Catalog DDG-Components 2013 (v 8 2013)

162
www.ddg-scanlab.com Catalog 2013 DDG-Components HQ Implant Components

description

HQ Implants Parts.

Transcript of Catalog DDG-Components 2013 (v 8 2013)

Page 1: Catalog DDG-Components 2013 (v 8 2013)

www.ddg-scanlab.com

Catalog 2013

DDG-ComponentsHQ Implant Components

Page 2: Catalog DDG-Components 2013 (v 8 2013)
Page 3: Catalog DDG-Components 2013 (v 8 2013)

Nobel Biocare® Replace Select® DDG-1100 Pag

Np DDG-1101 11-13

Rp DDG-1102 15-17

Wp DDG-1103 19-21

AstraTech® Osseospeed® DDG-1200

3.0 DDG-1201 23

3.5/4.0 DDG-1202 25-27

4.5/5.0 DDG-1203 29-31

Conic 20º DDG-1204 25-31

Conic 45º DDG-1205 25-31

Klockner® Essential® DDG-1300

4.5 DDG-1301 33

6.0 DDG-1302 35

Nobel Biocare® Bränemark® DDG-2100

Np DDG-2101 37

Rp DDG-2102 39-41

Wp DDG-2103 43

Dentsply® Friadent Xive® DDG-2200

3.4 DDG-2201 45

3.8 DDG-2202 47

4.5 DDG-2203 49

5.5 DDG-2204 51

BTI® Internal® DDG-2300

4.1 DDG-2301 53

5.5 DDG-2302 55

Nobel Biocare® Active® DDG-3100

Np DDG-3101 57

Rp DDG-3102 59

DDG-ComponentsHQ Implant Components

Index

Page 4: Catalog DDG-Components 2013 (v 8 2013)
Page 5: Catalog DDG-Components 2013 (v 8 2013)

Zimmer® Tapered Screw Vent® DDG-3200 Pag

3.7 DDG-3201 63-65

4.5 DDG-3202 65

5.7 DDG-3203 67

Biocomp® DDG-3300

DDG-3301 69

DDG-3302 71

Nobel Biocare® MultiUnit® DDG-4100

Rp DDG-4101 73

Wp DDG-4102 75

BTI EXTERNAL® DDG-4200

3.5 DDG-4201 77

4.1 DDG-4202 79-81

5.5 DDG-4203 83

Microdent® DDG-4300

3.5 DDG-4301 85

4.2 DDG-4301 87

5.1 DDG-4301 89

Biomet 3i® Certain® DDG-5100

3.4 DDG-5101 91-93

4.1 DDG-5102 95-97

5.0 DDG-5103 99-101

Klockner® SK2® DDG-5200

4.3 DDG-5201 103

Osstem® GS System® DDG-5300

Mini DDG-5301 105

Regular DDG-5302 107

DDG-ComponentsHQ Implant Components

Index

Page 6: Catalog DDG-Components 2013 (v 8 2013)
Page 7: Catalog DDG-Components 2013 (v 8 2013)

Biomet 3i® Osseotite® DDG-6100 Pag

3.4 DDG-6101 109

4.1 DDG-6102 111-113

5.0 DDG-6103 115

Implant Direct® Bar abutment® DDG-6200

4.2 DDG-6201 117

Straumann® Tissue Level® DDG-7100

3.5 DDG-7101 119

4.8 Implant Level DDG-7102 121-123

4.8 SynOcta DDG-7103 125

6.0 DDG-7104 127

6.0 SynOcta DDG-7105 129

Camlog® Screw Line® DDG-7200

3.3 DDG-7201 131

3.8 DDG-7202 133

4.3 DDG-7203 135

5.0 DDG-7204 137

6.0 DDG-7205 139

Bar Abutment DDG-7206 141

Straumann® Bone Level® DDG-8100

3.3 DDG-8101 143

4.1 DDG-8102 145-147

Dentsply Friadent® Ankylos® DDG-8200

Implant Level Non Engaging DDG-8201 149

Abutment Level DDG-8202 151

DDG-ComponentsHQ Implant Components

Index

Page 8: Catalog DDG-Components 2013 (v 8 2013)
Page 9: Catalog DDG-Components 2013 (v 8 2013)

DDG-ComponentsHQ Implant Components

Biohorizons® Internal® DDG-9100 Pag

3.5 DDG-9101 153

4.5 DDG-9102 155

5.7 DDG-9103 157

Osstem® TS System® DDG-9200

Mini DDG-9201 159

Regular DDG-9202 161

Index

Page 10: Catalog DDG-Components 2013 (v 8 2013)

Nobel Biocare Replace Select® 3.5 (Ref.DDG-1101) Part. 1

DDG-1100 System

Page 11: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

11www.ddg-scanlab.com

Analog

Straight Zrabutment 1 mm

Screw

Engagingcastable abutment

Titanium engagingInterface

Titanium Impressioncoping Open Tray

Non Engagingcastable abutment

Straight Zrabutment 2 mm

Titanium Healingabutment

Straight titanium abutment

Titanium Non engaging Interface

Titanium Impressioncoping ClosedTray

Ref. DDG-110101

Ref. DDG-110125

Ref. DDG-110180

Ref. DDG-110111

Ref. DDG-110131

Ref. DDG-110170

Ref. DDG-110110

Ref. DDG-110126

Ref. DDG-110151

Ref. DDG-110121

Ref. DDG-110130

Ref. DDG-110171

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

• Implant Replica.• Exact.• For duplicate the shape and position of the implant platform.• Made in Stainless steel.

• For cemented resto-rations. Engaging.• Zirconium High Aesthetics.• With Titanium Interface. • High Precision. • High Strength.• Made in CIP zirconia. • Made in Titanium 5 grade.• Interfaces Anodized.

• For fixation of the restoration. • High Quality.• High Strength.• Made in titanium 5 grade.

• Cast component.• Engaging. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

•For screw-cement reteined restorations. • Engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

• Used to mark the placement of a implant in an impression.• Open Tray.• Engaging.• High Quality.• Made in Titanium 5 grade.

• Cast component.• Non engaging. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

• For cemented resto-rations. Engaging.• Zirconium High Aesthetics.• With Titanium Interface. • High Precision. • High Strength.• Made in CIP zirconia. • Made in Titanium 5 grade.• Interfaces Anodized.

•for allow gingival tisseus to heal prior to the placement abutment and maintain proper spacing in the oral cavity. • DDG-110151-3mm• DDG-110152-5mm• DDG-110153-7mm• Made in Titanium 5 grade.

• Used for bridge abut-ment and crown.• Engaging.• High Quality.• High Strength.• Made in titanium 5 grade.

•For screw-cement reteined restorations. • Non engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

• Used to mark the placement of a implant in an impression.• Closed Tray.• Engaging.• High Quality.• Made in Titanium 5 grade.

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

Page 12: Catalog DDG-Components 2013 (v 8 2013)

Nobel Biocare Replace Select® 3.5 (Ref.DDG-1101) Part. 2

DDG-1100 System

Page 13: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

13www.ddg-scanlab.com

Scanbody InterfacesNon engaging

Scanbody InterfacesEngaging (IntraOral)

ScanBody DirectEngaging

Ref. DDG-110140Ref. DDG-110141 Ref. DDG-110143

Technical SpecificationsTechnical Specifications Technical Specifications

• For scan Implant position. • Non engaging.• High Accuracy• For use in Laboratory and IntraOral.• Implant Level• Compatible for all Cad system.• Not necessary spray.(90% of cases).

• For scan Implant position. • Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

• For scan Implant position. • High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

Page 14: Catalog DDG-Components 2013 (v 8 2013)

Nobel Biocare Replace Select® 4.3 (Ref.DDG-1102) Part. 1

DDG-1100 System

Page 15: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

15www.ddg-scanlab.com

Analog

Straight Zrabutment 1 mm

Screw

Engagingcastable abutment

Titanium engagingInterface

Titanium Impressioncoping Open Tray

Non Engagingcastable abutment

Straight Zrabutment 2 mm

Titanium Healingabutment

Straight titanium abutment

Titanium Non engaging Interface

Titanium Impressioncoping ClosedTray

Ref. DDG-110201

Ref. DDG-110225

Ref. DDG-110280

Ref. DDG-110211

Ref. DDG-110231

Ref. DDG-110270

Ref. DDG-110210

Ref. DDG-110226

Ref. DDG-110251

Ref. DDG-110221

Ref. DDG-110230

Ref. DDG-110271

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

• Implant Replica.• Exact.• For duplicate the shape and position of the implant platform.• Made in Stainless steel.

• For cemented resto-rations. Engaging.• Zirconium High Aesthetics.• With Titanium Interface. • High Precision. • High Strength.• Made in CIP zirconia. • Made in Titanium 5 grade.• Interfaces Anodized.

• For fixation of the restoration. • High Quality.• High Strength.• Made in titanium 5 grade.

• Cast component.• Engaging. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

•For screw-cement reteined restorations. • Engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

• Used to mark the placement of a implant in an impression.• Open Tray.• Engaging.• High Quality.• Made in Titanium 5 grade.

• Cast component.• Non engaging. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

• For cemented resto-rations. Engaging.• Zirconium High Aesthetics.• With Titanium Interface. • High Precision. • High Strength.• Made in CIP zirconia. • Made in Titanium 5 grade.• Interfaces Anodized.

•for allow gingival tisseus to heal prior to the placement abutment and maintain proper spacing in the oral cavity. • DDG-110251-3mm• DDG-110252-5mm• Made in Titanium 5 grade.

• Used for bridge abut-ment and crown.• Engaging.• High Quality.• High Strength.• Made in titanium 5 grade.

•For screw-cement reteined restorations. • Non engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

• Used to mark the placement of a implant in an impression.• Closed Tray.• Engaging.• High Quality.• Made in Titanium 5 grade.

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

Page 16: Catalog DDG-Components 2013 (v 8 2013)

Nobel Biocare Replace Select® 4.3 (Ref.DDG-1102) Part. 2

DDG-1100 System

Page 17: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

17www.ddg-scanlab.com

Scanbody InterfacesNon engaging

Scanbody InterfacesEngaging (IntraOral)

ScanBody DirectEngaging

Ref. DDG-110240Ref. DDG-110241 Ref. DDG-110243

Technical SpecificationsTechnical Specifications Technical Specifications

• For scan Implant position. • Non engaging.• High Accuracy• For use in Laboratory and IntraOral.• Implant Level• Compatible for all Cad system.• Not necessary spray.(90% of cases).

• For scan Implant position. • Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

• For scan Implant position. • High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

Page 18: Catalog DDG-Components 2013 (v 8 2013)

Nobel Biocare Replace Select® 5.0 (Ref.DDG-1103) Part. 1

DDG-1100 System

Page 19: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

19www.ddg-scanlab.com

Analog

Straight Zrabutment 1 mm

Screw

Engagingcastable abutment

Titanium engagingInterface

Titanium Impressioncoping Open Tray

Non Engagingcastable abutment

Straight Zrabutment 2 mm

Titanium Healingabutment

Straight titanium abutment

Titanium Non engaging Interface

Titanium Impressioncoping ClosedTray

Ref. DDG-110301

Ref. DDG-110325

Ref. DDG-110380

Ref. DDG-110311

Ref. DDG-110331

Ref. DDG-110370

Ref. DDG-110310

Ref. DDG-110326

Ref. DDG-110351

Ref. DDG-110321

Ref. DDG-110330

Ref. DDG-110371

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

• Implant Replica.• Exact.• For duplicate the shape and position of the implant platform.• Made in Stainless steel.

