode Rejection: 40dB(Typ.)Zero Stability: Automatic zero adjustmentDisplay: LED, 14.2mmPolarity: A "-" is displayed automaticallyDecimal Point: Settable to any digit positionOverrange Indication: When input exceeds the maximum display,
lights up "OVER" LED(AH-330)or 1999flashes(AH-331)
Power Supply: DC5V±5%Operating Temperature: 0~50˚C, 35 to 85%RHPower Consumption: AH-330 75mA, AH-331 80mADimensions: 29.5(H) 65(W) 18.2(D)mmWeight: Approx. 20g
±99.9mV±0.999V
±199.9mV±1.999V
Model RangeInput
ImpedanceInput
Protection
AH-330-11AH-330-12AH-331-11AH-331-12
100MΩ100MΩ100MΩ100MΩ
±100V±100V±100V±100V
100µV1mV
100µV1mV
MaximumResolution
Accuracy: ±0.1% rdg.±1 digit(23˚C±5˚C)
Ordering Code
AH-330-331 Range
11
12
~
(AH-331)
ASAHI KEIKI CO.,LTD.32
DCV
&A
Ordering Code
Dimensions
Connection Diagram
DC Voltage Measurement
Accuracy: 0.1% rdg.±1 digit(23°C±5°C)
SpecificationsInput Configuration: Single EndedInput Bias Current: 100PA(Typ.)Conversion Rate: 2.5/secNormal Mode Rejection: 40dB(Typ.)Zero Stability: Automatic zero adjustmentDisplay: LCD, 10.2mmPolarity: A "-" is displayed automaticallyDecimal Point: Settable to any digit positionOverrange Indication: When input exceeds the maximum display,
display 1 or -1 of the most significant digitPower Supply: DC5V±5%Operating Temperature: 0~50°C, 35 to 85%RHPower Consumption: 3mA(Max.)Dimensions: 29.5(H) × 65(W) × 16.5(D)mmWeight: Approx. 17g
OPEN CASE METERAH-381
AH-381-
Range 1112
4-2.8φ
25
29.5
50.8
4.2
2.82.8
10.2
122.54
6.1+0.3
1.6
17.78
P-2.54×6
0.64
24.1
8.54
2329.5
59
64.5
mVA
MkΩ
DC
AC
パーツ
1 HIINPUT
POWER
2
3
4
5
6
7
LO
HOLD
COM
0V
+5V
Features
• LCD, 10.2mm
• Engineering units available
• Power supply 5V DC±5%
• 200mV~2V Measurement
LCD Display
±199.9mV±1.999V
Model RangeInput
ImpedanceInput
Protection
AH-381-11AH-381-12
100MΩ100MΩ
±100V±100V
100µV1mV
MaximumResolution
ASAHI KEIKI CO.,LTD. 33
ComparatorSETPOINT COMPARATOR
AM-123
SpecificationsInput Configuration: Single EndedConversion Rate: 12.5/sec(50Hz), 15/sec(60Hz)Normal Mode Rejection: NMR50dB or more(50/60Hz)Display: LED, main display 14.2mm
sub display 8mmPolarity: A "-" is displayed automaticallyOverrange Indication: When input exceeds the maximum display,
display OL or -OLMaximum Display: ±9999Decimal Point: Settable to any digit positionZero Display: Leading zero suppressionExternal Control: Hold, Start, Digital Zero, Peak, Peak-valley, ValleyMemory Backup: EEPROMOperating Temperature: 0~50˚C, 35 to 85%RHPower Supply: AC90~264V(50/60Hz)Power Consumption: 4VA(TYP)(At AC100V)Dimensions: 48(H) 96(W) 98(D)mm DIN sizeWeight: Approx 280gDielectric Strength: Between input/compare output DC500V/1 min
Between power supply and input, case, compareoutputAC2100V/1 min
Insulation Resistance: DC500V 100MΩ or more at above terminalsDielectric Noise: Power supply normal/common mode ±1500VAccessories: Instruction manual, unit label, terminal coverCompare Control System: MicrocomputerSetting Range: -9999~0~+9999Comparative Condition: High setpoint < Indication / HI
High setpoint > Indication > Low setpoint / GOLow setpoint > Indicatyion / LO
Relay Contact Capacity: AC125V 0.5A Resistive loadDC28V 1A Resistive load
Photocoupler Capacity: Voltage MAX. 30VCurrent MAX. 50mASaturation voltage less than 1, 2V at 50mA
Hysteresis: 1 to 999 digit at each setpoints
Features
•Three colour display(red, green, amber)
•Two-setpoint(Hi & Lo)
•Digital Zero, Peak Hold(option)
Display± 99.99mV± 999.9mV± 9.999V± 99.99V
1-5 V
Range Input ProtectionModel
AM-123-11AM-123-12AM-123-13AM-123-14AM-123-1V
Input Impedance100MΩ 100MΩ1MΩ1MΩ1MΩ
± 250VOffset ± 9999
Fullscale ± 9999
Display± 999.9µA± 9.999mA± 99.99mA± 999.9mA
4-20mA
Range Input ProtectionModel
AM-123-22AM-123-23AM-123-24AM-123-25AM-123-2A
Internal Resistance100Ω10Ω1Ω
0.1Ω51Ω
± 50mA± 150mA± 500mA
± 3A± 70mA
Offset ± 9999Fullscale ± 9999
Accuracy: (0.3% of rdg 2 digit) (23˚C5˚C 35 to 85%RH)
DC Current Measurement
Accuracy: (0.1% of rdg 2 digit) (23˚C5˚C 35 to 85%RH)(0.3% of rdg 2 digit) for 25 range
DC Voltage Measurement Ordering CodeAM-123- 1-
Range
Comparator output 1. Relay 2. Photocoupler
Dimensions
Connection Diagram
Front
Side
96
48
899
92
Min
.70
+0.8-0
45+
0.6
-0
HI GO LO
( ):PHOTO COUPLER
① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨
a c b a c b a c b
(c) (e) (c) (e) (c) (e)
① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ HI S/H DZ PH NC
POWERLO COM
Panel thickness 0.8 to 5mm
Upper terminal
Lower terminal
Panel cutout
ASAHI KEIKI CO.,LTD.34
Com
para
tor
Ordering Code
Dimensions
Connection Diagram
DC Voltage Measurement
Accuracy : ± (0.03% of rdg +2 digit) (23°C ± 5°C 35 to 85%RH)
DC Current Measurement
Accuracy : ± (0.1% of rdg +2 digit) (23°C ± 5°C 35 to 85%RH)※Accuracy is less than 1 (FSC-OFC) / (FIN-OIN)
Specifications Measuring Section
Input configuration: Single endedConversion rate: 12.5 times/sec(50Hz),15 times/sec(60Hz)Noise rejection ratio: NMR50dB or more (50/60Hz)Display: Red LED, 8mm heightPolarity display: Automatic “-” display when the computation
result is minusOverrange warning: When input exceeds the maximum display,
display OL or -OL Maximum display: ± 9999Decimal point: Settable to any digit positionZero display: Leading zero suppression
Common Section
Memory backup: EEPROM (rewrite 100,000 times)Operating temp.: 0 to 50°C 35 to 85%RHStorage temp.: -10 to 70°C (less than 60%RH)Power supply: DC24V ± 20%Power consumption: 85mA (TYP) at DC24VDimensions: 48mm(W) × 24mm(H) × 388mm(D)Weight: approx.100g (unit only)Dielectric strength: Input terminal (LO) and comparator output,
ANALOG (-), DC500V/min.Power supply (OV) and input (LO), comparatoroutput, ANALOG (-), case, DC500V/min.Input terminal (LO) and case AC1500V/min.
Insulation resistance: DC500V more than 100MΩ at the above terminalsExcitation supply: DC24V ± 10% 25mA ripple less than 200mVp-pAccessories: Instruction manual, rubber paking, terminal
Output Specification Analog Output (isolated input LO)
Can adjust analog output to meet display.※Ripple for resistive load 250Ω, 20mA
SETPOINT COMPARATORAM-213
AM-213 - -
Comparator output 1. Relay2. Photocoupler
Analog output 1. None3. 4 to 20mA
Input code
11. ± 99.99mV12. ± 999.9mV13. ± 9.999V1V. 1 to 5V2A. 4 to 20mA
Features
• NEMA 4 front panel (IP66)
• Excitation power supply DC24V
• Analog output (4 to 20mA) option
• HI and LO setpoints
• 1/32 DIN size
ModelAM-213-11AM-213-12AM-213-13AM-213-1V
Range± 99.99mV± 999.9mV± 9.999V1 to 5 V
Display
OFFSET ± 9999FULLSCALE ± 9999
Input Impedance100MΩ 100MΩ 1MΩ 1MΩ
Input Protection± 250V± 250V± 250V± 250V
Model
AM-213-2A
Range
4 to 20mA
Display OFFSET ± 9999
FULLSCALE ± 9999
Input Impedance
50Ω
Input Protection
± 60mA
Model
AM-213-2A
Range
4 to 20mA
Display OFFSET ± 9999
FULLSCALE ± 9999
Input Impedance
50Ω
Input Protection
± 60mA
HI
E M
48
24
LO
88
22
6.5
11.5
45.0
MIN 65
+0.6-0
22.2
MIN
35
+0.
3-
0Front
Side
Panel cut
① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ ⑩ ⑪
INPUT EXC HI COM LO DC POWERANALOG
OUT
HI LO 0V +24V a a 0V +24Vc
c ce
+
-
Panel thickness 0.8 to 5.0mm
ASAHI KEIKI CO.,LTD. 35
ComparatorSETPOINT COMPARATOR
AM-215 Featuers
• HI and LO set-point
• Bright LED 8mm (Red)
• 1 to 5V, 4 to 20mA Measurement
• Power Supply DC24V ±20% (Isolated)
• Offset +/–9999 adjustable
• Fullscale +/–9999 adjustable
InputImpedance100M ohm100M ohm1M ohm1M ohm
InputProtection
±100V±100V±250V±250V
Model
AM-215-11AM-215-12AM-215-13AM-215-1V
Range
±99.99mV±999.9mV±9.999V1 to 5V
Display AdjustableOffset±9999Fullscale±9999
Accuracy: ±0.03% rdg. ±2 digit (23˚C±5˚C)
InputImpedance
50 ohm
InputProtection
±60mA
Model
AM-215-2A
Range
4 to 20mA
Display AdjustableOffset±9999Fullscale±9999
Accuracy: ±0.1% rdg. ±2 digit (23˚C±5˚C)
DC Voltage Meaurement
DC Current Measurement
Specifications Measurement sectionInput configuration: Single endedOperation method: Dual slopeInput Bias Current: 50PA (Typ.)Conversion rate: Max. 12.5/sec. (50Hz) or 15/sec. (60Hz)Display: LED, 8mm (Red), 4 digitsPolarity: A “-” is displayed automaticallyOverrange indication: When input exceeds the maximum display,
oL or –oL flashesMaximum display: ±9999 (4 digit)Decimal point: Settable at any position (By pressing sheet
switch)Zero display: Reading “zero” suppression
Comparison sectionControl method: Computation by microcomputerSetting range: –9999 to 9999Conparison condition:
Measured value > High limit set-value – HILow limit set value Measured value High limit set value – GOLow limit set value > Measured value – LO
Setting condition: Low limit set value < High limit set valueHysteresis: 1 to 999 digit for each set pointRelay contact capacity: DC24V resistive road
External control sectionDigital zero: Short DZ terminal and COM terminal or level
“0”.Then digital zero “ON”.
Excition power supply sectionExcition power supply: DC24C ±5%, 25mA
Analog output section (impossible both of Analog output andRS-485 selected)
Output function: DC4 to 20mA or DC0 to 10VOutput specification
RS-485 output section (impossible both of Analog output andRS-485 selected)
Synchronous method: Start and stopCommunication method: 2-wire system half duplex
(Polling and selecting)Transmission speed: 19200bps/9600bps/4800bps/2400
bpsStart bit: 1 bitData length: 7 bitError detection: Even parity (BCC)Stop bit: 2 bitCharacter code: ASCII codeTransmission control: No protocolSignal name used: Non-reversible output (+),
Reversible (–)No. of connectable meters: Up to 31 metersLine of length: Up to 500m in total
Common SpecificationsMemory backup: EEPROM (rewrite 100,000 times)Operating temperature: 0 to 50˚C, 35 to 85%RHStorage temperature: –20 to 70˚C, less than 60%HHPower supply: DC24V ±20%Power consumption: Approx. 4WDimensions: 24(H) 48(W) 87.5(D) DIN sizeWeight: Approx. 100gDielectic strengh: Between power supply (0V), input
terminal and each output terminalDC500V/1 min.Between input terminal and eachoutput terminal DC500V/1 min.Between case, power supply, inputterminal and each output terminalDC500V/1 min.
Insulation resistance: DC500V more than 100M ohm atabove terminals.
Accessories: Instruction manual, settingprocedure
RippleLess than 25mVp-pLess than 50mVp-p
Type4 to 20mA0 to 10V
Risistive load0 to 250 ohmMore than 10K ohm
Accracy±(0.5% of FS)±(0.5% of FS)
ASAHI KEIKI CO.,LTD.36
Com
para
tor
Connection Diagram
Dimensions
Panel Cut Out
Ordering Code
SETPOINT COMPARATORAM-215
AM-215- -
Input range
Comparater output
Option output
11. 11 range (±99.99mV) 12. 12 range (±999.9mV) 13. 13 range (±9.999V) 1V. 1V range (1-5V) 2A. 2A range (4-20mA)
1. Relay 2. Photo coupler
1. None 4. RS-485 6. Analog output (4-20mA) 7. Analog putput (0-10V)
1 2 3 4 5 6 7 8 9
POWER !
10 11 12 13 14 15 16 17 18
+24V 0V COM a c a c a c
HI GO LO
EXC(c) (e) (c) (e) (c) (e)
+V0V
POWER
HI LO + - DZ
INPUT TERMINATORANALOGOUT or RS485
3.5 84.3
48.0
24.0
HI LO
E M
45.0+0.6-0
22.2
+0.
3-0
MIN 65
MIN
35
ASAHI KEIKI CO.,LTD. 37
Comparator
Comparison condition:
Comparison relay output: Contact capacity250 V AC 0.2 A Resistive load120 V AC 0.5 A Resistive load28 V DC 1 A Resistive load
Photo coupler output: Voltage = Max. 30 V(NPN) Current = Max. 50 mA
Saturation voltage = less than 1.2 Vat 50 mA
Hysteresis: 1 to 999 digit for each set pointExternal control: Relay reset
Shorted COM terminal and R.REterminal or level "0"Level "0" : 0 to 1.5 VLevel "1" : 3.5 to 5 VInput current : less than -2 mA
Common blockMemory backup: EEPROM (rewrite 100,000 times)
back up 10 yearsOperating temp: 0 to 50°C 35 to 85% RH (No
condensation)Storage temp: -10 to 70°C less than 60% RHPower supply: 90 to 264 V AC (50 Hz/60 Hz)Power consumption: Approx 10 VA typ (at 100 V AC)Dimensions: 96 mm(W) 348 mm(H) 3148 mm(D)
DIN sizeWeight (unit only): Approx 450 gDielectric strength: Input/COM, EXC (0 V), comparative
output, 500 V DC/1 min.Input/COM of each output(BCD:FD.COM, ANALOG:-, RS-232C:SG, RS-485)500 V DC/1 min.Power supply terminal/input terminal,COM, EXC (0 V), case, comparativeoutput, 1500 V AC/1 min.Power supply terminal/COM of eachoutput (BCD:D.COM, ANALOG:-, RS-232C:SG, RS-485) 1500 V AC/1 min.
Insulation resistance: 500 V DC more than 100 MΩ at theabove terminals
Dielectric noise: Power supply terminalnormal/common mode ±1500 V
Power supply for sensor: 24 V DC±10% 40 mA ripple 100 mVp-pAccessories: Instruction manual
quick manual, setting list, unit label,terminal cover
High high limit set value Measured valueHigh limit set value Measured valueHigh high limit set value Low low limit set value
Measured value High limit set value Low limit set valueMeasured value Low limit set valueMeasured value Low low limit set value
HHHI
GO
LOLL
Comparison condition Comparisonresult
DC Voltage Measurement
Accuracy: ±(0.03% of rdg + 2 digit)(23°C±5°C 45 to 75% RH)
DC Current Measurement
Accuracy: ±(0.1% of rdg +2 digit)(23°C±5°C 45 to 75% RH)±(0.3% rdg +2 digit) for 25 range
General specifications Measurement blockInput configuration: Single endedOperation method: Dual slopeConversion rate: 12.5 time/sec (50 Hz), 15 time/sec (60 Hz)Noise rejection ratio: NMR more than 50 dB (50/60 Hz)Temp. coefficient: ±(0.005% of rdg +0.3 digit)/°CDisplay: Red LED, 14.2 mm height
Green LED, 8 mm height for setpointPolarity display: Automatic "–" display when the computation
result is minusOverrange warning: When input exceeds the maximum display,
display 0L or –0LMaximum display: 0 to ±9999 (4 digit)Decimal poin: Settable to any digit position (by front sheet
switch)Zero display: Leading zero suppression
External control blockHold: Shorted COM terminal and S/H terminal or level "0"Start: Shorted COM terminal and S/H terminal or level "1"Digital zero: Shorted COM terminal and DZ terminal or level "0"
(displayed zero and that value is stored)Peak holdValley hold: Shorted COM terminal and PH terminal or level "0"Peak Valley holdPattern selection: Any one of 8 patterns is settable in combination of
COM terminal and P.SEL terminal 0, 1 and 2Level "0" : 0 to 1.5VLevel "1" : 3.5 to 5 VInput current : less than -2 mA
Comparison blockControl method: Computation by microcomputerSetting range: -9999 to 0 to +9999 (Including polarity)Setting condition:
±9.999mA±99.99mA±999.9mA4 to 20mA
RangeInput InternalResistance
InputProtection
2324252A
DA
10Ω1Ω
0.1Ω10Ω
±150mA±500mA
±3A±150mA
Offset±9999Fullscale±0~9999
MeasuringRange
DisplayAdjustable
±99.9mV±999.9V±9.999V±99.99V±700.0V1 to 5V
RangeInput InputImpedance
InputProtection
1112131415IV
DV
100MΩ100MΩ1MΩ
10MΩ10MΩ1MΩ
±250V±250V±250V±500V±700V±250V
Offset±9999Fullscale±0 to 9999
MeasuringRange
DisplayAdjustable
SETPOINT COMPARATORAM-147
Features• Conversion rate 12.5times/sec(50Hz) or
15times/sec(60Hz)
• Four setpoint(Can display two setpoint)
• Maltiple range
• Scaling value and setting value stored 8 pattern
• Peak hold, Valley hold, Peak-valley hold, Digital zero,
Moving average(standard)
• Power supply for sensor 24VDC 40mA
• Direct setting function
• Power supply 90 to 264VAC
RS232C output
ASAHI KEIKI CO.,LTD.38
Com
para
tor
Output specifications BCD data output (isolated input (Lo))• At TTLMeasured data: Tri-stage parallel BCD, Positive logic, latch outputPolarity signal: Level "1" at minus inputOver signal: Level "1" at overflow inputPrinting command signal: Positive pulse approx. 20 ms at every
measurement completion (available negativelogic the above signals)
TTL level, funout 2, CMOS 5V
• At open collector (NPN)Measured data: Negative logic transistor "ON" at logic 1Polarity signal: Transistor "ON" at minus inputOver signal: Transistor "ON" at overflow inputPrinting command signal: Transistor "ON" during a period of approx. 20
ms at every measurement completionTransistor output capacity: Applied voltage, max. 30V current max. 10
mA saturated output voltage less than 1.2 Vat 10 mA
ENABLE: Shorted ENABLE terminal and D.COMterminal or level "0", Transistor output areOFF (TTL output is high impedance status)Level "0" : 0 to 1.5 VLevel "1" : 3.5 to 5 VInput current : less than - 2 mA
RS-485 (Isolated input (Lo))Electrical characteristics: Conforming to EIA RS-485Communication method: 2-wires system half-duplex (Polling and selecting)Transmission speed: 2400/4800/9600/19200 bpsStart bit: 1 bitData length: 7 bitsError detection: Even parity (BCC)Stop bit: 2 bitsCharacter code: ASCII codeTransmission control: No protocolSignal name used:
No. of connectable meter: Up to 31 metersLine length: Up to 500 m in total
RS-232C (Isolated input (Lo))Electrical characteristics: Conforming to EIA RS-232CCommunication method: Full duplexSynchronous method: Start and stopTransmission speed: 2400/4600/9600/19200 bpsStart bit: 1 bitData length: 7 bitsError detection: Even parityStop bit: 2 bitsCharacter code: ASCII code
Analog output (Isolated input (Lo))Resolution: 13 bitsOutput response: Less than 0.5S (0 to 90%)
* Ripple for 4 to 20 mA at resistive load 250Ω, 20 mA
Output Resistive load RippleAccuracy (23°C ± 5°C)0 to 10 V4 to 20 mA
50 mV P-PLess than 0.5%
More than 10 kΩ0 to 550Ω
±0.5% FS±0.5% FS
Signal name Signal Signal directionNon-reversible outputReversible output
Input/outputInput/output
+–
SETPOINT COMPARATORAM-147
Ordering Code
Dimensions
Connection Diagram
(A.OUT)0-10V4-20mA
Relay Output
RS-485
HH
OFF ON
TERMINATER
C
+ – (C) (C) (C) (C) (C)(e) (e) (e)
C LLHI GO LO
1 2 3 4 5 6 7 8 9 10
P.SEL
0
HI CLO ECOM
BA
1 2 P.H D.Z R.RE S/H 0V +24V
EXC
AC POWER
1
9
2 3 4 5 6 7 8
10 11 12 13 14 15 16 17
BCD OUT
2
1 4 1 4 1 4 1 4
1
2
8 2 8 2 8 2 8
34
33
NC NC
NCNC
PC
POL
NCNC NCOVER D.COM
D.COM
NCNC NC D.COM
D.COM
ENABLE101100 102 103
101100 102 103
13
SG
CT
SR
TS
RX
DT
XD
251
14
Upper
RS232C output
BCD output
Lower
Photo Coupler
HH HI HH
LO LLSET
ME
P.NO DZ RE
PH HH.LL
HI SETGO LO
S
96
48
ME
LL
92
Min120
Min
70
+0.8–0
45+
0.6
–0
148
144
7
127
MADE IN JAPAN
33
Panel thickness 0.8 to 5.0mm
Front
Side
Panel Cutout
AM-147-
Comparator Output
- -
Output
1. None2. BCD(Open collector)3. BCD(TTL)4. RS-4855. RS-232C6. ANALOG(4 to 20mA)7. ANALOG(0 to 10V)
InputRange
Power Supply 1. 90 to 264VAC
1. Relay2. Photo Coupler
DV(11,12,13,14,15,1V)
DA(23,24,25,2A)
39
Comparator
ASAHI KEIKI CO.,LTD.
