Catalog English 2012

download Catalog English 2012

of 23

Transcript of Catalog English 2012

  • 8/13/2019 Catalog English 2012

    1/23

    Our corporate philosophy is to maximize value by customer-friendlydesign. For this purpose, we are including every customer needsfor various applications in our product design in order to provide ourcustomers best detectors, best service. It is the reason that we canmanufacture the world best detectors as well as world best quality.

    Best Detectors,Best Service

    C-910C, Bupyeong Woolim Lions Valley, #425 Cheongcheon-Dong, Bupyeong-Gu, Incheon, KoreaTel. +82-32-623-7507 / Fax. +82-32-623-7510

    Web. www.gasdna.com Email. [email protected]

  • 8/13/2019 Catalog English 2012

    2/23

  • 8/13/2019 Catalog English 2012

    3/23

    Installation-Type Infrared Thermometer

    IR-40_ 04 IR-21_ 04 IR-20_ 05 IR-80_ 05 6-IRman_ 06 10-IRman_ 06

    IR-80-H_ 07 Ascon Infrared Thermometer_ 07 Infrared Thermometer-Accessories_07

    Portable Infrared Thermometer

    PIR550_08 PIR1500_08 PIR2400_08

    Installation-Type Gas Detector

    DI-20 Series_09

    DA-91 Series_09

    SMART Gas detector

    DA-500_ 10 DA-100_ 10 DA-800_ 11 DA-750_ 11 DA-50_ 12

    Radio Environment Air Quality Monitor

    IAQ-700_ 12

    NH3,CH4,CO2-Raser Gas Monitor_ LGD F200_ 13

    Smoke Senser

    SD-110_ 13 SD-50_ 14

    Single-type Gas Detector Receiving Unit

    GMS-1000_ 14

    4-Channel Gas Detector Receiving Unit

    GMS-1500_ 15

    Multiple-type Gas Detector Receiving Unit

    GMS-2000_ 15

    CONTENTS

  • 8/13/2019 Catalog English 2012

    4/23

    04

    Installation-Type Infrared Thermometer

    Segment IR-40

    Range 0~1,000

    Resolution 0.1Emissivity 0.1~0.99

    Response Time Within 0.5 sec.

    Accuracy 2 or 1%

    Field of View (D:S) 40:1

    Wavelength Range 8~14

    Input Power 12V~24V

    External Material Aluminum

    Cable Length 3M

    Segment IR-21

    Range 0~400

    Resolution 0.1

    Emissivity 0.95(Fixed)

    Response Time Within 0.5 sec.

    Accuracy 2 or1%

    Field of View (D:S) 12:1

    Wavelength Range 8~14

    Input Power 12V~24V

    External Material Aluminum

    Cable Length 3M

    Model Description

    Code A Temperature range

    1 0~1000

    2 0~700

    3 -20~1000

    Z Other

    Code B Output

    M DC 0~20mA

    N DC 4-20mA

    V Voltage output DC 1~5V

    Z Other

    CODE C Cable length

    1 3M

    Z Other

    Model Description

    Code A Temperature range

    1 0~400

    2 0~700

    3 -20~700

    Z Other

    Code B Output

    M DC 0~20mA

    N DC 4-20mA

    V Voltage output DC 1~5V

    Z Other

    CODE C Cable length

    1 3M

    Z Other

    22

    59

    DISTANCE: SENSOR TO OBJECT (IN)

    D:S=40:1

    SPOTDIA.*

    (MM)

    SPOTDIA.*

    (IN)

    DISTANCE: SENSOR TO OBJECT (MM)

    *FOCUS POINT D:S = 40:1 FAR FIELD D:S = 40:1

    0.9

    15001000500

    28

    44

    1.1

    1.7

    4020

    18

    1000

    83

    8

    3.3

    20 40

    DISTANCE: SENSOR TO OBJECT (IN)

    D:S=12:1

    SPOTDIA.*

    (MM)

    SPOTDIA.*

    (IN)

    DISTANCE: SENSOR TO OBJECT (MM)

    *FOCUS POINT D:S = 12:1 FAR FIELD D:S = 12:1

    0.3

    500250100

    21

    42

    0.8

    1.7

    104

    Product Specification

    Product Specification

    Optical Field of View

    Optical Field of View

    Dimension

    Dimension

    Code Number IR-40---

    Code Number IR-21---

    IR-40

    IR-21

    Non-contact infrared thermometer

    Non-contact infrared thermometer

  • 8/13/2019 Catalog English 2012

    5/23

    05

    Installation-Type Infrared Thermometer

    Segment IR-20

    Range 0~400

    Resolution 0.1Emissivity 0.95(Fixed)

    Response Time Within 0.5 sec.