• For cemented resto-rations. Engaging.• Zirconium High Aesthetics.• With Titanium Interface. • High Precision. • High Strength.• Made in CIP zirconia. • Made in Titanium 5 grade.• Interfaces Anodized.

• For fixation of the restoration. • High Quality.• High Strength.• Made in titanium 5 grade.

• Cast component.• Engaging. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

•For screw-cement reteined restorations. • Engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

• Used to mark the placement of a implant in an impression.• Open Tray.• Engaging.• High Quality.• Made in Titanium 5 grade.

• Cast component.• Non engaging. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

• For cemented resto-rations. Engaging.• Zirconium High Aesthetics.• With Titanium Interface. • High Precision. • High Strength.• Made in CIP zirconia. • Made in Titanium 5 grade.• Interfaces Anodized.

•for allow gingival tisseus to heal prior to the placement abutment and maintain proper spacing in the oral cavity. • DDG-110351-3mm• DDG-110352-5mm• Made in Titanium 5 grade.

• Used for bridge abut-ment and crown.• Engaging.• High Quality.• High Strength.• Made in titanium 5 grade.

•For screw-cement reteined restorations. • Non engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

• Used to mark the placement of a implant in an impression.• Closed Tray.• Engaging.• High Quality.• Made in Titanium 5 grade.

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

Page 20: Catalog DDG-Components 2013 (v 8 2013)

Nobel Biocare Replace Select® 5.0 (Ref.DDG-1103) Part. 2

DDG-1100 System

Page 21: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

21www.ddg-scanlab.com

Scanbody InterfacesNon engaging

Scanbody InterfacesEngaging (IntraOral)

ScanBody DirectEngaging

Ref. DDG-110340Ref. DDG-110341 Ref. DDG-110343

Technical SpecificationsTechnical Specifications Technical Specifications

• For scan Implant position. • Non engaging.• High Accuracy• For use in Laboratory and IntraOral.• Implant Level• Compatible for all Cad system.• Not necessary spray.(90% of cases).

• For scan Implant position. • Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

• For scan Implant position. • High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

Page 22: Catalog DDG-Components 2013 (v 8 2013)

AstraTech® Osseospeed Tx® 3.0 (Ref.DDG-1201)

DDG-1200 System

Page 23: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t sD D G - C o m p o n e n t s

23www.ddg-scanlab.com

Titanium engagingInterface

Screw

Engagingcastable abutment

Scanbody InterfacesNon engaging

Titanium Non engaging Interface

Scanbody InterfacesEngaging (IntraOral)

Screw

ScanBody DirectEngaging

Ref. DDG-120101

Ref. DDG-120125

Ref. DDG-120111

Ref. DDG-120131

Ref. DDG-120110

Ref. DDG-120126

Ref. DDG-120183

Ref. DDG-120130

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

•For screw-cement reteined restorations. • Engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade..

• For fixation of the restoration.• Normal type.. • High Quality.• High Strength.• Made in titanium 5 grade.• Nostius non tem per-timu.• Videorterur, nitus con-tilius • Hemore abenius, nius.

• For cemented resto-rations. Engaging.• Zirconium High Aesthetics.• With Titanium Interface. • High Precision. • High Strength.• Made in CIP zirconia. • Made in Titanium 5 grade.• Interfaces Anodized. .

• For scan Implant position. Titanium.• Non Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

•For screw-cement reteined restorations. • Non engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

• For scan Implant position. Titanium.• Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

• For cemented resto-rations. Engaging.• Zirconium High Aesthetics.• With Titanium Interface. • High Precision. • High Strength.• Made in CIP zirconia. • Made in Titanium 5 grade.• Interfaces Anodized.

• For scan Implant position. Titanium.• High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

Page 24: Catalog DDG-Components 2013 (v 8 2013)

AstraTech® Osseospeed Tx® 3.5/4.0 (Ref.DDG-1202) Part. 1

DDG-1200 System

Page 25: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

Scanbody InterfacesEngaging (IntraOral)

ScanBody DirectEngaging

Ref. DDG-120241

Technical Specifications

• For scan Implant position. Titanium.• Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

25www.ddg-scanlab.com

Analog

Straight Zrabutment 1 mm

Titanium HealingCap

Engagingcastable abutment

Titanium engagingInterface

Non Engagingcastable abutment

Straight Zrabutment 2 mm

Straight Titaniumabutment

Screw

Titanium Non engaging Interface

Ref. DDG-120201

Ref. DDG-120225

Ref. DDG-120250

Ref. DDG-120211

Ref. DDG-120231

Ref. DDG-120210

Ref. DDG-120226

Ref. DDG-120221

Ref. DDG-120220

Ref. DDG-120230

Ref. DDG-120240

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

• Implant Replica.• Exact.• For duplicate the shape and position of the implant platform.• Made in Stainless steel.

• For cemented resto-rations. Engaging.• Zirconium High Aesthetics.• With Titanium Interface. • High Precision. • High Strength.• Made in CIP zirconia. • Made in Titanium 5 grade.• Interfaces Anodized.

•for allow gingival tisseus to heal prior to the placement abutment and maintain proper spacing in the oral cavity. • DDG-120250-2mm• DDG-120252-4mm• DDG-120254-6mm• DDG-120256-8mm• DDG-120257-10mm• Made in Titanium 5 grade.

• Cast component.• Engaging. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

•For screw-cement reteined restorations. • Engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

• Cast component.• Non engaging. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

• For cemented resto-rations. Engaging.• Zirconium High Aesthetics.• With Titanium Interface. • High Precision. • High Strength.• Made in CIP zirconia. • Made in Titanium 5 grade.• Interfaces Anodized.

• Used for bridge abut-ment and crown.• Engaging.• High Quality.• High Strength.• Made in titanium 5 grade.

• For fixation of the restoration.• Normal type.. • High Quality.• High Strength.• Made in titanium 5 grade.

•For screw-cement reteined restorations. • Non engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

• For scan Implant position. Titanium.• Non Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

Scanbody InterfacesNon engaging

Page 26: Catalog DDG-Components 2013 (v 8 2013)

AstraTech® Osseospeed Tx® 3.5/4.0 (Ref.DDG-1202) Part. 2

DDG-1200 System

Page 27: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t sD D G - C o m p o n e n t s

27www.ddg-scanlab.com

AnalogConic 20º

ScanBody DirectEngaging Conic 20º

Non engagingcastable abutment 20º

Scanbody DirectNon engaging

Titaniumabutmant conic 20º

ScanBody DirectEngaging Conic 45º

Screwfor abutment 20º

ScanBody DirectEngaging

Ref. DDG-120202

Ref. DDG-120443

Ref. DDG-120218

Ref. DDG-120242

Ref. DDG-120206

Ref. DDG-120543

Ref. DDG-120221

Ref. DDG-120243

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

•For screw-cement reteined restorations. • Engaging• For Conic abutment 20º.• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade..

• For scan Implant position. Titanium.• For Conic abutment 20º. • High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.

• Cast component.• Engaging. • For create Bridge.• For Conic abutment 20º. • Cnc Machined.• Made in Delrin Plastic.

• For scan Implant position. Titanium.• Non Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

•For screw-reteined restorations. • Non engaging.• DDG-120206-0.5mm.• DDG-120207-1mm• DDG-120208-2mm• DDG-120209-4mm• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

• For scan Implant position. Titanium.• For Conic abutment 45º. • High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.

• For fixation of the restoration.• For Conic abutment 20º. • High Quality.• High Strength.• Made in titanium 5 grade.

• For scan Implant position. Titanium.• High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

Page 28: Catalog DDG-Components 2013 (v 8 2013)

AstraTech® Osseospeed Tx® 4.5/5.0 (Ref.DDG-1203) Part 1

DDG-1200 System

Page 29: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

Scanbody InterfacesEngaging (IntraOral)

ScanBody DirectEngaging

Ref. DDG-120341

Technical Specifications

• For scan Implant position. Titanium.• Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

29www.ddg-scanlab.com

Analog

Straight Zrabutment 1 mm

Titanium HealingCap

Engagingcastable abutment

Titanium engagingInterface

Non Engagingcastable abutment

Straight Zrabutment 2 mm

Straight Titaniumabutment

Screw

Titanium Non engaging Interface

Ref. DDG-120301

Ref. DDG-120325

Ref. DDG-120350

Ref. DDG-120311

Ref. DDG-120331

Ref. DDG-120310

Ref. DDG-120326

Ref. DDG-120321

Ref. DDG-120320

Ref. DDG-120330

Ref. DDG-120340

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

• Implant Replica.• Exact.• For duplicate the shape and position of the implant platform.• Made in Stainless steel.

• For cemented resto-rations. Engaging.• Zirconium High Aesthetics.• With Titanium Interface. • High Precision. • High Strength.• Made in CIP zirconia. • Made in Titanium 5 grade.• Interfaces Anodized.

•for allow gingival tisseus to heal prior to the placement abutment and maintain proper spacing in the oral cavity. • DDG-120350-2mm• DDG-120352-4mm• DDG-120354-6mm• DDG-120356-8mm• DDG-120356-8mm• Made in Titanium 5 grade.

• Cast component.• Engaging. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

•For screw-cement reteined restorations. • Engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

• Cast component.• Non engaging. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

• For cemented resto-rations. Engaging.• Zirconium High Aesthetics.• With Titanium Interface. • High Precision. • High Strength.• Made in CIP zirconia. • Made in Titanium 5 grade.• Interfaces Anodized.

• Used for bridge abut-ment and crown.• Engaging.• High Quality.• High Strength.• Made in titanium 5 grade.

• For fixation of the restoration.• Normal type.. • High Quality.• High Strength.• Made in titanium 5 grade.

•For screw-cement reteined restorations. • Non engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

• For scan Implant position. Titanium.• Non Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

ScanBody DirectNon Engaging

Page 30: Catalog DDG-Components 2013 (v 8 2013)

AstraTech® Osseospeed Tx® 4.5/5.0 (Ref.DDG-1203) Part 2

DDG-1200 System

Page 31: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t sD D G - C o m p o n e n t s

31www.ddg-scanlab.com

AnalogConic 20º

ScanBody DirectEngaging Conic 20º

Non engagingcastable abutment 20º

Scanbody Non engaging

Titaniumabutmant conic 20º

ScanBody DirectEngaging Conic 45º

Screwfor abutment 20º

ScanBody DirectEngaging

Ref. DDG-120202

Ref. DDG-120443

Ref. DDG-120311

Ref. DDG-120334

Ref. DDG-120306

Ref. DDG-120543

Ref. DDG-120321

Ref. DDG-120343

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

•For screw-cement reteined restorations. • Engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade..

• For scan Implant position. Titanium.• For Conic abutment 20º. • High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.

• Cast component.• Non engaging. • For create Bridge.• For Conic abutment 20º. • Cnc Machined.• Made in Delrin Plastic.

• For scan Implant position. Titanium.• Non Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

•For screw-reteined restorations. • Non engaging.• DDG-120306-0.5mm• DDG-120307-1mm• DDG-120308-2mm• DDG-120309-4mm• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

• For scan Implant position. Titanium.• For Conic abutment 45º. • High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.

• For fixation of the restoration.• For Conic abutment 20º. • High Quality.• High Strength.• Made in titanium 5 grade.

