    Smart Solutions that Deliver ReliablePower Everyday --- Everywhere

    Through our commitment to research anddevelopment, we continue to develop smartsolutions for safe, reliable, environmentally friendlyelectrical power delivery. This Specifiers Guidecontains all the information necessary to order whatyou need to complete your projects for 5 kV 35 kV

    electrical distribution systems.

    Let our Legacy Speak For Itself

    From the Electric Century to theInformation Age

    Even a visionary like Thomas A. Edison could nothave imagined the sophistication required of electricaltransmission and distribution equipment a little morethan a century after the invention of the incandescentelectric light bulb and the beginning of the ElectricCentury. Nor could he have anticipated all of thecomplex issues facing the electrical industry today.

    Since its beginning, Cooper Power Systems hascontinued the commitment of its forebears toinnovation. Our research and development lab,the Thomas A. Edison Technical Center, embodiesEdisons philosophy of finding a better way withinnovative products that promote better power quality,reliability, safety, performance, and environmentalstewardship. Were proud to trace our heritage backto the industrys pioneer.

    Thomas A. Edison, Incorporated, one of ThomasEdisons original companies founded in 1910 and withcorporate roots that go back to 1889, combined withMcGraw Electric Company in 1957 to form McGraw-Edison. In 1985, McGraw-Edison became part of

    Cooper Power Systems. When RTE was acquired byCooper Industries in 1988 and merged with McGraw-Edison Power Systems, Cooper Power Systems wasformed. Coopers product offerings expanded againthrough the acquisition of Kearney in 1997. WhenRTE received a patent on the 15 kV loadbreak elbowdesign in 1966, its potential growth was probablyunrealized at the time. It is estimated that there arewell over 10,000,000 such elbows in service today.As a leading innovator in the industry, Cooper PowerSystems continues to introduce new products forunderground distribution systems. Other innovativecompanies have played key roles in the developmentof modern distribution systems, and they have

    helped Cooper Power Systems become a leadingmanufacturer of electrical distribution equipment.

    Table of Contents PageStandard Interfaces For Separable

    Connectors and Components 4

    Certified Tests and Performance 5

    Conductor Sizing 6

    AEIC Insulation Diameter Chart 8

    ICEA Insulation Diameter Chart 9200 A Loadbreak Connectors 10

    200 A Deadbreak Connectors 14

    200 A Stacking Dimensions 16

    600 A Deadbreak Connectors 18

    600/900 A Components &

    Replacement Parts 20

    600/900 A Connector Systems 22

    600 A Stacking Dimensions 24

    Splices 26

    Underground Surge Arresters 28

    Tools & Maintenance 30

    Bushings 34

    Fusing 36MagneX Single-Phase Interrupter 38

    MagneX Three-Phase Interrupter 40

    Faulted Circuit Indicators 42

    Sectionalizing Cabinets 46

    Part Number Index 48

    Support Available When You Need It 50

    Product Application Overhead and

    Underground Distribution Systems 52

    Choose Cooper Power Systems for Your Complete Project Needs

    2 Specifiers Guide: Components Master Catalog

    Theres a way to do it better find it.

    Thomas A Edison

  • 8/10/2019 Catalogo Power System

    3/56

    But Wait, Theres More

    In addition to rubber goods, we alsosupply surge arresters, tools, hotsticks,connectors, bushings, fusing, faultedcircuit indicators, sectionalizingequipment and more. Now, you can getall of your products in one place fromone manufacturer Cooper Power

    Systems! If you need more detail thanwhat is contained in this easy to useSpecifiers Guide, we have additionalinformation available on the internetat www.cooperpower.com. You canalso register to have access to CooperPower Systems complete online catalog,product and service literature that isupdated daily! You can view documentsin real time as they are updated. Toregister, go to www.cooperpowercentral.com.

    Technical Support When YouNeed It

    If you cannot find what youre lookingfor, or need more detailed information,please contact technical supportvoicemail at 800-847-4584 (withindomestic USA), or email your questionsto [email protected] support and applicationinformation are readily available. CooperPower Systems can also providepractical, hands-on training usingactual products so you can learn theeasiest way to fit our products into yourapplication.

    Quality PolicyEmployees of Cooper Industries arecommitted and empowered to provideproducts and services that exceedour internal and external customers'expectations. We work together toachieve world-class quality with relentlessdrive for continuous improvement.ISO 9001-2000 supports our ongoingcommitment to quality by strengtheninginternal processes and procedures.Commitment to quality assists us inensuring that our customers are delighted.

    Cooper Power Systems

    Following is additional information available to you from a variety ofresources.

    Cooper Power Systems Websitewww.cooperpower.com

    Additional Industry Websites

    IEEEindustry standardshttp://www.ieee.org/web/standards/home/index.html

    IEEE

    http://www.ieee.org

    Specific energy statistics from the U.S. governmenthttp://www.eia.doe.gov/

    U.S. Department of Energyhttp://www.energy.gov/

    3

  • 8/10/2019 Catalogo Power System

    4/56

    The following diagram specifies the IEEE Std 386 standardnterfaces supplied by Cooper Power Systems for variouspplications to ensure interchangeability of any matingomponents.

    Standard Interfaces for Separable Connectors and Components

    17.7

    8-23 .11

    MM

    LE215

    B

    100-.910

    IN

    200 A Loadbreak

    8.3 kV/14.4 kV

    200 A Loadbreak15.2 kV/26.3 kV

    200 A LoadbreakInterface 1A

    21.1 kV/36.6 kV(Large Interface)

    BOL-T15.2/26.3 kV

    BOL-T

    21.1/36.6 kV

    200 A Deadbreak8.3/15.2 kV

    200 A Bushing Well

    8.3 kV and 15.2 kV

    200 A Loadbreak15 kV Connector

    200 A 15 kV BushingWell Insert

    200 A Bushing Well15/25 kV

    Transformer orSwitching

    Apparatus

    200 A 25 kV BushingWell Insert

    200 A Loadbreak

    25 kV Connector

    200 A Loadbreak35 kV Connector

    200 A Deadbreak Connector

    15 kV and 25 kV

    600 A DeadbreakConnector

    15 kV and 25 kV(T-OP II Shown)

    600 A DeadbreakConnector 35 kV(T-OP II Shown)

    600 A DeadbreakBushing 35 kV

    600 A DeadbreakBushing 15/25 kV

    200 A Three-Phase Integral35 kV Loadbreak Bushing

    nterface Description Per IEEE Std 386 2006 standard

    Interface Interface

    BT-TAP8.3/14.4 kV and

    15.2/26.3 kV

    T-OP II8.3/14.4 kV and

    15.2/26.3 kV

    BT-TAP21.1/36.6 kV

    T-OP II21.1/36.6 kV

    Standard Interfaces for Separable Connectors and Components

    4 Specifiers Guide: Components Master Catalog

    Standard Interfaces for Separable Connectors and Components

  • 8/10/2019 Catalogo Power System

    5/56

    Certified Tests and Performance

    Cooper Power Systems Connectors, Splices,Underground Surge Arresters, Tools, Bushings,Fusing, Faulted Circuit Indicators and SectionalizingEquipment have been designed and tested perapplicable portions of Institute of Electrical andElectronics Engineers, Inc. (IEEE), AmericanNational Standards Institute (ANSI), NationalElectrical Manufacturers Association (NEMA) andother industry standards including:

    n IEEE Std 386standard for Separable

    Connectors

    n IEEE Std 404standardfor Cable Joints and

    Splices

    n IEEE Std C62.11standardfor Metal Oxide

    Surge Arresters

    n IEEE Std C37.41standard for Current-Limiting

    Fuses

    n IEEE Std 592standardfor Exposed

    Semi-conducting Shields

    nANSI C119.4Standardfor Copper and

    Aluminum Conductor Connectors

    n

    AEIC CS5, CS6and CS8 Standardsfor XLPand EPR Insulated Cables

    n ICEA S-94-649Standardfor XLP and EPR

    Insulated Cables

    Cooper Power Systems Separable Connectorsare rated for 15 kV, 25 kV and 35 kV systems inaccordance with the following ratings.

    Voltage Ratings 15 kV 25 kV 35 kV

    Standard Voltage Class 15 25 35

    Maximum Rating Phase-to-Phase

    14.4 26.3 36.6

    Maximum Rating Phase-to-Ground

    8.3 15.2 21.1

    AC 60 Hz 1 MinuteWithstand

    34 40 50

    DC 15 Minute Withstand 53 78 103BIL and Full Wave Crest 95 125 150

    Minimum Corona VoltageLevel

    11 19 26

    Current Ratings 15 kV 25 kV 35 kV

    Continuous 200 A rms 200 A rms 200 A rms

    Switching 10 make/breakoperations at200 A rms at14.4 kV

    10 make/breakoperations at200 A rms at26.3 kV

    10 make/breakoperations at200 A rms at36.6 kV

    FaultClosure

    10,000 A rmssym. at 14.4 kVfor 0.17s after10 switchingoperations

    10,000 A rmssym. at 26.3 kVfor 0.17s after10 switchingoperations

    10,000 A rmssym. at 36.6 for 0.17safte10 switchingoperations

    Short Time 10,000 A rms

    sym. for 0.17s3,500 A rms sym.for 3.0s

    10,000 A rms

    sym. for 0.17s3,500 A rms sym.for 3.0s

    10,000 A rms

    sym. for 0.173,500 A rms symfor 3.0s

    200 A Loadbreak Connector Ratings in Accordance with IEEE Std 386 stan

    Voltage Ratings and Characteristics

    Description Voltage

    Standard Voltage Class (kV) 15 25 35

    Maximum Rating Phase-to-Ground (kV rms) 8.7 14.4 20.2

    AC 60 Hz 1 Minute Withstand (kV rms) 35 52 69

    DC 15 Minute Withstand (kV) 70 100 125

    BIL and Full Wave Crest (kV peak) 110 150 200

    Minimum Corona Voltage Level (kV) 13 22 31

    Splice Voltage Ratings in Accordance with IEEE Std404 standard

    Splice Current Ratings in Accordance withIEEE Std 404 standard

    Current Ratings and Characteristics

    Description Amperes

    Continuous Equal to the current rating ofthe cable per

    IEEE Std 404 standard

    Short Time Equal to the current rating ofthe cable perIEEE Std 404 standard

    Voltage Ratings 15 kV 25 kV 35 kV

    Standard Voltage Class 25 25 35

    Maximum Rating Phase-to-Ground

    15.2 15.2 21.1

    AC 60 Hz 1 MinuteWithstand

    40 40 50

    DC 15 Minute Withstand 78 78 103

    BIL and Full Wave Crest 125 125 150

    Minimum Corona Voltage

    Level

    19 19 26

    Current Ratings 15 kV 25 kV 35 kV

    600 A Interface**

    Continuous 600 A rms 600 A rms 600 A rms

    24 HourOverload

    1,000 A rms 1,000 A rm 1,000 A rms

    Short Time 25,000 A rms

    sym. for 0.17 s10,000 A rms

    sym. for 3.0 s

    25,000 A rms

    sym. for 0.17 s10,000 A rms

    sym. for 3.0 s

    25,000 A rms

    sym. for 0.1710,000 A rms

    sym. for 3.0

    200 A Interface On Loadbreak Reducing Tap Plug (LRTP)*

    Continuous 200 A rms 200 A rms 200 A rms

    Switching 10 make/breakoperations at200 A rms at14.4 kV

    10 make/breakoperations at200 A rms at26.3 kV

    10 make/breakoperations at200 A rms at36.6 kV

    FaultClosure

    10,000 A rmssym. at 14.4 kVfor 0.17s after10 switchingoperations

    10,000 A rmssym. at 26.3 kVfor 0.17s after10 switchingoperations

    10,000 A rmssym. at 36.6for 0.17safte10 switchingoperations

    Short Time 10,000 A rmssym. for 0.17 s

    3,500 A rms sym.for 3.0s

    10,000 A rmssym. for 0.17 s

    3,500 A rms sym.for 3.0s

    10,000 A rmssym. for 0.17

    3,500 A rms syfor 3.0s

    600 A Deadbreak Connector Ratings in Accordance with IEEE Std. 386 sta

    Notes:* System design and protection must recognize the ratings of 200 A interface.** Optional 900 A rating is available. Refer to 600/900 A Deadbreak Connector section for mor

    detail.