    Accuracy 2 or1%

    Field of View (D:S) 10:1

    Wavelength Range 8~14

    Input Power 12V~24V

    External Material Aluminum

    Cable Length 3M

    Segment IR-80

    Range 500~1700

    Resolution 0.1

    Emissivity 0.1~0.99

    Response Time Within 0.1 sec.

    Accuracy 2 or1%

    Field of View (D:S) 80:1

    Wavelength Range 0.9~1.5

    Input Power 12V~24V

    External Material Aluminum

    Cable Length 3M

    Model Description

    Code A Temperature range

    1 0~400

    2 0~200

    Z Other

    Code B Output

    N DC 4-20mA

    V Voltage output DC 1~5V

    Z Other

    CODE C Cable length

    1 3M

    Z Other

    Model Description

    Code A Temperature range

    1 500~1500

    2 500~1700

    3 250~650

    Z Other

    Code B Output

    M DC 0~20mA

    N DC 4-20mA

    V Voltage output DC 1~5V

    Z Other

    CODE C Cable length

    1 3M

    Z Other

    1000

    100

    10

    4.0

    20 40

    DISTANCE: SENSOR TO OBJECT (IN)

    D:S=10:1

    SPOTDIA.*

    (MM)

    SPOTDIA.*

    (IN)

    DISTANCE: SENSOR TO OBJECT (MM)

    *FOCUS POINT D:S = 10:1 FAR FIELD D:S = 10:1

    0.4

    500250100

    25

    50

    1.0

    2.0

    104

    2000

    25

    6

    1.0

    59 79

    DISTANCE: SENSOR TO OBJECT (IN)

    D:S=80:1

    SPOTDIA.*

    (MM)

    SPOTDIA.*

    (IN)

    DISTANCE: SENSOR TO OBJECT (MM)

    *FOCUS POINT D:S = 80:1 FAR FIELD D:S = 80:1

    0.2

    15001000500

    13

    19

    0.5

    0.7

    4020

    Product Specification

    Product Specification

    Optical Field of View

    Optical Field of View

    Dimension

    Dimension

    Code Number IR-20---

    Code Number IR-80---

    IR-20

    IR-80

    Non-contact infrared thermometer

    Non-contact infrared thermometer

  • 8/13/2019 Catalog English 2012

    6/23

    06

    Segment 6-IRman

    Range -20~600

    Resolution 0.1Emissivity 0.1~0.99

    Response Time Within 0.5 sec.

    Accuracy 2 or1%

    Field of View (D:S) 10:1

    Wavelength Range 8~14

    Input Power 12V~24V

    Cable Length 3M

    Segment 10-IRman

    Range -20~1000

    Resolution 0.1

    Emissivity 0.1~0.99

    Response Time Within 0.5 sec.

    Accuracy 2 or1%

    Field of View (D:S) 40:1

    Wavelength Range 8~14

    Input Power 12V~24V

    External Material Aluminum

    Cable Length 3M

    Model Description

    Code A Temperature range

    1 -20~600

    2 -20~400

    3 0~100

    Z Other

    Code B output

    M DC 0~20mA

    N DC 4-20mA

    Z Other

    CODE C Cable length

    1 3M

    Z Other

    Model Description

    Code A Temperature range

    1 -20~1000

    2 0~500

    3 0~100

    Z Other

    Code B output

    M DC 0~20mA

    N DC 4-20mA

    Z Other

    CODE C Cable length

    1 3M

    Z Other

    1000

    100

    10

    4.0

    20 40

    DISTANCE: SENSOR TO OBJECT (IN)

    D:S=10:1

    SPOTDIA.*

    (MM)

    SPOTDIA.*

    (IN)

    DISTANCE: SENSOR TO OBJECT (MM)

    *FOCUS POINT D:S = 10:1 FAR FIELD D:S = 10:1

    0.4

    500250100

    25

    50

    1.0

    2.0

    104

    22

    59

    DISTANCE: SENSOR TO OBJECT (IN)

    D:S=40:1

    SPOTDIA.*

    (MM)

    SPOTDIA.*

    (IN)

    DISTANCE: SENSOR TO OBJECT (MM)

    *FOCUS POINT D:S = 40:1 FAR FIELD D:S = 40:1

    0.9

    15001000500

    28

    44

    1.1

    1.7

    4020

    18

    Product Specification

    Product Specification

    Optical Field of View

    Optical Field of View

    Dimension

    Dimension

    Code Number 6-IRman---

    Code Number 10-IRman---

    6-IRman

    10-IRman

    Non-contact infrared thermometer

    Non-contact infrared thermometer

    Installation-Type Infrared Thermometer

  • 8/13/2019 Catalog English 2012

    7/23

    07

    Segment IR-80-H

    Range 500~1700

    Resolution 0.1Emissivity 0.1~0.99

    Response Time Within 0.2 sec.