• For scan Implant position. Titanium.• High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

Page 32: Catalog DDG-Components 2013 (v 8 2013)

Klockner® Essential 4.5 (Ref.DDG-1301)

DDG-1300 System

Page 33: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t sD D G - C o m p o n e n t s

33www.ddg-scanlab.com

Screw

Titanium Non engaging Interface

Engagingcastable abutment

Scanbody InterfacesNon engaging

Non Engagingcastable abutment

Scanbody InterfacesEngaging (IntraOral)

Titanium Engaging Interface

ScanBody DirectEngaging

Ref. DDG-130180

Ref. DDG-130130

Ref. DDG-130111

Ref. DDG-130140

Ref. DDG-1130110

Ref. DDG-130141

Ref. DDG-130131

Ref. DDG-130143

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

• For fixation of the restoration.• Normal type.. • High Quality.• High Strength.• Made in titanium 5 grade.

•For screw-cement reteined restorations. • Non Engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.(90% of cases).

• Cast component.• Engaging. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

• For scan Implant position. Titanium.• Non engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

• Cast component.• Non engaging. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

• For scan Implant position. Titanium.• Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).(90% of cases).

•For screw-cement reteined restorations. • Engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

• For scan Implant position. Titanium.• High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

Analog

Ref. DDG-130101

Technical Specifications

•For screw-cement reteined restorations. • Engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade..

D D G - C o m p o n e n t s

Page 34: Catalog DDG-Components 2013 (v 8 2013)

Klockner® Essential 6.0 (Ref.DDG-1302)

DDG-1300 System

Page 35: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t sD D G - C o m p o n e n t s

35www.ddg-scanlab.com

Screw

Titanium Non engaging Interface

Engagingcastable abutment

Scanbody InterfacesNon engaging

Non Engagingcastable abutment

Scanbody InterfacesEngaging (IntraOral)

Titanium Engaging Interface

ScanBody DirectEngaging

Ref. DDG-130280

Ref. DDG-130230

Ref. DDG-130211

Ref. DDG-130240

Ref. DDG-130210

Ref. DDG-130241

Ref. DDG-130231

Ref. DDG-130243

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

• For fixation of the restoration.• Normal type.. • High Quality.• High Strength.• Made in titanium 5 grade.

•For screw-cement reteined restorations. • Non Engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.(90% of cases).

• Cast component.• Engaging. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

• For scan Implant position. Titanium.• Non engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

• Cast component.• Non engaging. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

• For scan Implant position. Titanium.• Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).(90% of cases).

•For screw-cement reteined restorations. • Engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

• For scan Implant position. Titanium.• High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

Analog

Ref. DDG-130201

Technical Specifications

•For screw-cement reteined restorations. • Engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade..

D D G - C o m p o n e n t s

Page 36: Catalog DDG-Components 2013 (v 8 2013)

Nobel Biocare® Bränemark® 3.3 (Ref.DDG-2101)

DDG-2100 System

Page 37: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

37www.ddg-scanlab.com

Straight Zrabutment 1 mm

Screw

Non Engagingcastable abutment

Titanium engagingInterface

ScanBody InterfacesNon engaging

Analog

Straight Zrabutment 2 mm

Scanbody InterfacesEngaging (IntraOral)

Engagingcastable abutment

Titanium Non engaging Interface

ScanBody DirectEngaging

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

• For cemented resto-rations. Engaging.• Zirconium High Aesthetics.• With Titanium Interface. • High Precision. • High Strength.• Made in CIP zirconia. • Made in Titanium 5 grade.

• Interfaces Anodized.

• For fixation of the restoration. • High Quality.• High Strength.• Made in titanium 5

grade.

• Cast component.• Non engaging. • For create a bridge.• Cnc Machined.

• Made in Delrin Plastic.

•For screw-cement reteined restorations. • Engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

• For scan Implant position. • Non engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

• Implant Replica.• Exact.• For duplicate the shape and position of the implant platform.

• Made in Stainless steel.

• For cemented resto-rations. Engaging.• Zirconium High Aesthetics.• With Titanium Interface. • High Precision. • High Strength.• Made in CIP zirconia. • Made in Titanium 5 grade.

• Interfaces Anodized.

• For scan Implant position. • Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

• Cast component.• Engaging. • For create a bridge.• Cnc Machined.• Made in Delrin Plastic.

•For screw-cement reteined restorations. • Non engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

• For scan Implant position. • High Accuracy• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.

(90% of cases).

D D G - C o m p o n e n t s

Ref. DDG-210120

Ref. DDG-210180

Ref. DDG-210110

Ref. DDG-210131

Ref. DDG-210140

Ref. DDG-210101

Ref. DDG-210121

Ref. DDG-210111

Ref. DDG-210130

Ref. DDG-210143Ref. DDG-210141

Page 38: Catalog DDG-Components 2013 (v 8 2013)

Nobel Biocare® Bränemark® 4.1 (Ref.DDG-2102) Part. 1

DDG-2100 System

Page 39: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

39www.ddg-scanlab.com

Analog

Straight Zrabutment 1 mm

Straight Titaniumabutment Engaging

Engagingcastable abutment

Titanium engagingInterface

Cr-Co Base EngagingCastable abutment

Non Engagingcastable abutment

Straight Zrabutment 2 mm

Straight Titaniumabutment Non Engaging

Locator abutment

Titanium Non engaging Interface

Cr-Co Base Non engagingCastable abutment

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

• Implant Replica.• Exact.• For duplicate the shape and position of the implant platform.

• Made in Stainless steel.

• For cemented resto-rations. Engaging.• Zirconium High Aesthetics.• With Titanium Interface. • High Precision. • High Strength.• Made in CIP zirconia. • Made in Titanium 5 grade.

• Interfaces Anodized.

• Used for bridge abut-ment and crown.• Engaging.• High Quality.• High Strength.• Made in titanium 5

grade.

• Cast component.• Engaging. • For create a bridge.• Cnc Machined.• Made in Delrin Plastic.

•For screw-cement reteined restorations. • Engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

• Cast-On component.• Engaging. • For create a Crown (Screw retened) and Bridge (cemented).• Base Cr-Co.• High Quality.• High Strength.• Cnc Machined.• Made in Delrin Plastic and Cr-Co.

• Cast component.• Non engaging. • For create a bridge.• Cnc Machined.

• Made in Delrin Plastic.

• For cemented resto-rations. Non engaging.• Zirconium High Aesthetics.• With Titanium Interface. • High Precision. • High Strength.• Made in CIP zirconia. • Made in Titanium 5 grade.

• Interfaces Anodized.

• Used for bridge abut-ment and crown.• Non engaging.• High Quality.• High Strength.• Made in titanium 5 grade.

• Abutment for Overdentadures. • High accuracy.• High Quality..• Made in Titanium 5 grade.

•For screw-cement reteined restorations. • Non engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

• Cast-On component.• Engaging. • For create a Crown (Screw retened) and Bridge (cemented).• Base Cr-Co.• High Quality.• High Strength.• Cnc Machined.• Made in Delrin Plastic

and Cr-Co.

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

Ref. DDG-210225

Ref. DDG-210221

Ref. DDG-210211

Ref. DDG-210231

Ref. DDG-210213

Ref. DDG-210210

Ref. DDG-210226

Ref. DDG-210260

Ref. DDG-210230

Ref. DDG-210212Ref. DDG-210220

Ref. DDG-210201

Page 40: Catalog DDG-Components 2013 (v 8 2013)

Nobel Biocare Bränemark® 4.1 (Ref.DDG-2102) Part. 2

DDG-2100 System

Page 41: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

41www.ddg-scanlab.com

Angled titaniumabutment 15º

Screw UnigripDrive Flat seat

Scanbody InterfacesEngaging (IntraOral)

Screw

Titanium Impressioncoping OpenTray

ScanBody DirectNon engaging

Angled titaniumabutment 25º

Titanium Healingabutment

Titanium Healingabutment

Screw

Titanium Impressioncoping ClosedTray

ScanBody DirectEngaging

Ref. DDG-210221

Ref. DDG-210282

Ref. DDG-210241

Ref. DDG-210280

Ref. DDG-210270

Ref. DDG-210242

Ref. DDG-210224

Ref. DDG-210250

Ref. DDG-210240

Ref. DDG-210281

Ref. DDG-210271

Ref. DDG-210243

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

• Used for bridge abut-ment and crown.• Angled 15º.• Engaging.• High Quality.• High Strength.• Made in titanium 5 grade.

• For fixation of the restoration.• Flat seat. • High Quality.• High Strength.• Made in titanium 5 grade.

• For scan Implant position. • Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

• For fixation of the restoration.• Unigrip screwdriver. • High Quality.• High Strength.• Made in titanium 5 grade.

• Used to mark the placement of a implant in an impression.• Open Tray.• Engaging.• High Quality.• Made in Titanium 5 grade.

• For scan Implant position. • High Accuracy• Non engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

• Used for bridge abut-ment and crown.• Angled 25º.• Engaging.• High Quality.• High Strength.• Made in titanium 5 grade.

•for allow gingival tisseus to heal prior to the placement abutment and maintain proper spacing in the oral cavity. • DDG-210250-2mm• DDG-210251-3mm• DDG-210252-4mm• DDG-210253-5mm• Made in Titanium 5 grade.

• For scan Implant position. • Non Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

• For fixation of the restoration. • Low profile.• 1.2 Hex.• High Quality.• High Strength.• Made in titanium 5 grade.

• Used to mark the placement of a implant in an impression.• Closed Tray.• Engaging.• High Quality.• Made in Titanium 5 grade.

• For scan Implant position. • High Accuracy• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

Page 42: Catalog DDG-Components 2013 (v 8 2013)

Nobel Biocare Bränemark® 5.1 (Ref.DDG-2103)

DDG-2100 System

Page 43: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

43www.ddg-scanlab.com

Screw Non engagingcastable abutment

Engagingcastable abutment

Titanium Non engaging Interface

ScanBody DirectEngaging

Ref. DDG-210380 Ref. DDG-210311Ref. DDG-210310

Ref. DDG-210301

Ref. DDG-210343

Technical Specifications Technical SpecificationsTechnical Specifications

Technical Specifications

Technical Specifications

• For fixation of the restoration. • High Quality.• High Strength.• Made in titanium 5 grade.

• Cast component.• Non engaging. • For create a bridge.• Cnc Machined.• Made in Delrin Plastic.

• Cast component.• Engaging. • For create a bridge.• Cnc Machined.• Made in Delrin Plastic.

• Implant Replica.• Exact.• For duplicate the shape and position of the implant platform.• Made in Stainless steel.

• For scan Implant position. • High Accuracy• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

D D G - C o m p o n e n t s

Page 44: Catalog DDG-Components 2013 (v 8 2013)

Dentsply Friadent® Xive® 3.4 (Ref.DDG-2201)

DDG-2200 System

Page 45: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

Scanbody InterfacesNon engaging

ScanBody DirectEngaging

Ref. DDG-220140

Technical Specifications

• For scan Implant position. Titanium.• Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

45www.ddg-scanlab.com

Screw

Engagongcastable abutment

Scanbody InterfacesEngaging (IntraOral)

Non engagongcastable abutment

Ref. DDG-220183

Ref. DDG-220111

Ref. DDG-220141

Ref. DDG-220110

Ref. DDG-220143

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

• For fixation of the restoration.• Normal type.. • High Quality.• High Strength.• Made in titanium 5 grade.

• Cast component.• Engaging. • For create a bridge.• Cnc Machined.• Made in Delrin Plastic.

• For scan Implant position. Titanium.• Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

• Cast component.• Non engaging. • For create a bridge.• Cnc Machined.• Made in Delrin Plastic.

• For scan Implant position. Titanium.• High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

D D G - C o m p o n e n t s

ScanBody Direct Engaging

Analog

Ref. DDG-2201101

Technical Specifications

• Implant Replica.• Exact.• For duplicate the shape and position of the implant platform.• Made in Stainless steel.