SETPOINT COMPARATORAM-749
Comparison relay: 250 AC 0.2A Resistive load120V AC 0.5A Resistive load28V DC 1A Resistive load
Photo-coupler output: Sink current, 20mA max. (Less than30V)Output saturation voltage, Less than1.2V at 20mA
Hysteresis: Settable from 1 to 9999 digits foreach comparison set value
External Control: ResetContact capacity Comparison operation is suspended
when COM andr1R.RES terminals areshorted or input level is set at “0”.“0” level : Less than 1.5V“1” level : 3 to 30VInput current : Less than -5mA
Common specificationsMemory backup: Set data is stored for approx. 10
years by using EEPROM.Operating temperatureand humidity ranges: 0 to 50˚C
35 to 85% RHPower supply: 90 to 264V AC (50Hz / 60Hz)Power consumption: Appox. 5VA (st 100 AC)Dimensions: 48mm (H) x96mm (W) x161mm (D),
DIN sizeWeight: Approx. 600gDielectric Strength: 500V DC between input / earth E
and case 500V DC between inputterminal / common, digital common,sensor power supply and relayoutput 1500V AC between powersupply terminal / common, digitalcommon, sensor power supply,case and relay output.
Insulation resistance: More than 100MΩ at 500V DCbetween each terminal describedabove
Noise rejection: Power terminals, normal / commonmode, ±1500V square waveform for1ns at rise, noise, width, 500ns (BYnoise simulator)
Sensor power supply: 12V± 10% 80mARipple, Less than 200mVp-p
Accessory: Instruction manual
High high limit set-value Measured valueHigh limit set-value Measured valueHigh / high limit set-value Low / low limit set-value
Measured value High limit set-value Low limit set-valueMeasured value Low / lowlimit set-valueMeasured value Low limit set-value
HHHI
GO
LOLL
Comparison condition Comparison resultAM-749 DC Voltage Measurement
Accuracy: ± 0.03% rdg ±2 digit (23°C±5°C)
DC Current Measurement
Accuracy: ± 0.1% rdg ±2 digit (23°C±5°C)± 0.3% rdg ±2 digit only for 25 range
General specifications• Measurement blockMeasurement function: Specify one measuring range from DC voltage
and DC current measuring ranges.Input circuit: Single-endedOperation method: Dual slopeInput bias current: 100pA (TYP)Conversion rate: 12.5 times / sec (at 60Hz)
15 times / sec (at 50 / 60Hz)Noise rejection ratio: NMR-More than 50 dB (at 50 / 60Hz)Display: 7-segment LED (Light emitting diode numeric
element)Height, 10mm (red)Monitor / sub-display units-Height 8mm (green)
Polarity display: "-" is displayed when the computed result isnegative.
Overrange warning: "OL" LED (red) flashes when input signal exeedsmeasuring or display range.
Mximum display: ±99999 (5 digits)Decimal point: Settable at any position
(BY pressing sheets switch)Zero display: Reading "zero" suppression• External controlHold: Shorting between COM and S/H terminals or "0" levelStart: Open between COM and S/H terminals or "1" level
Value just before COM and DZ terminals are shortedDigital zero: or input level is set at "0" is displayed as "zero" and
that value is stored.Peak hold: Respective function is activated when COM andValley hold PH terminals are shorted or input level is set at "0".Peak valley hold:Pattern selection: Any one of 8 patterns is settable in combination of
COM terminal with any one of P SEL terminals 0, 1,and 2."0" level : less than 1.5V"1" level : 3V to 30VInput current :less than -5mA
• Comparioson blockControl method: Computaion by microcomputerMeasurinng range: High / Low limit setting including polarity, –99999 toComparison: 0 to +99999Setting condiotion: By sampling period
No setting restrictions for set-valueComparison condition:
±19.999mA±199.99mA±1.9999A4~20mA
RangeInput InputImpedance
Max allowableinput voltage
2324252A
DA
10Ω1Ω
0.1Ω10Ω
±150mA±500mA
±3A±150mA
Offset±19999Fullscale±0 to 19999
MeasuringRange
DisplayAdjustable
±199.99mV±1.9999V±19.999V±199.99V±700.0V
1~5V
RangeInput InputImpedance
Max allowableinput voltage
1112131415IV
DV
100MΩ100MΩ1MΩ
10MΩ10MΩ1MΩ
±250V±250V±250V±500V±700V±250V
Offset±19999Fullscale±0 to 19999
MeasuringRange
DisplayAdjustable
Features• Conversion Rate 12.5 times / sec (50Hz),
15 times / sec (60Hz).
• Peak, Valley, Peak-Valley Hold, Digital zero.
• Eight Pattern Setting (EEPROGRAM Back Up).
• Including Power Supply For Sensor 12V 80mA.
• Power Supply (AC90~264V).
• Direct Setting Function.
Four Setpoints
ASAHI KEIKI CO.,LTD.40
Com
para
tor
10 11 12 13 14 15 16 17
1 2 3 4 5 6 7 8
9
0 1 2 PH DZ R.RES S/H 0 12V
AB
CHI LO COM E AC POWER
P.SEL EXC
2 8 2 8 2 8 2 8
1 4 1 4 1 4 1 4
NC NC
NC NC
NC
NC
DG
DGPC
OVER
POL
ENABLEBCD output DG
DG
34
33
2
1
100 101 102 103
100 101 102 103
2 8
1 4
104
104
25 1413 1
SG RTS TXDCTS RXD
RS-232C
D-SUB Connector
① ② ③ ④ ⑤ ① ② ③ ④ ⑤
RS485 ANALOG output
NCNC SG+ - + - + - NC
1V~5V 4mA~20mA
TERMINATER
OFF ON
1 2 3 4 5 6 7 8 9 10
HH HI GO LO LLca acacacac
cecececece
(Relay outpuy)
(Photo coupler output)
SETPOINT COMPARATORAM-749
Dimensions
Connection Diagram
Connection Diagram
Front
Side
Panel Cutout
Upper
Lower
CONT
TZ PH DZ RE OL
HH HI GO LO LL
P R M S
96
48
153
1317
161
170
44.5
92
Min.120
Min
.70
+0.8-0
45+
0.6
-0
Ordering Code
AM-749
Data Output
- - -Comparator Output 1. Relay
2. Photo
1. None2. BCD (Open collector)3. RS-4854. RS-232C5. ANALOG
Power Supply 1.AC90V~264V
Range DV (11,12,13,14,15,1V)DA (23,24,25,2A)
Optional specifications•BCD output [Isolated from input(LO)]Measured date: Negative logic
NPN open-collector outputPolarity signal: Transistor "ON" at minus inputOVER signal: Transistor "ON" at "OVER" inputPrinting command signal: Transistor "ON" for approx. 10ms at the end of
measurementENABLE: All date output transistors are turned "OFF"
when ENABLE and digital common terminalsare shorted or input level is set at "0"."0" level:Less than 1.5V"1" level":3 to 30VInput current:Less than -5mA
Transistor output capacity: Applied voltage, 30V max. Current, 10mA max.Output saturation voltage:Less than 1.2V at10mA*TTL output is also available.
•RS-232C [Isolated from input(LO)]Electrical characteristics: Conforming to EIA RS-232CCommunication method: Full duplexSynchronous method: Start and stopTransmission speed: 2400/4800/9600/19200 bpsStart bit: 1 bitData length: 7 bitsError detection: Even parityStop bit: 2 bitsCharacter code: ASC IITransmission control: No protocol•RS-485 [Isolated from input(LO)]Electrical characteristics: Conforming to EIA RS-485Synchronous method: Start and stopCommunication method: 2-wire system half-duplex
(Polling and selecting)Transmission speed: 2400/4800/9600/19200 bpsStart bit: 1 bitDate length: 7 bitsError detection: Even parity
BCC(Block check character)check sumStop bit: 2 bitsCharacter code: ASC IITransmission control: No protocolSignal name used:
No. of connectable meters: Up to 31 metersLine length: Up to 500m in total
•Analog output [Isolated from input(LO)]Any display range to output analog signal can be set.Resolution: 16 bitsOutput response: Less 0.5s
Moving average: Digital filter functionFixed zero: 100 -digit is fixed to "0" for displayDisplay blanking: Blanking of LEDs on main, monitor/sub-display
units.Tracking zero: (Only for RS-232C and RS-485 meters)
Zero-point shift is digitally, automaticallycorrected. Activated when digital zero functionbecomes valid.
Panel thickness 0.8 to 5.0mmSignal name Signal Signal direction
Non-reversible outputReversible output
+–
Input/outputInput/output
Output Resistive load Accuracy (23˚C ±5˚C)
1 to 5V4 to 20mA
More than 10kΩ0 to 600Ω
±0.5% F.S±0.5% F.S
Ripple
50mVp-p–
ASAHI KEIKI CO.,LTD. 41
ComparatorSETPOINT COMPARATOR
AMH-752
4000 Time/sec Features
•Conversion Rate 1000/sec~4000/sec
•2 input computation(A, B)
•4-sets/4-pattern Setting
•Peak, Valley, Peak-Valley hold(Option)
•Digital zero(Option)
•RS-232C Communication(Option)
•BCD, ANALOG Output(Option)
•Bright LED 10mm(Red)
DC Voltage Measurement
Specifications1.Measuring function: Specify one type from among DC voltage, DC
current and instrumentation input signalmeasurements.
2.Operation method: Successive approximation type3.No. of input points: 2(A ch. and B ch.)ch./channel*4.Input selection: A, B, A+B, A-B, A & B, and (A-B)/ |B| 1005.Input circuit: Single-ended type6.Input bias current: 1nA(TYP)*7.Conversion Rate: 1.25 times/sec to 4000 times/sec(For 1 ch.)
0.652 times/sec to 2000 times/sec(For 2 ch.)8.Display: LED
Measured-value display unit characterheight;10.0mm(red)Monitor character height ; 8mm(green)
9.Display speed: 12.5 times/sec(Only in the normal speed mode)Display in the high-speed mode ; Displayed onlyduring hold.
±199.9mV±1.999V±19.99V±199.9V
Model RangeInput
ImpedanceInput
Protection
AMH-752-11AMH-752-12AMH-752-13AMH-752-14
100MΩ
10MΩ
±250V
±500V
OFFSET±1999
FULLSCALE±1999
DisplayAdjustable
Accuracy: ±0.1% ±2 digit(23°C±5°C)(a1)(Normal Speed Mode)±0.1% ±4 digit(23°C±5°C)(a1)(High Speed Mode)
DC Current Measurement
±199.9µA±1.999mA±19.99mA±199.9mA±1.999A
Model RangeInternal
ResistanceInput
Protection
AMH-752-21AMH-752-22AMH-752-23AMH-752-24AMH-752-25
OFFSET±1999
FULLSCALE±1999
1kΩ100Ω10Ω1Ω
0.1Ω
±10mA±50mA
±150mA±500mA
±3A
DisplayAdjustable
Accuracy: ±0.2% rdg. ±2 digit(23°C±5°C)(a1)±0.3% rdg. ±2 digit only for AMH-75X-25±0.2% rdg. ±4 digit(23°C±5°C)(a1) ±0.3% rdg. ±4 digit only for AMH-75X-25
Normal Speed Mode
High Speed Mode
1-5V Measuement
OFFSET ±1999
FULLSCALE ±1999
Model RangeInput
ImpedanceInput
Protection
AMH-752-1V 1-5V 1MΩ ±250V
DisplayAdjustable
Accuracy: ±0.1% rdg. ±3digit (23°C±5°C) (a1) (Normal Speed Mode)±0.1% rdg. ±5digit (23°C±5°C) (a1) (High Speed Mode)
4-20mA Measurement
OFFSET ±1999
FULLSCALE ±1999
Model RangeInput
ResistanceInput
Protection
AMH-752-2A 4-20mA 10Ω ±150mA
DisplayAdjustable
Accuracy: ±0.1% ±3 digit (23°C±5°C) (a1) (Normal Speed Mode)±0.1% ±5 digit (23°C±5°C) (a1) (High Speed Mode)
*a=Scaling Coefficient
Mode High Speed Mode
Conversion Rate(1ch) per sec.Conversion Rate(2ch) per sec.
4000(1)
2000
1 2 3 4No.2000(2)
1000
1333.3(3)
666.7
1000(4)
500
Mode Normal Speed Mode
Conversion Rate(1ch) per sec.Conversion Rate(2ch) per sec.
1000(5)
500
5No.500(10)
250
6250(20)
125
7125(40)
62.5
8100(50)
50
950
(100)
25
10
Mode Normal Speed Mode
Conversion Rate(1ch) per sec.Conversion Rate(2ch) per sec.
25(200)
12.5
11No.12.5(400)
6.25
1210
(500)
5
135
(1000)
2.5
142.5
(2000)
1.25
151.25
(4000)
0.625
16
( )Average time
10.Polarity display: Automatic "_" display when thecomputation result is minus
11.Overrange warning: Overflow display when input signalexceeds measuring rangeLED(red)flashes.(Display:Value justbefore overflow occurs)
12.Zero display: Leading "zero" suppression13.Decimal point: Settabel to any position(by dip switch at
the front).14.Maximum display: ±199915.External control: Start/hold(start hold A type)
Start/Start terminal open(or 5 V)Hold/Shorting between digital common
and hold terminals(or 0 V)*:Sample hold(start hold B type)Only one measurement is performed fromrise of positive or negative pulse of morethan 500µ s and the result is out-put.*:Digital zeroFunction of making the mechanical initialvalue such as of pressure sensor,potentiometer, etc. to zero electrically. By shorting betweenthe digital common and digital zero(for A ch. or B ch.) terminals, or at 0V;The displayed valuejust after the above shorting made orvoltage is set to 0 V is changed to "zero"and the value at that time is stored. (A ch. and B ch. can be independentlycontrolled.)*:Peak hold, valley hold and peak valleyhold•Peak hold Display of maximum valuemeasured•Valley hold;Display of minimum valuemeasured•Peak valley hold;Display of the difference betweenmaximum and minimum value measuredThe respective display function workswith the common and above terminalsshorted or at 0 V. (However, only display is made, andcomparison output is always inaccordance with voltage or current valueapplied between input Hi and Lo.)*:Settable on the sheet key at the front.
ASAHI KEIKI CO.,LTD.42
Com
para
tor
SETPOINT COMPARATOR
Ordering Code
Optional Specifications1.BCD output: Tri-state, Parallel BCD output, Fan out 2(TTL level) Polarity output/At minus value;"1"
Overflow output/At overflow;"1"P.C output;At the end of A/D conversion,plus pulse in approx. 500µs width*Only in the normal speed mode
2.RS-232C: Bidirectional(Full duplex)(Conformance)3.Analog output: Output voltage;±0 to 2.5V
Resolution;0.25mV/digitAccuracy;0.5% FS(23˚C±5˚C)External resistance;More than 20kΩOvervoltage;Approx.±3.5V, less than 5V*Any of high speed and normal speedmodes is available.
4.Absolute value display comparison:Function of outputting absolute valueregardless input single polarity
AMH-752
Output
- - -ComparesOutput
1. Relay Output (0.625Hz~80Hz)2. Photo Coupler Output (0.625Hz~4kHz)
1. None2. BCD3. ANALOG4. BCD,ANALOGR. RS-232C
PowerSupply
1. AC90~132V2. AC180~264V11
14Range21
25
1V
2A
~ ~
Comparison Section
Common Specifications1.Memory backup: Set data can be reserved for about 10 years
using EEPROM.2.Operating temperature and humidity:
0 to 50˚C, 35 to 85% RH3.Power supply: 90 to 132V AC 50/l60Hz
180 to 264V AC 50/60Hz(Internal jumper wire selection)
4.Power consumption: Approx. 5VA(at 100V)5.Dimensins: 48mm(H) 96mm(W) 158mm(D), DIN size6.Dielectric strength: Between input and grounding(E)terminals,
500V DCBetween input and digital common/relayoutput/transistors output;500V DC,eachBetween power supply terminal and inputterminal/grounding(E)/digital common/relayoutput/transistor outpu;1 min at 1500V AC,each.
7.Insulation resistance: Between each terminal described above, morethan 100MΩ at 500V DC
8.Weight: Approx. 600g(mainframe)9.Accessories: Input/output screw terminals, 2 pcs.
Instruction manualData output plug(Amphenol 57-30360)
10.Others: For unit display, contact us.
1.Control method: Computation by microcomputer2.Setting range: High/low limit setting including polarity(2/4-
step setting)-1999 to 0 to +1999
3.Comparison conditions (display):
4.Comparison display: As a comparison result, the respective lightemitting diode lights.
5.Comparison relay output:HH, HI, GO, LO, and LL(1 "a", each)
6.Relay output cycle: Approx. 12.5msConversion Rate: When the speed is slower
than 80 times /sec, output foreach sampling.
Conversion Rate: When the speed is fasterthan 80 times/sec, outputsthe result at that time atabout 12.5 msecintervals.(Excluded atstart/hold.)
7.Relay contact capacity: 250V AC, 0.1A Resistive load120V AC, 0.5A Resistive load28V DC, 1A Resistive load
8.Photo-Coupler output: Sink current;20mA max.(less than 30 V)(NPN open-collector)
9.Photo-Coupler output cycle:Approx. 250µs at the sampling speed of 4000times/sec for 1ch. inputFor others;Depending on each samplingspeed
10.Hysteresis: Settable from 1 to 999 digits for eachcomparison set-value.
11.External control: Comparison output reset with the reset anddigital common terminals shotred(or at 0 V)
At 1ch. input
AMH-752HH (HI)
HI
GO
LO
(LO) LL
Comparison resultComparison condition
Measured value>High/high limit set-valueHigh/high limit set-value≧Measured-value
>High limit set-valueHigh limit set-value≧Measured-value
≧Low limit set-valueLow limit set-value<Measured-value
≧Low/low limit set-valueLow/low limit set-value>Measured-value
AMH-752
ASAHI KEIKI CO.,LTD. 43
ComparatorSETPOINT COMPARATOR
AMH-752 Data Output
1 2 3 4 5 6 7 8
1 2 4 8 1 2 4 8
1 2 4 8 81 2 4
9 10 11 12 13 14 15 16 17 18
19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36
101 103
100 102
BCD OUTPUT ANALOG
BCD OUTPUT
Control Control
POLOVER
PC RTS CTS
RXDP.H TXD
SG
SG 0
D.COM
D.COM
P.SEL
P.SEL
RS-232C
RS-232C
1
ENABLED.Z.(B)D.Z.(A)
D. COM
A.OUT
A.OUT COM
25 1413 1
SG RTS TXDCTS RXD
D-SUB Connector
Dimensions
Connection Diagram
1587
※
92
Min.120
Min
.70
+0.8-0
45+
0.6
-0
HH
Relay Output
Relay Coupler Output
(UPPER) c=Common a= a Contact
(UPPER) e= Emitter c= Collector
HI GO LO LL
① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ ⑩
ac c a c a c a c a
HH HI GO LO LL
ce e c e c e c e c
① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ ⑩
INPUT
(LOWER)
Control E POWER
① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ ⑩
A.GAch Bch A.G COM S/H RESET
5min 3.6max
φ3.2min
5.9max
Upper
Lower
Front
Side
Panel Cutout
Panel thickness 0.8 to 5.0mm
TZ PH DZ RE
HH HI GO LO LL
OVEHS
SPM
96
48
ASAHI KEIKI CO.,LTD.44
Com
para
tor
SETPOINT COMPARATORAMH-762
High Conversion rate1000times/sec (Normal speed mode)4000times/sec (High speed mode)
Features
• High Conversion Rate, 1000times/sec (Normal speed mode)
4000times/sec (High speed mode)
• 2 inputs computation (A input, B input)
• Digital Zero, Peak Hold, Valley Hold, Peak-Valley Hold
• Available 8-pattern Setting for Scaling value and setpoints
(Data Back-up EEPROM)
•Excitation Supply 24VDC 40mA
•RS-232C, RS-485 Output (Option)
•BCD, Analog Output (Option)
•Power Supply (90 to 264VAC)
•Bright LED, 10mm (Red) DC Voltage Measurement
Specifications• Measuring SectionInput Configuration: Single EndedOperation Method: Successive approximation typeNo. of Input: A input and B inputConversion Rate : 0.5times to 4000times(only use one input)
0.25times to 2000times(use two input)
Range Display Adjustment Input Impedance Input ProtectioModel
AMH-762-13 ±9.999V 1MΩ ±250V
Accuracy:±0.1% FS (23°C±5°C)
Offset ±10000Fullscale ±0 to 10000
1 to 5V Measurement
Range Display Adjustment Input ImpedanceModel
AMH-762-1V 1 to 5V 1MΩ
Accuracy:±0.1% FS (23°C±5°C)
Offset ±10000Fullscale ±0 to 10000
Input Protectio
±250V
4 to 20mA Measurement
Range Display Adjustment Internal ResistanceModel
Offset ±10000Fullscale ±0 to 10000
AMH-762-2A 4 to 20mA 50Ω
Input Protectio
±70mA
Accuracy:±0.1% FS (23°C±5°C)
※Condition for accuracy, (FSC-OFS)/(FIN-OIN) is less than 1
Display: LED,10mm hight (Red)8mm hight (Green) for monitor
Display Speed: 1.25, 2.5, 12.5, 25times/sec forNormal speed modeWhen pressed key of "C", appeardisplay value for High speed mode
Polarity : A "-" is displayed automaticallyOverrange Indication: When input exceeds the maximum
display, display OL and flashMax. Display: ±99999Decimal Point: Settable to any digit positionZero Display: Leading zero suppressionEXternal Control: Hold ; Shorted D.COM and S/HA,
S/HBterminal or level "0" Start; Open D.COM and S/HA, S/HBterminal or "1" levelDigital Zero; Shorted D.COM andDZA, DZB terminal or level "0"Peak Hold; Valley Hold; Shorted D.COM and PHterminal or level "0"Peak Valley Hold;(Compare the
display value)Selected either one
Pattern Select; Combination ofD.COM and P.SEL terminal
Level "0"= 0 to +1.5VLevel "1"= +3.5 to 5VCurrent= less than -5mA Not provided PH, DZA and DZB forRS-232C and RS-485 output
High Speed Mode
Conversion Rate(1ch) per sec.