    Accuracy 2 or1%

    Field of View (D:S) 80:1

    Wavelength Range 1~1.7

    Input Power 12V~24V

    External Material Aluminum

    Cable Length 3M

    Range 0~400

    Wavelenght Range 8~14

    Accuracy 2 or 2% of measured value

    Input Power 12V~24V

    Model Description

    Code A Temperature range

    1 350~650

    2 500~1700

    Z Other

    Code B output

    M DC 0~20mA

    N DC 4-20mA

    V Voltage output DC 1~5V

    Z Other

    CODE C Cable length

    1 3M

    Z Other

    Product Specification

    Product Specification

    Optical Field of View Dimension

    Code Number IR-80-H---

    IR-80-H

    Ascon Infrared Thermometer

    Infrared Thermometer Accessorces

    Non-contact infrared thermometer

    Installation-Type Infrared Thermometer

    Airpurge Water-cooling jacket Bracket RS485 to RS232 Converter

    Real-time in the Computer Real-time data storage oftemperature

    2000

    25

    6

    1.0

    59 79

    DISTANCE: SENSOR TO OBJECT (IN)

    D:S=80:1

    SPOTDIA.*

    (MM)

    SPOTDIA.*

    (IN)

    DISTANCE: SENSOR TO OBJECT (MM)

    *FOCUS POINT D:S = 80:1 FAR FIELD D:S = 80:1

    0.2

    15001000500

    13

    19

    0.5

    0.7

    4020

  • 8/13/2019 Catalog English 2012

    8/23

    08

    Segment PIR550

    Range -60~550

    Wavelength Range 8~14

    Operating Temperature 0~50

    Accuracy 2 or 2% of measured value

    Emissivity 0.1~1.0

    Response Time within 1 Sec.

    Field of View (D:S) 12:1

    Battery life min 14 hours continuous use

    Dimensions 143.9*116.73*42.78mm

    Weight 180g(including battery)

    Segment PIR1500

    Range -35~1500

    Wavelength Range 8~14

    Operating Temperature 0~50

    Accuracy 2 or 2% of measured value

    Emissivity 0.1~1.0

    Response Time within 1 Sec.

    Field of View (D:S) 75:1

    MemoryDetailed 24 Memories withTemperature & Emissivity

    Dimensions 143.9*116.73*42.78mm

    Battery lifemin 14 hours continuous use

    (without Laser and Back Light)

    Dimensions 204.14*179.19*58.40mm

    Weight 355g(including battery)

    Segment PIR2400

    Range 200~2400

    Wavelength Range 1~2

    Operating Temperature 0~50

    Accuracy 2 or 2% of measured value

    Emissivity 0.1~1.0

    Response Time within 1 Sec.

    Field of View (D:S) 100:1

    MemoryDetailed 24 Memories withTemperature & Emissivity

    Dimensions 143.9*116.73*42.78mm

    Battery lifemin 14 hours continuous use

    (without Laser and Back Light)

    Dimensions 233.8*207,5*60.6mm

    Weight 550g(including battery)

    Product Specification

    Product Specification

    Product Specification

    PIR550

    PIR1500

    PIR2400

    Portable Infrared Thermometer

    Portable Infrared Thermometer

    Portable Infrared Thermometer

    Portable Infrared Thermometer

  • 8/13/2019 Catalog English 2012

    9/23

    09

    Product Specification

    Product Specification

    DI-20 Series

    DA-91 Series

    Multi Input Indicator-compact type

    Audiovisual displayGas Detecter

    Installation-Type Gas Detecter

    Segment DI-20

    Input Type

    (User-Selectable Multiple Input)

    TC (B, R, S, K, E, J, T, N), RTD (DIN PT1, DIN PT(0.1), JIS PT)

    DC (mV, V, mA)Accuracy 0.2% / Output Signal: 0.25% (Full scale)