    Cooper Power Systems 5

    rt e ests an er ormanceCertified Tests and Performance

  • 8/10/2019 Catalogo Power System

    6/56

    Part Number Selection Process for CableSensitive Products

    The Cooper Power Systems 200 A and 600 A connectorproducts are designed for applications on XLPE, EPR or otherolid dielectric insulated underground electrical cables. Inrder to maintain a reliable termination, the cable accessories

    must be sized correctly with the cable conductor size andable insulation diameter.

    The cable conductor size is used to determine the compression

    onnector used. Proper sizing is important to ensure reliableurrent transfer from the underground cable conductor tohe elbow connector. Conductor diameters are dependentn the conductor size in AWG or kcmil, and conductor type

    stranded, compressed, compact or solid).

    The cable insulation diameter (the diameter over the insulation)s critical because it is important to maintain a tightly sealedt between the cable insulation and the elbow housing athe cable entrance. As the insulation thickness changes,o must the range of the cable accessory. Cable insulationiameter can be determined from the cable manufacturer'specification, or by referring to pages 8 (for cable made to the

    AEIC Standard including the 0.030 inch tolerance) or 9 (forable made to the ICEA Standard) for minimum and maximum

    iameters.

    EXAMPLE:PROPER ELBOW PART NUMBER SELECTION

    Select a Cooper Power Systems 15 kV 200 A LoadbreakElbow with optional integral jacket seal and test point for anAEIC standard tape-shielded 15 kV cable with 133% insu-lation and 1/0 compact stranded conductor with an outerjacket diameter of 1.07".

    Step 1 Base Part Number Selection

    Select base part number of LEJ215from page 11 for 15 kVvoltage class. Note that on page 11 reference is also made totables CR1 and CC1.

    Step 2 Determine Insulation Outside Diameter Range

    Since cable is made to AEIC Standards, refer to page 8.133% 15 kV cable corresponds to 220 mil insulation wallthickness. The AEIC table gives a range of 0.805" to 0.865"for 1/0 compact 220 mil cable.

    Step 3 Elbow Cable Range Selection

    Refer to CR1 Table on page 13 and select a cable rangecode of "AB" with a range of 0.610" to 0.970" to cover0.805" to 0.865".

    Step 4 Elbow Connector Selection

    Refer to CC1 Table on page 13 and select a conductorcode of "05" which applies to the specified 1/0 compactconductor.

    Step 5 Optional Test Point Selection

    In accordance with note 1 on page 11, for an elbow with testpoint, add a "T" after the cable range and conductor code.

    Step 6 Optional Ground Strap

    Tape-shielded cable requires a ground strap and bleeder wireto terminate. Add "GS" after test point option.

    Step 7 Ordering

    Therefore, order Cooper Power Systems part number

    LEJ215AB05TGS

    CABLE RANGE

    CODE (CR1)LEJ215

    ABCONDUCTORCODE (CC1)LEJ215

    AB 05LEJ215 T

    AB 05LE215 TGS

    Conductor Sizing

    6 Specifiers Guide: Components Master Catalog

    Conductor Sizing

  • 8/10/2019 Catalogo Power System

    7/56

    ConductorSize

    AWG or kcmil

    No. of Strandsand their Nom.Strand Dia. (in.)

    Cross-sectional AreaStranded

    Conductors(inches)

    CompressedConductors

    (inches)

    CompactConductors

    (inches)

    SolidConducto

    (inches)SquareInches

    mm2

    Conversion

    14 7 x 0.0242 0.0032 2.08 0.073 - - 0.064

    12 7 x 0.0305 0.0051 3.31 0.092 - - 0.081

    10 7 x 0.0385 0.0082 5.26 0.116 - - 0.102

    8 7 x 0.0486 0.0130 8.37 0.146 - - 0.1296 7 x 0.0612 0.0206 13.30 0.184 - - 0.162

    4 7 x 0.0772 0.0328 21.15 0.232 - - 0.204

    2 7 x 0.0974 0.0521 33.62 0.292 0.283 0.268 0.258

    1 19 x 0.0664 0.0657 42.41 0.332 0.322 0.299 0.289

    1/0 19 x 0.0745 0.0829 53.49 0.373 0.362 0.336 0.325

    2/0 19 x 0.0837 0.1045 67.43 0.418 0.405 0.376 -

    3/0 19 x 0.0940 0.1318 85.01 0.470 0.456 0.423 -

    4/0 19 x 0.1055 0.1662 107.2 0.528 0.512 0.475 -

    250 37 x 0.0822 0.1964 127 0.575 0.558 0.520 -

    350 37 x 0.0973 0.2749 177 0.681 0.661 0.616 -

    500 37 x 0.1162 0.3927 253 0.813 0.789 0.736 -

    600 61 x 0.0992 0.4712 304 0.893 0.866 0.813 -

    700 61 x 0.1071 0.5498 355 0.964 0.935 0.877 -750 61 x 0.1109 0.5891 380 0.998 0.968 0.908 -

    800 61 x 0.1145 0.6283 405 1.031 1.000 0.938 -

    900 61 x 0.1215 0.7069 456 1.094 1.061 0.999 -

    1000 61 x 0.1280 0.7854 507 1.152 1.117 1.060 -

    Cable Conductor Reference

    OUTER JACKET

    METAL NEUTRALOR SHIELD

    INSULATIONSHIELD

    DIAMETER OVERINSULATION (CR)

    CONDUCTOR

    CONDUCTORSHIELD

    INSULATION

    Illustration showing typical construction of medium voltage underground cable.

    Cable insulation

    CABLEINSULATIONDIAMETER

    INSULATIONWALL

    THICKNESS

    Types of Stranded Conductor

    CONCENTRICSTRANDED

    COMPRESSEDSTRANDED

    COMPACTSTRANDED

    CR

    7Cooper Power Systems

  • 8/10/2019 Catalogo Power System

    8/56

    175 mil is 100% insulated cable at 15 kV.

    220 mil is 133% insulated cable at 15 kV.260 mil is 100% insulated cable at 25 kV.

    345 mil is 133% insulated cable at 25 kV.

    345 mil is 100% insulated cable at 35 kV.

    InsulationAWG or

    kcmil

    WallThickness*

    (Inches)VoltageClass kV

    ConcentricStranded

    CompressedStranded

    CompactStranded Solid

    Min.Dia.

    (inches)

    Max.Dia.

    (inches)

    Min.Dia.

    (inches)

    Max.Dia.

    (inches)

    Min.Dia.

    (inches)

    Max.Dia.

    (inches)

    Min.Dia.

    (inches)

    Max.Dia.

    (inches)

    #2

    .175

    .220

    .260

    .345

    15152535

    0.6700.760

    0.7300.820

    0.6650.775

    0.7250.815

    0.6500.740

    0.7100.800

    0.6400.730

    0.7000.790

    #1

    .175

    .220

    .260.345

    1515

    2535

    0.7100.800

    0.880

    0.7700.860

    0.940

    0.7000.790

    0.870

    0.7600.850

    0.930

    0.6800.770

    0.850

    0.7400.830

    0.910

    0.6700.760

    0.840

    0.7300.820

    0.900

    1/0

    .175

    .220

    .260

    .345

    15152535

    0.7550.8450.9251.095

    0.8150.9050.9851.155

    0.7400.8300.9101.080

    0.8000.8900.9701.140

    0.7150.8050.8851.055

    0.7750.8650.9451.115

    0.7050.7950.8751.045

    0.7650.8550.9351.105

    2/0

    .175

    .220

    .260

    .345

    15152535

    0.8000.8900.9701.140

    0.8600.9501.0301.200

    0.7850.8750.9551.125

    0.8450.9351.0151.185

    0.7550.8450.9251.095

    0.8150.9050.9851.155

    0.8050.8350.9151.085

    0.9050.8950.9751.145

    3/0

    .175

    .220

    .260

    .345

    15152535

    0.8500.9401.0201.190

    0.9101.0001.0801.250

    0.8350.9251.0051.175

    0.8950.9851.0651.235

    0.8050.8950.9751.145

    0.8650.9551.0351.205

    0.8500.8800.9601.130

    0.9400.9401.0201.190

    4/0

    .175

    .220

    .260

    .345

    15152535

    0.9101.0001.0801.250

    0.9701.0601.1401.310

    0.8900.9801.0601.230

    0.9501.0401.1201.290

    0.8550.9451.0251.195

    0.9151.0051.0851.255

    0.9000.9301.0101.180

    0.9900.9901.0701.240

    250

    .175

    .220.260

    .345

    15

    152535

    0.965

    1.0551.1451.320

    1.025

    1.1151.2051.380

    0.950

    1.0401.1301.305

    1.010

    1.1001.1901.365

    0.910

    1.0001.0951.265

    0.970

    1.0601.1501.325

    350

    .175

    .220

    .260

    .345

    15152535

    1.0701.1601.2501.425

    1.1301.2201.3101.485

    1.0501.1401.2301.405

    1.1101.2001.2901.465

    1.0051.0951.1851.360

    1.0651.1551.2451.420

    500

    .175

    .220

    .260

    .345

    15152535

    1.2051.2951.3851.560

    1.2651.3551.4451.620

    1.1801.2701.3601.535

    1.2401.3301.4201.595

    1.1251.2151.3051.480

    1.1851.2751.3651.540

    600

    .175

    .220

    .260

    .345

    15152535

    1.2951.3851.4751.650

    1.3551.4451.5351.710

    1.2651.3551.4451.625

    1.3251.4151.5051.680

    1.2151.3051.3951.570

    1.2751.3651.4551.630

    700

    .175

    .220

    .260

    .345

    15152535

    1.3651.4551.5451.720

    1.4251.5151.6051.780

    1.3351.4251.5151.690

    1.3951.4851.5751.750

    1.2751.3651.4551.630

    1.3351.4251.5151.690

    750

    .175

    .220

    .260

    .345

    15152535

    1.4001.4901.5801.755

    1.4601.5501.6401.815

    1.3701.4601.5501.725

    1.4301.5201.6101.785

    1.3101.4001.4901.665

    1.3701.4601.5501.725

    800

    .175

    .220

    .260

    .345

    15152535

    1.4301.5201.6101.785

    1.4901.5801.6701.845

    1.4001.4901.5801.755

    1.4601.5501.6401.815

    1.3401.4301.5201.695

    1.4001.4901.5801.755

    900

    .175

    .220

    .260

    .345

    15152535

    1.4951.5851.6751.850

    1.5551.6451.7351.910

    1.4601.5501.6401.815

    1.5201.6101.7001.875

    1.4001.4901.5801.755

    1.4601.5501.6401.815

    1000

    .175

    .220

    .260

    .345

    15152535

    1.5501.6401.7301.850

    1.6101.7001.7901.955

    1.5151.6051.6951.815

    1.5751.6651.7551.920

    1.4601.5501.6401.760

    1.5201.6101.7001.865

    Cable Insulation Diameters for Standard AEIC Cables with 175, 220, 260, and 345 mil Insulation Wall Thickness

    See table below for standard insulation thickness.

    AEIC Insulation Diameter Chart

    8 Specifiers Guide: Components Master Catalog8

    AEIC Insulation Diameter Chart

  • 8/10/2019 Catalogo Power System

    9/56

    ICEA Insulation Diameter Chart

    AWGor

    kcmil

    InsulationWall

    Thickness*(Inches)

    VoltageClass

    kV

    ConcentricStranded

    CompressedStranded

    CompactStranded Solid

    Min.Dia.

    (inches)

    Max.Dia.

    (inches)

    Min.Dia.

    (inches)

    Max.Dia.

    (inches)

    Min.Dia.

    (inches)

    Max.Dia.

    (inches)

    Min.Dia.

    (inches)

    MaxDia.

