Machine Safety
Jokab Safety products
Productivity and safety go hand in handJokab Safety was acquired by ABB in 2010. This gives us extra strength and a sales network in 120 countries. Our goal is to become
even better at supporting you as a customer through cooperation within ABB Jokab Safety globally and locally. The fact that the leading
power and automation technology company, ABB, and a leader in machine safety, Jokab Safety, have joined forces means a lot more
than just a new organizational chart. ABB has a huge footprint in the industry - from power supply to the control of each individual motor
- and has been delivering reliable solutions for decades that boost productivity in the industry. The acquisition of Jokab Safety means
the last building block is in place. We can now offer our customers tailored, turnkey solutions where machine safety is an integral and
value-enhancing component.
Jokab Safety offering: – Safety PLC
Pluto, Pluto AS-i, Gateways, Safe Encoder
– Safety controller Vital and Tina safety systems
– Safety relays
RT series, JSB series, safety timers, expansion relays
– Light curtains, light grids, light beams and scanner Focus II, Spot, Look
– Sensors, switches and locks
Eden, Sense, MKey, Magne, Dalton, Knox
– Control devices
JSHD4, Safeball, Fox2
– Emergency stop devices
Inca, Smile, EStrong, LineStrong
– Contact rails, bumpers and safety mats
– Fencing systems
Quick-Guard, SafeCad, Roller doors
Further information: „ABB Safety Handbook“ - Order code: 2TLC172001C0202
4 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Electronic Products and Relays
News
Universal Motor Controller UMC100.3 now availableThe intelligent ABB Motor Controllers for motor protection, motor control, fieldbus and Eth-
ernet communication and fault diagnosis. Due to the benefits it provides, the UMC is used
worldwide in many segments and in Projects with several thousand motor controllers. Beside
the proven UMC100 the new UMC100.3 offers even more capabilities like 24 V DC or
110-220 V AC/DC supply voltage and fieldbus communication interfaces.
CR-S Range pluggable small interface relaysThe pluggable interface relays of the CR-S Range are used for electrical isolation, amplifica-
tion and signal matching between the electronic controlling, e.g. PLC, iPC or field bus systems
and the sensor / actuator level. The CR-S Range combines the flexibility of a modular system
and the ability of switching high currents on a small footprint thus can be used in applications
where space saving is essential.
Thermistor motor protection relays in new housingThe thermistor motor protection relays of the CM-MSS range monitor the winding temperature
of motors which have PTC temperature sensors installed. These sensors are incorporated in
the motor windings thus measuring the motor heat directly. This direct temperature measure-
ment enables the thermistor motor protection relays to evaluate various motor conditions such
as overheating, overload and insufficient cooling. Depending on the product also the ATEX
approval is available for the use in hazardous areas.
The new housing provides two different connection terminals: The proven double-chamber
cage connection terminals and the Easy Connect Technology with Push-in terminals.
Grid feeding monitoring relays from the CM-UFD.Mx rangeThe multifunctional grid feeding monitoring relays of the CM-UFD range are designed to moni-
tor several grid parameters when feeding energy into the public grid. The intention is to trip a
section switch which is connected between the distributed generation and the public grid in
order to disconnect the distributed generation in case of problems (e.g. unstable grid), faults or
maintenance on the grid. Different monitoring functions such as 10-minutes average value, real
time over- and undervoltage as well as over- and underfrequency are configurable via the front
face display.
– CM-UFD.M22: Third party certificate confirming accordance with CEI 0-21: 2012-06 + CEI
0-21; V1: 2012-12 + A70 Terna
– CM-UFD.M31: Third party certificate confirming accordance with VDE-AR-N 4105: 2011-08;
BDEW, June 2008 “Technische Richtlinie – Erzeugungsanlagen am Mittelspannungsnetz”
including supplementary provisions of January 2013
– CM-UFD.M33: Factory certificate confirming accordance with Engineering Recommendation
G59 Issue 3 - September 2013; Engineering Recommendation G83 Issue 2 - December 2012
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5
1
5
3
7
2
6
4
Electronic Products and Relays
Table of contents
Electronic timers 1/1
Measuring and monitoring relays 2/1
Primary switch mode power supplies 3/1
Analog signal converters, serial data converters 4/1
Interface relays and optocouplers 5/1
Logic relays 6/1
Index 7/1
6 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Approvals and marks for the world market
Overview
ABB low-voltage switching devices are developed and produced in accordance with the applicable regulations as stated in the international IEC publica-
tions, the European EN specifications and the national VDE standards.
In most countries, low-voltage switching devices are produced according to such regulations under the responsibility of the manufacturers. This is why the
devices are not subject to further approval. However, for those devices which are intended for use in household or for public use our customers can reque-
st test reports of our internal laboratory for presentation to the various qualified local organizations. In other countries, approvals are prescribed by law.
For devices installed in ships, an approval issued by independent shipping companies, such as the GL, are demanded by the maritime insurance
companies.
Marks of conformity and examples of approvals (device-dependent)
International
CB scheme KThe CB (Certification Body) Scheme is a
system designed to facilitate international
trade by establishing mutual acceptance
of test reports among participating safety
certification organizations (the National Cer-
tification Bodies) in more than 30 countries.
The CB Scheme was established by the
International
Electrotechnical Committee for Conformity
Testing to Standards for Electrical
Equipment (IECEE).
Europe
Conformité Européen (CE) aAll devices which comply with the European
low voltage directive and which are intended
for sale within the European Union must
have the CE sign applied. All products in this
catalog are CE marked.
The CE sign must not be confused with a
certificate of quality issued by the EU. It is
solely used to confirm that the respective
product complies with the applicable
European directives *). The CE sign is part
of an administrative procedure to guarantee
free movement of goods within the Europe-
an Community.
*) Directives:
Low Voltage Directive 2006/95/EC
EMC Directive 2004/108/EC
Machinery Directive 98/37/EEC
Verband der Elektrotechnik
Elektronik Informationstechnik
(VDE)J
Applicable for technical instruments covered
by the German Gerätesicherheitsgesetz
(GSG) as well as for single parts and electri-
cal wiring devices.
Berufsgenossenschaft
der Feinmechanik und
Elektrotechnik (BGFE) MThe BG-PRÜFZERT sign is a voluntary
safety mark, awarded by the BGFE following
successful safety testing.
Explosion protection (EX) IExplosion protection acc. to
Directive 94/9/EG (ATEX 100a)
Swiss insurance institution
(SUVA)Q
Department accident prevention suvaPRO
Germanischer Lloyd (GL) CShipping approval
Lloyds Register PShipping approval
Russia
In Russia, low-voltage switching devices are
subject to certification and have to be provi-
ded with a sign.
Eurasian Conformity REAC certification is mandatory for many pro-
ducts. This certification is based on a safety
test (IEC standards with Russia-
specific deviations) and an EMC test.
Russian Maritime Register of
Shipping RMRS LShipping approval
Australia, New Zealand
C-Tick Mark bThe C-Tick Mark certifies compliance with
the Australian EMC requirements. The Mark
is also recognized in New Zealand.
China
CCC (China Compulsory
Certification) EIn China the CCC certification mark is a
compulsory certification mark in the field of
safety and quality for products sold on the
Chinese market.
North America
Canadian and US standards are more or
less equivalent but considerably differ from
the IEC and VDE regulations.
USA
Underwriters Laboratories (UL)
Listing BReleased for installation in systems and for
sale as individual component in the USA.
Recognition GReleased for installation in systems, if the
respective system has been completely
mounted and wired by qualified personnel.
Canada
Canadian Standards
Association (CSA) F
USA and Canada
The combined UL signs for the USA and
Canada are recognized by the authorities of
both countries. Devices with this certificate
meet the requirements of both countries.
Listing A
Recognition H
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 7
Find Electronic Products and Relays product information and
documentation on our web page
The following steps will guide you to the documentation and product search section of the Electronic Products and Relays portfolio on www.ABB.com.
Enter http://new.abb.com/low-voltage/products/epr in your internet browser.
You will be redirected to the following page:
Latest information about the Electronic Products and Relays product range could be found in the Highlights section.
In the lower area of the web page you can find the Our offering section.
The assortment of the Electronic Products and Relays range is listed here as shown in the screenshot below:
Select the register of the relevant product group to see all the products related to the product group.
Choose a product range from which you want to see the documentation or from which you want to choose a specific product.
In this example the CT-S range from the register Electronic timers has been selected as shown on the screenshot.
8 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Find Electronic Products and Relays product information and
documentation on our web page
You will be redirected to the following page:
Latest information about the Electronic Products and Relays product range could be found in the Highlights sections.
In the lower area of the web page you can find the Products and documents section.
The functions to choose a product or a document are listed here as in the screenshot below:
To search for a product continue on page 9.To search for documentation continue on page 10.
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 9
Find Electronic Products and Relays product information and
documentation on our web page
How to find the right product
Click on Filters to see the different search attributes for the selected product range.
The filter section will be expanded as shown below.
The different product filters are shown.
Click on the filter attribute to continue the product search process.
In this example Output has been chosen.
In the right part mark the corresponding check box to narrow down the search. You can also select several check boxes.
Click on Apply to submit your filter.
The search results are now listed according to your selection.
Proceed this approach with different filters until the right product is listed.
Click on the product in the Result section to get the dedicated product information listed in your browser.
10 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Find Electronic Products and Relays product information and
documentation on our web page
How to find the right documentation
Click on Documents to see the different types of documentation for the product.
The document section will be expanded as shown below.
On the left side select the type of document related to the product. In the example Popular documents has been selected.
In the right area click on the document related to the product.
The document is opened or downloaded, depending on the individual browser settings.
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 11
EPR Catalog 2015
Notes
1/1 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
1
Electronic timers
Product group picture
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 1/2
1
Electronic timers
Table of contents
Electronic timers
Table of contents 1/2
Overview 1/3
Approvals and marks 1/4
CT-D range 1/5
Table of contents 1/6
Benefits and advantages 1/7
Ordering details 1/8
Function diagrams 1/9
Connection diagrams 1/12
Technical data 1/13
Technical data, Technical diagrams 1/15
Wiring notes, Dimensional drawings 1/16
CT-E range 1/17
Table of contents 1/18
Benefits and advantages 1/19
Ordering details 1/20
Function diagrams 1/22
Connection diagrams 1/27
Connection diagrams, Technical diagrams 1/28
Technical data 1/29
Wiring notes, Dimensional drawings 1/31
CT-S range 1/33
Table of contents 1/34
Benefits and advantages 1/35
Ordering details - multifunctional 1/37
Ordering details - singlefunctional 1/38
Ordering details - Accessories 1/39
Function diagrams 1/41
Connection diagrams 1/49
Technical data 1/52
Technical diagrams 1/55
Wiring notes, Dimensional drawings 1/56
1/3 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
1
CT-S rangeCT-E rangeCT-D range
Timing function multifunctional single-functional multifunctional single-functional multifunctional single-functional
A ON-delay CT-MFD CT-ERD CT-MFE, CT-MKE
CT-ERE, CT-EKE
CT-MVS, CT-MFS, CT-MBS, CT-WBS
CT-ERS
B OFF-delay CT-MFD CT-AHD CT-MFE CT-AHE, CT-ARE, CT-AKE
CT-MVS, CT-MFS, CT-MBS
CT-APS, CT-AHS, CT-ARS
AB ON- and OFF-delay CT-MVS, CT-MXS, CT-MFS, CT-MBS
CA Impulse-ON CT-MFD CT-VWD CT-MFE, CT-MKE
CT-VWE CT-MVS, CT-MFS, CT-MBS, CT-WBS
CB Impulse-OFF CT-MFD CT-AWE CT-MVS, CT-MFS, CT-MBS
CE Impulse-ON and OFF CT-MXS
DA Flasher starting with ON CT-MFD CT-EBD CT-MFE, CT-MKE
CT-MFS, CT-MBS, CT-WBS
DB Flasher staring with OFF CT-MFD CT-MFE, CT-MKE
CT-EBE CT-MFS, CT-MBS, CT-WBS
DE Flasher starting with ON or
OFF
CT-MVS
ED Pulse generator starting with
ON or OFF
CT-TGD CT-MXS
H Pulse former CT-MFD CT-MFE CT-MVS, CT-MFS, CT-MBS
F Star-delta change-over CT-SDD, CT-SAD
CT-SDS
FC Star-delta change-over with
impulse
CT-SDE CT-MVS.2x, CT-MFS, CT-MBS
FA Star-delta change-over
twice ON-delayed
CT-YDE
A+ AC BC G
further functions
(depending on device)
CT-MVS, CT-MXS, CT-MFS, CT-MBS, CT-WBS
Technical data (extract)
Time ranges 7 (0.05 s - 100 h)
CT-SDD, CT-SAD:
4 (0.05 s - 10 min)
Multifunction devices:
8 (0.05 s - 100 h)
Single-function devices:
5 single ranges (0.05-1 s, 0.1-10 s,
0.3-30 s, 3-300 s, 0.3-300 min)
10 (0.05 s - 300 h)
CT-ARS, CT-SDS:
7 (0.05 s- 10 min)
Control supply voltage Wide and multi ranges Wide ranges Single and dual
ranges
Wide, multi and single ranges
Type and number of contacts 1 or 2 c/o contacts
CT-SDD, CT-SAD: 2 n/o contacts
1 c/ o contact
CT-SDE: 1 n/o contact and 1 n/c
contact
CT-MKE, CT-EKE, CT-AKE: 1 thyristor
1 or 2 c/o contacts
CT-MVS.21, CT-MFS, CT-MBS:
2nd c/o contact selectable as inst.
contact
CT-SDS: 2 n/o contacts
Control inputs voltage-related triggering,
polarized, capable of switching a
parallel load
voltage-related triggering, polarized
CT-MFE, CT-AHE, CT-AWE:
with auxiliary voltage
voltage-related triggering, non-
polarized, capable of switching a
parallel load
CT-MFS, CT-MBS, CT-AHS:
volt-free triggering
Electronic timers
Overview
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 1/4
1
Electronic timers
Approvals and marks
� existing
� pending
CT-D
Approvals CT-M
FD
.12
CT-M
FD
.21
CT-E
RD
.12
CT-E
RD
.2
2
CT-A
HD
.12
CT-A
HD
.22
CT-V
WD
.12
CT-E
BD
.12
CT-T
GD
.12
CT-T
GD
.22
CT-S
DD
.22
CT-S
AD
.22
A UL 508, CAN/CSA C22.2 No.14 � � � � � � � � � � � �
K CB scheme � � � � � �
EAC � � � � � � � � � � � �
E CCC � � � � � � � � � � � �
L RMRS � � � � � � � � � �
Marks
a CE � � � � � � � � � � � �
b RCM � � � � � � � � � � � �
� existing
� pending
CT-E
Approvals CT-M
FE
CT-E
RE
CT-A
HE
CT-A
RE
CT-V
WE
CT-A
WE
CT-E
BE
CT-Y
DE
CT-S
DE
CT-M
KE
CT-E
KE
CT-A
KE
A UL 508, CAN/CSA C22.2 No.14 � � � � � � � � � � � �C GL � � � � � � � � � � � �K CB scheme � � � � � � � � �
EAC � � � � � � � � � � � �E CCC � � � � � � � � �L RMRS � � � � � � � � � � � �
Marks
a CE � � � � � � � � � � � �b RCM � � � � � � � � � � � �
� existing
� pending
CT-S
Approvals CT-M
VS
.12
S/P
CT-M
VS
.2xS
/P
CT-M
XS
.22
S/P
CT-M
FS
.21
S/P
CT-M
BS
.22
S/P
CT-W
BS
.22
S/P
CT-E
RS
.12
S/P
CT-E
RS
.2xS
/P
CT-A
PS
.12
S/P
CT-A
PS
.2xS
/P
CT-A
HS
.22
S/P
CT-A
RS
.11
S/P
CT-A
RS
.21
S/P
CT-S
DS
.2xS
/P
A UL 508, CAN/CSA C22.2 No.14 � � � � � � � � � � � � � �C GL � � � � � � � � � � � � � �
EAC � � � � � � � � � � � � � �K CB scheme � � � � � � � � � � � � � �E CCC � � � � � � � � � � � � � �L RMRS � � � � � � � � � � � � � �
Rail applications 1) � � � � � �Marks
a CE � � � � � � � � � � � � � �b RCM � � � � � � � � � � � � � �
1) Applicable in rail application following the latest standards for rail applications. Further information are available in our rail segment brochure 2CDC110084B0201.
1/5 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
1
CT-D range
Product group picture
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 1/6
1
CT-D range
Table of contents
CT-D Range
Benefits and advantages 1/7
Ordering details 1/8
Function diagrams 1/9
Connection diagrams 1/12
Technical data 1/13
Technical data, Technical diagrams 1/15
Wiring notes, Dimensional drawings 1/16
1/7 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
1
CT-D range
Benefits and advantages
Operating controls
1 LEDs for status indication U - green LED: V control supply voltage applied
W timing
R, R1, R2 - yellow LED: V output relay energized
2 Time range adjustment
3 Fine adjustment of the time delay
4 Preselection of the timing function
multifunctional single-functional
Direct reading scalesDirect setting of the time delay without any additional
calculation provides accurate time delay adjustment.
LEDs for status indicationAll actual operational states are displayed by front-face LEDs,
thus simplifying commissioning and troubleshooting.
Switching currentsThe CT-D range timers allow an output load of up to 6 A on
devices with 1 c/o contact and up to 5 A on devices with
2 c/o contacts.
Connection terminalsWide terminal spacing allows connection of wires:
2 x 1.5 mm² (2 x 16 AWG) with wire end ferrules or 2 x 2.5
mm² (2 x 14 AWG) without ferrules.
Width 17.5 mmWith their width of 17.5 mm only, the CT-D range timers are
ideally suited for installation in distribution panels.
17.5 mm
Characteristics – Diversity:
– 2 multifunction timers
– 10 single-function timers
– Control supply voltages:
– Wide range: 12-240 V AC/DC
– Multi range: 24-48 V DC, 24-240 V AC
– 7 time ranges from 0.05 s to 100 h or
4 time ranges from 0.05 s to 10 min
– Width of only 17.5 mm
– Light-grey housing in RAL 7035
– Devices with:
1 c/o contact (250 V / 6 A) or 2 c/o contacts (250 V / 5 A)
Control input: voltage-related triggering, polarized,
capable of switching parallel loads
– Approvals / Marks (partly pending, details see page 1/4)
– A, K1), E, , L / a, b1) Only for devices with 1 c/o (SPDT) contact
Benefits
4
2
3
1
2
3
2C
DC
25
3 0
66
F0
00
6
2C
DC
25
3 1
32
F0
00
6
2C
DC
25
3 0
33
F0
00
4
2C
DC
25
3 0
21
F0
00
4
1
1
2
2
3
3
4
4
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 1/8
1
Synonyms
used expression alternative expression(s) used expression alternative expression(s)
1 c/o contact SPDT voltage-related wet / non-floating
2 c/o contacts DPDT volt-free dry / floating
2C
DC
25
1 0
89
F0
00
62
CD
C 2
51
09
1 F
00
06
CT-MFD.12
CT-ERD.22
A ON-delay
B OFF-delay
CA Impulse-ON
CB Impulse-OFF
DA Flasher starting with ON
DB Flasher staring with OFF
H Pulse former
ED Pulse generator
F Star-delta change-over
CT-D range
Ordering details
1) Functions: ON-delay, OFF-delay with auxiliary voltage, Impulse-ON, Impulse-OFF with auxiliary voltage,
Flasher starting with ON, Flasher starting with OFF, Pulse former2) ON and OFF times adjustable independently: 2 x 7 time ranges 0.05 s - 100 h3) Transition time 50 ms fixed4) Transition time adjustable
Description
The CT-D range in MDRC design with a width of only 17.5 mm fits into all domestic installation
and distribution panels.
The CT-D range represents a link between industry and the installation types. For maximum
flexibility in operation, 10 single-function as well as 2 multifunction devices with 7 timing
functions are available. The devices offer 4 or 7 time ranges from 0.05 seconds up to 100
hours. Their wide input range allows the use in applications worldwide.
Ordering detailsTiming function
Rated control supply voltage
Time ranges Con-trol input
Output Type Order code Price
1 pce
Weight(1 pce)
kg (lb)
Multifunc-tional1)
24-240 V AC 24-48 V DC
7 (0.05 s - 100 h)
� 1 c/o CT-MFD.12 1SVR500020R00000.060 (0.132)
Multifunc-tional1)
12-240 V AC/DC
7 (0.05 s - 100 h)
� 2 c/o CT-MFD.21 1SVR500020R11000.065 (0.143)
ON-delay
24-240 V AC 24-48 V DC
7 (0.05 s - 100 h)
- 1 c/o CT-ERD.12 1SVR500100R00000.060 (0.132)
- 2 c/o CT-ERD.22 1SVR500100R01000.065 (0.143)
OFF-delay
� 1 c/o CT-AHD.12 1SVR500110R00000.060 (0.132)
� 2 c/o CT-AHD.22 1SVR500110R01000.065 (0.143)
Impulse-ON
-
1 c/o
CT-VWD.12 1SVR500130R0000
0.060 (0.132)Flasher
starting with ON
- CT-EBD.12 1SVR500150R0000
Pulse generator
2×7 (0.05 s - 100 h)
� CT-TGD.122) 1SVR500160R00000.060 (0.132)
� 2 c/o CT-TGD.222) 1SVR500160R01000.065 (0.143)
Star-delta change-over
4 (0.05 s - 10 min)
-
2 c/o
CT-SDD.223) 1SVR500211R01000.065 (0.143)
- CT-SAD.224) 1SVR500210R0100
� Control input with voltage-related triggering
- no triggering
1/9 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
1 RemarksLegendG Control supply voltage not applied / Output contact open
B Control supply voltage applied / Output contact closed
A1-Y1/B1 Control input with voltage-related triggering
Terminal designations on the device and in the diagramsThe 1st c/o contact is always designated 15-16/18.
The 2nd c/o contact is designated 25-26/28.
The n/o contacts of the star-delta timers are designated with
17-18 and 17-28.
Control supply voltage is always applied to terminals A1-A2.
Function of the yellow LEDThe yellow LED R glows as soon as the output relay
energizes and turns off when the output relay de-energizes.
A ON-delay (Delay on make) CT-ERD, CT-MFD
B OFF-delay with auxiliary voltage (Delay on break) CT-AHD, CT-MFD
This function requires continuous control supply voltage for
timing.
Timing begins when control supply voltage is applied.
The green LED flashes during timing. When the selected
time delay is complete, the output relay energizes and the
flashing green LED turns steady.
If control supply voltage is interrupted, the output relay de-
energizes and the time delay is reset.
Control input A1-Y1/B1 of the CT-MFD is disabled when this
function is selected.
This function requires continuous control supply voltage for
timing. If control input A1-Y1/B1 is closed, the output relay
energizes immediately. If control input A1-Y1/B1 is opened,
the time delay starts. The green LED flashes during timing.
When the selected time delay is complete, the output relay
de- energizes and the flashing green LED turns steady.
If control input A1-Y1/B1 recloses before the time delay is
complete, the time delay is reset and the output relay does
not change state. Timing starts again when control input
A1-Y1/B1 re-opens.If control supply voltage is interrupted,
the output relay de-energizes and the time delay is reset.
A1-A2
15-16, 25-26 15-18, 25-28
t < t
2CD
C 2
52 1
06 F
0206
green LED
t = adjusted time delay
A1-A2
15-16, 25-26 15-18, 25-28
t
A1-Y1/B1
< t
2CD
C 2
52 1
07 F
0206
green LED
t = adjusted time delay
CT-D range
Function diagrams
CA Impulse-ON (Interval) CT-VWD, CT-MFD
CB Impulse-OFF with auxiliary voltage (Trailing edge interval) CT-MFD
This function requires continuous control supply voltage for
timing. The output relay energizes immediately when control
supply voltage is applied and de-energizes after the set pulse
time is complete. The green LED flashes during timing. When
the selected pulse time is complete, the flashing green LED
turns steady. If control supply voltage is interrupted, the
output relay de-energizes and the time delay is reset. Control
input A1-Y1/B1 of the CT-MFD is disabled when this function
is selected.
This function requires continuous control supply voltage for
timing. If control supply voltage is applied, opening con-
trol input A1-Y1/B1 energizes the output relay immediately
and starts timing. The green LED flashes during timing.
When the selected pulse time is complete, the output relay
de-energizes and the flashing green LED turns steady.
Closing control input A1-Y1/B1, before the time delay is
complete, de-energizes the output relay and resets the time
delay. If control supply voltage is interrupted, the output
relay de-energizes and the time delay is reset. A1-A2
15-16, 25-26 15-18, 25-28
t < t
2CD
C 2
52 1
08 F
0206
green LED
t = adjusted pulse time
A1-A2
15-16, 25-26 15-18, 25-28
t
A1-Y1/B1
< t
2CD
C 2
52 1
09 F
0206
green LED
t = adjusted pulse time
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 1/10
1
DA Flasher, starting with the ON time (Recycling equal times, ON first) CT-EBD, CT-MFD
DB Flasher, starting with the OFF time (Recycling equal times, OFF first) CT-MFD
Applying control supply voltage starts timing with symmetrical
ON & OFF times. The cycle starts with an ON time first. The
ON & OFF times are displayed by the flashing green LED,
which flashes twice as fast during the OFF time.
If control supply voltage is interrupted, the output relay
de-energizes and the time delay is reset.
Control input A1-Y1/B1 of the CT-MFD is disabled when this
function is selected.
Applying control supply voltage starts timing with symmetrical
ON & OFF times. The cycle starts with an OFF time first. The
ON & OFF times are displayed by the flashing green LED,
which flashes twice as fast during the OFF time.
If control supply voltage is interrupted, the output relay
de-energizes and the time delay is reset.
Control input A1-Y1/B1 of the CT-MFD is disabled when this
function is selected.
A1-A2
15-16, 25-26 15-18, 25-28
t t
2CD
C 2
52 0
29 F
0206
green LED
t = adjusted flashing time
A1-A2
15-16, 25-26 15-18, 25-28
t t
2CD
C 2
52 0
30 F
0206
green LED
t = adjusted flashing time
CT-D range
Function diagrams
H Pulse former (Single shot) CT-MFD
E Pulse generator, starting with the ON or OFF time (Recycling unequal times, ON or OFF first) CT-TGD
This function requires continuous control supply voltage for
timing.
Closing control input A1-Y1/B1 energizes the output relay
immediately and starts timing. Operating the control contact
switch A1-Y1/B1 during the time delay has no effect. The
green LED flashes during timing. When the selected ON time
is complete, the output relay de-energizes and the flashing
green LED turns steady. After the ON time is complete, it
can be restarted by closing control input A1-Y1/B1.
If control supply voltage is interrupted, the output relay
de-energizes and the time delay is reset.
This function requires continuous control supply voltage for
timing.
Applying control supply voltage, with open control input
A1-Y1/B1, starts timing with an ON time first. Applying
control supply voltage, with closed control input A1-Y1/B1,
starts timing with an OFF time first. The ON & OFF times are
displayed by the flashing green LED, which flashes twice as
fast during the OFF time.
The ON & OFF times are independently adjustable.
If control supply voltage is interrupted, the output relay
de-energizes and the time delay is reset.A1-A2
15-16, 25-26 15-18, 25-28
t t
A1-Y1/B1
2CD
C 2
52 1
10 F
0206
green LED
t = adjusted pulse time
A1-A2
A1-Y1/B1
15-16, 25-26 15-18, 25-28
t1 t1t2 t2
2CD
C 2
52 1
11 F
0206
green LED
t1 = adjusted OFF timet2 = adjusted ON time
1/11 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
1
K1T
K1T
K3
K3
Y � N
K2
K2
K2
L1
N
F3
F2
95
96
21
22
22
21
A1
A2
A1
A2
A1
A2
A1
A2
22
21
13
14
17
18
17
28
13
14
13
14
53
54
S10
IS2
K1
K1
K1
2CD
C 2
52 1
28 F
0b06
-K1-K3
L1
-F1
1
2
95
96
97
98
L2
3
4
L3
5
6
1
2
3
4
5
6
1
2
3
4
5
6-K2
-F2
1
2
3
4
5
6
1
3
5
2
4
6
M
3 ~
W2V2U2
W1V1U1
-M1
2CD
C 2
52 0
12 F
0b07
F Star-delta change-over (Star-delta starting) CT-SDD, CT-SAD
This function requires continuous control supply voltage for
timing.
Applying control supply voltage to terminals A1-A2,
energizes the star contactor connected to terminals 17-18
and begins the set starting time t1. The green LED flashes
during timing. When the starting time is complete, the first
output contact de-energizes the star contactor.
Now, the transition time t2 starts. When the transition time
is complete, the second output contact energizes the
delta contactor connected to terminals 17-28. The delta
contactor remains energized as long as control supply
voltage is applied to the unit.
A1-A2
t1 t2
2CD
C 2
52 1
12 F
0206
green LED
t1 = adjusted starting timet2 = transition timeCT-SDD: t2 = 50 msCT-SAD: t2 adjustable
17-18
17-28
Power circuit diagramControl circuit diagram
CT-D range
Function diagrams
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 1/12
1CT-MFD.21 CT-MFD.12 A CT-ERD.12
B CT-AHD.22
A1
A1
28
28
26
26
A218 16 Y1/B1
A2
15
25
1816
15
25
Y1/B1
2CD
C 2
52 1
13 F
0b06
A1
A1
28
28
26
26
A218 16 Y1/B1
A2
15
25
1816
15
25
Y1/B1
2CD
C 2
52 1
16 F
0b06
A1
A1
28
28
26
26
A218 16
A2
15 25
25
1816
15
2CD
C 2
52 1
15 F
0b06
A CT-ERD.22
B CT-AHD.12 CA CT-VWD.12 DA CT-EBD.12
ED CT-TGD.22
A1
A1
28
18
26
16
A218 16 Y1/B1
A2
15
15
2826
25
25
Y1/B1
2CD
C 2
52 1
18 F
0b06 A1
A1
A2 18 28
17
17
28 18 A2
2CD
C 2
52 1
60 F
0b06
ED CT-TGD.12 F CT-SDD.22 F CT-SAD.22
A1
A1
18
18
16
16
A2
A2
15
15
Y1/B1
Y1/B1
2CD
C 2
52 1
14 F
0b06 A1
A1
18
18
16
16
A2
A2
15
15
2CD
C 2
52 1
77 F
0b05
A1
A1
18
18
16
16
A2
A2
15
15
Y1/B1
Y1/B1
2CD
C 2
52 1
17 F
0b06 A1
A1
18
18
16
16
A2
A2
15
15 2C
DC
252
179
F0b
05 A1
A1
18
18
16
16
A2
A2
15
15
2CD
C 2
52 1
80 F
0b05
A1
A1
18
18
16
16
A2
A2
15
15
Y1/B1
Y1/B1
2CD
C 2
52 1
19 F
0b06 A1
A1
A2 18 28
17
17
28 18 A2
2CD
C 2
52 1
60 F
0b06
CT-D range
Connection diagrams
A1-A2 Supply: 12-240 V AC/DC
A1-Y1/B1 Control input
15-16/18 1. c/o contact
25-26/28 2. c/o contact
A1-A2 Supply: 24-48 V DC or 24-240 V AC
A1-Y1/B1 Control input
15-16/18 1. c/o contact
A1-A2 Supply: 24-48 V DC or 24-240 V AC
A1-Y1/B1 Control input
15-16/18 1. c/o contact
A1-A2 Supply: 24-48 V DC or 24-240 V AC
A1-Y1/B1 Control input
15-16/18 1. c/o contact
A1-A2 Supply: 24-48 V DC or 24-240 V AC
15-16/18 1. c/o contact
25-26/28 2. c/o contact
A1-A2 Supply: 24-48 V DC or 24-240 V AC
A1-Y1/B1 Control input
15-16/18 1. c/o contact
25-26/28 2. c/o contact
A1-A2 Supply: 24-48 V DC or 24-240 V AC
A1-Y1/B1 Control input
15-16/18 1. c/o contact
25-26/28 2. c/o contact
A1-A2 Supply: 24-48 V DC or 24-240 V AC
17-18 1. n/o contact (star contactor)
17-28 2. n/o contact (delta contactor)
A1-A2 Supply: 24-48 V DC or 24-240 V AC
17-18 1. n/o contact (star contactor)
17-28 2. n/o contact (delta contactor)
A1-A2 Supply: 24-48 V DC or 24-240 V AC
15-16/18 1. c/o contact
A1-A2 Supply: 24-48 V DC or 24-240 V AC
15-16/18 1. c/o contact
A1-A2 Supply: 24-48 V DC or 24-240 V AC
15-16/18 1. c/o contact
1/13 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
1
CT-D range
Technical data
Data at Ta = 25 °C and rated values, unless otherwise indicated
CT-D with 1 c/o contact
CT-D with 2 c/o contacts
CT-MFD.21
Input circuit - Supply circuitRated control supply voltage U
s24-240 V AC / 24-48 V DC 12-240 V AC/DC
Rated control supply voltage US tolerance -15...+10 %
Rated frequency DC or 50/60 Hz
Frequency range AC 47-63 Hz
Typical current / power consumption see data sheet
Power failure buffering time min. 20 ms
Release voltage > 10 % of the minimum rated control supply voltage Us
Input circuit - Control circuitControl input, control function A1-Y1/B1 start timing external
Kind of triggering voltage-related triggering
Resistance to reverse polarity yes
Parallel load / polarized yes / yes
Maximum cable length to the control inputs 50 m - 100 pF/m
Minimum control pulse length 20 ms
Control voltage potential see rated control supply voltage
Current consumption of the control input see data sheet
Timing circuitTime ranges 7 time ranges 0.05 s - 100 h 1.) 0.05-1 s 2.) 0.5-10 s 3.) 5-100 s 4.) 0.5-10 min
5.) 5-100 min 6.) 0.5-10 h 7.) 5-100 h
4 time ranges 0.05 s - 10 min (CT-SDD, CT-SAD) 1.) 0.05-1 s 2.) 0.5-10 s 3.) 5-100 s 4.) 0.5-10 min
Recovery time < 50 ms
Accuracy within the rated control supply voltage tolerance �t < 0.005 % / VAccuracy within the temperature range �t < 0.06 % / °CRepeat accuracy (constant parameters) �t < ± 0.5 %Setting accuracy of time delay IEC/EN 61812-1 ± 10% of full-scale value
Star-delta transition time CT-SDD / CT-SAD fixed 50 ms / adjustable: 20 ms, 30 ms, 40 ms, 50 ms, 60 ms, 80 ms or 100 ms
Star-delta transition time tolerance CT-SDD / CT-SAD ±3 ms
Indication of operational statesControl supply voltage / timing U: green LED V: control supply voltage applied
W: timingRelay energized (1 c/o contact / 2 c/o contacts or inst. contact)
R: yellow LED V: output relay energized
Operating elements and controlsAdjustment of the time range front-face rotary switch, direct reading scales
Fine adjustment of the time value front-face potentiometer
Preselection of the timing function at multifunction devices front-face rotary switch, direct reading scales
Adjustment of the transition time CT-SAD front-face potentiometer
Output circuitKind of output 15-16/18 Relay, 1 c/o contact -
15-16/18; 25-26/28 - Relay, 2 c/o contacts
17-18; 17-28 Relay, 2 n/o contacts (CT-SDD, CT-SAD)
Contact material AgNi alloy, Cd free
Rated operational voltage Ue
250 V
Minimum switching voltage / minimum switching current 12 V / 100 mA
Maximum switching voltage / maximum switching current 250 V AC / 6 A 250 V AC / 5 A
Rated operational current Ie
(IEC/EN 60947-5-1 ) AC-12 (resistive) at 230 V 6 A 5 A
AC-15 (inductive) at 230 V 3 A 3 A n/o: 3 A n/c: 0.75 A
DC-12 (resistive) at 24 V 6 A 5 A
DC-13 (inductive) at 24 V 2 A 2 A 1 A
AC rating (UL 508) utilization category (Control Circuit Rating Code) B 300 n/o: B 300 n/c: C 300
max. rated operational voltage 300 V AC
Maximum continuous thermal current at B300 5 A n/o: 5 A
Maximum continuous thermal current at C300 - n/c: 2.5 A
max. making/breaking apparent power at B300 3600 VA / 360 VA n/o: 3600/360 VA
max. making/breaking apparent power at C300 - n/c: 1800/180 VA
Mechanical lifetime 30 x 106 switching cycles
Electrical lifetime 0.1 x 106 switching cycles
Max. fuse rating to achieve short-circuit protection (IEC/EN 60947-5-1)
n/c contact 6 A fast-acting
n/o contact 10 A fast-acting 6 A fast-acting
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 1/14
1
CT-D range
Technical data
CT-D with 1 c/o contact
CT-D with 2 c/o contacts
CT-MFD.21
General data
Mean time between failures (MTBF) on request
Duty time 100%
Dimensions (W x H x D) 17.5 x 70 x 58 mm (0.69 x 2.76 x 2.28 in)
17.5 x 80 x 58 mm (0.69 x 3.15 x 2.28 in)
Weight see ordering details
Mounting DIN rail (IEC/EN 60715), snap-mounting without any tool
Mounting position any
Minimum distance to other units horizontal / vertical no / no
Degree of protection housing / terminals IP50 / IP20
Electrical connectionWire size fine-strand with(out) wire end ferrule 2 x 0.5-1.5 mm2 (2 x 20-16 AWG)
1 x 0.5-2.5 mm2 (1 x 20-14 AWG)
rigid 2 x 0.5-1.5 mm2 (2 x 20-16 AWG)1 x 0.5-4 mm2 (1 x 20-12 AWG)
Stripping length 7 mm (0.28 in)
Tightening torque 0.5-0.8 Nm (4.43-7.08 lb.in)
Environmental dataAmbient temperature range operation / storage -20 ... +60 °C / -40 ... +85 °C
Climatic class IEC/EN 60068-2-30 3K3
Relative humidity range 25-85%
Shock (half-sine) IEC/EN 60068-2-27 150 m/s2, 11 ms
Isolation dataRated impulse withstand voltage U
imp
between all isolated circuitsIEC/EN 60664-1 type test: 4 kV; 1.2/50 μs
Pollution category IEC/EN 60664-1 3
Overvoltage category IEC/EN 60664-1 III
Rated insulation voltage Ui
input circuit / output circuit 300 V
output circuit 1 / output circuit 2 not available 300 V 300 V
Basic insulation (IEC/EN 61140) input circuit / output circuit 300 V
Protective separation (IEC/EN 61140, EN 50178)
input circuit / output circuit 250 V
Power-frequency withstand voltage test (test voltage)
between all isolated circuits routine test: 2.5 kV; 50 Hz; 1 stype test: 2.5 kV; 50 Hz; 60 s
StandardsProduct standard IEC/EN 61812-1
Low Voltage Directive 2006/95/EC
EMC Directive 2004/108/EC
RoHS Directive 2011/65/EC
Electromagnetic compatibilityInterference immunity to IEC/EN 61000-6-1, IEC/EN 61000-6-2
electrostatic discharge IEC/EN 61000-4-2 Level 3 (6 kV / 8 kV)radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 Level 3 (10 V / m)electrical fast transient / burst IEC/EN 61000-4-4 Level 3 (2 kV / 5 kHz)surge IEC/EN 61000-4-5 Level 4 (2 kV L-L)conducted disturbances, induced by radio-frequency fields IEC/EN 61000-4-6 Level 3 (10 V)
Interference emission IEC/EN 61000-6-3, IEC/EN 61000-6-4high-frequency radiated IEC/CISPR 22, EN 55022 Class Bhigh-frequency conducted IEC/CISPR 22, EN 55022 Class B
„Approvals and marks“ see page 1/4.
1/15 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
1
CT-D range
Technical data, Technical diagrams
CT-D.2x CT-D.2x
Derating factor F for inductive AC load
Contact lifetime
DC current [A]
resistive load
DC
voltage [V
]
2C
DC
252 1
21 F
0206
AC current [A]
resistive load
AC
voltage [V
]
2C
DC
252 1
22 F
0206
Switching current [A]
250 V
resistive load
Sw
itchin
g c
ycle
s
2C
DC
252 1
23 F
0206
cos ϕ
0.5
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
0.6
0.7
0.8
0.9
1.0
Dera
ting facto
r F
2C
DC
252 1
24 F
0206
CT-D.1x CT-D.1x
AC load (resistive) DC load (resistive)
Technical diagrams
Load limit curves
DC current [A]
resistive load
DC
vo
ltag
e [V
]
2C
DC
25
2 0
45
F0
20
7
AC current [A]
resistive load
AC
vo
ltag
e [V
]
2C
DC
25
2 0
44
F0
20
7
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 1/16
1
CT-D range
Wiring notes, Dimensional drawings
0.69“
2.76
“
0.2“2.28“
1.71“
1.77
“
17,5
70
5
58
43,4
45
2CD
C 2
52 1
31 F
0b06
0.69“17,5
3.15
“80
0.2“5
2.28“
1.71“
58
43,4
1.77
“45
2CD
C 2
52 1
30 F
0b06
CT-D devices with 1 c/o contact or 2 n/o contacts CT-D devices with 2 c/o contacts
Dimensional drawings
L(+)
N(-)
A1 Y1/B1
A2
2C
DC
25
2 1
02
F0
b0
6
Wiring notes for devices with control inputA parallel load to the control input is possible
dimensions in mm
1/17 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
1
CT-E range
Product group picture
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 1/18
1
CT-E range
Table of contents
CT-E Range
Product group picture 1/17
Table of contents 1/18
Benefits and advantages 1/19
Ordering details 1/20
Function diagrams 1/22
Connection diagrams 1/27
Connection diagrams, Technical diagrams 1/28
Technical data 1/29
Wiring notes, Dimensional drawings 1/31
Notes 1/32
1/19 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
1
CT-E range
Benefits and advantages
Characteristics – Diversity:
– 2 multifunction timers
– 56 single-function timers
– Control supply voltages:
– Dual range: 24 V AC/DC
– Single range: 110-130 V AC, 220-240 V AC
– Wide range: 24-240 V AC/DC (CT-MFE)
– Time ranges
– 5 single ranges: 0.05-1 s, 0.1-10 s, 0.3-30 s, 3-300 s,
0.3-30 min
– 8 time ranges: 0.05 s - 100 h (CT-MFE)
– Devices with 1 c/o (SPDT) contact (250 V / 4 A) or
solid-state output for high switching frequencies (thyristor
0.8 A)
– Approvals / Marks (details see page 1/4)
– A, C, R, K, E, L / a, b
1 LEDs for status indication U - green LED: V control supply voltage applied
R2: red LED: V output relay energized
2 Time range adjustment (only multifunctional devices)
3 Fine adjustment of the time delay
4 Preselection of the timing function (only multifunctional devices)
Operating controls
Direct reading scalesDirect setting of the time delay without any additional
calculation provides accurate time delay adjustment.
LEDs for status indicationAll actual operational states are displayed by front-face LEDs,
thus simplifying commissioning and troubleshooting.
Connection screws in M3 (Pozidrive 1)Easy and fast tightening and release of the connection screws
with pozidrive, pan- or crosshead screwdriver.
Solid-state outputDevices with solid-state output are the perfect solution for
high operation cycles.
4
1
2
3
Benefits
ALA1
A1
AL
1S
VC
11
0 0
00
F0
50
8
1S
VC
11
0 0
00
F0
50
0
1S
VC
11
0 0
00
F0
50
6
2C
DC
25
2 1
66
F0
00
5
1
1
2
2
3 4
4
3
Synonyms
used expression alternative expression(s) used expression alternative expression(s)
1 c/o contact SPDT voltage-related wet / non-floating
2 c/o contacts DPDT volt-free dry / floating
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 1/20
1
1S
VR
55
0 0
29
F8
10
01
SV
R 5
50
11
1 F
11
00
CT-MFE
CT-AHE
A ON-delay
B OFF-delay
CA Impulse-ON
CB Impulse-OFF
DA Flasher starting with ON
DB Flasher staring with OFF
H Pulse former
CT-E range
Ordering details
1) Functions: ON-delay, OFF-delay with auxiliary voltage, Impulse-ON, Flasher starting with ON, Flasher starting with OFF,
Pulse former
2) without auxiliary voltage, True Off-delay timer
Description
The CT-E range with its excellent price/performance ratio offers an ideal solution for serial
applications. 56 single-function devices with 5 different time ranges as well as 2 multifunction
timers with 6 functions and 8 time ranges offer the highest possible flexibility for almost every
application. For high operating cycles, contact-free CT-E timers with solid-state output are
available.
Ordering detailsTiming function
Rated con-trol supply voltage
Time ranges
Con-trol Input
Output Type Order code Price
1 pce
Weight(1 pce)kg (lb)
Multifunc-tional 1) 24-240 V AC/DC
8 (0.05 s - 100 h)
� 1 c/o CT-MFE 1SVR550029R8100 0.08 (0.18)
ON-delay
24 V AC/DC, 220-240 V AC
0.1-10 s
-
1 c/o CT-ERE
1SVR550107R1100
0.08 (0.18)
0.3-30 s 1SVR550107R4100
3-300 s 1SVR550107R2100
0.3-30 min 1SVR550107R5100
110-130 V AC
0.1-10 s
-
1SVR550100R1100
0.3-30 s 1SVR550100R4100
3-300 s 1SVR550100R2100
0.3-30 min 1SVR550100R5100
OFF-delay
24 V AC/DC
0.1-10 s
� 1 c/o CT-AHE
1SVR550118R1100
0.08 (0.18)
0.3-30 s 1SVR550118R4100
3-300 s 1SVR550118R2100
110-130 V AC
0.1-10 s 1SVR550110R1100
0.3-30 s 1SVR550110R4100
3-300 s 1SVR550110R2100
220-240 V AC
0.1-10 s 1SVR550111R1100
0.3-30 s 1SVR550111R4100
3-300 s 1SVR550111R2100
OFF-delay2)
24 V AC/DC, 220-240 V AC
0.1-10 s
- 1 c/o CT-ARE
1SVR550127R1100
0.08 (0.18)0.3-30 s 1SVR550127R4100
110-130 V AC0.1-10 s 1SVR550120R1100
0.3-30 s 1SVR550120R4100
Impulse-ON
24 V AC/DC, 220-240 V AC
0.1-10 s
- 1 c/o CT-VWE
1SVR550137R1100
0.08 (0.18)
0.3-30 s 1SVR550137R4100
3-300 s 1SVR550137R2100
110-130 V AC
0.1-10 s 1SVR550130R1100
0.3-30 s 1SVR550130R4100
3-300 s 1SVR550130R2100
Impulse-OFF2)
24 V AC/DC
0.05-1 s - 1 c/o CT-AWE
1SVR550158R3100
0.08 (0.18)110-130 V AC 1SVR550150R3100
220-240 V AC 1SVR550151R3100
� Control input with voltage-related triggering
- no triggering
1/21 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
1
CT-E range
Ordering details2
CD
C 2
51
12
5 F
00
04
2C
DC
25
1 0
59
F0
00
3
CT-AWE
CT-SDE
A ON-delay
B OFF-delay
CA Impulse-ON
CB Impulse-OFF
DA Flasher starting with ON
DB Flasher staring with OFF
H Pulse former
FA Star-delta change-over twice
ON-delayed
FC Star-delta change-over with
impulse
DE Pulse generator starting
with ON or OFF
1) without auxiliary voltage2) with fixed transition time3) solid-state output, functions and time range selection via external jumpers4) symetric ON & OFF times5) common contact6) Functions: ON-delay (AC/DC), Impuls-ON (AC only), Flasher starting with OFF (AC only)
NoticeCT-...KE are solid-state timers with thyristor output for 2-wire applications. They are connected
directly in series with the control coil of contactors or relays. Voltage should not be applied
without a load connected, because there is no current limiting in the unit.
BestellangabenTiming function
Rated con-trol supply-voltage
Time ranges
Con-trol Input
Output Type Order code Price
1 pce
Weight(1 pce)
kg (lb)
Impulse-OFF
24 V AC/DC
0.1-10 s
� 1 c/o CT-AWE
1SVR550148R1100
0.08 (0.18)
0.3-30 s 1SVR550148R4100
3-300 s 1SVR550148R2100
110-130 V AC
0.1-10 s 1SVR550140R1100
0.3-30 s 1SVR550140R4100
3-300 s 1SVR550140R2100
220-240 V AC
0.1-10 s 1SVR550141R1100
0.3-30 s 1SVR550141R4100
3-300 s 1SVR550141R2100
Flasher staring with OFF
24 V AC/DC, 220-240 V AC 0.1-10 s - 1 c/o CT-EBE 4)
1SVR550167R11000.08 (0.18)
110-130 V AC 1SVR550160R1100
Star-delta change-over twice ON-delayed
24 V AC/DC, 220-240 V AC
0.1-10 s
- 1 c/oCT-YDE 1) 2)
1SVR550207R1100
0.08 (0.18)
0.3-30 s 1SVR550207R4100
3-300 s 1SVR550207R2100
110-130 V AC
0.1-10 s 1SVR550200R1100
0.3-30 s 1SVR550200R4100
3-300 s 1SVR550200R2100
Star-delta change-over with impuls
24 V AC/DC, 220-240 V AC
0.3-30 s -1 n/o + 1 n/c
CT-SDE 2) 5)
1SVR550217R4100
0.08 (0.18)110-130 V AC 1SVR550210R4100
380-415 V AC 1SVR550212R4100
Multifunc-tional 8) 24-240V AC/DC
0.1-10 s, 3-300 s
-
solide-state
CT-MKE 3) 6) 1SVR550019R0000 0.08 (0.18)
ON-delay 24-240 V AC/DC
0.1-10 s
- CT-EKE
1SVR550509R1000
0.08 (0.18)0.3-30 s 1SVR550509R4000
3-300 s 1SVR550509R2000
OFF-delay 24-240 V AC
0.1-10 s
- CT-AKE
1SVR550519R1000
0.08 (0.18)0.3-30 s 1SVR550519R4000
3-300 s 1SVR550519R2000
� Control input with voltage-related triggering
- no triggering
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 1/22
1
CT-E range
Function diagrams
A ON-delay (Delay on make) CT-ERE, CT-MFE
B OFF-delay, with auxiliary voltage (Delay on break) CT-AHE, CT-MFE
t = adjusted time delay
t = adjusted time delay
Minimum control pulse length: 20 ms
< t
A1-A2/B1
15-1815-16
t 2CD
C 2
52 1
30 F
0205
green LED
red LED
A1-A2
A1-Y1
15-1615-18
t
2CD
C 2
52 1
32 F
0205
green LED
red LED
Applying control supply voltage starts timing. When the
selected time delay is complete, the output relay energizes.
If control supply voltage is interrupted, the output relay
de-energizes and the time delay is reset. Interrupting control
supply voltage before the time delay is complete, resets the
time delay. The output relay does not energize.
This function requires continuous control supply voltage for
timing.
Timing is controlled by control input A1-Y1. If the control input
is closed, the output relay energizes. If control input A1-Y1 is
opened, the selected time delay starts. When the time delay
is complete, the output relay de-energizes. If control input A1-
Y1 is closed before the time delay is complete, the time delay
is reset. Timing starts again when the control input re-opens.
RemarksLegendG Control supply voltage not applied / Output contact open
B Control supply voltage applied / Output contact closed
A1-Y1/B1: Control input with voltage-related triggering
Terminal designations on the device and in the diagramsThe c/o contact is always designated 15-16/18.
The n/o contacts are designated with 15-16 and 15-18.
Control supply voltage is always applied to terminals
A1-A2/B1.
Function of the red LEDThe red LED R glows as soon as the output relay energizes
and turns off when the output relay de-energizes.
1/23 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
1CA Impulse-ON (Interval) CT-VWE, CT-MFE
B OFF-delay, without auxiliary voltage (true delay on break) CT-ARE
t = adjusted time delay
A1-A2/B1
15-1815-16
t
2CD
C 2
52 1
33 F
0205
green LED
This function requires continuous control supply voltage
for timing. Timing is controlled by control input A1-Y1. If
the control input is opened, the output relay energizes and
timing begins. When the selected time delay is complete,
the output relay de-energizes. Interrupting control supply
voltage or closing control input A1-Y1, before the time delay
is complete, de-energizes the output relay and resets the time
delay.
The Impulse-OFF function without auxiliary voltage does not
require continuous control supply voltage for timing.
If control supply voltage is interrupted, the output relay
energizes and the OFF time starts. When timing is complete,
the output relay de-energizes. If control supply voltage is
re-applied before the time delay is complete, the time delay is
reset and the output relay de-energizes.
Control supply voltage must be applied for the minimum
energizing time (200 ms), for proper operation.
t = adjusted pulse time
t = adjusted pulse time
A1-A2
A1-Y1
15-1615-18
t
2CD
C 2
52 1
37 F
0205
green LED
red LED
A1-A2
15-1615-18
t 2CD
C 2
52 1
38 F
0205
green LED
red LED
The output relay energizes immediately when control sup-
ply voltage is applied and de-energizes after the selected
time delay is complete. If control supply voltage is inter-
rupted before the time delay is complete, the output relay
de-energizes and the time delay is reset.
Control input A1-Y1 has to be jumpered, when this timing
function is selected.
The OFF-delay function without auxiliary voltage does not
require continuous control supply voltage for timing.
Applying control supply voltage, energizes the output relay.
If control supply voltage is interrupted, the OFF-delay starts.
When timing is complete, the output relay de-energizes. If
control supply voltage is re-applied before the time delay is
complete, the time delay is reset and the output relay remains
energized.
Control supply voltage must be applied for the minimum
energizing time (200 ms), for proper operation.
CB Impulse-OFF, with auxiliary voltage (Trailing edge interval) CT-AWE
CB Impulse-OFF, without auxiliary voltage (True trailing edge interval) CT-AWE
t = adjusted pulse time
t = adjusted pulse time
A1-A2/B1
15-1815-16
< tt 2CD
C 2
52 1
34 F
0205
green LED
red LED
A1-A2
15-1815-16
< tt
A1-Y1
2CD
C 2
52 1
35 F
0205
green LED
red LED
CT-E range
Function diagrams
CT-VWE:
CT-MFE:
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 1/24
1DA Flasher starting with ON (Recycling equal times, ON first) CT-MFE
t = adjusted flashing time
DB Flasher starting with OFF (Recycling equal times, OFF first) CT-EBE, CT-MFE
t = adjusted flashing time
H Pulse former (Single shot) CT-MFE
t = adjusted pulse time
A1-A2
A1-Y1
15-1615-18
tt
2CD
C 2
52 1
36 F
0205
green LED
red LED
Closing the control input A1-Y1, with control supply voltage
applied, energizes the output relay for the selected ON time.
Operating the control input during timing has no effect. When
the ON time is complete, the output relay de-energizes.
Timing can be restarted by re-closing control input A1-Y1. If
control supply voltage is interrupted during timing, the output
relay de-energizes and the ON time is reset.
Applying control supply voltage starts timing with symmetrical
ON & OFF times. The cycle starts with an ON time first.
If control supply voltage is interrupted, the output relay
de-energizes and the time delay is reset.
Control input A1-Y1 has to be open, when this timing function
is selected.
Applying control supply voltage starts timing with symmetrical
ON & OFF times. The cycle starts with an OFF time first.
If control supply voltage is interrupted, the output relay
de-energizes and the time delay is reset.
Control input A1-Y1 has to be jumpered, when this timing
function is selected.
A1-A2
A1-Y1
15-16 15-18
t t
2CD
C 2
52 0
26 F
0209
green LED
red LED
A1-A2/B1
15-1615-18
t t 2CD
C 2
52 1
40 F
0205
green LED
red LED
15-1615-1815-1615-18
t t
A1-A2
A1-Y1
2CD
C 2
52 0
23 F
0209
green LED
red LED
t = adjusted flashing time
CT-E range
Function diagrams
CT-EBE:
CT-MFE:
1/25 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
1
-K1-K3
L1
-F1
1
2
95
96
97
98
L2
3
4
L3
5
6
1
2
3
4
5
6
1
2
3
4
5
6-K2
-F2
1
2
3
4
5
6
1
3
5
2
4
6
M
3 ~
W2V2U2
W1V1U1
-M1
K1
K3
K3
Y � N
K2
K2
K2
L1
N
F3
F2
95
96
21
22
21
22
21
22
A1
A2
A1
A2
A1
A2
A1
A2
21
22
16
15
13
14
43
44
13
14
13
14
S10
IS2
K1
K1T
K1TK1
K1
2C
DC
25
3 0
02
F0
01
3
2C
DC
25
3 0
09
F0
01
2
K1T
K1T K1T
K3
K3
Y � N
K2
K2
K2
L1
N
F3
F2
95
96
21
22
22
21
A1B1
A2
A1
A2
A1
A2
A1
A2
22
21
13
14
15
16
15
18
13
14
53
54
53
54
S10
IS2
K1
K1
K1
2C
DC
25
3 0
01
F0
01
3
FC Star-delta change-over CT-SDE
FA Star-delta change-over CT-YDE
Power circuit diagram
Control circuit diagram
Control circuit diagram
A1-A2/B1
15-16 15-18
t1 t2
2CD
C 2
52 1
33 F
0206
Star contactor
Delta contactor
green LED
red LED
t1 = adjustable starting timet2 = fixed transition time of 50 ms
A1-A2/B1
15-16 15-18
t1 t2
2CD
C 2
52 1
34 F
0206
Star contactor
Delta contactor
green LED
red LED
t1 = adjustable starting timet2 = fixed transition time of 30 ms
Applying control supply voltage energizes the star contactor
(K1) and the line contactor (K2) and begins the set starting
time. When the starting time is complete, contact 15-16
de-energizes the star contactor (K1) Now, the fix transition
time starts. When the transition time is complete, contact
15-16 energizes the delta contactor (K3).
Applying control supply voltage energizes the star contactor
(K1) and the line contactor (K2) and begins the set starting
time. When the starting time is complete, contact 15-16
de-energizes the star contactor (K1). Now, the fix transition
time starts. When the transition time is complete, contact
15-18 energizes the delta contactor (K3).
CT-E range
Function diagrams
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 1/26
1
2C
DC
25
2 0
01
F0
21
3
A1-A2
t < t
Thyristor A1-A2
2CD
C 2
52 1
46 F
0205
red LED
A1-A2
t < t
Thyristor A1-A2
2CD
C 2
52 1
47 F
0205
red LED
A1-A2
Thyristor A1-A2
t t
2CD
C 2
52 1
48 F
0205
red LED
A1-A2
t t
Thyristor A1-A2
2CD
C 2
52 1
49 F
0205
red LED
t = adjusted time delay
t = adjusted pulse time
t = adjusted flashing time
t = adjusted flashing time
A ON-delay (Delay on make) CT-EKE
t = adjusted time delay
B OFF-delay, with auxiliary voltage (Delay on break) CT-AKE
t = adjusted time delay
Multifunction timer CT-MKEFunctions and time ranges are programmed by simply plugging in external wire jumpers.
Notice:CT-...KE are solid-state timers with thyristor output for 2-wire applications. They are connected directly in series with the control coil
of contactors or relays. Voltage should not be applied without a load connected, because there is no current limiting in the unit.
A ON-delay (Delay on Make)Without external connection. Timing begins when control supply voltage
is applied to terminal A1 and the load connected in series with A2. When
the selected time delay is complete, the load energizes. If control supply
voltage is interrupted, the load de-energizes and the time delay is reset.
Interrupting supply voltage before the time delay is complete, resets the
time delay. The load does not energize.
CA Impulse-ON (Interval)External connection X1-X4 required. The load energizes and timing
starts when control supply voltage is applied to terminal A1 and the load
connected in series with A2. When the selected time delay is complete,
the load de-energizes. Interrupting control supply voltage before the time
delay is complete, de-energizes the load and resets the time delay.
DA Flasher, starting with ONExternal connection X1-X4 and X2-X4 required. When control supply
voltage is applied to terminal A1 and the load connected in series with
A2, the load energizes and de-energizes with the selected ON & OFF
times. The ON & OFF times are equal. The cycle starts with an ON time
first (load energized). If control supply voltage is interrupted, the load
de-energizes and the time delay is reset.
DB Flasher, starting with OFFExternal connection X2-X4 required. When control supply voltage is
applied to terminal A1 and the load connected in series with A2, the
load energizes and de-energizes with the selected ON & OFF times.
The ON & OFF times are equal. The cycle starts with an OFF time first
(load de-energized). If control supply voltage is interrupted, the load
de-energizes and the time delay is reset.
A1-AL
t < t
Thyristor A1-AL
2CD
C 2
52 1
50 F
0205
green LED
A1-AL
t
Y2-A2
Thyristor A1-AL
green LED
Timing begins when control supply voltage is applied to
terminal A1 and the load connected in series with AL. When
the selected time delay is complete, the load energizes. The
green LED glows as long as the load is energized.
If control supply voltage is interrupted, the load de-energizes
and the time delay is reset. Interrupting control supply voltage
before the time delay is complete, resets the time delay. The
load does not energize.
The OFF-delay function with auxiliary voltage requires
continuous control supply voltage at terminal A1, and the
load connected in series with AL, for timing.
Timing is controlled by control input Y2-A2. When the
control input is closed, the load energizes. If the control
input is opened, the selected time delay starts (minimum
control pulse length is 20 ms). The green LED glows as long
as the load is energized. When the selected time delay is
complete, the load de-energizes. If control input Y2-A2 is
closed before the time delay is complete, the time delay is
reset and the load remains energized. Timing starts again
when the control input is re-opened. Interrupting control
supply voltage resets the time delay and de-energizes the
load.
CT-E range
Function diagrams
Programming the time rangesX3-X4 jumpered: 0.1-10 s
X3-X4 open: 3-300 s
1/27 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
12C
DC
252
152
F00
05A1
A1
A2
15
15
16
16 18 A2
18
Y1
2CD
C 2
52 1
53 F
0005
A1 B1
16 18 A2
A2 16 18
A1 15
15
B1
2CD
C 2
52 1
54 F
0005A1
A1
A2 16 18
15
15 Y1
16 18 A2
2CD
C 2
52 1
55 F
0005
A1
A2 16 18
B1 15
15A1 B1
1816 A2
CT-MFE A CT-ERE B CT-AREB CT-AHE 1)
15 A1
A1
A2 B1 16 18
15
B1
18 16 A2
2CD
C 2
52 1
56 F
0b05 15 A1
A1
A2 16 18
15
18 16 A2
2CD
C 2
52 1
57 F
0b05 15 Y1 A1
A1
A2 16 18
15
18 16 A2 2C
DC
252
158
F0b
05
CA CT-VWE CB CT-AWE CB CT-AWE 1)
2CD
C 2
52 1
59 F
000515 B1A1
A1 B1 15
1816
A2 16 18
A2
DB CT-EBE
FA CT-YDE FC CT-SDE FC CT-SDE
2CD
C 2
52 1
60 F
000515 B1A1
A1
A2 B1 16 18
15
1816 A2
2CD
C 2
52 1
61 F
000515 B1A1
A1
A2 B1 16 18
15
1816 A2
2CD
C 2
52 1
62 F
000515A1
A1
A2 16 18
15
1816 A2
2CD
C 2
52 1
65 F
0005X2
A1
A2U
X1A1
X4X3 A2
CT-MKE
Device without aux. voltage Device with aux. voltage
Device: 1SVR 550 217 R4100 Devices: 1SVR 550 210 R4100,
1SVR 550 212 R4100
CT-E range
Connection diagrams
A1-A2 Supply: 24-240 V AC/DC
A1-Y1 Control input
15-16/18 c/o contact
A1-A2 Supply: 220-240 V AC
or 110-130 V AC
A1-B1 Supply: 24 V AC/DC
15-16/18 c/o contact
A1-A2 Supply: 220-240 V AC
A1-B1 Supply: 24 V AC/DC
15-16 n/c contact
15-18 n/o contact
with common contact
A1-A2 Supply: 110-130 V AC
or 380-415 V AC
15-16 n/c contact
15-18 n/o contact
with common contact
A1-A2 Supply: 220-240 V AC
or 110-130 V AC
A1-B1 Supply: 24 V AC/DC
15-16/18 c/o contact
A1-A2 Supply: 220-240 V AC
or 110-130 V AC
A1-B1 Supply: 24 V AC/DC
15-16/18 c/o contact
A1-A2 Supply: 220-240 V AC
or 110-130 V AC
A1-B1 Supply: 24 V AC/DC
15-16/18 c/o contact
A1-A2 Supply: 220-240 V AC or
110-130 V AC
A1-B1 Supply: 24 V AC/DC
15-16/18 c/o contact
A1-A2 Supply: 24-240 V AC/DC
A1-A2 Thyristor
X1-X4 Timing function adjustment
X2-X4 Timing function adjustment
X3-X4 Time range adjustment
(Details see function diagrams)
A1-A2 Supply: 24 V AC/DC or 110-240 V AC or 220-240 V AC
A1-Y1 Control input
15-16/18 c/o contact
A1-A2 Supply: 24 V AC/DC or 110-240 V AC or 220-240 V AC
A1-Y1 Control input
15-16/18 c/o contact
A1(+)-A2(-) Supply: 24 V AC/DC or 110-240 V AC or 220-240 V AC
15-16/18 c/o contact
1) “„Wiring notes, Dimensional drawings“ see page 1/31.
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 1/28
12C
DC
252
166
F00
05ALA1
A1
AL
2CD
C 2
52 1
67 F
0005ALA1
A1Y2
A2AL
A2Y2
A CT-EKE B CT-AKE
220 V 50 Hz AC1
360 cycles/h
300
200
100 80 60 50 40 30
20
10 1 2 4 6 10
I A
V
U
2CD
C 2
52 1
93 F
0205
0,1 0,2 0,5
cos ϕ
F
2CD
C 2
52 1
92 F
0205
0,5
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1,0
0,6
0,7
0,8
0,9
1,0
300
200
100 80 60 50 40 30
20
10 1 2 4 6 10
I A
V
U
2CD
C 2
52 1
94 F
0205
0,1 0,2 0,5
4 3 2 1 105
2
3 4
N
I A
5
8 9
106
5 6 7 8
2CD
C 2
52 0
34 F
0208
AC load (resistive) DC load (resistive)
Technical diagrams
Load limit curves
Derating factor F for inductive AC load Contact lifetime
CT-E range
Connection diagrams, Technical diagrams
A1-AL Supply: 24-240
V AC/DC
A1-AL Thyristor
A1-AL Supply: 24-240 V AC
A1-AL Thyristor
Y2-A2 Control input
1/29 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
1
CT-E range
Technical data
Technical dataData at T
a = 25 °C and rated values, unless otherwise indicated
CT-E (relays) CT-E (solid-state)
Input circuit - Supply circuitRated control supply voltage U
sA1-A2, A1-AL 24-240 V AC/DC
A1-A2, A1-AL 24-240 V AC
A1-A2 110-130 V AC -
A1-A2 220-240 V AC -
A1-A2 380-415 V AC -
A1-B1 24 V AC/DC -
Rated control supply voltage Us tolerance -15...+10 %
Rated frequency AC/DC versions DC or 50/60 Hz
AC versions 50/60 Hz
Typical current / power consumption 24-240 V AC/DC, 24-240 V AC approx. 1.0-2.0 VA/W
110-130 V AC, 220-240 V AC approx. 2.0 VA -
380-415 V AC approx. 3.0 VA -
24 V AC/DC approx. 1.0 VA/W -
Minimum energizing time CT-ARE, CT-AWE w/o aux. voltage 200 ms -
Current consumption while timing - ≤ 2 mA (24-60 V AC/DC)≤ 8 mA (60-240 V AC/DC)(CT-AKE only AC)
Input circuit - Control circuitKind of triggering voltage-related triggering -
Control input, Control function A1-Y1 start timing external -
Parallel load / polarized no / yes 1) -
Minimum control pulse length 20 ms -
Control voltage potential see rated control supply voltage -
Timing circuitTime ranges 1 of 5 time ranges per single-function device 0.05-1 s / 0.1-10 s / 0.3-30 s / 3-300 s / 0.3-30 min
8 time ranges 0.05 s - 100 h (CT-MFE) 1.) 0.05-1 s 3.) 5-100 s 5.) 0.5-10 min 7.) 0.5-10 h
2.) 0.5-10 s 4.) 50-1000 s 6.) 5-100 min 8.) 5-100 h
-
2 time ranges 0.1-300 s (CT-MKE) - 1.) 0.1-10 s 2.) 3-300 s
Recovery time <50 msCT-ARE: <200 msCT-AWE, CT-SDE: <400 msCT-YDE: <500 ms
CT-EKE: <50 msCT-MKE: <100 msCT-AKE: <300 ms
Accuracy within the rated control supply voltage tolerance �t < 0.5 % / VAccuracy within the temperature range �t < 0.1 % / °C
CT-MFE: �t <0.06 % / °C -
Repeat accuracy (constant parameters) �t < 1 %Star-delta transition time CT-YDE / CT-SDE 50 ms / 30 ms -
Output circuitKind of output 15-16/18 Relay, 1 c/o contact -
CT-SDE: 15-16, 15-18 1 n/c, 1 n/o contact with common contact
A1-A2. A1-AL - Thyristor
Contact material AgCdO -
Rated operational voltage Ue
IEC/EN 60947-1 250 V
Maximum switching voltage 250 V AC, 250 V DC
Rated operational current Ie
(IEC/EN 60947-5-1)AC-12 (resistive) at 230 V 4 A -
AC-15 (inductive) at 230 V 3 A -
DC-12 (resistive) at 24 V 4 A -
DC-13 (inductive) at 24 V 2 A -
1) CT-MFE: yes / no
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 1/30
1CT-E (relays) CT-E (solid-state)
AC rating (UL 508) Utilization category (Control Circuit Rating Code) B 300 -
max. rated operational voltage 300 V AC -
Maximum continuous thermal current at B300 5 A -
max. making/breaking apparent power at B300 3600 VA / 360 VA -
Mechanical lifetime 30 x 106 switching cycles -
Electrical lifetime at AC-12, 230 V, 4 A 0.1 x 106 switching cycles -
Max. fuse rating to achieve short-circuit protection (IEC/EN 60947-5-1)
n/c contact 10 A fast-acting, CT-ARE: 5 A -
n/o contact 10 A fast-acting, CT-ARE: 5 A -
Minimum load current - CT-MKE: 20 mACT-EKE, CT-AKE: 10 mA
Maximum load current - CT-MKE: 0.8 A at Ta = 20 °C
CT-EKE, CT-AKE: 0.7 A
Load current reduction / Derating - 10 mA/°C
Maximum surge current - CT-MKE: ≤ 20 A for t ≤ 20 msCT-EKE, CT-AKE: ≤ 15 A
Voltage drop in connected state - ≤ 3 V
Cable length between solid-state timer and connected load at 50 Hz and a cable capacity of 100 pF/m :
at 24 V AC - 220 m / 22 nF
at 42 V AC - 100 m / 10 nF
at 60 V AC - 65 m / 6.5 nF
at 110 V AC - 50 m / 5 nF
at 240 V AC - 22 m / 2.2 nF
General dataDuty time 100%
Dimensions (W x H x D) 22.5 x 78 x 78.5 mm (0.886 x 3.07 x 3.09 in)
Weight approx. 80 g (0.176 lb)
Mounting DIN rail (IEC/EN 60715)
Mounting position any
Minimum distance to other units horizontal / vertical no / no
Degree of protection housing / terminals IP50 / IP20
Electrical connectionWire size fine-strand with wire end ferrule 2 x 0.75-1.5 mm2 (2 x 18-16 AWG)
fine-strand without wire end ferrule 2 x 1-1.5 mm2 (2 x 18-16 AWG)
rigid 2 x 0.75-1.5 mm2 (2 x 18-16 AWG)
Stripping length 10 mm (0.39 in)
Tightening torque 0.6-0.8 Nm (5.31-7.08 lb.in)
Environmental dataAmbient temperature ranges operation / storage -20...+60 °C / -40...+85 °C
Damp heat IEC/EN 60068-2-30 24 h cycle, 55 °C, 93 % rel., 96 h
Operational reliability IEC/EN 60068-2-6 6 g
Mechanical resistance IEC/EN 60068-2-6 10 g
Isolation dataRated impulse withstand voltage U
imp
between all isolated circuitsIEC/EN 60664-1 type test: 4 kV; 1.2/50 μs -
Pollution category IEC/EN 60664-1 3
Overvoltage category IEC/EN 60664-1 III
Power-frequency withstand voltage (test voltage) between all isolated circuits
routine test: 2.5 kV; 50 Hz; 1 stype test: 2.5 kV; 50 Hz; 60 s
-
Basic insulation (IEC/EN 61140) input circuit / output circuit 300 V -
Rated insulation voltage Ui
input circuit / output circuit 300 V (supply up to 240 V) -
500 V (supply up to 440 V) -
Test voltage between all isolated circuits routine test 2.5 kV, 50 Hz, 1 s -
StandardsProduct standard IEC 61812-1, EN 61812-1 + A11, DIN VDE 0435 Teil 2021
Low Voltage Directive 2006/95/EC
EMC Directive 2004/108/EC
Electromagnetic compatibilityInterference immunity to IEC/EN 61000-6-2
electrostatic discharge IEC/EN 61000-4-2 Level 3 (6 kV / 8 kV)
radiated, radio-frequency electromagnetic field
IEC/EN 61000-4-3 Level 3 (10 V/m)
electrical fast transient / burst IEC/EN 61000-4-4 Level 3 (2 kV / 5 kHz)
surge IEC/EN 61000-4-5 Level 4 (2 kV L-L)
conducted disturbances, induced by radio-frequency fields
IEC/EN 61000-4-6 Level 3 (10 V)
Interference emission IEC/EN 61000-6-4
„Approvals and marks“ see page 1/4.
CT-E range
Technical data
1/31 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
1
CT-E range
Wiring notes, Dimensional drawings
3.48“
3.19“
3.09“
.886“
3.07
“
88,5
81
78,5
78
22,5
2CD
C 2
52 1
89 F
0b05
A1 Y1
A2
I
I
I 2C
DC
252
200
F0b
05
U
A1
A2
Y1
2CD
C 2
52 1
99 F
0b05
U
Dimensional drawing Dimensions in mm
Wiring notesfor single-function devices with control contact (CT-AHE, CT-AWE with auxiliary voltage)
I
I A1
A2
Y1
I
2CD
C 2
52 1
98 F
0b05
U A1 Y1
A2
2CD
C 2
52 2
01 F
0b05
U
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 1/32
1
CT-E range
Notes
1/33 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
1
CT-S range
Product group picture
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 1/34
1
CT-S range
Table of contents
CT-S Range
Product group picture 1/33
Table of contents 1/34
Benefits and advantages 1/35
Ordering details - multifunctional 1/37
Ordering details - singlefunctional 1/38
Ordering details - Accessories 1/39
Ordering details - Accessories 1/40
Function diagrams 1/41
Connection diagrams 1/49
Technical data 1/52
Technical diagrams 1/55
Wiring notes, Dimensional drawings 1/56
1/35 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
1
CT-S range
Benefits and advantages
Characteristics – Diversity:
– 8 multifunction timers
– 13 single-function timers
– Control supply voltages:
– Multi range: 24-48 V DC, 24-240 V AC
– Wide range: 24-240 V AC/DC
– Single range: 380-440 V AC
– Innovative connection technology
– Double-chamber cage connection terminals
– Easy Connect Technology
– Devices with:
– 1 or 2 c/o (SPDT) contacts
– 2nd c/o contact can be selected as instantaneous contact 1)
– Remote potentiometer connection 1)
– Control input with volt-free or voltage-related triggering e.g. to start timing, pause timing
– Extended operating temperature range down to -40 °C 1)
– Sealable transparent cover for protection against unauthorized changes of time values
– Integrated marker label
– Approvals / Marks (partly pending, details see page 1/4)
– A, C, , E, K, L / a, b1) selected devices
1 2nd contact as an instantaneous contact
2 Preselection of the time range
3 Indication of operational states U/T: V control supply voltage applied / W timing
R: V Output relay energized
4 Fine adjustment of time delay
4 Preselection of timing function
Marker label
Operating controls
4
1
2
3
5
6
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 1/36
1LEDs for status indicationAll actual operational states are displayed by front-face LEDs,
thus simplifying commissioning and troubleshooting.
Integrated marker labelIntegrated marker labels allow the product to be marked
quickly and simply. No additional marker labels are required.
Sealable transparent coverProtection against unauthorized changes of time and
threshold values. Available as an accessory.
Snap-On housingTool-free DIN rail installation and deinstallation of the
electronic timer.
CT-S range
Benefits and advantages
Easy Connect TechnologyTool-free wiring and excellent vibration resistance. Push-in
terminals provide connection of wires up to 2 x 0.5 - 1.5 mm²
(2 x 20 -16 AWG), rigid or fine-strand with or without wire
end ferrules. The extended type designators for products with
push-in terminals are indicated by a P following the extended
type designator e.g. CT-xxS.xxP.
Double-chamber cage connection terminalsDouble-chamber cage connection terminals provide
connection of wires up to 2 x 0.5-2.5 mm² (2 x 20-14 AWG)
rigid or fine-strand, with or without wire end ferrules. Potential
distribution does not require additional terminals. The
extended type designators for products with double-chamber
cage connection terminals are indicated by a S following the
extended type designator e.g. CT-xxS.xxS.
Time range preselection and fine adjustmentDirect assignment of the preselected time range to the fine
adjustment potentiometer scale by multicolor scales.
Higher utility classThe Easy Connect Technology provides excellent vibra-
tion resistance with gas tight push-in terminals – the right
solution for harsh environment. Selected products of the
electronic timers and measuring and monitoring relays comply
to the latest rail standards NF F 16-101/102, EN 45545, EN
50155 and more standards which are relevant for railway
applications. Find more inforamtion in the rail brochure
2CDC110084B0201.
1
2
3
4
6
5
7
8
4
2C
DC
25
3 0
35
F0
01
1
2C
DC
25
3 0
26
F0
01
12
CD
C 2
53
02
5 F
00
11
2C
DC
25
2 0
06
F0
01
2
2C
DC
25
5 0
06
S0
01
1
2C
DC
25
3 0
07
F0
01
2
2C
DC
25
3 0
13
F0
01
3
2
1 3 7
6 8
5
1/37 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
1
CT-S range
Ordering details - multifunctional2
CD
C 2
51
02
4 V
00
11
CT-MVS.21P
2C
DC
25
1 0
23
V0
01
1
CT-MBS.22P
DescriptionThe highly sophisticated CT-S range in ABB’s new S-range housing offers two different
types of connection terminals and is ideally suited for universal use. Two different connection
technologies are available:
– Double-chamber cage connection terminals
– Easy Connect Technology
Accessories:The CT-S range offers the possibility of using accessories such as a remote potentiometer to
adjust the time delay or a sealable, transparent cover to protect against unauthorized changes.
of time and threshold values.
Ordering details
A(+) ON-delay (accumulative)
B OFF-delay without aux. voltage
CA Impulse-ON
CB Impulse-OFF
AB Symmetrical ON-delay and
OFF-delay
DA Flasher starting with ON
DB Flasher staring with OFF
DE Pulse generator starting
FC Star-delta change-over with
impulse
H Pulse former
G ON/OFF-function
FA Star-delta change-over twice
ON-delayed
with ON or OFF
ED Pulse generator starting with
ON or OFF
EC Single-pulse generator
CE Impulse-ON/OFF
DA Flasher starting with ON
DB Flasher starting with OFF
AC fixed impulse with adjustable
time delay
BC Adjustable impulse with fixed
time delay
Timing function
Rated control supply volt-age
Time ranges
Control input
Output Type Order code Price
1 pce
Weight(1 pce)
kg (lb)
Multifunc-tional 5)
24- 240 V AC/DC
10 (0.05 s - 300 h)
� 2 c/o
CT-MVS.21S 1) 2) 3) 1SVR730020R0200
0.148 (0.326)
CT-MVS.21P 1) 2) 3) 1SVR740020R0200
0.136 (0.30)
24-48 V DC, 24-240 V AC
CT-MVS.22S 1SVR730020R33000.142 (0.313)
CT-MVS.22P 1SVR740020R33000.131 (0.289)
380-440 V AC
CT-MVS.23S 1SVR730021R23000.144 (0.317)
CT-MVS.23P 1SVR740021R23000.133 (0.293)
Multifunc-tional 6)
24-48 V DC, 24-240 V AC
10 (0.05 s - 300 h)
� 1 c/o
CT-MVS.12S 1SVR730020R31000.107 (0.236)
CT-MVS.12P 1SVR740020R31000.102 (0.225)
Multifunc-tional 7)
24-48 V DC, 24-240 V AC
2×10 (0.05 s - 300 h)
� 2 c/o
CT- MXS.22S 4) 1SVR730030R33000.142 (0.313)
CT-MXS.22P 4) 1SVR740030R33000.131 (0.289)
Multifunc-tional 8)
24- 240 V AC/DC10 (0.05 s - 300 h)
� / � 2 c/o
CT-MFS.21S 1) 2) 3) 1SVR730010R0200
0.145 (0.32)
CT-MFS.21P 1) 2) 3) 1SVR740010R0200
0.133 (0.293)
24-48 V DC, 24-240 V AC
10 (0.05 s - 300 h)
� / � 2 c/o
CT-MBS.22S 2) 3) 1SVR730010R32000.14 (0.309)
CT-MBS.22P 2) 3) 1SVR740010R32000.129 (0.284)
Multifunc-tional 9)
24-48 V DC, 24-240 V AC
10 (0.05 s - 300 h)
- 2 c/o
CT-WBS.22S 1SVR730040R33000.123 (0.271)
CT-WBS.22P 1SVR740040R33000.115 (0.254)
1) Extended temperature range -40 °C2) Remote potentiometer connection3) 2nd c/o contact selectable as instantaneous contact4) 2 remote potentiometer connections5) Functions: ON-delay, OFF-delay with auxiliary voltage, Impulse-ON, Impulse-OFF with auxiliary voltage, Symmetrical ON- and
OFF-delay, Flasher starting with ON or OFF, Star-delta change-over with impulse, Pulse former, Accumulative ON-delay, ON/
OFF-function6) Functions: ON-delay, OFF-delay with auxiliary voltage, Impulse-ON, Impulse-OFF with auxiliary voltage, Symmetrical ON- and
OFF-delay, Flasher starting with ON or OFF, Pulse former, Accumulative ON-delay, ON/OFF-function7) Functions: Select function via DIP switches behind the marker label on the front of the unit, asymmetrical ON- and OFF-delay,
Impulse-ON/OFF, Pulse generator starting with ON or OFF, Single pulse generator, ON/OFF-function8) Functions: ON-delay, OFF-delay with auxiliary voltage, Impulse-ON, Impulse-OFF with auxiliary voltage, Symmetrical ON- and
OFF-delay, Flasher starting with ON, Flasher starting with OFF, Star-delta change-over with impulse, Pulse former, ON/OFF-
function9) Functions: Flasher starting with ON, Flasher starting with OFF, Impulse-ON, ON-delay, fixed impulse with adjustable time delay,
Adjustable impulse with fixed time delay, ON/OFF-function
� Control input with voltage-related triggering
� Control input with volt-free triggering
� / � two control input with volt-free triggering
- no triggering
S: screw connection
P: push-in / easy connect
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 1/38
1
CT-S range
Ordering details - singlefunctional
Timing function
Rated con-trol supply voltage
Time ranges
Con-trol input
Output Type Order code Price
1 pce
Weight(1 pce)
kg (lb)
ON-delay
24-240 V AC/DC
10 (0.05 s - 300 h)
- 2 c/o
CT-ERS.21S1) 1SVR730100R03000.13 (0.287)
CT-ERS.21P1) 1SVR740100R03000.121 (0.267)
24-48 V DC, 24-240 V AC
CT-ERS.22S 1SVR730100R33000.121 (0.267)
CT-ERS.22P 1SVR740100R33000.113 (0.249)
24-48 V DC, 24-240 V AC
- 1 c/o
CT-ERS.12S 1SVR730100R31000.106 (0.234)
CT-ERS.12P 1SVR740100R31000.101 (0.222)
OFF-delay
24-240 V AC/DC
10 (0.05 s - 300 h)
� 2 c/o
CT-APS.21S1) 1SVR730180R03000.146 (0.322)
CT-APS.21P1) 1SVR740180R03000.125 (0.276)
24-48 V DC,24-240 V AC
CT-APS.22S 1SVR730180R33000.138 (0.304)
CT-APS.22P 1SVR740180R33000.127 (0.28)
� 1 c/o
CT-APS.12S 1SVR730180R31000.109 (0.24)
CT-APS.12P 1SVR740180R31000.103 (0.227)
24-48 V DC,24-240 V AC
10 (0.05 s - 300 h)
� 2 c/o
CT-AHS.22S 1SVR730110R33000.136 (0.30)
CT-AHS.22P 1SVR740110R33000.125 (0.276)
OFF-delay5) 24-240 V AC/DC
7 (0.05 s - 10 min)
- 1 c/o
CT-ARS.11S 1SVR730120R31000.106 (0.234)
CT-ARS.11P 1SVR740120R31000.10 (0.22)
- 2 c/o
CT-ARS.21S 1SVR730120R33000.124 (0.273)
CT-ARS.21P 1SVR740120R33000.115 (0.254)
Star-delta change-over6)
24-48 V DC, 24-240 V AC
7 (0.05 s - 10 min)
- 2 n/o
CT-SDS.22S 1SVR730210R33000.114 (0.251)
CT-SDS.22P 1SVR740210R33000.108 (0.238)
380-440 V AC
CT-SDS.23S 1SVR730211R23000.118 (0.26)
CT-SDS.23P 1SVR740211R23000.112 (0.247)
2C
DC
25
1 0
30
V0
01
1
CT-ERS.21P
2C
DC
25
1 0
33
V0
01
1
CT-AHS.22P
2C
DC
25
1 0
40
V0
01
1
CT-SDS.23P
1) Extended temperature range -40 °C2) Remote potentiometer connection3) 2nd c/o contact selectable as instantaneous contact4) 2 remote potentiometer connections5) Without auxiliary voltage6) 50 ms transition time
A(+) ON-delay (accumulative)
B OFF-delay without aux.voltage
CA Impulse-ON
DA Flasher starting with ON
DB Flasher staring with OFF
CE Impulse-ON/OFF
DA Flasher starting with ON
DB Flasher starting with OFF
AC fixed impulse with adjustable
time delay
BC Adjustable impulse with fixed
time delay
F Star-delta change-over
S: screw connection
P: push-in / easy connect
� Control input with voltage-related triggering
� Control input with volt-free triggering
� / � two control input with volt-free triggering
- no triggering
1/39 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
1
Marker label 29.6 x 44.5 mm
Marker label with scale 0-10 48.5 x 44.5 mm
Marker label with scale 0-30 48.5 x 44.5 mm
30
1512
9
6
3
18
27
21
24
0
MT-x50B
30 mm adapters
2C
DC
25
2 0
41
F0
00
92
CD
C 2
52
04
2 F
00
09
2C
DC
25
2 0
43
F0
20
92
CD
C 2
52
04
4 F
02
09
2C
DC
25
2 0
45
F0
20
9
CT-S time relay Potentiometers
Z2
Z3Z1
Note: The connections of the potentiometer are not marked.
Remote potentiometer50 k� ±20 % - 0.2 �, degree of protection IP66
Material Diameter
in mm
Type Order code Price
1 piece
Pack.-unitpieces
Weight 1 pieceg / oz
Plastic, black 22.5 MT-150B 1SFA611410R1506 1 0.040
Plastic, chrome 22.5 MT-250B 1SFA611410R2506 1 0.040
Metal, chrome 22.5 MT-350B 1SFA611410R3506 1 0.048
30 mm adapter for attaching the potentiometer 22 mm in 30 mm mounting hole
Marker label
Material Type Order code Price
1 piece
Pack.-unitpieces
Weight 1 pieceg / oz
Plastic, black KA1-8029 1SFA616920R8029 1
Metal, chrome KA1-8030 1SFA616920R8030 1
Caption Type Order code Price
1 piece
Pack.-unitpieces
Weight 1 pieceg / oz
Symbol (see illustration) SK 615 562-87 GJD6155620R0087 1 0.002
Scale 0 - 10 SK 615 562-88 GJD6155620R0088 1 0.002
Scale 0 - 30 MA16-1060 1SFA611940R1060 1 0.002
Note: Technical specifications see data sheet
2C
DC
25
2 0
39
F0
00
9
2C
DC
25
2 0
40
F0
20
9
CT-S range
Ordering details - Accessories
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 1/40
12
CD
C 2
52
00
8 F
00
10
CT-S range
Ordering details - Accessories
6.5 62.5
60
1011
.5
20
0.25
6”
2.461”
2.362”
70 2.756”
0.39
4”
0.78
7”
0.45
3”
2CD
C 2
52 1
85 F
000522,5
68,5
73,5
.886”
2.70
”
.138”.275”
front-to-backsize 107
22.5 0.89”
68
2.68
”
110.5 4.31”
8 0.32”
4.8 0.19”
front to back
203A11 8
0.31
5”
0.787”
21
18
80.3
14“
0.709“
0.827“
4T22
19.94T22 7.
850.3
09”
0.783”
22.20.874”
ADP.01
COV.01
COV.11
MAR.01
MAR.02
MAR.12
2C
DC
25
2 0
10
F0
01
1
2C
DC
25
2 1
86
F0
00
52
CD
C 2
52
01
0 F
00
10
2C
DC
25
2 0
20
F0
01
0
Accessories for CT-S in new housing (1SVR7...)Description Type Order code Price
1 piece
Pack.-unitpieces
Weight 1 pieceg / oz
Adapter for screw mounting ADP.01 1SVR430029R0100 1 0.018 (0.040)
Sealable transparent cover COV.11 1SVR730005R0100 1 0.004 (0.009)
Marker label for devices w/o DIP switches MAR.01 1SVR366017R0100 10 0.001 (0.002)
Marker label for devices with DIP switches MAR.12 1SVR730006R0000 10 0.001 (0.002)
Accessories for CT-S in old housing (1SVR4...)Description Type Order code Price
1 piece
Pack.-unitpieces
Weight 1 pieceg / oz
Adapter for screw mounting ADP.01 1SVR430029R0100 1 0.018 (0.040)
Sealable transparent cover COV.01 1SVR430005R0100 1 0.004 (0.009)
Marker label for devices w/o DIP switches MAR.01 1SVR366017R0100 10 0.001 (0.002)
Marker label for devices with DIP switches MAR.02 1SVR430043R0000 10 0.001 (0.002)
1/41 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
1
CT-S range
Function diagrams
A ON-delay (Delay on make) CT-MVS, CT-ERS, CT-WBS
A ON-delay (Delay on make) CT-MFS, CT-MBS
A1-A2
15-16, 25-26
21-24 21-22
15-18, 25-28
t < t 2CD
C 2
52 0
17 F
0206
green LED
t = adjusted time delay
A1-A2
15-16, 25-26
21-24 21-22
15-18, 25-28
t1 t3 t2t
X1-Z2
Y1-Z2
2CD
C 2
52 0
18 F
0206
green LED
t = adjusted time delay t1 + t2 = tt3 = pause timing
This function requires continuous control supply voltage for
timing.
Timing begins when control supply voltage is applied. The
green LED flashes during timing. When the selected time
delay is complete, the output relay energizes and the flash-
ing green LED turns steady.
If control supply voltage is interrupted, the output relay de-
energizes and the time delay is reset.
This function requires continuous control supply voltage for
timing.
If control input Y1-Z2 is open, timing begins when control
supply voltage is applied. Or, if control supply voltage is
already applied, opening control input Y1-Z2 also starts tim-
ing. The green LED flashes during timing. When the selected
time delay is complete, the output relay energizes and the
flashing green LED turns steady.
If control input Y1-Z2 closes before the time delay is com-
plete, the time delay is reset and the output relay remains
de-energized.
Pause timing / Accumulative ON-delay (CT-MFS):
Timing can be paused by closing control input X1-Z2. The
elapsed time t1 is stored and continues from this time value
when X1-Z2 is re-opened. This can be repeated as often as
required.
If control supply voltage is interrupted, the output relay de-
energizes and the time delay is reset.
RemarksLegendG Control supply voltage not applied / Output contact open
B Control supply voltage applied / Output contact closed
A1-Y1/B1 Control input with voltage-related triggering
Y1-Z2 Control input with volt-free triggering
X1-Z2 Control input with volt-free triggering
Remote potentiometer connection:When an external potentiometer is connected to the remote
potentiometer connection (terminals Z1-Z2, Z3-Z2 respective-
ly), the internal, front-face potentiometer is disabled and the
time adjustment is made via the external potentiometer.
2nd c/o contact selectable as instantaneous contact:When switch position Inst. “I” is selected, the functionality of
the 2nd c/o contact changes to an instantaneous contact.
It acts like the c/o contacts of a switching relay, i.e. apply-
ing or interrupting the control supply voltage energizes or
de-energizes the c/o contact. The designation of the 2nd c/o
contact changes from 25-26/28 to 21-22/24, when selected
as instantaneous contact.
Terminal designations on the device and in the diagrams:The 1st c/o contact is always designated 15-16/18.
The 2nd c/o contact is designated 25-26/28, if it responds to
the time delay.
If the 2nd c/o contact is selected as an instantaneous con-
tact, the designation 25-26/28 is replaced by 21-22/24.
Control supply voltage is always applied to terminals A1-A2.
Function of the yellow LEDs:On devices without the function ‘2nd c/o contact selectable
as instantaneous contact’, the yellow LED R glows as soon as
the output relay energizes and turns off when the output relay
de-energizes.
Devices with the function ‘2nd c/o contact selectable as
instantaneous contact’ have two yellow LEDs, designated R1
and R2. LED R1 shows the status of the 1st c/o contact (15-
16/18) and LED R2 shows the status of the 2nd c/o contact
(25-26/28, 21-22/24 resp.). LED R1 or R2 glow as soon as
the corresponding output relay energizes and turns off when
the corresponding output relay de-energizes.
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 1/42
1
CT-S range
Function diagrams
B OFF-delay with auxiliary voltage (Delay on break) CT-MFS, CT-MBS, CT-AHS
A1-A2
15-16, 25-26
21-24 21-22
15-18, 25-28
t1 t3 t2t
X1-Z2
Y1-Z2
2CD
C 2
52 0
19 F
0206
green LED
t = adjusted time delay t1 + t2 = tt3 = pause timing
A+ Accumulative ON-delay (Accumulative delay on make) CT-MVS
A1-A2
15-16, 25-26
21-24 21-22
15-18, 25-28
t1 t3 t2t
A1-Y1/B1
2CD
C 2
52 0
43 F
0206
green LED
t = adjusted time delay t1 + t2 = tt3 = pause timing
This function requires continuous control supply voltage for
timing.
Timing begins when control supply voltage is applied. The
green LED flashes during timing. When the selected time
delay is complete, the output relay energizes and the flashing
green LED turns steady.
Timing can be paused by closing control input A1-Y1/B1. The
elapsed time t1 is stored and continues from this time value
when A1-Y1/B1 is re-opened.
This can be repeated as often as required.
If control supply voltage is interrupted, the output relay de-
energizes and the time delay is reset.
This function requires continuous control supply voltage for
timing.
If control input Y1-Z2 is closed, the output relay energizes
immediately. If control input Y1-Z2 is opened, the time delay
starts. The green LED flashes during timing. When the se-
lected time delay is complete, the output relay de- energizes
and the flashing green LED turns steady.
If control input Y1-Z2 closes before the time delay is com-
plete, the time delay is reset and the output relay does not
change state. Timing starts again when control input Y1-Z2
re-opens.
Pause timing / Accumulative OFF-delay (CT-MFS):
Timing can be paused by closing control input X1-Z2. The
elapsed time t1 is stored and continues from this time value
when X1-Z2 is re-opened.
This can be repeated as often as required.
If control supply voltage is interrupted, the output relay de-
energizes and the time delay is reset.
B OFF-delay with auxiliary voltage (Delay on break) CT-MVS, CT-APS
A1-A2
15-16, 25-26
21-24 21-22
15-18, 25-28
t
A1-Y1/B1
< t
2CD
C 2
52 0
20 F
0206
green LED
t = adjusted time delay
B OFF-delay without auxiliary voltage (True delay on break) CT-ARS
A1-A2
15-16, 25-26 15-18, 25-28
t
2CD
C 2
52 0
21 F
0206
green LED
t = adjusted time delay
This function requires continuous control supply voltage for
timing.
If control input A1-Y1/B1 is closed, the output relay energizes
immediately. If control input A1-Y1/B1 is opened, the time
delay starts. The green LED flashes during timing. When the
selected time delay is complete, the output relay de-energizes
and the flashing green LED turns steady.
If control input A1-Y1/B1 recloses before the time delay is
complete, the time delay is reset and the output relay does
not change state. Timing starts again when control input A1-
Y1/B1 re-opens.
If control supply voltage is interrupted, the output relay de-
energizes and the time delay is reset.
The OFF-delay function without auxiliary voltage does not
require continuous control supply voltage for timing. After a
storage time of several months without any voltage, a format-
ting time of about 5 minutes is necessary.
Applying control supply voltage energizes the output relay
immediately. Applied control supply voltage is displayed by
the glowing green LED. If control supply voltage is interrupted,
the OFF-delay starts and the LED turns off. When timing is
complete, the output relay de-energizes.
For correct operation of the unit, it is necessary to complete
the minimum energizing time. As soon as timing starts, the
LED turns off.
1/43 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
1AB Symmetrical ON-delay and OFF-delay (Symmetrical delay on make and delay on break) CT-MFS, CT-MBS
A1-A2
15-16, 25-26
21-24 21-22
15-18, 25-28
t1a t3 t1bt1
X1-Z2
Y1-Z2
t2 t2a t3 t2b
2CD
C 2
52 0
22 F
0206
green LED
t1 = adjusted ON-delayt2 = adjusted OFF-delayt1 = t2
t1a + t1b = t1t2a + t2b = t2t3 = pause timing
AB Symmetrical ON-delay and OFF-delay (Symmetrical delay on make and delay on break) CT-MVS
A1-A2
15-16, 25-26
21-24 21-22
15-18, 25-28
t1
A1-Y1/B1
t2 t1 < t2
2CD
C 2
52 0
23 F
0206
green LED
t1 = adjusted ON-delayt2 = adjusted OFF-delayt1 = t2
This function requires continuous control supply voltage for
timing.
Closing control input Y1-Z2 starts the ON-delay t1. When tim-
ing is complete, the output relay energizes. Opening control
input Y1-Z2 starts the OFF-delay t2. Both timing functions are
displayed by the flashing green LED. When the OFF-delay t2 is
complete, the output relay de-energizes.
If control input Y1-Z2 opens before the ON-delay t1 is com-
plete, the time delay is reset and the output relay remains de-
energized. If control input Y1-Z2 closes before the OFF-delay
t2 is complete, the time delay is reset and the output relay
remains energized.
Pause timing / Accumulative, symmetrical ON-delay and
OFF-delay (CT-MFS): Timing can be paused by closing control
input X1-Z2. The elapsed time t1a
or t2a
is stored and contin-
ues from this time value when X1-Z2 is re-opened. This can
be repeated as often as required.
If control supply voltage is interrupted, the output relay de-
energizes and the time delay is reset.
This function requires continuous control supply voltage for
timing.
Closing control input A1-Y1/B1 starts the ON-delay t1. When
timing is complete, the output relay energizes. Opening
control input A1-Y1/B1 starts the OFF-delay t2. Both timing
functions are displayed by the flashing green LED. When the
OFF-delay t2 is complete, the output relay de-energizes.
If control input A1-Y1/B1 opens before the ON-delay t1 is
complete, the time delay is reset and the output relay re-
mains de-energized. If control input A1-Y1/B1 closes before
the OFF-delay t2 is complete, the time delay is reset and the
output relay remains energized.
If control supply voltage is interrupted, the output relay de-
energizes and the time delay is reset.
CT-S range
Function diagrams
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 1/44
1CA Impulse-ON (Interval) CT-MVS, CT-WBS
A1-A2
15-16, 25-26
21-24 21-22
15-18, 25-28
t < t 2CD
C 2
52 0
24 F
0206
green LED
t = adjusted pulse time
AB Asymmetrical ON-delay and OFF-delay (Asymmetrical delay on make and delay on break) CT-MXS
A1-A2
15-16, 25-2615-18, 25-28
t1
A1-Y1/B1
t2 t1 < t2 2CD
C 2
52 0
38 F
0206
green LED
t1 = adjusted ON-delayt2 = adjusted OFF-delayt1 and t2 independently adjustable
This function requires continuous control supply voltage for
timing.
Closing control input A1-Y1/B1 starts the ON-delay t1. When
timing is complete, the output relay energizes. Opening
control input A1-Y1/B1 starts the OFF-delay t2. When the
OFF-delay is complete, the output relay de-energizes. Both
timing functions are displayed by the flashing green LED. The
ON-delay and OFF-delay are independently adjustable.
If control input A1-Y1/B1 opens before the ON-delay is com-
plete (<t1), the time delay is reset and the output relay remains
de-energized.
If control input A1-Y1/B1 closes before the OFF-delay is com-
plete (<t2), the time delay is reset and the output relay remains
energized.
If control supply voltage is interrupted, the output relay de-
energizes and the time delay is reset.
This function requires continuous control supply voltage for
timing.
The output relay energizes immediately when control supply
voltage is applied and de-energizes after the set pulse time
is complete. The green LED flashes during timing. When
the selected pulse time is complete, the flashing green LED
turns steady.
If control supply voltage is interrupted, the output relay de-
energizes and the time delay is reset.
CA Impulse-ON (Interval) CT-MFS, CT-MBS
CB Impulse-OFF with auxiliary voltage (Trailing edge interval) CT-MFS, CT-MBS
A1-A2
15-16, 25-26
21-24 21-22
15-18, 25-28
t1 t3 t2t
X1-Z2
Y1-Z2
2CD
C 2
52 0
25 F
0206
green LED
t = adjusted pulse time t1 + t2 = tt3 = pause timing
A1-A2
15-16, 25-26
21-24 21-22
15-18, 25-28
t1 t3 t2t
X1-Z2
Y1-Z2
2CD
C 2
52 0
26 F
0206
green LED
t = adjusted pulse time t1 + t2 = tt3 = pause timing
This function requires continuous control supply voltage for
timing.
The output relay energizes immediately when control supply
voltage is applied and de-energizes after the set pulse time is
complete. If control input Y1-Z2 is open, timing begins when
control supply voltage is applied. Or, if control supply voltage
is already applied, opening control input Y1-Z2 starts timing.
The green LED flashes during timing. When the selected pulse
time is complete, the output relay de-energizes and the flash-
ing green LED turns steady.
Closing control input Y1-Z2, before the pulse time is com-
plete, de-energizes the output relay and resets the pulse time.
Pause timing / Accumulative impulse-ON (CT-MFS):
Timing can be paused by closing control input X1-Z2. The
elapsed time t1 is stored and continues from this time value
when X1-Z2 is re-opened.
This can be repeated as often as required.
If control supply voltage is interrupted, the output relay de-
energizes and the time delay is reset.
This function requires continuous control supply voltage for
timing.
If control supply voltage is applied, opening control input Y1-
Z2 energizes the output relay immediately and starts timing.
The green LED flashes during timing. When the selected pulse
time is complete, the output relay de-energizes and the flash-
ing green LED turns steady.
Closing control input Y1-Z2, before the pulse time is com-
plete, de-energizes the output relay and resets the pulse time.
Pause timing / Accumulative impulse-OFF (CT-MFS):
Timing can be paused by closing control input X1-Z2. The
elapsed time t1 is stored and continues from this time value
when X1-Z2 is re-opened.
This can be repeated as often as required.
If control supply voltage is interrupted, the output relay de-
energizes and the time delay is reset.
CT-S range
Function diagrams
1/45 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
1
DB Flasher, starting with the OFF time (Recycling equal times, OFF first) CT-WBS
DA Flasher, starting with the ON time (Recycling equal times, ON first) CT-WBS
A1-A2
15-16, 25-26 15-18, 25-28
t t
2CD
C 2
52 0
29 F
0206
green LED
t = adjusted flashing time
A1-A2
15-16, 25-26 15-18, 25-28
t t
2CD
C 2
52 0
30 F
0206
green LED
t = adjusted flashing time
Applying control supply voltage starts timing with symmetrical
ON & OFF times. The cycle starts with an ON time first. The
ON & OFF times are displayed by the flashing green LED,
which flashes twice as fast during the OFF time.
If control supply voltage is interrupted, the output relay de-
energizes and the time delay is reset.
Applying control supply voltage starts timing with symmetri-
cal ON & OFF times. The cycle starts with an OFF time first.
The ON & OFF times are displayed by the flashing green
LED, which flashes twice as fast during the OFF time.
If control supply voltage is interrupted, the output relay de-
energizes and the time delay is reset.
CB Impulse-OFF with auxiliary voltage (Trailing edge interval) CT-MVS
CE Impulse-ON and impulse-OFF (Interval and trailing edge interval) CT-MXS
A1-A2
15-16, 25-26
21-24 21-22
15-18, 25-28
t
A1-Y1/B1
< t
2CD
C 2
52 0
27 F
0206
green LED
t = adjusted pulse time
A1-A2
15-16, 25-26 15-18, 25-28
t1 < t1t2
A1-Y1/B1
2CD
C 2
52 0
28 F
0206
green LED
t1 = adjusted pulse time 1t2 = adjusted pulse time 2
This function requires continuous control supply voltage for
timing.
If control supply voltage is applied, opening control input A1-
Y1/B1 energizes the output relay immediately and starts tim-
ing. The green LED flashes during timing. When the selected
pulse time is complete, the output relay de-energizes and the
flashing green LED turns steady.
Closing control input A1-Y1/B1, before the pulse time is com-
plete, de-energizes the output relay and resets the pulse time.
If control supply voltage is interrupted, the output relay de-
energizes and the time delay is reset.
This function requires continuous control supply voltage for
timing. If control supply voltage is applied, closing control
input A1-Y1/B1 energizes the output relay immediately and
starts the pulse time t1. The green LED flashes during timing.
When t1 is complete, the output relay de-energizes and the
flashing green LED turns steady. Re-opening control input
A1-Y1/B1 energizes the output relay immediately and starts
the pulse time t2. The green LED flashes during timing. When
t2 is complete, the output relay de-energizes and the flashing
green LED turns steady. t1 and t
2 are independently adjust-
able. If control input A1-Y1/B1 changes state before the pulse
time is complete, the output relay de-energizes and the pulse
time is reset. If control input A1-Y1/B1 changes state again,
the interrupted pulse time restarts. If control supply voltage is
interrupted, the output relay de-energizes and the time delay
is reset.
CT-S range
Function diagrams
DB Flasher with reset, starting with the OFF time (Recycling equal times with reset, OFF first) CT-MFS, CT-MBS
A1-A2
Y1-Z2
15-16, 25-26 15-18, 25-28
21-22 21-24
t t t t
2CD
C 2
52 0
32 F
0206
green LED
t = adjusted flashing time
Applying control supply voltage starts timing with symmetri-
cal ON & OFF times. The cycle starts with an OFF time first.
The ON & OFF times are displayed by the flashing green LED,
which flashes twice as fast during the OFF time.
The time delay can be reset by closing control input Y1-Z2.
Opening control input Y1-Z2 starts the timer pulsing again
with symmetrical ON & OFF times.
If control supply voltage is interrupted, the output relay de-
energizes and the time delay is reset.
DA Flasher with reset, starting with the ON time (Recycling equal times with reset, ON first) CT-MFS, CT-MBS
A1-A2
Y1-Z2
15-16, 25-26 15-18, 25-28
21-22 21-24
t t t t
2CD
C 2
52 0
31 F
0206
green LED
t = adjusted flashing time
Applying control supply voltage starts timing with symmetrical
ON & OFF times. The cycle starts with an ON time first. The
ON & OFF times are displayed by the flashing green LED,
which flashes twice as fast during the OFF time.
The time delay can be reset by closing control input Y1-Z2.
Opening control input Y1-Z2 starts the timer pulsing again
with symmetrical ON & OFF times.
If control supply voltage is interrupted, the output relay de-
energizes and the time delay is reset.
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 1/46
1DE Flasher, starting with the ON or OFF time (Recycling equal times, ON or OFF first) CT-MVS
H Pulse former (Single shot) CT-MFS, CT-MBS
A1-A2
A1-Y1/B1
15-16, 25-26 15-18, 25-28
21-22 21-24
t t t t
2CD
C 2
52 0
33 F
0206
green LED
t = adjusted flashing time
A1-A2
15-16, 25-26
21-24 21-22
15-18, 25-28
t t
Y1-Z2
2CD
C 2
52 0
34 F
0206
green LED
t = adjusted pulse time
Applying control supply voltage starts timing with symmetri-
cal ON & OFF times. The cycle starts with an ON time first.
Closing control input A1-Y1/B1, with control supply voltage
applied, starts the cycle with an OFF time first. The ON &
OFF times are displayed by the flashing green LED, which
flashes twice as fast during the OFF time.
If control supply voltage is interrupted, the output relay de-
energizes and the time delay is reset.
This function requires continuous control supply voltage for
timing.
Closing control input Y1-Z2 energizes the output relay im-
mediately and starts timing. Operating the control contact
switch Y1-Z2 during the time delay has no effect. The green
LED flashes during timing. When the selected ON time is
complete, the output relay de-energizes and the flashing
green LED turns steady. After the ON time is complete, it
can be restarted by closing control input Y1-Z2.
If control supply voltage is interrupted, the output relay de-
energizes and the time delay is reset.
CT-S range
Function diagrams
H Pulse former (Single shot) CT-MVS
A1-A2
15-16, 25-26
21-24 21-22
15-18, 25-28
t t
A1-Y1/B1
2CD
C 2
52 0
35 F
0206
green LED
t = adjusted pulse time
This function requires continuous control supply voltage for
timing.
Closing control input A1-Y1/B1 energizes the output relay
immediately and starts timing. Operating the control contact
switch A1-Y1/B1 during the time delay has no effect. The
green LED flashes during timing. When the selected ON time
is complete, the output relay de-energizes and the flashing
green LED turns steady. After the ON time is complete, it
can be restarted by closing control input A1-Y1/B1.
If control supply voltage is interrupted, the output relay de-
energizes and the time delay is reset.
ED Pulse generator, starting with the ON or OFF time (Recycling unequal times, ON or OFF first) CT-MXS
A1-A2
A1-Y1/B1
15-16, 25-26 15-18, 25-28
t1 t1t2 t2
2CD
C 2
52 0
75 F
0207
green LED
t1 = adjusted OFF timet2 = adjusted ON time
This function requires continuous control supply voltage for
timing.
Applying control supply voltage, with open control input
A1-Y1/B1, starts timing with an ON time t2 first. Applying
control supply voltage, with closed control input A1-Y1/B1,
starts timing with an OFF time t1 first. The ON & OFF times
are displayed by the flashing green LED, which flashes twice
as fast during the OFF time.
The ON & OFF times are independently adjustable.
If control supply voltage is interrupted, the output relay de-
energizes and the time delay is reset.
1/47 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
1EC Single-pulse generator, starting with the OFF time (Delay on make with interval output) CT-MXS
AC Fixed impulse with adjustable time delay (Delayed pulse output) CT-WBS
A1-A2
A1-Y1/B1
15-16, 25-26 15-18, 25-28
t1 t2 t2t1
2CD
C 2
52 0
37 F
0206
green LED
t1 = adjusted OFF timet2 = adjusted ON timet1 and t2 independently adjustable
A1-A2
t1 < t1t2
15-18, 25-28 15-16, 25-26
2CD
C 2
52 0
41 F
0206
green LED
t1 = adjusted time delayt2 = pulse time fixed 500 ms
This function requires continuous control supply voltage for
timing.
Applying control supply voltage, or, if control supply voltage is
already applied, opening control input A1-Y1/B1 energizes the
output relay after the OFF time t1 is complete. When the fol-
lowing ON time t2 is complete, the output relay de-energizes.
The ON & OFF times are displayed by the flashing green LED,
which flashes twice as fast during the OFF time.
The ON & OFF times are independently adjustable.
Closing control input A1-Y1/B1, with control supply voltage
applied, de-energizes the output relay and resets the time
delay.
If control supply voltage is interrupted, the output relay de-
energizes and the time delay is reset.
This function requires continuous control supply voltage for
timing.
The time delay t1 starts when control supply voltage is ap-
plied. The green LED flashes during timing. When t1 is com-
plete, the output relay energizes for the fixed impulse time t2
of 500 ms and the flashing green LED turns steady.
If control supply voltage is interrupted, the time delay is reset.
The output relay does not change state.
CT-S range
Function diagrams
BC Adjustable impulse with fixed time delay (Delayed Interval) CT-WBS
G ON/OFF-Function CT-MFS, CT-MBS, CT-MVS, CT-MXS, CT-WBS
A1-A2
t2 t2 < t1t1
15-18, 25-28 15-16, 25-26
2CD
C 2
52 0
42 F
0206
green LED
t1 = adjusted pulse timet2 = time delay fixed 500 ms
A1-A2
15-16, 25-26 15-18, 25-28
2CD
C 2
52 0
44 F
0206
green LED
Time sector ≠ 300 h Time sector = 300 h
This function requires continuous control supply voltage for
timing.
Applying control supply voltage starts the fixed time delay t2 of
500 ms. When t2 is complete, the output relay energizes and
the selected pulse time t1 starts. The green LED flashes dur-
ing timing. When t1 is complete, the output relay de-energizes
and the flashing green LED turns steady.
If control supply voltage is interrupted, the pulse time is reset.
The output relay does not change state.
This function is used for test purposes during commissioning
and troubleshooting.
If the selected max. value of the time range is smaller than
300 h (front-face potentiometer “Time sector” 300 h), apply-
ing control supply voltage energizes the output relay imme-
diately and the green LED glows. Interrupting control supply
voltage, de-energizes the output relay.
If the selected max. value of the time range is 300 h (front-
face potentiometer “Time sector” = 300 h) and control supply
voltage is applied, the green LED glows, but the output relay
does not energize.
Time settings and operating of the control inputs have no ef-
fect on the operation.
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 1/48
1
K1T
K1T
K3
K3
Y � N
K2
K2
K2
L1
N
F3
F2
95
96
21
22
22
21
A1
A2
A1
A2
A1
A2
A1
A2
22
21
13
14
17
18
17
28
13
14
13
14
53
54
S10
IS2
K1
K1
K1
2CD
C 2
52 1
28 F
0b06
-K1-K3
L1
-F1
1
2
95
96
97
98
L2
3
4
L3
5
6
1
2
3
4
5
6
1
2
3
4
5
6-K2
-F2
1
2
3
4
5
6
1
3
5
2
4
6
M
3 ~
W2V2U2
W1V1U1
-M1
2CD
C 2
53 0
09 F
0012
K1T
K1T
K3
K3
Y � N
K2
K2
K2
L1
N
F3
F2
95
96
21
22
22
21
A1
A2
A1
A2
A1
A2
A1
A2
22
21
13
14
15
18
25
28
13
14
13
14
53
54
S10
IS2
K1
K1
K1
2CD
C 2
52 1
29 F
0b06
F Star-delta change-over (Star-delta starting) CT-SDS
A1-A2
t1 t2
2CD
C 2
52 0
40 F
0206
green LED
t1 = adjusted starting timet2 = transition time (50 ms)
17-18
17-28
This function requires continuous control supply voltage for timing.
Applying control supply voltage to terminals A1-A2, energizes the
star contactor connected to terminals 17-18 and begins the set
starting time t1. The green LED flashes during timing. When the
starting time is complete, the first output contact de-energizes the
star contactor.
Now, the fixed transition time t2 of 50 ms starts. When the transi-
tion time is complete, the second output contact energizes the
delta contactor connected to terminals 17-28. The delta contactor
remains energized as long as control supply voltage is applied to
the unit.
Power circuit diagram
Control circuit diagram
Control circuit diagram
CT-S range
Function diagrams
FC Star-delta change-over with impulse function (Star-delta starting, interval/delay on make) CT-MFS, CT-MBS, CT-MVS.2x
A1-A2
15-16
25-26
t1 t2 2CD
C 2
52 0
39 F
0206
green LED
t1 = adjusted starting timet2 = transition time (50 ms)
15-18
25-28
This function requires continuous control supply voltage for timing.
Applying control supply voltage to terminals A1-A2, energizes the
star contactor connected to terminals 15-18 and begins the set
starting time t1. The green LED flashes during timing. When the
starting time is complete, the first c/o contact de-energizes the star
contactor.
Now, the fixed transition time t2 of 50 ms starts. When the transition
time is complete, the second c/o contact energizes the delta con-
tactor connected to terminals 25-28. The delta contactor remains
energized as long as control supply voltage is applied to the unit.