    Dimensions and Display Cycle 100 ms (mV, Volt, mA type), 200 ms (TC, TRD type)

    Input Resistance Volt type is 400 , mA type is 250 , 1 is for other types

    Signal Source Resistance PT100 , 30 /Line, Other types 300 / Line

    NMRR / CMRR More than 50 dB / More than 140 dB

    Alarm (Option)Channels : 2 or 4 alarms, Contact point : 1a (Normal, Open)Contact capacity : AC 250 V / 5 A, DC 30 V / 5 A

    Communication Specification(Option)

    Kind : RS232, RS422, RS485, ID (Address) setup : 1 ~ 127Signaling speed : 4800 bps ~ 57600 bps

    Output Signal (Option) Electrical insulation Current : DC4 ~ 20 mA / 600

    Use EnvironmentStorage Temperature/Humidity : -20 ~70 / 5%~95%Operating Temperature/Humidity : -5 ~60 / 10%~90%

    Power Consumption 3.5 W (Max.)

    Input Power AC 85 V ~ 264 V

    Insulation resistance FG input, FG power, power input, More than 100 (500 VDC)

    Built-in Sensor Power DC 24 V / 30 mA / less than 0.5 %

    Weight About 450 g

    Size (mm) 96 (W) x 48 (H) x 100 (D) mm

    Installation Method Panel-mounting type

    Segment DA-91

    Detection target gas oxygen, nitrogen and toxic gas

    Detection principle Electro-Chemical, or NDIR

    Response time within 10 Sec, 90%/Full Scale

    Accuracy 3%/Full Scale

    Input power AC 220V/60Hz

    External output 4~20mA, 2stage(AL1/AL2) Alarm RELAY CONTACT, RS-485(Option)

    Alarm display

    Low Alarm - AL1 LED(RED)

    High Alarm - AL2 LED(RED)

    Sight-mars light display - BZ LED(RED)

    Alarm typemars light off

    hearing - buzzer(90/1m)

    Operating Tompereture /Humidity

    -20~50, 5~95% RH (Non-Condensing)

    Alarm off Manual, Automatic return

    Installation Method Wall Mounting Type

    Measuring range 0 ~ 10,000 ppmDimension

  • 8/13/2019 Catalog English 2012

    10/23

    10

    Segment DA-500

    Detection PrincipleCatalytic combustion, Non-dispersive infrared

    (NDIR), TCD, Electro-chemical

    Detection Method Diffusion type

    Target Gas Combustible gas, Toxic gas

    Detection Range 0 ~ 100% LEL, 0 ~ 10,000 PPM, 0 ~ 100% VOL

    Response Time Within 30 sec. 90% / Full scale

    Accuracy 3% / Full scale

    Display Back light LCD (2 Lines 8 Characters)

    Checking Function Sensor fault indication on LCD (SEN -err), 2 Output

    Select ion Function Calibration concentration, Detection range setting

    Input Power DC 20 V ~ 30 V

    External Output 4 mA ~ 20 mA / Full scale - 2.5 Km Transmission

    OperatingTemperature/Humidity

    -20 ~ 60 , 5 ~ 95% RH (Non-condensing)

    Signal Cable CVVS & CVVSB 1.25 sq x 3Wire shielded type

    Cable Conduit 1/2 or 3/4 PF, NPT

    Installation Method Wall or Pipe station

    External Material Cast aluminum alloy

    Explosion-ProofApproval

    Ex d IIC T5 KGS

    Relay contacts Two step- Relay Contact (High/Low)

    Segment DA-100

    Detection Principle Catalytic combustion, TCD, Electro-chemical

    Detection Method Diffusion type

    Target Gas Combustible gas, Toxic gas

    Detection Range 0 ~ 100% LEL, 0 ~ 10,000 PPM, 0 ~ 100% VOL

    Response Time Within 10 sec, 90% / Full scale

    Accuracy 3% / Full scale

    Checking Function Sensor fault indication on FND (S.Er), 2 Output

    Input Power DC 20 V ~ 30 V

    External Output 4 mA ~ 20 mA / Full scale - 2.5 Km Transmission

    OperatingTemperature/

    Humidity-20 ~ 60 , 5% ~ 95% RH (Non-condensing)

    Signal Cable CVVS & CVVSB 1.25 sq x 3 Wire-shield type

    Cable Conduit 1/2 or 3/4 PF, NPT

    Installation Method Wall or Pipe station

    External Material Cast aluminum alloy

    Explosion-ProofApproval

    Ex d IIC T5 -KGS

    H2

    0 %LEL

    w

    g

    R

    ww.