    (inche

    #2

    .175

    .220

    .260

    .345

    15152535

    0.6450.735

    0.7300.825

    0.6350.725

    0.7200.815

    0.6200.710

    0.7050.800

    0.6100.700

    0.690.79

    #1

    .175

    .220

    .260.345

    1515

    2535

    0.6850.775

    0.845

    0.7700.865

    0.935

    0.6750.765

    0.835

    0.7600.855

    0.925

    0.6550.745

    0.815

    0.7350.830

    0.905

    0.6450.735

    0.805

    0.720.82

    0.89

    1/0

    .175

    .220

    .260

    .345

    15152535

    0.7250.8150.8851.055

    0.8100.9050.9801.155

    0.7150.8050.8751.045

    0.8000.8950.9651.145

    0.6900.7800.8501.020

    0.7750.8650.9401.120

    0.6800.7700.8351.010

    0.760.850.921.11

    2/0

    .175

    .220

    .260

    .345

    15152535

    0.7750.8650.9351.105

    0.8550.9501.0251.200

    0.7600.8500.9201.090

    0.8450.9351.0101.190

    0.7300.8200.8901.060

    0.8150.9050.9801.160

    0.7150.8050.8751.045

    0.800.890.961.14

    3/0

    .175

    .220

    .260

    .345

    15152535

    0.8250.9150.9851.155

    0.9051.0001.0751.255

    0.8100.9000.9701.140

    0.8950.9851.0601.240

    0.7750.8650.9351.105

    0.8600.9551.0301.205

    0.7650.8550.9251.095

    0.840.941.011.19

    4/0

    .175

    .220

    .260

    .345

    15152535

    0.8800.9701.0401.210

    0.9651.0601.1351.310

    0.8650.9551.0251.195

    0.9501.0451.1151.295

    0.8300.9200.9901.160

    0.9101.0051.0801.260

    0.8150.9050.9751.145

    0.890.991.061.24

    250

    .175

    .220.260

    .345

    15

    152535

    0.935

    1.0251.0951.265

    1.020

    1.1151.1901.370

    0.920

    1.0101.0801.250

    1.005

    1.1001.1751.350

    0.880

    0.9701.0401.210

    0.965

    1.0601.1351.315

    350

    .175

    .220

    .260

    .345

    15152535

    1.0451.1351.2051.375

    1.1301.2201.2951.475

    1.0251.1151.1851.355

    1.1101.2001.2751.455

    0.9801.0701.1401.310

    1.0651.1551.2301.410

    500

    .175

    .220

    .260

    .345

    15152535

    1.1751.2651.3351.505

    1.2601.3551.4301.605

    1.1501.2401.3101.480

    1.2351.3301.4051.580

    1.1001.1901.2601.430

    1.1851.2751.3501.530

    600

    .175

    .220

    .260

    .345

    15152535

    1.2651.3551.4251.595

    1.3501.4451.5201.695

    1.2351.3251.3951.565

    1.3251.4151.4901.670

    1.1851.2751.3451.515

    1.2701.3651.4401.615

    700

    .175

    .220

    .260

    .345

    15152535

    1.3351.4251.4951.665

    1.4201.5151.5901.765

    1.3051.3951.4651.635

    1.3901.4851.5601.740

    1.2451.3351.4051.575

    1.3351.4301.5001.680

    750

    .175

    .220

    .260

    .345

    15152535

    1.3701.4601.5301.700

    1.4551.5501.6251.800

    1.3401.4301.5001.670

    1.4251.5201.5951.770

    1.2801.3701.4401.610

    1.3651.4601.5351.710

    800

    .175

    .220

    .260

    .345

    15152535

    1.4001.4901.5601.730

    1.4901.5801.6551.835

    1.3701.4601.5301.700

    1.4551.5501.6251.805

    1.3101.4001.4701.640

    1.3951.4901.5651.740

    900

    .175

    .220

    .260

    .345

    15152535

    1.4651.5551.6251.795

    1.5501.6451.7201.895

    1.4301.5201.5901.760

    1.5201.6101.6851.865

    1.3701.4601.5301.700

    1.4551.5501.6251.800

    1000

    .175

    .220

    .260

    .345

    15152535

    1.5201.6101.6801.850

    1.6101.7051.7751.955

    1.4851.5751.6451.815

    1.5751.6701.7401.920

    1.4301.5201.5901.760

    1.5151.6101.6851.865

    Cable Insulation Diameters for Standard ICEA Cables with 175, 220, 260, and 345 mil Insulation Wall Thickness

    175 mil is 100% insulated cable at 15 kV.

    220 mil is 133% insulated cable at 15 kV.260 mil is 100% insulated cable at 25 kV.

    345 mil is 133% insulated cable at 25 kV.

    345 mil is 100% insulated cable at 35 kV.

    * See table below for standard insulation thickness.

    Cooper Power Systems 9

    ICEA Insulation Diameter Chart

    9

    ICEA Insulation Diameter Chart

  • 8/10/2019 Catalogo Power System

    10/56

    EZII Splice

    LoadbreakElbow Connectorwith Test Point

    ShieldAdapter

    Bushing Well Insert w/Latch Indicator Ring

    Transformeror Switching

    Apparatus

    RotatableFeedthru Insert

    Bushing Well Plug

    One-Piece Bushing(35 kV only)

    Standoff

    Bushing

    Portable Feedthru

    ParkingStand Arrester

    Grounding Elbow

    LoadbreakJunction

    LoadbreakProtective Cap

    LoadbreakElbowConnector

    BushingWell

    M.O.V.E.

    ElbowArrester

    JacketSeal

    TPR FCI

    ER FCI

    FCI

    SectionalizingCabinets

    CR & LVR

    FCI

    LoadbreakElbow Connector

    LoadbreakJunction

    200 A Loadbreak Connectors

    Our 200 A 15, 25, and 35 kV Loadbreak ElbowConnectors and Accessories are submersible, fully-hielded and insulated plug-in terminations, ideal foronnecting underground cable to transformers,witchgear, sectionalizing cabinets and junctions.

    These connectors are molded using high-quality,peroxide-cured EPDM insulation for reliable fieldperformance.

    5 kV and 25 kV loadbreak elbows are availablewith an integral jacket seal for use with concentric

    eutral and other types of shielded cables.

    All 200 A loadbreak connectors meet the electrical,mechanical, and dimensional requirements of IEEEStd 386standard and are designed to be fullynterchangeable with other major manufacturersurrently complying with IEEE Std 386standard.

    25 kV POSI-BREAK Elbow and CapOur POSI-BREAK Elbow and Cap is an engineeredolution that increases strike distance and improveseliability. The added features solve problems, such as:

    n Partial Vacuum Flashovers Under certain conditionsduring 25 kV switching, a partial vacuum can decreasethe dielectric strength of the air inside the elbow/bushing

    or cap/bushing. This increases the possibility of aflashover from the elbow or caps probe along thebushing interface to the grounded collar on the matingbushing product. The POSI-BREAK design eliminatesthe possibility of partial vacuum flashovers duringswitching because of the increased strike distance.

    n Contamination The field-proven interface sealprevents the ingress of moisture or contaminants.However, contamination introduced during installationor switching operations can reduce the strike distancealong the interface. The increased insulation of thePOSI-BREAK design counteracts the effect ofcontamination, increasing system reliability.

    25 kV POSI-BREAK Elbow and CapSpecification Information

    To capitalize on the benefits of thePOSI-BREAK Elbow and Cap, includethe following information for boththe 25 kV 200 A Loadbreak Elbowand Insulated Protective Cap in yourspecification:

    n Both elbow and cap must fullycomply with IEEE Std 386standard.

    n Strike distance from energizedcomponent to ground shall beat least 5.6" at 1/2" interfaceseparation.

    n

    Both elbow and cap shall have aninsulated probe and conductiveFaraday Cage for relief of electricalstress and prevention of partialdischarge.

    nSemi-conductive insert shall becompletely surrounded with EPDMinsulating rubber.

    35 kV Elbow and Accessories Specification Information

    To capitalize on the benefits of our 35 kV Large Interface Elbow include thefollowing information in your specification:

    n The 200 A Elbows and Accessories shall be 21.1 kV/36.6 kV three-phaserated, meeting the requirements of IEEE Std 386standard interfaceNo. 1A (large 35 kV class interface).

    35 kV Large Interface Elbow Bushing System*Our 35 kV 200 A Large Interface Elbow Bushing System is areliable, field proven design. This system has over 25 years of field

    experience while being used on large 35 kV distribution systems. Featuresof the Large Interface System include:

    n Increased strike distance to provide greater reliability and overallperformance.

    n Reliableloadbreak switching and fault closure capability.n Full line of large interface accessory products.

    * Refer to bushing section on page 34 for more information on the bushing.

    JunctionBar

    JunctionBar

    Cable Transition Module

    TPR FCI

    BushingOpening

    ParkingStandBracket

    SD Cable LoadbreakElbow Connector

    1010

    200 A Loadbreak Connectors

  • 8/10/2019 Catalogo Power System

    11/56

    200 ALoadbreak &DeadbreakConnectors1. For an elbow with test point,

    a T after the conductor cod(CC1).

    2. For an elbow kit with a hold dbail assemblyincluded, inserafter the test point option codkV only.

    3. For optional braided ground sbleeder wire for termination tawire shielded cable, insert "GStest point and/or bail option c

    4. To include the SA Series ColdShrinkable Metallic Shield AdKitor CS Series Cold Shrink Sealing Kit, add the appropriasuffix "SA1", "SA2", "SA3", "Sor "CS1", "CS2", or "CS3"to end of the loadbreak elbow canumber. Refer to Tables CJ1 aCJ2 on Page 13.

    5. For individually packagedprin a corrugated cardboard boinsert an X as the last charain the part number.

    6. To order the long version(exed) of the bushing insert, puL as the seventh character ipart number.

    7. Specify the number of interfaby inserting a 2, 3, or 4directly after the base part num

    8. To add a stainless steel bracinsert a B as the last characthe part number, or to addU-straps, insert a U as the character in the part number.

    9. To substitute a stainless steebracket,insert a S as the lacharacter in the part number.

    10. Each CS Series Cold ShrinkSealing Kitincludes:(1) Cold Shrinkable Sleeve(2) Mastic Sealing Strips(1) Installation InstructionsFor use on Concentric NeutraCable.

    11. For use with tape shield, drainlinear corrugated and Unishiecable.

    12. Each SA Series Kitincludes:(1) Cold Shrinkable Sleeve(1) Tinned Copper Ground Str

    with attached elbow drain (1) Constant Force Spring(1) Semi-Conductive Tape(3) Mastic Sealing Strips(1) Installation Instructions

    13. Probe kit includes probe,installation tool, silicone lubricand installation instructions.

    Catalog Section Description kV Class Base Part Number Notes

    500-10

    Loadbreak Elbow 15 kV LE215CR1 CC1(see CR1 & CC1 Tables Pg. 13)

    1, 2, 4, 5

    500-10-7

    Loadbreak Elbow withIntegral Jacket Seal

    15 kV LEJ215CR1 CC1(see CR1 & CC1 Tables Pg. 13)

    1, 2, 3, 5

    500-28

    Loadbreak Elbow 25 kV LE225CR1 CC1(see CR1 & CC1 Tables Pg. 13)

    1, 4, 5

    500-28-7

    Loadbreak Elbow withIntegral Jacket Seal

    25 kV LEJ225CR1 CC1(see CR1 & CC1 Tables Pg. 13)

    1, 3, 5

    500-29

    POSI-BREAKLoadbreak Elbow

    25 kV PLE225CR1 CC1(see CR1 & CC1 Tables Pg. 13)

    1, 4, 5

    500-29-7

    POSI-BREAKLoadbreak Elbow with

    Integral Jacket Seal

    25 kV PLEJ225CR1 CC1(see CR1 & CC1 Tables Pg. 13)

    1, 3, 5

    500-41

    Loadbreak Elbow 35 kV LE235CR2 CC1(see CR2 & CC1 Tables Pg. 13)

    1, 4, 5

    500-12

    Loadbreak BushingInsert

    15 kV LBI215 5

    500-26

    Loadbreak BushingInsert

    25 kV LBI225 5, 6

    500-13500-30

    LoadbreakFeedthru Insert

    15 kV LFI215

    25 kV LFI225

    500-14

    Loadbreak Portable

    Feedthru

    15 kV

    horizontal LPF215Hvertical LPF215V

    universal LPF215U

    500-31

    Loadbreak PortableFeedthru

    25 kV

    horizontal LPF225H

    vertical LPF225V

    universal LPF225U

    500-49

    Loadbreak PortableFeedthru

    35 kV

    horizontal LPF235H

    vertical LPF235V

    500-15500-32500-51

    LoadbreakJunction

    15 kV LJ215C 7, 8

    25 kV LJ225C 7, 8

    35 kV LJ235C 7, 8

    500-20500-38

    Insulated BushingWell Plug

    15/25 kV IBWP225

    500-21

    LoadbreakProtective Cap

    15 kV LPC215 5

    500-39

    LoadbreakProtective Cap

    25 kV LPC225 5

    17.

    78 -2 3 .