1/49 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
1CT-MVS.21 CT-MVS.22 CT-MVS.12
CT-MXS.22
2CD
C 2
52 0
02 F
0b06A1
A1Y1/B1 15
A2 16 18
15Z2
18 16 A2
Y1/B1 Z125 21
28 24 26 22
2125
26 2822 24
A1
A1Y1/B1 15 25
A2 16 18 26 28
15
28 26
25
18 16 A2
Y1/B1
2CD
C 2
52 0
03 F
0b06 A1
A1Y1/B1 15
A2 16 18
15 Y1/B1
18 16 A2
2CD
C 2
52 0
04 F
0b06
A1
A1Y1/B1 15 25
A2 16 18 26 28
15Z2
28 26 Y1/B1
25
18 16 A2
Z3 Z1
2CD
C 2
52 0
05 F
0b06
A1
A1Y1/B1 15 25
A2 16 18 26 28
15
28 26
25
18 16 A2
Y1/B1
2CD
C 2
52 0
03 F
0b06
CT-MVS.23
A1
A1 15 2125
A2 16 18 26 2822 24
15Z2
28 2624 22 Y1
Z1
18 16 A2
X125 21
2CD
C 2
52 0
06 F
0b06 A1
A1 15 2125
A2 16 18 26 2822 24
15Z2
28 2624 22 Y1
Z1
18 16 A2
25 21
2CD
C 2
52 0
07 F
0b06 A1
A1 15 25
A2 16 18 26 28
15
28 26
25
18 16 A2
2CD
C 2
52 0
08 F
0b06
CT-MFS.21 CT-MBS.22 CT-WBS.22
A CT-ERS.21
A1
A1 15
A2 16 18
15
18 1628 26
A2
25
25
26 28 2CD
C 2
52 0
09 F
0b06 A1
A1
A2 16 18
15
15
18 16 A2
2CD
C 2
52 0
10 F
0b06
A CT-ERS.22 A CT-ERS.12
A1
A1 15
A2 16 18
15
18 1628 26
A2
25
25
26 28 2CD
C 2
52 0
09 F
0b06
CT-S range
Connection diagrams
A1-A2 Supply: 24-240 V AC/DC
A1-Y1/B1 Control input
15-16/18 1. c/o contact
25-26/28 2. c/o contact
21-22/24 2. c/o contact as instantaneous contact
Z1-Z2 Remote potentiometer connection
A1-A2 Supply: 24-240 V AC/DC
15-16/18 1. c/o contact
25-26/28 2. c/o contact
21-22/24 2. c/o contact as instantaneous contact
Y1-Z2 Control input
X1-Z2 Control input
Z1-Z2 Remote potentiometer connection
A1-A2 Supply: 24-48 V DC or 24-240 V AC
15-16/18 1. c/o contact
25-26/28 2. c/o contact
21-22/24 2. c/o contact as instantaneous contact
Y1-Z2 Control input
Z1-Z2 Remote potentiometer connection
A1-A2 Supply: 24-48 V DC or 24-240 V AC
15-16/18 1. c/o contact
25-26/28 2. c/o contact
A1-A2 Supply: 24-240 V AC/DC
15-16/18 1. c/o contact
25-26/28 2. c/o contact
A1-A2 Supply: 24-48 V DC or 24-240 V AC
15-16/18 1. c/o contact
25-26/28 2. c/o contact
A1-A2 Supply: 24-48 V DC or 24-240 V AC
15-16/18 1. c/o contact
A1-A2 Supply: 24-48 V DC or 24-240 V AC
A1-Y1/B1 Control input
15-16/18 1. c/o contact
25-26/28 2. c/o contact
Z1-Z2 Remote potentiometer connection
Z3-Z2 Remote potentiometer connection
A1-A2 Supply: 224-48 V DC or 24-240 V AC
A1-Y1/B1 Control input
15-16/18 1. c/o contact
25-26/28 2. c/o contact
A1-A2 Supply: 380-440V AC
A1-Y1/B1 Control input
15-16/18 1. c/o contact
25-26/28 2. c/o contact
A1-A2 Supply: 24-48 V DC or 24-240 V AC
A1-Y1/B1 Control input
15-16/18 1. c/o contact
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 1/50
1B CT-APS.21 B CT-APS.22 B CT-AHS.22
B CT-ARS.11
A1
Y1/B1 A1 15 25
A2 16 18 26 28
15Y1/B1
2628
25
18 16 A2
2CD
C 2
52 0
11 F
0b06 A1
A1 15 25
A2 16 18 26 28
15Z2
2628
25
18 16 A2Y1
2CD
C 2
52 0
13 F
0b06
15A1
A1
A2 16 18
15
18 16 A2
2CD
C 2
52 0
14 F
0b06
A1
Y1/B1 A1
A2 16 18
15
15 Y1/B1
18 16 A2
2CD
C 2
52 0
12 F
0b06
B CT-APS.12
A1
A1 15 25
A2 16 18 26 28
15
2628
25
18 16 A2
2CD
C 2
52 0
15 F
0b06
B CT-ARS.21 F CT-SDS.22
A1
A1
A2 18 28
17
17
18 28 A2
2CD
C 2
52 0
16 F
0b06
F CT-SDS.23
A1
Y1/B1 A1 15 25
A2 16 18 26 28
15Y1/B1
2628
25
18 16 A2
2CD
C 2
52 0
11 F
0b06
A1
A1
A2 18 28
17
17
18 28 A2
2CD
C 2
52 0
16 F
0b06
CT-S range
Connection diagrams
A1-A2 Supply: 24-240 V AC/DC
A1-Y1/B1 Control input
15-16/18 1. c/o contact
25-26/28 2. c/o contact
A1-A2 Supply: 24-240 V AC/DC
15-16/18 1. c/o contact
25-26/28 2. c/o contact
A1-A2 Supply: 24-48 V DC or 24-240 V AC
17-18 1. n/o contact
17-28 2. n/o contact
A1-A2 Supply: 380-440 V AC
17-18 1. n/o contact
17-28 2. n/o contact
A1-A2 Supply: 24-48 V DC or 24-240 V AC
A1-Y1/B1 Control input
15-16/18 1. c/o contact
25-26/28 2. c/o contact
A1-A2 Supply: 24-48 V DC or 24-240 V AC
A1-Y1/B1 Control input
15-16/18 1. c/o contact
A1-A2 Supply: 24-240 V AC/DC
15-16/18 1. c/o contact
A1-A2 Supply: 24-48 V DC or 24-240 V AC
Y1-Z2 Control input
15-16/18 1. c/o contact
25-26/28 2. c/o contact
1/51 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
1Data at T
a = 25 °C and rated values, unless otherwise indicated
CT-S
Input circuit - Supply circuitRated control supply voltage U
sCT-xxx.x1 24-240 V AC/DC
CT-xxx.x2 24-48 V DC, 24-240 V AC
CT-xxx.x3 380-440 V AC
CT-xxx.x4 110-240 V AC
CT-xxx.x5 220-240 V AC
CT-xxx.x6 24 V AC/DC
CT-xxx.x7 100-127 V AC or 110 V DC
CT-xxx.x8 200-240V AC/DC
Rated control supply voltage US tolerance -15...+10 %
Rated frequency DC or 50/60 Hz
Frequency range AC 47-63 Hz
Typical current / power consumption depending on device, see data sheet
Power failure buffering time 24 V DC min. 15 ms
230/400 V AC min. 20 ms
Minimum energizing time 100 ms (CT-ARS)
Formatting time 1) 5 min (CT-ARS)
Input circuit - Control circuitKind of triggering CT-MVS, CT-MXS, CT-APS voltage-related triggering
Control input, Control function A1-Y1/B1 start timing external
Parallel load / polarized yes / no
Maximum cable length to the control input 50 m - 100 pF/m
Minimum control pulse length 20 ms
Control voltage potential see rated control supply voltage
Current consumption of the control input 24 V DC 1.2 mA
230 V AC 8 mA
400 V AC 6 mA
Kind of triggering CT-MFS, CT-MBS, CT-AHS volt-free triggering
Control input, Control function Y1-Z2 start timing external
X1-Z2 pause timing / accumulative functions (CT-MFS)
Maximum switching current in the control circuit 1 mA
Maximum cable length to the control input 50 m - 100 pF/m
Minimum control pulse length 20 ms
No-load voltage at the control inputs 10-40 V DC
Remote potentiometerRemote potentiometer connections, Resistance value Z1-Z2 50 kΩ (CT-MFS, CT-MBS, CT-MVS.21, CT-MXS)
Z3-Z2 50 kΩ (CT-MXS)
Maximum cable length to remote potentiometer 2 x 25 m, shielded with 100 pF/m
Shield connection Z2
Timing circuitTime ranges 10 time ranges 0.05 s - 300 h 1.) 0.05-1 s 2.) 0.15-3 s 3.) 0.5-10 s 4.) 1.5-30 s 5.) 5-100 s
6.) 15-300 s 7.) 1.5-30 min 8.) 15-300 min 9.) 1.5-30 h 10.) 15-300 h
7 time ranges 0.05 s - 10 min (CT-SDS, CT-ARS)
1.) 0.05-1 s 2.) 0.15-3 s 3.) 0.5-10 s4.) 1.5-30 s 5.) 5-100 s 6.) 15-300 s 7.) 0.5-10 min
Recovery time 24-240 V AC/DC < 50 ms
24-48 V DC, 24-240 V AC < 80 ms
380-440 V AC < 60 ms
Accuracy within the rated control supply voltage tolerance �t < 0.004 % / V
Accuracy within the temperature range �t < 0.03 % / °C
Repeat accuracy (constant parameters) < ±0.2 %
Star-delta transition time fixed 50 ms (CT-SDS, CT-MBS, CT-MFS, CT-MVS.2x)
Star-delta transition time tolerance ±2 ms
CT-S range
Technical data
1) prior to first commisioning and after a six-month stop in operation
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 1/52
1
CT-S range
Technical data
Indication of operational statesControl supply voltage / timing U/T: green LED V: control supply voltage applied / W: timing
Control supply voltage U: green LED V: control supply voltage applied
Relay state R, R1, R2: yellow LED V: output relay energized
Output circuitKind of output 15-16/18 relay, 1 c/o contact
15-16/18; 25-26/28 relay, 2 c/o contacts
15-16/18; 25(21)-26(22)/28(24) relay, 2 c/o contacts, 2nd c/o contact selectable as inst. contact
17-18; 17-28 relay, 2 n/o contacts (CT-SDS)
Contact material Cd-free, on request
Rated operational voltage Ue
IEC/EN 60947-1 250 V
Minimum switching voltage / minimum switching current 12 V / 10 mA
Maximum switching voltage / maximum switching current see load limit curves
Rated operational current Ie
(IEC/EN 60947-5-1 )AC-12 (resistive) at 230 V 4 A
AC-15 (inductive) at 230 V 3 A
DC-12 (resistive) at 24 V 4 A
DC-13 (inductive) at 24 V 2 A (CT-ARS; 1.5 A)
AC rating (UL 508) Utilization category (Control Circuit Rating Code)B 300
max. rated operational voltage 300 V AC
Maximum continuous thermal current at B300 5 A
max. making/breaking apparent power at B300 3600 VA / 360 VA
Mechanical lifetime 30 x 106 switching cycles
Electrical lifetime at AC-12, 230 V, 4 A 0.1 x 106 switching cycles
Max. fuse rating to achieve short-circuit protection (IEC/EN 60947-5-1)
n/c contact 6 A fast-acting
n/o contact 10 A fast-acting
General data 2)
MTBF on request
Duty time 100%
Dimensions (W x H x D) product dimensions 22.5 x 85.6 x 103.7 mm (0.89 x 3.37 x 4.08 in)
packaging dimensions 97 x 109 x 30 mm (3.82 x 4.29 x 1.18 in)
Weight depending on device, see ordering details
Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool
Mounting position any
Minimum distance to other units vertical / horizontal not necessary / not necessary
Material of housing UL 94 V-0
Degree of protection housing / terminals IP50 / IP20
Electrical connection 2)
Screw connection technology Easy Connect Technology
(Push-in)Wire size fine-strand with(out) wire end
ferrule1 x 0.5-2.5 mm2 (1 x 20-14 AWG)2 x 0.5-1.5 mm2 (2 x 20-16 AWG)
2 x 0.5-1.5 mm2 (2 x 20-16 AWG)
rigid 1 x 0.5-4 mm2 (1 x 20-12 AWG)2 x 0.5-2.5 mm2 (2 x 20-14 AWG)
2 x 0.5-1.5 mm2 (2 x 20-16 AWG)
Stripping length 8 mm (0.32 in)
Tightening torque 0.6-0.8 Nm (5.31-7.08 lb.in) -
2) Data for all references 1SVR 730 xxx xxx and 1SVR 740 xxx xxx. For devices with 1SVR 430 xxx xxx please refer to the data sheet.
1/53 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
1
CT-S range
Technical data
Environmental dataAmbient temperature ranges operation / storage -25...+60 °C / -40...+85 °C,
-40...+60 °C / -40...+85 °C (CT-MVS.21, CT-MFS.21, CT-ERS.21, CT-APS.21)
Damp heat (cyclic) (IEC/EN 60068-2-30) 6 x 24 h cycle, 55 °C, 95 % RH
Vibration, sinusoidal (IEC/EN 60068-2-6) functioning 40 m/s2, 10-58/60-150 Hz
resistance 60 m/s2, 10-58/60-150 Hz, 20 cycles
Vibration, seismic (IEC/EN 60068-3-3) functioning 20 m/s2
Shock, half-sine (IEC/EN 60068-2-27) functioning 100 m/s2, 11 ms, 3 shocks/direction
resistance 300 m/s2 , 11 ms, 3 shocks/direction
Isolation data CT-S with 1 c/o CT-S with 2 c/oRated insulation voltage U
iinput circuit / output circuit 500 V
output circuit 1 / output circuit 2 not available 300 V
Rated impulse withstand voltage Uimp
between all isolated circuits (IEC/EN 60664-1)
type test: 4 kV; 1.2/50 μs
Power-frequency withstand voltage (test voltage) between all isolated circuits
routine test: 2.0 kV; 50 Hz; 1 stype test: 2.0 kV; 50 Hz; 60 s
Basic insulation (IEC/EN 61140) input circuit / output circuit 500 V
Protective separation (IEC/EN 61140; EN 50178)
input circuit / output circuit 250 V
Pollution degree IEC/EN 60664-1 3
Overvoltage category IEC/EN 60664-1 III
StandardsProduct standard IEC 61812-1, EN 61812-1 + A11, DIN VDE 0435 part 2021
Low Voltage Directive 2006/95/EC
EMC Directive 2004/108/EC
RoHS Directive 2011/65/EC
Electromagnetic compatibilityInterference immunity to IEC/EN 61000-6-1, IEC/EN 61000-6-2
electrostatic discharge IEC/EN 61000-4-2 Level 3, 6 kV / 8 kV
radiated, radio-frequency electromagnetic field
IEC/EN 61000-4-3 Level 3, 10 V/m (1 GHz) 3 V/m (2 GHz) 1 V/m (2.7 GHz)
electrical fast transient / burst IEC/EN 61000-4-4 Level 3, 2 kV / 5 kHz
surge IEC/EN 61000-4-5 Level 4, 2 kV A1-A2
conducted disturbances, induced by radio-frequency fields
IEC/EN 61000-4-6 Level 3, 10 V
harmonics and interharmonics IEC/EN 61000-4-13 Class 3
Interference emission IEC/EN 61000-6-3, IEC/EN 61000-6-4
high-frequency radiated IEC/CISPR 22, EN 55022 Class B
high-frequency conducted IEC/CISPR 22, EN 55022 Class B
„Approvals and marks“ see page 1/4.
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 1/54
1
CT-S range
Technical diagrams
AC load (resistive) DC load (resistive)
Technical diagrams
Load limit curves
Derating factor F for inductive AC load Contact lifetime
DC current [A]
resistive load
DC
voltage [V
]
2C
DC
252 1
50 F
0206
cos ϕ
0.5
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
0.6
0.7
0.8
0.9
1.0
Dera
ting facto
r F
2C
DC
252 1
24 F
0206
AC current [A]
resistive loadAC
voltage [V
]
2C
DC
252 1
49 F
0206
Switching current [A]
250 V
resistive load
Sw
itchin
g c
ycle
s
2C
DC
252 1
48 F
0206
1/55 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
1
CT-S range
Wiring notes, Dimensional drawings
2CD
C 2
52 1
88 F
0b05
100
102
109,5 4.31“ 22,5
.886“
78
3.07
“
4.02“
3.94“
L(+)
N(-)
A1 Y1
Z2
X1
A2
2C
DC
25
2 1
01
F0
b0
6
L(+)
N(-)
A1 Y1/B1
A2
2C
DC
25
2 1
02
F0
b0
6 L(+) L(+)
N(-) L(-)
A1 Y1/B1
A2
2C
DC
25
2 1
03
F0
b0
6
L(+)
N(-)
A1 Z1
Z2
Z3
A2
2C
DC
25
2 1
04
F0
b0
6
L(+) +V
N(-) 0 V
A1 Y1
Z2A2
2C
DC
25
2 1
05
F0
b0
6
Wiring notes
Remote potentiometer
Control inputs (volt-free triggering)
Control inputs (voltage-related triggering)
Triggering of the control inputs (volt-free) with a proximity switch (3 wire)
The control input Y1/B1 is triggered with electric potential against A2. It is pos-
sible to use the control supply voltage from terminal A1 or any other voltage
within the rated control supply voltage range.
113.4 4.47”
22.5 0.89”
85.6
3
.37”
103.7 4.08”
105.9 4.17”
2C
DC
25
2 0
09
F0
01
1
1SVR 430 xxx xxx 1SVR 730 xxx xxx, 1SVR 740 xxx xxx
Dimensional drawing Dimensions in mm
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 1/56
1
Electronic timers
Notes
2/1 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Measuring and monitoring relays
Product group picture
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/2
2
Measuring and monitoring relays
Table of contents
Measuring and monitoring relaysBenefits and advantages 2/3
Monitoring features and application ranges 2/5
Approvals and marks 2/7
Current and voltage monitoring relays, single-phase ........................... 2/9
Three-phase monitoring relays ........................................................ 2/27
Grid feeding monitoring relays -
Voltage and frequency monitoring functions ..................................... 2/49
Insulation monitoring relays for unearthed supply systems ................ 2/59
Motor load monitoring relays ........................................................... 2/73
Motor control and protection ........................................................... 2/79
Thermistor motor protection relays .................................................. 2/85
Temperature monitoring relays ......................................................... 2/97
Liquid level monitors and controls.................................................. 2/109
General technical data, Accessories, Current transformers ............. 2/123
2/3 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Measuring and monitoring relays
Benefits and advantages
– Only 22.5 mm wide housing
– Output contacts: 1 c/o
contact or 1 n/o contact
– One supply voltage range
– One monitoring function
– Cost-efficient solution for
OEM applications
– Preset monitoring ranges
– Only 22.5 mm wide housing
– Output contacts: 1 or 2 c/o (SPDT) con-
tacts
– One supply voltage range or supplied by
measuring circuit
– Setting and operation via front-face
operating controls
– Adjustment of threshold values and
switching hysteresis via direct reading
scale
– Integrated and snap-fitted front-face
marker
– Snap-on housing: The relays can be
placed on a DIN rail tool-free - just snap
it on or remove it tool-free
– Sealable transparent cover (accessory)
– 45 mm wide housing
– Output contacts: 2 c/o (SPDT) contacts
– Continuous voltage range (24-240 V AC/DC)
or single-supply
– Setting and operation via front-face operat-
ing controls
– Adjustment of threshold values and switch-
ing hysteresis via direct reading scale
– Adjustable time delays
– Integrated and snap-fitted front-face marker
label
– Sealable transparent cover (accessory)
CM-N range: Multifunctional CM-S range: Universal and multifunctional
CM-E range: Economy
ABB‘s measuring and monitoring relays in a new housing
Easy Connect TechnologyNew options:Additionally to the existing well established screw connections
a new innovative connection technology can be offered: Easy
Connect Technology with push-in terminals.
Tool-free wiring:The push-in terminals can be wired with rigid or fine stranded
wires with wire end ferrules totally tool-free. The connection
direction is exactly the same as the screw version.
Higher utility class:The Easy Connect Technology provides excellent vibration
resistance with gas tight push-in terminals – the right solution
for harsh environment.
Extended featuresFlammability:The plastic housing material used meets the requirements for
the highest flammability class. (UL94 V-0 rated)
Look and feel:The new housing fits perfectly with ABB’s control products
offer.
Benefits at a glance
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/4
2
Double-chamber cage connection terminalsDouble-chamber cage connection terminals provide connec-
tion of wires up to 2 x 0.5-2.5 mm² (2 x 20-14 AWG) rigid or
fine-strand, with or without wire end ferrules. Potential dis-
tribution does not require additional terminals. The extended
type designators for products with double-chamber cage con-
nection terminals are indicated by a S following the extended
type designator e.g. CM-xxS.xxS.
LED‘s for status indicationAll actual operational states are displayed by front-face LEDs,
thus simplifying commissioning and troubleshooting.
Integrated marker labelIntegrated marker labels allow the product to be marked
quickly and simply. No additional marker labels are required.
Sealable transparent coverProtection against unauthorized changes of time and thresh-
old values. Available as an accessory.
Snap-On housingTool-free DIN rail installation and deinstallation of the monitor-
ing relay.
Measuring and monitoring relays
Benefits and advantages
2C
DC
25
3 0
11
F0
00
31
SV
C 1
10
00
0 F
05
06
2C
DC
25
3 0
26
F0
01
12
CD
C 2
53
02
5 F
00
11
2C
DC
25
2 0
06
F0
01
2
2C
DC
25
5 0
06
S0
01
1
2C
DC
25
3 0
07
F0
01
2
Higher utility classThe Easy Connect Technology provides excellent vibration
resistance with gas tight push-in terminals – the right solu-
tion for harsh environment. Selected products of the elec-
tronic timers and measuring and monitoring relays comply
to the latest rail standards NF F 16-101/102, EN 45545,
EN 50155 and more standards which are relevant for rail-
way applications. Find more inforamtion in the rail brochure
2CDC110084B0201.
SafetyThe „real distance“ is hidden.
The clearance and the creepage distances of our products
exceed international standards and substantially increase the
safety of our products.
Easy Connect TechnologyTool-free wiring and excellent vibration resistance. Push-in
terminals provide connection of wires up to 2 x 0.5 - 1.5 mm²
(2 x 20 -16 AWG), rigid or fine-strand with or without wire
end ferrules. The extended type designators for products with
push-in terminals are indicated by a P following the extended
type designator e.g. CM-xxS.xxP.
1
1
3
3
4
4
5 7
7
5
6 8
6
2
2
8
2C
DC
25
3 0
13
F0
01
3
8
2/5 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Measuring and monitoring relays
Monitoring features and application ranges
v
Single-phase current and voltage monitoring – Over- or undercurrent monitoring CM-SRS and CM-SRS.M
– Over- and undercurrent monitoring CM-SFS
– Over- or undervoltage monitoring CM-ESS and CM-ESS.M
– Over- and undervoltage monitoring CM-EFS
Three-phase monitoring – Phase failure CM-PBE
– Over- and undervoltage CM-PVE
– Phase sequence and phase failure CM-PFE and CM-PFS
– Phase sequence and phase failure, over- and undervoltage
CM-PSS.xx and CM-PVS.xx
– Phase sequence and phase failure, unbalance CM-PAS.xx
– Phase sequence and phase failure, unbalance, over- and
undervoltage CM-MPS.xx and CM-MPN.xx
– Over- and undervoltage, over- and underfrequency CM-UFS.1
Motor load monitoringCM-LWN monitoring relays load states of single- and three-
phase asynchronous motors.
Current monitoring – Monitoring of motor current consumption
– Monitoring of lighting installations and heating circuits
– Monitoring of hoisting gear and transportation equipment
overload
– Monitoring of locking devices, electromechanical brake
gear and locked rotor
Voltage monitoring – Speed monitoring of DC motors
– Monitoring of battery voltages and other supply networks
– Monitoring of upper and lower voltage threshold values
Three-phase voltage monitoring – Voltage monitoring of mobile three-phase equipment
– Protection of personnel and installations against phase
reversal
– Monitoring of the supply voltage to machines and installa-
tions
– Protection of equipment against damage caused by un-
stable supply voltage
– Switching to emergency or auxiliary supply
– Protection of motors against damage caused by unbal-
anced phase voltages and phase loss
– Automatic connection & disconnection of decentralised
power stations to the grid
Insulation monitoring – For electrically isolated AC systems: CM-IWS.2
– For electrically isolated AC, DC and mixed AC/DC systems:
CM-IWS.1, CM-IWN.1 and especially for solar applications:
� 500 μF: CM-IWN.4
� 1000 μF: CM.IWN.5
� 2000 μF: CM-IWN.6
– Monitoring of electrically isolated supply mains for insula-
tion resistance failure
– Detection of initial faults
– Protection against earth faults
– Detection of V-belt breaking
– Motor protection against overload
– Monitoring of filters for clogging
– Protection of pumps against dry running
– Detection of high pressure in conduit systems
– Monitoring for dulling blades in sawing and cutting machines ϑ
Thermistor motor protectionCM-MSS provide full protection of motors with integrated
PTC resistor sensors.
Grid feeding monitoring relaysThe CM-UFx range monitors all voltage and frequency pa-
rameters in a grid and ensures the safe feeding of decentral
produced eletrical energy into the grid.
– Monitoring of the voltage with up to 2 thresholds for over-
and undervoltage
– Monitoring of the frequency with up to 2
thresholds for over- and underfrequency
– Optional ROCOF (rate of change of frequency)
and vector shift
– Acc. to national grid feeding standards such
as CEI 0-21, VDE AR-N 4105 etc.
– Protection of motors against thermal over-
load, e. g. caused by insufficient cooling,
heavy load starting conditions, undersized
motors, etc.
V,f
L1L2L3N
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/6
2
– Protection of pumps against dry running
– Protection against container overflow
– Control of liquid levels
– Detection of leaks
– Control of mixing ratios
Liquid level monitoring and controlCM-ENE, CM-ENS and CM-ENN for control and regulation of
liquid levels and ratios of mixtures of conductive fluids.
ϑ
Temperature monitoring
– Motor and system protection
– Control panel temperature monitoring
– Frost monitoring
– Temperature limits for process variables, e.g. in the
packing or electroplating industry
– Control of systems and machines like heating,
air-conditioning and ventilation systems, solar collectors,
heat pumps or hot water supply systems
– Monitoring of servomotors with KTY sensors
– Bearing and gear oil monitoring
– Coolant monitoring
Acquisition, messaging and regulation of temperatures of
solid, liquid and gaseous media in processes and machines
– with CM-TCS via PT100 sensor
– with C512 and C513 with PT100, PT1000
KTY83, KTY84 or NTC sensors
Measuring and monitoring relays
Monitoring features and application ranges
2/7 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Measuring and monitoring relays
Approvals and marks
� existing
� pending
Current and voltage monitoring, single-phase Three-phase monitoring
Approvals CM
-SR
S.1
xS/P
CM
-SR
S.2
xS
CM
.SR
S.M
S/P
CM
-SFS
.2S
/P
CM
-ES
S.1
xS/P
CM
-ES
S.2
xS
CM
-ES
S.M
S/P
CM
- E
FS
.2S
/P
CM
-PB
E
CM
-PV
E
CM
-PF
E
CM
-PFS
.S/P
CM
-PS
S.x
1S
/P
CM
-PV
S.x
1S
/P
CM
-PV
S.8
1S
/P
CM
-PA
S.x
1S
/P
CM
-MP
S.x
1S
/P
CM
-MP
S.x
3S
/P
CM
-MP
N.5
2S
/P
CM
-MP
N.6
2S
/P
CM
-MP
N.7
2S
/P
A UL 508, CAN/CSA C22.2 No.14 � � � � � � � � � � � � � � � � � � � �C GL � � � � � � � � � � � � � � � � � �R EAC � � � � � � � � � � � � � � � � � � � � �K CB scheme � � � � � � � � � � � � � � � � � � � � �E CCC � � � � � � � � � � � � � � � � � � � � �L RMRS � � � � � � � � � � � � � � � � � � � �
Rail applications 1) � � � � � � � � �Marks
a CE � � � � � � � � � � � � � � � � � � � �b RCM � � � � � � � � � � � � � � � � � � � �
� existing � pending
Insulation monitoring relays for ungrounded supply mains
Motor load monitoring
Tempera-ture monitoring
Grid feeding monitoring relays
Approvals CM
-IW
S.2
S/P
CM
-IW
S.1
S/P
CM
-IW
N.1
S/P
CM
-IW
N.4
,5,6
.S/P
CM
-IV
N.S
/P
CM
-LW
N
CM
-TC
S.x
S/P
C51
2
C51
3
CM
-UF
D.M
22
CM
-UF
D.M
31
CM
-UF
D.M
33
A UL 508, CAN/CSA C22.2 No.14 � � � � � � � � � �C GL � � � � � �R EAC � � � � � � �K CB scheme � � � � � � �E CCC � � � � � � �L RMRS � � � � �
Rail applications 1) � � �CEI 0-21 �G59/3 LV + G83/2, G59/3 HV �VDE-AR-N 4105 „Erzeugungsanlagen am Niederspannungsnetz“
�
BDEW „Erzeugungsanlagen am Mittelspannungsnetz“
�Marks
a CE � � � � � � � � � � � �b RCM � � � � � � �
1) Applicable in rail application following the latest standards for rail applications: NF F 16-101/102 (I2/F2 classified), EN 45545 (Hazard Level 3), DIN 5510, EN 50155,
IEC 60571. Further information is available in our rail segment brochure 2CDC110084B0201.
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/8
2
Measuring and monitoring relays
Approvals and marks
� existing � pending Thermistor motor protection Liquid level
monitoring
Approvals CM
-MS
E
CM
-MS
S.x
1
CM
-MS
S.1
2
CM
-MS
S.1
3
CM
-MS
S.2
2
CM
-MS
S.2
3
CM
-MS
S.3
2
CM
-MS
S.3
3
CM
-EN
E M
IN
CM
-EN
E M
AX
CM
-EN
S
CM
-EN
S U
P/..
.
CM
-EN
N
A UL 508, CAN/CSA C22.2 No.14 � � � � � � � � � � � � �C GL � � � � � � � �1) �R EAC � � � � � � � � � � � � �I II (2) G D, PTB 02 ATEX 3080
K CB scheme � � � � � � � � � � � � �E CCC � � � � � � � � � � � � �L RMRS � � � � � �I ATEX � � �Marks
a CE � � � � � � � � � � � � �b RCM � � � � � � � � � � � � �
1) Version with protective separation without C approval
2/9 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Current and voltage monitoring relays, single-phase
Product group picture
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/10
2
Current and voltage monitoring relays, single-phase
Table of contents
Current and voltage monitoring relays, single-phase
Benefits and advantages 2/11
Operating controls 2/12
Selection table - Current monitoring relays 2/13
Selection table - Voltage monitoring relays 2/14
Ordering details - Current monitoring relays 2/15
Ordering details - Voltage monitoring relays 2/16
Function diagrams 2/17
Connection diagrams, DIP switches 2/20
Technical data - Current monitoring relays 2/22
Technical data - Voltage monitoring relays 2/24
2/11 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Current and voltage monitoring relays, single-phase
Benefits and advantages
Characteristics current and voltage monitoring relays – Monitoring of DC and AC currents: 3 mA to 15 A 1)
– Monitoring of DC and AC voltages from 3-600 V
– TRMS measuring principle
– One device includes 3 measuring ranges
– One device includes 4 measuring ranges: 3-30 V; 6-60 V;
30-300 V; 60-600 V
– Over- and undercurrent monitoring1)
– Over- and undervoltage monitoring1)
– ON or OFF-delay configurable1)
– Open- or closed-circuit principle configurable1)
– Threshold values for >U and/or <U adjustable1)
– Latching function configurable1)
– Thresholds for >I and/or <I adjustable1)
– Fixed hysteresis of 5 %1)
– Start-up delay Tv adjustable 0; 0.1-30 s1)
– Tripping delay Tv adjustable 0; 0.1-30 s1)
– 1 x 2 c/o contacts (common signal) or 2 x 1 c/o contact
(separate signals for >I and <I) configurable 1)
– 1 x 2 c/o contacts (common signal) or 2 x 1 c/o contact
(separate signals for >U and <U) configurable1)
– 22.5 mm width
– 3 LEDs for the indication of operational states
– Approvals / Marks
A C R K E L 2)
/ a b
1) depending on device2) Applicable in rail application following the latest standards for rail applications:
NF F 16-101/102 (I2/F2 classified), EN 45545 (Hazard Level 3), DIN 5510, EN 50155, IEC 60571.
Further information is available in our rail segment brochure 2CDC110084B0201.
Current monitoring, single-phaseThe ABB current monitoring relays CM-SRS.xx
reliably monitor the occurence of currents that
exceed or fall below the selected threshold value.
The functions overcurrent or undercurrent monitor-
ing can be preselected. Single- and multifunction
devices for the monitoring of direct or alternating
currents from 3 mA to 15 A are available.
Current window monitoring (Imin, Imax)The window monitoring relay CM-SFS.2x is avail-
able if the application requires the simultaneous
monitoring of over- and undercurrents.
Voltage monitoring, single-phaseThe ABB voltage monitoring relays CM-SRS.xx
are used to monitor direct and alternating voltages
within a range of 3-600 V. Over- or undervoltage
detection can be preselected.
Voltage window monitoring (Umin, Umax)For the simultaneous detection of over- and under-
voltages, the window monitoring relay CM-EFS.2
can be used.
2C
DC
25
1 0
56
V0
01
1
2C
DC
25
1 0
59
V0
01
1
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/12
2
Current and voltage monitoring relays, single-phase
Operating controls
2C
DC
25
3 0
18
F0
01
32
CD
C 2
53
01
4 F
00
13
4
1
2
3
5
1 Adjustment of the threshold value >I for overcurrent
2 Adjustment of the threshold value <I for undercurrent
3 Indication of operational states U/T: green LED – control supply voltage/timing
R: yellow LED – relay status
I: red LED – over- / undercurrent
4 Adjustment of the tripping delay TV
5 Adjustment of the start-up delay TS
6 DIP switches (see DIP switch functions on page 2/20) A ON-delay
B OFF-delay
g Closed-circuit principle
h Open-circuit principle
f Latching function activated
e Latching function not activated
i 2x1 c/o (SPDT) contact
j 1x2 c/o (SPDT) contacts
1 Adjustment of the threshold value >U for overvoltage
2 Adjustment of the threshold value <U for undervoltage
3 Indication of operational states U/T: green LED – control supply voltage/timing
R: yellow LED – relay status
U: red LED – over- / undervoltage
4 Adjustment of the tripping delay TV
5 Adjustment of the measuring range
6 DIP switches (see DIP switch functions on page 2/20) A ON-delay
B OFF-delay
g Closed-circuit principle
h Open-circuit principle
f Latching function activated
e Latching function not activated
i 2x1 c/o (SPDT) contact
j 1x2 c/o (SPDT) contacts
4
1
2
3
5
Current monitoring relays
Voltage monitoring relays
2/13 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Current and voltage monitoring relays, single-phase
Selection table - Current monitoring relays
Ord
er n
um
ber
1S
VR
73
08
40
R0
20
0
1S
VR
74
08
40
R0
20
0
1S
VR
73
08
41R
02
00
1S
VR
74
08
41R
02
00
1S
VR
73
08
41R
12
00
1S
VR
74
08
41R
12
00
1S
VR
73
08
40
R0
30
0
1S
VR
73
08
41R
03
00
1S
VR
73
08
41R
13
00
1S
VR
73
08
40
R0
40
0
1S
VR
74
08
40
R0
40
0
1S
VR
73
08
41R
04
00
1S
VR
74
08
41R
04
00
1S
VR
73
08
41R
14
00
1S
VR
74
08
41R
14
00
1S
VR
73
08
40
R0
50
0
1S
VR
73
08
41R
05
00
1S
VR
73
08
41R
15
00
1S
VR
73
08
40
R0
60
0
1S
VR
74
08
40
R0
60
0
1S
VR
73
08
40
R0
70
0
1S
VR
73
07
60
R0
40
0
1S
VR
74
07
60
R0
40
0
1S
VR
73
07
60
R0
50
0
Typ
e
CM
-SR
S.1
1S
CM
-SR
S.1
1P
CM
-SR
S.1
1S
CM
-SR
S.1
1P
CM
-SR
S.1
1S
CM
-SR
S.1
1P
CM
-SR
S.1
2S
CM
-SR
S.2
1S
CM
-SR
S.2
1P
CM
-SR
S.2
1S
CM
-SR
S.2
1P
CM
-SR
S.2
1S
CM
-SR
S.2
1P
CM
-SR
S.2
2S
CM
-SR
S.M
1S
CM
-SR
S.M
1P
CM
-SR
S.M
2S
CM
-SF
S.2
1S
CM
-SF
S.2
1P
CM
-SF
S.2
2S
Rated control supply voltage Us
24 - 240 V AC/DC � � � � � � � � � � � �
110 - 130 V AC � � � � � �
220 - 240 V AC � � � � � �
Measuring ranges AC/DC
3 - 30 mA � � � � � � � � � � � � � � � �
10 - 100 mA � � � � � � � � � � � � � � � �
0.1 - 1 A � � � � � � � � � � � � � � � �
0.3 - 1.5 A � � � � � � � �
1 - 5 A � � � � � � � �
3 - 15 A � � � � � � � �
Monitoring function
Over- or undercurrent � � � � � � � � � � � � � � � � � � � � �
Windows current monitoring � � �
Latching sel sel sel sel sel sel
Open circuit or closed circuit principle sel sel sel sel sel sel
Timing functions for tripping delay
ON delay, 0 or 0. 1 - 30 s adj adj adj adj adj adj adj adj adj adj adj adj
ON or OFF delay sel sel sel
Output
c/o contact 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
Connection type
Push-in terminals � � � � � � � �
Double-chamber cage connection terminals
� � � � � � � � � � � � � � � �
adj: adjustable
sel: selectable
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/14
2
Current and voltage monitoring relays, single-phase
Selection table - Voltage monitoring relays
Ord
er n
um
ber
1S
VR
73
08
30
R0
30
0
1S
VR
74
08
30
R0
30
0
1S
VR
73
08
31R
03
00
1S
VR
74
08
31R
03
00
1S
VR
73
08
31R
13
00
1S
VR
74
08
31R
13
00
1S
VR
73
08
30
R0
40
0
1S
VR
74
08
30
R0
40
0
1S
VR
73
08
31R
04
00
1S
VR
74
08
31R
04
00
1S
VR
73
08
31R
14
00
1S
VR
74
08
31R
14
00
1S
VR
73
08
30
R0
50
0
1S
VR
74
08
30
R0
50
0
1S
VR
73
07
50
R0
40
0
1S
VR
74
07
50
R0
40
0
Typ
e
CM
-ES
S.1
S
CM
-ES
S.1
P
CM
-ES
S.1
S
CM
-ES
S.1
P
CM
-ES
S.1
S
CM
-ES
S.1
P
CM
-ES
S.2
S
CM
-ES
S.2
P
CM
-ES
S.2
S
CM
-ES
S.2
P
CM
-ES
S.2
S
CM
-ES
S.2
P
CM
-ES
S.M
S
CM
-ES
S.M
P
CM
-EF
S.2
S
CM
-EF
S.2
P
Rated control supply voltage Us
24 - 240 V AC/DC � � � � � � � �
110 - 130 V AC � � � �
220 - 240 V AC � � � �
Measuring ranges AC/DC
3 - 30 V � � � � � � � � � � � � � � � �
6 - 60 V � � � � � � � � � � � � � � � �
30 - 300 V � � � � � � � � � � � � � � � �
60 - 600 V � � � � � � � � � � � � � � � �
Monitoring function
Over- or undervoltage � � � � � � � � � � � � � �
Windows voltage monitoring � �
Latching sel sel sel sel
Open circuit or closed circuit principle sel sel sel sel
Timing functions for tripping delay
ON delay, 0 or 0.1 - 30 s adj adj adj adj adj adj adj adj
ON or OFF delay sel sel
Output
c/o contact 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2
Connection type
Push-in terminals � � � � � � � �
Double-chamber cage connection terminals
� � � � � � � �
adj: adjustable
sel: selectable
2/15 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Current and voltage monitoring relays, single-phase
Ordering details - Current monitoring relays
Description
The CM range current monitoring relays protect single-phase mains (DC or AC) from over- and
undercurrent from 3 mA to 15 A. Two different terminal versions are available. You can choose
between the proven screw connection technology (double-chamber cage connecting termi-
nals) and the completely tool-free Easy Connect Technology (push-in terminals).
Ordering detailsRated control supply voltage
Function Tripping delay TV
Measuring range
Type Order code Price
1 pce
Weight (1 pce)kg (lb)
24-240 V AC/DC
ba
without3-30 mA, 10-100 mA, 0.1-1 A
CM-SRS.11S
1SVR730840R0200 0.145 (0.320)
110-130 V AC 1SVR730841R0200 0.161 (0.355)
220-240 V AC 1SVR730841R1200 0.161 (0.355)
24-240 V AC/DC
CM-SRS.11P
1SVR740840R0200 0.137 (0.302)
110-130 V AC 1SVR740841R0200 0.153 (0.337)
220-240 V AC 1SVR740841R1200 0.153 (0.337)
24-240 V AC/DC
ba
without0.3-1.5 A, 1-5 A, 3-15 A
CM-SRS.12S
1SVR730840R0300 0.137 (0.302)
110-130 V AC 1SVR730841R0300 0.168 (0.370)
220-240 V AC 1SVR730841R1300 0.168 (0.370)
24-240 V AC/DC
ba
adjustable 0 or 0.1-30 s
3-30 mA, 10-100 mA, 0.1-1 A
CM-SRS.21S
1SVR730840R0400 0.152 (0.335)
110-130 V AC 1SVR730841R0400 0.179 (0.395)
220-240 V AC 1SVR730841R1400 0.179 (0.395)
24-240 V AC/DC
CM-SRS.21P
1SVR740840R0400 0.141 (0.311)
110-130 V AC 1SVR740841R0400 0.168 (0.370)
220-240 V AC 1SVR740841R1400 0.168 (0.370)
24-240 V AC/DC
ba
adjustable 0 or 0.1-30 s
0.3-1.5 A, 1-5 A, 3-15 A
CM-SRS.22S
1SVR730840R0500 0.144 (0.399)
110-130 V AC 1SVR730841R0500 0.181 (0.399)
220-240 V AC 1SVR730841R1500 0.181 (0.399)
24-240 V AC/DC beaf
adjustable 0 or 0.1-30 s
3-30 mA, 10-100 mA, 0.1-1 A
CM-SRS.M1S 1SVR730840R0600 0.153 (0.337)
CM-SRS.M1P 1SVR740840R0600 0.142 (0.313)
24-240 V AC/DCadjustable 0 or 0.1-30 s
0.3-1.5 A, 1-5 A, 3-15 A
CM-SRS.M2S 1SVR730840R0700 0.155 (0.342)
24-240 V AC/DCbeafji
adjustable 0 or 0.1-30 s
3-30 mA, 10-100 mA, 0.1-1 A
CM-SFS.21S 1SVR730760R0400 0.150 (0.331)
CM-SFS.21P 1SVR740760R0400 0.139 (0.306)
24-240 V AC/DCadjustable 0 or 0.1-30 s
0.3-1.5 A, 1-5 A, 3-15 A
CM-SFS.22S 1SVR730760R0500 0.158 (0.348)
2C
DC
25
1 0
54
V0
01
12
CD
C 2
51
05
6 V
00
11
CM-SRS.22S
CM-SFS.22P
b Overcurrent monitoring
a Undercurrent monitoring
e Without latching
f With latching
j 1x2 c/o (SPDT) contacts
i 2x1 c/o (SPDT) contact
S: screw connection
P: push-in / easy connect
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/16
2
Current and voltage monitoring relays, single-phase
Ordering details - Voltage monitoring relays
Description
The CM range voltage monitoring relays provide reliable monitoring of voltages as well as de-
tection of phase loss in single-phase mains.
All devices are available with two different terminal versions. You can choose between the
proven screw connection technology (double-chamber cage connecting terminals) and the
completely tool-free Easy Connect Technology (push-in terminals).
Ordering detailsRated control supply voltage
Function Tripping delay TV
Measur-ing range AC/DC
Type Order code Price
1 pce
Weight (1 pce)kg (lb)
24-240 V AC/DC
d c
without
3-30 V, 6-60 V, 30-300 V, 60-600 V
CM-ESS.1S
1SVR730830R0300 0.135 (0.298)
110-130 V AC 1SVR730831R0300 0.164 (0.362)
220-240 V AC 1SVR730831R1300 0.164 (0.362)
24-240 V AC/DC
CM-ESS.1P
1SVR740830R0300 0.126 (0.278)
110-130 V AC 1SVR740831R0300 0.155 (0.342)
220-240 V AC 1SVR740831R1300 0.155 (0.342)
24-240 V AC/DC
d c
adjustable 0 or 0.1-30 s
3-30 V, 6-60 V, 30-300 V, 60-600 V
CM-ESS.2S
1SVR730830R0400 0.153 (0.337)
110-130 V AC 1SVR730831R0400 0.181 (0.399)
220-240 V AC 1SVR730831R1400 0.181 (0.399)
24-240 V AC/DC
CM-ESS.2P
1SVR740830R0400 0.142 (0.313)
110-130 V AC 1SVR740831R0400 0.170 (0.375)
220-240 V AC 1SVR740831R1400 0.170 (0.375)
24-240 V AC/DC
de ce df cf
adjustable 0 or 0.1-30 s
3-30 V, 6-60 V, 30-300 V, 60-600 V
CM-ESS.MS 1SVR730830R0500 0.154 (0.340)
CM-ESS.MP 1SVR740830R0500 0.143 (0.320)
24-240 V AC/DC
beafji
adjustable 0 or 0.1-30 s
3-30 V, 6-60 V, 30-300 V, 60-600 V
CM-EFS.2S 1SVR730750R0400 0.157 (0.346)
CM-EFS.2P 1SVR740750R0400 0.146 (0.322)
2C
DC
25
1 0
60
V0
01
12
CD
C 2
51
05
9 V
00
11
CM-ESS.MP
CM-EFS.2
b Overcurrent monitoring
a Undercurrent monitoring
e Without latching
f With latching
j 1x2 c/o (SPDT) contacts
i 2x1 c/o (SPDT) contact
S: screw connection
P: push-in / easy connect
2/17 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Function diagrams - CM-SRS.1Overcurrent monitoring b
Undercurrent monitoring a
Function diagrams - CM-SRS.2Overcurrent monitoring b
Undercurrent monitoring a
A1-A2
11-14 (15-18) 11-12 (15-16)
Threshold
Hysteresis
Measured value
green LED
red LED
yellow LED
2CD
C 2
52 2
08 F
0205
A1-A2
11-14 (15-18) 11-12 (15-16)
Threshold
Hysteresis
Measured value
green LED
red LED
yellow LED
2CD
C 2
52 2
09 F
0205
A1-A2
11-14 (15-18) 11-12 (15-16)
21-24 (25-28) 21-22 (25-26)
Threshold
Hysteresis
Measured value
green LED
red LED
yellow LED
2CD
C 2
52 2
10 F
0205
TV < TV
A1-A2
11-14 (15-18) 11-12 (15-16)
21-24 (25-28) 21-22 (25-26)
Threshold
Hysteresis
Measured value
green LED
red LED
yellow LED
2CD
C 2
52 2
11 F
0205
TV < TV
Function diagrams - CM-SRS.MOvercurrent monitoring b without latching e
Overcurrent monitoring b with latching f
Undercurrent monitoring a without latching e
Undercurrent monitoring b with latching f
A1-A2
11-14 (15-18) 11-12 (15-16)
21-24 (25-28) 21-22 (25-26)
11-14 (15-18) 11-12 (15-16)
21-24 (25-28) 21-22 (25-26)
closed
open
Threshold
Hysteresis
Measured value
green LED
red LED
yellow LED
2CD
C 2
52 2
12 F
0205
TS
green LED
red LED
yellow LED
Open-circuit principle
Closed-circuit principle
TV < TV
A1-A2
11-14 (15-18) 11-12 (15-16)
21-24 (25-28) 21-22 (25-26)
11-14 (15-18) 11-12 (15-16)
21-24 (25-28) 21-22 (25-26)
open
closed
Threshold
Hysteresis
Measured value
green LED
red LED
yellow LED
2CD
C 2
52 2
14 F
0205
TS
green LED
red LED
yellow LED
Open-circuit principle
Closed-circuit principle
TV < TV TS
Reset
A1-A2
11-14 (15-18) 11-12 (15-16)
21-24 (25-28) 21-22 (25-26)
11-14 (15-18) 11-12 (15-16)
21-24 (25-28) 21-22 (25-26)
closed
open
Threshold
Hysteresis
Measured value
green LED
red LED
yellow LED
2CD
C 2
52 2
13 F
0205
TS
green LED
red LED
yellow LED
Open-circuit principle
Closed-circuit principle
TV < TV
A1-A2
11-14 (15-18) 11-12 (15-16)
21-24 (25-28) 21-22 (25-26)
11-14 (15-18) 11-12 (15-16)
21-24 (25-28) 21-22 (25-26)
closed
open
Threshold
Hysteresis
Measured value
green LED
red LED
yellow LED
2CD
C 2
52 2
15 F
0205
TS
green LED
red LED
yellow LED
Open-circuit principle
Closed-circuit principle
TV < TV TS
Reset
If the measured value exceeds resp. drops below the adjusted threshold value, the output relay(s) energize(s): on the CM-SRS.1
immediately, on the CM-SRS.2 after the set tripping delay TV. If the measured value exceeds resp. drops below the threshold
value plus resp. minus the adjusted hysteresis, the output relay(s) de-energize(s). The hysteresis is adjustable within a range of
3-30 % of the threshold value.
If the measured value exceeds resp. drops below the adjusted threshold value before the set start-up delay TS is complete, the
output relays do not change their actual state. If the measured value exceeds resp. drops below the adjusted threshold value
when TS is complete, the tripping delay T
V starts. If T
V is complete and the measured value is still exceeding resp. below the
threshold value plus resp. minus the set hysteresis, the output relays energize h / de-energize g.
If the measured value exceeds resp. drops below the threshold value minus resp. plus the set hysteresis and the latching func-
tion is not activated e, the output relays de-energize h / energize g. With activated latching function f the output relays
remain energized h and de-energize only, when the supply voltage is interrupted / the output relays remain de-energized g
and energize only, when the supply voltage is switched off and then again switched on = Reset.
The hysteresis is adjustable within a range of 3-30 % of the threshold value.
Current and voltage monitoring relays, single-phase
Function diagrams
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/18
2
Current and voltage monitoring relays, single-phase
Function diagrams
Function diagrams - CM-ESS.1Overvoltage monitoring d
Undervoltage monitoring c
Function diagrams - CM-ESS.2Overvoltage monitoring d
Undervoltage monitoring c
A1-A2
11-14 (15-18) 11-12 (15-16)
Threshold
Hysteresis
Measured value
green LED
red LED
yellow LED
2CD
C 2
52 2
08 F
0205
A1-A2
11-14 (15-18) 11-12 (15-16)
Threshold
Hysteresis
Measured value
green LED
red LED
yellow LED
2CD
C 2
52 2
09 F
0205
A1-A2
11-14 (15-18) 11-12 (15-16)
21-24 (25-28) 21-22 (25-26)
Threshold
Hysteresis
Measured value
green LED
red LED
yellow LED
2CD
C 2
52 2
10 F
0205
TV < TV
A1-A2
11-14 (15-18) 11-12 (15-16)
21-24 (25-28) 21-22 (25-26)
Threshold
Hysteresis
Measured value
green LED
red LED
yellow LED
2CD
C 2
52 2
11 F
0205
TV < TV
OFF-delayed B current window monitoring with parallel switching c/o contacts j:If the measured value exceeds resp. drops below the adjusted
threshold value when the set start-up delay TS
is complete,
the output relays energize h / de-energize g, when B is
configured, and remain in this position during the set tripping
delay TV. If the measured value exceeds resp. drops below the
threshold value plus resp. minus the fixed hysteresis (5%) and
the latching function is not activated e, the tripping delay TV
starts. After completion of TV, the output relays de-energize
h / energize g, provided that the latching function is not
activated e. With activated latching function f the out-
put relays remain energized h and de-energize only, when
the supply voltage is interrupted / the output relays remain
de-energized g and energize only, when the supply voltage
is switched off and then again switched on = Reset. When
i is adjusted on the device, the functionality is equivalent
to the one described above. There is only to consider that in
this case, instead of both output relays, only one output relay
each will be switched.
“>I“ = 1115
-1216
/1418
; “<I“ = 2125
-2226
/2428
Function diagrams - CM-SFS.2Current window monitoring 1x2 c/o contact j ON-delayed A without latching f
Current window monitoring 1x2 c/o contact j OFF-delayed B without latching e
Further function diagrams see data sheet.
A1-A2
11-14 (15-18) 11-12 (15-16)
21-24 (25-28) 21-22 (25-26)
11-14 (15-18) 11-12 (15-16)
21-24 (25-28) 21-22 (25-26)
open
closed
Thresholdmax
Hysteresis
green LED
red LED
yellow LED
2CD
C 2
52 2
16 F
0205
TS
green LED
red LED
yellow LED
Open-circuit principle
Closed-circuit principle
TV < TV Hysteresis
Measured value
Thresholdmin
A1-A2
11-14 (15-18) 11-12 (15-16)
21-24 (25-28) 21-22 (25-26)
11-14 (15-18) 11-12 (15-16)
21-24 (25-28) 21-22 (25-26)
open
closed
Thresholdmax
Hysteresis
green LED
red LED
yellow LED
2CD
C 2
52 2
17 F
0205
TS
green LED
red LED
yellow LED
Open-circuit principle
Closed-circuit principle
TV TV Hysteresis
Measured value
Thresholdmin
ON-delayed A current window monitoring with parallel switching c/o contacts j:If the measured value exceeds resp. drops below the adjusted
threshold value before the set start-up delay TS is complete,
the output relays do not change their actual state.
If the measured value exceeds resp. drops below the adjusted
threshold value when TS is complete, the tripping delay T
V
starts, when A is configured. If TV is complete and the mea-
sured value is still exceeding resp. below the threshold value
minus resp. plus the fixed hysteresis (5%), the output relays
energize h /de-energize g.
If the measured value exceeds resp. drops below the thresh-
old value plus resp. minus the hysteresis and the latching
function is not activated f, the output relays de-energize h
/ energize g. With activated latching function e the output
relays remain energized h and de-energize only, when the
supply voltage is interrupted / the output relays remain de-
energized g and energize only, when the supply voltage is
switched off and then again switched on = Reset.
Depending on the configuration, the voltage monitoring relays CM-ESS.1 and CM-ESS.2 can be used for over- d or undervolt-
age monitoring c in single-phase AC and/or DC systems. The voltage to be monitored (measured value) is applied to terminals
B-C. The devices work according the open-circuit principle. If the measured value exceeds resp. drops below the adjusted
threshold value, the output relay(s) energize(s): on the CM-ESS.1 immediately, on the CM-ESS.2 after the set tripping delay
TV. If the measured value exceeds resp. drops below the threshold value plus resp. minus the adjusted hysteresis, the output
relay(s) de-energize(s). The hysteresis is adjustable within a range of 3-30 % of the threshold value.
2/19 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
If the measured value exceeds resp. drops below the adjusted threshold value, the tripping delay TV starts. If T
V is complete
and the measured value is still exceeding resp. below the threshold value plus resp. minus the set hysteresis, the output relays
energize h / de-energize g.
If the measured value exceeds resp. drops below the threshold value plus resp. minus the set hysteresis and the latching func-
tion is not activated e, the output relays de-energize h / energize g. With activated latching function f the output relays
remain energized h and de-energize only, when the supply voltage is interrupted / the output relays remain de-energized g
and energize only, when the supply voltage is switched off and then again switched on = Reset. The hysteresis is adjustable
within a range of 3-30 % of the threshold value.
Function diagrams - CM-ESS.MOvervoltage monitoring d without latching e Undervoltage monitoring c without latching e
Undervoltage monitoring c without latching f
A1-A2
11-14 (15-18) 11-12 (15-16)
21-24 (25-28) 21-22 (25-26)
11-14 (15-18) 11-12 (15-16)
21-24 (25-28) 21-22 (25-26)
open
closed
Threshold
Hysteresis
Measured value
green LED
red LED
yellow LED
2CD
C 2
52 2
28 F
0205
< TV
green LED
red LED
yellow LED
Open-circuit principle
Closed-circuit principle
TV < TV
A1-A2
11-14 (15-18) 11-12 (15-16)
21-24 (25-28) 21-22 (25-26)
11-14 (15-18) 11-12 (15-16)
21-24 (25-28) 21-22 (25-26)
open
closed
Threshold
Hysteresis
Measured value
green LED
red LED
yellow LED
2CD
C 2
52 2
30 F
0205
green LED
red LED
yellow LED
Open-circuit principle
Closed-circuit principle
TV < TV
Reset
< TV
A1-A2
11-14 (15-18) 11-12 (15-16)
21-24 (25-28) 21-22 (25-26)
11-14 (15-18) 11-12 (15-16)
21-24 (25-28) 21-22 (25-26)
closed
open
Threshold
Hysteresis
Measured value
green LED
red LED
yellow LED
2CD
C 2
52 2
29 F
0205
green LED
red LED
yellow LED
Open-circuit principle
Closed-circuit principle
TV < TV < TV
A1-A2
11-14 (15-18) 11-12 (15-16)
21-24 (25-28) 21-22 (25-26)
11-14 (15-18) 11-12 (15-16)
21-24 (25-28) 21-22 (25-26)
closed
open
Threshold
Hysteresis
Measured value
green LED
red LED
yellow LED
2CD
C 2
52 2
31 F
0205
green LED
red LED
yellow LED
Open-circuit principle
Closed-circuit principle
TV < TV
Reset
< TV
ON-delayed A voltage window monitoring with parallel switching c/o contacts j:If the measured value exceeds resp. drops below the adjusted threshold value, the tripping de-
lay TV starts, when A is configured. If T
V is complete and the measured value is still exceeding
resp. below the threshold value minus resp. plus the fixed hysteresis (5%), the output relays
energize h /de-energize g.
If the measured value exceeds resp. drops below the threshold value plus resp. minus the
hysteresis and the latching function is not activated e, the output relays de-energize h /
energize g. With activated latching function e the output relays remain energized h and
de-energize only, when the supply voltage is interrupted / the output relays remain de-ener-
gized g and energize only, when the supply voltage is switched off and then again switched
on = Reset.
Voltage window monitoring 1x2 c/o contact j ON-delayed A without latching e
Voltage window monitoring 1x2 c/o contact j OFF-delayed B without latching e
Further function diagrams see data sheet.
A1-A2
11-14 (15-18) 11-12 (15-16)
21-24 (25-28) 21-22 (25-26)
11-14 (15-18) 11-12 (15-16)
21-24 (25-28) 21-22 (25-26)
open
closed
Thresholdmax
Hysteresis
green LED
red LED
yellow LED
2CD
C 2
52 2
32 F
0205
green LED
red LED
yellow LED
Open-circuit principle
Closed-circuit principle
TV < TV Hysteresis
Measured value
Thresholdmin
< TV
A1-A2
11-14 (15-18) 11-12 (15-16)
21-24 (25-28) 21-22 (25-26)
11-14 (15-18) 11-12 (15-16)
21-24 (25-28) 21-22 (25-26)
closed
open
Thresholdmax
Hysteresis
green LED
red LED
yellow LED
2CD
C 2
52 2
33 F
0205
green LED
red LED
yellow LED
Open-circuit principle
Closed-circuit principle
TV TV Hysteresis
Measured value
Thresholdmin
Current and voltage monitoring relays, single-phase
Function diagrams
OFF-delayed B voltage window monitoring with parallel switching c/o contacts j:If the measured value exceeds resp. drops below the adjusted threshold value, the output
relays energize h / de-energize g, when B is configured, and remain in this position during
the set tripping delay TV.
If the measured value exceeds resp. drops below the threshold value plus resp. minus the
fixed hysteresis (5%) and the latching function is not activated e, the tripping delay TV starts.
After completion of TV, the output relays de-energize h / energize g, provided that the latch-
ing function is not activated e. With activated latching function e the output relays remain
energized h and de-energize only, when the supply voltage is interrupted / the output relays
remain de-energized g and energize only, when the supply voltage is switched off and then
again switched on = Reset.
When i is adjusted on the device, the functionality is equivalent to the one described above.
There is only to consider that in this case, instead of both output relays, only one output relay
each will be switched.
“>U“ = 1115
-1216
/1418
; “<U“ = 2125
-2226
/2428
Overvoltage monitoring d with latching f
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/20
2
A1 A2
A1 1115
B1 B2 B3
A2
1115
1216 1418
1418 1216
C
B1 B2 B3
C
2C
DC
25
2 2
04
F0
00
5
Connection diagram CM-SRS.1, CM-SRS.2
A1 A2
2125
2226 2428
A1 1115 2125
B1 B2 B3
2428 2226 A2
1115
1216 1418
1418 1216 C
B1 B2 B3
C
2C
DC
25
2 2
05
F0
00
5
A1 A2
2125
2226 2428
A1 1115 2125
B1 B2 B3
2428 2226 A2
1115
1216 1418
1418 1216 C
B1 B2 B3
C
2C
DC
25
2 2
05
F0
00
5
Connection diagram CM-SRS.M
A1 A2
2125
2226 2428
A1 1115 2125
B1 B2 B3
2428 2226 A2
1115
1216 1418
1418 1216 C
B1 B2 B3
C
2C
DC
25
2 2
05
F0
00
5
Connection diagram CM-SFS.2
2CD
C 2
52 2
72 F
0005
DIP switch functions CM-SRS.1, CM-SRS.2
1 ONOFF
Undercurrent monitoringOvercurrent monitoring
OFF = Default
closed
open
Position 4 123
ON
OFF
I
I
2CD
C 2
52 2
73 F
0005
DIP switch functions CM-SRS.M
closed
open
2x1 c/o
1x2 c/o
Position 4 123
ON
OFF
2CD
C 2
52 2
74 F
0005
DIP switch function CM-SFS.2
closed
open V
V
Position 4 123
ON
OFF
2CD
C 2
52 2
76 F
0005
DIP switch functions CM-ESS.M
A1 A2
2125
2226 2428
A1 1115 2125
B
2428 2226 A2
1115
1216 1418
1418 1216 C
B
C
2C
DC
25
2 2
07
F0
00
5
Connection diagram CM-ESS.M
Current and voltage monitoring relays, single-phase
Connection diagrams, DIP switches
A1-A2 Control supply voltage
B1-C Measuring range 1: 3-30 mA or 0.3-1.5 A
B2-C Measuring range 2: 10-100 mA or 1-5 A
B3-C Measuring range 3: 0.1-1 A or 3-15 A
1115
-1216
/1418
2125
-2226
/2428
Output contacts - open-circuit principle
A1-A2 Control supply voltage
B1-C Measuring range 1: 3-30 mA or 0.3-1.5 A
B2-C Measuring range 2: 10-100 mA or 1-5 A
B3-C Measuring range 3: 0.1-1 A or 3-15 A
1115
-1216
/1418
2125
-2226
/2428
Output contacts - open- or closed circuit principle
A1-A2 Control supply voltage
B1-C Measuring range 1: 3-30 mA or 0.3-1.5 A
B2-C Measuring range 2: 10-100 mA or 1-5 A
B3-C Measuring range 3: 0.1-1 A or 3-15 A
1115
-1216
/1418
2125
-2226
/2428
Output contacts - open- or closed circuit principle
A1-A2 Control supply voltage
B-C Measuring ranges AC/DC:3-30 V; 6-60 V30-300 V; 60-600 V
1115
-1216
/1418
2125
-2226
/2428
Output contacts - open- or closed circuit principle
1 ONOFF
Undercurrent monitoringOvercurrent monitoring
2 ONOFF
Closed-circuit principleOpen-circuit principle
3 ONOFF
Latching function activatedLatching function not activated
OFF = Default
1 ONOFF
Undervoltage monitoringOvervoltage monitoring
2 ONOFF
Closed-circuit principleOpen-circuit principle
3 ONOFF
Latching function activatedLatching function not activated
OFF = Default
1 ONOFF
OFF-delayON-delay
2 ONOFF
Closed-circuit principleOpen-circuit principle
3 ONOFF
Latching function activatedLatching function not activated
4 ONOFF
2x1 c/o contact1x2 c/o contacts
OFF = Default
2/21 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
closed
open
2x1 c/o
1x2 c/o
Position 4 123
ON
OFF2C
DC
252
274
F00
05
DIP switch functions CM-EFS.2
A1 A2
2125
2226 2428
A1 1115 2125
B
2428 2226 A2
1115
1216 1418
1418 1216 C
B
C
2C
DC
25
2 2
07
F0
00
5
Connection diagram CM-EFS.2
A1 A2
A1 1115
B
A2
1115
1216 1418
1418 1216
C
B
C
2C
DC
25
2 2
06
F0
00
5Connection diagram CM-ESS.1, CM-ESS.2
A1 A2
2125
2226 2428
A1 1115 2125
B
2428 2226 A2
1115
1216 1418
1418 1216 C
B
C
2C
DC
25
2 2
07
F0
00
5
2CD
C 2
52 2
75 F
0005
DIP switch functions CM-ESS.1, CM-ESS.2
Current and voltage monitoring relays, single-phase
Connection diagrams, DIP switches
A1-A2 Control supply voltage
B-C Measuring ranges AC/DC:
3-30 V; 6-60 V; 30-300 V; 60-600 V
1115
-1216
/1418
2125
-2226
/2428
Output contacts - open-circuit principle
A1-A2 Control supply voltage
B-C Measuring ranges AC/DC:
3-30 V; 6-60 V; 30-300 V;
60-600 V
1115
-1216
/1418
2125
-2226
/2428
Output contacts - open- or closed circuit principle
1 ONOFF
Undervoltage monitoringOvervoltage monitoring
OFF = Default
1 ONOFF
ON-delayOFF-delay
2 ONOFF
Closed-circuit principleOpen-circuit principle
3 ONOFF
Latching function activatedLatching function not activated
4 ONOFF
2x1 c/o contact1x2 c/o contacts
OFF = Default
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/22
2
Current monitoring relays, single-phase
Technical data - Current monitoring relays
Type CM-SRS.1 CM-SRS.2 CM-SRS.M CM-SFS.2
Input circuit - Supply circuit A1-A2Rated control supply voltage U
sA1-A2 110-130 V AC
A1-A2 220-240 V AC
A1-A2 24-240 V AC/DC
Rated control supply voltage Us tolerance -15...+10 %
Rated frequency AC versions 50/60 Hz
AC/DC versions 50/60 Hz or DC
Current / power consumption see data sheets
Power failure buffering time 20 ms
Transient overvoltage protection Varistors
Input circuit - Measuring circuit B1/B2/B3-CMonitoring function over- or undercurrent monitoring
configurableover- and under- current monitoring
Measuring method True RMS measuring principle
Measuring inputs CM-SxS.x1 CM-SxS.x2
Terminal connection B1-C B2-C B3-C B1-C B2-C B3-CMeasuring ranges AC/DC 3-30 mA 10-100 mA 0.1-1 A 0.3-1.5 A 1-5 A 3-15 A 2)
Input resistance 3.3 � 1 � 0.1 � 0.05 � 0.01 � 0.0025 �Pulse overload capacity t < 1 s 500 mA 1 A 10 A 15 A 50 A 100 A
Continous capacity 50 mA 150 mA 1.5 A 2 A 7 A 17 A
Threshold value(s) adjustable within the indicated measuring range
Setting accuracy of threshold value 10 %
Hysteresis related to the threshold value 3-30 % adjustable 5 % fixed
Measuring signal frequency range DC / 15 Hz - 2 kHz
Rated measuring signal frequency range DC / 50-60 Hz
Maximum response time AC: 80 ms / DC: 120 ms
Accuracy within the control supply voltage tolerance �U � 0.5 %Accuracy within the temperature range �U � 0.06 % / °C
Timing circuitStart-up delay T
Snone 0 or 0.1-30 s adjustable
Tripping delay TV
none 0 or 0.1-30 s adjustable
Repeat accuracy (constant parameters) �0.07 % of full scaleAccuracy within the control supply voltage tolerance - �t � 0.5 %Accuracy within the temperature range - �t � 0.06 % / °C
Indication of operational statesControl supply voltage U/T: green LED V: control supply voltage applied,
X: start-up delay TS active,
W: tripping delay TV active
Measured value I: red LED V: overcurrent, W: undercurrent
Relay status R: yellow LED V: relay energized, no latching function Z: relay energized, active latching function Y: relay de-energized, active latching function
Output circuits 11(15)-12(16)/14(18), 21(25)-22(26)/24(28) - RelaysKind of output 1 c/o contact 2 c/o contacts 1x2 c/o contacts
or 2x1 c/o contact configurable
Operating principle open-circuit principle 1) open- or closed-circuit principle configurable 1)
Contact material AgNi
Rated operational voltage Ue
IEC/EN 60947-1 250 V
Minimum switching voltage / minimum switching current 24 V / 10 mA
Maximum switching voltage / maximum switching current 250 V AC / 4 A AC
Rated operational current Ie
(IEC/EN 60947-5-1)AC-12 (resistive) at 230 V 4 A
AC-15 (inductive) at 230 V 3 A
DC-12 (resistive) at 24 V 4 A
DC-13 (inductive) at 24 V 2 A
AC rating (UL 508)
Utilization category (Control Circuit Rating Code)
B 300
max. rated operational voltage 300 V AC
max. continuous thermal current at B 300 5 A
max. making/breaking apparent power (Make/Break) at B 300
3600/360 VA
Mechanical lifetime 30x106 switching cycles
Electrical lifetime (AC-12, 230 V, 4 A) 0.1x106 switching cycles
Max. fuse rating to achieve short-circuit protection
n/c contact 6 A fast-acting 10 A fast-acting 6 A fast-acting
n/o contact 10 A fast-acting
1) Open-circuit principle: output relay energizes if the measured value exceeds b / falls below a the adjusted threshold value
Closed-circuit principle: output relay de-energizes if measured value exeeds b / falls below a the adjusted threshold value2) In case of measured currents > 10 A, lateral spacing has to be min. 10 mm
2/23 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Type CM-SRS.1 CM-SRS.2 CM-SRS.M CM-SFS.2
General dataMTBF on requestDuty time 100%Dimensions (W x H x D)
product dimensions 22.5 x 85.6 x 103.7 mm (0.89 x 3.37 x 4.08 in)
packaging dimensions 97 x 109 x 30 mm (3.82 x 4.29 x 1.18 in)
Weight net weight depending on device, see ordering details
gross weight depending on device, see ordering details
Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool
Mounting position any
Minimum distance to other units 10 mm (0.39 in) at measured current > 10 A 2)
Material of housing UL 94 V-0
Degree of protection housing / terminals IP50 / IP20
Electrical connectionWire size Screw connection technology Easy Connect Technology (Push-in)
fine-strand with(out) wire end ferrule 1 x 0.5-2.5 mm2 (1 x 20-14 AWG)2 x 0.5-1.5 mm2 (2 x 20-16 AWG)
2 x 0.5-1.5 mm2 (2 x 20-16 AWG)
rigid 1 x 0.5-4 mm2 (1 x 20-12 AWG)2 x 0.5-2.5 mm2 (2 x 20-14 AWG)
2 x 0.5-1.5 mm2 (2 x 20-16 AWG)
Stripping length 8 mm (0.32 in)
Tightening torque 0.6-0.8 Nm (5.31-7.08 lb.in) -
Environmental dataAmbient temperature range operation /
storage-20...+60 °C / -40...+85 °C
Damp heat (IEC 60068-2-30) 55 °C, 6 cycles
Vibration (sinusoidal) (IEC/EN 60255-21-1) Class 2
Shock (IEC/EN 60255-21-2) Class 2
Isolation dataRated insulation voltage (VDE 0110, IEC 60947-1, IEC/EN 60255-5)
supply / measuring circuit / output
600 V
supply / output 1/2 250 V
Rated impulse withstand
voltage Uimp
(IEC/EN 60947-1,
IEC/EN 60255-5)
supply /measuring circuit / output
6 kV 1.2/50 μs
supply / output 1/2 4 kV 1.2/50 μs
Pollution degree (VDE 0110, IEC 664, IEC/EN 60255-5) 3
Overvoltage category (VDE 0110, IEC 664, IEC/EN 60255-5) III
StandardsProduct standard IEC/EN 60255-1, IEC/EN 60255-27, EN 50178
Low Voltage Directive 2006/95/EC
EMC Directive 2004/108/EC
Electromagnetic compatibilityInterference immunity to IEC/EN 61000-6-2
electrostatic discharge IEC/EN 61000-4-2 Level 3
radiated, radio-frequency, electromagnetic field
IEC/EN 61000-4-3 Level 3
electrical fast transient / burst IEC/EN 61000-4-4 Level 3
surge IEC/EN 61000-4-5 Level 3
conducted disturbances, induced by radio-frequency fields
IEC/EN 61000-4-6 Level 3
Interference emission IEC/EN 61000-6-3
high-frequency radiated IEC/CISPR 22; EN 55022 Class B
high-frequency conducted IEC/CISPR 22; EN 55022 Class B
Current monitoring relays, single-phase
Technical data - Current monitoring relays
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/24
2
Voltage monitoring relays, single-phase
Technical data - Voltage monitoring relays
Type CM-ESS.1 CM-ESS.2 CM-ESS.M CM-EFS.2
Input circuit - Supply circuit A1-A2Rated control supply voltage U
sA1-A2 110-130 V AC
A1-A2 220-240 V AC
A1-A2 24-240 V AC/DC
Rated control supply voltage Us tolerance -15...+10 %
Rated frequency AC versions 50/60 Hz
AC/DC versions 50/60 Hz or DC
Current / power consumption see data sheet
Power failure buffering time 20 ms
Transient overvoltage protection Varistors
Input circuit - Measuring circuit B-CMonitoring function over- or undervoltage monitoring
configurableover- and undervoltage monitoring configurable
Measuring method True RMS measuring principle
Measuring inputs
CM-ExSTerminal connection B-C B-C B-C B-C
Measuring range AC/DC 3-30 V 6-60 V 30-300 V 60-600 V
Input resistance 600 k� 600 k� 600 k� 600 k�Pulse overload capacity t < 1 s 800 V 800 V 800 V 800 V
Continous capacity 660 V 660 V 660 V 660 V
Threshold value(s) adjustable within the indicated measuring range
Setting accuracy of threshold value 10 %
Hysteresis related to the threshold value 3-30 % adjustable 5 % fixed
Measuring signal frequency range DC / 15 Hz - 2 kHz
Rated measuring signal frequency range DC / 50-60 Hz
Maximum response time AC: 80 ms / DC: 120 ms
Accuracy within the control supply voltage tolerance �U � 0.5 %Accuracy within the temperature range �U � 0.06 % / °CTransient overvoltage protection Varistors
Timing circuitDelay time T
Vnone 0 or 0.1-30 s adjustable
Repeat accuracy (constant parameters) �0.07 % of full scaleAccuracy within the control supply voltage tolerance - �t � 0.5 %Accuracy within the temperature range - �t � 0.06 % / °C
Indication of operational statesControl supply voltage U/T: green LED V: control supply voltage applied
W: tripping delay TV active
Measured value U: red LED V: overvoltage, W: undervoltage
Relay status R: yellow LED V: relay energized, no latching function Z: relay energized, active latching function Y: relay de-energized, active latching function
Output circuits Kind of output 1 c/o contact 2 c/o contacts 1x2 c/o contacts or
2x1 c/o contact configurable
Operating principle open-circuit principle 1) open- or closed-circuit principle configurable 1)
Contact material AgNi
Rated operational voltage Ue
IEC/EN 60947-1 250 V
Minimum switching voltage / minimum switching current 24 V / 10 mA
Maximum switching voltage / maximum switching current 250 V AC / 4 A AC
Rated operational current Ie (IEC/EN 60947-5-1)
AC-12 (resistive) at 230 V 4 A
AC-15 (inductive) at 230 V 3 A
DC-12 (resistive) at 24 V 4 A
DC-13 (inductive) at 24 V 2 A
AC rating (UL 508)
Utilization category (Control Circuit Rating Code) B 300
max. rated operational voltage 300 V AC
max. continuous thermal current at B 300 5 A
max. making/breaking apparent power (Make/Break) at B 300
3600/360 VA
Mechanical lifetime 30x106 switching cycles
Electrical lifetime AC-12, 230 V, 4 A 0.1x106 switching cycles
Max. fuse rating to achieve short-circuit protection
n/c contact 6 A fast-acting 10 A fast-acting 6 A fast-acting
n/o contact 10 A fast-acting
2/25 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Voltage monitoring relays, single-phase
Technical data - Voltage monitoring relays
1) Open-circuit principle: output relay energizes if the measured value exceeds d / falls below c the adjusted threshold value
Closed-circuit principle: output relay de-energizes if measured value exeeds d / falls below c the adjusted threshold value
Type CM-ESS.1 CM-ESS.2 CM-ESS.M CM-EFS.2General data
MTBF on request
Duty time 100%
Dimensions (W x H x D) product dimensions 22.5 x 85.6 x 103.7 mm (0.89 x 3.37 x 4.08 in)
packaging dimensions 97 x 109 x 30 mm (3.82 x 4.29 x 1.18 in)
Weight net weight depending on device, see ordering details
gross weight depending on device, see ordering details
Mounting DIN rail (IEC/EN 60715), snap-on mounting without any toolMounting position any
Minimum distance to other units vertical / horizontal not necessary / not necessary
Material of housing UL 94 V-0
Degree of protection housing / terminals IP50 / IP20
Environmental data
Ambient temperature ranges operation -20...+60 °C
storage -40...+85 °C
Damp heat, cyclic (IEC/EN 60068-2-30) 55 °C, 6 cycle
Vibration, sinusoidal (IEC/EN 60255-21-1) Class 2
Shock (IEC/EN 60255-21-2) Class 2
Electrical connection
Wire size Screw connection technology Easy Connect Technology (Push-in)fine-strand with(out) wire end ferrule 1 x 0.5-2.5 mm2 (1 x 20-14 AWG)
2 x 0.5-1.5 mm2 (2 x 20-16 AWG)2 x 0.5-1.5 mm2 (2 x 20-16 AWG)
rigid 1 x 0.5-4 mm2 (1 x 20-12 AWG)2 x 0.5-2.5 mm2 (2 x 20-14 AWG)
2 x 0.5-1.5 mm2 (2 x 20-16 AWG)
Stripping length 8 mm (0.32 in)
Tightening torque 0.6-0.8 Nm (5.31-7.08 lb.in) -
Isolation data
Rated insulation voltage (VDE 0110, IEC 60947-1, IEC/EN 60255-5)
supply / measuring circuit / output
600 V
supply / output 1/2 250 VRated impulse withstand voltage U
imp
(IEC/EN 60947-1, IEC/EN 60255-5)supply / measuring
circuit / output6 kV 1.2/50 μs
supply / output 1/2 4 kV 1.2/50 μsPollution degree (VDE 0110, IEC 664, IEC/EN 60255-5) 3
Overvoltage category (VDE 0110, IEC 664, IEC/EN 60255-5) III
StandardsProduct standard IEC/EN 60255-1, IEC/EN 60255-27, EN 50178
Low Voltage Directive 2006/95/EC
EMC Directive 2004/108/EC
Electromagnetic compatibility
Interference immunity to IEC/EN 61000-6-2
electrostatic discharge IEC/EN 61000-4-2 Level 3
radiated, radio-frequency, electromagnetic field
IEC/EN 61000-4-3 Level 3
electrical fast transient / burst IEC/EN 61000-4-4 Level 3
surge IEC/EN 61000-4-5 Level 3
conducted disturbances, induced by radio-frequency fields
IEC/EN 61000-4-6 Level 3
Interference emission IEC/EN 61000-6-3
high-frequency radiated IEC/CISPR 22; EN 55022 Class B
high-frequency conducted IEC/CISPR 22; EN 55022 Class B
2
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/26
Current and voltage monitoring relays, single-phase
Notes
2/27 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Three-phase monitoring relays
Product group picture
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/28
2
Three-phase monitoring relays
Table of contents
Three-phase monitoring relays
Benefits and advantages, Applications 2/29
Operating controls 2/30
Selection table singlefunctional 2/31
Selection table multifunctional 2/32
Ordering details - Singlefunctional 2/33
Ordering details - Multifunctional 2/34
Function diagrams 2/35
Connection diagrams 2/39
DIP switches, Rotary switches 2/40
Technical data 2/41
2/29 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Extended functionalityABB’s new generation of three-phase monitoring relays feature
additional functions making the application field for the de-
vices considerably larger.
Selectable phase sequence monitoringThe phase sequence monitoring can be switched off by
means of a rotary switch or a DIP switch. This enables moni-
toring of three-phase mains where phase sequence is not
relevant for the application, for example in case of motors with
forward and reverse rotation, heating applications, etc.
Automatic phase sequence correctionThe automatic phase sequence correction is activated by
means of a DIP switch. With activated phase sequence
correction, it is ensured that for any non-fixed or portable
equipment, e.g. construction machinery, the correct phase
sequence is always applied to the input terminals of the load.
For details regarding the wiring, please see function descrip-
tion / diagrams.
Structure of the type designationCM-_ _ x.yz
x: width of enclosure
y: Control supply voltage / measuring range
1 110, 115, 120, 127 V supply systems (phase-
neutral)
2 220, 230, 240 V supply systems (phase-neutral)
3 200, 208, 220, 230, 240, 257, 260 V supply sys-
tems (phase-phase)
4 440, 460 V supply systems (phase-phase)
5 480, 500 V supply systems (phase-phase)
6 575, 600 V supply systems (phase-phase)
7 660, 690 V supply systems (phase-phase)
8 200, 400 V supply systems (phase-phase)
z: Rated frequency / output circuit
1 50/60 Hz – 1x2 c/o
2 50/60 Hz – 1x2 or 2x1 c/o
3 50/60/400 Hz – 1x2 oder 2x1 c/o
Three-phase monitoring relays
Benefits and advantages, Applications
Phase unbalance monitoringIf the supply by the three-phase system is unbalanced due to
uneven distribution of the load, the motor will convert a part of
the energy into reactive power. This energy gets lost unex-
ploited; also the motor is exposed to higher thermal stress.
Other thermal protection devices fail to dete ct continuing
unbalances which can lead to damage or destruction of the
motor. The CM range three-phase monitors with phase unbal-
ance monitoring can reliably detect this critical situation.
Phase sequenceChanging the phase sequence during operation or a wrong
phase sequence prior to startup causes a change of the rota-
tional direction of the connected device. Generators, pumps
or fans rotate in the wrong direction and the installation is no
longer working properly. Especially for moveable equipment,
such as construction machinery, phase sequence detection
prior to the startup process is highly reasonable.
Phase lossIn case of phase loss, undefined stats of the installation are
likely to occur. E.g. the startup process of motors is disturbed.
All three-phase monitors of the ABB CM range detect a phase
loss as soon as the voltage of one phase drops below 60% of
its nominal value.
Voltage monitoringAll electric devices can be damaged when operated continu-
ously in a network with out-of-range voltages. For example,
safe starting is not ensured in case of undervoltage. Also,
the switching state of a contactor is not clearly defined when
operated in a „forbidden“ voltage range. This can lead to un-
defined states of the installtion and cause damage or destruc-
tion of valuable parts.
Characteristics of the CM range three-phase monitors – Adjustable phase unbalance threshold value 1)
– Adjustable ON-delay/OFF-delay time 1)
– Dual frequency measuring 50/60 Hz
– Powered by the measuring circuit
– 1 n/o contact, 1 or 2 c/o contacts
– LEDs for the indication of operational states
– Multifunctional and single-functional devices
– Phase failure detection
– Phase sequence monitoring 1)
– Over- and undervoltage monitoring (fixed or adjustable)1)
– Wide-range operating voltage guarantees world-wide operation
– Approvals / Marks
A C R K E 2)
/ a b1) depending on device type2) Applicable in rail application following the latest standards for rail applications: NF
F 16-101/102 (I2/F2 classified), EN 45545 (Hazard Level 3), DIN 5510, EN 50155,
IEC 60571. Further information is available in our rail segment brochure
2CDC110084B0201.
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/30
2
Three-phase monitoring relays
Operating controls
4
1
2
3
5
1 Adjustment of the hysteresis >U for overvoltage
2 Adjustment of the threshold value <U for undervoltage
3 Indication of operational states R/T: red LED – Relay status / timing
F1: yellow LED – Fault message
F2: yellow LED – Fault message
4 Adjustment of the threshold value Asym. for phase unbalance
5 Adjustment of the tripping delay Tv
6 DIP switches (see DIP switch functions on page 2/40) A ON-delay
B OFF-delay
l Phase sequence monitoring deactivated
k Phase sequence monitoring activated
m Phase sequence correction activated
n Phase sequence correction deactivated
i 2x1 c/o (SPDT) contact
j 1x2 c/o (SPDT) contacts
1 Adjustment of the hysteresis >U for overvoltage
2 Adjustment of the threshold value Asym. for phase unbalance
3 Indication of operational states R/T: red LED – Relay status / timing
F1: yellow LED – Fault message
F2: yellow LED – Fault message
4 Adjustment of the tripping delay Tv
5 Adjustment of the hysteresis <U for undervoltage
6 DIP switches (see DIP switch functions on page 2/40) A ON-delay
B OFF-delay
l Phase sequence monitoring deactivated
k Phase sequence monitoring activated
m Phase sequence correction activated
n Phase sequence correction deactivated
i 2x1 c/o (SPDT) contact
j 1x2 c/o (SPDT) contacts
1
3
2
4
5
6
S-Range Housing
N-Range Housing
2C
DC
25
3 0
17
F0
01
32
CD
C 2
53
01
6 F
00
13
2/31 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Three-phase monitoring relays
Selection table singlefunctional
Ord
er n
um
ber
1S
VR
55
08
81R
94
00
1S
VR
55
08
82
R9
50
0
1S
VR
55
0870
R9
40
0
1S
VR
55
0871R
95
00
1S
VR
55
08
24
R910
0
1S
VR
73
08
24
R9
30
0
1S
VR
740
824
R9
30
0
1S
VR
73
078
4R
23
00
1S
VR
74078
4R
23
00
1S
VR
73
078
4R
33
00
1S
VR
74078
4R
33
00
1S
VR
73
079
4R
13
00
1S
VR
73
079
4R
33
00
1S
VR
74079
4R
33
00
1S
VR
73
079
4R
23
00
1S
VR
74079
4R
23
00
1S
VR
73
07
74R
13
00
1S
VR
7407
74R
13
00
1S
VR
73
07
74R
33
00
1S
VR
7407
74R
33
00
Rated control supply voltage Us
Typ
e
CM
-PB
E
CM
-PB
E
CM
-PV
E
CM
-PV
E
CM
-PF
E
CM
-PFS
.S
CM
-PFS
.P
CM
-PS
S.3
1S
CM
-PS
S.3
1P
CM
-PS
S.4
1S
CM
-PS
S.4
1P
CM
-PV
S.3
1S
CM
-PV
S.4
1S
CM
-PV
S.4
1P
CM
-PV
S.8
1S
CM
-PV
S.8
1P
CM
-PA
S.3
1S
CM
-PA
S.3
1P
CM
-PA
S.4
1S
CM
-PA
S.4
1P
Phase to Phase160-300 V AC � � �200-400 V AC � �200-500 V AC � �208-440 V AC �300-500 V AC � � � �320-460 V AC � �350-580 V AC
380 V AC � �380-440 V AC � �400 V AC � �Phase to Neutral185-265 V AC �220-240 V AC �
Rated frequency50/60 Hz � � � � � � � � � � � � � � � � � � � �Suitable for monitoring
Single-phase mains � �
Three-phase mains � � � � � � � � � � � � � � � � � � � �
Monitoring function
Phase failure � � � � � � � � � � � � � � � � � � � �
Phase sequence � � � sel sel sel sel sel sel sel sel sel � � � �
Automatic phase sequence correction
Overvoltage � � � � � � � � � � �
Undervoltage � � � � � � � � � � �
Unbalance � � � �
Neutral 1) � �
Thresholds fix fix fix fix fix fix fix fix fix fix fix fix adj adj adj adj adj adj adj adj
Timing functions for tripping delay
ON delay fix fix sel sel sel sel
On and OFF delay fix fix fix fix fix adj adj adj adj adj adj adj adj adj
Connection type
Push-in terminals � � � � � �Double-chamber cage connection terminals
� � � � � � �
adj: adjustable
sel: selectable
1) The external conductor voltage towards the neutral conductor is measured.
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/32
2
Three-phase monitoring relays
Selection table multifunctional
adj: adjustable
sel: selectable
Ord
er n
um
ber
1S
VR
73
08
85
R13
00
1S
VR
740
88
5R
13
00
1S
VR
73
08
85
R3
30
0
1S
VR
740
88
5R
33
00
1S
VR
73
08
84
R13
00
1S
VR
740
88
4R
13
00
1S
VR
73
08
84
R3
30
0
1S
VR
740
88
4R
33
00
1S
VR
73
08
85
R4
30
0
1S
VR
740
88
5R
43
00
1S
VR
73
08
84
R4
30
0
1S
VR
740
88
4R
43
00
1S
VR
75
04
87R
83
00
1S
VR
76
04
87R
83
00
1S
VR
75
04
88
R8
30
0
1S
VR
76
04
88
R8
30
0
1S
VR
75
04
89
R8
30
0
1S
VR
76
04
89
R8
30
0
Rated control supply voltage Us
Typ
e
CM
-MP
S.1
1S
CM
-MP
S.1
1P
CM
-MP
S.2
1S
CM
-MP
S.2
1P
CM
-MP
S.3
1S
CM
-MP
S.3
1P
CM
-MP
S.4
1S
CM
-MP
S.4
1P
CM
-MP
S.2
3S
CM
-MP
S.2
3P
CM
-MP
S.4
3S
CM
-MP
S.4
3P
CM
-MP
N.5
2S
CM
-MP
N.5
2P
CM
-MP
N.6
2S
CM
-MP
N.6
2P
CM
-MP
N.7
2S
CM
-MP
N.7
2P
Phase to Phase160-300 V AC � �300-500 V AC � � � �350-580 V AC � �450-720 V AC � �530-820 V AC � �Phase to Neutral90-170 V AC � �180-280 V AC � � � �
Rated frequency50/60 Hz � � � � � � � � � � � � � �50/60/400 Hz � � � �Suitable for monitoring
Single-phase mains � � � � � �
Three-phase mains � � � � � � � � � � � � � � � � � �
Monitoring function
Phase failure � � � � � � � � � � � � � � � � � �
Phase sequence sel sel sel sel sel sel sel sel adj adj adj adj adj adj adj adj adj adj
Automatic phase sequence correction adj adj adj adj adj adj adj adj adj adj
Overvoltage � � � � � � � � � � � � � � � � � �
Undervoltage � � � � � � � � � � � � � � � � � �
Unbalance � � � � � � � � � � � � � � � � � �
Neutral 1) �2) �2) �2) �2) �2) �2)
Thresholds adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj
Timing functions for tripping delay
On and OFF delay adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj
Connection type
Push-in terminals � � � � � � � � �Double-chamber cage connection terminals
� � � � � � � � �
1) The external conductor voltage towards the neutral conductor is measured.2) Interrupted neutral monitoring
2/33 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Three-phase monitoring relays
Ordering details - Singlefunctional
Description
Only reliable and continuous monitoring of a three-phase network guarantees the trouble-free
and economic operation of machines and installations.
Ordering detailsRated control supply voltage = measuring voltage
Monitoring function
Neutral monitor-ing
Type Order code Price
1 pce
Weight(1 pce)kg (lb)
3x380-440 V AC, 220-240 V C
Phase failure detection (Single- and three-phase)
CM-PBE 1) 1SVR550881R9400 0.08 (0.17)
3x380-440 V AC CM-PBE 1SVR550882R9500 0.08 (0.17)
3x320-460 V AC, 185-265 V AC
Over- / under-voltage and phase failure detection (Single- and three-phase)
CM-PVE 1) 1SVR550870R9400 0.08 (0.17)
3x320-460 V AC CM-PVE 1SVR550871R9500 0.08 (0.17)
3x208-440 V AC
Phase sequence monitoring and phase failure detection (Three-phase)
CM-PFE 2) 1SVR550824R9100 0.08 (0.17)
2C
DC
25
1 0
63
V0
01
12
CD
C 2
51
06
4 V
00
11
2C
DC
25
1 0
64
V0
01
1
CM-PAS.31P
CM-PSS.41P
CM-PBE
1) The version with neutral monitoring is also suitable for monitoring single-phase mains. For this, all three external conductors
(L1,L2,L3) have to be jumpered and connected as one single conductor.2) For applications where a reverse fed voltage >60% is expected, we recommend to use our three-phase monitoring relays for
unbalance CM-PAS.xx
Ordering detailsRated control supply voltage = measuring voltage
Monitoring function Type Order code Price
1 pce
Weight(1 pce)kg (lb)
3x200-500 V ACPhase sequence monitoring and phase failure detection (Three-phase)
CM-PFS.S 1SVR730824R9300 0.127 (0.280)
CM-PFS.P 1SVR740824R9300 0.119 (0.262)
3x380 V AC
Over- / undervoltage with fixed threshold values ± 10 %
CM-PSS.31S 1SVR730784R2300 0.132 (0.291)
CM-PSS.31P 1SVR740784R2300 0.123 (0.271)
3x400 V AC
CM-PSS.41S 1SVR730784R3300 0.132 (0.291)
CM-PSS.41P 1SVR740784R3300 0.123 (0.271)
3x160-300 V AC
Over- and undervoltage with adjustable threshold values (Three-phase)
CM-PVS.31S 1SVR730794R1300 0.141 (0.311)
CM-PVS.31P 1SVR740794R1300 0.132 (0.291)
3x300-500 V AC
CM-PVS.41S 1SVR730794R3300 0.139 (0.306)
CM-PVS.41P 1SVR740794R3300 0.131 (0.289)
3x200-400 V AC
CM-PVS.81S 1SVR730794R2300 0.136 (0.300)
CM-PVS.81P 1SVR740794R2300 0.128 (0.282)
3x160-300 V AC
Phase unbalance (Three-phase)
CM-PAS.31S 1SVR730774R1300 0.133 (0.293)
CM-PAS.31P 1SVR740774R1300 0.124 (0.273)
3x300-500 V AC
CM-PAS.41S 1SVR730774R3300 0.132 (0.291)
CM-PAS.41P 1SVR740774R3300 0.123 (0.271)
S: screw connection
P: push-in / easy connect
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/34
2
Three-phase monitoring relays
Ordering details - Multifunctional
Ordering detailsRated control supply voltage = measuring voltage
DIP switch
Monitoring function
Neutral monitoring
Type Order code Price
1 pce
Weight(1 pce)kg (lb)
90-170 V AC
ABkl
Multifunctional (Three-phase phase failure detection, Phase sequence monitoring, overvoltage, undervoltage, Phase unbalance)
CM-MPS.11S 1SVR730885R1300 0.148 (0.326)
CM-MPS.11P 1SVR740885R1300 0.137 (0.302)
180-280 V AC
CM-MPS.21S 1SVR730885R3300 0.146 (0.322)
CM-MPS.21P 1SVR740885R3300 0.135 (0.298)
3x160-300 V AC
CM-MPS.31S 1SVR730884R1300 0.142 (0.313)
CM-MPS.31P 1SVR740884R1300 0.133 (0.293)
3x300-500 V AC
CM-MPS.41S 1SVR730884R3300 0.140 (0.309)
CM-MPS.41P 1SVR740884R3300 0.132 (0.291)
180-280 V ACABklmnij
Multifunctional (Three-phase phase failure detection, Phase sequence monitoring, overvoltage, undervoltage, Phase unbalance)
CM-MPS.23S 1SVR730885R4300 0.149 (0.328)
CM-MPS.23P 1SVR740885R4300 0.138 (0.304)
3x300-500 V AC
CM-MPS.43S 1SVR730884R4300 0.148 (0.327)
CM-MPS.43P 1SVR740884R4300 0.137 (0.302)
3x350-580 V AC
ABklmnij
CM-MPN.52S 1SVR750487R8300 0.230 (0.507)
CM-MPN.52P 1SVR760487R8300 0.226 (0.498)
3x450-720 V AC
CM-MPN.62S 1SVR750488R8300 0.229 (0.505)
CM-MPN.62P 1SVR760488R8300 0.225 (0.496)
3x530-820 V AC
CM-MPN.72S 1SVR750489R8300 0.224 (0.494)
CM-MPN.72P 1SVR760489R8300 0.220 (0.485)
2C
DC
25
1 0
65
V0
01
1
2C
DC
25
1 0
62
V0
01
1
CM-MPS.23P
CM-MPN.52P
A ON-delayed
B OFF-delayed
k Phase sequence
monitoring activated
l Phase sequence
monitoring deactivated
m Phase sequence
correction activated
n Phase sequence
correction deactivated
i 2x1 c/o (SPDT) contacts
j 1x2 c/o (SPDT) contacts
S: screw connection
P: push-in / easy connect
2/35 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Three-phase monitoring relays
Function diagrams
L1, L2, L3, N
13-14
L1, L2, L3, N L1, L2, L3, N L1, L2, L3, N L1, L2, L3, NL1, L2L3
N
ts
L1, L2, N
L3
tv
L2, L3, N
L1
<ts ts <tv
2CD
C 2
52 0
45 F
0203
R: yellow LED
Measuring value
ts = Start-up delay fixed 500 mstv = Tripping delay fixed 150 ms
L1, L2, L3
13-14
L1, L2, L3 L1, L2, L3 L1, L2, L3 L1, L2, L3L1, L2
L3
ts
L1, L2
L3
tv
L1, L2
L3
<ts ts <tv
2CD
C 2
52 0
46 F
0203
R: yellow LED
Measuring value
ts = Start-up delay fixed 500 mstv = Tripping delay fixed 150 ms
Function diagrams - Phase failure detection CM-PBE
with neutral
without neutral
Function diagrams - Phase failure, under- / overvoltage detection CM-PVE
with neutral
without neutral
L1, L2, L3, N
13-14
Umax
Umax - 5 %
Umin + 5 %Umin
ts ts tstv tv<ts <tv
2CD
C 2
52 0
47 F
0203
R: yellow LED
Measuring value
L1, L2, L3
13-14
Umax
Umax - 5 %
Umin + 5 %Umin
ts tststv tv<ts <tv
2CD
C 2
52 0
48 F
0203
R: yellow LED
Measuring value
ts = Start-up delay fixed 500 mstv = Tripping delay fixed 500 ms
If all phases (and the neutral) are present, the output relay
energizes after the start-up delay ts is complete. If a phase
failure occurs, the tripping delay tv starts. When timing is com-
plete, the output relay de-energizes. As soon as the voltage
returns to the tolerance range, timing of ts starts. When timing
is complete, the output relay re-energizes automatically. The
yellow LED glows when the output relay is energized.
If all phases (and the neutral) are present with correct voltage,
the output relay energizes after the start-up delay ts is com-
plete. If the voltage exceeds or falls below the fixed threshold
value or if a phase failure occurs, the tripping delay tv starts.
When timing is complete, the output relay de-energizes. As
soon as the voltage returns to the tolerance range, timing of
ts starts. When timing is complete, the output relay re-ener-
gizes automatically. The yellow LED glows when the output
relay is energized.
Function diagram - Phase failure detection, phase sequence monitoring CM-PFE
L1, L2, L3
11-1211-14
L1, L2, L3 L1, L2, L3 L1, L2, L3L1, L3, L2 L1, L2
L3ts tv ts tvts
2CD
C 2
52 0
61 F
0208
R: yellow LED
Measuring value
ts = Start-up delay fixed 500 mstv = Tripping delay fixed 500 ms
If all phases are present with the correct phase sequence, the
output relay energizes after the start-up delay ts is complete. If
a phase failure or a phase sequence error occurs, the trip-
ping delay tv starts. When timing is complete, the output relay
de-energizes. The yellow LED glows when the output relay is
energized.
In case of motors which continue running with only two
phases, the CM-PFE detects phase failure if the reverse fed
voltage is less than 60 % of the originally applied voltage.
ATTENTIONIf several CM-PFS units are placed side by side and the control supply voltage is higher than 415 V, spacing of at least 10 mm has to be kept
between the individual units.
Function diagram - Phase failure detection, phase sequence monitoring CM-PFS
L1, L2, L3
11-1211-14
21-2221-24
L1, L2, L3 L1, L2, L3 L1, L2, L3 L1, L2, L3L1, L3, L2 L1, L2 L1
L3 L2, L3ts
2CD
C 2
52 0
13 F
0208
R: yellow LED
Measuring value
ts = start-up delay fixed 500 ms
If all phases are present with the correct phase sequence, the
output relay energizes after the start-up delay ts is complete. If
a phase failure or a phase sequence error occurs, the output
relay de-energizes instantaneous. The yellow LED glows when
the output relay is energized.
In case of motors which continue running with only two
phases, the CM-PFS detects phase failure if the reverse fed
voltage is less than 60 % of the originally applied voltage.
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/36
2
Three-phase monitoring relays
Function diagrams
K1
K1
K1
K3 H1
L1
L2
L3
N
16
28
A1
25
26
15
18
K2
A2
A1
A2
K1
K1
K1
K3 H1
L1
L2
L3
N
16
28
A1
25
26
15
18
K2
A2
A1
A2
-K3
L1
-F1
1
2
95
96
97
98
L2
3
4
L3
5
6
1
2
3
4
5
6-K2
-F2
1
2
3
4
5
6
1
3
5
2
4
6
M
3 ~
W1V1U1
-M1
2CD
C 2
52 0
87 F
0b07
CM-PSS.xx, CM-PVS.xx, CM.PAS.xx, CM-MPS.xx, CM-MPN.xx Phase sequence monitoring and phase failure detectionApplying control supply voltage begins the fixed start-up delay
tS. When t
S is complete and all phases are present with cor-
rect voltage, the output relays energize and the yellow LED
R/T glows.
Phase sequence monitoringIf phase sequence monitoring is activated, the output relays
de- energize as soon as a phase sequence error occurs. The
fault is displayed by alternated flashing of the LEDs F1 and
F2. The output relays re-energize automatically as soon as the
phase sequence is correct again.
Phase failure detectionThe output relays de-energize instantaneous if a phase failure
occurs. The fault is indicated by lightning of LED F1 and flash-
ing of LED F2. The output relays re-energize automatically as
soon as the voltage returns to the tolerance range.
25-2625-28
L1, L2, L3
15-1615-18
L1, L2, L3 L1, L2, L3 L1, L2, L3 L1, L2, L3L1, L3, L2 L1, L2 L1
L3 L2, L3ts
2CD
C 2
52 0
94 F
0207
F1: red LED
F2: red LED
R/T: yellow LED
Measuring value
ts = start-up delay fixed 200 ms
L1, L2, L3
15-1615-18
tS2
tS1 tS1
L1, L2, L3L1, L2, L3 L1, L3, L2L1, L2
L3
25-2625-28
tS2
2CD
C 2
52 0
85 F
0207
F1: red LED
F2: red LED
R/T: yellow LED
Measuring value
tS1 = start-up delay of R1 fixed 250 mstS2 = start-up delay of R2 fixed 200 ms
CM-MPS.x3, CM-MPN.x2 Automatic phase sequence correctionThis function can be selected only if phase sequence moni-
toring is activated k and operating mode 2x1 c/o (SPDT)
contact j is selected.
Applying control supply voltage begins the fixed start-up
delay tS1
. When tS1
is complete and all phases are present with
correct voltage, output relay R1 energizes. Output relay R2
energizes when the fixed start-up delay tS2
is complete and all
phases are present with correct phase sequence. Output relay
R2 remains de-energized if the phase sequence is incorrect.
If the voltage to be monitored exceeds or falls below the set
threshold values for phase unbalance, over- or undervoltage
or if a phase failure occurs, output relay R1 de-energizes and
the LEDs F1 and F2 indicate the fault.
Output relay R2 is responsive only to a false phase sequence.
In conjunction with a reversing contactor combination, this
enables an automatic correction of the rotation direction. See
circuit diagrams on the right.
CM-MPS.11, CM-MPS.21, CM-MPS.23 Interrupted neutral monitoringThe interruption of the neutral in the main to be monitored is
detected by means of phase unbalance evaluation.
Determined by the system, in case of unloaded neutral, i.e.
symmetrical load between all three phases, it may happen
that an interruption of the neutral will not be detected.
If the star point is displaced by asymmetrical load in the
three-phase main, an interrupted neutral will be detected.
Control circuit diagram (K1 = CM-MPS.23)
Control circuit diagram (K1 = CM-MPS.43 or CM-MPN.xx)
Power circuit diagram
Displacement of the star point
2C
DC
25
3 0
08
F0
01
4
2C
DC
25
3 0
09
F0
01
4
2/37 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
ON-delay A, 2x1 c/o contact i
OFF-delay B, 2x1 c/o contact i
OFF-delay B, 1x2 c/o contacts j
ON-delay A, 1x2 c/o contacts j
CM-PSS.xx1), CM-PVS.xx2), CM-MPS.xx2), CM-MPN.xx2) Over- and undervoltage monitoring jApplying control supply voltage begins the fixed start-up
delay tS. When t
S is complete and all phases are present with
correct voltage and with correct phase sequence, the output
relays energize and the yellow LED R/T glows.
Type of tripping delay = ON-delayIf the voltage to be monitored exceeds or falls below the
fixed1) or set2) threshold value, the output relays de-energize
after the set tripping delay tV is complete. The LED R/T flashes
during timing and turns off as soon as the output relays de-
energize.
The output relays re-energize automatically as soon as the
voltage returns to the tolerance range, taking into account a
fixed hysteresis of 5 % and the LED R/T glows.
Type of tripping delay = OFF-delayIf the voltage to be monitored exceeds or falls below the
fixed1) or set2) threshold value, the output relays de-energize
instantaneously and the LED R/T turns off.
As soon as the voltage returns to the tolerance range, tak-
ing into account a fixed hysteresis of 5 %, the output relays
re-energize automatically after the set tripping delay tV is
complete. The LED R/T flashes during timing and turns steady
when timing is complete.
L1, L2, L3
15-1615-18
25-2625-28
> U> U - 5 %
< U + 5 %< U
ts <tv<tvtv
2CD
C 2
52 0
07 F
0207
F1: red LED
F2: red LED
R/T: yellow LED
Measuring value
ts = start-up delay fixed 200 mstv = adjustable tripping delay
L1, L2, L3
15-1615-18
25-2625-28
> U> U - 5 %
< U + 5 %< U
ts tv tv<tv
2CD
C 2
52 0
06 F
0207
F1: red LED
F2: red LED
R/T: yellow LED
Measuring value
ts = start-up delay fixed 200 mstv = adjustable tripping delay
CM-MPS.x3, CM-MPN.x2 Over- and undervoltage monitoring iApplying control supply voltage begins the fixed start-up
delay tS. When t
S is complete and all phases are present with
correct voltage and with correct phase sequence, the output
relays energize. The yellow LED R/T glows as long as at least
one output relay is energized.
Type of tripping delay = ON-delayIf the voltage to be monitored exceeds or falls below the set
threshold value, output relay R1 (overvoltage) or output relay
R2 (undervoltage) de-energizes after the set tripping delay tV
is complete. The LED R/T flashes during timing.
The corresponding output relay re-energizes automatically as
soon as the voltage returns to the tolerance range, taking into
account a fixed hysteresis of 5 %.
Type of tripping delay = OFF-delayIf the voltage to be monitored exceeds or falls below the set
threshold value, output relay R1 (overvoltage) or output relay
R2 (undervoltage) de-energizes instantaneously.
As soon as the voltage returns to the tolerance range, taking
into account a fixed hysteresis of 5 %, the corresponding out-
put relay re-energizes automatically after the set tripping delay
tV is complete. The LED R/T flashes during timing.
L1, L2, L3
15-1615-18
> U> U - 5 %
< U + 5 %< U
ts tv tv<tv
25-2625-28
2CD
C 2
52 0
90 F
0207
F1: red LED
F2: red LED
R/T: yellow LED
Measuring value
ts = start-up delay fixed 200 mstv = adjustable tripping delay
25-2625-28
L1, L2, L3
15-1615-18
> U> U - 5 %
< U + 5 %< U
ts <tv<tvtv
2CD
C 2
52 0
91 F
0207
F1: red LED
F2: red LED
R/T: yellow LED
Measuring value
ts = start-up delay fixed 200 mstv = adjustable tripping delay
Three-phase monitoring relays
Function diagrams
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/38
2
Three-phase monitoring relays
Function diagrams
CM-PAS.xx, CM-MPS.xx, CM-MPN.xx Phase unbalance monitoringApplying control supply voltage begins the fixed start-up
delay tS. When t
S is complete and all phases are present with
correct voltage and with correct phase sequence, the output
relays energize and the yellow LED R/T glows.
Type of tripping delay = ON-delayIf the voltage to be monitored exceeds or falls below the
set phase unbalance threshold value, the output relays de-
energize after the set tripping delay tV is complete. The LED
R/T flashes during timing and turns off as soon as the output
relays de-energize.
The output relays re-energize automatically as soon as the
voltage returns to the tolerance range, taking into account a
fixed hysteresis of 20 % and the LED R/T glows.
Type of tripping delay = OFF-delay If the voltage to be monitored exceeds or falls below the set
phase unbalance threshold value, the output relays de-ener-
gize instantaneously and the LED R/T turns off.
As soon as the voltage returns to the tolerance range, taking
into account a fixed hysteresis of 20 %, the output relays
re-energize automatically after the set tripping delay tV is
complete. The LED R/T flashes during timing and turns steady
when timing is complete.25-2625-28
L1, L2, L3
15-1615-18
ts <tv<tvtv
L1, L2, L3 L1, L2
L3
2CD
C 2
52 0
93 F
0207
F1: red LED
F2: red LED
R/T: yellow LED
Measuring value
UnbalanceUnbalance - Hysteresis
Unbalance + HysteresisUnbalance
ts = start-up delay fixed 200 mstv = adjustable tripping delay
L1, L2, L3
15-1615-18
L1, L2, L3 L1, L2
L3
ts tv tv<tv
25-2625-28
2CD
C 2
52 0
92 F
0207
F1: red LED
F2: red LED
R/T: yellow LED
Measuring value
UnbalanceUnbalance - Hysteresis
Unbalance + HysteresisUnbalance
ts = start-up delay fixed 200 mstv = adjustable tripping delay
OFF-delay B
ON-delay A
CM-PSS.xx, CM-PSV.xx, CM-PAS.xx, CM-MPS.xx, CM-MPN.xx LED functions
Function R/T:
yellow LED
F1:
red LED
F2:
red LEDControl supply voltage applied, output relay energized
V - -
Tripping delay tV active W - -
Phase failure - V WPhase sequence - W alternatingOvervoltage - V -
Undervoltage - - VPhase unbalance - V VInterruption of the neutral - V WAdjustment error 1) W W W
1) Possible misadjustments of the front-face operating controls:
Overlapping of the threshold values: An overlapping of the threshold values is
given, if the threshold value for overvoltage is set to a smaller value than the
threshold value for undervoltage.
DIP switch 3 = OFF and DIP switch 4 = ON: Automatic phase sequence
correction is activated and selected operating mode is 1x2 c/o contacts
DIP switch 2 and 4 = ON: Phase sequence detection is deactivated and the
automatic phase sequence correction is actived
CM-PSS.xx, CM-PSV.xx, CM-PAS.xx, CM-MPS.xx, CM-MPN.xx Type of tripping delayThe type of tripping delay A / B can be adjusted via a
rotary (CM-PxS.xx) or a DIP switch (CM-MPx.xx).
Switch position ON-delay A:
In case of a fault, the de-energizing of the output relays and
the respective fault message are suppressed for the adjusted
tripping delay tV.
Switch position OFF-delay B:
In case of a fault, the output relays de-energize instanta-
neously and a fault message is displayed and stored for the
length of the adjusted tripping delay tV. Thereby, also momen-
tary undervoltage conditions are recognized.
2/39 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Three-phase monitoring relays
Connection diagrams
1S
VC
11
0 0
00
F0
11
7
Connection diagram CM-PFE
Connection diagram CM-PFS
L1 L2
28252618
L3
L3 15
16 18 26 28
25L2L1
16 15
Connection diagram CM-PVS.x1, CM-PSS.x1, CM-PAS.x1
L1 L2
282615 25
L3
L3 15
16 18 26 28
25L2L1
16 18
Connection diagram CM-MPN.x2
1S
VC
11
0 0
00
F 0
11
8
L1, L2, L3, (N) Control supply voltage = Measuring voltage
13-14 Output contact - closed-circuit principle
L1, L2, L3 Control supply voltage = Measuring voltage
15-16/1825-26/28
Output contact - closed-circuit principle
L1, L2, L3 Control supply voltage = Measuring voltage
1115
-1216
/1418
2125
-2226
/2428
Output contact - closed-circuit principle
L1, L2, L3, (N) Control supply voltage = Measuring voltage
15-16/1825-26/28
Output contact - closed-circuit principle
L1, L2, L3, (N) Control supply voltage = Measuring voltage
15-16/1825-26/28
Output contact - closed-circuit principle
L1, L2, L3 Control supply voltage = Measuring voltage
15-16/1825-26/28
Output contact - closed-circuit principle
L1, L2, L3 Control supply voltage = Measuring voltage
11-12/14 Output contact - closed-circuit principle
Connection diagrams CM-PBE, CM-PVE
with neutral without neutral
L1N
L2
28252618
L3
L3 15
16 18 26 28
25L2
N
L1
16 15
L1 L2
28252618
L3
L3 15
16 18 26 28
25L2L1
16 15
Connection diagram CM-MPS.11, CM-MPS.21, CM-MPS.23
Connection diagram CM-MPS.31, CM-MPS.41, CM-MPS.43
2C
DC
25
2 0
38
F0
b0
82
CD
C 2
52
03
7 F
0b
08
1S
VC
11
0 0
00
F 0
11
2
1S
VC
11
0 0
00
F 0
11
3
2C
DC
25
2 0
36
F0
b0
8
2C
DC
25
2 0
37
F0
b0
8
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/40
2
Three-phase monitoring relays
DIP switches, Rotary switches
Rotary switch "Function" CM-PSS
ON-delay with phase sequence monitoring
OFF-delay with phase sequence monitoring
ON-delay without phase sequence monitoring
OFF-delay without phase sequence monitoring
Rotary switch "Function" CM-PVS
ON-delay with phase sequence monitoring
OFF-delay with phase sequence monitoring
ON-delay without phase sequence monitoring
OFF-delay without phase sequence monitoring
Position 1 2
ON
OFF
2CD
C 2
52 0
40 F
0b08
Position 4 1 2 3
ON
OFF
2CD
C 2
52 0
41 F
0b08
DIP switch functions CM-MPS.x3 and CM-MPN.x2
1 Timing function 2 Phase sequence monitoringONOFF
ON-delayedOFF-delayed
ON
OFF
deactivated
activated
3 Operating principle of output 4 Phase sequence correctionONOFF
2x1 c/o contact1x2 c/o contact
ONOFF
activateddeactivated
DIP switch functions CM-MPS.x1
1 Timing function 2 Phase sequence monitoringONOFF
ON-delayedOFF-delayed
ONOFF
deactivatedactivated
Output relay R1 is responsive to overvoltage, output relay R2 is responsive
to undervoltage. In case of other faults, both output relays react
synchronously.
2/41 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Three-phase monitoring relays
Technical data
Type CM-PBE 1) CM-PBE CM-PVE 1) CM-PVE CM-PFE CM-PFS
Supply circuit = measuring circuit L1-L2-L3-N L1-L2-L3 L1-L2-L3-N L1-L2-L3 L1-L2-L3Rated control supply voltage U
S = measuring voltage 3x380-
440 V AC, 220-240 V AC
3x380- 440 V AC
3x320- 460 V AC, 185-265 V AC
3x320- 460 V AC
3x208- 440 V AC
3x200- 500 V AC
Power consumption approx. 15 VA
Rated control supply voltage US tolerance -15...+15 % -15...+10 % -10...+10 % -15...+10 %
Rated frequency 50/60 Hz 50/60 Hz (-10...+10 %) 50/60 Hz
Duty time 100 %
Measuring circuit L1-L2-L3-N L1-L2-L3 L1-L2-L3-N L1-L2-L3 L1-L2-L3
Monitoring functions phase failure � � � � � �phase sequence - - - - � �
over- / undervoltage - - � � - -
neutral � - � - - -
Measuring ranges 3x380-440 V AC, 220-240 V AC
3x380- 440 V AC
3x320- 460 V AC, 185-265 V AC
3x320- 460 V AC
3x208- 440 V AC
3x200- 500 V AC
Thresholds Umin
0.6 x UN fixed 185 V / 320 V
fixed 320 V
0.6 x UN
Umax
fixed 265 V / 460 V
fixed 460 V
Hysteresis related to the threshold value fixed 5 % (release value = 0.65 x U
N)
fixed 5 % -
Measuring voltage frequency 50/60 Hz (-10 %...+10 %) 50/60 Hz
Response time 40 ms 80 ms 500 ms
Accuracy within the rated control supply voltage tolerance - �U � 0.5 %
Accuracy within the temperature range - �U � 0.06 % / °C
Timing circuitStart-up delay t
Sfixed 500 ms (�20 %) fixed 500 ms
Tripping tV
fixed 150 ms (�20 %)
at over-/ undervoltage fixed 500 ms (�20 %)
fixed 500 ms
-
Indication of operational statesRelay status R: yellow LED V Output relay energized
Fault message F: red LED Only CM-PFS: V Phase failure / V Phase sequence error
Output circuits 13-14 11-12/141115-1216 / 1418,
2125-2226 / 2428
Kind of output 1 n/o contact 1 c/o contact
2 c/o contacts
Operating principle closed-circuit principle 2)
Contact material AgCdO AgNi allow, Cd free
Rated operational voltage Ue
IEC/EN 60947-1 250 V 250 V AC
Minimum switching voltage / Minimum switching current - / -
Maximum switching voltage 250 V AC, 250 V DC
Rated operational current Ie
(IEC/EN 60947-5-1)AC-12 (resistive) 230 V 4 A
AC-15 (inductive) 230 V 3 A
DC-12 (resistive) 24 V 4 A
DC-13 (inductive) 24 V 2 A
Mechanical lifetime 30 x 106 switching cycles
Electrical lifetime (AC-12, 230 V, 4 A) 0.1 x 106 switching cycles
Max. fuse rating to achieve short-circuit protection
n/c contact 10 A fast-acting 6 A fast- acting
n/o contact 10 A fast-acting
AC rating (UL 508)
Utilization category (Control Circuit Rating Code) B 300, CM-PFS: B300, pilot duty general purpose (250 V, 4 A, cos phi 0.75)
max. rated operational voltage 300 V AC
max. continuous thermal current at B 300 5 A
max. making/breaking apparent power at B 300 3600/360 VA
1) Device with neutral monitoring: The external conductor voltage towards the neutral conductor is measured.2) Closed-circuit principle: Output relay is de-energized if the measured value exceeds/drops below the adjusted threshold.
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/42
2
Type CM-PBE 1) CM-PBE CM-PVE 1) CM-PVE CM-PFE CM-PFS
General dataDimensions (W x H x D) 22.5 x 78 x 78.5 mm (0.89 x 3.07 x 3.09 in)
CM-PFS: 22.5 x 78 x 100 mm (0.89 x 3.07 x 3.94 in)
Weight see data sheet
Mounting DIN rail (IEC/EN 60715)
Mounting position any
Degree of protection housing / terminals IP50 / IP20
Electrical connectionWire size fine-strand with wire end ferrule 2 x 0.75-1.5 mm² (2 x 18-16 AWG) Same as
CM-PSS.31, see page 2/44.fine-strand without wire end ferrule 2 x 1-1.5 mm² (2 x 18-16 AWG)
rigid 2 x 0.75-1.5 mm² (2 x 18-16 AWG)
Stripping length 10 mm (0.39 in) Same as CM-PSS.31, see page 2/44.
Tightening torque 0.6-0.8 Nm
Environmental dataAmbient temperature range operation / storage -20..+60 °C / -40...+85 °C
Environmental testing (IEC 68-2-30) 24 h cycle time, 55 °C, 93 % rel., 96 h -
Operational reliability (IEC 68-2-6) 6 g -
Mechanical resistance (IEC 68-2-6) 10 g -
Climatic category IEC/EN 60721-3-3 - 3K3
Damp heat, cyclic IEC/EN 60068-2-30 CM-PFS: 6 x 24 h cycle, 55 °C, 95 % RH
Vibration, sinusoidal IEC/EN 60255-21-1 - Class 2
Shock IEC/EN 60255-21-2 - Class 2
Isolation dataRated insulation voltage U
i
(IEC/EN 60947-1, IEC/EN 60664-1)between supply,
measuring and output circuits
400 V -
supply circuit / output circuit
- 600 V
output circuit 1 / output circuit 2
- 300 V
Rated impulse withstand voltage Uimp
between all isolated circuits (VDE 0110, IEC 664)
4 kV / 1.2 - 50 μs -
supply circuit / output circuit
- 6 kV
output circuit 1 / output circuit 2
- 4 kV
Basic insulation for rated control supply voltage (IEC/EN 60664-1)
supply circuit / output circuit
- 600 V AC
Protective seperation (IEC/EN 61140, EN 50178)
supply circuit / output circuit
- n/a
Test voltage (routine test) 2.5 kV, 50 Hz, 1 min. -
supply circuit / output circuit
- 2.5 kV, 50 Hz, 1 min.
output circuit 1 / output circuit 2
- 2.5 kV, 50 Hz, 1 min.
Pollution degree (IEC/EN 60664-1) 3
Overvoltage category (IEC/EN 60664-1) III
StandardsProduct standard IEC 255-6, EN 60255-6, CM-PFS: IEC/EN 60255-1, IEC/EN 60255-27, EN 50178
Low Voltage Directive 2006/95/EC
EMC Directive 2004/108/EC
RoHS Directive CM-PFS: 2011/65/EC
Electromagnetic compatibilityInterference immunity to EN 61000-6-2, CM-PFS: EN 61000-6-1, EN 61000-6-2
electrostatic discharge IEC/EN 61000-4-2 Level 3 - 6 kV/ 8 kV
radiated, radio-frequency, electromagnetic field
IEC/EN 61000-4-3 Level 3 - 10 V/m (1 GHz) / 3 V/m (2 GHz) / 1 V/m (2.7 GHz)
electrical fast transient / burst IEC/EN 61000-4-4 Level 3 - 2 kV / 5 kHz
surge IEC/EN 61000-4-5 Level 4 - 2 kVL-L
conducted disturbances, induced by radio-frequency fields
IEC/EN 61000-4-6 Level 3 - 10 V
voltage dips, short interruptions and voltage variations
IEC/EN 61000-4-11 - Class 3
harmonics and interharmonics IEC/EN 61000-4-13 - Class 3
Interference emission EN 61000-6-4, CM-PFS: EN 61000-6-3, EN 61000-6-4high-frequency radiated IEC/CISPR 22, EN 55022 Class B
high-frequency conducted IEC/CISPR 22, EN 55022 Class B
1) Device with neutral monitoring: The external conductor voltage towards the neutral conductor is measured.