Conversion Rate(2ch) per sec. 2000
4000
1
1000
2000
2ModeNo.
Nomal Speed Mode
Conversion Rate(1ch) per sec.
Conversion Rate(2ch) per sec. 500
1000
4
500
250
8
400
200
10
200
100
20
100
50
40
50
25
80
40
20
100ModeNo.
Mode Nomal Speed Mode
Conversion Rate(1ch) per sec.
Conversion Rate(2ch) per sec.
No.
10
20
200
10
5
400
5
2.5
800
4
2
1000
2
1
2000
0.5
0.25
8000
1
0.5
4000
ASAHI KEIKI CO.,LTD. 45
ComparatorSETPOINT COMPARATOR
AMH-762• Comparator SectionControl System: MicrocomputerSetting Range: -99999 to +99999 with polarity Comparative Condition: High High setpoint < Indication /HH
High setpoint < Indication /HIHigh setpointIndicationLow setpointHigh high setpointIndicationLow low /GO
setpointLow setpoint > Indication /LOLow low setpoint > Indication /LL
Relay Contact Capacity: 250VAC 0.2A Resistive load120VAC 0.5A Resistive load28VDC 1A Resistive load
Photo Coupler Outpu: Voltage=Max. 30VCurrent=Max. 20mASaturation voltage=less than 1.2V at 20mA
Hysteresis: 1 to 9999 digit each setpointsExternal Control: Reset; Shorted D.COM and R.RE terminal or
level "0"
• Common SectionMemory Back-up : EEPROM (Rewrite more than 100,000 times)
back up 10 yearsOperating Temp: 0 to 50°C 35 to 85% RH Power Supply: 90 to 264VACPower Consumption: Approx 10VA TYP. (at 100V)Dimensions: 48(H) 96(W) 161(D) mm DIN sizeWeight: Approx. 600g (unit only)Dielectric Strength: Input/earth, COM, Comparative output,
DC500V/ 1 min.Input/D.COM of each output terminal,DC500V/1 min.Power supply/D.COM, case, comparativeoutput, 1500VAC/1 min.
Insulation Resistance: 500VDC more than 100M ohms at the aboveterminals
Excitation Supply: 24VDC ±10% 40mA (Ripple less than 100mVp-p)
Accessories: Instruction manual
Output BCD data output (Isolated input (Lo))
•At Open collector (NPN)Measured Data: Negative logic transistor "ON" at logic 1Polarity Signal: Transistor "ON" at minus inputOver Signal: Transistor "ON" at overflow input Printing Command Signal:
Transistor "ON" during a period at everymeasurement completion
Transistor Output Capacity:Applied voltage, 30V max. current 10mA max.Saturated output voltage less than 1.2V at10mA*Available TTL output
RS-485 (Isolated input (Lo))Electrical Characterstics: Conforming to EIA RS-485Synchronous Method: Start and stopCommunication Method: 2-wires system half-duplex (Polling and
selecting)Transmission Speed: 2400/4800/9600/19200 bPSStart Bit: 1 bitData Length: 7 bitsError Detection: Even parity (BCC)Stop Bit: 2 bitsCharacter Code: ASCII codeTransmission Control: No protocolSignal name used:
No. of Connectable Meter: Up to 31 metersLine Length: Up to 500m in total
RS-232C (Isolated input (Lo))Electrical Characterstics: Conforming to EIA RS-485Communication Method: Full duplexSynchronous Method: Start and StopTransmission Speed: 2400/4600/9600/19200 bpsStart Bit: 1 bitData Length : 7 bitsError Detection: Even parityStop Bit: 2 bitsCharacter Code: ASCII codeTransmission Control: No protocol
Analog Output (Isolated input (Lo))
Other FunctionsMoving Average: Digital Filter functionFixed Zero: 10˚digit is fixed to "0" for displayDisplay Blanking: Blanking of LEDs on main and
monitor displayTracking Zero: Zero point shift is digitally,
automatically corrected.Activated when digital zero functionbecomes valid
Resistive load Accuracy(23°C±5°C)Output
1 to 5V More than 10KΩ ±0.5% FS
4 to 20mA 0 to 500Ω ±0.5% FS
Signal Signal DirectionSignal name
Non-reversible output + Input/output
Reversible output – Input/output
ASAHI KEIKI CO.,LTD.46
Com
para
tor
SETPOINT COMPARATORAMH-762
Connection Diagram
Connection Diagram
Connector
Upper
Lower
GO LO LLHIHH
① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ ⑩
a (c)c (e) c (e) a (c) c (e) a (c) c (e) a (c) c (e) a (c)
( ):PHOTO COUPLER
EXCP.SEL
HI LOA.B chA.A ch
V.B chV.A ch
INPUT
E AC POWER
① ② ③ ④ ⑤ ⑥ ⑦ ⑧
⑨ ⑩ ⑪ ⑫ ⑬ ⑭ ⑮ ⑯ ⑰
10 2 D.COM S/HA S/HB R.RE 0V +24V
90V~264V
Front
Side
Panel Cutout
Panel thickness:0.8 to 5.0mm
CONT
TZ PH DZ RE OL
HH HI GO LO LL
HS
P R M S
96
48
153
1317
161
17044.5
92
Min.120
Min
.70
+0.8-0
45+
0.6
-0
Dimensions
Ordering Code
AMH-762- VA - -
Comparator Output 1. Relay 2. Photo Coupler
1. None 2. TTL3. Open Collector
BCD Output
1. None 2. BCD3. RS-4854. RS-232C5. Analog Output (1 to 5V 4 to 20mA)
Output
Range
Power Supply 1. 90 to 264VAC
DZACLR NC
DZB NC
NC NCNC
NCNC
PHNC NCNC NC NC NC NC NCNC
NC NCNC NC NCNC NC NC NC NC NCNC
D.COM
D.COM
34
33
2
1
2 8 2 8 2 8 2 8
1 4 1 4 1 4 1 4
NC
DZBNC NC
DZACLROVER
POL PC
ENABLE 1
ENABLE 2
PH
34
33
2
1
100 101 102 103
100 101 102 103
2 8
1 4
104
104
COM
COM
DZH NCPHCLR
4ー20mA
4ー20mA
1ー5V
1ー5V
COM
DZB NC COM
34
33
2
1
NCNC NC NC NC NC NC NCNCNC
NCNC+ + ー
+ ー
ー
+ ー
NC NCNC NC NC NC
25 1413 1
SG RTS TXDCTS RXD
D-SUB
NCNC SG+ - TERMINATER
OFF ONRS485output
RS232Coutput
Analog output
Output Connector
ASAHI KEIKI CO.,LTD. 47
ACV
&A
Ordering Code
Dimensions
Connection Diagram
AC Voltage Measurement
Accucracy: ±(0.3% of rdg. + 3 digit) (23°C ± 5°C, 35 ~ 85%RH)
AC Current Measurement
Accucracy: ±(0.5% of rdg. + 3 digit) (23°C ± 5°C, 35 ~ 85%RH)
SpecificationsInput Configuration: Single Ended input Impedance 10MΩ 100PF
or lessRectifier Circuit: Represents effective Value of sine wave by
demodulation of mean ValueConversion Rate: 2.5/secResponse Speed: Approx. 2.5sec(10~90%)Display: LED, 14.2mm 4 digitDecimal Point: Settable to any digit positionsOverrange Indication: When input exceeds the maximum display,
flash displayExternal Control: Hold; HOLD terminal and COM shortedPower Supply: AC90~132V
AC180~264VOperating Temperature: 0~50°C, 35 to 85%RHPower Consumtion: Approx. 2VADimensions: 48(H) × 96(W) × 95(D)mm DIN SizeWeight: Approx. 270gDielectric Strength: Between input terminal and earth(E),
DC500V/1 min. Between power supplyterminal and input terminal, COM, earth(E)AC1500V/1 min.
Insulation Resistance: DC500V 100MΩ at above terminals
AC VOLTMETER & AMMETERAP-166
AP-166-
Power Supply 1. AC90~132V2. AC180~264V
Range 12
15
~ 22
25
~
-
48
96
① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ HI LO NC
INPUT
COM HOLD NC EAC POWER
Features
• Average
• Bright LED 14.2mm (Red)
• AC 999.9mV~700.0V, AC 999.9mA~999.9mA
Measurement
Standard Type
FrequencyRange
999.9mV9.999V99.99V700.0V
Model RangeInput
ImpedanceInput
Protection
AP-166-12AP-166-13AP-166-14AP-166-15
10MΩ10MΩ10MΩ10MΩ
100V100V300V700V
40Hz~10kHz40Hz~10kHz40Hz~4kHz40Hz~1kHz
FrequencyRange
999.9µA9.999mA99.99mA999.9mA
Model RangeInternal
ResistanceInput
Protection
AP-166-22AP-166-23AP-166-24AP-166-25
1kΩ100Ω10Ω1Ω
10mA50mA200mA
1A
40Hz~1kHz40Hz~1kHz40Hz~1kHz40Hz~1kHz
7195
6.5
92
Min.120M
in.7
0
+0.8-0
45+
0.6
-0
Front
Side
Panel cut
Panel thickness 0.8 to 5.0mm
Upper
ASAHI KEIKI CO.,LTD.48
ACV
&A
AC VoltmeterAP-560
SpecificationsConversion Rate: 2.5/secOverrange Indication: noneDisplay: 3 digit, 14.2 mm Red LEDPower Consumption: 35 mA (MAX)Operating Temp.: 0 to 50˚C 35 to 85%RHDimensions: 96(W) 48(H) 22(D)mm DIN sizeWeight: Approx. 55 gDielectric Strength: input terminal/case, 1500 V DC/1 minInsulation Resistance: input terminal/case, more than 100 M ohm at
500 V DC
Features
•No need power supply
•Low cost
•Thin case, 1/8 DIN
Resolution
60 to 250 V AC240 to 600 V AC
Model Range Input Protection
AP-560-1AP-560-2
300 V700 V
1 V1 V
DC Voltage Measurement
Ordering Code
AP-560-1. 60 to 250 V AC2. 240 to 600 V AC
Dimensions
Connection Diagram
Front
Side
Panel cutout
48
96
12.26.3
92
Min.120
Min
.70
+0.8-0
45+
0.6
-0
AC INPUT
Panel thickness 0.8 to 3.2 mm
Accuracy : ± 3 digits (23°C ± 5°C 35 to 85%RH)
ASAHI KEIKI CO.,LTD. 49
ACV
&A
AC VOLTMETER & AMMETERA5-
SpecificationsDisplay: Main display Red LED 14.2 mm height
Sub display Green LED 8 mm heightConversion Rate: 12.5 times/sec.Maximum Display: 9999Overrange Indication: When input exceeds the maximum display,
display OL or –OLZero Display: Leading zero suppressionDecimal Point: Settable to any digit positionExternal Control: Start/Hold, Peak Hold, Digital ZeroOperating Temperature: 0 to 50°C 35 to 85% RHStorage Temperature: –10 to 70°C less than 60% RHPower Supply: AC 100 to 240V±10% (AC main unit)
DC 9 to 60 V (DC main unit)Power Consumption: Approx 4 VA (at 100 V)Dimensions: 96 mm × 48 mm (H) × 147.5 mm (D) DIN sizeWeight: Approx. 450 gDielectric Strength (AC): Power supply/input terminal/output terminal AC2000 V/1 min.
Input terminal/output terminal DC500 V/1 min.Case/power supply/input terminal output terminal AC2000 V/1 min.
Dielectric Strength (DC): Power supply/input terminal/output terminal DC500 V/1 min.Input terminal/output terminal DC500 V/1 min.Case/power supply/input terminal output terminal AC2000 V/1 min.
Insulation Resistance: DC500 V more than 100 MΩ at the above terminals
99.99 mV999.9 mV9.999 V
Range MeasurementRange DisplayInput Frequency Maximum
Resolution Input Impedance Input Protection Accuracy
111213
04 10 µV100 µV1 mV
more than 1 MΩ40 Hz to 1 kHz100 V100 V250 V
±(0.2% of rdg + 10 digit)±(0.2% of rdg + 10 digit)±(0.2% of rdg + 10 digit)
offset ±9999full scale 0 to ±9999
9.999 mA99.99 mA999.9 mA
Range MeasurementRange DisplayInput Frequency Maximum
Resolution Input Impedance Input Protection Accuracy
232425
08 1 µA10 µA100 µA
10 Ω1 Ω
0.1 Ω40 Hz to 1 kHz
100 mA500 mA
3 A
±(0.5% of rdg + 10 digit)±(0.5% of rdg + 10 digit)±(0.5% of rdg + 10 digit)
offset ±9999full scale 0 to ±9999
99.99 V600 V
Range MeasurementRange DisplayInput Frequency Maximum
Resolution Input Impedance Input Protection Accuracy
1415
05 10 mV100 mV
more than 1 MΩ40 Hz to 1 kHz250 V600 V
±(0.2% of rdg + 10 digit)±(0.3% of rdg + 10 digit)
offset ±9999full scale 0 to ±9999
5A
Range MeasurementRange DisplayInput Frequency Maximum
Resolution Input Impedance Input Protection Accuracy
2609
1 mA CT50 Hz or 60 Hz 8 A ±(0.5% of rdg + 10 digit)offset ±9999
full scale 0 to ±9999
Input configuration : Single endedResponse time : Approx. 1 sec.Crest factor : 4:1 at fullscale (only for TRUE-RMS)Dead zone : 0 to 99 digit
99.99 mV999.9 mV9.999 V
Range MeasurementRange DisplayInput Frequency Maximum
Resolution Input Impedance Input Protection Accuracy
111213
06 10 µV100 µV1 mV
more than 1 MΩ40 Hz to 1 kHz100 V100 V250 V
±(0.2% of rdg + 20 digit)±(0.2% of rdg + 20 digit)±(0.2% of rdg + 20 digit)
offset ±9999full scale 0 to ±9999
9.999 mA99.99 mA999.9 mA
Range MeasurementRange DisplayInput Frequency Maximum
Resolution Input Impedance Input Protection Accuracy
232425
10 1 µA10 µA100 µA
10 Ω1 Ω
0.1 Ω40 Hz to 1 kHz
100 mA500 mA
3 A
±(0.5% of rdg + 20 digit)±(0.5% of rdg + 20 digit)±(0.5% of rdg + 20 digit)
offset ±9999full scale 0 to ±9999
99.99 V600 V
Range MeasurementRange DisplayInput Frequency Maximum
Resolution Input Impedance Input Protection Accuracy
1415
07 10 mV100 mV
more than 1 MΩ40 Hz to 1 kHz250 V600 V
±(0.2% of rdg + 20 digit)±(0.3% of rdg + 20 digit)
offset ±9999full scale 0 to ±9999
5A
Range MeasurementRange DisplayInput Frequency Maximum
Resolution Input Impedance Input Protection Accuracy
2611
1 mA CT50 Hz or 60 Hz 8 A ±(0.5% of rdg + 20 digit)offset ±9999
full scale 0 to ±9999
AC Voltage, Current (TRUE-RMS)
AC Voltage, Current (Average)
Ordering Code
A5 -
Input
Output
Display board
Main board
0. None 1. HI & LO setpoint2. Analog output3. RS-232C 4. RS-4855. HI & LO setpoint + analog output6. HI & LO setpoint + analog output + RS-232C7. HI & LO setpoint + analog output + RS-485
1. Single 2. Multiple
1. AC100 - 240 V (±10%) 2. DC9 - 60 V
04. AC voltage AVG (99.99 mV to 9.999 V) 05. AC voltage AVG (99.99 V to 600 V)06. AC voltage RMS (99.99 mV to 9.999 V)07. AC voltage RMS (99.99 V to 600 V)08. AC current AVG (9.999 mA to 999.9 mA)09. AC current AVG (5 A)10. AC current RMS (9.999 mA to 999.9 mA)11. AC current RMS (5 A)
Features
•Low Cost
•Power Supply AC100~240 V
DC9~60 V
ASAHI KEIKI CO.,LTD.50
Proc
ess
Mon
itor
Ordering code
Dimensions
Connection Diagram
DC Voltage Measurement
DC Current Measurement
SpecificationsMeasurement function :DC voltage & current measurement.Front
Specify one model from among 4 models.Operation method : Dual slopeInput configuration : Single endedInput Bias Current : 2nA(Typ.)Conversion rate : 2.5 times/sec Normal mode rejection :More than 4dB (50/60Hz) (Typ.)Max.display : 1999Overrange indication : When input exceeds the maximum display,
1999 or -1999 flashesDisplay : LED, 14.2mm, 3 1/2-digitsPolarity : Automatic polarity selectionPolarity display : A “–” is displayed automaticallyExternal control : Hold;COM terminal and S/H terminal shorted Side
or level “0”Decimal point : Settable to any digit positionOperation Temperature/humidity : 0 ~ 50˚C, 35 to 85%RHStorage temperature/humidity : -10 ~ 70˚C, 60%RH max.Power supply : AC 90V~132V 50/60Hz 2.0VA(Max.) (100V)
180V~264V 50/60Hz 2.0VA(Max.) (200V)DC 24V ±20% 40mA(Max.) Isolated
Dimensions : 96mm(W) x 48mm(H) x 71mm(D) DIN sizeWeight : AC Approx. 175g DC Approx. 100gDielectric resistance : AC type; Between power supply and input
terminal(Lo),COM,case, AC2100V/1 min.DC type; Between power supply(0V) andinput(Lo), DC500V
Insulation resistance : Between power supply terminal(0) andinput(Lo) DC500V more than 100M ohm
Accessory : Instruction manual, terminal cover,2-axis,2-screwStandards : IEC1010-1,EN50082-2,EN50081-2Setup environment : Installation category II, Pollution degree 2Altitude : 2000m max.Fuse : Type TR-5 19372-0.2A Slow-blow type
DIGITAL SCALING METERAS-101
Features• Low Cost
• CE Approval
1~5V0~5V
0~10V
Offset ±10Fullscale 100~1999
1MΩ ±100VAS-101-1VAS-101-2VAS-101-3V
DisplayAdjustable
InputImpedance
InputProtection
Model Range
Accuracy : ±(0.1% of rdg. + 2 digits) (23°C ±5°C, 35~85%RH)
4~20mAOffset ±10Fullscale 100~1999
51Ω ±70mAAS-101-2A
DisplayAdjustable
InputImpedance
InputProtection
Model Range
Accuracy : ± (0.1% of rdg. + 2 digits) (23°C ±5°C, 35~85%RH)
Power supply
Range
1: AC 90~132V2: AC 180~264V4: DC 24V (Isolated)
1V: 1~5V2V: 0~5V3V: 0~10V2A: 4~20mA
AS-101- -
48
96
71566.5
92+0.8-0
45+
0.6
-0
Front
Side
Panel cut
① ② ③ ④ ⑤ ⑥ ⑦ ⑧
INPUT AC/DC POWER
HI LO NC S/H 0V +VCOM
NC
ASAHI KEIKI CO.,LTD. 51
ProcessM
onitor
Ordering Code
Dimensions
Connection Diagram
DC Voltage Measurement
Accuracy: 0.1% rdg. ±2 digits (23°C ±5°C)
DC Current Measurement
Accuracy: ±0.2% rdg. ±2 digits (23°C ±5°C)±0.3% rdg. ±1 digit only for AS-203A-25
1~5V Measurement
Accuracy: ±0.1% rdg. ±2 digits (23°C ±5°C)
4~20mA Measurement
Accuracy: ±0.1% rdg. ±2 digits (23°C ±5°C)
SpecificationsInput Configuration: Single EndedInput Bias Current: 2nA (Typ.)Conversion Rate: 2.5/secNormal Mode Rejection: 40dB (Typ.) (50/60Hz)Temperature Coefficient: Offset Typ. ±0.1, Max. ±0.3 digit/°C
Fullscale Typ. ±0.1, Max. ±0.3 digit/°CDisplay: LED, 8mm 3 1/2 digitsPolarity: A "-" is displayed automaticallyDecimal Point: Settable to any digit positionOverrange Indication: When input exceeds the maximum display,
1999 flashesFullscale Adjustment: 100~1999Offset Adjustment: ±1000Span: 2000 countsPower Supply: DC5V ±5%, 90mA (Typ.)