    11 M M

    LE215B

    10 0 -.91 0

    I N

    (continued next page)

    1111

  • 8/10/2019 Catalogo Power System

    12/56

    Catalog Section Description kV Class Base Part Number Notes

    500-37

    POSI-BREAKLoadbreak

    Protective Cap

    25 kV PLPC225 5

    500-65

    LoadbreakProtective Cap

    35 kV LPC235 5

    500-22

    InsulatedStandoff Bushing

    15 kV ISB215 9

    500-40

    InsulatedStandoff Bushing

    25 kV ISB225 9

    500-66

    InsulatedStandoff Bushing

    35 kV ISB235 9

    SA Series ColdShrinkable MetallicShield Adapter Kit

    15/25/35 kV SACJ2(see CJ2 Table Pg. 13)

    4, 11, 12

    CS Series Cold ShrinkCable Seal Kit

    15/25/35 kV CS CJ1(see CJ1 Table Pg. 13)

    4, 10

    500-10500-28500-29500-41

    Coppertop Connector200 A, 2.88" Long

    Bi-Metal

    15/25/35 kV CC2C CC1 T(see CC1 Table Pg. 13)

    500-10500-28500-29500-41

    200 A LoadbreakProbe Kit

    15 kV PK215 13

    25 kV PK225PKPB225 (POSI-BREAK)

    1313

    35 kV PK235 13

    500-10500-28500-29500-41

    Silicone LubricantCooper 117

    (for Elbows and Splices)

    15/25/35 kV 2603393A03(0.175 oz., 5 g packet)

    2605670A02M(5.25 oz., 150 g tube)

    00 Aoadbreak &eadbreakonnectorsFor an elbow with test point, adda T after the conductor codeCC1).

    For an elbow kit with a hold downbail assemblyincluded, inserta B after the test point optioncode. 15 kV only.

    For optional braided ground strap/bleeder wire for termination tapeand wire shielded cable, insert"GS" after test point and/or bailoption code.

    To include the SA Series ColdShrinkable Metallic ShieldAdaptersKitor CS Series ColdShrink Cable Sealing Kit, add theappropriate suffix "SA1", "SA2",SA3", "SA4"or "CS1", "CS2", orCS3"to the end of the loadbreak

    elbow catalog number. Refer to

    Tables CJ1 and CJ2 on Page 13.

    For individually packagedprod-uctn a corrugated cardboard box,nsert an X as the last charactern the part number.

    To order the long versionextended) of the bushing insert,put in an L as the seventhcharacter in the part number.

    Specify the number of interfacesby inserting a 2, 3, or 4directly after the base part number.

    To add a stainless steel bracket,nsert a B as the last character in

    the part number, or to addU-straps, insert a U as the lastcharacter in the part number.

    To substitute a stainless steelbracket,insert a S as the lastcharacter in the part number.

    Each CS Series Cold ShrinkCable Sealing Kitincludes:1) Cold Shrinkable Sleeve2) Mastic Sealing Strips1) Installation InstructionsFor use on Concentric NeutralCable.

    For use with tape shield, drain wire,inear corrugated and Unishieldcable.

    Each SA Series Kitincludes:1) Cold Shrinkable Sleeve1) Tinned Copper Ground Strap

    with attached elbow drain wire1) Constant Force Spring1) Semi-Conductive Tape3) Mastic Sealing Strips1) Installation Instructions

    Probe kit includes probe,nstallation tool, silicone lubricantand installation instructions.

    For 200 A loadbreak inserts only.

    5 kV cable for use in 15 kV and 25kV CC size elbow only.

    Catalog Section Description kV Class Base Part Number Notes

    500-12Installation andTorque Tool

    15/25 kV LBITOOL 14

    500-10500-25

    Cable Adapter, 5 kV0.495" - 0.585"0.575" - 0.685"

    15/25 kVCA225ACA225B

    1515

    500-15500-32500-51

    U-Strap Kit withHardware (1 strap)

    for Loadbreak Junction

    15 kV 2625439A16B

    25 kV 2625439A17B

    35 kV 2637570A01B

    500-15500-32500-51

    2-way Stainless SteelBracket Assembly forLoadbreak Junction

    15 kV 2637172B01BS

    25 kV 2637160B01BS

    35 kV 2604688B01B

    500-15500-32500-51

    3-way Stainless SteelBracket Assembly forLoadbreak Junction

    15 kV 2637172B02BS

    25 kV 2637160B02BS

    35 kV 2604688B02B

    500-15500-32500-51

    4-way Stainless SteelBracket Assembly forLoadbreak Junction

    15 kV 2637172B03BS

    25 kV 2637160B03BS

    35 kV 2604688B03B

    (continued from previous page)

    12 Specifiers Guide: Components Master Catalog

    200 A Loadbreak & Deadbreak Connectors200 A Loadbreak & Deadbreak Connectors

  • 8/10/2019 Catalogo Power System

    13/561313

    Use forBase Number

    LE215

    LEJ215

    LE225

    LEJ225

    PLE225

    PLEJ225

    Use forBase Number

    LE235

    Use forBase Number

    LE215

    LEJ215

    LE225

    LEJ225

    PLE225

    PLEJ225

    LE235

    CC2C

    TABLE CJ1Jacketed Concentric Neutral Cabl

    Minimum SealDiameterInches

    MaximumInstalledDiameter(Inches) CO

    0.950 1.94

    1.28 2.67

    1.60 3.50

    Use forBase Number

    CS

    Use forBase Number

    SATABLE CR2Cable Diameter (Insulation) Range

    Cable Diameter Range CABLERANGE CODE

    Inches Millimeters

    0.825-1.000 21.00-25.40 B

    0.995-1.180 25.20-30.00 D

    1.180-1.340 30.00-34.00 F

    TABLE CC1Conductor Size and Type

    *Compressed stranding only.

    TABLE CJ2Cable Jacket (Outside Diameter) R

    Cable Jacket OD

    (Inches)

    JACK

    COD

    0.590-1.050 1

    0.830-1.640 2

    1.270-2.170 3

    1.600-2.600 4

    TABLE CR1Cable Diameter (Insulation) Range

    *Uses 5 kV cable adapter. (For use with "CC" range elbow only.)

    Cable Diameter Range CABLE RANGECODEInches Millimeters

    0.495-0.585 12.6-14.9 CCA*

    0.575-0.685 14.6-17.4 CCB*

    0.610-0.970 15.5-24.6 AB

    0.750-1.080 19.1-27.4 CC

    0.920-1.310 23.3-33.2 DD

    Concentric orCompressed Compact or Solid

    CONDUCTOR CODEAWG mm2 AWG mm2

    No Connector 00

    #6 16 #4 - 01

    #4 - #3 25 02

    #3 25 #2 35 03

    #2 35 1 - 04

    #1 - 1/0 50 05

    1/0 50 2/0 70 06

    2/0 50 3/0 - 07

    3/0 - 4/0 95 08

    4/0 95 250 20 09250* 120 300 - 10

    13Cooper Power Systems

  • 8/10/2019 Catalogo Power System

    14/56

    Catalog Section Description kV Class Base Part Number Notes

    550-10

    Deadbreak Elbow 15/25 kV DE225CR3 CC2T(see CR3 & CC1 Tables, page 15)

    1, 2

    550-12Deadbreak

    Straight15/25 kV DS225CR3 CC2T

    (see CR3 & CC1 Tables, page 15)1, 2

    I550-12

    DeadbreakJunction

    15/25 kV DJ250-4(4-way)

    3, 4

    15/25 kV DJ250-T1(3-way, Type 1)

    3, 4

    15/25 kV DJ250-T2(3-way, Type 2)

    3, 4

    15/25 kV DJ250-2 3, 4

    I550-13

    InsulatedDeadend Plug

    15/25 kV DPD250 3

    I550-13

    Insulated StandoffBushing

    15/25 kV DPS250 3

    I550-13

    GroundedStandoffBushing

    15/25 kV DPE250 3

    I550-13

    DeadbreakProtective

    Cap

    15/25 kV DRC250 2

    I550-15

    ApparatusBushing

    15/25 kV DB250DB250S

    (Short Shank)DB250L

    (Long Shank)

    I550-13

    CoppertopConnectors

    for DeadbreakElbows

    15/25 kV CC2C CC2T(see CC2 Table, page 15)

    I550-13

    Crimp Connectorsfor Deadbreak

    Straight

    15/25 kV CC2C CC2S(see CC2 Table, page 15)

    I550-13

    Probe and ProbeWrench for

    Deadbreak Elbow

    15/25 kV 2638370C01EX(Probe)

    2639205B01(Probe Wrench)

    550-10

    Bail Assemblyfor DE225

    15/25 kV 2638409C06B

    To add a premolded concentricneutral jacket sealto the elbowkit, add the code GC_ (third digits jacket code from the cableacket range outside diameterrange chart Table CJ1 on page 13)as the last characters in the partnumber.

    Bail assembly included in kit.

    Bail assembly is orderedseparately.

    See following for appropriateunction strap. For DJ250-2 andDJ250-T1, order 2639524B01. ForDJ250-T2, order 2638617C01. ForDJ250-4, consult factory.

    200 A LOADBREAK CONNECTORS

    14 Specifiers Guide: Components Master Catalog14

    200 A Loadbreak & Deadbreak Connectors

  • 8/10/2019 Catalogo Power System

    15/56

    Use forBase Number

    DE225

    DS225

    Use for

    Base Number

    DE225

    DS225

    CC2C

    TABLE CR3Cable Diameter (Insulation) Range

    Cable Diameter Range CABLERANGE CODEInches Millimeters

    0.531-0.685 13.5-17.4 BA

    0.640-0.820 16.3-20.8 DA

    0.770-0.950 19.6-24.1 FA

    0.910-1.130 23.1-28.7 HA

    1.100-1.320 27.9-33.5 JA

    TABLE CC2Conductor Size and Type

    Concentric or Compressed Compact or Solid CONDUCTORCODEAWG mm2 AWG mm2

    No Connector 00

    #6 16 #4 - 01

    #4 - #3 25 02

    #3 25 #2 35 03

    #2 35 #1 - 04

    #1 - 1/0 50 05

    1/0 50 2/0 70 06

    2/0 70 3/0 - 07

    3/0 - 4/0 95 08

    4/0 95 250 120 09

    250* 120 300 - 10

    *Compressed stranding only.

    Cooper Power Systems 1515

  • 8/10/2019 Catalogo Power System

    16/56

    200 A Stacking Dimensions

    Elbow Connector (25 kV POSI-BREAK shown)

    S4

    S3

    S6

    S5

    Insulated Standoff Bushing (25 kV shown)

    A

    S2

    oadbreak Protective Cap (25 kV POSI-BREAK shown)

    S3

    S4

    S3

    S5

    S8S7

    S6

    Loadbreak Portable Feedthru (15 kV shown)

    nsulated Bushing Well Plug

    S3

    A

    S2

    S1

    Bushing Insert with Latch Ring Indicator (25 kV shown)

    S1 S2

    Rotatable Feedthru Insert (25 kV shown)

    S2

    A

    A

    S2

    Dim. 15 kV 25 kV 35 kV

    S33.44"

    (87 mm)3.86"

    (98.04 mm)4.13"

    (105.0 mm)

    S44.16"

    (106 mm)4.54"

    (115.32 mm)5.01"

    (127.3 mm)

    S52.73"

    (69 mm)3.14"

    (79.76 mm)3.58"

    (91.0 mm)

    S61.23"

    (31 mm)1.64"

    (41.66 mm)1.77"

    (45.0 mm)

    Dim. 15 kV 25 kV Short 25 kV Long

    S1 0.76"(19.3 mm)

    0.76"(19.3 mm)

    0.76"(19.3 mm)

    S2 6.3"(106 mm)

    7.14"(181.4 mm)

    9.97"(253.2 mm)

    Dim. 15 kV 25 kV

    A 7.1"(179 mm)

    7.1"(179 mm)

    S2 9.50"(241 mm)

    11.0"(279 mm)

    Dim. 15 kV/25 kV

    S3 5.1"(130 mm)

    A 2.7"(69 mm)

    Dim. 15 kV 25 kV 35 kV

    S3 2.15"(54.5 mm)

    2.61"(66.3 mm)

    2.66"(67.5 mm)

    Dim. 15 kV 25 kV 35 kV

    A 6.3"(160 mm)

    6.3"(160 mm)

    7.1"(181 mm)

    S2 5.91"(150 mm)

    7.34"(186 mm)

    11.67"(296.4 mm)

    Dim.