Three-phase monitoring relays
Technical data
2/43 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Three-phase monitoring relays
Technical data
Type CM-PSS.31 CM-PSS.41 CM-PVS.31 CM-PVS.41 CM-PVS.81 CM-PAS.31 CM-PAS.41
Input circuit = Measuring circuit L1, L2, L3Rated control supply voltage U
S = measuring voltage 3x380 V AC 3x400 V AC 3x160-
300 V AC3x300-500 V AC
3x200-400 V AC
3x160-300 V AC
3x300-500 V AC
Rated control supply voltage US tolerance -15...+10 %
Rated frequency 50/60 Hz
Frequency range 45-65 Hz
Typical current / power consumption 25 mA / 18 VA (380 V AC)
25 mA / 18 VA (400 V AC)
25 mA / 10 VA (230 V AC)
25 mA / 18 VA (400 V AC)
19 mA / 10 VA (300 V AC)
25 mA / 10 VA (230 V AC)
25 mA /18 VA (400 V AC)
Measuring circuit L1, L2, L3Monitoring functions Phase failure � � � � � � �
Phase sequence can be switched off � �Automatic phase sequence
correction- - - - - - -
Over- / undervoltage � � � � � - -
Phase unbalance - - - - - � �Neutral - - - - - - -
Measuring range Overvoltage 3x418 V AC 3x440 V AC 3x220- 300 V AC
3x420- 500 V AC
3x300- 400 V AC
- -
Undervoltage 3x342 V AC 3x360 V AC 3x160- 230 V AC
3x300- 380 V AC
3x210- 300 V AC
- -
Phase unbalance
- - - - - 2-25 % of average of phase voltages
Thresholds Overvoltage fixed adjustable within measuring range - -
Undervoltage fixed adjustable within measuring range - -
Phase unbalance (switch-off value)
- - - - - adjust. within meas. range
Hysteresis related to the threshold value
Over- / undervoltage fixed 5 % -
Phase unbalance - - - - - fixed 20 %
Rated frequency of the measuring signal 50/60 Hz
Frequency range of the measuring signal 45-65 Hz
Maximum measuring cycle time 100 ms
Accuracy within the rated control supply voltage tolerance �U � 0.5 %Accuracy within the temperature range �U � 0.06 % / °CMeasuring method True RMS
Timing circuitStart-up delay t
Sfixed 200 ms
Tripping delay tV
ON- or OFF-delay 0; 0.1-30 s adjustable
ON- delay 0; 0.1-30 s adjustable
Repeat accuracy (constant parameters) - - - - < � 0.2 % - -
Accuracy within the rated control supply voltage tolerance �t � 0.5 %Accuracy within the temperature range �t � 0.06 % / °CIndication of operational states 1 yellow LED, 2 red LED's
Details see function description / -diagrams
Details see operating mode and function description / -diagrams
Details see function description / -diagrams
Output circuits 15-16/18, 25-26/28Kind of output relay, 2 x 1 c/o contact
Operating principle closed-circuit principle 1)
Contact material AgNi alloy, Cd free
Rated operational voltage Ue
IEC/EN 60947-1 250 V
Minimum switching power 24 V / 10 mA
Maximum switching voltage see „Load limit curves“ on page 127
1) Closed-circuit principle: Output relay(s) de-energize(s) if measured value exceeds or falls below the adjusted threshold value
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/44
2
Three-phase monitoring relays
Technical data
Type CM-PSS.31 CM-PSS.41 CM-PVS.31 CM-PVS.41 CM-PVS.81 CM-PAS.31 CM-PAS.41Rated operational current I
e
(IEC/EN 60947-5-1)AC-12 (resistive) 230 V 4 A
AC-15 (inductive) 230 V 3 A
DC-12 (resistive) 24 V 4 A
DC-13 (inductive) 24 V 2 A
AC rating (UL 508) Utilization category (Control Circuit Rating Code)
B 300
max. rated operational voltage 300 V AC
max. continuous thermal current at B 300
5 A
max. making/breaking apparent power at B 300
3600/360 VA
Mechanical lifetime 30 x 106 switching cycles
Electrical lifetime (AC-12, 230 V, 4 A) 0.1 x 106 switching cycles
Max. fuse rating to achieve short-circuit protection
n/c contact 6 A fast-acting
n/o contact 10 A fast-acting
General dataMTBF on request
Duty time 100%
Dimensions (W x H x D)
product dimensions 22.5 x 85.6 x 103.7 mm (0.89 x 3.37 x 4.08 in)
packaging dimensions 97 x 109 x 30 mm (3.82 x 4.29 x 1.18 in)
Weight depending on device, see ordering details
Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool
Mounting position any
Minimum distance to other units
horizontal 10 mm (0.39 in) in case of continuous measuring voltages
> 400 V > 400 V > 220 V > 400 V - > 220 V > 400 V
Material of housing UL 94 V-0
Degree of protection housing / terminals IP50 / IP20
Electrical connectionWire size Screw connection technology Easy Connect Technology (Push-in)
fine-strand with(out) wire end ferrule
1 x 0.5-2.5 mm2 (1 x 20-14 AWG)2 x 0.5-1.5 mm2 (2 x 20-16 AWG)
2 x 0.5-1.5 mm2 (2 x 20-16 AWG)
rigid 1 x 0.5-4 mm2 (1 x 20-12 AWG)2 x 0.5-2.5 mm2 (2 x 20-14 AWG)
2 x 0.5-1.5 mm2 (2 x 20-16 AWG)
Stripping length 8 mm (0.32 in)
Tightening torque 0.6-0.8 Nm (5.31-7.08 lb.in) -
Environmental dataAmbient temperature ranges operation / storage -25...+60 °C / -40...+85 °C
Damp heat (IEC 60068-2-30) 55 °C, 6 cycles
Climatic category 3K3
Vibration (sinusoidal) (IEC/EN 60255-21-1) Class 2
Shock (IEC/EN 60255-21-2) Class 2
Isolation dataRated insulation voltage U
i
input circuit / output circuit 600 V
output circuit 1 / output circuit 2 300 V
Rated impulse withstand voltage U
imp (VDE 0110, IEC/EN 60664)
input circuit 6 kV; 1.2/50 μs
output circuit 4 kV; 1.2/50 μs
Test voltage between all isolated circuits (routine test) 2.5 kV, 50 Hz, 1 s
Basic insulation input circuit / output circuit 600 V
Protective separation (VDE 0106 part 101 and 101/A, IEC/EN 1140)
input circuit / output circuit
-
Pollution degree (VDE 0110, IEC/EN 60664) 3
Overvoltage category (VDE 0110, IEC 60664) III
StandardsProduct standard IEC/EN 60255-6, EN 50178
Low Voltage Directive 2006/95/EC
EMC directive 2004/108/EC
RoHS directive 2011/65/EC
Electromagnetic compatibilityInterference immunity to EN 61000-6-1, EN 61000-6-2
electrostatic discharge IEC/EN 61000-4-2 Level 3 (6 kV / 8 kV)
radiated, radio-frequency, electromagnetic field
IEC/EN 61000-4-3 Level 3 (10 V/m)
electrical fast transient / burst
IEC/EN 61000-4-4 Level 3 (2 kV / 2 kHz)
surge IEC/EN 61000-4-5 Level 4 (2 kV L-L)
conducted disturbances, induced by radio-frequency fields
IEC/EN 61000-4-6 Level 3 (10 V)
Interference emission EN 61000-6-3, EN 61000-6-4
high-frequency radiated IEC/CISPR 22, EN 55022 Class B
high-frequency conducted IEC/CISPR 22, EN 55022 Class B
2/45 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Three-phase monitoring relays
Technical data
Type CM-MPS.11 CM-MPS.21 CM-MPS.31 CM-MPS.41
Input circuit = Measuring circuit L1, L2, L3, N L1, L2, L3Rated control supply voltage U
S = measuring voltage 3x90-170 V AC 3x180-280 V AC 3x160-300 V AC 3x300-500 V AC
Rated control supply voltage US tolerance -15...+10 %
Rated frequency 50/60 Hz
Frequency range 45-65 Hz
Typical current / power consumption 25 mA / 10 VA(115 V AC)
25 mA / 18 VA (230 V AC)
25 mA / 10 VA (230 V AC)
25 mA / 18 VA (400 V AC)
Measuring circuit L1, L2, L3, N L1, L2, L3Monitoring functions Phase failure � � � �
Phase sequence can be switched off
Automatic phase sequence correction - - - -
Over- / undervoltage � � � �Phase unbalance � � � �
Interrupted neutral � � - -
Measuring range Overvoltage 3x120-170 V AC 3x240-280 V AC 3x220-300 V AC 3x420-500 V AC
Undervoltage 3x90-130 V AC 3x180-220 V AC 3x160-230 V AC 3x300-380 V AC
Phase unbalance 2-25 % of average of phase voltages
Thresholds Overvoltage adjustable within measuring range
Undervoltage adjustable within measuring range
Phase unbalance (switch-off value) adjustable within measuring range
Hysteresis related to the threshold value
Over- / undervoltage fixed 5 %
Phase unbalance fixed 20 %
Rated frequency of the measuring signal 50/60 Hz
Frequency range of the measuring signal 45-65 Hz
Maximum measuring cycle time 100 ms
Accuracy within the rated control supply voltage tolerance �U � 0.5 %Accuracy within the temperature range �U � 0.06 % / °CMeasuring method True RMS
Timing circuitStart-up delay t
Sfixed 200 ms
Tripping delay tV
ON- or OFF-delay 0; 0.1-30 s adjustable
Accuracy within the rated control supply voltage tolerance �t � 0.5 %Accuracy within the temperature range �t � 0.06 % / °CIndication of operational states Details see function description / -diagrams
Output circuits 15-16/18, 25-26/28
Kind of output relay, 1 x 2 c/o contacts
Operating principle closed-circuit principle 1)
Contact material AgNi alloy, Cd free
Rated operational voltage Ue
(IEC/EN 60947-1) 250 V
Minimum switching power 24 V / 10 mA
Maximum switching voltage see „Load limit curves“ on page 127
Rated operational current Ie
(IEC/EN 60947-5-1)AC-12 (resistive) 230 V 4 A
AC-15 (inductive) 230 V 3 A
DC-12 (resistive) 24 V 4 A
DC-13 (inductive) 24 V 2 A
AC rating (UL 508) Utilization category (Control Circuit Rating Code)
B 300
max. rated operational voltage 300 V AC
max. continuous thermal current at B 300 5 A
max. making/breaking apparent power at B 300
3600/360 VA
Mechanical lifetime 30 x 106 switching cycles
Electrical lifetime (AC-12, 230 V, 4 A) 0.1 x 106 switching cycles
Max. fuse rating to achieve short-circuit protection
n/c contact 6 A fast-acting
n/o contact 10 A fast-acting
1) Closed-circuit principle: Output relay(s) de-energize(s) if measured value exceeds or falls below the adjusted threshold value
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/46
2
Type CM-MPS.11 CM-MPS.21 CM-MPS.31 CM-MPS.41
General dataMTBF on request
Duty time 100%
Dimensions (W x H x D) product dimensions 22.5 x 85.6 x 103.7 mm (0.89 x 3.37 x 4.08 in)
packaging dimensions 97 x 109 x 30 mm (3.82 x 4.29 x 1.18 in)
Weight Screw connection technology Easy Connect Technology (Push-in)net weight depending on device, see ordering details
gross weight depending on device, see ordering details
Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool
Mounting position any
Minimum distance to other units horizontal 10 mm (0.39 in) in case of continuous measuring voltages
> 120 V > 240 V > 220 V > 400 V
Material of housing UL 94 V-0
Degree of protection housing / terminals IP50 / IP20
Electrical connectionWire size Screw connection technology Easy Connect Technology (Push-in)
fine-strand with(out) wire end ferrule 1 x 0.5-2.5 mm2 (1 x 20-14 AWG)2 x 0.5-1.5 mm2 (2 x 20-16 AWG)
2 x 0.5-1.5 mm2 (2 x 20-16 AWG)
rigid 1 x 0.5-4 mm2 (1 x 20-12 AWG)2 x 0.5-2.5 mm2 (2 x 20-14 AWG)
2 x 0.5-1.5 mm2 (2 x 20-16 AWG)
Stripping length 8 mm (0.32 in)
Tightening torque 0.6-0.8 Nm (5.31-7.08 lb.in) -
Environmental dataAmbient temperature ranges operation / storage -25...+60 °C / -40...+85 °C
Damp heat (IEC 60068-2-30) 55 °C, 6 cycles
Climatic category 3K3
Vibration (sinusoidal) (IEC/EN 60255-21-1) Class 2
Shock (IEC/EN 60255-21-2) Class 2
Isolation dataRated insulation voltage U
i
input circuit / output circuit 600 V
output circuit 1 / output circuit 2 300 V
Rated impulse withstand voltage Uimp
(VDE 0110, IEC/EN 60664)
input circuit 6 kV; 1.2/50 μs
output circuit 4 kV; 1.2/50 μs
Test voltage between all isolated circuits (routine test) 2.5 kV, 50 Hz, 1 s
Basic insulation input circuit / output circuit 600 V
Protective separation (VDE 0106 part 101 and 101/A, IEC/EN 61140)
input circuit / output circuit
yes -
Pollution degree (VDE 0110, IEC/EN 60664) 3
Overvoltage category (VDE 0110, IEC 60664) III
StandardsProduct standard IEC/EN 60255-1, EN 50178
Low Voltage Directive 2006/95/EC
EMC directive 2004/108/EC
RoHS directive 2011/65/EC
Electromagnetic compatibilityInterference immunity to EN 61000-6-1, EN 61000-6-2
electrostatic discharge IEC/EN 61000-4-2 Level 3 (6 kV / 8 kV)
radiated, radio-frequency, electromagnetic field
IEC/EN 61000-4-3 Level 3 (10 V/m)
electrical fast transient / burst IEC/EN 61000-4-4 Level 3 (2 kV / 2 kHz)
surge IEC/EN 61000-4-5 Level 4 (2 kV L-L)
conducted disturbances, induced by radio-frequency fields
IEC/EN 61000-4-6 Level 3 (10 V)
harmonics and interharmonics IEC/EN 61000-4-13 Class 3
Interference emission EN 61000-6-3, EN 61000-6-4
high-frequency radiated IEC/CISPR 22, EN 55022 Class B
high-frequency conducted IEC/CISPR 22, EN 55022 Class B
Three-phase monitoring relays
Technical data
2/47 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Three-phase monitoring relays
Technical data
Type CM-MPS.23 CM-MPS.43 CM-MPN.52 CM-MPN.62 CM-MPN.72
Input circuit = Measuring circuit L1, L2, L3, N L1, L2, L3
Rated control supply voltage US = measuring voltage 3x180-280
V AC3x300-500 V AC
3x350-580 V AC
3x450-720 V AC
3x530-820 V AC
Rated control supply voltage US tolerance -15...+10 %
Rated frequency 50/60/400 Hz 50/60 HzFrequency range 45-440 Hz 45-65 HzTypical current / power consumption 5 mA / 4 VA
(230 V AC)5 mA / 4 VA (400 V AC)
29 mA / 41 VA (480 V AC)
29 mA / 52 VA (600 V AC)
29 mA / 59 VA (690 V AC)
Measuring circuit L1, L2, L3, N L1, L2, L3Monitoring functions Phase failure � � � � �
Phase sequence can be switched offAutomatic phase sequence correction configurable
Over- / undervoltage � � � � �Phase unbalance � � � � �
Interrupted neutral � - - - -
Measuring range Overvoltage 3x240-280 V AC
3x420-500 V AC
3x480-580 V AC
3x600-720 V AC
3x690-820 V AC
Undervoltage 3x180-220 V AC
3x300-380 V AC
3x350-460 V AC
3x450-570 V AC
3x530-660 V AC
Phase unbalance 2-25 % of average of phase voltagesThresholds Overvoltage adjustable within measuring range
Undervoltage adjustable within measuring rangePhase unbalance (switch-off value) adjustable within measuring range
Hysteresis related to the threshold value
Over- / undervoltage fixed 5 %Phase unbalance fixed 20 %
Rated frequency of the measuring signal 50/60/400 Hz 50/60 HzFrequency range of the measuring signal 45-440 Hz 45-65 HzMaximum measuring cycle time 100 msAccuracy within the rated control supply voltage tolerance �U � 0.5 %Accuracy within the temperature range �U � 0.06 % / °CMeasuring method True RMS
Timing circuitStart-up delay t
S and t
S2fixed 200 ms
Start-up delay tS1
fixed 250 ms
Tripping delay tV
ON- or OFF-delay 0; 0.1-30 s adjustable
Accuracy within the rated control supply voltage tolerance �t � 0.5 %Accuracy within the temperature range �t � 0.06 % / °CIndication of operational states Details see function description / -diagrams
Output circuits 15-16/18, 25-26/28Kind of output relay, 2 x 1 or 1 x 2 c/o contacts configurableOperating principle closed-circuit principle 1)
Contact material AgNi alloy, Cd freeRated operational voltage U
e IEC/EN 60947-1 250 V
Minimum switching power 24 V / 10 mAMaximum switching voltage see „Load limit curves“ on page 127Rated operational current I
e
(IEC/EN 60947-5-1)AC-12 (resistive) 230 V 4 A
AC-15 (inductive) 230 V 3 ADC-12 (resistive) 24 V 4 A
DC-13 (inductive) 24 V 2 AAC rating (UL 508) Utilization category
(Control Circuit Rating Code)B 300
max. rated operational voltage 300 V ACmax. continuous thermal current at B 300 5 A
max. making/breaking apparent power at B 300 3600/360 VAMechanical lifetime 30 x 106 switching cyclesElectrical lifetime (AC-12, 230 V, 4 A) 0,1 x 106 switching cyclesMax. fuse rating to achieve short-circuit protection
n/c contact 6 A fast-acting 10 A fast-actingn/o contact 10 A fast-acting
1) Closed-circuit principle: Output relay(s) de-energize(s) if measured value exceeds or falls below the adjusted threshold value
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/48
2
Three-phase monitoring relays
Technical data
Type CM-MPS.23 CM-MPS.43 CM-MPN.52 CM-MPN.62 CM-MPN.72
General dataMTBF on requestDuty time 100%Dimensions (W x H x D) product dimensions 22.5 x 85.6 x 103.7 mm (0.89 x 3.37 x 4.08 in)
packaging dimensions 97 x 109 x 30 mm (3.82 x 4.29 x 1.18 in)Weight depending on device, see ordering detailsMounting DIN rail (IEC/EN 60715), snap-on mounting without any toolMounting position anyMinimum distance to other units vertical / horizontal not necessary / not necessaryMaterial of housing UL 94 V-0Degree of protection housing / terminals IP50 / IP20
Electrical connectionWire size Screw connection technology Easy Connect Technology (Push-in)
fine-strand with(out) wire end ferrule 1 x 0.5-2.5 mm2 (1 x 20-14 AWG)2 x 0.5-1.5 mm2 (2 x 20-16 AWG)
2 x 0.5-1.5 mm2 (2 x 20-16 AWG)
rigid 1 x 0.5-4 mm2 (1 x 20-12 AWG)2 x 0.5-2.5 mm2 (2 x 20-14 AWG)
2 x 0.5-1.5 mm2 (2 x 20-16 AWG)
Stripping length 8 mm (0.32 in)Tightening torque 0.6-0.8 Nm (5.31-7.08 lb.in) -
Environmental dataAmbient temperature ranges operation / storage -25...+60 °C / -40...+85 °CDamp heat (IEC 60068-2-30) 55 °C, 6 cyclesClimatic category 3K3Vibration (sinusoidal) (IEC/EN 60255-21-1) Class 2Shock (IEC/EN 60255-21-2) Class 2
Isolation dataRated insulation voltage U
iinput circuit / output
circuit600 V 1000 V
output circuit 1 / 2 300 VRated impulse withstand voltage U
imp
(VDE 0110, IEC/EN 60664)input circuit 6 kV; 1.2/50 μs 8 kV; 1.2/50 μs
output circuit 4 kV; 1.2/50 μs
Test voltage (routine test) between
isolated output circuits 2.5 kV, 50 Hz, 1 sinput circuit and isolated output circuits 2.5 kV, 50 Hz, 1 s 4 kV, 50 Hz, 1 s
Basic insulation input circuit / output circuit 600 V 1000 VProtective separation (VDE 0106 part 101 and 101/A, IEC/EN 61140)
input circuit / output circuit
-
Pollution degree (VDE 0110, IEC/EN 60664) 3Overvoltage category (VDE 0110, IEC 60664) III
StandardsProduct standard IEC/EN 60255-1, EN 50178Low Voltage Directive 2006/95/ECEMC directive 2004/108/ECRoHS directive 2011/65/EC
Electromagnetic compatibilityInterference immunity to EN 61000-6-1, EN 61000-6-2
electrostatic discharge IEC/EN 61000-4-2 Level 3 (6 kV / 8 kV)radiated, radio-frequency, electromagnetic field
IEC/EN 61000-4-3 Level 3 (10 V/m)
electrical fast transient / burst IEC/EN 61000-4-4 Level 3 (2 kV / 2 kHz)surge IEC/EN 61000-4-5 Level 4 (2 kV
L-N)Level 4 (2 kV L-L)
conducted disturbances, induced by radio-frequency fields
IEC/EN 61000-4-6 Level 3 (10 V)
harmonics and interharmonics IEC/EN 61000-4-13 Class 3Interference emission EN 61000-6-3, EN 61000-6-4
high-frequency radiated IEC/CISPR 22, EN 55022 Class Bhigh-frequency conducted IEC/CISPR 22, EN 55022 Class B
2/49 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Grid feeding monitoring relays -
Voltage and frequency monitoring functions
Product group picture
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/50
2
Grid feeding monitoring relays -
Voltage and frequency monitoring functions
Table of contents
Grid feeding monitoring relays - Voltage and frequency monitoring functions
Benefits and advantages, operating controls 2/51
Applications 2/52
Applications, connection diagram 2/53
Ordering and selection 2/54
Technical data - CM-UFD.Mxx 2/55
2/51 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Grid feeding monitoring relays -
Voltage and frequency monitoring functions
Benefits and advantages, operating controls
Characteristics for all CM-UFD devices – Monitoring of voltage and frequency in single- and three-
phase mains 2-wire, 3-wire or 4-wire
– Over- and undervoltage, 10 minutes average value as well
as over- and underfrequency monitoring
– Two-level threshold settings for over-/undervoltage and
frequency
– Multiline, backlit LCD display
– All threshold values adjustable as absolute values
– True RMS measuring principle
– High measurement accuracy
– 3 control inputs for remote trip, feedback signal, and
external signal
– Interrupted neutral detection
– Error memory for up to 99 entries (incl. cause of error,
measured value, relative timestamp)
– Test function
– Password setting protection
– 3 c/o (SPDT) contacts
– LEDs for the indication of operational states
Characteristics CM-UFD.M22 – ROCOF (rate of change of frequency) monitoring, configurable
– Third party certificate confirming accordance with CEI 0-21
– Pre-setting according to CEI 0-21
Characteristics CM-UFD.M31 – ROCOF (rate of change of frequency) monitoring and vec-
tor shift detection, configurable
– Third party certificate confirming accordance with
VDE-AR-N 4105 and BDEW
– Pre-settings according to VDE-AR-N 4105 and BDEW
Characteristics CM-UFD.M33 – ROCOF (rate of change of frequency) monitoring and vec-
tor shift detection, configurable
– Factory certificate confirming accordance with Engineering
Recommendation G59 Issue 3 - September 2013; Engi-
neering Recommendation G83 Issue 2 - December 2012
– Pre-setting according to G59/3 LV + G83/2 HV
– UL 508, CAN/CSA C22.2 No.14
1
2
3
1 Display R1 R2 R3 - relay status; in this case R3 is de-energized
FB - status feedback loop Y0-Y1; in this case FB is closed
EXT – status input external signal; in this case input is closed
REM – status remote trip input; in this case input is closed
2 Indication of operational states U/T: green LED – supply voltage applied / flashing = timing active
F: red LED - failure
3 Keypad ESC: escape / return to previous menu
^: up / value increase
: down / value decrease
OK: enter / confirm selection
CM-UFD.Mxx
2C
DC
25
3 0
20
F0
01
3
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/52
2
Grid feeding monitoring relays -
Voltage and frequency monitoring functions
Applications
Example of single-phase application - CM-UFD.M31
L1
N
K1
�6 A
�10 A �10 A �10 A
K2
� �
��
���Y0Y23438 Y332362428222614181216 Y1
A2A1 21251115 3135 L3L2L1 N
Public grid
Inverter(s)Generator(s)
� Control input 1, feedback loop for switching device 1
� Control input 2, feedback loop for switching device 2
� Control input 3 (e.g. for remote trip)
� Switching device 1 of the section switch
� Switching device 2 of the section switch
where applicable, a transformer
2C
DC
25
2 0
06
F0
21
3
Example of three-phase application - CM-UFD.M31
L1
L2L3
N
K1
�6 A
K2
� �
��
���Y0Y23438 Y332362428222614181216 Y1
A2A1 21251115 3135 L3L2L1 N
Public grid
Inverter(s)Generator(s)
� Control input 1, feedback loop for switching device 1
� Control input 2, feedback loop for switching device 2
� Control input 3 (e.g. for remote trip)
� Switching device 1 of the section switch
� Switching device 2 of the section switch
where applicable, a transformer
2C
DC
25
2 0
07
F0
21
3
Example of three-phase application CM-UFD.M22
A1
14 11 12 24 21 22 34 31 32
18 15 16 28 25 26 38 35 36
A2 Y1 L1 L2 L3 NY2 Y3 Y0
ESC
OK
CM-UFD
U/TF
230 V AC
24 V DC
24 V DC
L N
L1 N
L+
L+IN L-IN
L+OUTL-OUT
L-
CP-E 24/X
CP-B 24/X
L1 L2 L3 N
G
1
8
7
9
11
12
13
10
4
23
6
Example of single-phase application CM-UFD.M22
A1
14 11 12 24 21 22 34 31 32
18 15 16 28 25 26 38 35 36
A2 Y1 L1 L2 L3 NY2 Y3 Y0
ESC
OK
CM-UFD
U/TF
230 V AC
24 V DC
24 V DC
L N L N
L1 N
L+
L+IN L-IN
L+OUTL-OUT
L-
CP-E 24/X
CP-B 24/X
G
13
12
11
9
7
10
1
4
23
6
5
2C
DC
25
2 0
04
F0
01
4
2C
DC
25
2 0
03
F0
01
4
1. Main circuit breaker DG or DGL
2. DDI: Automatic circuit breaker or contactor equipped with low voltage coil and
motor for automatic closure
3. Auxiliary contact of DDI, necessary for realizing the feedback function (compul-
sory for CM-UFD.M22)
4. DDI short-circuit protection
5. Generator and/or inverter
6. Generator (DDG)
7. Protection fuse for the measuring circuit of the CM-UFD.M22 (optional)
8. Shunt trip coil for feedback function (P>20 kW). This coil can control DG/DGL or
DDG devices
9. Control supply voltage for CM-UFD.M22 (SPI) and tripping device (DDI)*
10. Device protection fuse for the CM-UFD.M22
11. Primary switch mode power supply unit CP-E (230 V AC / 24 V DC) for the buf-
fer module CP-B*
12. Ultra-capacitor based buffer module CP-B (24 V DC in/out)
13. Wire protection fuse for the output of the buffer module CP-B* In accordance to CEI 0-21 regulation, in case of loss of control supply voltage it’s asked to guarantee, at least for 5 seconds, the functionality
of the CM-UFD.M22, the operability of the DDI and when present the command coil for operating the redundancy device. This function has to
be realized by external buffer or UPS devices.
2/53 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Grid feeding monitoring relays -
Voltage and frequency monitoring functions
Applications, connection diagram
Example of single-phase application - CM-UFD.M33
L1
N
K1
�6 A
�10 A �10 A �10 A
K2
Y0Y23438 Y332362428222614181216 Y1
A2A1 21251115 3135 L3L2L1 N
2C
DC
25
2 0
05
F0
01
4
Example of three-phase application - CM-UFD.M33
L1
L2L3
N
K1
�6 A
K2
�10 A �10 A �10 A
Y0Y23438 Y332362428222614181216 Y1
A2A1 21251115 3135 L3L2L1 N
2C
DC
25
2 0
06
F0
01
4
� Control input 1, feedback loop for switching device 1
� Control input 2, feedback loop for switching device 2
� Control input 3 (e.g. for remote trip)
Switching device 1 of the section switch
Switching device 2 of the section switch
� Inverter(s) / generator(s)
� Transformer (if applicable)
Public grid
� Control input 1, feedback loop for switching device 1
� Control input 2, feedback loop for switching device 2
� Control input 3 (e.g. for remote trip)
Switching device 1 of the section switch
Switching device 2 of the section switch
� Inverter(s) / generator(s)
� Transformer (if applicable)
Public grid
�
�
�
�
�
�
�
�
�
�
�
�
�
A1 A2 Y1 Y2 Y3 Y0 L1 L2 L3 N
24 21 22121114
28 25 26 38 35 36161518
CM-UFD
U/T
F
34 31 32
ESC
OK
Test
2C
DC
25
3 0
07
F0
01
4 A1-A2L1, L2, L3, NY1-Y0Y2-Y0Y3-Y0
1115
-1216
/1418
2125
-2226
/2428
3135
-3236
/3438
Control supply voltage Us
Measuring inputsControl input 1: Feedback from switching device 1Control input 2: Feedback from switching device 2Control input 3: Remote trip, suppress Y1, suppress Y2, suppress Y1/Y2 or suppress vector shift detectionOutput relay 1: Relay for tripping switching device 1 of the section switch, closed-circuit principleOutput relay 2: Relay for tripping switching device 2 of the section switch, closed-circuit principleOutput relay 3: Closing command for circuit breaker motor, configuration possibilities: closed-circuit principle, open-circuit principle, disabled or synchronous with R1/R2
Electrical connection - CM-UFD.Mxx
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/54
2
2C
DC
25
1 0
05
S0
01
3
CM-UFD.Mxx
Grid feeding monitoring relays -
Voltage and frequency monitoring functions
Ordering and selection
Description
Only reliable and continuous monitoring of a three-phase network guarantees the trouble-free
and economic operation of machines and installations.
Ordering detailsRated control supply voltage = measuring voltage
Type Order code Price
1 pce
Weight(1 pce)kg (lb)
24-240 V AC/DC CM-UFD.M22 1SVR560730R34000.225 (0.496)
24-240 V AC/DC CM-UFD.M31 1SVR560730R34010.225 (0.496)
24-240 V AC/DC CM-UFD.M33 1SVR560730R34020.304 (0.670)
Ord
er n
um
ber
1S
VR
56
07
30
R3
40
0
1S
VR
56
07
30
R3
40
1
1S
VR
56
07
30
R3
40
2
Typ
e
CM
-UF
D.M
22
CM
-UF
D.M
31
CM
-UF
D.M
33
Rated control supply voltage Us
24-240 V AC/DC � � �Standard
VDE AR-N 4105, BDEW �G59/3 �CEI 0-21 �Rated frequencyDC or 50 Hz � �DC or 50/60 Hz �Suitable for monitoring
Single-phase mains � � �
Three-phase mains � � �
Monitoring function
Over-/undervoltage � � �
Over-/underfrequency � � �
ROCOF (rate of change of frequency) � � �
10 minutes average value � � �
Vector shift � �
Thresholds adj adj adj
2/55 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Grid feeding monitoring relays -
Voltage and frequency monitoring functions
Technical data - CM-UFD.Mxx
Technical dataData at Ta = 25 °C and rated values, unless otherwise indicated
Type CM-UFD.M22 CM-UFD.M31 CM-UFD.M33
Input circuit - Supply circuitRated control supply voltage U
s 24-240 V AC/DC
Rated control supply voltage Us tolerance -15…+10 %
Rated frequency DC or 50 Hz DC or 50/60 Hz
Frequency range AC 40-60 Hz 40-70 Hz
Typical current / power consumption 24 V DC 64 mA / 1.5 W
230 V AC 6.4 mA / 1.5 VA
External fusing (necessary) 6 A gG (gL) or cirucit breaker 6 A with B characteristic or 6 A Class CC (acc. to UL-requirements)
Power failure buffering time 200 ms, according to LVFRT (Low Voltage Fault Ride Through)
Measuring circuitMonitoring functions overvoltage 10-min average (>UAV) adjustable,
1.00-1.30 * Us
in 0.01*Us steps
threshold adjustable, 1.000-1.300 * Un
in 0.005 * Un steps
overvoltage (>U1) adjustable, 1.00-1.20 * U
s
in 0.01*Us steps
threshold adjustable, 1.000-1.300 * Un
in 0.005 * Un steps
overvoltage (>U2) - threshold adjustable, 1.000-1.300 * Un
in 0.005 * Un steps
undervoltage (<U1) adjustable, 0.05-1.00 * U
s
in 0.01*Us steps
threshold adjustable, 0.100-1.000 * Un
in 0.005 * Un steps
undervoltage (<U2) adjustable, 0.05-1.00 * U
s
in 0.01*Us steps
threshold adjustable, 0.100-1.000 * Un
in 0.005 * Un steps
overfrequency (>F1) adjustable, 50.0-54.0 Hz in 0.1 Hz steps
threshold adjustable, 50.00-65.00 Hz in 0.01 Hz steps
underfrequency (<F2) adjustable, 46.0-50.0 Hz in 0.1 Hz steps
threshold adjustable, 50.00-65.00 Hz in 0.01 Hz steps
overfrequency (>F1) adjustable, 50.0-54.0 Hz in 0.1 Hz steps
threshold adjustable, 45.00-60.00 Hz in 0.01 Hz steps
underfrequency (<F2) adjustable, 46.0-50.0 Hz in 0.1 Hz steps
threshold adjustable, 45.00-60.00 Hz in 0.01 Hz steps
ROCOF adjustable, 0.1-1.0 Hz/s, in 0.1 Hz/s steps
threshold adjustable, 0.100-5.000 Hz in 0.005 Hz steps
vector shift threshold adjustable, 2.0-40.0 ° in 0.1 ° steps
interrupted neutral conductor enabled if a measuring principle with interrupted neutral conductor is selected
Measuring ranges voltage (4-wire system L1, L2, L3-N) 0-312 V AC 0-317 V AC
(3-wire system L1,L2,L3) 0-540 V AC 0-550 V AC
(2-wire system L-N) 0-312 V AC 0-317 V AC
frequency 40-60 Hz 40-70 Hz
Rated frequency of the measuring signal 50 Hz 50/60 Hz
Accuracy of measurements voltage ≤ 2 % ≤ 0.5 % ± 0.5 V
frequency ± 20 mHz ± 20 mHz
delay times ≤ 5 % ± 20 ms ≤ 0.1 % ± 20 ms
Accuracy within the temperature range ΔU ≤ 0.02 %/°C
Hysteresis related to the threshold value
overvoltage 10-min average - adjustable, 0.1-10.0 % in 0.1 % steps
overvoltage 0.95-0.97 * Us
adjustable, 0.5-10.0 % in 0.1 % steps
undervoltage 1.03-1.05 * Us
adjustable, 0.5-10.0 % in 0.1 % steps
overfrequency 0.997-0.999 * fn
adjustable, 0.05-4.00 Hz in 0.01 Hz steps
underfrequency 1.001-1.003 * fn
adjustable, 0.05-4.00 Hz in 0.01 Hz steps
Reaction time acc. CEI 0-21 chapter A.4.3 CM-UFD.M22: adjustable, 0.05-600.00 s in 0.05 s steps, ±3 % ±20 ms for: Overvoltage 2, Undervoltage 1, Undervoltage 2, Overfrequency 1, Overfrequency 2, Underfrequency 1, Underfrequency 2
Measuring cycle ROCOF 640 ms at 50 Hz adjustable, 4-50 periods
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/56
2
Grid feeding monitoring relays -
Voltage and frequency monitoring functions
Technical data - CM-UFD.Mxx
Type CM-UFD.M22 CM-UFD.M31 CM-UFD.M33
Control circuitsNumber 3
Type of triggering volt-free triggering, signal source Y0
Function of the control inputs Y1-Y0 Control input 1 DDI feedback, trip and release monitoring times adjustable
feedback from switching device 1
Y2-Y0 Control input 2 External signal feedback from switching device 2
Y3-Y0 Control input 3 Remote trip remote trip; suppression of Y1, Y2, Y1/Y2 or vector shift detect.
Electrical isolation from supply voltage yes
from the measuring circuit no
from the relay outputs yes
Max. switching current in the control circuit 6 mA
No-load voltage at the control inputs (V0-V1, V2, V3) 22-26 V DC
Minimum control pulse length 20 ms
Max. cable length at the control inputs (unshielded) 10 m
Timing functionsStart-up delay, R1 (prior to first grid connection or re-connection after interruption)
adjustable, 1.00-600.00 s in 0.05 s steps
-
Restart delay, R1 adjustable, 0.05-600.00 s in 0.05 s steps
-
Start-up delay, R2 (prior to first grid connection or re-connection after interruption)
1 s, fixed -
ON-delay, R3 adjustable, 0.00-10.00 s in 0.05 s steps
-
ON-time, R3 adjustable, 0.05-10.00 s in 0.05 s steps
-
Trip window, feedback loop Y1 adjustable, 0.05-0.50 s in 0.05 s steps
-
Release window, feedback loop Y1 adjustable, 0.50-600.00 s in 0.05 s steps
-
Tripping delays adjustable, 0.05-600.00 s in 0.05 s steps
-
ROCOF error time -
Switch-on delay (prior to first grid connection or reconnection after interruption)
- adjustable, 0.05-600.00 s in 0.01 s steps
Tripping delay overvoltage 10-min average (>UAV
) - < 3 s
overvoltage (>U1, >U2) - adjustable, 0.00-600.00 s in 0.01 s steps; +50 ms / -0 msundervoltage (<U1, <U2)
overfrequency (>F1, >F2)
underfrequency (<F1, <F2)
ROCOF
vector shift - < 50 ms
interrupted neutral conductor < 150 ms
Error time ROCOF - adjustable, 0.5-600.00s in 0.01 s steps
vector shift - adjustable, 0.5-600.00s in 0.01 s steps
Trip window (feedback loops Y1-Y0, Y2-Y0) - adjustable, 0.05-0.50 s in 0.01 s steps
Release window (feedback loops Y1-Y0, Y2-Y0) - adjustable, 0.50-600.00 s in 0.01 s steps
Time error within the temperature range - Δt ≤ 0.01 %
User interface - Indication of operational statesControl supply voltage applied / timing U/T LED green on / flashing
Fault message F LED red on
For details see the message on the display
User interface - DisplayBack light on press any button
off switch-off delay adjustable, 10-600 s (default 10 s)
Operating temperature range of the display clearly visible -20…+60 °C
Resolution 112 x 64 pixel
Display size 36 x 22 mm
User interface - Operating elements4 push-buttons for menu navigation, setting and entering
2/57 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Grid feeding monitoring relays -
Voltage and frequency monitoring functions
Technical data - CM-UFD.Mxx
Type CM-UFD.M22 CM-UFD.M31 CM-UFD.M33
Output circuitsKind of outputs 11-12/14 (15-16/18) 1st c/o (SPDT) contact, tripping relay for switching device 1 (DDI)
21-22/24 (25-26/28) 2nd c/o (SPDT) contact, tripping relay for switching device 2 (DG)
31-32/34 (35-36/38) 3rd c/o (SPDT) contact, closing command for breaker motor
Operating principle 11-12/14 closed-circuit principle
21-22/24 open- or closed-circuit principle configurable
closed-circuit principle
31-32/34 open-circuit, closed-circuit, disabled or synchronous with R1/R2 configurable
Contact material AgNi alloy, Cd-free
Rated operational voltage Ue
IEC/EN 60947-1 250 V 300 V
Minimum switching voltage / minimum switching current 24 V / 10 mA
Maximum switching voltage / maximum switching current see load limit curves
Rated operational current Ie
(IEC/EN 60947-5-1)AC-12 (resisitive) at 230 V 4 A
AC-15 (inductive) at 230 V 3 A
DC-12 (resistive) at 24 V 4 A
DC-13 (inductive) at 24 V 2 A
Mechanical lifetime 30 x 106 switching cycles
Electrical lifetime at AC12, 230 V AC, 4 A 50 x 103 switching cycles
Maximum fuse rating to achieve short-circuit protection n/c contact 10 A fast-acting 10 A fast-acting or circuit breaker 10 A with B characteristic
n/o contact 10 A fast-acting 10 A fast-acting or circuit breaker 10 A with B characteristic
Maximum closing current (short time) t < 20 ms 30 A
t < 80 ms 17 AConventional thermal current I
th IEC/EN 60947-1 5 A
General dataMTBF on request
Repeat accuracy (constant parameters) < ±0.5 %
Duty time 100 %
Dimensions (W x H x D) product dimensions 108 x 90 x 67 mm (4.25 x 3.54 x 2.64 in)
packaging dimensions 121 x 99 x 71 mm (4.76 x 3.90 x 2.80 in)
Weight net weight 0.306 kg (0.675 lb)
gross weight 0.360 kg (0.794 lb)
Material of housing PA666FR
Mounting DIN rail (IEC/EN 60715) TH 35-7.5 and TH 35-15, snap-on mounting without any tool
Mounting position any
Minimum distance to other units horizontal / vertical not necessary
Degree of protection housing / terminals IP20
Electrical connectionWire size fine-strand with wire end ferrulle 1 x 0.25-4 mm² (1 x 24-12 AWG), 2 x 0.25-0.75 mm² (2 x 24-18 AWG)
fine-strand without wire end ferrule 1 x 0.2-4 mm² (1 x 24-12 AWG), 2 x 0.2-1.5 mm² (2 x 24-16 AWG)
rigid 1 x 0.2-6 mm² (1 x 24-10 AWG), 2 x 0.2-1.5 mm² (2 x 24-16 AWG)
Stripping length 8 mm (0.31 in)
Tightening torque 0.5-0.6 Nm (4.4 -5.3 lb.in)
Environmental dataAmbient temperature ranges operation -20...+60 °C
storage -20...+80 °C
Climatic class (EN 50178) 3K5 (w/o condensation, w/o icing)
Damp heat, cyclic (IEC/EN 60068-2-30) 6 x 24 h cycle, 55 °C, 95 % RH
Vibration, sinusoidal (IEC/EN 60255-21-1) Class 2
Shock (IEC/EN 60255-21-2) Class 2
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/58
2
Grid feeding monitoring relays -
Voltage and frequency monitoring functions
Technical data - CM-UFD.Mxx
Type CM-UFD.M22 CM-UFD.M31 CM-UFD.M33
Isolation dataRated insulation voltage U
i
(IEC/EN 60947-1, IEC/EN 60664-1)supply/measuring/output circuits 600 V
output 1/output 2/output 3 300 V
Rated impulse withstand voltage Uimp
(IEC/EN 60947-1, IEC/EN 60664-1)
supply/measuring/output circuits 6 kV; 1.2/50 μs
output 1/output 2/output 3 4 kV; 1.2/50 μs
Basic insulation acc. rated control supply voltage (IEC/EN 60664-1)
supply/measuring/output circuits 600 V
output 1/output 2/output 3 300 V
Protective separation acc. rated voltage (IEC/EN 61140)
supply/measuring/output circuits 250 V
output 1/output 2/output 3 250 V
Test voltage, routine test (IEC/EN 60255-5)
supply/measuring/output circuits 2.2 kV, 50 Hz, 1 s
output 1/output 2/output 3 2.2 kV, 50 Hz, 1 s
Test voltage, type test (CEI 0-21) supply/measuring /output circuits 5 kV, 50 Hz, 1 s -
output 1/output 2/output 3 4 kV, 50 Hz, 1 s -
Pollution degree (IEC/EN 60664-1) 3
Overvoltage category (IEC/EN 60664-1) III
Overvoltage category according to CEI 0-21 IV -
StandardProduct standard IEC/EN 60255-1
Electrical safety - - UL 508, CAN/CSA C22.2 No.14
Application standards CEI 0-21: 2012-06 + CEI 0-21; V1: 2012-12 + A70 Terna
VDE-AR-N 4105: 2011-08;BDEW, June 2008 “Technische Richtlinie – Erzeugungsanlagen am Mittelspannungsnetz” including supplementary provisions of January 2013
Engineering Recommendation G59 Issue 3 - September 2013;Engineering Recommendation G83 Issue 2 - December 2012
Low Voltage Directive 2006/95/EC
EMC Directive 2004/108/EC
RoHS Directive 2011/65/EC
Electromagnetic compatibilityInterference immunity to IEC/EN 61000-6-1, IEC/EN 61000-6-2
electrostatic discharge IEC/EN 61000-4-2 Level 3 (6 kV / 8 kV)
radiated, radio-frequency, electromagnetic field
IEC/EN 61000-4-3 Level 3, 10 V/m
electrical fast transient/burst IEC/EN 61000-4-4 Level 3, 2 kV / 5 kHz
surge IEC/EN 61000-4-5 Level 3, installation class 3, supply andmeasuring input 1 kV L-L, 2 kV L-earth
conducted disturbances, induced by radio- frequency fields
IEC/EN 61000-4-6 Level 3, 10 V
voltage dips, short interruptions and voltage variations
IEC/EN 61000-4-11 Class 3
harmonics and interharmonics IEC/EN 61000-4-13 Class 3
Interference emission IEC/EN 61000-6-3, IEC/EN 61000-6-4
high-frequency radiated IEC/CISPR 22, EN 55022 Class B
high-frequency conducted IEC/CISPR 22, EN 55022 Class B
2/59 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Insulation monitoring relays for unearthed supply systems
Product group picture
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/60
2
Insulation monitoring relays for unearthed supply systems
Table of contents
Insulation monitoring relays for unearthed supply systems
Benefits and advantages 2/61
Benefits and advantages, Applications 2/62
Operating controls 2/63
Insulation monitoring in IT systems 2/64
Selection table 2/65
Ordering details 2/66
Operating state indication, Connection diagrams, DIP switches 2/67
Technical data 2/68
Technical data CM-IVN 2/71
2/61 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Insulation monitoring relays for unearthed supply systems
Benefits and advantages
Insulation monitoring relays for unearthed pure AC systems:
Characteristics – For monitoring the insulation resistance of unearthed IT
systems:
up to Un = 400 V AC
– According to IEC/EN 61557-8 "Electrical safety in low volt-
age distribution systems up to 1000 V AC and 1500 V DC:
Equipment for testing, measuring or monitoring of protec-
tive measures – Part 8: Insulation monitoring devices for IT
systems"
– Rated control supply voltage 24–240 V AC/DC
– Superimposed DC signal
– One measuring range 1–100 k
– Precise adjustment of the threshold value in 1 k steps
– Interrupted wire detection
– Fault storage/latching configurable by control input
– 1 c/o (SPDT) contact, closed-circuit principle
– 22.5 mm [0.89 in] width
– 3 LEDs for status indication
Characteristics – For monitoring the insulation resistance of unearthed IT
systems up to Un= 250 V AC and 300 V DC or U
n= 400 V
AC and 600 V DC
– According to IEC/EN 61557-8 "Electrical safety in low volt-
age distribution systems up to 1000 V AC and 1500 V DC:
Equipment for testing, measuring or monitoring of protec-
tive measures – Part 8: Insulation monitoring devices for IT
systems"1)
– CM-IWN.4,5,6: Specifically for applications with high
system leakage capacitances, for example in photovoltaic
environments
– Rated control supply voltage 24-240 V AC/DC
– Prognostic measuring principle with superimposed square
wave signal
– 1 or 2 measuring ranges (1-100 k or 1-100 k + 2-200 k )
– 1 or 2 (configurable) c/o contacts1)
– Precise adjustmemt of the measuring value in 1 or 2 k steps
– (non-volatile) fault storage, configurable latching, interrupted
wire protection, open- or closed-circuit principle selectable1)
– 22.5 or 45 mm width
– 3 LEDs for status indication1) depending on devices
Additional characteristics for CM-IWN.1,4,5,6: – One (1 x 2 c/o) or two (2 x 1 c/o) threshold values R
an1/R11)
(final switch-off) and Ran
2/R22) (prewarning) configurable3)
– Precise adjustment of the threshold values in 1 kΩ steps
(R1) and 2 kΩ steps (R2)
– Interrupted wire detection configurable
– Non-volatile fault storage configurable
– Open- or closed-circuit principle configurable1) CM-IWN.6 does not meet the requirements of IEC/EN 61557-8 regarding the
response time tan
.2) term acc. to IEC/EN 61557-83) R2 only active with 2 x 1 c/o configuration
Insulation monitoring relays for unearthed AC, DC or mixed AC/DC systems:
2C
DC
25
1 0
17
V0
01
2
2C
DC
25
1 0
09
V0
01
2
2C
DC
25
1 0
20
V0
01
2
CM-IWS.2 CM-IWS.1 CM-IWN.1
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/62
2
Insulation monitoring relays for unearthed supply systems
Benefits and advantages, Applications
Application / monitoring function CM-IWxThe CM-IWx serve to monitor insulation resistance in accor-
dance with IEC 61557-8 in unearthed IT AC systems, IT AC
sytems with galvanically connected DC circuits, or unearthed
IT DC systems. The insulation resistance between system
lines and system earth is measured. If this falls below the
adjustable threshold values, the output relay(s) energize or de-
energize. The CM-IWS.x can monitor control circuits (single-
phase) and main circuits (3-phase). Supply systems with volt-
ages Un= 0-400 V AC (45-65 Hz), U
n=0-250 V AC (15-400 Hz)
or 0-300 V DC can be directly connected. For systems with
voltages above 400 V AC the insulation monitoring relay with
or without the coupling unit CM-IVN can be used.
Application / monitoring function CM-IWN.xThe CM-IWN.x serves to monitor insulation resistance in
accordance with IEC 61557-8 in unearthed IT AC systems,
IT AC systems with galvanically connected DC circuits, or
unearthed IT DC systems. The insulation resistance between
system lines and system earth is measured. If this falls below
the adjustable threshold values, the output relays switch into
the fault state. The device can monitor control circuits (single-
phase) and main circuits (3-phase). Supply systems with
voltages Un = 0-400 V AC (15-400 Hz) or 0-600 V DC can be
directly connected to the measuring inputs and their insulation
resistance being monitored. For systems with voltages above
400 V AC and 600 V DC the coupling unit CM-IVN can be
used for the expansion of the CM-IWN.x voltage range.
Expansion of assortment for the requirements of decentral eletrical energy sourcesABB‘s insulation monitoring relays from the CM-IWN range
provide higher system leakage capacitances which are neces-
sary especially for solar applications. This expanded product
range covers the requirements of decentral eletrical sources
(e.g. photovoltaic systems).
The range of system leakage capacitances is 20 - 2000 μF.
Application / monitoring function CM-IVNThe coupling unit CM-IVN is designed to extend the nominal
voltage range of the insulation monitoring relay CM-IWN.1
up to 690 V AC and 1000 V DC. The coupling unit can be
connected to the system to be monitored by means of the
terminals VL+ and VL-. The terminal Vw has to be connected
to the earth potential. The terminals L+, V1+, L-, V1-, VS and
VE have to be connected to the CM-IWN.1 as shown in the
connection diagrams below. Supply systems with voltages Un
= 0-690 V AC (15-400 Hz) or 0-1000 V DC can be connected.
Measuring principle CM-IWS.2A superimposed DC measuring signal is used for measure-
ment. From the superimposed DC measuring voltage and its
resultant current the value of the insulation resistance of the
system to be monitored is calculated.
Measuring principle CM-IWN.x, CM-IWS.1A pulsating measuring signal is fed into the system to be
monitored and the insulation resistance is calculated. This
pulsating measuring signal alters its form depending on the
insulation resistance and system leakage capacitance. From
this altered form the change in the insulation resistance is
forecast. When the forecast insulation resistance corresponds
to the insulation resistance calculated in the next measure-
ment cycle and is smaller than the set threshold value, the
output relay de-energizes. This measuring princiiple is also
suitable for the detection of symmetrical insulation faults.
2/63 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Insulation monitoring relays for unearthed supply systems
Operating controls
4
1
2
3
1 Test and reset button
2 Configuration and setting Front-face rotary switches for threshold value adjustment:
R.1 for R1 tens figures:
0, 10, 20, 30, 40, 50, 60, 70, 80, 90 kΩ in ten kΩ steps
R.2 for R1 units figures:
1, 2, 3, 4, 5, 6, 7, 8, 9, 10 kΩ in one kΩ steps
3 Indication of operational states U: green LED - control supply voltage
F: red LED - fault message
R: yellow LED - relay status
4 Marker label for devices without DIP switches
1 Front-face rotary switches to adjust the threshold value: R1.1 for R1 tens figure:
0, 10, 20, 30, 40, 50, 60, 70, 80, 90 kΩ in ten kΩ steps
R1.2 for R1 units figure:
1, 2, 3, 4, 5, 6, 7, 8, 9, 10 kΩ in one kΩ steps
R2.1 for R2 tens figure:
0, 20, 40, 60, 80, 100, 120, 140, 160, 180 kΩ in twenty kΩ steps
R2.2 for R2 units figure:
2, 4, 6, 8, 10, 12, 14, 16, 18, 20 kΩ in two kΩ steps
2 Test and reset button
3 Indication of operational states U: green LED – control supply voltage
F1: red LED – fault message
F2: yellow LED – relay status
4 DIP switches (see DIP switch functions)
1
2
3
4
2C
DC
25
3 0
21
F0
01
32
CD
C 2
53
01
5 F
00
13
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/64
2
Insulation monitoring relays for unearthed supply systems
Insulation monitoring in IT systems
L1
L2
L3
N
PE
M
A1 11 S2 S321 S1
L+ V12 14A2V1-V1+
22 24 L- K
Consumer3~
w
CM-IWN.x
In electricity supply systems, an earthing system defines the electrial potential of the conductors relative to that of the earth’s conductive surface. The choice of earthing system has implications for the safety and electromagnetic compatibility of the power supply. Note that regulations for earthing (grounding) systems vary considerably among different countries.
The international standard IEC 60364 distinguishes three families of earthing arrangements, using the two-letter codes TN, TT
and IT.
The first letter indicates the connection between earth and the power-supply equipment (generator or transformer):
T: direct connection of a point with earth (Latin: terra)
I: no point is connected with earth (insulation), except perhaps via a high impendance
The second letter indicates the connection between earth and the electrical device being supplied:
T: direct connection of a point with earth
N: direct connection to neutral at the origin of installation,
which is connected to the earth
IT supply systemsThe IT system is supplied either by an isolation transformer or a voltage source, such as battery or a generator.
In this system no active conductor is directly connected to earth potential. The advantage of this is that only a small fault cur-
rent can flow in case of an insulation fault. This current is essentially caused by the leakage capacitance of the system.
The fuse of the system or MCB does not respond, thus maintaining the voltage supply and therefore operation even in case of
a phase-to-earth fault.
The high reliability of an IT system is guaranteed thanks to continous insulation monitoring.
The insulation monitoring device recognizes insulation faults as they develop, and immediately reports that the value has fallen
below the minimum. This prevents operational interruptions caused by a second more severe insulation fault.
2/65 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Insulation monitoring relays for unearthed supply systems
Selection table
Ord
er n
um
ber
1S
VR
73
06
70
R0
20
0
1S
VR
74
06
70
R0
20
0
1S
VR
73
06
60
R0
10
0
1S
VR
74
06
60
R0
10
0
1S
VR
75
06
60
R0
20
0
1S
VR
76
06
60
R0
20
0
1S
VR
75
06
60
R0
30
0
1S
VR
76
06
60
R0
30
0
1S
VR
75
06
60
R0
40
0
1S
VR
76
06
60
R0
40
0
1S
VR
75
06
60
R0
50
0
1S
VR
76
06
60
R0
50
0
Typ
e
CM
-IW
S.2
S
CM
-IW
S.2
P
CM
-IW
S.1
S
CM
-IW
S.1
P
CM
-IW
N.1
S
CM
-IW
N.1
P
CM
-IW
N.4
S
CM
-IW
N.4
P
CM
-IW
N.5
S
CM
-IW
N.5
P
CM
-IW
N.6
S
CM
-IW
N.6
P
Rated control supply voltage Us
24 - 240 VAC/DC � � � � � � � � � � � �
Measuring voltages
250 V AC (L-PE) � �
400 V AC (L-PE) � � � � � � � � � �
690 V AC (L-PE) �1) �1) �1) �1) �1) �1) �1) �1)
300 V DC (L-PE) � �
600 V DC (L-PE) � � � � � � � �
1000 V DC (L-PE) �1) �1) �1) �1) �1) �1) �1) �1)
Measuring range
1 - 100 kΩ � � � � � � � � � � � �
2 - 200 kΩ � � � � � � � �
System leakage capacitance, max.
10 μF � � � �
20 μF � �
500 μF � �
1000 μF � �
2000 μF � �
Output
1 c/o � � � �
1 x 2 c/o or 2 x 1 c/o � � � � � � � �
Operating principle
Open-circuit principle � � � �
Open- or closed-circuit principle adjustable � � � � � � � �
Test
Front-face button or control input � � � � � � � � � � � �
Reset
Front-face button or control input � � � � � � � � � � � �
Fault storage / latching configurable � � � � � � � � � � � �
Non volatile storage configurable � � � � � � � � � � � �
Interrupted wire detection � � � � � � � �Threshold values configurable 1 1 1 1 2 2 2 2 2 2 2 2
Connection type
Push-in terminals � � � � � �Double-chamber cage connection terminals � � � � � �
1) With coupling unit CM-IVNscrew version CM-IVN.S: 1SVR750669R9400
push-in version CM-IVN.P: 1SVR760669R9400
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/66
2
Insulation monitoring relays for unearthed supply systems
Ordering details
Description
The high reliability of an IT system is guaranteed thanks to continuous insulation monitoring.
An insulation monitoring device recognizes insulation faults as they develop, and immediately
reports that the value has fallen below the minimum. This prevents operational interruption
caused by a second, more severe insulation fault.
ABB developed a totally new range of insulation monitors for AC, DC or mixed AC/DC IT Sys-
tems up to 690 V AC or 1000 V DC. With only 4 devices most standard applications can be
served. Additionally a version for solar applications with increased earth leakage capacitance
has been added.
Ordering detailsRated control supply voltage = measuring voltage
Nominal voltage Un of the distribution system to be monitored
System leakage capaci-tance, max.
Adjust-ment range of the specified response value Ran (threshold)
Type Order code Price
1 pce
Weight(1 pce)
kg (lb)
24-240 V AC/DC0-250 V AC / 0-300 V DC
10 μF 1-100 k
CM-IWS.1S 1SVR730660R0100 0.148 (0.326)
CM-IWS.1P 1SVR740660R0100 0.137 (0.302)
24-240 V AC/DC 0-400 V AC 10 μF 1-100 k
CM-IWS.2S 1SVR730670R0200 0.141 (0.311)
CM-IWS.2P 1SVR740670R0200 0.130 (0.287)
24-240 V AC/DC0-400 V AC / 0-600 V DC
20 μF
1-100 k 2-200 k (activated / de-activated by DIP-switch)
CM-IWN.1S 1SVR750660R0200 0.241 (0.531)
CM-IWN.1P 1SVR760660R0200 0.217 (0.478)
24-240 V AC/DC0-400 V AC / 0-600 V DC
500 μF
CM-IWN.4S 1SVR750660R0300 0.241 (0.531)
CM-IWN.4P 1SVR760660R0300 0.217 (0.478)
24-240 V AC/DC0-400 V AC / 0-600 V DC
1000 μF
CM-IWN.5S 1SVR750660R0400 0.241 (0.531)
CM-IWN.5P 1SVR760660R0400 0.217 (0.478)
24-240 V AC/DC0-400 V AC / 0-600 V DC
2000 μF
CM-IWN.6S 1SVR750660R0500 0.241 (0.531)
CM-IWN.6P 1SVR760660R0500 0.217 (0.478)
Ordering details - Coupling unitRated control supply voltage = measuring voltage
Nominal voltage Un of the distribu-tion system to be monitored
Type Order code Price
1 pce
Weight(1 pce)
kg (lb)
Passive device, no control supply voltage needed
0-690 V AC / 0-1000 V DC
CM-IVN.S 1SVR750669R9400 0.179 (0.395)
CM-IVN.P 1SVR760669R94000.165 (0.364)
2C
DC
25
1 0
17
V0
01
22
CD
C 2
51
00
9 V
00
12
2C
DC
25
1 0
20
V0
01
22
CD
C 2
52
02
7 V
00
12
CM-IWS.2
CM-IWS.1
CM-IWN.1
CM-IVNS: screw connection
P: push-in / easy connect
2/67 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Operational state LED U (green)
LED F (red)
LED R (yellow)
Start-up W OFF OFF
No fault V OFF 1)
Prewarning V W W
Insulation fault (below threshold value) V V 1)
KE/w wire interruption V U 1)
L+/L- wire interruption during system start-up / test function
W / X
T 1)
System leakage capacitance too high / invalid measurement result
V T 1)
Internal system fault 1) X 1)
Setting fault 2) W W W
Test function X OFF 1)
No fault after fault storage 3) V 4) X
Operational state LED U (green)
LED F (red)
LED R (yellow)
Start-up W OFF OFF
No fault V OFF V
Insulation fault (below threshold value) V V OFF
Invalid measuring result V T OFF
KE/w wire interruption (only CM-IWS.1) V U OFF
CM-IWS.1: System leakage capacitance too high / invalid measurement result
X X OFF
CM-IWS.2: Invalid measurement result
V T OFF
Internal system fault OFF X OFF
Test function X OFF OFF
No fault after fault storage 3) V 4) X
LEDs, status information and fault messages CM-IWN.x LEDs, status information and fault messages CM-IWS.x
Insulation monitoring relays for unearthed supply systems
Operating state indication, Connection diagrams, DIP switches
Connection diagram CM-IWS.2A1S1 S2 S3
11
w
LA2
w
A1
R < w
A2
L
14 12
12 14
11
2C
DC
25
2 1
02
F0
00
9
Connection diagram CM-IWS.1
Connection diagram CM-IWN.1, 4, 5, 6 Connection diagram CM-IVN
A1S1 S2 S3
KE11
w
L-L+A2
KEw
L-
A1
R < w
A2
L+
14 12
12 14
11
2C
DC
25
2 1
03
F0
00
9
VE Connection to CM-IWN.x - w
VS Connection to CM-IWN.x - VS
L+ Connection to CM-IWN.x - L+
V1+ Connection to CM-IWN.x - V1+
L- Connection to CM-IWN.x - L-
V1- Connection to CM-IWN.x - V1-
VL+
VL-
Measuring circuit / Measuring input
Connection to the system
Vw Measuring circuit / Measuring input
Connection to earth
A1-A2 Control supply voltage
S1-S3 Remote test
S2-S3 Remote reset
L+, L– Measuring circuit/input, system connection
w, KE Measuring circuit/input, earth connections
1-12/14 Output relay, closed-circuit principle
A1-A2 Control supply voltage
S1-S3 Remote test
S2-S3 Remote reset
L Measuring circuit/input, system connection
w Measuring circuit/input, earth connections
11-12/14 Output relay, closed-circuit principle
A1-A2 Control supply voltage
S1-S3 Remote test
S2-S3 Remote reset
L+, L– Measuring circuit/input, system connection
w, KE Measuring circuit/input, earth connections
VS, V1+, V1 Connections for the coupling unit (if used)
11-12/14 Output relay 1, open- or closed-circuit principle
21-22/24 Output relay 2, open- or closed-circuit principle
2C
DC
25
2 1
04
F0
00
9
2C
DC
25
2 0
10
F0
01
3
A1 11 S2 S321 S1
w
L+ VS12 14A2V1-V1+
KEw
L-
A1
R < w
A2
L+
22 24 L- KE
12 14
11
22 24
21
VL+ VL-
VL- VL+
Vw
L-L+
L+
VEV1-
L- V1-
V1+
V1+
VS
ON OFF (default)
DIP switch 1 Operating
principle of the
output relays
Closed-circuit principle g
If closed-circuit principle is selected, the output relays de-
energize in case a fault is occuring. In non-fault state the
relays are energized.
Open-circuit principle h
If open-circuit principle is selected, the output relays
energize in case a fault is occuring. In non-fault state the
relays are de-energized.
DIP switch 2 Non-volatile fault
storage
Fault storage activated (latching) f
If the fault storage function is activated, the output relays
remain in tripped position until a reset is done either by the
front-face button or by the remote reset connection S2-S3.
This function is non-volatile.
Fault storage de-activated (non latching) e
If the fault storage function is de-activated, the output
relays switch back to their original position as soon as the
insulation fault no longer exists.
DIP switch 3 Interrupted wire
detection
Interrupted wire detection activated u
With this configuration, the CM-IWN.1 monitoring relays
the wires connected to w and KE for interruptions.
Interrupted wire detection de-activated v With this
configuration the interrupted wire detection is de-
activated.
DIP switch 42 x 1 c/o, 1 x 2 c/o
2 x 1 c/o (SPDT) contact i
If operating principle 2 x 1 c/o contact is selected, the
output relay R1 (11-12/14) reacts to threshold value R1
(final switch-off) and the output relay R2 (21-22/24) reacts
to threshold value R2 (prewarning)
1 x 2 c/o (SPDT) contacts j
If operating principle 1 x 2 c/o contacts is selected, both
output relays R1 (11-12/14) and R2 (21-22/24) react
synchronously to threshold value R1. Settings of the
threshold value R2 have no effect on the operation.
2C
DC
25
2 0
50
F0
b0
9
Position 4 123
ON
OFF
i u f g
he
v
j
DIP switches of CM-IWN.1, 4, 5, 6
1) Depending on the configuration.2) Possible faulty setting: The threshold value for final switch-off is set at a higher value than the threshold value for prewarning3) The device has triggered after an insulation fault. The fault has been stored and the insulation resistance has returned to a higher value than the threshold value plus hysteresis.4) Depending on the fault
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/68
2
Insulation monitoring relays for unearthed supply systems
Technical data
*in combination with CM-IVN ±1.5 k�
Data at Ta = 25 °C and rated values, unless otherwise indicated
CM-IWS.2 CM-IWS.1 CM-IWN.1, 4, 5, 6
Input circuit - Supply circuit A1 - A2Rated control supply voltage U
s24-240 V AC/DC
Rated control supply voltage tolerance -15...+10 %
Typical current / power consumption 24 V DC 30 mA / 0.7 VA 35 mA / 0.9 VA 55 mA / 1.3 VA
115 V AC 12 mA / 1.4 VA 17 mA / 2.0 VA 20 mA / 2.3 VA
230 V AC 12 mA / 2.8 VA 14 mA / 3.2 VA 15 mA / 3.5 VA
Rated frequency fs
DC or 15-400 Hz
Frequency range AC 13.5-440 Hz
Power failure buffering time min. 20 ms
Input circuit - Measuring circuit L, w L+, L-, w, KE L+, L-, w, KEMonitoring function insulation resistance monitoring of IT systems (IEC/EN 61557-8)
Measuring principle superimposed DC voltage
prognostic measuring principle with superimposed square wave signal
Nominal voltage Un of the distribution system to be monitored 0-400 V AC 0-250 V AC /
0-300 V DC0-400 V AC / 0-600 V DC
Voltage range of the distribution system to be monitored 0-460 V AC (tolerance +15 %)
0-287.5 V AC / 0-345 V DC (tolerance +15 %)
0-460 V AC / 0-690 V DC (tolerance +15 %)
Rated frequency fN of the distribution system to be monitored 50-60 Hz DC or 15-400 Hz DC or 15-400 Hz
System leakage capacitance Ce
max. 10 μF CM-IWN.1: 20 μFCM-IWN.4: 500 μFCM-IWN.5 1000 μFCM-IWN.6: 2000 μF
Tolerance of the rated frequency fN
45-65 Hz 13.5-440 Hz 13.5-440 Hz
Extraneous DC voltage Ufg (when connected to an AC system) max. none 290 V DC 460 V DC
Number of possible response / threshold values 1 2
Adjustment range of the specified response value Ran
(threshold)min.-max. 1-100 � –
min.-max. R1 – 1-100 k�min.-max. R2 – 2-200 k� (activated /
de-activated by DIP-switch)
Adjustment resolution 1 k�R1 1 k� 1 k�R2 – 2 k�
Tolerance of the adjusted threshold value / Relative percentage uncertainty A at -5...+45 °C, U
n = 0-115 %, U
s = 85-110 %, f
N, f
s, C
e = 1μF
at 1-10 k RF
±0.5 k� –
at 10-100 k RF
±6 % –
at 1-15 k RF
– ±1 k�*
at 15-200 k RF
– ±8 %
Hysteresis related to the threshold value 25 %; min. 2 k�Internal impedance Z
iat 50 Hz 135 k� 100 k� 155 k�
Internal DC resistance Ri
185 k� 115 k� 185 k�
Measuring voltage Um
15 V 22 V 24 V
Tolerance of measuring voltage Um
+10 %
Measuring current Im
max. 0.1 mA 0.3 mA 0.15 mA
Response time tan
pure AC system 0.5 x Ran
and Ce = 1 μF max. 10 s
DC system or AC system with connected rectifiers – max. 15 s
Repeat accuracy (constant parameters) < 0.1 % of full scale
Accuracy of Ra (measured value) within the rated control supply voltage tolerance < 0.05 % of full scale
Accuracy of Ra (measured value) within the
operation temperature rangeat 1-10 k� R
F 5 / K
at 10-100 k� RF
0.05 % / K –
at 10-200 k� RF
– 0.05 % / K
Transient overvoltage protection (w - terminal) Z-diode avalanche diode
Input circuit - Control circuits S1 - S2 - S3Control inputs - volt free S1-S3 remote test
S2-S3 remote reset
Maximum switching current in the control circuit 1 mA
Maximum cable length to the control inputs 50 m - 100 pF/m [164 ft - 30.5 pF/ft]
Minimum control pulse length 150 ms
No-load voltage at the control input ≤ 24 V ± 5 % ≤ 24 V DC
Indication of operational statesControl supply voltage LED U (green)
Fault message LED F (red)
Relay status LED R (yellow)
2/69 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Insulation monitoring relays for unearthed supply systems
Technical data
CM-IWS.2 CM-IWS.1 CM-IWN.1, 4, 5, 6
Output circuitsKind of output relay, 1 c/o (SPDT) contact 2 x 1 or 1 x 2 c/o
(SPDT) contactsconfigurable
Operating principle closed-circuit principle 1) open- or closedcircuit principle 1)
configurable
Contact material AgNi alloy, Cd free
Rated voltage (VDE 0110, IEC 60947-1) 250 V AC / 300 V DC
Min. switching voltage / Min. switching current 24 V / 10 mA
Max. switching voltage / Max. switching current see data sheet
Rated operational current Ie (IEC/EN 60947-
5-1)AC-12 (resistive) at 230 V 4 A
AC-15 (inductive) at 230 V 3 A
DC-12 (resistive) at 24 V 4 A
DC-13 (inductive) at 24 V 2 A
AC rating (UL 508) Utilization category (Control Circuit Rating Code)
B 300, pilot duty general purpose (250 V, 4 A, cos 0.75)
max. rated operational voltage 250 V AC
max. continuous thermal current at B 300
4 A
max. making/breaking apparent power at B 300
3600/360 VA
Mechanical lifetime 30 x 106 switching cycles
Electrical lifetime (AC-12, 230 V, 4 A) 0.1 x 106 switching cycles
Max. fuse rating to achieve short-circuit protection n/c contact 6 A fast-acting
n/o contact 10 A fast-acting
Conventional thermal current Ith (IEC/EN 60947-1) 4 A
General dataDuty time 100 %
Dimensions (W x H x D)
product dimension 22.5 x 85.6 x 103.7 mm (0.89 x 3.37 x 4.08 in)
45 x 85.6 x 103.7 mm (0.89 x 3.37 x 4.08 in)
packaging dimenesion 97 x 109 x 30 mm (3.82 x 4.29 x 1.18 in) 97 x 109 x 30 mm (3.82 x 4.29 x 1.18 in)
Weight net weight CM-IWS.2P: 0.130 kg (0.287 lb) CM-IWS.2S: 0.141 kg (0.311 lb)
CM-IWS.1P: 0.137 kg (0.302 lb)CM-IWS.1S: 0.148 kg (0.326 lb)
CM-IWN.xP: 0.217 kg (0.478 lb)CM-IWN.xS: 0.241 kg (0.531 lb)
gross weight CM-IWS.2P: 0.155 kg (0.342 lb) CM-IWS.2S: 0.166 kg (0.366 lb)
CM-IWS.1P: 0.162 kg (0.357 lb)CM-IWS.1S: 0.173 kg (0.381 lb)
CM-IWN.xP: 0.246 kg (0.542 lb)CM-IWN.xS: 0.270 kg (0.595 lb)
Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool
Mounting position any
Minimum distance to other units vertical not necessary
horizontal 10 mm (0.39 in)at U
n > 240 V
not necessary 10 mm (0.39 in)at U
n > 400 V
Material of housing UL 94 V-0
Degree of protection housing / terminal IP50 / IP20
Electrical connectionScrew connection technology Easy Connect Technology
(Push-in)
Wire size fine-strand with(out) wire end ferrule
1 x 0.5-2.5 mm2 (1 x 20-14 AWG)2 x 0.5-1.5 mm2 (2 x 20-16 AWG)
2 x 0.5-1.5 mm2 (2 x 20-16 AWG)
rigid 1 x 0.5-4 mm2 (1 x 20-12 AWG)2 x 0.5-2.5 mm2 (2 x 20-14 AWG)
2 x 0.5-1.5 mm2 (2 x 20-16 AWG)
Stripping length 8 mm (0.32 in)
Tightening torque 0.6-0.8 Nm (5.31-7.08 lb.in)
Environmental dataAmbient temperature ranges operation / storage / transport -25...+60 °C/-40...+85 °C/-40...+85 °C
Climatic category IEC/EN 60721-3-3 3K5 (no condensation, no ice formation)
Damp heat, cyclic IEC/EN 60068-2-30 6 x 24 h cycle, 55 °C, 95 % RH
Vibration, sinusoidal IEC/EN 60255-21-1 Class 2
Shock, half-sine IEC/EN 60255-21-2 Class 2
1) Closed-circuit principle: Output relay(s) de-energize(s) if a fault is occuring
Open-circuit principle: Output relay(s) energize(s) if a fault is occuring
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/70
2
Insulation monitoring relays for unearthed supply systems
Technical data
CM-IWS.2 CM-IWS.1 CM-IWN.1, 4, 5, 6
Isolation dataRated impulse withstand voltage U
imp between
all isolated circuits (IEC/EN 60947-1, IEC/EN 60664-1, VDE 0110-1)
supply / measuring circuit 6 kV
supply / output circuit 6 kV
measuring / output circuit 6 kV
output 1 / output circuit 2 4 kV
Pollution degree (IEC/EN 60664-1, VDE 0110-1) 3
Overvoltage category (IEC/EN 60664-1, VDE 0110-1) III
Rated insulation voltage Ui
(IEC/EN 60947-1, IEC/EN 60664-1, VDE 0110-1)supply / measuring circuit 400 V 300 V 600 V
supply / output circuit 300 V
supply / measuring circuit 400 V 300 V 600 V
output 1 / output circuit 2 - - 300 V
Basis isolation for rated control supply voltage (IEC/EN 60664-1, VDE 0110-1)
supply / measuring circuit 400 V AC / 300 V DC 250 V AC / 300 V DC 400 V AC / 600 V DC
supply / output circuit 250 V AC / 300 V DC
measuring / output circuit 400 V AC / 300 V DC 250 V AC / 300 V DC 400 V AC / 600 V DC
output 1 / output 2 250 V AC / 300 V DC
Protective separation (IEC/EN 61140) supply / output circuit 250 V AC / 250 V DC
supply / measuring circuit 250 V AC / 250 V DC
measuring / output circuit 250 V AC / 250 V DC
Test voltage between all isolated circuits, routine test (IEC/EN 60255-5, IEC/EN 61010-1)
supply / output circuit 2.32 kV, 50 Hz, 2 s
supply / measuring circuit 2.32 kV, 50 Hz, 2 s
measuring / output circuit 2.2 kV, 50 Hz, 1 s 2.53 kV, 50 Hz, 1 s
StandardsProduct standard IEC/EN 61557-1, IEC/EN 61557-8, IEC/EN 60255-1, EN 50178
Other standards EN 50178
Low Voltage Directive 2006/95/EC
EMC Directive 2004/108/EC
RoHS Directive 2011/65/EC
Electromagnetic compabilityInterference immunity to IEC/EN 61000-6-1, IEC/EN 61000-6-2, IEC/EN 61326-2-4
electrostatic discharge IEC/EN 61000-4-2 Level 3, 6 kV / 8 kV
radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 Level 3, 10 V/m (1 GHz) / 3 V/m (2 GHz) / 1 V/m (2.7 GHz)
electrical fast transient/burst IEC/EN 61000-4-4 Level 3, 2 kV / 5 kHz
surge IEC/EN 61000-4-5 Level 3, installation class 3, supply circuit and measuring circuit 1 kV L-L, 2 kV L-earth
conducted disturbances, induced by radio-frequency fields
IEC/EN 61000-4-6 Level 3, 10 V
voltage dips, short interruptions and voltage variations
IEC/EN 61000-4-11 Class 3
harmonics and interharmonics IEC/EN 61000-4-13 Class 3
Interference emissions IEC/EN 61000-6-3, IEC/EN 61000-6-4
high-frequency radiated IEC/CISPR 22, EN 55022 Class B
high-frequency conducted IEC/CISPR 22, EN 55022 Class B
2/71 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Insulation monitoring relays for unearthed supply systems
Technical data CM-IVN
Input circuit - Measuring circuit VL+, VL-, VwFunction expansion of the nominal voltage range of the insulation monitoring relay
CM-IWN to 690 V AC or 1000 V DC, max. length of connection cable 40 cmMeasuring principle see CM-IWN
Nominal voltage Un of the distribution system to be monitored 0-690 V AC / 0-1000 V DC
Voltage range of the distribution system to be monitored 0-793.5 V AC / 0-1150 V DC (tolerance +15 %)
Rated frequency fN of the distribution system to be monitored DC or 15-400 Hz
Tolerance of the rated frequency fN
13.5-440 Hz
System leakage capacitance Ce
max. identical to that of the insulation monitoring relay used
Extraneous DC voltage Ufg (when
connected to an AC system)max. 793.5 V DC
Tolerance of the adjusted threshold value / Relative percentage uncertainty A at -5...+ 45 °C, U
n = 0-115 %, U
s = 85-110 %, f
N, f
s, C
e = 1 μF
at 1-15 kΩ RF
±1.5 kΩ
at 15-200 kΩ RF
±8 %
Internal impedance Zi
at 50 Hz 195 kΩ
Internal DC resistance Ri
200 kΩ
Measuring voltage Um
24 V
Tolerance of measuring voltage Um +10 %
Measuring current Im
0.15 mA
General dataMTBF on request
Duty time 100 %
Dimensions (W x H x D) 45 x 78 x 100 mm (1.78 x 3.07 x 3.94 in)
Weight gross weight 0.200 kg (0.441 lb)
net weight 0.169 kg (0.373 lb)
Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool
Mounting position any
Minimum distance to other units vertical not necessary
horizontal 10 mm (0.39 in) at Un > 600 V
Degree of protection IP50 / IP20
Electrical connectionWire size fine-strand with(out) wire
end ferrule2 x 0.75-2.5 mm² (2 x 18-14 AWG)
rigid 2 x 0.5-4 mm² (2 x 20-12 AWG)
Stripping length 7 mm (0.28 in)
Tightening torque 0.6-0.8 Nm (5.31-7.08 lb.in)
Max. length of connection cable to CM-IWN 40 cm
Environmental dataAmbient temperature ranges operation / storage / transport -25...+60 °C / -40...+85 °C / -40...+85 °CClimatic category IEC/EN 60721-3-3 3K5 (no condensation, no ice formation)Damp heat, cyclic IEC/EN 60068-2-30 6 x 24 h cycle, 55 °C, 95 % RHVibration, sinusoidal IEC/EN 60255-21-1 Class 2Shock, half-sine IEC/EN 60255-21-2 Class 2
Isolation dataRated impulse withstand voltage U
imp between all
isolated circuits (IEC/EN 60947-1, IEC/EN 60664-1,VDE 0110-1)
input circuit / PE 8 kV
Pollution degree (IEC/EN 60664-1, VDE 0110-1) 3
Overvoltage category (IEC/EN 60664-1, VDE 0110-1) III
Rated insulation voltage Ui
(IEC/EN 60947-1, IEC/EN 60664-1,VDE 0110-1)input circuit / PE 1000 V
Test voltage between all isolated circuits, routine test (IEC/EN 60255-5, IEC/EN 61010-1)
input circuit / PE 3.3 kV, 50 Hz, 1 s
StandardsProduct standard IEC/EN 61557-1, IEC/EN 61557-8, IEC/EN 60255-1, EN 50178
Other standards EN 50178
Low Voltage Directive 2006/95/EC
EMC Directive 2004/108/EC
RoHS Directive 2011/65/EC
Electromagnetic compabilityInterference immunity to IEC/EN 61000-6-1, IEC/EN 61000-6-2, IEC/EN 61326-2-4
electrostatic discharge IEC/EN 61000-4-2 Level 3, 6 kV / 8 kV
radiated, radio-frequency, electromagnetic field
IEC/EN 61000-4-3 Level 3, 10 V/m (1 GHz) / 3 V/m (2 GHz) / 1 V/m (2.7 GHz)
electrical fast transient/burst IEC/EN 61000-4-4 Level 3, 2 kV / 5 kHzsurge IEC/EN 61000-4-5 Level 3, installation class 3, supply circuit
and measuring circuit 1 kV L-L, 2 kV L-earthconducted disturbances, induced by radio-frequency fields
IEC/EN 61000-4-6 Level 3, 10 V
voltage dips, short interruptions and voltage variations
IEC/EN 61000-4-11 Level 3
harmonics and interharmonics IEC/EN 61000-4-13 Level 3Interference emission IEC/EN 61000-6-3, IEC/EN 61000-6-4
high-frequency radiated IEC/CISPR 22, EN 50022 Class Bhigh-frequency conducted IEC/CISPR 22, EN 50022 Class B
2
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/72
Insulation monitoring relays for unearthed supply systems
Notes
2/73 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Motor load monitoring relays
Product picture
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/74
2
Motor load monitoring relays
Table of contents
Motor load monitoring relays
Fields of application 2/75
Ordering details 2/76
Technical information 2/77
Technical data 2/78
2/75 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Motor load monitoring relays
Fields of application
NL3L2L1
K1
U V W
M 3~
50-60 Hz
NL1
K1
U1 U2
M 1~
50-60 Hz
NL3L2L1
K1
U V W
M 3~
~~
50-60 Hz 110-500 V, 15-400 Hz
NL3L2L1
K1
U V W
M 3~
l
k
L
K
50-60 Hz
NL1
K1
U1 U2
M 1~
l
k
L
K
50-60 Hz
L3L2L1
K1
U V W
M 3~
DC AC
110-240 V 15-400 Hz
The motor load monitor relay monitors the load states of
single-phase and three-phase asynchronous motors.
The evaluation of the phase angle between current and volt-
age allows a very precise monitoring of the load states.
Compared with other conventional measuring principles
Main applications – Pump monitoring
– Dry-running protection (underload)
– Closed valves (overload)
– Pipe break (overload)
– Heating, air-conditioning, ventilation
– Monitoring of filter pollution
– V-belt breakage (underload)
– Closed shutters/valves (overload)
– Air ventilating volume
– Agitating machines
– High consistency within the tank (overload)
– Pollution of the tank (overload)
– Transport/Conveyance
– Congested conveyor belts (overload)
– Jamming of belts (overload)
– Material accumulation in spiral conveyors (overload)
– Lifting platforms
– Machine installation
– Wear of tools, e.g. worn saw blades in circular saws,
etc. (overload)
– Tool breakage (underload)
– V-belt drives (breakage underload)
(e.g. pressure transducers, current measurement), cos
monitoring is a more precise and economical alternative.
The motor is used as a sensor for its own load status.
Wiring examples (for motor currents � 20 A)
Filter pollutionV-belt monitoring
Dry-running protection
Pump control
Ventilator monitoring
Filter pollution
Wiring examples (for motor currents � 20 A)
1S
VC
11
0 0
00
F 0
13
1
1S
VC
11
0 0
00
F 0
13
2
1S
VC
11
0 0
00
F 0
13
3
1S
VC
11
0 0
00
F 0
13
11
SV
C 1
10
00
0 F
01
32
1S
VC
11
0 0
00
F 0
13
3
1S
VC
11
0 0
00
F 0
47
0
1S
VC
11
0 0
00
F 0
47
31
SV
C 1
10
00
0 F
04
71
1S
VC
11
0 0
00
F 0
47
2
Detected fault - installation is
switched off
Starting time delay
Detected fault - installation is
switched off
Starting time delay
Starting time delay Detected fault - installation is
switched off
Starting time delay Detected fault - installation is
switched off
Response delay Response delay
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/76
2
Motor load monitoring relays
Ordering details
Description
The motor load monitor CM-LWN monitors the load of single-phase and three-phase asyn-
chronous motors. The evaluation of the phase angle between current and voltage (cos
monitoring) allows a very precise monitoring of the load status.
Ordering detailsRated control supply voltage = measuring voltage
Current range Type Order code Price
1 pce
Weight(1 pce)
kg (lb)
24-240 V AC/DC
0.5-5 A
CM-LWN
1SVR450335R0000 0.30 (0.66)
110-130 V AC 1SVR450330R0000 0.30 (0.66)
220-240 V AC 1SVR450331R0000 0.30 (0.66)
380-440 V AC 1SVR450332R0000 0.30 (0.66)
480-500 V AC 1SVR450334R0000 0.30 (0.66)
24-240 V AC/DC
2-20 A
1SVR450335R0100 0.30 (0.66)
110-130 V AC 1SVR450330R0100 0.30 (0.66)
220-240 V AC 1SVR450331R0100 0.30 (0.66)
380-440 V AC 1SVR450332R0100 0.30 (0.66)
480-500 V AC 1SVR450334R0100 0.30 (0.66)
Current transformers „Ordering details - CM-CT current transformers“ on page 131”
1S
VR
45
0 3
35
F0
10
0
CM-LWN
Characteristics – Pump monitoring
– Under- and overload monitoring cos in one unit
– Adjustable starting delay 0.3-30 s
– Direct measurement of currents up to 20 A
– Adjustable response time delay 0.2-2 s
– Single-phase or three-phase monitoring
– 2 x 1 c/o contact, closed-circuit principle
– 3 LEDs for status indication
4
12
3
5
7
1 Starting delay „Time S“
2 Response delay „Time R“
3 Threshold for load limit cos max
4 Threshold for load limit cos min
5 Reset button
6 Indication of operational states U: green LED – control supply voltage
cos max
: red LED – cos max
exceeded
cos min
: red LED – below cos min
7 Marker label
2C
DC
25
3 0
10
F0
01
3
2/77 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Motor load monitoring relays
Technical information
The CM-LWN module monitors the load status of inductive loads.
The primary application is the monitoring of single- or three-phase asynchronous motors (squirrel cage) under varying load
conditions. The measuring principle is based on the evaluation of the phase shift ( ) between the voltage and the current in one
phase.
The phase difference is nearly inversely proportional to the load. Therefore, cos , measured relatively from 0 to 1, measures
the relationship of effective power to apparent power. A value towards 0 indicates low load and a value towards 1 indicates
high load.
Threshold values can be set individually for cos max
and cos min
If the set threshold value is reached, a LED lights up and the
relay is de-energized.
If cos returns to the acceptable limits (taking into account the hysteresis), the relay is reset to its original state and the LED
flashes permanently to indicate the occurrence of the trip event. This message can be deleted using the reset button or by
switching off the supply.
A time delay (Time S) of 0.3 to 30 s can be set for the starting phase of the motor. It is also possible to set a response delay
time (Time R) of 0.2 to 2 s to suppress unwanted tripping due to unavoidable short load changes during normal operation.
To guarantee correct operation of the response delay (Time R), the adjusted value for cos max
has to be higher than the value
for cos min
plus the hysteresis. Consequently, the overload and underload indication must not be active at the same time.
Due to the internal electrical isolation of the supply circuit and the measuring circuit, it is also possible to use the device in sys-
tems with different supply voltages.
TS TSTR TR TR
Function diagram - CM-LWN
A1-A2 Rated control supply voltage
L1/K-L1/L Measuring current
L1/K-L2-L3 Measuring voltage
15-16/18 Output contacts - underload (cos min
)
25-26/28 Output contacts - overload (cos max
)
closed-circuit principle
Connection diagram CM-LWN
1S
VC
11
0 0
00
F0
13
0
2C
DC
25
2 1
05
F0
00
4
A1-A2
Current in L1
con max
hysteresis
con min
15-18
15-16
25-28
25-26
Reset button
Red LED - cos min
Red LED - cos max
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/78
2
Motor load monitoring relays
Technical data
Type CM-LWNInput circuit - Supply circuit A1-A2Rated control supply voltage U
s - power
consumptionA1-A2 24-240 V AC/DC approx. 8.4 VA/WA1-A2 110-130 V AC approx. 3.6 VAA1-A2 220-240 V AC approx. 3.6 VAA1-A2 380-440 V AC approx. 3.6 VAA1-A2 480-500 V AC approx. 3.6 VA
Rated control supply voltage Us tolerance -15 %...+10 %
Rated frequency AC versions 50-60 HzAC/DC versions 15-400 Hz or DC
Duty time 100 %
Measuring circuit L1/L-L1/K-L2-L3Monitoring function Motor load monitoring by cos
Voltage range L1/K-L2-L3 110-500 V AC single-phase or three-phaseCurrent range L1/L-L1/K 0.5-5 A version 2-20 A versionPermissible overload of current input 25 A for 3 s 100 A for 3 sThresholds cos
min and cos
max adjustable from 0 to 1
Hysteresis (related to phase angle in °) 4°
Frequency of measuring voltage 15-400 HzResponse time 300 ms
Timing circuits indication of over- and undervoltage faultStart-up time (Time S) 0.3-30 s, adjustableResponse delay (Time R) 0.2-2 s, adjustableAccuracy within the rated control supply voltage tolerance �t � 0.5 %Accuracy within the temperature range �t � 0.06 % / °C
Indication of operational statesControl supply voltage U: green LEDbelow cos
mincos
min: red LED
cos max
exceeded cos max
: red LED
Output circuits 15-16/18, 25-26/28Kind of output 2 x 1 c/o contactOperational principle closed-circuit principle 1)
Contact material AgCdORated voltage (VDE 0110, IEC 664-1, IEC 947-1) 250 VMax. switching voltage 400 V AC, 300 V DCRated operational current I
e (IEC/EN 60947-1) AC-12 (resistive) 230 V 4 A
AC-15 (inductive) 230 V 3 ADC-12 (resistive) 24 V 4 A
DC-13 (inductive) 24 V 2 AAC rating (UL 508) Utilization category (Control Circuit Rating Code) B 300
max. rated operational voltage 300 V ACmax. continuous thermal current at B 300 5 A
max. making/breaking apparent power at B 300 3600/360 VAMechanical lifetime 30 x 106 switching cyclesElectrical lifetime at AC-12, 230 V, 4 A 0.1 x 106 switching cyclesMax. fuse rating to achieve short-circuit protection
n/c / n/o contact 10 A fast-acting / 10 A fast-acting
General dataDimensions (W x H x D) 45 mm x 78 mm x 100 mm (1.77 inch x 3.07 inch x 3.94 inch)Mounting position any
Degree of protection housing / terminals IP50 / IP20Ambient temperature range operation / storage -25...+65 °C / -40...+85 °CMounting DIN rail (IEC/EN 60715)
Electrical connectionWire size fine-strand with wire end ferrule 2 x 2.5 mm2 (2 x 14 AWG)
StandardsProduct standard IEC 255-6, EN 60255-6Low Voltage Directive 2006/95/ECEMC Directive 2004/108/EC, 91/263/EEC, 92/31/EEC, 93/68/EEC, 93/67/EEC
Electromagnetic compatibility EN 61000-6-2, EN 61000-6-4electrostatic discharge IEC/EN 61000-4-2 Level 3 (6 kV / 8 kV)radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 Level 3 (10 V/m)electrical fast transient / burst IEC/EN 61000-4-4 Level 3 (2 kV / 5 kHz)surge IEC/EN 61000-4-5 Level 4 (2 kV L-L)conducted disturbances, induced by radio-frequency fields IEC/EN 61000-4-6 Level 3 (10 V)
Operational reliability (IEC 68-2-6) 5 gMechanical resistance (IEC 68-2-6) 10 gEnvironmental testing (IEC 68-2-30) 24 h cycle time, 55 °C, 93 % rel., 96 h
Isolation dataRating (HD 625.1 S1, VDE 0110, IEC 664-1, IEC 60255-5)Rated insulation voltage between supply- , measuring- and output circuit 250 V, 400 V, 500 V depending on the versionRated impulse withstand voltage between all isolated circuits 4 kV / 1.2 - 50 μsTest voltage between all isolated circuits 2,5 kV, 50 Hz, 1 min.Pollution category 3Overvoltage category III
1) Open-circuit principle: Output relay is energized if the measured value exceeds/drops below the adjusted threshold.
Closed-circuit principle: Output relay is de-energized if the measured value exceeds/drops below the adjusted threshold.
2/79 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Motor control and protection
Product group picture
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/80
2
Motor control and protection
Table of contents
Motor control and protection
Benefits and advantages 2/81
Technical data 2/82
2/81 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Motor control and protection
Benefits and advantages
Motor protection – Overload, underload
– Overvoltage, undervoltage
– Blocked rotor, low / high current
– Phase failure, imbalance, phase sequence
– Earth leakage
– Thermistor protection
– Limitation of starts per time
– One single version with integrated measuring system cov-
ers the rated motor current from 0.24 to 63 A
Motor control – Integrated and easy to parametrize motor starter functions
like direct, reverse, star-delta,...
– Additionally free programmable logic for application spe-
cific control functions
– Expansion modules DX111, DX122 for more I/Os
– Expansion modules VI150, VI155 for 3-phase voltage
measuring
– Analog and temperature module AI111
Motor diagnostics – Quick and comprehensive access to all relevant data via
fieldbus and/or operator panel
– Current, thermal load
– Phase voltages
– Power factor
– Energy
Communication – Communication-independent basic device
– Freely selectable fieldbus protocol with FieldBusPlug
– Profibus DP
– DeviceNet
– Modbus RTU
– Ethernet Modbus TCP
– Profinet
Typical application segments – Oil & gas
– Cement
– Paper
– Mining
– Steel
– Chemical industry
UMC100.3 is a flexible, modular and expandable motor management system for constant-speed low-voltage range motors.
It's most important tasks include motor protection, prevention of plant standstills and the reduction of down time. This is made
possible by early information relating to possible motor problems which avoids unplanned plant standstills. Even if a motor
trips, quick diagnosis of the cause of the fault serves to reduce downtime.
UMC100.3 combines in a very compact unit:
Further information
UMC Catalog 2CDC 190 022 C0206
UMC Brochure 2CDC 135 011 B0203
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/82
2
Motor control and protection
Technical data
Basic device UMC100.3Main power
Voltage max 1000 V AC
Frequency 45…65 Hz
Rated motor current 0.24…63 A, without accessoriesHigher currents with external transformer
Tripping classes 5E, 10E, 20E, 30E, 40E in accordance with EN/IEC 60947-4-1
Short-circuit protection Separate fuse on network side
Control unit
Supply voltage 24 V DC, 110-240 V AC/DC
Inputs 6 digital inputs 24 V DC1 PTC input
Outputs 3 digital relay outputs1 digital transistor output
Expansion modulesThe UMC100.3 can be expanded with maximum 4 expanstion modules: One digital expansion module DX111 or DX122, one module VI150 or VI155 and 2 analog modules AI111. Communication takes place via a simple two-wire line. The maximum distance allowed between the UMC100.3 and the expansion module is 3 m.
Digital expansion modules DX111 / DX122Expands the UMC100.3 to include additional digital inputs and outputs and an analog output
Supply voltage 24 V DC
Inputs DX111: 8 digital inputs 24 V DC DX122 8 digital inputs 110/230 V AC
Outputs 4 digital relay outputs 1 analog output, 0/4…20 mA, / 0…10 V configurable
Voltage modules VI150/VI155Voltage modules for determining phase voltages, power factor (cos j), active power, apparent power, energy, harmonic content (THD)
VI150 for use in grounded networksVI155 for use in grounded and ungrounded networks
Supply voltage 24 V DC
Voltage inputs L1, L2, L3
Rated voltage range 150 … 690 V AC
Outputs 1 digital relay output
Analog module AI111Expand the UMC100.3 with analog and temperature inputs
Supply voltage 24 V DC
Inputs 0-10 V, 0/4-20 mA PT100, PT1000, 2- or 3-wire connectionKTY83, KTY84, NTC
2/83 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Motor control and protection
Technical data
Ethernet communication interfacesMounted in the MCC cable chamber; connection of 1 to 4 motor controllers UMC100.3 via simple cables
MTQ22 for Modbus TCP
PNQ22 for Profinet IO
UMC100-PAN control panelInstallation on the device or on the switching cabinet doorGraphics-enabled and backlit display, 3 LEDs for status indicationFreely configurable error messagesUSB port for PC connectionMultilingual: German, English, French, Italian, Polish, Portuguese, Spanish, Russian
Fieldbus communication interfacesCan be mounted direct on the UMC100.3 or separate in the cable chamber of the MCC. Connection for standard fieldbus cables with 9-pole Sub-D (Profibus DP) or terminal blocks
PDP32 for Profibus DP
DNP31 for DeviceNet
MRP31 for Modbus RTU
CEM11 earth leakage sensorsSummation current transformer for connecting to a digital inputMounting with bracket on DIN busbar or wallModels
CEM11-FBP.20 80 – 1.700 mA 20 mm Ø
CEM11-FBP.35 100 – 3.400 mA 35 mm Ø
CEM11-FBP.60 120 – 6.800 mA 60 mm Ø
CEM11-FBP.120 300 – 13.600 mA 120 mm Ø
Current transformer CT4L / CT5LOnly required for rated motor currents >63 ALinear transformer, 3-phase with terminal block, designed for connecting leads Cu 2.5 mm2
2
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/84
Motor control and protection
Notes
2/85 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Thermistor motor protection relays
Product group picture
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/86
2
Thermistor motor protection relays
Table of contents
Thermistor motor protection relays
Benefits and advantages, Applications 2/87
Operating controls 2/88
Selection table CM-MSS range 2/89
Ordering details 2/90
Ordering details - PTC temperature sensors C011 2/91
Technical data 2/92
Connection diagrams 2/95
Circuit diagram 2/96
2/87 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Thermistor motor protection relays
Benefits and advantages, Applications
Direct temperature measuringGenerally, motor damages caused by overload or overheating
situations can be prevented in different ways. Compared to
the indirect temperature measuring which monitors the motor
current, the temperature inside the motor can be measured by
direct temperature measuring.
This enables direct control and evaluation of the following
operating conditions like:
– Heavy duty starting
– Increased switching frequency
– Single phase operation
– Phase unbalance
– High ambient temperature
– Insufficient cooling
– Breaking operation
Therefore the consequences from overheating like abrasion as
well as electrical failures can be prevented.
The direct measuring principle is carried out by a combination
of the thermistor motor protection relay and 3 PTC sensors
which are installed directly in the motor by the manufac-
turer. Those 3 PTC sensors are placed directly at the thermal
hotspots, the motor windings.
The thermistor motor protection relays of the CM-MSx range protect motors with
PTC sensors against high temperature. These sensors are incorporated in the
motor windings thus measuring the motor heat directly.
Monitoring the motorThe thermistor motor protection relay measures the resistance
of the PTC sensors which reflects the internal motor tempera-
ture permanently.
If the temperature in the motor windings rises excessively and
reaches the nominal response temperature (NRT), the therm-
istor motor protection relay detects this situation and the
output relay switches off.
By doing so the motor contactor gets triggered and switches
off the motor.
CM-MSS functionality video
Characteristics CM-MSS1)
– Different types of contacts available
– 1 x 2 c/o (SPDT) contacts
– 2 x 1 c/o (SPDT) contact
– 1 n/o and 1 n/c contact
– 1 or 2 measuring circuits
– Different types of reset functions
– Automatic
– Manual
– Remote
– Rated control supply voltages
– 24 V AC/DC
– 24-240 V AC/DC
– 110-130 V AC, 220-240 V AC
– Approvals / Marks
A C R K E I1) / a b
Characteristics CM-MSE – Auto reset
– Connection of several sensors (max. 6 sensors
connected in series)
– Monitoring of bimetals
– 1 n/o contact
– Excellenct cost / performance ratio
Features 1)
– Additional functions:
– Dynamic interrupted wire detection
– Short-circuit monitoring of the sensor circuit
– Non-volatile fault storage
– Single or sum evaluation
– Easy configuration via DIP switches
– LEDs to distinguish between different failure causes
– Screw connection technology or Easy Connect Technology
available
– Test/Reset button available
1) Depending on device the characteristics vary, for detailled overview see „Selection
table CM-MSx range“ on page 89.
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/88
2
Thermistor motor protection relays
Operating controls
1 Test / Reset button
Reset - only possible if measured value < switch-on resistance
2 Indication of operational states with LEDs
U: green LED - Status indication of control supply voltage V
Control supply voltage applied
F: red LED - Fault message
R: yellow LED - Status indication of the output relay
3 Marker label / DIP switches (depending on device) e.g. i Single evaluation 2 x 1 c/o (SPDT) contact
j Accumulative evaluation 1 x 2 c/o (SPDT) contacts
y Short-circuit detection de-activated
x Short-circuit detection activated
f Non-volatile fault storage activated
e Non-volatile fault storage de-activated
1
3
2
2C
DC
25
3 0
01
F0
01
5
Operational state U: green LED F: red LED R: yellow LEDAbsence of control supply voltage OFF OFF OFF
No fault V OFF V
Short circuit V Y OFF
Interrupted wire V Z OFF
Measuring circuit 1: Overtemperature V V OFF
Measuring circuit 2: Overtemperature V W OFF
Test function X OFF OFF
Fault rectified but not confirmed V -- 1) X
Change of configuration not confirmed V OFF X
Control supply voltage not within the tolerance range X V OFF
Internal fault 2) OFF W W
Internal fault 2) X X X
LEDs, status information and fault messages CM-MSS
1) Depending on the fault with the highest priority 2) Restart the device. If after restart the same fault is indicated, replace the device.
In case of several faults, the fault with the higher priority is shown. The reset can be made after rectification and confirmation of the last fault.
2/89 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Thermistor motor protection relays
Selection table CM-MSx range
Ord
er c
od
e
1S
VR
55
08
05
R9
30
0
1S
VR
55
08
00
R9
30
0
1S
VR
55
08
01R
93
00
1S
VR
74
07
20
R14
00
1S
VR
73
07
20
R14
00
1S
VR
74
07
00
R0
10
0
1S
VR
73
07
00
R0
10
0
1S
VR
74
07
00
R2
10
0
1S
VR
73
07
00
R2
10
0
1S
VR
74
07
22
R14
00
1S
VR
73
07
22
R14
00
1S
VR
74
07
00
R0
20
0
1S
VR
73
07
00
R0
20
0
1S
VR
74
07
00
R2
20
0
1S
VR
73
07
00
R2
20
0
1S
VR
74
0712
R14
00
1S
VR
73
0712
R14
00
1S
VR
74
0712
R0
20
0
1S
VR
73
0712
R0
20
0
1S
VR
74
0712
R2
20
0
1S
VR
73
0712
R2
20
0
1S
VR
74
0712
R12
00
1S
VR
73
0712
R12
00
1S
VR
74
0712
R13
00
1S
VR
73
0712
R13
00
Typ
e
CM
-MS
E
CM
-MS
E
CM
-MS
E
CM
-MS
S.1
1P
CM
-MS
S.1
1S
CM
-MS
S.1
2P
CM
-MS
S.1
2S
CM
-MS
S.1
3P
CM
-MS
S.1
3S
CM
-MS
S.2
1P
CM
-MS
S.2
1S
CM
-MS
S.2
2P
CM
-MS
S.2
2S
CM
-MS
S.2
3P
CM
-MS
S.2
3S
CM
-MS
S.3
1P
CM
-MS
S.3
1S
CM
-MS
S.3
2P
CM
-MS
S.3
2S
CM
-MS
S.3
3P
CM
-MS
S.3
3S
CM
-MS
S.4
1P
CM
-MS
S.4
1S
CM
-MS
S.5
1P
CM
-MS
S.5
1S
Characteristics
ATEX approval
Number of sensor circuits 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2
Single or accumulative evaluation
Number of LEDs 3 3 2 2 2 2 3 3 2 2 2 2 3 3 3 3 3 3 3 3 3 3
Contacts
1 c/o (SPDT) contact
2 c/o (SPDT) contacts
1 n/o
1 n/c and 1 n/o
2 x 1 c/o or 1 x 2 c/o contacts, configurable
Reset
Manual
Remote
Auto 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 2) 2)
Test button
Functions
Short-circuit detection
Short-circuit detection, configurable
Dynamic interrupted wire detection
Non-volatile fault storage
Non-volatile fault storage, configurable
Rated control supply voltage US
24 V AC
110-130 V AC
220-240 V AC
24-240 V AC/DC
24 V AC/DC
110-130 V AC, 220-240 V AC
Connection type
Push-in terminals
Double-chamber cage connection terminals
1) For automatic reset, connect terminals S1 to T2.2) For automatic reset, connect terminals S1 to 1T2/2T2.
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/90
2
Thermistor motor protection relays
Ordering details
DescriptionThe thermistor motor protection relays CM-MSx are used to control motors equipped with
PTC temperature sensors. The PTC temperature sensors are incorporated in the motor wind-
ings to measure the motor heating. This enables direct control and evaluation of various oper-
ating conditions. Depending on the products also ATEX approvals for use in hazardous areas
are availabe.
ABB also offers PTC temperature sensors C011 (according to DIN 44081) which are suitable
for embedding in motor windings.
Ordering details CM-MSxRated control supply voltage
Output Function Type Order code Price
1 pce
Weight(1 pce)
kg (lb)
24 V AC
1 n/o Autoreset
CM-MSE 1SVR550805R9300 0.11 (0.24)
110-130 V AC CM-MSE 1SVR550800R9300 0.11 (0.24)
220-240 V AC CM-MSE 1SVR550801R9300 0.11 (0.24)
24-240 V AC/DC 1 n/c, 1 n/o
Autoreset, dynamic interrupted wire detection, non-volatile fault storage, ATEX approval
CM-MSS.11P 1SVR740720R1400 0.119 (0.263)
CM-MSS.11S 1SVR730720R1400 0.127 (0.280)
24 V AC/DC 1 c/o (SPDT) Autoreset
CM-MSS.12P 1SVR740700R0100 0.105 (0.231)
CM-MSS.12S 1SVR730700R0100 0.113 (0.249)
110-130 V AC, 220-240 V AC
1 c/o (SPDT) Autoreset
CM-MSS.13P 1SVR740700R2100 0.147 (0.324)
CM-MSS.13S 1SVR730700R2100 0.155 (0.342)
24-240 V AC/DC 1 n/c, 1 n/o
Autoreset, dynamic interrupted wire detection, non-volatile fault storage, short-circuit detection, ATEX approval
CM-MSS.21P 1SVR740722R1400 0.118 (0.260)
CM-MSS.21S 1SVR730722R1400 0.126 (0.278)
24 V AC/DC 2 c/o (SPDT) Auto, manual or remote reset
CM-MSS.22P 1SVR740700R0200 0.121 (0.267)
CM-MSS.22S 1SVR730700R0200 0.132 (0.291)
110-130 V AC, 220-240 V AC
2 c/o (SPDT) Auto, manual or remote reset
CM-MSS.23P 1SVR740700R2200 0.163 (0.359)
CM-MSS.23S 1SVR730700R2200 0.174 (0.384)
24-240 V AC/DC 1 n/c, 1 n/o
Auto, manual or remote reset, dynamic interrupted wire detection, non-volatile fault storage, short-circuit detection, ATEX approval
CM-MSS.31P 1SVR740712R1400 0.120 (0.265)
CM-MSS.31S 1SVR730712R1400 0.128 (0.282)
24 V AC/DC 2 c/o (SPDT)Auto, manual or remote reset, dynamic interrupted wire detection, short-circuit detection, ATEX approval
CM-MSS.32P 1SVR740712R0200 0.120 (0.265)
CM-MSS.32S 1SVR730712R0200 0.130 (0.287)
110-130 V AC, 220-240 V AC
2 c/o (SPDT)
CM-MSS.33P 1SVR740712R2200 0.162 (0.357)
CM-MSS.33S 1SVR730712R2200 0.172 (0.379)
24-240 V AC/DC
2 c/o (SPDT)
Auto, manual or remote reset, dynamic interrupted wire detection, non-volatile fault storage, short-circuit detection, ATEX approval
CM-MSS.41P 1SVR740712R12000.130 (0.287)
CM-MSS.41S 1SVR730712R12000.141 (0.311)
2x1 c/o or, 1x2 c/o
Auto, manual or remote reset, dynamic interrupted wire detection, non-volatile fault storage, short-circuit detection, accumulative evaluation, ATEX approval
CM-MSS.51P 1SVR740712R13000.135 (0.298)
CM-MSS.51S 1SVR730712R13000.145 (0.320)
2C
DC
25
1 0
14
V0
01
4
CM-MSS.51S
2/91 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Thermistor motor protection relays
Ordering details - PTC temperature sensors C011
1S
VC
11
0 0
00
F0
53
1
Temperature sensor characteristics
Technical dataCharacteristic data Sensor type C011Cold-state resistance 50 -100 � at 25 °C
Warm-state resistance ± 5 up to 6 K of rated response temperature T
NF10 000 �
Thermal time constant, sensor open 1) < 5 s
Permitted ambient temperature +180 °C
Rated response tempera-
ture � tolerance TNF � �TNF
PTC resistance R
from -20 °C to TNF
- 20 K
PTC resistance R2) at PTC temperatures of:
TNF - �TNF
(UPTC � 2.5 V)
TNF + �TNF
(UPTC � 2.5 V)
TNF + 15 K
(UPTC � 7.5 V)
70 �5 °C
� 100 �
� 570 � � 570 � -80 �5 °C
90 �5 °C
� 550 � � 1330 � � 4000 �
100 �5 °C
110 �5 °C
120 �5 °C
130 �5 °C
140 �5 °C
150 �5 °C
160 �5 °C
170 �7 °C � 570 � � 570 � -
1) Not embedded in windings. 2) For triple temperature sensor take values x 3.
-20
°C
101
102
103
104
TNF
- 20
KTN
F -
5 K
T NF
TNF
+ 5
KTN
F +
15
K
RPTC
[�]
TPTC [°C]
2C
DC
252 0
68 F
0208
Ordering detailsRated response temperature TNF
Color coding Type Order code Price
1 pce
Weight(1 pce) kg (lb)
70 °C white-brown C011-701) GHC0110003R0001 0.02 (0.044)
80 °C white-white C011-801) GHC0110003R0002 0.02 (0.044)
90 °C green-green C011-901) GHC0110003R0003 0.02 (0.044)
100 °C red-red C011-1001) GHC0110003R0004 0.02 (0.044)
110 °C brown-brown C011-1101) GHC0110003R0005 0.02 (0.044)
120 °C gray-gray C011-1201) GHC0110003R0006 0.02 (0.044)
130 °C blue-blue C011-1301) GHC0110003R0007 0.02 (0.044)
140 °C white-blue C011-1401) GHC0110003R0011 0.02 (0.044)
150 °C black-black C011-1501) GHC0110003R0008 0.02 (0.044)
160 °C blue-red C011-1601) GHC0110003R0009 0.02 (0.044)
170 °C white-green C011-1701) GHC0110003R0010 0.02 (0.044)
150 °C black-black C011-3-1502) GHC0110033R0008 0.05 (0.11)
1) Temperature sensor C011, standard
version acc. to DIN 440812) Triple temperature sensor C011-3
DescriptionThe PTC temperature sensors (temperature-dependent with positive temperature coefficient)
are selected by the manufacturer of the motor depending on:
– the motor insulation class according to IEC/EN 60034-11,
– the special characteristics of the motor, such as the conductor cross-section of the wind-
ings, the permissible overload factor etc.
– special conditions prescribed by the user, such as the permissible ambient temperature,
risks resulting from locked rotor, extent of permitted overload etc.
One temperature sensor must be embedded in each phase winding. For instance, in case of
three-phase squirrel cage motors, three sensors are embedded in the stator windings. For
pole-changing motors with one winding (Dahlander connection), 3 sensors are also sufficient.
Pole-changing motors with two windings, however, require The sensors are suitable for em-
bedding in motor windings with rated operating voltages of up to 600 V AC. Conductor length:
500 mm per sensor. A 14 V varistor can be connected in parallel to protect the sensors from
overvoltage. Due to their characteristics, the thermistor motor protection relays can also be
used with PTC temperature sensors of other manufacturers which comply with DIN 44 081
and DIN 44 082 6 sensors.
If an additional warning is required before the motor is switched off, separate sensors for a
correspon dingly lower temperature must be embedded in the winding. They have to be con-
nected to a second control unit.
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/92
2
Thermistor motor protection relays
Technical data
Technical dataData at T
a = 25 °C and rated values, unless otherwise indicated
Supply circuit - Input circuit CM-MSS.x1 CM-MSS.x2 CM-MSS.x3
Rated control supply voltage Us A1-A2 24-240 V AC/DC 24 V AC/DC 220-240 V AC
A2-A3 - - 110-130 V AC
Rated control supply voltage Us tolerance -15...+10 %
Rated frequency 15-400 Hz 50-60 Hz
Electrical insulation between supply circuit and measuring circuit yes no yes
Power failure buffering time 20 ms
Supply circuit - Measuring circuit / Sensor circuit
Number of circuits 1 (CM-MSS.51: 2)
Sensor type PTC type A (DIN/EN 44081, DIN/EN 44082)
Max. total resistance of sensors connected in series, cold state < 750
Overtemperature monitoring
switch-off resistance (relay de-energizes) 2.83 k � 1% (CM-MSS.12 /.13 /.22 /.23: 2.7 k � 5%)
switch-on resistance (relay energizes) 1.1 k � 1% (CM-MSS.12 /.13 /.22 /.23: 1.2 k � 5%)
Maximum voltage in sensor circuit 1.33 k 2.5 V
4 k 3.7 V
� k 5.5 V
Maximum current in sensor circuit 3.7 mA
Maximum sensor cable length 2 x 100 m at 0.75 mm2, 2 x 400 m at 2.5 mm2
Accuracy within the rated control supply voltage tolerance 0.50 % (CM-MSS.12 /.13 /.22 /.23: 5 %)
Accuracy within the temperature range 0.01 %/K (CM-MSS.12 /.13 /.22 /.23: 0.5 %/K)
Repeat accuracy (constant parameters) on request
Reaction time of the safety function < 100 ms
Hardware fault tolerance (HFT) 0
Control circuit
Control function see „Selection table CM-MSx range“ on page 89
Maximum no-load voltage 5.5 V
Max. current 0.6 mA (CM-MSS.12 /.13 /.22 /.23: 1.2 mA)
Maximum cable length 2 x 100 m at 0.75 mm², 2 x 400 m at 2.5 mm²
Indication of operational states
Control supply voltage U LED green
Relay status R LED yellow
Fault message F LED red
Output circuit
Kind of output see „Selection table CM-MSx range“ on page 89
Operating principle closed-circuit principle
Contact material AgNi alloy, Cd free
Rated operational voltage Ue (IEC/EN 60947-1) 250 V AC
Minimum switching voltage / Minimum switching current 24 V / 10 mA
Maximum switching voltage / Maximum switching current see data sheet
Rated operating current Ie
(IEC/EN 60947-5-1)AC-12 (resistive) at 230 V 4 A
AC-15 (inductive) at 230 V 3 A
DC-12 (resistive) at 24 V 4 A
DC-13 (inductive) at 24 V 2 A
AC Rating (UL 508) utilization category (Control Circuit Rating Code) B 300
maximum rated operational voltage 250 V AC
maximum continuous thermal current at B 300 4 A
maximum making/breaking apparent power at B 300 3600/360 VA
Mechanical lifetime 30 x 106 switching cycles
Electrical lifetime at AC12, 230 V AC, 4 A 0.1 x 106 switching cycles
Maximum fuse rating to achieve short-circuit protection
n/c contact 10 A fast-acting (CM-MSS.12, CM-MSS.13, CM-MSS.51: 6 A)
n/o contact 10 A fast-acting
2/93 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Thermistor motor protection relays
Technical data - CM-MSS
General data
MTBF on request
Duty time 100 %
Dimensions (W x H x D) product dimensions 22.5 x 85.6 x 103.7 mm (0.89 x 3.37 x 4.08 in)
packaging dimensions 97 x 109 x 30 mm (3.82 x 4.29 x 1.18 in)
Weight see „Ordering details“ on page 90
Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool
Mounting position any
Minimum distance to other units vertical 10 mm (0.394 in) if switching current > 2 A
horizontal 10 mm (0.394 in) if switching current > 2 A
Material of housing UL 94 V-0
Degree of protection housing IP50
terminals IP20
Electrical connection Screw connection technology Easy Connect Technology (push-in)
Wire size fine-strand with(out) wire end ferrule
1 x 0.5-2.5 mm2 (1 x 20-14 AWG) 2 x 0.5-1.5 mm2 (2 x 20-16 AWG)
2 x 0.5-1.5 mm2 (2 x 20-16 AWG)
rigid 1 x 0.5-4 mm2 (1 x 20-12 AWG) 2 x 0.5-2.5 mm2 (2 x 20-14 AWG)
2 x 0.5-1.5 mm2 (2 x 20-16 AWG)
Stripping length 8 mm (0.32 in)
Tightening torque 0.6-0.8 Nm (5.31-7.08 lb.in) -
Wire end ferrule according to DIN 46228-1-A, DIN 46228-4-E
-
Environmental data
Ambient temperature ranges operation -25 °C...+60 °C
storage -40 °C...+85 °C
Damp heat, cyclic (IEC/EN 60068-2-30) 6 x 24 h cycle, 55 °C, 95 % RH
Climatic category (IEC/EN 60721-3-3) 3K5 (no condensation, no ice formation)
Vibration, sinusoidal (IEC/EN 60255-21-1) Class 2
Shock (IEC/EN 60255-21-2) Class 2
Isolation data
Rated insulation voltage
Ui (IEC/EN 60947-1,
IEC/EN 60664-1)
Supply circuit / Measuring circuit1) 300 V AC (CM-MSS.x2: n/a)
Supply circuit / Output circuits 300 V AC
Measuring circuit1) / Output circuits 300 V AC
Output circuit 1 / Output circuit 2 300 V AC
Rated impulse
withstand voltage
Uimp
(IEC/EN 60947-1,
IEC/EN 60664-1)
Supply circuit / Measuring circuit1) 4 kV / 6 kV (CM-MSS.x2: n/a)
Supply circuit / Output circuits 4 kV / 6 kV
Measuring circuit1) / Output circuits 4 kV / 6 kV
Output circuit 1 / Output circuit 2 4 kV
Basic insulation (IEC/EN 60664-1)
Supply circuit / Measuring circuit1) 600 V AC (CM-MSS.x2: n/a)
Supply circuit / Output circuits 600 V AC
Measuring circuit1) / Output circuits 600 V AC
Output circuit 1 / Output circuit 2 300 V AC
Test voltage, routine test (IEC/EN 60255-27)
Supply circuit / Measuring circuit1) 2.5 kV, 50 Hz, 1 min. (CM-MSS.x2: n/a)
Supply circuit / Output circuits 2.5 kV, 50 Hz, 1 min.
Measuring circuit1) / Output circuits 2.5 kV, 50 Hz, 1 min.