DC24V ±20%, 20mAOperating Temperature: 0~50°C, 35 to 85%RHPower Consumption: 450 mW at 5V, 480 mW at 24VDimensions: 24(H) × 48(W) × 73(D)mm DIN SizeWeight: Approx. 46gDielectric Strength: Between power supply (0V) terminal and input
(Lo) terminal, DC500VBetween input (Lo) terminal and mountingpanel, AC1500V/1 min.
Insulation Resistance: DC500V 100MΩ at above terminals
PROCESS MONITORAS-203A
AS-203A-Power Supply
-3. DC 5V (Isolated)4. DC 24V (Isolated)
11
14Range
~ 21
25
~ 1V
2A
~
5173
4.8
48
24
FullscaleAdjust
Offset Adjust
1 2
LOHI BL COM OV +5. 24V
PowerINPUT
Sta
rt/H
old
3 4 5 6 7 8 9 10
Features
• Easily adjustable offset-fullscale from the front panel
(Span 2000 counts)
• Bright LED, 8mm (Red)
• DIN size 24(H) × 48(W)mm
• Power supply DC5V or DC24V (Isolated)
• 200mV~200V, 200µA~2A Measurement
• 1~5V, 4~20mA Measurement
Miniature Size
±199.9mV±1.999V±19.99V±199.9V
Model RangeInput
ImpedanceInput
Protection
AS-203A-11AS-203A-12AS-203A-13AS-203A-14
Offset ±1000
Fullscale ±100~1999
100MΩ100MΩ10MΩ10MΩ
±100V±250V±250V±500V
DisplayAdjustable
±199.9µA±1.999mA±19.99mA±199.9mA±1.999A
Model RangeInternal
ResistanceInput
Protection
AS-203A-21AS-203A-22AS-203A-23AS-203A-24AS-203A-25
Offset ±1000
Fullscale ±100~1999
1kΩ100Ω10Ω1Ω
0.1Ω
±10mA±50mA
±150mA±500mA
±3A
DisplayAdjustable
1~5V
Model RangeInput
ImpedanceInput
Protection
AS-203A-1V Offset ±1000Fullscale 100~1999 1MΩ ±250V
DisplayAdjustable
Min.65
Min.3522.2
+0.3
-0
45+0.6 -0
Front
Side
Panel cut
Panel thickness 0.8 to 3.5mm
4~20mA
Model RangeInternal
ResistanceInput
Protection
AS-203A-2A Offset ±1000Fullscale 100~1999 51Ω ±70mA
DisplayAdjustable
ASAHI KEIKI CO.,LTD.52
Proc
ess
Mon
itor
Ordering Code
Dimensions
Connection Diagram
LOHIOV +5V
D.P
COM
Connect input Lo and Ov.
Power
INPUT
HO
LD
1 2 3 4 5 6 7 8 9 10
101 102 103
48
73
514.8
24
Fullscale Adjust
Offset Adjust
Min.65
Min
.3522
.2+
0.3
–0
45+0.6–0
Front
Panel thickness 0.8 to 3.2mm
Side
Panel Cutout
AS-201 -
1V2V3VRange
DC Voltage Measurement
Accuracy: ±0.1% rdg ±2 digit (23°C ±5°C)
SpecificationsInput Configuration: Single EndedInput Bias Current: 2nA(Typ.)Conversion Rate: 2.5/secNormal Mode Rejection: 40dB Typ. (50/60Hz)Temperature Coefficient: ±0.1 digit (Typ.)/°C
±0.3 digit (Max.)/°CDisplay: LED, 10.2mm 3 1/2 digitPolarity: 1V Range:When input less than 1V, a "-" is
displayed automatically.2V, 3V Range:When input less than 0V, a "-"is displayed automatically.
Decimal Point: Settable to any digit positionOverrange Indication: When input exceeds the maximum display,
1999 flashesFull-scale Adjustment: 100~1999External Hold: Negative 0V or ShortPower Supply: DC 5V±5% 70mA (Typ.)Operating Temperature: 0~50°C, 35 to 85%RHPower Consumption: 350mWDimensions: 24(H) 48(W) 73(D)mm DIN SizeWeight: 40gDielectric Strength: Between Input(Lo) and Mounted panel,
AC1500V/1 min.Insulation Resistance: DC500V 100MΩ or more at above terminals
1~5V0~5V
0~10V
Model Code RangeInput
ImpedanceInput
Protection
AS-201-1VAS-201-2VAS-201-3V
1MΩ1MΩ1MΩ
±250V±250V±250V
0-100~19990-100~19990-100~1999
DisplayAdjustable
PROCESS MONITORAS-201
Features• Adjustable full scale
• Bright LED 10.2mm
• Din size 24(H) 48(W)
• 1-5V, 0-5V, 0-10V measurement
• Power supply DC5V (NO-ISOLATED)
Fullscale Adjustable
ASAHI KEIKI CO.,LTD. 53
ProcessM
onitor
Dimensions
Connection Diagram
INPUT EARTH
Hi Lo (E)
DECIMAL POINT
103 102 101
96
48
Offset VR
Fullscale VR
2212.26.3
Min.120
Min.70
92 +0.8 -0
45+0.6
-0
Panel thickness 0.8~3.2mm
Front
Side
Panel Cutout
4~20mA Measurement
Accuracy: ±0.1% F.S. ±1 digit (23°C ±5°C)
SpecificationsInput Configuration: Single EndedMax. Display: 1999Conversion Rate: 2.5/secNormal Mode Rejection: NMR 40dB (TYP)Temperature Coeficient: Offset display, ±0.3 digit/°C (Max.)
Fullscale display,±0.3 digit/°C (Max.)Overrange Indication: When input exceeds the maximum display,
display +1 and blank other digitsFullscale Adjustment: 100 to 1999Offset Adjustment: ±200 digitsVoltage Drop: 2.2V (at 20mA) Typ.
1.6V (at 4mA) Typ.Display: LCD, 12.7mm Polarity: A "-" is displayed automaticallyDecimal Point: Settable to any digit positionPower Supply: Current loop power (4 to 20mA)Operating Temperature: 0 to 50 °C, 35 to 85% RHDimensions: 48(H) 96(W) 22(D)mm DIN sizeWeight: Approx. 55 g (unit only)Dielectric Strength: Input (Lo) terminal and earch(E),
500VDC/1min.Accessory: Instruction Manual
Ordering Code
AL-501A
4~20mA
Model RangeInput
Protection
AL-501A Offset ±200Fullscale 100~1999 ±50mA
DisplayAdjustable
PROCESS MONITORAL-501A
Features• Self power (4~20mA)
• Easily adjustable for offset-fullscale from the front panel
• LCD Display, 12.7 mm
• Screw terminals
• 4~20mA Measurement
Self Power(4 to 2omA)
ASAHI KEIKI CO.,LTD.54
Proc
ess
Mon
itor
PROCESS MONITORAL-213
SpecificationsInput Configuration: Single endedMax. display: 1999Conversion rate: 2.5/sec (TYP)Normal mode rejection: 40 dB (TYP)Temperature Coefficient: Offset display, ±0.3 digit/˚C
Fullscale display, ±0.3 digit/˚COverrange indication: When input exceeds the maximum display, display 1
and blank other digitsFullscale adjustment: 100-1999Offset adjustment: ±200Voltage drop: 5 V at 4 mA
5.3 V at 20 mADisplay: LED (red), 10.16 mmPolarity: A "-" is displayed automaticallyDecimal point: Settable to any digit positionOperating temp.: 0 -50˚C 35-85%RHDimensions: 48 (W) 24 (H) 40 (D) mm DIN sizeDielectric strength: Between input (LO) and earth (E) DC500 V/minWeight: approx. 55 g
Ordering codeAL-213
Features
•Self power (4-20mA)
•LED display 10.16mm (red)
•Screw terminal
Display4-20mARange Input ProtectionModel
AL-213
Accuracy: ± (0.1% of FS + 1 digit) (23 ± 5) 35-85%RH
± 50mAOffset ± 200Fullscale 100-1999
4-20mA Measurement Dimensions
Connection Diagram
Front
Side
24
48
10.16
4.3
57.7
39.7
Rear
45
65mm以上
35mm以上
+0.6-0
22.2+
0.3-
0
1 2 3
Panel thickness 0.8 to 3.2mm
Terminal No. 1 Input HI2 Input LO3 Earth
Panel cutout
ASAHI KEIKI CO.,LTD. 55
ProcessM
onitor
Dimensions
Connection Diagram
4~20mA Measurement
Accuracy: ±(0.1% of FS + 1 digit) (23°C ±5°C, 35 to 85% RH)
SpecificationsInput Configuration: Single endedMax. Display: 1999Conversion Rate: 2.5/secNormal Mode Rejection: NMR 40dB (TYP)Temperature Coeficient: Offset display, ±0.3 digit/°C
Fullscale display, ±0.3 digit/°COverrange Indication: When input exceeds the maximum display,
display 1 and blank other digitsFullscale Adjustment: 100 to 1999Offset Adjustment: ±200Voltage Drop: 5V at 4 mA
5.3V at 20 mADisplay: LED, 14.2 mm Polarity: A "-" is displayed automaticallyDecimal Point: Settable to any digit positionOperating Temp: 0 to 50°C, 35 to 85% RHDimensions: 96(W) × 48(H) × 22(D)mm DIN sizeWeight: Approx. 55 g (unit only)Dielectric Strength: Input (Lo) and earth(E), 500VDC/1 min.Accessory: Instruction Manual, terminal cover.
Ordering Code
AL-512
PROCESS MONITORAL-512
48
96
92
Min.120M
in.7
0
+0.8-0
45+
0.6
-0
Front
Side
Panel cut
INPUT EARTH
Hi Lo (E)
Features
• Self power (4~20mA)
• LED display 14.2 mm (red)
• Screw terminal
4~20mA
Model RangeInput
Protection
AL-512 Offset ±200Fullscale 100~1999 ±50mA
Display
22
12.26.3
Panel thickness 0.8 to 3.2mm
ASAHI KEIKI CO.,LTD.56
Ther
mom
eter
PROCESS MONITORAS-243
Standard 4 1/2 Digit
Dimensions
Connection Diagram
Front
Side
Panel Cutout
Panel thickness 0.8 to 3.5mm
24
48
87
655
45
Min.65
Min
.35
+0.6-0
22.2+
0.3
-0
1 2
LOHI NC NC NCNCCOMS/H - +
DC POWERINPUT
3 4 5 6 7 8 9 10
Features
•Easily adjustable offset-fullscale (Span 10000 counts)
•Bright LED, 8 mm (Red)
•DIN size 24 (H) 48 (W) mm
•Power supply DC 24 V (isolated)
•1-5 V, 0-5 V, 0-10 V, 4-20 mA measurement
DC Voltage Measurement
General SpecificationsInput configuration : Single endedInput bias current : 2 mA (TYP.)Conversion rate : 2.5/secNormal mode rejection : 50dB (TYP.) (50/60 Hz)Temp. coefficient : Offset display ±0.5 digit/˚C
Fullscale display ±0.01% of span/˚COverrange indication : When input exceeds the maximum display,
display flashesFullscale adjustment : 100 to 9999Offset a djustment : ±5000Span : 10000 countsDisplay : LED, 8 mm (Red)Polarity : A "-" is displayed automaticallyScaling : By switch (rear) and fine volume (front)Hold : COM and S/H terminal shortedDecimal point : Settable to any digit positionOperating temperature : 0 to 50˚C 35 to 85%RHPower supply : DC24V±20%Power consumption : 30 mA at DC24VDimensions : 24(H) 48(W) 87(D)mm DIN sizeWeight (unit) : Approx. 50gDielectric strength : Between input (Lo) and mounted panel, AC
1500V/l min.Between input (Lo) and power supply (0V), DC500 V/l min.
Insulation resistance : DC 500 V 100 MΩ or more at the aboveterminals
Accessory : Connector, Instruction manual
Model Range Display Input Impedance Input ProtectionAS-243-1V 1-5 V Offset ±5000 1MΩ ±250VAS-243-2V 0-5V fullscale 1MΩ ±250VAS-243-3V 0-10 V 100 to 9999 1MΩ ±250V
Accuracy: ±(0.1%of rdg+2 digit) (23˚C±5˚C 45~75%RH)
DC Current MeasurementModel Range Display Internal Resistance Input Protection
AS-243-2A 4-20mA Offset ±5000 50Ω ±50mAfullscale100 to 9999
Accuracy: ±(0.1% of rdg+2 digit) (23˚C±5˚C 45~75%RH)
Ordering Code
AS-243 4-
Power Supply
-
Range
4. DC24V
1V2V3V2A
ASAHI KEIKI CO.,LTD. 57
Thermom
eterTHERMOMETER
A5-
SpecificationsDisplay: Main display Red LED 14.2 mm height
Sub display Green LED 8 mm heightConversion Rate: 12.5 times/sec.Maximum Display: 9999Overrange Indication: When input exceeds the maximum display,
display OL or –OLZero Display: Leading zero suppressionDecimal Point: Settable to any digit positionExternal Control: Start/Hold, Peak Hold, Digital ZeroOperating Temperature: 0 to 50°C 35 to 85% RHStorage Temperature: –10 to 70°C less than 60% RHPower Supply: AC 100 to 240V±10% (AC main unit)
DC 9 to 60 V (DC main unit)Power Consumption: Approx 4 VA (at 100 V)Dimensions: 96 mm × 48 mm (H) × 147.5 mm (D) DIN sizeWeight: Approx. 450 gDielectric Strength (AC): Power supply/input terminal/output terminal AC2000 V/1 min.
Input terminal/output terminal DC500 V/1 min.Case/power supply/input terminal output terminal AC2000 V/1 min.
Dielectric Strength (DC): Power supply/input terminal/output terminal DC500 V/1 min.Input terminal/output terminal DC500 V/1 min.Case/power supply/input terminal output terminal AC2000 V/1 min.
Insulation Resistance: DC500 V more than 100 MΩ at the above terminals
KKJTSRB
Range SensorType
–50.0 to 199.9°C–50 to 1200°C–50 to 1000°C–50 to 400°C0 to 1700°C
–10 to 1700°C100 to 1800°C
MeasurementRange
MaximumResolution Accuracy
KAKBJTSRB
13
0.1°C1°C1°C1°C1°C1°C1°C
±(0.5% of FS)±(0.2% of FS)±(0.2% of FS)±(0.6% of FS)±(0.4% of FS)±(0.4% of FS)
±(0.4% of FS) over 500°Cavailable Fahrenheit display
Cold junction compensator accuracy : ±1°C (10 to 40°C)Sensor lead resistance : Less than 50 ΩLinearizing method : Digital linearizingBurn out alarm : ———
PT100 ΩPT100 Ω
Range SensorType
–100.0 to 199.9°C–100 to 600°C
MeasurementRange
MaximumResolution Accuracy
PAPB
14 0.1°C1°C
±(0.15% of FS)±(0.3% of FS)
available Fahrenheit displayCurrent for resistance : Approx. 1 mAExternal lead resistance : Less than 10 Ω/leadLinearizing method : Digital linearizingBurn out alarm : ———
RTD
Thermocouple Ordering Code
A5 -
Input
Output
Display board
Main board
0. None 1. HI & LO setpoint2. Analog output3. RS-232C 4. RS-4855. HI & LO setpoint + analog output6. HI & LO setpoint + analog output + RS-232C7. HI & LO setpoint + analog output + RS-485
1. Single 2. Multiple
1. AC100 - 240 V (±10%) 2. DC9 - 60 V
13. Temperature (Thermocouple) 14. Temperature (RTD)
Dimensions
92
96
487
121
45
147.
5
45+
0.6
-0
92 +0.8- 0
MIN
.70
MIN.120
Features
•Low Cost
•Power Supply AC100~264 V
DC9~60 V
•Sensor Type :K, J, T, S, R, B, PT100 Ω
ASAHI KEIKI CO.,LTD.58
Ther
mom
eter
Ordering Code
Dimensions
Connection Diagram
TC Measuring Range
RTD Measuring Range
SpecificationsInput Configuration: Single EndedConversion: 2.5/secNormal Mode Rejection: 40dB (Typ.)Display: LED, 8mm 3 1/2 digitPolarity: A "-" displayed automaticallyPower Supply: DC5V ±5% 90mA
DC12V ±20% 40mADC24V ±20% 20mA
Operating Temperature: 0~50°C, 35 to 85%RHDimensions: 24(H) × 48(W) × 66(D)mm DIN SizeWeight: Approx. 51gDielectric Strength: Between Input (A, B, COM) and 0V terminal,
DC500VInsulation Resistance: DC500V 100MΩ at above terminals
TC Measurement SectionSensor: K or JTemperature Display: °C or °FResolution: 1°C or 1°FExternal Lead Resistance: Less than 100ΩCold Junction Compensator Accuracy: ±2°C (10°C~40°C)Burn-out Alarm: -1999 FlashingExcessive Input: DC ±5V
RTD Measurement SectionSensor: PT-100ΩCurrent for Resistance: 1mA (Typ.)Temperature Display: °C or °FResolution: 0.1°C or 1°C, 1°FExternal Lead Resistance: Less than 1Ω/leadLinearizing Method: Analog Linearizing
Analog Output SectionVoltage: 1mV/°C or 1mV/°F, 10mV/°C for PAAccuracy: ±2% F.S. (23°C ±5°C)External Lead Resistance: More than 20kΩ
THERMOMETERAT-205
AT-205-Output
-
Code
3. DC5V (Isolated)4. DC24V (Isolated)5. DC12V (Isolated)
1. None3. Analog
Power Supply
PAPFPJ
KCJCKFJF
48
24
45
Min.65
Min
.35
+0.6-0
22.2+
0.3
-0
Front
Side
Panel cut
HOLDCOM
OUTT.C.
RTDPt
A B0V
ANALOG DC POWER5V/12V/24
① ② ③ ④ ⑤ ⑥ ⑦
+
Features
• Small Size
• Power Supply DC5V, DC12V, DC24V
• Sensor Types K, J, and PT-100Ω• Analog Output (option)
• Screw Terminal
• Bright LED, 8mm (Red)
Miniature Size
0°C~+1000°C+32°F~+1832°F
0°C~+400°C+32°F~+752°F
Sensor Measuring RangeAccuracy
(23°C±5°C)
K
J
1°C1°F1°C1°F
±0.8% F.S.±0.8% F.S.±0.8% F.S.±0.8% F.S.
Code
KCKFJCJF
Resolution
-100.0°C~+199.9°C-200°C~+600°C-328°F~+1112°F
Sensor Measuring RangeAccuracy
(23°C±5°C)
PT-100Ω0.1°C1°C1°F
±0.2% F.S.±0.4% F.S.±0.4% F.S.
Code
PAPJPF
Resolution
66
514.8
Panel thickness 0.8 to 3.5mm
ASAHI KEIKI CO.,LTD. 59
StrainG
augeSTRAIN GAUGE METER
A5-
SpecificationsDisplay: Main display Red LED 14.2 mm height
Sub display Green LED 8 mm heightConversion Rate: 12.5 times/sec.Maximum Display: 9999Overrange Indication: When input exceeds the maximum display,
display OL or –OLZero Display: Leading zero suppressionDecimal Point: Settable to any digit positionExternal Control: Start/Hold, Peak Hold, Digital ZeroOperating Temperature: 0 to 50°C 35 to 85% RHStorage Temperature: –10 to 70°C less than 60% RHPower Supply: AC 100 to 240V±10% (AC main unit)
DC 9 to 60 V (DC main unit)Power Consumption: Approx 4 VA (at 100 V)Dimensions: 96 mm × 48 mm (H) × 147.5 mm (D) DIN sizeWeight: Approx. 450 gDielectric Strength (AC): Power supply/input terminal/output terminal AC2000 V/1 min.
Input terminal/output terminal DC500 V/1 min.Case/power supply/input terminal output terminal AC2000 V/1 min.
Dielectric Strength (DC): Power supply/input terminal/output terminal DC500 V/1 min.Input terminal/output terminal DC500 V/1 min.Case/power supply/input terminal output terminal AC2000 V/1 min.