    15 kV 25 kV 35 kV

    Horizontal Vertical Horizontal Vertical Horizontal Vertical

    B 5.6"(142.2 mm)

    5.6"(142.2 mm)

    7.2"(182.9 mm)

    D 8.9"

    (226 mm) 8.9"

    (226 mm) 11.6"

    (294 mm)

    E 6.0"(153 mm)

    6.7"(171 mm)

    8.8"(224 mm)

    S3 3.44"(87 mm)

    3.44"(87 mm)

    3.86"(98 mm)

    3.86(98 mm)

    4.13"(105 mm)

    4.13"(105 mm)

    S4 4.16"(106 mm)

    4.16"(106 mm)

    4.54"(115 mm)

    4.54"(115 mm)

    5.01"(127.3 mm)

    5.01"(127.3 mm)

    S5 2.73"(69 mm)

    2.73"(69 mm)

    3.14"(80 mm)

    3.14"(80 mm)

    3.58"(91 mm)

    3.58"(91 mm)

    S6 1.23"(31 mm)

    1.23"(31 mm)

    1.64"(42 mm)

    1.64"(42 mm)

    1.77"(45 mm)

    1.77"(45 mm)

    S7 0.75"(19 mm)

    0.75"(19 mm)

    0.75"(19 mm)

    0.75"(19 mm)

    0.75"(19 mm)

    0.75"(19 mm)

    S8 7.07"(180 mm)

    7.20"(183 mm)

    8.63"(219 mm)

    8.77"(223 mm)

    11.8"(300 mm)

    11.8"(300 mm)

    ED B

    16 Specifiers Guide: Components Master Catalog

    200 A Stacking Dimensions

  • 8/10/2019 Catalogo Power System

    17/56

    S10

    S9

    S7

    E

    MIN.

    MIN.

    MIN.

    M4

    B

    MAX.

    MAX.

    MAX.

    CONFIGURATION 3*

    CONFIGURATION 2*

    CONFIGURATION 1*

    S11

    A

    Underground Surge Arresters

    A

    2.2"(55 mm)

    S3

    Parking Stand Arresters

    A

    B

    2.2"(55 mm)S8

    Loadbreak Junctions (15 kV shown)

    ** Refer to CatalogSection 500-51 fordetailed drawing of 35 kV

    junction.

    VariGAP MOV Parking Stand Arrester

    Dim.Duty

    Cycle (kV) 15 kV 25 kV

    A9-15 11.9" (302 mm) 11.9" (302 mm)

    18-21 14.5" (368 mm) 14.5" (368 mm)

    B 9-15 8.0" (203 mm) 8.0" (203 mm)18-21 10.6" (269 mm) 10.6" (269 mm)

    S8 9-21 7.4" (188 mm) 7.4" (188 mm)

    MOV Parking Stand Arrester

    Dim.Duty

    Cycle (kV) 15 kV 25 kV

    A 3-21 11.9" (302 mm) 11.9" (302 mm)

    B 3-21 8.0" (203 mm) 8.0" (203 mm)

    S8 3-21 7.4" (188 mm) 7.4" (188 mm)

    Dim.Duty

    Cycle (kV) 15 kV/25 kV 35 kV

    A9-15 8.5" (216 mm)

    18-27 10.9" (276 mm) 13.3" (338 mm)

    S3 9-27 4.2" (107 mm) 4.7" (120 mm)

    VariGAP M.O.V.E. Arrester

    M.O.V.E. Arrester

    Dim.

    Duty

    Cycle (kV) 15 kV/25 kV 35 kV

    A 3-27 8.5" (216 mm) 13.3" (338 mm)

    S3 3-27 4.2" (107 mm) 4.7" (120 mm)

    Dim. 15 kV 25 kV 35 kV

    E 3.25" (83 mm) 4.0" (102 mm) 5.0" (127 mm)

    S7 0.75" (19 mm) 0.75" (19 mm) 1.02" (26 mm)

    S9 4.38" (111 mm) 4.38" (111 mm) 5.46" (139 mm)

    S10 6.77" (172 mm) 8.34" (212 mm) 11.8" (299 mm)S11 9.20" (234 mm) 10.77" (274 mm) 13.9" (163 mm)

    M4 See Table 15 kV See Table 25 kV See Table 35 kV

    Numberof

    Interfaces

    Mounting Dimensions in./mm

    A B C D

    2 23.1"(587mm)

    8.8":(223mm)

    ** **

    3 33.3"(846mm)

    13.8"(350mm)

    ** **

    4 38.5"(978mm)

    18.8"(477mm)

    ** **

    TABLE 35 kV

    Numberof

    Interfaces

    PhysicalDimensions

    in./mm

    M4 Mounting Dimensions in./mm

    Configuration 1 Configuration 2 Configuration 3

    A B Min. Max. Min. Max. Min. Max.

    212.5"(318mm)

    6.0"(152mm)

    10.8"(275mm)

    14.4"(366mm)

    7.2"(183mm)

    10.8"(275mm)

    3.6"(92

    mm)

    7.2"(183mm)

    319.6"(498mm)

    9.2"(230mm)

    14.7"(374mm)

    18.3"(465mm)

    11.1"(282mm)

    14.7"(374mm)

    7.4"(188mm)

    11.1"(282mm)

    422.9"(582mm)

    12.4"(315mm)

    17.9"(455mm)

    21.5"(547mm)

    14.3"(364mm)

    17.9"(455mm)

    10.7"(272mm)

    14.3"(364mm)

    TABLE 15 kV

    Configuration 1. Both feet turned out. Configuration 2. One foot turned out, one in. Configuration 3. Both feet turned in.

    TABLE 25 KV

    Numberof

    Interfaces

    PhysicalDimensions

    in./mm

    M4 Mounting Dimensions in./mm

    Configuration1

    Configuration2

    Configuration3

    A B Min. Max. Min. Max. Min. Max.

    214.2"(361mm)

    6.7"(170mm)

    11.9"(302mm)

    15.6"(396mm)

    8.0"(203mm)

    11.7"(297mm)

    4.2"(107mm)

    7.8"(198mm)

    323.0"(584mm)

    10.7"(272mm)

    16.8"(427mm)

    20.4"(518mm)

    12.9"(328mm)

    16.5"(419mm)

    9.0"(229mm)

    12.6"(320mm)

    4 27.0"(686mm)

    14.7"(373mm)

    20.8"(528mm)

    24.4"(620mm)

    16.9"(429mm)

    20.5"(521mm)

    13.0"(330mm)

    16.6"(422mm)

    Configuration 1. Both feet turned out. Configuration 2. One foot turned out, one in. Configuration 3. Both feet turned in.

    Cooper Power Systems 1717

  • 8/10/2019 Catalogo Power System

    18/56

    600 A/900 A Deadbreak Connectors

    Connecting Plug

    200 ALoadbreak Elbow

    BushingAdapter

    BOL-TConnector

    BOL-T Connector

    One-PieceBushing

    StandoffBushing

    ParkingStand

    Bracket

    Transformeror Switchgear

    Apparatus

    Grounding Elbow

    U-OP Connector**

    200 AProtective

    Cap

    PUSH-OPConnector*

    T-OP IIConnector/BT-TAPConnector

    T-OP II Connector

    BT-TAP Connector

    M.O.V.E. Arrester

    FCI

    ER FCI

    CR & LVR FCI

    TPR FCI

    FCI

    Deadbreak Junction

    DeadbreakJunction

    LoadbreakProtective Cap

    ShieldAdapter

    DeadbreakJunction

    U-OP **

    * PUSH-OP requires modified bushing and tank hardware.**U-OP requires frontplate stud provisions. Refer to Installation Instructions S600-14-1 for details.

    Our 600/900 A Deadbreak Connector Systems are designedo fill the demand for a deadfront underground installation 600/900 A main and lateral feeders. They provide aompletely shielded, deadfront, fully submersible cableonnection for high-voltage apparatus such as transformers,witchgear, large motors, etc., and can also be used to makeplices, junctions, taps and deadends for main underground,stribution feeders. They provide the same high degree ofperating flexibility and reliability as our 200 A products. Allomponents fit together easily and assembly variations are

    vailable.hese connector systems are designed for installation onarious types of cables. The entire system can be applied tooncentric neutral cable, and with our CS & SA Series Shielddapter Kits to almost any other type of cable.

    ll of our Deadbreak Connectors meet the electrical,mechanical and dimensional requirements of IEEE Std 386tandard and are designed to be fully interchangeable withhose currently available from other major manufacturers.

    00 A RATING

    900 A continuous rating can be achieved with BOL-T,T-TAP and T-OP II Systems when used with a coppertopompression connector and all copper mating componentscluding apparatus bushing or junction. (See note 1 on page

    9 for details when selecting a system.)

    OL-T Connector System

    Our BOL-T Deadbreak Connector System is designed forse on applications where the terminations would not beperated after installation, would not need a 200 A interface

    or grounding or arrester provisions, and would not requirerect conductor testing or the use of a hotstick. It is a boltedesign that is interchangeable with other manufacturersolted 600/900 A systems and requires no special tools forstallation.

    T-TAP Connector System

    Our BT-TAP Deadbreak Connector System includes a 200 Aoadbreak tap instead of the standard insulated plug. The

    ther components of BT-TAP are the same as BOL-T, makingan ideal option to retrofit existing BOL-T (or other bolted

    ystems that use unthreaded compression connectors)ystems with a 200 A loadbreak tap for testing, grounding, orvervoltage protection.

    -OP II Connector System

    Our T-OP II Deadbreak Connectorystem also has a 200 A loadbreak tap andas all the advantages of the BT-TAPystem. In addition, the T-OP II isngle-person hotstick operable, makingideal for terminations that may

    equire moving or sectionalizing tochieve a visible open or visible

    round. The T-OP II design offersdded reliability (900 A rated allopper alloy current path and copperop connector) and has severalssembly/operating advantages.

    USH-OP Connector System

    Our PUSH-OP Deadbreak Connectorystem is essentially a T-OP IIermination with a non-bolted designor use on any deadfront apparatuswhere the terminations may be

    perated frequently. The PUSH-OP00 A deadbreak probe and finger

    contact design eliminates cross-threading and normal threadwear during repeated sectionalizing operations. It is the onlyavailable system that allows operators to move the terminatorwhile it is fully grounded. The PUSH-OP System providesstainless steel bracketry and a mechanical lever for the fastestand easiest one-person hotstick operation possible. ThePUSH-OP System requires special apparatus bushings, whichmakes it suitable for new installations only.

    U-OP Connector System

    Our U-OP Deadbreak Connector System is used with T-OP IIand designed to provide a visible break and visible groundwithout having to move large 600 A cable. The U-OP Systemrequires special apparatus bracketry, which makes it suitablefor new installations only.

    Note: 600 A Separable Splice kits can be found in the splice section onpage 27.

    JunctionBars

    JunctionBars

    T-OP II

    Cable Transition Module

    BOL-T

    BOL-TSplice

    Type LCutout

    UltraSILArrester

    CR FCI

    SectionalizingCabinets

    BushingAdapter

    600 AProtective Cap

    200 A LOADBREAK & DEADBREAK CONNECTORS

    1818

    600/900 A Deadbreak Connectors

  • 8/10/2019 Catalogo Power System

    19/56

    1. Determine whether all aluminucomponents or all coppercomponents are required:

    BOL-T Kitwith 600 A Rating"A" in digit 9forAluminum.

    BT-TAP Kitwith 600 A RatinInsert "A" in digit 10forAlum

    BOL-T Kitwith 900 A Rating"C" in digit 9for Copper(inclucoppertop compression conn

    BT-TAP Kitwith 900 A RatinInsert "C" in digit 10for Copp(includes coppertop compres

    connector).2. To specify anALL copper conn

    add 50to the conductor code fTable CC3 (page 20). ExampleCC6C11T becomesCC6C61T

    3. To specify a stud: BOL-T Kit- insert a "1" in dig

    includestud, or a "2" in digitkit withoutstud.

    BT-TAP Kit- insert "S" in digito include standard lengthst"L" in digit 11to include extelength stud.

    4. To specify T-Body withtest po(optional):

    BOL-T Kit- insert a "T" in dig BT-TAP Kit(15 & 25 kV) - ins

    in digit 12.

    BT-TAP Kit(35 kV) - insert a digit 11.

    5. For T-OP II and PUSH-OP kits ospecify a T-body with test poiT after the conductor code.

    6. To specify a BOL-T, BT-TAP oIIkit with a loadbreak proteccap, insert a "C" after the testnon-test point option. Bushin

    Adapters- insert a "C" as thecharacter of the part number.25 kVkits include a POSI-BRprotective Cap.