D D G - C o m p o n e n t s

Page 46: Catalog DDG-Components 2013 (v 8 2013)

Dentsply Friadent® Xive® 3.8 (Ref.DDG-2202)

DDG-2200 System

Page 47: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

Scanbody InterfacesNon engaging

ScanBody DirectEngaging

Ref. DDG-220240

Technical Specifications

• For scan Implant position. Titanium.• Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

47www.ddg-scanlab.com

Screw

Engagongcastable abutment

Scanbody InterfacesEngaging (IntraOral)

Non engagongcastable abutment

Ref. DDG-220283

Ref. DDG-220211

Ref. DDG-220241

Ref. DDG-220210

Ref. DDG-220243

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

• For fixation of the restoration.• Normal type.. • High Quality.• High Strength.• Made in titanium 5 grade.

• Cast component.• Engaging. • For create a bridge.• Cnc Machined.• Made in Delrin Plastic.

• For scan Implant position. Titanium.• Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

• Cast component.• Non engaging. • For create a bridge.• Cnc Machined.• Made in Delrin Plastic.

• For scan Implant position. Titanium.• High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

D D G - C o m p o n e n t s

ScanBody Direct Engaging

Analog

Ref. DDG-2202101

Technical Specifications

• Implant Replica.• Exact.• For duplicate the shape and position of the implant platform.• Made in Stainless steel.

D D G - C o m p o n e n t s

Page 48: Catalog DDG-Components 2013 (v 8 2013)

Dentsply Friadent® Xive® 4.5 (Ref.DDG-2203)

DDG-2200 System

Page 49: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

Scanbody InterfacesNon engaging

ScanBody DirectEngaging

Ref. DDG-220340

Technical Specifications

• For scan Implant position. Titanium.• Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

49www.ddg-scanlab.com

Screw

Engagongcastable abutment

Scanbody InterfacesEngaging (IntraOral)

Non engagongcastable abutment

Ref. DDG-220383

Ref. DDG-220311

Ref. DDG-220341

Ref. DDG-220310

Ref. DDG-220343

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

• For fixation of the restoration.• Normal type.. • High Quality.• High Strength.• Made in titanium 5 grade.

• Cast component.• Engaging. • For create a bridge.• Cnc Machined.• Made in Delrin Plastic.

• For scan Implant position. Titanium.• Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

• Cast component.• Non engaging. • For create a bridge.• Cnc Machined.• Made in Delrin Plastic.

• For scan Implant position. Titanium.• High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

D D G - C o m p o n e n t s

ScanBody Direct Engaging

Analog

Ref. DDG-220301

Technical Specifications

• Implant Replica.• Exact.• For duplicate the shape and position of the implant platform.• Made in Stainless steel.

D D G - C o m p o n e n t s

Page 50: Catalog DDG-Components 2013 (v 8 2013)

Dentsply Friadent® Xive® 5.5 (Ref.DDG-2204)

DDG-2200 System

Page 51: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

Scanbody InterfacesNon engaging

ScanBody DirectEngaging

Ref. DDG-220340

Technical Specifications

• For scan Implant position. Titanium.• Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

51www.ddg-scanlab.com

Screw

Engagongcastable abutment

Scanbody InterfacesEngaging (IntraOral)

Non engagongcastable abutment

Ref. DDG-220383

Ref. DDG-220311

Ref. DDG-220341

Ref. DDG-220310

Ref. DDG-220443

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

• For fixation of the restoration.• Normal type.. • High Quality.• High Strength.• Made in titanium 5 grade.

• Cast component.• Engaging. • For create a bridge.• Cnc Machined.• Made in Delrin Plastic.

• For scan Implant position. Titanium.• Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

• Cast component.• Non engaging. • For create a bridge.• Cnc Machined.• Made in Delrin Plastic.

• For scan Implant position. Titanium.• High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

D D G - C o m p o n e n t s

ScanBody Direct Engaging

Analog

Ref. DDG-2203101

Technical Specifications

• Implant Replica.• Exact.• For duplicate the shape and position of the implant platform.• Made in Stainless steel.

D D G - C o m p o n e n t s

Page 52: Catalog DDG-Components 2013 (v 8 2013)

BTI® Internal® 4.1 (Ref.DDG-2301)

DDG-2300 System

Page 53: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

53www.ddg-scanlab.com

Analog

Straight Zrabutment 1 mm

Screw

Engagingcastable abutment

Titanium engagingInterface

Scanbody InterfacesNon engaging

Analog

Straight Zrabutment 2 mm

Scanbody InterfacesEngaging (IntraOral)

Non engaging castable abutment

Titanium Non engaging Interface

ScanBody DirectEngaging

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

• Implant Replica.• Exact.• For duplicate the shape and position of the implant platform.

• Made in Stainless steel.

• For cemented resto-rations. Engaging.• Zirconium High Aesthetics.• With Titanium Interface. • High Precision. • High Strength.• Made in CIP zirconia. • Made in Titanium 5 grade.

• Interfaces Anodized.

• For fixation of the restoration.• Normal type.. • High Quality.• High Strength.• Made in titanium 5

grade.

• Cast component.• Engaging. • For create a bridge.• Cnc Machined.• Made in Delrin Plastic.

•For screw-cement reteined restorations. • Engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

• For scan Implant position. • Non Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

• Implant Replica.• Exact.• For duplicate the shape and position of the implant platform.

• Made in Stainless steel.

• For cemented resto-rations. Non engaging.• Zirconium High Aesthetics.• With Titanium Interface. • High Precision. • High Strength.• Made in CIP zirconia. • Made in Titanium 5 grade.

• Interfaces Anodized.

• For scan Implant position. • Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

• Cast component.• Non engaging. • For create a bridge.• Cnc Machined.• Made in Delrin Plastic.

•For screw-cement reteined restorations. • Non engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

• For scan Implant position. Titanium.• High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.

(90% of cases).

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

Ref. DDG-230125

Ref. DDG-230183

Ref. DDG-230111

Ref. DDG-230131

Ref. DDG-230140

Ref. DDG-230101

Ref. DDG-230126

Ref. DDG-230110

Ref. DDG-230130

Ref. DDG-230143Ref. DDG-230141

Ref. DDG-420201

Page 54: Catalog DDG-Components 2013 (v 8 2013)

BTI® Internal® 5.5 (Ref.DDG-2302)

DDG-2300 System

Page 55: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

Scanbody InterfacesNon engaging

ScanBody DirectEngaging

Ref. DDG-230283

Technical Specifications

• For scan Implant position. • Non Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

55www.ddg-scanlab.com

Screw

Titanium engagingInterface

Scanbody InterfacesEngaging (IntraOral

Ref. DDG-230210

Ref. DDG-230201

Ref. DDG-230228

Ref. DDG-230211

Ref. DDG-230243

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

• For fixation of the restoration.• Normal type.. • High Quality.• High Strength.• Made in titanium 5 grade.

• Implant Replica.• Exact.• For duplicate the shape and position of the implant platform.• Made in Stainless steel.

• For scan Implant position. • Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

• Cast component.• Non engaging. • For create a bridge.• Cnc Machined.• Made in Delrin Plastic.

• For scan Implant position. Titanium.• High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

D D G - C o m p o n e n t s

ScanBody Direct Engaging

Non engagongcastable abutment

Page 56: Catalog DDG-Components 2013 (v 8 2013)

Nobel Biocare Nobel Active® 3.5 (Ref.DDG-3101)

DDG-3100 System

Page 57: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

57www.ddg-scanlab.com

Straight Zrabutment 1 mm

Scanbody InterfacesEngaging (IntraOral)

Engagingcastable abutment

Titanium engagingInterface

ScanBody DirectNon engaging

Non Engagingcastable abutment

Straight Zrabutment 2 mm

ScanBody InterfacesNon engaging

Screw

Titanium Non engaging Interface

ScanBody DirectEngaging

Ref. DDG-310125

Ref. DDG-310141

Ref. DDG-310111

Ref. DDG-310131

Ref. DDG-310142

Ref. DDG-310110

Ref. DDG-310126

Ref. DDG-310140

Ref. DDG-310183

Ref. DDG-310130

Ref. DDG-310143

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

• For cemented resto-rations. • Zirconium High Aesthetics.• With Titanium Interface. • High Precision. • High Strength.• Made in CIP zirconia. • Made in Titanium 5 grade.• Interfaces Anodized.

• For scan Implant position. • Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

• Cast component. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

•For screw-cement reteined restorations. • Engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

• For scan Implant position. • High Accuracy• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

• Cast component. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

• For cemented resto-rations. • Zirconium High Aesthetics.• With Titanium Interface. • High Precision. • High Strength.• Made in CIP zirconia. • Made in Titanium 5 grade.• Interfaces Anodized.

• For scan Implant position. • Non engaging.• For use in Laboratory and IntraOral.• On Titanium Inter-faces.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

• For fixation of the restoration. • High Quality.• High Strength.• Made in titanium 5 grade.

•For screw-cement reteined restorations. • Non engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

• For scan Implant position. • High Accuracy• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

Analog

Ref. DDG-310101

Technical Specifications

• Implant Replica.• Exact.• For duplicate the shape and position of the implant platform.• Made in Stainless steel.

Page 58: Catalog DDG-Components 2013 (v 8 2013)

Nobel Biocare Nobel Active® 4.3 (Ref.DDG-3102)

DDG-3100 System

Page 59: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

59www.ddg-scanlab.com

Straight Zrabutment 1 mm

Scanbody InterfacesEngaging (IntraOral)

Engagingcastable abutment

Titanium engagingInterface

ScanBody DirectNon engaging

Non Engagingcastable abutment

Straight Zrabutment 2 mm

ScanBody InterfacesNon engaging

Screw

Titanium Non engaging Interface

ScanBody DirectEngaging

Ref. DDG-310125

Ref. DDG-310241

Ref. DDG-310211

Ref. DDG-310231

Ref. DDG-310242

Ref. DDG-310210

Ref. DDG-310226

Ref. DDG-310240

Ref. DDG-310283

Ref. DDG-310230

Ref. DDG-310243

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

• For cemented resto-rations. • Zirconium High Aesthetics.• With Titanium Interface. • High Precision. • High Strength.• Made in CIP zirconia. • Made in Titanium 5 grade.• Interfaces Anodized.

• For scan Implant position. • Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

• Cast component. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

•For screw-cement reteined restorations. • Engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

• For scan Implant position. • High Accuracy• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

• Cast component. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

• For cemented resto-rations. • Zirconium High Aesthetics.• With Titanium Interface. • High Precision. • High Strength.• Made in CIP zirconia. • Made in Titanium 5 grade.• Interfaces Anodized.

• For scan Implant position. • Non engaging.• For use in Laboratory and IntraOral.• On Titanium Inter-faces.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

• For fixation of the restoration. • High Quality.• High Strength.• Made in titanium 5 grade.

•For screw-cement reteined restorations. • Non engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

• For scan Implant position. • High Accuracy• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

Analog

Ref. DDG-310201

Technical Specifications

• Implant Replica.• Exact.• For duplicate the shape and position of the implant platform.• Made in Stainless steel.

Page 60: Catalog DDG-Components 2013 (v 8 2013)

Zimmer® Internal Hex® 3.5 (Ref.DDG-3201) Part. 1

DDG-3200 System

Page 61: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

Angled titaniumabutment 15º

ScanBody DirectEngaging

Ref. DDG-320112

Technical Specifications

• Used for bridge abut-ment and crown.• Angled 15º.• Engaging.• DDG-32012-1mm • DDG-32013-2mm • High Quality.• High Strength.• Made in titanium 5 grade.