Insulation Resistance: DC500 V more than 100 MΩ at the above terminals
–0.3 to +2 mV/V
PowerSupply
for Sensor
ZeroAdjustment
Range
1 to 3 mV/V
SpanAdjustment
Range
MaximumResolution Accuracy
5 V10 V
170.5 µV/digit1 µV/digit
±(0.1% of FS) +2 digit
Sensor : 350 ΩPower supply for sensor : 5 V±5% (less than 15 mA)
10 V±5% (less than 30 mA)
HIGOLO
Setting range : –9999 to 9999Hysteresis : 1 to 999 digit for each setpointsRelay contact capacity : AC240 V 8 A resistive load
DC30 V 8 A resistive load
Indication > High setpointHigh setpoint Indication Lo setpointIndication < Lo setpoint
Output
HI & LO setpoint output (A5XX1-XX)
±(0.5% of FS)
Output method : PWM methodScaling : Digital scaling
0 to 1 V0 to 10 V1 to 5 V
4 to 20 mA
more than 10 kΩmore than 10 kΩmore than 10 kΩless than 550 Ω
Output Resistive load Accuracy
Analog output (A5XX2-XX)
Communication method : Full duplexTransmission speed : 2400/4800/9600/19200/38400 bpsStart bit : 1 bitData length : 7 bit/8 bitParity : Even parity/odd parityStop bit : 1 bit/2 bitCharacter code : ASCII codeTransmission control process : lgnored process
RS-232C (Conforming to EIA RS-232C) (A5XX3-XX)
Communication method : Full duplexTransmission speed : 2400/4800/9600/19200/38400 bpsStart bit : 1 bitData length : 7 bit/8 bitParity : Even parity/odd parityError detection : BCCStop bit : 1 bit/2 bitCharacter code : ASCII codeTransmission control process : lgnored processSignal name : + non reversal output
– reversal outputMaximum No. of meter connected : 31Line length : Up to 500 m in total
RS-485 (Conforming to EIA RS-485) (A5XX4-XX)
Strain Gauge
Ordering Code
A5 -
Input
Output
Display board
Main board
0. None 1. HI & LO setpoint2. Analog output3. RS-232C 4. RS-4855. HI & LO setpoint + analog output6. HI & LO setpoint + analog output + RS-232C7. HI & LO setpoint + analog output + RS-485
1. Single 2. Multiple
1. AC100 - 240 V (±10%) 2. DC9 - 60 V
1 7
Dimensions
92
96
487
121
45
147.
5
45+
0.6
-0
92 +0.8- 0
MIN
.70
MIN.120
ASAHI KEIKI CO.,LTD.60
Stra
inG
auge
Dimensions
Connection Diagram
SpecificationsAccuracy: 0.1%FS ±1 digitConversion Rate: 2.5/secNormal Mode Rejection: NMR 40dB (Typ) (50/60Hz)Sensor: Strain gauge sensor (350W)Excitation Supply: DC5V±5% 20mADisplay: LED, 8mm (RED)Decimal Point: Settable to any digit positionOverrange Indication: When input exceeds the maximum display,
1999 flashesPower Supply: DC19 to 29V (40mA at DC24V)Operating Temperature: 0 ~ 50°C, 30 ~ 85%RHPower Consumption: Approx. 1WDimensions: 24(H) × 48(W) × 87(D) mm DIN SizeWeight: Approx. 53g (unit only)Dielectric Strength: Between power supply/COM DC500V/ 1 min.
Between -SIG/case AC1500V/ 1 min.Insulation Resistance: DC500V 100MW at above terminalsAccessory: Instruction manual, connectorZero Adjustment: ±0.3mV/VGain Adjustment: 1mV/V~3mV/V to fullscale 1999Zero Drift: 0.02% FS/°CGain Drift: 0.02% rdg/°CAnalog Output: 1mV/digit
0.5% FS, less than 250ppm more than100msec, more than 500W
External Control: Hold
Comparator SectionSetting Range: 10~+1999 (HI and LO)Setting Method: By VolumeSetting Accuracy: Setting value ±2 digit (23°C ±5°C) (Typ.)Relay Contact Capacity: 250VAC 0.1A resistive load
120VAC 0.5A resistive load28VDC 1A resistive load
Comparative Condition: HI setpoint%Indication HILO setpoint.Indication LO
Hysteresis: 5~12 digitResponse Time: less than 100msec
Ordering Code
ASG-251
STRAIN GAUGE METERASG-251
HI LO
48
24
Min.65Min.35
45 +0.6 -0
22.2
+0.3
-0
Front
Side
Panel cut
COMa c b HOLD
POWER
0V +24Va c
Lo
b
HI
1 2 3 4 5 6 7 8 9 10
Features
• Hi and Lo Set points
• Bright LED, 8mm (RED)
• Excitation Supply 20mA at DC5V
Load Cell Direct Input
22 21
87
Panel thickness 0.8 to 3.5mm
NCNCCOM-EXC+EXC-SIG
INPUT
+SIG NC COMANALOG OUT
1 2 3 4 5 6 7 8 9 10
Upper
Lower
ASAHI KEIKI CO.,LTD. 61
A7000
A7000 SERIES DIGITAL PANEL METERA7000
Features
• Power supply 100 to 240VAC
12 to 48VDC
• Panel cut out 72mm(W) 36mm(H)
• Option BCD output, RS-232C, RS-485
• HH, HI, GO, LO, LL setpoints
• Input DC, AC, TC, RTD, Frequency, Strain Gauge
Resistance
Common SpecificationMaximum display: 9999Overrange indication: When input exceed the maximum display
display OVER or –OVERZero display: Leading zero suppressionDecimal point: Settable to any digit positionOperating temp: 0 to 50°C(35 to 85% RH)Storage temp.: –10 to 70°C less than 60%RHPower supply: 100 to 240VAC±10%
12 to 48VDC ±10%Power consumption: 8VA(At AC) 7W(At DC)Dimensions: 72mm(W)X36mm(H)X118mm(D)Weight:approx: 160gDielectric strength(AC): Power supply/input terminal/output terminal
AC1500V/min(DC): Power supply/input terminal/output terminal
DC500V/minInput terminal/output terminal DC500V/min
Insulation resistance: DC500V more than 100M Ω at the aboveterminals
A7X11-X
±99.99mV±999.9mV±9.999V±99.99V±700V
Display
±50V±50V
±250V±250V±700V
1112131415
±(0.03% of rdg+1digit)
±(0.1% of rdg+2digit)
offset ±9999full scale ±9999
Range Measurement Range InputProtection
Accuracy(23°C±5°C,35~85%RH)
Conversion rate: 100times/sec
Input Specifications
DC voltage, current
A7X12-X
±99.99µA±999.9µA±9.999mA±99.99mA
Display
±10mA±50mA±50mA
±700mA
21222324
±(0.1% of rdg +2 digit)offset ±9999full scale ±9999
Range Measurement Range InputProtection
Accuracy(23°C±5°C,35~85%RH)
Conversion rate: 100times/sec
A7X13-X
±999.9mA±2.000A
Display
±3A2526
±(0.1% of rdg +2 digit)offset ±9999full scale ±9999
Range Measurement Range InputProtection
Accuracy(23°C±5°C,35~85%RH)
Conversion rate: 100times/sec
AC voltage, current (TRUE-RMS)
A7X14-X
99.99mV999.9mV9.999V99.99V700.0V
Display
50V50V250V250V700V
1112131415
offset ±9999full scale ±9999
Range Measurement Range InputProtection
Accuracy(23°C±5°C,35~85%RH)
±(0.2% of rdg +20 digit)
±(0.3%of rdg +20 digit)
Minimum display 50 digitsFrequency range: 40Hz to 1kHzResponse time: Approx 1 sec(10% to 90%)Conversion rate: 1000times/sec
A7X15-X
99.99µA999.9µA9.999mA99.99mA
Display
10mA50mA50mA500mA
21222324
±(0.5%of rdg +20 digit)offset ±9999full scale ±9999
Range Measurement Range InputProtection
Accuracy(23°C±5°C,35~85%RH)
Minimum display 50 digitsFrequency range: 40Hz to 1kHzResponse time: Approx 1 sec(10% to 90%)Conversion rate: 1000times/sec
A7X16-X
999.9mA5A
Display
3A8A
2526
±(0.7%of rdg +20 digit)offset ±9999full scale ±9999
Range Measurement Range InputProtection
Accuracy(23°C±5°C,35~85%RH)
Minimum display 50 digitsFrequency range: 40Hz to 1kHzResponse time: Approx 1 sec(10% to 90%)Conversion rate: 1000times/sec
Resistance
A7X17-X
99.99Ω999.9Ω9.999kΩ99.99Ω
Display
5mA0.5mA50µA5µA
11121314
offset ±9999full scale ±9999
Range Measurement Range Current Accuracy(23°C±5°C,35~85%RH)
±(0.1% of rdg + 4 digit)
Conversion rate: 100times/secMeasurement method: Two or Four wire (internal socket changable)
NEW!
ASAHI KEIKI CO.,LTD.62
A70
00
Thermocouple · RTD
A7X18-X
KKJTSRB
PT100ΩPT100Ω
–50.0 to 199.9°C–50 to 1200°C–50 to 1000°C–50 to 400°C0 to 1700°C
–10 to 1700°C100 to 1800°C
–100.0 to 199.9°C–100 to 600°C
MeasurementRange
0.1°C1°C1°C1°C1°C1°C1°C
0.1°C1°C
± (0.5% of FS)± (0.2% of FS)± (0.2% of FS)± (0.6% of FS)± (0.4% of FS)± (0.4% of FS)± (0.4% of FS)
± (0.15% of FS)± (0.3% of FS)
KAKBJTSRB
PAPB
Range Sensor type MaximumResolution
Accuracy(23°C±5°C,35~85%RH)
available Fahrenheit display
Cold junction compensator accuracy: ±2°C(10 to 40°C)Sensor lead resistance: less than 50ΩLinearzing method: Digital linearizingBurn out alarm: - - - - -Conversion time: 2.5times/sec
Frequency
A7X19-X
0.1 to 999.9Hz 1 to 9.999kHz10 to 99.99kHz
111213
±(0.2% of FS)
Range Measurement Range Accuracy(23°C±5°C,35~85%RH)
L:less than 1.5V(5V, pullup)L:less than 1V, HI:2.5 to 15V
0.3 to 30V P-P30V rms to 500V rms
30V15V30V500V
Open collectorLogic
MagentVoltage
Input type Input voltage level Input Protection
Prescale: 0.01~10.00PPR: 1~100Power supply for sensor: 12VDC±10%
Strain gauge
A7X1A-X
–1 to +1mV/V 1 to 3mV/V
Span adjustmentrange
–4~+4mV/V ±(0.1% of FS)+2 digit
5V10V
Sensor Zero adjustmentrange
Measurementrange Accuracy
Sensor: 350 ΩPower supply for sensor: 5 V±5% (less than 15 mA)
10 V±5% (less than 30 mA)Conversion speed: 1000/sec
Process
A7X1B-X
1 to 5V±5V
4 to 20mA±20mA
Display
1V2V2A3A
offset ±9999full scale 0 to ±9999
Range MeasurementRange Accuracy
±(0.03% of rdg +2digit
±(0.1% of rdg +3digit
Conversion rate: 1000times/secExcitation power supply: 12VDC ± 5%
24VDC ± 5% 25mA
Indication > High High setpointHigh High setpoint>=Indication>High setpoint
High setpoint>=Indication>=Lo setpointLow setpoint>Indication>=Low Low setpoint
Low Low setpoint>Indication
HHHIGOLOLL
Setting range: –9999 to 9999Hysteresis: 1 to 999 digit for each setpointsRelay contact capacity: AC125V 0.3A resistive load
DC30V 1A resistive loadPhotocoupler capacity: DC30V 50mA
Output Specification
HH,HI & LO, LLsetpoints outputComparative condition :
BCD outputType of output: Open collector or TTLLogic: ChangeableOutput rate: DC30V 10mA(open collector)
Funout 2(TTL)
Analog output (PWM)
more than 10kΩ
less than 550Ω
±(0.5% of F.S)50mV p-p
25mV p-p
0 to 1V0 to 10V1 to 5V
4 to 20mA
Output Load resistance Accuracy Ripple
Output method: PWM methodScaling: Digital scalingResolution: 13 bitResponse time: approx 0.5sec
RS232C (Conforming to EIA RS-232C)Communication method: Full duplexTransmission speed: 4800/9600/19200/38400 bpsStart bit : 1 bitData length: 7 bit/8 bitParity: Even parity/ odd parityStop bit: 1 bit/2 bitCharacter code: ASCII codeTransmission control process: Ignord process
RS-485 (Conforming to EIA RS-485)Communication method: Full duplexTransmission speed: 4800/9600/19200/38400 bpsStart bit: 1 bitData length: 7 bit/ 8 bitParity: Even parity/ odd marityError detection: BCCStop bit: 1 bit/2 bitCharacter code: ASCII codeTransmssion control process: Ignord processSignal name: + non reversal output
– reversal outputMaximum no of meter connected: 31Line length: up to 500m in total
A7000 SERIES DIGITAL PANEL METERA7000
ASAHI KEIKI CO.,LTD. 63
A7000
Ordering CodeA 7 1 –
Output
Input
0. none1. Relay output2. Photocoupler output3. BCD output (TTL)4. BCD output (Open collector)5. BCD output (TTL), Photocoupler output6. BCD output (Open collector),
Photocoupler output7. Analog output8. Analog output, Photocoupler output9. RS-232CA. RS-485B. RS-232C, Photocoupler outputC. RS-485, Photocoupler output
1. DC voltage2. DC current3. DC current4. AC Voltage5. AC current6. AC current7. Resistance8. Temperature (T/C, RTD)9. FrequencyA. Strain gaugeB. Process
Power supply 1. AC100 to 240V2. DC12 to 48V
Dimensions
68
80
87
72
36
7
118
33
HHHIGOLOLL
REPHDZMEP1P2P3
ME
Min.96
68+0.7–0
33–0 +
0.6
A7000 SERIES DIGITAL PANEL METERA7000
ASAHI KEIKI CO.,LTD.64
A60
00A6000 SERIES DIGITAL PANEL METER
A6000 Features
• Power supply 100 to 240VAC
12 to 48VDC
• Panel cut out 96mm(W) 48mm(H)
• Option BCD output, RS-232C, RS-485
• HI, GO, LO 2 setpoints, Analog output
• Input DC, AC, TC, RTD, Frequency, Strain Gauge
Resistance
Common SpecificationDisplay: Main display Red or Green LED 20 mm
Sub display Red LED 6 mmConversion rate: 1000 times/sec.Maximum display: 9999Overrange indication: When input exceed the maximum display
display OVER or –OVERZero display: Leading zero suppressionDecimal point: Settable to any digit positionOperating temp.: 0 to 50°C 35 to 85%RHStorage temp.: –10 to 70°C less than 60%%RHPower supply: AC 100 to 240 V ±10%
DC 12 to 48 V ±10%Power consumption: 8 VA (max. load)Dimensions: 96 mm(W)X 48 mm(H)X 97.5 mm(D)DIN sizeWeight: approx. 450 gDielectric strength(AC): Power supply/input terminal/output terminal
AC1500 V/min.(DC): Power supply/input terminal/output terminal
DC500 V/min.(Common): Case/each terminal
AC1500 V/min.Insulation resistance: DC500 V more than 100 MΩ at the above
terminals
A6XX1-XX
±99.99mV±999.9mV±9.999V±99.99V±700V
Display
±50V±50V
±250V±250V±700V
1112131415
±(0.03% of rdg+1digit)
±(0.1% of rdg+2digit)
offset ±9999full scale ±9999
Range Measurement Range InputProtection
Accuracy(23°C±5°C,35~85%RH)
Input Specifications
DC voltage, current
A6XX2-XX
±99.99µA±999.9µA±9.999mA±99.99mA
Display
±10mA±10mA±50mA
±500mA
21222324
±(0.1% of rdg +2 digit)offset ±9999full scale ±9999
Range Measurement Range InputProtection
Accuracy(23°C±5°C,35~85%RH)
A6XX3-XX
±999.9mA±2.000A
Display
±3A2526
±(0.1% of rdg +2 digit)offset ±9999full scale ±9999
Range Measurement Range InputProtection
Accuracy(23°C±5°C,35~85%RH)
AC voltage, current (TRUE-RMS)
A6XX4-XX
99.99mV999.9mV9.999V99.99V700.0V
Display
50V50V250V250V700V
1112131415
offset ±9999full scale ±9999
Range Measurement Range InputProtection
Accuracy(23°C±5°C,35~85%RH)
±(0.2% of rdg +20 digit)
±(0.3%of rdg +20 digit)
Minimum display 50 digits
A6XX5-XX
99.99µA999.9µA9.999mA99.99mA
Display
10mA50mA50mA500mA
21222324
±(0.5%of rdg +20 digit)offset ±9999full scale ±9999
Range Measurement Range InputProtection
Accuracy(23°C±5°C,35~85%RH)
Minimum display 50 digits
A6XX6-XX
999.9mA5A
Display
3A8A
2526
±(0.7%of rdg +20 digit)offset ±9999full scale ±9999
Range Measurement Range InputProtection
Accuracy(23°C±5°C,35~85%RH)
Minimum display 50 digits
Resistance
A6XX7-XX
99.99Ω999.9Ω9.999kΩ99.99kΩ
Display
5mA0.5mA50µA5µA
11121314
offset ±9999full scale ±9999
Range Measurement Range Current Accuracy(23°C±5°C,35~85%RH)
±(0.1% of rdg + 4 digit)
Measurement method: Two or Four wire (internal socket changable)
NEW!
(Multiple) (Single)
ASAHI KEIKI CO.,LTD.
A6000
65
A6000 SERIES DIGITAL PANEL METERA6000
Thermocouple · RTD
A6XX8-XX
KKJTSRB
PT100ΩPT100Ω
–50.0 to 199.9°C–50 to 1200°C–50 to 1000°C–50 to 400°C0 to 1700°C
–10 to 1700°C100 to 1800°C
–100.0 to 199.9°C–100 to 600°C
MeasurementRange
0.1°C1°C1°C1°C1°C1°C1°C
0.1°C1°C
± (0.5% of FS)± (0.2% of FS)± (0.2% of FS)± (0.6% of FS)± (0.4% of FS)± (0.4% of FS)± (0.4% of FS)
± (0.15% of FS)± (0.3% of FS)
KAKBJTSRB
PAPB
Range Sensor type MaximumResolution
Accuracy(23°C±5°C,35~85%RH)
available Fahrenheit display Cold junction compensator accuracy : ±2°C(10 to 40°C)Sensor lead resistance: : less than 50ΩLinearzing method: : Digital linearizingBurn out alarm: : - - - - -Conversion time: : 2.5times/sec
Frequency
A6XX9-XX
0.1 to 999.9Hz 1 to 9.999kHz10 to 99.99kHz
111213
±(0.2% of FS)
Range Measurement Range Accuracy(23°C±5°C,35~85%RH)
L:less than 1.5V(5V, pullup)L:less than 1V, HI:2.5 to 15V
0.3 to 30V P-P30V to 500V rms
30V15V30V500V
Open collectorLogic
MagentVoltage
Input type Input voltage level Input Protection
Prescale : 0.01~10.00PPR : 1~100Power supply for sensor : 12VDC±10%
Strain gauge
A6XXA-XX
–1 to +1mV/V 1 to 3mV/V
Span adjustmentrange
–4~+4mV/V ±(0.1% of FS)+2 digit
5V10V
Sensor Zero adjustmentrange
Measurementrange Accuracy
Sensor : 350 ΩPower supply for sensor : 5 V±5% (less than 15 mA)
10 V±5% (less than 30 mA)Conversion speed : 1000/sec
Process
A6XXB-XX
1 to 5V±5V
4 to 20mA±20mA
Display
1V2V2A3A
offset ±9999full scale 0 to ±9999
Range MeasurementRange Accuracy
±(0.03% of rdg +2digit)
±(0.1% of rdg +3digit)
Excitation power supply: 12VDC ± 5%24VDC ± 5% 25mA
Indication > High setpointHigh setpoint >= Indication >= Lo setpoint
Indication < Lo setpoint
HIGOLO
Setting range : -9999 to 9999Hysteresis : 1 to 999 digit for each setpointsRelay contact capacity : AC250 V 2 A resistive load
DC30 V 2 A resistive loadPhotocoupler capacity : DC30 V 20 mA
Output Specification
HI & LO setpoints output (A6XXX-1X Reply output)(A6XXX-2X Photocoupler)
Comparative condition
pattern 1 pattern 2 pattern 3 pattern 4 pattern 5 pattern 6 pattern 7 pattern 8P.SEL1 OFF ON OFF ON OFF ON OFF ONP.SEL2 OFF OFF ON ON OFF OFF ON ONP.SEL3 OFF OFF OFF OFF ON ON ON ON
ON : Shorted between COM terminal and P.SEL terminal or same levelOFF : Open between COM terminal and P.SEL terminal or 5 V
Start/Hold : shorted between COM terminal or same level holdOpen COM terminal and start/hold terminal or 5 V start
D.ZERO : Shorted between COM terminal and D.ZERO terminal ONP.HOLD : Shorted between COM terminal and P.HOLD terminal ONR.RE(relay reset) : Shorted between COM terminal and R.RE terminal ONP.SEL1 to 3 : as below
External control (A6XXX-X1)
Option
BCD output (A6XXX-X2 TTL)(A6XXX-X3 Open collector)
Type of output: Open collector or TTLLogic: ChangeableOutput rate: DC30V 10mA(open collector)
Funout 2(TTL)
Analog output (A6XXX-X4)
more than 10kΩ
less than 550Ω
±(0.5% of F.S)50mV p-p
25mV p-p
0 to 1V0 to 10V1 to 5V
4 to 20mA
Output Load resistance Accuracy Ripple
Output method : PWM methodScaling : Digital scalingResolution : 13 bitReponse time : approx 0.5sec
RS232C (Conforming to EIA RS-232C)(A6XXX-X5)Communication method : Full duplexTransmission speed : 4800/9600/19200/38400 bpsStart bit : 1 bitData length : 7 bit/8 bitParity : Even parity/ odd parity/ noneStop bit : 1 bit/2 bitCharacter code : ASCII codeTransmission control process : Ignord process
RS-485 (conforming to EIA RS-485)(A6XXX-X6)Communication method : Full duplexTransmission speed : 4800/9600/19200/38400 bpsStart bit : 1 bitData length : 7 bit/ 8 bitParity : Even parity/ odd marity/ noneError detection : BCCStop bit : 1 bit/2 bitCharacter code : ASCII codeTransmssion control process : Ignord processSignal name : +non reversal output
- reversal outputMaximum no of meter connected : 31Line length : up to 500m in total
ASAHI KEIKI CO.,LTD.66
A60
00A6000 SERIES DIGITAL PANEL METER
A6000 Ordering CodeA6 -
Option 0. none1. External control2. BCD output (TTL)3. BCD output (open collector)4. Analog output5. RS-232C6. RS-4857. RS-232C, analog output8. RS-485, analog output
Comparator output 0. none1. Relay2. Photocoupler
Input 1. DC voltage2. DC current3. DC current4. AC voltage5. AC current6. AC current7. Resistance8. Temperature (T/C, RTD)9. FrequencyA. Strain gaugeB. Process
Display board 1. Multiple2. Single
Power supply 1. AC 100 to 240 V2. DC12 to 48 V
Dimensions
Multiple
Input Option
Comparator Power
Single
48
(97.