    7. To specify stud in kit, add SAaluminum stud(only availablealuminum interface); add SCcopper stud; add ST for T-stud; or add SU for U-OP s

    the last characters in the part n8. To specify a grounded stand

    bushing, replace the I with athe first character in the part n

    9. For individually packagedproa corrugated cardboard box, inX as the last character in thenumber.

    10. It is required to specify the nuinterfaces by inserting a 2, 3directly after the base part num

    11. To add a stainless steel bracinsert a B; or to add U-strapa U as the last character in tnumber.

    12. For use with tape shield, drainlinear corrugated, and Unishie

    cable.13. To add a CS Series Sealing k

    SA Series Adapter kitto the 6connector kit, add a CS_ orat end of catalog number. Refe

    Table CJ3 or CJ4 on page 20.

    14. Each SA Series Kitincludes:(1) Cold Shrinkable Sleeve (1) TCopper Ground Strap with attelbow drain wire (1) Constant Spring (1) Semi-Conductive TaMastic Sealing Strips (1) InstallaInstructions.Each CS Series Sealing Kitinc(1) Cold shrinkable sleeve, (3) Msealing strips, and (1) InstallationInstructions.

    Catalog Section Description kV Class Base Part Number Notes

    600-10600-30600-50

    BOL-TConnector Kit

    15/25 kV BT625CR4 CC3(see CR4 & CC3 Tables pg. 20)

    1, 2, 3, 4, 13,14

    35 kV BT635CR5 CC3(see CR5 & CC3 Tables pg. 20)

    1, 2, 3, 4, 13,14

    600-15

    600-35600-55

    BT-TAPConnector Kit

    15 kV BTP615CR4 CC3(see CR4 & CC3 Tables pg. 20)

    1, 2, 3, 4, 6,13, 14

    25 kV BTP625CR4 CC3(see CR4 & CC3 Tables pg. 20)

    1, 2, 3, 4, 6,13, 14

    35 kV BTP635CR5 CC3(see CR5 & CC3 Tables pg. 20)

    1, 2, 4, 6, 13,14

    600-12600-32600-52

    T-OP IIConnector Kit

    15 kV TP615CR4 CC3(see CR4 & CC3 Tables pg. 20)

    2, 5, 6, 13, 14

    25 kV TP625CR4 CC3(see CR4 & CC3 Tables pg. 20)

    2, 5, 6, 13, 14

    35 kV TP635CR5 CC3(see CR5 & CC3 Tables pg. 20)

    2, 5, 6, 13, 14

    600-13600-33600-53

    PUSH-OPConnector Kit

    15 kV POP615CR4 CC3(see CR4 & CC3 Tables pg. 20)

    2, 5, 6, 13, 14

    25 kV POP625CR4 CC3(see CR4 & CC3 Tables pg. 20)

    2, 5, 6, 13, 14

    35 kV POP635CR5 CC3(see CR5 & CC3 Tables pg. 20)

    2, 5, 6, 13, 14

    600-34

    U-OP

    Connector Kit

    15/25 kV UOP625

    600-18600-38600-59

    Bushing Adapterwith LRTP

    (Stud-T Included)

    15 kV DBA615 6

    25 kV DBA625 6

    35 kV DBA635 6

    600-19600-39600-58

    PUSH-OP BushingAdapter

    15 kV PDBA615 6

    25 kV PDBA625 6

    35 kV PDBA635 6

    600-44600-64

    StandoffBushings

    15/25 kV ISB625A(Aluminum)ISB625C(Copper)

    7

    7, 8

    35 kV ISB635A(Aluminum)ISB635C(Copper)

    7, 8

    7

    600-25600-45600-65

    PUSH-OPStandoff Bushings

    15/25 kV PISB625PISB625HP(with hitch pin)

    35 kV PISB635PISB635HP(with hitch pin)

    600-43600-63

    StandardProtective Cap

    (with Permanent Stud)

    15/25 kV DPC625 9

    35 kV DPC635 9

    600-43600-63

    Protective Capfor T-OP II and

    U-OP

    15/25 kV DPC625UT 9

    35 kV DPC635UT 9

    600-42600-62

    DeadbreakJunctions

    15/25 kV DJ625A_(Aluminum)DJ625C_(Copper)

    10, 11

    10, 11

    35 kV DJ635A_(Aluminum)DJ635C_(Copper)

    10, 11

    10, 11

    500-95

    SA Series ColdShrinkable MetallicShield Adapter Kit

    15/25/35 kV SACJ3(see CJ3 Table pg. 20)

    12, 13, 14

    CS Series ColdShrinkable Metallic

    Cable Seal Kit

    15/25/35 kV CSCJ4(see CJ4 Table pg. 20)

    13, 14

    DEADBREAK

    PUSH HERE

    RTE

    Cooper Power Systems 1919

  • 8/10/2019 Catalogo Power System

    20/56

    600 A Deadbreak Connectors

    TABLE CR4Cable Diameter (Insulation) Range

    Cable Diameter Range

    Inches mmCABLE RANGE

    CODE

    0.640-0.760 16.3-19.3 A

    0.720-0.845 18.3-21.5 B

    0.785-0.970 19.9-24.6 C

    0.910-1.065 23.1-27.1 D0.980-1.140 24.9-29.0 E

    1.080-1.280 27.4-32.5 F

    1.220-1.420 31.0-36.1 G

    1.360-1.560 34.5-39.6 H

    1.480-1.700 37.6-43.2 J

    1.640-1.840 41.7-46.7 K

    1.780-1.965 45.2-49.9 L

    TABLE CJ3Cable Jacket (Outside Diameter) Range

    Cable JacketOD (Inches)

    JACKETCODE

    0.590-1.050 1

    0.830-1.640 2

    1.270-2.170 3

    1.600-2.600 4

    TABLE CJ4Jacketed Concentric Neutral Cable

    MinimumSeal

    Diameter(Inches)

    MaximumInstalled Diameter

    (Inches) CODE

    .950 1.94 1

    1.28 2.67 2

    1.60 3.50 3

    Use forBase Number

    BT625

    BTP615

    BTP625

    TP615

    TP625

    POP615

    POP625CA625

    Use forBase Number

    BT625

    BT635

    BTP615

    BTP625

    BTP635

    TP615

    TP625

    TP635

    POP615POP625

    POP635

    CC6A _ U

    CC6C _ T

    CC6C _ U

    Use forBase Number

    SA

    TABLE CR5Cable Diameter (Insulation) Range

    Cable Diameter Range

    Inches mmCABLE RANGE

    CODE

    0.875-0.985 22.2-25.0 D

    0.930-1.040 23.6-26.4 E

    0.980-1.115 24.9-28.3 F

    1.040-1.175 26.4-29.8 G

    1.095-1.240 27.8-31.5 H

    1.160-1.305 29.5-33.1 J

    1.220-1.375 31.0-34.9 K

    1.285-1.395 32.5-35.4 L

    1.355-1.520 34.4-38.6 M

    1.485-1.595 37.7-40.5 N

    1.530-1.640 38.9-41.7 P

    1.575-1.685 40.0-42.8 Q

    1.665-1.785 42.3-45.3 R

    1.755-1.875 44.6-47.9 S

    1.845-1.965 46.9-50.0 T

    1.960-2.210 49.8-56.1 U

    Concentric orCompressed

    Compact orSolid CONDUCTOR

    CODEAWG or kcmil mm2 AWG or kcmil mm2

    No Connector 00

    #2 35 1 _ 11

    #1 1/0 50 12

    1/0 50 2/0 70 13

    2/0 70 3/0 14

    3/0 4/0 95 15

    4/0 95 250 120 16

    250 120 300 17300 350 18

    350 400 185 19

    400 185 450 20

    450 500a 240 21

    500 240 600 300 22

    600 300 700 23

    650b 750c 24

    750d 900 25

    900 1000 500 26

    1000 500 27

    1250 630 28

    a. Also accepts 550 kcmil compact conductor.b. Also accepts 700 kcmil compressed conductor.

    c. Also accepts 800 kcmil compact conductor.d. Also accepts 700 kcmil concentric conductor.

    TABLE CC3Conductor Size and Type

    Use forBase Number

    BT635

    BTP635

    TP635

    POP635

    CA635

    Use forBase Number

    CS

    200 A LOADBREAK & DEADBREAK CONNECTORS

    2020 Specifiers Guide: Components Master Catalog20 Specifiers Guide: Components Master Catalog

    600/900 A Components & Replacement Parts

  • 8/10/2019 Catalogo Power System

    21/56

    600 A/900 A Components and Replacement Parts

    Catalog Section Description kV Class Base Part Number Notes

    600-46600-66

    T-Body 15/25 kV DT625 1, 2

    35 kV DT635 1, 2

    600-46600-66

    Cap forInsulating

    Plug

    15/25/35 kV DIPCAP

    600-46600-66

    InsulatingPlug

    w/o Stud(cap included)

    15/25 kV DIP625A(Aluminum)

    DIP625C(Copper)

    3, 7

    35 kV DIP635A(Aluminum)DIP635C(Copper)

    3, 7

    600-46600-66

    ConnectingPlug

    w/o Stud

    15/25 kV DCP625A(Aluminum)DCP625C

    (Copper)

    3, 7

    35 kV DCP635A(Aluminum)DCP635C

    (Copper)

    3, 7

    600-46

    600-66

    BOL-TStud

    15/25 kV STUD-A(Aluminum)STUD-C(Copper)

    35 kV STUD635-A(Aluminum)

    STUD635-C(Copper)

    600-46600-66

    T-OP II/BT-TAPStud

    15/25/35 kV STUD-T 4

    600-46600-66

    U-OPStud

    15/25/35 kV STUD-U 5

    600-46600-66

    11/16in. UnthreadedAluminum

    CompressionConnector

    15/25/35 kV CC6ACC3U(see CC3 Table pg. 20)

    600-46600-66

    15/16in.Threaded Coppertop

    CompressionConnector

    15/25/35 kV CC6C CC3T(see CC3 Table pg. 20)

    6

    600-46600-66

    11/16in.UnthreadedCoppertop

    CompressionConnector

    15/25/35 kV CC6C CC3 U(see CC3 Table pg. 20)

    6

    600-46600-66

    CableAdapter

    15/25 kV35 kV

    CA625 CR4(see CR4 Table pg. 20)

    CA635 CR5(see CR5 Table pg. 20)

    600-46600-66

    BT-TAP and T-OP IIInstallation andTorque Tool

    15/25 kV35 kV

    TQHD625TQHD635

    88

    600-46600-66

    T-OP II CombinationOperating, Test,and Torque Tool

    (For single personhotstick operation)

    15 kV OTTQ615 9

    25 kV OTTQ625 9

    35 kV OTTQ635 9

    600-46600-66

    T-WRENCH forBT-TAP/T-OP II

    15/25/35 kV TWRENCH 10

    600-18600-38600-59

    5/16" Hex Shaftwith 3/8" Socket

    Drive Tool

    15/25 kV HD625 11

    35 kV HD635 11

    600-18600-38600-59

    BushingExtender

    15/25 kV DBE625 2

    35 kV DBE635 2

    600-18600-38600-59

    LoadbreakReducing Tap Plug

    for T-OP II(Stud-T included)

    15 kV LRTP615

    25 kV LRTP625

    35 kV LRTP635

    600-18600-38600-59

    BOL-T LoadbreakReducing Tap Plug

    for BT-TAP

    15 kV BLRTP615 12, 13

    25 kV BLRTP625 12, 13

    35 kV BLRTP635

    1. To specify a test pointinsert in the sixth digit.

    2. To add stud to kit, add a SAan aluminum stud, or a SCcopper studas the last charain the part number.

    3. To add STUDto kit, add a Sthe base part number. Materiastud supplied will match with rial of the plug conductor orde

    4. Copper alloy stud for use withBT-TAP or T-OP II Connectors

    5. Copper stud for use with U-OConnector only.

    6. To specify an all copper conntor, add 50to the conductor from Table CC3 (page 20). ExCC6C11T becomes CC6C61T

    7. Stud comes loose in kit, add aas the last character for permfactory installation.

    8. TQHD6_ allows for installationeither BT-TAP or T-OP II Connto 600 A bushing.

    9. OTTQ6_ allows for installation

    single hotstick operation of eitBT-TAP or T-OP II Connector.

    10. TWRENCH allows for installatloadbreak reducing tap plug foBT-TAP or T-OP II Connector.

    11. HD6_ allows for installation ofconnecting plug in 600 A SepSplices.

    12. Specify "A" for 600 A rating ofor 900 A rating in digit 9.

    13. To add standard length stud tadd "S" to end of part numbe

    To add an extended length stkit add "L" to end of part num

    2121Cooper Power Systems 21

  • 8/10/2019 Catalogo Power System

    22/56

    BOL-T Connector SystemThe BOL-T Deadbreak Connector System is designed forse on applications that will not be operated, do not need

    grounding or arrester provisions, and do not require directconductor testing or the use of a hotstick. It is a bolted designhat is interchangeable with other manufacturers bolted 600 Aystems that require no special tools for installation.