61www.ddg-scanlab.com

Analog

Straight Zrabutment 1 mm

Titanium HealingCap

Engagingcastable abutment

Titanium engagingInterface

Non Engagingcastable abutment

Straight Zrabutment 2 mm

Straight Titaniumabutment

Screw

Titanium Non engaging Interface

Ref. DDG-320101

Ref. DDG-320125

Ref. DDG-320146

Ref. DDG-320111

Ref. DDG-320131

Ref. DDG-320110

Ref. DDG-320126

Ref. DDG-320147

Ref. DDG-320183

Ref. DDG-320130

Ref. DDG-320114

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

• Implant Replica.• Exact.• For duplicate the shape and position of the implant platform.• Made in Stainless steel.

• For cemented resto-rations. Engaging.• Zirconium High Aesthetics.• With Titanium Interface. • High Precision. • High Strength.• Made in CIP zirconia. • Made in Titanium 5 grade.• Interfaces Anodized.

• Used for bridge abut-ment and crown.• Engaging.• 1 mm.• High Quality.• High Strength.• Made in titanium 5 grade.

• Cast component.• Engaging. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

•For screw-cement reteined restorations. • Engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

• Cast component.• Non engaging. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

• For cemented resto-rations. Engaging.• Zirconium High Aesthetics.• With Titanium Interface. • High Precision. • High Strength.• Made in CIP zirconia. • Made in Titanium 5 grade.• Interfaces Anodized.

• Used for bridge abut-ment and crown.• Engaging.• 2 mm.• High Quality.• High Strength.• Made in titanium 5 grade.

• For fixation of the restoration.• Normal type.. • High Quality.• High Strength.• Made in titanium 5 grade.

•For screw-cement reteined restorations. • Non engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

• Used for bridge abut-ment and crown.• Angled 25º.• Engaging.• DDG-32014-1mm • DDG-32015-2mm • High Quality.• High Strength.• Made in titanium 5 grade.

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

Angled titaniumabutment 25º

Page 62: Catalog DDG-Components 2013 (v 8 2013)

Zimmer® Internal Hex® 3.5 (Ref.DDG-3201) Part. 2

DDG-3200 System

Page 63: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

Scanbody InterfacesNon engaging

ScanBody DirectEngaging

Ref. DDG-320140

Technical Specifications

• For scan Implant position. Titanium.• Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

63www.ddg-scanlab.com

Impression copingOpen Tray

Titanium engagingInterface

Scanbody InterfacesEngaging (IntraOral)

Titanium Non engaging Interface

Ref. DDG-320170

Ref. DDG-320113

Ref. DDG-320141

Ref. DDG-320112

Ref. DDG-320143

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

• Used to mark the placement of a implant in an impression.• Open Tray.• Engaging.• High Quality.• Made in Titanium 5 grade.

• Cast-On component.• Engaging. • For create a Crown (Screw retened) and Bridge (cemented).• Base Cr-Co.• High Quality.• High Strength.• Cnc Machined.• Made in Delrin Plastic and Cr-Co.

• For scan Implant position. Titanium.• Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

• Cast-On component.• Non engaging. • For create a Bridge (cemented).• Base Cr-Co.• High Quality.• High Strength.• Cnc Machined.• Made in Delrin Plastic and Cr-Co.

• For scan Implant position. Titanium.• High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

D D G - C o m p o n e n t s

ScanBody Direct Engaging

Page 64: Catalog DDG-Components 2013 (v 8 2013)

Zimmer® Internal Hex.® 4.5 (Ref.DDG-3202)

DDG-3200 System

Page 65: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

Scanbody InterfacesNon engaging

ScanBody DirectEngaging

Ref. DDG-320240

Technical Specifications

• For scan Implant position. Titanium.• Non engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

65www.ddg-scanlab.com

Straight Zrabutment 1 mm

Screw

Engagingcastable abutment

Titanium engagingInterface

Analog

Straight Zrabutment 2 mm

Scanbody InterfacesEngaging (IntraOral)

Non engagingcastable abutment

Titanium Non engaging Interface

Ref. DDG-320225

Ref. DDG-320283

Ref. DDG-320211

Ref. DDG-320231

Ref. DDG-320201

Ref. DDG-320226

Ref. DDG-320241

Ref. DDG-320210

Ref. DDG-320230

Ref. DDG-320243

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

• For cemented resto-rations. Engaging.• Zirconium High Aesthetics.• With Titanium Interface. • High Precision. • High Strength.• Made in CIP zirconia. • Made in Titanium 5 grade.• Interfaces Anodized.

• For fixation of the restoration.• Normal type.. • High Quality.• High Strength.• Made in titanium 5 grade.

• Cast component.• Engaging. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

•For screw-cement reteined restorations. • Engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

• Implant Replica.• Exact.• For duplicate the shape and position of the implant platform.• Made in Stainless steel.

• For cemented resto-rations. Engaging.• Zirconium High Aesthetics.• With Titanium Interface. • High Precision. • High Strength.• Made in CIP zirconia. • Made in Titanium 5 grade.• Interfaces Anodized.

• For scan Implant position. Titanium.• Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

•For screw-cement reteined restorations. • Non engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

• For scan Implant position. Titanium.• Non Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

D D G - C o m p o n e n t s

ScanBody DirectNon Engaging

• Cast component.• Engaging. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

Analog Engagingcastable abutment

Non engagingcastable abutment

Straight Zrabutment 1 mm

Straight Zrabutment 2 mm

Titanium EngagingInterface

Titanium Non engagingInterface

Screw Scanbody InterfacesEngaging (IntraOral)

65www.ddg-scanlab.com

Page 66: Catalog DDG-Components 2013 (v 8 2013)

Zimmer® Internal Hex.® 5.7 (Ref.DDG-3203)

DDG-3200 System

Page 67: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

67www.ddg-scanlab.com

Screw Non engagingcastable abutment

Engagingcastable abutment

Analog

ScanBody DirectEngaging

Ref. DDG-320383 Ref. DDG-320310Ref. DDG-320311

Ref. DDG-320301

Ref. DDG-320343

Technical Specifications Technical SpecificationsTechnical Specifications

Technical Specifications

Technical Specifications

• For fixation of the restoration.• Normal type.. • High Quality.• High Strength.• Made in titanium 5 grade.

• Cast component.• Non engaging. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

• Cast component.• Engaging. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

• Implant Replica.• Exact.• For duplicate the shape and position of the implant platform.• Made in Stainless steel.

• For scan Implant position. Titanium.• High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

D D G - C o m p o n e n t s

Page 68: Catalog DDG-Components 2013 (v 8 2013)

Biocomp® (Ref.DDG-3301)

DDG-3300 System

Page 69: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s

69www.ddg-scanlab.com

ScanBody DirectNon Engaging

Ref. DDG-330143

Technical Specifications

• For scan Implant position. Titanium.• High Accuracy.• Non engaging.• Only for Bridge.• Not necessary screw.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

Page 70: Catalog DDG-Components 2013 (v 8 2013)

Biocomp® (Ref.DDG-3302)

DDG-3300 System

Page 71: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s

71www.ddg-scanlab.com

ScanBody DirectNon Engaging

Ref. DDG-330243

Technical Specifications

• For scan Implant position. Titanium.• High Accuracy.• Non engaging.• Only for Bridge.• Not necessary screw.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

Page 72: Catalog DDG-Components 2013 (v 8 2013)

Nobel Biocare MultiUnit® 4.8 (Ref.DDG-4101)

DDG-4100 System

Page 73: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

73www.ddg-scanlab.com

Screw

Impression copingClosed Tray

Non engagingcastable abutment

MultiUnit angled 17ºAbutment

Plastic Healing Cap

Analog

MultiUnitAbutment

Handling Tool

Temporary Abutment

MultiUnit angled 30ºAbutment

ScanBody DirectEngaging

Ref. DDG-410180

Ref. DDG-410171

Ref. DDG-410110

Ref. DDG-410195

Ref. DDG-410158

Ref. DDG-410101

Ref. DDG-410190

Ref. DDG-410127

Ref. DDG-410198

Ref. DDG-410142

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

• For fixation of the restoration. • High Quality.• High Strength.• Made in titanium 5 grade.

• Used to mark the placement of a implant in an impression.• Closed Tray.• Engaging.• High Quality.• Made in Titanium 5 grade.

• Cast component.• Non engaging. • For create a bridge.• Cnc Machined.• Made in Delrin Plastic.

•For screwreteined restorations. • Engaging• For Bränemark 4.1.• DDG-410195-3mm• DDG-410196-4mm• DDG-410197-5.5mm• with screw.• Made in Titanium 5 grade.

•for allow gingival tisseus to heal prior to the placement abutment and maintain proper spacing in the oral cavity. • Made in Delrin Plastic.

• Implant Replica.• Exact.• For duplicate the shape and position of the implant platform.• Made in Stainless steel.

•For screwreteined restorations. • Engaging• For Bränemark 4.1.• DDG-410190-2mm• DDG-410191-3mm• DDG-410192-4mm• DDG-410193-5mm• DDG-410194-7mm• with screw.• Made in Titanium 5 grade.

• Included with angled abutment Free.• Made in titanium 5 grade.

• Used for make Tem-porary.• Non Engaging.• High Quality.• High Strength.• Made in titanium 5 grade.

•For screwreteined restorations. • Engaging• For Bränemark 4.1.• DDG-410198-3mm• DDG-410199-4mm• DDG-410118-5.5mm• with screw.• Made in Titanium 5 grade.

• For scan Implant position. • High Accuracy• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

D D G - C o m p o n e n t s

Included with angled abutments

Page 74: Catalog DDG-Components 2013 (v 8 2013)

Nobel Biocare MultiUnit® 6.0 (Ref.DDG-4102)

DDG-4100 System

Page 75: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

75www.ddg-scanlab.com

Non engagingcastable abutment

Analog ScanBody DirectEngaging

Ref. DDG-410210 Ref. DDG-410242

Technical SpecificationsTechnical Specifications Technical Specifications

• Cast component.• Non engaging. • For create a bridge.• Cnc Machined.• Made in Delrin Plastic.

• Implant Replica.• Exact.• For duplicate the shape and position of the implant platform.• Made in Stainless steel.

• For scan Implant position. • High Accuracy• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

Ref. DDG-410201

Page 76: Catalog DDG-Components 2013 (v 8 2013)

BTI® External Hex® 3.5 (Ref.DDG-4201)

DDG-4200 System

Page 77: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

Scanbody InterfacesNon engaging

ScanBody DirectEngaging

Ref. DDG-420183

Technical Specifications

• For fixation of the restoration.• Normal type.. • High Quality.• High Strength.• Made in titanium 5 grade.

77www.ddg-scanlab.com

Impression copingOpen Tray

Titanium engagingInterface

Straight Titaniumabutment

Titanium Non engaging Interface

Ref. DDG-420110

Ref. DDG-420101

Ref. DDG-420128

Ref. DDG-420111

Ref. DDG-420143

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

• Cast component.• Non engaging. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

• Implant Replica.• Exact.• For duplicate the shape and position of the implant platform.• Made in Stainless steel.

• Used for bridge abut-ment and crown.• Engaging.• 2 mm.• High Quality.• High Strength.• Made in titanium 5 grade.