5)
10.9
77
0.5
(86.
5)
(21.
5)
44.8
91.5
102.5
96
45+
0.6
-0
92 +0.8- 0
MIN
.70
MIN.120
ASAHI KEIKI CO.,LTD.
Transmitter
69
TERMINAL TYPE TRANSMITTERTZ-1X
Output signalDC 0 to 5VDC 1 to 5VDC 0 to 10VDC –10 to 10VDC 4 to 20mA
Output load resistance
more than 2kΩ
more than 4kΩ
less than 550Ω
Code No.0123AY special
Special Voltage output: DC -10 to 10V span 0.06 to 20V Current output: DC 0 to 20mA span 1 to 20mA
Output specifications
Ordering CodeInput signal
DC 0 to 5VDC 1 to 5VDC 0 to 10VDC –10 to 10VDC 0 to 1VDC 0 to 0.1VDC 0 to 0.06VDC 0 to 20VDC –2 to 2VDC –5 to 5VDC 4 to 20mADC 0 to 20mA
Allowable input
-50 to +150%F.S
Input Resistance
more than 1MΩ
250Ω
Code No.0123456789ABY special
Special Voltage input: DC -250V to 250V span 0.06 to 500VCurrent input: DC 0 to 50mA span DC 1mA to 50mA
Input specifications
TZ -1X-
Output
Input
0. DC 0 to 5V1. DC 1 to 5V2. DC 0 to 10V3. DC -10 to 10VA. DC 4 to 20mAY. special
Response time L. 50msecH. 1msec
0. DC 0 to 5V1. DC 1 to 5V2. DC 0 to 10V3. -10 to 10V4. DC 0 to 1V5. DC 0 to 0.1V6. DC 0 to 0.06V7. DC 0 to 20V8. DC -2 to 2V9. DC -5 to 5VA. DC 4 to 20mAB. DC 0 to 20mAY. special
Features
・ AC power supply 100 to 240VAC
・ DIN rail mounting
・ Input/Output/Power supply isolated
12
34
56
78
Load
Caution: Be polarity careful
PowerSupply(AC)
Inpu
t Sig
nal
Connection Diagram
ZERO SPAN
3(+)
4(–)
2
1
NC
Input SignalInput
Circuit
Isolation AMP
OutputCircuit
Powe
r Sup
ply Ci
rcuit
5(+)
6(-)
Output Signal
AC 100V
Block Diagram
Dimensions
Front
Side
98.1
25
94
35.2
37.3
40.8
9847
Terminal Cover
Slide Bar
1
2
3
4
5
6
7
8
General specificationsAccuracy: ±0.1% F.S (25˚C±2˚C)Fluctuating power source: ±0.06% F.SFluctuating load: ±0.06% F.STemp. Coefficient: ±0.02% F.S/˚CResponse time: 50msec or 1msec(TYP) (0 to 90%)Adustable volume range: ±5% F.S or more (zero and span)Insulated Resistance: input/output/power supply, more than 100MΩDielectric strength: input/output/power supply, AC2000V/1 min.Power supply: 100 to 240VAC±10%Power consuption: less than 30mA (at 100VAC)Operating Temp: -5 to 50˚C
Less than 90% RHCase Material: Black ABSWeight: Approx. 100g
NEW!
ASAHI KEIKI CO.,LTD.70
Tran
smitt
erTERMINAL TYPE TRANSMITTER
TZ-1B
Output signalDC 0 to 5VDC 1 to 5VDC 0 to 10VDC –10 to 10VDC 4 to 20mA
Output load resistance
more than 2kΩ
more than 4kΩ
less than 550Ω
Code No.0123AY Special
Special Voltage output: DC -10 to 10V span 0.06 to 20VCurrent output: DC 0 to 20mA span 1 to 20mA
Output specifications
Ordering CodePotentiometer100 to 10kΩ
special
Input range
0 to 100%
Code No.1Y
Special 100 to 10kΩ (span range 50% or more)Dip switch for only available input code 1SW1 ON: 0 to 100% (span adjust range 95 to 105%) SW2 ON: 0 to 90% (span adjust range 85 to 95%) SW3 ON: 0 to 80% (span adjust range 75 to 85%) SW4 ON: 0 to 70% (span adjust range 65 to 75%)
Input specifications
TZ -1B-
Output
Input
0. DC 0 to 5V1. DC 1 to 5V2. DC 0 to 10V3. DC -10 to 10VA. DC 4 to 20mAY. special
1. 0 to 100%Y. special
Features
・ AC power supply 100 to 240VAC
・ DIN rail mounting
・ Input/Output/Power supply isolated
12
34
56
78
MAX
MIN
Pot
entio
met
er
Load
Out
put S
igna
l
Caution: Be polarity careful
PowerSupply(AC)
Connection Diagram
ZERO
5(+)
6(-)2
1
4
3
SPANBase Circuit
InputCircuit
Isolation AMP
OutputCircuit
Powe
r Sup
ply Ci
rcuit
Output Signal
Pot
entio
met
er
AC 100V
Block Diagram
Dimensions
Front
Side
98.1
25
94
35.2
37.3
40.8
9847
Terminal Cover
Slide Bar
1
2
3
4
5
6
7
8
General specificationsAccuracy: ±0.1% F.S (25˚C±2˚C)Fluctuating power source: ±0.06% F.SFluctuating load: ±0.06% F.STemp. Coefficient: ±0.02% F.S/˚CResponse time: 50msec(TYP) (0 to 90%)Change setting error: less than ±2% (0 to 100% at deliver)Adustable volume range: ±5% F.S or more (zero and span)Insulated Resistance: input/output/power supply, more than 100MΩDielectric strength: input/output/power supply, AC2000V/1 min.Power supply: 100 to 240VAC±10%Power consuption: less than 30mA (at 100VAC)Operating Temp: -5 to 50˚C
Less than 90% RHCase Material: Black ABSWeight: Approx. 100g
NEW!
ASAHI KEIKI CO.,LTD.
Transmitter
71
TERMINAL TYPE TRANSMITTERTZ-1D
Output signalDC 0 to 5VDC 1 to 5VDC 0 to 10VDC –10 to 10VDC 4 to 20mA
Output load resistance
more than 2kΩ
more than 4kΩ
less than 550Ω
Code No.0123AY special
Special Voltage output: DC -10 to 10V span 0.06 to 20V Current output: DC 0 to 20mA span 1 to 20mA
Output specifications
Ordering CodeInput signalAC 0 to 1AAC 0 to 5A
Allowable inputInput Resistance
less than 0.05Ω
Code No.12Y special
less than 7.5A(15A, within 1ms)
Special Less than AC 0 to 5A span 1 to 5AInput Frequency 40hz to 1kHz
Input specifications
TZ -1D-
Output
Input
0. DC 0 to 5V1. DC 1 to 5V2. DC 0 to 10V3. DC -10 to 10VA. DC 4 to 20mAY. special
1. AC 0 to 1A2. AC 0 to 5AY. special
Features
・ AC power supply 100 to 240VAC
・ DIN rail mounting
・ Input/Output/Power supply isolated
12
34
56
78
Inpu
t Sig
nal
Load
Out
put S
igna
l
Caution: Be polarity careful
PowerSupply(AC)
Connection Diagram
ZERO
1
2
3
6
NC
CT
SPAN
Input Signal OutputCircuit
Powe
r Sup
ply Ci
rcuit
5(+)
6(-)
Output Signal
AC 100V
T-RMSset-up
diagram
Block Diagram
Dimensions
Front
Side
98.1
25
94
35.2
37.3
40.8
9847
Terminal Cover
Slide Bar
1
2
3
4
5
6
7
8
General specificationsAccuracy: ±0.15% F.S (5 to 100% F.S)
±0.5% F.S (0 to 5% F.S)25˚C±2˚C
Fluctuating power source: ±0.06% F.SFluctuating load: ±0.06% F.SFluctuating frequency: ±0.2% F.S(60Hz)Temp. Coefficient: ±0.02% F.S/˚CResponse time: Less than 700msec (TYP) (0 to 90%)Adustable volume range: ±5% F.S or more (zero and span)Insulated Resistance: input/output/power supply, more than 100MΩDielectric strength: input/output/power supply, AC2000V/1 min.Power supply: 100 to 240VAC±10%Power consuption: Less than 30mA (at 100VAC)Operating Temp: -5 to 50˚C
Less than 90% RHCase Material: Black ABSWeight: Approx. 100g
NEW!
ASAHI KEIKI CO.,LTD.72
Tran
smitt
erTERMINAL TYPE TRANSMITTER
TZ-1E
Output signalDC 0 to 5VDC 1 to 5VDC 0 to 10VDC –10 to 10VDC 4 to 20mA
Output load resistance
more than 2kΩ
more than 4kΩ
less than 550Ω
Code No.0123AY special
Special Voltage output: DC -10 to 10V span 1 to 20V Current output: DC 0 to 20mA span 1 to 20mA
Output specifications
Ordering CodeInput signal
AC 0 to 35VAC 0 to 100VAC 0 to 110VAC 0 to 200VAC 0 to 220V
Allowable inputInput Resistance
more than 1MΩ
Code No.12345Y special
less than 150%(Max. AC250V)
Special Voltage input: AC 0 to 250V span 4 to 250VInput Frequency : 40Hz to 1KHz
Input specifications
TZ -1E-
Output
Input
0. DC 0 to 5V1. DC 1 to 5V2. DC 0 to 10V3. DC -10 to 10VA. DC 4 to 20mAY. special
1. AC 0 to 35V2. AC 0 to 100V3. AC 0 to 110V4. AC 0 to 200V5. AC 0 to 220VY. special
Features
・ AC power supply 100 to 240VAC
・ DIN rail mounting
・ Input/Output/Power supply isolated
12
34
56
78
Load
Out
put S
igna
l
Caution: Be polarity careful
PowerSupply(AC)
Inpu
t Sig
nal
Connection Diagram
ZERO
1
2
3(+)
4(-)
NC
SPAN
Input SignalOutputCircuit
Powe
r Sup
ply Ci
rcuit
5(+)
6(-)
Output Signal
AC 100V
T-RMSset-up
diagram
Isolation AMP
Block Diagram
Dimensions
Front
Side
98.1
25
94
35.2
37.3
40.8
9847
Terminal Cover
Slide Bar
1
2
3
4
5
6
7
8
General specificationsAccuracy: ±0.15% F.S (5 to 100% F.S)
±0.5% F.S (0 to 5% F.S)25˚C±5˚C
Fluctuating power source: ±0.06% F.SFluctuating load: ±0.06% F.SFluctuating frequency: ±0.2% F.S (60Hz)Temp. Coefficient: ±0.02% F.S/˚CResponse time: less than 700msec(TYP) (0 to 90%)Adustable volume range: ±5% F.S or more (zero and span)Insulated Resistance: input/output/power supply, more than 100MΩDielectric strength: input/output/power supply, AC2000V/1 min.Power supply: 100 to 240VAC±10%Power consuption: less than 30mA (at 100VAC)Operating Temp: -5 to 50˚C
Less than 90% RHCase Material: Black ABSWeight: Approx. 100g
NEW!
ASAHI KEIKI CO.,LTD.
Transmitter
73
TERMINAL TYPE TRANSMITTERTZ-1F
Output signalDC 0 to 5VDC 1 to 5VDC 0 to 10VDC –10 to 10VDC 4 to 20mA
Output load resistance
more than 2kΩ
more than 4kΩ
less than 550Ω
Code No.0123AY special
Special Voltage output: DC -10 to 10V span 0.06 to 20V Current output: DC 0 to 20mA span 1 to 20mA
Output specifications
Ordering CodeInput signal
DC 0 to 5mVDC 1 to 10mVDC 0 to 50mVDC 0 to 60mVDC 0 to 100mVDC 0 to 10µADC 0 to 100µADC 0 to 200µA
Allowable inputInput Resistance
more than 1MΩ
more than 1KΩ
less than 500Ω
Code No.01234ABCY special
-50 to +150%F.S
Special Voltage input: DC -100mV to 100mV span DC 5 to 200mVCurrent input: DC -5mA to 5mA span DC 10µA to 10mA
Input specifications
TZ -1F-
Output
Input
0. DC 0 to 5V1. DC 1 to 5V2. DC 0 to 10V3. DC -10 to 10VA. DC 4 to 20mAY. special
Response time L. 50msecH. 3msec
0. DC 0 to 5mV1. DC 0 to 10mV2. DC 0 to 50mV3. DC 0 to 60mV4. DC 0 to 100mVA. DC 0 to 10µAB. DC 0 to 100µAC. DC 0 to 200µAY. special
Features
・ AC power supply 100 to 240VAC
・ DIN rail mounting
・ Input/Output/Power supply isolated
12
34
56
78
Load
Caution: Be polarity careful
PowerSupply(AC)
Inpu
t Sig
nal
Connection Diagram
ZERO SPAN
3(+)
4(–)
2
1
NC
Input SignalInput
Circuit
Isolation AMP
OutputCircuit
Powe
r Sup
ply Ci
rcuit
5(+)
6(-)
Output Signal
AC 100V
Block Diagram
Dimensions
Front
Side
98.1
25
94
35.2
37.3
40.8
9847
Terminal Cover
Slide Bar
1
2
3
4
5
6
7
8
General specificationsAccuracy: ±0.1% F.S (25˚C±2˚C)Fluctuating power source: ±0.06% F.SFluctuating load: ±0.06% F.STemp. Coefficient: ±0.02% F.S/˚CResponse time: 50msec or 3msec(TYP) (0 to 90%)Adustable volume range: ±5% F.S or more (zero and span)Insulated Resistance: input/output/power supply, more than 100MΩDielectric strength: input/output/power supply, AC2000V/1 min.Power supply: 100 to 240VAC±10%Power consuption: less than 30mA (at 100VAC)Operating Temp: -5 to 50˚C
Less than 90% RHCase Material: Black ABSWeight: Approx. 100g
NEW!
ASAHI KEIKI CO.,LTD.74
Tran
smitt
erPROGRAMMABLE TRANSMITTER
TW-3M
0 to 5 VDC1 to 5 VDC0 to 10 VDC4 to 20 mADC0 to 20 mADC
More than 2 kΩMore than 2 kΩMore than 4 kΩLess than 550 ΩLess than 550 Ω
Output signal Allowable load resistance
Output Specification
Ordering Code
0 to 5 VDC1 to 5 VDC0 to 10 VDC0 to 60 mVDC4 to 20 mADC0 to 20 mADC
More than 1 MΩ
250 Ω
Input signal Input resistance
Input Specification
TW-3M - -
1: 100 - 240VAC4: 24VDC (CE available)
C: Connector (screw) Type (UL available)N: Screw Type
Features
・ Can change input and output by front Dip switch
・ 100 to 240 VAC or 24 VDC power supply
・ DIN rail mount type
6
5
4
3
2
1
12
11
10
9
8
7
Inputsignal
Power(AC)
Outputsignal
Power(DC)
Note: When conducting wiring, be careful with its polarity.
Connection Diagram
Input signalOutput signal
ZERO SPAN
Power
75
68
11
12
Isolated Amp.
Power circuit
Output
circuit
Input
circuit
Block Diagram
General SpecificationsLinearity: Less than ± 0.1% F.STemperature characteristic: ± 0.02% F.S/°CResponse time: Less than 50ms ( 0 to 90%)Insulantion resistance: Between input and output or power supply,
more than 100MΩDielectric strength: Between input and output or power supply,
for 1 min. at 2000VACPower supply: 24VDC ±10%
100-240VAC ±10%Power comsumption: Less than 80mA (at 24VDC)
Less than 50mA (at 100-240VAC)Operationg temperature: -5 to 50°COperating humidity: Less than 90%
(No dew-condensing)Case material: Black PBT 94-V0Weight: Approx. 130g
Dimensions
ON
OF
F
1 2
3 4
SW
1
ON
OF
F SPA
N
ZER
O1 2
3 4
5 6
7 8
SW
2
Front view
Side view
35.4
35.2 4.5
1841
64.5
Sliding from 96 to 98
94
2048
I/Ora
nge
setti
ng D
ipS
Ws.
ZE
RO
/SPA
Nad
just
ers
Setting or changing input/output range
1. Setting or changing input rangeSW1
0-5V ONOFF
SW2
1-5V ONOFF
0-10V ONOFF
0-60mV ONOFF
4-20mA ONOFF
0-20mA ONOFF
1 2 3 4 1 2 3 4 5 6 7 8
2. Setting or changing output rangeSW1
0-5V ONOFF
SW2
1-5V ONOFF
0-10V ONOFF
4-20mA ONOFF
0-20mA ONOFF
1 2 3 4 1 2 3 4 5 6 7 8
(C Type) (N Type)
ASAHI KEIKI CO.,LTD.
Transmitter
75
TRANSMITTER WITH ONE INPUT AND TWO OUTPUTSTW-2X
Other than the above
Code No.AY
Output signal4-20mA DC
Load resistanceLess than 550 ohm
Limit of Y specificationsCurrent output : 20mADC or less , Minimum span ; 1mADCVoltage output : From -10VDC to +10VDC
Minimum span ; 1VDC
Other than the above
Code No.012ABY
Output signal0-5V DC1-5V DC
0-10V DC4-20mA DC0-20mA DC
Load resistance
Less than 2K ohm
Less than 4K ohm
Less than 550 ohm
Limit of Y specificationsCurrent output : 20mADC or less , Minimum span ; 1mADCVoltage output : From -10VDC to +10VDC
Minimum span ; 1VDC
First output specifications
Second output specifications
Ordering Code
Other than the above
Code No.012ABY
Intput signal0-5V DC1-5V DC
0-10V DC4-20mA DC0-20mA DC
Input resistance
More than 1M ohm
250 ohm
Limit of Y specificationsVoltage input : 250VDC or less , Minimum span ; 100mVDCCurrent input : 50mADC or less , Minimum span ; 1mADC
Input specifications
TW-2X -
Second Output code
First Output code
Input code
0: 0 - 5V DC1: 1 - 5V DC2: 0 - 10V DCA: 4 - 20mA DCB: 0 - 20mA DCY: SpecialA: 4 - 20mA DCY: Special0: 0 - 5V DC1: 1 - 5V DC2: 0 - 10V DCA: 4 - 20mA DCB: 0 - 20mA DCY: Special
- 4 -C: Connector (screw) TypeN: Screw Type
Features
・ DIN rail mount
・ 2 outputs
・ Input/output1/output2/power supply Isolated
Note: Pay attention to the connection polarity.
Signalinput
Signaloutput1
DC24V
Signaloutput2
TW-2X
654321
121110987
-
+
-
+
-
+
-
+
Connection Diagram
Inputcircuit
Outputcircuit
Isoration Amp.
Powe
r circ
uit
Isolation Amp.