    The capacitive test point on the insulating plug provides ameans of confirming an energized circuit without disturbinghe bolted connection. In addition to the capacitive test pointeature on the insulating plug, we offer a capacitive test pointon the T-Body. This allows the use of our Type TPR SeriesFaulted Circuit Indicators, and provides a means of confirm-ng that a circuit is energized when used with high impedanceoltage sensing devices designed for test points.

    Refer to Figure 1 for BOL-T Connector Kit Components.

    nstallation of BOL-T on a 600/900 A BushingThe BOL-T Connector is installed on any 600/900 A bushingsing a standard 1-inch socket. No special tools are required.

    BT-TAP Connector SystemThe BT-TAP Deadbreak Connector System is designed foruse on applications where a 200 A interface is required fortesting, grounding, or overvoltage protection. It is primarilyused in retrofit applications of existing 600 A or 900 A BOL-Tinstallations (or other bolted systems that use unthreadedcompression connectors).

    The BT-TAP Connector System uses the standard unthreadedcompression connector, which makes it ideal for retrofittingexisting BOL-T installations into a system with a 200 A tap.

    The BT-TAP provides the following features:

    n Visible ground and visible breakn 200 A Interface for:

    addition of our M.O.V.E. Arresters for overvoltageprotection

    addition of our Grounding Elbows access for direct conductor phasing and testing hipot testing of switch or cables

    Refer to Figure 2 for BT-TAP Connector Kit Components.

    Installation of BT-TAP on a 600 A BushingThe BT-TAP Connector is installed on an apparatus bushingusing a 600 A Torque Tool.BOL-T Specification Information

    To specify the BOL-T Connector System, include in yourspecification:

    n The system must fully comply with IEEE Std 386standard.

    n All cable adapters, insulating plugs, compression connectorsand other component parts must be interchangeable with othermanufacturers.

    n For 900 A rating, full copper current carrying path withcoppertop compression connector, copper stud and insulatingplug with copper insert.

    n BOL-T Connector System base part number BT625 for 15 kVand 25 kV systems and BT635 for 35 kV systems.

    igure 1.BOL-T Connector Kit (BT6_5) Components. For more details,ee catalog sections 600-10, 600-30 and 600-50.

    INSULATING PLUG WITH BOL-TSTUD (STUD-A)

    DIP625ASDIP635AS

    ALUMINUM COMPRESSIONCONNECTOR 11/16"UNTHREADED HOLE

    CC6A_ _ U

    CABLEADAPTER

    CA625CA635

    T-BODYDT625DT635

    BT-TAP Specification Information

    To specify a BT-TAP Connector System, include in yourspecification:

    n The system must fully comply with IEEE Std 386standard.

    n The connector system must provide operation with hot linetools, direct conductor phasing and testing.

    n It must provide a location to add overvoltage arresters andaccess for direct conductor phasing or hipot testing of switchor cables.

    n Must be easy to install with proper torque such that concern

    for cross threading is eliminated.

    n Loadbreak reducing tap plug must include latch indicator ring.

    n BT-TAP Connector System base part number BTP615 (A) (C) for15 kV, BTP625 (A) (C) for 25 kV and BTP635 for 35 kV.

    Figure 2.BT-TAP Connector Kit (BTP6_5_) Components. For more details,see catalog sections 600-15, 600-35 and 600-55.

    LOADBREAK REDUCINGTAP PLUG

    BLRTP615 (A) (C)BLRTP625(A) (C)

    BLRTP635

    ALUMINUM COMPRESSIONCONNECTOR 11/16"UNTHREADED HOLE

    CC6A_ _ U

    CABLE ADAPTERCA625CA635

    T-BODYDT625DT635

    STUD-ASTUD-C

    200 A LOADBREAK & DEADBREAK CONNECTORS

    2222 Specifiers Guide: Components Master Catalog

    600/900 A Connector Systems

  • 8/10/2019 Catalogo Power System

    23/56

    T-OP II Connector SystemThe T-OP II Deadbreak Connector System is designed for useon applications where a 200 A interface is required for testing,grounding, or overvoltage protection. It is single person hotstickoperable and is ideal for terminations that may require moving toachieve a visible open or visible ground. One person can movethe T-OP II Deadbreak Terminator from the apparatus bushingto a standoff bushing using a hotstick and Operating Test andTorque Tool (OTTQ6_5).

    The T-OP II Connector System uses a threaded coppertop (bi-metal) compression connector for a threaded connection. It alsohas an alignment segment and internal rotating nut feature in theloadbreak reducing tap plug which, along with the extended lengthstud, eliminates cross threading and ensures proper torque.

    The T-OP II system provides the following features:n Single person hotstick operablenMechanical assistn Copper alloy current path and copper-top connectorn 900 A continuous current ratingn Visible ground and visible breakn 200 A Interface for:

    addition of our M.O.V.E Arresters for overvoltageprotection

    addition of our Grounding Elbowsaccess for direct conductor phasing and testinghipot testing of switch or cables

    Refer to Figure 3 for T-OP II Connector Kit Components.

    Installation of T-OP II on a 600/900 A BushingThe T-OP II Connector is installed on an apparatus bushingusing a T-Wrench and a 600 A Torque Tool.

    U-OP Connector SystemThe U-OP Connector System is used to provide a visible and visible ground on 600 A distribution systems without havto move the heavy cable. The U-OP Connector is a deadbrsystem rated for operation on 15 or 25 kV class equipmenincluding transformers, switches, switchgear, and other apratus.

    Under normal operating conditions, the current path is throthe apparatus bushing, through the U-connector, through

    two-way 600 A deadbreak junction, and through a T-OP II 6A Connector (sold separately) to the underground cable. Wisolating underground cable, a grounded standoff bushing cbe put in the parking stand (with the system de-energized)U-connector can then be removed, rotated 90, and re-insover the apparatus bushing and grounded standoff bushingground the apparatus bushing.

    A grounding elbow can be installed on the 200 A interfaceof the T-OP II Connector to ground the cable. A 600 A U-OProtective Cap can then be put on the upper bushing of tdeadbreak junction to insulate that bushing. Since all bushinof the connector system are then insulated or grounded, aif the cable is grounded on the other end, it is safe to perfowork on the underground cable. See Figure 4 for a typicaU-OP Connector configuration.

    T-OP II Specification Information

    To specify a 900 A T-OP II System, include in your specification:n The system must fully comply with IEEE Std 386standard.n Must include an all copper alloy current path and copper-top

    connector.n System must include disconnecting back-off feature.n The connector system must provide operation with live line

    tools, direct conductor phasing and testing, visible ground andvisible break.n It must provide a location to add overvoltage arresters and access

    for direct conductor phasing or hipot testing of switch or cables.n Must be one-person hotstick operable and easy to install

    with proper torque such that concern for cross threading iseliminated.

    n Loadbreak reducing tap plug must include extended lengthstud, internal rotating nut and an alignment segment feature toeliminate cross threading of this compression connector andensure proper torque.

    n Loadbreak reducing tap plug must include latch indicator ring.n T-OP II Connector System base part number TP615 for 15 kV,

    TP625 for 25 kV and TP635 for 35 kV.

    Figure 3.T-OP II Connector Kit (TP6_5_) Components. For more details,see catalog sections 600-12, 600-32 and 600-52.

    LOADBREAK REDUCINGTAP PLUGLRTP615LRTP625LRTP635

    COPPERTOP COMPRESSIONCONNECTOR 15/16" THREADED

    HOLECC6C_ _ T CABLE

    ADAPTERCA625CA635

    T-BODYDT625DT635

    T-OP II STUDSTUD-T

    U-OP Specification Information

    To specify a 600 A U-OP Connector System that achieves avisible break and visible ground without having to move heavycable, include in your specification:

    n The system must fully comply with IEEE Std 386standard

    n The system must provide a visible break and visible groundwithout having to move 600 A cable.

    n A U-connection shall remain connected on the equipmenteven while performing repair to the underground cable toensure the interfaces are not exposed to the environment anthus potentially contaminated.

    n U-OP Connector System base part number UOP625 for bo15 and 25 kV.

    Figure 4.U-OP Connector Kit (UOP625) Components. For more detaisee catalog section 600-34.

    CURRENT PATH

    THROUGH U-OPCONNECTOR SYSTEM

    T-OP II CONNECTOR(not included, ordered

    separately)TP615 _ _TP625_ _

    2 BUSHING 600 ADEADBREAKJUNCTIONDJ625A2

    PARKINGSTAND

    U-CONNECTORAPPARABUSHIN

    2323Cooper Power Systems 23Cooper Power Systems

  • 8/10/2019 Catalogo Power System

    24/56

    BT-TAP and T-OP II Deadbreak Connector 15 kV and 25 kV

    S1 S3

    S2

    Bushing Adapter with LRTP (15 kV shown)

    S3 S2

    Standoff Bushing

    S35

    C

    A

    B

    A

    B

    D

    C

    PUSH-OP Standoff Bushing (15/25 kV shown)

    A

    B

    Standard Protective Cap

    A

    B

    Protective Cap for T-OP II and U-OP(15/25 kV shown)

    A

    D

    B S3S2

    BT-TAP and T-OP II Deadbreak Connector 35 kV

    A

    B

    PUSH-OP Deadbreak Connector (15 kV shown)

    BOL-T Deadbreak Connector

    S5

    S2 S4S3

    Dim. 15/25 kV 35 kV

    A 5.4" (137.2 mm) 5.4" (137.2 mm)

    B 5.6" (142.2 mm) 5.6" (142.2 mm)

    C 4.4" (111.8 mm) 4.4" (111.8 mm)

    S35 4.21" (106.9 mm) 5.2" (132.1 mm)

    Dim. 15/25 kV

    S1 4.93" (125.2 mm)

    S2 0.50" (12.7 mm)

    S3 8.29" (210.6 mm)

    Dim. 35 kV

    A 18.10" (459.7 mm)

    B 0.22" (5.59 mm)

    D 12.89" (327.4 mm)

    S2

    0.50" (12.7 mm)

    S3 12.46" (316.5 mm)

    S5 2.84" (72.1 mm)

    Dim. 15/25 kV 35 kV

    A 5.8" (147.3 mm) 6.8" (173 mm)

    B 3.25" (82.6 mm) 3.5" (88.9 mm)

    Dim. 15/25 kV 35 kV

    A 7.6" (193 mm) 8.66" (220 mm)

    B 3.25" (82.6 mm) 3.25" (82.6 mm)

    Dim. 15/25 kV 35 kV

    A 4.0" (101.6 mm) 5.80" (147.3 mm)

    B 2.37" (60.2 mm) 2.88" (73.2 mm)

    C 5.25" (133.4 mm) 6.0" (152.4 mm)

    D 5.50" (139.7 mm) 6.27" (159.3 mm)

    Dim. 15 kV 25 kV 35 kV

    A 12.8" 15.5" 17.9"

    (325.1

    mm)

    (393.7

    mm)

    (454.7

    mm)B 14.05" 14.05"

    (356.9mm)

    (356.9mm)

    Dim. 15/25 kV 35 kV

    S2 0.50" (13 mm) 0.50" (13 mm)

    S3 8.29" (210.6 mm) 12.46" (316.5 mm)

    Separable Splice

    S5

    S3CP S4S2S3IP

    15/25 kV

    Overall Length Deadend 11.24" (285 mm)

    Overall Length 2-Way Splice 19.97" (507 mm)

    Overall Length 3-Way Splice 28.70" (729 mm)

    Overall Length 4-Way Splice 37.43" (951 mm)

    S2 0.50" (12 mm)

    S3CP 8.23" (209 mm)

    S3IP 3.87" (98 mm)

    S4 1.50" (38 mm)

    S5 2.40" (61 mm)

    Dim. 15/25 kV 35 kV

    S2 0.50"(12.7 mm)

    0.50"(12.7 mm)

    S3 3.87"(98.3 mm) 4.97"(126 mm)

    S4 1.50"(38.1 mm)

    1.50"(38 mm)

    S5 2.4"(61 mm)

    2.84"(72 mm)

    S5

    24

    200 A Loadbreak & Deadbreak Connectors600 A Stacking Dimensions

    600 A Stacking Dimensions200 A Loadbreak & Deadbreak Connectors600 A Stacking Dimensions

  • 8/10/2019 Catalogo Power System

    25/56

    S10

    E

    5/8x 7/8" OBROUNDMOUNTING HOLES

    S11

    S7

    S9

    F

    G

    H

    B

    CD

    A

    Deadbreak Junction (35 kV shown)

    S7

    S9

    S10

    S11

    B

    E F

    G

    A

    M4

    S11

    0.56"(1 mm)

    2.00"(51 mm)

    1.4"(37 mm)

    MAX.MIN.