• Cast component.• Engaging. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

• For scan Implant position. Titanium.• High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

D D G - C o m p o n e n t s

ScanBody Direct Engaging

Page 78: Catalog DDG-Components 2013 (v 8 2013)

BTI® External Hex® 4.1 (Ref.DDG-4202) Part. 1

DDG-4200 System

Page 79: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

79www.ddg-scanlab.com

Analog

Straight Zrabutment 1 mm

Straight Titaniumabutment Engaging

Engagingcastable abutment

Titanium engagingInterface

Cr-Co Base EngagingCastable abutment

Non Engagingcastable abutment

Straight Zrabutment 2 mm

Straight Titaniumabutment Non Engaging

Locator abutment

Titanium Non engaging Interface

Cr-Co Base Non engagingCastable abutment

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

• Implant Replica.• Exact.• For duplicate the shape and position of the implant platform.

• Made in Stainless steel.

• For cemented resto-rations. Engaging.• Zirconium High Aesthetics.• With Titanium Interface. • High Precision. • High Strength.• Made in CIP zirconia. • Made in Titanium 5 grade.

• Interfaces Anodized.

• Used for bridge abut-ment and crown.• Engaging.• High Quality.• High Strength.• Made in titanium 5

grade.

• Cast component.• Engaging. • For create a bridge.• Cnc Machined.• Made in Delrin Plastic.

•For screw-cement reteined restorations. • Engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

• Cast-On component.• Engaging. • For create a Crown (Screw retened) and Bridge (cemented).• Base Cr-Co.• High Quality.• High Strength.• Cnc Machined.• Made in Delrin Plastic and Cr-Co.

• Cast component.• Non engaging. • For create a bridge.• Cnc Machined.

• Made in Delrin Plastic.

• For cemented resto-rations. Non engaging.• Zirconium High Aesthetics.• With Titanium Interface. • High Precision. • High Strength.• Made in CIP zirconia. • Made in Titanium 5 grade.

• Interfaces Anodized.

• Used for bridge abut-ment and crown.• Non engaging.• High Quality.• High Strength.• Made in titanium 5 grade.

• Abutment for Overdentadures. • High accuracy.• High Quality..• Made in Titanium 5 grade.

•For screw-cement reteined restorations. • Non engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

• Cast-On component.• Engaging. • For create a Crown (Screw retened) and Bridge (cemented).• Base Cr-Co.• High Quality.• High Strength.• Cnc Machined.• Made in Delrin Plastic

and Cr-Co.

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

Ref. DDG-420225

Ref. DDG-420221

Ref. DDG-420211

Ref. DDG-420231

Ref. DDG-420213

Ref. DDG-420210

Ref. DDG-420226

Ref. DDG-420260

Ref. DDG-420230

Ref. DDG-420218Ref. DDG-420220

Ref. DDG-420201

Page 80: Catalog DDG-Components 2013 (v 8 2013)

BTI® External Hex® 4.1 (Ref.DDG-4202) Part. 2

DDG-4200 System

Page 81: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

81www.ddg-scanlab.com

Angled titaniumabutment 15º

Screw UnigripDrive Flat seat

Scanbody InterfacesEngaging (IntraOral)

Screw

Titanium Impressioncoping OpenTray

ScanBody DirectNon engaging

Angled titaniumabutment 25º

Titanium Healingabutment

Scanbody InterfacesNon engaging

Screw

Titanium Impressioncoping ClosedTray

ScanBody DirectEngaging

Ref. DDG-420222

Ref. DDG-420282

Ref. DDG-420241

Ref. DDG-420280

Ref. DDG-420270

Ref. DDG-420242

Ref. DDG-420224

Ref. DDG-420250

Ref. DDG-420240

Ref. DDG-420281

Ref. DDG-420271

Ref. DDG-420243

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

• Used for bridge abut-ment and crown.• Angled 15º.• Engaging.• High Quality.• High Strength.• Made in titanium 5 grade.

• For fixation of the restoration.• Flat seat. • High Quality.• High Strength.• Made in titanium 5 grade.

• For scan Implant position. • Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

• For fixation of the restoration.• Unigrip screwdriver. • High Quality.• High Strength.• Made in titanium 5 grade.

• Used to mark the placement of a implant in an impression.• Open Tray.• Engaging.• High Quality.• Made in Titanium 5 grade.

• For scan Implant position. • High Accuracy• Non engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

• Used for bridge abut-ment and crown.• Angled 25º.• Engaging.• High Quality.• High Strength.• Made in titanium 5 grade.

•for allow gingival tisseus to heal prior to the placement abutment and maintain proper spacing in the oral cavity. • DDG-420250-2mm• DDG-420251-3mm• DDG-420252-4mm• DDG-420253-5mm• Made in Titanium 5 grade.

• For scan Implant position. • Non Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

• For fixation of the restoration. • Low profile.• 1.2 Hex.• High Quality.• High Strength.• Made in titanium 5 grade.

• Used to mark the placement of a implant in an impression.• Closed Tray.• Engaging.• High Quality.• Made in Titanium 5 grade.

• For scan Implant position. • High Accuracy• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

Page 82: Catalog DDG-Components 2013 (v 8 2013)

BTI® External Hex.® 5.7 (Ref.DDG-4203)

DDG-4200 System

Page 83: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

83www.ddg-scanlab.com

Screw Non engagingcastable abutment

Engagingcastable abutment

Straight titaniumabutment 2mm

ScanBody DirectEngaging

Ref. DDG-420383 Ref. DDG-420310Ref. DDG-420311

Ref. DDG-420317

Ref. DDG-420343

Technical Specifications Technical SpecificationsTechnical Specifications

Technical Specifications

Technical Specifications

• For fixation of the restoration.• Normal type.. • High Quality.• High Strength.• Made in titanium 5 grade.

• Cast component.• Non engaging. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

• Cast component.• Engaging. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

• Used for bridge abut-ment and crown.• 2 mmm.• Wide Shoulder.• Engaging.• High Quality.• High Strength.• Made in titanium 5 grade.

• For scan Implant position. Titanium.• High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

D D G - C o m p o n e n t sD D G - C o m p o n e n t s

Straight titaniumabutment 2mm

Ref. DDG-420316

Technical Specifications

• Used for bridge abut-ment and crown.• 2 mmm.• Engaging.• High Quality.• High Strength.• Made in titanium 5 grade.

Analog

Ref. DDG-420301

Technical Specifications

• Implant Replica.• Exact.• For duplicate the shape and position of the implant platform.• Made in Stainless steel.

D D G - C o m p o n e n t s

Page 84: Catalog DDG-Components 2013 (v 8 2013)

Microdent® Microdent System® 3.5 (Ref.DDG-4301)

DDG-4300 System

Page 85: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

Scanbody InterfacesNon engaging

ScanBody DirectEngaging

Ref. DDG-430140

Technical Specifications

• For scan Implant position. Titanium.• Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

85www.ddg-scanlab.com

Screw

Engagongcastable abutment

Scanbody InterfacesEngaging (IntraOral)

Non engagongcastable abutment

Ref. DDG-430183

Ref. DDG-430111

Ref. DDG-430141

Ref. DDG-430110

Ref. DDG-430143

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

• For fixation of the restoration.• Normal type.. • High Quality.• High Strength.• Made in titanium 5 grade.

• Cast component.• Engaging. • For create a bridge.• Cnc Machined.• Made in Delrin Plastic.

• For scan Implant position. Titanium.• Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

• Cast component.• Non engaging. • For create a bridge.• Cnc Machined.• Made in Delrin Plastic.

• For scan Implant position. Titanium.• High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

D D G - C o m p o n e n t s

ScanBody Direct Engaging

Analog

Ref. DDG-430101

Technical Specifications

• Implant Replica.• Exact.• For duplicate the shape and position of the implant platform.• Made in Stainless steel.

D D G - C o m p o n e n t s

Page 86: Catalog DDG-Components 2013 (v 8 2013)

Microdent® Microdent System® 4.2 (Ref.DDG-4302)

DDG-4300 System

Page 87: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

Scanbody InterfacesNon engaging

ScanBody DirectEngaging

Ref. DDG-430240

Technical Specifications

• For scan Implant position. Titanium.• Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

87www.ddg-scanlab.com

Screw

Engagongcastable abutment

Scanbody InterfacesEngaging (IntraOral)

Non engagongcastable abutment

Ref. DDG-430283

Ref. DDG-430211

Ref. DDG-430241

Ref. DDG-430210

Ref. DDG-430243

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

• For fixation of the restoration.• Normal type.. • High Quality.• High Strength.• Made in titanium 5 grade.

• Cast component.• Engaging. • For create a bridge.• Cnc Machined.• Made in Delrin Plastic.

• For scan Implant position. Titanium.• Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

• Cast component.• Non engaging. • For create a bridge.• Cnc Machined.• Made in Delrin Plastic.

• For scan Implant position. Titanium.• High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

D D G - C o m p o n e n t s

ScanBody Direct Engaging

Analog

Ref. DDG-430201

Technical Specifications

• Implant Replica.• Exact.• For duplicate the shape and position of the implant platform.• Made in Stainless steel.

D D G - C o m p o n e n t s

Page 88: Catalog DDG-Components 2013 (v 8 2013)

Microdent® Microdent System® 5.1 (Ref.DDG-4303)

DDG-4300 System

Page 89: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

Scanbody InterfacesNon engaging

ScanBody DirectEngaging

Ref. DDG-430340

Technical Specifications

• For scan Implant position. Titanium.• Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

89www.ddg-scanlab.com

Screw

Engagongcastable abutment

Scanbody InterfacesEngaging (IntraOral)

Non engagongcastable abutment

Ref. DDG-430383

Ref. DDG-430311

Ref. DDG-430341

Ref. DDG-430310

Ref. DDG-430343

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

• For fixation of the restoration.• Normal type.. • High Quality.• High Strength.• Made in titanium 5 grade.

• Cast component.• Engaging. • For create a bridge.• Cnc Machined.• Made in Delrin Plastic.

• For scan Implant position. Titanium.• Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

• Cast component.• Non engaging. • For create a bridge.• Cnc Machined.• Made in Delrin Plastic.

• For scan Implant position. Titanium.• High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

D D G - C o m p o n e n t s

ScanBody Direct Engaging

Analog

Ref. DDG-430301

Technical Specifications

• Implant Replica.• Exact.• For duplicate the shape and position of the implant platform.• Made in Stainless steel.

D D G - C o m p o n e n t s

Page 90: Catalog DDG-Components 2013 (v 8 2013)

Biomet 3i® Certain® 3.4 (Ref.DDG-5101) Part.1

DDG-5100 System

Page 91: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

91www.ddg-scanlab.com

Straight Zrabutment 1 mm

Non Engagingcastable abutment

Titanium engagingInterface

Analog

Straight Zrabutment 2 mm

Engagingcastable abutment

Titanium Non engagingInterface

Ref. DDG-510125

Ref. DDG-510110

Ref. DDG-510131

Ref. DDG-510101

Ref. DDG-510126

Ref. DDG-510111

Ref. DDG-510130

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

• For cemented resto-rations. Engaging.• Zirconium High Aesthetics.• With Titanium Interface. • High Precision. • High Strength.• Made in CIP zirconia. • Made in Titanium 5 grade.• Interfaces Anodized.

• Cast component.• Non engaging. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

•For screw-cement reteined restorations. • Engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

• Implant Replica.• Exact.• For duplicate the shape and position of the implant platform.• Made in Stainless steel.

• For cemented resto-rations. Engaging.• Zirconium High Aesthetics.• With Titanium Interface. • High Precision. • High Strength.• Made in CIP zirconia. • Made in Titanium 5 grade.• Interfaces Anodized.