Test voltage, type test (IEC/EN 60255-27)
Supply circuit / Measuring circuit1) 6 kV / 1.2 - 50 μs (CM-MSS.x2: n/a)
Supply circuit / Output circuits 6 kV / 1.2 - 50 μs
Measuring circuit1) / Output circuits 6 kV / 1.2 - 50 μs
Output circuit 1 / Output circuit 2 6 kV / 1.2 - 50 μs
Protective separation (IEC/EN 61140, IEC/EN 50178)
Supply circuit / Measuring circuit1) yes, up to 300 V
Supply circuit / Output circuits yes (CM-MSS.x2: n/a)
Measuring circuit1) / Output circuits yes
Output circuit 1 / Output circuit 2 no
Pollution degree (IEC/EN 60664-1) 3
Overvoltage category (IEC/EN 60664-1) III
1) Potential of measuring circuit = Potential of control circuit
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/94
2
Thermistor motor protection relays
Technical data - CM-MSS
Standards
Product standard IEC/EN 60255-1; IEC/EN 60947-8
Low Voltage Directive 2006/95/EC
EMC directive 2004/108/EC
ATEX directive 94/9/EC (only ATEX variants „Selection table CM-MSx range“ on page 89)
RoHS directive 2011/65/EC
Electromagnetic compatibility
Interference immunity to IEC/EN 61000-6-1, IEC/EN 61000-6-2
electrostatic discharge IEC/EN 61000-4-2 Level 3, 6 kV contact discharge, 8 kV air discharge
radiated, radio-frequency, electromagnetic field
IEC/EN 61000-4-3 Level 3, 10 V/m (1 GHz), 3 V/m (2 GHz), 1 V/m (2.7 GHz)
electrical fast transient / burst IEC/EN 61000-4-4 Level 3, 2 kV / 5 kHz
surge IEC/EN 61000-4-5 Level 3, Installation class 3, supply circuit and measuring circuit 1 kV L-L, 2 kV L-N
conducted disturbances, induced by radio-frequency fields
IEC/EN 61000-4-6 Level 3, 0.15-80 MHz, 10 V, 80 % AM (1kHz)
voltage dips, short interruptions and voltage variations
IEC/EN 61000-4-11 Class 3
harmonics and interharmonics IEC/EN 61000-4-13 Class 3
Additional interference immunity according to product standard EN 60255-1 (reference on EN 60255-26_2011)
radiated, radio-frequency, electromagnetic field
IEC/EN 61000-4-3 10 V/m (80 MHz - 3 GHz)
conducted disturbances, induced by radio-frequency fields
IEC/EN 61000-4-6 10 V at stated frequencies
damped oscillatory waves IEC/EN 61000-4-18 Signal lines, symmetric coupling: 1 kV peak voltagePower supply, asymmetric coupling: 2.5 kV peak voltage
Interference emissions IEC/EN 61000-6-3, IEC/EN 61000-6-4
high-frequency radiated IEC/CISPR 22, EN 55022 Class B
high-frequency conducted IEC/CISPR 22, EN 55022 Class B
high-frequency radiated Germanischer Lloyd increased requirements in the emergency call frequency band
2/95 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Thermistor motor protection relays
Technical data - CM-MSE
Technical dataData at T
a = 25 °C and rated values, unless otherwise indicated
Supply circuit - Input circuit CM-MSERated control supply voltage U
s power consumption 1SVR550805R9300 24 V AC approx. 1.5 A
1SVR550800R9300 110-130 V AC approx. 1.5 A
1SVR550801R9300 220-240 V AC approx. 1.5 A
Rated control supply voltage Us tolerance -15...+10 %
Rated frequency 50-60 Hz
Measuring circuitMonitoring function T1-T2 temperature monitoring by means of PTC sensors
Number of sensor circuits 1
Sensor circuitTemperature threshold (relay de-energizes) 2.7-3.7 k
Temperature hysteresis (relay energizes) 1.7-2.3 k
Short-circuit threshold (relay de-energizes) <18
Short-circuit hysteresis (relay energizes) >45
Maximum total resistance of sensors connected in series (cold state) �1.5 kMaximum sensor cable length for short-circuit detection 2 x 100 m at 0.75 mm2, 2 x 400 m at 2.5 mm2
Response time <100 ms
Output circuitKind of output 13-14 1 n/o contact
Operational principle closed-circuit principle (output relay de-energizes if the measured value exceeds/drops below the adjusted threshold)
Contact material AgCdO
Rated voltage VDE 0110, IEC 664-1, IEC 60947-1 250 V
Maximum switching voltage 250 V
Rated operating current Ie
(IEC/EN 60947-5-1)AC-12 (resistive) at 230 V 4 A
AC-15 (inductive) at 230 V 3 A
DC-12 (resistive) at 24 V 4 A
DC-13 (inductive) at 24 V 2 A
AC Rating (UL 508) utilization category (Control Circuit Rating Code) B 300
maximum rated operational voltage 300 V AC
maximum continuous thermal current at B 300 5 A
maximum making/breaking apparent power at B 300 3600/360 VA
Mechanical lifetime 30 x 106 switching cycles
Electrical lifetime at AC12, 230 V AC, 4 A 0.1 x 106 switching cycles
Maximum fuse rating to achieve short-circuit protection
n/c contact 10 A fast-acting
n/o contact 10 A fast-acting
General dataDimensions (W x H x D) 22.5 x 78 x 78.5 mm (0.89 x 3.07 x 3.09 in)
Duty time 100 %
Weight approx. 0.11 kg (0.24 lb)
Mounting position any
Degree of protection housing / terminals IP50 / IP20
Ambient temperature range operation -20...+60 °C
storage -40...+85 °C
Mounting DIN rail (IEC/EN 60715)
Electrical connectionWire size fine strand with wire end ferrule 2 x 1.5 mm2 (2 x 16 AWG)
fine strand without wire end ferrule 2 x 0.75-1.5 mm2 (2 x 18-16 AWG)
rigid 2 x 1-1.5 mm2 (2 x 18-16 AWG)
Stripping length 2 x 0.75-1.5 mm2 (2 x 18-16 AWG)
Tightening torque 0.6-0.8 Nm (5.31-7.08 lb.in)
StandardsProduct standard IEC 255-6, EN 60255-6
Low Voltage Directive 2006/95/EC
EMC Directive 2004/108/EC, 91/263/EEC, 92/31/EEC, 93/68/EEC, 93/67/EEC
Electromagnetic compatibilityelectrostatic discharge IEC/EN 61000-4-2 Level 3 (6 kV / 8 kV)
radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 Level 3 (10 V/m)
electrical fast transient /burst IEC/EN 61000-4-4 Level 3 (2 kV / 5 kHz)
surge IEC/EN 61000-4-5 Level 3/4 (1/2 kV)
conducted disturbances, induced by radio-frequency fields
IEC/EN 61000-4-6 Level 3 (10 V)
Operational reliability (IEC 68-2-6) 6 g
Resistance to vibration (IEC 68-2-6) 10 g
Environmental testing (IEC 68-2-30) 24 h cycle time, 55 °C, 93 % rel., 96 h
Electromagnetic compatibilityRated voltage between supply, measuring and output circuit 250 V
Rated impulse withstand voltage between all isolated circuits 4 kV / 1.2 - 50 μs
Test voltage between all isolated circuits 2.5 kV, 50 Hz, 1 min.
Pollution degree 3
Overvoltage category III
2
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/96
Thermistor motor protection relays
Notes
2/97 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Thermistor motor protection relays
Connection diagrams
A1 13 21
T2 T1
14 22 A2
ϑ
T2
T1 A1 14
13 21
22
A2
A1 11 21
T2 T1
24 22 S1
14 12 A2
ϑ
T2
S1
T1 A1
A2 12
11 21
14 22 24
A1 11
T2 T1
14 12 A2
T2
T1 A1
A2 12
11
14
ϑ
A1
A3
11 21
T2 T1
14 12
24 22 S1
A2
S1 ϑ
T2
T1 A1 A3
A2 22
21
2412
11
14
A1
A3
11
T2 T1
14 12 A2
ϑ
T2
T1 A1 A3
A2 12
11
14
A1 11 21
1T1 1T2/2T2 2T1
24 22 S1
14 12 A2
ϑ ϑS1 S1
A1 11
12 14
21
22 24A2
1T1 A12T1
1T2/2T2 A21T2/2T2
A1
13
T2T1
14 A2
ϑ
T2
T1 A1
14
13
A2
A1 13 21
T2S1 T1
14 22 A2
ϑ
T2
T1 A1 14
13 21
22
A2
S1
CM-MSS.11, CM-MSS.21 CM-MSS.12 CM-MSS.13 CM-MSS.31
CM-MSS.22, CM-MSS.32, CM-MSS.41
CM-MSS.23, CM-MSS.33 CM-MSS.51 CM-MSE
A1 – A2 Control supply voltage
13 – 14 n/o contact
21 – 22 n/c contact
T1 – T2 Measuring circuit
A1 – A2 Control supply voltage
220-240 V AC
A2 – A3 Control supply voltage
110-130 V AC
11 – 12/14 c/o contact
T1 – T2 Measuring circuit
A1 – A2 Control supply voltage
13 – 14 n/o contact
21 – 22 n/c contact
S1 – T2
(jumpered)
Automatic reset
T1 – T2 Measuring circuit
A1 – A2 Control supply voltage 24 V AC/DC
11 – 12/14 1st c/o (SPDT) contact
21 – 22/24 2nd c/o (SPDT) contact
S1 – T2 ( jumpered)
Automatic reset
T1 – T2 Measuring circuit
A1 – A2 Control supply voltage 220-240 V AC
A2 – A3 Control supply voltage 110-130 V AC
11 – 12/14 1st c/o (SPDT) contact
21 – 22/24 2nd c/o (SPDT) contact
S1 – T2 ( jumpered)
Automatic reset
T1 – T2 Measuring circuit
A1 – A2 Control
supply voltage
220-240 V AC
11 – 12/14 1st c/o (SPDT)
contact
21 – 22/24 2nd c/o (SPDT)
contact
S1 – 1T2/2T2
(jumpered)
Automatic reset
1T1 – 1T2/2T2 Measuring circuit 1
2T1 – 1T2/2T2 Measuring circuit 2
A1 – A2 Control supply voltage
24 V AC
T1-T2 Sensor circuit
13-14 Output contact -
Closed circuit principle
A1 – A2 Control supply voltage
11 – 12/14 c/o contact
T1 – T2 Measuring circuit
2C
DC
25
2 0
18
F0
01
42
CD
C 2
52
01
9 F
00
14
2C
DC
25
2 0
21
F0
01
4
2C
DC
25
2 0
17
F0
01
4
1S
VC
11
0 0
00
F0
14
0
2C
DC
25
2 0
22
F0
01
4
2C
DC
25
2 0
20
F0
01
4
2C
DC
25
2 0
47
F0
01
4
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/98
2
Thermistor motor protection relays
Circuit diagram
M 3~
V+
T2
T1
A1
μC
V-
t
A2
21
14
22
13
M 3~
V+
T2
T1
A1
V-
t
A2
14
11
12
M 3~
V+
T2
T1
A1 or A3
V-
t
A2
14
11
12
M 3~
V+
T2
T1
A1
μC
V-
t
A2S1
21
14
22
Test /
Reset
13
M 3~
V+
T2
T1
A1 or A3
V-
t
A2S1
24
11
21
22
14
12
Reset
M 3~
V+
T2
T1
A1
V-
t
A2S1
24
11
21
22
14
12
Reset
M 3~
V+
T2
T1
A1
μC
V-
t
A2S1
24
11
21
22
14
12
Test /
Reset
M 3~
V+
T2
T1
A1 or A3
μC
V-
t
A2S1
24
11
21
22
14
12
Test /
Reset
M 3~
M 3~
V+
1T2/2T2
2T1
1T1
A1
μC
V-
t
t
A2S1
24
11
21
22
14
12
Test /
Reset
CM-MSS.11, CM-MSS.21
CM-MSS.31CM-MSS.23CM-MSS.22
CM-MSS.12 CM-MSS.13
CM-MSS.32, CM-MSS.41
CM-MSE
CM-MSS.33 CM-MSS.51
2C
DC
25
3 0
23
F0
01
42
CD
C 2
53
02
6 F
00
14
2C
DC
25
3 0
15
F0
01
4
1S
VC
11
0 0
00
F0
14
1
2C
DC
25
3 0
29
F0
01
4
2C
DC
25
3 0
16
F0
01
4
2C
DC
25
3 0
27
F0
01
4
2C
DC
25
3 0
28
F0
01
4
2C
DC
25
3 0
24
F0
01
4
2C
DC
25
3 0
25
F0
01
4
2/99 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Temperature monitoring relays
Product group picture
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/100
2
Temperature monitoring relays
Table of contents
Temperature monitoring relays
Benefits and advantages, Applications 2/99
Operating controls 2/100
Selection 2/101
Ordering details 2/102
Function diagrams 2/103
Overview, Functional description and diagrams 2/104
Connection diagrams, Resistance thermometer sensors 2/105
Technical data - CM-TCS.xx 2/106
Technical data - C51x 2/108
2/101 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Temperature monitoring relays
Benefits and advantages, Applications
Characteristics CM-TCS – Adjustable sensor type: PT100
– Functionality like overtemperature monitoring, under-
temperature monitoring, temperature window monitoring
configurable
– All configurations and adjustments by front-face operating
elements
– Precise adjustment with direct reading scales
– One or two threshold values
– Hysteresis 2...20 % adjustable
– Operating temperature range -40...+60 °C
– 1 x 2 c/o or 2 x 1 c/o configurable
– Open- or closed-circuit principle configurable
– Short-circuit monitoring and interrupted wire detection
– 22.5 mm (0.89 in) width
– LEDs for status indication
Characteristics C512 + C513 – Adjustable sensor types: PT100, PT1000, KTY83, KTY84,
NTC-B57227-K333-A1
– Measuring principle for 2-wire and 3-wire sensors
– Temperature monitor for 1-3 sensor circuits
– Adjustable over-, undertemperature monitoring or range
monitoring function
– 2 thresholds
– Hysteresis for both thresholds (1-99 Kelvin)
– Adjustable time delay from 0-999 s affects to both thresh-
olds
– Storage function selectable via external signal (Y1-Y2)
– Non volatile storage of parameter settings
– 1 n/o (for wire-break and short-circuit detection) and 2 c/o
– Multifunctional digital display
– 3 LEDs for status indication
– Open- or closed-circuit principle selectable
– 45 mm wide housing with 24 terminals
C513 – Temperature monitor for 1-3 sensor circuits
– In the 3-sensor version the status of the single sensors
is displayed if the temperature exceeds or falls below the
threshold. This way it can be easily determined which one
of the connected sensors has exceeded or dropped below
either one or both threshold values.
C512 – Temperature monitor for 1 sensor circuit
Functional descriptionThe temperature monitoring relays CM-TCS monitor overtem-
perature, undertemperature, or temperatures between two
threshold values (window monitoring) with PT100 sensor. As
soon as the temperature falls below or exceeds the threshold
value the output relays change their positions according to
the configured functionality and the front-face LEDs display
the current status. Regardless of the selected configuration,
the device is monitoring its measuring circuit for interrupted
wires or short-circuits.
OverviewThe temperature monitoring relays can be used for tempera-
ture measurement in solid, liquid and gaseous media. The
temperature is acquired by the sensor in the medium, evalu-
ated by the device and monitored to determine whether it is
within an operating range (range monitoring function) or has
exceeded or fallen below a threshold.
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/102
2
Temperature monitoring relays
Operating controls
4
1
2
3
5
1 Adjustment of the hysteresis for threshold value t1
2 Adjustment of the threshold value t1
3 Indication of operational states U: green LED – status indication of control supply voltage
t: red LED – fault message, state of measuring input
R: yellow LED – status indication of the output relays
4 Adjustment of the hysteresis for threshold value t2
5 Adjustment of the threshold value t2
6 DIP switch functions / marker label (on page 2/104) p Overtemperature monitoring
q Undertemperature monitoring
r Temperature window monitoring activated
s Temperature window monitoring de-activated
g Closed-circuit principle
h Open-circuit principle
i 2 x 1 c/o (SPDT) contact
j 1 x 2 c/o (SPDT) contacts
2C
DC
25
3 0
19
F0
01
3
2/103 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Temperature monitoring relays
Selection
Ord
er n
um
ber
1S
VR
73
0 7
40
R910
0
1S
VR
74
0 7
40
R910
0
1S
VR
73
0 7
40
R010
0
1S
VR
74
0 7
40
R010
0
1S
VR
73
0 7
40
R9
20
0
1S
VR
74
0 7
40
R9
20
0
1S
VR
73
0 7
40
R0
20
0
1S
VR
74
0 7
40
R0
20
0
1S
VR
73
0 7
40
R9
30
0
1S
VR
74
0 7
40
R9
30
0
1S
VR
73
0 7
40
R0
30
0
1S
VR
74
0 7
40
R0
30
0
1S
AR
70
0 1
00
R0
00
5
1S
AR
70
0 1
00
R0
010
1S
AR
70
0 1
10
R0
010
Typ
e
CM
-TC
S.2
1S
CM
-TC
S.2
1P
CM
-TC
S.1
1S
CM
-TC
S.1
1P
CM
-TC
S.2
2S
CM
-TC
S.2
2P
CM
-TC
S.1
2S
CM
-TC
S.1
2P
CM
-TC
S.2
3S
CM
-TC
S.2
3P
CM
-TC
S.1
3S
CM
-TC
S.1
3P
C51
2-2
4
C51
2-W
C51
3-W
Rated control supply voltage Us
24 V AC/DC � � � � � � �
24-240 V AC/DC � � � � � � � �
Technology
analogue � � � � � � � � � � � �
digital � � �
Sensor circuits (2 or 3 wire)
number of temperature sensors 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3
number of thresholds 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3
Sensor type
PT100 � � � � � � � � � � � � � � �PT100, KTY83, KTY84, NTC, PT1000 � � �Measuring temperature range
-50...+50 °C � � � �0...+100 °C � � � �0...+200 °C � � � �-50...+500 °C � � �Monitoring function
overtemperature � � � � � � � � � � � � � � �undertemperature � � � � � � � � � � � � � � �window temperature � � � � � � � � � � � � � � �Operating principleopen or closed principle � � � � � � � � � � � � � � �Output contactsn/o 1 1 1
c/o 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/104
2
Temperature monitoring relays
Ordering details
Description
Acquisition, messaging and regulation of temperatures of solid, liquid and gaseous media in
processes and machines via PT100, PT1000, KTY83, KTY84 or NTC sensors.
ABB offers different temperature monitoring relays to meet the needs of your application:
Ordering details - Temperature monitoring relays C51x range with display and digital setupRated control supply voltage
Measuringrange
Type 2) Order code Price
1 pce
Weight(1 pce) kg (lb)
24 V AC/DC
-50...+500 °C 1)
C512-24 1SAR700100R0005 0.32 (0.71)
24-240 V AC/DC C512-W 1SAR700100R0010 0.33 (0.73)
24-240 V AC/DC C513-W 1SAR700110R0010 0.34 (0.75)
Ordering details - Replaceable cover marking for digital devicesUse for Language Type Order code Price
5 pces
Weight(1 pce) kg (lb)
C512 German C512-D 1SVR700101R0100
C512 English C512-E 1SVR700102R0100
C513 German C513-D 1SVR700111R0100
C513 English C513-E 1SVR700112R0100
2C
DC
25
1 0
31
V0
01
21
SV
C 1
10
00
0 F
05
57
CM-TCS
C512, C513
1) The measuring range depends on the used sensor type:
PT100: -50...+500 °C
PT1000: -50...+500 °C
NTC: +80...+160 °C
(Typ Siemens Matsushita B57272-A333-A1 - 100 °C: 1.8 k , 25 °C: 32.762 k )
KTY84: -40...+300 °C
KTY83: -50...+175 °C
Ordering details - Temperature monitoring relays PT100 sensors, 2 or 3 wire connection, 2 thresholds adjustableRated control supply voltage
Measuringrange
Type Order code Price
1 pce
Weight(1 pce) kg (lb)
24-240 V AC/DC
-50...+50 °CCM-TCS.11S 1SVR730740R0100 0.151 (0.333)
CM-TCS.11P 1SVR740740R0100 0.140 (0.309)
0...+100 °CCM-TCS.12S 1SVR730740R0200 0.151 (0.333)
CM-TCS.12P 1SVR740740R0200 0.140 (0.309)
0...+200 °CCM-TCS.13S 1SVR730740R0300 0.151 (0.333)
CM-TCS.13P 1SVR740740R0300 0.140 (0.309)
24 V AC/DC
-50...+50 °CCM-TCS.21S 1SVR730740R9100 0.138 (0.304)
CM-TCS.21P 1SVR740740R9100 0.127 (0.280)
0...+100 °CCM-TCS.22S 1SVR730740R9200 0.138 (0.304)
CM-TCS.22P 1SVR740740R9200 0.127 (0.280)
0...+200 °CCM-TCS.23S 1SVR730740R9300 0.138 (0.304)
CM-TCS.23P 1SVR740740R9300 0.127 (0.280)
2/105 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Temperature monitoring relays
Function diagrams
CM-TCS - Overtemperature monitoring, 1 x 2 c/o contacts j
Undertemperature monitoring, 1 x 2 c/o contacts j
Temperature window monitoring, 1 x 2 c/o contacts j
Temperature window monitoring, 2 x 1 c/o contact i
Undertemperature monitoring, 2 x 1 c/o contact i
Overtemperature monitoring, 2 x 1 c/o contact i
A1-A2
11-1411-12
21-2421-22
11-1411-12
21-2421-22
closed
open
Threshold ϑ1
Hysteresis
Measured value
U: green LED
ϑ: red LED
R: yellow LED
U: green LED
ϑ: red LED
R: yellow LED
Open-circuit principle
Closed-circuit principle
A1-A2
11-1411-12
21-2421-22
11-1411-12
21-2421-22
closed
open
Hysteresis
Measured value
U: green LED
ϑ: red LED
R: yellow LED
U: green LED
ϑ: red LED
R: yellow LED
Open-circuit principle
Closed-circuit principle
Threshold ϑ2
A1-A2
11-1411-12
21-2421-22
11-1411-12
21-2421-22
closed
open
Threshold ϑ1
Hysteresis
Measured value
Threshold ϑ2
Hysteresis
Open-circuit principle
U: green LED
ϑ: red LED
R: yellow LED
Closed-circuit principle
U: green LED
ϑ: red LED
R: yellow LED
A1-A2
11-1411-12
21-2421-22
11-1411-12
21-2421-22
closed
open
Threshold ϑ1
Hysteresis
Measured value
Threshold ϑ2
Hysteresis
Open-circuit principle
U: green LED
ϑ: red LED
R: yellow LED
Closed-circuit principle
U: green LED
ϑ: red LED
R: yellow LED
A1-A2
11-1411-12
21-2421-22
11-1411-12
21-2421-22
closed
open
Threshold ϑ1
Hysteresis
Measured value
Hysteresis
Threshold ϑ2
Open-circuit principle
U: green LED
ϑ: red LED
R: yellow LED
Closed-circuit principle
U: green LED
ϑ: red LED
R: yellow LED
A1-A2
11-1411-12
21-2421-22
11-1411-12
21-2421-22
closed
open
Threshold ϑ1
Hysteresis
Measured value
Hysteresis
Threshold ϑ2
Open-circuit principle
U: green LED
ϑ: red LED
R: yellow LED
Closed-circuit principle
U: green LED
ϑ: red LED
R: yellow LED
With this configuration, settings via t2 have no influence on the operating function (t2 disabled).
Open-circuit principle:
If the measured value is correct, the output relays remain de-energized when control supply voltage is applied. If the
measured value exceeds the adjusted threshold value t1, the output relays energize. If the measured value drops
again below the adjusted threshold value t1 minus the adjusted hysteresis, the output relays de-energize.
Closed-circuit principle:
The behavior is inverse to the one with open-circuit principle.
Open-circuit principle:
If the measured value is correct, the output relays remain de-energized when control supply voltage is applied. If the
measured value exceeds the adjusted threshold value t2, output relay R2 (prewarning) energizes. If the measured
value exceeds the adjusted threshold value t1, output relay R1 (final switch-off) energizes.
If the measured value drops again below the adjusted threshold value t1 minus the adjusted hysteresis, output relay
R1 (final switch-off) de-energizes. If the measured value drops below the adjusted threshold value t2 minus the
adjusted hysteresis, output relay R2 (prewarning) de-energizes.
Closed-circuit principle:
The behavior is inverse to the one with open-circuit principle.
2C
DC
25
2 0
08
F0
20
92
CD
C 2
52
00
9 F
02
09
With this configuration, settings via t1 have no influence on the operating function (t1 disabled).
Open-circuit principle:
If the measured value is correct, the output relays remain de-energized when control supply voltage is applied. If
the measured value drops below the adjusted threshold value t2, the output relays energize. If the measured value
exceeds again the adjusted threshold value t2 plus the adjusted hysteresis, the output relays de-energize.
Closed-circuit principle:
The behavior is inverse to the one with open-circuit principle.
Open-circuit principle:
If the measured value is correct, the output relays remain de-energized when control supply voltage is applied. If the
measured value drops below the adjusted threshold value t1, output relay R1 (prewarning) energizes. If the measured
value drops below the adjusted threshold value t2, output relay R2 (final switch-off) energizes.
If the measured value exceeds again the adjusted threshold value t2 plus the adjusted hysteresis, output relay R2
(final switch-off) de-energizes. If the measured value exceeds the adjusted threshold value t1 plus the adjusted
hysteresis, output relay R1 (prewarning) de-energizes.
Closed-circuit principle:
The behavior is inverse to the one with open-circuit principle.2
CD
C 2
52
01
0 F
02
09
2C
DC
25
2 0
11
F0
20
9
Open-circuit principle:
If the measured value is correct, the output relays remain de-energized when control supply voltage is applied. If
the measured value exceeds the adjusted threshold value t1 or drops below the adjusted threshold value t2, the
output relays energize. If the measured value drops again below the adjusted threshold value t1 minus the adjusted
hysteresis or exceeds again the adjusted threshold value t2 plus the adjusted hysteresis, the output relays de-
energize.
Closed-circuit principle:
The behavior is inverse to the one with open-circuit principle.
Open-circuit principle:
If the measured value is correct, the output relays remain de-energized when control supply voltage is applied.
If the measured value exceeds the adjusted threshold value t1 or drops below the adjusted threshold value t2, output
relay R1 (> t1) or R2 (< t2) respectively energizes.
If the measured value drops again below the adjusted threshold value t1 minus the adjusted hysteresis or exceeds
again the adjusted threshold value t2 plus the adjusted hysteresis, output relay R1 (>t1) or R2 (<t2) respectively de-
energizes.
Closed-circuit principle:
The behavior is inverse to the one with open-circuit principle.
2C
DC
25
2 0
12
F0
20
92
CD
C 2
52
01
3 F
02
09
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/106
2
DIP switches CM-TCS
Position 4 1 2 3
ON
OFF
i g r p
qs
h
j
ON OFF (default)
DIP switch 1Monitoring principle
Overtemperature monitoring pIf overtemperature monitoring is selected, the CM-TCS recognizes
temperatures above the selected threshold and trips the output relay
according to the selected operating principle.
Undertemperature monitoring qIf undertemperature monitoring is selected, the CM-TCS recognizes
temperatures below the selected threshold and trips the output relay
according to the selected operating principle.
DIP switch 2
Temperature
window
monitoring
Temperature window monitoring activated rIf temperature window monitoring is selected, the CM-TCS monitors
over- and undertemperature. If temperature window monitoring is
activated, DIP switch 1 is disabled.
Temperature window monitoring de-activated sTemperature window monitoring is de-selected.
DIP switch 3
Operating principle
of the output relays
Closed-circuit principle gIf closed-circuit principle is selected, the output relays are energized.
They de-energize if a fault is occuring.
Open-circuit principle hIf open-circuit principle is selected, the output relays are deenergized.
They energize if a fault is occuring.
DIP switch 4
2 x 1 c/o contact,
1 x 2 c/o contacts
2 x 1 c/o (SPDT) contact iIf operating principle 2 x 1 c/o contact is selected, the output relay R1
(11-12/14) reacts to threshold value t1 and the output relay R2 (21-
22/24) reacts to threshold value t2.
1 x 2 c/o (SPDT) contacts jIf operating principle 1 x 2 c/o contacts is selected, both output relays
R1 (11-12/14) and R2 (21-22/24) react synchronously to one threshold
value.
Overtemperature monitoring: Settings of the threshold value t2 have
no effect on the operation.
Undertemperature monitoring: Settings of the threshold values t2
have no effect on the operation.
Characteristic curves of resistance sensors
-100 0 100 200 300 400 500
5000
4000
3000
2000
1000
0
NTC
KTY83 KTY84 PT1000
PT100
Res
ista
nce
in �
Temperature in °C 2CD
C 2
52 0
76 F
0207
t
t
t
Us
K1
K2
1
2
t
t t
Us
K1
K2
1
2
t
t
t
Us
K 2
K 1
1J
2J
t
t
t
Us
K1
K2
1
2
tt
t
Us
K1
K2
1
2
t
t
Us
-Y1 Y2
K1
tK2
1
2
1S
VC
11
0 0
00
F0
19
1
1S
VC
11
0 0
00
F0
19
2
1S
VC
11
0 0
00
F0
19
5
1S
VC
11
0 0
00
F0
19
6
t
t t
Us
K 2
K 1
1J
2J
1S
VC
11
0 0
00
F0
19
3
1S
VC
11
0 0
00
F0
19
4
1S
VC
11
0 0
00
F0
19
7
Function principle with storage function - C512/C513using overtemperature with closed-circuit principle as an
example
Range monitoring - C512/C513
Overtemperature - C512/C513
Undertemperature - C512/C513
Temperature monitoring relays
Overview, Functional description and diagrams
Functional descriptionDigital tripping devicesOnce the temperature has reached the set threshold of 1,
output relay K1 changes its switching state after the set
time delay t has elapsed (K2 reacts in the same way for 2).
Function diagrams
Open-circuit principle
Open-circuit principle
Open-circuit principle
Closed-circuit principle
Closed-circuit principle
Closed-circuit principle
absolute limit
hysteresis
2/107 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
2-wire measurementWhen using 2-wire temperature sensors the sensor resis-
tance and the wire resistance are added together.
The resulting systematic errors must be taken into account
when adjusting the tripping device.
A jumper must be connected between
the terminals T2 and T3.
The following table can be used for
PT100 sensors to determine the
temperature errors caused by the line
length.
When using resistance sensors with
two-wire connection a bridge must be
inserted between terminals T2 and T3.
Temperature monitoring relays
Connection diagrams, Resistance thermometer sensors
A2
A1
K1 15
1618
K2 25
28
K3 33
34
26
Y2Y1
1T11T21T32T12T22T33T13T23T3
Memory
Ready
1
2
A2
A1
T1
K1 15
16T2T3
18
K2 25
28
K3 33
34
26
Y2Y1
Memory
Ready
1
2
2C
DC
25
2 0
25
F0
01
0
1S
VC
11
0 0
00
F0
20
2
1S
VC
11
0 0
00
F0
20
1
CM-TCS
C512 C513
Connection diagrams
Connection of resistance thermometer sensors
A1-A2 Control supply voltage
11-12/14 Output relay R1
21-22/24 Output relay R2
T1, T2, T3 Measuring input, connection PT100
A1-A2 Rated control suppy
voltage
15-16/18 Output contacts
25-26/28
33-34
T1-T3 Sensor connection
Y1-Y2 Connection for
storage bridge
A1-A2 Rated control suppy
voltage
15-16/18 Output contacts
25-26/28
33-34
1T1-1T3 Sensor connection 1
2T1-2T3 Sensor connection 2
3T1-3T3 Sensor connection 3
Y1-Y2 Connection for
storage bridge
A 1 11 21
T3
24
T2 T1
22
14 12 A2
T1 T2 T3 11 21
A1 A2 12 14 22 24
T2
PT100
T3T1
Temperature error(depending on the line length and conductor cross section
for PT100 sensors at an ambient temperature of 20 °C, in K)
Error caused by the lineThe error resulting from the line resistance amounts to ap-
prox. 2.5 Kelvin/Ohm. If the resistance of the line is not
known and it is not possible to measure it, the error caused
by the line can be estimated using the following table.
3-wire measurementTo minimize the influence of the wire resistance, a three-wire
connection is usually used. By means of the additional wire
two measuring circuits are created.
One of these two circuits is used
for reference. This way, the tripping
device can calculate and take into
account the wire resistance auto-
matically.
Electrical isolation
Line length in m Wire size mm2
0.50 0.75 1 1.5
010255075100200500
0.01.84.59.013.618.136.391.6
0.01.23.06.09.012.124.260.8
0.00.92.34.56.89.018.145.5
0.00.61.53.04.56.012.130.2
12 1411
T1
T2
T3
21
22
24
A1 A224 V AC/DC
2C
DC
25
2 0
19
F0
01
0
12 1411
T1
T2
T3
21
22
24
A1 A224-240 V AC/DC
2C
DC
25
2 0
20
F0
01
0
Electrical isolation
Protective searation acc. to IEC/EN 61140; EN 50178
T2
PT100
T3T1
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/108
2
Temperature monitoring relays
Technical data - CM-TCS.xx
Type CM-TCS.11/12/13 CM-TCS.21/22/23
Input circuitRated control supply voltage U
sA1-A2 24-240 V AC/DC 24 V AC/DC
Rated control supply voltage Us tolerance -15...+10 %
Typical current / power / consumption
24 V DC 33 mA / 0.8 VA 18 mA / 0.45 VA
115 V AC 12.5 mA / 1.5 VA n/a
230 V AC 13 mA / 2.9 VA n/a
Rated frequency AC 15-400 Hz 50/60 Hz
Frequency range AC 13.5-440 Hz 45-65 Hz
Power failure buffering time min. 20 ms
Measuring circuit T1, T2, T3Sensor type PT100
Connection of the sensor 2-wire yes, jumper between T2-T3
3-wire yes, use terminal T1, T2, T3
Monitoring function overtemperature, undertemperature or window monitoring
Threshold values adjustable within the measuring range
CM-TCS.x1 -50…+50 °C
CM-TCS.x2 0…+100 °C
CM-TCS.x3 0…+200 °C
Number of possible thresholds 2
Tolerance of the adjusted threshold value typ. ±5 % of the range end value
Hysteresis related to the threshold value 2-20 % of threshold value, min. 1 °C
Measuring principle continuous current
Typical current in the sensor circuit 0.8 mA
Maximum current in sensor circuit 0.9 mA
Interrupted wire detection yes, indicated via LED status
Short-circuit detection yes, indicated via LED status
Accuracy within the rated control supply voltage tolerance < 0.2 °C / or < 0.01 %/K
Accuracy within the temperature range < 0.2 °C / or < 0.01 %/K
Repeat accuracy (constant parameters) < 0.2 % of full scale
Maximum measuring cycle 320 ms
Output circuitKind of output 2 x 1 or 1 x 2 c/o (SPDT) contacts configurable
Operating principle open- or closed-circuit principle configurable 1)
Contact material AgNi alloy, Cd free
Rated operational voltage (IEC/EN 60947-1) 250 V AC / 300 V DC
Minimum switching voltage / Minimum switching current 24 V / 10 mA
Maximum switching voltage / Maximum switching current see ‘Load limit curves'
Rated operating current Ie
(IEC/EN 60947-1-5)AC-12 (resistive) 230 V 4 A
AC-15 (inductive 230 V 3 A
DC-12 (resistive) 24 V 4 A
DC-13 (inductive) 24 V 2 A
AC Rating (UL508) utilization category B 300, pilot duty general purpose (250 V, 4 A, cos 0.75)
maximum rated operational voltage 250 V AC
maximum continuous thermal current at B 300 4 A
maximum making/breaking apparent power at B 300
3600/360 VA
Mechanical lifetime 30 x 106 switching cycles
Electrical lifetime (AC-12, 230 V, 4 A) 0.1 x 106 switching cycles
Maximum fuse rating to achieve short-circuit protection
n/c contact 6 A fast-acting
n/o contact 10 A fast-acting
Conventional thermal current Ith acc. IEC/EN 60947-1 4 A
General dataDimensions (W x H x D) 22.5 x 85.6 x 103.7 mm (0.89 x 3.37 x 4.08 in)
Mounting position anyScrew connection technology Easy Connect Technology (push-in)
Weight net weight CM-TCS.1x 0.151 kg (0.333 lb) 0.140 kg (0.309 lb)
CM-TCS.2x 0.138 kg (0.304 lb) 0.127 kg (0.280 lb)
gross weight CM-TCS.1x 0.176 kg (0.388 lb) 0.165 kg (0.364 lb)
CM-TCS.2x 0.163 kg (0.360 lb) 0.152 kg (0.335 lb)
Degree of protection enclosure / terminals
IP50 / IP20
Ambient temperature range operation -40...+60 °C
storage/transport -40...+85 °C
Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool
1) Closed-circuit principle: Output relay(s) de-energize(s) if measured value exceeds or falls below the adjusted threshold value
2/109 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Temperature monitoring relays
Technical data - CM-TCS.xx
Type CM-TCS.11/12/13 CM-TCS.21/22/23
Electrical connectionWire size Screw connection technology Easy Connect Technology (Push-in)
fine-strand without wire end ferrule
A1, A2, 11, 12, 14, 21, 22, 24
1 x 0.5-2.5 mm² (1 x 20-14 AWG)2 x 0.5-1.5 mm² (2 x 20-16 AWG)
2 x 0.5-1.5 mm² (2 x 20-16 AWG)connection with lever
T1, T2, T3 1 x 0.2-2.5 mm² (1 x 24-14 AWG)2 x 0.2-1.5 mm² (2 x 24-16 AWG)
2 x 0.2-1.5 mm² (2 x 24-16 AWG)connection with lever
fine-strand with wire end ferrule
A1, A2, 11, 12, 14, 21, 22, 24
1 x 0.5-2.5 mm² (1 x 20-14 AWG)2 x 0.5-1.5 mm² (2 x 20-16 AWG)
2 x 0.5-1.5 mm² (2 x 20-16 AWG)connection: push-in
T1, T2, T3 1 x 0.2-2.5 mm² (1 x 24-14 AWG)2 x 0.2-1.5 mm² (2 x 24-16 AWG)
2 x 0.2-1.5 mm² (2 x 24-16 AWG)insulated ferrule (DIN 46228-4-E):connection: push-inferrule (DIN 46228-1-A):< 0.5 mm², connection with lever� 0.5 mm², connection: push-in
rigid A1, A2, 11, 12, 14, 21, 22, 24
1 x 0.5-4 mm² (1 x 20-12 AWG)2 x 0.5-2.5 mm² (2 x 20-14 AWG)
2 x 0.5-1.5 mm² (2 x 20-16 AWG)connection: push-in
T1, T2, T3 1 x 0.2-4 mm² (1 x 24-12 AWG)2 x 0.2-2.5 mm² (2 x 24-14 AWG)
2 x 0.2-1.5 mm² (2 x 24-16 AWG)< 0.5 mm², connection with lever� 0.5 mm², connection: push-in
Stripping length 8 mm (0.32 in)Tightening torque < 0.5 mm² 0.5 Nm (4.43 lb.in) -
� 0.5 mm² 0.6 - 0.8 Nm (5.31 - 7.08 lb.in) -
StandardsProduct standard IEC/EN 60255-1, IEC/EN 60255-27, EN 50178
Low Voltage Directive 2006/95/EC
EMC Directive 2004/108/EC
RoHS Directive 2011/65/EC
Environmental dataAmbient temperature ranges operation/storage/ transport -40...+60°C/-40...+85°C/-40...+85°C
Climatic category 3K5 (no condensation, no ice formation)
Damp heat, cyclic 6 x 24 h cycle, 55 °C, 95 % RH
Vibration, sinusoidal Class 2
Shock Class 2
Isolation dataRated impulse withstand voltage
Uimp
between all isolated circuits
(IEC/EN 60947-1, IEC/EN 60664-1)
supply circuit / measuring circuit 4 kV -
supply circuit / output circuits 4 kV
measuring circuit / output circuits 4 kV
output circuit 1 / output circuit 2 4 kV
Pollution degree (IEC/EN 60664-1) 3
Overvoltage category (IEC/EN 60664-1) III
Rated insulation voltage Ui
(IEC/EN 60947-1, IEC/EN 60664-1)supply circuit / measuring circuit 300 V -
supply circuit / output circuits 300 V
measuring circuit / output circuits 300 V
output circuit 1 / output circuit 2 300 V
Basis isolation for rated control supply voltage (IEC/EN 60664-1)
supply circuit / measuring circuit 250 V AC / 300 V DC -
supply circuit / output circuits 250 V AC / 300 V DC
measuring circuit / output circuits 250 V AC / 300 V DC
output circuit 1 / output circuit 2 250 V AC / 300 V DC
Protective separation (IEC/EN 61140, EN 50178)
supply circuit / measuring circuit 250 V AC / 250 V DC -
supply circuit / output circuits 250 V AC / 300 V DC 250 V AC / 250 V DC
measuring circuit / output circuits 250 V AC / 300 V DC 250 V AC / 250 V DC
Test voltage between all isolated circuits, routine test (IEC/EN 60255-5, IEC/EN 61010-1)
supply circuit / measuring circuit 2.0 kV, 50 Hz, 1 s -
supply circuit / output circuits 2.0 kV, 50 Hz, 1 s
measuring circuit / output circuits 2.0 kV, 50 Hz, 1 s
Test voltage between all isolated circuits, type test (IEC/EN 60255-5)
supply circuit / measuring circuit 4.0 kV, 50 Hz, 1 s -
supply circuit / output circuits 4.0 kV, 50 Hz, 1 s
measuring circuit / output circuits 4.0 kV, 50 Hz, 1 s
Electromagnetic compatibilityInterference immunity to IEC/EN 61000-6-1, IEC/EN 61000-6-2, IEC/EN 61326-2-4
electrostatic discharge IEC/EN 61000-4-2 Level 3, 6 kV / 8 kV
radiated, radio-frequency, electromagnetic field
IEC/EN 61000-4-3 Level 3, 10 V/m (1 GHz) / 3 V/m (2 GHz) / 1 V/m (2.7 GHz)
electrical fast transient/burst IEC/EN 61000-4-4 Level 3, 2 KV / 5 kHz
surge IEC/EN 61000-4-5 Level 3, installation class 3, supply circuit and measuring circuit 1 kV L-L, 2 kV L-earth
conducted disturbances, induced by radio-frequency fields
IEC/EN 61000-4-6 Level 3, 10 V
voltage dips, short interruptions and voltage variations
IEC/EN 61000-4-11 Class 3
harmonics and interharmonics IEC/EN 61000-4-13 Class 3
Interference emission EN 61000-6-3, EN 61000-6-4
high-frequency radiated IEC/CISPR 22, EN 55022 Class B
high-frequency conducted IEC/CISPR 22, EN 55022 Class B
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/110
2
Temperature monitoring relays
Technical data - C51x
Type C512 C513
Input circuitRated control supply voltage U
sA1-A2 24 V AC/DC -A1-A2 24-240 V AC/DC
Power consumption
AC < 7 VADC < 4 W
Rated control supply voltage US tolerance -15...+10 %
Rated frequency AC
Sensor circuitSensor type PT100, PT1000, KTY83, KTY84, NTCSensor current PT100 typ. 1 mA
PT1000, KTY83, KTY84, NTC typ. 0.2 mAWire-break detection yes (not for NTC)Short-circuit detection yes3-wire connection yes (2-wire connection of sensors with terminals T2 and T3 bridged)
Measuring circuit
Setting accuracy at Ta = 20 °C (T
20) < ±2 K ± 1 digit
Accuracy within the temperature range 0.05 °C / °C deviation from T20
Response time 500 msHysteresis settings temperature 1 1-99 kelvin
temperature 2 1-99 kelvinTripping delay 0-999 s
Output circuitKind of output 2 c/o + 1n/o 2 c/o + 1 n/o
Rated operating current Ie (IEC/EN 60947-1-5) AC-12 (resistive) 230 V n/a
AC-15 (inductive) 230 V 3 A
DC-12 (resistive) 24 V 1 A
DC-13 (inductive) 24 V 0.1 A
Mechanical lifetime 30 x 106 switching cycles
Electrical lifetime (AC-15 at 3 A) 0.1 x 105 switching cycles
Max. fuse rating to achieve short-circuit protection 4 A, operating class gL/gG
General dataDimensions (W x H x D) 45 x 105.9 x 86 mm (1.77 x 4.17 x 3.39 in)
Tightening torque 0.8-1.2 Nm
Mounting position any
Degree of protection enclosure / terminals IP 40 / IP 20
Ambient temperature range operation -25...+60 °C
storage -40...+80 °C
Mounting DIN rail (IEC/EN 60715)
Electrical connectionWire size rigid 1 x 4 mm² (1 x 12 AWG), 2 x 2.5 mm² (2 x 14 AWG)
fine-strand with wire end ferrule 1 x 2.5 mm² (1 x 14 AWG), 2 x 1.5 mm² (2 x 16 AWG)
StandardsEnvironmental conditions IEC 60721-3-3
Low Voltage Directive IEC 60947-5-1, VDE 0660
Electromagnetic compatibility Interference immunity EN 61000-6-2
Interferenece emission EN 61000-6-4
Vibration resistance (IEC 68-2-6) 5-26 Hz / 0.75 mm
Shock resistance (IEC 68-2-27) 15 g / 11 ms
Isolation dataRated insulation voltage 300 V AC
Pollution degree 3
2/111 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Liquid level monitors and controls
Product group picture
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/112
2
Liquid level monitors and controls
Table of contents
Liquid level monitors and controls
Benefits and advantages 2/111
Operating controls 2/112
Ordering details 2/113
Ordering details - Accessories 2/114
Function diagrams 2/115
Connection diagrams 2/117
Application examples 2/118
Technical data 2/120
2/113 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Liquid level monitors and controls
Benefits and advantages
– Monitoring of pump systems for dry running (ENE MIN) and overflow (ENE MAX)
– Connection of 2 electrodes possible at C and MIN/MAX
– 3 supply voltage versions
– Optimal price/performance ratio
– 1 n/o contact: Open-circuit principle for CM-ENE MIN, Closed-circuit principle for CM-ENE MAX
– LED for status indication
– Monitoring and control of liquid levels (when draining or filling liquids in tanks)
– Monitoring and control of mixture ratios (conductivity of liquids)
– Adjustable response sensitivity 5-100 k� – 4 supply voltage versions 24-240 V AC
– Version with protective separation acc. to VDE 0160 J – Cascadable
– 1 c/o contact or 1 n/o and 1 n/c contact
– 2 LEDs for status indication
– Monitoring and control of liquid levels
– Selectable function "fill" or "drain"
– Adjustable response sensitivity 5-100 k� – Cascadable
– 1 c/o contact
– 2 LEDs for status indication
– Monitoring and control of liquid levels (when emptying or filling liquids in tanks)
– Monitoring and control of mixture ratios (conductivity of liquids)
– 3 response sensitivities from 250 � - 500 k� in one unit
– 5 supply voltage versions 24 V AC/DC - 415 V AC
– Selectable ON- or OFF-delay 0.1-10 s
– 2 c/o contacts
– 2 LEDs for status indication
CM-ENE MIN/MAX
CM-ENN
CM-ENS
CM-ENS UP/DOWN
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/114
2
Liquid level monitors and controls
Operating controls
4
1
1
2
2
3
3
CM-ENS
CM-ENN
1 „Sens.“ - sensitivity potentiometer for adjusting the response sensitivity
2 Indication of operational states R: yellow LED - relay status
U: green LED -control supply voltage
3 Marker label
1 „Function.“ - function selector switch: „UP“- fill
„DOWN“ - drain
2 „Sens.“ - potentiometer for adjusting the response sensitivity
3 Indication of operational states R: MIN/MAX: yellow LED - relay status MIN/MAX
U: green LED - control supply voltage
R AL1: yellow LED - relay status AL1
R AL2: yellow LED - relay status AL2
4 Marker label
2C
DC
25
3 0
26
F0
01
32
CD
C 2
53
01
2 F
00
13
2/115 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Liquid level monitors and controls
Ordering details
Description
ABB‘s liquid level monitoring relays for regulation and control of liquid levels and ratios of mix-
tures of conductive fluids.
The assortment includes single function and multifunction monitoring relays which can be
used for overflow and dry-running protection, for filling and draining applications, for max and
min alarm or any combination of such functions. Furthermore a wide range of accessories is
available
Ordering detailsRated control supply voltage Type Order code Price
1 pce
Weight(1 pce) kg (lb)
24 V AC
CM-ENE MIN
1SVR550855R9500 0.15 (0.33)
110-130 V AC 1SVR550850R9500 0.15 (0.33)
220-240 V AC 1SVR550851R9500 0.15 (0.33)
24 V AC
CM-ENE MAX
1SVR550855R9400 0.15 (0.33)
110-130 V AC 1SVR550850R9400 0.15 (0.33)
220-240 V AC 1SVR550851R9400 0.15 (0.33)
24 V AC
CM-ENS
1SVR430851R9100 0.15 (0.33)
110-130 V AC 1SVR430851R0100 0.15 (0.33)
220-240 V AC 1SVR430851R1100 0.15 (0.33)
220-240 V AC 1) 1SVR430851R1300 0.15 (0.33)
24 V AC
CM-ENS UP/DOWN
1SVR430851R9200 0.15 (0.33)
110-130 V AC 1SVR430851R0200 0.15 (0.33)
220-240 V AC 1SVR430851R1200 0.15 (0.33)
24-240 V AC/DC
CM-ENN
1SVR450055R0000 0.30 (0.66)
24 V AC 1SVR450059R0000 0.30 (0.66)
110-130 V AC 1SVR450050R0000 0.30 (0.66)
220-240 V AC 1SVR450051R0000 0.30 (0.66)
1S
VR
55
0 8
51
F9
50
01
SV
R5
50
85
1 F
94
00
1S
VR
43
0 8
51
F1
10
0
1S
VR
45
0 0
55
F0
00
0
CM-ENE MIN
CM-ENE MAX
CM-ENS
CM-ENN
1) Version with protective separation acc. to VDE 0160, 1 n/o, 1 n/c
Suitable for Not suitable forspring water acids, bases chemically pure water ethylene glycol
drinking water liquid fertilizers fuel concentrated alcohol
sea water milk, beer, coffee oils paraffin
sewage non-concentrated alcohol
explosive areas (liquid gas)
lacquers
Liquid level monitors are
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/116
2
Liquid level monitors and controls
Ordering details - Accessories
127
6.80.2681
SV
C 1
10
00
0 F
04
78
1S
VR
45
0 0
56
F6
00
0
Compact support CM-KH-3 for 3 bar electrodes
Suspension electrode CM-HE
– Ideally suited for use with liquid level relays CM-ENS and CM-ENN
– Wire connection by screw terminals
– Pull relief by M16 screwed cable glands
– Temperature range up to 90 °C
– Food safe material (PPH)
– Screw-in electrodes (M4 thread)
– Distance plate (CM-AH-3) and locking nut (CM-GM-1) optionally
available as an accessory
Technical data compact support
Screw-in bar electrodes for compact support CM-KH-3
Description Type Order code Price Pkg qty
Weight (1 pce) kg (lb)
Compact support for 3 bar electrodes CM-KH-3 1SVR450056R6000
1
0.06 (0.132)
Distance plate for 3 bar electrodes CM-AH-3 1SVR450056R7000 0.06 (0.132)
Counter nut for 1“ thread CM-GM-1 1SVR450056R8000 0.06 (0.132)
Lenght Type Order code Price Pkg qty
Weight (1 pce) kg (lb)
300 mm CM-SE-300 1SVR450056R0000
1
0.08 (0.176)
600 mm CM-SE-600 1SVR450056R0100 0.08 (0.176)
1000 mm CM-SE-1000 1SVR450056R0200 0.08 (0.176)
CM-HE CM-HE 1SVR402902R0000 0.08 (0.176)
1S
VC
11
0 0
00
F 0
47
7
spanner size 36
electrodes
distance plate CM-AH-3
counter nut CM-GM-1
M4 thread
1S
VC
11
0 0
00
F 0
47
6
1S
VC
11
0 0
00
F 0
47
5
1" thread
sealing ring
1" counter nut CM-GM-1 (order code: 1SVR 450 056 R8000)
(optional)
distance plate CM-AH-3 (order code: 1SVR 4 450 056 R7000)
(optional)
M16 screwed cable gland
screw-in bar electrodes with M4 thread
(available as an option, see below)
Type of mounting: G 1" thread
Mounting position: any
Enclosure material: PPH
Sealing: NBR 70
Temperature range: 90 °C max.
Pressure: 10 bar max. (60 °C)
1S
VC
11
0 0
00
F 0
47
9
Steel electrode (X14CrMoS17) with
sleeve (Hostalen GC 7260) suitable up
to 60°C max.
Thread M4
Material: stainless steel 304, high-grade
steel 14301
During project engineering the compatibility of the electrode material with the medium to be supervised is to be examined!
2/117 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Liquid level monitors and controls
Function diagrams
Function diagram - CM-ENS UP/DOWN
The CM-ENS monitors levels of conductive liquids and is used for example for liquid level control in pump systems. It can be used for filling or draining tanks for
example. It is also suitable for monitoring the conductivity of liquids. The measuring principle is based on the resistance change sensed by single-pole electrodes.
After the supply voltage is applied to the terminals A1 and A2, the output relay is de-energized. The probes must be connected to C, MAX, MIN. The output relay
energizes if the liquid exceeds the maximum level (C and MAX wet) and de-energizes if the liquid level is below the minimum level (MAX and MIN dry). Basedau m
on the measuring circuit there will be a response delay of approx. 250 ms at maximum sensitivity. Different levels in one tank can be controlled by up to 5 CM-ENS
without interfering with each other.
Function diagram - CM-ENS
The CM-ENS UP/DOWN monitors levels of conductive liquids and other media, and is used e.g. for liquid level control in pump systems.
The measuring principle is based on the resistance change sensed by single-pole electrodes. The output relay functions fill (UP) or drain (DOWN) can be selected
on a front-face selector switch. If the "UP" function is selected, the output relay is energized until the MAX electrode becomes wet. Then it is de-energized and
not re-energized until the MIN electrode becomes dry. If the "DOWN" function is selected, the output relay is energized as soon as the MAX electrode becomes
wet. It remains energized until the liquid level has dropped below the MIN electrode. The electrodes can be connected to more than one CM-ENS unit without
interference.
1S
VC
11
0 0
00
F 0
15
5
Max.
Min.
C
11-14
11-12
A1-A2
1S
VC
11
0 0
00
F 0
16
4
"DOWN"
"UP"
11-14
11-12
Max.
Min.
C
11-14
11-12
A1-A2
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/118
2
Liquid level monitors and controls
Function diagrams
Function diagram - CM-ENE MIN
A1-A2
13-14
MIN
C
Function diagram CM-ENE MAX
A1-A2
13-14
MIN
C
Circuit with 2 electrodes
Circuit with 3 electrodes
Function diagrams - CM-ENN
The liquid level relays CM-ENE MIN and CM-ENE MAX are used to monitor
levels of conductive liquids, for example in pump control systems for dry-
running or overflow monitoring.
The measuring principle is based on the occurring resistance change when
moisting single-pole electrodes. The single-pole electrodes (see also section
Accessories) are connected to the terminals C and MIN or MAX.
If the supply voltage is applied to A1-A2 and the electrodes are wet, the output
relay of the CM-ENE MIN is energized and the output relay of the CM-ENE MAX
is de-energized.
The output relay of the CM-ENE MIN de-energizes if the electrodes are no
longer wet. The output relay of the CM-ENE MAX energizes if the electrodes are
no longer wet.
The CM-ENN monitors levels of conductive liquids and is used for example
for liquid level monitoring in pump control systems, for dry-running protection
of submersible pumps or overflow monitoring of tanks. It is also suitable for
conductivity monitoring of liquids. The measuring principle is based on the
resistance change sensed by single-pole electrodes (wet or dry).
Instead of electrodes, other sensors or transducers can also be used if their
output quantities are different resistance values. The measuring, output and
supply circuits are electrically isolated for potential separation and to prevent
electrical interference.
Due to the integrated ON- or OFF-delay, it is possible to set up time-dependent
liquid controls using only two electrodes (C, MAX). Different liquid levels in
one tank can be controlled by up to 5 CM-ENN (AC version) without mutual
interference.
1S
VC
11
0 0
00
F 0
16
71
SV
C 1
10
00
0 F
01
68
MAX
MIN
C
tA = ON-delay, t
R = OFF-delay
15/18
15/16
A1-A2
MAX
MIN
C
15/18
15/16
A1-A2
1S
VC
11
0 0
00
F 0
15
11
SV
C 1
10
00
0 F
01
52
2/119 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Liquid level monitors and controls
Connection diagrams
Connection diagram CM-ENS
1214 A2
C
A1
MAX
11
MIN
MIN 11MAXC
A2A1 12 14
Connection diagram CM-ENS UP/DOWN
Connection diagram CM-ENN
Connection diagram CM-ENE MIN Connection diagram CM-ENE MAX
1S
VC
11
0 0
00
F 0
15
82
CD
C 2
52
04
2 F
00
03
1S
VC
11
0 0
00
F 0
16
9
1S
VC
11
0 0
00
F 0
15
3
1S
VC
11
0 0
00
F 0
15
4
A1-A2 Rated control supply voltage
C Ground reference electrode
MIN Minimum level
13-14 Output contact -open-circuit principle
A1-A2 Rated control supply voltage
C Ground reference electrode
MAX Maximum level
MIN Minimum level
1115
-1216
/1418
Output contact -open-circuit principle
A1-A2 Rated control supply voltage
C Ground reference electrode
MAX Maximum level
MIN Minimum level
11-12/14 Output contacts - open-circuit or closed-circuit principle selectable
A1-A2 Rated control supply voltage
C Ground reference electrode
MAX Maximum level electrode
MIN Minimum level electrode
1115
-1216
/1418
Output contact -open-circuit principle
A1-A2 Rated control supply voltage
C Ground reference electrode
MIN Maximum level
13-14 Output contact -open-circuit principle
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/120
2
Application examples CM-ENE MIN/MAXCM-ENE MIN CM-ENE MAX CM-ENE MIN und CM-ENE MAX
Liquid level monitors and controls
Application examples
Application examples CM-ENSfill drain
Liquid level control - fill - switch position "UP"
Liquid level control - drain - switch position "DOWN"
Application examples CM-ENS UP/DOWN
1S
VC
11
0 0
00
F 0
49
4
1S
VC
11
0 0
00
F 0
49
5
1S
VC
11
0 0
00
F 0
49
6
1S
VC
11
0 0
00
F 0
15
6
1S
VC
11
0 0
00
F 0
15
7
1S
VC
11
0 0
00
F 0
16
1
1S
VC
11
0 0
00
F 0
16
2
2/121 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Liquid level monitors and controls
Application examples
fill drain
Application examples CM-ENN
For commissioning, set both potentiometers (response sensitivity = R value and ON-delay = time value) to the minimum value
(5) and select a suitable resistance range (sector). After all electrodes have been wetted by the liquid being monitored, turn the
sensitivity potentiometer towards maximum value (100) until the relay energizes. If the relay does not energize, select a higher
� value (sector) on the device and proceed as before. Then it has to be checked if the relay de-energizes properly as soon as
the electrodes C and MIN are no longer wet. Liquid levels higher than the maximum level electrode can be obtained by setting
an ON-delay (TA = 0.1...10 s).
Liquid levels lower than the minimum level electrode can be obtained by setting an OFF-delay time (TR = 0.1...10 s), e.g. for
emptying tanks.
1S
VC
11
0 0
00
F 0
16
5
1S
VC
11
0 0
00
F 0
16
6
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/122
2
Liquid level monitors and controls
Technical data
Type CM-ENE MIN CM-ENE MAXSupply circuitRated control supply voltage U
S -
power consumptionA1-A2 24 V AC approx. 1.5 VA
A1-A2 110-130 V AC approx. 1.2 VA
A1-A2 220-240 V AC approx. 1.4 VA
Rated control supply voltage US tolerance -15...+15 %
Rated frequency 50-60 Hz
Duty time 100 %
Measuring circuit MIN-C, MAX-CMonitoring function dry-running protection overflow protection
Response sensitivity 0-100 k�, not adjustableMaximum electrode voltage 30 V AC
Maximum electrode current 1.5 mA
Electrode supply line max. cable capacity 3 nF
max. cable length 30 m
Timing circuitTime delay -
Tripping delay fixed approx. 200 ms
Indication of operational statesOutput relay energized R: yellow LED
Output circuits 13-14Kind of output 1 n/o contact
Operational principle 1) open-circuit principle closed-circuit principle
Contact material AgCdO
Rated operational voltage Ue (IEC/EN 60947-1) 250 V
Mininimum switching voltage / minimum switching current - / -
Maximum switching voltage 250 V
Rated operational current Ie
(IEC/EN 60947-5-1)AC-12 (resistive) 230 V 4 A
AC-15 (inductive) 230 V 3 A
DC-12 (resistive) 24 V 4 A
DC-13 (inductive) 24 V 2 A
AC rating (UL 508) Utilization category (Control Circuit Rating Code) B 300
max. rated operational voltage 300 V AC
max. continuous thermal current at B 300 5 A
max. making/breaking apparent power at B 300 3600/360 VA
Mechanical lifetime 30 x 106 switching cycles
Electrical lifetime (AC-12, 230 V, 4 A) 0.3 x 106 switching cycles
Max. fuse rating to achieve short-circuit protection
n/c contact -
n/o contact 10 A fast-acting
General dataDimensions (W x H x D) 22.5 x 78 x 78.5 mm (0.89 x 3.07 x 3.09 in)
Mounting position any
Degree of protection enclosure / terminals IP50 / IP20
Ambient temperature range operation / storage -20...+60 °C / -40...+85 °C
Mounting DIN rail (IEC/EN 60715)
Electrical connectionWire size fine-strand with wire-end ferrule 2 x 0.75-1.5 mm2 (2 x 18-16 AWG)
fine-strand without wire-end ferrule 2 x 1-1.5 mm2 (2 x 18-16 AWG)
rigid 2 x 0.75-1.5 mm2 (2 x 18-16 AWG)
Stripping length 10 mm (0.39 inch)
Tightening torque 0.6-0.8 Nm
StandardsProduct standard IEC 255-6, EN 60255-6
Low Voltage Directive 2006/95/EC
EMC Directive 2004/108/EC
Electromagnetic compatibility EN 61000-6-2, EN 61000-6-4electrostatic discharge IEC/EN 61000-4-2 Level 3 (6 kV / 8 kV)
radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 Level 3 (10 V/m)
electrical fast transient / burst IEC/EN 61000-4-4 Level 3 (2 kV / 5 kHz)
surge IEC/EN 61000-4-5 Level 4 (2 kV L-L)
conducted disturbances, induced by radio-frequency fields
IEC/EN 61000-4-6 Level 3 (10 V)
Resistance to vibration (IEC 68-2-6) 6 g
Mechanical resistance (IEC 68-2-6) 10 g
Isolation dataRat. insulation volt. betw. supply, meas. & output circuit (VDE 0110, IEC 60947) 250 V
Rated impulse withstand voltage between all isolated circuits (VDE 0110, IEC 664)
4 kV / 1.2-50 μs
Test voltage between all isolated circuits 2.5 kV, 50 Hz, 1 min.
Pollution category (VDE 0110, IEC 664, IEC 255-5) 3 / C
Overvoltage category (VDE 0110, IEC 664, IEC 255-5) III / C
Environmental testing (IEC 68-2-30) 24 h cycle time, 55 °C, 93 % rel., 96 h
1) Open-circuit principle: Output relay energizes if the measured value exceeds/drops below the adjusted threshold.
Closed-circuit principle: Output relay de-energizes if the measured value exceeds/drops below the adjusted threshold.
2/123 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Liquid level monitors and controls
Technical data
Type CM-ENS CM ENS UP/DOWNSupply circuitRated control supply voltage U
S -
power consumptionA1-A2 24 V AC 24 V AC
A1-A2 110-130 V AC approx. 1.5 VA 110-130 V AC approx. 4 VA
A1-A2 220-240 V AC approx. 1.5 VA 220-240 V AC approx. 4 VA
A1-A2 380-415 V AC approx. 1.5 VA
Rated control supply voltage US
tolerance -15...+10 %
Rated frequency 50-60 Hz
Duty time 100 %
Measuring circuit MAX-MIN-CMonitoring function liquid level control
Response sensitivity 5-100 k , adjustable
Maximum electrode voltage 30 V AC
Maximum electrode current 1 mA
Electrode supply line max. cable capacity 10 nF
max. cable length 100 m
Timing circuitTime delay -
Tripping delay approx. 250 ms
Indication of operational statesControl supply voltage U: green LED
Output relay energized R MAX/MIN: yellow LED
Alarm relay AL1 - R AL1: yellow LED
Alarm relay AL2 - R AL2: yellow LED
Output circuits 11-12/14, 21-22, 31-32Kind of output 1 c/o contact, 1 n/o + 1 n/c contact 2)
Operational principle 1) open-circuit principle open- and closed-circuit principle
Contact material AgCdo
Rated operational voltage Ue (IEC/EN 60947-1) 250 V
Minimum switching voltage / minimum switching current - / -
Maximum switching voltage 250 V
Rated operational current Ie (IEC/EN 60947-5-1) AC-12 (resistive) 230 V 4 A
AC-15 (inductive) 230 V 3 A
DC-12 (resistive) 24 V 4 A
DC-13 (inductive) 24 V 2 A
AC rating (UL 508) Utilization category (Control Circuit Rating Code) B 300
max. rated operational voltage 300 V AC
max. continuous thermal current at B 300 5 A
max. making/breaking apparent power at B 300 3600/360 VA
Mechanical lifetime 30 x 106 switching cycles
Electrical lifetime (AC-12, 230 V, 4 A) 0.3 x 106 switching cycles
Max. fuse rating to achieve short-circuit protection n/c / n/o contact 10 A fast-acting / 10 A fast-acting
General dataDimensions (W x H x D) 22.5 x 70 x 100 mm (0.89 x 3.07 x 3.94 in)
Mounting position any
Degree of protection enclosure / terminals IP50 / IP20
Ambient temperature range operation / storage -20...+60 °C / -40...+85 °C
Mounting DIN rail (IEC/EN 60715)
Electrical connectionWire size fine-strand with wire end ferrule 2 x 2.5 mm2 (2 x 14 AWG)
StandardsProduct standard IEC 255-6, EN 60255-6
Low Voltage Directive 2006/95/EC
EMC Directive 2004/108/EC
Electromagnetic compatibility -electrostatic discharge IEC/EN 61000-4-2 Level 3 (6 kV / 8kV)
radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 Level 3 (10 V/m)
electrical fast transient / burst IEC/EN 61000-4-4 Level 3 (2 kV / 5 kHz)
surge IEC/EN 61000-4-5 Level 4 (2 kV L-L)
conducted disturbances, induced by radio-frequency fields
IEC/EN 61000-4-6 Level 3 (10 V)
Resistance to vibration (IEC 68-2-6) 4 g
Mechanical resistance (IEC 68-2-6) 6 g
Isolation dataRated insulation voltage between supply, measuring and output circuit (VDE 0110, IEC 60947)
250 V
Rated impulse withstand voltage between all isolated circuits (VDE0 110, IEC 664)
4 kV / 1.2 - 50 μs
Test voltage between all isolated circuits 2,5 kV, 50 Hz, 1 min.
Pollution category (VDE 0110, IEC 664, IEC 255-5) 3 / C
Overvoltage category (VDE 0110, IEC 664, IEC 255-5) III / C
Environmental testing (IEC 68-2-30) 24 h cycle time, 55 °C, 93 % rel., 96 h
1) Open-circuit principle: Output relay energizes if the measured value exceeds/drops below the adjusted threshold.
Closed-circuit principle: Output relay de-energizes if the measured value exceeds/drops below the adjusted threshold.2) 1SVR 430 851 R1300 (version with safe isolation)
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/124
2
Type CM-ENNSupply circuitRated control supply voltage U
S - power
consumptionA1-A2 24 V ACA1-A2 110-130 V AC approx. 2.5 VAA1-A2 220-240 V AC approx. 3 VAA1-A2 24-240 V AC/DC approx. 2 VA/W
Rated control supply voltage US
tolerance -15...+10 %
Rated frequency 50-60 Hz oder DCDuty time 100 %Measuring circuit MAX-MIN-CMonitoring function liquid level controlResponse sensitivity adjustable
250 � - 5 k� 2.5-50 k� 25-500 k�Maximum electrode voltage 20 V ACMaximum electrode current 8 mA 2 mA 0.5 mAElectrode supply line max. cable capacity 200 nF 20 nF 4 nF
max. cable length 1000 m 100 m 20 mTiming circuitTime delay 0.1-10 s, adjustable, ON- or OFF-delayIndication of operational statesControl supply voltage U: green LEDOutput relay energized R: yellow LEDOutput circuits 15-16/18, 25-26/28Kind of output 2 c/o contactsOperational principle 1) closed-circuit principleContact material AgCdORated operational voltage U
e IEC/EN 60947-1 400 V
Minimum switching voltage / minimum switching current - / -Maximum switching voltage 400 VRated operational current I
e (IEC/EN 60947-
5-1)AC-12 (resistive) 230 V 5 A
AC-15 (inductive) 230 V 3 ADC-12 (resistive) 24 V 5 A
DC-13 (inductive) 24 V 2.5 AAC rating (UL 508) Utilization category (Control Circuit Rating Code) B 300
max. rated operational voltage 300 V ACmax. continuous thermal current at B 300 5 A
max. making/breaking apparent power at B 300 3600/360 VAMechanical lifetime 30 x 106 switching cyclesElectrical lifetime (AC-12, 230 V, 4 A) 0.1 x 106 switching cyclesMax. fuse rating to achieve short-circuit protection
n/c / n/o contact 4 A fast-acting / 6 A fast-acting
General dataDiemensions (W X H X D) 45 x 78 x 100 mm (1.77 x 3.07 x 3.94 in)Mounting position anyDegree of protection enclosure / terminals IP50 / IP20Ambient temperature range operation / storage -25...+65 °C / -40...+85 °CMounting DIN rail (IEC/EN 60715)Electrical connectionWire size fine-strand with wire end ferrule 2 x 2.5 mm2 (2 x 14 AWG)StandardsProduct standard IEC 255-6, EN 60255-6Low Voltage Directive 2006/95/ECEMC Directive 2004/108/ECElectromagnetic compatibility -electrostatic discharge IEC/EN 61000-4-2 Level 3 (6 kV / 8kV)radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 Level 3 (10 V/m)electrical fast transient / burst IEC/EN 61000-4-4 Level 3 (2 kV / 5 kHz)surge IEC/EN 61000-4-5 Level 4 (2 kV L-L)conducted disturbances, induced by radio-frequency fields
IEC/EN 61000-4-6 Level 3 (10 V)
Resistance to vibration (IEC 68-2-6) 5 gMechanical resistance (IEC 68-2-6) 10 gIsolation dataRated insulation voltage between supply, measuring and output circuit (VDE 0110, IEC 60947)
500 V
Rated impulse withstand voltage between all isolated circuits (VDE 0110, IEC 664) 4 kV / 1.2 - 50 μsTest voltage between all isolated circuits 2,5 kV, 50 Hz, 1 min.Pollution category (VDE 0110, IEC 664, IEC 255-5) 3 / COvervoltage category (VDE 0110, IEC 664, IEC 255-5) III / CEnvironmental testing (IEC 68-2-30) 24 h cycle time, 55 °C, 93 % rel., 96 h
1) Open-circuit principle: Output relay energizes if the measured value exceeds/drops below the adjusted threshold.
Closed-circuit principle: Output relay de-energizes if the measured value exceeds/drops below the adjusted threshold.
Liquid level monitors and controls
Technical data
2
2/125 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
General technical data, Accessories, Current transformers
Notes
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/126
2
General technical data, Accessories, Current transformers
Table of contents
General technical data, Accessories, Current transformers
Technical diagrams - CM-range 2/125
Dimensional drawings 2/127
Ordering details - CM-range accessories 2/128
2/127 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
DC load (resistive)AC load (resistive)
Contact lifetimeDerating factor F for inductive AC load
DC load (resistive)AC load (resistive)CM-N (45 mm)
Load limit curves
CM-S (22.5 mm), CM-E (22.5 mm), CM-UFD.M22
Contact lifetimeDerating factor F for inductive AC load
cos ϕ
F
2CD
C 2
52 1
92 F
0205
0.5
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
0.6
0.7
0.8
0.9
1.0
300
200
100 80 60 50 40 30
20
10 1 2 4 6 10
I A
V
2CD
C 2
52 1
93 F
0205
V
0.1 0.2 0.5
300
200
100 80 60 50 40 30
20
10 1 2 4 6 10
I A
V
2CD
C 2
52 1
94 F
0205
V
0.1 0.2 0.5
cos ϕ
F
2CD
C 2
52 1
92 F
0205
0.5
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
0.6
0.7
0.8
0.9
1.0
1 2 4 6 10
10
20
30
405060
80100
200
300
400
AC current [A]
resistive load
AC
voltage [V
]
2C
DC
252 1
57 F
0206
0.1 0.2 0.5
4321
105
104
106
5 6 7 8
2C
DC
252 1
56 F
0206
Switching current [A]
Sw
itchin
g c
ycle
s
250 V AC
resistive load
Switching current [A]
250 V
resistive load
Sw
itchin
g c
ycle
s
2C
DC
252 1
48 F
0206
1 2 4 6 10
10
20
30
405060
80100
200
300
400
0.1 0.2 0.5
AC current [A]
resistive load
AC
voltage [V
]
2C
DC
252 1
58 F
0206
General technical data, Accessories, Current transformers
Technical diagrams - CM-range
2C
DC
25
2 1
94
F0
20
5
2C
DC
25
2 1
93
F0
20
52
CD
C 2
52
14
8 F
02
06
2C
DC
25
2 1
58
F0
20
6
2C
DC
25
2 1
92
F0
20
52
CD
C 2
52
15
7 F
02
06
2C
DC
25
2 1
92
F0
20
5
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/128
2
General technical data, Accessories, Current transformers
Technical diagrams - CM-range
Load limit curves CM-UFD.M21
300
200
100 80 60 50 40 30
20
10 1 2 4 6 10
I A
V
U
0.1 0.2 0.5
resistive load
2C
DC
25
2 0
10
F0
21
2
AC load (resistive)
300
200
100 80 60 50 40 30
20
10 1 2 5 10
I A
V
U
0.1 0.2 0.5
resistive load
2C
DC
25
2 0
11
F0
21
2
DC load (resistive)
104
2 4 6 8 10 12 14 16
105
106
107
Switching current [A]
250 V AC
resistive load
Sw
itchin
g c
ycle
s
2C
DC
25
2 0
12
F0
21
2
Contact lifetime
2/129 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
Dimensional drawing CM-UFD.Mxx
2C
DC
25
2 0
08
F0
01
3
90
3.54
”
108 4.25”67 2.64”
General technical data, Accessories, Current transformers
Dimensional drawings
0.039
1S
VC
11
0 0
00
F 0
17
7
C512C513
� 5 ... 6 mm / PZ20,8 ... 1,2 Nm7 ... 10.3 lb·in
1 x 0,5 ... 4,0 mm²2 x 0,5 ... 2,5 mm²
2 x 0,5 ... 1,5 mm²1 x 0,5 ... 2,5 mm²
—
AWG 2 x 20 ... 14
10
10
10
a b c d
C512, C513 65 36 82,6 105,9
6
b
a
86
28,8
c d
201
6
45
7,2
2,86
5,19
73x5,811
73x5,831
2C
DC
25
2 2
88
F0
00
5
1S
VC
11
0 0
00
F0
42
3
CM-S22.5 mm
CM-N45 mm
CM-E 22.5 mm
Measuring and monitoring relays CM range old housing
Measuring and monitoring relays CM range new housing
C512/C513 45 mm
CM-xxN 1SVR 750 xxx xxx, 1SVR 760 xxx xxx 45 mm
CM-xxS 1SVR 730 xxx xxx, 1SVR 740 xxx xxx 22.5 mm
Dimensions in mm
Temperature monitoring relays
2C
DC
25
2 0
22
F0
01
1
2C
DC
25
2 0
10
F0
01
1
114.5 4.51”
45.0 1.77”
85.6
3
.37”
104.8 4.13”
107.0 4.21”
113.4 44.65”
22.5 0.89”
85.6
3
3.70
”103.7 40.83”
105.9 41.69”
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/130
2
2CD
C 2
52 1
87 F
0005
4,5 62,5
60
1011
,5
22,5
.177
”
2.46”
2.36”
.394
”
.886
”
.453
”
203A11 8
.315
”
.787”
2CD
C 2
52 1
86 F
0005
2CD
C 2
52 1
85 F
000522,5
68,5
73,5
.886”
2.70
”
.138”.275”
front-to-backsize 107
1S
VC
11
0 0
00
F 0
18
0
ADP.01
MAR.01
Sealable cover COV.01
Sealable cover COV.02
Accessories
General technical data, Accessories, Current transformers
Ordering details - CM-range accessories
Ordering detailsDescrip-tion
For type Width in mm
for devices Type Order code Price
pce
Pkg qty
Weight(1 pce)g (oz)
Adapter for screw mounting
CM-SCM-S.S/P
22.5 ADP.01 1SVR430029R0100 1 18.4 (0.65)
CM-NCM-N.S/P
45 ADP.02 1SVR440029R0100 1 36.7 (1.30)
Marker label
CM-S, CM-NCM-S.S/PCM-N.S/P
without DIP switches
MAR.01 1SVR366017R0100 100.19 (0.007)
CM-S, CM-Nwith DIPswitches
MAR.02 1SVR430043R0000 100.13 (0.005)
CM-S.S/PCM-N.S/P
with DIPswitches
MAR.12 1SVR730006R0000 100.152 (0.335)
Sealable transparent cover
CM-S 22.5 COV.01 1SVR430005R0100 1 5.2 (0.18)
CM-N 45 COV.02 1SVR440005R0100 1 7.7 (0.27)
CM-S.S/P 22.5 COV.11 1SVR730005R0100 1 4.0 (0.129)
CM-N.S/P 45 COV.12 1SVR750005R0100 1 7 (0.247)
2/131 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2
General technical data, Accessories, Current transformers
Ordering details - CM-CT current transformers
2C
DC
25
1 0
02
F0
00
52C
DC
25
1 0
03
F0
00
5
CM-CT
k l
K-P1
�26
a
abcde
10,5 mm12,5 mm20,5 mm25,5 mm30,5 mm
0.41 inch0.49 inch0.81 inch1.00 inch1.20 inch
31 1
.22“
6,5
0.2
6“
75,5
2.9
7“78
,5 3
.09“
61 2.36“48 1.89“35 1.38“
a b c d e
bcde
40 1.57“
30 1.18“47 1.85“62 2.40“
60 2.36“
2C
DC
252 1
53 F
0b
06
2C
DC
251 1
59 F
0b
06
CM-CT with mounted accessories
Plug-in current transformers CM-CT – Without primary conductor though with foot angle, insulating protective cap and bar
fastening screws
– Primary / rated current from 50 A to 600 A
– Secondary current of 1 A or 5 A
– Class 1
Operating principle / circuit diagram Dimensional drawing
K/P1 k/S1
l/S2L/P2
load
2C
DC
252 0
01 F
0206
CM-CT-A mounted on DIN rail
Ordering detailsRated primary current
Secondary current
Burden class Type Order code Price
pce
Weight(1 pce)g (oz)
50 A
1 A
1 VA / 1 CM-CT 50/1 1SVR450116R1000 0.31 (0.683)
75 A 1.5 VA / 1 CM-CT 75/1 1SVR450116R1100 0.31 (0.683)
100 A 2.5 VA / 1 CM-CT 100/1 1SVR450116R1200 0.276 (0.608)
150 A 2.5 VA / 1 CM-CT 150/1 1SVR450116R1300 0.32 (0.705)
200 A 2.5 VA / 1 CM-CT 200/1 1SVR450116R1400 0.222 (0.489)
300 A 5 VA / 1 CM-CT 300/1 1SVR450117R1100 0.29 (0.639)
400 A 5 VA / 1 CM-CT 400/1 1SVR450117R1200 0.27 (0.595)
500 A 5 VA / 1 CM-CT 500/1 1SVR450117R1300 0.29 (0.639)
600 A 5 VA / 1 CM-CT 600/1 1SVR450117R1400 0.24 (0.529)
50 A
5 A
1 VA / 1 CM-CT 50/5 1SVR450116R5000 0.3 (0.661)
75 A 1.5 VA / 1 CM-CT 75/5 1SVR450116R5100 0.31 (0.683)
100 A 2.5 VA / 1 CM-CT 100/5 1SVR450116R5200 0.31 (0.683)
150 A 2.5 VA / 1 CM-CT 150/5 1SVR450116R5300 0.28 (0.617)
200 A 5 VA / 1 CM-CT 200/5 1SVR450116R5400 0.29 (0.639)
300 A 5 VA / 1 CM-CT 300/5 1SVR450117R5100 0.252 (0.556)
400 A 5 VA / 1 CM-CT 400/5 1SVR450117R5200 0.26 (0.573)
500 A 5 VA / 1 CM-CT 500/5 1SVR450117R5300 0.208 (0.459)
600 A 5 VA / 1 CM-CT 600/5 1SVR450117R5400 0.21 (0.463)
Ordering details - AccessoriesDescription Type Order code Price
10 pces
Weight(1 pce)g (oz)
Snap-on fastener for DIN rail mounting of CM-CT CM-CT A 1SVR450118R1000 0.009 (0.02)
2
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/132
General technical data, Accessories, Current transformers
Notes
3
3/1 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Primary switch mode power supplies
Product group picture
3
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/2
Primary switch mode power supplies
Table of contents
Primary switch mode power supplies
Overview 3/3
Approvals and marks 3/4
Selection table - Single-phase 3/5
Selection table - Three-phase, CP-ASI 3/6
CP-D range ...................................................................................... 3/7
Benefits and advantages 3/9
Ordering details 3/10
Technical data 3/11
Technical diagrams 3/15
Dimensional drawings 3/16
CP-E range .................................................................................... 3/17
Benefits and advantages 3/19
Ordering details 3/20
Technical data 3/21
Technical diagrams, Wiring instructions 3/29
Technical diagrams, Dimensional drawings 3/30
CP-T range .................................................................................... 3/31
Benefits and advantages 3/33
Ordering details 3/34
Technical data 3/35
Technical diagrams, Dimensional drawings 3/39
Technical diagrams 3/40
CP-S and CP-C .............................................................................. 3/41
Benefits and advantages 3/43
Operating control 3/44
Ordering details 3/45
Technical data 3/46
Technical diagrams, Dimensional drawings 3/50
Redundancy units ........................................................................... 3/51
Ordering details 3/51
Technical data 3/52
Dimensional drawings 3/56
CP-ASI range ................................................................................. 3/57
Benefits and advantages 3/59
Ordering details 3/60
Technical data 3/61
Technical diagrams 3/63
Dimensional drawings 3/64
CP-B range .................................................................................... 3/65
Benefits and advantages 3/67
Ordering details 3/68
Technical data 3/69
Technical data, Technical diagrams 3/70
Dimensional drawings 3/71
Technical data 3/72
Electronic protection devices EPD24 ............................................... 3/73
Ordering details 3/75
Technical data 3/76
Technical information 3/78
Approvals, Safety instructions 3/79
Installation guidelines 3/80
3
3/3 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Primary switch mode power supplies
Overview
Application manualFor today’s applications, e.g. in control engineering, it is es-
sential to make the right decision regarding the selection and
planning of the power supply unit. Incorrect dimensioning or
incorrect connection of a power supply unit can seriously af-
fect the safety and/or availability of the entire installation.
ABB’s “Power Supply Units” application manual provides a
general overview of switch mode power supply units, thus
helping you to choose the ideal power supply unit and avoid
problems during engineering and commissioning. The manual
generally shows and explains the fundamental characteristics
of and the differences between power supply units, and pro-
vides a detailed introduction to the ABB product range on the
basis of the selection criteria. Finally, it describes and explains
application examples for engineering.
CP-DThe CP-D range of power supply units in MDRC design
(modular DIN rail components) fits into all domestic installation
and distribution panels.
CP-EThe CP-E range offers enhanced functionality while the num-
ber of different types has been considerably reduced. Now all
power supply units can be operated at an ambient tempera-
ture of up to +70 °C.
CP-TThe CP-T range of three-phase power supply units is ABB’s
youngest member of the power supply family.
CP-SThe CP-S range is ABB’s standard range, a high-end power
supply unit optimised for serial applications.
CP-CThe CP-C range’s pluggable function modules adapt these
power supply units exactly to your application’s needs. Of
course, all ABB power supply units feature primary switch
mode technology – environmentally sound and cost-efficiency.
This represents the highest level of innovative industrial elec-
tronics.
The manual is available in English and German.
English Version: 2CDC 114 048 M0203
German Version: 2CDC 114 048 M0103
Modern power supply units are a vital component in most areas of energy management and automation technology. ABB as
your global partner in these areas pays the utmost attention to the resulting requirements. Innovation is the key to a substantial
enlargement of our power supply product program:
3
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/4
� existing � pending
CP-D
Approvals CP
-D 1
2/0
.83
CP
-D 1
2/2
.1
CP
-D 2
4/0
.42
CP
-D 2
4/1
.3
CP
-D 2
4/2
.5
CP
-D 2
4/4
.2
CP
-D R
U
AUL 508, CAN/CSA C22.2
No.107.1�1) �1) �1) �1) �1) �1)
H UL 1310, CAN/CSA C22.2 No.223 (Class 2 Power Supply) �1) �1) �1) �1) �1)
H UL 60950, CAN/CSA C22.2 No.60950 �1) �1) �1) �1) �1) �1)
K CB Scheme �1) �1) �1) �1) �1) �1)
R EAC �1) �1) �1) �1) �1) �1)
E CCC �1) �1) �1) �1) �1) �1)
Marks
a CE � � � � � � �b C-Tick � � � � � � �
� existing � pending
CP-E CP-T
Approvals CP
-E 5
/3.0
CP
-E 1
2/2
.5
CP
-E 1
2/1
0.0
CP
-E 2
4/0
.75
CP
-E 2
4/1
.25
CP
-E 2
4/2
.5
CP
-E 2
4/5
.0
CP
-E 2
4/1
0.0
CP
-E 2
4/2
0.0
CP
-E 4
8/0
.62
CP
-E 4
8/1
.25
CP
-E 4
8/5
.0
CP
-E 4
8/1
0.0
CP
-RU
D
CP
-T 2
4/5
.0
CP
-T 2
4/1
0.0
CP
-T 2
4/2
0.0
CP
-T 2
4/4
0.0
CP
-T 4
8/5
.0
CP
-T 4
8/1
0.0
CP
-T 4
8/2
0.0
A UL 508, CAN/CSA C22.2 No.107.1 �1) �1) �1) �1) �1) �1) �1) �1) �1) �1) �1) �1) �1) �1) �1) �1) �1) �1) �1) �1)
H UL 1310, CAN/CSA C22.2 No.223 (Class 2 Power Supply)
� � � � � � �
HANSI/ISA-12.12 (Class I, Div. 2, hazardous locations) CAN/CSA C22.2 No. 213
� � � � � � � � � � � � � � � � � � � �
H UL 60950, CAN/CSA C22.2 No.60950 �1) �1) �1) �1) �1) �1) �1) �1) �1) �1) �1) �1) �1) �1) �1) �1) �1) �1) �1) �1)
R EAC � � � � � � � � � � � � � � � � � � � �
E CCC �1) �1) �1) �1) �1) �1) �1) �1) �1) �1) �1) �1) �1)
GB4943, GB9254, GB17625.1 � � � � � � �
Marks
a CE � � � � � � � � � � � � � � � � � � � � �
b C-Tick � � � � � � � � � � � � � � � � � � � � �
� existing � pending
CP-S CP-C CP-A CP-B
Approvals CP
-S 2
4/5
.0
CP
-S 2
4/1
0.0
CP
-S 2
4/2
0.0
CP
-C 2
4/5
.0
CP
-C 2
4/1
0.0
CP
-C 2
4/2
0.0
CP
-C M
M
CP
-A R
U
CP
-A C
M
CP
-B 2
4/3
.0
CP
-B 2
4/1
0.0
CP
-B 2
4/2
0.0
CP
-B E
XT.2
AUL 508, CAN/CSA C22.2
No.107.1�1) �1) �1) �1) �1) �1) � � � �
A UL 1604 (Class I, Div. 2, hazardous locations), CAN/CSA C22.2 No.213
�1) �1) �1) �1) �1) �1)
H UL 60950, CAN/CSA C22.2 No.60950 �1) �1) �1) �1) �1) �1) �1) �1)
R EAC � � � � � � � � � � � � �
K CB scheme � � � � � � � �
Marks
a CE � � � � � � � � � � � � �
b C-Tick � � � � � � � � �
1) Approvals refer to the rated input voltage Uin.
Primary switch mode power supplies
Approvals and marks
3
3/5 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Ord
er n
um
ber
1S
VR
42
70
41R
10
00
1S
VR
42
70
43
R12
00
1S
VR
42
70
41R
00
00
1S
VR
42
70
43
R0
10
0
1S
VR
42
70
44
R0
20
0
1S
VR
42
70
45
R0
40
0
1S
VR
42
70
33
R3
00
0
1S
VR
42
70
32
R10
00
1S
VR
42
70
35
R10
00
1S
VR
42
70
30
R0
00
0
1S
VR
42
70
31R
00
00
1S
VR
42
70
32
R0
00
0
1S
VR
42
70
34
R0
00
0
1S
VR
42
70
35
R0
00
0
1S
VR
42
70
36
R0
00
0
1S
VR
42
70
30
R2
00
0
1S
VR
42
70
31R
20
00
1S
VR
42
70
34
R0
00
0
1S
VR
42
70
35
R2
00
0
1S
VR
42
70
14
R0
00
0
1S
VR
42
70
15
R0
10
0
1S
VR
42
70
16
R0
10
0
1S
VR
42
70
24
R0
00
0
1S
VR
42
70
25
R0
00
0
1S
VR
42
70
26
R0
00
0
Single phase
CP-D CP-E CP-S CP-C
Rated output voltage 5 V DC �12 V DC � � � �24 V DC � � � � � � � � � � � � � � � �48 V DC � � � �
Rated output current 0.42 A �0.625 A �
0.75 A �0.83 A �1.25 A � �
1.3 A �2.1 A �2.5 A � � �
3 A �4.2 A �
5 A � � � �10 A � � � � �20 A � � �
Rated output power 10 W � �15 W �18 W �30 W � � � � �60 W � � �
100 W �120 W � � � �240 W � � � �480 W � � � �
Rated input voltage
100 - 240 V AC � � � � � � � � � � � � �115/230 V AC auto select � � � �
115 - 230 V AC � �110 - 240 V AC � � � �110 - 120 V AC � �220 - 240 V AC � �
DC input voltage range
120 - 370 V DC � � � � � � � � � �90 - 375 V DC � � � � �
210 - 370 V DC � � � �100 - 350 V DC � � � �220 - 350 V DC � �
Features Power reserve design � � � � � �Adjustable output voltage � � � � � � � � � � � � � � � � � � � �Integrated input fuse � � � � � � � � � � � � � � � � � � � � � � � � �
Short circuit stable � � � � � � � � � � � � � � � � � � � � � � � � �Fold forward behavior (U/I) � � � � � � � � � � � � � � � � � � � � � � �Fold back behavior (hiccup) � �Power factor correction pas pas pas act pas act act act act
Ambient temp. rating -25°C (-40°C) to 70°C
� � � � � � � � � � � � � � � � � � � � � � � � �
Parallel connection � � 3 � � � 3 3 3 � � 3 3 5 5 5 5 5 5
Serial connection � � � � � � � � 2 � � � 2 2 2 � � 2 2 � � � � � �
Primary switch mode power supplies
Selection table - Single-phase
3
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/6
Ord
er n
um
ber
1S
VR
42
70
54
R0
00
0
1S
VR
42
70
55
R0
00
0
1S
VR
42
70
56
R0
00
0
1S
VR
42
70
57
R0
00
0
1S
VR
42
70
54
R2
00
0
1S
VR
42
70
55
R2
00
0
1S
VR
42
70
56
R2
00
0
1S
VR
42
70
90
R0
28
0
1S
VR
42
70
90
R0
40
0
1S
VR
42
70
95
R0
40
0
1S
VR
42
70
90
R0
80
0
Three phase AS-Interface
CP-T CP-ASI
Rated output voltage 24 V DC � � � �30.5 V DC � � � �
48 V DC � � �
Rated output current 2.8 A �3 A � �5 A � �8 A �
10 A � �20 A � �40 A �
Rated output power 85 W �120 W �122 W � �240 W � �244 W �480 W � �960 W � �
Rated input voltage
85-132 V AC, 184-264 V AC � � �
3 x 400 - 800 V AC � � � � � � �
DC inputvoltage range
18-32.4 V DC �
480 - 820 V DC � � � � � � �
Features Adjustable output voltage � � � � � � �Integrated input fuse � � � � � � �
Short circuit stable � � � � � � �Fold forward behavior (U/I) � � � � �Fold back behavior (hiccup) � � � � � � �
Power factor correction
Ambient temp. rating -25°C (-40°C) to 70°C
� � � � � � �
Serial connection 2 2 2 2 2 2
Suited for AS-Interfaces � � � �
Primary switch mode power supplies
Selection table - Three-phase, CP-ASI
3
3/7 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
CP-D range
Product group picture
3
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/8
CP-D range
Table of contents
CP-D range
Product group picture 3/7
Table of contents 3/8
Benefits and advantages 3/9
Ordering details 3/10
Technical data 3/11
Technical diagrams 3/15
Dimensional drawings 3/16
3
3/9 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2C
DC
27
1 0
27
F0
00
7
2C
DC
27
6 0
32
F0
00
7
2C
DC
27
6 0
33
F0
00
7
Characteristics – Output voltages 12 V, 24 V DC
– Adjustable output voltages (devices > 10 W)
– Output currents 0.42 A / 0.83 A / 1.3 A / 2.1 A / 2.5 A / 4.2 A
– Power range 10 W, 30 W, 60 W, 100 W
– Wide range input 100-240 V AC (90-264 V AC, 120-375 V DC)
– High efficiency of up to 89 %
– Low power dissipation and low heating
– Free convection cooling (no forced cooling with ventilators)
– Ambient temperature range during operation -40 °C...+70 °C
– Open-circuit, overload and short-circuit stable
– Integrated input fuse
– U/I characteristic (fold-forward behaviour at overload – no
switch-off)
– LEDs for status indication
– Light-grey housing in RAL 7035
– Approvals / Marks (depending on device, partly pending):
A, H, R, E / a, b
Width and structural formWith their width between 18 to 90 mm only, the CP-D range
switch mode power supplies are ideally suited for installation
in distribution panels.
Wide range inputOptimised for world-wide applications: The CP-D power sup-
plies can be supplied with 90-264 V AC or 120-375 V DC.
Adjustable output voltageThe CP-D range types > 10 W feature a continuously adjust-
able output voltage. Thus, they can be optimally adapted to
the application, e.g. compensating the voltage drop caused
by a long line length.
Benefits
1
1
2
2
3
3
CP-D range
Benefits and advantages
4
1
2
3
5
1 OUTPUT ++/--: terminals - output
2 INPUT L, N: terminals - input
3 Indication of operational states DC ON: green LED - output voltage applied
DC LOW: red LED - output voltage too low
4 Circuit diagram
5 OUTPUT Adjust: potentiometer - adjustment of output voltage
3
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/10
Description
The CP-D range of modular power supply units in MDRC design (modular DIN rail compo-
nents) is ideally suited for installation in distribution panels. This range offers devices with
output voltages of 12 V DC and 24 V DC at output currents of 0.42 A to 4.2 A. Thanks to a
high thermal efficiency corresponding to low power and heat dissipation, the devices can be
operated without forced cooling. All devices feature the U/I output characteristic (fold forward
behaviour). All power supply units in the CP-D range are approved according to all relevant
international standards.
Ordering detailsInput voltage range Rated
output voltage / current
Type Order code Price
1 pce
Weight(1 pce)kg (lb)
90-264 V AC/ 120-375 V DC 12 V DC / 0.83 A CP-D 12/0.83 1SVR427041R10000.06 (0.13)
90-264 V AC/ 120-375 V DC 12 V DC / 2.1 A CP-D 12/2.1 1SVR427043R12000.19 (0.41)
90-264 V AC/ 120-375 V DC 24 V DC / 0.42 A CP-D 24/0.42 1SVR427041R00000.06 (0.13)
90-264 V AC/ 120-375 V DC 24 V DC / 1.3 A CP-D 24/1.3 1SVR427043R01000.19 (0.41)
90-264 V AC/ 120-375 V DC 24 V DC / 2.5 A CP-D 24/2.5 1SVR427044R02000.25 (0.56)
90-264 V AC/ 120-375 V DC 24 V DC / 4.2 A CP-D 24/4.2 1SVR427045R04000.32 (0.71)
2C
DC
27
1 0
24
F0
00
7
2C
DC
27
1 0
25
F0
00
7
2C
DC
27
1 0
28
F0
00
7
CP-D 12/0.83, CP-D 24/0.42
CP-D 12/2.1, CP-D 24/1.3
CP-D 24/2.5
CP-D range
Ordering details
3
3/11 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Data at Ta = 25 °C, U
in = 230 V AC and rated values, unless otherwise indicated
Type CP-D 12/0.83 CP-D 12/2.1
Input circuit - supply circuit L, NRated input voltage U
in100-240 V AC
Input voltage range 90-264 V AC / 120-375 V DC
Frequency range AC 47-63 Hz
Typical input current / typical power consumption
at 110 V AC 200 mA / 12.68 W 502 mA / 31.14 W
at 230 V AC 128.3 mA / 13.01 W 277 mA / 31.2 W
Inrush current limiting at 230 V AC 30 A (max. 3 ms) 50 A (max. 3 ms)
Power failure buffering time min. 30 ms
Internal input fuse 1 A slow-acting / 250 V AC 2 A slow-acting / 250 V AC
Power factor correction (PFC) no
Indication of operational statesOutput voltage DC ON: green LED V: output voltage applied
DC LOW: red LED V: output voltage too low
Output circuit +, - ++, --Rated output voltage 12 V DC
Tolerance of the output voltage ±1 %
Adjustment range of the output voltage - 12-14 V DC
Rated output power 10 W 25 W
Rated output current Ir
Ta � 60 °C 0.83 A 2.1 A
Derating of the output current 60 °C < Ta � 70 °C 2.5 %/°C
Maximum deviation with
load change statical max. 1 %
change of output voltage within the input voltage range max. 1 %
Control time < 1 ms
Starting time after applying the supply voltage
at Ir
1000 ms
Rise time at rated load typ. 1 ms
Residual ripple and switching peaks BW = 20 MHz 50 mV
Parallel connection yes, using CP-D RU
Series connection yes, to increase voltage
Resistance to reverse feed 18 V / 1 s
Output circuit - No-load, overload and short-circuit behaviourCharacteristic curve of output U/I characteristic curve
Short-circuit protection continuous short-circuit stability
Short-circuit behaviour continuation with output power limiting
Current limiting at short circuit typ. 1.4 A typ. 5.9 A
Overload protection output power limiting
Overvoltage protection 15-16.5 V DC
No-load protection continuous no-load stability
Starting of capacitive loads unlimited
General dataEfficiency typ. 78 % typ. 82 %
Duty time 100 %
Dimensions (W x H x D) 18 x 91 x 57.5 mm (0.71 x 3.58 x 2.26 in)
53 x 91 x 57.5 mm (2.09 x 3.58 x 2.26 in)
Weight 0.066 kg (0.13 lb) 0.196 kg (0.41 lb)
Material of housing plastic
Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool
Mounting position horizontal
Minimum distance to other units horizontal / vertical 25 mm / 25 mm (0.98 in / 0.98 in)
Degree of protection housing / terminals IP20 / IP20
Protection class II
CP-D range
Technical data
3
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/12
Data at Ta = 25 °C, U
in = 230 V AC and rated values, unless otherwise indicated
Type CP-D 12/0.83 CP-D 12/2.1
Electrical connection - Input circuit / Output circuitWire size fine-strand with wire end ferrule 0.2-1.5 mm2 (24-16 AWG) 0.2-2.5 mm2 (24-14 AWG)
rigid 0.2-2.5 mm2 (26-12 AWG) 0.2-2.5 mm2 (24-12 AWG)Stripping length 4-5 mm (0.16-0.2 in) 7 mm (0.28 in)
Tightening torque 0.6 Nm (5 lb.in) 0.7 Nm (6 lb.in)
Environmental dataAmbient temperature range operation -40…+70 °C
rated load -40…+60 °C
storage -40…+85 °C
Damp heat (cyclic) (IEC/EN 60068-2-30) 4 x 24 cycles, 40 °C, 95 % RH
Vibration (sinusoidal) (IEC/EN 60068-2-6) 50 m/s2, 10 Hz - 2 kHz
Shock (half-sine) (IEC/EN 60068-2-27) 40 m/s2, 22 ms
Isolation dataRated insulation voltage U
iinput circuit / output circuit 3 kV AC
Pollution degree 2
Overvoltage category (UL/IEC/EN 60950-1) ll
StandardsProduct standard EN 61204
Low Voltage Directive 2006/95/EC
EMC Direcitve 2004/108/EC
Electrical safety UL 508, UL 60950-1, EN 60950-1
Protective low voltage SELV (EN 60950-1)
Electromagnetic compatibilityInterference immunity to EN 61000-6-2
electrostatic discharge IEC/EN 61000-4-2 Level 4 (4 kV / 8 kV) Level 4 (4 kV / 15 kV)
radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 Level 3 (10 V/m)
electrical fast transient/burst IEC/EN 61000-4-4 Level 4 (4 kV)
surge IEC/EN 61000-4-5 Level 3 (2 kV L-L)
conducted disturbances, induced by radio-frequency fields
IEC/EN 61000-4-6 Level 3 (10 V)
Interference emission EN 61000-6-3
high-frequency radiated IEC/CISPR 22, EN 55022 Class B
high-frequency conducted IEC/CISPR 22, EN 55022 Class B
„Approvals and marks“ on page 3/4.
CP-D range
Technical data
3
3/13 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
CP-D range
Technical data
Data at Ta = 25 °C, U
in = 230 V AC and rated values, unless otherwise indicated
Type CP-D 24/0.42 CP-D 24/1.3 CP-D 24/2.5 CP-D 24/4.2
Input circuit - supply circuit L, NRated input voltage U
in100-240 V AC
Input voltage range 90-264 V AC /120-375 V DC
Frequency range AC 47-63 Hz
Typical input current / typical power consumption
at 110 V AC 184 mA / 11.62 W 600 mA / 37.92 W 1120 mA / 69.3 W 1800 mA / 117.3 W
at 230 V AC 120.6 mA / 12 W 344 mA / 38.16 W 660 mA / 70.1 W 900 mA / 114.4 W
Inrush current limiting at 230 V AC 30 A (max. 3 ms) 50 A (max. 3 ms) 60 A (max. 3 ms)
Power failure buffering time min. 30 ms min. 60 ms
Internal input fuse 1 A slow-acting / 250 V AC
2 A slow-acting / 250 V AC
3.15 A slow-acting / 250 V AC
Power factor correction (PFC) no
Indication of operational statesOutput voltage DC ON: green LED V: output voltage applied
DC LOW: red LED V: output voltage too low
Output circuit +, - ++, --Rated output voltage 24 V DC
Tolerance of the output voltage ±1 %
Adjustment range of the output voltage - 24-28 V DC
Rated output power 10 W 30 W 60 W 100 W
Rated output current Ir
Ta � 60 °C: 0.42 A T
a � 60 °C: 1.3 A T
a � 55 °C: 2.5 A T
a � 60 °C: 4.2 A
Derating of the output current 60 °C < Ta � 70 °C:
2.5 %/°C60 °C < T
a � 70 °C:
2.5 %/°C55 °C < T
a � 70 °C:
2.5 %/°C60 °C < T
a � 70 °C:
2.5 %/°CMaximum deviation with
load change statical max. 1 %
change of output voltage within the input voltage range max. 1 %
Control time < 1 ms
Starting time after applying the supply voltage at Ir
1000 ms
Rise time at rated load typ. 1 ms
Residual ripple and switching peaks BW = 20 MHz 50 mV
Parallel connection yes, using CP-D RU
Series connection yes, to increase voltage
Resistance to reverse feed 35 V / 1 s
Output circuit - No-load, overload and short-circuit behaviourCharacteristic curve of output U/I characteristic curve
Short-circuit protection continuous short-circuit stability
Short-circuit behaviour continuation with output power limiting
Current limiting at short circuit typ. 0.78 A typ. 4.2 A typ. 6.05 A typ. 11.5 A
Overload protection output power limiting
Overvoltage protection 30-33 V DC
No-load protection continuous no-load stability
Starting of capacitive loads unlimited
General dataEfficiency typ. 80 % typ. 83 % typ. 86 % typ. 89 %
Duty time 100 %
Dimensions (W x H x D) 18 x 91 x 57.5 mm (0.71 x 3.58 x 2.26 in)
53 x 91 x 57.5 mm (2.09 x 3.58 x 2.26 in)
71 x 91 x 57.5 mm (2.80 x 3.58 x 2.26 in)
89.9 x 91 x 57,5 mm (3.54 x 3.58 x 2.26 in)
Weight 0.066 kg (0.13 lb) 0.196 kg (0.41 lb) 0.252 kg (0.55 lb) 0.386 kg / (0.72 lb)
Material of housing plastic
Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool
Mounting position horizontal
Minimum distance to other units horizontal / vertical 25 mm / 25 mm (0.98 in / 0.98 in)
Degree of protection housing / terminals IP20 / IP20
Protection class II
3
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/14
CP-D range
Technical data
Data at Ta = 25 °C, U
in = 230 V AC and rated values, unless otherwise indicated
Type CP-D 24/0.42 CP-D 24/1.3 CP-D 24/2.5 CP-D 24/4.2
Electrical connection - Input circuit / Output circuitWire size fine-strand with wire end ferrule 0.2-1.5 mm2
(24-16 AWG)0.2-2.5 mm2 (24-14 AWG)
rigid 0.2-2.5 mm2 (26-12 AWG)
0.2-2.5 mm2 (24-12 AWG)
Stripping length 4-5 mm (0.16-0.2 in) 7 mm (0.28 in)
Tightening torque 0.6 Nm (5 lb.in) 0.7 Nm (6 lb.in)
Environmental data
Ambient temperature range operation -40…+70 °C
rated load -40…+60 °C -40…+55 °C -40…+60 °C
storage -40…+85 °C
Damp heat (cyclic) (IEC/EN 60068-2-30) 4 x 24 cycles, 40 °C, 95 % RH
Vibration (sinusoidal) (IEC/EN 60068-2-6) 50 m/s2, 10 Hz - 2 kHz
Shock (half-sine) (IEC/EN 60068-2-27) 40 m/s2, 22 ms
Isolation data
Rated insulation voltage Ui
input circuit / output circuit 3 kV AC 4 kV AC 3 kV AC
Pollution degree 2
Overvoltage category (UL/IEC/EN 60950-1) ll
Standards
Product standard EN 61204
Low Voltage Directive 2006/95/EC
EMC Direcitve 2004/108/EC
Electrical safety UL 508, UL 60950-1, EN 60950-1
Protective low voltage SELV (EN 60950-1)
Electromagnetic compatibility
Interference immunity to EN 61000-6-2
electrostatic discharge IEC/EN 61000-4-2 Level 4 (4 kV / 8 kV)
Level 4 (4 kV / 15 kV)
Level 4 (4 kV / 8 kV)
radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 Level 3 (10 V/m)
electrical fast transient/burst IEC/EN 61000-4-4 Level 4 (4 kV)
surge IEC/EN 61000-4-5 Level 3 (2 kV L-L)
conducted disturbances, induced by radio-frequency fields
IEC/EN 61000-4-6 Level 3 (10 V)
Interference emission EN 61000-6-3
high-frequency radiated IEC/CISPR 22, EN 55022 Class B
high-frequency conducted IEC/CISPR 22, EN 55022 Class B
„Approvals and marks“ on page 3/4.
3
3/15 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
CP-D range
Technical diagrams
CP-D except CP-D 24/2.5 CP-D 24/2.5
CP-D 12/0.83 CP-D 12/2.1
CP-D 24/0.42 CP-D 24/1.3
CP-D 24/2.5 CP-D 24/4.2
Characteristic curve of output at Ta = 25 °C
-10 0 10 20 30 40 50 60 70
10
203040
50
6070
8090
100
2C
DC
272 0
18 F
0207
Pout [%]
Ta [°C]-10 0 10 20 30 40 50 60 70
10
203040
50
6070
8090
100
Pout [%]
Ta [°C]
2C
DC
27
2 0
18
F0
20
7
0
10
234
5
67
89
10
1112
2C
DC
272 0
19 F
0207
Uout [V]
Iout [A]0.50.25 0.75 1 1.25 0
10
234
5
67
89
10
1112
2C
DC
272 0
20 F
0207
Uout [V]
Iout [A]0.5 1 1.5 2 2.5 3 43.5
0
20
468
10
1214
161820
2224
2C
DC
272 0
21 F
0207
Uout [V]
Iout [A]0.125 0.25 0.5 0.6250.375 0.8750.75 0
20
468
10
1214
161820
2224
2C
DC
272 0
22 F
0207
Uout [V]
Iout [A]0.5 1 1.5 2 2.5 3
0
20
468
10
1214
161820
2224
2C
DC
272 0
23 F
0207
Uout [V]
Iout [A]0.5 1 1.5 2 2.5 3 43.5 0
20
468
10
1214
161820
2224
1 2 3 4 5 6 87
2C
DC
272 0
30 F
0207
Uout [V]
Iout [A]
Characteristic curve of temperature at rated output voltage
3
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/16
CP-D range
Dimensional drawings
CP-D 24/4.2
CP-D 12/2.1, CP-D 24/1.3
CP-D 24/2.5
CP-D 12/0.83, CP-D 24/0.42
Dimensional drawings dimensions in mm
18,0 [0.71”]
67,0 [2.64”]
44,5 [1.75”]
91
,0 [
3.5
8”]
32
,1 [
1.2
6”]
57
,5 [
2.2
6”]
49
,0 [
1.9
3”]
2CD
C 2
72 0
11 F
0b07
67,0 [2.64”]
44,5 [1.75”]
32
,1 [
1.2
6”]
57
,5 [
2.2
6”]
49
,0 [
1.9
3”]
91
,0 [
3.5
8”]
53,0 [2.09”]
2CD
C 2
72 0
12 F
0b07
67,0 [2.64”]
44,5 [1.75”]
32
,1 [
1.2
6”]
57
,5 [
2.2
6”]
49
,0 [
1.9
3”]
91
,0 [
3.5
8”]
71,0 [2.80”]
2CD
C 2
72 0
13 F
0b07
67,0 [2.64”]
44,5 [1.75”]
32
,1 [
1.2
6”]
57
,5 [
2.2
6”]
49
,0 [
1.9
3”]
91
,0 [
3.5
8”]
89,9 [3.54”]
2CD
C 2
72 0
14 F
0b07
3
3/17 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
CP-E range
Product group picture
3
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/18
CP-E range
Table of contents
CP-E range
Product group picture 3/17
Table of contents 3/18
Benefits and advantages 3/19
Ordering details 3/20
Technical data 3/21
Technical diagrams, Wiring instructions 3/29
Technical diagrams, Dimensional drawings 3/30
3
3/19 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
2C
DC
27
6 0
08
F0
00
6
2C
DC
27
6 0
08
F0
00
6
2C
DC
27
1 0
06
F0
00
3
2C
DC
27
6 0
09
F0
00
6
Characteristics – Output voltages 5 V, 12 V, 24 V, 48 V DC
– Adjustable output voltages
– Output currents 0.625 A / 0.75 A / 1.25 A / 2.5 A / 3 A /
5 A / 10 A / 20 A
– Power range 15 W, 18 W, 30 W, 60 W, 120 W, 240 W, 480 W
– High efficiency of up to 90 %
– Low power dissipation and low heating
– Free convection cooling (no forced cooling with ventilators)
– Ambient temperature range during operation -40...+70 °C
– Open-circuit, overload and short-circuit stable
– Integrated input fuse
– U/I characteristic curve on devices > 18 W
(fold-forward behaviour at overload – no switch-off)
– Redundancy units offering true redundancy
– LED(s) for status indication
– Signalling output/contact for output voltage OK
Transistor on 24 V devices > 18 W and < 120 W
– Solid-state on 24 V devices � 120 W
– Approvals / Marks
(depending on device, partly pending):
– A, H, R, E / a, b
Signalling output/contactThe CP-E range 24 V devices > 18 W offer an output/contact
for monitoring of the output voltage and remote diagnosis.
Wide range inputOptimised for world-wide applications: The CP-E power
supplies can be supplied within a wide range of AC or DC
voltage.
Adjustable output voltageThe CP-E range types feature a continuously adjustable
output voltage. Thus, they can be optimally adapted to the
application, e.g. compensating the voltage drop caused by a
long line length.
Redundancy unitsFor decoupling of parallelized power supply units � 40 V.
Thus, true redundancy can be achieved.
Further information about redundancy unit on page 51.
Benefits
1
1
2
2
3
3
4
4
CP-E range
Benefits and advantages
4
1
2
3
5
1 INPUT L, N, PE: terminals - input
2 Circuit diagram
3 single/parallel: sliding switch - adjustment of single or parallel operation
4 Indication of operational states DC ON: green LED - green LED - output voltage OK
DC LOW: red LED - output voltage too low
5 OUTPUT L+, L+, L-, L-: terminals - output OUTPUT Adjust: potentiometer - adjustment of output voltage
3
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/20
Description
This range offers types with output voltages from 5 V DC to 48 V DC at output currents of
0.625 A to 20 A. The high thermal efficiency of up to 90 %, corresponding to very low power
and heat dissipation, allows operation without forced cooling. The functionality has been en-
hanced while the number of different types has been considerably reduced.
Of course all power supplies of the CP-E range are approved in accordance with all relevant
international standards.
Ordering details - CP-E < 100 WInput voltage range Rated output
voltage / currentType Order code Price
1 pce
Weight(1 pce)kg (lb)
90-264 V AC / 120-375 V DC 5 V DC / 3 A CP-E 5/3.0 1SVR427033R30000.15 (0.33)
85-264 V AC / 90-375 V DC 12 V DC / 2.5 A CP-E 12/2.5 1SVR427032R10000.29 (0.64)
90-132 V AC, 180-264 V AC / 210-375 V DC
12 V DC / 10 A CP-E 12/10.0 1SVR427035R10001.00 (2.20)
90-264 V AC / 120-375 V DC 24 V DC / 0.75 A CP-E 24/0.75 1SVR427030R00000.15 (0.33)
85-264 V AC / 90-375 V DC 24 V DC / 1.25 A CP-E 24/1.25 1SVR427031R00000.29 (0.64)
85-264 V AC / 90-375 V DC 24 V DC / 2.5 A CP-E 24/2.5 1SVR427032R00000.36 (0.79)
Ordering details - CP-E M 120 WInput voltage range Rated output
voltage / currentType Order code Price
1 pce
Weight(1 pce)kg (lb)
90-132 V AC, 180-264 V AC / 210-375 V DC
24 V DC / 5 A CP-E 24/5.0 1SVR427034R00001.00 (2.20)
90-132 V AC, 180-264 V AC / 210-375 V DC
24 V DC / 10 A CP-E 24/10.0 1SVR427035R00001.36 (3.01)
90-264 V AC / 120-375 V DC 24 V DC / 20 A CP-E 24/20.0 1SVR427036R00001.90 (4.18)
85-264 V AC / 90-375 V DC 48 V DC / 0.625 A CP-E 48/0.62 1SVR427030R20000.29 (0.64)
85-264 V AC / 90-375 V DC 48 V DC / 1.25 A CP-E 48/1.25 1SVR427031R20000.36 (0.79)
90-132 V AC, 180-264 V AC / 210-375 V DC
48 V DC / 5 A CP-E 48/5.0 1SVR427034R20001.36 (3.01)
90-264 V AC / 120-375 V DC 48 V DC / 10 A CP-E 48/10.0 1SVR427035R20001.90 (4.19)
2C
DC
27
1 0
13
F0
00
62
CD
C 2
71
02
8 F
00
08
2C
DC
27
1 0
17
F0
00
6
CP-E 12/2.5
CP-E 48/5.0
CP-E 24/0.75
CP-E range
Ordering details
3
3/21 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
CP-E range
Technical data
Data at Ta = 25 °C, U
in = 230 V AC and rated values, unless otherwise indicated
Type CP-E 5/3.0 CP-E 12/2.5 CP-E 12/10.0
Input circuit L, NRated input voltage U
in100-240 V AC 115 / 230 V AC
auto selectInput voltage range 90-264 V AC /
120-375 V DC85-264 V AC / 90-375 V DC
90-132 V AC, 180-264 V AC / 210-375 V DC
Frequency range AC 47-63 Hz
Typical input current at 115 V AC 335 mA 560 mA 2.2 A
at 230 V AC 210 mA 330 mA 0.83 A
Typical power consumption 19.8 W 35.9 W 143 W
Inrush current limiting at 115 V AC 10 A (max. 3 ms) 20 A (max. 3 ms) 24 A (max. 5 ms)
at 230 V AC 18 A (max. 3 ms) 40 A (max. 3 ms) 48 A (max. 5 ms)
Discharge current input / output 0.25 mA
input / PE 3.5 mA
Power failure buffering time at 115 V AC min. 20 ms min. 20 ms min. 25 ms
at 230 V AC min. 75 ms min. 30 ms min. 30 ms
Internal input fuse 2 A slow-acting / 250 V AC 3.15 A slow-acting / 250 V AC
Power factor correction (PFC) no yes, passive, 0.7
Indication of operational statesOutput voltage green LED OK: V:
output voltage OKOUTPUT OK: V: output voltage OK
OUTPUT OK: V: output voltage OK
red LED LOW: V: output voltage too low
- OUTPUT LOW: V: output voltage too low
Output circuit L+,L- L+, L+, L-, L-
Rated output voltage 5 V DC 12 V DC
Tolerance of the output voltage 0...+1 %
Adjustment range of the output voltage 4.5-5.75 V DC 12-14 V DC 11.4-14.5 V DC
Rated output power 15 W 30 W 120 W
Rated output current Ir
Ta � 60 °C 3.0 A 2.5 A 10 A
Derating of the output current 60 °C < Ta � 70 °C 2.5 %/°C 2.5 %/°C
Maximum deviation with load change statical ±2 % ±0.5 % ±1 % (single mode)±5 % (parallel mode)
change of output voltage within the input voltage range
±1 % ±0.5 % ±0.5 %
Control time < 2 ms
Starting time after applying the supply voltage at Ir
max. 1 s
with 3500 μF - max. 2 s -
with 7000 μF max. 1.5 s - max. 1.5 s
Rise time at rated load max. 150 ms
with 3500 μF - max. 500 ms -
with 7000 μF max. 500 ms - max. 500 ms
Fall time max. 150 ms
Residual ripple and switching peaks BW = 20 MHz 50 mV
Parallel connection yes, to enable redundancy configurable, to increase power,up to 3 devices, min. 0.1 I
r - max. 0.9 I
r
Series connection yes, to increase voltage yes, to increase voltage, max. 2 devices
Resistance to reverse feed 1 s - max. 7.5 V DC 1 s - max.18 V DC max. 18 V DC
Output circuit - No-load, overload and short-circuit behaviour
Characteristic curve of output Hiccup-mode U/I characteristic curve
Short-circuit protection continuous short-circuit proof
Short-circuit behaviour Hiccup-mode continuation with output power limiting
Overload protection output power limiting
No-load protection continuous no-load stability
Starting of capacitive loads 7000 μF 3500 μF 7000 μF
3
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/22
CP-E range
Technical data
Data at Ta = 25 °C, U
in = 230 V AC and rated values, unless otherwise indicated
Type CP-E 5/3.0 CP-E 12/2.5 CP-E 12/10.0
General dataPower dissipation typ. 5 W typ. 5.6 W typ. 24 W
Efficiency typ. 75 % typ. 84 % typ. 84 %
Duty time 100 %
Dimensions (W x H x D) 22.5 x 90 x 114 mm (0.89 x 3.54 x 4.49 in)
40.5 x 90 x 114 mm (1.59 x 3.54 x 4.49 in)
63.2 x 123.6 x 123.6 mm (2.49 x 4.87 x 4.87 in)
Weight 0.144 kg (0.317 lb) 0.287 kg (0.633 lb) 0.888 kg (1.958 lb)
Material of housing Plastic Metal
Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool
Mounting position horizontal
Minimum distance to other units horizontal / vertical 25 mm / 25 mm (0.98 in / 0.98 in)
Degree of protection housing / terminals IP20 / IP20
Protection class I
Electrical connection - input circuit / output circuitWire size fine-strand with wire end ferrule 0.2-2.5 mm2 (24-14 AWG) 0.2-4 mm² (24-11 AWG)
fine-strand without wire end ferrule 0.2-6 mm² (24-10 AWG)
rigid
Stripping length 6 mm (0.24 in) 8 mm (0.31 in)
Tightening torque input / output 0.6 Nm (5 lb.in) 1.0 Nm (9 lb.in) / 0.62 Nm (5.5 lb.in)
Environmental dataAmbient temperature range operation -20…+70 °C -40…+70 °C -35…+70 °C
rated load -20...+60 °C -40...+60 °C -35...+60 °C
storage -20…+85 °C -40…+85 °C -40…+85 °C
Damp heat (cyclic) (IEC/EN 60068-2-30) 95 RH, % without condensation
Vibration (sinusoidal) (IEC/EN 60068-2-6) 10-500 Hz, 2 G, along X, Y, Z each axis, 60 min. for each axis
Shock (half-sine) (IEC/EN 60068-2-27) 15 G, 11 ms, 3 axes, 6 faces, 3 times for each face
Isolation data
Rated insulation voltage Ui
input circuit / output circuit 3 kV AC
input / PE 1.5 kV AC
output / PE 0.5 kV AC; 0.71 kV DC
Pollution degree 2
Overvoltage category (UL/IEC/EN 60950-1) II
StandardsProduct standard EN 61204-3
Low Voltage Directive 2006/95/EC
EMC directive 2004/108/EC
RoHS directive 2011/65/EC
Electrical safety EN 60950-1, UL 60950-1, UL 508
EN 60950-1, UL 60950-1, UL 508, EN 61558-1, EN 61558-2-17; EN 60204-1
Protective low voltage SELV (EN 60950)
Electromagnetic compatibilityInterference immunity to IEC/EN 61000-6-2
electrostatic discharge IEC/EN 61000-4-2 Level 4 (air discharge 15 kV / contact discharge 8 kV)
radiated, radio-frequency, electromagnetic field
IEC/EN 61000-4-3 Level 3 (10 V/m)
electrical fast transient/burst IEC/EN 61000-4-4 Level 4 (4 kV / 2,5 kHz) Level 4 (4 kV / 5 kHz)
surge IEC/EN 61000-4-5 L-L Level 3 (2 kV) / L-PE Level 4 (4 kV)
conducted disturbances, induced by radio-frequency fields
IEC/EN 61000-4-6 Level 3 (10 V)
power frequency magnetic fields IEC/EN 61000-4-8 Level 4 (30 A/m)
voltage dips, short interruptions and voltage variations
IEC/EN 61000-4-11 dip: >95 % 10 ms / >30 % 500 msinterruptions: >95 % 5000 ms
Interference emission IEC/EN 61000-6-3high-frequency radiated IEC/CISPR 22, EN 55022 Class B
high-frequency conducted IEC/CISPR 22, EN 55022 Class B
limits for harmonic current emissions IEC/EN 61000-3-2 Class D Class A Class D
„Approvals and marks“ on page 3/4.