1
Outputcircuit
2
ZEROSPAN
TW-2X
ZEROSPAN
Signaloutput 2
DC 24V
NC
Signaloutput 1
Signalinput
5(+)
1(+)
6(–)
2(–)
11(+)
7(+)
12(–)
9
10NC
3
4
8(–)
Block Diagram
Dimensions
Front view
Side view
Withterminalcover
64.5
94
96~98
35.4
2017
.4
42.5
4.3
4841
ZE
RO
OU
T 1
SPA
N
OU
T 1
ZE
RO
OU
T 2
SPA
N
OU
T 2
General specificationsAccuracy: ±0.25% FSTemperature characteristic: ±200 ppm FS/ (TYP)Response time: Less than 50msec ( 0 to 90%)Insulantion resistance: Between input and/output 1/output 2/power ;
More than 100MΩ (at 500VDC)Dielectric strength: Between input and/output 1/output 2/power ;
For 1 min. at 2000VACPower supply voltage: 24VDC ±10%Current comsumption: Less than 110mAOperationg ambient temperature: -5 to 50Operating ambient humidity: Less than 90% RH (No condensing)Weight: Approx. 130gAccessories: Instruction manual
Terminal coverDetachable 6-P connector
(C Type) (N Type)
ASAHI KEIKI CO.,LTD.76
Tran
smitt
er
Input Specifications
Output Specifications (1st, 2nd output)
General SpecificationAccuracy: ±0.25% F.S (25˚C±2˚C)Temperature Characteristic: ±0.02% F.S/˚CResponse time: less than 50msec (0 to 90%)Insulation resistance: Between input and output 1, output 2, power
supply more than 100M Ω (500V DC)Dielectric strength: Between input and output 1, output 2, power
supply 1500V AC per 1 min.Power supply: 100 to 240V AC ±10%Operating temperature: –5 to 50˚C less than 90%RH (No
condensing)Power comsumption: Less than 45mA at 100V AC
Less than 30mA at 200V ACWeight: Approx. 130gAccessory: Instruction manual, terminal cover
Transmitter With Two OutputsTW-2XA
Featuers• DIN Rail m ount
• AC Power Supply 100 to 240V AC±10%
• 2 Outputs
Y specificationInput voltage: less than 250V DC min span 0.1V DCInput Curent: less than 50mA DC min. span 1mA DC
Special250 Ω
Input0 to 5V DC1 to 5V DC0 to 10V DC4 to 20mA DC
Input Resistance
more than 1M Ω
Code No.012AY
Special
Output signal0 to 5V DC1 to 5V DC0 to 10V DC4 to 20mA DC
Load Resistance
more than 2K Ω
more than 4K Ωless than 550 Ω
Code No.012AY
Y specificationOutput voltage: less than ±10V DC min. span 1V DCOutput Curent: less than 20mA DC min. span 1mA DC
Ordering Code
Dimensions
Connection Diagram
Block Diagram
TW-2XA- -1
Input
2nd output
1st output
0. 0 to 5V DC 1. 1 to 5V DC 2. 0 to 10V DC A. 4 to 20mA DC Y. Special
0. 0 to 5V DC 1. 1 to 5V DC 2. 0 to 10V DC A. 4 to 20mA DC Y. Special
0. 0 to 5V DC 1. 1 to 5V DC 2. 0 to 10V DC A. 4 to 20mA DC Y. Special
Front
96 to 98 Slide
94
64.5
20
35.4
17.4
41
4.3
48
Side
Output 1
Input
TW–2XA–XXX–1
Output 2
Power Supply(AC)
ZERO SPAN ZERO SPAN
Output 1 OutputCircuit 1
InputCircuit
InputCircuit
OutputCircuit 2
Input
Output 2
Power Supply
ASAHI KEIKI CO.,LTD.
Transmitter
77
InputSpecification
Output Specification
[1st output]
Y specification
[2nd output]
General SpecificationAccuracy: ±0.25% F.STemperature characteristic: ±200ppmF.S/˚C(TYP)Response time: less than 2 sec (0 to 90%)Insulation resistance: Between Input and output/power supply
more than 100M Ω (500V DC)Dielectric strength: Between Input and output/power supply
1500V AC per 1 min.Power supply: 100 to 240V AC ±10%
24V DC ±10%Power consumption: Less than 110mA at DC
Less than 50mA at ACOperating temperature: –5 to 50˚C less than 90%RH (No
condensing)Weight: Approx. 160gAccessory: Instruction manual, terminal cover, 6P
connector
Temperature Transmitter With Two OutputsTW-2C
Featuers• DIN Rail Mount
• AC Power Supply 100 to 240V AC ±10%
DC Power Supply 24V DC ±10%
• 2 Outputs
• Sensor Type: R,K,E,J,T,S,B,PT-100 Ω
SensorRKEJTSB
Pt 100 Ω
CodeRKEJTSBP
Input temperature0 to 1700˚C
–50 to 1200˚C–50 to 900˚C–50 to 1000˚C–50 to 350˚C0 to 1700˚C
200 to 1700˚C–150 to 800˚C
Minimum Span400˚C100˚C100˚C100˚C100˚C500˚C
1000˚C100˚C
Thermocouple Input SpecificationAccuracy of Cold Junction Compensation ±1˚C (10 to 30˚C)(For thermocouples other than B type thermocouple)
RTD lnput SpecificationAllowable leadwire resistance: Less than 10ΩCurrent following through RTD: 1mA
Ordering Code
Dimensions
Connection Diagram
Block Diagram
RKEJTSBP
0. 0 to 5V DC1. 1 to 5V DC2. 0 to 10V DCA. 4 to 20mA DC
A. 4 to 20mA DCY. special
1. 100 to 240 AC4. 24V DC
TW-2C- -
Input
2nd output
Power supply
1st output
35.4
41
20
94
96 to 98 Slide
64.5
17.4
42.4
4.3
Front
Side
TerminalCover
TW–2C
TCRTD
Input
PowerSupply
1st Output
2nd Output
Input MPU
(–)6
(–)5
(+)4
11
12
9(+)
7(+)
8(–)
Burnout Circuit
Cold Junction Compensation
10(–)
2ndOutputCircuit
1stOutputCircuit
Pow
er Supply
CodeAY
Output signal4 to 20mA DC
Output Load resistanceless than 550 Ω
Output at burnout
Approx. 120% F.SSpecial
Code Y
Output signal 0 to 5VDC 1 to 5VDC 0 to 10VDC
Output Load resistance
more than 2K Ω
more than 4K Ω
Output at burnout
Approx. 120% F.S
Code012A
Output signal0 to 5V DC1 to 5V DC0 to 10V DC4 to 20mA DC
Output Load resistance
more than 2K Ω
more than 4K Ωless than 550 Ω
Output at burnout
Approx. 120% F.S
ASAHI KEIKI CO.,LTD.78
Tran
smitt
er
DC voltage measurement
DC current measurement
Specification
Measuring SectionInput configuration : Single ended Conversion rate : 12.5times/sec (50Hz), 15times/sec (60Hz)Noise rejection ratio : NMR40dB or more (50/60Hz)Display : Red LED 8mm heightPolarity display : Automatic “-” display when the computation
result is minusOverrange warning : When input exceeds the maximum display,
display “o.L” or “-o.L”Maximum display : ± 9999 (4 digit)Decimal point : Settable to any digit positionZero display : Leading zero suppressionTemp. coeff. : ± 100ppm/˚C
Common SectionMemory backup : EEPROM (rewrite 100,000times)Operating temp. : 0 to 50˚C 35 to 85%RHStorage temp. : -10 to +70˚C less than 60%RHPower supply : 24V DC ± 20%Power consumption : 70mA (TYP) at 24V DCDimensions : 48mm (W) 98mm (H) 41mm (D)Weight : approx. 140g (unit only)Dielectric strength : Input (LO) and comparator output 500V DC
per min.Power supply (0V) and input (LO),comparator output case, 1500V AC per min.Input (LO) and case, 1500V AC per min.
Case material : Black PBTInsulation resistance : 500V DC 500M ohm or more as the above
terminalsExcitation supply : 24V DC ± 10% 25mA ripple less than
200mVp-pAccessories : Instruction manual. terminal cover,
connector
Comparison SectionControl method: Computation by microcomputerSetting range: -9999 to +9999Operating: By conversion rateComparison condition: Hi setpoint < Measured value →HI
Hi setpoint Measured value Lo setpoint →GOMeasured value < Lo setpoint →LO
Relay output capacity: 30V DC/1A resistive load125V AC/0.5A resistive load
Photo coupler output capacity: Voltage max. 30VCurrent max. 50mASaturation voltage less than 1.2V at 50mA
Digital Alarm SetterTW-3R
Featuers• DIN rail mount
• Hi and Lo setpoints
• Power supply 24V DC
Range Measurment012
0 to 5V1 to 5V0 to 9.999V
DisplayOffset ± 9999
Fullscale± 9999
Input Protection
± 250V
Input impedance1M Ω1M Ω1M Ω
Accuracy: ± (0.1% of rdg +2 digit) (23˚C ± 5˚C 35 to 85%RH)
Range Measurment
A 4 to 20mA
DisplayOffset ± 9999
Fullscale± 9999
Input Protection
± 60mA
Input impedance
50 Ω
Accuracy: ± (0.1% of rdg +2 digit) (23˚C ± 5˚C 35 to 85%RH)
Ordering Code
Dimensions
Connection Diagram
TW-3R-
Comparator output
Range
1. Relay 2. Photo Coupler
0. 0 to 5V DC 1. 1 to 5V DC 2. 0 to 9.999V DC A. 4 to 20mA DC
35.4
41
20
94
96~98 Slide
64.5
17.4
42.4
4.3
Front
Side
Terminal Cover
HI
GO
LO
EM
NCHI
LOInput
-
+
DC24V
TW–3R
Relay
0V
Photocoupler
NCNC
+24V
HI
COM
LOCC
e
ASAHI KEIKI CO.,LTD.
Transmitter
79
TransmitterTH-1X
Code No. Output signal Load resistancemore than 2KΩmore than 2KΩmore than 4KΩmore than 4KΩless than 550Ω
0123AY
DC 0 to 5 VDC 1 to 5 VDC 0 to 10 V
DC -10 to 10 VDC 4 to 20 mA
special
Special: Voltage input less than ±10 V DC, min span 1 VDCCurrent input less than 20 mA DC, min span 5 mA DC
Output specificationDC voltage & current
Ordering Code
Code No. Input signal Input resistance012345AY
DC 0 to 5 VDC 1 to 5 VDC 0 to 10 V
DC -10 to 10 VDC 0 to 1 V
DC 0 to 0.1 VDC 4 to 20 mA
special
more than 1MΩ
250Ω
Special: Voltage input less than 250 V DC, min span 0.1 VCurrent input less than 50 mA DC, min span 5 mA DC
Input specificationsDC voltage & current
TH-1X-
Input code
Output code
0. DC 0 to 5 V1. DC 1 to 5 V2. DC 0 to 10 V3. DC -10 to 10 V4. DC 0 to 1 V5. DC 0 to 0.1 VA. DC 4 to 20 mAY. special
0. DC 0 to 5 V1. DC 1 to 5 V2. DC 0 to 10 V3. DC -10 to 10 VA. DC 4 to 20 mAY. special
Features
・Easy to change input/output code (SJ)
・Slim width 12.5 mm
・DIN rail mount type
・24 VDC power supply
Dimensions
+ -
78
+ -
+ -
6
34
34
56
78
INPUT
SPAN
ZERO
TAG
TH-1X
MODEL
INPUT
OUTPUT
POWER
LOT No.
TAG No.
TH-IX-00
DCO~5V
DCO~5V
DC24V
0105A
OUTPUT
TOKYO JAPAN
ASAHI KEIKI
POWER
5
99±0.5
59±0.5
115±
0.5
(4)
4max
12.5
DIN rail
Front
Side
General specificationAccuracy: ±0.25% F.STemp. Coefficient: ±0.02% F.S/°CResponse Time: less than 20 msec (0 to 90%TYP)Insulated Resistance: input/output/power supply, more than 100MΩDielectric Strength: input/output/power supply, AC 1500V/1 min.Power Supply: 24 V DC±10%Power consumption: less than 60 mAOperating Temp.: -5 to 50°C less than 90%RHSize: 99 mm (H)×12.5 mm(W)×115 mm(D)
Connection Diagram
+
-
+
-
DC 24V
output
LOAD
input 4
3
6
5
8
7
ASAHI KEIKI CO.,LTD.80
Tran
smitt
erTemperature Transmitter
TH-1C
Code Output signal
0
1
2
A
DC 0 to 5 V
DC 1 to 5 V
DC 0 to 10 V
DC 4 to 20 mA
OutputLoad resistance
More than 2k Ω
More than 4k ΩLess than 550 Ω
Output at burnout
Approx 120% F.S
Output Specification
Ordering Code
Sensor Code Input temperature Minimum Span
R
K
E
J
T
S
B
Pt 100 Ω
R
K
E
J
T
S
B
P
0 to 1700°C-50 to 1200°C-50 to 900°C-50 to 1000°C-50 to 350°C0 to 1700°C
200 to 1700°C-150 to 800°C
400°C100°C100°C100°C100°C500°C1000°C100°C
Input Specification
TH-1C-
Input code 1.
2.
Output code
Accessory code
R. R Type (0 to 1700°C)K. K Type (0 to 1200°C)E. E Type (0 to 900°C)J. J Type (0 to 1000°C)T. T Type (0 to 350°C)S. S Type (0 to 1700°C)B. B Type (0 to 1700°C)
P. RTD Pt (0 to 800°C)
0. 0 to 5 VDC1. 1 to 5 VDC2. 0 to 10 VDCA. 4 to 20 mADC
0. No accessory provided1. Software and cable provided
As input specifications, separately specify the zero and span temperatures (in steps of 1°C).Otherwise, any one of the above temperatures is selected.When purchasing only the setting soft cable, specify "TH-1C-XX-1."
Example: TH-1C-K0-1 0 to 1000°C
Can change input sensor
Featuers
・Slim width 12.5mm
・DIN rail mount type
・Power supply 24VDC ±10%
・Input sensor
R,K,E,J,T,S,B, PT-100 ohm
Dimensions
990.5
590.5
115
0.5
(4)
4
12.5
0.5
0
DIN rail (35mm Wlde)
Front View
Side View
General SpecificationAccuracy: ±0.25% F.S (At 25±2°C)Temperature characteristic: ±0.02% F.S/°CPower supply voltage variation:±0.1% F.SResponse Time: Less than 2 sec (0 to 90%)Insulation resistance: Between input and output/power supply;
More than 100 MΩ at 500 VDCDielectric strength: Between input and output/power supply;
For 1 min. at 1500 VACPower supply voltage: 24V DC±10%Consuming current: Less than 60 mA (At 24 VDC)Operating ambient temperature: -5 to 50°COperating ambient humidity: Less than 90%RH (No-condensing)Storage temperature: -10 to 70°CStorage humidity: Less than 60%RH (No-condensing)Case material: Black PC risin 94V-2Weight: Approx. 80g
Connection Diagram
Note: Pay attention to the connection polarity.
2
1
4
3
6
5
8
7
2
1
4
3
6
5
8
7
Out
put s
igna
l
LoadDC
24V
Out
put s
igna
l
LoadDC
24V
T/C input
Pt input
B
A
B
Thermocouple Input SpecificationAccuracy of Cold Junction Compensation ±1°C (10 to 30°C)(For thermocouples other than B type thermocouple)
RTD Input SpecificationAllowable leadwire resistance: Less than 10 ΩCurrent following through RTD: 1mA
ASAHI KEIKI CO.,LTD.
Transmitter
81
TransmitterTH-41
Ordering Code
TH-41-
Number of channels 1. 1 channel2. 2 channel
Featuers
・Self-powered
・1ch or 2ch input
・Slim width 12.5mm
・DIN rail mount type
Dimensions
34
12
56
78
TAG
TH
-41
990.5
590.5
115
0.5
(4)
4max
12.5
0.5
0
DIN rail (35mm Wlde)
Front View
Side View
12
INPU
T1
34
INPU
T2
56
OUTP
UT2
78
OUTP
UT1
MOD
ELIN
PUT1
OUTP
UT1
INPU
T2 OU
TPUT
2LO
T No
.TA
G No
.
TH-4
1-2
DC4
20
mA
max
. 30V
30m
ADC
4
20m
ADC
4
20m
Am
ax. 3
0V 3
0mA
DC4
20
mA
0105
A
TOKY
O JA
PAN
ASAH
I KEI
KI
SpecificationsInput signal: 4 to 20mADCMax. input current 30mADCMax. output load: 1000 ohmsVoltage loss: less than 3VResponse time: 20ms (0 to 90%)Temperature characteristic: less than ±0.005%/°CAccuracy: ±0.1% F.SOperating temp.: -5 to 50 °COperating ambient humidity: less than 90%RH (no condensing)Storage temp.: -10 to 70°CWeight: Approx. 80gDielectric Strength: Between the input and output 2000VAC/1min.Insulation resistance: Between the input and output or power supply
more than 100M ohms (at 500 VDC)
Connection Diagram
2
1
4
3
6
5
8
7
Note: Pay attention to the connection polarity.
Inpu
t sig
nal C
H2
Inpu
t sig
nal C
H1
Out
put s
igna
l CH
1
Load
Load
Out
put s
igna
l CH
2
Operating ConditionWhen using the TH-41, pay attention to the following.The TH-41 can be used if the sum of voltage calculated by a voltageloss of 3V across the TH-41 and that of RA X 20mA across a loadconnected is smaller than the signal cource voltage.
Signalsource
LoadRA
TH-41VA
20 mA 20 mA
Voltage loss: 3V
VA 3V 20 mA RA
ASAHI KEIKI CO.,LTD.82
Tran
smitt
er
Input Specification
Output Specification
General SpecificationSetting range at factory: Input 1 to 5 V DC, Output 4 to 20mA DCAccuracy: ±0.25% F.S (25˚C±2˚C)After changed input range error:
±1% F.SAfter changed output range error:
±1% F.STemperature characteristic: ±0.02% F.S/˚CResponse time: less than 15ms (0 to 90%)(TYP)Insulation resistance: Between input and output/power supply
more than 100M ohm at 500V DCDielectric strength: Between input and output/power supply
1500V AC per 1min.Power supply: 24 V DC ±10%Power consumption: Less than 80mAOperating temperature: –5 to 50˚C Less than 90%RH (No
condensing)Weight: Approx. 80gApproval: EN61000-6-2, EN55011Accessory: Switch sheet
Ordering code
Programmable TransmitterTH-1M
Featuers• Can change input and output by front dip switch
• Power supply 24V DC
• DIN Rail mount
Input resistance
More than 1 MΩ
250 Ω
Input signal0 to 5V DC1 to 5V DC0 to 10V DC0 to 60mV DC4 to 20mA DC0 to 20mA DC
Output signal0 to 5 V DC1 to 5 V DC0 to 10 V DC4 to 20 mA DC0 to 20 mA DC
Allowable load resistanceMore than 2 k ΩMore than 2 k ΩMore than 4 k ΩLess than 550 ΩLess than 550 Ω
Setting or changing input/output range
Dimensions
Connection Diagram
Block Diagram
ONOFF
1 2 3 4
SW1 SW2
0-5V
1. Setting or changing input range
1-5V
0-10V
0-60mV
4-20mA
0-20mA1 2 3 4 5 6 7 8
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
1 2 3 4
SW1 SW2
0-5V
2. Setting or changing output range
1-5V
0-10V
4-20mA
0-20mA1 2 3 4 5 6 7 8
ONOFF
ONOFF
ONOFF
ONOFF
99±0.5
43
65
87SP
AN
ZE
RO
TA
GT
H-1
M
4max
12.5
+0.
5
–
0
59±0.511
5±0.
5
(4)
DIN RAIL
Front
Side
DC24V
OutputInput
3(+)
4(–) 6(–)
5(+)
8(–)
7(+)
ZERO SPAN
OutputCircuit
InputCircuit
Pow
er Supply
Circuit
Input Output
Isolation AMP
DC24V
TH-1M
ASAHI KEIKI CO.,LTD.
Transmitter
83
Ordering Code
Input specifications4-20mA DC (Input resistance 50Ω)
Output specifications
For code No. YLimit of specificationsVoltage output : Less than +10VDC and more than -10VDCMinimum span : 1VDCCurrent output : Less than 20mADCMinimum span : 5mADC
SpecificationsAccuracy : ±0.25%F.S (23˚C±2˚C) Temperature characteristic : ±200ppmF.S/˚C (TYP.)Response time : Less than 50 msec (0~90%)Insulated resistance : Between input and output/power supply;
More than 100MΩ (at 500V DC)Dielectric strength : Between input and output/power supply;
For 1 min. at 2000VACPower supply voltage : 24V DC±10% less than 80mAOperating ambient Temp. : -5 to +50˚COperating ambient humidity : Less than 90%RH(No-condersing)Weight : Approx. 80g
Powerr supply to 2-wire transmitterOutput voltage : 24~32VDC (No load resistance)Current Capacity : Less than 22mADCCurrent at short circuit : Less than 30mADCPermissible : Short circuit duration : No limit
Dimensions
Connection Diagram
Block Diagram
DISTRIBUTORTZ-5L
Features• DIN rail mount
• Low cost
• Miniature Size
• Isolated Input/Output/Power supply
Output code
Input code
0: DC 0~5V1: DC 1~5V2: DC 0~10VA: DC 4~20mAY: Special
DC 4~20mA
TZ-5L-A
Circuit
Power Supply Circuit
IsolationAMP
Output
DC24V
Output
5(+)6(ー)
7(+)
8(ー)
3(ー)
1(+)
4(–)
2(+)
ExcitationPowerSupply
Zero Span
Input
InputCircuit
012AY
DC0~5VDC1~5VDC0~10VDC4~20mA
Other than the above
Output signal
more than 2KΩ
more than 4KΩless than 550Ω
Load resistanceCode No.
5 max94
54
63
11.5
25
25.5
Side
Front
83
34.5 41
2-W
ireT
rans
mitt
er
Out
put S
igna
l
DC24V6 842
5 731
LOA
D
Note : Pay attention to the connection polarity.
ASAHI KEIKI CO.,LTD.84
Tran
smitt
er
Input Specifications
Output Specifications
General SpecificationsAccuracy: ±0.25% F.S.Temp. Coefficient: ±200 ppm/°C F.S(Typ)Response Time: Less than 50msec(0 to 90%)Insulated Resistance: Input/Output/Power supply more than
100MΩ(500VDC)Dielectric Strength: Input/Output/Power supply 2000VAC/l minPower Supply: 24VDC ±10% less than 60mAOperating Temp: -5~+50°C, less than 90%RHWeight: 80g
012ABY
DC0~5VDC1~5VDC0~10VDC4~20mADC0~20mA Special
Output signal
more than 2KΩ
more than 4KΩ
less than 550Ω
Input resistanceCode No.