• Cast component.• Engaging. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

•For screw-cement reteined restorations. • Non engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

D D G - C o m p o n e n t s

Page 92: Catalog DDG-Components 2013 (v 8 2013)

Biomet 3i® Certain® 3.4 (Ref.DDG-5101) Part.2

DDG-5100 System

Page 93: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

93www.ddg-scanlab.com

Titanium Impressioncoping Open Tray

Screw

Scanbody InterfacesNon engaging

Straight titanium abutment

Scanbody InterfacesEngaging (IntraOral)

Titanium Healingabutment

ScanBody DirectEngaging

Ref. DDG-510170

Ref. DDG-510183

Ref. DDG-510140

Ref. DDG-510121

Ref. DDG-510141

Ref. DDG-510150

Ref. DDG-510143

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

• Used to mark the placement of a implant in an impression.• Open Tray.• Engaging.• High Quality.• Made in Titanium 5 grade.

• For fixation of the restoration.• High Quality.• High Strength.• Made in titanium 5 grade.

• For scan Implant position.Titanium.• Non Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

• Used for bridge abut-ment and crown.• Engaging.• High Quality.• High Strength.• Made in titanium 5 grade.

• For scan Implant position. • Engaging.Titanium.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

•for allow gingival tisseus to heal prior to the placement abutment and maintain proper spacing in the oral cavity. • DDG-510150-2mm• DDG-510151-3mm• DDG-510152-4mm• Made in Titanium 5 grade.

• For scan Implant position. • High Accuracy.• Engaging.Titanium.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

D D G - C o m p o n e n t s

Page 94: Catalog DDG-Components 2013 (v 8 2013)

Biomet 3i® Certain® 4.1 (Ref.DDG-5102) Part. 1

DDG-5100 System

Page 95: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

95www.ddg-scanlab.com

Straight Zrabutment 1 mm

Non Engagingcastable abutment

Titanium engagingInterface

Analog

Straight Zrabutment 2 mm

Engagingcastable abutment

Titanium Non engagingInterface

Ref. DDG-510225

Ref. DDG-510210

Ref. DDG-510231

Ref. DDG-510201

Ref. DDG-510226

Ref. DDG-510211

Ref. DDG-510230

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

• For cemented resto-rations. Engaging.• Zirconium High Aesthetics.• With Titanium Interface. • High Precision. • High Strength.• Made in CIP zirconia. • Made in Titanium 5 grade.• Interfaces Anodized.

• Cast component.• Non engaging. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

•For screw-cement reteined restorations. • Engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

• Implant Replica.• Exact.• For duplicate the shape and position of the implant platform.• Made in Stainless steel.

• For cemented resto-rations. Engaging.• Zirconium High Aesthetics.• With Titanium Interface. • High Precision. • High Strength.• Made in CIP zirconia. • Made in Titanium 5 grade.• Interfaces Anodized.

• Cast component.• Engaging. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

•For screw-cement reteined restorations. • Non engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

Page 96: Catalog DDG-Components 2013 (v 8 2013)

Biomet 3i® Certain® 4.1 (Ref.DDG-5102) Part. 2

DDG-5100 System

Page 97: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

97www.ddg-scanlab.com

Screw

Titanium Healingabutment

Titanium Impressioncoping Open Tray

Scanbody InterfacesNon engaging

Screw

Scanbody InterfacesEngaging (IntraOral)

Straight titanium abutment

Titanium Impressioncoping Closed Tray

ScanBody DirectEngaging

Ref. DDG-510206

Ref. DDG-510250

Ref. DDG-510270

Ref. DDG-510240

Ref. DDG-510283

Ref. DDG-510241

Ref. DDG-510221

Ref. DDG-510271

Ref. DDG-510243

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

• For fixation of the restoration.• Wide size. • High Quality.• High Strength.• Made in titanium 5 grade.

•for allow gingival tisseus to heal prior to the placement abutment and maintain proper spacing in the oral cavity. • DDG-510250-2mm• DDG-510251-3mm• DDG-510252-4mm• Made in Titanium 5 grade.

• Used to mark the placement of a implant in an impression.• Open Tray.• Engaging.• High Quality.• Made in Titanium 5 grade.

• For scan Implant position. Titanium.• Non Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

• For fixation of the restoration.• Normal size• High Quality.• High Strength.• Made in titanium 5 grade.

• For scan Implant position. • Engaging.Titanium.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

• Used for bridge abut-ment and crown.• Engaging.• High Quality.• High Strength.• Made in titanium 5 grade.

• Used to mark the placement of a implant in an impression.• Closed Tray.• Engaging.• High Quality.• Made in Titanium 5 grade.

• For scan Implant position. Titanium.• High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

D D G - C o m p o n e n t s

Page 98: Catalog DDG-Components 2013 (v 8 2013)

Biomet 3i® Certain® 5.0 (Ref.DDG-5103) Part. 1

DDG-5100 System

Page 99: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

99www.ddg-scanlab.com

Straight Zrabutment 1 mm

Non Engagingcastable abutment

Titanium engagingInterface

Analog

Straight Zrabutment 2 mm

Engagingcastable abutment

Titanium Non engagingInterface

Ref. DDG-510325

Ref. DDG-510310

Ref. DDG-510331

Ref. DDG-510301

Ref. DDG-510326

Ref. DDG-510311

Ref. DDG-510330

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

• For cemented resto-rations. Engaging.• Zirconium High Aesthetics.• With Titanium Interface. • High Precision. • High Strength.• Made in CIP zirconia. • Made in Titanium 5 grade.• Interfaces Anodized.

• Cast component.• Non engaging. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

•For screw-cement reteined restorations. • Engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

• Implant Replica.• Exact.• For duplicate the shape and position of the implant platform.• Made in Stainless steel.

• For cemented resto-rations. Engaging.• Zirconium High Aesthetics.• With Titanium Interface. • High Precision. • High Strength.• Made in CIP zirconia. • Made in Titanium 5 grade.• Interfaces Anodized.

• Cast component.• Engaging. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

•For screw-cement reteined restorations. • Non engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

D D G - C o m p o n e n t s

Page 100: Catalog DDG-Components 2013 (v 8 2013)

Biomet 3i® Certain® 5.0 (Ref.DDG-5103) Part. 2

DDG-5100 System

Page 101: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

101www.ddg-scanlab.com

Screw

Titanium Healingabutment

Titanium Impressioncoping Open Tray

Scanbody InterfacesNon engaging

Screw

Scanbody InterfacesEngaging (IntraOral)

Straight titanium abutment

Titanium Impressioncoping Closed Tray

ScanBody DirectEngaging

Ref. DDG-510306

Ref. DDG-510350

Ref. DDG-510370

Ref. DDG-510340

Ref. DDG-510383

Ref. DDG-510341

Ref. DDG-510321

Ref. DDG-510371

Ref. DDG-510343

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

• For fixation of the restoration.• Wide size. • High Quality.• High Strength.• Made in titanium 5 grade.

•for allow gingival tisseus to heal prior to the placement abutment and maintain proper spacing in the oral cavity. • DDG-510350-2mm• DDG-510351-3mm• DDG-510352-4mm• Made in Titanium 5 grade.

• Used to mark the placement of a implant in an impression.• Open Tray.• Engaging.• High Quality.• Made in Titanium 5 grade.

• For scan Implant position. Titanium.• Non Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

• For fixation of the restoration.• Normal size• High Quality.• High Strength.• Made in titanium 5 grade.

• For scan Implant position. Titanium.• Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

• Used for bridge abut-ment and crown.• Engaging.• High Quality.• High Strength.• Made in titanium 5 grade.

• Used to mark the placement of a implant in an impression.• Closed Tray.• Engaging.• High Quality.• Made in Titanium 5 grade.

• For scan Implant position. Titanium.• High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

D D G - C o m p o n e n t s

Page 102: Catalog DDG-Components 2013 (v 8 2013)

Klockner® SK2® 4.3 (Ref.DDG-5201)

DDG-5200 System

Page 103: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

103www.ddg-scanlab.com

Straight titanium abutment

Titanium Impressioncoping Closed Tray

Non Engagingcastable abutment

Screw

Titanium Healingabutment

Analog

Screw

Titanium Healingabutment

Engagingcastable abutment

Titanium Impressioncoping Open Tray

ScanBody DirectEngaging

Ref. DDG-520128

Ref. DDG-520171

Ref. DDG-520110

Ref. DDG-520188

Ref. DDG-520153

Ref. DDG-520101

Ref. DDG-520187

Ref. DDG-520154

Ref. DDG-520111

Ref. DDG-520170

Ref. DDG-520143

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

• Used for bridge abut-ment and crown.• Engaging.• High Quality.• High Strength.• Made in titanium 5 grade.

• Used to mark the placement of a implant in an impression.• Closed Tray.• Engaging.• High Quality.• Made in Titanium 5 grade.

• Cast component.• Non engaging. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

• For fixation of the restoration.• For cross Screwdriver. • High Quality.• High Strength.• Made in titanium 5 grade.

•for allow gingival tisseus to heal prior to the placement abutment and maintain proper spacing in the oral cavity. • Height 5mm• Made in Titanium 5 grade.

• Implant Replica.• Exact.• For duplicate the shape and position of the implant platform.• Made in Stainless steel

• For fixation of the restoration.• Normal type.. • High Quality.• High Strength.• Made in titanium 5 grade.

•for allow gingival tisseus to heal prior to the placement abutment and maintain proper spacing in the oral cavity. • Height 5mm• Made in Titanium 5 grade.

• Cast component.• Engaging. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

• Used to mark the placement of a implant in an impression.• Open Tray.• Engaging.• High Quality.• Made in Titanium 5 grade.

• For scan Implant position. Titanium.• High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

D D G - C o m p o n e n t s

Page 104: Catalog DDG-Components 2013 (v 8 2013)

Osstem® GS System® Mini (Ref.DDG-5301)

DDG-5300 System

Page 105: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s

105www.ddg-scanlab.com

ScanBody DirectEngaging

Ref. DDG-530143

Technical Specifications

• For scan Implant position. Titanium.• High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Abutment Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

Page 106: Catalog DDG-Components 2013 (v 8 2013)

Osstem® GS System® Regular (Ref.DDG-5302)

DDG-5300 System

Page 107: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s

107www.ddg-scanlab.com

ScanBody DirectEngaging

Ref. DDG-530243

Technical Specifications

• For scan Implant position. Titanium.• High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Abutment Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

Page 108: Catalog DDG-Components 2013 (v 8 2013)

Biomet 3i® External Hex 3.25 (Ref.DDG-6101)

DDG-6100 System

Page 109: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

109www.ddg-scanlab.com

Straight Zrabutment 1 mm

Screw

Engagingcastable abutment

Titanium engagingInterface

ScanBody InterfacesNon engaging

Non Engagingcastable abutment

Straight Zrabutment 2 mm

Scanbody InterfacesEngaging (IntraOral)

Screw

Titanium Non engaging Interface

ScanBody DirectEngaging

Ref. DDG-610125

Ref. DDG-610186

Ref. DDG-610111

Ref. DDG-610131

Ref. DDG-610140

Ref. DDG-610110

Ref. DDG-610226

Ref. DDG-610141

Ref. DDG-610184

Ref. DDG-610130

Ref. DDG-610243

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

• For cemented resto-rations. • Zirconium High Aesthetics.• With Titanium Interface. • High Precision. • High Strength.• Made in CIP zirconia. • Made in Titanium 5 grade.• Interfaces Anodized.

• For fixation of the restoration. • Square drive.• High Quality.• High Strength.• Made in titanium 5 grade.