3
3/23 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
CP-E range
Technical data
Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated
Type CP-E 24/0.75 CP-E 24/1.25 CP-E 24/2.5
Input circuit L, NRated input voltage U
in100-240 V AC
Input voltage range 90-264 V AC / 120-375 V DC
85-264 V AC / 90-375 V DC
Frequency range AC 47-63 Hz
Typical input current at 115 V AC 335 mA 560 mA 1060 mA
at 230 V AC 210 mA 330 mA 590 mA
Typical power consumption 22.8 W 36.7 W 69.2 W
Inrush current limiting at 115 V AC 10 A (max. 3 ms) 20 A (max. 3 ms) 20 A (max. 3 ms)
at 230 V AC 18 A (max. 3 ms) 40 A (max. 3 ms) 40 A (max. 3 ms)
Discharge current input / output 0.25 mA
input / PE 3.5 mA
Power failure buffering time at 115 V AC min. 20 ms min. 20 ms
at 230 V AC min. 75 ms min. 30 ms
Internal input fuse 2 A slow-acting / 250 V AC
Power factor correction (PFC) no
Indication of operational statesOutput voltage green LED OK: V:
output voltage OKOUTPUT OK: V: output voltage OK
red LED LOW: V: output voltage too low
- -
Output circuit L+,L- L+, L+, L-, L-Rated output voltage 24 V DC
Tolerance of the output voltage 0 ... +1 %
Adjustment range of the output voltage 21.6-28.8 V DC 24-28 V DC
Rated output power 18 W 30 W 60 W
Rated output current Ir
Ta � 60 °C 0.75 A 1.25 A 2.5 A
Derating of the output current 60 °C < Ta � 70 °C 2.5 %/°C
Signalling output for output voltage OK DC OK - transistor
Maximum deviation with load change statical ±2 % ±0.5 %
change of output voltage within the input voltage range
±1 % ±0.5 %
Control time < 2 ms
Starting time after applying the supply voltage at Ir
max. 1 s
with 3500 μF - max. 2 s -
with 7000 μF max. 1.5 s - max. 1.5 s
Rise time at rated load max. 150 ms
with 3500 μF - max. 500 ms -
with 7000 μF max. 500 ms - max. 500 ms
Fall time max. 150 ms
Residual ripple and switching peaks BW = 20 MHz 50 mV
Parallel connection yes, to enable redundancySeries connection yes, to increase voltageResistance to reverse feed 1 s - max. 35 V DC
Output circuit - No-load, overload and short-circuit behaviourCharacteristic curve of output Hiccup-mode U/I characteristic curve
Short-circuit protection continuous short-circuit proof
Short-circuit behaviour Hiccup-mode continuation with output power limiting
Overload protection output power limiting
No-load protection continuous no-load stability
Starting of capacitive loads 7000 μF 3500 μF 7000 μF
3
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/24
CP-E range
Technical data
Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated
Type CP-E 24/0.75 CP-E 24/1.25 CP-E 24/2.5General dataPower dissipation typ. 4.45 W typ. 5.5 W typ. 8.8 W
Efficiency typ. 77 % typ. 86 % typ. 89 %
Duty time 100 %
Dimensions (W x H x D) 22.5 x 90 x 114 mm (0.89 x 3.54 x 4.49 in)
40.5 x 90 x 114 mm (1.59 x 3.54 x 4.49 in)
Weight 0.143 kg (0.315 lb) 0.270 kg (0.60 lb) 0.331 kg (0.73 lb)
Material of housing Plastic
Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool
Mounting position horizontal
Minimum distance to other units horizontal / vertical 25 mm / 25 mm (0.98 in / 0.98 in)
Degree of protection housing / terminals IP20 / IP20
Protection class I
Electrical connection - input circuit / output circuitWire size fine-strand with wire end ferrule 0.2-2.5 mm2 (24-14 AWG)
fine-strand without wire end ferrule
rigid
Stripping length 6 mm (0.24 in)
Tightening torque input / output 0.6 Nm (5 lb.in)
Environmental dataAmbient temperature range operation -20…+70 °C -40…+70 °C
rated load -20…+60 °C -40…+60 °C
storage -20…+85 °C -40…+85 °C
Damp heat (cyclic) (IEC/EN 60068-2-30) 95 % RH, without condensation
Vibration (sinusoidal) (IEC/EN 60068-2-6) 10-500 Hz, 2 G, along X, Y, Z each axis, 60 min. for each axis
Shock (half-sine) (IEC/EN 60068-2-27) 15 G, 11 ms, 3 axes, 6 faces, 3 times for each face
Isolation dataRated insulation voltage U
iinput circuit / output circuit 3 kV AC
input / PE 1.5 kV AC
output / PE 0.5 kV AC; 0.71 kV DC
Pollution degree 2
Overvoltage category (UL/IEC/EN 60950-1) II
StandardsProduct standard EN 61204-3
Low Voltage Directive 2006/95/EC
EMC directive 2004/108/EC
RoHS directive 2011/65/EC
Electrical safety EN 50178, EN 60950-1, UL 60950-1, UL 508
EN 60950-1, UL 60950-1, UL 508, EN 61558-1, EN 61558-2-17; EN 60204-1
Protective low voltage SELV (EN 60950)
Electromagnetic compatibilityInterference immunity to IEC/EN 61000-6-2
electrostatic discharge IEC/EN 61000-4-2 Level 4 (air discharge 15 kV / contact discharge 8 kV)
radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 Level 3 (10 V/m)
electrical fast transient/burst IEC/EN 61000-4-4 Level 4 (4 kV / 2.5 kHz) Level 4 (4 kV / 5 kHz)
surge IEC/EN 61000-4-5 L-L Level 3 (2 kV) / L-PE Level 4 (4 kV)
conducted disturbances, induced by radio-frequency fields
IEC/EN 61000-4-6 Level 3 (10 V)
power frequency magnetic fields IEC/EN 61000-4-8 Level 4 (30 A/m)
voltage dips, short interruptions and voltage variations
IEC/EN 61000-4-11 dip: >95 % 10 ms / >30 % 500 ms, interruptions: >95 % 5000 ms
Interference emission IEC/EN 61000-6-3
high-frequency radiated IEC/CISPR 22, EN 55022 Class B
high-frequency conducted IEC/CISPR 22, EN 55022 Class B
limits for harmonic current emissions IEC/EN 61000-3-2 Class D Class A
„Approvals and marks“ on page 3/4.
3
3/25 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
CP-E range
Technical data
Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated
Type CP-E 24/5.0 CP-E 24/10.0 CP-E 24/20.0
Input circuit L, NRated input voltage U
in115 / 230 V AC auto select 115-230 V AC
Input voltage range 90-132 V AC, 180-264 V AC / 210-375 V DC
90-132 V AC, 180-264 V AC / 210-375 V DC
90-264 V AC, 120-375 V DC
Frequency range AC 47-63 Hz
Typical input current at 115 V AC 2.2 A 4.0 A 4.9 A
at 230 V AC 0.83 A 1.55 A 2.5 A
Typical power consumption 140 W 270 W 539 W
Inrush current limiting at 115 V AC 24 A (max. 5 ms) 30 A (max. 5 ms) 25 A (max. 5 ms)
at 230 V AC 48 A (max. 5 ms) 60 A (max. 5 ms) 50 A (max. 5 ms)
Discharge current input / output 0.25 mA
input / PE 3.5 mA
Power failure buffering time at 115 V AC min. 25 ms
at 230 V AC min. 30 ms
Internal input fuse 3.15 A slow-acting / 250 V AC
6.3 A slow-acting / 250 V AC
10 A slow-acting / 250 V AC
Power factor correction (PFC) yes, passive, 0.7 yes, active 115 V AC: 0.99 230 V AC: 0.97
Indication of operational statesOutput voltage green LED OUTPUT OK: V: output voltage OK
red LED OUTPUT LOW: V: output voltage too low
Output circuit L+, L+, L-, L-Rated output voltage 24 V DC
Tolerance of the output voltage 0...+1 %
Adjustment range of the output voltage 22.5-28.5 V DC
Rated output power 120 W 240 W 480 W
Rated output current Ir
Ta � 60 °C 5 A 10 A -
Ta � 55 °C - - 20 A
Derating of the output current 60 °C < Ta � 70 °C 2.5 %/°C -
55 °C < Ta � 70 °C - - 2.5 %/°C
Signalling contact for output voltage OK 13-14 solid-state (max. 60 V DC, 0.3 A)
Minimum fuse rating to achieve short-circuit protection 13-14 � 60 V DC, � 0.3 A fast-acting
Maximum deviation with load change statical ±1 % (single mode), ±5 % (parallel mode)
change of output voltage within the input voltage range
±0.5 %
Control time < 2 ms
Starting time after applying the supply voltage at Ir
max. 1 s
with 3500 μF max. 1.5 s - -
with 7000 μF - max. 1.5 s
Rise time at rated load max. 150 ms
with 3500 μF max. 500 ms - -
with 7000 μF - max. 500 ms
Fall time max. 150 ms
Residual ripple and switching peaks BW = 20 MHz 50 mV 100 mV
Parallel connection configurable, to increase power, up to 3 devices, min. 0.1 Ir - max. 0.9 Ir
Series connection yes, to increase voltage, max. 2 devices
Resistance to reverse feed max. 35 V DC
Output circuit - No-load, overload and short-circuit behaviourCharacteristic curve of output U/I characteristic curve
Short-circuit protection continuous short-circuit proof
Short-circuit behaviour continuation with output power limiting
Overload protection output power limiting
No-load protection continuous no-load stability
Starting of capacitive loads 3500 μF 7000 μF
3
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/26
CP-E range
Technical data
Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated
Type CP-E 24/5.0 CP-E 24/10.0 CP-E 24/20.0
General dataPower dissipation typ. 20 W typ. 35 W typ. 63 W
Efficiency typ. 86 % typ. 89 % typ. 89 %
Duty time 100 %
Dimensions (W x H x D) 63.2 x 123.6 x 123.6 mm (2.49 x 4.87 x 4.87 in)
83 x 123.6 x 123.6 mm (3.27 x 4.87 x 4.87 in)
175 x 123.6 x 123.6 mm (6.89 x 4.87 x 4.87 in)
Weight 0.882 kg (1.945 lb) 1.334 kg (2.941 lb) 1.850 kg (4.079 lb)
Material of housing Metal
Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool
Mounting position horizontal
Minimum distance to other units horizontal / vertical 25 mm / 25 mm (0.98 in / 0.98 in)
Degree of protection housing / terminals IP20 / IP20
Protection class I
Electrical connection - input circuit / output circuitWire size fine-strand with wire end ferrule 0.2-4 mm² (24-11 AWG)
fine-strand without wire end ferrule
0.2-6 mm² (24-10 AWG)
rigid
Stripping length 8 mm (0.31 in)
Tightening torque input / output 1.0 Nm (9 lb.in) / 0.62 Nm (5.5 lb.in)
Environmental dataAmbient temperature range operation -35…+70 °C -40…+70 °C
rated load -35…+60 °C -40…+60 °C -40…+55 °C
storage -40…+85 °C -40…+85 °C
Damp heat (cyclic) (IEC/EN 60068-2-30) 95 %RH, without condensation
Vibration (sinusoidal) (IEC/EN 60068-2-6) 10-500 Hz, 2 G, along X, Y, Z each axis, 60 min. for each axis
Shock (half-sine) (IEC/EN 60068-2-27) 15 G, 11 ms, 3 axes, 6 faces, 3 times for each face
Isolation dataRated insulation voltage U
iinput circuit / output circuit 3 kV AC
input / PE 1.5 kV AC
output / PE 0.5 kV AC; 0.71 kV DC
signalling contact / PE 0.5 kV DC
Pollution degree 2
Overvoltage category (UL/IEC/EN 60950-1) II
Standards
Product standard EN 61204-3
Low Voltage Directive 2006/95/EC
EMC directive 2004/108/EC
RoHS directive 2011/65/EC
Electrical safety EN 60950-1, UL 60950-1, UL 508, EN 61558-1, EN 61558-2-17; EN 60204-1
Protective low voltage SELV (EN 60950)
Electromagnetic compatibility
Interference immunity to IEC/EN 61000-6-2
electrostatic discharge IEC/EN 61000-4-2 Level 4 (air discharge 15 kV / contact discharge 8 kV)
radiated, radio-frequency, electromagnetic field
IEC/EN 61000-4-3 Level 3 (10 V/m)
electrical fast transient/burst IEC/EN 61000-4-4 Level 4 (4 kV / 5 kHz) Level 4 (4 kV / 2.5 kHz)
surge IEC/EN 61000-4-5 L-L Level 3 (2 kV) / L-PE Level 4 (4 kV)
conducted disturbances, induced by radio-frequency fields
IEC/EN 61000-4-6 Level 3 (10 V)
power frequency magnetic fields IEC/EN 61000-4-8 Level 4 (30 A/m)
voltage dips, short interruptions and voltage variations
IEC/EN 61000-4-11 dip: >95 % 10 ms / >30 % 500 msinterruptions: >95 % 5000 ms
Interference emission IEC/EN 61000-6-3
high-frequency radiated IEC/CISPR 22, EN 55022 Class B
high-frequency conducted IEC/CISPR 22, EN 55022 Class B
limits for harmonic current emissions Class D
„Approvals and marks“ on page 3/4.
3
3/27 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
CP-E range
Technical data
Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated
Type CP-E 48/0.62 CP-E 48/1.25 CP-E 48/5.0 CP-E 48/10.0
Input circuit L, NRated input voltage U
in 100-240 V AC115 / 230 V AC auto select
115-230 V AC
Input voltage range85-264 V AC / 90-375 V DC
90-132 V AC, 180-264 V AC / 210-375 V DC
90-264 V AC, 120-375 V DC
Frequency range AC 47-63 HzTypical input current at 115 V AC 560 mA 1060 mA 4.0 A 4.9 A
at 230 V AC 330 mA 590 mA 1.55 A 2.5 A
Typical power consumption 35.7 W 69.0 W 267 W 528 W
Inrush current limiting at 115 V AC 20 A (max. 3 ms) 20 A (max. 3 ms) 30 A (max. 5 ms) 25 A (max. 5 ms)
at 230 V AC 40 A (max. 3 ms) 40 A (max. 3 ms) 60 A (max. 5 ms) 50 A (max. 5 ms)
Discharge current input / output 0.25 mA
input / PE 3.5 mA
Power failure buffering time at 115 V AC min. 20 ms min. 25 ms min. 25 ms
at 230 V AC min. 30 ms
Internal input fuse2 A slow-acting / 250 V AC
6.3 A slow-acting / 250 V AC
10 A slow-acting / 250 V AC
Power factor correction (PFC)no yes, passive, 0.7
yes, active 115 V AC: 0.99 230 V AC: 0.97
Indication of operational statesOutput voltage green LED OUTPUT OK: V: output voltage OK
red LED- -
OUTPUT LOW: V: output voltage too low
Output circuit L+, L+, L-, L-Rated output voltage 48 V DC
Tolerance of the output voltage 0...+1 %
Adjustment range of the output voltage 48-55 V DC 47-56 V DC
Rated output power 30 W 60 W 240 W 480 W
Rated output current Ir
Ta � 60 °C 0.625 A 1.25 A 5 A -
Ta � 55 °C - - - 10 A
Derating of the output current 60 °C < Ta � 70 °C 2.5 %/°C -
55 °C < Ta � 70 °C - - - 2.5 %/°C
Signalling output for output voltage OK DC OK - - - -
Maximum deviation with load change statical±0.5 %
±1 % (single mode) ±5 % (parallel mode)
change of output voltage within the input voltage range
±0.5 % ±0.5 %
Control time < 2 ms
Starting time after applying the supply voltage at Ir max. 1 s
with 3500 μF max. 2 s - - -
with 7000 μF - max. 1.5 s max. 1.5 s
Rise time at rated load max. 150 ms
with 3500 μF max. 500 ms - - -
with 7000 μF - max. 500 ms max. 500 ms
Fall time max. 150 ms
Residual ripple and switching peaks BW = 20 MHz 50 mV 100 mV
Parallel connection
yes, to enable redundancyconfigurable, to increase power, up to 3 devices, min. 0.1 I
r - max. 0.9 I
r
Series connectionyes, to increase voltage
yes, to increase voltage, max. 2 devices
Resistance to reverse feed 1 s - max. 63 V DC
Output circuit - No-load, overload and short-circuit behaviourCharacteristic curve of output U/I characteristic curve
Short-circuit protection continuous short-circuit proof
Short-circuit behaviour continuation with output power limiting
Overload protection output power limiting
No-load protection continuous no-load stability
Starting of capacitive loads 3500 μF 7000 μF unlimited 7000 μF
3
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/28
CP-E range
Technical data
Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated
Type CP-E 48/0.62 CP-E 48/1.25 CP-E 48/5.0 CP-E 48/10.0
General dataPower dissipation typ. 4.9 W typ. 7.8 W typ. 32 W typ. 60 W
Efficiency typ. 86 % typ. 89 % typ. 90 %
Duty time 100 %
Dimensions (W x H x D)40.5 x 90 x 114 mm (1.59 x 3.54 x 4.49 in)
83 x 123.6 x 123.6 mm (3.27 x 4.87 x 4.87 in)
175 x 123.6 x 123.6 mm (6.89 x 4.87 x 4.87 in)
Weight 0.264 kg (0.582 lb) 0.316 kg (0.697 lb) 1.322 kg (2.915 lb) 1.839 kg (4.054 lb)
Material of housing Plastic Metal
Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool
Mounting position horizontal
Minimum distance to other units horizontal / vertical 25 mm / 25 mm (0.98 in / 0.98 in)
Degree of protection housing / terminals IP/20 / IP20
Protection class I
Electrical connection - input circuit / output circuitWire size fine-strand with wire end ferrule
0.2-2.5 mm² (24-14 AWG)
0.2-4 mm² (24-11 AWG)
fine-strand without wire end ferrule0.2-6 mm² (24-10 AWG)
rigid
Stripping length 6 mm (0.24 in) 8 mm (0.31 in)
Tightening torque input / output 0.6 Nm (5 lb.in) 1.0 Nm (9 lb.in) / 0.62 Nm (5.5 lb.in)
Environmental dataAmbient temperature range operation -40…+70 °C
rated load -40…+60 °C -40…+55 °C
storage -40…+85 °C
Damp heat (cyclic) (IEC/EN 60068-2-30) 95 % RH, without condensation
Vibration (sinusoidal) (IEC/EN 60068-2-6) 10-500 Hz, 2 G, along X, Y, Z each axis, 60 min. for each axis
Shock (half-sine) (IEC/EN 60068-2-27) 15 G, 11 ms, 3 axes, 6 faces, 3 times for each face
Isolation data
Rated insulation voltage Ui
input circuit / output circuit 3 kV AC
input / PE 1.5 kV AC
output / PE 0.5 kV AC; 0.71 kV DC
Pollution degree 2
Overvoltage category (UL/IEC/EN 60950-1) II
Standards
Product standard EN 61204-3
Low Voltage Directive 2006/95/EC
EMC directive 2004/108/EC
RoHS directive 2011/65/EC
Electrical safety EN 60950-1, UL 60950-1, UL 508, EN 61558-1, EN 61558-2-17; EN 60204-1
Protective low voltage SELV (EN 60950)
Electromagnetic compatibility
Interference immunity to IEC/EN 61000-6-2
electrostatic discharge IEC/EN 61000-4-2 Level 4 (air discharge 15 kV / contact discharge 8 kV)
radiated, radio-frequency, electromagnetic field
IEC/EN 61000-4-3Level 3 (10 V/m)
electrical fast transient/burst IEC/EN 61000-4-4 Level 4 (4 kV / 5 kHz) Level 4 (4 kV / 2.5 kHz)
surge IEC/EN 61000-4-5 L-L Level 3 (2 kV) / L-PE Level 4 (4 kV)
conducted disturbances, induced by radio-frequency fields
IEC/EN 61000-4-6Level 3 (10 V/m)
power frequency magnetic fields IEC/EN 61000-4-8 Level 4 (30 A/m)
voltage dips, short interruptions and voltage variations
IEC/EN 61000-4-11dip: >95 % 10 ms / >30 % 500 ms, interruptions: >95 % 5000 ms
Interference emission IEC/EN 61000-6-3
high-frequency radiated IEC/CISPR 22, EN 55022 Class B
high-frequency conducted IEC/CISPR 22, EN 55022 Class B
limits for harmonic current emissions Class A Class D
„Approvals and marks“ on page 3/4.
3
3/29 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
CP-E range
Technical diagrams, Wiring instructions
Uout [V]
Iout [A] 1.25 1.35 1.45 1.55 1.65 1.75 1.85 1.95 2.05 2.15
2C
DC
27
2 0
06
F0
b0
7
Uout [V]
Iout [A] 2.75 2.85 2.95 3.05 3.15 3.25 3.35 3.45 3.55 3.65
2C
DC
27
2 0
07
F0
b0
7
Uout [V]
Iout [A] 2.8 2.9 3.0 3.1 3.2 3.3 3.4 3.5 3.6 3.7
1
3
5
7
9
11
13
152
CD
C 2
72
00
8 F
0b
07
Uout [V]
Iout [A] 1.73 1.81 1.89 1.97 2.051.33 1.41 1.49 1.57 1.65
10
20
30
40
50
60
70
2C
DC
27
2 0
10
F0
b0
7
CP-E 24/1.25
CP-E 24/2.5
CP-E 12/2.5
CP-E 48/0.62 CP-E 48/1.25
Uout [V]
Iout [A] 0.865 0.905 0.945 0.985 1.0250.665 0.705 0.745 0.785 0.825
10
20
30
40
50
60
70
2C
DC
27
2 0
09
F0
b0
7
Uout [V]
Iout [A] 4 6 8 10 14 16122
2
4
6
8
10
12
14
2C
DC
272 0
05 F
0b
08
CP-E 12/10.0
Uout [V]
Iout [A] 2 3 4 5 7 861
4
8
12
16
20
24
28
2C
DC
272 0
06 F
0b
08
CP-E 24/5.0
Uout [V]
Iout [A] 4 6 8 10 14 16122
4
8
12
16
20
24
28
2C
DC
272 0
07 F
0b
08
CP-E 24/10.0
Uout [V]
Iout [A] 8 12 16 20 28 32244
4
8
12
16
20
24
28
2C
DC
272 0
08 F
0b
08
CP-E 24/20.0
CP-E 48/10.0CP-E 48/5.0
Uout [V]
Iout [A] 2 3 4 5 7 861
8
16
24
32
40
48
56
2C
DC
272 0
09 F
0b
08
Uout [V]
Iout [A] 4 6 8 10 14 16122
8
16
24
32
40
48
56
2C
DC
272 0
10 F
0b
08
CP-E 24/1.25, CP-E 24/2.5
Output curve at Ta = 25 °C
Wiring instructions
DC OK
L-L-
DC OK
2CD
C 2
72 0
17 F
0207
RelayRL > 700 �
5 V Signal
2.2 k�0.5 W
5.1 V0.3 W
3
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/30
Temperature behaviour at Ta = 25 °C
CP-E range
Technical diagrams, Dimensional drawings
CP-E 12/10.0, CP-E 24/5.0
CP-E 5/3.0, CP-E 24/0.75 CP-E 12/2.5, CP-E 24/1.25, CP-E 48/0.62, CP-E 24/2.5, CP-E 48/1.25, CP-E 24/10.0, CP-E 48/5.0
CP-E 24/20.0, CP-E 48/10.0
2C
DC
27
2 0
15
F0
21
12
CD
C 2
72
01
6 F
02
11
2C
DC
27
2 0
17
F0
21
12
CD
C 2
72
01
8 F
02
11
-35 60 70
10
203040
50
6070
8090
100
Pout [%]
Ta [°C]
-20 60 70
10
203040
50
6070
8090
100
Pout [%]
Ta [°C]-40 60 70
10
203040
50
6070
8090
100
Pout [%]
Ta [°C]
-40 55 70
10
203040
50
6070
8090
100
Pout [%]
Ta [°C]
CP-E 5/3.0, CP-E 24/0.75
CP-E 12/2.5, CP-E 24/1.25, CP-E 24/2.5, CP-E 48/0.62, CP-E 48/1.25
CP-E 12/10.0, CP-E 24/5.0
CP-E 24/20.0, CP-E 48/10.0
CP-E 24/10.0, CP-E 48/5.0
175,0 [6.89“]
12
3,6
[4.
87“]
116,6 [4.59“]
123,6 [4.87“] 83,0 [3.27“]
12
3,6
[4.
87“]
63,2 [2.49“]
12
3,6
[4.
87“]
22.5 0.89“114 4.49“
90
3.
54“
40.5 1.59”
90
3.5
4”
2C
DC
27
2
02
1 F
00
11
2C
DC
27
2
01
3 F
00
8
Dimensional drawings dimensions in mm
3
3/31 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
CP-T range
Product group picture
3
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/32
CP-T range
Table of contents
CP-T range
Product group picture 3/31
Table of contents 3/32
Benefits and advantages 3/33
Ordering details 3/34
Technical data 3/35
Technical diagrams, Dimensional drawings 3/39
Technical diagrams 3/40
3
3/33 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
CP-T range
Benefits and advantages
Characteristics – Rated output voltages 24 V, 48 V DC
– Output voltage adjustable via front-face rotary potentiom-
eter “OUTPUT Adjust”
– Rated output currents 5 A, 10 A, 20 A, 40 A
– Rated output powers 120 W, 240 W, 480 W, 960 W
– Three-phase operation (see derating note)
– Two-phase operation (25 % derating possible, see derating note)
– Supply range 3 x 400–500 V AC (3 x 340–575 V AC,
480–820 V DC)
– Typical efficiency of 93 %
– Low power dissipation and low heating
– Free convection cooling (no forced cooling with ventilators)
– Ambient temperature range during operation -40...+70 °C 1)
– Open-circuit, overload and short-circuit stable
– Integrated input fuse
– Redundancy unit CP-A RU offering true redundancy, avail-
able as accessory
– LEDs for status indication
– Signalling contact "13-14" (solid state) for output voltage
OK
– Approvals / marks (depending on device, partly pending):
– A, H, R, E / a , b
1) 480 W variants: -30...+70°C
Signalling outputThe devices of the CP-T series offer a solid state output for
function monitoring and remote diagnostics.
Wide input rangeWide range input optimized for world-wide applications:
The CP-T power supplies can be used in 340 - 575 V AC or
480 - 820 V DC supply systems.
Adjustable output voltageThe CP-T range feature a continuously adjustable output volt-
age. Thus, they can be optimally adapted to the application,
e.g. compensating the voltage drop caused by a long line
length.
Benefits
1
1
2
2
2C
DC
27
1 0
43
S0
00
9
2C
DC
27
1 0
43
S0
00
9
4
1
2
3
5
1 Circuit diagram
2 Indication of operational states DC ON: green LED - green LED - output voltage OK
DC LOW: red LED - output voltage too low
3 single/parallel: sliding switch - adjustment of single or parallel operation
4 Configuration of single or parallel operation
5 Signalling contact OUTPUT 13-14: terminals - signalling contact
A solid-state output indicates the error-free operation of the
output voltage.
OUTPUT L+, L+, L-, L-: terminals - output
7 INPUT L1, L2, L3, PE: terminals - input
7
3
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/34
CP-T range
Ordering details
2C
DC
27
1 0
43
S0
00
9
2C
DC
27
1 0
45
S0
00
92
CD
C 2
71
04
7 S
00
09
CP-T 24/5.0
CP-T 24/10.0, CP-T 48/5.0
CP-T 24/20.0, CP-T 48/10.0
Description
The CP-T range of three-phase power supply units is the youngest member of ABB‘s power
supply family. In terms of design and functionality, the new range perfectly supplements the ex-
isting products and extends the range appropriately. The devices can be supplied with a three-
phase voltage as well as with two-phase mains. Here, ABB offers power supply units with 24 V
DC and 48 V DC outputs with 5 A, 10 A, 20 A and 40 A and efficiency of up to 92 %. As in the
case of all products, they are designed for an ambient temperature of up to 70 °C. All prod-
ucts can be supplied within an AC supply voltage range between 340 to 575 V AC and a DC
supply voltage range between 480 to 820 V DC.
Ordering detailsInput voltage range Rated
output voltage / current
Type Order code Price
1 pce
Weight(1 pce)kg (lb)
340-575 V AC / 480-820 V DC 24 V DC / 5 A CP-T 24/5.0 1SVR427054R00000.80 (1.77)
340-575 V AC / 480-820 V DC 24 V DC / 10 A CP-T 24/10.0 1SVR427055R00001.05 (2.31)
340-575 V AC / 480-820 V DC 24 V DC / 20 A CP-T 24/20.0 1SVR427056R00001.75 (3.86)
340-575 V AC / 480-820 V DC 24 V DC / 40 A CP-T 24/40.0 1SVR427057R00003.20 (7.05)
340-575 V AC / 480-820 V DC 48 V DC / 5 A CP-T 48/5.0 1SVR427054R20001.05 (2.31)
340-575 V AC / 480-820 V DC 48 V DC / 10 A CP-T 48/10.0 1SVR427055R20001.75 (3.86)
340-575 V AC / 480-820 V DC 48 V DC / 20 A CP-T 48/20.0 1SVR427056R20003.40 (7.50)
3
3/35 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
CP-T range
Technical data
Data at Ta = 25 °C, Uin = 3 x 400 V AC and rated values, unless otherwise indicated
Type CP-T 24/5.0 CP-T 24/10.0 CP-T 24/20.0 CP-T 24/40.0
Input circuit L1, L2, L3Rated input voltage U
in3 x 400-500 V AC
Input voltage range 340-575 V AC
480-820 V DC
Frequency range AC 47-63 Hz
Typical input current 0.36 A 0.65 A 1.1 A 1.72 A
Typical power consumption 135 W 270 W 538 W 1058 W
Inrush current limiting 10 A 20 A 30 A
Power failure buffering time min. 20 ms min. 15 ms
Internal input fuse per phase 2 A / 600 V AC T 3.15 A / 500 V AC T 5 A / 500 V AC
Recommended backup fuse 3 pole miniature circuit breaker ABB Type S203
Power factor correction (PFC) Yes, passive
Discharge current towards PE < 3.5 mA
input / output < 0.25 mA
Indication of operational statesOutput voltage OUTPUT OK: green LED output voltage OK
OUTPUT LOW: red LED output voltage too low
Output circuit L+, L+, L-, L-Rated output voltage 24 V DC
Tolerance of the output voltage 0...+1 %
Adjustment range of the output voltage 22.5-28.5 V DC
Rated output power 120 W 240 W 480 W 960 W
Rated output current Ir
Ta 60 °C 5 A 10 A 20 A 40 A
Derating of the output current 60 °C < Ta ≤ 70 °C 2.5 %/°C 3.5 %/°C
Signalling contact for output voltage OK
13-14 solid state (max. 60 V DC, 0.3 A)
Threshold 17.6-19.4 V
Insulation voltage 500 V DC
Mininum fuse rating to achieve short-circuit protection 13-14 � 60 V DC, � 0.3 A fast-acting
Maximum deviation with load change statical ±1 % ±1 % (single mode)
- ±5 % (parallel mode)
change of output voltage within the input voltage range
± 0.5 %
Control time at nominal load < 2 ms
Starting time after applying the supply voltage
at Ir
max. 1 s
with 3500 μF max. 1.5 s
Rise time at nominal load max. 150 ms
with 3500 μF max. 500 ms
Fall time max. 150 ms
Residual ripple and switching peaks BW = 20 MHz 100 mV 80 mV
Parallel connection not supported configurable, to increase power, up to 2 devices, min. 0.1 I
r - max 0.9 I
r)
to increase power, up to 2 devices, min. 0.1 I
r - max.
0.9 Ir use active
current balancing
Series connection not supported yes, to increase voltage, max. 2 devices
Resistance to reverse feed approx. 35 V
Output circuit - No-load, overload and short-circuit behaviourCharacteristic curve of output combined U/I characteristic curve
and hiccup modeU/I- or Hiccup-mode adjustable
hiccup / fold back behavior
Short-circuit protection continuous short-circuit proof
Short-circuit behaviour current limiting
Overload protection hiccup mode
No-load protection continuous no-load stability
Overtemperature protection yes, automatic recovery after temperature went down
Starting of capacitive loads 3500 μF 7000 μF 7000 μF 7000 μF
3
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/36
CP-T range
Technical data
Data at Ta = 25 °C, Uin = 3 x 400 V AC and rated values, unless otherwise indicated
Type CP-T 24/5.0 CP-T 24/10.0 CP-T 24/20.0 CP-T 24/40.0
General dataEfficiency typ. 89 % typ. 90 % typ. 92 %
Duty time 100%
Dimensions (W x H x D) 74.3 x 124 x 118.8 mm(2.92 x 4.88 x 4.68 in)
89 x 124 x 118.8 mm(3.5 x 4.88 x 4.68 in)
150 x 124 x 118.8 mm(5.91 x 4.88 x 4.68 in)
275.8 x 124 x 118.8 mm(10.86 x 4.88 x 4.68 in)
Weight 0.78 kg (1.72 lb) 1.045 kg (2.30 lb) 1.657 kg (3.653 lb) 3.275 kg (7.220 lb)
Material of housing Metal
Mounting DIN rail (IEC EN 60715), snap-on mounting without any tool
Mounting position horizontal
Minimum distance to other units horizontal / vertical 25 mm / 25 mm (0.98 in / 0.98 in)
Degree of protection housing / terminals IP20 / IP20
Protection class I
Electrical connection - input circuit / output circuit / signalling circuitWire size fine-strand with wire end ferrule 0.2-4 mm² (24-11 AWG)
fine-strand without wire end ferrule 0.2-6 mm² (24-10 AWG)
rigid 0.2-6 mm² (24-10 AWG)
Stripping length 8 mm (0.31 in)Tightening torque input / output 1 Nm (9 lb.in) / 0.6 Nm (5.5 lb.in) 1 Nm (9 lb.in) /
1.8 Nm (15.6 lb.in)
Environmental data Ambient temperature range operation -40...+70 °C -30…+70 °C -40...+70 °C
rated load -40...+60 °C -30…+60 °C -40...+60 °C
storage -40…+85 °C
Damp heat (cyclic) (IEC/EN 60068-2-30) 95 % without condensation
Vibration (sinusoidal) (IEC/EN 60068-2-6) 2 g, 10-500 Hz, 2G, each along X, Y, Z axes 60 min / cycle
Shock (half-sine) (IEC/EN 60068-2-27) 15 g, 11 ms, 3 axes, 6 faces, 3 times for each face
Isolation dataRated insulation voltage U
iinput circuit / output circuit 3 kV AC
input / PE 1.5 kV AC
output / PE 0.5 kV AC; 0.71 kV DC
signalling output / PE 0.5 kV DC
Pollution degree 2
StandardsProduct standard EN 61204-3
Low Voltage Directive 2006/95/EC
EMC directive 2004/108/EC
RoHS directive 2011/65/EC
Electrical safety EN 60950-1, UL 60950-1, UL 508, EN 61558-1, EN 61558-2-17; EN 60204-1
Protective low voltage SELV
Electromagnetic compatibilityInterference immunity to IEC/EN 61000-6-2
electrostatic discharge IEC/EN 61000-4-2 Level 4 (air discharge 15 kV / contact discharge 8 kV)
radiated, radio-frequency, electromagnetic field
IEC/EN 61000-4-3 Level 3 (10 V/m)
electrical fast transient/burst IEC/EN 61000-4-4 Level 4 (4 kV / 2.5 kHz)
Level 4 (4 kV / 5 kHz)
surge IEC/EN 61000-4-5 L-L Level 3 (2 kV) / L-PE Level 4 (4 kV)
conducted disturbances, induced by radio-frequency fields
IEC/EN 61000-4-6 Level 3 (10 V)
power frequency magnetic fields IEC/EN 61000-4-8 Level 4 (30 A/m)
voltage dips, short interruptions and voltage variations
IEC/EN 61000-4-11 dips: >95 % 0.5 ms / >30 % 0.5 ms, interruptions: >95 % 250 ms
Interference emission IEC/EN 61000-6-3
high-frequency radiated IEC/CISPR 22, EN 55022 Class B
high-frequency conducted IEC/CISPR 22, EN 55022 Class B
limits for harmonic current emissions IEC/EN 61000-3-2 Class A
„Approvals and marks“ on page 3/4.
3
3/37 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
CP-T range
Technical data
Data at Ta = 25 °C, Uin = 3 x 400 V AC and rated values, unless otherwise indicated
Type CP-T 48/5.0 CP-T 48/10.0 CP-T 48/20.0
Input circuit L1, L2, L3Rated input voltage U
in3 x 400-500 V AC
Input voltage range 340-575 V AC
480-820 V DC
Frequency range AC 47-63 Hz
Typical input current 0.65 A 1.1 A 1.72 A
Typical power consumption 264 W 535 W 1050 W
Inrush current limiting 20 A 30 A
Power failure buffering time min. 20 ms min. 15 ms
Internal input fuse per phase 2 A / 600 V AC T3.15 A / 500 V AC T 5 A / 500 V AC
Power factor correction (PFC) yes, passive
Discharge current towards PE < 3.5 mA
input / output < 0.25 mA
Indication of operational statesOutput voltage OUTPUT OK: green LED output voltage OK
OUTPUT LOW: red LED output voltage too low
Output circuit L+, L+, L-, L-Rated output voltage 48 V DC
Tolerance of the output voltage 0...+1 %
Adjustment range of the output voltage 47-56 V DC
Rated output power 240 W 480 W 960 W
Rated output current Ir
Ta � 60 °C 5 A 10 A 20 A
Derating of the output current 60 °C < Ta � 70 °C 2.5 %/°C 3.5 %/°C
Maximum deviation with load change statical ±1 % (single mode)
± 5 % (parallel mode)
change of output voltage within the input voltage range
±0.5 %
Control time at rated load < 2 ms
Starting time after applying the supply voltage at Ir max. 1 s
with 7000 μF max. 1.5 s
Rise time at rated load max. 150 ms
with 7000 μF max. 500 ms
Fall time max. 150 ms
Residual ripple and switching peaks BW = 20 MHz 100 mV 80 mV
Parallel connection configurable, to increase power, up to 2 devices, min. 0.1 I
r - max 0.9 I
r)
to increase power, up to 2 devices, min. 0.1 I
r
- max. 0.9 Ir use active
current balancing
Series connection yes, to increase voltage, max. 2 devices
Resistance to reverse feed approx. 35 V approx. 63 V approx. 63 V
Output circuit - No-load, overload and short-circuit behaviourCharacteristic curve of output combined U/I and
hiccup modeU/I or hiccup mode, configurable
hiccup mode / fold back behavior
Short-circuit protection continuous short-circuit proof
Short-circuit behaviour current limiting
Overload protection hiccup mode
No-load protection continuous no-load stability
Over temperature protection yes, automatic recovery after temperature went down
Starting of capacitive loads 7000 μF
3
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/38
CP-T range
Technical data
Data at Ta = 25 °C, Uin = 3 x 400 V AC and rated values, unless otherwise indicated
Type CP-T 48/5.0 CP-T 48/10.0 CP-T 48/20.0
General dataEfficiency typ. 91 % typ. 93 %
Duty time 100%
Dimensions (W x H x D) 89 x 124 x 118.8 mm(3.5 x 4.88 x 4.68 in)
150 x 124 x 118.8 mm(5.91 x 4.88 x 4.68 in)
275.8 x 124 x 118.8 mm(10.86 x 4.88 x 4.68 in)
Weight 1.045 kg (2.30 lb) 1.657 kg (3.653 lb) 3.275 kg (7.22 lb)
Material of housing Metal
Mounting DIN rail (IEC EN 60715), snap-on mounting without any tool
Mounting position horizontal
Minimum distance to other units horizontal / vertical 25 mm / 25 mm (0.98 in / 0.98 in)
Degree of protection housing / terminals IP20 / IP20
Protection class I
Electrical connection - input circuit / output circuitWire size fine-strand with wire end ferrule 0.2-4 mm² (24-11 AWG) 0.2-4 mm² (24-11
AWG) / 0.5-10 mm² (20-8 AWG)
fine-strand without wire end ferrule 0.2-6 mm² (24-10 AWG)
rigid
Stripping length 8 mm (0.31 in)
Tightening torque input / output 1 Nm (9 lb.in) / 0.6 Nm (5.5 lb.in) 1 Nm (9 lb.in) / 1.8 Nm (15.6 lb.in)
Environmental data Ambient temperature range operation -40…+70 °C -30…+70 °C -40…+70 °C
rated load -40…+60 °C -30…+60 °C -40…+60 °C
storage -40…+85 °C -40…+85 °C -40…+85 °C
Damp heat (cyclic) (IEC/EN 60068-2-30) 95 % without condensation
Vibration (sinusoidal) (IEC/EN 60068-2-6) 10-500 Hz, 2G, each along X, Y, Z axes 6 min / cycle
Shock (half-sine) (IEC/EN 60068-2-27) 15G, 11 ms, 3 axes, 6 Faces, 3 times for each face
Isolation dataRated insulation voltage U
iinput circuit / output circuit 3 kV AC
input / PE 1.5 kV AC
output / PE 0.5 kV AC; 0.71 kV DC
Pollution degree 2
Standards
Product standard EN 61204-3
Low Voltage Directive 2006/95/EC
EMC directive 2004/108/EC
RoHS directive 2011/65/EC
Electrical safety EN 60950-1, UL 60950-1, UL 508, EN 61558-1, EN 61558-2-16; EN 60204-1
Protective low voltage SELV
Electromagnetic compatibility
Interference immunity to IEC/EN 61000-6-2
electrostatic discharge IEC/EN 61000-4-2 Level 4 (air discharge 15 kV / contact discharge 8 kV)
radiated, radio-frequency, electromagnetic field
IEC/EN 61000-4-3 Level 3 (10 V/m)
electrical fast transient/burst IEC/EN 61000-4-4 Level 4 (4 kV / 5 kHz)
surge IEC/EN 61000-4-5 L-L Level 3 (2 kV) / L-PE Level 4 (4 kV)
conducted disturbances, induced by radio-frequency fields
IEC/EN 61000-4-6 Level 3 (10 V)
power frequency magnetic fields IEC/EN 61000-4-8 Level 4 (30 A/m)
voltage dips, short interruptions and voltage variations
IEC/EN 61000-4-11 dips: >95 % 0.5 ms / >30 % 0.5 msinterruptions: >95 % 250 ms
Interference emission IEC/EN 61000-6-3
high-frequency radiated IEC/CISPR 22, EN 55022 Class B
high-frequency conducted IEC/CISPR 22, EN 55022 Class B
limits for harmonic current emissions
IEC/EN 61000-3-2 Class A
„Approvals and marks“ on page 3/4.
3
3/39 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
CP-T range
Technical diagrams, Dimensional drawings
CP-T 24/5.0
CP-T 24/20.0 Hiccup mode
CP-T 48/10.0 U/I curve
CP-T 24/10.0
CP-T 24/40.0
CP-T 48/10.0 Hiccup mode
CP-T 24/20.0 U/I curve
CP-T 48/5.0
CP-T 48/20.0
CP-T 24/20.0, CP-T 48/10.0CP-T 24/10.0, CP-T 48/5.0 CP-T 24/40.0, CP-T 48/20.0
Output curve at Ta = 25 °C
CP-T 24/5.0
Dimensional drawings dimensions in mm
2C
DC
27
2 0
32
F0
x0
92
CD
C 2
72
03
5 F
0x0
92
CD
C 2
72
03
8 F
0x0
9
2C
DC
27
2 0
33
F0
x0
92
CD
C 2
72
02
7 F
02
11
2C
DC
27
2 0
39
F0
x0
9
2C
DC
27
2 0
34
F0
x0
92
CD
C 2
72
03
7 F
0x0
92
CD
C 2
72
02
8 F
02
11
1 2 3 4 5 6 7 8
4
8
12
16
20
24
28
Uout [V]
Iout [A]
Hiccup mode
@ 3 x 400V supply@ 3 x 500V supply
4 8 12 16 20 24 28 32
4
8
12
16
20
24
28
Uout [V]
Iout [A]
@ 3 x 400V supply
@ 3 x 500V supply
Hiccup mode
2 4 6 8 10 12 14 16
8
16
24
32
40
48
56
Uout [V]
Iout [A]
@ 3 x 400V supply
@ 3 x 500V supply
2 4 6 8 10 12 14 16
4
8
12
16
20
24
28
Uout [V]
Iout [A]
Hiccup mode
@ 3 x 400V supply
@ 3 x 500V supply
8 16 24 32 40 48 56 64
4
8
12
16
20
24
28
Uout in V
72 80 Iout in A
Hiccup mode
after 2-5 s overload
U/I
@ 3 x 400 V supply
2 4 6 8 10 12 14 16
8
16
24
32
40
48
56
Uout [V]
Iout [A]
@ 3 x 400V supply
@ 3 x 500V supply
Hiccup mode
4 8 12 16 20 24 28 32
4
8
12
16
20
24
28
Uout [V]
Iout [A]
@ 3 x 400V supply
@ 3 x 500V supply
1 2 3 4 5 6 7 8
8
16
24
32
40
48
56
Uout [V]
Iout [A]
Hiccup mode
@ 3 x 400V supply
@ 3 x 500V supply
4 8 12 16 20 24 28 32
8
16
24
32
40
48
56
Uout in V
36 40 Iout in A
Hiccup mode
after 2-5 s overload
U/I
@ 3 x 400 V supply
2C
DC
27
2 0
21
F0
00
9
2C
DC
27
2 0
22
F0
00
9
89 3,5‘‘
131
5,1
6‘‘
124
4,8
8‘‘
2C
DC
27
2 0
23
F0
00
9
150 5,91‘‘
131
5,1
6‘‘
124
4,8
8‘‘
2C
DC
27
2 0
24
F0
00
9131
5.1
6‘‘
275.8 10.86‘‘
124
4.8
8‘‘
Technical diagrams, dimensions in mm
3
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/40
CP-T range
Technical diagrams
CP-T 24/40.0, CP-T 48/20.0CP-T 24/20.0, CP-T 48/10.0
CP-T 24/5.0, CP-T 24/10.0, CP-T 48/5.0
Temperature curve at rated load
2C
DC
27
2 0
26
F0
21
1
2C
DC
27
2 0
30
F0
21
1
2C
DC
27
2 0
25
F0
21
1
-40 60 70
10
203040
50
6070
8090
100
Pout [%]
Ta [°C]-30 60 70
10
203040
50
6070
8090
100
Pout [%]
Ta [°C]
-40 60 70
10
203040
50
6070
8090
100
Pout [%]
Ta [°C]
3
3/41 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
CP-S and CP-C
Product group picture
3
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/42
CP-S and CP-C
Table of contents
CP-S and CP-C range
Product group picture 3/41
Table of contents 3/42
Benefits and advantages 3/43
Operating control 3/44
Ordering details 3/45
Technical data 3/46
Technical diagrams, Dimensional drawings 3/50
3
3/43 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
CP-S and CP-C
Benefits and advantages
2C
DC
27
3 0
56
F0
00
4
2C
DC
27
3 0
46
F0
00
4
2C
DC
27
3 0
58
F0
00
4
2C
DC
27
3 0
57
F0
00
4
CharacteristicsCP-S and CP-C range – Output current 5 A, 10 A and 20 A
– Integrated power reserve of up to 50 %
– 5 A and 10 A devices with pluggable connecting terminals
– Approvals / marks
(depending on device, partly pending)
– A, H, R, K, / a, b
CP-S range – 10 A and 20 A device with front-face selector switch to
adjust rated input voltage range:
110-120 V AC or 220-240 V AC
– Output voltage fixed at 24 V DC
– Parallel operation for redundancy
CP-C range – Wide range input 110-240 V AC (85-264 V AC, 100-350 V DC)
– Output voltage adjustable within a range of 22-28 V DC
– Parallel operation for increased capacity and redundancy
– Power factor correction (PFC) acc. to EN 61000-3-2
– Function module pluggable onto the front side
Messaging module CP-C MM: – LED for status indication
– Relay outputs "Input OK" and "Output OK"
– REMOTE ON/OFF function to switch on and off the
power supply externally
– Output voltage monitoring is only possible in decoupled
parallel operation
Integrated power reserveThe new CP-S and CP-C range power supplies feature an in-
tegrated power reserve of up to 50 %. No oversized electricity
supply is needed, especially under heavy load conditions.
Pluggable connecting terminalsExtended flexibility in operation due to pluggable connecting
terminals (this feature is not offered on all devices).
Adjustable output voltageThe CP-C range types feature a continuously adjustable
output voltage from 22 to 28 V. Thus, they can be optimally
adapted to the application, e.g. compensating the voltage
drop caused by long line length.
Pluggable function modulesThe CP-C range power supplies can be equipped with plug-
gable modules to add additional functions (e.g. messaging
module). Thus, the power supplies can be ideally adapted to
the relevant application.
Benefits
1
1
2
2
3
3
4
4
3
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/44
CP-S and CP-C
Operating control
4
4
1
1
2
2
3
3
5
1 OUTPUT L+, L-: terminals - output
2 Indication of operational states OUTPUT OK: green LED - output voltage OK
3 OUTPUT Adj.: rotary potentiometer - adjustment of output voltage
4 Circuit diagram
5 INPUT L, N, PE: terminals - input
1 OUTPUT L+, L-: terminals - output
2 Indication of operational states OUTPUT OK: green LED - output voltage OK
3 Circuit diagram
4 INPUT L, N, PE: terminals - input
3
3/45 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
CP-S and CP-C
Ordering details
Description
The power supply units in the CP-S and CP-C range are ABB’s high-end solutions. Designed
with an integrated 50 % power reserve and an efficiency of approximately 89 % these are the
perfect products for all complex, highly reliable applications. All the devices cover the U-I out-
put characteristic and are built with thermal protection which switches off in case of overheat-
ing. In particular, the devices of the CP-C range feature a much broader functionality, including
active power factor correction and pluggable function modules.
These products are designed to trip MCB‘s in the 24 V DC output circuit. Coordination tables
are available.
Ordering details - CP-SInput voltage range Rated output
voltage / currentType Order code Price
1 pce
Weight(1 pce)kg (lb)
85-264 V AC / 110-350 V DC 24 V DC / 5 A CP-S 24/5.0 1SVR427014R00000.96 (2.11)
85-132 V AC, 184-264 V AC / 220-350 V DC
24 V DC / 10 A CP-S 24/10.0 1SVR427015R01001.07 (2.35)
85-132 V AC, 184-264 V AC / 220-350 V DC
24 V DC / 20 A CP-S 24/20.0 1SVR427016R01002.83 (6.23)
Ordering details - CP-CInput voltage range Rated output
voltage / currentType Order code Price
1 pce
Weight(1 pce)kg (lb)
85-264 V AC / 110-350 V DC 24 V DC / 5 A CP-C 24/5.0 1SVR427024R00000.96 (2.11)
85-264 V AC / 110-350 V DC 24 V DC / 10 A CP-C 24/10.0 1SVR427025R00001.34 (2.95)
85-264 V AC / 110-350 V DC 24 V DC / 20 A CP-C 24/20.0 1SVR427026R00003.15 (6.94)
2C
DC
27
1 0
61
F0
00
4
2C
DC
27
1 0
65
F0
00
4
2C
DC
27
1 0
63
F0
00
4
CP-S 24/5.0
CP-C 24/10.0
CP-S 24/20.0
Description Type Order code Price
1 pce
Weight(1 pce)kg (lb)
Messaging module for CP-C range power supplies CP-C MM 1SVR427081R00000.065 (0.14)
3
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/46
CP-S and CP-C
Technical data
Data at Ta = 25 °C, U
in = 230 V AC and rated values, unless otherwise indicated
Type CP-C 24/5.0
CP-S 24/5.0
CP-C 24/10.0
CP-S 24/10.0
CP-C 24/20.0
CP-S 24/20.0
Input circuit - supply circuit L, NRated input voltage U
inCP-C 110-240 V AC
CP-S switch position 115 110-240 V AC 110-120 V AC
switch position 230 220-240 V AC
Input voltage range CP-C 85-264 V AC / 100-350 V DC 1)
CP-S switch position 115 85-264 V AC / 100-350 V DC 1)
85-132 V AC
switch position 230 184-264 V AC / 220-350 V DC 1)
Frequency range AC 47-63 Hz
Typical input current CP-S and CP-C at 110-240 V AC 2.2-1.2 A 2.6-1.2 A 5.5-2.5 A
CP-S at 110-120 V AC - 4.2-4.0 A 9.0-8.0 A
CP-S at 220-240 V AC - 2.4-2.2 A 4.5-4.0 A
Typ. power consumption 135 W 269 W 538 W
Inrush current limiting / I2t ( cold start) CP-C < 23 A / approx. 0.9 A2s
< 33 A / approx. 0.2 A2s < 40 A / approx. 1.9 A2s
CP-S < 40 A / approx. 1.8 A2s < 70 A / approx. 8 A2s
Power failure buffering time min. 100 ms min. 40 ms min. 40 ms
Transient overvoltage protection varistors
Internal input fuse (apparatus protection, not accessible) 4 A (slow-acting) 6.3 A (slow-acting) 12 A (fast-acting)
Power factor correction (PFC) CP-C yes, active
CP-S no
Indication of operational statesOutput voltage OUTPUT OK: green LED V: output voltage OK
Output circuit L+, L+, L-, L- : short-circuit, no-load and overload proofRated output voltage 24 V DC
Tolerance of the output voltage CP-C ±1 %
CP-S -1...+5 %
Adjustment range of the output voltage
CP-C 22-28 V DC, default setting 24 V ±0.5 %
CP-S fixed
Rated output power 120 W 240 W 480 W
Rated output current Ta � 60 °C 5 A 10 A 20 A
Peak output current (power reserve) Ta � 40 °C typ. � 7.25 A typ. � 12.25 A typ. � 22.5 A
Derating 60 °C < Ta � 70 °C 2.5 % per Kelvin temperature increase
Deviation with CP-C load change statical 10-90 % typ. < ±0.05 %
CP-S load change statical 10-90 % typ. < ±0.1 %
load change dynamical 10-90 % typ. < ±3 %
change of the input voltage of ±10 % typ. < ±0.05 %
Control time typ. < 1 ms
Starting time after applying supply voltage
CP-C < 200 ms < 200 ms typ. < 200 ms
CP-S < 250 ms typ. < 300 ms
Rise time 10-90 % CP-C typ. < 30 ms typ. < 4 ms typ. < 12 ms
CP-S typ. < 5 ms typ. < 15 ms
Residual ripple and switching peaks BW = 20 MHz typ. < 50 mVPP
Parallel connection yes, up to 5 devices, to enable redundancy and to increasepower, current not symmetrical (CP-S only redundancy)
Series connection yes, to increase voltage, for decoupling refer to the application manual
Resistance to reverse feed approx. 35 V DC
Output circuit - No-load, overload and short-circuit behaviour see also U/I- and I/T-characteristic curvesCharacteristic curve of output U/I characteristic curve with power reserve
Current limiting at short circuit approx. 11 A approx. 19 A approx. 25 A
Short-circuit protection continuous short-circuit stability
Overload protection thermal protection
Starting of capacitive loads unlimited
General dataPower dissipation typ. < 15 W typ. < 29 W typ. < 58 W
Efficiency typ. 89 %
Discharge current for PE < 3.5 mA
MTBF CP-C 500.000 h
CP-S 350.000 h
Dimensions (W x H x D) 56.5 (60 2)) x 130 x 135.5 mm (2.22 (2.36 2)) x 5.12 x 5.35 in)
90 (93.5 2)) x 130 x 135.5 mm (3.54 (3.68 2)) x 5.12 x 5.35 in)
200 (203.5 2)) x 130 x 135.5 mm (7.87 (8.01 2)) x 5.12 x 5.35 in)
Weight CP-C approx. 0.96 kg (2.12 lb) approx. 1.34 kg (2.95 lb) approx. 3.15 kg (6.94 lb)
CP-S approx. 1.07 kg (2.36 lb) approx. 2.83 kg (6.23 lb)
Minimum distance to other units horizontal / vertical 10 mm / 80 mm (0.39 in / 3.15 in)
Degree of protection housing / terminals IP20 / IP20
Material of housing housing shell / cover aluminium / zinc-coated sheet steel
Protection class (EN 61140) I
Mounting DIN rail (IEC/EN 60715), snap-on mounting
Mounting position horizontal
3
3/47 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
CP-S and CP-C
Technical data
Data at Ta = 25 °C, U
in = 230 V AC and rated values, unless otherwise indicated
Type CP-C 24/5.0
CP-S 24/5.0
CP-C 24/10.0
CP-S 24/10.0
CP-C 24/20.0
CP-S 24/20.0
Electrical connection - Input circuit 3) 3) -
Wire size fine-strand with wire end ferrule 0.2-2.5 mm2 (24-14 AWG) 2.5-10 mm2 (14-8 AWG)
fine-strand without wire end ferrule 0.5-10 mm2 (20-8 AWG)
rigid 0.5-16 mm2 (20-6 AWG)
Stripping length 7 mm (0.28 in) 12 mm (0.47 in)
Tightening torque 0.4 Nm 1.2-1.5 Nm
Electrical connection - Output circuit 3) 3) -Wire size fine-strand with wire end ferrule 0.12-2.5 mm2 (26-14 AWG) 2.5-10 mm2 (14-8 AWG)
fine-strand without wire end ferrule 0.5-10 mm2 (20-8 AWG)
rigid 0.5-16 mm2 (20-6 AWG)
Stripping length 8 mm (0.31 in) 12 mm (0,47 in)
Tightening torque 0.4 Nm 1.2-1.5 Nm
Environmental dataAmbient temperature range operation -25...+70 °C
rated load 0...+60 °C (without derating)
storage -40...+85 °C
Damp heat (IEC/EN 60068-2-3) 93 % at +40 °C, no condensation
Climatic category (IEC/EN 60721) 3K3
Vibration (IEC/EN 60068-2-6)
Shock (IEC/EN 60068-2-27)
Isolation dataRated insulation voltage U
i between all isolated circuits
(IEC/EN 60950-1; EN 50178)input / output 300 V
input / PE 300 V
output / PE 50 V
Rated impulse withstand voltage Uimp
between all isolated circuits (IEC/EN 60950-1; EN 50178)
input / output 4 kV; 1.2/50 μs
input / PE 2.5 kV; 1.2/50 μs
output / PE 500 V; 1.2/50 μs
Power-frequency withstand voltage test (test voltage) (routine test / type test)
input / output 1.5 kV AC / 3.0 kV AC
input / PE 1.5 kV AC / 3.0 kV AC
output / PE 500 V DC / 500 V DC
Pollution degree (IEC/EN 60950-1; EN 50178) 2
Overvoltage category (IEC/EN 60950-1; EN 50178) II
StandardsProduct standard IEC/EN 61204
Low Voltage Directive 2006/95/EC
EMC Directive 2004/108/EC
Electrical safety EN 50178, EN 60950, UL 60950, UL 508
Protective low voltage SELV (EN 60950)
Electromagnetic compatibilityInterference immunity to IEC/EN 61000-6-2
electrostatic discharge IEC/EN 61000-4-2 Level 4 (8 kV / 15 kV)
radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 Level 3 (10 V/m)
electrical fast transient / burst IEC/EN 61000-4-4 Level 4 (4 kV)
surge IEC/EN 61000-4-5 Level 4 (2 kV symmetrical, level 3 - 3 kV asymmetrical)
conducted disturbances, induced by radio-frequency fields
IEC/EN 61000-4-6 Level 3 (10 V)
Interference emission IEC/EN 61000-6-3
high-frequency radiated IEC/CISPR 22; EN 55022 Class B
high-frequency conducted IEC/CISPR 22; EN 55022 Class B
1) at U > 264 V use additionally an appropriate external fuse2) with lateral screw3) pluggable connecting terminals, actuate only when power is off
„Approvals and marks“ on page 3/4.
3
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/48
CP-S and CP-C
Technical data
Data at Ta = 25 °C, U
in = 230 V AC and rated values, unless otherwise indicated
Type CP-C MM
Input circuit - Supply circuit
Rated input voltage Uin
110-240 V AC / 100-350 V DC
Input voltage range 70-264 V AC / 80-350 V DC
Power consumption 2.5 VA / 1.5 W
Input circuit - Control circuit
Kind of triggering volt-free triggering
Control input, control function Remote OFF remote off
Threshold "Switching-off power supply unit" R � 1 k�
Threshold "Switching-on power supply unit" R � 10 k�
Input current typ. 1 mA (200 mA for 200 μs)
Maximum cable length to the control input 25 m - 100 pF/m
Measuring circuit - INPUT powered by the input circuit of the power supply unit
Monitoring function undervoltage monitoring of input voltage of the power supply unit
Thresholds 85 V AC / 90 V DC
Hysteresis, related to the threshold value AC: typ. -8 % / DC -30 %
Accuracy, tolerance -5 % at AC and DC
Maximum measuring cycle typ. < 50 ms
Measuring circuit - OUTPUT powered by the output circuit of the power supply unit
Monitoring function undervoltage monitoring of output voltage of the power supply unit
Thresholds 20 V DC
Hysteresis, related to the threshold value typ. 5 %
Accuracy, tolerance ±1 %
Maximum measuring cycle typ. < 10 ms
Indication of operational states
Remote off REMOTE OFF: green LED V: „REMOTE OFF“ input R � 1k�
Status of power supply input Input OK: green LED V: relay „INPUT OK“ energized
Status of power supply output OUTPUT OK: green LED V: relay „OUTPUT OK“ energized
Output circuits 11-12/14, 21-22/24
Kind of output relays, 2 x 1 c/o contacts
Operating principle closed-circuit principle
Contact material AgNi
Rated voltage (VDE 0110, IEC/EN 60947-1) 250 V
Minimum switching voltage / Minimum switching current 24 V / 10 mA
Maximum switching voltage / Maximum switching current 250 V / 1 A
Rated operating current Ie (IEC/EN 60947-1) AC-12 (resistive) at 230 V 1 A
AC-15 (inductive) at 230 V 1 A
DC-12 (resistive) at 24 V 1 A
DC-13 (inductive) at 24 V 1 A
Mechanical lifetime 30 x 106 switching cycles
Electrical lifetime 0.1 x 106 switching cycles
Short circuit proof, maximum fuse rating
n/c contact 2 A, gL
n/o contact 2 A, gL
General data
Duty time 100 %
Dimensions (W x H x D, when mounted) 56.5 x 54 x 24 mm (2.22 x 2.13 x 0.94 in)
Weight 0.065 kg (0.14 lb)
Degree of protection housing / terminals IP20 / IP20
Material of housing Plastic
Protection class (EN 61140) II
Mounting snap-on mounting, without any tool
Mounting position plugged onto the power supply unit
Electrical connection
Wire size fine-strand with wire end ferrule0.2-2.5 mm2 (24-14 AWG)
fine-strand without wire end ferrule
rigid 0.2-4 mm2 (24-12 AWG)
Stripping length 7.5 mm (0.3 inch)
Tightening torque 0.4-0.6 Nm
3
3/49 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
CP-S and CP-C
Technical data
Data at Ta = 25 °C, U
in = 230 V AC and rated values, unless otherwise indicated
Type CP-C MM
Environmental data
Ambient temperature range operation -25...+70 °C
storage -40...+85 °C
Damp heat (IEC/EN 60068-2-3) 93 % at +40 °C, no condensation
Climatic category (IEC/EN 60721) 3K3
Vibration (IEC/EN 60068-2-6)
Shock (IEC/EN 60068-2-27)
Isolation data
Rated insulation voltage Ui (IEC/EN 60974-1, EN 50178, VDE 0160) 250 V
Protective separation (EN 50178, EN 60950) supply / measuring circuits / relay outputs
yes
Rated impulse withstand voltage Uimp
between all isolated circuits (IEC 664, VDE 0110)
4 kV; 1.2/50 μs
Test voltage between all circuits (type test) 2.5 kV AC
Pollution degree (EN 60950) 2
Overvoltage category (EN 60950) II
Standards
Product standard IEC/EN 61204
Low Voltage Directive 2006/95/EC
EMC Directive 2004/108/EC
Electrical safety EN 50178, EN 60950, UL 60950, UL 508
Elektromagnetic compatibility
Interference immunity to IEC/EN 61000-6-2
electrostatic discharge IEC/EN 61000-4-2 Level 3 and 4 (6 kV / 8 kV)
radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 Level 3 (10 V/m)
electrical fast transient / burst IEC/EN 61000-4-4 Level 4 and 2 (4 kV power input / 1 kV control input)
surge IEC/EN 61000-4-5 Level 3 and 2 (4 kV symmetrical power input / 1 kV control input)
conducted disturbances, induced by radio-frequency fields
IEC/EN 61000-4-6Level (10 V)
Interference emission IEC/EN 61000-6-3
high-frequency radiated IEC/CISPR 22; EN 55022 Class B
high-frequency conducted IEC/CISPR 22; EN 55022 Class B
„Approvals and marks“ on page 3/4.
3
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/50
CP-S and CP-C
Technical diagrams, Dimensional drawings
Uout [V]
Iout [A]
2C
DC
27
2 0
03
F0
b0
4
Uout [V]
Iout [A]
2C
DC
27
2 0
04
F0
b0
4
Uout [V]
Iout [A]
2C
DC
27
2 0
05
F0
b0
4
CP-S 24/5.0 CP-S 24/5.0, CP-C 24/5.0CP-C 24/5.0
CP-S 24/10.0 CP-S 24/10.0, CP-C 24/10.0CP-C 24/10.0
CP-S 24/20.0 CP-S 24/20.0, CP-C 24/20.0CP-C 24/20.0
Uout [V]
Iout [A]
2C
DC
27
2 0
26
F0
b0
4
Uout [V]
Iout [A]
2C
DC
27
2 0
27
F0
b0
4
Uout [V]
Iout [A]
2C
DC
272 0
28 F
0b
04
144,5 [5.69”] 60,0 [2.36”]
137,0 [5.39”]
13
0,0
[5
.12
”]
13
0,0
[5
.12
”]
56,5 [2.22”]
93,5 [3.68”]
90,0 [3.54”]
203,5 [8.01”]
200,0 [7.87”]
135,5 [5.33”]
13
0,0
[5
.12
”]
2CD
C 2
72 0
15 F
0b07
CP-S 24/5.0 CP-S 24/10.0 CP-S 24/20.0 CP-C 24/5.0 CP-C 24/10.0 CP-C 24/20.0 CP-A RU
Technical diagrams
Output curve at 25 °C Temperature curve at Uout = 24 V DCOutput curve at 25 °C
Iout [A]
Ta [°C]
2C
DC
27
2 0
75
F0
20
4
Iout [A]
Ta [°C]
2C
DC
272 0
06 F
0204
Iout [A]
Ta [°C]
2C
DC
27
2 0
88
F0
20
4
Dimensional drawings dimensions in mm
CP-C MM
54 [
2.13
”]
56,5 [2.22”]24 [0
.94”]
2C
DC
272 0
16 F
0b
07
3
3/51 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Redundancy units
Ordering details
Ordering details
Description suitable for decoupling of two CP-24 V DC power supply units or suitable for decoupling of CP-E power supply units
Type Order code Price
1 pce
Weight(1 pce)kg (lb)
2 inputs each up to 20 A and 1 output up to 40 A
� 40 V and � 5 A CP-A RU 1SVR427071R00000.89 (1.96)
Control module for CP-A RU redundancy units
- CP-A CM 1SVR427075R00000.063 (0.14)
2 inputs each up to 2.5 A and 1 output up to 5 A
� 35 V and < 5 A CP-RUD 1SVR423418R90000.15 (0.33)
2C
DC
27
1 0
03
F0
00
5
CP-A RU + CP-A CM
CP-A RU
CP-RUD
CP-D RU
2C
DC
27
1 0
10
F0
00
6
2C
DC
27
1 0
06
F0
00
32
CD
C 2
71
01
0 F
00
06
Ordering details - CP-D RU for decoupling of two CP-D power supply units
Input voltage range
Rated input current
Rated output voltage / current
Type Order code Price Weight(1 pce)kg (lb)
9-35 V DC 2 x 5 A24 V DC / 1 x 10 A
CP-D RU 1SVR427049R00000.075 (0.165)
3
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/52
Redundancy units
Technical data
TypeCP-A RU
CP-A RU
in combination with CP-A CMInput circuit - Supply circuit (+/ -, +/ -)Rated input voltage U
in24 V DC
Input voltage range per channel 10-28 V DC 13-28 V DC
Rated input current Iin per channel 1-20 A
Maximum input current per channel 30 A for 300 s
Transient overvoltage protection yes
Output circuit (++/--)Rated output voltage U
out24 V DC
Voltage drop typ. 0.6 V, max. 0.9 V
Rated output current Iout
1-40 A
Output ratings per channel Ta = 60 °C 10-28 V DC / 40 A 13-28 V DC / 40 A
Ta = 70 °C 10-28 V DC / 30 A 13-28 V DC / 30 A
Derating 60 °C < Ta � 70 °C 2.5 % per Kelvin temperature increase
Peak output current 60 A for 300 s
Resistance to reverse feed < 40 V
General dataDimensions (W x H x D) 56.5 (60 1)) x 130 x 135.5 mm; (2.22 (2.36 1)) x 5.12 x 5.35 in)
Weight 0.89 kg (1.96 lb)
Minimum distance to other units horizontal / vertical 10 mm / 50 mm (0.39 in / 1.97 in)
Degree of protection housing / terminals IP20 / IP20
Material of housing housing shell / cover aluminium / zinc-coated sheet steel
Protection class III 2)
Mounting DIN rail (IEC/EN 60715)
Mounting position horizontal
Electrical connection - Input circuit / Output circuitWire size fine-strand with wire end ferrule 2.5-10 mm2 (14-8 AWG)
fine-strand without wire end ferrule 0.5-10 mm2 (20-8 AWG)
rigid 0.5-16 mm2 (20-6 AWG)
Stripping length 12 mm (0.47 in)
Tightening torque 1.2-1.5 Nm
Environmental dataAmbient temperature range operation -25...+70 °C
rated load -25...+60 °C (without derating)
storage -40...+85 °C
Damp heat (IEC/EN 60068-2-3) 93 % at 40 °C, no condensation
Climatic category (IEC/EN 60721) 3K3
Vibration (IEC/EN 60068-2-6)
Shock (IEC/EN 60068-2-27)
Isolation dataInsulation voltage between input / output / housing 500 V AC (routine test)
Pollution degree (EN 50178) 2
StandardsProduct standard IEC/EN 61204
Low Voltage Directive 2006/95/EC
EMC Directive 2004/108/EC
Electrical safety EN 50178, EN 60950, UL 60950, UL 508
Electromagnetic compatibilityInterference immunity to IEC/EN 61000-6-2
electrostatic discharge IEC/EN 61000-4-2 Level 3 (air discharge ±8 kV, contact discharge ±6 kV)
radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 Level 3 (10 V/m)
electrical fast transient / burst IEC/EN 61000-4-4 Level 3 (±2 kV)
surge IEC/EN 61000-4-5 Level 1 (±0.5 kV)
conducted disturbances, induced by radio-frequency fields
IEC/EN 61000-4-6 Level 3 (10 V)
Interference emission IEC/EN 61000-6-3
high-frequency radiated IEC/CISPR 22 / EN 55022 Class B
high-frequency conducted IEC/CISPR 22 / EN 55022 Class B
1) incl. lateral screw2) This device is designed for connection to a safety extra-low voltage source. If no safety extra-low voltage is used at the input side, the lateral screw can be used for grounding
of the housing (protection class I).
„Approvals and marks“ on page 3/4.
3
3/53 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Type CP-A CMInput circuit - Supply circuitRated input voltage U
in24 V DC
Input voltage range 13-28 V DC
Rated input current at rated sense load and 24 V DC 120 mA
Power consumption at 24 V DC approx. 1 W
Measuring circuit 11-12/14, 21-22/24Monitoring function undervoltage monitoring
Measuring voltage rated operational voltage
Thresholds 14-28 V
Hysteresis, related to the threshold value fix: 3-5 %
Accuracy, tolerance 10 % of full-scale value
Maximum measuring cycle 6 ms
Indication of operational states
Status of input 1 IN 1: green LED : voltage at input 1 > than threshold 1 = no faults present
Status of input 2 IN 2: green LED : voltage at input 2 > than threshold 2 = no faults present
Output status OUT: green LED : UOUT
> 3 V = no faults present
Output circuit +, +, -Kind of output relays, 2 x 1 c/o contact
Contact material AgNi
Operating principle closed-circuit principle
Rated operational voltage Ue (IEC/EN 60947-1, VDE 0110) 250 V
Minimum switching voltage / Minimum switching current 24 V / 10 mA
Maximum switching voltage / Maximum switching current 250 V / 1 A
Rated operational current Ie
(IEC/EN 60947-5-1)AC-12 (resistive) at 230 V 1 A
AC-15 (inductive) at 230 V 1 A
DC-12 (resistive) at 24 V 1 A
DC-13 (inductive) at 24 V 1 A
Mechanical lifetime 30 x 106 switching cycles
Electrical lifetime 0.1 x 106 switching cycles
Rating according UL 508 General purpose (GP) 250 V AC 1 A
Maximum fuse rating to achieve short-circuit protection
n/o contact 2 A, gL
n/c contact 2 A, gL
Sense output (+, +, -) 1 SVR 427 075 R0000
Sense output voltage 13-28 V DC
Sense output current 0.1 A
Maximum fuse rating For applications acc. UL the sense output shall be provided with a listed DC fuse 3 A
General dataDuty time 100 %
Dimensions (W x H x D, when mounted) 56.5 x 54 x 24 mm (2.22 x 2.13 x 0.94 in)
Material of housing plastic
Weight 0.063 kg (0.14 lb)
Degree of protection housing / terminals IP20 / IP20
Protection class II
Mounting snap-on mounting, without any tool
Mounting position plugged onto the redundancy unit CP-A RU
Electrical conectionWire size fine-strand with wire end ferrule
0.2-2.5 mm2 (24-14 AWG)fine-strand without wire end ferrule
rigid 0.2-4 mm2 (24-12 AWG)
Stripping length 7.5 mm (0.3 in)
Tightening torque 0.4-0.6 Nm
Isolation dataRated insulation voltage U
i (IEC/EN 60947-1, EN 50178, VDE 0160) 250 V
Rated impulse withstand voltage Uimp
(type test) between all circuits (IEC 664, VDE 0110)
2.5 kV
Power-frequency withstand voltage test (routine test) between all circuits 1.2 kV AC
Protective separation (EN 50178) between input and output yes
Pollution degree 2
Overvoltage category II
Environmental dataAmbient temperature range operation -25...+70 °C
storage -40...+85 °C
Damp heat (IEC/EN 60068-2-3) 93 %at 40 °C, no condensation
Climatic category (IEC/EN 60721) 3K3
Vibration (IEC/EN 60068-2-6)
Shock (IEC/EN 60068-2-27)
Redundancy units
Technical data
3
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/54
Type CP-RUD
Input circuit - Supply circuit A: U1+/-U ; B: U2+/-URated input voltage U
in24 V DC
Input voltage range 5-35 V DC
Rated input current Iin per channel 0.5-2.5 A
Maximum input current per channel 10 A for 300 s
Transient overvoltage protection no
Output circuit L+, L+, L+, L-, L-, L-Rated output voltage U
out24 V DC
Voltage drop typ. 0.6 V, max. 0.7 V
Rated output current Iout
0.5-5 A
Peak output current 20 A for 150 s
Resistance to reverse feed < 35 V
General dataDimensions (W x H x D) 22.5 x 78 x 100 mm (0.89 x 3.07 x 4.02 in)
Weight 0.135 kg (0.30 lb)
Minimum distance to other units horizontal / vertical 10 mm / 10 mm (0.39 in / 0.39 in)
Degree of protection housing / terminals IP20 / IP20
Material of housing housing shell / cover plastic / plastic
Protection class -
Mounting DIN rail (IEC/EN 60715)
Mounting position horizontal
Electrical connection - Input circuit / Output circuit
Wire size fine-strand with wire end ferrule 2 x 0.75-2.5 mm2 (2 x 18-14 AWG)
fine-strand without wire end ferrule
rigid 2 x 0.5-4 mm2 (2 x 20-12 AWG)
Stripping length 7 mm (0.28 in)
Tightening torque 0.6-0.8 Nm
Environmental dataAmbient temperature range operation -20...+60 °C
rated load -20...+60 °C
storage -40...+85 °C
Damp heat (IEC/EN 60068-2-3) 93 % at 40 °C, no condensation
Climatic category (IEC/EN 60721) -
Vibration (IEC/EN 60068-2-6)
Shock (IEC/EN 60068-2-27)
Isolation dataInsulation voltage between input / output / housing -
Pollution degree (EN 50178) 2
StandardsProduct standard
Low Voltage Directive 2006/95/EC
EMC Directive 2004/108/EC
Electrical safety EN 50178
Electromagnetic compatibilityInterference immunity to IEC/EN 61000-6-2
electrostatic discharge IEC/EN 61000-4-2 Level 3 (air discharge ±8 kV, contact discharge ±6 kV)
radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 Level 3 (10 V/m)
electrical fast transient/burst IEC/EN 61000-4-4 Level 3 (�2 kV)
surge IEC/EN 61000-4-5 Level 1 (�0.5 kV)
conducted disturbances, induced by radio-frequency fields
IEC/EN 61000-4-6 Level 3 (10 V)
Interference emission IEC/EN 61000-6-3
high-frequency radiated IEC/CISPR 22 / EN 55022 Class B
high-frequency conducted IEC/CISPR 22 / EN 55022 Class B
1) incl. lateral screw2) This device is designed for connection to a safety extra-low voltage source. If no safety extra-low voltage is used at the input side, the lateral screw can be used for grounding
of the housing (protection class I).
Redundancy units
Technical data
3
3/55 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Type CP-D RU
Input circuit - Supply circuit IN 1 + + -, IN 2 + + -Rated input voltage U
in24 V DC
Input voltage range 9-35 V DC
Rated input current Iin per channel 5 A
Maximum input current per channel 10 A for 300 s
Transient overvoltage protection no
Output circuit OUT + + +, - - -Rated output voltage U
out24 V DC
Voltage drop typ. 0.5 V
Rated output current Iout
10 A
Resistance to reverse feed < 35 V
General dataMTBF on request
Duty time 100 %
Dimensions (W x H x D) product dimensions 35 x 91 x 56.5 mm (1.38 x 3.58 x 2.22 in)
packaging dimensions 134 x 94 x 48 mm (5.28 x 3.70 x 1.89 in)
Weight net weight 0.075 kg (0.165 lb)
gross weight 0.130 kg (0.286 lb)
Material of housing plastic
Mounting DIN rail, snap-on mounting without any tool
Mounting position horizontal
Minimum distance to other units horizontal / vertical 25 mm (0.98 in) / 25 mm (0.98 in)
Electrical connection - Input circuit / Output circuitWire size fine-strand with (out)wire end ferrule 0.2-2.5 mm2 (24-14 AWG)
rigid 0.2-2.5 mm2 (24-12 AWG)
Stripping length 7.0 mm (0.28 in)
Tightening torque 0.67 Nm (6 Ib.in)
Environmental dataAmbient temperature range operation -40...+70 °C
storage -40...+85 °C
Relative humidity RH at 40 °C 20-95 %, no condensation
Vibration (IEC/EN 60068-2-6) Mounting by rail: 10-500 Hz, 2 G, along X, Y, Z each axis, 60 min for each axis
Shock (IEC/EN 60068-2-27) 15 G, 11 ms, 3 axis, 6 faces, 3 times for each face
StandardsProduct standard IEC/EN 61204-3
Low Voltage Directive 2006/95/EC
EMC Directive 2004/108/EC
RoHS Directive 2011/65/EC
Electromagnetic compatibilityInterference immunity to EN 55024
electrostatic discharge IEC/EN 61000-4-2 Level 3, air discharge 8 kV, contact discharge 4 kV
radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 Level 3, 10 V/m
electrical fast transient/burst IEC/EN 61000-4-4 Level 3, 2 kV / 5 kHz
conducted disturbances, induced by radio-frequency fields IEC/EN 61000-4-6 Level 3, 10 V
Interference emission EN 55022
high-frequency radiated IEC/CISPR 22 / EN 55022 Class B
high-frequency conducted IEC/CISPR 22 / EN 55022 Class B
Redundancy units
Technical data
3
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/56
CP-A CM
54 [
2.13
”]
56,5 [2.22”]24 [0
.94”]
2C
DC
272 0
16 F
0b
07
2CD
C 2
52 1
88 F
0b05
100
102
109,5 [4.31“] 22,5
[.886“]
78
[3.0
7“]
[4.02“]
[3.94“]
CP-RUD
144,5 [5.69”] 60,0 [2.36”]
137,0 [5.39”]
13
0,0
[5
.12
”]
56,5 [2.22”]
135,5 [5.33”]
CP-A RU
2CD
C 2
72 0
15 F
0b07
2C
DC
27
20
33
F0
01
0
CP-D RU
67.0 2.64”
44.5 1.75”
32
.1 1
.26
”
57
.5
2.2
6”
49
.0
1.9
3”
91
.0 3
.58
”
35.0 1.38”
+ + + - - -O U T
+ - -+ + +IN1 IN2 IN2IN1
Redundancy units
Dimensional drawings
3
3/57 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
CP-ASI range
Product group picture
3
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/58
CP-ASI range
Table of contents
CP-ASI
Product group picture 3/57
Table of contents 3/58
Benefits and advantages 3/59
Ordering details 3/60
Technical data 3/61
Technical diagrams 3/63
Dimensional drawings 3/64
3
3/59 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
CP-ASI range
Benefits and advantages
Characterics – Rated output voltage 30.5 V DC for ASI-bus
– Rated output current up to 8.0 A
– High efficiency of up to 92 % 1)
– Infrared addressing mode 2)
– Low power dissipation and low heating
– Free convection cooling (no forced cooling with ventilators)
– Ambient temperature range during operation -10…70 °C 3)
– Open-circuit, overload and short-circuit stable
– Integrated input fuse
– Tool-free mounting on DIN rail as well as demounting
– LEDs for the indication of operational states
– Approval4): A /Mark: a1) Efficiency is depending on device2) Except CP-ASI/4.0 DC/DC3) Ambient temperature range CP-ASI/4.0 DC/DC -25…70°C4) Approvals are related to rated input voltage U
in
4
1
2
3
1 Output +, -, +, -, SHIELD: output terminals
2 Signalling contact 11-12: ground fault signalling terminals
3 Indication of operational states AS-I OK: green LED - output voltage OK
4 Configuration of operation mode Jumper5 Indication of operational states
IR ADDRESSING ON: red LED - infrared addressing mode active6 Test and reset button7 Indication of operational states
GROUND FAULT: red LED - ground fault detected8 Circuit diagram9 Input voltage selector Adjustment of input voltage10 Input L, N, PE: input terminals
5
6
7
8
9
10
3
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/60
CP-ASI range
Ordering details
Description
The CP-ASI power supply range is specifically designed with integrated data decoupling for
the supply of AS-Interface systems.
Up to 62 slaves (binary I/O devices) can be supplied with a single two-conductor cable.
The configurable IR addressing mode allows the easy assign of new ID addresses by means of
an external infrared programming unit.
Ordering detailsInput Voltage Range Rated
Output Voltage
Rated Output Current
Type Order code Price
1 pce
Weight(1 pce)kg (lb)
85-132 V AC, 184-264 V AC 30.5 V DC 2.8 A CP-ASI/2.8 1SVR427090R0280 0.495 (1.091)
85-132 V AC, 184-264 V AC 30.5 V DC 4.0 A CP-ASI/4.0 1SVR427090R0400 0.653 (1.440)
18-32.4 V DC 30.5 V DC 4.0 A CP-ASI/4.0 DC/DC 1SVR427095R0400 0.488 (1.076)
85-132 V AC, 184-264 V AC 30.5 V DC 8.0 A CP-ASI/8.0 1SVR427090R0800 0.897 (1.978)
2C
DC
27
1 0
02
S0
01
22
CD
C 2
71
00
3 S
00
12
2C
DC
27
1 0
04
S0
01
22
CD
C 2
71
00
5 S
00
12
CP-ASI/2.8
CP-ASI/4.0 DC/DC
CP-ASI/4.0
CP-ASI/8.0
3
3/61 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
CP-ASI range
Technical data
Data at Ta = 25 °C, U
in = 230 V AC and rated values, unless otherwise indicated
Type CP-ASI/2.8 CP-ASI/4.0 CP-ASI/8.0 CP-ASI/4.0 DC/DC
Input circuit - Supply circuit L, NRated input voltage U
in- 24 V DC
switch position 115 V 100-120 V AC -
switch position 230 V 220-240 V AC -
Input voltage range - 18.0-32.4 V DC
switch position 115 V 85-132 V AC -
switch position 230 V 184-264 V AC 184-264 V AC / 240-300 V DC
184-264 V AC -
Frequency range AC 47-63 Hz
Typical input current - 5.6 A
switch position 115 V 2.0 A 2.7 A 6.0 A -
switch position 230 V 0.9 A 1.3 A 2.8 A -
Allowed voltage between input and earth (ground) CP-ASI/4.0 DC/DC: max. 60 V DC / 42.4 V AC
Allowed input ripple voltage CP-ASI/4.0 DC/DC: max. 5 Vpp, 47 Hz - 40 kHz
Continuous input voltage with no damage to the DC/DC converter - max. 36.0 V DC
Turn-on voltage - typ. 17.5 V DC
Shut-down voltage - typ. 14.0 V DC
- typ. 35 V DC
Typical power consumption 94 W 135 W 261 W 132 W
Inrush current limiting / I²t (cold start) < 20 A (132 V AC) / approx. 1.5 A²/s
< 44.7 A (120 V AC) / approx. 3.7 A²/s
< 12 A (100 V AC) / approx. 1.0 A²/s
< 1.8 A / approx. 1.0 A²/s
< 38 A (264 V AC) / approx. 1.8 A²/s
< 49.3 A (132 V AC) / approx. 4.6 A²/s
< 14 A (120 V AC) / approx. 1.5 A²/s
-
- < 49.7 A (230 V AC) / approx. 2.5 A²/s
< 24 A (220 V AC) / approx. 1.4 A²/s
-
- < 57.5 A (264 V AC) / approx. 3.3 A²/s
< 27 A (240 V AC) / approx. 1.6 A²/s
-
Discharge current towards PE < 3.5 mA -Power failure buffering time - max. 0.5 ms
at 115 V AC min. 35 ms min. 40 ms min. 20 ms -at 230 V AC min. 40 ms min. 30 ms -
Transient overvoltage protection varistorsReverse input polarity protection CP-ASI/4.0 DC/DC: included, unit does not start at reversed polarity
Internal input fuse 8 A slow acting / 250 V AC
3.15 A slow acting / 250 V AC
8 A slow acting / 250 V AC
10 A slow acting
External fusing (not necessary, but recommended) circuit breaker with C characteristic min 6 A, or alternatively 10 A with B characteristic
-
Power factor correction (PFC) at 115 V AC 0.58 0.53 -at 230 V AC 0.53 0.48 -
Indication of operational statesOutput voltage AS-I OK LED greenIR addressing mode IR ADDRESSING ON LED red -Overload OVERLOAD LED red -
Output circuit +,-
Rated output voltage 30.5 V DC
Rated output power 85 W 122 W 244 W 122 W
Tolerance of the output voltage ± 3 %
Adjustment range of the output voltage - - -
Rated output current Ir
Ta � 60 °C 2.8 A 4.0 A 8.0 A 4.0 A
Derating of the output current 60 °C < Ta � 70 °C 2.5 %/°C
Signalling contact for ground fault CP-ASI/4.0: max. 25 V AC or 60 V DC, 0.5 AControl time < 2 msStarting time after applying the supply voltage max. 400 ms max. 700 ms max. 500 ms max. 1 s (typ. 650 ms)Rise time max. 100 ms -
at rated load - typ. 100 ms
with 5 mF - typ. 200 msResidual ripple BW = 500 kHz typ. < 50 mV
pp
Switching peaks BW = 20 MHz typ. < 100 mVpp
Output circuit - No-load, overload and short-circuit behaviourCharacteristic curve of output U/I characteristic curve Combined U/I
characteristic curve and hiccup mode
U/I characteristic curve
Short-circuit protection continuous short-circuit stability temporary short-circuit stability
continuous short-circuit stability
Short-circuit behaviour continuation with output power limiting - continuation with output power limiting
Current limiting at short circuit min / max 3.2 A / 4.6 A 4.2 A / 6.5 A 12 A / 25 A (max. 5 s) 5.0 A / 9.0 AOverload protection output power limiting temporary output
power limitingoutput power limiting
Overtemperature, overload and short circuit behaviour CP-ASI/8.0: at 8.4 A < Imax
< 12 A continuous current for 2-5 s, afterwards safety switch-off
Overtemperature protection CP-ASI/4.0 DC/DC: yes, automatic recovery after temperature went downNo-load protection continuous no-load stability
3
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/62
CP-ASI range
Technical data
Type CP-ASI/2.8 CP-ASI/4.0 CP-ASI/8.0 CP-ASI/4.0 DC/DCGeneral data
MTBF on request
Power dissipation typ. < 9.1 W (230 V AC, 2.8 A)
typ. < 13.5 W (230 V AC, 4.0 A)
typ. < 21.2 W (230 V AC, 8.0 A)
typ. < 12.7 W (24 V DC, 4.0 A)
Efficiency typ. 90.5 % typ. 90 % typ. 92.0 % typ. 90.5 %Duty time 100 %Dimensions (W x H x D) product dimensions 49 x 131 x 107 mm
(1.93 x 5.16 x 4.21 in)73 x 131 x 107 mm (2.87 x 5.16 x 4.21 in)
91 x 131 x 107 mm (3.58 x 5.16 x 4.21 in)
40 x 131 x 107 mm (1.58 x 5.16 x 4.21 in)
packaging dimensions 151 x 65 x 140 mm (5.94 x 2.56 x 5.51 in)
151 x 98 x 140 mm (5.94 x 3.86 x 5.51 in)
151 x 120 x 140 mm (5.94 x 4.72 x 5.51 in)
151 x 65 x 140 mm (5.94 x 2.56 x 5.51 in)
Weight net weight 0.495 kg (1.019 lb) 0.653 kg (1.440 lb) 0.897 kg (1.997 lb) 0.488 kg (1.076 lb)gross weight 0.568 kg (1.252 lb) 0.750 kg (1.653 lb) 1.015 kg (2.238 lb) 0.750 kg (1.287 lb)
Material of housing metalMounting DIN rail (IEC/EN 60715), snap-on mounting without any toolMounting position horizontalMinimum distance to other units horizontal / vertical 15 mm / 25 mm (0.59 / 0.99 in)Degree of protection housing / terminals IP20 / IP20Protection class I
Electrical connectionWire size fine-strand with wire end ferrule 0.5-4 mm² (20-12 AWG)
fine-strand without wire end ferrule 0.5-4 mm² (20-12 AWG)
rigid 0.5-6 mm² (20-10 AWG)
Stripping length 7 mm (0.28 in)
Tightening torque 0.8 Nm (7.08 lb.in)
Environmental dataAmbient temperature range operation -10...+70 °C -25...+70 °C
rated load -10...+60 °C -25...+60 °Cstorage -25...+85 °C -40...+85 °C
Vibration (sinusoidal) (IEC/EN 60068-2-6)
2-17.8 Hz, amplitude ± 1.6 mmsinusoidal (IEC/EN 60068-2-6) 17.8 Hz - 500 Hz, 2 g
random (IEC 60068-2-64) 2-800 Hz 0.5 s² (s³)Shock (half-sine) (IEC/EN 60068-2-27) 15 g (6 ms), 10 g (11 ms)
Isolation dataRated insulation voltage U
i
(IEC/EN 60950-1, EN 50178)input circuit / output circuit 300 V 50 V
input / PE 300 V 50 Voutput / PE 50 V
shield / output 50 Vshield / PE 50 V
Rated impulse withstand voltage Uimp
(EN 50178)
input / output 6 kV 1.2/50 μs 1.5 kV 1.2/50 μsinput / PE 4 kV 1.2/50 μs 0.8 kV 1.2/50 μs
output / PE 500 V 1.2/50 μs 500 V 1.2/50 μsPower-frequency withstand voltage test (test voltage) (routine test / type test)
input / output 2.5 kV AC / 3.0 kV AC 1.5 kV AC / 1.5 kV AC
input / PE 2.5 kV AC / 2.5 kV AC 1.5 kV AC / 1.5 kV AC
output / PE 500 V AC / 500 V ACPollution degree (IEC/EN 60950-1) 2Overvoltage category (UL/IEC/EN 60950-1) input II (IEC/EN 60950-1), III (EN 50178)
output II (IEC/EN 60950-1), II (EN 50178)
StandardsLow Voltage Directive 2006/95/ECEMC directive 2004/108/ECRoHS directive 2011/65/ECElectrical safety IEC/EN 60950-1Protective low voltage SELV (IEC/EN 60950-1), PELV
Electromagnetic compatibilityInterference immunity to IEC/EN 61000-6-2electrostatic discharge IEC/EN 61000-4-2 Level 4 (8 kV / 15 kV)
radiated, radio-frequency, electromagnetic field
IEC/EN 61000-4-3 Level 3 (10 V/m)
electrical fast transient/burst IEC/EN 61000-4-4 input circuit: Level 4 (4 kV) input circuit: Level 3 (2 kV)
output circuit: Level 3 (2 kV) output circuit: Level 2 (1 kV)
surge IEC/EN 61000-4-5 input circuit: L-L Level 3 (2 kV) / L-PE Level 4 (4 kV) input circuit: L-L Level 2 (1 kV) / L-PE Level 3 (2 kV)
output circuit: Level 1 (0.5 kV) output circuit: Level 1 (0.5 kV)
conducted disturbances, induced by radio-frequency fields
IEC/EN 61000-4-6 Level 3 (10 V, 150 kHz - 80 MHz) Level 3 (10 V, 150 kHz - 80 MHz)
voltage dips, short interruptions and voltag variations
IEC/EN 61000-4-11 Class 3
Interference emission IEC/EN 61000-6-3 IEC/EN 61000-6-4 IEC/EN 61000-6-3high-frequency radiated IEC/CISPR 22, EN 55022 Class Bhigh-frequency conducted IEC/CISPR 22, EN 55022 Class Blimits for harmonic current emissions IEC/EN 61000-3-2 Class A - -
3
3/63 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
CP-ASI range
Technical diagrams
12
16
20
24
28
32
8
4
00 1 2 3 4
Uout [V]
Iout [A]
15
20
25
30
35
10
5
00 1 2 3 4 5
Uout [V]
6 7 8 Iout [A]
15
20
25
30
35
10
5
00 1 2 3 4 5
Uout [V]
6 Iout [A]
15
20
25
30
35
10
5
00 2 4 6 8 10
Uout [V]
12 Iout [A]
-10 60 70 Ta [°C]
Iout [A]
2.8
2.1
-25 60 70 Ta [°C]
Iout [A]
4
3
-10 60 70 Ta [°C]
Iout [A]
4
3
-10 60 70 Ta [°C]
Iout [A]
8
6
Output behaviour
Output behaviour
Output behaviour
Output behaviour
Characteristic curve of temperature at rated load
Characteristic curve of temperature at rated load
Characteristic curve of temperature at rated load
Characteristic curve of temperature at rated load
CP-ASI 2.8
CP-ASI 4.0 DC/DC
CP-ASI 4.0
CP-ASI 8.0
Characteristic curve at Ta = 25 °C
2C
DC
27
2 0
07
F0
01
2
2C
DC
27
2 0
11
F0
01
22
CD
C 2
72
00
9 F
00
12
2C
DC
27
2 0
13
F0
01
2
2C
DC
27
2 0
06
F0
21
22
CD
C 2
72
01
0 F
02
12
2C
DC
27
2 0
08
F0
21
2
2C
DC
27
2 0
12
F0
21
2
3
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/64
CP-ASI range
Dimensional drawings
102 4.02”
49 1.93”
62 2
.44”
131
5.1
6”
5 0.20”
94 3.78”
62 2
.44”
102 4.02”
62 2
.44”
5 0.20”
94 3.78”
62 2
.44”
73 2.87”
131
5.
16”
102 4.02”
62 2
.44”
5 0.20”
94 3.78”
62 2
.44”
40 1.58”
131
5.
16”
102 4.02”
62 2
.44”
5 0.20”
94 3.78”
62 2
.44”
91 3.58”
131
5.
16”
CP-ASI 2.8
CP-ASI 4.0
CP-ASI 4.0 DC/DC
CP-ASI 8.0
2C
DC
27
2 0
14
F0
01
2
2C
DC
27
2 0
15
F0
01
2
2C
DC
27
2 0
16
F0
01
2
2C
DC
27
2 0
17
F0
01
2
Dimensions in mm/inch
3
3/65 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
CP-B range
Product group picture
3
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/66
CP-B range
Table of contents
CP-B
Product group picture 3/65
Table of contents 3/66
Benefits and advantages 3/67
Ordering details 3/68
Technical data 3/69
Technical data, Technical diagrams 3/70
Dimensional drawings 3/71
Technical data 3/72
3
3/67 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
1 Input terminals SHUT-DOWN+, SHUT-DOWN-: Input signal terminals
INPUT OK, BUFFER STATUS, FAILURE: Signalling contact – terminals
L+IN
, L-IN
: Input voltage terminals
2 Indication of operational states OPERATION: Buffer module in operation (standby or buffering)
INPUT OK: Input voltage applied
3 Output terminals L+
OUT, L-
OUT, L-
OUT: Output voltage terminals
CP-B range
Benefits and advantages
CP-B 24/3.0 CP-B 24/10.0 CP-B 24/20.0 CP-B EXT.2
Order code 1SVR427060R0300 1SVR427060R1000 1SVR427060R2000 1SVR427065R0000
Rated input voltage 24 V DC 24 V DC 24 V DC –
Rated current 3 A DC 10 A DC 20 A DC 3 A DC
Energy storage (min.) 1.000 Ws 10.000 Ws 8.000 Ws 2.000 Ws
Typical charging time at load current
100 % 65 s 134 s 135 s
0 % 56 s 82 s 62 sTypical buffering time1)
at load current
100 % 13 s 38 s 15 s
50 % 28 s 76 s 30 s
25 % 66 s 140 s 60 s
10 % 148 s 380 s 150 s1) buffering time ≈
Power supply systems have to be highly reliable in most areas of
energy management and automation technology.
Often batteries are used for supporting the supply system in
case of mains failures. Batteries have limited lifetimes depending
on environmental parameters and have to be maintained regu-
larly, which causes efforts and costs.
Using the latest ultra-capacitor technology, ABB offers an in-
novative and completely maintenance free new product for
buffering the 24 V DC supply in case of interrupted mains on the
primary side of the switch mode power supply.
The CP-B range is an ultra-capacitor buffer energy storage for
power supply units which ensures a short term uninterrupted
power supply system. In case of a power loss, the energy stored
in the capacitor guarantees that the load is continually provided
up to several hundred seconds depending on the load current.
Characteristics – 3 buffer modules for buffering 24 V DC:
CP-B 24/3.0 (3 A / 1 kWs1))
CP-B 24/10.0 (10 A / 10 kWs1))
CP-B 24/20.0 (20 A / 8 kWs1))
– CP-B 24/3.0 and CP-B 24/20.0 expandable
with additional extension module(s) CP-B EXT.2
(2 kWs1))
– LEDs for status indication
– Relay contacts for status messaging
– Very high backup times (e.g. with CP-B 24/10.0
up to 8 minutes at 1 A load current)
– Short charging times
– High efficiency, higher than 90%
– Wide temperature range
– DIN rail mountable, compact housing
Advantages in comparison to battery buffers:
– Maintenance free
– No deep discharge
– Temperature resistant
– A (UL508, CSA22.2 No 14), R approvals
1) internal energy buffer
energy storage x 0.9
current x output voltage
1
1
2
3
3
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/68
CP-B range
Ordering details
Description
Ultra capacitor based buffer units of the CP-B range offer highest reliability also in harsh
enivronment. Due to the ultra-cap based technology the units are maintenance free, there will
be no deep discharge and these products offer a very wide operational ambient temperature
range.
CP-B range buffer units are an excellent solution to avoid voltage drops, for example in solar
applications.
Ordering detailsRated input voltage Rated current Type Order code Price
1 pce
Weight(1 pce)kg (lb)
24 V DC
3 A DC CP-B 24/3.0 1SVR427060R0300 0.55 (1.21)
10 A DC CP-B 24/10.0 1SVR427060R1000 2.10 (4.63)
20 A DC CP-B 24/20.0 1SVR427060R2000 2.20 (4.85)
2C
DC
27
1 0
01
S0
01
02
CD
C 2
71
00
2 S
00
10
2C
DC
27
1 0
03
S0
01
0
CP-B 24/3.0
CP-B 24/10.0
CP-B 24/20.0
Ordering details - Extension unit for CP-B 24/3.0 and CP-B 24/20.0Rated voltage Voltage range Type Order code Price
1 pce
Weight(1 pce)kg (lb)
24 V DC 0-26.4 V DC CP-B EXT.2 1SVR427065R0000 1.00 (2.20)
CP
-B 2
4/10
.0
L+IN L-IN
L+OUT L-OUT
max. 20 A
CP
-C 2
4/20
.0
L N
L+ L-
max. 10 A
... ...
L+
L-
L+
L-
buffered unbuffered
load 1 load n load 1 load n
Example of application
3
3/69 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
CP-B range
Technical data
Type CP-B 24/3.0 CP-B 24/10.0 CP-B 24/20.0
Input circuit - Supply circuit L+IN L-IN
Rated input voltage Uin
24 V DC
Input voltage range 23.7-26.4 V DC 23.9-27 V DC 23.4-27.4 V DC
Minimum charging potential 23.7 V DC 23.9 V DC 23.4 V DC
Rated input current 3 A DC 10 A DC 20 A DC
Inrush current limiting 50 A / 1 ms 35 A / 2 ms 35 A / 2 ms
Transient overvoltage protection suppressor diode varistor / suppressor diode varistor / suppressor diode
Internal input fuse (apparatus protection, not accessible) 4 A slow acting 15 A (FK2) 30 A (FK2)
Internal fuse capacitors circuit (not accessible) 25 A (FK2)
Kind of input SHUT-DOWN - control input control input
rated voltage - 24 V DC 24 V DC
voltage range - 6-45 V DC 6-45 V DC
Output circuit L+OUT L-OUT L-OUT
Rated output power 69 W 240 W 480 W
Rated output voltage Uout 24 V DC
Output voltage (buffer mode) 23.0 V DC 23.2 V DC 23.2 V DC
Tolerance of the output voltage +2...-10 %
Rated output current Ir Ta m 60 °C 3 A DC 10 A DC 20 A DC
Peak output current (fully loaded capacitors required)
Ta m 60 °C 6 A DC (min. 1.5 s) 20 A DC (10 A power supply + 10 A CP-B, min. 1.5 s)
40 A DC (min. 1.5 s)
Control of limiting current - 10.3 A DC �0.1A -
Shut-down if limiting current is exceeded - after 1.5 s -
Short-circuit protection (only via external fuse) no continuous short-circuit stability
Internal output fuse (not accessible) - 15 A (FK2) -
Required external fuse 3.15 A slow acting 10 A slow acting 25 A slow acting
Current limiting at output circuit - 1.05...1.2 x Ir
-
Breaking capacity of output circuit t= 2.5 ms - 24 V DC, 10 A -
Power failure buffering time 1)load-dependent, min. 13 s at 100 % load
load-dependent, min. 38 s at 100 % load
load-dependent, min. 15 s at 100 % load
Overload protection thermal protection
Kind of output INPUT OK n/o contact
BUFFER STATUS - n/o contact
FAILURE - c/o contact
Contact material Ag + Au-clad
Minimum switching voltage / Minimum switching current 5 V DC / 1 mA
Maximum switching voltage / Maximum switching current 50 V AC / 1.0 A, 30 V DC / 0.5 A
Mechanical lifetime 5 x 106 switching cycles
Electrical lifetime 0.1 x 106 switching cycles
Maximum fuse rating to achieve short-circuit protection n/o or n/c contact 1.0 A AC / 0.5 A DC
General dataMaximum internal power consumption 7 W 20 W 40 W
Power consumption with unloaded output 0.75 W 3 W 1.6 W
Energy storage (min.) 1000 Ws 10000 Ws 8000 Ws
Typical charging time at load current 100 % 65 s 134 s 135 s
0 % 56 s 82 s 62 s
Typical buffering time at load current1) 100 % 13 s 38 s 15 s
50 % 28 s 76 s 30 s
25 % 66 s 140 s 60 s
10 % 148 s 380 s 150 s
Efficiency greater than 90 %
Dimensions (W x H x D) product dimensions 60 x 99 x 120 mm (2.36 x 3.90 x 4.72 in)
116 x 170 x 147 mm (4.57 x 6.69 x 5.79 in)
84 x 197 x 213 mm (3.31 x 7.76 x 8.39 in)
Weight net weight 0.55 kg (1.21 lb) 2.1 kg (4.63 lb) 2.2 kg (4.85 lb)
Material cover / housing shell steel sheet powdered
Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool
Mounting position horizontal
Minimum distance to other units horizontal not necessary
vertical 40 mm (1.58 in) 80 mm (3.15 in)
Pollution degree 2
Degree of protection housing / terminal IP20
Protection class (IEC/EN 61140) III SELV / PELV (condition: power supply fulfills class III)
Electrical connection - Input circuit / Output circuit pull spring terminals pull spring terminals pluggable screw type terminals
Wire size fine-strand with(out) wire end ferrule 0.08-1.0 mm² (28-18 AWG)
0.08-1.5 mm² (28-18 AWG)
0.2-4.0 mm² (24-12 AWG)
rigid 0.08-1.5 mm² (28-16 AWG)
0.08-4.0 mm² (28-16 AWG)
0.2-6.0 mm² (24-10 AWG)
Stripping length 6.0 mm (0.24 in) 7.0 mm (0.28 in)
3
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/70
CP-B range
Technical data, Technical diagrams
Type CP-B 24/3.0 CP-B 24/10.0 CP-B 24/20.0
Input circuit - Supply circuit L+IN L-IN
Signalling circuitWire size fine-strand with(out) wire end ferrule 0.08-1.0 mm² (28-18 AWG) 0.14-1.0 mm² (26-16 AWG)
rigid 0.08-1.5 mm² (28-16 AWG) 0.14-1.5 mm² (28-16 AWG)
Stripping length 6.0 mm (0.24 in) 7.0 mm (0.28 in)
Environmental dataAmbient temperature operation -40...+60 °C -20...+60 °C
storage -40...+60 °C -20...+60 °C
StandardsProduct standard EN 50178
Low Voltage Directive 2006/95/EC
EMC Directive 2004/108/EC
RoHS Directive 2011/65/EC
Electrical safety EN 50178, EN 60950, UL 508
Electromagnetic compatibilityInterference immunity to IEC/EN 61000-6-1, IEC/EN 61000-6-2
electrostatic discharge IEC/EN 61000-4-2 Level 3, 6 kV / 8 kV
radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 Level 3, 10 V/m (27-1000 MHz) / Level 2, 3 V/m (1400-2700 MHz)
electrical fast transient/burst IEC/EN 61000-4-4 Level 3, 2(1) kV / 5 kHz
surge IEC/EN 61000-4-5 Level 1, 0.5 kV
conducted disturbances, induced by radio-frequency fields
IEC/EN 61000-4-6 Level 3, 10 V (150 kHz-80 MHz)
voltage dips, short interruptions and voltage variations
IEC/EN 61000-4-11 buffered by ultra-capacitors
Interference emission EN 61000-6-3, EN 61000-6-4
high-frequency radiated DIN EN 55011 B/C1
high-frequency conducted DIN EN 55011 B/C1
„Approvals and marks“ on page 3/4.
1) buffering time ≈ energy storage x 0.9
load current x output voltage
CP-B 24/3.0 CP-B 24/20.0
CP-B 24/10.0
Technical diagramsOutput curve at Ta = 25 °C
Caracteristic curve of the temperature at rated load Capacitor's life span over temperature
Iout [A]
0 20 40 60-40Ta [°C]
1.5
3.0
Normal application (up to 50 % buffer mode, 5 chargingand discharging cycles in direct series)
Continuous charging and discharging in direct series.As this is not typical of a real application, this should be considered as theoretical indication
Iout [A]
0 20 40 60-40Ta [°C]
Normal application (up to 50 % buffer mode, 5 chargingand discharging cycles in direct series)
Continuous charging and discharging in direct series.As this is not typical of a real application, this should be considered as theoretical indication
5.0
7.5
10.0
Iout [A]
0 20 40 60-20
10
15
20
Ta [°C]
Normal application (up to 50 % buffer mode, 5 chargingand discharging cycles in direct series)
Continuous charging and discharging in direct series.As this is not typical of a real application, this should be considered as theoretical indication
3020100
10
20
30
40
50
60
60 7040 50
Temperature [°C]
Ye
ars
2C
DC
27
2 0
28
F0
21
0
2C
DC
27
2 0
30
F0
21
0
2C
DC
27
2 0
29
F0
21
0
2C
DC
27
2 0
31
F0
21
0
3
3/71 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
CP-B range
Dimensional drawings
Dimensions in mm and inches
CP-B 24/3.0
93 3
.66‘
‘
60 2.36‘‘ 112 4.41‘‘
119 4.69‘‘
120 4.72‘‘
99 3
.90‘‘
CP-B EXT.2CP-B 24/10.0
93 3
.66‘‘
99 3
.90‘‘
60 2.36‘‘ 112 4.41‘‘
119 4.69‘‘
120 4.72‘‘
163
6.4
2‘‘
116 4.57‘‘
170
6.6
9‘‘
138 5.43‘‘
147 5.79‘‘146 5.75‘‘
CP-B 24/20.0
193
7.6
0‘‘
196 7.72‘‘
188 7.40‘‘
213 8.39‘‘
84 3.31‘‘
197
7.7
6‘‘
2C
DC
27
2 0
37
F0
01
0
2C
DC
27
2 0
39
F0
01
02
CD
C 2
72
03
6 F
00
10
2C
DC
27
2 0
38
F0
01
0
3
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/72
CP-B range
Technical data
Data at Ta = 25 °C and rated values, unless otherwise indicated
Type CP-B EXT 2.0Extension circuit EXT+ EXT+ EXT- EXT-Rated voltage 24 V DC
Voltage range 0-26.4 V DC
Rated current 3 A DC
Internal input fuse (apparatus protection, not accessible) 4 A slow acting (PTC)
Short-circuit protection via internal 3 A fuse
Overload protection only in combination with CP-B 24/3.0 or CP-B 24/20.0
Indication of operational states
status information and fault messages of the buffer module apply
General dataPower consumption without load 0.5 W
Energy storage (min.) 2000 Ws
Dimensions (W x H x D) product dimensions 60 x 99 x 120 mm (2.36 x 3.90 x 4.72 in)
packaging dimensions 85 x 220 x 170 mm (3.35 x 8.66 x 6.69 in)
Weight net weight 1.00 kg (0.20 lb)
Material cover / housing shell steel sheet powdered
Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool
Mounting position horizontal
Minimum distance to other units horizontal not necessary
vertical 40 mm (1.58 in)
Pollution degree 2
Degree of protection housing / terminal IP20
Protection class (IEC/EN 61140) III SELV / PELV (condition: power supply fulfills class III)
Electrical connection - Extension circuit Wire size fine-strand with(out) wire end ferrule 0.08-1.0 mm² (28-18 AWG)
rigid 0.08-1.5 mm² (28-16 AWG)
Stripping length 6.0 mm (0.24 in)
Signalling circuit
Wire size fine-strand with(out) wire end ferrule 0.08-1.0 mm² (28-18 AWG)
rigid 0.08-1.5 mm² (28-16 AWG)
Stripping length 6.0 mm (0.24 in)
Environmental dataAmbient temperature operation -40...+60 °C
storage -40...+60 °C
Vibration, sinusoidal based on IEC/EN 60068-2-6 1.5 mm, 3-57.55 Hz; 2 g, 57.55-500 Hz, 10 cycles
Shock, half-sine based on IEC/EN 60068-2-27 15 g, 11 ms, 3 axes, 6 faces, 3 times for each face
StandardsProduct standard EN 50178
Low Voltage Directive 2006/95/EC
EMC Directive 2004/108/EC
RoHS Directive 2011/65/EC
Electrical safety EN 50178, EN 60950, UL 508
Electromagnetic compatibilityInterference immunity to IEC/EN 61000-6-1, IEC/EN 61000-6-2
electrostatic discharge IEC/EN 61000-4-2 Level 3, 6 kV / 8 kV
radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 Level 3, 10 V/m (27-1000 MHz) / Level 2, 3 V/m (1400-2700 MHz)
electrical fast transient/burst IEC/EN 61000-4-4 Level 3, 2(1) kV / 5 kHz
surge IEC/EN 61000-4-5 Level 1, 0.5 kV
conducted disturbances, induced by radio-frequency fields
IEC/EN 61000-4-6 Level 3, 10 V (150 kHz-80 MHz)
voltage dips, short interruptions and voltage variations IEC/EN 61000-4-11 buffered by ultra-capacitors
Interference emission EN 61000-6-3, EN 61000-6-4
high-frequency radiated DIN EN 55011 B/C1
high-frequency conducted DIN EN 55011 B/C1
„Approvals and marks“ on page 3/4.
3
3/73 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Electronic protection devices EPD24
Product group picture
3
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/74
Electronic protection devices EPD24
Table of contents
Electronic protection devices EPD24
Product group picture 3/73
Table of contents 3/74
Ordering details 3/75
Technical data 3/76
Technical information 3/78
Approvals, safety instructions 3/79
Installation guidelines 3/80
3
3/75 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Electronic protection devices EPD24
Ordering details
The protection devices EPD24 extend the ABB product range of Modular DIN rail components by
electronic overcurrent protection modules for selective protection of 24 V DC load circuits.
This protection is achieved by a combination of active electronic current limitation in the case of a
short circuit and an overload deactivation from 1.1 x In upwards.
If a fault occurs in a load circuit, the protection device EPD24 will detect this rapidly and reliably,
disable the power output transistor and hence interrupt the current flow in the defective circuit. The
maximum possible overcurrent is always limited to 1.3…1.8 times the selected rated current. An
activation of capacitive loads up to 20,000 μF is possible, deactivation only occurring in the case of
overloads or short circuits. Selective deactivation of the defective current circuit means undefined
error states and a complete system stop are prevented.
Features – Selective load protection, one electronic tripping characteristic.
– Active current limitation for safe connection of capacitive loads up to 20,000 μF and on
overload/short circuit.
– Current ratings 0.5 A...12 A.
– Reliable overload disconnection with 1.1 x IN
– Manual ON/OFF button
– Clear status and failure indication through LED and integrated auxiliary contact.
– Integral fail-safe element adjusted to current rating.
– Width per unit only 12.5 mm.
– Rail mounting
– Ease of wiring through busbar LINE+ and 0 V as well as signal bars.
– UL- and CSA-approvals allow international use of the devices.
Ordering detailsRatedcurrent IN A
bbn 40 16779 EAN Type Order code Price Pkg qty
Weight(1 pce)kg (lb)
0.5 829960 EPD24-TB-101-0.5A 2CDE601101R2905 40.065 (1.433)
1 829984 EPD24-TB-101-1A 2CDE601101R2001 40.065 (1.433)
2 830003 EPD24-TB-101-2A 2CDE601101R2002 40.065 (1.433)
3 830027 EPD24-TB-101-3A 2CDE601101R2003 40.065 (1.433)
4 830041 EPD24-TB-101-4A 2CDE601101R2004 40.065 (1.433)
6 830065 EPD24-TB-101-6A 2CDE601101R2006 40.065 (1.433)
8 830089 EPD24-TB-101-8A 2CDE601101R2008 40.065 (1.433)
10 830102 EPD24-TB-101-10A 2CDE601101R2010 40.065 (1.433)
12 830126 EPD24-TB-101-12A 2CDE601101R2012 40.065 (1.433)
Ordering details
Description bbn 40 16779 EAN
Type Order code Price Pkg qty
Weight(1 pce)kg (lb)
Busbars for LINE+ and 0 V, grey insulation, length 500 mm 1) 830140 EPD-BB500 2CDE605100R0500 10
0.2(0.441)
Signal Bars for aux. contacts, grey insulation, length 21 mm
830164 EPD-SB21 2CDE605200R0021 100.4 (0.882)
1) Max. load with one line entry Imax = 50 A (recommended: mid line entry)
Max. load with two line entries Imax = 63 A
2C
DC
05
1 0
01
S0
01
0
EPD24-TB-101-3A
3
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/76
Electronic protection devices EPD24
Technical data
LINE+ 1
14
13
2 LOAD+
0V 3
Wiring diagramm
EPD24-TB-101
without signal input
with signal output F
(Single signal, N/O)
Operating condition: 13-14 closed
Fault condition: 13-14 open
Operating data
Operating voltage UB
24 V DC (18...32 V)
Current rating IN
fixed current ratings: 0.5, 1, 2, 3, 4, 6, 8, 10, 12 A
Closed current I0
ON condition: typically 20...30 mA depending on signal output
Staus indication by means of Green:unit is ON load circuit / Power-MOSFET is switched on
Orange:in the event of overload or short circuit until electronic disconnection
Red: unit electronically disconnectedload circuit/Power-MOSFET OFFundervoltage (U
B < 8 V)
after switch-on till the end of the delay period
OFF: manually switched off or device is dead
potential-free auxiliary contact F
ON/OFF/ condition of switch
Load circuit
Load output Power-MOSFET switching output (high slide switch)
Overload disconnection typically 1.1 x IN (1.05...1.35 x I
N)
Short-circuit current IK active current limitation
Trip time see time/current characteristics
For electronic disconnection typically 3 s at ILoad
> 1.1 x IN
typically 100 ms...3 s at ILoad
> 1.8 x IN
(or 1.5 x IN/1.3 x I
N, )
Temperature disconnection internal temperature monitoring with electronic disconnection
Low voltage monitoring load output with hysteresis, no reset required: load »OFF« at U
B< 8 V
Starting delay tStart
typically 0.5 sec after every switch-on and after applying UB
Disconnection of load circuit
electronic disconnection
Free-wheeling circuit suitable external free-wheeling circuit to be used with inductive load
Several load outputs must not be connected in parallel
Signal output
Electrical data potential-free auxiliary contactmax. 30 V DC/0.5 A, min. 10 V DC/10 mA
ON condition LED green voltage UB applied, switch is in ON position
no overload, no short circuit
OFF condition LED off device switched off (switch is in OFF position)no voltage U
B applied
Fault condition LED orange overload condition > 1.1 x IN up to electronic disconnection
Fault condition LED red electronic disconnection upon overload or short circuitDevice switched off with control signal (switch is in ON position)
Aux. contact single signal, make contactcontact open, terminal 13-14
Fault signal output fault conditionsno operating voltage U
B
ON/OFF switch is in OFF positionred LED lighted (electronic disconnection)
3
3/77 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Electronic protection devices EPD24
Technical data
General data
Fail-Safe element backup fuse for EPD24 not required because of the integral redundant fail-safe element
Housing material moulded
Mounting symmetrical rail to EN 50022-35x7.5
Ambient temperature 0...+50 °C (without condensation, see EN 60204-1)
Storage temperature -20...+70 °C
Humidity 96 hrs/95 % RH/40 °C to IEC 60068-2-78, test Cab. climate class 3K3 to EN 60721
Vibration 3 g, test to IEC 60068-2-6 test Fc
Degree of protection housing: IP20 DIN 40050 terminals: IP20 DIN 40050
EMC (EMC directive, CE logo)
emission: EN 61000-6-3 susceptibility: EN 61000-6-2
Isolations coordination (IEC 60934)
0.5 kV/pollution degree 2 reinforced insulation in operating area
Dielectric strength max. 32 V DC (load circuit)
Isolation resistance (OFF condition) n/a, only electronic disconnection
Approvals/Declarations of conformity
UL 2367 Solid State Overcurrent Protectors UL 1604, (class I, division 2, groups A, B, C, D) UL 508 CSA C22.2 No. 213 (class I, division 2) CSA C22.2 No. 142 CE logo
Dimensions (B x H x T) 12.5 x 80 x 83 mm
Weight approx. 65 g
Terminals Line+/LOAD+/0V
Screw terminals M4
Max. cable cross section flexible with wire end ferrule w/wo plastic sleeve 0.5 – 10 mm2
Multi-lead connection (2 identical cables) rigid/flexible 0.5 – 4 mm2
Flexible with wire end ferrule without plastic sleeve 0.5 – 2.5 mm2
Flexible with TWIN wire end ferrule with plastic sleeve 0.5 – 6 mm2
Wire stripping length 10 mm
Tightening torque (EN 60934) 1.5 – 1.8 Nm
Terminals aux. contacts
Screw terminals M3
Max. cable cross section flexible with wire end ferrule w/wo plastic sleeve
0.25 - 2.5 mm2
Wire stripping length 8 mm
Tightening torque (EN 60934) 0.5 Nm
Table 1: voltage drop, current limitation, max. load currentcurrent rating typically voltage drop active current max. load current at 100 % ON duty
IN UON at IN limitation (typically) Tambient = 40 °C Tambient = 40 °C
0.5 A 70 mV 1.8 x IN
0.5 A 0.5 A
1 A 80 mV 1.8 x IN
1 A 1 A
2 A 130 mV 1.8 x IN
2 A 2 A
3 A 80 mV 1.8 x IN
3 A 3 A
4 A 100 mV 1.8 x IN
4 A 4 A
6 A 130 mV 1.8 x IN
6 A 5 A
8 A 120 mV 1.5 x IN
8 A 7 A
10 A 150 mV 1.5 x IN
10 A 9 A
12 A 180 mV 1.3 x IN
12 A 10.8 A
Attention: when mounted side-by-side without convection the ERD24 should not carry more than 80 % of its rated load with 100 % ON duty due to thermal effects.