    MIN.MAX.

    MIN.MAX.

    CONFIGURATION - 2

    CONFIGURATION - 1

    CONFIGURATION - 3

    Deadbreak Junction (15/25 kV shown)

    TABLE 35 kV

    Number ofInterfaces

    Physical Dimensionsin. (mm)

    Mounting Dimensionsin. (mm)

    A B C D

    221.5"

    (546 mm)9.0"

    (229 mm)15.5"

    (394 mm12.5"

    (318 mm)

    327.5"

    (699 mm)15.0"

    (381 mm)21.5"

    (546 mm)18.5"

    (470 mm)

    433.5"

    (851 mm)21.0"

    (533 mm)27.5"

    (699 mm)24.5"

    (622 mm)

    Note: C and D are minimum and maximum stud centerline separations for mounting.

    Dim. 15/25 kV

    E 4.0" (101 mm)

    F 4.1" (102 mm)

    G 3.0" (76 mm)

    S7 0.75" (19 mm)

    S9 3.4" (86 mm)

    S10 6.2" (157 mm)

    S11 7.2" (182 mm)

    Dim. 35 kV

    E 6.0" (152 mm)F 6.2" (158 mm)

    G 3.0" (76 mm)

    H 3.8" (96 mm)

    S7 0.75" (19 mm)

    S9 5.55" (141 mm)

    S10 7.0" (178 mm)

    S11 10.4" (264 mm)

    TABLE 15/25 kV

    Number ofInterfaces

    PhysicalDimensions

    in./(mm)

    M4 Mounting Dimensions in./(mm)

    Configuration 1 Configuration 2 Configuration 3

    A B Min. Max. Min. Max. Min. Max.

    219.0"

    (483 mm)7.0"

    (178 mm)14.1 "

    (358 mm)16.9"

    (429 mm)9.7"

    (248 mm)12.5"

    (318 mm)5.6"

    (142 mm)8.4"

    (213 mm)

    323.0"

    (584 mm)11.0"

    (279 mm)18.6"

    (472 mm)21.4"

    (544 mm)14.2"

    (361 mm)17.0"

    (432 mm)10.1"

    (257 mm)12.9"

    (328 mm)

    427.1"

    (686 mm)15.0"

    (381 mm)24.1"

    (612 mm)26.9"

    (686 mm)19.7"

    (500 mm)22.5"

    (572 mm)15.6"

    (396 mm)18.4"

    (467 mm)

    Configuration 1. Both feet turned out.Configuration 2. One foot turned out, the other in.Configuration 3. Both feet turned in.

    Cooper Power Systems 2525

  • 8/10/2019 Catalogo Power System

    26/56

    We offer various types of splices for your underground needsn 200 A and 600 A systems. The EZ II One-Piece Splices at5, 25, and 35 kV include advantages for typical applicationsf repair, replacement, or extension of high voltagenderground cables. These all peroxide-cured EPDM rubberplices provide a highly reliable, permanent, fully shielded,nd submersible cable joint with a current rating equal tohat of the mating cable. EZ II Splices can be installed inonduit, direct buried or in vault applications. The EZ II Splicene meets or exceeds all requirements of IEEE Std 404

    tandard.We offer a full line of 600/900 A Separable Splice kits forpplication on feeder circuits. These use standard BOL-Type components along with a peroxide-cured EPDM rubberonnecting plug that allows for installation of multiple wayplices. Separable splices are used to splice multiple cablesr to deadend a single cable. The splices are rated for00 A (900 A ratings are available) and are suitable for theepair or extension of underground feeders. Separable spliceits meet or exceed the requirements of IEEE Std 386tandard.

    EZ II Splices

    The EZ II One-Piece Splices offer a number of features andbenefits, including:

    Easiest to Install The design features of the EZ II Splicencluding the tapered cable entrance, smooth bore, relievedonductive insert, and reformulated rubber provide forasier field installation. EZ II Splices have been shown to be0% easier to install than other manufacturers splices.

    Wide Range Taking The wide range taking cable entrancesre sized to accept all common cable insulation diameters.

    The wider cable ranges increase installation flexibility.

    Sure Grip The contoured EZ II Splice body provides anasy gripping location during installation.

    Long Term Reliability The EZ II Splice has successfullypassed all requirements of the IEEE Std 404 standardand

    ur exclusive field-proven multi-stress test to show the longerm reliability of the design.

    EZ ll Splice Specification Information

    To ensure you have the most reliable, economical,

    installation friendly premolded one-piece splice available, your

    specification for EZ II Splice should include:

    n Manufactured in full compliance with all applicable IEEE

    Std 404standard.

    n Manufactured from peroxide-cured EPDM rubber.

    n Tapered ribs of the inside diameter of the conductive

    insert.

    n Molded in compression connector diameters.

    n Conductive insert ends encapsulated with insulating

    rubber.

    Splices

    CAPCONNECTING

    PLUG

    THREADEDSTUD

    INSULATIONPLUG

    CAPACITIVETEST POINT

    CABLEADAPTER

    T-BODY

    COMPRESSIONCONNECTOR

    Typical components of a 600 A 2-way separable splice.

    Splice ApplicationsFCI

    SectionalizingCabinets

    Protective Cap

    Transformeror Switchgear

    Apparatus

    26

    200 A Loadbreak & Deadbreak Connectors

    26 Specifiers Guide: Components Master Catalog

    Splices

    Connecting Plug

    SeparableSplice

    BOL-T

    ConnectorCable Transition Module

    U-OP

    Junction Bars

    Deadbreak Junction

    T-OP II

  • 8/10/2019 Catalogo Power System

    27/56

    Catalog Section Description kV Class Base Part Number Notes

    700-15

    EZ IISplice

    15 kV SP15 CR6 CC4(see CR6 & CC4 Tables Below)

    1, 2, 3, 4

    25 kV SP25 CR6 CC4(see CR6 & CC4 Tables Below)

    1, 2, 3, 4

    35 kV SP35 CR6 CC4(see CR6 & CC4 Tables Below)

    1, 2, 3, 4

    1. For an all copper connector,change digit six from a 0 to a

    2. For a splice with a single-piecrejacketing kit, insert a S or a2-piecerejacketing kit, insert aas the ninth character in the panumber.

    3. For individuallypackagedproin a corrugated cardboard boxan X as the last character in tpart number.

    4. To splice different sized cablesto transition splice information catalog section 700-15.

    5. For 900 A rating(copper compnents) replace the A with a C

    6. For T-bodies with test points, a T directly after the base panumber.

    7. Studs are bagged and loose inhave studs permanently instaat the factory, add a P after tpoint designation (if applicable)after the base part number.

    8. Installation requires a standard

    hex key (HD625).

    9. To include 200 A loadbreakprotective cap, add a C as tlast character in the part numb

    TABLE CR6Cable Diameter (Insulation) Range

    Cable Diameter Range CABLERANGECODE

    VoltageClassInches Millimeters

    0.640-0.910 16.3-23.1 A 15 kV

    0.750-1.010 19.1-25.7 B 15 & 25kV0.890-1.140 22.6-29.0 C

    0.840-1.110 21.3-28.2 D15, 25 &

    35 kV1.000-1.310 25.4-33.3 E

    1.140-1.450 29.0-36.8 F

    TABLE CC4Conductor Size and Type

    Stranded orCompressed

    Compact orSolid CONDUCTOR

    CODEAWG mm2 AWG mm2

    #3 25 #2 35 001

    #2 35 #1 002

    #1 1/0 50 003

    1/0 50 2/0 70 004

    2/0 70 3/0 005

    3/0 4/0 95 006

    4/0 95 250 120 007

    250* 120 008* Compressed stranding only

    Use for Base Number(both tables)SP15 SP25 SP35

    TABLE 4Separable Splice Kits

    700-22700-31

    600 A Separable Splices(Kits Do Not Include

    Cable Adapters orCompressionConnector.

    Refer to 600 AReplacement Parts

    Page 21)

    15/25 kVDeadend Kit2-way Splice Kit

    3-way Splice Kit4-way Splice Kit

    SSPL625A1SSPL625A2

    SSPL625A3SSPL625A4

    5, 6, 7, 85, 6, 7, 8

    5, 6, 7, 85, 6, 7, 8

    35 kVDeadend Kit2-way Splice Kit3-way Splice Kit4-way Splice Kit

    SSPL635A1SSPL635A2SSPL635A3SSPL635A4

    5, 6, 7, 85, 6, 7, 85, 6, 7, 85, 6, 7, 8

    700-17700-37700-57

    T-OP II 600 A SeparableSplices with 200 A Tap

    (Kits Do Not IncludeRequired Threaded and

    Unthreaded CompressionConnectors or Cable

    Adapters. Refer to 600 AReplacement Parts Page

    21)

    15 kVT-OP II Deadend Kit SSPLT615A1T-OP II 2-way Splice Kit SSPLT615A2T-OP II 3-way Splice Kit SSPLT615A3T-OP II 4-way Splice Kit SSPLT615A4

    5, 6, 7, 8, 95, 6, 7, 8, 95, 6, 7, 8, 95, 6, 7, 8, 9

    25 kVT-OP II Deadend Kit SSPLT625A1T-OP II 2-way Splice Kit SSPLT625A2T-OP II 3-way Splice Kit SSPLT625A3T-OP II 4-way Splice Kit SSPLT625A4

    5, 6, 7, 8, 95, 6, 7, 8, 95, 6, 7, 8, 95, 6, 7, 8, 9

    35 kVT-OP II Deadend Kit SSPLT635A1T-OP II 2-way Splice Kit SSPLT635A2T-OP II 3-way Splice Kit SSPLT635A3T-OP II 4-way Splice Kit SSPLT635A4

    5, 6, 7, 8, 95, 6, 7, 8, 95, 6, 7, 8, 95, 6, 7, 8, 9

    Assembly

    Splice Kit Contents Order Separately (Refer to pg 21)

    T-BodyInsulating

    Plugw/Cap

    InsulatingPlug w/Cap

    and Stud

    ConnectingPlug

    w/Stud

    LoadbreakReducingTap Plug

    (Includes STUD-T)

    CableAdapter

    UnthreadedCompression

    Connector

    ThreadedCoppertopConnector

    Deadend

    1 1 1 1 1

    2-Way Splice

    2 1 1 1 2 2

    3-Way Splice

    3 1 1 2 3 3

    4-Way Splice

    4 1 1 3 4 4

    T-OP II Deadend

    1 1 1 1 1

    T-OP II 2-Way Splice

    2 1 1 1 2 1 1

    T-OP II 3-Way Splice

    3 1 2 1 3 2 1

    T-OP II 4-Way Splice

    4 1 3 1 4 3 1

    27Cooper Power Systems

    200 A Loadbreak & Deadbreak Connectors200 A Loadbreak & Deadbreak Connectors

  • 8/10/2019 Catalogo Power System

    28/56

    Our Metal Oxide Varistor Elbow (M.O.V.E.) and Parking Stand Arresters are usedn pad-mounted transformer and entry cabinets, vaults, switching enclosures andther installations to provide shielded deadfront arrester protection. These arrestersre designed for use with 200 A loadbreak interfaces to limit overvoltages tocceptable levels, protect equipment and extend cable life.

    The gapped structure of our VariGAP M.O.V.E. Arrester provides excellentemporary overvoltage (TOV) characteristics while the MOV disks offer rapid front-f-wave response with virtually no power follow current. Extensive laboratory testingnd over 15 years of field history have proven the hybrid VariGAP design offers the

    ollowing advantages over standard ungapped MOV arresters:Lower Discharge Voltage Characteristics

    Increased Thermal Capacity

    Improved Front-of-Wave Response

    Higher Temporary Overvoltage Capability

    To experience the benefits of our VariGAP M.O.V.E. Arrester, see the followingpecification information.

    POSI-BREAK M.O.V.E. Elbow Arrester

    The POSI-BREAK M.O.V.E. Arrester provides the same safety benefits of thePOSI-BREAK connector system w