    A

    00.01

    -

    S

    a.c4v

    2r

    o

    D -DA SN m

    -1 MOEDLAD

    O

    ap

    TE

    2-H/G

    ET

    CD

    M

    nesdw

    o

    E

    G

    01

    T

    XD

    I

    I

    C

    5

    X0E

    Product Specification

    Product Specification

    Dimension

    Dimension

    DA-500

    DA-100

    SMART Gas detector

    SMART Gas detector-Indicator type DA-500. Series

    SMART Gas detector - Non-indicator typeDA-100. Series

  • 8/13/2019 Catalog English 2012

    11/23

    11

    Segment DA-800

    Detection Principle Catalytic combustion, TCD, NDIR, Electro-chemical

    Detection Method Suction type

    Target Gas Combustible gas, Toxic gas

    Detection Range 0 ~ 100% LEL, 0 ~ 100% VOL, 0 ~ 10,000 PPM

    Response Time Within 10 sec, 90% / Full scale

    Accuracy 3% / Full scale

    Induced Vacuum Flow 1.5 l/min ~ 2.5 l/min

    Selection Function Calibration concentration, Detection-range setting

    Input Power DC 20 V ~ 30 V

    External Output 4 mA ~ 20 mA / Full scale - 2.5 Km Transmission

    Operating Temperature/Humidity

    -20 ~ 60 , 5% ~ 95% RH (Non-condensing)

    Signal Cable CVVS & CVVSB 1.25 sq x 3 Wire shielded type

    Cable Conduit 1/2 or 3/4 PF, NPT

    Suction Line ConduitPipe

    1/4 Tube

    Installation Method Wall mounting

    External Material Cast aluminum alloy

    Explosion-ProofApproval

    Ex d IIB+H2 T6- Korea Testing Laboratory (KTL)

    Output Options 2 Step Relay-Contact (High/Low), RS-485

    Segment DA-750

    Detection PrincipleCatalytic, Electro-chemical, Non-dispersive infrared

    (NDIR), Photo-ionization (PID)

    Detection Method Suction type

    Input Power 20 V ~ 30 V (24 V DC Normal) / 250 mA (Max.)

    Induced Vacuum Flow 100 cc ~ 2.0 l/min

    Accuracy 3% Full scale

    External Output 4 mA ~ 20 mA DC, RS-485

    Gas Leak Data Storage Gas leak records: 4,000

    DisplayGraphic LCD (128 dots*64 dots) Korean/English

    PPM, % LEL, %VOL(Adjustable by user programming)

    Operating Display 4 LEDs (Power, 2 Alarms, 1 Trouble)

    Alarm Value Setting AL1, AL2 2 Stage(Adjustable by user programming by user)

    Alarm Delay Time 0 sec ~ 99 sec(Adjustable by user programming by user)

    Relay Outputs 125 V 0.6A / 3 SPST Relay-Contact(2 Alarm, 1 Trouble)

    Operating Temperature/Humidity -20 ~ 60, 5% ~ 95% RH (Non-condensing)

    Installation Method Wall mounting

    Signal Cable CVVS & CVVSB 1.25 sq x 3 wire shielded type

    Gas Flow Distance Less than 100 m

    Gas Inlet Tube 6 Tube

    NH3 PPM

    10.0 F

    L

    O

    W

    P OW ER F AU LT A L1 A L2

    UP

    RESET MODE

    D OW N E NT

    TEST

    U P D OW M

    MOTOR

    Product Specification

    Product Specification

    Dimension

    Dimension

    DA-800

    DA-750

    SMART Gas detector

    SMART Gas detector-Suction typeDA-800. Series

    SMART Gas detector-Suction typeDA-750. Series

  • 8/13/2019 Catalog English 2012

    12/23

    12

    Segment DA-50

    Detection PrincipleCatalytic, Electrochemical, Non-dispersive infrared

    (NDIR), Photo-ionization (PID)

    Detection Method Diffusion type

    Input Power 20 V ~ 30 V (24 V DC Normal) / 100 mA (Max.)