3
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/78
Electronic protection devices EPD24
Technical information
Time/Current characteristic curve (Tambient = 25 °C)
The trip time is typically 3 s in the range between 1.1 and 1.8 x IN
1)
.
Electronic current limitation occurs at typically 1.8 x IN
1) which means that under all overload conditions (independent of the power sup-
ply and the resistance of the load circuit) the max. overload before disconnection will not exceed 1.8 x IN
1) times the current rating. Trip
time is between 100 ms and 3 sec (depending on overload or at short circuit).
Without this current limitation a considerably higher overload current would flow in the event of an overload or short circuit.
disconnection typically 1.1 x IN
current limitationtypically 1.8 x IN
1)
IK
10000
1000
1 2 4
trip
tim
e in
sec
ond
s
...times rated current
100
10
1
0.1
0.01
3 50
1.8 x IN1)
5
1) Current limitation typically 1.8 x IN at I
N = 0.5 A...6 A
Current limitation typically 1.5 x IN at I
N = 8 A or 10 A
Current limitation typically 1.3 x IN at I
N = 12 A
Maximum cable lenghtsEPD24 reliably trips from 0 Ω up to max. circuit resistance R
max.
Calculation of Rmax
Selected rating IN (A) 3 6
Operating voltage US (V DC) (= 80 % of 24 V) 2) 19.2 19.2
Trip current Iab
= 1.25 x IN (A) (EPD24 trips after 3 s) 3.75 7.50
Rmax (Ω) = (UB/Iab) -0.050 5.07 2.51
2) Voltage drop of EPD24 and tolerance of trip point (typically 1.1 x IN = 1.05 ... 1.35 x I
N) have been taken into account
Selection table for the incoming cable lengths with different cable cross-sections
Cable cross section A (mm2) 0.14 0.25 0.34 0.5 0.75 1.00 1.50
Cable length L (m) (= single length) cable resistance (Ω) = (0 x 2 x L) / A 3)
5 1.27 0.71 0.52 0.36 0.24 0.18 0.12
10 2.54 1.42 1.05 0.71 0.47 0.36 0.24
15 3.81 2.14 1.57 1.07 0.71 0.53 0.36
20 5.09 2.85 2.09 1.42 0.95 0.71 0.47
25 6.36 3.56 2.62 1.78 1.19 0.89 0.59
30 7.63 4.27 3.14 2.14 1.42 1.07 0.71
35 8.90 4.98 3.66 2.49 1.66 1.25 0.83
40 10.17 5.70 4.19 2.85 1.90 1.42 0.95
45 11.44 6.41 4.71 3.20 2.14 1.60 1.07
50 12.71 7.12 5.24 3.56 2.37 1.78 1.19
75 19.07 10.68 7.85 5.34 3.56 2.67 1.78
100 25.34 14.24 10.47 7.12 4.75 3.56 2.37
125 31.79 17.80 13.09 8.90 5.93 4.45 2.97
150 38.14 21.36 15.71 10.68 7.12 5.34 3.56
175 44.50 24.92 18.32 12.46 8.31 6.23 4.15
200 50.86 28.48 20.94 14.24 9.49 7.12 4.75
225 57.21 32.04 23.56 16.02 10.68 8.01 5.34
250 63.57 35.60 26.18 17.80 11.87 8.90 5.93
3) Resistivity of copper = 0.0178 (Ω x mm2)/m
Example 1: max. length for 1.5 mm2 and 3 A: 214 m
Example 2: max. length for 1.5 mm2 and 6 A: 106 m
Example 3: mixed wiring: (Control cabinet --- sensor/actuator level)
R1 = 40 m for 1.5 mm2 and R2 = 5 m for 0.25 mm2:
R1 = 0.95 Ω, R2 = 0.71 Ω, total (R1 + R2) = 1.66 Ω
3
3/79 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Electronic protection devices EPD24
Approvals, Safety instructions
Please note
The user must ensure that the cable cross sections of the relevant load circuit are suitable for the current rating of the EPD24
used. Automatic start-up of machinery after shut down must be prevented (Machinery Directive 98/37/EG and EN 60204-1).
In the event of a short circuit or overload the load circuit will be disconnected electronically by the EPD24.
Information on UL approvals/CSA approvals
UL1604
UL File # E 339238
CSA C22.2 No. 213 (Class I, Division 2)
CSA File # 2305929
Operating Temperature Code T5 – This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D or non-hazardous locations only
WARNING: – Exposure to some chemicals may degrade the sealing properties of materials used in the following device: relay
Sealant Material:
– Generic Name: Modified diglycidyl ether of bisphenol A
– Supplier: Fine Polymers Corporation
– Type: Epi Fine 4616L-160PK
– Casing Material:
– Generic Name: Liquid Crystal Polymer
– Supplier: Sumitomo Chemical
– Type: E4008, E4009, or E6008
RECOMMENDATION: – Periodically inspect the device named above for any degradation of properties and replace if degradation is found
WARNING – EXPLOSION HAZARD: – Do not disconnect equipment unless power has been removed or the area is known to be non-hazardous
– Substitution of any components may impair suitability for Class I, Division 2
UL2367
Non-hazardous use - UL File # E 339236
UL 508
Non-hazardous use - UL File # E 149922
CSA C22.2 No. 14
CSA C22.2 No. 142 - CSA File # E 2305929
Class 2
Meets requirement for Class 2 current limitation (EPD24 ... -0,5 A/1 A/2 A/3 A)
3
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/80
Electronic protection devices EPD24
Installation guidelines
The EPD24 features an integral power distribution system.
The following wiring modes are possible with various pluggable current and signal busbars:
– LINE+ (24 V DC)
– 0 V
Caution: The electronic devices EPD24 require a 0 V connection
– Auxiliary contacts
Mounting procedure
Before wiring insert busbars into protector block. A maximum of 10 connection cycles are permissible using connecting bus-
bars.
RecommendationAfter 10 units the busbars should be interrupted and receive a new entry live.
Table of length for busbars(Order code 2CDE605100R0500)
No. of units 2 3 4 5 6 7 8 9 10
Length of busbar (mm) ± 0.5 mm 22 34.5 47 59.5 72 84.5 97 109.5 122
12.5 x n = width of protector block
e. g. 12.5 x 5 = 62.5insert busbarsand protection slidesto be flush with housing sides
insert signal
bars to be flush with
housing and place them
centrally over the contacts
LINE+ busbar2CDE605100R0500
0 V busbar2CDE605100R0500
signal bar2CDE605200R0021
remove protection againstbrush contact from bottom side
(12.5 x n)-3 = length of busbars ± 0.5
e. g. (12.5 x 5)-3 = 59.5 ± 0.5
insert protection againstbrush contact
continuous busbar
500 mm length, cut
4
4/1 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Analog signal converters
Product group picture
4
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/2
Analog signal converters
Table of contents
Analog signal converters
Overview 4/3
Analog signal converters - CC-E range .............................................. 4/4
Benefits and advantages 4/4
Ordering details - Standard signal converters 4/5
Ordering details - RTD converters 4/6
Ordering details - Thermocouple converters 4/7
Ordering details - Measuring converters 4/8
DIP switch settings, Dimensional drawings 4/9
Wiring instructions 4/10
Technical data 4/11
Analog signal converters - CC-U range ............................................ 4/14
Overview 4/14
Ordering details 4/16
Ordering details - Accessories 4/17
DIP switch settings 4/18
Wiring instructions 4/20
Technical information 4/21
Technical data 4/24
Technical diagr., Connection diagr., Dimensional drawings 4/27
4
4/3 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Analog signal converters
Overview
Applications for analog signal processing and correct solution using CC-E and CC-U converters
Nearly every process includes a control system that receives
data by means of analog signals and then evaluates the data
and sets the respective parameters correspondingly.
When transmitting analog signals numerous problems may
arise which can disturb or even block an ideal behavior of the
process.
Below we have listed some processing problems together
with the respective solutions to solve these problems:
Signal conversionSometimes the available signals cannot be processed by the
controller or the actuator. In this case, signal converters are
required to convert the input signal (or different input signals)
to the desired output signal.
Signal amplificationIf long lines or high burdens have to be operated, it may be
necessary to amplify the signal. CC analog signal converters
require only low input power and provide high output power.
Thus, there are no restrictions for the converter's position on
the line, i.e. it can be used
– for signal refreshing (1) at the end of the line (low input
power)
– or for signal amplification (2) at the beginning of the line
(high output power).
Signal filteringParticularly on long lines or in rough industrial environments
the signals are exposed to high electromagnetic interferenc-
es. The frequency of the coupled interference signals may be
in the range of the common mains frequency (50 Hz) or even
much higher (in case of frequency converters). According to
the specific requirements, analog signal converters are avail-
able which provide reliable suppression of those interferences
by means of an input low-pass filter.
Signal separation – Protection against overvoltage
The increased use of micro-electronics make controls
much more sensitive against overvoltages, resulting from
lightning discharges or switching processes. Suppression
diodes are incorporated in the input of the CC analog
signal converters which enable the converters to arrest
overvoltages with low energy level (resulting from switch-
ing processes) by themselves. The products furthermore
provide electrical isolation between input, output and
supply circuit for protection of the controller connected to
the output.
– Protection against ground loops If components are used which refer to ground, the mea-
suring signals can be falsified by a so-called ground loop.
In this case, certain parts of the signal are transmitted
via earth and not via the analog transmission line, thus
causing incorrect evaluation of the signal. The electrical
isolation between the input and the output disconnects
these ground loops and thus enables correct signal
transmission.
� existing
� existing for some devices
� pending
Approvals CC
-E/S
TD
CC
-E I
/I
CC
-U/S
TD
CC
-U/S
TD
R
CC
-E/R
TD
CC
-U/R
TD
CC
-U/R
TD
R
CC
-E/T
C
CC
-U/T
C
CC
-U/T
CR
CC
-E/I
CC
-E I
AC/I
LP
O
CC
-U/I
CC
-U/V
A UL 508, CAN/CSA C22.2 No.14 � � � � � � � � � � � � � �
AUL 1604 (Class I, Div 2, hazardous locations),
CAN/CSA C22.2 No.213� � � � � � � � �
K CB scheme � � �E CCC � � �
Marks
a CE � � � � � � � � � � � � � �
b C-Tick � � � � � � � � � � � � � �
0-10 V0-10 V
100 m 0-20 mA 100 m 4-20 mA
2C
DC
28
2 0
13
F0
20
6
Controllere.g. AC500
Measuring sensor
Actuator
1. Analog signal converter
(e.g. CC-E or CC-U)
2. Analog signal converter
(e.g. CC-E or CC-U)
4
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/4
Analog signal converters - CC-E range
Benefits and advantages
CC-E/STD analog signal converter with 3-way electrical isolation – 2 universally configurable devices (type CC-E/STD)
– 2x10 single-function devices
– "Plug and Work", no adjustment of single-function devices
required
CC-E/RTD temperature signal converter for RTD sensors, linearized with 3-way electrical isolation – 2 universally configurable devices (type CC-E/RTD)
– 2x12 single-function devices
– Plug and Work", no adjustment of single-function devices
required
– Temperature signal converter for PT100 sensors
– 2- or 3-wire connection
CC-E/TC analog signal converter for thermocouple signals of the types J and K with 3-way electrical isolation – 2 universally configurable devices (type CC-E/TC)
– 2x6 single-function devices
– "Plug and Work", no adjustment of single-function devices
required
– Integrated cold-junction compensation
CC-E/I measuring converter for current signals 0-5 A, 0-20 A, AC/DC with 3-way electrical isolation – 2 universally configurable devices (type CC-E/I)
– 2x6 single-function devices
– "Plug and Work", no adjustment of single-function devices
required
CC-E IAC/ILPO measuring converter without auxiliary power for sinusoidal currents 0-1 A, 0-5 A, output 4-20 mA – Measuring converter for sinusoidal currents (0-1 A, 0-5 A)
– Measuring range selection by front-face sliding switch
– 4-20 mA output current in proportion to input current
– no additional power supply required
CC-E range – Universally configurable devices and single-function
devices
– Adjustment and operating elements on the front side
– Safe operation by electrical 3-way isolation
– Unambiguous and clear connecting terminal markings
Conversion, measurement and separation of – Standard signals (0-5 V, 0-10 V, 0-20 mA, 4-20 mA)
– Temperature signals of RTD sensors (PT 100)
– Thermocouple signals (types J and K)
– Current measurement signals (0-5 A, 0-20 A AC/DC)
Characteristics of single-function devices – No adjustment or balancing necessary.
Characteristics of universal devices – The required input and output ranges can be configured by
means of directly accessible DIP switches positioned on
the side
– Gain adjustment of ±5 % by means of an adjustment
potentiometer on the front-side
– Offset adjustment of ±5 % by means of adjustment potenti-
ometers on the front-side
Loop-powered current/current isolator without external power supply for analog current signals of 0-20 mA and 4-20 mA – Electrical isolation between input and output
– Very low internal voltage drop � 2.5 V
– Available with one or two independent channels
– Width only 18 mm (1 and 2 channels)
4
1
1
2
2
3
5
1 Terminals M, K, J, H, G
2 Terminal explanation
3 Adjustment of gain
4 Adjustment of offset
4 Indication of operational states U - control supply voltage applied
4
4/5 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Analog signal converters - CC-E range
Ordering details - Standard signal converters
1) B 1604 Class I, Div.2 (universal device)2) CC-E-I/I-1 has 1 channel, CC-E-I/I-2 has 2 channels
Ordering details - Standard signal convertersSupply voltage range
Input signal Output signal Type Order code Price
1 pce
Weight(1 pce)kg (lb)
24 V DC
0-5 V, 0-10 V,
0-20 mA,
4-20 mA
0-5 V, 0-10 V,
0-20 mA, 4-20 mACC-E/STD1) 1SVR011700R0000
0.088
(0.194)
0-10 V
0-10 V CC-E V/V 1SVR011710R21000.083
(0.183)
0-20 mA CC-E V/I 1SVR011711R16000.084
(0.185)
4-20 mA CC-E V/I 1SVR011712R17000.084
(0.187)
0-20 mA
0-10 V CC-E I/V 1SVR011713R10000.082
(0.181)
0-20 mA CC-E I/I 1SVR011714R11000.084
(0.187)
4-20 mA CC-E I/I 1SVR011715R12000.084
(0.185)
4-20 mA
0-10 V CC-E I/V 1SVR011716R13000.084
(0.185)0-20 mA CC-E I/I 1SVR011717R1400
4-20 mA CC-E I/I 1SVR011718R25000.084
(0.187)
-10...+10 V -10...+10 V CC-E V/V 1SVR011719R26000.082
(0.181)
110-240 V AC
0-5 V, 0-10 V,
0-20 mA,
4-20 mA
0-5 V, 0-10 V,
0-20 mA, 4-20 mACC-E/STD 1SVR011705R2100
0.090
(0.198)
0-10 V
0-10 V CC-E V/V 1SVR011720R23000.096
(0.212)
0-20 mA CC-E V/I 1SVR011721R10000.087
(0.192)
4-20 mA CC-E V/I 1SVR011722R11000.091
(0.200)
0-20 mA
0-10 V CC-E V/V 1SVR011723R12000.091
(0.200)
0-20 mA CC-E I/I 1SVR011724R13000.088
(0.194)4-20 mA CC-E I/I 1SVR011725R1400
4-20 mA
0-10 V CC-E V/V 1SVR011726R15000.096
(0.212)
0-20 mA CC-E I/I 1SVR011727R16000.087
(0.192)
4-20 mA CC-E I/I 1SVR011728R27000.088
(0.194)
loop powered
-10...+10 V -10...+10 V CC-E V/V 1SVR011729R20000.086
(0.190)
0-20 mA,
4-20 mA0-20 mA, 4-20 mA
CC-E I/I-12) 1SVR010200R16000.038
(0.084)
CC-E I/I-22) 1SVR010201R03000.044
(0.097)
2C
DC
28
1 0
10
F0
00
32
CD
C 2
81
00
1 F
00
03
2C
DC
28
1 0
41
F0
00
3
CC-E/I
CC-E V/V
CC-E I/I-2
4
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/6
Analog signal converters - CC-E range
Ordering details - RTD converters
2C
DC
28
1 0
04
F0
00
3
CC-E/RTD
Ordering details - RTD convertersSupply voltage range
Input signal Output signal Type Order code Price
1 pce
Weight(1 pce)kg (lb)
24 V DC
refer to table0-10 V, 0-20 mA,
4-20 mACC-E/RTD1) 1SVR011701R2500
0.091
(0.200)
PT100
0...100 °C
0-10 V CC-E RTD/V 1SVR011730R25000.084
(0.185)
0-20 mA CC-E RTD/I 1SVR011731R12000.086
(0.190)4-20 mA CC-E RTD/I 1SVR011732R1300
PT100
-50...+50 °C
0-10 V CC-E RTD/V 1SVR011733R14000.083
(0.183)
0-20 mA CC-E RTD/I 1SVR011734R15000.084
(0.185)
4-20 mA CC-E RTD/I 1SVR011735R16000.084
(0.187)
PT100
0...300 °C
0-10 V CC-E RTD/V 1SVR011736R17000.084
(0.185)
0-20 mA CC-E RTD/I 1SVR011737R10000.084
(0.187)
4-20 mA CC-E RTD/I 1SVR011738R2100 0.101
PT100
-50...+250 °C
0-10 V CC-E RTD/V 1SVR011739R22000.084
(0.185)
0-20 mA CC-E RTD/I 1SVR011740R07000.084
(0.187)4-20 mA CC-E RTD/I 1SVR011741R2400
110-240 V AC
refer to table0-10 V, 0-20 mA,
4-20 mACC-E/RTD 1SVR011706R2200
0.093
(0.205)
PT100
0...100 °C
0-10 V CC-E RTD/V 1SVR011788R24000.086
(0.190)
0-20 mA CC-E RTD/I 1SVR011789R25000.088
(0.194)
4-20 mA CC-E RTD/I 1SVR011790R22000.089
(0.196)
PT100
-50...+50 °C
0-10 V CC-E RTD/V 1SVR011791R17000.087
(0.192)
0-20 mA CC-E RTD/I 1SVR011792R10000.089
(0.196)4-20 mA CC-E RTD/I 1SVR011793R1100
PT100
0...300 °C
0-10 V CC-E RTD/V 1SVR011794R12000.087
(0.192)
0-20 mA CC-E RTD/I 1SVR011795R13000.089
(0.196)4-20 mA CC-E RTD/I 1SVR011796R1400
PT100
-50...+250 °C
0-10 V CC-E RTD/V 1SVR011797R15000.086
(0.190)
0-20 mA CC-E RTD/I 1SVR011798R26000.089
(0.196)
4-20 mA CC-E RTD/I 1SVR011799R27000.088
(0.194)
1) B 1604 Class I, Div.2 (universal device)
4
4/7 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Analog signal converters - CC-E range
Ordering details - Thermocouple converters2
CD
C 2
81
00
7 F
00
03
CC-E TC
Ordering details - Thermocouple ConvertersSupply voltage range
Input signal Output signal Type Order code Price
1 pce
Weight(1 pce)kg (lb)
24 V DC
thermocouple types J and K
0-10 V, 0-20 mA,
4-20 mACC-E/TC1) 1SVR011702R2600
0.089
(0.196)
type J 0...600 °C
0-10 V CC-E TC/V 1SVR011750R01000.087
(0.192)
0-20 mA CC-E TC/I 1SVR011751R26000.084
(0.187)
4-20 mA CC-E TC/I 1SVR011752R2700 0.102
type K 0...1000 °C
0-10 V CC-E TC/V 1SVR011753R20000.084
(0.185)0-20 mA CC-E TC/I 1SVR011754R2100
4-20 mA CC-E TC/I 1SVR011755R22000.086
(0.190)
110-240 V AC
thermocouple types J and K
0-10 V, 0-20 mA,
4-20 mACC-E/TC 1SVR011707R2300
0.088
(0.194)
type J 0...600 °C
0-10 V CC-E TC/V 1SVR011760R03000.084
(0.187)
0-20 mA CC-E TC/I 1SVR011761R20000.088
(0.194)
4-20 mA CC-E TC/I 1SVR011762R21000.1
(0.220)
type K 0...1000 °C
0-10 V CC-E TC/V 1SVR011763R22000.086
(0.190)
0-20 mA CC-E TC/I 1SVR011764R23000.088
(0.194)
4-20 mA CC-E TC/I 1SVR011765R24000.086
(0.190)
1) B 1604 Class I, Div.2 (universal device)
4
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/8
Ordering details - Measuring ConvertersSupply voltage range
Input signal Output signal Type Order code Price
1 pce
Weight(1 pce)kg (lb)
24 V DC
0-5 A, 0-20 A,
AC/DC
0-10 V, 0-20 mA,
4-20 mACC-E/I1) 1SVR011703R2700
0.096
(0.212)
0-5 A, 0-20 A,
AC
0-10 V CC-E IAC
/V 1SVR011770R05000.090
(0.198)
0-20 mA CC-E IAC
/I 1SVR011771R2200 0.092
(0.203)4-20 mA CC-E IAC
/I 1SVR011772R2300
0-5 A, 0-20 A,
DC
0-10 V CC-E IDC
/V 1SVR011773R24000.092
(0.207)
0-20 mA CC-E IDC
/I 1SVR011774R25000.091
(0.200)
4-20 mA CC-E IDC
/I 1SVR011775R26000.093
(0.205)
110-240 V AC
0-5 A, 0-20 A,
AC/DC
0-10 V, 0-20 mA,
4-20 mACC-E/I 1SVR011708R0400
0.099
(0.218)
0-5 A, 0-20 A,
AC
0-10 V CC-E IAC
/V 1SVR011780R11000.092
(0.203)
0-20 mA CC-E IAC
/I 1SVR011781R06000.092
(0.207)
4-20 mA CC-E IAC
/I 1SVR011782R07000.095
(0.209)
0-5 A, 0-20 A,
DC
0-10 V CC-E IDC
/V 1SVR011783R00000.093
(0.205)
0-20 mA CC-E IDC
/I 1SVR011784R0100 0.095
(0.209)4-20 mA CC-E IDC
/I 1SVR011785R1100
loop powered 0-1 A, 0-5 A, AC 4-20 mA CC-E IAC
/ILPO2) 1SVR010203R05000.052
(0.115)
2C
DC
28
1 0
18
F0
00
4
CC-E IAC/ILPO
1) B 1604 Class I, Div.2 (universal device)2) for sinusoidal currents
Analog signal converters - CC-E range
Ordering details - Measuring converters
4
4/9 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Analog signal converters - CC-E range
DIP switch settings, Dimensional drawings
81 2 43 5 6 7
0...5 V
0...10 V
0...20 mA
4...20 mA
0...5 V0...10 V
0...20 mA4...20 mA
0...5 V0...10 V
0...20 mA4...20 mA
0...5 V0...10 V
0...20 mA4...20 mA
0...5 V0...10 V
0...20 mA4...20 mA 2C
DC
282
001
F02
04
Input OutputSwitch
2CD
C 2
82 0
02 F
0204
ONLegend
OFF
CC-E/STD, CC-E x/x (universal devices)
2CD
C 2
82 0
03 F
0204
OFF
Legend
no influence
ON
1 2 43 5 6
0...300 °C
0...100 °C
0...500 °C
-50...+50 °C
-50...+250 °C
-50...+450 °C
High fail safeLow fail safe
0...10 V0-20 mA4-20 mA0-10 V
0-20 mA4-20 mA0-10 V
0-20 mA4-20 mA0-10 V
0-20 mA4-20 mA0-10 V
0-20 mA4-20 mA0-10 V
0-20 mA4-20 mA
2CD
C 2
82 0
06 F
0208
Input OutputSwitch
CC-E/RTD
2CD
C 2
82 0
03 F
0204
OFF
Legend
no influence
ON
1 2 43 5 6
TC-J: 0...600 °C
TC-K:0...1000 °C
High fail safeLow fail safe
0...10 V0...20 mA4...20 mA0...10 V
0...20 mA4...20 mA
2CD
C 2
82 0
07 F
0208
Input OutputSwitch
CC-E/TC CC-E/I
Dimensional drawings
2CD
C 2
82 0
02 F
0204
ONLegend
OFF
1 2 43 5 6
I - DCI - AC
I - AC
I - DCI - ACI - DC
0...10 V
0...20 mA
4...20 mA
2CD
C 2
82 0
05 F
0208Input Output
Switch
2CD
C 2
82 0
11 F
0204
Select input range by terminals
Input range 5 A
Connected linesUsed terminalsTerminal marking
Input range 20 A
Connected linesUsed terminalsTerminal marking
Input range selection - CC-E/I
CC-E/x CC-E IAC/ILPO, CC-E I/I
22.5
0,88 " 2C
DC
282 0
11 F
0b
06
18
0.71" 2C
DC
282 0
12 F
0b
06
4
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/10
CC-E/STD, CC-E x/x (universal devices)
2CD
C 2
82 0
06 F
0206
BurdenR � 1.0 k�
BurdenR � 500 �
supply
CC-E/RTD
J
H
G
2CD
C 2
82 0
07 F
0206
BurdenR � 1.0 k�
BurdenR � 500 �
supply
CC-E/TC
2CD
C 2
82 0
08 F
0206
BurdenR � 1.0 k�
BurdenR � 500 �
supply
RL � 500 �
UL
C
D
F
E
IN
IN
OUT
OUT
2C
DC
28
2 0
03
F0
20
5
Channel 1
input
0-20 mA or
4-20 mA
Channel 1
output
0-20 mA or
4-20 mA
J
H
G
20 A
5 A
A
C
D
F
V
I
K
-
M
+
+
-
+
-
IN OUTI
2CD
C 2
82 0
08 F
0208
BurdenR � 1.0 k�
BurdenR � 500 �
supply
RL � 500 �
RL � 500 �
UL
UL
C
D
F
E
A
B
H
G
IN
IN
IN
IN
OUT
OUT
OUT
OUT
2C
DC
28
2 0
04
F0
20
5
Channel 1
input
0-20 mA or
4-20 mA
Channel 2
input
0-20 mA or
4-20 mA
Channel 1
output
0-20 mA or
4-20 mA
Chanel 2
output
0-20 mA or
4-20 mA
CC-E I/I-1
CC-E I/I
2CD
C 2
82 0
10 F
0b06
CC-E IAC/ILPO
Analog signal converters - CC-E range
Wiring instructions
CC-E I/I-2
4
4/11 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Analog signal converters - CC-E range
Technical data
Type CC-E/STD / CC-E x/x CC-E/RTD 3) CC-E/TCInput circuits - Analog inputs J-G-H Current Voltage Temperature sensors Thermocouples
(IEC 584-1 and 2)Input signal Standard signals PT100 TC.K, TC.J
Rated input range 0...20 mA /4...20 mA
0...5 V /0...10 V /-10...+10 V
-50...+500 °C TC.K: 0...1000 °C, TC.J: 0...600 °C
Limitation of input signals +55 mA ± 11 VInfluence of line resistance - < 0.01 %/� < 0.5 % / 100 �Gain adjustment range ± 5 % (universal devices)Offset adjustment range ± 5 % (universal devices)
Input impedance 50 � 1 M� - -
Suppression at 50 Hz - - > 35 dB
Common-mode rejection - 100 dBOutput circuits - Analog outputs D-F, A-C Current VoltageOutput signal 0-20 mA, 4-20 mA 0-5 V, 0-10 V
Output burden � 500 � �1.0 K�Accuracy 1) ± 0.5 % of full-scale
Residual ripple < 0.5 %
Response time 200 μs 10 ms
Transmission frequency 2 kHz 80 Hz 2 Hz (up to -3 dB)Reaction to input circuit interruption High fail safe: Output voltage > 115 % of
measuring range 2) Low fail safe: Output voltage < -0.6 V, output current = 0 mA
Supply circuits K-M DC versions AC versionsSupply voltage 24 V DC 110-240 V AC - 50/60 Hz
Supply voltage tolerance -15...+15 % -15...+10 %Power consumption 1.5 W typ. 1.5 VA typ.
Indication of operational statesRated control supply voltage U
SU: green LED
General dataAmbient temperature range operation / storage 0...+60 °C / -20...+80 °CTemperature coefficient ± 500 ppm/°CDegree of protection (DIN 40050) IP20Mounting position ventilation slots on top and bottom
Mounting DIN rail (IEC/EN 60715), snap-on mounting
Electrical connectionWire size rigid 0.2-4 mm2 (24-12 AWG)
fine-strand with(out) wire end ferrule 0.2-2.5 mm2 (24-14 AWG)Stripping length 7 mm (0.28 inch)Tightening torque 0.5 Nm (4.4 lb.in)Electromagnetic compatibilityInterference immunity EN 61000-6-2electrostatic discharge (ESD) IEC/EN 61000-4-2 Level 3 (±6 kV / ±8 kV)electromagnetic field(HF radiation resistance)
IEC/EN 61000-4-3 10 V/m
fast transients (Burst) IEC/EN 61000-4-4 Level 3 (±2 kV / 5 kH)powerful impulses (Surge) IEC/EN 61000-4-5 ±2 kV / ±1 kVHF line emission IEC/EN 61000-4-6 10 VInterference emission EN 61000-6-4 Class BIsolation dataTest voltage between all isolated circuits 2.5 kV ACRated insulation voltage - - -
1) Includes non-linearity and factory setting, influenced by supply voltage and output load.2) Only -/RTD and -/TC: Single-function devices respond with Low fail safe to input signal interruptions.3) When connecting a 2-wire sensor, the terminals J and H have to be jumpered.
Approvals see „Overview“ on page 4/3
4
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/12
Type CC-E I/I-1 / CC-E I/I-2Input circuits - Analog inputs CurrentInput current I
IN 0-20 mA, 4-20 mA
Min. input current < 100 μA
Max. input current 50 mA1) (VIN
< 18 V)
Input voltage UIN < 2.5 V + (I
IN x R
L)
Input voltage drop Ui < 2.5 V (20 mA, RL = 0 �)
Max. input voltage 18 V1) (IIN
< 50 mA)Output circuitsOutput current I
OUT 0-20 mA, 4-20 mA
Output load RL
0-500 �Output voltage U
OUT IOUT
x RL
Residual ripple < 20 mVpp
(500 �, 20 mA)
Response time (0-100 %) < 15 ms (0-500 �, 20 mA), < 5 ms (500 q, 20 mA, 25 °C)
Accuracy � 0.1 % of full-scale (20 mA)Load influence (0-500 �) � �0.05 % / 100 �,
� -0.1 % / 100 � (25 °C)General dataWidth of the enclosure 18 mmWeight 1 channel approx. 0.037 kg (0.082 (0.181) lb)
2 channel approx. 0.044 (0.097) kg (0.097 lb)Mounting position anyDegree of protection enclosure / terminals IP20 / IP20Ambient temperature range operation / storage -25...+60 °C / -40...+85 °CTemperature coefficient < �50 ppm / °CMounting DIN rail (IEC/EN 60715)Electrical connectionWire size rigid 0.2-4 mm2 (24-12 AWG)
fine-strand with(out) wire end ferrule 0.2-2.5 mm2 (24-14 AWG)Stripping length 7 mm (0,28 inch)Tightening torque 0.5 Nm (4.4 lb.in)StandardsProduct standard EN 50178Low Voltage Directive 2006/95/ECEMC Directive 2004/108/ECElectromagnetic compatibility Interference immunity EN 61000-6-2electrostatic discharge (ESD) EN 61000-4-2 Level 3 (±6 kV / ±8 kV)electromagnetic field (HF radiation resistance)
EN 61000-4-310 V/m
fast transients (Burst) EN 61000-4-4 Level 3 (±2 kV / 5 kH)powerful impulses (Surge) EN 61000-4-5 ±2 kV / ±1 kVHF line emission EN 61000-4-6 10 Vmagnetic fields EN 61000-4-8 30 A/mInterference emission EN 61000-6-4Radiated noise EN 55011 Class BOperational reliability (EN 68-2-6) 4 gMechanical resistance (EN 68-2-6) 10 gEnvironmental testing (IEC 68-2-30 Db) 24 h cycle, 55 °C, 93 % rel., 96 hIsolation dataInsulation voltage input / output 500 V
eff / 50 Hz
Insulation voltage between channels 5 kVeff
/ 50 Hz (device with 2 channels)Pollution category 2Overvoltage category II
1) The input parameters have to be limited to the indicated maximum values.
Approvals see „Overview“ on page 4/3
Analog signal converters - CC-E range
Technical data
4
4/13 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Analog signal converters - CC-E range
Technical data
Type CC-E/I CC-E IAC/ILPO Input circuits - Analog inputs
J-G-H C-DAC current DC current 2 meas. ranges selectable
Rated input range 0-5 A / 0-20 A 0-5 A / 0-20 A 0-1 A / 0-5 A / sinusoidalMeasuring frequency 50/60 HzOverload capacity of inputs input range 1 10 x I
Nom (50 A) for max. 1 s 10 x I
Nom (50 A) for max. 2 s
input range 2 10 x INom
(200 A) for max. 1 s 10 x INom
(200 A) for max. 2 s
Gain adjustment range ±5 % (universal devices) -Offset adjustment range ±5 % (universal devices) -Input impedance / resistance 5A : 65 m� 20 A : 2.5 m� 5 m�Output circuits - Analog outputs D-F Current A-C Voltage F-E passive current output in pro-
portion to input currentOutput signal 0-20 mA /
4-20 mA0-10 V 4-20 mA
Output burden / load� 500 � � 1.0 �
12 V DC: 150 �, 24 V DC: 750 � 30 V DC: 1050 �
Accuracy 1) ± 2 % of full-scaleOffset adjustment range ±5 % (universal device) ± 5 %Gain adjustment range ±5 % (universal device) ± 20 %Residual ripple < 0.5 %Response time 0.5 s 0.6 sTransmission frequency DC or 50/60 Hz AC: 50/60 HzReaction to input circuit interruption Low fail safe: output voltage
< 200 mV, output current < 400 μA-
Supply circuits K-M DC versions AC versionsSupply voltage
24 V DC110-240 V AC 50/60 Hz
12-30 V DC
Supply voltage tolerance -15...+15 % -15...+10 % -
Power consumption typ 1.5 W typ 1.5 VA -Indication of operational statesSupply voltage U: green LED -General dataAmbient temperature range operation / storage 0...+60 °C / -20...+80 °C -20...+60 °C / -40...+80 °CTemperature coefficient ± 500 ppm/°C 300 ppm/°CDegree of protection (DIN 40050) IP20Mounting position ventilation slots on top and bottomMounting DIN rail (IEC/EN 60715), snap-on mountingElectrical connectionWire size rigid 0.2-4 mm² (24-12 AWG)
fine-strand with(out) wire end ferrule 0.2-2.5 mm² (24-14 AWG)Stripping length 7 mm (0.28 inch)Tightening torque 0.5 Nm (4.4 lb.in)Electromagnetic compatibilityInterference immunity EN 61000-6-2electrostatic discharge (ESD) IEC/EN 61000-4-2 Level 3 (±6 kV / ±8 kV)electromagnetic field (HF radiation resistance) IEC/EN 61000-4-3 10 V/mfast transients (Burst) IEC/EN 61000-4-4 Level 3 (±2 kV / 5 kH)powerful impulses (Surge) IEC/EN 61000-4-5 ±2 kV / ±1 kVHF line emission IEC/EN 61000-4-6 10 VInterference emission EN 61000-6-4 Class BIsolation dataTest voltage (between all isolated circuits) 2.5 kV ACRated insulation voltage - 250 V AC
1) Includes non-linearity and factory setting, influenced by supply voltage and output load.
Approvals see „Overview“ on page 4/3
4
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/14
Analog signal converters - CC-U range
Overview
CC-U range – 8 different standard signal outputs on one device
– Input and output side universally configurable
– Also available with 2 threshold relay outputs
– Adjustment and operating elements on the front side
– Safe operation by electrical 3-way isolation
– Plug-in connecting terminals, unambiguously and clearly
marked
Conversion, measurement and separation of – Standard signals
– Signals of RTD sensors (PT10, PT100, PT1000)
– Thermocouple signals
– TRMS values of currents and voltages
Characteristics – The required input and output ranges can be configured
for all devices by means of directly accessible DIP switches
positioned on the side.
– Due to the wide input range of the gain and offset stages
all input signals between the minimum and the maximum
input value can be universally converted to all common
output signals.
– Devices for DC or AC (50/60 Hz) supply available.
4
1
1
2
2
3
5
1 Terminals +, V/I+, V/I-, PW DC, IN, -
2 Terminal explanation
3 Adjustment of resistance value R1
4 Adjustment of hysteresis
4 Adjustment of resistance value R2
Adjustment of hysteresis7 Indication of operational states
R1 yellow LED - resistance value R1
R2 yellow LED - resistance value R2
U green LED - supply voltage
8 Marker label
7
8
4
4/15 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Analog signal converters - CC-U range
Overview
CC-U/STD universal signal converter with 3-way electrical isolation – More than 120 configurations possible
– Configurable output signal response on input voltage signal
interruption (low fail safe / high fail safe)
– Adjustment and operating elements on the front
– Short-circuit proof signal outputs
– Plug-in connecting terminals for inputs, outputs and supply
– Very fast signal transmission enables use in control sys-
tems
CC-U/STDR universal signal converter for standard signals, with 2 threshold relay outputs and with 3-way electrical isolation – Standard signal converter with 7 setting ranges
– 2 threshold relay outputs with one c/o contact each
(threshold and respective hysteresis can be
adjusted independently from each other)
– Open-circuit or closed-circuit principle configurable by
means of a DIP switch
– 2 yellow LEDs for clear status indication of the output
relays
– Plug-in connecting terminals for inputs, outputs and supply
CC-U/RTD universal signal converter for PT10, PT100, PT1000 temperature sensors (acc. to IEC 751 and JIS C 16041), linearized with 3-way electrical isolation) – Configurable output signal response on input signal inter-
ruption (low / high fail safe)
– Adjustment and operating elements on the front-side
– Short-circuit proof signal outputs
– Plug-in connecting terminals for inputs, outputs and supply
– 2- or 3-wire connection
CC-U/RTDR universal signal converter for temperature and resistance signals, with 2 threshold relay outputs and 3-way electrical isolation – Temperature signal converter for PT100 signals (5 ranges up
to 800 °C) and variable resistances from 0-380 � – 2 threshold relay outputs with one c/o contact each
(threshold and respective hysteresis can be adjusted inde-
pendently from each other)
– Open-circuit or closed-circuit principle configurable by
means of a DIP switch
– 2 yellow LEDs for clear status indication of the output relays
– Plug-in connecting terminals for inputs, outputs and supply
– 2- or 3-wire connection
CC-U/TC universal signal converter for thermocouples with 3-way electrical isolation – Temperature signal converter for thermo-couples of the
types K, J, T, S, E, N, R, B
– Continuously adjustable voltage signal input 0-10 mV and
0-50 mV
– Differential temperature meas. possible (see „Wiring
instructions“ on page 20)
– Configurable output signal response on input signal inter-
ruption (low fail safe / high fail safe)
– Adjustment and operating elements on the front-side
– Short-circuit proof signal outputs
– Plug-in connecting terminals for inputs, outputs and supply
– Cold-junction compensation selectable
CC-U/TCR universal signal converter for thermocouples, with 2 threshold relay outputs and 3-way electrical isolation – Temperature signal converter for thermocouples of the
types K, J, T, S
– 2 threshold relay outputs with one change-over contact
each (threshold and respective hysteresis can be adjusted
independently from each other)
– Open-circuit or closed-circuit principle configurable by
means of a DIP switch
– 2 yellow LEDs for clear status indication of the output
relays
– Plug-in connecting terminals for inputs, outputs and supply
– Integrated cold-junction compensation
CC-U/I universal measuring converter for RMS values of 0-1 A and 0-5 A, with 3-way electrical isolation – RMS converter for current signals up to 1 A and up to 5 A
of any wave form (DC, DC with superimposed AC compo-
nents, pure sinusoidal, triangular, phase-angle controlled,
etc. in a measuring range of 0-600 Hz)
– Adjustment and operating elements on the front
– Short-circuit proof signal outputs
– Plug-in connecting terminals for inputs, outputs and supply
CC-U/V universal measuring converter for RMS values of 0-600 V, with 3-way electrical isolation – RMS converter for voltage signals up to 600 V of any wave
form (DC, DC with superimposed AC components, pure
sinusoidal, triangular, phase-angle controlled, etc. in a
measuring range of 0-600 Hz)
– Adjustment and operating elements on the front
– Short-circuit proof signal outputs
– Plug-in connecting terminals for inputs, outputs and supply
1) Japanese standard
4
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/16
Analog signal converters - CC-U range
Ordering details
1) with relay output2) for current RMS values
3) for voltage RMS values
Ordering details - RTD ConvertersSupply voltage range
Input signal Output signal Type Order code Price
1 pce
Weight(1 pce)kg (lb)
24-48 V DC,
24 V AC
refer to table
refer to table CC-U/RTD
1SVR040002R05000.126
(0.278)
110-240 V AC,
100-300 V DC1SVR040003R0600
0.128
(0.282)
24-48 V DC,
24 V AC2 c/o CC-U/RTDR1)
1SVR040012R26000.146
(0.322)
110-240 V AC,
100-300 V DC1SVR040013R2700
0.148
(0.326)
Ordering details - Standard Signal ConvertersSupply voltage range
Input signal Output signal Type Order code Price
1 pce
Weight(1 pce)kg (lb)
24-48 V DC,
24 V AC
refer to table
refer to table CC-U/STD
1SVR040000R17000.125
(0.276)
110-240 V AC,
100-300 V DC1SVR040001R0400
0.126
(0.278)
24-48 V DC,
24 V AC2 c/o
CC-U/
STDR1)
1SVR040010R00000.142
(0.313)110-240 V AC,
100-300 V DC1SVR040011R2500
2C
DC
28
1 0
03
F0
00
3
2C
DC
28
1 0
05
F0
00
32
CD
C 2
81
00
8 F
00
03
2C
DC
28
1 0
12
F0
00
3
CC-U/STDR
CC-U/RTD
CC-U/TC
CC-U/I
Ordering details - Thermocouple ConvertersSupply voltage range
Input signal Output signal Type Order code Price
1 pce
Weight(1 pce)kg (lb)
24-48 V DC,
24 V AC
refer to table
refer to tableCC-U/TC
1SVR040004R07000.130
(0.287)
110-240 V AC,
100-300 V DC1SVR040005R0000
0.128
(0.282)
24-48 V DC,
24 V AC2 c/o CC-U/TCR1)
1SVR040014R20000.145
(0.320)110-240 V AC,
100-300 V DC1SVR040015R2100
Ordering details - Measuring ConvertersSupply voltage range
Input signal Output signal Type Order code Price
1 pce
Weight(1 pce)kg (lb)
24-48 V DC,
24 V AC
refer to table refer to table
CC-U/I2)
1SVR040006R01000.128
(0.282)
110-240 V AC,
100-300 V DC1SVR040007R0200
0.127
(0.280)
24-48 V DC,
24 V ACCC-U/V3)
1SVR040008R13000.128
(0.282)110-240 V AC,
100-300 V DC1SVR040009R1400
4
4/17 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Ordering details - AccessoriesFor type Width in mm Type Order code Price Pkg
qtyWeight(1 pce)g (oz)
CC-U 22.5 ADP.01 1SVR430029R0100 118.4
(0.65)
CC-U MAR.01 1SVR366017R0100 100.19
(0.007)
CC-U 22.5 COV.01 1SVR430005R0100 15.2
(0.18)
Analog signal converters - CC-U range
Ordering details - Accessories
2CD
C 2
52 1
87 F
0005
4,5 62,5
60
1011
,5
22,5
.177
”
2.46”
2.36”
.394
”
.886
”
.453
”
2CD
C 2
52 1
85 F
000522,5
68,5
73,5
.886”
2.70
”
.138”.275”
front-to-backsize 107
ADP.01
203A11 8
.315
”
.787” 252
186
F000
5
MAR.01
Sealable cover - COV.01
4
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/18
Analog signal converters - CC-U range
DIP switch settings
*) Detection of input voltage signal
interruptions:
If the input signal circuit is inter-
rupted, the output signal changes
to the adjusted minimum value (low
fail safe) or maximum value (high fail
safe).
If "No fail safe" is configured,
input signal interruptions are not
detected.
4321 5 876
0...8 V
0...20 mA4...20 mA10...50 mA20...4 mA20...0 mA
0...50 mV0...100 mV0...250 mV0...500 mV
0...1 V
0...5 V
-10...+10 V0...125 mV
1...5 V0...10 V
2... 10 V
-11...+11 V
10...0 V100...0 mV0...1 mA
-55...+55 mA
3...4
2...44...50...14...54...2
A...D4...50...17...93...4
5...7
03...4
7...92
2...4
0
24...5A...D
4...6
3
34143
C5183
6
03
82
3
0
25B
5
64
0
0
D
D
0
0
B...F
5...73...4
---
---
B...F
2CD
C 2
82 0
19 F
0203
Switch 1Input
2.5...7.5 V3.33...9.99 V
High fail safe *)
Gain CoarseType
Potentiometer
0...2.5 V
-22.5...+22.5 mV
-0.45...+0.45 mA
Low faile safe *)No fail safe *)
1 2 43 5 6
-10...-2 V-5...-1 V
-8...0 V-4...0 V0...1 mA
0...20 mA4...20 mA0...10 mA
0...800 μA0...8 mA
0...400 μA
125...625 μA
166...833 μA
2...10 mA100...500 μA
0...666 μA0...16 mA
0...5 V0...10 V1...5 V
2...10 V-10...+10 V-5...+5 V-10...0 V-5...0 V
0...8 V0...4 V
2CD
C 2
82 0
20 F
0203
Switch 2Output
1.25...6.25 V
0...6.66 V-10...+3.33 V-5...+1.66 V
-7.5...+2.5 V-3.75...+1.25 V1.66...8.33 V
-6.66...+6.66 V-3.33...+3.33 V
0...0.5 mA0...13.33 mA
2.5...12.5 mA
3.33...16.66 mA
0.2...1 mA
2CD
C 2
82 0
03 F
0204
OFF
Legend
no influence
ON
CC-U/STD CC-U/STDR with relay output
2CD
C 2
82 0
03 F
0204
OFF
Legend
no influence
ON
1 2 43 5 6
0...10 V
0...5 V
0...1 V
-10...+10 V
1...5 V
0...20 mA
4...20 mA
2C
DC
28
2 0
05
F0
20
4
SwitchInput
Output
Closed-circuit principle
Open-circuit principle
*) Detection of input signal
interruptions:
If the input signal circuit
is interrupted, the output
signal changes to the
adjusted minimum value
(low fail safe) or maximum
value (high fail safe).
CC-U/RTD
2CD
C 2
82 0
03 F
0204
OFF
Legend
no influence
ON
1 2 43 5 6 1 2 43 5 6
PT10
PT100
PT1000
0...500 °C0...550 °C0...600 °C0...650 °C0...700 °C0...750 °C0...800 °C0...850 °C0...50 °C0...60 °C0...70 °C0...80 °C0...90 °C
0...100 °C0...200 °C
0...400 °C0...300 °C
0...500 °C0...10 °C0...20 °C0...30 °C0...40 °C0...50 °C0...60 °C
FEDCBA98FEBA983
12
0832100
--
2CD
C 2
82 0
23 F
0203
Type RangeSwitch 1 Switch 2Input
Low fail safe *)High fail safe *)
GainCoarse
1 2 43 5 6
-10...-2 V-5...-1 V
-8...0 V-4...0 V0...1 mA
0...20 mA4...20 mA0...10 mA
0...800 μA0...8 mA
0...400 μA
125...625 μA
166...833 μA
2...10 mA100...500 μA
0...666 μA0...16 mA
0...5 V0...10 V1...5 V
2...10 V-10...+10 V
-5...+5 V-10...0 V-5...0 V
0...8 V0...4 V
2CD
C 2
82 0
24 F
0203
Switch 3Output
1.25...6.25 V
0...6.66 V-10...+3.33 V-5...+1.66 V
-7.5...+2.5 V-3.75...+1.25 V1.66...8.33 V
-6.66...+6.66 V-3.33...+3.33 V
0...0.5 mA0...13.33 mA
2.5...12.5 mA
3.33...16.66 mA
0.2...1 mA
CC-U/RTDR with relay output
2CD
C 2
82 0
03 F
0204
OFF
Legend
no influence
ON
1 2 43 5 60...100 °C0...200 °C0...400 °C0...600 °C0...800 °C
2CD
C 2
82 0
07 F
0204
SwitchInput PT100
Output
Closed-circuit principleOpen-circuit principle
4
4/19 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Analog signal converters - CC-U range
DIP switch settings
CC-U/I
2CD
C 2
82 0
03 F
0204
OFF
Legend
no influence
ON
1 2 43 5 6
-10...-2 V-5...-1 V
-8...0 V-4...0 V0...1 mA0...20 mA4...20 mA0...10 mA
0...800 μA0...8 mA
0...400 μA
125...625 μA
166...833 μA
2...10 mA100...500 μA
0...666 μA0...16 mA
0...5 V0...10 V1...5 V2...10 V
-10...+10 V-5...+5 V-10...0 V-5...0 V
0...8 V0...4 V
2CD
C 2
82 0
29 F
0203
SwitchOutput
1.25...6.25 V
0...6.66 V-10...+3.33 V-5...+1.66 V
-7.5...+2.5 V-3.75...+1.25 V1.66...8.33 V
-6.66...+6.66 V-3.33...+3.33 V
0...0.5 mA0...13.33 mA
2.5...12.5 mA
3.33...16.66 mA
0.2...1 mA
CC-U/V
2CD
C 2
82 0
03 F
0204
OFF
Legend
no influence
ON
1 2 43 5 6
-10...-2 V-5...-1 V
-8...0 V-4...0 V0...1 mA
0...20 mA4...20 mA0...10 mA
0...800 μA0...8 mA
0...400 μA
125...625 μA
166...833 μA
2...10 mA100...500 μA
0...666 μA0...16 mA
0...5 V0...10 V1...5 V
2...10 V-10...+10 V-5...+5 V-10...0 V-5...0 V
0...8 V0...4 V
2CD
C 2
82 0
29 F
0203
SwitchOutput
1.25...6.25 V
0...6.66 V-10...+3.33 V-5...+1.66 V
-7.5...+2.5 V-3.75...+1.25 V1.66...8.33 V
-6.66...+6.66 V-3.33...+3.33 V
0...0.5 mA0...13.33 mA
2.5...12.5 mA
3.33...16.66 mA
0.2...1 mA
*) Detection of input signal
interruptions:
If the input signal circuit is interrupted, the output
signal changes to the adjusted minimum value (low
fail safe) or maximum value (high fail safe).
CC-U/TC
1 2 43 5 6
-10...-2 V-5...-1 V
-8...0 V-4...0 V0...1 mA
0...20 mA4...20 mA0...10 mA
0...800 μA0...8 mA
0...400 μA
125...625 μA
166...833 μA
2...10 mA100...500 μA
0...666 μA0...16 mA
0...5 V0...10 V1...5 V
2...10 V-10...+10 V-5...+5 V-10...0 V-5...0 V
0...8 V0...4 V
2CD
C 2
82 0
17 F
0208
Switch 3Output
1.25...6.25 V
0...6.66 V-10...+3.33 V-5...+1.66 V
-7.5...+2.5 V-3.75...+1.25 V1.66...8.33 V
-6.66...+6.66 V-3.33...+3.33 V
0...0.5 mA0...13.33 mA
2.5...12.5 mA
3.33...16.66 mA
0.2...1 mA
2CD
C 2
82 0
03 F
0204
OFF
Legend
no influence
ON
1 2 43 5 6 1 2 43 5 6
R
B
mV
N
K
J
T
S
E
0-100...900 °C0-250...1350 °C0-100...750 °C0-100...400 °C-150-0...400 °C0-250...1550 °C0-100...700 °C
0-200...1000 °C0-100...650 °C
0-200...1300 °C0-250...1350 °C0-450...1700 °C0-700...1750 °C
0-2...10 mV0-10...50 mV
2CD
C 2
82 0
10 F
0204
Type RangeSwitch 1 Switch 2Input
Low fail safe *)High fail safe *)
CC-U/TCR with relay output
2CD
C 2
82 0
03 F
0204
OFF
Legend
no influence
ON
1 2 43 5 6
S
J
K
T
0...240 °C0...480 °C
0...1200 °C0...250 °C0...500 °C
0...1350 °C-150...+120 °C
0...220 °C0...400 °C0...210 °C0...380 °C0...860 °C
0...1550 °C
2CD
C 2
82 0
04 F
0204
Type RangeSwitchInput
Output
Closed-circuit principleOpen-circuit principle
4
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/20
Pot.G
H
J
2CD
C 2
82 0
15 F
0206
BurdenR � 4.7 k�
BurdenR � 600 �
supply
+ 2.5 V
CC-U/STD
Analog signal converters - CC-U range
Wiring instructions
2CD
C 2
82 0
16 F
0206
Value R1
Value R2
Threshold Hysteresis
supply
CC-U/STDR with relay output
J
H
G
2CD
C 2
82 0
17 F
0206
BurdenR � 4.7 k�
BurdenR � 600 �
supply
CC-U/RTD
υG
J
H
K M
B (22)C (21)A (24)
E (12)F (11)D (14)
R1
R2
2CD
C 2
82 0
45 F
0203
Value R1
Value R2
Threshold Hysteresis
supply
CC-U/RTDR with relay output2C
DC
282
022
F02
06
BurdenR � 4.7 k�
BurdenR � 600 �
supply
CC-U/V
2CD
C 2
82 0
21 F
0206
BurdenR � 4.7 k�
BurdenR � 600 �
supply
CC-U/I
2CD
C 2
82 0
19 F
0206
without cold-junction compensation:
switch SW2.2 = OFF
2CD
C 2
82 0
18 F
0206
BurdenR � 4.7 k�
BurdenR � 600 �
supply
CC-U/TC
2CD
C 2
82 0
20 F
0206
Value R1
Value R2
Threshold Hysteresis
supply
CC-U/TCR with relay output
4
4/21 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Adjustment range
OUT [%]
IN [%]
SW1.4 = +100 %
SW1.5 = +50 %
100
90
80
70
60
50
40
30
20
10
10 20 30 40 50 60 70 80 90 100
�2C
DC
282
018
F02
03
Offset remote poti
SW1.6 = +22.5 %
Gain“gain-coarse”
and“gain-fine”
CC-U/STD
Analog signal converters - CC-U range
Technical information
Function diagrams
Switching points of the output relay depending on the input range, configuration open-circuit principle
OUT
11-14
11-12
21-24
21-22
R1
R2
IN [%]
100
90
80
70
60
50
40
30
20
10
0
2CD
C 2
82 0
21 F
0203
Hysteresis R15-50 % of threshold value R1
Threshold value R12-100 %
of input range
Threshold value R22-100 %
of input range
Hysteresis R25-50 % of threshold value R2
Actua
l valu
e
Switching points
21-2421-22
11-1411-12
R2
R1
2C
DC
28
2 0
44
F0
20
3
R1 Threshold value
R1 Hysteresis
R2 Hysteresis
R2 Threshold value
Input
Closed-circuit principle
21-2421-22
11-1411-12
R2
R1
2C
DC
282 0
46 F
0203
R1 Threshold value
R1 Hysteresis
R2 Hysteresis
R2 Threshold value
Input
Open-circuit principle
CC-U/STDR with relay output
4
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/22
Resistance of PT10, PT100 and PT1000 sensors depending on the temperature
PT1000
PT100
PT10
2CD
C 2
82 0
22 F
0203
Res
ista
nce
[�]
Temperature [°C]
Characteristic curves
Analog signal converters - CC-U range
Technical information
CC-U/RTD
Switching points of the output relay depending on the input range, configuration open-circuit principle
OUT
11-14
11-12
21-24
21-22
R1
R2
100
90
80
70
60
50
40
30
20
10
0
IN [%]
800
700
600
500
400
300
200
100
50 100 150 200 250 300 350 400
2CD
C 2
82 0
25 F
0203
Resistance [�]
Tem
per
atur
e υ
[°C
]
Hysteresis R15-50 % of threshold value R1
Threshold value R12-100 %
of input range
Threshold value R22-100 %
of input range Hysteresis R25-50 % of threshold value R2
Actua
l valu
e
Switching points Function diagrams
21-2421-22
11-1411-12
R2
R1
2C
DC
28
2 0
44
F0
20
3
R1 Threshold value
R1 Hysteresis
R2 Hysteresis
R2 Threshold value
Input
Closed-circuit principle
21-2421-22
11-1411-12
R2
R1
2C
DC
282 0
46 F
0203
R1 Threshold value
R1 Hysteresis
R2 Hysteresis
R2 Threshold value
Input
Open-circuit principle
CC-U/RTDR with relay output
0...100 V0...150 V0...250 V0...300 V0...400 V
0...600 V
0...450 V0...550 V
12345
8
67
2CD
C 2
82 0
12 F
0204
Switchposition
Selecting input range by front-face rotary switch
U(t) [V]
INUeff [V]
OUT [%]
0 50 100
300
0
-300
2CD
C 2
82 0
30 F
0203
Offset �20 %
Gain �15 %resulting
RMS value
operating angle
Example of application
CC-U/V
Input range selection
RMS measurement and conversion of a phase-angle controlled voltage signal L1 = 230 V
4
4/23 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Analog signal converters - CC-U range
Technical information
J H G
J H G
5 A 1 A C
5 A 1 A C
2CD
C 2
82 0
33 F
0203
Select input range by terminals
Input range 1 A
Connected linesUsed terminalsTerminal marking
Input range 5 A
Connected linesUsed terminalsTerminal marking
Input range selection
RMS measurement and conversion of a current signal
I(t) [A]
IN [%]
OUT [%]0 50 100
t
5
4
3
2
1
0
-1
-2
-3
-4
-5
2CD
C 2
82 0
28 F
0203Offset �20 %
Gain �15 %
resulting
RMS value
Example of application
CC-U/I
Thermocouple voltages depending on the temperature
Typ T
Typ N
Typ K
Typ J
Typ E
Typ R
Typ S
Typ B
-250
-200
-150
-100
-50 0 50 100
150
200
250
300
350
400
450
500
550
600
650
700
750
800
850
900
950
1000
1050
1100
1150
1200
1250
1300
1350
1400
1450
1500
1550
1600
1650
1700
1750
1800
80000
75000
70000
65000
60000
55000
50000
45000
40000
35000
30000
25000
20000
15000
10000
5000
0
-5000
-10000
-15000
2CD
C 2
82 0
26 F
0103
Temperatur [°C]
Ther
moe
lem
ent-
Sp
annu
ng [μ
V]
Characteristic curve
CC-U/TC
CC-U/TCR with relay output
Function diagrams
21-2421-22
11-1411-12
R2
R1
2C
DC
28
2 0
44
F0
20
3
R1 Threshold value
R1 Hysteresis
R2 Hysteresis
R2 Threshold value
Input
Closed-circuit principle
21-2421-22
11-1411-12
R2
R1
2C
DC
282 0
46 F
0203
R1 Threshold value
R1 Hysteresis
R2 Hysteresis
R2 Threshold value
Input
Open-circuit principle
Switching points of the output relay depending on the input range, configuration open-circuit principle
Typ T
Typ J
Typ K
Typ S
IN [%]
100
0 OUT
11-14
11-12
21-24
21-22
R1
R2
7000
6500
6000
5500
5000
4500
4000
3500
3000
2500
2000
1500
1000
500
0
-500
-1000
-1500
-275
-175
-75
25
125
225
325
425
525
625
725
825
925
1025
1125
1225
1325
1425
1525
1625
1725
1825
2CD
C 2
82 0
27 F
0203
Temperature [°C]
Ther
moc
oup
le v
olta
ge [μ
V]
Threshold value R2 = 400 °C
Release hysteresis
Threshold value R1 = 1000 °C
Release hysteresis
Switching points
4
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/24
Analog signal converters - CC-U range
Technical data
Type CC-U/STD CC-U/RTD 3) CC-U/TC
Input circuits - Analog inputs J-G-H Current Voltage Potentio-
meter
Temperature sen-
sors
Thermocouples
(IEC 584-1 and 2)Input signal 0-20 mA
4-20 mA10-50 mA0-1 mA
0-100 mV0-1 V0-5 V1-5 V0-10 V2-10 V± 10 V
470 � -1 M� 2)
PT10, PT100, PT1000(IEL 751 and JICC 1604)
TC.KTC.TTC.ETC.R
TC.JTC.STC.NTC.B
Limitation of input signals ± 55 mA ± 11 V - -
Rated input range - - - Max. temperature adjustable: 6-60 °C for PT1000 50-500 °C for PT100 500-850 °C for PT10
refer to temperature specs. of individual thermocouples
Influence of line resistance - - - 0.015 °C/� < 0.01 % / 100 �
Gain adjustment range (universal devices)
0.9-110 mA
45 mV -22 V
- see DIP switch settings
Offset adjustment range (universal devices) -137.5...+62.5 % ± 5 % ± 10 %
Input impedance for different ranges - -
without detection of input signal interruption 51 � 6 M� 3 G� - -
with detection of input signal interruption 51 � 3.5 M� 9.5 G� - -
Suppression at 50 Hz - - - - > 40 dB
Common-mode rejection - - - 120 dB 105 dB
Output circuits - Analog outputs D-F, A-C Current VoltageOutput signal 0-20 mA, 4-20 mA 0-5 V, 1-5 V, 0-10 V, 2-10 V, ± 10 V
Output burden � 600 � � 4.7 K�
Accuracy 1) ±0.1 % of full-scale ±0.2 % of full-scale ±0.1 % of full-scale
Residual ripple - < 0.15 % -
Response time 200 μs 10 ms 200 ms
Transmission frequency 1 kHz 80 Hz 2 Hz (to -3 dB)
Supply circuits K-M DC versions AC versions
Rated supply voltage 24-48 V DC 110-240 V AC
Supply voltage range 24-48 V DC / 24 V AC 110-240 V AC / 100-300 V DC
Supply voltage tolerance DC: -15...+15 % AC: -15...+10 %
Rated frequency 0 Hz or 50/60 Hz
Power consumption 2 W at 24 V DC 4.5 VA at 230 V AC
Indication of operational statesSupply voltage U: green LED
General dataAmbient temperature range operation / storage -20...+60 °C / -40...+80 °C
Temperature coefficient ±150 ppm/°C ±250 ppm/°C ±200 ppm/°C at min. offset±400 ppm/°C at max. offset
Mounting position any
Mounting DIN rail (IEC/EN 60715), snap-on mounting / screw mounting with adapter
Electrical connectionWire size rigid plug-connector with screw terminals 0.2-2.5 mm2 (24-12 AWG)
fine-strand with(out) wire end ferrule plug-connector with screw terminals 0.2-2.5 mm2 (24-12 AWG)
Stripping length 7 mm (0.28 inch)
Tightening torque 0.4 Nm (3.5 ib.in)
Electromagnetic compatibilityInterference immunity EN 61000-6-2
electrostatic discharge (ESD) IEC/EN 61000-4-2 Level 3 (±6 kV / ±8 kV)
electromagnetic field (HF radiation resistance) IEC/EN 61000-4-3 10 V/m
fast transients (Burst) IEC/EN 61000-4-4 Level 3 (±2 kV / 5 kH)
powerful impulses (Surge) IEC/EN 61000-4-5 ±2 kV / ±1 kV
HF line emission IEC/EN 61000-4-6 10 V
Interference emission EN 61000-6-4 Class B
Isolation dataIsolation test (between all isolated circuits) 1.5 kV
Test voltage (between all isolated circuits) 1.5 kV / 50 Hz
1) Includes non-linearity and factory setting, influenced by supply voltage and output load.2) Detection of an input signal break (fail safe) and resistance > 10 k� results in a linearity of �0.2 %.3) When connecting a 2-wire sensor, the terminals J and H have to be jumpered.
Approvals see „Overview“ on page 4/3
4
4/25 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Analog signal converters - CC-U range
Technical data
Type CC-U/STDR CC-U/RTDR 1) CC-U/TCR
Input circuits - Analog inputs J-H Current Voltage Temperature sensors Thermocouples
(IEC 584-1 and 2)Measuring signal / input range 0-20 mA
4-20 mA0-1 V / 1-5 V0-10 / ±10 V
PT100 TC.K, TC.JTC.T, TC.S
Input resistance approx. 50 �
approx. 1.5 M�
Adjustable threshold 2-100 % of selected input range
Adjustable hysteresis 5-50 % of threshold
Repeat accuracy (constant parameters) ±0.5 % of full-scale
Output circuits - Relay outputs E-D-F, B-C-A Relay, 2 c/o contacts
Rated switching voltage 250 V AC
Rated switching current AC-12 (resistive) 230 V 4 A
AC-15 (inductive) 230 V 3 A
DC-12 (resistive) 24 V 4 A
DC-13 (inductive) 24 V 2 A
AC rating (UL 508)
Utilization category (Control Circuit Rating Code) B 300
max. rated operational voltage 300 V AC
max. continuous thermal current at B 300 5 A
max. making/breaking apparent power at B 300 3600/360 VA
Minimum switching voltage 12 V
Minimum switching current / power 10 mA / 0.6 VA (W)
Response time 10 ms
Mechanical lifetime 30 x 106 switching cycles
Electrical lifetime at AC-12, 230 V, 4 A 0.1 Mio. switching cycles
Supply circuits K-M DC versions AC versions
Rated supply voltage 24-48 V DC 110-240 V AC
Supply voltage range 24-48 V DC / 24 V AC 110-240 V AC / 100-300 V DC
Supply voltage tolerance DC: -15...+15 % AC: -15...+10 %
Rated frequency 0 Hz or 50/60 Hz
Power consumption 2 W at 24 V DC 4.5 VA at 230 V AC
Indication of operational statesSupply voltage U: green LED
1st / 2nd output relay energized R1: yellow LED / R2: yellow LED
General dataAmbient temperature range operation / storage -20...+60 °C / -40...+80 °C
Temperature coefficient ±300 ppm/°C
Mounting position any
Mounting DIN rail (IEC/EN 60715), snap-on mounting / screw mounting with adapter
Electrical connectionWire size rigid plug-connector with screw terminals 0.2-2.5 mm2 (24-12 AWG)
fine-strand with(out) wire end ferrule plug-connector with screw terminals 0.2-2.5 mm2 (24-12 AWG)
Stripping length 7 mm (0.28 inch)
Tightening torque 0.4 Nm (3.5 ib.in)
Electromagnetic compatibilityInterference immunity EN 61000-6-2
electrostatic discharge (ESD) IEC/EN 61000-4-2 Level 3 (±6 kV / ±8 kV)
electromagnetic field (HF radiation resistance) IEC/EN 61000-4-3 10 V/m
fast transients (Burst) IEC/EN 61000-4-4 Level 3 (±2 kV / 5 kH)
powerful impulses (Surge) IEC/EN 61000-4-5 ±2 kV / ±1 kV
HF line emission IEC/EN 61000-4-6 10 V
Interference emission EN 61000-6-4 Class B
Isolation dataInsulation voltage (between all isolated circuits) 2.5 kV
Test voltage (between all isolated circuits) 2.5 kV
1) When connecting a 2-wire sensor, the terminals J and H have to be jumpered.
Approvals see „Overview“ on page 4/3
4
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/26
Analog signal converters - CC-U range
Technical data
Type CC-U/I CC-U/V
Input circuits - Analog inputs J-G-H any current signals,
RMS measurement
any voltage signals,
RMS measurementRated input range 0-1 A
0-5 A0-100 V, 0-150V, 0-250 V0-300 V, 0-400 V, 0-450 V0-550 V, 0-600 V
Measuring frequency 0-600 Hz
Overload capacity of inputs input range 1 10 x INom
(10 A) for max. 2 s -
input range 2 10 x INom
(50 A) for max. 2 s -
Gain adjustment range ±15 %
Offset adjustment range ±20 %
Input impedance / resistance 1A: 60 m�, 5 A: 12 m�
> 800 k�
Output circuits - Analog outputs D-F, A-C Current Voltage
Output signal 0-20 mA, 4-20 mA 0-5 V, 1-5 V, 0-10 V, 2-10 V, ± 10 V
Output load � 600 � � 4.7 K�
Accuracy1) ±0.5 % of full-scale
Temperature coefficient ±250 ppm/°C max. ±300 ppm/°C max.
Residual ripple < 0.15 %
Response time 150 ms
Supply circuits K-M DC versions AC versions
Rated supply voltage 24-48 V DC 110-240 V AC
Supply voltage range 24-48 V DC, 24 V AC 110-240 V AC, 100-300 V DC
Supply voltage tolerance DC: -15...+15 % AC: -15...+10 %
Rated frequency 0 Hz or 50/60 Hz
Power consumption 2 W at 24 V DC 4.5 VA at 230 V AC
Indication of operational states
Supply voltage U: green LED
General data
Ambient temperature range operation / storage -20...+60 °C / -40...+80 °C
Mounting position any
Mounting DIN rail (IEC/EN 60715), snap-on mounting / screw mounting with adapter
Electrical connection
Wire size rigid plug-connector with screw terminals 0.2-2.5 mm2 (24-12 AWG)
fine-strand with(out) wire end ferrule plug-connector with screw terminals 0.2-2.5 mm2 (24-12 AWG)
Stripping length 7 mm (0.28 inch)
Tightening torque 0.4 Nm (3.5 lb.in)
Standards
Product standard -
Low Voltage directive 2006/95/EC
EMC directive 2004/108/EC
RoHS directive 2011/65/EC
Electromagnetic compatibility
Interference immunity EN 61000-6-2
electrostatic discharge (ESD) IEC/EN 61000-4-2 Level 3 (±6 kV / ±8 kV)
electromagnetic field (HF radiation resistance) IEC/EN 61000-4-3 10 V/m
fast transients (Burst) IEC/EN 61000-4-4 Level 3 (±2 kV / 5 kH)
powerful impulses (Surge) IEC/EN 61000-4-5 ±2 kV / ±1 kV
HF line emission IEC/EN 61000-4-6 10 V
Interference emission EN 61000-6-4 Class B
Isolation data
Insulation voltage (between all isolated circuits) 1.5 kV
Test voltage (between all isolated circuits) 1.5 kV / 50 Hz
1) Includes non-linearity and factory setting, influenced by supply voltage and output load.
Approvals see „Overview“ on page 4/3
4
4/27 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Analog signal converters - CC-U range
Technical diagr., Connection diagr., Dimensional drawings
.039
J
D F
G
M
H
L K
A C
E
B
2C
DC
28
2 0
23
F0
b0
6
CC-U/x , CC-U/xR
2C
DC
28
2 0
25
F0
b0
6
1.0
0.9
0.8
0.7
0.6
0.5
F
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
cos
2C
DC
282 0
14 F
0b
06
2C
DC
28
2 0
26
F0
b0
6
Dimensional drawings Dimensions in mm and inches
Connection diagram CC-U/xWidth 22.5 mm (0.89 in)
Technical diagramsLoad limit curves CC-U/xxR
Resistive AC load Resistive DC load
Derating curve
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 4/28
4
Analog signal converters
Notes
5
5/1 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Interface relays and optocouplers
Product group picture
5
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/2
Interface relays and optocouplers
Table of contents
Interface Relays and Optocouplers
Pluggable interface relays ................................................................. 5/3
Table of contents 5/4
Benefits and advantages 5/5
Approvals and marks 5/7
Ordering details - CR-S range 5/8
Ordering details - CR-P range 5/9
Ordering details - CR-M range 5/10
Ordering details CR-P/M functional modules 5/13
Ordering details - CR-U range 5/14
Ordering details - CR-U accessories 5/15
Technical data - CR-P, CR-M, CR-U 5/16
Technical data, load limit curves - CR-P, CR-M, CR-U 5/18
Technical data - Sockets for CR-P and CR-M 5/19
Technical data - Sockets for CR-U 5/20
Technical data - CR-S range 5/21
Technical data - CR-S range sockets 5/22
Load limit curves 5/23
Connection diagrams 5/24
Dimensional drawings 5/25
Interface relays and optocouplers R600 range ................................. 5/27
Table of contents 5/28
Benefits and advantages 5/29
Type designators 5/30
Interface relays R600 range ............................................................. 5/31
Benefits and advantages 5/31
Selection 5/33
Ordering details 5/35
Connection diagrams 5/37
Technical data 5/38
General technical data 5/43
Dimensional drawings, Load limit curves 5/44
Optocouplers R600 range ............................................................... 5/45
Selection 5/45
Ordering details 5/47
Connection diagrams 5/48
Technical data 5/49
5
5/3 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Pluggable interface relays
Product group picture
5
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/4
Pluggable interface relays
Table of contents
Pluggable interface relays
Benefits and advantages 5/5
Approvals and marks 5/7
Ordering details - CR-S range 5/8
Ordering details - CR-P range 5/9
Ordering details - CR-M range 5/10
Ordering details CR-P/M functional modules 5/13
Ordering details - CR-U range 5/14
Ordering details - CR-U accessories 5/15
Technical data - CR-P, CR-M, CR-U 5/16
Technical data, load limit curves - CR-P, CR-M, CR-U 5/18
Technical data - Sockets for CR-P and CR-M 5/19
Technical data - Sockets for CR-U 5/20
Technical data - CR-S range 5/21
Technical data - CR-S range sockets 5/22
Load limit curves 5/23
Connection diagrams 5/24
Dimensional drawings 5/25
5
5/5 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Pluggable pcb relays CR-P – 9 different coil voltages
– DC versions: 12 V, 24 V, 48 V, 110 V
– AC versions: 24 V, 48 V, 110 V, 120 V, 230 V
– Output contacts:
– 1 c/o contact (16 A) or
– 2 c/o contacts (8 A)
optionally equipped with gold contacts
– Logical or standard sockets
– Cadmium-free contact material
– Width of socket: 15,5 mm
– Pluggable function modules
– Reverse polarity protection/Free wheeling diode
– LED indication
– RC elements
– Overvoltage protection
Slim relays CR-S – Standard slim relays (5 mm), sockets (6.2 mm) and acces-
sories
– Combination of 9 different rated control supply voltages
possible:
– DC versions: 5 V, 12 V, 24 V
– AC/DC versions: 12 V, 24 V, 48 V, 60 V, 110 V, 230 V
– Output: 1 c/o (SPDT) contacts (6 A), standard and goldpla-
ted contacts
– Cadmium-free contact material
– All sockets with LED
– Screw and spring connection terminals
– Jumper bar (red, black, blue), marker and separator availa-
ble as accessories
Pluggable interface relays
Benefits and advantages
1 Socket
2 Pluggable function module
3 Interface relay
4 Holder
4 Marker label
1 Output contacts
2 Socket
3 Relay holder
4 Marker
4 Interface relay
6 LED green: Control supply voltage applied7 Control supply voltage
1
2
3
4
4
4
3
2
1
4
6
7
5
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/6
Pluggable universal relays CR-U – 12 different coil voltages
– DC versions: 12 V, 24 V, 48 V, 110 V, 125 V, 220 V
– AC versions: 24 V, 48 V, 60 V, 110 V, 120 V, 230 V
– Output contacts
– 2 c/o contacts (10 A) or
– 3 c/o contacts (10 A)
– Integrated test button for manual
actuation and locking of the output
contacts (blue = DC, orange = AC) that can be removed if
necessary
– With or without integrated LED
– Cadmium-free contact material
– Width on socket: 38 mm
– Pluggable function modules
– Reverse polarity protection/Free wheeling diode
– LED indication
– RC elements
– Overvoltage protection
– Multifunction time module
Pluggable miniature relays CR-M – 2 different coil voltages
– DC versions: 12 V, 24 V, 48 V, 60 V, 110 V, 125 V, 220 V
– AC versions: 24 V, 48 V, 110 V, 120 V, 230 V
– Output contacts
– 2 c/o contacts (12 A) or
– 3 c/o contacts (10 A) or
– 4 c/o contacts (6 A)
optionally equipped with gold contacts, LED and free
wheeling diode
– Integrated test button for manual actuation and locking of
the output contacts (blue = DC, orange = AC) that can be
removed if necessary
– With or without integrated LED
– Logical or standard sockets
– Cadmium-free contact material
– Width on socket: 27 mm
– Pluggable function modules
– Reverse polarity protection/Free wheeling diode
– LED indication
– RC elements
– Overvoltage protection
Pluggable interface relays
Benefits and advantages
1 Socket
2 Pluggable function module
3 Interface relay
4 Holder
1 Socket
2 Pluggable function module
3 Interface relay
4 Holder
1 1
2 2
3 3
4
4
5
5/7 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Approvals and marks
� existing
� pendingRelays Sockets Modules
Approvals CR
-S
CR
-P
CR
-M
CR
-U
CR
-S
so
cke
ts
CR
-PL
S
CR
-PS
S
CR
-PLC
CR
-M..
L..
CR
-M..
SS
CR
-M..
SF
CR
-U..
S
CR
-U..
E
CR
-U..
SM
CR
-P/M
CR
-U
G ANSI/UL 508 � � � � � � � � � � � 6)
cG CAN/CSA C22.2 No.14 � � � � �1) � �2) � �3) � � � 6)
F CAN/CSA C22.2 No.14 � � � � �
J VDE � 8) � � 4) � � 8)
R EAC � � � � � � � � � � � � �
P Lloyds Register � 5) �
E CCC � � �
CQC �
L RMRS � � 7) � 7) � � � � � � �
Marks
a CE � � � � � � � � � � � � �
1) except CR-PLSx2) except CR-M...LC3) except CR-U3E4) except 125 V DC devices5) only devices with 4 c/o contacts6) except CR-U61D, CR-U61DV7) except 60 V and 125 V devices8) only relays and sockets with screw terminals
Kinds of socketsStandard sockets - Position of connecting terminals:
Coil connection (A1-A2) on lower socket side, contact
connections (n/o and n/c contacts) on the lower and upper
socket side.
Logical sockets - Position of connecting terminals:
Coil connection (A1-A2) on lower socket side, all contact
connections (common contacts, n/o and n/c contacts) on
upper socket side.
Details see connection diagrams
Kind of connecting terminals
Screw type Spring type Fork type
Pluggable interface relays
Approvals and marks
5
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/8
Pluggable interface relays
Ordering details - CR-S range
Description
The pluggable interface relays of the CR-S Range are used for electrical isolation, amplification
and signal matching between the electronic controlling, e.g. PLC, iPC or field bus systems
and the sensor / actuator level. The CR-S Range combines the flexibility of a modular system
and the ability of switching high currents on a small footprint thus can be used in applications
where space saving is essential.
Ordering details - CR-S range pluggable interface relaysRated control supply voltage
Outputs Contact ratings
Type Order code Price Pkg
qty
Weight(1 pce)kg (lb)
5 V DC1 c/o (SPDT) standard contacts
250 V, 6 A
CR-S005VDC1R 1SVR405501R1010
100.005 (0.011)
12 V DC CR-S012VDC1R 1SVR405501R2010
24 V DC CR-S024VDC1R 1SVR405501R3010
48 V DC CR-S048VDC1R 1SVR405501R4010
60 V DC CR-S060VDC1R 1SVR405501R5010
5 V DC1 c/o (SPDT) gold plated contacts
12 V, 250 mA (3W)1)
CR-S005VDC1RG 1SVR405501R1020
100.005 (0.011)
12 V DC CR-S012VDC1RG 1SVR405501R2020
24 V DC CR-S024VDC1RG 1SVR405501R3020
48 V DC CR-S048VDC1RG 1SVR405501R4020
60 V DC CR-S060VDC1RG 1SVR405501R5020
Ordering details - CR-S range complete interface relays (relay + socket)Rated control supply voltage
Outputs Contact ratings
Type Order code Price Pkg
qty
Weight(1 pce)kg (lb)
24 V AC/DC
1 c/o (SPDT) standard contacts
250 V, 6 A
CR-S024VADC1CRS 1SVR405541R3110
100.03 (0.066)
CR-S024VADC1CRZ 1SVR405541R3210
110 V AC/DCCR-S110VADC1CRS 1SVR405541R6110
CR-S110VADC1CRZ 1SVR405541R6210
230 V AC/DCCR-S230VADC1CRS 1SVR405541R7110
CR-S230VADC1CRZ 1SVR405541R7210
24 V AC/DC
1 c/o (SPDT) gold plated contacts
12 V, 250 mA (3W)1)
CR-S024VADC1CRGS 1SVR405541R3120
100.03 (0.066)
CR-S024VADC1CRGZ 1SVR405541R3220
110 V AC/DCCR-S110VADC1CRGS 1SVR405541R6120
CR-S110VADC1CRGZ 1SVR405541R6220
230 V AC/DCCR-S230VADC1CRGS 1SVR405541R7120
CR-S230VADC1CRGZ 1SVR405541R7220
1) If specified maximum values exceeded, the gold plating is destroyed. The maximum values of the standard contacts are then
valid.
Ordering details - CR-S range socketsRated control supply voltage
Connection type Type Order code Price Pkg
qty
Weight(1 pce)kg (lb)
6-24 V DC Screw CR-S006/024VDC1SS 1SVR405521R1100
100.025 (0.055)
Spring CR-S006/024VDC1SZ 1SVR405521R1200
12-24 V AC/DCScrew CR-S012/024VADC1SS 1SVR405521R3100
Spring CR-S012/024VADC1SZ 1SVR405521R3200
48-60 V AC/DC
Screw CR-S048/060VADC1SS 1SVR405521R5100
Spring CR-S048/060VADC1SZ 1SVR405521R5200
110-125 V AC/DC
Screw CR-S110/125VADC1SS 1SVR405521R6100
Spring CR-S110/125VADC1SZ 1SVR405521R6200
220-240 V AC/DC
Screw CR-S220/240VADC1SS 1SVR405521R7100
Spring CR-S220/240VADC1SZ 1SVR405521R7200
Ordering details - CR-S range accessoriesVersion Type Order code Price Pkg
qty
Weight(1 pce)kg (lb)
Jumper bar 20 pole, blue color CR-SJB20-BLUE 1SVR405598R0700
100.008 (0.018)
Jumper bar 20 pole, red color CR-SJB20-RED 1SVR405598R0800
Jumper bar 20 pole, black color CR-SJB20-BLACK 1SVR405598R0900
Marker block CR-SM 1SNB041391R0610 100.0036 (0.0079)
Separator CR-SSEP 1SVR405599R0000 100.012 (0.026)
CR-S
2C
DC
29
1 0
05
F0
01
4
RS, SS = screw connection type
RZ, SZ = spring connection type
5
5/9 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Pluggable interface relays
Ordering details - CR-P range
Ordering details - CR-P rangeRated control supply voltage
Outputs Contact ratings
Type Order code Price Pkg
qty
Weight(1 pce)
kg (lb)
12 V DC
1 c/o (SPDT) 250 V, 16 A
CR-P012DC1 1SVR405600R4000
100.014 (0.031)
24 V DC CR-P024DC1 1SVR405600R1000
48 V DC CR-P048DC1 1SVR405600R6000
110 V DC CR-P110DC1 1SVR405600R8000
24 V AC CR-P024AC1 1SVR405600R0000
48 V AC CR-P048AC1 1SVR405600R5000
110 V AC CR-P110AC1 1SVR405600R7000
120 V AC CR-P120AC1 1SVR405600R2000
230 V AC CR-P230AC1 1SVR405600R3000
12 V DC
2 c/o (SPDT) 250 V, 8 A
CR-P012DC2 1SVR405601R4000
100.014 (0.031)
24 V DC CR-P024DC2 1SVR405601R1000
48 V DC CR-P048DC2 1SVR405601R6000
110 V DC CR-P110DC2 1SVR405601R8000
24 V AC CR-P024AC2 1SVR405601R0000
48 V AC CR-P048AC2 1SVR405601R5000
110 V AC CR-P110AC2 1SVR405601R7000
120 V AC CR-P120AC2 1SVR405601R2000
230 V AC CR-P230AC2 1SVR405601R3000
Ordering details - AccessoriesVersion Connection
terminalType Order code Price Pkg
qty
Weight(1 pce)
kg (lb)
Logical socket with protective separation
screw CR-PLS 1SVR405650R0000
10
0.045 (0.099)
Logical socket
screw CR-PLSx 1SVR405650R01000.043 (0.095)
spring CR-PLC 1SVR405650R02000.042 (0.093)
Standard socket screw CR-PSS 1SVR405650R10000.038 (0.084)
Plastic holder for socket CR-PH 1SVR405659R0000
10
0.002 (0.004)
Jumper bar for sockets with screw connection
CR-PJ 1SVR405658R50000.018 (0.040)
Marker CR-PM 1SVR405658R0000 100.0002 (0.0004)
2C
DC
29
1 0
04
F0
00
72
CD
C 2
91
00
6 F
00
11
CR-PLS
CR-P
CR-PJ
2C
DC
29
1 0
45
F0
00
4
Ordering details - CR-P range with gold contactsRated control supply voltage
Outputs Contact ratings
Type Order code Price Pkg
qty
Weight(1 pce)
kg (lb)
24 V DC
2 c/o (SPDT) gold contact
250 V, 8 A
CR-P024DC2 1SVR405606R1000
100.014 (0.031)
24 V AC CR-P024AC2G 1SVR405606R0000
110 V AC CR-P110AC2G 1SVR405606R7000
230 V AC CR-P230AC2G 1SVR405606R3000
5
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/10
Pluggable interface relays
Ordering details - CR-M range
Ordering details - CR-M range without LEDRated control supply voltage
Outputs Contact ratings
Type Order code Price Pkg
qty
Weight(1 pce)
kg (lb)
12 V DC
2 c/o (SPDT) 250 V, 12 A
CR-M012DC2 1SVR405611R4000
100.033 (0.073)
24 V DC CR-M024DC2 1SVR405611R1000
48 V DC CR-M048DC2 1SVR405611R6000
60 V DC CR-M060DC2 1SVR405611R4200
110 V DC CR-M110DC2 1SVR405611R8000
125 V DC CR-M125DC2 1SVR405611R8200
220 V DC CR-M220DC2 1SVR405611R9000
24 V AC CR-M024AC2 1SVR405611R0000
48 V AC CR-M048AC2 1SVR405611R5000
110 V AC CR-M110AC2 1SVR405611R7000
120 V AC CR-M120AC2 1SVR405611R2000
230 V AC CR-M230AC2 1SVR405611R3000
12 V DC
3 c/o (SPDT) 250 V, 10 A
CR-M012DC3 1SVR405612R4000
100.033 (0.073)
24 V DC CR-M024DC3 1SVR405612R1000
48 V DC CR-M048DC3 1SVR405612R6000
60 V DC CR-M060DC3 1SVR405612R4200
110 V DC CR-M110DC3 1SVR405612R8000
125 V DC CR-M125DC3 1SVR405612R8200
220 V DC CR-M220DC3 1SVR405612R9000
24 V AC CR-M024AC3 1SVR405612R0000
48 V AC CR-M048AC3 1SVR405612R5000
60 V AC CR-M060AC3 1SVR405612R5200
110 V AC CR-M110AC3 1SVR405612R7000
120 V AC CR-M120AC3 1SVR405612R2000
230 V AC CR-M230AC3 1SVR405612R3000
12 V DC
4 c/o (SPDT) 250 V, 6 A
CR-M012DC4 1SVR405613R4000
100.033 (0.073)
24 V DC CR-M024DC4 1SVR405613R1000
48 V DC CR-M048DC4 1SVR405613R6000
60 V DC CR-M060DC4 1SVR405613R4200
110 V DC CR-M110DC4 1SVR405613R8000
125 V DC CR-M125DC4 1SVR405613R8200
220 V DC CR-M220DC4 1SVR405613R9000
24 V AC CR-M024AC4 1SVR405613R0000
48 V AC CR-M048AC4 1SVR405613R5000
110 V AC CR-M110AC4 1SVR405613R7000
120 V AC CR-M120AC4 1SVR405613R2000
230 V AC CR-M230AC4 1SVR405613R3000
CR-M
2C
DC
29
1 0
02
F0
01
5
5
5/11 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Pluggable interface relays
Ordering details - CR-M range
Ordering details - CR-M range with LEDRated control supply voltage
Outputs Contact ratings
Type Order code Price Pkg
qty
Weight(1 pce)
kg (lb)
12 V DC
2 c/o (SPDT) 250 V, 12 A
CR-M012DC2L 1SVR405611R4100
100.033 (0.073)
24 V DC CR-M024DC2L 1SVR405611R1100
48 V DC CR-M048DC2L 1SVR405611R6100
60 V DC CR-M060DC2L 1SVR405611R4300
110 V DC CR-M110DC2L 1SVR405611R8100
125 V DC CR-M125DC2L 1SVR405611R8300
220 V DC CR-M220DC2L 1SVR405611R9100
24 V AC CR-M024AC2L 1SVR405611R0100
48 V AC CR-M048AC2L 1SVR405611R5100
110 V AC CR-M110AC2L 1SVR405611R7100
120 V AC CR-M120AC2L 1SVR405611R2100
230 V AC CR-M230AC2L 1SVR405611R3100
12 V DC
3 c/o (SPDT) 250 V, 10 A
CR-M012DC3L 1SVR405612R4100
100.033 (0.073)
24 V DC CR-M024DC3L 1SVR405612R1100
48 V DC CR-M048DC3L 1SVR405612R6100
60 V DC CR-M060DC3L 1SVR405612R4300
110 V DC CR-M110DC3L 1SVR405612R8100
125 V DC CR-M125DC3L 1SVR405612R8300
220 V DC CR-M220DC3L 1SVR405612R9100
24 V AC CR-M024AC3L 1SVR405612R0100
48 V AC CR-M048AC3L 1SVR405612R5100
110 V AC CR-M110AC3L 1SVR405612R7100
120 V AC CR-M120AC3L 1SVR405612R2100
230 V AC CR-M230AC3L 1SVR405612R3100
12 V DC
4 c/o (SPDT) 250 V, 6 A
CR-M012DC4L 1SVR405613R4100
100.033 (0.073)
24 V DC CR-M024DC4L 1SVR405613R1100
48 V DC CR-M048DC4L 1SVR405613R6100
60 V DC CR-M060DC4L 1SVR405613R4300
110 V DC CR-M110DC4L 1SVR405613R8100
125 V DC CR-M125DC4L 1SVR405613R8300
220 V DC CR-M220DC4L 1SVR405613R9100
24 V AC CR-M024AC4L 1SVR405613R0100
48 V AC CR-M048AC4L 1SVR405613R5100
110 V AC CR-M110AC4L 1SVR405613R7100
120 V AC CR-M120AC4L 1SVR405613R2100
230 V AC CR-M230AC4L 1SVR405613R3100
Ordering details - CR-M range with LED and free-wheeling diodeRated control supply voltage
Outputs Contact ratings
Type Order code Price Pkg
qty
Weight(1 pce)kg (lb)
24 V DC 4 c/o (SPDT) 250 V, 6 A CR-M024DC4LD 1SVR405614R1100 100.033 (0.073)
Ordering details - CR-M range with gold contactsRated control supply voltage
Outputs Contact ratings
Type Order code Price Pkg
qty
Weight(1 pce)kg (lb)
24 V DC
4 c/o (SPDT) 250 V, 6 A
CR-M024DC4G 1SVR405618R1000
100.033 (0.073)
24 V AC CR-M024AC4G 1SVR405618R0000
110 V AC CR-M110AC4G 1SVR405618R7000
230 V AC CR-M230AC4G 1SVR405618R3000
CR-M
2C
DC
29
1 0
02
F0
01
5
5
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/12
Pluggable interface relays
Ordering details - CR-M range
Rated control supply voltage
Outputs Contact ratings
Type Order code Price Pkg
qty
Weight(1 pce)
kg (lb)
12 V DC
4 c/o (SPDT)250 V / 6 A
CR-M012DC4LG 1SVR405618R4100
100.033 (0.073)
24 V DC CR-M024DC4LG 1SVR405618R1100
48 V DC CR-M048DC4LG 1SVR405618R6100
60 V DC CR-M060DC4LG 1SVR405618R4300
110 V DC CR-M110DC4LG 1SVR405618R8100
125 V DC CR-M125DC4LG 1SVR405618R8300
220 V DC CR-M220DC4LG 1SVR405618R9100
24 V AC CR-M024AC4LG 1SVR405618R0100
100.033 (0.073)
48 V AC CR-M048AC4LG 1SVR405618R5100
110 V AC CR-M110AC4LG 1SVR405618R7100
120 V AC CR-M120AC4LG 1SVR405618R2100
230 V AC CR-M230AC4LG 1SVR405618R3100
Rated control supply voltage
Outputs Contact ratings
Type Order code Price Pkg
qty
Weight(1 pce)
kg (lb)
12 V DC
4 c/o (SPDT)
CR-M012DC4LDG 1SVR405618R4400
100.033 (0.073)
24 V DC CR-M024DC4LDG 1SVR405618R1400
Ordering details - AccessoriesVersion Connection
terminalType Order code Price Pkg
qty
Weight(1 pce)
kg (lb)
Logical socket for 2 c/o
screw
CR-M2LS 1SVR405651R1100
10
0.055 (0.121)
Logical socket for 3 c/o CR-M3LS 1SVR405651R21000.062 (0.137)
Logical socket for 2/4 c/o CR-M4LS 1SVR405651R3100 0.066 (0.146)
Logical socket for 2 c/o
spring
CR-M2LC 1SVR405651R120010
0.065 (0.143)
Logical socket for 2/4 c/o CR-M4LC 1SVR405651R3200 0.066 (0.146)
Standard socket for 2 c/o
screw
CR-M2SS 1SVR405651R1000
10
0.066 (0.146)
Standard socket for 3 c/o CR-M3SS 1SVR405651R20000.068 (0.150)
Standard socket for 2/4 c/o CR-M4SS 1SVR405651R3000 0.070 (0.154)
Standard socket for 2 c/o
fork type
CR-M2SF 1SVR405651R130010
0.040 (0.088)
Standard socket for 2/4 c/o CR-M4SF 1SVR405651R3300 0.048 (0.106)
Plastic holder CR-MH 1SVR405659R1000 100.003 (0.007)
Metal holder CR-MH1 1SVR405659R1100 100.0005 (0.001)
Jumper bar for sockets with screw connection
CR-MJ 1SVR405658R6000 100.029 (0.064)
Marker CR-MM 1SVR405658R1000 100.0005 (0.001)
2C
DC
29
1 0
09
F0
01
12
CD
C 2
91
00
5 F
00
07
CR-M4SS
CR-MJ
Ordering details – CR-M range with gold contacts and LED
Ordering details – CR-M range with gold contacts, LED and free-wheeling diode
CR-M
2C
DC
29
1 0
02
F0
01
5
5
5/13 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Pluggable interface relays
Ordering details CR-P/M functional modules
Ordering details - CR-P/M range (all products stocked)
Rated control supply voltage
Description Version Type Order code Price Pkg
qty
Weight(1 pce)
kg (lb)
6-220 V DC
Diode - Reverse polarity protection/free wheeling diode
A1+, A2- CR-P/M 22 1SVR405651R0000 100.003 (0.007)
6-24 V DCDiode and LED - Reverse polarity protection/free wheeling diode
red, A1+, A2- CR-P/M 42 1SVR405652R0000
100.003 (0.007)
green, A1+, A2- CR-P/M 42V 1SVR405652R1000
24-60 V DCred, A1+, A2- CR-P/M 42B 1SVR405652R4000
green, A1+, A2- CR-P/M 42BV 1SVR405652R4100
110-230 V DCred, A1+, A2- CR-P/M 42C 1SVR405652R9000
green, A1+, A2- CR-P/M 42CV 1SVR405652R9100
6-24 V AC/DC
Spark quenching
CR-P/M 52B 1SVR405653R0000
100.003 (0.007)
24-60 V AC/DC CR-P/M 52D 1SVR405653R4000
110-230 V AC/DC
CR-P/M 52C 1SVR405653R1000
6-24 V AC/DC
Diode, LED and reverse polarity protection
red, for DC A1+, A2-
CR-P/M 62 1SVR405654R0000
100.003 (0.007)
green, for DC A1+, A2-
CR-P/M 62V 1SVR405654R1000
24-60 V AC/DC
red, for DC A1+, A2-
CR-P/M 62E 1SVR405654R4000
green, for DC A1+, A2-
CR-P/M 62EV 1SVR405654R4100
110 V DC 110-230 V AC
red, for DC A1+, A2-
CR-P/M 92 1SVR405654R0100
green, for DC A1+, A2-
CR-P/M 92V 1SVR405654R1100
6-24 V AC/DC
Varistor and LED Overvoltage protection
red, for DC A1+, A2-
CR-P/M 62C 1SVR405655R0000
100.003 (0.007)
green, for DC A1+, A2-
CR-P/M 62CV 1SVR405655R1000
24-60 V AC/DC
red, for DC A1+, A2-
CR-P/M 62D 1SVR405655R4000
green, for DC A1+, A2-
CR-P/M 62DV 1SVR405655R4100
110 V DC 110-230 V AC
red, for DC A1+, A2-
CR-P/M 92C 1SVR405655R0100
green, for DC A1+, A2-
CR-P/M 92CV 1SVR405655R1100
24 V ACOvervoltage protection
CR-P/M 72 1SVR405656R0000
100.002 (0.004)
115 V AC CR-P/M 72A 1SVR405656R1000
230 V AC CR-P/M 82 1SVR405656R2000
Connection diagrams
2C
DC
29
2 0
13
F0
00
5
CR-P/M 22
2C
DC
29
2 0
14
F0
00
5
CR-P/M 42, CR-P/M 42B,
CR-P/M 42C, CR-P/M 42V,
CR-P/M 42BV, CR-P/M 42CV
2C
DC
29
2 0
15
F0
00
5
CR-P/M 52B, CR-P/M 52C
CR-P/M 52D,
2C
DC
292 0
16 F
0005
CR-P/M 62, CR-P/M 62E,
CR-P/M 92, CR-P/M 62V,
CR-P/M 62EV, CR-P/M 92V
2C
DC
292 0
17 F
0005
CR-P/M 62C, CR-P/M 62D,
CR-P/M 92C, CR-P/M 62CV,
CR-P/M 62DV CR-P/M 92CV
2C
DC
292 0
18 F
0005
CR-P/M 72, CR-P/M 82
CR-P/M 72A,
CR-P/M ...
2CD
C 2
91 0
05 S
0011
5
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/14
Pluggable interface relays
Ordering details - CR-U range
DescriptionInterface relays are widely used in various industrial applications:
As an interface they link the electronic controlling, e.g. PLC (programmable logic controller),
PC or field bus systems, to the sensor / actuator level. Here, they take on various functions:
Switching of AC or DC loads with different resistive, inductive and capacitive parts, switching
voltages from a few mV up to 250 V, switching currents from a few mA up to 16 A, amplifica-
tion of weak control signals, electrical isolation of control and load circuits, and signal multi-
plying. In contrast to electronic switching devices, interface relays don’t use additional internal
protective circuits and thus are overload-proof against short-time variations like current or
voltage peaks.
Ordering details - CR-U range without LEDRated control supply voltage
Outputs Contact ratings
Type Order code Price Pkg
qty
Weight(1 pce)kg (lb)
12 V DC
2 c/o (SPDT) 250 V, 10 A
CR-U012DC2 1SVR405621R4000
100.083 (0.183)
24 V DC CR-U024DC2 1SVR405621R100048 V DC CR-U048DC2 1SVR405621R6000110 V DC CR-U110DC2 1SVR405621R8000220 V DC CR-U220DC2 1SVR405621R900024 V AC CR-U024AC2 1SVR405621R000048 V AC CR-U048AC2 1SVR405621R5000110 V AC CR-U110AC2 1SVR405621R7000120 V AC CR-U120AC2 1SVR405621R2000230 V AC CR-U230AC2 1SVR405621R300012 V DC
3 c/o (SPDT) 250 V, 10 A
CR-U012DC3 1SVR405622R4000
100.083 (0.183)
24 V DC CR-U024DC3 1SVR405622R100048 V DC CR-U048DC3 1SVR405622R6000110 V DC CR-U110DC3 1SVR405622R8000125 V DC CR-U125DC3 1SVR405622R8200220 V DC CR-U220DC3 1SVR405622R900024 V AC CR-U024AC3 1SVR405622R000048 V AC CR-U048AC3 1SVR405622R500060 V AC CR-U060AC3 1SVR405622R5200110 V AC CR-U110AC3 1SVR405622R7000120 V AC CR-U120AC3 1SVR405622R2000230 V AC CR-U230AC3 1SVR405622R3000
Ordering details - CR-U range with LEDRated control supply voltage
Outputs Contact ratings
Type Order code Price Pkg
qty
Weight(1 pce)kg (lb)
12 V DC
2 c/o (SPDT) 250 V, 10 A
CR-U012DC2L 1SVR405621R4100
100.083 (0.183)
24 V DC CR-U024DC2L 1SVR405621R110048 V DC CR-U048DC2L 1SVR405621R6100110 V DC CR-U110DC2L 1SVR405621R8100220 V DC CR-U220DC2L 1SVR405621R910024 V AC CR-U024AC2L 1SVR405621R010048 V AC CR-U048AC2L 1SVR405621R5100110 V AC CR-U110AC2L 1SVR405621R7100120 V AC CR-U120AC2L 1SVR405621R2100230 V AC CR-U230AC2L 1SVR405621R310012 V DC
3 c/o (SPDT) 250 V, 10 A
CR-U012DC3L 1SVR405622R4100
100.083 (0.183)
24 V DC CR-U024DC3L 1SVR405622R110048 V DC CR-U048DC3L 1SVR405622R6100110 V DC CR-U110DC3L 1SVR405622R8100220 V DC CR-U220DC3L 1SVR405622R910024 V AC CR-U024AC3L 1SVR405622R010048 V AC CR-U048AC3L 1SVR405622R5100110 V AC CR-U110AC3L 1SVR405622R7100120 V AC CR-U120AC3L 1SVR405622R2100230 V AC CR-U230AC3L 1SVR405622R3100
CR-U
CR-U2S
2C
DC
29
1 0
47
F0
00
4
2C
DC
29
1 0
07
S0
01
1
Ordering details - AccessoriesVersion Type Order code Price Pkg
qty
Weight(1 pce)kg (lb)
Socket for 2 c/o and module CR-U2S 1SVR405670R0000
10
Socket for 3 c/o and module CR-U3S 1SVR405660R0000
Socket for 3 c/o CR-U3E 1SVR405660R0100
Socket small for 2 c/o CR-U2SM 1SVR405670R1100
Socket small for 3 c/o CR-U3SM 1SVR405660R1100
Holder for CR-U socket CR-UH 1SVR405669R0000
5
5/15 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Ordering details - CR-U range (all products stocked)Rated control supply voltage
Description Version Type Order code Price Pkg
qty
Weight(1 pce)
kg (lb)
6-220 V DC
Diode - Reverse polarity protection/free wheeling diode
A1+, A2- CR-U 21 1SVR405661R0000 100.007 (0.015)
6-24 V DCDiode and LED - Reverse polarity protection/free wheeling diode
red, A1+, A2- CR-U 41 1SVR405662R0000
100.007 (0.015)
green, A1+, A2- CR-U 41V 1SVR405662R1000
24-60 V DCred, A1+, A2- CR-U 41B 1SVR405662R4000
green, A1+, A2- CR-U 41BV 1SVR405662R4100
110 V DCred, A1+, A2- CR-U 41C 1SVR405662R9000
green, A1+, A2- CR-U 41CV 1SVR405662R9100
6-24 V AC/DC
Spark quen-ching
CR-U 51B 1SVR405663R0000
100.007 (0.015)
24-60 V AC/DC CR-U 51D 1SVR405663R4000
110-230 V AC/DC
CR-U 51C 1SVR405663R1000
6-24 V AC/DC
Diode and LED
red, for DC A1+, A2-
CR-U 61 1SVR405664R0000
100.007 (0.015)
green, for DC A1+, A2-
CR-U 61V 1SVR405664R1000
24-60 V AC/DC
red, for DC A1+, A2-
CR-U 61E 1SVR405664R4000
green, for DC A1+, A2-
CR-U 61EV 1SVR405664R4100
110 V DC 110-230 V AC
red, for DC A1+, A2-
CR-U 91 1SVR405664R0100
green, for DC A1+, A2-
CR-U 91V 1SVR405664R1100
6-24 V AC/DC
Varistor and LED Overvoltage protection
red, for DC A1+, A2-
CR-U 61C 1SVR405665R0000
100.007 (0.015)
green, for DC A1+, A2-
CR-U 61CV 1SVR405665R1000
24-60 V AC/DC
red, for DC A1+, A2-
CR-U 61D 1SVR405665R4000
green, for DC A1+, A2-
CR-U 61DV 1SVR405665R4100
110 V DC 110-230 V AC
red, for DC A1+, A2-
CR-U 91C 1SVR405665R0100
green, for DC A1+, A2-
CR-U 91CV 1SVR405665R1100
24 V ACOvervoltage protection, varistor
CR-U 71 1SVR405666R0000
100.007 (0.015)
115 V AC CR-U 71A 1SVR405666R1000
230 V AC CR-U 81 1SVR405666R2000
24-240 V AC/DC
Multifunction time module
pluggable onto CR-U2S and CR-U3S
CR-U T 1SVR405667R0000 100.014 (0.031)
CR-U...
2C
DC
29
1 0
04
S0
01
1
2C
DC
29
1 0
32
F0
00
5
Pluggable interface relays
Ordering details - CR-U accessories
CR-U T
Connection diagrams
2C
DC
29
2 0
13
F0
00
5
CR-U 21
2C
DC
29
2 0
14
F0
00
5
CR-U 41, CR-U 41B, CR-U 41C, CR-U 41V, CR-U 41BV, CR-U 41CV
2C
DC
29
2 0
15
F0
00
5
CR-U 51B, CR-U 51C CR-U 51D
2C
DC
292 0
16 F
0005
CR-U 61, CR-U 61E, CR-U 91, CR-U 61V, CR-U 61EV, CR-U 91V
2C
DC
292 0
17 F
0005
CR-U 61C, CR-U 61CV, CR-U 61D, CR-U 61DV, CR-U 91C, CR-U 91CV
2C
DC
292 0
18 F
0005
CR-U 71, CR-U 71A , CR-U 81
All CR-U modules can be plugged onto sockets CR-U2S and CR-U3S.
5
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/16
Pluggable interface relays
Technical data - CR-P, CR-M, CR-U
Input circuit - coil data
Rated control supply voltage US
Rated frequency
Make voltage (at 20 °C)
Maximum-voltage (at 55 °C)
Break voltage
Rated power Coil re-sistance (at 20 °C)
Tolerance of coil resistance
DC coils 12 V DC - 8.4 V DC 30.6 V DC � 0.1 US
0.4-0.48 W 360 � � 10%
24 V DC - 16.8 V DC 61.2 V DC � 0.1 US
0.4-0.48 W 1440 � � 10%
48 V DC - 33.6 V DC 122.4 V DC � 0.1 US
0.4-0.48 W 5700 � � 10%
110 V DC - 77 V DC 280 V DC � 0.1 US
0.4-0.48 W 25200 � � 10%
AC coils 24 V AC 50 / 60 Hz 19.2 V AC 28.8 V AC � 0.15 US
0.75 VA 400 � � 10%
48 V AC 50 / 60 Hz 38.4 V AC 57.6 V AC � 0.15 US
0.75 VA 1550 � � 10%
110 V AC 50 / 60 Hz 88 V AC 132 V AC � 0.15 US
0.75 VA 8900 � � 10%
120 V AC 50 / 60 Hz 96 V AC 144 V AC � 0.15 US
0.75 VA 10200 � � 10%
230 V AC 50 / 60 Hz 184 V AC 276 V AC � 0.15 US
0.75 VA 38500 � � 10%
CR-P range
CR-M range
Rated control supply voltage US
Rated frequency
Make voltage (at 20 °C)
Maximum voltage (at 55 °C)
Break voltage
Rated power Coil resis-tance (at 20 °C)
Tolerance of coil resistance
DC coils 12 V DC - 9.6 V DC 13.2 V DC � 0.1 US
0.9 W 160 � � 10%
24 V DC - 19.2 DC 26.4 V DC � 0.1 US
0.9 W 640 � � 10%
48 V DC - 38.4 V DC 52.8 V DC � 0.1 US
0.9 W 2600 � � 10%
60 V DC - 48 V DC 66 V DC � 0.1 US
0.9 W 4000 � � 10%
110 V DC - 88 V DC 121 V DC � 0.1 US
0.9 W 13600 � � 10%
125 V DC - 100 V DC 137.5 V DC � 0.1 US
0.9 W 16000 � � 10%
220 V DC - 176 V DC 242 V DC � 0.1 US
0.9 W 54000 � � 10%
AC coils 24 V AC 50 / 60 Hz 19.2 V AC 26.4 V AC � 0.2 US
1.6 VA 158 � � 10%
48 V AC 50 / 60 Hz 38.4 V AC 52.8 V AC � 0.2 US
1.6 VA 640 � � 10%
60 V AC 50 / 60 Hz 48 V AC 66 V AC � 0.2 US
1.6 VA 930 � � 10%
110 V AC 50 / 60 Hz 88 V AC 121 V AC � 0.2 US
1.6 VA 3450 � � 10%
120 V AC 50 / 60 Hz 96 V AC 132 V AC � 0.2 US
1.6 VA 3770 � � 10%
230 V AC 50 / 60 Hz 184 V AC 253 V AC � 0.2 US
1.6 VA 16100 � � 10%
Rated control supply voltage US
Rated frequency
Make voltage (at 20 °C)
Maximum voltage (at 55 °C)
Break voltage
Rated power Coil re-sistance (at 20 °C)
Tolerance of coil resistance
DC coils 12 V DC - 9.6 V DC 13.2 V DC � 0.1 Us 1.5 W 110 � � 10 %
24 V DC - 19.2 V DC 26.4 V DC � 0.1 Us 1.5 W 430 � � 10 %
48 V DC - 38.4 V DC 52.8 V DC � 0.1 Us 1.5 W 1750 � � 10 %
110 V DC - 88.0 V DC 121.0 V DC � 0.1 Us 1.5 W 9200 � � 10 %
125 V DC - 100 V DC 137.5 V DC � 0.1 Us 1.5 W 11000 � � 10 %
220 V DC - 176.0 V DC 242.0 V DC � 0.1 Us 1.5 W 37000 � � 10 %
AC coils 24 V AC 50 / 60 Hz 19.2 V AC 26.4 V AC � 0.15 US
2.8 VA (50 Hz)2.5 VA (60 Hz)
75 � � 10 %
48 V AC 50 / 60 Hz 38.4 V AC 52.8 V AC � 0.15 US
2.8 VA (50 Hz)2.5 VA (60 Hz)
305 � � 10 %
60 V AC 50 / 60 Hz 48.0 V AC 66.0 V AC � 0.15 US
2.8 VA (50 Hz)2.5 VA (60 Hz)
475 � � 10 %
110 V AC 50 / 60 Hz 88.0 V AC 121.0 V AC � 0.15 US
2.8 VA (50 Hz)2.5 VA (60 Hz)
1700 � � 10 %
120 V AC 50 / 60 Hz 96.0 V AC 132.0 V AC � 0.15 US
2.8 VA (50 Hz)2.5 VA (60 Hz)
1910 � � 10 %
230 V AC 50 / 60 Hz 184.0 V AC 253.0 V AC � 0.15 US
2.8 VA (50 Hz)2.5 VA (60 Hz)
7080 � � 10 %
CR-U range
5
5/17 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Type CR-P...1 CR-P...2 CR-M...2 CR-M...3 CR-M...4 CR-U...2 CR-U...3
Output circuit(s) 11-12/1411-12/14 21-22/24
11-12/1421-22/24
11-12/1421-22/2431-32/34
11-12/1421-22/2431-32/3441-42/44
11-12/1431-32/34
11-12/1421-22/2431-32/34
Kind of output Relay, 1 c/o Relay, 2 c/o Relay, 2 c/o Relay, 3 c/o Relay, 4 c/o Relay, 2 c/o Relay, 3 c/o
Contact material AgNiAgNi AgNi/Au 5 μm
AgNi AgNiAgNi AgNi/Au 5 μm
AgNi
Rated operational voltage Ue (VDE 0110, IEC 60947-1) 250 V
Minimum switching voltage 5 V 10 V (AgNi); 5 V (AgNi/Au) 10 V
Maximum switching voltage DC 300 V DC 250 V DC
AC 440 V AC 250 V AC 440 V AC
Minimum switching current 5 mA (AgNi), 2 mA (AgNi/Au) 5 mA (AgNi) 5 mA (AgNi) 2 mA (AgNi/Au) 5 mA
Rated free air thermal current Ith
16 A 8 A 12 A 10 A 6 A 10 A
Rated operationalcurrent (IEC 60947-5-1)
AC-12 (resistive) 230 V 16 A 8 A 12 A 10 A 6 A 10 AAC-15 (inductive) 230 V 1.5 A 1.5 A 1.5 A 1.5 A 1 A 1.5 AAC-15 (inductive) 120 V 3 A 1.5 A 3 A
DC-12 (resistive) 24 V 16 A 8 A 12 A 10 A 6 A 10 A DC-13 (inductive) 24 V 2.5 A 2 A 2.5 A 2.5 A 2 A 2 A
DC-13 (inductive) 120 V 0.22 ADC-13 (inductive) 250 V 0.1 A
AC rating (UL 508)
Utilization category (pilot duty)(Contact rating code designation)
B300 B300 B300
max. rated operational voltage 300 V AC 300 V AC 300 V AC
Max. continuous thermal currentat utilization category
5 A 5 A 5 A 2.5 A 5 A
Max. making / breaking apparentpower at utilization category
3600 / 360 VA 3600 / 360 VA1800 / 180 VA
3600/360 VA
Utilization category (resistive)(CSA22.2 No.14....)
16 A, 250 V AC
8 A, 250 V AC
10 A, 250 V AC12 A, 150 V AC
6 A, 250 V AC10 A, 150 V AC
5 A, 250 V AC10 A, 150 V AC
10 A, 250 V AC (resistive + single-phase)
DC rating *
(UL 508; NEMA ICS-5)
Utilization category (pilot duty)(Contact rating code designation)
R300
Max. rated operational voltage 300 V DC
Max. continuous thermal currentat utilization category
1 A
Max. making / breaking apparent power at utilization category
28 VA
Utilization category (resistive)(CSA22.2 No.14....)
- 10 A, 24 V DC - 10 A, 28 V DC
Maximum making (inrush) current 30 A 15 A 24 A 20 A 12 A 20 A
Minimum switching power 0.3 W (AgNi), 0.05 W (AgNi/Au) 0.3 W (AgNi), 0.1 W (AgNi/Au) 0.3 W
Maximum switching (breaking) power
AC1 (resistive)4000 VA 2000 VA 3000 VA 2500 VA 1500 VA 2500 VA
Contact resistance � 100 m�
Maximum operating frequency
rated load AC-1 600 switching cycles/h 1200 switching cycles/h
without load 72000 switching cycles/h 18000 switching cycles/h 12000 switching cycles/h
Mechanical lifetime > 3 x 107 switching cycles > 2 x 107 switching cycles
Electrical lifetime electrical AC1 (resistive)
> 0.7 x 105
switching cycles (16 A, 250 V)
> 105
switching cycles (8 A, 250 V)
> 105 switching cycles
> 105 switching cycles (12 A, 250 V)(12 A, 250 V) (10 A, 250 V) (6 A, 250 V)
cos see reduction factor F
Response time typ. 7 ms typ. 13 ms (DC),10 ms (AC) typ. 18 ms (DC), 12 ms (AC)
Release time typ. 3 ms typ. 3 ms (DC), 8 ms (AC) typ. 7 ms (DC), 10 ms (AC)
Isolation data
Rated insulation voltage 400 V AC 250 V AC
Insulation class C250 / B400 C250 / B250 C250
Rated impulsewithstand voltage U
imp
between coil and contacts 5 kV AC 2.5 kV AC
between open contacts 1 kV AC 1.5 kV AC
between c/o (SPDT) contacts - 2.5 kV AC 2.5 kV AC � 2 kV AC 2 kV AC
Clearance between coil and contacts � 10 mm � 2.5 mm � 1.6 mm � 3 mm
Creepage distance between coil and contacts � 10 mm � 4 mm � 3.2 mm � 4.2 mm
Overvoltage category III III II III
Pollution degree 3 3 2 3
Pluggable interface relays
Technical data - CR-P, CR-M, CR-U
* Those ratings are based on different type tests but they are not covered by the cULus or CSA approvals.