*Code "Y" specificationsVoltage output: less than ±10VDC (span 1VDC)Current output: less than 20mADC (span 1mADC)
012ABY
DC0~5VDC1~5VDC0~10VDC4~20mADC0~20mA Special
Input signal
more than 1MΩ
250Ω
Input resistanceCode No.
*Code "Y" specificationsVoltage input: less than 250VDC (span 100mVDC)Current input: less than 50mADC (span 1mADC)
TERMINAL TYPE TRANSMITTERTZ-5H
Features• Miniature size
• DIN rail mount
• Power supply 24V DC
• Easy connection
Side
Front
98
9454
63
11.5
25
2 4 6 8
5 71 3
83
25.5 34
.5 41
INPUTOUTPUTDC24V
6 842
5 731
LOA
D
Circuit
Power Supply Circuit
IsolationAMP
Output
DC24V
Output
5(+)6(ー)
7(+)
8(ー)
4(ー)
1
2
3(+)
N.C
Zero Span
Input
InputCircuit
Block Diagram
Connection Diagram
Dimensions
TZ-5H-
Output code
Input code
0. 0~5VDC1. 1~5VDC2. 0~10VDCA. 4~20mADCB. 0~20mADCY. Special
0. 0~5VDC1. 1~5VDC2. 0~10VDCA. 4~20mADCB. 0~20mADCY. Special
Ordering Guide
ASAHI KEIKI CO.,LTD.
Transmitter
85
TERMINAL TYPE TRANSMITTERTZ-5X
Features
• DC Power supply 24VDC
• DIN rail mounting
• Input / Output / Power supply isolated
Output SignalDC 0 to 5VDC 1 to 5VDC 0 to 10VDC –10 to 10VDC 0 to 4VDC 4 to 20mA
Output load resistance
more than 2 kΩ
more than 4 kΩ
more than 2 kΩless than 550 Ω
Code No.01236AY Special
Special Voltage output: DC -10 to 10V span DC 1VCurrent output: DC 0 to 20mA span DC 1mA
Output specifications
Ordering CodeInput Signal
DC 0 to 5VDC 1 to 5VDC 0 to 10VDC –10 to 10VDC 0 to 1VDC 0 to 0.1VDC 0 to 4VDC 0 to 20VDC –2 to 2VDC –5 to 5VDC 4 to 20mADC 0 to 20mA
Allowable input
–50 to +150%F.S
Input Resistance
more than 1MΩ
250Ω
Code No.0123456789ABY Special
Special Voltage input: DC less than 250V span 0.1VCurrent input: DC less than 50mA span DC 1mA
Input specifications
0. DC 0 to 5V1. DC 1 to 5V2. DC 0 to 10V3. DC –10 to 10V6. DC 0 to 4VA. DC 4 to 20mAY. special
0. DC 0 to 5V1. DC 1 to 5V2. DC 0 to 10V3. DC –10 to 10V4. DC 0 to 1V5. DC 0 to 0.1V6. DC 0 to 4V7. DC 0 to 20V8. DC –2 to 2V9. DC –5 to 5VA. DC 4 to 20mAB. DC 0 to 20mAY. special
Output
Input
TZ-5X-
DC24V
++
–––
+12
34
56
78
Inpu
t Sig
nal
Load
Out
put S
igna
l
Caution: Be polarity careful
Connection Diagram
3(+)
4(–)
ZERO SPAN
2
1
8(–)
7(+)DC 24V
5(+)
6(–)
NC
Input Signal InputCircuit
Isolation AMP
OutputCircuit
Powe
r Sup
ply Ci
rcuit
Output Signal
Block Diagram
Dimensions
Front
Side
94
25
57.6
35.2
37.3
40.8
9847
1
2
3
4
5
6
7
8
Terminal Cover
Slide Bar
General specificationsAccuracy: ±0.1% F.S (25˚C±2˚C)Temp. Coefficient: ±200PPM F.S/˚C (TYP)Response time: less than 50msec (0 to 90%)Insulated Resistance: input/output/power supply, more than 100MΩDielectric strength: input/output/power supply, AC2000V/1 min.Power supply: 240VDC±10%Power consuption: less than 65mA (at 24VDC)Operating Temp: -5 to 50˚C
Less than 90% RHCase Material: Black ABSWeight: Approx. 80g
ASAHI KEIKI CO.,LTD.86
Tran
smitt
erTERMINAL TYPE TRANSMITTER
Ordering Code
TZ-41
Dimensions
Connection Diagram
Block Diagram
SpecificationsSignal Input: 0 to 20mA,4 to 20mA or0 to 5mASignal Output: 0 to 20mA, 4 to 20mA or 0 to 5mAInput Current: Max. 30mALoad: Max. 600ΩVoltage loss between input and output: Approx. 3.3VOutput Ripple: Less than 0.5% (20mA at 250W)Temp, Coefficient: Less than ±100PPM/°CAccuracy: ±0.1% (23°C±1°C) at 250W loadAdditional Error: +0.1%/100W at load,250W
-0.1%/100W at load.250WOperating Temp: -5 to +50°C, less than 90% RHMechanical Design: Type of snap mount on DIN railInsulated Resistance: More than 100MW at 500VDC between input
and outputDielectric Strength: 1 min. at 2kVAC between input and outputWeight: Approx. 80g
INPUT/OUTPUTTZ-41 is designed as "Self Powered Isolation" and transformation ratio is1:1. Input current is 0 to 20mA, but customers can use input currentranges 0 to 5mA, 0 to 20mA or 4 to 20mA.Having 1:1 isolation the output current will of course be the same as theinput current, e.g., 0 to 5mA, 0 to 20mA, 4 to 20mA.TZ-41 will provide 0 to 5V or 1 to 5V output.
Output load and AccuracyPlease note the TZ-41 can operate into a load of up to 600W. Accuracyis a function of load resistance. Standard accuracy is +/- 0.1% with a250W load and ambient temp. of 23±1°C. For loads other then 250Waccuracy changes as shown below.
Example load 450ΩStandard accuracy: ±0.1%Additional error (+200W): ±0.1% - 0.2%=-0.1% to -0.3%
(-0.1%/100Ωatload>250Ω)
TZ-41
1
2
3(+)
4(-)
N.C
N.C
N.C
N.C
5(+)
6(-)
7
8
Output Output
Chopper Oscillation Circuit
RectifierCircuit
Features
• Miniature Size
• Self-powered
• Easy Connection
• DIN rail mount
11.5
25
63
54
94
98
83
1 3
2 4
5 7
6 8
25.5
34.5 41
Front
Side
1234
5678
Input Output
LOA
D
DC0~20mA(4~20mA)
ASAHI KEIKI CO.,LTD.
Transmitter
87
General SpecificationsAccuracy: ±0.25% F.STemp. Coefficient: ±200ppm/˚C (Typ.)Response Time: Less than 80mS (0~90%) (Typ.)Dielectric Strength: Input/Output/Power supply AC2000V/1 min.Insulated Resistance: Input/Output/Power supply more than
100MΩ at DC500VOperating Temp.: -5~50˚CPower Supply: DC24V±10% less than 55mABurn Out: Upper side
TERMINAL TYPE TRANSMITTERTZ-5A
Ordering Code
Features
•Isolated Input/Output/Power supply
•DIN rail mount
•Input RTD sensor
TZ-5A-
Output Code
Input Code
1. 0~100°C2. 0~200°C3. 0~300°C4. 0~400°C5. 0~500°C6. 0~600°CY. Special
1. DC 1~5V2. DC 4~20mA3. DC 0~10VY. Special
Input SpecificationsPT-100 Ω three wires less than 20Ω
123456
Y
0 to 100°C0 to 200°C0 to 300°C0 to 400°C0 to 500°C0 to 600°CSpecial (0~600°C)(Span more than 100°C)
Temp. RangeCode No.
123
Y
1~5V4~20mA0~10VSpecial (Current 20mA)(Voltage less than ±10V)
Temp. RangeCode No.
Allowable Load: More than 2KΩ(At 1 to 5V)Resistance More than 4KΩ(At 0 to 10V)
Less than 550Ω(At 4 to 20mA)
Output SpecificationsDC voltage or current
Dimension
Connection Diagram
Block Diagram
98
9454
2541
2 4 6 8
5 71 3
Input
Pt100Ω
Output1 3 5
2 4 6
7
8
A
B BLO
ADDC
24V
Circuit
Power CircuitBurn-out Circuit
Input Circuit
IsolatedAmplifier
Constant Current Circuit
Output
DC24V
Output
+5ー6
+7
ー8
RTD
3
2
1
4
N.C
Span Zero
ASAHI KEIKI CO.,LTD.88
Tran
smitt
er
Input SpecificationsPotentiometer (100 to 10KΩ)
Output SpecificationsDC voltage or current
General SpecificationsAccuracy: ±0.25%F.ScTemp. Coefficient: ±200ppm/˚C (Typ.)Response Time: Less than 50mS (0~90%) (Typ.)Dielectric Strength: Input/Output/Power supply AC2000V/1 min.Insulated Resistance: Input/Output/Power supply more than
100MΩ at DC500VOperating Temp.: -5~50˚CPower Supply: DC24V +15%,-5% less than 55mAZero Adjustment Range: 0~10%Span Adjustment Range: 90~100%Reference Voltage: 0.5V
TERMINAL TYPE TRANSMITTERTZ-5B
Ordering Guide
Features
•Isolated Input/Output/Power Supply
•DIN Rail mount
•Input Potentiometer
TZ-5B-
Output Code
DC 1 to 5VDC 4 to 20mADC 0 to 10VY. Special
123Y
1~5V4~20mA0~10VSpecial
Temp.RangeCode No.
Special Current Output Range: Less than 20mA (Min. span 1mA)Special Voltage Output Range: Less than ±10V (Min. span 1V)
Allowable Load: More than 2KΩ(At 1 to 5V)Resistance More than 4KΩ (At 0 to 10V)
Less than 550Ω (At 4 to 20mA)
Dimension
98
9454
2541
2 4 6 8
5 71 3
Connection Diagram
Block Diagram
Input
Potentionmeter
Output1 3 5
2 4 6
7
8
A
B
LOA
DDC24V
Power CircuitInput Circuit
IsolatedAmplifier
Constant Voltage Circuit
DC24V+7
ー8
3
2
1
4
N.C
Pot
entio
nmet
er
OutputOutput Circuit
+5ー6
Span Zero
ASAHI KEIKI CO.,LTD.
Transmitter
89
TERMINAL TYPE TRANSMITTERTZ-5C
Features
•Input K sensor
•Isolated input/output/power supply
•DIN rail mount
•Small size and easy installation
Input SpecificationsSensor type K
Output SpecificationsDC voltage or current
General SpecificationsAccuracy: ±0.4% F.STemp. Coefficient: ±300ppm/˚C F.S (TYP.)Response Time: Less than 0.5sec (0~90%) (TYP.) Load Resistance: DC1~5V more than 2kΩ
DC4~20mA Less than 550ΩDC0~10V more than 4kΩ
Insulated resistance: Input/output/power supply more than100MΩ(DC500V)
Dielectric Stregth: Input/output/power supply AC2000V/1min.Power Supply: DC24V+15%,
-5%Power Consumption: Less than 60mAOperation Temp: -5~50˚Cless than 90%RHCold Junction Compensator: ±1˚C at 20˚C±10˚C
12Y
0 ~ 500°C 0 ~ 1000°C Special(0 ~ 1000°C)Span(300 ~ 1000°C)
Temp. rangeCode No.
123Y
DC 1~5VDC 4~20mA DC 0~10VSpecial(Current less than 20mA)(Voltage less than ±10V)
OutputCode No.
Ordering Guide
TZ-5C-
Output
Input1. 0~500°C2. 0~1000°CY. Special
1. DC 1~5V2. DC 4~20mA3. DC 0~10VY. Special
Dimension
98
9454
2541
Side
Front
DIN RAIL2 4 6 8
5 71 3
Connection Diagram
Block Diagram
OUTPUT1 3 5
2 4 6
7
8LO
ADDC
24V
TCJ Senser+
-K Sensor
Circuit
Power Supply Circuit
Input Circuit
IsolationAMP
Output
DC24V
Output
+5ー6
+7
ー8
4
2
1
3
N.C
N.C
Span Zero
Input
Burn out
Cold junctionCompensation
Circuit
+
ー
Sensor
ASAHI KEIKI CO.,LTD.90
Tran
smitt
erTERMINAL TYPE TRANSMITTER
TZ-5D Features
• Input AC current(True-RMS)
• Isolated input/output/power supply
•DIN rail mount
•Small size and easy installation
Input /Output Specification
General SpecificationsAccuracy: ±0.1% F.SInput Frequency: 40Hz~1kHzTemp. Coefficient: ±200ppm/˚C (Typ.)Response Time: Less than 0.5sec (0~90%) Power Supply: DC24V+15% less than 55mA
-5%Operation Temp: -5~50˚C less than 90%RHInsulated Resistance: Input/output/power supply more than
100MΩ(DC500V)Dielectric Strength: Input/output/power supply AC1500V/1min.
123456Y
AC 0~1AAC 0~1AAC 0~1AAC 0~5AAC 0~5AAC 0~5A
Special
Intput
DC 1~5VDC 4~20mADC 0~10VDC 1~5VDC 4~20mADC 0~10V
OutputCode No.
Special AC current input: Less than 0~5A,Min span AC1A DC current output: Less than DC20mA,Min span DC1mA DC voltage output: Less than DC±10V,Min span DC1V Load resistance: DC 1~5V more than 2kΩ
DC 0~10V more than 4kΩDC 4~20mA less than 550Ω
Dimension
98
9454
2541
Side
Front
DIN RAIL2 4 6 8
5 71 3
Connection Diagram
Block Diagram
INPUT OUTPUT1 3 5
2 4 6
7
8
LOA
DDC24V
Circuit
Power Supply Circuit
Output
DC24V
Output
+5ー6
+7
ー8
3
2
1
4
N.C
SpanZero
Input
RMS CircuitC/T Isolation
Output InputTZ-5D-DC 1~5VDC 4~20mADC 0~10VDC 1~5VDC 4~20mADC 0~10V
1. AC 0~1A2. AC 0~1A3. AC 0~1A4. AC 0~5A5. AC 0~5A6. AC 0~5AY. Special
Ordering Guide
ASAHI KEIKI CO.,LTD.
Transmitter
91
TERMINAL TYPE TRANSMITTERTZ-5E
Features
•Input AC voltage
•Isolated input/output/power supply
•Power supply DC24V
•DIN rail mount
•Small size easy installation
Input Specifications
Output Specifications
General SpecificationsAccuracy: ±0.1% F.STemp. coefficient: ±200ppm/˚C F.S (Typ.)Response time: 70mS (Typ) 0~90%Input frequency: 40H~1KHzDielectric stregth: Input/output/power supply AC2000V/l min.Insulated resistance: Input/output/power supply more than 100MΩ
at DC500VOperating temp.: -5˚C~50˚C (less than 90% RH)Power supply: DC24V -5%, +10%
567Y
AC 0~35VAC 0~110VAC 0~150VSpecial
InputCode No.
Special specification Voltage: less than AC300V, min span AC4V
123Y
DC 1~5VDC 4~20mADC 0~10V
Special
Output
More then 2kΩ More then 550Ω More then 4kΩ
Load resistanceCode No.
Special specification Current: less than 20mA,min span 1mA Voltage: less than ±10V,min span 1V
Dimension
98
9454
2541
Side
Front
DIN RAIL2 4 6 8
5 71 3
Connection Diagram
Block Diagram
AC OUTPUT1 3 5
2 4 6
7
8
LOA
DDC24V
Circuit
Power Supply Circuit
IsolationAMP
Output
DC24V
Output
+5ー6
+7
ー8
3
2
1
4
N.C
Span Zero
Input
RMSConversion
TZ-5E-
Output
Input
5. AC 0~35V6. AC 0~110V7. AC 0~150VY. Special
1. DC 1~5V2. DC 4~20mA3. DC 0~10VY. Special
Ordering Guide
ASAHI KEIKI CO.,LTD.92
Tran
smitt
er
Dimension
98
9454
2541
Side
Front
DIN RAIL2 4 6 8
5 71 3
TERMINAL TYPE TRANSMITTERTZ-5F
Features
•Input small current and voltage
•Isolated input/output/power supply
•Power supply DC24V
•DIN rail mount
•Small size and easy installation
Input Specifications
Output Specifications
General SpecificationsLoad resistance: More than 2KΩ( at 1~5V)
More than 4KΩ( at 0~10V)Less than 550Ω( at 4~20mA)
Accuracy: ±0.25% F.STemp. coefficient: ±200ppm/˚C F.S (Typ.)Response time: Less than 0.1sec 0~90%Dielectric stregth: Input/output/power supply AC2000V/l min.Insulated resistance: Input/output/power supply more than 100MΩ
at DC500VOperating temp.: -5˚C~50˚C (less than 90% RH)Power supply: DC24V -5%, +15%
123Y
DC 0~10mVDC 0~50mVDC 0~100µASpecial
InputCode No.
Special specification Current: less than 1mA, min span 10µA Voltage: less than 100V, min span 5mV
123Y
DC 1~5V DC 4~20mADC 0~10VSpecial
OutputCode No.
Special specification Current: less than 20mA, min span 1mA Voltage: less than ±10V, min span 1V
Connection Diagram
Block Diagram
INPUT OUTPUT1 3 5
2 4 6
7
8
LOA
DDC24V
Circuit
Power Supply Circuit
Input Conversion
IsolationAMP
Output
DC24V
Output
+5ー6
+7
ー8
4
1
2
3
N.C
Span Zero
Input
Ordering GuideTZ-5F-
Output
Input
1. DC 0~10mV2. DC 0~ 50mV3. DC 0~100μAY. Special
1. DC 1~5V 2. DC 4~20mA 3. DC 0~10VY. Special
ASAHI KEIKI CO.,LTD. 93
DIGITAL PANEL METERACCESSORIES
Shunt Resistor (20A, 60A)
20A/200 mV±0.5%
60A/ 60 mV±0.5%
Power Supply
Splash Proof Cover (WP)
• Dimensions 59 mm(H) エ 170 mm(W) エ 18 mm(D)
• Dust-proof and water proof
• Available bracket installation 1/8 DIN case
IP66 COVER (WP-3)
80 2-4.1×6φ
6
5
4
1
2
3 37
+5V
DVNC
AC100VG
ND4543
30
69±0.5
Model No. Input voltage Output voltage Output current
APS-250-1
APS-250-2
APS-240-1
APS-240-2
90~132VAC
180~264VAC
90~132VAC
180~264VAC
4.85~5.15V
24V±10%
Max 250mA
80mA
(Input voltage is selectable internal switch)
140
Fittng hole distance 120mm
Height 50
107
59
ASAHI KEIKI CO.,LTD.94
MODEL RANGE DIVIDE RATIO RESOLUTIONINTERNALRESISTANCE
MAX. INPUTVOLTAGE
ACCURACYTEMPERATURECOEFFICIENT
ADV-501-12ADV-501-13ADV-501-14ADV-501-15
± 2V± 20V± 200V±2000V
1/101/1001/10001/10000
1mV10mV
100mV1V
1MΩ10MΩ10MΩ
100MΩ
less than ± 200V± 750V± 750V±2500V
less than 0.1%0.1%0.1%0.1%
± 50PPM± 50PPM± 50PPM±100PPM
MODEL RANGE DIVIDE RATIO RESOLUTIONINTERNALRESISTANCE
MAX. INPUTVOLTAGE
ACCURACYTEMPERATURECOEFFICIENT
ADV-502-14ADV-502-15
± 200V±2000V
1/1001/1000
100mV1V
10MΩ100MΩ
less than ± 750V±2500V
less than 0.1%0.1%
± 50PPM± 100PPM
MODEL RANGE RESOLUTIONINTERNALRESISTANCE ACCURACY
ASH-400-19ASH-400-20ASH-400-21ASH-400-22ASH-400-23ASH-400-24ASH-400-25ASH-400-26
±1.999µA±19.99µA±199.9µA±1.999mA±19.99mA±199.9mA
±1.999A±5.00A
100kΩ10kΩ1kΩ
100Ω10Ω1Ω
0.1Ω 0.01Ω
1nA10nA
100nA1µA
10µA100µA
1mA10mA
± 1%±1digit±0.5%±1digit±0.2%±1digit±0.2%±1digit±0.2%±1digit±0.3%±1digit±0.3%±1digit
±1%±1digit
INPUT MAX.CURRENT
less than±1mA± 5mA± 10mA± 50mA±150mA±500mA
±3A±8A
DIGITAL PANEL METERACCESSORIES
VOLTAGE DIVIDER
・FOR USE 0.2V RANGE(11 Range)
DIMENSIONS CONNECTION DIAGRAM
・FOR USE 2V RANGE(12 Range)
SHUNT
・FOR USE 0.2V(11 Range)
June 2004(KS)
DIG
ITAL PA
NEL M
ETER, TRASM
ITTER CATA
LOG
UE
2004
33-6, YAGUCHI 2-CHOME, OHTA-KU,TOKYO 146-8505, JAPANFAX :(03)3757-2989PHONE :(03)3579-3893E-mail :[email protected]
We reserve the right to change specifications without notice.