    Accuracy 3% Full scale

    External Output 4 mA ~ 20 mA, 2 Step Relay (AL1, AL2) RS-485

    Display LCD(8Characters*2Line) With Back-light %,PPM,PPb

    Operating Display 4 LEDs (Power, 2 Alarms, 2 RS485 TX, RX)

    Relay Outputs 125 V 0.6 A / 2-SPST Relay-Contact (2 Alarms)

    Target Gas Toxic gas (Refer to detection target toxic gas list)

    Installation Method Wall mounting

    Signal Cable Cvvs &Cvvsb 1.25 sq *3Wire shielded type

    OperatingTemperature / Humidity

    -20 ~ 60 , 5% ~ 95% RH (Non-condensing)RESET MO DE U P D OW N ENT

    POW AL 1 A L2 R X TX

    GAS DETECTOR

    M/G

    OUT

    DC 24V

    4-20mA

    MODEL: DA-50

    GASDNA CO.,LTD

    POW

    NH

    OPPM

    3

    Product Specification

    Product Specification

    Dimension

    DA-50

    SMART Gas detector

    Radio Environment Air Quality Monitor

    SMART Gas detectorDA-50. Series

    IAQ-700This equipment measures indoor air quality and is displayed by the number,Especially CO2, Temperature, Humidity, VOC, Dust etc,) and can be easilyinstalled indoor.

    Rating CO2

    Input PowerDimensions

    DC 9V~24V310*157*60

    Detection MethodDetection RangeResponse TimeOperating Temperature/Humidity

    Temperature Humidity

    RangeResolutionRepeatabilityResponse Time

    -25 ~ +600.1E0.1(Min)5 ~ (Max)30sec

    RangeResolutionRepeatabilityResponse TimeNonlinearity Raw data

    0~100%RH1%RHE0.1%RH1/e(63%)slowly moving airE3%RH Nonlinearity

  • 8/13/2019 Catalog English 2012

    13/23

    13

    Segment SD - 110

    General Form 1 or, 2 Channel Monitoring

    Product Type Wall-mounting type

    Detection Principle Ionizations Smoke Chamber

    Detection Method Diffusion type

    Response Time Within 3 min.

    Detection Range 0 ~ 500 Pcs/L

    External Output 4 ~ 20

    Input Power DC 24V

    Alarm Type High / Low 2 Step Alarm (user-setup)

    Alarm off-type Manual or Automatic (user-selection)

    Signal Cable CVVS & CVVSB 1.25sq x 3 Wire - Shield Type

    Operating Current 500. Maximum

    System InitializationTime

    Within 50 min

    External Structure Monitoring Unit - Metal, Sensor Unit - Aluminum

    Operating Temperature/Humidity

    -20~ 50 / 0 ~ 95% RH (Non-Condensing)

    Process-Type Digital Process

    SD - 110

    Smoke Detector

    Gas D&A CO.

    Product Specification

    Dimension

    NH3,CH4,CO2-Laser GAs Monitor

    Smoke Sensor SD-110

    LGD F200

    System specifications

    Dimensionscell layout

    Integrated flow-throughcell

    Cell temperature Ambient(A)/Heated(H) Up to 190

    Dimensions range ppm or %

    Typical dynamicrange

    2000Range extension possibleupon request

    Electrical Feature

    Power supply 10~30V DC

    Power Consumption of detector 2W

    Optional cel l heater powerconsumption(H)

    Up to 100W For heating up to 190

    Data out Digital:Rs232 Analog:4-20mA or0-5V

  • 8/13/2019 Catalog English 2012

    14/23

    14

    Segment SD - 50

    Detection Principle Ionization smoke chamber

    Detection Method Diffusion type

    Response Time Within 3 sec.

    External Output A contact (DC 30 V 1 A), B contact

    Input Power DC 22 V ~ 26 V

    Operating Current 25 (max.)

    External Material Acetal

    Operating Temperature/Humidity

    -20 ~ 65 / 0 ~ 95% RH (Non-condensing)

    Product Specification

    Dimension

    Dimension

    Smoke Sensor

    Single-type Gas detector Receiving unit GMS-1000

    SD-50

    Segment GMS - 1000

    Structure Single type / 1 Circuit

    Input Power AC 230 V / 60 Hz

    Input Signal 4 ~ 20 DC / Full scale

    Output Power DC 24 V (250 )

    Output Signal 4 ~ 20 DC / Full scale

    Signal Resolution A/D Converter 20000, D/A Converter 12 Bit

    Display % LEL (Combustible), % (Oxygen), PPM (Toxic)

    Alarm DisplayLow alarm AL1 LED (Red)High alarm AL2 LED (Red)

    Fault alarm Fault LED (Yellow)