5
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/18
Type CR-P...1 CR-P...2 CR-M...2 CR-M...3 CR-M...4 CR-U...2 CR-U...3
General data
Dimensions (W x H x D) when mounted 12.7 x 29 x 15.7 mm 21.2 x 27.5 x 35.6 mm 35 x 35 x 54.4 mm
Weight 14 g (0.031 lb) 35 g (0.077 lb) 83 g (0.18 lb)
Mounting on socket (see accessories)
Mounting position any
Degree of protection IP 67 IP 40
Electrical connection
Connection by socket
Environmental data
Ambient temperature range operation DC: -40...+85 °; AC: -40...+70 °C
DC: -40...+70 °; AC: -40...+55 °C
storage -40 ... +85 °C
Vibration resistance 10-150 Hz
n/o contact 10 g 5 g 5 g
n/c contact 10 g 5 g 5 g 5 g
Shock resistance n/o contact 30 g 20 g 10 g 10 g
n/c contact 30 g 20 g 5 g 10 g
Standards
Product standard IEC/EN 60255-23, IEC/EN 60664-1, IEC/EN 61810-1
IEC/EN 60255-23, IEC/EN 60810-1, IEC/EN 61810-7
IEC/EN 60255-1
Low Voltage Directive 2006/95/EC
Load limit curves - Maximum switching power at resistive DC load
CR-P with 1 c/o contact CR-P with 2 c/o contacts CR-U with 2 and 3 c/o contacts
CR-M with 2 c/o contacts CR-M with 3 c/o contacts CR-M with 4 c/o contacts
2C
DC
292 0
05 F
0204
DC
cur
rent
[A]
DC voltage [V]
2C
DC
292 0
10 F
0204
DC
cur
rent
[A]
DC voltage [V]
1 = resistive load, T = 0 ms
2 = inductive load, T = 40 ms
2C
DC
292 0
28 F
0204
DC voltage [V]
DC
cur
rent
[A]
2C
DC
292 0
15 F
0204
DC
cur
rent
[A]
DC voltage [V]
1 = resistive load, T = 0 ms
2 = inductive load, T = 40 ms
2C
DC
292 0
19 F
0204
DC voltage [V]
DC
cur
rent
[A]
2C
DC
292 0
23 F
0204
DC voltage [V]
DC
cur
rent
[A]
Pluggable interface relays
Technical data, load limit curves - CR-P, CR-M, CR-U
Approvals see page 5/6.
5
5/19 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Pluggable interface relays
Technical data - Sockets for CR-P and CR-M
Output circuits CR-PLS CR-PLS(x) CR-PSS CR-PLC CR-MxLS CR-MxSS CR-MxSF CR-MxLCOutput circuits 11-12/14, 21-22/24 11-12/14, 21-22/24, ...
Number of poles 2 2, 3 or 4 2 or 4
Rated voltage 250 V AC 300 V AC 250 V AC 250 V AC 300 V AC
Rated current 2 x 10 A1) 2 x 12 A1) 2 x 10 A1) 7 A 10 A
General dataDimensions without holder and module (L x W x H)
76 x 15.8 x 62 mm(2.992 x 0.622 x 2.441 in)
78.5 x 15.5 x 61 mm(3.011 x 0.610 x 2.402 in)
76 x 15.8 x 42.8 mm(2.992 x 0.622 x 1.685 in)
97.5 x 16.3 x 45.2 mm(3.839 x 0.642 x 1.780 in)
75 x 27.2 x 60.8 mm(2.952 x 1.071 x 2.394 in)
75.2 x 27.2 x 42.6 mm(2.961 x 1.071 x 1.677 in)
66.7 x 30.3 x 29 mm (2.626 x 1.193 x 1.142 in)
95 x 31 x 42.5 mm(3.74 x 1.22 x 1.67 in)
Degree of protection terminals IP 20 B (EN 60529)
Temperature range operation -40...+70 °C -40...+85 °C -40...+70 °C -40...+70 °C -25...+85 °C
storage -40...+70 °C -40...+85 °C -40...+70 °C -40...+70 °C
Connection type screw connection spring connection
screw connection fork type screw
spring connection
Maximum number of wires per connecting terminal
2 2 (one perconnection point)
2 - 2 (one perconnection point)
Wire size rigid 2 x 2.5 mm2 (2 x 14 AWG) 2 x 1.5 mm2
(2 x 16 AWG)0.2 - 1.5 mm2
(24 x 16 AWG)fine-strand 2 x 2.5 mm2 (2 x 14 AWG) 0.2-1.5 mm2
(24-16 AWG)
with wire end ferule 2 x 1.5 mm2 (2 x 16 AWG) 2 x 1.5 mm2 (2 x 16 AWG)
Stripping length - 7 mm (0.28 in) - -
Tightening torque 0.6 Nm 0.8 Nm 0.6 Nm 0.6 Nm (5.31 lb.in)
Maximum clamping force
with 0.2 mm2 - - - 10 N - - - 10 N
with 1.5 mm2 - - - 40 N - - - 40 N
with wire end ferrule - - - - > 40 N
Mounting DIN rail (IEC/EN 60715)
Material socket PA 6+GF - V2 PA 6+GF - V2
contacts CuZn33 CuZn33
contact surface 5 μ Ni 5 μ tinned 5 μ Ni 5 μ Ni 6 μ Ni 5 μ tinned
terminals 8 μ Ni 8 μ galvanized 8 μ Ni XCrNi Steel 8 μ Ni CCSC
combi screw M3 8.8 Steel, 5μ Ni - 8.8 Steel, 5μ Ni -
Isolation dataInsulation voltage > 5 kV > 3 kV > 5 kV > 3 kV > 4 kV
Isolation between coil and contacts
EN 61984 VDE 0106 / 101
EN 61984 - DIN EN 61140,VDE 0140-1
Clearance and creepage distance EN 61984 DIN EN 60664-1
EN 61984 DIN EN 60664-1
StandardsProducts standard EN 61984 EN 61984 - -
Low Voltage Directive 2006/95/EC 2006/95/EC
EMC Directive - 2004/108/EC
1) Loads >10 A ( >12 A for CR-PLSx) require jumpering of terminal 11 with 21, 12 with 22, and 14 with 24
5
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/20
Pluggable interface relays
Technical data - Sockets for CR-U
Output circuits CR-U2S CR-U3S CR-U3E CR-UxSMOutput circuits 11-12/14, 21-22/24,...
Number of poles 2 3 2 or 3
Rated voltage 250 V AC 300 V AC 250 V
Rated current 10 A
General dataDimensions without holder and module (L x W x H)
75.3 x 37.3 x 26 mm(2.965 x 1.469 x 1.024 in)
75.3 x 38.1 x 26 mm(2.965 x 1.500 x 1.024 in)
70 x 38 x 26 mm(2.756 x 1.496 x 1.024 in)
61.8 x 38.1 x 26 mm(2.756 x 1.500 x 1.024 in)
Degree of protection terminals IP 20 B (EN 60529)
Temperature range operation -40...+70 °C -40...+85 °C -40...+70 °C
storage -40...+70 °C -40...+85 °C -40...+70 °C
Wire size rigid 2 x 2.5 mm2 (2 x 14 AWG)
fine-strand 2 x 2.5 mm2 (2 x 14 AWG)
with wire end ferule 2 x 1.5 mm2 (2 x 16 AWG)
Tightening torque 0.6 Nm 0.8 Nm 0.6 Nm
Mounting DIN rail (IEC/EN 60715)
Material socket PA 6+GF - V2
contacts CuZn33
contact surface 6 μ Ni 3 μ Ni
terminals 8 μ Ni 8 μ galvanized 10 μ Ni
combi screw M3 8.8 Steel, 5μ Ni Steel, 8 μ Ni
Isolation dataInsulation voltage > 2 kV
Isolation between coil and contacts
EN 61984
Clearance and creepage distance EN 61984
StandardsProducts standard EN 61984: 2001
Low Voltage Directive 2006/95/EC
5
5/21 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Pluggable interface relays
Technical data - CR-S range
Rated control supply voltage Us
Make voltage(at 23 °C)
Maxium voltage (at 55 °C)
Break voltage Rated power Coil resistance (at 23 °C)
Tolerance of coil resistance
CR-S005VDC1R(G) 5 V DC 3.75 V DC 7.5 V DC 0.25 V DC 170 mW 147 Ω ± 10 %
CR-S012VDC1R(G) 12 V DC 9 V DC 18 V DC 0.6 V DC 170 mW 848 Ω ± 10 %
CR-S024VDC1R(G) 24 V DC 18 V DC 36 V DC 1.2 V DC 170 mW 3390 Ω ± 15 %
CR-S048VDC1R(G) 48 V DC 36 V DC 72 V DC 2.4 V DC 210 mW 10600 Ω ± 15 %
CR-S060VDC1R(G) 60 V DC 45 V DC 90 V DC 3 V DC 210 mW 16600 Ω ± 15 %
Output circuits
Output circuits 11-12/14
Kind of output 1 c/o (SPDT)
Contact material AgSnO2 / AgSnO
2/Au
Rated operational voltage Ue (IEC/EN 60947-1) 250 V AC
Minimum switching voltage 12 V DC
Maximum switching voltage 400 V AC / 125 V DC
Minimum switching current 100 mA (AgSnO2) / 10 mA (AgSnO
2/Au)
Rated free air thermal current Ith
5 A
Rated operational current (IEC/EN 60947-5-1) AC12 (resistive) 230 V 6 A
AC15 (inductive) 230 V 1.5 A
AC15 (inductive) 120 V 3 A
DC12 (resistive) 24 V 6 A
DC13 (inductive) 24 V 1 A
DC13 (inductive) 120 V 0.22 A
DC13 (inductive) 250 V 0.11 A
AC rating (UL 508; NEMA ICS-5) Utilization category (pilot duty) (Contact rating code designation)
B300
DC rating (UL 508; NEMA ICS-5) Utilization category (pilot duty) (Contact rating code designation)
R300
Maximum making (inrush) current 15 A, 240 V AC
Minimum switching power 100 mA/12 V (AgSnO2) / 50 mW (AgSnO
2/Au)
Maximum switching (breaking) power AC1 (resistive) 1500 VA, 250 V AC
Contact resistance 100 m (at 1 A/ 6 V DC)
Maximum operating frequency rated load AC1 360 switching cycles/h
without load 18000 switching cycles/h
Mechanical lifetime 1 x 107 switching cycles
Electrical lifetime AC1 (resistive) (n/c) 3 x 104 switching cycles (at +85 °C)(n/o) 1 x 104 switching cycles (at +85 °C)
Response time 8 ms
Release time 4 ms
Isolation dataRated insulation voltage 250 V AC
Rated impulse withstand voltage Uimp
between coil and contacts 4000 V AC 1 min
between open contacts 1000 V AC 1 min
Clearance between coil and contacts 5.5 mm (0.217 in)
Creepage distance between coil and contacts 8 mm (0.315 in)
Overvoltage category III
Pollution degree 2
General dataDimensions (W x H x D) 28 x 5 x 15 mm (1.102 x 0.196 x 0.590 in)
Weight 5 g (0.011 lb)
Mounting on socket
Mounting position any
Degree of protection RT II and RT III
Electrical connectionConnection by socket
Environmental dataAmbient temperature range operation -40...+85 °C
storage 0...+40 °C
Vibration resistance (10-150 Hz) n/o contact 10 Hz to 55 Hz 1mm DA
n/c contact 10 Hz to 55 Hz 1mm DA
Shock resistance n/o contact Functional 49 m/s² / Destructive 980 m/s²
n/c contact Functional 49 m/s² / Destructive 980 m/s²
StandardsProduct standard IEC 61810-1
Low Voltage Directive 2006/95/EC
5
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/22
Pluggable interface relays
Technical data - CR-S range sockets
Input circuits CR-S 6-24 V CR-S 12-24 V CR-S 48-60 V CR-S 110-125 V CR-S 220-240 V
Rated control supply voltage Us
6-24 V DC 2-24 V AC/DC 48-60 V AC/DC 110-125 V AC/DC 220-240 V AC/DC
Rated control supply voltage Us tolerance (0.8-1.2) U
n(0.8-1.1) U
n
Typical current 11-29 mA 11-16 mA 3.6-4.5 mA 3.6 mA 3.6 mA
Response time 8 ms
Release time 4 ms
Status device green LED
Protective circuit yes
Output circuits
Output circuits 11-12/14
Number of poles 1
Rated voltage 250 V AC
Rated current 6 A
General data for CR-S with screw connection terminal
Dimensions without holder (L x W x H) 88.3 x 6.3 x 70.9 mm (3.476 x 0.248 x 2.789 in)
Degree of protection (EN 60529) Degree of protection (EN 60529) IP20 (terminals)
Temperature range operation -40...+70 °C -40...+55 °Cstorage 0...+40 °C
Connection type Screw
Maximum nuber of wires per connection terminal 2
Wire size rigid 1 x 2.5 mm² (1 x 14 AWG) ; 2 x 1.5 mm² (2 x 16 AWG)
fine-strand 1 x 2.5 mm² (1 x 14 AWG); 2 x 1.5 mm² (2 x 16 AWG)
with wire end ferule 1 x 2.5 mm² (1 x 14 AWG); 2 x 1.0 mm² (2 x 18 AWG)
Tightening torque 0.5 Nm (4.426 lb.in)
Stripping length 7 mm (0.276 in)
Mounting (IEC/EN 60715) DIN railMaterial socket PA6 +GF-V2
contacts CuZn36
contact surface 3 μ Ni/Sn
terminals CuZn40, 3 μ Ni
combi screw M3 Fe
General data for CR-S with spring connection terminalDimensions without holder (L x W x H) 88.3 x 6.3 x 70.9 mm (3.476 x 0.248 x 2.789 in)
Degree of protection (EN 60529) Degree of protection (EN 60529) IP20 (terminals)
Temperature range operation -40...+70 °C -40...+55 °C
storage 0...+40 °C
Connection type Spring
Maximum nuber of wires per connection terminal 1
Wire size 2.5 mm² (14 AWG) rigid, fine-strand and with wire end ferule
Stripping length 7 mm (0.276 in)
Mounting (IEC/EN 60715) DIN rail
Material socket PA6 +GF-V2
contacts CuZn36
contact surface 3 μ Ni/Sn
spring terminals SUS301
Isolation dataIsolation between coil and contacts 5000 V AC
Resistance to shock coil to contact 1000 M
Clearance and creepage distance IEC/EN 61984
StandardsProduct stancard IEC/EN 61984: 2001
Low Voltage Directive 2006/95/EC
Load limit curves - Max. DC load breaking capacity Endurance curve
DC
curr
ent
(A)
DC voltage (V)
100.1
0.2
0.5
1
2
5
10
20 50 100 200
2C
DC
29
2 0
12
F0
21
4
Contact current (A)
Op
era
tio
ns (*1
00
0 o
ps)
0
5
10
50
100
1 2 3 4 5 6 7 8
2C
DC
29
2 0
13
F0
21
4
5
5/23 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Load limit curves - Electrical lifetime at resistive AC load
CR-P with 1 c/o contact CR-P with 2 c/o contacts CR-U with 2 and 3 c/o contacts
CR-M with 2 c/o contacts CR-M with 3 c/o contacts CR-M with 4 c/o contacts
2C
DC
29
2 0
03
F0
20
4
Sw
itchi
ng c
ycle
s
Switching power [kVA]
2C
DC
29
2 0
09
F0
20
4
Sw
itchi
ng c
ycle
s
Switching power [kVA]
2C
DC
29
2 0
27
F0
20
4
Sw
itchi
ng c
ycle
s
Switching power [kVA]
2C
DC
292 0
13 F
0204
Sw
itchi
ng c
ycle
s
Switching power [kVA]
2C
DC
292 0
18 F
0204
Sw
itchi
ng c
ycle
s
Switching power [kVA]
2C
DC
292 0
22 F
0204
Sw
itchi
ng c
ycle
s
Switching power [kVA]
Reduction factor F at inductive AC load
2C
DC
292 0
04 F
0204
Red
uctio
n fa
ctor
Power factor
2C
DC
292 0
14 F
0204
Red
uctio
n fa
ctor
Power factor Power factor
Red
uctio
n fa
ctor
2C
DC
292 0
29 F
0204
CR-P CR-M CR-U
Pluggable interface relays
Load limit curves
5
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/24
Connection diagrams
Dimensional drawings Dimensions in mm and inches
CR-M with 2 c/o contacts
CR-P with 1 c/o contact CR-M with 2 c/o contacts CR-M with 3 c/o contacts CR-U with 2 c/o contacts
CR-P with 2 c/o contacts CR-M with 4 c/o contacts CR-S CR-U with 3 c/o contacts
CR-U with 2 c/o contacts
CR-P
CR-S
CR-M with 3 c/o contacts
CR-M with 4 c/o contacts
CR-U with 3 c/o contacts
2C
DC
29
2 0
01
F0
00
42
CD
C 2
92
00
8 F
00
04
2C
DC
29
2 0
02
F0
00
42
CD
C 2
92
05
2 F
00
13
1 0.039
0.5 0.0200.9 0.035
0.5
0.02
0
3.78 0.1495.04 0.198
5 0.19716.38 0.645
28 1.102
15 0
.591
3.5
0.13
8
2C
DC
29
2 0
11
F0
00
4
2C
DC
29
2 0
16
F0
00
4
2C
DC
29
2 0
20
F0
00
4
2C
DC
29
2 0
01
F0
01
4
2C
DC
29
2 0
01
F0
01
52
CD
C 2
92
00
2 F
00
15
2C
DC
29
2 0
03
F0
01
5
2C
DC
29
2 0
24
F0
00
42
CD
C 2
92
03
0 F
00
04
2C
DC
29
2 0
25
F0
00
42
CD
C 2
92
02
6 F
00
04
Pluggable interface relays
Connection diagrams
5
5/25 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
20.3
2
5.08
5.08
15.5
7.62
29.4
3.2
78.5
24
50
62
61
42.5
Pluggable interface relays
Dimensional drawings
Dimensions in mm and inches
Relay
Jumper
CR-PLS - screw connection
CR-PLSx - screw connection
CR-PSS - screw connection
2C
DC
29
2 0
33
F0
00
4
2C
DC
29
2 0
53
F0
01
3
2C
DC
29
2 0
54
F0
01
3
2C
DC
29
2 0
03
F0
01
4
2C
DC
29
2 0
02
F0
01
4
CR-PLC - spring connection
CR-PJ
62
51,2
2915,87,5
76
20
10
Marker
Relay
Holder
Pluggable function module
42.8
15,8
24
76
10
20
Marker
Holder
Relay
Pluggablefunction module
2C
DC
29
2 0
06
F0
21
1
2C
DC
29
2 0
07
F0
21
1
7,62
97,5
25,9
20,3
2
5,08
5,08
24,4
16,3
33,8
43,5
34,4
1,51
0
10
R1
2±0,2
15,5±0,2
9x15 (=139,5)
141,5+1
6±
0,2
2C
DC
29
2 0
10
F0
01
1
2C
DC
29
2 0
12
F0
01
1
Pluggable function
module
Holder
76.6 3.016
73.2 2.882
3.5 0.138
35.4
1.3
94
94.7
3.7
28
6.2 0.244
6.3 0.248
123.2 4.850
6.7
0.26
4
70.9 2.791
6.3 0.272
44.2
1.7
4
52 2
.047
69.4
2.7
32
88.3
3.4
76
28 1
.102
35.4
1.3
94
55.4 2.181
35.8 1.409
92.7 3.650
35.7 1.406
20.6
0.8
11
40.2
1.5
83
59.8
2.3
54
71.1
2.7
99
Spring socket for CR-S range interface relays
Jumper bar CR-S
Screw socket for CR-S range interface relays Separator for CR-S
5
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/26
Pluggable interface relays
Dimensional drawings
Dimensions in mm and inches
2C
DC
29
2 0
81
F0
00
4
CR-U2S - CR-U3S
CR-M2SS - CR-M3SS - CR-M4SS - screw connection
CR-M2LS - CR-M3LS - CR-M4LS - screw connection
CR-U3E
CR-U2SM
2C
DC
29
2 0
02
F0
00
5
CR-U3SM
31
27 26
79,5
42,5
33,2
24
12,4
12,4
15
95
5,5
2C
DC
292 0
06 F
0005
30,3
66,7
35,4
29 max
19
CR-M2LC , CR-M4LC - spring connection
CR-MxSF - screw connection
CR-MJ
9 - M3
12 - M3
37,3 38,1
29,8 29,8
4
75,3
75,3
35,4
CR-U2S CR-U3S
27,2
27,2 27,2
75
,2
35
,4
24
42,6
Marker
Relay
Holder
Pluggable function module
2C
DC
29
2 0
08
F0
01
1
29,1
2442,6
75
60,827,2
27,2 27,2
75 35,4
Marker
Relay
Holder
Pluggablefunction module
CR-M2LS CR-M3LS CR-M4LS
2C
DC
29
2 0
04
F0
21
1
2C
DC
29
2 0
05
F0
01
1
2C
DC
29
2 0
03
F0
21
1
11 - M3
27,8
38,126
61,8
4
35,4
27,8
38,1
CR-U2SM CR-U3SM
8 - M3
61,8
2C
DC
29
2 0
09
F0
01
1
246.
8
1
9,5
10
R1
9 x
27.2
(=24
4,8)
27.2
±0.
2
6±0,22±0,
2
2C
DC
29
2 0
11
F0
01
1
5
5/27 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Interface relays and optocouplers R600 range
Product group picture
5
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/28
Interface relays and optocouplers R600 range
Table of contents
Interface relays and optocouplers R600 range
Benefits and advantages 5/29
Type designators 5/30
Interface relays R600 range ............................................................. 5/31
Benefits and advantages 5/31
Selection 5/33
Ordering details 5/35
Connection diagrams 5/37
Technical data 5/38
General technical data 5/43
Dimensional drawings, Load limit curves 5/44
Optocouplers R600 range ............................................................... 5/45
Selection 5/45
Ordering details 5/47
Connection diagrams 5/48
Technical data 5/49
5
5/29 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Interface relays and optocouplers R600 range
Benefits and advantages
In today’s automation systems, PLCs are the core of industry. They link sensors and actuators to the process, which are con-
nected to the PLC via conventional wires.
However these PLCs are not completely isolated from the industrial environment, hence over voltage picks and transient cur-
rents can affect their operating functions. And additionally, their application field is often limited to 24 VDC / 100 mA.
So, with the aim to adapt application voltage and/or current and provide as well the right electrical isolation to the PLC, it is
recommended to install per I/O the right interface providing both voltage-current level adaptation and isolation protection.
This interfacing is possible thanks to ABB’s relays and optocouplers ranges, which offer wide adaptation in both voltage (from 5
to 400 V) and current (from 10-7 to 16 A) as well as high isolation between input and output from 2 to 4 KV.
R600 series
Standard range in screw clamp or spring clamp versions
– Spacing : 6 mm or 12 mm
– Wire size : 2.5 mm² (4 mm² solid wire)
– Contact type : 1 NO, 1 NC, 1 SPDT, 1 DPDT from
1 mA to 8 A / 250 V
2CD
C 2
91 0
24 F
0013
5
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/30
Interface relays and optocouplers R600 range
Type designators
Description of contact types
0 1 Normally Closed 1 NC
1 1 Normally Open 1 NO
2 1 Change Over or Single Pole Double Through
FeaturesNone Input voltage DC
A Input voltage AC/DC
R RC circuit protection :
- Input protection against leakage current
- Increases relay contacts life
SERIES CODE NB OF RELAYS CONTACT TYPE NB OF CONTACTS PER RELAY
PARTICULARITIES
R600 screw type R / B � � � �
R600 spring type R / B / R � � � �
1 0 1 2 1 2 None / A / R
5
5/31 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Interface relays R600 range
Benefits and advantages
Characteristics – Standard range available with screw or spring-type terminals
– 8 different rated control supply voltages:
DC versions: 5 V, 12 V, 24 V
AC/DC versions: 24 V, 48-60 V, 115 V, 230 V, 60-230 V
– Output: 1 n/c contact, 1 n/o contact, 1 c/o (SPDT) contact,
2 c/o (SPDT) contacts
– Devices with output contacts protected by built in RC cir-
cuit, which result in increased contact life
– Devices with leakage current protection on the input side
– Available with visible or covered switch on the front of the
unit, for the configuration of manual or automatic actuation
– With connection for jumper bar, except 2 c/o devices and
some discontinued devices
– Width: 6 mm (0.236 in) or 12 mm (0.472 in)
– LED for the indication of the operational state
– Accessories: Jumper bars, separator end section
– Approvals / Marks
H R P (pending) / a
Excellent adaption and conversion of digital signals
AC 110 V DC 24 V DC 24 V AC 110 V AC 380 V
AC 230V AC 230 V
Pushbutton R 600 Relay or R 600 Relay or Motor
Position Optocoupler PLC Optocoupler contactor Motor
switch
Sensor
1 Input - Control supply voltage
2 Jumper bar connection
3 Indication of operational states (green LED)
4 Output
1
2
3
4
5
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/32
Interface relays R600 range
Benefits and advantages
Increased contact lifeThe contacts of some devices are prote-
ced by built in RC-circuits which result
in increased contact life.
Space safingWith a width of only 6 mm or 12 mm the
compact design safes space in each
cabinet.
12
mm
sp
acin
g
6 m
m s
pacin
g
Variety of connectionsR600 relays and optocouplers
are available with both screw
terminals or spring terminals.
Functioning statusFunctioning display through a
green LED.
Only one part number AC/DC
Measurement & TestHoles for holding DIA. 2 mm test
plugs to simplify any measure-
ment or test.
0.2 to 2.5 mm²
0.22 to 4 mm²
Interface relays are electromechanic and electronic input and output modules for electrical isolation, levelling, noise suppression or signal
amplification between control unit and process.
Boxed interface relays are used for electrical isolation, amplification and signal matching between the electronic controlling, e.g. PLC
(programmable logic controller), PC or field bus systems and the sensor / actuator level. The compact design and different connection
terminal possibilities optimize your panel installation.
5
5/33 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Interface relays R600 range
SelectionO
rder
nu
mb
er
1S
NA
64
50
34
R2
30
0
1S
NA
64
50
36
R25
00
1S
NA
64
55
34
R25
00
1S
NA
64
55
36
R270
0
1S
NA
64
5073
R0
00
0
1S
NA
64
50
35
R24
00
1S
NA
64
5075
R0
00
0
1S
NA
64
5575
R0
00
0
1S
NA
64
55
35
R2
60
0
1S
NA
64
5573
R0
00
0
1S
NA
64
5019
R0
40
0
1S
NA
64
551
9R
06
00
1S
NA
64
5014
R270
0
1S
NA
64
5018
R0
30
0
1S
NA
64
551
4R
210
0
1S
NA
64
50
01R
03
00
1S
NA
64
50
05
R070
0
1S
NA
64
55
01R
05
00
1S
NA
64
55
05
R010
0
1S
NA
64
5012
R25
00
1S
NA
64
551
2R
270
0
1S
NA
64
5071R
00
00
1S
NA
64
5571R
00
00
1S
NA
64
5072
R0
00
0
1S
NA
64
5572
R0
00
0
1S
NA
64
50
02
R0
40
0
1S
NA
64
50
06
R0
00
0
1S
NA
64
55
02
R0
60
0
1S
NA
64
55
06
R0
20
0
1S
NA
64
50
40
R15
00
1S
NA
64
55
40
R17
00
Typ
e
RB
121-5
VD
C
RB
121-5
VD
C
RB
R 1
21-5
VD
C
RB
R 1
21-5
VD
C
RB
121-1
2V
DC
RB
121-1
2V
DC
RB
121-A
U-1
2V
DC
RB
R12
1-A
U-1
2V
DC
RB
R12
1-1
2V
DC
RB
R12
1-1
2V
DC
RB
101A
R-2
4V
AC
/DC
RB
R 1
01A
R-2
4V
AC
/DC
RB
111
A-2
4V
AC
/DC
RB
111
AR
-24V
AC
/DC
RB
R 1
11A
-24V
AC
/DC
RB
121A
-24V
AC
/DC
RB
121A
-24V
AC
/DC
RB
R 1
21A
-24V
AC
/DC
RB
R 1
21A
-24V
AC
/DC
RB
12
2A
-24V
AC
/DC
RB
R 1
22
A-2
4V
AC
/DC
RB
121-2
4V
DC
RB
R12
1-2
4V
DC
RB
121-A
U-2
4V
DC
1S
NA
64
5572
R0
00
0
RB
121A
-48
-60
VA
C/D
C
RB
121A
-48
-60
VA
C/D
C
RB
R 1
21A
-48
-60
VA
C/D
C
RB
R 1
21A
-48
-60
VA
C/D
C
RB
12
2A
-48
-60
VA
C/D
C
RB
R 1
22
A-4
8-6
0V
AC
/DC
Input voltage
5 V DC � � � �
12 V DC � � � � � �
24 V DC � � � � � � � � � � � � � � �
48-60 V DC � � � � � �
115 V DC
230 V DC
60-230 V DC
24 V AC � � � � � � � � � � �
48-60 V AC � � � � � �
115 V AC
230 V AC
60-230 V AC
Output rating
10 mA - 6 A � � � � � � � � � � � � � � � �
1 mA - 6 A � � � � � � � � � � �
1 mA - 8 A � � � �
Output contacts
c/o 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 1 1 1 1 1 1 1 1 2 2
n/o 1 1 1
n/c 1 1
Terminal type
Screw � � � � � � � � � � � � � � � �
Spring � � � � � � � � � � � � � � �
5
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/34
Interface relays R600 range
Selection
1S
NA
64
50
03
R0
50
0
1S
NA
64
50
07R
010
0
1S
NA
64
50
46
R070
0
1S
NA
64
55
03
R070
0
1S
NA
64
55
07R
03
00
1S
NA
64
55
46
R010
0
1S
NA
64
50
41R
02
00
1S
NA
64
55
41R
04
00
1S
NA
64
5016
R210
0
1S
NA
64
5017
R2
20
0
1S
NA
64
50
04
R0
40
0
1S
NA
64
50
08
R12
00
1S
NA
64
5011
R24
00
1S
NA
64
55
04
R0
00
0
1S
NA
64
55
08
R14
00
1S
NA
64
551
1R
26
00
1S
NA
64
5013
R2
60
0
1S
NA
64
551
3R
20
00
1S
NA
64
50
20
R010
0
1S
NA
64
552
0R
03
00
RB
121A
-115
VA
C/D
C
RB
121A
-115
VA
C/D
C
RB
121A
R-1
15
VA
C/D
C
RB
R 1
21A
-115
VA
C/D
C
RB
R 1
21A
-115
VA
C/D
C
RB
R 1
21A
R-1
15
VA
C/D
C
RB
12
2A
-115
VA
C/D
C
RB
R 1
22
A-1
15
VA
C/D
C
RB
111
A-1
15
VA
C/D
C
RB
111
A-2
30
VA
C/D
C
RB
121A
-23
0V
AC
/DC
RB
121A
-23
0V
AC
/DC
RB
121A
R-2
30
VA
C/D
C
RB
R 1
21A
-23
0V
AC
/DC
RB
R 1
21A
-23
0V
AC
/DC
RB
R 1
21A
R-2
30
VA
C/D
C
RB
12
2A
-23
0V
AC
/DC
RB
R 1
22
A-2
30
VA
C/D
C
RB
121A
60
-23
0V
UC
RB
R 1
21A
60
-23
0V
UC
� � � � � � � � �
� � � � � � � � �� �
� � � � � � � � �
� � � � � � � � �� �
� � � � � � � � � � � �
� � � �
� � � �
1 1 1 1 1 1 2 2 1 1 1 1 1 1 2 2 1 1
1 1
� � � � � � � � � � �
� � � � � � � � �
5
5/35 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Interface relays R600 range
Ordering details
Ordering details - 1 n/c contact: 250 V, 10 mA - 6 A (high level), width 12 mm Rated control supply voltage
Particularities and connection type
Type Order code Price Pkg qty
Weight(1 pce)kg (lb)
24 V AC/DCRC circuit parallel to contact on output side
RB101AR-24VAC/DC 1SNA645019R04005
0.04 (0.088)RBR101AR-24VAC/DC 1SNA645519R0600
Ordering details - 1 n/o contact: 250 V, 10 mA - 6 A (high level), width 12 mm Rated control supply voltage
Particularities and connection type
Type Order code Price Pkg qty
Weight(1 pce)kg (lb)
24 V AC/DCRC circuit parallel to contact on output side
RB111AR-24VAC/DC 1SNA645018R03005
0.04 (0.088)RBR111AR-24VAC/DC 1SNA645518R0500
Ordering details - 1 c/o (SPDT) contact: 250 V, 1 mA - 6 A (low level), width 6 mm Rated control supply voltage
Particularities and connection type
Type Order code Price Pkg qty
Weight(1 pce)kg (lb)
5 V DC A1-A2 polarized RB121-5VDC 1SNA645036R2500
100.02 (0.044)
12 V DC RB121-AU-12VDC 1SNA645075R0000
24 V DC RB121-AU-24VDC 1SNA645072R0000
24 V AC/DC RB121A-24VAC/DC 1SNA645005R0700
48-60 V AC/DC RB121A-48-60VAC/DC 1SNA645006R0000
115 V AC/DC RB121A-115VAC/DC 1SNA645007R0100
230 V AC/DC RB121A-230VAC/DC 1SNA645008R1200
5 V DC A1-A2 polarized RBR121-5VDC 1SNA645536R2700
12 V DC RBR121-AU-12VDC 1SNA645575R0000
24 V DC RBR121-AU-24VDC 1SNA645572R0000
24 V AC/DC RBR121A-24VAC/DC 1SNA645505R0100
48-60 V AC/DC RBR121A-48-60VUC 1SNA645506R0200
115 V AC/DC RBR121A-115VAC/DC 1SNA645507R0300
230 V AC/DC RBR121A-230VAC/DC 1SNA645508R1400
Ordering details - 1 n/o contact: 250 V, 10 mA - 6 A (high level) width 6 mm Rated control supply voltage
Particularities and connection type
Type Order code Price Pkg qty
Weight(1 pce)kg (lb)
24 V AC/DC RB111A-24VAC/DC 1SNA645014R2700
100.02 (0.044)
115 V AC/DC RB111A-115VAC/DC 1SNA645016R2100
230 V AC/DC RB111A-230VAC/DC 1SNA645017R2200
24 V AC/DC RBR111A-24VAC/DC 1SNA645514R2100
R600 - 6 mm
screw terminals
spring terminals
2C
DC
29
1 0
24
S0
01
3
5
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/36
Ordering details - 1 c/o (SPDT) contact: 250 V, 10 mA - 6 A (high level), width 6 mm Rated control supply voltage
Particularities and connection type
Type Order code Price Pkg qty
Weight(1 pce)kg (lb)
5 V DC A1-A2 polarized RB121-5VDC 1SNA645034R2300
100.02 (0.044)
12 V DC A1-A2 polarized RB121-12VDC 1SNA645035R2400
12 V DC RB121-12VDC 1SNA645073R0000
24 V DC RB121-24VDC 1SNA645071R0000
24 V AC/DC RB121A-24VAC/DC 1SNA645001R0300
48-60 V AC/DC RB121A-48-60VAC/DC 1SNA645002R0400
115 V AC/DC RB121A-115VAC/DC 1SNA645003R0500
230 V AC/DC RB121A-230VAC/DC 1SNA645004R0400
5 V DC A1-A2 polarized RBR121-5VDC 1SNA645534R2500
12 V DC A1-A2 polarized RBR121-12VDC 1SNA645535R2600
12 V DC RBR121-12VDC 1SNA645573R0000
24 V DC RBR121-24VDC 1SNA645571R0000
24 V AC/DC RBR121A-24VAC/DC 1SNA645501R0500
48-60 V AC/DC RBR121A-48-60VUC 1SNA645502R0600
115 V AC/DC RBR121A-115VAC/DC 1SNA645503R0700
230 V AC/DC RBR121A-230VAC/DC 1SNA645504R0000
Ordering details - 1 c/o (SPDT) contact: 250 V, 10 mA - 6 A (high level), width 12 mm Rated control supply voltage
Particularities and connection type
Type Order code Price Pkg qty
Weight(1 pce)kg (lb)
60-230 V AC/DC RB121A-60-230VUC 1SNA645020R0100
0.04 (0.088)
115 V AC/DCLeakage current protection, input side
RB121AR-115VAC/DC 1SNA645046R0700
230 V AC/DC RB121AR-230VAC/DC 1SNA645011R2400
60-230 V AC/DC RBR121A-60-230VUC 1SNA645520R0300
115 V AC/DCLeakage current protection, input side
RBR121AR-115VAC/DC 1SNA645546R0100
230 V AC/DC RBR121AR-230VAC/DC 1SNA645511R2600
Ordering details - 2 c/o (SPDT) contacts: 250 V, 1 mA - 8 A (low level), width 12 mm Rated control supply voltage
Connection type Type Order code Price Pkg qty
Weight(1 pce)kg (lb)
24 V AC/DC RB122A-24VAC/DC 1SNA645012R2500
50.04 (0.088)
48-60 V AC/DC RB122A-48-60VAC/DC 1SNA645040R1500
115 V AC/DC RB122A-115VAC/DC 1SNA645041R0200
230 V AC/DC RB122A-230VAC/DC 1SNA645013R2600
24 V AC/DC RBR122A-24VAC/DC 1SNA645512R2700
48-60 V AC/DC RBR122A-48-60VUC 1SNA645540R1700
115 V AC/DC RBR122A-115VAC/DC 1SNA645541R0400
230 V AC/DC RBR122A-230VAC/DC 1SNA645513R2000
Ordering details - Accessories Description Type Order code Price Pkg
qtyWeight(1 pce)kg (lb)
24 V AC/DC BJ 612-10 1SNA290488R0100
10
0.05 (0.11)
48-60 V AC/DC BJ 612-20 1SNA206754R0000 0.01 (0.022)
230 V AC/DC SC 612 1SNA290474R0200 0.05 (0.11)
screw terminals
spring terminals
Interface relays R600 range
Ordering details
R600 - 12 mm
SC612BJ...
2C
DC
29
1 0
13
S0
01
3
5
5/37 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Interface relays R600 range
Connection diagrams
11-12 n/c contact A1-A2 Control supply voltage
13-14 n/o contact S1 Connection for jumper bar (input side)
11-12/14 1st c/o contact S2 Connection for jumper bar (output side)
21-22/24 2nd c/o contact
A1
A2
S111S2
122
CD
C 2
92
03
0 F
00
13
A1
A2
S1
14S2
13
2C
DC
29
2 0
31
F0
01
3
A1
A2
S1
14S2
13
2C
DC
29
2 0
33
F0
01
3
RB/RBR 101 AR RB/RBR 111 A - 24 V AC/DC RB/RBR 111 A - 48/60/115/230 V AC/DC
A1
A2
S1
14S2
13
2C
DC
29
2 0
35
F0
01
3
A1
A2
S1
11S2
12 14
2C
DC
29
2 0
36
F0
01
3
A1
A2
S111S2
12 14
2C
DC
29
2 0
38
F0
01
3
RB/RBR 111 AR RB/RBR 121 - 5 V DC, A1-A2 polarized - 12 V DC, A1-A2 polarized, i.e. only: 1SNA645035R2400, 1SNA645535R2600
RB/RBR 121 (AU)- 12/24 V DC, except:1SNA645035R2400, 1SNA645535R2600see connection diagram RB...121-5VDC
A1
A2
S111S2
12 14
2C
DC
29
2 0
39
F0
01
3
A1
A2
S1
11S2
12 14
2C
DC
29
2 0
40
F0
01
3
A1
A2
S111S2
12 14
2C
DC
29
2 0
42
F0
01
3
RB/RBR 121 A - 24 V AC/DC RB/RBR 121 A - 48/60/115/230 V AC/DC RB/RBR 121 AR
A1
A2
S111 21
12 14 22 24
2C
DC
29
2 0
43
F0
01
3
A1
A2
S111 21
12 14 22 24
2C
DC
29
2 0
44
F0
01
3
RB/RB 122 A - 24/48/60 V AC/DC RB/RBR 122 A - 115/230 V AC/DC
5
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/38
Interface relays R600 range
Technical data
Technical data
RB... 111A high level
Input circuitRated control supply voltage U
s24 V AC/DC 48 V AC/DC 60 V AC/DC 115 V AC/DC 230 V AC/DC
Rated control supply voltage Us
toleranceDC -15 %, +20 % -15 %, +10 %
AC -/+ 10 %
Rated frequency 50/60 Hz
Typical power consumption 0.24 W 0.34 W 0.54 W 0.46 W 0.8 W
Typical current 10 mA 7 mA 9 mA 4 mA 3.5 mA
Drop-out voltage 4.5 V 8 V 8 V 17 V 27 V
Indication of operational states green LED V: control supply voltage applied
Output circuitKind of output 13-14 relay, 1 n/o contact
Rated operational voltage Ue (IEC/EN 60947-1) 250 V AC
Minimum switching voltage 12 V
Maximum switching voltage 250 V AC
Minimum switching current 10 mA
Rated free air thermal current Ith
6 A
Rated operational current (IEC/EN 60947-5-1)
AC-12 (resistive) 230 V 6 A
AC-15 (inductive) 230 V 1.5 A
AC-15 (inductive) 120 V 3 A
DC-12 (resistive) 24 V 6 A
DC-13 (inductive) 24 V 1 A
DC-13 (inductive) 120 V 0.2 A
DC-13 (inductive) 230 V 0.1 A
AC rating (UL 508; NEMA ICS-5)
Utilization category (pilot duty) B300
DC rating (UL 508; NEMA ICS-5)
Utilization category (pilot duty) R300
Minimum switching power 0.6 W / 0.6 VA
Mechanical lifetime 1 x 107 switching cycles
Electrical lifetime at AC-15 1 x 105 switching cycles
Response time 5 ms 5 ms 5 ms 6 ms 7 ms
Release time 8 ms 8 ms 8 ms 15 ms 15 ms
Dimensions and weight RB 111 A high level RBR 111 A high levelWeight net weight 0.02 kg (0.044 lb)
Dimension product dimension 6 x 70 x 75 mm (0.236 x 2.76 x 2.95 in) 6 x 75 x 75 mm (0.236 x 2.95 x 2.95 in)
5
5/39 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Interface relays R600 range
Technical data
Technical dataRB... 111AR high level RB... 101AR high level
Input circuitRated control supply voltage U
s24 V AC/DC
Rated control supply voltage Us
toleranceDC -15 %, +20 %
AC -/+ 10 %
Rated frequency 50/60 Hz
Typical power consumption 0.24 W
Typical current 10 mA
Drop-out voltage 4.5 V
Indication of operational states green LED V: control supply voltage applied
Output circuitKind of output 11-12 - relay, 1 n/c contact
13-14 relay, 1 n/o contact -
Rated operational voltage Ue (IEC/EN 60947-1) 250 V AC
Minimum switching voltage 12 V
Maximum switching voltage 250 V AC
Minimum switching current 10 mA
Rated free air thermal current Ith
6 A
Rated operational current (IEC/EN 60947-5-1)
AC-12 (resistive) 230 V 6 A
AC-15 (inductive) 230 V 1.5 A
AC-15 (inductive) 120 V 3 A
DC-12 (resistive) 24 V 6 A
DC-13 (inductive) 24 V 1 A
DC-13 (inductive) 120 V 0.2 A
DC-13 (inductive) 230 V 0.1 A
AC rating (UL 508; NEMA ICS-5)
Utilization category (pilot duty) B300
DC rating (UL 508; NEMA ICS-5)
Utilization category (pilot duty) R300
Minimum switching power 0.6 W / 0.6 VA
Mechanical lifetime 1 x 107 switching cycles
Electrical lifetime at AC-15 1 x 105 switching cycles
Response time 5 ms
Release time 8 ms
Dimensions and weight RB 111AR / RB 101AR high level RBR 111A / RBR 111AR high levelWeight net weight 0.03 kg (0.066 lb)
Dimension product dimension 12 x 70 x 75 mm (0.472 x 2.76 x 2.95 in) 12 x 75 x 75 mm (0.472 x 2.95 x 2.95 in)
5
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/40
Interface relays R600 range
Technical data
Technical dataRB... 121 / RB... 121A high level
Input circuitRated control supply voltage U
s5 V DC 12 V DC 24 V AC/DC 48 V AC/DC 60 V AC/DC 115 V AC/DC 230 V AC/DC
Rated control supply voltage Us
toleranceDC -15 %, +20 % -15 %, +10 %
AC - -/+ 10 %
Rated frequency - 50/60 Hz
Typical power consumption 0.2 W 0.2 W 0.24 W 0.33 W 0.54 W 0.46 W 0.8 W
Typical current 40 mA 16 mA 10 mA 7 mA 9 mA 4 mA 3.5 mA
Drop-out voltage 1.2 V 2.2 V 4.5 V 8 V 8 V 17 V 27 V
Indication of operational states green LED V: control supply voltage applied
Output circuitKind of output 11-12/14 relay, 1 c/o (SPDT) contact
Rated operational voltage Ue (IEC/EN 60947-1) 250 V AC
Minimum switching voltage 12 V
Maximum switching voltage 250 V AC
Minimum switching current 10 mA
Rated free air thermal current Ith
6 A
Rated operational current (IEC/EN 60947-5-1)
AC-12 (resistive) 230 V 6 A
AC-15 (inductive) 230 V 1.5 A
AC-15 (inductive) 120 V 3 A
DC-12 (resistive) 24 V 6 A
DC-13 (inductive) 24 V 1 A
DC-13 (inductive) 120 V 0.2 A
DC-13 (inductive) 230 V 0.1 A
AC rating (UL 508; NEMA ICS-5)
Utilization category (pilot duty) B300
DC rating (UL 508; NEMA ICS-5)
Utilization category (pilot duty) R300
Minimum switching power 0.6 W / 0.6 VA
Mechanical lifetime 1 x 107 switching cycles
Electrical lifetime at AC-15 1 x 105 switching cycles
Response time 5 ms 5 ms 5 ms 5 ms 5 ms 6 ms 7 ms
Release time 8 ms 8 ms 8 ms 8 ms 8 ms 15 ms 16 ms
Dimensions and weight RB 121 / RB 121A high level RBR 121 / RBR 121 A high levelWeight net weight 0.02 kg (0.044 lb)
Dimension product dimension 6 x 70 x 75 mm (0.236 x 2.76 x 2.95 in) 6 x 75 x 75 mm (0.236 x 2.95 x 2.95 in)
5
5/41 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Interface relays R600 range
Technical data
Technical dataRB... 121 / RB... 121A low level
Input circuitRated control supply voltage U
s5 V DC 12 V DC 24 V AC/DC 48 V AC/DC 60 V AC/DC 115 V AC/DC 230 V AC/DC
Rated control supply voltage Us
toleranceDC -15 %, +20 % -15 %, +10 %
AC - -/+ 10 %
Rated frequency - 50/60 Hz
Typical power consumption 0.2 W 0.2 W 0.24 W 0.33 W 0.54 W 0.46 W 0.8 W
Typical current 40 mA 16 mA 10 mA 7 mA 9 mA 4 mA 3.5 mA
Drop-out voltage 1.2 V 2.2 V 4.5 V 8 V 8 V 17 V 27 V
Indication of operational states green LED V: control supply voltage applied
Output circuitKind of output 11-12/14 relay, 1 c/o (SPDT) contact
Rated operational voltage Ue (IEC/EN 60947-1) 250 V AC
Minimum switching voltage 5 V
Maximum switching voltage 250 V AC
Minimum switching current 1 mA
Rated free air thermal current Ith
6 A
Rated operational current (IEC/EN 60947-5-1)
AC-12 (resistive) 230 V 6 A
AC-15 (inductive) 230 V 1.5 A
AC-15 (inductive) 120 V 3 A
DC-12 (resistive) 24 V 6 A
DC-13 (inductive) 24 V 1 A
DC-13 (inductive) 120 V 0.2 A
DC-13 (inductive) 230 V 0.1 A
AC rating (UL 508; NEMA ICS-5)
Utilization category (pilot duty) B300
DC rating (UL 508; NEMA ICS-5)
Utilization category (pilot duty) R300
Minimum switching power 0.05 W / 0.05 VA
Mechanical lifetime 1 x 107 switching cycles
Electrical lifetime at AC-15 1 x 105 switching cycles
Response time 5 ms 5 ms 5 ms 5 ms 5 ms 6 ms 7 ms
Release time 8 ms 8 ms 8 ms 8 ms 8 ms 15 ms 16 ms
Dimensions and weight RB 121 / RB 121A low level RBR 121 / RBR 121 A low levelWeight net weight 0.02 kg (0.044 lb)
Dimension product dimension 6 x 70 x 75 mm (0.236 x 2.76 x 2.95 in) 6 x 75 x 75 mm (0.236 x 2.95 x 2.95 in)
5
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/42
Interface relays R600 range
Technical data
Technical dataRB... 121AR high level
Input circuitRated control supply voltage U
s115 V AC/DC 230 V AC/DC
Rated control supply voltage Us
toleranceDC -20%, +15% -10%, +15%
AC -/+ 10 %
Rated frequency 50/60 Hz
Typical power consumption 2 W 2.8 W
Typical current 18 mA 12 mA
Drop-out voltage 17 V 27 V
Indication of operational states green LED V: control supply voltage applied
Output circuitKind of output 11-12/14 relay, 1 c/o (SPDT) contact
Rated operational voltage Ue (IEC/EN 60947-1) 250 V AC
Minimum switching voltage 12 V
Maximum switching voltage 250 V AC
Minimum switching current 10 mA
Rated free air thermal current Ith
6 A
Rated operational current (IEC/EN 60947-5-1)
AC-12 (resistive) 230 V 6 A
AC-15 (inductive) 230 V 1.5 A
AC-15 (inductive) 120 V 3 A
DC-12 (resistive) 24 V 6 A
DC-13 (inductive) 24 V 1 A
DC-13 (inductive) 120 V 0.2 A
DC-13 (inductive) 230 V 0.1 A
AC rating (UL 508; NEMA ICS-5)
Utilization category (pilot duty) B300
DC rating (UL 508; NEMA ICS-5)
Utilization category (pilot duty) R300
Minimum switching power 0.6 W / 0.6 VA
Mechanical lifetime 1 x 107 switching cycles
Electrical lifetime at AC-15 1 x 105 switching cycles
Response time 6 ms 7 ms
Release time 15 ms 16 ms
Dimensions and weight RB 121AR high level RBR 121AR high levelWeight net weight 0.03 kg (0.066 lb)
Dimension product dimension 12 x 70 x 75 mm (0.472 x 2.76 x 2.95 in) 12 x 75 x 75 mm (0.472 x 2.95 x 2.95 in)
Technical dataRB... 122A low level
Input circuitRated control supply voltage U
s24 V AC/DC 48 V AC/DC 60 V AC/DC 115 V AC/DC 230 V AC/DC
Rated control supply voltage Us
toleranceDC -15 %, +20 % -15 %, +10 %
AC -/+ 10 %
Rated frequency 50/60 Hz
Typical power consumption 0.48 W 0.62 W 0.96 W 0.58 W 1.15 W
Typical current 20 mA 13 mA 16 mA 5 mA 5 mA
Drop-out 5.4 V 8.8 V 8.8 V V 20 V 10 V
Indication of operational states green LED V: control supply voltage applied
Output circuitKind of output 11-12/14 relay, 1st c/o (SPDT) contact
21-22/24 relay, 2nd c/o (SPDT) contact
Rated operational voltage Ue (IEC/EN 60947-1) 250 V AC
Minimum switching voltage 5 V
Maximum switching voltage 250 V DC - 250 V AC
Minimum switching current 1 mA
Rated free air thermal current Ith
8 A
Rated operational current (IEC/EN 60947-5-1)
AC-12 (resistive) 230 V 8 A
DC-12 (resistive) 24 V 8 A
Minimum switching power 5 mW / 5 mVA
Mechanical lifetime 2 x 107 switching cycles
Electrical lifetime at AC-15 1 x 105 switching cycles
Response time 6 ms 10 ms 10 ms 6 ms 6 ms
Release time 10 ms 14 ms 14 ms 15 ms 15 ms
Dimensions and weight RB 122A low level RBR 122A low levelWeight net weight 0.03 kg (0.066 lb)
Dimension product dimension 12 x 70 x 75 mm (0.472 x 2.76 x 2.95 in) 12 x 75 x 75 mm (0.472 x 2.95 x 2.95 in)
5
5/43 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Technical dataRB RBR
General dataMaterial of housing UL 94 V0
Mounting DIN Rail
Degree of protection housing / terminals
IP20 NEMA1
Electrical connection Screw terminal Spring-type terminal
Wire size fine-stranded 0.22-2.5 mm² (24-14 AWG)
rigid 0.2-4 mm² (24-12 AWG) 0.2-2.5 mm² (24-14 AWG)
Stripping length 9 mm / 0.354 in
Tightening torque 0.4-0.6 Nm (3.5-5.3 lb.in)
Environmental dataAmbient temperature ranges storage -40...+80 °C
operation -20...+70 °C
Isolation dataRated insulation voltage U
i (IEC/EN 60950-1,
EN 50178)4000 V RMS
Rated impulse withstand voltage U
imp (EN 50178)
input / output 4000 V RMS (RB122A: 3800 V RMS, RB111AR: 3500 V RMS)
shock coil / output 4000 V RMS
output / output 1000 V RMS
Interface relays R600 range
General technical data
5
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/44
Interface relays R600 range
Dimensional drawings, Load limit curves
center of rail
Screw clamp module
center of rail
Spring clamp module
All interface relays of R600 range
Load limit curves
Current (Acc)
Voltage (V
cc)
Limited load in CC
DC-12 AC-12 DC-13 AC-15
24 V 6 A 6 A 1 3 A
110/120 V 0,3 A 6 A 0.2 A 3 A
220/230 V 0.2 A 6 A 0.1 A 3 A
Current [A]
Volta
ge
[V]
resistive load
Max. DC load breaking capacity
Versions with 1 n/o, 1 n/c or 1 c/o contact Versions with 2 c/o contacts
5
5/45 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Optocouplers R600 range
Selection
Ord
er n
um
ber
1S
NA
64
50
47R
00
00
1S
NA
64
55
47R
02
00
1S
NA
64
50
21R
26
00
1S
NA
64
5521R
20
00
1S
NA
64
50
49
R12
00
1S
NA
64
55
49
R14
00
1S
NA
64
50
22
R270
0
1S
NA
64
552
2R
210
0
1S
NA
64
50
50
R17
00
1S
NA
64
55
50
R11
00
1S
NA
64
50
51R
04
00
1S
NA
64
50
25
R2
20
0
1S
NA
64
50
24
R210
0
1S
NA
64
55
51R
06
00
1S
NA
64
5525
R24
00
1S
NA
64
5524
R2
30
0
1S
NA
64
50
53
R0
60
0
1S
NA
64
55
53
R0
00
0
1S
NA
64
50
54
R070
0
1S
NA
64
50
58
R13
00
1S
NA
64
55
54
R010
0
1S
NA
64
55
58
R15
00
1S
NA
64
50
26
R2
30
0
1S
NA
64
50
59
R14
00
1S
NA
64
552
6R
25
00
1S
NA
64
55
59
R16
00
1S
NA
64
50
27R
24
00
1S
NA
64
50
29
R0
60
0
1S
NA
64
5527R
26
00
1S
NA
64
552
9R
00
00
Typ
e
OB
IC 0
10
0 5
-12
VD
C
OB
RIC
010
0 5
-12
VD
C
OB
IC 0
10
0 2
4V
DC
OB
RIC
010
0 2
4V
DC
OB
IC 0
10
0 4
8-6
0V
AC
/DC
OB
RIC
010
0 4
8-6
0V
AC
/DC
OB
IC 0
10
0 1
15
-23
0V
AC
/DC
OB
RIC
010
0 1
15
-23
0V
AC
/DC
OB
OC
10
00
-5-1
2V
DC
OB
RO
C 1
00
0-5
-12
VD
C
OB
OC
10
00
-24V
DC
OB
OC
15
00
-24V
AC
/DC
OB
OC
50
00
-24V
DC
OB
RO
C 1
00
0-2
4V
DC
OB
RO
C 1
50
0-2
4V
AC
/DC
OB
RO
C 5
00
0-2
4V
DC
OB
OC
10
00
-48
-60
VA
C/D
C
OB
RO
C 1
00
0-4
8-6
0V
AC
/DC
OB
OC
10
00
-115
VA
C/D
C
OB
OC
50
00
-115
VA
C/D
C
OB
RO
C 1
00
0-1
15
VA
C/D
C
OB
RO
C 5
00
0-1
15
VA
C/D
C
OB
OC
10
00
-23
0V
AC
/DC
OB
OC
50
00
-23
0V
AC
/DC
OB
RO
C 1
00
0-2
30
VA
C/D
C
OB
RO
C 5
00
0-2
30
VA
C/D
C
OB
OA
10
00
-24V
DC
OB
OA
20
00
-24V
DC
OB
RO
A 1
00
0-2
4V
DC
OB
RO
A 2
00
0-2
4V
DC
Input voltage
5-12 V DC � � � �
24 V DC � � � � � � � � � � � �
48-60 V DC � � � �
115-230 V DC � �
115 V DC � � � �
230 V DC� � � � � �
24 V AC � �
48-60 V AC � � � �
115-230 V AC � �
115 V AC � � � �
230 V AC � � � �
Output rating
100 mA � � � � � � � �
2 A � � � � � � � � � � � � � �
5 A � � � � � �
1 A � �
Output voltage
58 V DC � � � � � � � � � � � � � � � � � � � � � � � � � �
230 V AC � �
400 V AC � �
Terminal type
Screw � � � � � � � � � � � � � � �
Spring � � � � � � � � � � � � � � �
5
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/46
Optocouplers R600 range
Selection
1S
NA
64
50
61R
06
00
1S
NA
64
55
61R
00
00
1S
NA
64
50
62
R070
0
1S
NA
64
55
62
R010
0
1S
NA
64
50
28
R0
50
0
1S
NA
64
5528
R070
0
OB
OA
10
00
-48
-60
VA
C/D
C
OB
RO
A 1
00
0-4
8-6
0V
AC
/DC
OB
OA
10
00
-115
VA
C/D
C
OB
RO
A 1
00
0-1
15
VA
C/D
C
OB
OA
10
00
-23
0V
AC
/DC
OB
RO
A 1
00
0-2
30
VA
C/D
C
� �
� �� �
� �
� �� �
� � � � � �
� � � � � �
� � �
� � �
5
5/47 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Optocouplers R600 range
Ordering details
Ordering details - R600 rangeR600 Optocoupler Type Order code Price Pkg
qtyWeight(1 pce)kg (lb)
Optocoupler module 100 mA/DC
OBIC 0100-5-12VDC 1SNA645047R0000
100.02 (0.44)
OBIC 0100-24VDC 1SNA645021R2600
OBIC 0100-48-60VAC/DC 1SNA645049R1200
OBIC 0100-115-230VAC/DC 1SNA645022R2700
Optocoupler module 100 mA/DC
OBRIC 0100-5-12VDC 1SNA645547R0200
100.02 (0.44)
OBRIC 0100-24VDC 1SNA645521R2000
OBRIC 0100-48-60VAC/DC 1SNA645549R1400
OBRIC 0100-115-230VAC/DC 1SNA645522R2100
Optocoupler module 2 A/DC
OBOC 1000-5-12VDC 1SNA645050R1700
100.02 (0.44)
OBOC 1000-24VDC 1SNA645051R0400
OBOC 1500-24VAC/DC 1SNA645025R2200
OBOC 1000-48-60VAC/DC 1SNA645053R0600
OBOC 1000-115VAC/DC 1SNA645054R0700
OBOC 1000-230VAC/DC 1SNA645026R2300
Optocoupler module 2 A/DC
OBROC 1000-5-12VDC 1SNA645550R1100
100.02 (0.44)
OBROC 1000-24VDC 1SNA645551R0600
OBROC 1500-24VAC/DC 1SNA645525R2400
OBROC 1000-48-60VAC/DC 1SNA645553R0000
OBROC 1000-115VAC/DC 1SNA645554R0100
OBROC 1000-230VAC/DC 1SNA645526R2500
Optocoupler module 5 A/DC
OBOC 5000-24VDC 1SNA645024R2100
100.02 (0.44)
OBOC 5000-115VAC/DC 1SNA645058R1300
OBOC 5000-230VAC/DC 1SNA645059R1400
Optocoupler module 5 A/DC
OBROC 5000-24VDC 1SNA645524R2300
100.02 (0.44)
OBROC 5000-115VAC/DC 1SNA645558R1500
OBROC 5000-230VAC/DC 1SNA645559R1600
Optocoupler module 1 A/AC 6 mm spacing
OBOA 1000-24VDC 1SNA645027R2400
100.03 (0.066)
OBOA 1000-48-60VAC/DC 1SNA645061R0600
OBOA 1000-115VAC/DC 1SNA645062R0700
OBOA 1000-230VAC/DC 1SNA645028R0500
Optocoupler module 2 A/AC 12 mm spacing
OBOA 2000-24VDC 1SNA645029R0600 50.03 (0.066)
Optocoupler module 1 A/AC 6 mm spacing
OBROA 1000-24VDC 1SNA645527R2600
100.03 (0.066)
OBROA 1000-48-60VAC/DC 1SNA645561R0000
OBROA 1000-115VAC/DC 1SNA645562R0100
OBROA 1000-230VAC/DC 1SNA645528R0700
Optocoupler module 2 A/AC 12 mm spacing
OBROA 2000-24VDC 1SNA645529R0000 50.03 (0.066)
Accessories Type Order code Price Pkg qty
Weight(1 pce)kg (lb)
End section
BADH V0 1SNA116900R2700 50
BADL V0 1SNA399903R0200 50
BAM2 V0 1SNA399967R0100 50
Seperator end section SC 612 1SNA290474R0200 10
Divisible shunt 10 poles BJ 612-10 1SNA290488R0100 10
Divisible shunt 20 poles BJ 612-20 1SNA206754R0000 10
Test plug DIA. 2 mm FC2 1SNA645531R2200 10
Marking method RC65 / RC610 see marking
SC612BADL BJ...
FC2D 4/12-3...
BADH
2CD
C 2
91 0
01 F
0013
screw terminals
spring terminals
5
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/48
Optocouplers R600 range
Connection diagrams
OB...IC 0100 - 5-12 V DC115-230 V AC/DC
OB...IC 010024 V DC24-48-60 V AC/DC
OB...OC 1000 - 5-12 V DC
OB...OC 1500 - 24 V AC/DC OB...OC 100024 V DC48-60-115-230 V AC/DC
OB...OC 500024 V DC24-48-60-115-230 V AC/DC
OB...OA 100024 V DC48-60-115-230 V AC/DC OB...OA 2000 - 24 V DC
5
5/49 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Optocouplers R600 range
Technical data
Optocoupler : 5 to 58 V DC output / 100 mA - 6 mm 0.236“ spacing
OB...IC 0100
Relay characteristics coil
Input voltage: +20%, -15% on DC ; 10%, -10% on AC 5 V DC - 12 V DC 24 V DC 48 V AC/DC 60 V AC/DC 115 V AC/DC 230 V AC/DC
Frequency 50 / 60 Hz
Input current AC/DC 5 mA 9 mA 4 mA 4 mA 5 mA7 mA /16 mA
11.5 mA /25 mA
Pull-in voltage at Is=100% 4 V 15 V 25 V 60 V AC / 70 V DC
Switching time C / O 10 μs / 500 μs
Operating frequency 1000 Hz 5 ms / 20 ms 5 ms / 15 ms
Permissible leakage current 20 Hz
Output 0.9 mA 1 mA 0.9 mA 1.6 mA
Output voltage 4.5 to 58 V DC
Output current min. 1 mA
Output current max. 100 mA
Output leakage current at Umax.
< 50 μA
Residual voltage at I max and U rated
typical 1 V
max 1.3 V
Frequency on inductive load
Isolation Input / Outputinput / Output
2500 V RMS
Temperaturestorage -40...+80 °C
operating -20...+70 °C 1)
Other characteristics Screw clamp Spring clamp
Body material grey UL 94 V0
Wire size
Solid wire 0.2 - 4 mm² (24-12 AWG) 0.2-2.5 mm² (24-12 AWG)
Stranded wire
0.22 - 2.5 mm² (24-12 AWG)
Rated wire size 2.5 mm² (12 AWG)
Wire stripping length 9 mm (0.354 in)
Recommended screwdriver 3.5 mm (0.137 in)
Protection IP20 NEMA1
Recommended torque 0.4-0.6 Nm (3.5-5.3 lb.in)
1) Over 55°C, blocks have to be mounted on horizontal rail with 10 mm spacing between each block. For vertical rail mounting use temperature is 15°C less decreased.
center of rail
Screw clamp module
center of rail
Spring clamp module
Dimensional drawings
5
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/50
Optocoupler : 5 to 58 V DC output / 2 A - 6 mm 0.236“ spacing
OB...OC 0100OB..OC
1500OB...OC 1000
Relay characteristics coil
Input voltage: +20%, -15% on DC ; 10%, -10% on AC
5 V DC - 12 V DC 24 V DC24 V AC/DC
48 V AC/DC
60 V AC/DC
115 V AC/DC
230 V AC/DC
Frequency 50 / 60 Hz
Input current 5 mA 9 mA 4 mA 6.3 mA 4 mA 5.1 mA 4.2 mA 4 mA
Pull-in voltage at Is=100% 4 V 15 V 15 V 27 V 50 V 80 V
Switching time C / O 15 μs / 250 μs30 μs / 400 μs
1 ms / 7 ms
5 ms / 20 ms500 μs / 10 ms
1 ms / 15 ms
Operating frequency 2000 Hz 1000 Hz 60 Hz 20 Hz
Permissible leakage current 1 mA 0.8 mA 0.9 mA 1 mA 0.3 mA
Output
Output voltage 4.5 to 58 V DC
Output current min. 1 mA
Output current max. 2 A
Output leakage current at Umax.
< 50 μA
Residual voltage at I max and U rated
typical 0.1 V
max 0.5 V
Frequency on inductive load
Isolation Input / Output input / Output 2500 V RMS
Temperaturestorage -40...+80 °C
operating -20...+70 °C 1)
Other characteristics Screw clamp Spring clamp
Body material grey UL 94 V0
Wire sizeSolid wire 0.2 - 4 mm² (24-12 AWG) 0.2-2.5 mm² (24-12 AWG)
Stranded wire 0.22 - 2.5 mm² (24-12 AWG)
Rated wire size 2.5 mm² (12 AWG)
Wire stripping length 9 mm (0.354 in)
Recommended screwdriver 3.5 mm (0.137 in)
Protection IP20 NEMA1
Recommended torque 0.4-0.6 Nm (3.5-5.3 lb.in)
1) Over 55°C, blocks have to be mounted on horizontal rail with 10 mm spacing between each block. For vertical rail mounting use temperature is 15°C less decreased.
center of rail
Screw clamp module
center of rail
Spring clamp module
Dimensional drawings
Optocouplers R600 range
Technical data
5
5/51 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
Optocouplers R600 range
Technical data
Optocoupler : 5 to 58 V DC output / 5 A - 6 mm 0.236“ spacing
OB... OC 5000
Input
Input voltage 24 V DC 115 V AC/DC 230 V AC/DC
Frequency 50 / 60 Hz 50 / 60 Hz
Input current 5.4 mA 4.2 mA 4 mA
Pull-in voltage at Is=100% 12 V 50 V 80 V
Switching time C / O 30 μs / 400 μs 500 μs / 10 ms 1ms / 15 ms
Operating frequency 1000 Hz 50 Hz 35 Hz
Permissible leakage current 0.8 mA 0.3 mA 0.3 mA
Output
Output voltage 4.5- 58 V DC
Output current min. 1 mA
Output current max. 5 A
Output leakage current at Umax.
< 50 μA
Residual voltage at I max and U rated
typical 0.1 V
max 0.5 V
Frequency on inductive load See Note 1
Isolation Input / Output input / Output 2500 V RMS
Temperature
Ambient temperature storage -40...+80 °C
operating See derating curve
Other characteristics
Body material grey UL 94 V0
Wire sizeSolid wire 0.2 - 4 mm² (24-12 AWG)
Stranded wire 0.22 - 2.5 mm² (24-12 AWG)
Rated wire size 2.5 mm² (12 AWG)
Wire stripping length 10 mm (0.394 in)
Recommended screwdriver 3.5 mm (0.137 in)
Protection IP20 NEMA1
Recommended torque 0.4-0.6 Nm (3.5-5.3 lb.in)
Dimensional drawings
center of rail
Screw clamp module
center of rail
Spring clamp module
5
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 5/52
Optocouplers R600 range
Technical data
Optocoupler : 24 to 400 V AC output / 1 A or 2 A max. - 6 mm or 12 mm spacing
OB...OA 1000OB...OA
2000
Relay characteristics coil
Input voltage: +20%, -15% on DC ; 10%, -10% on AC 24 V DC 48 V AC/DC 60 V AC/DC 115 V AC/DC 230 V AC/DC 24 V DC
Frequency 50/60 Hz
Input current 3.6 mA 4.3 mA 5.5 mA 4.15 mA 4.6 mA 3.6 mA
Pull-in voltage at Is=100% 14 V 15 V 18 V 60 V 135 V 14 V
Switching time C / O 150 μs / 1 ms 3 ms / 30 ms 2.2 ms / 18 ms 2.5 ms / 25 ms150 μs / 1 ms
Operating frequency 500 Hz 20 Hz 25 Hz 20 Hz 500 Hz
Permissible leakage current 1 mA
Output
Output voltage 24-400 V AC 10-230 V AC
Frequency 50/60 Hz
Output current min. 25 mA
Output current max. 1 A 2 A
Output leakage current at Umax.
< 0.50 mA
Residual voltage at I max and U rated
typical 1 V
max 1.6 V
Frequency on inductive load
Isolation Input / Output input / Output 2500 V RMS
Temperaturestorage -40...+80 °C
operating -20...+70 °C 1)
Other characteristics Screw clamp Spring clamp
Body material grey UL 94 V0
Wire sizeSolid wire 0.2 - 4 mm² (24-12 AWG) 0.2-2.5 mm² (24-12 AWG)
Stranded wire 0.22 - 2.5 mm² (24-12 AWG)
Rated wire size 2.5 mm² (12 AWG)
Wire stripping length 9 mm (0.354 in)
Recommended screwdriver 3.5 mm (0.137 in)
Protection IP20 NEMA1
Recommended torque 0.4-0.6 Nm (3.5-5.3 lb.in)
1) Over 55°C, blocks have to be mounted on horizontal rail with 10 mm spacing between each block. For vertical rail mounting use temperature is 15°C less decreased.
Dimensional drawings
center of rail
Screw clamp module
center of rail
Spring clamp module
6/1 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C02010
6
Logic relays
Product group picture
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 6/2
6
Logic relays
Table of contents
Logic relays
Logic relays 6/1
Product group picture 6/1
Table of contents 6/2
System overview 6/3
Approvals and marks 6/5
Ordering details - Stand alone logic relays 6/6
Ordering details - Expandable logic relays 6/7
Ordering details 6/8
Ordering details - Display systems 6/9
Technical data 6/10
Dimensional drawings 6/24
6/3 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C02010
6
Logic relays
System overview
1S
VC
11
0 0
00
F 0
55
4
S1 K1 S4
S5
K1 K2 T1
T1
T1
S6
Documentation (download from the internet)Logic relay manual: 1SVC440795M0100
Remote display manual: 1SVC440795M2100
Display system manual: 1SVC440795M1100
ConceptCL range logic relays are suitable for small and medium-
sized control tasks and are able to substitute logic wiring in
a quick and simple manner.
They can be used for applications in control as well as for
timing functions, e.g.
– in buildings, lighting systems, air-conditioning systems,
general control functions,
– in small machines and systems or
– as stand-alone control module for small applications.
Steps to the application of CL range – CL range can be used easily, rapidly and comfortably
without any time-consuming planning and programming.
– The user can discover the advantages and the benefit of
these logic relays in no time at all.
– CL range provides for the control statements according
to a simple circuit diagram.
– Setup, storage, simulation and documentation are per-
formed using the compact and user-friendly CL-SOFT
software (CL-LAS.PS002).
Software characteristics (CL-SOFT) – Display on a PC monitor according to IEC, ANSI
– Different languages to choose from
– Easy installation on all Microsoft WindowsTM operating
systems
Logic links instead of wiring
Logic relays – 8 or 12 digital inputs
– 4 or 6 digital relay outputs
– optionally with 4 or 8 transistor outputs
– 128 rungs
– 3 contacts as n/o or n/c contacts in series plus 1 coil
per rung
– optionally with 2 or 4 analog inputs (not 100-240 V AC
version)
– power flow display for checking the circuit diagram (de-
vices with display)
– expansions for local or remote level
– enclosure color RAL 7035
– DIN rail mounting
Display system – useable as compact HMI logic relay
– fully graphic, backlit display module
– 12 digital inputs
– 4 digital relay outputs
– optionally with 4 transistor outputs
– 256 rungs
– 4 contacts as n/o or n/c contacts in series plus 1 coil
per rung
– optionally with 4 analog inputs (not 100-240 V AC ver-
sion)
– networking-compatible via CL-NET
– front panel mounting
– expansion for local
Remote display – Remote display up to a distance of 5 m
– Illustration of text and status displays
– Remote adjustment via keypad
– Front panel mounting
Software – 16 timing relays 0.01-99:59 h
– 16 counting relays for up-, down counting
– 8 weekly timer, 8 annual timers
– 16 analog value comparators
– 16 freely editable display texts
– 32 markers or auxiliary relays
Technical data overview
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 6/4
6
Logic relays
System overview
Power
98a
8b
3
4
6, 8b
5
71b1a
2 2
6, 8b
5
98a
8b
Power
2C
DC
312 0
01 F
0b
08
1a Logic relay CL-LS..
1b Expandable logic relay CL-LM..
2 Power supply CP-D...
3 I/O expansion CL-LER.., CL-LET.. for logic relays CL-LM..
4 Coupler unit CL-LEC.. for remote expansion of logic relays CL-LM..
5 Memory module CL-LAS.MD003 for logic relays CL-LS.., CL-LM..
6 Connecting cable CL-LAS.TK001, CL-LAS.TK002 to connect PC
7 CL-LINK plug CL-LAS.TK011
to connect expansion to logic relays CL-LM..
8a Remote display connection module CL-LDC.S..
8b Connecting cable CL-LAD.TK007
to connect a remote displays to a logic relay
9 Display module CL-LDD..
Logic relays
Stand alone Expandable
2b
1
3
2a
5
4
2C
DC
31
2 0
37
F0
b0
7
Expansion of logic relays*
1 Logic relay CL-LM..
2 I/O expansion CL-LER.., CL-LET..
2a local expansion
2b remote expansion
3 Coupler unit CL-LEC.. for remote expansion of logic relays CL-LM..
4 CL-LINK plug CL-LAS.TK011 for expansion of logic relays CL-LM..
5 up to 30 m
* max. 1 expansion per logic relay
79
8
6
5
32
13
21
...4
4
CL-NET
10
2C
DC
312 0
25 F
0b
06
1
2
3
2C
DC
312 0
27 F
0b
06
32
1
32
1
4
...5 5
CL-NET
2C
DC
312 0
26 F
0b
06
Stand alone with I/O module
Communication via CL-NET
1 Display CL-LDD..
2 Remote display connection module CL-LDC.S..
incl. connecting cable
3 Display base module CL-LDC.L..
1 Display module CL-LDD..
2 Display base module CL-LDC.LN..
3 Display I/O module CL-LDR.., CL-LDT..
4 Termination resistor CL-LAD.TK009
5 I/O expansion CL-LER.., CL-LET..
6 Coupler unit CL-LEC.. for remote expansion
7 Memory module CL-LAD.MD004 for display base module
8 Connecting cable CL-LAD.TK002, CL-LAD.TK003,
CL-LAD.TK004
9 Connecting cable CL-LAD.TK001, CL-LAD.TK011
to connect PC
10 CL-LINK plug CL-LAS.TK011
for expansion of logic relays CL-LM..
� e.g. door of switchgear cabinet
Display system � Compact HMI logic relay
1 Display CL-LDD..
2 Display base module CL-LDC.LN.. for CL-NET
3 Display I/O module CL-LDR.., CL-LDT..
4 Connecting cable CL-LAD.TK002,
CL-LAD.TK003, CL-LAD.TK004
5 Termination resistor CL-LAD.TK009
6/5 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C02010
6
Logic relays
Approvals and marks
� existing
� pendingLogic relays Expansions Display system Accessories
Approvals CL-
LS
R
CL-
LS
T
CL-
LM
R
CL-
LM
T
CL-
LE
R
CL-
LE
T
CL-
LE
C
CL-
LD
D
CL-
LD
C
CL-
LD
R
CL-
LD
T
CL-
LA
S
CL-
LA
D
B UL � � � � � � � � � � � � 1) � 2)
F CAN/CSA C22.2 No.14 � � � � � � � � � � � � 1) � 2)
F CAN/CSA C22.2 No.213 (hazardous locations)
� � � � � � � � � � � � 1) � 2)
C GL � � � � � � 3) � 4) �
R EAC
P Lloyds Register � � � � � � 3) � 4) �
Marks
a CE � � � � � � � � � � � � �
b C-Tick
1) not for: CL-LAS-PS002, CL-LAS.TD001, CL-LAS.FD001, CL-LAS.TK002, CL-LAS.TK011 2) not for: CL-LAD.TK006, CL-LAD.TK011, CL-LAD.FD0023) not for: CL-LDC.SDC2, CL-LDC.SAC2, CL-LDC.LAC2, CL-LDC.LNAC24) not for: CL-LDR.16AC2
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 6/6
6
Logic relays
Ordering details - Stand alone logic relays
Ordering details - Logic relays stand alone
Rated opera-
tional voltage
Display
+
Keypad
Timer Input /
Output
Type Order code Price
1 pce
Weight
(1 pce)
kg (lb)
24 V AC� �
8 inputs / 4
relay outputs
CL-LSR.C12AC1 1SVR440712R0300
0.20 (0.44)
� CL-LSR.CX12AC1 1SVR440712R0200
100-240 V AC
� CL-LSR.12AC2 1SVR440713R0100
� � CL-LSR.C12AC2 1SVR440713R0300
� CL-LSR.CX12AC2 1SVR440713R0200
12 V DC� � CL-LSR.C12DC1 1SVR440710R0300
� CL-LSR.CX12DC1 1SVR440710R0200
24 V DC
� CL-LSR.12DC2 1SVR440711R0100
� � CL-LSR.C12DC2 1SVR440711R0300
� CL-LSR.CX12DC2 1SVR440711R0200
24 V DC� � 8 inputs /
4 transistor
outputs
CL-LST.C12DC2 1SVR440711R1300
� CL-LST.CX12DC2 1SVR440711R1200
Ordering details - Display modules
Rated opera-
tional voltage
Description Type Order code Price
1 pce
Weight
(1 pce)
kg (lb)
-Graphic display 132 x 64
pixelCL-LDD.XK 1SVR440839R4500 0.14 (0.30)
-Graphic display 132 x 64
pixel, with keypadCL-LDD.K 1SVR440839R4400 0.13 (0.29)
24 V DC Module to displace the dis-
play from the logic relay, incl.
connecting cable CL-LAD.
TK007, 5m, lenght adaptable
CL-LDC.SDC2 1SVR440841R0000 0.16 (0.36)
100-240 V AC CL-LDC.SAC2 1SVR440843R0000 0.16 (0.36)
CL-LSR
CL-LST
CL-LDD.K
CL-LDC.S..
2C
DC
28
1 0
34
F0
00
62
CD
C 2
81
03
3 F
00
06
2C
DC
28
1 0
28
F0
00
6
2C
DC
28
1 0
17
F0
00
7
6/7 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C02010
6
Logic relays
Ordering details - Expandable logic relays
Ordering details - Logic relays expandable
Rated
operational
voltage
Display
+
Keypad
Timer Input /
Output
Type Order code Price
1 pce
Weight
(1 pce) kg (lb)
24 V AC� �
12 inputs
/ 6 relay
outputs
CL-LMR.C18AC1 1SVR440722R0300
0.36 (0.79)
� CL-LMR.CX18AC1 1SVR440722R0200
100-240 V AC� � CL-LMR.C18AC2 1SVR440723R0300
� CL-LMR.CX18AC2 1SVR440723R0200
12 V DC� � CL-LMR.C18DC1 1SVR440720R0300
� CL-LMR.CX18DC1 1SVR440720R0200
24 V DC� � CL-LMR.C18DC2 1SVR440721R0300
� CL-LMR.CX18DC2 1SVR440721R0200
24 V DC� � 12 inputs,
8 transistor
outputs
CL-LMT.C20DC2 1SVR440721R13000.36 (0.79)
� CL-LMT.CX20DC2 1SVR440721R1200
Ordering details - Expansions
Rated opera-
tional voltage
Description Type Order code Price
1 pce
Weight
(1 pce) kg (lb)
- 2 relay outputs CL-LER.2O 1SVR440709R5000 0.07 (0.15)
100-240 V AC
12 inputs, 6 relay outputs
CL-LER.18AC2 1SVR440723R0000 0.26 (0.57)
24 V DC CL-LER.18DC2 1SVR440721R0000 0.22 (0.49)
24 V DC12 inputs, 8 transistor
outputsCL-LET.20DC2 1SVR440721R1000 0.21 (0.46)
-
Coupler unit for remote
expansion with a distance
of up to 30 m
CL-LEC.CI000 1SVR440709R0000 0.07 (0.15)
CL-LER
CL-LEC
CL-LMR
2C
DC
31
1 0
36
F0
00
62
CD
C 3
11
03
7 F
00
07
2C
DC
31
1 0
38
F0
00
6
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 6/8
6
Logic relays
Ordering details
Ordering details - CL-LA...
Description Type Order code Price
1 pce
Weight
(1 pce)
kg (lb)
Software for programming and control of CL
range devices. Installation CD-ROM for Micro-
soft WindowsTM.
CL-LAS.PS002 1SVR440799R80000.10
(0.21)
Memory module for logic relays
Memory size: 32 kBCL-LAS.MD003 1SVR440799R7000 0.02 (0.04
Cable with serial interface to connect PC and
logic relay. Length: 2 mCL-LAS.TK001 1SVR440799R6000 0.10 (0.22)
Cable with USB interface to connect PC and
logic relay. Length: 2 mCL-LAS.TK002 1SVR440799R6100 0.06 (0.13)
Cable for point-to-point connection of remote-
display connection module and logic relay,
length: 5m, adaptable
CL-LAD.TK007 1SVR440899R6600 0.20 (0.44)
Fixing brackets for screw mounting of logic
relay, expansion, display base moduleCL-LAS.FD001 1SVR440799R5000 0.01 (0.01)
Spare plug (CL-LINK) for connection of logic
relay to expansionCL-LAS.TK011 1SVR440799R5100 0.10 (0.22)
Primary switch mode power supplies,
Rated input voltage: 100-240 V AC
Rated output voltage/current: 24 V DC / 0.42 A
CP-D 24/0.421) 1SVR427041R0000 0.06 (0.13)
Primary switch mode power supplies,
Rated input voltage: 100-240 V AC
Rated output voltage/current: 24 V DC / 1.3 A
CP-D 24/1.32) 1SVR427043R0100 0.19 (0.41)
1) replaces CL-LAS.SD001, technical data see chapter “Primary switch mode power supplies”2) replaces CL-LAS.SD002, technical data see chapter “Primary switch mode power supplies”
CL-LAS.PS002
CL-LAS.MD003
CL-LAS.TK001
2C
DC
31
1 0
12
F0
00
72
CD
C 3
11
01
3 F
00
07
2C
DC
31
1 0
14
F0
00
7
6/9 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C02010
6
Ordering details - Display systems
Rated opera-
tional voltage
Description Type Order code Price
1 pce
Weight
(1 pce)
kg (lb)
-
Display module
Graphic display 132 x 64
pixel
CL-LDD.XK 1SVR440839R4500 0.14 (0.30)
-
Display module
Graphic display 132 x 64
pixel, with keypad
CL-LDD.K 1SVR440839R4400 0.13 (0.29)
24 V DCDisplay base module CPU /
power supply
CL-LDC.LDC2 1SVR440821R0000
0.16 (0.36)
100-240 V AC CL-LDC.LAC2 1SVR440823R0000
24 V DCDisplay base module
CPU / power supply,
networking-compatible
(CL-NET)
CL-LDC.LNDC2 1SVR440821R1000
0.17 (0.38)
100-240 V AC CL-LDC.LNAC2 1SVR440823R1000
100-240 V ACDisplay I/O module
12 inputs, 4 relay outputs
CL-LDR.16AC2 1SVR440853R0000
0.17 (0.38)
24 V DC CL-LDR.16DC2 1SVR440851R0000
24 V DC
Display I/O module
12 inputs, 4 relay outputs,
1 analog output
CL-LDR.17DC2 1SVR440851R2000 0.17 (0.38)
24 V DC
Display I/O module
12 inputs, 4 transistor
outputs
CL-LDT.16DC2 1SVR440851R1000 0.14 (0.30)
24 V DC
Display I/O module
12 inputs, 4 transistor out-
puts, 1 analog output
CL-LDT.17DC2 1SVR440851R3000 0.14 (0.30)
Logic relays
Ordering details - Display systems
CL-LDD.K
CL-LDC.LN..
2C
DC
31
1 0
28
F0
00
62
CD
C 3
11
03
1 F
00
06
Ordering details - CL-LAD...
Description Type Order code Price
1 pce
Weight
(1 pce)
kg (lb)
Memory module for display base modules
Memory size: 256 kBCL-LAD.MD004 1SVR440899R7000 0.02 (0.03)
Cable with serial interface to connect PC and
display base moduleCL-LAD.TK001 1SVR440899R6000 0.11 (0.23)
Cable with USB interface to connect PC and
display base moduleCL-LAD.TK011 1SVR440899R6700
Network cable (CL-NET) to connect 2 display
base modules Length: 0.3 mCL-LAD.TK002 1SVR440899R6100 0.05 (0.12)
Network cable (CL-NET) to connect 2 display
base modules Length: 0.8 mCL-LAD.TK003 1SVR440899R6200 0.07 (0.14)
Network cable (CL-NET) to connect 2 display
base modules Length: 1.5 mCL-LAD.TK004 1SVR440899R6300 0.08 (0.18)
Cable for point-to-point connection of remote
display connection modules and display base
module, length adaptable, Length: 5 m
CL-LAD.TK005 1SVR440899R6400 0.20 (0.44)
Cable for point-to-point connection of 2
display base modules, length adaptable.
Length: 5 m
CL-LAD.TK006 1SVR440899R6500 0.12 (0.26)
Termination resistor, content: 2 pieces CL-LAD.TK009 1SVR440899R6900 0.01 (0.02)
Protective cover, transparent, for harsh envi-
ronmental conditions and application in the
food industry
CL-LAD.FD001 1SVR440899R1000 0.03 (0.07)
Protective cover, transparent and sealable CL-LAD.FD011 1SVR440899R2000 0.03 (0.07)
Assembly tool for mounting of display mod-
ulesCL-LAD.FD002 1SVR440899R3000
CL-LAD.MD004
CL-LAD.TK001
CL-LAD.TK002
2C
DC
31
1 0
18
F0
00
7
2C
DC
31
1 0
19
F0
00
72
CD
C 3
11
02
0 F
00
06
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 6/10
6
Logic relays
Technical data
Data at Ta = 25 °C and rated values, if nothing else indicated.
Type CL-LSR.C...12DC1 CL-LSR....12DC2 CL-LST.C...12DC2
CL-LSR.C...12AC1 CL-LSR...12AC2
Input circuit - supply circuitRated operational voltage U
e12 V DC 24 V DC 24 V AC 100-240 V AC
Rated operational voltage tolerance -15...+30 % -15...+20 % -15...+10 %Operational voltage range 10.2-15.6 V DC 20.4-28.8 V DC 20.4-26.4 V AC 85-264 V ACRated frequency 0 Hz 50/60 HzRated frequency tolerance - ±5 %Residual ripple � 5 % -Input current at 12 V DC typ. 140 mA - - -
at 24 V DC - typ. 80 mA - -at 24 V AC - - typ. 200 mA -
at 115/120 V AC (60 Hz) - - - typ. 40 mAat 230/240 V AC (50 Hz) - - - typ. 20 mA
Power failure buffering (IEC/EN 61131-2) 10 ms 20 msPower dissipation at 12 V DC typ. 2 W - - -
at 24 V DC - typ. 2 W - -at 24 V AC - - typ 5 VA -
at 115/120 V AC - - - typ. 5 VAat 230/240 V AC - - - typ. 5 VA
Type CL-LMR.C...18DC1 CL-LMR.C...18DC2 CL-LMT.C...20DC2
CL-LMR.C...18AC1 CL-LMR.C...18AC2
Input circuit - supply circuitRated operational voltage U
e12 V DC 24 V DC 24 V AC 100-240 V AC
Rated operational voltage tolerance -15...+30 % -15...+20 % -15...+10 %Operational voltage range 10.2-15.6 V DC 20.4-28.8 V DC 20.4-26.4 V AC 85-264 V ACRated frequency 0 Hz 50/60 HzRated frequency tolerance - ±5 %Residual ripple � 5 % -Input current at 12 V DC typ. 200 mA - - -
at 24 V DC - typ. 140 mA - -at 24 V AC - - typ. 300 mA -
at 115/120 V AC (60 Hz) - - - typ. 70 mAat 230/240 V AC (50 Hz) - - - typ. 35 mA
Power failure buffering (IEC/EN 61131-2) 10 ms 20 msPower dissipation at 12 V DC typ. 3.5 W - - -
at 24 V DC - typ. 3.5 W - -at 24 V AC - - typ. 7 VA -
at 115/120 V AC - - - typ. 10 VAat 230/240 V AC - - - typ. 10 VA
Type CL-LER.18DC2 CL-LET.20DC2
CL-LER.18AC2
Input circuit - supply circuit
Rated operational voltage Ue
24 V DC 100-240 V AC
Rated operational voltage tolerance -15...+20 % -15...+10 %Operational voltage range 20.4-28.8 V DC 85-264 V ACRated frequency 0 Hz 50/60 HzRated frequency tolerance - ±5 %Residual ripple � 5 % -Input current at 24 V DC typ. 140 mA -
at 115/120 V AC (60 Hz) - typ. 70 mAat 230/240 V AC (50 Hz) - typ. 35 mA
Power failure buffering (IEC/EN 61131-2) 10 ms 20 msPower dissipation at 24 V DC typ. 3.4 W -
at 115/120 V AC - typ. 10 VAat 230/240 V AC - typ. 10 VA
6/11 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C02010
6
Logic relays
Technical data
Data at Ta = 25 °C and rated values, if nothing else indicated.
Type CL-LSR.C...12DC1 CL-LSR....12DC2 CL-LST.C...12DC2
CL-LSR.C...12AC1 CL-LSR.C...12AC2
Input circuit - Digital inputs 12 V DC 24 V DC 24 V AC 115 / 230 V AC
Number 8Inputs can be used as analog inputs 2 (I7, I8) -Indication of operational states LCD-Display (if existing)Electrical isolation from voltage supply no
between digital inputs nofrom the outputs yes
Rated operational voltage U
e
12 V DC 24 V DC 24 V ACU
e on „0“ signal 4 V DC (I1-I8) < 5 V DC (I1-I8) 0-6 V AC (sinusoidal) 0-40 V AC (sinusoidal)
Ue on „1“ signal 8 V DC (I1-I8) > 15 V DC (I1-I6),
> 8 V DC (I7, I8)> 9.5 V DC, 14-26.4 V AC (sinusoidal) (I1-I6), > 7 V AC (sinusoidal) (I7,I8)
79-264 V AC (sinusoidal)
Rated frequency - 50-60 HzInput current on „1“ signal
3.3 mA (at 12 V DC, I1-I6), 1.1 mA (at 12 V DC, I7, I8)
3.3 mA (at 24 V DC, I6-I7), 2.2 mA (at 24 V DC, I7, I8)
4 mA (at 24 V AC, 50 Hz, I1-I6),2 mA (at 24 V AC, 50 Hz, I7,I8),2 mA (at 24 V DC, I7, I8)
6x0.25 mA (at 115 V AC, 60 Hz, I1-I6), 6x0.5 mA (at 230 V AC, 50 Hz, I1-I6)2x4 mA (at 115 V AC, 60 Hz, I7, I8), 2x6 mA (at 230 V AC, 50 Hz, I7, I8)
Time delay from „0“ to „1“
debounce ON 20 ms 80 ms (at 50 Hz), 66 2/3 ms (at 60 Hz)debounce OFF typ. 0.3 ms (I1-I6),
typ. 0.35 ms (I7, I8)typ. 0,25 ms (I1-I8) 20 ms (at 50 Hz), 16 2/3 ms (at 60 Hz)
Time delay from „1“ to „0“
debounce ON 20 ms 80 ms (at 50 Hz), 66 2/3 ms (at 60 Hz)
80 ms (at 50 Hz, I1-I6), 66 2/3 ms (at 60 Hz, I1-I6)160 ms (at 50 Hz, I7, I8), 150 ms (at 60 Hz, I7, I8)
debounce OFF typ. 0.3 ms (I1-I6),typ. 0.15 ms (I7, I8)
- 20 ms (at 50 Hz), 16 2/3 ms (at 60 Hz)
20 ms (at 50 Hz, I1-I6), 16 2/3 ms (at 60 Hz, I1-I6)100 ms (at 50 Hz, I7. I8), 100 ms (at 60 Hz, I7, I8)
Cable length (unshielded) 100 m - -Maximum cable length per input - 40 m 40 m (I1-I6),
100 m (I7, I8)Frequency counter Number 2 (I3, I4) - -
counting frequency < 1 kHz - -pulse shape square-wave - -
pulse / pause ratio 1:1 - -Rapid counter inputs Number 2 (I1, I2) - -
counting frequency < 1 kHz - -pulse shape square-wave - -
pulse / pause ratio 1:1 - -Cable length (shielded) < 20 m - -Input circuit - Analog inputs
Number 2 (I7, I8) -Electrical isolation from voltage supply no -
from the digital inputs no -from the outputs yes -
from PC interface, memory
module, CL-NET, CL-LINK
no -
Input type DC voltage -Signal range 0-10 V DC -Resolution analog 0.01 V -
digital 0.01 V; 10 Bit (value 1-1023) -Input impedance 11.2 k� -Accuracy of the actual value
two CL devices ±3 % -within one device ±2 %, ±0.12 V -
Conversion time analog/digital
Input delay ON 20 ms -Input delay OFF each cycle -
Input current < 1 mA -Cable length (shielded) < 30 m -
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 6/12
6
Logic relays
Technical data
Data at Ta = 25 °C and rated values, if nothing else indicated.
Type CL-LMR.C...18DC1 CL-LMR.C...18DC2 CL-LMT.C...20DC2
CL-LMR.C...18AC1 CL-LMR.C...18AC2
Input circuit - Digital inputs 12 V DC 24 V DC 24 V AC 115 / 230 V AC
Number 12Inputs can be used as analog inputs 4 (I7, I8, I11, I12) -Indication of operational states LCD-Display (if existing)Electrical isolation from voltage supply no
between digital inputs nofrom the outputs yesfrom PC interface,
memory module, CL-NET, CL-LINK
no yes
Rated operational voltage U
e
12 V DC 24 V DC 24 V ACU
e on „0“ signal 4 V DC (I1-I12) < 5 V DC
(I1-I12, R1-R12)0-6 V AC (sinusoidal) 0-40 V AC (sinusoidal)
Ue on „1“ signal 8 V DC (I1-I12) > 15 V DC (I1-I6, I9, I10)
> 8 V DC (I7, I8, I11, I12)> 9.5 V DC, 14-26.4 V AC (sinusoidal) (I1-I6, I9, I10) > 7 V AC (sinusoidal) (I7,I8; I11, I12)
79-264 V AC (sinusoidal)
Rated frequency - 50-60 HzInput current on „1“ signal
3.3 mA (at 12 V DC, I1-I6, I9-I12),1.1 mA (at 12 V DC, I7, I8)
3.3 mA (at 24 V DC, I1-I6, I9, I10), 2.2 mA (at 24 V DC, I7, I8, I11, I12)
4 mA (at 24 V AC, 50 Hz, I1-I6, I9, I10), 2 mA (at 24 V AC, 50 Hz, I7, I8, I11, I12), 2 mA (at 24 V DC, I7, I8, I11, I12)
6x0.25 mA (at 115 V AC, 60 Hz, I1-I6), 6x0.5 mA (at 230 V AC, 50 Hz, I1-I6) 2x4 mA (at 115 V AC, 60 Hz, I7, I8), 2x6 mA (at 230 V AC, 50 Hz, I7, I8), 4x0.25 mA (at 115 V AC, 60 Hz, I9-I12), 4x0.5 mA (at 230 V AC, 50 Hz, I9-I12)
Time delay from „0“ to „1“
debounce ON 20 ms 80 ms (at 50 Hz), 66 2/3 ms (at 60 Hz)debounce OFF typ. 0.3 ms (I1-I6, I9, I10),
typ. 0.35 ms (I7, I8, I11, I12)typ. 0.25 ms 20 ms (at 50 Hz), 16 2/3 ms (at 60 Hz)
Time delay from „1“ to „0“
debounce ON 20 ms 80 ms (at 50 Hz), 66 2/3 ms (at 60 Hz)debounce OFF typ. 0.4 ms (I1-I6, I9, I10),
typ. 0.35 ms (I7, I8, I11, I12)- 20 ms (at 50 Hz), 16 2/3 ms (at 60 Hz)
Cable length (unshielded) 100 mMaximum cable length per input max. 40 m,
typ. 40 m (I9, I10)typ. 40 m (I1-I6, I9-I12), typ. 100 m (I7, I8)
Frequency counter number 2 (I3, I4) - -counting frequency < 1 kHz - -
pulse shape square-wave - -pulse / pause ratio 1:1 - -
Rapid counter inputs number 2 (I1, I2) - -counting frequency < 1 kHz - -
pulse shape square-wave - -pulse / pause ratio 1:1 - -
Cable length (shielded) < 20 m - -Input circuit - Analog inputs
Number 4 (I7, I8, I11, I12) -Electrical isolation from voltage supply no -
from the digital inputs no -from the outputs yes -
from PC interface, memory
module, CL-NET, CL-LINK
no -
Input type DC voltage -Signal range 0-10 V DC -Resolution analog 0.01 V -
digital 0.01 V; 10 Bit (value 1-1023) -Input impedance 11.2 k� -Accuracy of the actual value
two CL devices ±3 % -within one device ±2 %, ±0.12 V -
Conversion time analog/digital
Input delay ON 20 ms -Input delay OFF each cycle -
Input current < 1 mA -Cable length (shielded) < 30 m -
6/13 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C02010
6
Logic relays
Technical data
Data at Ta = 25 °C and rated values, if nothing else indicated.
Type CL-LER.18DC2, CL-LET.20DC2 CL-LER.18AC2Input circuit - Digital inputs 24 V DC 115 / 230 V ACNumber 12
Inputs can be used as analog inputs -
Indication of operational states -
Electrical isolation from voltage supply no
between digital inputs no
from the outputs yes
from PC interface, memory
module, CL-NET, CL-LINK
no
Rated operational voltage U
e
24 V DC
Ue on „0“ signal < 5 V DC (I1-I12, R1-R12) 0-40 V AC (sinusoidal)
Ue on „1“ signal - 79-264 V AC (sinusoidal)
Rated frequency - 50-60 Hz
Input current on „1“ signal
3.3 mA (at 24 V DC, R1-R12) 12x0.25 mA (at 115 V AC, 60 Hz, R1-R12), 12x0.5 mA (at 230 V AC, 50 Hz, R1-R12)
Time delay from „0“ to „1“
debounce ON 20 ms 80 ms (at 50 Hz, I1-I12, R1-R12), 66 2/3 ms (at 60 Hz, I1-I12, R1-R12)
debounce OFF typ. 0.25 ms (R1-R12) 20 ms (at 50 Hz, I1-I12, R1-R12), 16 2/3 ms (at 60 Hz, I1-I12, R1-R12)
Time delay from „1“ to „0“
debounce ON 20 ms 80 ms (at 50 Hz, I1-I12, R1-R12), 66 2/3 ms (at 60 Hz, I1-I12, R1-R12)
debounce OFF - 20 ms (at 50 Hz, I1-I12, R1-R12), 16 2/3 ms (at 60 Hz, I1-I12, R1-R12)
Cable length (unshielded) 100 m -
Maximum cable length per input - typ. 40 m (I1-I6, I9-I12, R1-R12), typ. 100 m (I7, I8)
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 6/14
6
Logic relays
Technical data
Data at Ta = 25 °C and rated values, if nothing else indicated.
Type CL-LSR... CL-LMR...
CL-LER...
CL-LER.2O
Output circuit - Relay outputsNumber 4 6 2
Outputs in groups of 1 2
Parallel switching of outputs to increase capacity not permissible
Fusing of the output relay circuit-breaker B16 or fuse 8 A (slow-acting)
Electrical isolation from voltage supply yes
from the inputs yes
from PC interface, memory module, CL-NET, CL-LINK
no
protective separation 300 V AC
basic isolation 600 V AC
Mechanical lifetime 10x106 switching cycles
Rung conventional thermal current (10 A UL) 8 A
recommended for load 12 V AC/DC > 500 mA
short-circuit proof cos = 1; characteristic B16 at 600 A
16 A
short-circuit proof cos = 0,5 up to 0,7; characteristic B16 at 900 A
16 A
Rated impulse withstand voltage Uimp
contact-coil
6 kV
Rated operational voltage Ue
250 V AC
Rated insulation voltage Ui
250 V AC
Protective separation (EN 50178)
between coil and contact 300 V AC
between two contacts 300V AC
Making capacity AC-15, 250 V AC, 3 A (600 ops./h) 300.000 switching cycles
DC13, L/R � 150 ms, 24 V DC, 1 A (500 ops./h)
200.000 switching cycles
Breaking capacity AC-15, 250 V AC, 3 A (600 ops./h) 300.000 switching cycles
DC13, L/R � 150 ms, 24 V DC, 1 A (500 ops./h)
200.000 switching cycles
Incandesent lamp load 1000 W at 230/240 V AC 25.000 switching cycles
500 W at 115/120 V AC 25.000 switching cycles
Fluorescent lamp load 10 x 58 W at 230/240 V AC with electrical control gear
25.000 switching cycles
10 x 58 W at 230/240 V AC uncompensated
25.000 switching cycles
1 x 58 W at 230/240 V AC conventional compensated
25.000 switching cycles
Switching frequency mechanical operations 10x106
switching frequency 10 Hz
resistive load / lamp load 2 Hz
inductive load 0.5 Hz
UL/CSAContinuous current at 240 V 10 A AC
Continuous current at 24 V 8 A DC
AC Utilization catagory (Control Circuit Rating Codes)
B 300 Light Pilot Duty
max. rated operational voltage 300 V AC
max. continuous thermal current cos = 1 at B 300
5 A
max. making / breaking apparent power (Make/Break) cos 1 at B 300
3600/360 VA
DC Utilization catagory (Control Circuit Rating Codes)
R 300 Light Pilot Duty
max. rated operational voltage 300 V DC
max. continuous thermal current at R 300 1 A
max. making / breaking apparent power (Make/Break) at R 300
28/28 VA
6/15 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C02010
6
Logic relays
Technical data
Data at Ta = 25 °C and rated values, if nothing else indicated.
Type CL-LST... CL-LMT... CL-LET...Output circuit - Transistor outputsNumber 4 8
Rated operational voltage Ue
24 V DC
Operational voltage range 20.4-28.8 V DC
Residual ripple � 5 %Supply current on „0“ signal typ. 9 mA / max. 16 mA typ. 18 mA / max. 32 mA
on „1“ signal typ. 12 mA / max. 22 mA typ. 24 mA / max. 44 mA
Reverse voltage protection yes (Attention: If supply voltage is reversed, applying voltage at the outputs, causes a short circuit.)
Electrical isolation from voltage supply yes
from the inputs yes
from PC interface, memory module, CL-NET, CL-LINK
-
Rated operational current Ie on„1“ signal DC max. 0.5 A
Lamp load without Rv
5 W
Residual current on „0“ signal per channel < 0.1 mA
Max. output voltage on „0“ signal at external load < 10 M� 2.5 V
on „1“ signal at Ie = 0.5 A U = Ue - 1 V
Short-circuit protection yes, thermal (analysis results from diagnosis input I16, I15; R15, R16)
Short-circuit tripping current for Ra � 10 m� 0.7 A � I
e � 2 A per output
Total short-circuit current 8 A 16 A
Peak short-circuit current 16 A 32 A
Thermal tripping yes
Max. switching frequency with constant resistive load RL < 100 k�
(depending on active channels and their load)40.000 switching cycles/h
Parallel connection of outputs with resistive load, inductive load with external
suppressor, combination within one group
group 1: Q1-Q4 group 1: Q1-Q4, group 2: Q5-Q8
group 1: S1-S4, group 2: S5-S8
number of outputs max. 4
max. total current 2 A (Attention! Outputs must be actuated simultaneously and for the same length of time.)
Indication of operational states of the outputs LCD-Display (if existing)
Inductive load1) without external suppressor
T0.95
= 1 ms, R = 48 �, L = 16 mH
utilization factor 0.25 g
duty time 100 %
max. switching frequency f = 0,5 Hz (max. duty time = 50 %)
1500 switching cycles
DC13, T
0.95 = 72 ms,
R = 48 �, L = 1.15 H
utilization factor 0.25 g
duty time 100 %
max. switching frequency f = 0,5 Hz (max. duty time = 50 %)
1500 switching cycles
T0.95
= 15 ms, R = 48 �, L = 0.24 H
utilization factor 0.25 g
duty time 100 %
max. switching frequency f = 0,5 Hz (max. duty time = 50 %)
1500 switching cycles
Inductive load1) with external suppressor
demand factor 1 g
duty time 100 %
max. switching frequency max. duty time
depends on suppressor
1) For inductive loading, without external suppression of the transistor outputs, the following applies:
T0.95
= time in ms, until 95 % of the steady-state current is achieved. T0.95
3 × T0.65
= 3 × L/R.
Data transfer rate in the CL-NET network: bus lengths of 40 m and over only attainable with cables with additional cross-section and connection adapter.
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 6/16
6
Logic relays
Technical data
Data at Ta = 25 °C and rated values, if nothing else indicated.
Type CL-LSR..., CL-LST... CL-LMR... CL-LMT..
CL-LET.., CL-LER.18..
CL-LER.2O
CL-LEC.CI000General dataDimensions (W x H x D) 71.5 mm x 90 mm x
58 mm (2.81 inch x 3.54 inch x 2.28 inch)
107.5 mm x 90 mm x 58 mm (4.23 inch x 3.54 inch x 2.28 inch)
35.5 mm x 90 mm x 58 mm (1.40 inch x 3.54 inch x 2.28 inch)
Weight 0.2 kg (0.44 lb) 0.3 kg (0.66 lb) 0.07 kg (0.15 lb)
Mounting DIN rail (IEC/EN 60715), 35 mm or screw mounting with fixing brackets CL-LAS.FD001 (accessories)
Mounting position horizontal / vertical
Electrical connectionWire size rigid 0.2-4 mm2 (22–12 AWG)
fine-strand with wire end ferrule
0.2-2.5 mm2 (22–12 AWG)
Max. tightening torque 0.6 Nm
Environmental dataAmbient temperature range operation -25...+55 °C, cold acc. to IEC 60068-2-1, heat acc. to IEC 60068-2-2
storage -40...+70 °C
LCD-Display (clearly legible) 0...+55 °C
Condensation avoid condensation with suitable methods
Humidity, no condensation (IEC/EN 60068-2-30) 5-95 %
Air pressure (operation) 795-1080 hPa
Degree of protection (IEC/EN 60529) IP20
Vibration (IEC/EN 60068-2-6) 10-57 Hz (constant amplitude 0.15 mm), 57-150 Hz (constant acceleration 2 g)
Shock resistance (half-sine 15 g / 11 ms) (IEC/EN 60068-2-27) 18 Shocks
Drop (IEC/EN 60068-2-31) height of fall 50 mm
Free fall, packaged (IEC/EN 60068-2-32) 1 m
Insulation dataOvervoltage category II
Pollution degree (DIN EN 60947) 2
Rating of air and creepage distances EN 50178, UL 508, CSA C22.2, No. 142
Insulation resistance EN 50178
StandardsStandards and directives EN 55011, EN 55022, IEC/EN 61000-4, IEC 60068-2-6, IEC 60068-2-27
Electromagnetic compatibilityInterference immunity
electrostatic discharge (ESD) IEC/EN 61000-4-2 Level 3 (air discharge 8 kV, contact discharge 6 kV)
electromag. field (HF radiation resistance) IEC/EN 61000-4-3 10 V/m
fast transients (Burst) IEC/EN 61000-4-4 Level 3 (supply cable 2 kV, signal lines 2 kV)
powerful impulses (Surge) IEC/EN 61000-4-5 supply cable symmetrical (AC) 2 kV, Level 2 (supply cable symmetrical (DC) 0.5 kV)
HF line emission IEC/EN 61000-4-6 10 V
Interference suppression (EN 55011, EN 55022) class B
Real time clockBack-up time see diagram -
Accuracy typ. ±5 (±0.5 h/year) -
Repeat accuracy of the time relayAccuracy (from value) ±1 -
Resolution range „S“ 10 ms -
range „M:S“ 1 s -
range „H:M“ 1 min -
Retention behaviourWrite cycles of retention memory (minimum) 1.000.000 (106) -
180200
160140120100806040200
55 ˚C
25 ˚C
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Buf
fer
time
(hou
rs)
2CD
C 3
12 0
23 F
0206
Operating time (years)
Technical diagramBack-up time of the real time clock
6/17 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C02010
6
Logic relays
Technical data
Data at Ta = 25 °C and rated values, if nothing else indicated.
Type CL-LDD...Input circuit - Supply circuitPower failure buffering (IEC/EN 61131-2) 10 ms
General dataDimensions (W x H x D) with keypad:
86.5 x 86.5 x 21.5 mm (3.41 x 3.41 x 0.85 inch)without keypad: 86.5 x 86.5 x 20 mm (3.41 x 3.41 x 0.79 inch)
Weight 0.13 kg (0.29 lb)Mounting 2 x 22.5 mm, with 2 retainers screwedMounting position horizontal / vertical
Environmental dataAmbient temperature range operation -25...+55 °C (cold acc. to IEC 60068-2-1, heat acc. to IEC
60068-2-2)storage -40...+70 °C
LCD-Display (clearly legible) -5...+50 °C,-10...0 °C (with backlit / continuous operation)
Condensation avoid condensation with suitable methodsHumidity, no condensation (IEC/EN 60068-2-30) 5-95 %Air pressure (operation) 795-1080 hPaDegree of protection (IEC/EN 60529) IP65Vibration (IEC/EN 60068-2-6) 10-57 Hz (constant amplitude 0.15 mm), 57-150 Hz (constant
acceleration 2 g)Shock resistance (half-sine 15 g / 11 ms) (IEC/EN 60068-2-27) 18 ShocksDrop (IEC/EN 60068-2-31) height of fall 50 mmFree fall, packaged (IEC/EN 60068-2-32) 1 m
Insulation dataPollution degree (DIN EN 60947) 3Rating of air and creepage distances EN 50178, UL 508, CSA 22.2, No 142Insulation resistance EN 50178
StandardsStandards and directives EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4,
IEC 60068-2-6, IEC 60068-2-27
Electromagnetic compatibilityInterference immunityelectrostatic discharge (ESD) IEC/EN 61000-4-2 Level 3 (air discharge 8 kV, contact discharge 6 kV)electromag. field (HF radiation resistance) IEC/EN 61000-4-3 10 V/mfast transients (Burst) IEC/EN 61000-4-4 Level 3 (supply cable 2 kV, signal lines 2 kV)powerful impulses (Surge) IEC/EN 61000-4-5 Level 3 (supply cable symmetrical 2 kV, CL-LDC.L...AC2)
Level 2 (0.5 kV supply cable symmetrical, CL-LDC.L...AC2)HF line emission IEC/EN 61000-4-6 10 VInterference suppression (EN 55011, EN 55022) class B
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 6/18
6
Logic relays
Technical data
Data at Ta = 25 °C and rated values, if nothing else indicated.
Type CL-LDC.SDC2 CL-LDC.SAC2 CL-LDC.LDC2 CL-LCD.LAC2 CL-LDC.LNDC2 CL-LDC.LNAC2Input circuit - Supply circuitRated operational voltage U
e24 V DC 100-240 V AC 24 V DC 100-240 V AC 24 V DC 100-240 V AC
Rated operational voltage tolerance -15...+20 % -15...+10 % -15...+20 % -15...+10 % -15...+20 % -15...+10 %
Operational voltage range 20.4-28.8 V DC 85-264 V AC 20.4-28.8 V DC 85-264 V AC 20.4-28.8 V DC 85-264 V AC
Frequency 0 Hz 50/60 Hz 0 Hz 50/60 Hz 0 Hz 50/60 Hz
Frequency tolerance - ± 5 % - ± 5 % - ± 5 %
Residual ripple � 5 % - � 5 % - � 5 % -
Input current at 24 V DC typ. 185 mA - typ. 200 mA - typ. 200 mA -
at 115/120 V AC (60 Hz) - typ. 90 mA - typ. 90 mA - typ. 90 mA
at 230/240 V AC (50 Hz) - typ. 60 mA - typ. 60 mA - typ. 60 mA
Power failure buffering (IEC/EN 61131-2) 10 ms
Power dissipation at 24 V DC 1.5 W - 3.4 W - 3.4 W -
at 115/120 V AC - typ. 11 VA - typ. 11 VA - typ. 11 VA
at 230/240 V AC - typ. 15 VA - typ. 15 VA - typ. 15 VA
Network - point-to-point connectionNumber of stations 1 -
Data transfer rate CL-LS..., CL-LM... 9.6 kBaud -
CL-LDD 19.2 kBaud -
Distance max. 5 m -
Electrical isolation to voltage supply yes -
to connected device yes -
Termination system spring-type terminal -
Network - CL-NETNumber of stations max. 1 - max. 8
Data transfer rate 6 m - 1000 kBit/s
25 m - 500 kBit/s
40 m - 250 kBit/s
125 m - 125 kBit/s
300 m - 50 kBit/s
700 m - 20 kBit/s
1000 m - 10 kBit/s
Electrical isolation to voltage supply - yes
to inputs - yes
to outputs - yes
to PC interface, memory module, CL-NET, CL-LINK
- yes
Bus terminator (first and last station) - yes
Termination system - RJ45, 8 pole
General dataDimensions (W x H x D) 75 x 58 x 36.2 mm
(2.95 x 2.28 x 1.43 inch)107.5 x 90 x 30 mm (4.23 x 3.54 x 1.18 inch)
Weight 0.164 kg (0.36 lb) 0.145 kg (0.32 lb)
Mounting plugged onto CL-LDD plugged onto CL-LDD or on DIN rail (IEC/EN 60715)
Mounting position
Electrical connection - Supply circuitWire size fine-strand with wire
end ferrule0.2 mm2 / 2.5 mm2 (24-12 AWG)
rigid 0.2 mm2 / 4 mm2 (24-12 AWG)
Electrical connection - Data cable
Wire size fine-strand with wire end ferrule
0.08 mm2 / 1.5 mm2 (28-12 AWG)
- 0.2 mm2 / 2.5 mm2 (24-12 AWG)
rigid 0.08 mm2 / 2.5 mm2 (28-12 AWG)
- 0.2 mm2 / 4 mm2 (24-12 AWG)
Environmental dataAmbient temperature range operation -25...+55 °C (cold acc. to IEC 60068-2-1, heat acc. to IEC 60068-2-2)
storage -40...+70 °C
Condensation avoid condensation with suitable methods
Humidity, no condensation (IEC/EN 60068-2-30) 5-95 %
Air pressure (operation) 795-1080 hPa
Degree of protection (IEC/EN 60529) IP20
Vibration (IEC/EN 60068-2-6) 10-57 Hz (constant amplitude 0.15 mm), 57-150 Hz (constant acceleration 2 g)
6/19 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C02010
6
Logic relays
Technical data
Data at Ta = 25 °C and rated values, if nothing else indicated.
Type CL-LDC.
SDC2
CL-LDC.
SAC2
CL-LDC.
LDC2
CL-LCD.
LAC2
CL-LDC.
LNDC2
CL-LDC.
LNAC2Shock (half-sine 15 g / 11 ms) (IEC/EN 60068-2-27) 18 ShocksDrop (IEC/EN 60068-2-31) height of fall 50 mmFree fall, packaged (IEC/EN 60068-2-32) 1 m
Insulation dataDegree of protection (DIN EN 60947) 2Rating of air and creepage distances EN 50178, UL 508, CSA 22.2, No 142Isolation resistance EN 50178
StandardsStandards and directives EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, IEC 60068-2-6, IEC 60068-
2-27
Electromagnetical compatibilityInterference immunityelectrostatic discharge (ESD) IEC/EN 61000-4-2 Level 3 (air discharge 8 kV, contact discharge 6 kV)electromag. field (HF radiation resistance)
IEC/EN 61000-4-3
10 V/m
fast transients (Burst) IEC/EN 61000-4-4 Level 3 (supply cable 2 kV, signal lines 2 kV)powerful impulses (Surge) IEC/EN 61000-4-5 Level 3 (supply cable symmetrical 2 kV, CL-LDC.L...AC2)
Level 2 (1 kV supply cable symmetrical)
Level 2 (0.5 kV supply cable symmetrical, CL-LDC.L...AC2)
HF line emission IEC/EN 61000-4-6 10 VInterference suppression (EN 55011, EN 55022) class B
Real time clockBack-up time - see diagramAccuracy - typ. ± 5 s/day (± 0,5 h/year)
Repeat accuracy of the time relayAccuracy (from value) - ± 0.02 %Resolution range „S“ - 5 ms
range „M:S“ - 1 srange „H:M“ - 1 min
Retention behaviourWrite cycles of retention memory (minimum) - 1010 (read/ write cycles)
180200
160140120100806040200
55 ˚C
25 ˚C
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Buf
fer
time
(hou
rs)
2CD
C 3
12 0
23 F
0206
Operating time (years)
Technical diagramBack-up time of the real time clock
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 6/20
6
Logic relays
Technical data
Data at Ta = 25 °C and rated values, if nothing else indicated.
Type CL-LD...16DC2 CL-LD...17DC2 CL-LDR.16AC2Input circuit - Digital inputs 24 V DC 115/230 VNumber 12
Inputs can be used as analog inputs 4 (I7, I8, I11, I12) -
Indication of operational states - LCD-Display (if existing)
Electrical isolation from supply voltage no
from digital inputs no
from the outputs yes
from PC interface, memory module, CL-NET, CL-LINK
yes
Rated operational voltage Ue
24 V DC -
Ue on „0“ signal < 5 V DC (I1-I6, I9, I10), < 8 V DC (I7, I8, I11, I12) 0-40 V AC (sinusoidal)
Ue on „1“ signal > 15 V DC (I1-I6, I9, I10), > 8 V DC (I7, I8, I11, I12) 79-264 V AC
(sinusoidal)
Rated frequency 0 Hz 50-60 Hz
Input current on „1“ signal 3.3 mA (at 24 V DC, I1-I6, I9, I10),2.2 mA (at 24 V DC, I7, I8, I11, I12)
12x0.2 mA (at 115 V AC, 60 Hz, I1-I12),12x0.5 mA (at 230 V AC, 50 Hz, I1-I12)
Time delay from „0“ to „1“ debounce ON 20 ms 10 ms (at 50 Hz), 100 ms (at 60 Hz)
debounce OFF typ. 0.1 ms (I1-I4), typ. 0.25 ms (I5-I12) 10 ms (at 50 Hz), 100 ms (at 60 Hz)
Time delay from „1“ to „0“
debounce ON 20 ms 10 ms (at 50 Hz), 100 ms (at 60 Hz)
debounce OFF typ. 0.1 ms (I1-I4), typ. 0.4 ms (I5, I6, I9, I10), typ. 0.2 ms (I7, I8, I11, I12)
10 ms (at 50 Hz), 100 ms (at 60 Hz)
Cable length (unshielded) 100 m -
Maximum cable length per input - typ. 60 m
Frequency counter number 4 (I1, I2, I3, I4) -
counting frequency < 3 kHz -
pulse shape square-wave -
pulse / pause ratio 1:1 -
Incremental counter number 2 (I1 + I2, I3 + I4) -
counting frequency < 3 kHz -
pulse shape square-wave -
signal offset 90° -
pulse / pause ratio 1:1 -
Rapid counter inputs number 4 (I1, I2, I3, I4) -
counting frequency < 3 kHz -
pulse shape square-wave -
pulse / pause ratio 1:1 -
Cable length (shielded) < 20 m -
Input circuit - Analog inputsNumber 4 (I7, I8, I11, I12) -
Electrical isolation to voltage supply no -
to digital inputs no -
to outputs yes -
to PC interface, memory modul, CL-NET, CL-LINK
yes -
Input type DC voltage -
Signal range 0-10 V DC -
Resolution analog 0.01 V -
digital 0.01 V; 10 Bit (value 0-1023) -
Input impedance 11.2 k� -
Accuracy of the actual value two CL-LD... devices
± 3 % -
within one device ± 2 % -
Conversion time analog/digital each cycle -
Input current < 1 mA -
Cable length (shielded) < 30 m -
6/21 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C02010
6
Logic relays
Technical data
Data at Ta = 25 °C and rated values, if nothing else indicated.