    Alarm TypeVisual : LED flickering

    Auditory : Buzzer sound (More than 80 )

    Alarm DensityAL1 / AL2 2 Level alarm density

    (Adjustable by user programming by user)

    Alarm Delay Time0 sec ~ 99 sec

    (Adjustable by user programming by user)

    Alarm Off Manual , Automatic return

    Alarm Output 2 Level (AL1 / AL2) Relay-Contact

    OperatingTemperature

    -20 ~ 70

    Operating Humidity 5 % ~ 95 % RH (Non-condensing)

    External Material Poly Carbonate (PC)

    Installation Method Wall mounting

    Product Specification

  • 8/13/2019 Catalog English 2012

    15/23

    15

    SegmentGMS - 2000

    Power & Alarm Unit Receiving Unit

    Control Structure Alarm unit : Receiving unit = 1:1 - 64 Receiving unit : detector = 1:1

    Extension Structure Slide Card Type

    Input Power AC 230V / 60Hz

    Output Power DC 24V(250)

    Input Signal 4 ~ 20 DC/F.S

    Output Signal 4 ~ 20 DC/F.S , RS-485(Option)

    Display % LEL (Combustible), % (Oxygen), PPM (Toxic)

    Power Display Power LED (Green)

    Alarm DisplayAlarm LED (Red)

    Alarm LED flickering

    Low alarm AL1 LED (Red)High alarm AL2 LED (Red)

    Fault alarm - Fault LED (Yellow)

    Alarm Type Buzzer sound (More than 80 )Visual : Applicable alarm LED

    Flickering

    Alarm DensityHigh / Low - 2Level alarm density(Adjustable by user programming

    by user)

    Alarm Delay Time0 sec ~ 99 sec (Adjustable by

    user programming by user)

    Alarm Off Manual, Automatic return

    Alarm Output SPST Relay output for High / Low 2Level alarmSPST Relay output for Fault alarm

    OperatingTemperature /

    Humidity-20 ~ 60, 5 ~ 95%RH (Non-Condensing)

    External Material 19 (3U) Unit : Al uminum / System enclosure : Metal case

    Output Options RS-485

    GAS ALARM CONTROL SYSTEM

    ()

    Product Specification

    Product Specification

    Dimension

    Dimension

    4-Channel Gas detector Receiving unit

    Multiple type Gas detector Receiving unit GMS-2000

    GMS-1500

    Segment GMS - 1500

    Structure Multiple-type (4 Connection detectors) / 4 Circuits

    Input Power AC 220 V / 60 Hz, AC 110 V / 60 Hz (Option)Input Signal 4 Channels (4 ~ 20 / FS)

    Output Power DC 24 V (250 )

    Output Signal 4 Channels (4 ~ 20 / FS)

    DisplayLCD Display PPM, % LEL, %, PPB

    (Adjustable by user programming by user)

    Alarm DisplayLow alarm AL1 LED (Red)High alarm AL2 LED (Red)

    Fault alarm Fault LED (Yellow)

    Alarm TypeVisual : LED Flickering

    Auditory : Buzzer sound (More than 80 )

    Alarm Value SettingAL1/AL2 2 Level alarm

    (Adjustable by user programming by user)

    Alarm Delay Time

    0 sec ~ 99 sec

    (Adjustable by user programming by user)

    Alarm Off Manual, Automatic return

    Alarm Output 250 V 5 A / 11-SPST Relay-Contact (10 Alarms, 1 Fault)

    OperatingTemperature

    -20 ~ 70

    Operating Humidity 5 % ~ 95 % RH (Non-condensing)

    External Material Poly Carbonate (PC)

    Installation Method Wall mounting

  • 8/13/2019 Catalog English 2012

    16/23

    SYSTEMCONFIGURATION

    DC 4-20mA

    RS-485

    RS-232/RS-485

    DA-800

    DA-50 SD-50 CD-10 CD-30

    GMS-1000

    DA-750 GMS-1500

    DA-500 GMS-2000

    DA-100 PLC

    CONVERTER

  • 8/13/2019 Catalog English 2012

    17/23

    SYSTEMCONFIGURATION

    Displaying real-timetemperature, on/off relay,& alarm

    GO/NO GO signal

    Signal to measure temperature

    RS-485

    IR-80 Non-contact infrared thermometer

    DA-90 Site displaying unit Data collection and monitoring unit

    TCP/IP communication(real-time temperature data transfer)

    Robot

    Coil spring

    Main process control system

    Producing quality controlchart Recording and reportingdata, trend of temperature,& alarm which can beconverted into excel format

    Alarming low & hightemperature

  • 8/13/2019 Catalog English 2012

    18/23

    Customers

    Steel

    Glass

    Tire

    Plastic

    Other

    Automotive

    Paper

    Semiconductor

    Cement

    Power station

    Food

  • 8/13/2019 Catalog English 2012

    19/23

    Metal Processing

    1205

    Result inIncreased productivityReduced energy costHigher qualityReduced downtimeEasy data recordingEnhanced worker safety

    Continuous CasterIR-80 Non-contactinfrared thermometerfor targets in steamy/dusty environment

    Hot Rolling millIR-80 Non-contact infraredthermometer for targets obscuredby airborne contaminants

    Cold MillIR-40 Non-contact infraredthermometer for spotdimensions

    Rod/Wire MillIR-80 Non-contact infraredthermometer for dusty and steamyenvironments, for fast moving targets,for targets smaller than field of view

    Reheater Interior-Ambient Temperature compensation-Real-time temperature trending

    Reheat FurnaceIR-80 Non-contact infraredthermometer for targets in steamy/dusty environment

    IR-80 Non-contact infraredthermometer IR-80 Non-contact infrared

    thermometer

    PC monitoring and data collection unit

    IR-80 Non-contactinfrared thermometer(enclosed in coolingJacket)

    IR-80 Non-contact infraredthermometer (mounted inCooling Jacket) checkingbillet exit temperature

    RoughingStands

    PinchRolls

    FinishingStands

    Water Box(controlled cooling)

    IR-80 Non-contactinfrared thermometer

    IR-80 Non-contactinfrared thermometer

    IR-80 Non-contactinfraredthermometer

    Blast Gate

    Senser

    ScaleBreaker

    RoughingStands

    Shear FinishingStands

    Cooling DownCoiler

    Senser

    Senser

    Senser

    Direction

    Uncoiler RecoilerFinishing Stands

    Senser

    SenserSenser

    Senser Senser

    Closed-end CeramicSighting Tube

    Reheat Furnace Interior

    Thermocouple

  • 8/13/2019 Catalog English 2012

    20/23

    Glass Processing

    Crwon

    Feed Hopper

    Regenerator(Cross-fired)

    Sensor inside ThermoJacketmeasures molten glass in canalfor proper furnace exit temperature IR-80 Non-contact infrared

    thermometer

    FromfurnaceFromfurnace Forehearth

    Gob

    Automated glass containerForming machine

    Annealing Lehr Cold end surfacetreatment area

    To sorting, packaging,and shipping

    IR-80 or IR-40 Non-contactinfrared thermometerIR-80 Non-

    contact infraredthermometer

    Canal

    Tomanufacturing

    Portable sensors measureexterior for hot spot detection(deteriorating refractory material)

    Melt Furnace

    Flat glass

    Glass fiber Automotive windshield

    Bottles and containers

    Sensors mounted insideThermoHackets measure packingmaterial temperature for optimumregenerator airflow control

    IR-80 Non-contact infrared thermometermonitor exit temperatures

    Air-cooled fixed sensors mounted over Tin Bath and Lehr makesure zone temperatures are correct

    Molten glassfrom furnace

    To cutters and stackers

    Tin Bath1. Heater zone

    2. Fire polish zone3. Cooling zone

    Portable sensors help maintain tanksand mechanical parts

    IR-80 or IR-40 Non-contactinfrared thermometer

    IR-80 or IR-40 Non-contactinfrared thermometer

    IR-80 or IR-40 Non-contactinfrared thermometer

    Flat Glassfrom Stock

    Heating Section

    Forming Section

    To Cooling Section

    IR-80 Non-contact infraredthermometer monitor heater exit tocheck flat glass temperatures beforeentering forming section.

    IR-80 Non-contactinfrared thermometerconnector to computerscan automatically adjustthe cooling process.

    Fromfurnace

    To cuttingand packaging

    CuringovenConveyor belt

    Forehearth

    Spinners

    Annealing LehrControlled cooling in 4 to 8 separate zones

  • 8/13/2019 Catalog English 2012

    21/23

  • 8/13/2019 Catalog English 2012

    22/23

    Paper

    Automotive

    Busbar temperature monitoring

    Process automation system

    OVEN DRYER

    DIE

    COOLING

  • 8/13/2019 Catalog English 2012

    23/23