Type CL-LD...16DC2 CL-LD...17DC2 CL-LDR.16AC2Output circuit - Analog outputsNumber - 1 -
Electrical separation from voltage supply - no -
from the digital inputs - no -
from the digital outputs - yes -
from PC interface, memory module, CL-NET, CL-LINK
- yes -
Output type - DC voltage -
Signal range - 0-10 V DC -
Max. output current - 0.01 A -
Burden resistance - 1 k� -
Overload and short-circuit protection - yes -
Resolution analog - 0.01 V DC -
digital - 10 Bit, (value: 0-1023) -
Setting time - 100 ms -
Accuracy -25...+55 °C - 2 % -
25 °C - 1 % -
Conversion time - each CPU cycle -
General dataDimensions (W x H x D) CL-LDR: 89 x 90 x 44 mm (3.5 x 3.54 x 1.73 inch)
CL-LDT (build-in): 89 x 90 x 25 mm (3.5 x 3.54 x 0.98 inch)
89 x 90 x 44 mm (3.5 x 3.54 x 1.73 inch)
Weight CL-LDR: 0.15 kg (0.33 lb) / CL-LDT: 014 kg (0.31 lb) 0.15 kg (0.33 lb)
Mounting snap-on power supply unit
Mounting position horizontal / vertical
Electrical connectionWire size fine-strand with wire end ferrule 0.2 mm2 / 2.5 mm2 (24-12 AWG)
rigid 0.2 mm2 / 4 mm2 (24-12 AWG)
Electrical connection - Data cableWire size fine-strand with wire end ferrule 0.08 mm2 / 1.5 mm2 (28-12 AWG)
rigid 0.08 mm2 / 2.5 mm2 (28-12 AWG)
Environmental dataAmbient temperature range operation -25...+55 °C (cold acc. to IEC 60068-2-1, heat acc. to IEC 60068-2-2)
storage -40...+70 °C
Condensation avoid condensation with suitable methods
Humidity, no condensation (IEC/EN 60068-2-30) 5-95 %
Atmospheric pressure (operation) 795-1080 hPa
Degree of protection (IEC/EN 60529) IP20
Vibration (IEC/EN 60068-2-6) 10-57 Hz (constant amplitude 0.15 mm), 57-150 Hz (constant acceleration 2 g)
Shock (half-sine 15 g / 11 ms) (IEC/EN 60068-2-27) 18 Shocks
Drop (IEC/EN 60068-2-31) height of fall 50 mm
Free fall, packaged (IEC/EN 60068-2-32) 1 m
Insulation dataPollution degree 2
Rating of air and creepage distances EN 50178, UL 508, CSA C22.2, No. 142
Isolation resistance EN 50178
StandardsStandards and directives EN 61000-6-1/-2/-3/-4, IEC/EN 61000-4, IEC 60068-2-6, IEC 60068-2-27
Electromagnetic compatibilityelectrostatic discharge (ESD) IEC/EN 61000-4-2 Level 3 (air discharge 8 kV, contact discharge 6 kV)
electromag. field (HF radiation res.) IEC/EN 61000-4-3 10 V/m
fast transients (Burst) IEC/EN 61000-4-4 Level 3 (supply cable 2 kV, signal cable 2 kV)
powerful impulses (Surge) IEC/EN 61000-4-5 2 kV (supply cable symmetrical), Level 2 (0.5 kV supply cable symmetrical)
HF line emission IEC/EN 61000-4-6 10 V
Interference suppression (EN 55011, EN 55022) class B
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 6/22
6
Logic relays
Technical data
Data at Ta = 25 °C and rated values, if nothing else indicated.
Type CL-LDR...Output circuit - Relay outputsNumber 4
Outputs in groups of -
Parallel switching of outputs to increase capacity not permissible
Fusing of the output relay circuit-breaker B16 or fuse 8 A (slow-acting)
Electrical isolation from voltage supply yes
from the inputs yes
from PC interface, memory module, CL-NET, CL-LINK
yes
protective separation 300 V AC
Basic isolation 600 V AC
Mechanical lifetime 10x106 switching cycles
Rung conventional thermal current (10 A UL) 8 A
recommended load 12 V AC/DC > 500 mA
short-circuit proof cos = 1; characteristic B16 at 600 A
16 A
short-circuit proof cos = 0.5 up to 0.7; characteristic B16 at 900 A
16 A
Rated impulse withstand voltage Uimp
contact-coil 6 kV
Rated operational voltage Ue
250 V AC
Rated insulation voltage Ui
250 V AC
Protective separation (EN 50178) between coil and contact 300 V AC
between two contacts 300V AC
Making capacity AC-15, 250 V AC, 3 A (600 ops./h) 300.000 switching cycles
DC13, L/R � 150 ms, 24 V DC, 1 A (500 ops./h) 200.000 switching cycles
Breaking capacity AC-15, 250 V AC, 3 A (600 ops./h) 300.000 switching cycles
DC13, L/R � 150 ms, 24 V DC, 1 A (500 ops/h) 200.000 switching cycles
Incandesent lamp load 1000 W at 230/240 V AC 25.000 switching cycles
500 W at 115/120 V AC 25.000 switching cycles
Fluorescent lamp load 10 x 58 W at 230/240 V AC with electrical control gear
25.000 switching cycles
10 x 58 W at 230/240 V AC uncompensated
25.000 switching cycles
1 x 58 W at 230/240 V AC conventional compensated
25.000 switching cycles
Switching frequency mechanical operations 10x106
switching frequency 10 Hz
resistive load / lamp load 2 Hz
inductive load 0.5 Hz
UL/CSAContinuous current at 240 V 10 A AC
Continuous current at 24 V 8 A DC
AC Utilization category (Control Circuit Rating Codes) B 300 Light Pilot Duty
max. rated operational voltage 300 V AC
max. continuous thermal current cos j = 1 at B 300 5 A
max. making / breaking apparent power (Make/Break) cos 1 at B 300
3600/360 VA
DC Utilization category (Control Circuit Rating Codes) R 300 Light Pilot Duty
max. rated operational voltage 300 V DC
max. continuous thermal current at R 300 1 A
max. making / breaking apparent power (Make/Break) at R 300
28/28 VA
6/23 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C02010
6
Logic relays
Technical data
Data at Ta = 25 °C and rated values, if nothing else indicated.
Type CL-LDT...
Output circuit - Transistor outputsNumber 4
Rated operational voltage Ue
24 V DC
Operational voltage range 20.4-28.8 V DC
Residual ripple -
Supply current on „0“ signal typ. 18 mA / max. 32 mA
on „1“ signal typ. 24 mA / max. 44 mA
Reverse voltage protection yes (Attention: If supply voltage is reversed, applying voltage at the outputs, causes a short circuit.)
Electrical isolation from voltage supply yes
from the inputs yes
from PC interface, memory module, CL-NET, CL-LINK
yes
Rated operational current Ie on„1“ signal DC max. 0.5 A
Lamp load without Rv
5 W (Q1-Q4)
Residual current on „0“ signal per channel < 0.1 mA
Max. output voltage on „0“ signal at external load < 10 M� 2.5 V
on „1“ signal at Ie = 0.5 A U = U
e - 1 V
Short-circuit protection thermal (Q1-Q4), (analysis results from diagnosis input I16)
Short-circuit tripping current for Ra � 10 m� 0.7 A � I
e � 2 A per output
Total short-circuit current 8 A
Peak short-circuit current 16 A
Thermal tripping yes
Max. switching frequency with constant resistive load RL < 100 k� (depending on
active channels and their load)40.000 switching cycles/h
Parallel connection of outputs with resistive load, inductive load with external suppressor, combination within one group
group 1: Q1-Q4
number of outputs max. 4
max. total current 2 A (Attention! Outputs must be actuated simultaneously and for the same length of time.)
Indication of operational states of the outputs LCD-Display (if existing)
Inductive load1) without external suppressor
T0.95
= 1 ms, R = 48 �, L = 16 mH
utilization factor 0.25 g
duty time 100 %
max. switching frequency f = 0,5 Hz (max. duty time = 50 %)
1500 switching cycles
DC13, T
0.95 = 72 ms,
R = 48 �, L = 1.15 H
utilization factor 0.25 g
duty time 100 %
max. switching frequency f = 0,5 Hz (max. duty time = 50 %)
1500 switching cycles
T0.95
= 15 ms, R = 48 �, L = 0.24 H
utilization factor 0.25 g
duty time 100 %
max. switching frequency f = 0,5 Hz (max. duty time = 50 %)
1500 switching cycles
Inductive load1) with external suppressor
demand factor 1 g
duty time 100 %
max. switching frequency max. duty time depends on suppressor1) For inductive loading, without external suppression of the transistor outputs, the following applies:
T0.95
= time in ms, until 95 % of the steady-state current is achieved. T0.95
3 × T0.65
= 3 × L/R.
Data transfer rate in the CL-NET network: bus lengths of 40 m and over only attainable with cables with additional cross-section and connection adapter.
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 6/24
6
Logic relays
Dimensional drawings90 10
2
110
71.5
M4
10.75 50
35.75
45
58
56.5
47.5
4.5
2C
DC
31
2 0
11
F0
b0
6
90 102
110
M4
107.5
75 16.2516.25
45
58
56.5
47.5
4.5
2C
DC
31
2 0
12
F0
b0
6
CL-LSR, CL-LST CL-LMR, CL-LMT
CL-LDD
3217
20 13.7
86.5
30
62
86.5
28.25 28.25
22.3
30
2C
DC
312 0
18 F
0b
06
90 102
110
45
58
56.5
47.5
4.5
7.5
35.5
7.5
M4
2C
DC
31
2 0
13
F0
b0
6
CL-LER.2O
90
88.2
107.5
20 43.2
33.7
2C
DC
312 0
14 F
0b
06
65.5
29.3 36.2
86.5
75
86.5
58
2C
DC
312 0
15 F
0b
06
90
88.1 19 25
2C
DC
312 0
16 F
0b
06
CL-LDC.S..
CL-LDR, CL-LDT
CL-LDD.K + CL-LDC.L.. + (CL-LDR or CL-LDT)
Dimensional drawings dimensions in mm
2/1 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
7
Index
Alphanumerical
Type Page Type Page Type Page Type Page
Numbers
A
ADP.01 ...................................... 1/40
ADP.01 ...................................... 1/40
ADP.01 .................................... 2/130
ADP.01 ...................................... 4/22
ADP.02 .................................... 2/130
B
BADH V0................................... 5/47
BADL V0 ................................... 5/47
BAM2 V0................................... 5/47
BJ 612-10 ................................. 5/36
BJ 612-10 ................................. 5/47
BJ 612-20 ................................. 5/36
BJ 612-20 ................................. 5/47
C
C512-24 ................................. 2/104
C512-D ................................... 2/104
C512-E ................................... 2/104
C512-W .................................. 2/104
C513-D ................................... 2/104
C513-E ................................... 2/104
C513-W .................................. 2/104
CC-E I/I ....................................... 4/8
CC-E I/I ....................................... 4/8
CC-E I/I ....................................... 4/8
CC-E I/I ....................................... 4/8
CC-E I/I ....................................... 4/8
CC-E I/I ....................................... 4/8
CC-E I/I ....................................... 4/8
CC-E I/I ....................................... 4/8
CC-E I/I-1 ................................... 4/8
CC-E I/I-2 ................................... 4/8
CC-E I/V ..................................... 4/8
CC-E I/V ..................................... 4/8
CC-E IAC/I ................................ 4/11
CC-E IAC/I ................................ 4/11
CC-E IAC/I ................................ 4/11
CC-E IAC/I ................................ 4/11
CC-E IAC/ILPO .......................... 4/11
CC-E IAC/V ............................... 4/11
CC-E IAC/V ............................... 4/11
CC-E IDC/I ................................ 4/11
CC-E IDC/I ................................ 4/11
CC-E IDC/I ................................ 4/11
CC-E IDC/I ................................ 4/11
CC-E IDC/V ............................... 4/11
CC-E IDC/V ............................... 4/11
CC-E RTD/I ................................. 4/9
CC-E RTD/I ................................. 4/9
CC-E RTD/I ................................. 4/9
CC-E RTD/I ................................. 4/9
CC-E RTD/I ................................. 4/9
CC-E RTD/I ................................. 4/9
CC-E RTD/I ................................. 4/9
CC-E RTD/I ................................. 4/9
CC-E RTD/I ................................. 4/9
CC-E RTD/I ................................. 4/9
CC-E RTD/I ................................. 4/9
CC-E RTD/I ................................. 4/9
CC-E RTD/I ................................. 4/9
CC-E RTD/I ................................. 4/9
CC-E RTD/I ................................. 4/9
CC-E RTD/I ................................. 4/9
CC-E RTD/V ................................ 4/9
CC-E RTD/V ................................ 4/9
CC-E RTD/V ................................ 4/9
CC-E RTD/V ................................ 4/9
CC-E RTD/V ................................ 4/9
CC-E RTD/V ................................ 4/9
CC-E RTD/V ................................ 4/9
CC-E RTD/V ................................ 4/9
CC-E TC/I ................................. 4/10
CC-E TC/I ................................. 4/10
CC-E TC/I ................................. 4/10
CC-E TC/I ................................. 4/10
CC-E TC/I ................................. 4/10
CC-E TC/I ................................. 4/10
CC-E TC/I ................................. 4/10
CC-E TC/I ................................. 4/10
CC-E TC/V ................................ 4/10
CC-E TC/V ................................ 4/10
CC-E TC/V ................................ 4/10
CC-E TC/V ................................ 4/10
CC-E V/I ..................................... 4/8
CC-E V/I ..................................... 4/8
CC-E V/I ..................................... 4/8
CC-E V/I ..................................... 4/8
CC-E V/V .................................... 4/8
CC-E V/V .................................... 4/8
CC-E V/V .................................... 4/8
CC-E V/V .................................... 4/8
CC-E V/V .................................... 4/8
CC-E V/V .................................... 4/8
CC-E/I ...................................... 4/11
CC-E/I ...................................... 4/11
CC-E/RTD ................................... 4/9
CC-E/RTD ................................... 4/9
CC-E/STD ................................... 4/8
CC-E/STD ................................... 4/8
CC-E/TC ................................... 4/10
CC-E/TC ................................... 4/10
CC-U/I ...................................... 4/21
CC-U/I ...................................... 4/21
CC-U/RTD ................................ 4/21
CC-U/RTD ................................ 4/21
CC-U/RTDR .............................. 4/21
CC-U/RTDR .............................. 4/21
CC-U/STD ................................. 4/21
CC-U/STD ................................. 4/21
CC-U/STDR .............................. 4/21
CC-U/STDR .............................. 4/21
CC-U/TC ................................... 4/21
CC-U/TC ................................... 4/21
CC-U/TCR ................................ 4/21
CC-U/TCR ................................ 4/21
CC-U/V ..................................... 4/21
CC-U/V ..................................... 4/21
CL-LAD.FD001 ............................ 6/9
CL-LAD.FD002 ............................ 6/9
CL-LAD.FD011 ............................ 6/9
CL-LAD.MD004 ........................... 6/9
CL-LAD.TK001 ............................ 6/9
CL-LAD.TK002 ............................ 6/9
CL-LAD.TK003 ............................ 6/9
CL-LAD.TK004 ............................ 6/9
CL-LAD.TK005 ............................ 6/9
CL-LAD.TK006 ............................ 6/9
CL-LAD.TK007 ............................ 6/8
CL-LAD.TK009 ............................ 6/9
CL-LAD.TK011 ............................ 6/9
CL-LAS.FD001 ............................ 6/8
CL-LAS.MD003 ........................... 6/8
CL-LAS.PS002 ............................ 6/8
CL-LAS.TK001 ............................ 6/8
CL-LAS.TK002 ............................ 6/8
CL-LAS.TK011 ............................ 6/8
CL-LDC.LAC2 ............................. 6/9
CL-LDC.LDC2 ............................. 6/9
CL-LDC.LNAC2 ........................... 6/9
CL-LDC.LNDC2 ........................... 6/9
CL-LDC.SAC2 ............................. 6/6
CL-LDC.SDC2 ............................. 6/6
CL-LDD.K ................................... 6/6
CL-LDD.K ................................... 6/9
CL-LDD.XK ................................. 6/6
CL-LDD.XK ................................. 6/9
CL-LDR.16AC2 ........................... 6/9
CL-LDR.16DC2 ........................... 6/9
CL-LDR.17DC2 ........................... 6/9
CL-LDT.16DC2 ............................ 6/9
CL-LDT.17DC2 ............................ 6/9
CL-LEC.CI000 ............................. 6/7
CL-LER.18AC2 ............................ 6/7
CL-LER.18DC2 ........................... 6/7
CL-LER.2O ................................. 6/7
CL-LET.20DC2 ............................ 6/7
CL-LMR.C18AC1......................... 6/7
CL-LMR.C18AC2......................... 6/7
CL-LMR.C18DC1 ........................ 6/7
CL-LMR.C18DC2 ........................ 6/7
CL-LMR.CX18AC1....................... 6/7
CL-LMR.CX18AC2....................... 6/7
CL-LMR.CX18DC1 ...................... 6/7
CL-LMR.CX18DC2 ...................... 6/7
CL-LMT.C20DC2 ......................... 6/7
CL-LMT.CX20DC2 ....................... 6/7
CL-LSR.12AC2............................ 6/6
CL-LSR.12DC2 ........................... 6/6
CL-LSR.C12AC1 ......................... 6/6
CL-LSR.C12AC2 ......................... 6/6
CL-LSR.C12DC1 ......................... 6/6
CL-LSR.C12DC2 ......................... 6/6
CL-LSR.CX12AC1 ....................... 6/6
CL-LSR.CX12AC2 ....................... 6/6
CL-LSR.CX12DC1 ....................... 6/6
CL-LSR.CX12DC2 ....................... 6/6
CL-LST.C12DC2 .......................... 6/6
CL-LST.CX12DC2 ........................ 6/6
CM-AH-3 ................................ 2/116
CM-CT 100/1 .......................... 2/131
CM-CT 100/5 .......................... 2/131
CM-CT 150/1 .......................... 2/131
CM-CT 150/5 .......................... 2/131
CM-CT 200/1 .......................... 2/131
CM-CT 200/5 .......................... 2/131
CM-CT 300/1 .......................... 2/131
CM-CT 300/5 .......................... 2/131
CM-CT 400/1 .......................... 2/131
CM-CT 400/5 .......................... 2/131
CM-CT 50/1 ............................ 2/131
CM-CT 50/5 ............................ 2/131
CM-CT 500/1 .......................... 2/131
CM-CT 500/5 .......................... 2/131
CM-CT 600/1 .......................... 2/131
CM-CT 600/5 .......................... 2/131
CM-CT 75/1 ............................ 2/131
CM-CT 75/5 ............................ 2/131
CM-CT A ................................. 2/131
CM-EFS.2P ............................... 2/16
CM-EFS.2S ............................... 2/16
CM-ENE MAX .......................... 2/115
CM-ENE MAX .......................... 2/115
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/2
7
Index
Alphanumerical
Type Page Type Page Type Page Type Page
CM-ENE MAX .......................... 2/115
CM-ENE MIN ........................... 2/115
CM-ENE MIN ........................... 2/115
CM-ENE MIN ........................... 2/115
CM-ENN ................................. 2/115
CM-ENN ................................. 2/115
CM-ENN ................................. 2/115
CM-ENN ................................. 2/115
CM-ENS.................................. 2/115
CM-ENS.................................. 2/115
CM-ENS.................................. 2/115
CM-ENS.................................. 2/115
CM-ENS UP/DOWN ................. 2/115
CM-ENS UP/DOWN ................. 2/115
CM-ENS UP/DOWN ................. 2/115
CM-ESS.1P ............................... 2/16
CM-ESS.1P ............................... 2/16
CM-ESS.1P ............................... 2/16
CM-ESS.1S ............................... 2/16
CM-ESS.1S ............................... 2/16
CM-ESS.1S ............................... 2/16
CM-ESS.2P ............................... 2/16
CM-ESS.2P ............................... 2/16
CM-ESS.2P ............................... 2/16
CM-ESS.2S ............................... 2/16
CM-ESS.2S ............................... 2/16
CM-ESS.2S ............................... 2/16
CM-ESS.MP .............................. 2/16
CM-ESS.MS .............................. 2/16
CM-GM-1 ................................ 2/116
CM-HE .................................... 2/116
CM-IVN.P .................................. 2/66
CM-IVN.S .................................. 2/66
CM-IWN.1P ............................... 2/66
CM-IWN.1S ............................... 2/66
CM-IWN.4P ............................... 2/66
CM-IWN.4S ............................... 2/66
CM-IWN.5P ............................... 2/66
CM-IWN.5S ............................... 2/66
CM-IWN.6P ............................... 2/66
CM-IWN.6S ............................... 2/66
CM-IWS.1P ............................... 2/66
CM-IWS.1S ............................... 2/66
CM-IWS.2P ............................... 2/66
CM-IWS.2S ............................... 2/66
CM-KH-3 ................................ 2/116
CM-LWN ................................... 2/76
CM-LWN ................................... 2/76
CM-LWN ................................... 2/76
CM-LWN ................................... 2/76
CM-LWN ................................... 2/76
CM-LWN ................................... 2/76
CM-LWN ................................... 2/76
CM-LWN ................................... 2/76
CM-LWN ................................... 2/76
CM-LWN ................................... 2/76
CM-MPN.52P ............................ 2/34
CM-MPN.52S ............................ 2/34
CM-MPN.62P ............................ 2/34
CM-MPN.62S ............................ 2/34
CM-MPN.72P ............................ 2/34
CM-MPN.72S ............................ 2/34
CM-MPS.11P ............................ 2/34
CM-MPS.11S ............................ 2/34
CM-MPS.21P ............................ 2/34
CM-MPS.21S ............................ 2/34
CM-MPS.23P ............................ 2/34
CM-MPS.23S ............................ 2/34
CM-MPS.31P ............................ 2/34
CM-MPS.31S ............................ 2/34
CM-MPS.41P ............................ 2/34
CM-MPS.41S ............................ 2/34
CM-MPS.43P ............................ 2/34
CM-MPS.43S ............................ 2/34
CM-MSE ................................... 2/90
CM-MSE ................................... 2/90
CM-MSE ................................... 2/90
CM-MSS.11P ............................ 2/90
CM-MSS.11S ............................ 2/90
CM-MSS.12P ............................ 2/90
CM-MSS.12S ............................ 2/90
CM-MSS.13P ............................ 2/90
CM-MSS.13S ............................ 2/90
CM-MSS.21P ............................ 2/90
CM-MSS.21S ............................ 2/90
CM-MSS.22P ............................ 2/90
CM-MSS.22S ............................ 2/90
CM-MSS.23P ............................ 2/90
CM-MSS.23S ............................ 2/90
CM-MSS.31P ............................ 2/90
CM-MSS.31S ............................ 2/90
CM-MSS.32P ............................ 2/90
CM-MSS.32S ............................ 2/90
CM-MSS.33P ............................ 2/90
CM-MSS.33S ............................ 2/90
CM-MSS.41P ............................ 2/90
CM-MSS.41S ............................ 2/90
CM-MSS.51P ............................ 2/90
CM-MSS.51S ............................ 2/90
CM-PAS.31P ............................. 2/33
CM-PAS.31S ............................. 2/33
CM-PAS.41P ............................. 2/33
CM-PAS.41S ............................. 2/33
CM-PBE .................................... 2/33
CM-PBE .................................... 2/33
CM-PFE .................................... 2/33
CM-PFS.P ................................. 2/33
CM-PFS.S ................................ 2/33
CM-PSS.31P ............................. 2/33
CM-PSS.31S ............................. 2/33
CM-PSS.41P ............................. 2/33
CM-PSS.41S ............................. 2/33
CM-PVE .................................... 2/33
CM-PVE .................................... 2/33
CM-PVS.31P ............................. 2/33
CM-PVS.31S ............................. 2/33
CM-PVS.41P ............................. 2/33
CM-PVS.41S ............................. 2/33
CM-PVS.81P ............................. 2/33
CM-PVS.81S ............................. 2/33
CM-SE-1000 ........................... 2/116
CM-SE-300 ............................. 2/116
CM-SE-600 ............................. 2/116
CM-SFS.21P ............................. 2/15
CM-SFS.21S ............................. 2/15
CM-SFS.22S ............................. 2/15
CM-SRS.11P ............................. 2/15
CM-SRS.11P ............................. 2/15
CM-SRS.11P ............................. 2/15
CM-SRS.11S ............................. 2/15
CM-SRS.11S ............................. 2/15
CM-SRS.11S ............................. 2/15
CM-SRS.12S ............................. 2/15
CM-SRS.12S ............................. 2/15
CM-SRS.12S ............................. 2/15
CM-SRS.21P ............................. 2/15
CM-SRS.21P ............................. 2/15
CM-SRS.21P ............................. 2/15
CM-SRS.21S ............................. 2/15
CM-SRS.21S ............................. 2/15
CM-SRS.21S ............................. 2/15
CM-SRS.22S ............................. 2/15
CM-SRS.22S ............................. 2/15
CM-SRS.22S ............................. 2/15
CM-SRS.M1P ............................ 2/15
CM-SRS.M1S ............................ 2/15
CM-SRS.M2S ............................ 2/15
CM-TCS.11P .......................... 2/104
CM-TCS.11S .......................... 2/104
CM-TCS.12P .......................... 2/104
CM-TCS.12S .......................... 2/104
CM-TCS.13P .......................... 2/104
CM-TCS.13S .......................... 2/104
CM-TCS.21P .......................... 2/104
CM-TCS.21S .......................... 2/104
CM-TCS.22P .......................... 2/104
CM-TCS.22S .......................... 2/104
CM-TCS.23P .......................... 2/104
CM-TCS.23S .......................... 2/104
CM-UFD.M22 ............................ 2/54
CM-UFD.M31 ............................ 2/54
CM-UFD.M33 ............................ 2/54
COV.01 ..................................... 1/40
COV.01 ................................... 2/130
COV.01 ..................................... 4/22
COV.02 ................................... 2/130
COV.11 ..................................... 1/40
COV.11 ................................... 2/130
COV.12 ................................... 2/130
CP-A CM .................................. 3/51
CP-A RU ................................... 3/51
CP-ASI/2.8 ................................ 3/60
CP-ASI/4.0 ................................ 3/60
CP-ASI/4.0 DC/DC .................... 3/60
CP-ASI/8.0 ................................ 3/60
CP-B 24/10.0 ............................ 3/68
CP-B 24/20.0 ............................ 3/68
CP-B 24/3.0 .............................. 3/68
CP-B EXT.2 ............................... 3/68
CP-C 24/10.0 ............................ 3/45
CP-C 24/20.0 ............................ 3/45
CP-C 24/5.0 .............................. 3/45
CP-C MM .................................. 3/45
CP-D 12/0.83 ............................ 3/10
CP-D 12/2.1 .............................. 3/10
CP-D 24/0.42 ............................ 3/10
CP-D 24/0.42 .............................. 6/8
CP-D 24/1.3 .............................. 3/10
CP-D 24/1.3 ................................ 6/8
CP-D 24/2.5 .............................. 3/10
CP-D 24/4.2 .............................. 3/10
CP-D RU ................................... 3/51
CP-E 12/10.0 ............................ 3/20
CP-E 12/2.5 .............................. 3/20
CP-E 24/0.75 ............................ 3/20
CP-E 24/1.25 ............................ 3/20
CP-E 24/10.0 ............................ 3/20
CP-E 24/2.5 .............................. 3/20
CP-E 24/20.0 ............................ 3/20
CP-E 24/5.0 .............................. 3/20
CP-E 48/0.62 ............................ 3/20
CP-E 48/1.25 ............................ 3/20
CP-E 48/10.0 ............................ 3/20
CP-E 48/5.0 .............................. 3/20
2/3 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
7
Index
Alphanumerical
Type Page Type Page Type Page Type Page
CP-E 5/3.0 ................................ 3/20
CP-RUD .................................... 3/51
CP-S 24/10.0 ............................ 3/45
CP-S 24/20.0 ............................ 3/45
CP-S 24/5.0 .............................. 3/45
CP-T 24/10.0 ............................ 3/34
CP-T 24/20.0 ............................ 3/34
CP-T 24/40.0 ............................ 3/34
CP-T 24/5.0 .............................. 3/34
CP-T 48/10.0 ............................ 3/34
CP-T 48/20.0 ............................ 3/34
CP-T 48/5.0 .............................. 3/34
CR-M012DC2 ........................... 5/10
CR-M012DC2L .......................... 5/11
CR-M012DC3 ........................... 5/10
CR-M012DC3L .......................... 5/11
CR-M012DC4 ........................... 5/10
CR-M012DC4L .......................... 5/11
CR-M012DC4LDG ..................... 5/11
CR-M012DC4LG ....................... 5/11
CR-M024AC2 ............................ 5/10
CR-M024AC2L .......................... 5/11
CR-M024AC3 ............................ 5/10
CR-M024AC3L .......................... 5/11
CR-M024AC4 ............................ 5/10
CR-M024AC4G ......................... 5/11
CR-M024AC4L .......................... 5/11
CR-M024AC4LG ....................... 5/11
CR-M024DC2 ........................... 5/10
CR-M024DC2L .......................... 5/11
CR-M024DC3 ........................... 5/10
CR-M024DC3L .......................... 5/11
CR-M024DC4 ........................... 5/10
CR-M024DC4G ......................... 5/11
CR-M024DC4L .......................... 5/11
CR-M024DC4LD ....................... 5/11
CR-M024DC4LDG ..................... 5/11
CR-M024DC4LG ....................... 5/11
CR-M048AC2 ............................ 5/10
CR-M048AC2L .......................... 5/11
CR-M048AC3 ............................ 5/10
CR-M048AC3L .......................... 5/11
CR-M048AC4 ............................ 5/10
CR-M048AC4L .......................... 5/11
CR-M048AC4LG ....................... 5/11
CR-M048DC2 ........................... 5/10
CR-M048DC2L .......................... 5/11
CR-M048DC3 ........................... 5/10
CR-M048DC3L .......................... 5/11
CR-M048DC4 ........................... 5/10
CR-M048DC4L .......................... 5/11
CR-M048DC4LG ....................... 5/11
CR-M060AC3 ............................ 5/10
CR-M060DC2 ........................... 5/10
CR-M060DC2L .......................... 5/11
CR-M060DC3 ........................... 5/10
CR-M060DC3L .......................... 5/11
CR-M060DC4 ........................... 5/10
CR-M060DC4L .......................... 5/11
CR-M060DC4LG ....................... 5/11
CR-M110AC2 ............................ 5/10
CR-M110AC2L .......................... 5/11
CR-M110AC3 ............................ 5/10
CR-M110AC3L .......................... 5/11
CR-M110AC4 ............................ 5/10
CR-M110AC4G ......................... 5/11
CR-M110AC4L .......................... 5/11
CR-M110AC4LG ....................... 5/11
CR-M110DC2 ........................... 5/10
CR-M110DC2L .......................... 5/11
CR-M110DC3 ........................... 5/10
CR-M110DC3L .......................... 5/11
CR-M110DC4 ........................... 5/10
CR-M110DC4L .......................... 5/11
CR-M110DC4LG ....................... 5/11
CR-M120AC2 ............................ 5/10
CR-M120AC2L .......................... 5/11
CR-M120AC3 ............................ 5/10
CR-M120AC3L .......................... 5/11
CR-M120AC4 ............................ 5/10
CR-M120AC4L .......................... 5/11
CR-M120AC4LG ....................... 5/11
CR-M125DC2 ........................... 5/10
CR-M125DC2L .......................... 5/11
CR-M125DC3 ........................... 5/10
CR-M125DC3L .......................... 5/11
CR-M125DC4 ........................... 5/10
CR-M125DC4L .......................... 5/11
CR-M125DC4LG ....................... 5/11
CR-M220DC2 ........................... 5/10
CR-M220DC2L .......................... 5/11
CR-M220DC3 ........................... 5/10
CR-M220DC3L .......................... 5/11
CR-M220DC4 ........................... 5/10
CR-M220DC4L .......................... 5/11
CR-M220DC4LG ....................... 5/11
CR-M230AC2 ............................ 5/10
CR-M230AC2L .......................... 5/11
CR-M230AC3 ............................ 5/10
CR-M230AC3L .......................... 5/11
CR-M230AC4 ............................ 5/10
CR-M230AC4G ......................... 5/11
CR-M230AC4L .......................... 5/11
CR-M230AC4LG ....................... 5/11
CR-M2LC .................................. 5/11
CR-M2LS .................................. 5/11
CR-M2SF .................................. 5/11
CR-M2SS .................................. 5/11
CR-M3LS .................................. 5/11
CR-M3SS .................................. 5/11
CR-M4LC .................................. 5/11
CR-M4LS .................................. 5/11
CR-M4SF .................................. 5/11
CR-M4SS .................................. 5/11
CR-MH ..................................... 5/11
CR-MH1.................................... 5/11
CR-MJ ...................................... 5/11
CR-MM ..................................... 5/11
CR-P/M 22 ................................ 5/12
CR-P/M 42 ................................ 5/12
CR-P/M 42B ............................. 5/12
CR-P/M 42BV ........................... 5/12
CR-P/M 42C ............................. 5/12
CR-P/M 42CV ........................... 5/12
CR-P/M 42V .............................. 5/12
CR-P/M 52B ............................. 5/12
CR-P/M 52C ............................. 5/12
CR-P/M 52D ............................. 5/12
CR-P/M 62 ................................ 5/12
CR-P/M 62C ............................. 5/12
CR-P/M 62CV ........................... 5/12
CR-P/M 62D ............................. 5/12
CR-P/M 62DV ........................... 5/12
CR-P/M 62E .............................. 5/12
CR-P/M 62EV ............................ 5/12
CR-P/M 62V .............................. 5/12
CR-P/M 72 ................................ 5/12
CR-P/M 72A.............................. 5/12
CR-P/M 82 ................................ 5/12
CR-P/M 92 ................................ 5/12
CR-P/M 92C ............................. 5/12
CR-P/M 92CV ........................... 5/12
CR-P/M 92V .............................. 5/12
CR-P012DC1 .............................. 5/9
CR-P012DC2 .............................. 5/9
CR-P024AC1 .............................. 5/9
CR-P024AC2 .............................. 5/9
CR-P024AC2G ............................ 5/9
CR-P024DC1 .............................. 5/9
CR-P024DC2 .............................. 5/9
CR-P024DC2 .............................. 5/9
CR-P048AC1 .............................. 5/9
CR-P048AC2 .............................. 5/9
CR-P048DC1 .............................. 5/9
CR-P048DC2 .............................. 5/9
CR-P110AC1 .............................. 5/9
CR-P110AC2 .............................. 5/9
CR-P110AC2G ............................ 5/9
CR-P110DC1 .............................. 5/9
CR-P110DC2 .............................. 5/9
CR-P120AC1 .............................. 5/9
CR-P120AC2 .............................. 5/9
CR-P230AC1 .............................. 5/9
CR-P230AC2 .............................. 5/9
CR-P230AC2G ............................ 5/9
CR-PH ........................................ 5/9
CR-PJ ......................................... 5/9
CR-PLC ...................................... 5/9
CR-PLS ...................................... 5/9
CR-PLSx ..................................... 5/9
CR-PM ........................................ 5/9
CR-PSS ...................................... 5/9
CR-S005VDC1R .......................... 5/8
CR-S005VDC1RG ....................... 5/8
CR-S006/024VDC1SS ................. 5/8
CR-S006/024VDC1SZ ................. 5/8
CR-S012/024VADC1SS ............... 5/8
CR-S012/024VADC1SZ ............... 5/8
CR-S012VDC1R .......................... 5/8
CR-S012VDC1RG ....................... 5/8
CR-S024VADC1CRGS ................. 5/8
CR-S024VADC1CRGZ ................. 5/8
CR-S024VADC1CRS ................... 5/8
CR-S024VADC1CRZ .................... 5/8
CR-S024VDC1R .......................... 5/8
CR-S024VDC1RG ....................... 5/8
CR-S048/060VADC1SS ............... 5/8
CR-S048/060VADC1SZ ............... 5/8
CR-S048VDC1R .......................... 5/8
CR-S048VDC1RG ....................... 5/8
CR-S060VDC1R .......................... 5/8
CR-S060VDC1RG ....................... 5/8
CR-S110/125VADC1SS ............... 5/8
CR-S110/125VADC1SZ ............... 5/8
CR-S110VADC1CRGS ................. 5/8
CR-S110VADC1CRGZ ................. 5/8
CR-S110VADC1CRS ................... 5/8
CR-S110VADC1CRZ .................... 5/8
CR-S220/240VADC1SS ............... 5/8
CR-S220/240VADC1SZ ............... 5/8
CR-S230VADC1CRGS ................. 5/8
CR-S230VADC1CRGZ ................. 5/8
CR-S230VADC1CRS ................... 5/8
CR-S230VADC1CRZ .................... 5/8
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/4
7
Index
Alphanumerical
Type Page Type Page Type Page Type Page
CR-SJB20-BLACK....................... 5/8
CR-SJB20-BLUE ......................... 5/8
CR-SJB20-RED ........................... 5/8
CR-SM ........................................ 5/8
CR-SSEP .................................... 5/8
CR-U 21 ................................... 5/14
CR-U 41 ................................... 5/14
CR-U 41B ................................. 5/14
CR-U 41BV ............................... 5/14
CR-U 41C ................................. 5/14
CR-U 41CV ............................... 5/14
CR-U 41V ................................. 5/14
CR-U 51B ................................. 5/14
CR-U 51C ................................. 5/14
CR-U 51D ................................. 5/14
CR-U 61 ................................... 5/14
CR-U 61C ................................. 5/14
CR-U 61CV ............................... 5/14
CR-U 61D ................................. 5/14
CR-U 61DV ............................... 5/14
CR-U 61E ................................. 5/14
CR-U 61EV ............................... 5/14
CR-U 61V ................................. 5/14
CR-U 71 ................................... 5/14
CR-U 71A ................................. 5/14
CR-U 81 ................................... 5/14
CR-U 91 ................................... 5/14
CR-U 91C ................................. 5/14
CR-U 91CV ............................... 5/14
CR-U 91V ................................. 5/14
CR-U T ..................................... 5/14
CR-U012DC2 ............................ 5/13
CR-U012DC2L .......................... 5/13
CR-U012DC3 ............................ 5/13
CR-U012DC3L .......................... 5/13
CR-U024AC2 ............................ 5/13
CR-U024AC2L .......................... 5/13
CR-U024AC3 ............................ 5/13
CR-U024AC3L .......................... 5/13
CR-U024DC2 ............................ 5/13
CR-U024DC2L .......................... 5/13
CR-U024DC3 ............................ 5/13
CR-U024DC3L .......................... 5/13
CR-U048AC2 ............................ 5/13
CR-U048AC2L .......................... 5/13
CR-U048AC3 ............................ 5/13
CR-U048AC3L .......................... 5/13
CR-U048DC2 ............................ 5/13
CR-U048DC2L .......................... 5/13
CR-U048DC3 ............................ 5/13
CR-U048DC3L .......................... 5/13
CR-U060AC3 ............................ 5/13
CR-U110AC2 ............................ 5/13
CR-U110AC2L .......................... 5/13
CR-U110AC3 ............................ 5/13
CR-U110AC3L .......................... 5/13
CR-U110DC2 ............................ 5/13
CR-U110DC2L .......................... 5/13
CR-U110DC3 ............................ 5/13
CR-U110DC3L .......................... 5/13
CR-U120AC2 ............................ 5/13
CR-U120AC2L .......................... 5/13
CR-U120AC3 ............................ 5/13
CR-U120AC3L .......................... 5/13
CR-U125DC3 ............................ 5/13
CR-U220DC2 ............................ 5/13
CR-U220DC2L .......................... 5/13
CR-U220DC3 ............................ 5/13
CR-U220DC3L .......................... 5/13
CR-U230AC2 ............................ 5/13
CR-U230AC2L .......................... 5/13
CR-U230AC3 ............................ 5/13
CR-U230AC3L .......................... 5/13
CR-U2S .................................... 5/13
CR-U2SM ................................. 5/13
CR-U3E .................................... 5/13
CR-U3S .................................... 5/13
CR-U3SM ................................. 5/13
CR-UH ...................................... 5/13
CT- MXS.22S............................. 1/37
CT-AHD.12 .................................. 1/8
CT-AHD.22 .................................. 1/8
CT-AHE ..................................... 1/20
CT-AHE ..................................... 1/20
CT-AHE ..................................... 1/20
CT-AHE ..................................... 1/20
CT-AHE ..................................... 1/20
CT-AHE ..................................... 1/20
CT-AHE ..................................... 1/20
CT-AHE ..................................... 1/20
CT-AHE ..................................... 1/20
CT-AHS.22P .............................. 1/38
CT-AHS.22S .............................. 1/38
CT-AKE ..................................... 1/21
CT-AKE ..................................... 1/21
CT-AKE ..................................... 1/21
CT-APS.12P .............................. 1/38
CT-APS.12S .............................. 1/38
CT-APS.21P .............................. 1/38
CT-APS.21S .............................. 1/38
CT-APS.22P .............................. 1/38
CT-APS.22S .............................. 1/38
CT-ARE ..................................... 1/20
CT-ARE ..................................... 1/20
CT-ARE ..................................... 1/20
CT-ARE ..................................... 1/20
CT-ARS.11P .............................. 1/38
CT-ARS.11S .............................. 1/38
CT-ARS.21P .............................. 1/38
CT-ARS.21S .............................. 1/38
CT-AWE .................................... 1/20
CT-AWE .................................... 1/20
CT-AWE .................................... 1/20
CT-AWE ................................... 1/21
CT-AWE ................................... 1/21
CT-AWE ................................... 1/21
CT-AWE ................................... 1/21
CT-AWE ................................... 1/21
CT-AWE ................................... 1/21
CT-AWE ................................... 1/21
CT-AWE ................................... 1/21
CT-AWE ................................... 1/21
CT-EBD.12 .................................. 1/8
CT-EBE ..................................... 1/21
CT-EBE ..................................... 1/21
CT-EKE ..................................... 1/21
CT-EKE ..................................... 1/21
CT-EKE ..................................... 1/21
CT-ERD.12 .................................. 1/8
CT-ERD.22 .................................. 1/8
CT-ERE ..................................... 1/20
CT-ERE ..................................... 1/20
CT-ERE ..................................... 1/20
CT-ERE ..................................... 1/20
CT-ERE ..................................... 1/20
CT-ERE ..................................... 1/20
CT-ERE ..................................... 1/20
CT-ERE ..................................... 1/20
CT-ERS.12P .............................. 1/38
CT-ERS.12S .............................. 1/38
CT-ERS.21P .............................. 1/38
CT-ERS.21S .............................. 1/38
CT-ERS.22P .............................. 1/38
CT-ERS.22S .............................. 1/38
CT-MBS.22P ............................. 1/37
CT-MBS.22S ............................. 1/37
CT-MFD.12 .................................. 1/8
CT-MFD.21 .................................. 1/8
CT-MFE ..................................... 1/20
CT-MFS.21 ................................ 1/37
CT-MFS.21P .............................. 1/37
CT-MKE .................................... 1/21
CT-MVS.12P ............................. 1/37
CT-MVS.12S ............................. 1/37
CT-MVS.21P ............................. 1/37
CT-MVS.21S ............................. 1/37
CT-MVS.22P ............................. 1/37
CT-MVS.22S ............................. 1/37
CT-MVS.23P ............................. 1/37
CT-MVS.23S ............................. 1/37
CT-MXS.22P.............................. 1/37
CT-SAD.22 .................................. 1/8
CT-SDD.22 .................................. 1/8
CT-SDE ..................................... 1/21
CT-SDE ..................................... 1/21
CT-SDE ..................................... 1/21
CT-SDS.22P .............................. 1/38
CT-SDS.22S .............................. 1/38
CT-SDS.23P .............................. 1/38
CT-SDS.23S .............................. 1/38
CT-TGD.12 .................................. 1/8
CT-TGD.22 .................................. 1/8
CT-VWD.12 ................................. 1/8
CT-VWE .................................... 1/20
CT-VWE .................................... 1/20
CT-VWE .................................... 1/20
CT-VWE .................................... 1/20
CT-VWE .................................... 1/20
CT-VWE .................................... 1/20
CT-WBS.22P ............................. 1/37
CT-WBS.22S ............................. 1/37
CT-YDE ..................................... 1/21
CT-YDE ..................................... 1/21
CT-YDE ..................................... 1/21
CT-YDE ..................................... 1/21
CT-YDE ..................................... 1/21
CT-YDE ..................................... 1/21
E
EPD24-TB-101-0.5A.................. 3/75
EPD24-TB-101-10A................... 3/75
EPD24-TB-101-12A................... 3/75
EPD24-TB-101-1A .................... 3/75
EPD24-TB-101-2A .................... 3/75
EPD24-TB-101-3A .................... 3/75
EPD24-TB-101-4A .................... 3/75
EPD24-TB-101-6A .................... 3/75
EPD24-TB-101-8A .................... 3/75
EPD-BB500............................... 3/75
EPD-SB21 ................................. 3/75
F
FC2 .......................................... 5/47
2/5 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
7
Index
Alphanumerical
OBOC 1000-48-60VAC/DC ........ 5/47
OBOC 1000-5-12VDC ............... 5/47
OBOC 1500-24VAC/DC ............. 5/47
OBOC 5000-115VAC/DC ........... 5/47
OBOC 5000-230VAC/DC ........... 5/47
OBOC 5000-24VDC .................. 5/47
OBRIC 0100-115-230VAC/DC ... 5/47
OBRIC 0100-24VDC .................. 5/47
OBRIC 0100-48-60VAC/DC ....... 5/47
OBRIC 0100-5-12VDC ............... 5/47
OBROA 1000-115VAC/DC ......... 5/47
OBROA 1000-230VAC/DC ......... 5/47
OBROA 1000-24VDC ................ 5/47
OBROA 1000-48-60VAC/DC ...... 5/47
OBROA 2000-24VDC ................ 5/47
OBROC 1000-115VAC/DC ......... 5/47
OBROC 1000-230VAC/DC ......... 5/47
OBROC 1000-24VDC ................ 5/47
OBROC 1000-48-60VAC/DC ...... 5/47
OBROC 1000-5-12VDC ............. 5/47
OBROC 1500-24VAC/DC ........... 5/47
OBROC 5000-115VAC/DC ......... 5/47
OBROC 5000-230VAC/DC ......... 5/47
OBROC 5000-24VDC ................ 5/47
R
RB101AR-24VAC/DC ................. 5/35
RB111A-115VAC/DC ................. 5/35
RB111A-230VAC/DC ................. 5/35
RB111A-24VAC/DC ................... 5/35
RB111AR-24VAC/DC ................. 5/35
RB121-12VDC .......................... 5/36
RB121-12VDC .......................... 5/36
RB121-24VDC .......................... 5/36
RB121-5VDC ............................ 5/36
RB121-5VDC ............................ 5/35
RB121A-115VAC/DC ................. 5/36
RB121A-115VAC/DC ................. 5/35
RB121A-230VAC/DC ................. 5/36
RB121A-230VAC/DC ................. 5/35
RB121A-24VAC/DC ................... 5/36
RB121A-24VAC/DC ................... 5/35
RB121A-48-60VAC/DC .............. 5/36
RB121A-48-60VAC/DC .............. 5/35
RB121A-60-230VUC ................. 5/36
RB121AR-115VAC/DC ............... 5/36
RB121AR-230VAC/DC ............... 5/36
RB121-AU-12VDC ..................... 5/35
RB121-AU-24VDC ..................... 5/35
RB122A-115VAC/DC ................. 5/36
RB122A-230VAC/DC ................. 5/36
Type Page Type PageType Page
I
ILPH BdC /RS 422 - 485 (24 V DC
power supply) ............................ 4/37
ILPH RS 232 (24 V DC power supply)
4/37
ILPH RS 232 / FO-S (24...42 V AC/
DC power supply) ...................... 4/37
ILPH RS 232 / RS 232 (115-230 V AC
power supply) ............................ 4/37
ILPH RS 232 / RS 232 (24-48 V DC
power supply) ............................ 4/37
ILPH RS 232 / RS 422-485 ........ 4/37
ILPH RS 232 / RS 422-485 ........ 4/37
ILPH RS 232 / RS 422-485 (115-230
V AC power supply) ................... 4/37
ILPH RS 232 / RS 422-485 (24-48 V
DC power supply) ...................... 4/37
ILPH RS 232-RS 485 / Ethernet . 4/37
ILPH RS 422 - 485 / RS 422 - 485
(24 V DC power supply) ............. 4/37
ILPH RS 485 / FO-S (24...42 V AC/
DC power supply) ...................... 4/37
K
KA1-8029 ................................. 1/39
KA1-8030 ................................. 1/39
M
MA16-1060 ............................... 1/39
MAR.01..................................... 1/40
MAR.01..................................... 1/40
MAR.01................................... 2/130
MAR.01..................................... 4/22
MAR.02..................................... 1/40
MAR.02................................... 2/130
MAR.12..................................... 1/40
MAR.12................................... 2/130
MT-150B ................................... 1/39
MT-250B ................................... 1/39
MT-350B ................................... 1/39
O
OBIC 0100-115-230VAC/DC ...... 5/47
OBIC 0100-24VDC .................... 5/47
OBIC 0100-48-60VAC/DC.......... 5/47
OBIC 0100-5-12VDC ................. 5/47
OBOA 1000-115VAC/DC ........... 5/47
OBOA 1000-230VAC/DC ........... 5/47
OBOA 1000-24VDC ................... 5/47
OBOA 1000-48-60VAC/DC ........ 5/47
OBOA 2000-24VDC ................... 5/47
OBOC 1000-115VAC/DC ........... 5/47
OBOC 1000-230VAC/DC ........... 5/47
OBOC 1000-24VDC .................. 5/47
RB122A-24VAC/DC ................... 5/36
RB122A-48-60VAC/DC .............. 5/36
RBR101AR-24VAC/DC .............. 5/35
RBR111A-24VAC/DC ................. 5/35
RBR111AR-24VAC/DC .............. 5/35
RBR121-12VDC ........................ 5/36
RBR121-12VDC ........................ 5/36
RBR121-24VDC ........................ 5/36
RBR121-5VDC .......................... 5/36
RBR121-5VDC .......................... 5/35
RBR121A-115VAC/DC ............... 5/36
RBR121A-115VAC/DC ............... 5/35
RBR121A-230VAC/DC ............... 5/36
RBR121A-230VAC/DC ............... 5/35
RBR121A-24VAC/DC ................. 5/36
RBR121A-24VAC/DC ................. 5/35
RBR121A-48-60VUC ................. 5/36
RBR121A-48-60VUC ................. 5/35
RBR121A-60-230VUC ............... 5/36
RBR121AR-115VAC/DC ............ 5/36
RBR121AR-230VAC/DC ............ 5/36
RBR121-AU-12VDC .................. 5/35
RBR121-AU-24VDC .................. 5/35
RBR122A-115VAC/DC ............... 5/36
RBR122A-230VAC/DC ............... 5/36
RBR122A-24VAC/DC ................. 5/36
RBR122A-48-60VUC ................. 5/36
S
SC 612 ..................................... 5/36
SC 612 ..................................... 5/47
SK 615 562-87 .......................... 1/39
SK 615 562-88 .......................... 1/39
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/6
7
Index
Numerical
1SAR
1SAR700100R0005 .. C512-24 ................................... 2/104
1SAR700100R0010 .. C512-W .................................... 2/104
1SAR700110R0010 .. C513-W .................................... 2/104
1SFA
1SFA611410R1506 .. MT-150B..................................... 1/39
1SFA611410R2506 .. MT-250B..................................... 1/39
1SFA611410R3506 .. MT-350B..................................... 1/39
1SFA611940R1060 .. MA16-1060 ................................ 1/39
1SFA616920R8029 .. KA1-8029 ................................... 1/39
1SFA616920R8030 .. KA1-8030 ................................... 1/39
1SNA
1SNA116900R2700 .. BADH V0 .................................... 5/47
1SNA206754R0000 .. BJ 612-20 .................................. 5/36
1SNA206754R0000 .. BJ 612-20 .................................. 5/47
1SNA290474R0200 .. SC 612 ....................................... 5/36
1SNA290474R0200 .. SC 612 ....................................... 5/47
1SNA290488R0100 .. BJ 612-10 .................................. 5/36
1SNA290488R0100 .. BJ 612-10 .................................. 5/47
1SNA399903R0200 .. BADL V0 ..................................... 5/47
1SNA399967R0100 .. BAM2 V0 .................................... 5/47
1SNA645001R0300 .. RB121A-24VAC/DC .................... 5/36
1SNA645002R0400 .. RB121A-48-60VAC/DC ............... 5/36
1SNA645003R0500 .. RB121A-115VAC/DC .................. 5/36
1SNA645004R0400 .. RB121A-230VAC/DC .................. 5/36
1SNA645005R0700 .. RB121A-24VAC/DC .................... 5/35
1SNA645006R0000 .. RB121A-48-60VAC/DC ............... 5/35
1SNA645007R0100 .. RB121A-115VAC/DC .................. 5/35
1SNA645008R1200 .. RB121A-230VAC/DC .................. 5/35
1SNA645011R2400 .. RB121AR-230VAC/DC ................ 5/36
1SNA645012R2500 .. RB122A-24VAC/DC .................... 5/36
1SNA645013R2600 .. RB122A-230VAC/DC .................. 5/36
1SNA645014R2700 .. RB111A-24VAC/DC .................... 5/35
1SNA645016R2100 .. RB111A-115VAC/DC .................. 5/35
1SNA645017R2200 .. RB111A-230VAC/DC .................. 5/35
1SNA645018R0300 .. RB111AR-24VAC/DC .................. 5/35
1SNA645019R0400 .. RB101AR-24VAC/DC .................. 5/35
1SNA645020R0100 .. RB121A-60-230VUC ................... 5/36
1SNA645021R2600 .. OBIC 0100-24VDC ...................... 5/47
1SNA645022R2700 .. OBIC 0100-115-230VAC/DC ....... 5/47
1SNA645024R2100 .. OBOC 5000-24VDC .................... 5/47
1SNA645025R2200 .. OBOC 1500-24VAC/DC .............. 5/47
1SNA645026R2300 .. OBOC 1000-230VAC/DC ............. 5/47
1SNA645027R2400 .. OBOA 1000-24VDC .................... 5/47
1SNA645028R0500 .. OBOA 1000-230VAC/DC ............. 5/47
1SNA645029R0600 .. OBOA 2000-24VDC .................... 5/47
1SNA645034R2300 .. RB121-5VDC .............................. 5/36
1SNA645035R2400 .. RB121-12VDC ............................ 5/36
1SNA645036R2500 .. RB121-5VDC .............................. 5/35
1SNA645040R1500 .. RB122A-48-60VAC/DC ............... 5/36
1SNA645041R0200 .. RB122A-115VAC/DC .................. 5/36
1SNA645046R0700 .. RB121AR-115VAC/DC ................ 5/36
1SNA645047R0000 .. OBIC 0100-5-12VDC .................. 5/47
1SNA645049R1200 .. OBIC 0100-48-60VAC/DC ........... 5/47
1SNA645050R1700 .. OBOC 1000-5-12VDC ................. 5/47
1SNA645051R0400 .. OBOC 1000-24VDC .................... 5/47
1SNA645053R0600 .. OBOC 1000-48-60VAC/DC ......... 5/47
1SNA645054R0700 .. OBOC 1000-115VAC/DC ............. 5/47
1SNA645058R1300 .. OBOC 5000-115VAC/DC ............. 5/47
1SNA645059R1400 .. OBOC 5000-230VAC/DC ............. 5/47
1SNA645061R0600 .. OBOA 1000-48-60VAC/DC .......... 5/47
1SNA645062R0700 .. OBOA 1000-115VAC/DC ............. 5/47
1SNA645071R0000 .. RB121-24VDC ............................ 5/36
1SNA645072R0000 .. RB121-AU-24VDC ...................... 5/35
1SNA645073R0000 .. RB121-12VDC ............................ 5/36
1SNA645075R0000 .. RB121-AU-12VDC ...................... 5/35
1SNA645501R0500 .. RBR121A-24VAC/DC .................. 5/36
1SNA645502R0600 .. RBR121A-48-60VUC................... 5/36
1SNA645503R0700 .. RBR121A-115VAC/DC ................ 5/36
1SNA645504R0000 .. RBR121A-230VAC/DC ................ 5/36
1SNA645505R0100 .. RBR121A-24VAC/DC .................. 5/35
1SNA645506R0200 .. RBR121A-48-60VUC................... 5/35
1SNA645507R0300 .. RBR121A-115VAC/DC ................ 5/35
1SNA645508R1400 .. RBR121A-230VAC/DC ................ 5/35
1SNA645511R2600 .. RBR121AR-230VAC/DC .............. 5/36
1SNA645512R2700 .. RBR122A-24VAC/DC .................. 5/36
1SNA645513R2000 .. RBR122A-230VAC/DC ................ 5/36
1SNA645514R2100 .. RBR111A-24VAC/DC .................. 5/35
1SNA645518R0500 .. RBR111AR-24VAC/DC ................ 5/35
1SNA645519R0600 .. RBR101AR-24VAC/DC ................ 5/35
1SNA645520R0300 .. RBR121A-60-230VUC ................. 5/36
1SNA645521R2000 .. OBRIC 0100-24VDC ................... 5/47
1SNA645522R2100 .. OBRIC 0100-115-230VAC/DC ..... 5/47
1SNA645524R2300 .. OBROC 5000-24VDC .................. 5/47
1SNA645525R2400 .. OBROC 1500-24VAC/DC ............ 5/47
1SNA645526R2500 .. OBROC 1000-230VAC/DC .......... 5/47
1SNA645527R2600 .. OBROA 1000-24VDC .................. 5/47
1SNA645528R0700 .. OBROA 1000-230VAC/DC........... 5/47
1SNA645529R0000 .. OBROA 2000-24VDC .................. 5/47
1SNA645531R2200 .. FC2 ............................................ 5/47
1SNA645534R2500 .. RBR121-5VDC ............................ 5/36
1SNA645535R2600 .. RBR121-12VDC .......................... 5/36
1SNA645536R2700 .. RBR121-5VDC ............................ 5/35
1SNA645540R1700 .. RBR122A-48-60VUC................... 5/36
1SNA645541R0400 .. RBR122A-115VAC/DC ................ 5/36
1SNA645546R0100 .. RBR121AR-115VAC/DC .............. 5/36
1SNA645547R0200 .. OBRIC 0100-5-12VDC ................ 5/47
1SNA645549R1400 .. OBRIC 0100-48-60VAC/DC ......... 5/47
1SNA645550R1100 .. OBROC 1000-5-12VDC............... 5/47
1SNA645551R0600 .. OBROC 1000-24VDC .................. 5/47
1SNA645553R0000 .. OBROC 1000-48-60VAC/DC ....... 5/47
1SNA645554R0100 .. OBROC 1000-115VAC/DC .......... 5/47
1SNA645558R1500 .. OBROC 5000-115VAC/DC .......... 5/47
1SNA645559R1600 .. OBROC 5000-230VAC/DC .......... 5/47
1SNA645561R0000 .. OBROA 1000-48-60VAC/DC ....... 5/47
1SNA645562R0100 .. OBROA 1000-115VAC/DC........... 5/47
1SNA645571R0000 .. RBR121-24VDC .......................... 5/36
1SNA645572R0000 .. RBR121-AU-24VDC .................... 5/35
1SNA645573R0000 .. RBR121-12VDC .......................... 5/36
1SNA645575R0000 .. RBR121-AU-12VDC .................... 5/35
1SNA684202R0100 .. ILPH RS 232 (24 V DC power supply)..
4/37
1SNA684212R2200 .. ILPH RS 422 - 485 / RS 422 - 485 (24
V DC power supply) .. 4/37
1SNA684231R2500 .. ILPH RS 232 / RS 422-485 ......... 4/37
1SNA684232R2600 .. ILPH BdC /RS 422 - 485 (24 V DC
power supply) ........... 4/37
1SNA684233R2700 .. ILPH RS 232 / RS 422-485 ......... 4/37
1SNA684234R0200 .. ILPH RS 232 / RS 232 (115-230 V AC
power supply) ........... 4/37
1SNA684234R2000 .. ILPH RS 232 / RS 232 (24-48 V DC
power supply) ........... 4/37
1SNA684236R2200 .. ILPH RS 232 / FO-S (24...42 V AC/DC
power supply) ........... 4/37
1SNA684246R0400 .. ILPH RS 485 / FO-S (24...42 V AC/DC
power supply) ........... 4/37
1SNA684252R0200 .. ILPH RS 232-RS 485 / Ethernet ... 4/37
1SNA684333R2300 .. ILPH RS 232 / RS 422-485 (24-48 V
DC power supply) ..... 4/37
1SNA684334R2400 .. ILPH RS 232 / RS 422-485 (115-230
V AC power supply) .. 4/37
1SNB041391R0610 .. CR-SM ......................................... 5/8
1SVR
1SVR010200R1600 .. CC-E I/I-1 ..................................... 4/8
1SVR010201R0300 .. CC-E I/I-2 ..................................... 4/8
1SVR010203R0500 .. CC-E IAC/ILPO ........................... 4/11
1SVR011700R0000 .. CC-E/STD .................................... 4/8
1SVR011701R2500 .. CC-E/RTD .................................... 4/9
1SVR011702R2600 .. CC-E/TC..................................... 4/10
1SVR011703R2700 .. CC-E/I ........................................ 4/11
1SVR011705R2100 .. CC-E/STD .................................... 4/8
1SVR011706R2200 .. CC-E/RTD .................................... 4/9
1SVR011707R2300 .. CC-E/TC..................................... 4/10
1SVR011708R0400 .. CC-E/I ........................................ 4/11
1SVR011710R2100 .. CC-E V/V ...................................... 4/8
1SVR011711R1600 .. CC-E V/I ....................................... 4/8
1SVR011712R1700 .. CC-E V/I ....................................... 4/8
1SVR011713R1000 .. CC-E I/V ....................................... 4/8
1SVR011714R1100 .. CC-E I/I ........................................ 4/8
1SVR011715R1200 .. CC-E I/I ........................................ 4/8
1SVR011716R1300 .. CC-E I/V ....................................... 4/8
1SVR011717R1400 .. CC-E I/I ........................................ 4/8
1SVR011718R2500 .. CC-E I/I ........................................ 4/8
Order code Type Page Order code Type Page Order code Type Page
2/7 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
7
Index
Numerical
1SVR011719R2600 .. CC-E V/V ...................................... 4/8
1SVR011720R2300 .. CC-E V/V ...................................... 4/8
1SVR011721R1000 .. CC-E V/I ....................................... 4/8
1SVR011722R1100 .. CC-E V/I ....................................... 4/8
1SVR011723R1200 .. CC-E V/V ...................................... 4/8
1SVR011724R1300 .. CC-E I/I ........................................ 4/8
1SVR011725R1400 .. CC-E I/I ........................................ 4/8
1SVR011726R1500 .. CC-E V/V ...................................... 4/8
1SVR011727R1600 .. CC-E I/I ........................................ 4/8
1SVR011728R2700 .. CC-E I/I ........................................ 4/8
1SVR011729R2000 .. CC-E V/V ...................................... 4/8
1SVR011730R2500 .. CC-E RTD/V ................................. 4/9
1SVR011731R1200 .. CC-E RTD/I .................................. 4/9
1SVR011732R1300 .. CC-E RTD/I .................................. 4/9
1SVR011733R1400 .. CC-E RTD/V ................................. 4/9
1SVR011734R1500 .. CC-E RTD/I .................................. 4/9
1SVR011735R1600 .. CC-E RTD/I .................................. 4/9
1SVR011736R1700 .. CC-E RTD/V ................................. 4/9
1SVR011737R1000 .. CC-E RTD/I .................................. 4/9
1SVR011738R2100 .. CC-E RTD/I .................................. 4/9
1SVR011739R2200 .. CC-E RTD/V ................................. 4/9
1SVR011740R0700 .. CC-E RTD/I .................................. 4/9
1SVR011741R2400 .. CC-E RTD/I .................................. 4/9
1SVR011750R0100 .. CC-E TC/V.................................. 4/10
1SVR011751R2600 .. CC-E TC/I ................................... 4/10
1SVR011752R2700 .. CC-E TC/I ................................... 4/10
1SVR011753R2000 .. CC-E TC/V.................................. 4/10
1SVR011754R2100 .. CC-E TC/I ................................... 4/10
1SVR011755R2200 .. CC-E TC/I ................................... 4/10
1SVR011760R0300 .. CC-E TC/V.................................. 4/10
1SVR011761R2000 .. CC-E TC/I ................................... 4/10
1SVR011762R2100 .. CC-E TC/I ................................... 4/10
1SVR011763R2200 .. CC-E TC/V.................................. 4/10
1SVR011764R2300 .. CC-E TC/I ................................... 4/10
1SVR011765R2400 .. CC-E TC/I ................................... 4/10
1SVR011770R0500 .. CC-E IAC/V ................................ 4/11
1SVR011771R2200 .. CC-E IAC/I .................................. 4/11
1SVR011772R2300 .. CC-E IAC/I .................................. 4/11
1SVR011773R2400 .. CC-E IDC/V ................................ 4/11
1SVR011774R2500 .. CC-E IDC/I ................................. 4/11
1SVR011775R2600 .. CC-E IDC/I ................................. 4/11
1SVR011780R1100 .. CC-E IAC/V ................................ 4/11
1SVR011781R0600 .. CC-E IAC/I .................................. 4/11
1SVR011782R0700 .. CC-E IAC/I .................................. 4/11
1SVR011783R0000 .. CC-E IDC/V ................................ 4/11
1SVR011784R0100 .. CC-E IDC/I ................................. 4/11
1SVR011785R1100 .. CC-E IDC/I ................................. 4/11
1SVR011788R2400 .. CC-E RTD/V ................................. 4/9
1SVR011789R2500 .. CC-E RTD/I .................................. 4/9
1SVR011790R2200 .. CC-E RTD/I .................................. 4/9
1SVR011791R1700 .. CC-E RTD/V ................................. 4/9
1SVR011792R1000 .. CC-E RTD/I .................................. 4/9
1SVR011793R1100 .. CC-E RTD/I .................................. 4/9
1SVR011794R1200 .. CC-E RTD/V ................................. 4/9
1SVR011795R1300 .. CC-E RTD/I .................................. 4/9
1SVR011796R1400 .. CC-E RTD/I .................................. 4/9
1SVR011797R1500 .. CC-E RTD/V ................................. 4/9
1SVR011798R2600 .. CC-E RTD/I .................................. 4/9
1SVR011799R2700 .. CC-E RTD/I .................................. 4/9
1SVR040000R1700 .. CC-U/STD .................................. 4/21
1SVR040001R0400 .. CC-U/STD .................................. 4/21
1SVR040002R0500 .. CC-U/RTD .................................. 4/21
1SVR040003R0600 .. CC-U/RTD .................................. 4/21
1SVR040004R0700 .. CC-U/TC .................................... 4/21
1SVR040005R0000 .. CC-U/TC .................................... 4/21
1SVR040006R0100 .. CC-U/I ........................................ 4/21
1SVR040007R0200 .. CC-U/I ........................................ 4/21
1SVR040008R1300 .. CC-U/V ...................................... 4/21
1SVR040009R1400 .. CC-U/V ...................................... 4/21
1SVR040010R0000 .. CC-U/STDR ................................ 4/21
1SVR040011R2500 .. CC-U/STDR ................................ 4/21
1SVR040012R2600 .. CC-U/RTDR ................................ 4/21
1SVR040013R2700 .. CC-U/RTDR ................................ 4/21
1SVR040014R2000 .. CC-U/TCR .................................. 4/21
1SVR040015R2100 .. CC-U/TCR .................................. 4/21
1SVR366017R0100 .. MAR.01 ...................................... 1/40
1SVR366017R0100 .. MAR.01 ...................................... 1/40
1SVR366017R0100 .. MAR.01 .................................... 2/130
1SVR366017R0100 .. MAR.01 ...................................... 4/22
1SVR402902R0000 .. CM-HE ..................................... 2/116
1SVR405501R1010 .. CR-S005VDC1R ........................... 5/8
1SVR405501R1020 .. CR-S005VDC1RG ......................... 5/8
1SVR405501R2010 .. CR-S012VDC1R ........................... 5/8
1SVR405501R2020 .. CR-S012VDC1RG ......................... 5/8
1SVR405501R3010 .. CR-S024VDC1R ........................... 5/8
1SVR405501R3020 .. CR-S024VDC1RG ......................... 5/8
1SVR405501R4010 .. CR-S048VDC1R ........................... 5/8
1SVR405501R4020 .. CR-S048VDC1RG ......................... 5/8
1SVR405501R5010 .. CR-S060VDC1R ........................... 5/8
1SVR405501R5020 .. CR-S060VDC1RG ......................... 5/8
1SVR405521R1100 .. CR-S006/024VDC1SS .................. 5/8
1SVR405521R1200 .. CR-S006/024VDC1SZ ................... 5/8
1SVR405521R3100 .. CR-S012/024VADC1SS................. 5/8
1SVR405521R3200 .. CR-S012/024VADC1SZ ................. 5/8
1SVR405521R5100 .. CR-S048/060VADC1SS................. 5/8
1SVR405521R5200 .. CR-S048/060VADC1SZ ................. 5/8
1SVR405521R6100 .. CR-S110/125VADC1SS................. 5/8
1SVR405521R6200 .. CR-S110/125VADC1SZ ................. 5/8
1SVR405521R7100 .. CR-S220/240VADC1SS................. 5/8
1SVR405521R7200 .. CR-S220/240VADC1SZ ................. 5/8
1SVR405541R3110 .. CR-S024VADC1CRS ..................... 5/8
1SVR405541R3120 .. CR-S024VADC1CRGS .................. 5/8
1SVR405541R3210 .. CR-S024VADC1CRZ ..................... 5/8
1SVR405541R3220 .. CR-S024VADC1CRGZ ................... 5/8
1SVR405541R6110 .. CR-S110VADC1CRS ..................... 5/8
1SVR405541R6120 .. CR-S110VADC1CRGS .................. 5/8
1SVR405541R6210 .. CR-S110VADC1CRZ ..................... 5/8
1SVR405541R6220 .. CR-S110VADC1CRGZ ................... 5/8
1SVR405541R7110 .. CR-S230VADC1CRS ..................... 5/8
1SVR405541R7120 .. CR-S230VADC1CRGS .................. 5/8
1SVR405541R7210 .. CR-S230VADC1CRZ ..................... 5/8
1SVR405541R7220 .. CR-S230VADC1CRGZ ................... 5/8
1SVR405598R0700 .. CR-SJB20-BLUE .......................... 5/8
1SVR405598R0800 .. CR-SJB20-RED ............................ 5/8
1SVR405598R0900 .. CR-SJB20-BLACK ........................ 5/8
1SVR405599R0000 .. CR-SSEP ...................................... 5/8
1SVR405600R0000 .. CR-P024AC1 ................................ 5/9
1SVR405600R1000 .. CR-P024DC1 ................................ 5/9
1SVR405600R2000 .. CR-P120AC1 ................................ 5/9
1SVR405600R3000 .. CR-P230AC1 ................................ 5/9
1SVR405600R4000 .. CR-P012DC1 ................................ 5/9
1SVR405600R5000 .. CR-P048AC1 ................................ 5/9
1SVR405600R6000 .. CR-P048DC1 ................................ 5/9
1SVR405600R7000 .. CR-P110AC1 ................................ 5/9
1SVR405600R8000 .. CR-P110DC1 ................................ 5/9
1SVR405601R0000 .. CR-P024AC2 ................................ 5/9
1SVR405601R1000 .. CR-P024DC2 ................................ 5/9
1SVR405601R2000 .. CR-P120AC2 ................................ 5/9
1SVR405601R3000 .. CR-P230AC2 ................................ 5/9
1SVR405601R4000 .. CR-P012DC2 ................................ 5/9
1SVR405601R5000 .. CR-P048AC2 ................................ 5/9
1SVR405601R6000 .. CR-P048DC2 ................................ 5/9
1SVR405601R7000 .. CR-P110AC2 ................................ 5/9
1SVR405601R8000 .. CR-P110DC2 ................................ 5/9
1SVR405606R0000 .. CR-P024AC2G ............................. 5/9
1SVR405606R1000 .. CR-P024DC2 ................................ 5/9
1SVR405606R3000 .. CR-P230AC2G ............................. 5/9
1SVR405606R7000 .. CR-P110AC2G ............................. 5/9
1SVR405611R0000 .. CR-M024AC2 ............................. 5/10
1SVR405611R0100 .. CR-M024AC2L ........................... 5/11
1SVR405611R1000 .. CR-M024DC2 ............................. 5/10
1SVR405611R1100 .. CR-M024DC2L ........................... 5/11
1SVR405611R2000 .. CR-M120AC2 ............................. 5/10
1SVR405611R2100 .. CR-M120AC2L ........................... 5/11
1SVR405611R3000 .. CR-M230AC2 ............................. 5/10
1SVR405611R3100 .. CR-M230AC2L ........................... 5/11
1SVR405611R4000 .. CR-M012DC2 ............................. 5/10
1SVR405611R4100 .. CR-M012DC2L ........................... 5/11
1SVR405611R4200 .. CR-M060DC2 ............................. 5/10
1SVR405611R4300 .. CR-M060DC2L ........................... 5/11
1SVR405611R5000 .. CR-M048AC2 ............................. 5/10
1SVR405611R5100 .. CR-M048AC2L ........................... 5/11
1SVR405611R6000 .. CR-M048DC2 ............................. 5/10
Order code Type Page Order code Type Page Order code Type Page
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/8
7
Index
Numerical
1SVR405611R6100 .. CR-M048DC2L ........................... 5/11
1SVR405611R7000 .. CR-M110AC2 ............................. 5/10
1SVR405611R7100 .. CR-M110AC2L ........................... 5/11
1SVR405611R8000 .. CR-M110DC2 ............................. 5/10
1SVR405611R8100 .. CR-M110DC2L ........................... 5/11
1SVR405611R8200 .. CR-M125DC2 ............................. 5/10
1SVR405611R8300 .. CR-M125DC2L ........................... 5/11
1SVR405611R9000 .. CR-M220DC2 ............................. 5/10
1SVR405611R9100 .. CR-M220DC2L ........................... 5/11
1SVR405612R0000 .. CR-M024AC3 ............................. 5/10
1SVR405612R0100 .. CR-M024AC3L ........................... 5/11
1SVR405612R1000 .. CR-M024DC3 ............................. 5/10
1SVR405612R1100 .. CR-M024DC3L ........................... 5/11
1SVR405612R2000 .. CR-M120AC3 ............................. 5/10
1SVR405612R2100 .. CR-M120AC3L ........................... 5/11
1SVR405612R3000 .. CR-M230AC3 ............................. 5/10
1SVR405612R3100 .. CR-M230AC3L ........................... 5/11
1SVR405612R4000 .. CR-M012DC3 ............................. 5/10
1SVR405612R4100 .. CR-M012DC3L ........................... 5/11
1SVR405612R4200 .. CR-M060DC3 ............................. 5/10
1SVR405612R4300 .. CR-M060DC3L ........................... 5/11
1SVR405612R5000 .. CR-M048AC3 ............................. 5/10
1SVR405612R5100 .. CR-M048AC3L ........................... 5/11
1SVR405612R5200 .. CR-M060AC3 ............................. 5/10
1SVR405612R6000 .. CR-M048DC3 ............................. 5/10
1SVR405612R6100 .. CR-M048DC3L ........................... 5/11
1SVR405612R7000 .. CR-M110AC3 ............................. 5/10
1SVR405612R7100 .. CR-M110AC3L ........................... 5/11
1SVR405612R8000 .. CR-M110DC3 ............................. 5/10
1SVR405612R8100 .. CR-M110DC3L ........................... 5/11
1SVR405612R8200 .. CR-M125DC3 ............................. 5/10
1SVR405612R8300 .. CR-M125DC3L ........................... 5/11
1SVR405612R9000 .. CR-M220DC3 ............................. 5/10
1SVR405612R9100 .. CR-M220DC3L ........................... 5/11
1SVR405613R0000 .. CR-M024AC4 ............................. 5/10
1SVR405613R0100 .. CR-M024AC4L ........................... 5/11
1SVR405613R1000 .. CR-M024DC4 ............................. 5/10
1SVR405613R1100 .. CR-M024DC4L ........................... 5/11
1SVR405613R2000 .. CR-M120AC4 ............................. 5/10
1SVR405613R2100 .. CR-M120AC4L ........................... 5/11
1SVR405613R3000 .. CR-M230AC4 ............................. 5/10
1SVR405613R3100 .. CR-M230AC4L ........................... 5/11
1SVR405613R4000 .. CR-M012DC4 ............................. 5/10
1SVR405613R4100 .. CR-M012DC4L ........................... 5/11
1SVR405613R4200 .. CR-M060DC4 ............................. 5/10
1SVR405613R4300 .. CR-M060DC4L ........................... 5/11
1SVR405613R5000 .. CR-M048AC4 ............................. 5/10
1SVR405613R5100 .. CR-M048AC4L ........................... 5/11
1SVR405613R6000 .. CR-M048DC4 ............................. 5/10
1SVR405613R6100 .. CR-M048DC4L ........................... 5/11
1SVR405613R7000 .. CR-M110AC4 ............................. 5/10
1SVR405613R7100 .. CR-M110AC4L ........................... 5/11
1SVR405613R8000 .. CR-M110DC4 ............................. 5/10
1SVR405613R8100 .. CR-M110DC4L ........................... 5/11
1SVR405613R8200 .. CR-M125DC4 ............................. 5/10
1SVR405613R8300 .. CR-M125DC4L ........................... 5/11
1SVR405613R9000 .. CR-M220DC4 ............................. 5/10
1SVR405613R9100 .. CR-M220DC4L ........................... 5/11
1SVR405614R1100 .. CR-M024DC4LD ......................... 5/11
1SVR405618R0000 .. CR-M024AC4G ........................... 5/11
1SVR405618R0100 .. CR-M024AC4LG ......................... 5/11
1SVR405618R1000 .. CR-M024DC4G........................... 5/11
1SVR405618R1100 .. CR-M024DC4LG ......................... 5/11
1SVR405618R1400 .. CR-M024DC4LDG ...................... 5/11
1SVR405618R2100 .. CR-M120AC4LG ......................... 5/11
1SVR405618R3000 .. CR-M230AC4G ........................... 5/11
1SVR405618R3100 .. CR-M230AC4LG ......................... 5/11
1SVR405618R4100 .. CR-M012DC4LG ......................... 5/11
1SVR405618R4300 .. CR-M060DC4LG ......................... 5/11
1SVR405618R4400 .. CR-M012DC4LDG ...................... 5/11
1SVR405618R5100 .. CR-M048AC4LG ......................... 5/11
1SVR405618R6100 .. CR-M048DC4LG ......................... 5/11
1SVR405618R7000 .. CR-M110AC4G ........................... 5/11
1SVR405618R7100 .. CR-M110AC4LG ......................... 5/11
1SVR405618R8100 .. CR-M110DC4LG ......................... 5/11
1SVR405618R8300 .. CR-M125DC4LG ......................... 5/11
1SVR405618R9100 .. CR-M220DC4LG ......................... 5/11
1SVR405621R0000 .. CR-U024AC2 .............................. 5/13
1SVR405621R0100 .. CR-U024AC2L ............................ 5/13
1SVR405621R1000 .. CR-U024DC2.............................. 5/13
1SVR405621R1100 .. CR-U024DC2L ............................ 5/13
1SVR405621R2000 .. CR-U120AC2 .............................. 5/13
1SVR405621R2100 .. CR-U120AC2L ............................ 5/13
1SVR405621R3000 .. CR-U230AC2 .............................. 5/13
1SVR405621R3100 .. CR-U230AC2L ............................ 5/13
1SVR405621R4000 CR-U012DC2.............................. 5/13
1SVR405621R4100 .. CR-U012DC2L ............................ 5/13
1SVR405621R5000 .. CR-U048AC2 .............................. 5/13
1SVR405621R5100 .. CR-U048AC2L ............................ 5/13
1SVR405621R6000 .. CR-U048DC2.............................. 5/13
1SVR405621R6100 .. CR-U048DC2L ............................ 5/13
1SVR405621R7000 .. CR-U110AC2 .............................. 5/13
1SVR405621R7100 .. CR-U110AC2L ............................ 5/13
1SVR405621R8000 .. CR-U110DC2.............................. 5/13
1SVR405621R8100 .. CR-U110DC2L ............................ 5/13
1SVR405621R9000 .. CR-U220DC2.............................. 5/13
1SVR405621R9100 .. CR-U220DC2L ............................ 5/13
1SVR405622R0000 .. CR-U024AC3 .............................. 5/13
1SVR405622R0100 .. CR-U024AC3L ............................ 5/13
1SVR405622R1000 .. CR-U024DC3.............................. 5/13
1SVR405622R1100 .. CR-U024DC3L ............................ 5/13
1SVR405622R2000 .. CR-U120AC3 .............................. 5/13
1SVR405622R2100 .. CR-U120AC3L ............................ 5/13
1SVR405622R3000 .. CR-U230AC3 .............................. 5/13
1SVR405622R3100 .. CR-U230AC3L ............................ 5/13
1SVR405622R4000 .. CR-U012DC3.............................. 5/13
1SVR405622R4100 .. CR-U012DC3L ............................ 5/13
1SVR405622R5000 .. CR-U048AC3 .............................. 5/13
1SVR405622R5100 .. CR-U048AC3L ............................ 5/13
1SVR405622R5200 .. CR-U060AC3 .............................. 5/13
1SVR405622R6000 .. CR-U048DC3.............................. 5/13
1SVR405622R6100 .. CR-U048DC3L ............................ 5/13
1SVR405622R7000 .. CR-U110AC3 .............................. 5/13
1SVR405622R7100 .. CR-U110AC3L ............................ 5/13
1SVR405622R8000 .. CR-U110DC3.............................. 5/13
1SVR405622R8100 .. CR-U110DC3L ............................ 5/13
1SVR405622R8200 .. CR-U125DC3.............................. 5/13
1SVR405622R9000 .. CR-U220DC3.............................. 5/13
1SVR405622R9100 .. CR-U220DC3L ............................ 5/13
1SVR405650R0000 .. CR-PLS ........................................ 5/9
1SVR405650R0100 .. CR-PLSx ...................................... 5/9
1SVR405650R0200 .. CR-PLC ........................................ 5/9
1SVR405650R1000 .. CR-PSS ........................................ 5/9
1SVR405651R0000 .. CR-P/M 22 ................................. 5/12
1SVR405651R1000 .. CR-M2SS ................................... 5/11
1SVR405651R1100 .. CR-M2LS ................................... 5/11
1SVR405651R1200 .. CR-M2LC ................................... 5/11
1SVR405651R1300 .. CR-M2SF ................................... 5/11
1SVR405651R2000 .. CR-M3SS ................................... 5/11
1SVR405651R2100 .. CR-M3LS ................................... 5/11
1SVR405651R3000 .. CR-M4SS ................................... 5/11
1SVR405651R3100 .. CR-M4LS ................................... 5/11
1SVR405651R3200 .. CR-M4LC ................................... 5/11
1SVR405651R3300 .. CR-M4SF ................................... 5/11
1SVR405652R0000 .. CR-P/M 42 ................................. 5/12
1SVR405652R1000 .. CR-P/M 42V ............................... 5/12
1SVR405652R4000 .. CR-P/M 42B ............................... 5/12
1SVR405652R4100 .. CR-P/M 42BV ............................. 5/12
1SVR405652R9000 .. CR-P/M 42C ............................... 5/12
1SVR405652R9100 .. CR-P/M 42CV ............................. 5/12
1SVR405653R0000 .. CR-P/M 52B ............................... 5/12
1SVR405653R1000 .. CR-P/M 52C ............................... 5/12
1SVR405653R4000 .. CR-P/M 52D ............................... 5/12
1SVR405654R0000 .. CR-P/M 62 ................................. 5/12
1SVR405654R0100 .. CR-P/M 92 ................................. 5/12
1SVR405654R1000 .. CR-P/M 62V ............................... 5/12
1SVR405654R1100 .. CR-P/M 92V ............................... 5/12
1SVR405654R4000 .. CR-P/M 62E ............................... 5/12
1SVR405654R4100 .. CR-P/M 62EV ............................. 5/12
1SVR405655R0000 .. CR-P/M 62C ............................... 5/12
1SVR405655R0100 .. CR-P/M 92C ............................... 5/12
1SVR405655R1000 .. CR-P/M 62CV ............................. 5/12
1SVR405655R1100 .. CR-P/M 92CV ............................. 5/12
Order code Type Page Order code Type Page Order code Type Page
2/9 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
7
1SVR405655R4000 .. CR-P/M 62D ............................... 5/12
1SVR405655R4100 .. CR-P/M 62DV ............................. 5/12
1SVR405656R0000 .. CR-P/M 72 ................................. 5/12
1SVR405656R1000 .. CR-P/M 72A ............................... 5/12
1SVR405656R2000 .. CR-P/M 82 ................................. 5/12
1SVR405658R0000 .. CR-PM ......................................... 5/9
1SVR405658R1000 .. CR-MM....................................... 5/11
1SVR405658R5000 .. CR-PJ .......................................... 5/9
1SVR405658R6000 .. CR-MJ ........................................ 5/11
1SVR405659R0000 .. CR-PH .......................................... 5/9
1SVR405659R1000 .. CR-MH ....................................... 5/11
1SVR405659R1100 .. CR-MH1 ..................................... 5/11
1SVR405660R0000 .. CR-U3S ...................................... 5/13
1SVR405660R0100 .. CR-U3E ...................................... 5/13
1SVR405660R1100 .. CR-U3SM ................................... 5/13
1SVR405661R0000 .. CR-U 21 ..................................... 5/14
1SVR405662R0000 .. CR-U 41 ..................................... 5/14
1SVR405662R1000 .. CR-U 41V ................................... 5/14
1SVR405662R4000 .. CR-U 41B ................................... 5/14
1SVR405662R4100 .. CR-U 41BV ................................. 5/14
1SVR405662R9000 .. CR-U 41C ................................... 5/14
1SVR405662R9100 .. CR-U 41CV ................................. 5/14
1SVR405663R0000 .. CR-U 51B ................................... 5/14
1SVR405663R1000 .. CR-U 51C ................................... 5/14
1SVR405663R4000 .. CR-U 51D ................................... 5/14
1SVR405664R0000 .. CR-U 61 ..................................... 5/14
1SVR405664R0100 .. CR-U 91 ..................................... 5/14
1SVR405664R1000 .. CR-U 61V ................................... 5/14
1SVR405664R1100 .. CR-U 91V ................................... 5/14
1SVR405664R4000 .. CR-U 61E ................................... 5/14
1SVR405664R4100 .. CR-U 61EV ................................. 5/14
1SVR405665R0000 .. CR-U 61C ................................... 5/14
1SVR405665R0100 .. CR-U 91C ................................... 5/14
1SVR405665R1000 .. CR-U 61CV ................................. 5/14
1SVR405665R1100 .. CR-U 91CV ................................. 5/14
1SVR405665R4000 .. CR-U 61D ................................... 5/14
1SVR405665R4100 .. CR-U 61DV ................................. 5/14
1SVR405666R0000 .. CR-U 71 ..................................... 5/14
1SVR405666R1000 .. CR-U 71A ................................... 5/14
1SVR405666R2000 .. CR-U 81 ..................................... 5/14
1SVR405667R0000 .. CR-U T ....................................... 5/14
1SVR405669R0000 .. CR-UH ....................................... 5/13
1SVR405670R0000 .. CR-U2S ...................................... 5/13
1SVR405670R1100 .. CR-U2SM ................................... 5/13
1SVR423418R9000 .. CP-RUD ..................................... 3/51
1SVR427014R0000 .. CP-S 24/5.0 ............................... 3/45
1SVR427015R0100 .. CP-S 24/10.0 ............................. 3/45
1SVR427016R0100 .. CP-S 24/20.0 ............................. 3/45
1SVR427024R0000 .. CP-C 24/5.0 ............................... 3/45
1SVR427025R0000 .. CP-C 24/10.0 ............................. 3/45
1SVR427026R0000 .. CP-C 24/20.0 ............................. 3/45
1SVR427030R0000 .. CP-E 24/0.75.............................. 3/20
1SVR427030R2000 .. CP-E 48/0.62.............................. 3/20
1SVR427031R0000 .. CP-E 24/1.25.............................. 3/20
1SVR427031R2000 .. CP-E 48/1.25.............................. 3/20
1SVR427032R0000 .. CP-E 24/2.5 ............................... 3/20
1SVR427032R1000 .. CP-E 12/2.5 ............................... 3/20
1SVR427033R3000 .. CP-E 5/3.0 ................................. 3/20
1SVR427034R0000 .. CP-E 24/5.0 ............................... 3/20
1SVR427034R2000 .. CP-E 48/5.0 ............................... 3/20
1SVR427035R0000 .. CP-E 24/10.0.............................. 3/20
1SVR427035R1000 .. CP-E 12/10.0.............................. 3/20
1SVR427035R2000 .. CP-E 48/10.0.............................. 3/20
1SVR427036R0000 .. CP-E 24/20.0.............................. 3/20
1SVR427041R0000 .. CP-D 24/0.42 ............................. 3/10
1SVR427041R0000 .. CP-D 24/0.42 ............................... 6/8
1SVR427041R1000 .. CP-D 12/0.83 ............................. 3/10
1SVR427043R0100 .. CP-D 24/1.3 ............................... 3/10
1SVR427043R0100 .. CP-D 24/1.3 ................................. 6/8
1SVR427043R1200 .. CP-D 12/2.1 ............................... 3/10
1SVR427044R0200 .. CP-D 24/2.5 ............................... 3/10
1SVR427045R0400 .. CP-D 24/4.2 ............................... 3/10
1SVR427049R0000 .. CP-D RU .................................... 3/51
1SVR427054R0000 .. CP-T 24/5.0 ................................ 3/34
1SVR427054R2000 .. CP-T 48/5.0 ................................ 3/34
1SVR427055R0000 .. CP-T 24/10.0 .............................. 3/34
1SVR427055R2000 .. CP-T 48/10.0 .............................. 3/34
1SVR427056R0000 .. CP-T 24/20.0 .............................. 3/34
1SVR427056R2000 .. CP-T 48/20.0 .............................. 3/34
1SVR427057R0000 .. CP-T 24/40.0 .............................. 3/34
1SVR427060R0300 .. CP-B 24/3.0 ............................... 3/68
1SVR427060R1000 .. CP-B 24/10.0 ............................. 3/68
1SVR427060R2000 .. CP-B 24/20.0 ............................. 3/68
1SVR427065R0000 .. CP-B EXT.2 ................................. 3/68
1SVR427071R0000 .. CP-A RU..................................... 3/51
1SVR427075R0000 .. CP-A CM .................................... 3/51
1SVR427081R0000 .. CP-C MM ................................... 3/45
1SVR427090R0280 .. CP-ASI/2.8 ................................. 3/60
1SVR427090R0400 .. CP-ASI/4.0 ................................. 3/60
1SVR427090R0800 .. CP-ASI/8.0 ................................. 3/60
1SVR427095R0400 .. CP-ASI/4.0 DC/DC ...................... 3/60
1SVR430005R0100 .. COV.01 ....................................... 1/40
1SVR430005R0100 .. COV.01 ..................................... 2/130
1SVR430005R0100 .. COV.01 ....................................... 4/22
1SVR430029R0100 .. ADP.01 ....................................... 1/40
1SVR430029R0100 .. ADP.01 ....................................... 1/40
1SVR430029R0100 .. ADP.01 ..................................... 2/130
1SVR430029R0100 .. ADP.01 ....................................... 4/22
1SVR430043R0000 .. MAR.02 ...................................... 1/40
1SVR430043R0000 .. MAR.02 .................................... 2/130
1SVR430851R0100 .. CM-ENS ................................... 2/115
1SVR430851R0200 .. CM-ENS UP/DOWN .................. 2/115
1SVR430851R1100 .. CM-ENS ................................... 2/115
1SVR430851R1200 .. CM-ENS UP/DOWN .................. 2/115
1SVR430851R1300 .. CM-ENS ................................... 2/115
1SVR430851R9100 .. CM-ENS ................................... 2/115
1SVR430851R9200 .. CM-ENS UP/DOWN .................. 2/115
1SVR440005R0100 .. COV.02 ..................................... 2/130
1SVR440029R0100 .. ADP.02 ..................................... 2/130
1SVR440709R0000 .. CL-LEC.CI000 .............................. 6/7
1SVR440709R5000 .. CL-LER.2O ................................... 6/7
1SVR440710R0200 .. CL-LSR.CX12DC1 ......................... 6/6
1SVR440710R0300 .. CL-LSR.C12DC1........................... 6/6
1SVR440711R0100 .. CL-LSR.12DC2 ............................. 6/6
1SVR440711R0200 .. CL-LSR.CX12DC2 ......................... 6/6
1SVR440711R0300 .. CL-LSR.C12DC2........................... 6/6
1SVR440711R1200 .. CL-LST.CX12DC2 ......................... 6/6
1SVR440711R1300 .. CL-LST.C12DC2 ........................... 6/6
1SVR440712R0200 .. CL-LSR.CX12AC1 ......................... 6/6
1SVR440712R0300 .. CL-LSR.C12AC1 ........................... 6/6
1SVR440713R0100 .. CL-LSR.12AC2 ............................. 6/6
1SVR440713R0200 .. CL-LSR.CX12AC2 ......................... 6/6
1SVR440713R0300 .. CL-LSR.C12AC2 ........................... 6/6
1SVR440720R0200 .. CL-LMR.CX18DC1 ........................ 6/7
1SVR440720R0300 .. CL-LMR.C18DC1 .......................... 6/7
1SVR440721R0000 .. CL-LER.18DC2 ............................. 6/7
1SVR440721R0200 .. CL-LMR.CX18DC2 ........................ 6/7
1SVR440721R0300 .. CL-LMR.C18DC2 .......................... 6/7
1SVR440721R1000 .. CL-LET.20DC2 .............................. 6/7
1SVR440721R1200 .. CL-LMT.CX20DC2 ......................... 6/7
1SVR440721R1300 .. CL-LMT.C20DC2 ........................... 6/7
1SVR440722R0200 .. CL-LMR.CX18AC1 ........................ 6/7
1SVR440722R0300 .. CL-LMR.C18AC1 .......................... 6/7
1SVR440723R0000 .. CL-LER.18AC2 ............................. 6/7
1SVR440723R0200 .. CL-LMR.CX18AC2 ........................ 6/7
1SVR440723R0300 .. CL-LMR.C18AC2 .......................... 6/7
1SVR440799R5000 .. CL-LAS.FD001 .............................. 6/8
1SVR440799R5100 .. CL-LAS.TK011 .............................. 6/8
1SVR440799R6000 .. CL-LAS.TK001 .............................. 6/8
1SVR440799R6100 .. CL-LAS.TK002 .............................. 6/8
1SVR440799R7000 .. CL-LAS.MD003 ............................. 6/8
1SVR440799R8000 .. CL-LAS.PS002 ............................. 6/8
1SVR440821R0000 .. CL-LDC.LDC2 ............................... 6/9
1SVR440821R1000 .. CL-LDC.LNDC2 ............................ 6/9
1SVR440823R0000 .. CL-LDC.LAC2 ............................... 6/9
1SVR440823R1000 .. CL-LDC.LNAC2 ............................ 6/9
1SVR440839R4400 .. CL-LDD.K ..................................... 6/6
1SVR440839R4400 .. CL-LDD.K ..................................... 6/9
1SVR440839R4500 .. CL-LDD.XK ................................... 6/6
1SVR440839R4500 .. CL-LDD.XK ................................... 6/9
1SVR440841R0000 .. CL-LDC.SDC2 .............................. 6/6
1SVR440843R0000 .. CL-LDC.SAC2 .............................. 6/6
1SVR440851R0000 .. CL-LDR.16DC2 ............................. 6/9
Index
Numerical
Order code Type Page Order code Type Page Order code Type Page
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/10
7
1SVR440851R1000 .. CL-LDT.16DC2 ............................. 6/9
1SVR440851R2000 .. CL-LDR.17DC2 ............................. 6/9
1SVR440851R3000 .. CL-LDT.17DC2 ............................. 6/9
1SVR440853R0000 .. CL-LDR.16AC2 ............................. 6/9
1SVR440899R1000 .. CL-LAD.FD001 ............................. 6/9
1SVR440899R2000 .. CL-LAD.FD011 ............................. 6/9
1SVR440899R3000 .. CL-LAD.FD002 ............................. 6/9
1SVR440899R6000 .. CL-LAD.TK001 ............................. 6/9
1SVR440899R6100 .. CL-LAD.TK002 ............................. 6/9
1SVR440899R6200 .. CL-LAD.TK003 ............................. 6/9
1SVR440899R6300 .. CL-LAD.TK004 ............................. 6/9
1SVR440899R6400 .. CL-LAD.TK005 ............................. 6/9
1SVR440899R6500 .. CL-LAD.TK006 ............................. 6/9
1SVR440899R6600 .. CL-LAD.TK007 ............................. 6/8
1SVR440899R6700 .. CL-LAD.TK011 ............................. 6/9
1SVR440899R6900 .. CL-LAD.TK009 ............................. 6/9
1SVR440899R7000 .. CL-LAD.MD004 ............................ 6/9
1SVR450050R0000 .. CM-ENN ................................... 2/115
1SVR450051R0000 .. CM-ENN ................................... 2/115
1SVR450055R0000 .. CM-ENN ................................... 2/115
1SVR450056R0000 .. CM-SE-300 .............................. 2/116
1SVR450056R0100 .. CM-SE-600 .............................. 2/116
1SVR450056R0200 .. CM-SE-1000............................. 2/116
1SVR450056R6000 .. CM-KH-3 .................................. 2/116
1SVR450056R7000 .. CM-AH-3 .................................. 2/116
1SVR450056R8000 .. CM-GM-1 ................................. 2/116
1SVR450059R0000 .. CM-ENN ................................... 2/115
1SVR450116R1000 .. CM-CT 50/1 ............................. 2/131
1SVR450116R1100 .. CM-CT 75/1 ............................. 2/131
1SVR450116R1200 .. CM-CT 100/1............................ 2/131
1SVR450116R1300 .. CM-CT 150/1............................ 2/131
1SVR450116R1400 .. CM-CT 200/1............................ 2/131
1SVR450116R5000 .. CM-CT 50/5 ............................. 2/131
1SVR450116R5100 .. CM-CT 75/5 ............................. 2/131
1SVR450116R5200 .. CM-CT 100/5............................ 2/131
1SVR450116R5300 .. CM-CT 150/5............................ 2/131
1SVR450116R5400 .. CM-CT 200/5............................ 2/131
1SVR450117R1100 .. CM-CT 300/1............................ 2/131
1SVR450117R1200 .. CM-CT 400/1............................ 2/131
1SVR450117R1300 .. CM-CT 500/1............................ 2/131
1SVR450117R1400 .. CM-CT 600/1............................ 2/131
1SVR450117R5100 .. CM-CT 300/5............................ 2/131
1SVR450117R5200 .. CM-CT 400/5............................ 2/131
1SVR450117R5300 .. CM-CT 500/5............................ 2/131
1SVR450117R5400 .. CM-CT 600/5............................ 2/131
1SVR450118R1000 .. CM-CT A .................................. 2/131
1SVR450330R0000 .. CM-LWN..................................... 2/76
1SVR450330R0100 .. CM-LWN..................................... 2/76
1SVR450331R0000 .. CM-LWN..................................... 2/76
1SVR450331R0100 .. CM-LWN..................................... 2/76
1SVR450332R0000 .. CM-LWN..................................... 2/76
1SVR450332R0100 .. CM-LWN..................................... 2/76
1SVR450334R0000 .. CM-LWN..................................... 2/76
1SVR450334R0100 .. CM-LWN..................................... 2/76
1SVR450335R0000 .. CM-LWN..................................... 2/76
1SVR450335R0100 .. CM-LWN..................................... 2/76
1SVR500020R0000 .. CT-MFD.12 ................................... 1/8
1SVR500020R1100 .. CT-MFD.21 ................................... 1/8
1SVR500100R0000 .. CT-ERD.12.................................... 1/8
1SVR500100R0100 .. CT-ERD.22.................................... 1/8
1SVR500110R0000 .. CT-AHD.12 ................................... 1/8
1SVR500110R0100 .. CT-AHD.22 ................................... 1/8
1SVR500130R0000 .. CT-VWD.12 ................................... 1/8
1SVR500150R0000 .. CT-EBD.12.................................... 1/8
1SVR500160R0000 .. CT-TGD.12 ................................... 1/8
1SVR500160R0100 .. CT-TGD.22 ................................... 1/8
1SVR500210R0100 .. CT-SAD.22.................................... 1/8
1SVR500211R0100 .. CT-SDD.22 ................................... 1/8
1SVR510730R0300 .. CM-UFD.M22.............................. 2/54
1SVR510730R0300 .. CM-UFD.M31.............................. 2/54
1SVR550019R0000 .. CT-MKE ...................................... 1/21
1SVR550029R8100 .. CT-MFE ...................................... 1/20
1SVR550100R1100 .. CT-ERE ....................................... 1/20
1SVR550100R2100 .. CT-ERE ....................................... 1/20
1SVR550100R4100 .. CT-ERE ....................................... 1/20
1SVR550100R5100 .. CT-ERE ....................................... 1/20
1SVR550107R1100 .. CT-ERE ....................................... 1/20
1SVR550107R2100 .. CT-ERE ....................................... 1/20
1SVR550107R4100 .. CT-ERE ....................................... 1/20
1SVR550107R5100 .. CT-ERE ....................................... 1/20
1SVR550110R1100 .. CT-AHE ...................................... 1/20
1SVR550110R2100 .. CT-AHE ...................................... 1/20
1SVR550110R4100 .. CT-AHE ...................................... 1/20
1SVR550111R1100 .. CT-AHE ...................................... 1/20
1SVR550111R2100 .. CT-AHE ...................................... 1/20
1SVR550111R4100 .. CT-AHE ...................................... 1/20
1SVR550118R1100 .. CT-AHE ...................................... 1/20
1SVR550118R2100 .. CT-AHE ...................................... 1/20
1SVR550118R4100 .. CT-AHE ...................................... 1/20
1SVR550120R1100 .. CT-ARE ...................................... 1/20
1SVR550120R4100 .. CT-ARE ...................................... 1/20
1SVR550127R1100 .. CT-ARE ...................................... 1/20
1SVR550127R4100 .. CT-ARE ...................................... 1/20
1SVR550130R1100 .. CT-VWE ...................................... 1/20
1SVR550130R2100 .. CT-VWE ...................................... 1/20
1SVR550130R4100 .. CT-VWE ...................................... 1/20
1SVR550137R1100 .. CT-VWE ...................................... 1/20
1SVR550137R2100 .. CT-VWE ...................................... 1/20
1SVR550137R4100 .. CT-VWE ...................................... 1/20
1SVR550140R1100 .. CT-AWE ..................................... 1/21
1SVR550140R2100 .. CT-AWE ..................................... 1/21
1SVR550140R4100 .. CT-AWE ..................................... 1/21
1SVR550141R1100 .. CT-AWE ..................................... 1/21
1SVR550141R2100 .. CT-AWE ..................................... 1/21
1SVR550141R4100 .. CT-AWE ..................................... 1/21
1SVR550148R1100 .. CT-AWE ..................................... 1/21
1SVR550148R2100 .. CT-AWE ..................................... 1/21
1SVR550148R4100 .. CT-AWE ..................................... 1/21
1SVR550150R3100 .. CT-AWE ...................................... 1/20
1SVR550151R3100 .. CT-AWE ...................................... 1/20
1SVR550158R3100 .. CT-AWE ...................................... 1/20
1SVR550160R1100 .. CT-EBE ....................................... 1/21
1SVR550167R1100 .. CT-EBE ....................................... 1/21
1SVR550200R1100 .. CT-YDE ...................................... 1/21
1SVR550200R2100 .. CT-YDE ...................................... 1/21
1SVR550200R4100 .. CT-YDE ...................................... 1/21
1SVR550207R1100 .. CT-YDE ...................................... 1/21
1SVR550207R2100 .. CT-YDE ...................................... 1/21
1SVR550207R4100 .. CT-YDE ...................................... 1/21
1SVR550210R4100 .. CT-SDE ...................................... 1/21
1SVR550212R4100 .. CT-SDE ...................................... 1/21
1SVR550217R4100 .. CT-SDE ...................................... 1/21
1SVR550509R1000 .. CT-EKE ....................................... 1/21
1SVR550509R2000 .. CT-EKE ....................................... 1/21
1SVR550509R4000 .. CT-EKE ....................................... 1/21
1SVR550519R1000 .. CT-AKE ....................................... 1/21
1SVR550519R2000 .. CT-AKE ....................................... 1/21
1SVR550519R4000 .. CT-AKE ....................................... 1/21
1SVR550800R9300 .. CM-MSE ..................................... 2/90
1SVR550801R9300 .. CM-MSE ..................................... 2/90
1SVR550805R9300 .. CM-MSE ..................................... 2/90
1SVR550824R9100 .. CM-PFE ...................................... 2/33
1SVR550850R9400 .. CM-ENE MAX ........................... 2/115
1SVR550850R9500 .. CM-ENE MIN ............................ 2/115
1SVR550851R9400 .. CM-ENE MAX ........................... 2/115
1SVR550851R9500 .. CM-ENE MIN ............................ 2/115
1SVR550855R9400 .. CM-ENE MAX ........................... 2/115
1SVR550855R9500 .. CM-ENE MIN ............................ 2/115
1SVR550870R9400 .. CM-PVE ..................................... 2/33
1SVR550871R9500 .. CM-PVE ..................................... 2/33
1SVR550881R9400 .. CM-PBE ..................................... 2/33
1SVR550882R9500 .. CM-PBE ..................................... 2/33
1SVR560730R3400 .. CM-UFD.M33.............................. 2/54
1SVR700101R0100 .. C512-D .................................... 2/104
1SVR700102R0100 .. C512-E ..................................... 2/104
1SVR700111R0100 .. C513-D .................................... 2/104
1SVR700112R0100 .. C513-E ..................................... 2/104
1SVR730005R0100 .. COV.11 ....................................... 1/40
1SVR730005R0100 .. COV.11 ..................................... 2/130
1SVR730006R0000 .. MAR.12 ...................................... 1/40
1SVR730006R0000 .. MAR.12 .................................... 2/130
1SVR730010R0200 .. CT-MFS.21 ................................. 1/37
1SVR730010R3200 .. CT-MBS.22S ............................... 1/37
Index
Numerical
Order code Type Page Order code Type Page Order code Type Page
2/11 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
7
1SVR730020R0200 .. CT-MVS.21S ............................... 1/37
1SVR730020R3100 .. CT-MVS.12S ............................... 1/37
1SVR730020R3300 .. CT-MVS.22S ............................... 1/37
1SVR730021R2300 .. CT-MVS.23S ............................... 1/37
1SVR730030R3300 .. CT- MXS.22S .............................. 1/37
1SVR730040R3300 .. CT-WBS.22S............................... 1/37
1SVR730100R0300 .. CT-ERS.21S................................ 1/38
1SVR730100R3100 .. CT-ERS.12S................................ 1/38
1SVR730100R3300 .. CT-ERS.22S................................ 1/38
1SVR730110R3300 .. CT-AHS.22S ............................... 1/38
1SVR730120R3100 .. CT-ARS.11S ............................... 1/38
1SVR730120R3300 .. CT-ARS.21S ............................... 1/38
1SVR730180R0300 .. CT-APS.21S................................ 1/38
1SVR730180R3100 .. CT-APS.12S................................ 1/38
1SVR730180R3300 .. CT-APS.22S................................ 1/38
1SVR730210R3300 .. CT-SDS.22S ............................... 1/38
1SVR730211R2300 .. CT-SDS.23S ............................... 1/38
1SVR730660R0100 .. CM-IWS.1S ................................. 2/66
1SVR730670R0200 .. CM-IWS.2S ................................. 2/66
1SVR730700R0100 .. CM-MSS.12S .............................. 2/90
1SVR730700R0200 .. CM-MSS.22S .............................. 2/90
1SVR730700R2100 .. CM-MSS.13S .............................. 2/90
1SVR730700R2200 .. CM-MSS.23S .............................. 2/90
1SVR730712R0200 .. CM-MSS.32S .............................. 2/90
1SVR730712R1200 .. CM-MSS.41S .............................. 2/90
1SVR730712R1300 .. CM-MSS.51S .............................. 2/90
1SVR730712R1400 .. CM-MSS.31S .............................. 2/90
1SVR730712R2200 .. CM-MSS.33S .............................. 2/90
1SVR730720R1400 .. CM-MSS.11S .............................. 2/90
1SVR730722R1400 .. CM-MSS.21S .............................. 2/90
1SVR730740R0100 .. CM-TCS.11S ........................... 2/104
1SVR730740R0200 .. CM-TCS.12S ........................... 2/104
1SVR730740R0300 .. CM-TCS.13S ........................... 2/104
1SVR730740R9100 .. CM-TCS.21S ........................... 2/104
1SVR730740R9200 .. CM-TCS.22S ........................... 2/104
1SVR730740R9300 .. CM-TCS.23S ........................... 2/104
1SVR730750R0400 .. CM-EFS.2S................................. 2/16
1SVR730760R0400 .. CM-SFS.21S............................... 2/15
1SVR730760R0500 .. CM-SFS.22S............................... 2/15
1SVR730774R1300 .. CM-PAS.31S .............................. 2/33
1SVR730774R3300 .. CM-PAS.41S .............................. 2/33
1SVR730784R2300 .. CM-PSS.31S .............................. 2/33
1SVR730784R3300 .. CM-PSS.41S .............................. 2/33
1SVR730794R1300 .. CM-PVS.31S .............................. 2/33
1SVR730794R2300 .. CM-PVS.81S .............................. 2/33
1SVR730794R3300 .. CM-PVS.41S .............................. 2/33
1SVR730824R9300 .. CM-PFS.S ................................. 2/33
1SVR730830R0300 .. CM-ESS.1S ................................ 2/16
1SVR730830R0400 .. CM-ESS.2S ................................ 2/16
1SVR730830R0500 .. CM-ESS.MS ............................... 2/16
1SVR730831R0300 .. CM-ESS.1S ................................ 2/16
1SVR730831R0400 .. CM-ESS.2S ................................ 2/16
1SVR730831R1300 .. CM-ESS.1S ................................ 2/16
1SVR730831R1400 .. CM-ESS.2S ................................ 2/16
1SVR730840R0200 .. CM-SRS.11S .............................. 2/15
1SVR730840R0300 .. CM-SRS.12S .............................. 2/15
1SVR730840R0400 .. CM-SRS.21S .............................. 2/15
1SVR730840R0500 .. CM-SRS.22S .............................. 2/15
1SVR730840R0600 .. CM-SRS.M1S ............................. 2/15
1SVR730840R0700 .. CM-SRS.M2S ............................. 2/15
1SVR730841R0200 .. CM-SRS.11S .............................. 2/15
1SVR730841R0300 .. CM-SRS.12S .............................. 2/15
1SVR730841R0400 .. CM-SRS.21S .............................. 2/15
1SVR730841R0500 .. CM-SRS.22S .............................. 2/15
1SVR730841R1200 .. CM-SRS.11S .............................. 2/15
1SVR730841R1300 .. CM-SRS.12S .............................. 2/15
1SVR730841R1400 .. CM-SRS.21S .............................. 2/15
1SVR730841R1500 .. CM-SRS.22S .............................. 2/15
1SVR730884R1300 .. CM-MPS.31S .............................. 2/34
1SVR730884R3300 .. CM-MPS.41S .............................. 2/34
1SVR730884R4300 .. CM-MPS.43S .............................. 2/34
1SVR730885R1300 .. CM-MPS.11S .............................. 2/34
1SVR730885R3300 .. CM-MPS.21S .............................. 2/34
1SVR730885R4300 .. CM-MPS.23S .............................. 2/34
1SVR740010R0200 .. CT-MFS.21P ............................... 1/37
1SVR740010R3200 .. CT-MBS.22P ............................... 1/37
1SVR740020R0200 .. CT-MVS.21P ............................... 1/37
1SVR740020R3100 .. CT-MVS.12P ............................... 1/37
1SVR740020R3300 .. CT-MVS.22P ............................... 1/37
1SVR740021R2300 .. CT-MVS.23P ............................... 1/37
1SVR740030R3300 .. CT-MXS.22P ............................... 1/37
1SVR740040R3300 .. CT-WBS.22P............................... 1/37
1SVR740100R0300 .. CT-ERS.21P................................ 1/38
1SVR740100R3100 .. CT-ERS.12P................................ 1/38
1SVR740100R3300 .. CT-ERS.22P................................ 1/38
1SVR740110R3300 .. CT-AHS.22P ............................... 1/38
1SVR740120R3100 .. CT-ARS.11P ............................... 1/38
1SVR740120R3300 .. CT-ARS.21P ............................... 1/38
1SVR740180R0300 .. CT-APS.21P................................ 1/38
1SVR740180R3100 .. CT-APS.12P................................ 1/38
1SVR740180R3300 .. CT-APS.22P................................ 1/38
1SVR740210R3300 .. CT-SDS.22P ............................... 1/38
1SVR740211R2300 .. CT-SDS.23P ............................... 1/38
1SVR740660R0100 .. CM-IWS.1P ................................. 2/66
1SVR740670R0200 .. CM-IWS.2P ................................. 2/66
1SVR740700R0100 .. CM-MSS.12P .............................. 2/90
1SVR740700R0200 .. CM-MSS.22P .............................. 2/90
1SVR740700R2100 .. CM-MSS.13P .............................. 2/90
1SVR740700R2200 .. CM-MSS.23P .............................. 2/90
1SVR740712R0200 .. CM-MSS.32P .............................. 2/90
1SVR740712R1200 .. CM-MSS.41P .............................. 2/90
1SVR740712R1300 .. CM-MSS.51P .............................. 2/90
1SVR740712R1400 .. CM-MSS.31P .............................. 2/90
1SVR740712R2200 .. CM-MSS.33P .............................. 2/90
1SVR740720R1400 .. CM-MSS.11P .............................. 2/90
1SVR740722R1400 .. CM-MSS.21P .............................. 2/90
1SVR740740R0100 .. CM-TCS.11P ........................... 2/104
1SVR740740R0200 .. CM-TCS.12P ........................... 2/104
1SVR740740R0300 .. CM-TCS.13P ........................... 2/104
1SVR740740R9100 .. CM-TCS.21P ........................... 2/104
1SVR740740R9200 .. CM-TCS.22P ........................... 2/104
1SVR740740R9300 .. CM-TCS.23P ........................... 2/104
1SVR740750R0400 .. CM-EFS.2P................................. 2/16
1SVR740760R0400 .. CM-SFS.21P............................... 2/15
1SVR740774R1300 .. CM-PAS.31P .............................. 2/33
1SVR740774R3300 .. CM-PAS.41P .............................. 2/33
1SVR740784R2300 .. CM-PSS.31P .............................. 2/33
1SVR740784R3300 .. CM-PSS.41P .............................. 2/33
1SVR740794R1300 .. CM-PVS.31P .............................. 2/33
1SVR740794R2300 .. CM-PVS.81P .............................. 2/33
1SVR740794R3300 .. CM-PVS.41P .............................. 2/33
1SVR740824R9300 .. CM-PFS.P .................................. 2/33
1SVR740830R0300 .. CM-ESS.1P ................................ 2/16
1SVR740830R0400 .. CM-ESS.2P ................................ 2/16
1SVR740830R0500 .. CM-ESS.MP ............................... 2/16
1SVR740831R0300 .. CM-ESS.1P ................................ 2/16
1SVR740831R0400 .. CM-ESS.2P ................................ 2/16
1SVR740831R1300 .. CM-ESS.1P ................................ 2/16
1SVR740831R1400 .. CM-ESS.2P ................................ 2/16
1SVR740840R0200 .. CM-SRS.11P .............................. 2/15
1SVR740840R0400 .. CM-SRS.21P .............................. 2/15
1SVR740840R0600 .. CM-SRS.M1P ............................. 2/15
1SVR740841R0200 .. CM-SRS.11P .............................. 2/15
1SVR740841R0400 .. CM-SRS.21P .............................. 2/15
1SVR740841R1200 .. CM-SRS.11P .............................. 2/15
1SVR740841R1400 .. CM-SRS.21P .............................. 2/15
1SVR740884R1300 .. CM-MPS.31P .............................. 2/34
1SVR740884R3300 .. CM-MPS.41P .............................. 2/34
1SVR740884R4300 .. CM-MPS.43P .............................. 2/34
1SVR740885R1300 .. CM-MPS.11P .............................. 2/34
1SVR740885R3300 .. CM-MPS.21P .............................. 2/34
1SVR740885R4300 .. CM-MPS.23P .............................. 2/34
1SVR750005R0100 .. COV.12 ..................................... 2/130
1SVR750487R8300 .. CM-MPN.52S ............................. 2/34
1SVR750488R8300 .. CM-MPN.62S ............................. 2/34
1SVR750489R8300 .. CM-MPN.72S ............................. 2/34
1SVR750660R0200 .. CM-IWN.1S ................................ 2/66
1SVR750660R0300 .. CM-IWN.4S ................................ 2/66
1SVR750660R0400 .. CM-IWN.5S ................................ 2/66
1SVR750660R0500 .. CM-IWN.6S ................................ 2/66
1SVR750669R9400 .. CM-IVN.S ................................... 2/66
1SVR760487R8300 .. CM-MPN.52P ............................. 2/34
1SVR760488R8300 .. CM-MPN.62P ............................. 2/34
Index
Numerical
Order code Type Page Order code Type Page Order code Type Page
2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 2/12
7
1SVR760489R8300 .. CM-MPN.72P ............................. 2/34
1SVR760660R0200 .. CM-IWN.1P ................................ 2/66
1SVR760660R0300 .. CM-IWN.4P ................................ 2/66
1SVR760660R0400 .. CM-IWN.5P ................................ 2/66
1SVR760660R0500 .. CM-IWN.6P ................................ 2/66
1SVR760669R9400 .. CM-IVN.P ................................... 2/66
2CDE
2CDE601101R2001 .. EPD24-TB-101-1A ...................... 3/75
2CDE601101R2002 .. EPD24-TB-101-2A ...................... 3/75
2CDE601101R2003 .. EPD24-TB-101-3A ...................... 3/75
2CDE601101R2004 .. EPD24-TB-101-4A ...................... 3/75
2CDE601101R2006 .. EPD24-TB-101-6A ...................... 3/75
2CDE601101R2008 .. EPD24-TB-101-8A ...................... 3/75
2CDE601101R2010 .. EPD24-TB-101-10A .................... 3/75
2CDE601101R2012 .. EPD24-TB-101-12A .................... 3/75
2CDE601101R2905 .. EPD24-TB-101-0.5A ................... 3/75
2CDE605100R0500 .. EPD-BB500 ................................ 3/75
2CDE605200R0021 .. EPD-SB21 .................................. 3/75
GJD
GJD6155620R0087 .. SK 615 562-87 ........................... 1/39
GJD6155620R0088 .. SK 615 562-88 ........................... 1/39
Index
Numerical
Order code Type Page
Contact us
ABB STOTZ-KONTAKT GmbHYou can find the address of your local sales organisation
on the ABB homepage:
www.abb.com/contacts > Low Voltage Products and Systems
Find out more about Electronic Products and Relays on:
http://new.abb.com/low-voltage/products/epr
DE
AB
B 2
CD
C 1
10
00
4 C
02
10
Rev A
prin
ted
in
Fed
era
l R
ep
ub
lic o
f G
erm
an
y (
03
/20
15
)Note: We reserve the right to make technical changes or
modify the contents of this document without prior notice.
With regard to purchase orders, the agreed particulars shal l
prevai l. ABB AG does not accept any responsibility whatsoever
for potential errors or possible lack of information in this document.
We reserve all rights in this document and in the subject matter
and illustrations contained therein. Any reproduction, disclosure
to third parties or utilization of its contents – in whole or in parts –
is forbidden without prior written consent of ABB AG.
Copyright © 2015 ABB