• Cast component. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

•For screw-cement reteined restorations. • Engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

• For scan Implant position. • Non engaging.• For use in Laboratory and IntraOral.• On Titanium Inter-faces.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

• Cast component. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

• For cemented resto-rations. • Zirconium High Aesthetics.• With Titanium Interface. • High Precision. • High Strength.• Made in CIP zirconia. • Made in Titanium 5 grade.• Interfaces Anodized.

• For scan Implant position. • Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

• For fixation of the restoration. • High Quality.• High Strength.• DDG-610184 1,2hex• DDG-610185 1,25hex• Made in titanium 5 grade.

•For screw-cement reteined restorations. • Non engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

• For scan Implant position. • High Accuracy• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

Analog

Ref. DDG-610101

Technical Specifications

• Implant Replica.• Exact.• For duplicate the shape and position of the implant platform.• Made in Stainless steel.

Page 110: Catalog DDG-Components 2013 (v 8 2013)

Biomet 3i® External Hex 4.1 (Ref.DDG-6102) Part. 1

DDG-6100 System

Page 111: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

111www.ddg-scanlab.com

Analog

Straight Zrabutment 1 mm

Straight Titaniumabutment Engaging

Engagingcastable abutment

Titanium engagingInterface

Cr-Co Base EngagingCastable abutment

Non Engagingcastable abutment

Straight Zrabutment 2 mm

Straight Titaniumabutment Non Engaging

Locator abutment

Titanium Non engaging Interface

Cr-Co Base Non engaging

Castable abutment

Ref. DDG-610201

Ref. DDG-610225

Ref. DDG-610221

Ref. DDG-610211

Ref. DDG-610231

Ref. DDG-610213

Ref. DDG-610210

Ref. DDG-610226

Ref. DDG-610220

Ref. DDG-610260

Ref. DDG-610230

Ref. DDG-610212

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

• Implant Replica.• Exact.• For duplicate the shape and position of the implant platform.• Made in Stainless steel.

• For cemented resto-rations. Engaging.• Zirconium High Aesthetics.• With Titanium Interface. • High Precision. • High Strength.• Made in CIP zirconia. • Made in Titanium 5 grade.• Interfaces Anodized.

• Used for bridge abut-ment and crown.• Engaging.• High Quality.• High Strength.• Made in titanium 5 grade.

• Cast component.• Engaging. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

•For screw-cement reteined restorations. • Engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

• Cast-On component.• Engaging. • For create a crown and a custom abutment for bridge.• For create a custom abutment for bridge.• Cnc Machined.• Made in Delrin Plastic and Cr-Co HQ.• Built-in library Cad.

• Cast component.• Non engaging. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

• For cemented resto-rations. Engaging.• Zirconium High Aesthetics.• With Titanium Interface. • High Precision. • High Strength.• Made in CIP zirconia. • Made in Titanium 5 grade.• Interfaces Anodized.

• Used for bridge abutment.• Non Engaging.• High Quality.• High Strength.• Made in titanium 5 grade.

• Abutment for Overdentadures. • High accuracy.• Screw reteined.• Made in Titanium 5 grade.

•For screw-cement reteined restorations. • Non engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

• Cast-On component.• Non Engaging. • For create a custom abutment for bridge.• Cnc Machined.• Made in Delrin Plastic and Cr-Co HQ.• Built-in library Cad.

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

Page 112: Catalog DDG-Components 2013 (v 8 2013)

Biomet 3i® External Hex 4.1 (Ref.DDG-6102) Part. 2

DDG-6100 System

Page 113: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

113www.ddg-scanlab.com

Angled Titaniumabutment 15º

Screw UnigripDrive Flat seat

Scanbody InterfacesEngaging (IntraOral)

Screw UnigripDrive Tapered seat

Titanium Impressioncoping Open Tray

ScanBody DirectNon engaging

Angled Titaniumabutment 25º

Titanium Impressioncoping Closed Tray

Scanbody InterfacesNon engaging

Screw 1.2low profile

Titanium Healingabutment

ScanBody DirectEngaging

Ref. DDG-610222

Ref. DDG-610282

Ref. DDG-610241

Ref. DDG-610280

Ref. DDG-610271

Ref. DDG-610242

Ref. DDG-610224

Ref. DDG-610270

Ref. DDG-610240

Ref. DDG-610281

Ref. DDG-610250

Ref. DDG-610243

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

• Used for bridge abut-ment and crown.• Angled 15º.• Engaging.• High Quality.• High Strength.• Made in titanium 5 grade.

• For fixation of the restoration.• Flat seat. • High Quality.• High Strength.• Made in titanium 5 grade.

• For scan Implant position. • Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

• For fixation of the restoration.• Unigrip screwdriver. • High Quality.• High Strength.• Made in titanium 5 grade.

• Used to mark the placement of a implant in an impression.• Open Tray.• Engaging.• High Quality.• Made in Titanium 5 grade.

• For scan Implant position. • High Accuracy.• Special Edition.• Non Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

• Used for bridge abut-ment and crown.• Angled 25º.• Engaging.• High Quality.• High Strength.• Made in titanium 5 grade.

• Used to mark the placement of a implant in an impression.• Closed Tray.• Engaging.• High Quality.• Made in Titanium 5 grade.

• For scan Implant position. • Non Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

• For fixation of the restoration. • Low profile.• 1.2 Hex.• High Quality.• High Strength.• Made in titanium 5 grade.

•for allow gingival tisseus to heal prior to the placement abutment and maintain proper spacing in the oral cavity. • DDG-210250-2mm• DDG-210251-3mm• DDG-210252-4mm• DDG-210253-5mm• Made in Titanium 5 grade.

• For scan Implant position. • High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

Page 114: Catalog DDG-Components 2013 (v 8 2013)

Biomet 3i® External Hex 5.0 (Ref.DDG-6103)

DDG-6100 System

Page 115: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

115www.ddg-scanlab.com

Screw

Non Engagingcastable abutment

Screw

Analog

Screw

Engagingcastable abutment

ScanBody DirectEngaging

Ref. DDG-610384

Ref. DDG-610310

Ref. DDG-610386

Ref. DDG-610301

Ref. DDG-610385

Ref. DDG-610311

Ref. DDG-610343

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

• For fixation of the restoration.• Unigrip screwdriver. • High Quality.• High Strength.• Made in titanium 5 grade.

• Cast component.• Non engaging. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

• For fixation of the restoration.• Unigrip screwdriver. • High Quality.• High Strength.• Made in titanium 5 grade.

• Implant Replica.• Exact.• For duplicate the shape and position of the implant platform.• Made in Stainless steel.

• For fixation of the restoration.• Unigrip screwdriver. • High Quality.• High Strength.• Made in titanium 5 grade.

• Cast component.• Engaging. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

• For scan Implant position. • High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

D D G - C o m p o n e n t s

Page 116: Catalog DDG-Components 2013 (v 8 2013)

Implant Direct® Bar abutment® (Ref.DDG-6201)

DDG-6200 System

Page 117: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s

117www.ddg-scanlab.com

ScanBody DirectNon Engaging

Ref. DDG-620143

Technical Specifications

• For scan Implant position. Titanium.• High Accuracy.• Non engaging.• Only for Bridge.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

Page 118: Catalog DDG-Components 2013 (v 8 2013)

Straumann® Tissue Level® 3.5 (Ref.DDG-7101)

DDG-7100 System

Page 119: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s

119www.ddg-scanlab.com

ScanBody DirectEngaging

Ref. DDG-710143

Technical Specifications

• For scan Implant position. Titanium.• High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Abutment Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

Page 120: Catalog DDG-Components 2013 (v 8 2013)

Straumann® Tissue Level® 4.8 (Ref.DDG-7102) Part. 1

DDG-7100 System

Page 121: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

121www.ddg-scanlab.com

Analog

Straight Zrabutment 1 mm

Angled Titaniumabutment Engaging

Engagingcastable abutment

Titanium engagingInterface

Titanium Healingabutment

Non Engagingcastable abutment

Straight Zrabutment 2 mm

Angled Titaniumabutment Engaging

Straight Titaniumabutment Engaging

Titanium Non engaging Interface

SynOcta octagonal

nut abutment

Ref. DDG-710201

Ref. DDG-710225

Ref. DDG-710270

Ref. DDG-710211

Ref. DDG-710231

Ref. DDG-710207

Ref. DDG-710210

Ref. DDG-710226

Ref. DDG-710273

Ref. DDG-710221

Ref. DDG-710230

Ref. DDG-710265

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

• Implant Replica.• Exact.• For duplicate the shape and position of the implant platform.• Made in Stainless steel.

• For cemented resto-rations. Engaging.• Zirconium High Aesthetics.• With Titanium Interface. • High Precision. • High Strength.• Made in CIP zirconia. • Made in Titanium 5 grade.• Interfaces Anodized.

• Used for bridge abut-ment and crown.• Engaging.• Type A• High Quality.• High Strength.• DDG-710270-15º• DDG-710271-20º• DDG-710272-25º• Made in titanium 5 grade.

• Cast component.• Engaging. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

•For screw-cement reteined restorations. • Engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

•for allow gingival tisseus to heal prior to the placement abutment and maintain proper spacing in the oral cavity. • DDG-710207-0mm• DDG-710208-1.5mm• DDG-710251-3mm• DDG-710209-4.5mm• Made in Titanium 5 grade.

• Cast component.• Non engaging. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

• For cemented resto-rations. Engaging.• Zirconium High Aesthetics.• With Titanium Interface. • High Precision. • High Strength.• Made in CIP zirconia. • Made in Titanium 5 grade.• Interfaces Anodized.

• Used for bridge abut-ment and crown.• Engaging.• Type B.• High Quality.• High Strength.• DDG-710273-15º• DDG-710274-20º• DDG-710275-25º• Made in titanium 5 grade.

• Used for bridge abut-ment and crown.• Engaging.• High Quality.• High Strength.• Made in titanium 5 grade.

•For screw-cement reteined restorations. • Non engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

•For screw reteined restorations. • Engaging• High Precision.• Made in Titanium 5 grade.

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

Page 122: Catalog DDG-Components 2013 (v 8 2013)

Straumann® Tissue Level® 4.8 (Ref.DDG-7103) Part. 2

DDG-7100 System

Page 123: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

123www.ddg-scanlab.com

Castable shoulder

Titanium Temporaryabutment

Screw

Non Engagingcastable abutment

Scanbody InterfacesNon engaging

Screw

Engagingcastable abutment

Scanbody InterfacesEngaging (IntraOral)

Castable chimmey

Locator abutment

ScanBody DirectEngaging

Ref. DDG-710289

Ref. DDG-710229

Ref. DDG-710211

Ref. DDG-710218

Ref. DDG-710240

Ref. DDG-710210

Ref. DDG-710219

Ref. DDG-710241

Ref. DDG-710221

Ref. DDG-710230

Ref. DDG-710243

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

• Cast component.• Engaging. • For create a custom abutment.• Cnc Machined.• DDG-710289-S SIZE• DDG-710216-M SIZE• DDG-710217-L SIZE• Made in Delrin Plastic.

• Used for Temporary.• Engaging.• High Quality.• High Strength.• For SynOcta System. • Made in titanium 5 grade.

• For fixation of the restoration.• For SynOcta System. • High Quality.• High Strength.• Made in titanium 5 grade.

• Cast component.• Engaging. • For create a custom abutment.• For SynOcta System. • Cnc Machined.• Made in Delrin Plastic.

• For scan Implant position. Titanium.• Non Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

• For fixation of the restoration.• Normal type.. • High Quality.• High Strength.• Made in titanium 5 grade.

• Cast component.• Engaging. • For create a custom abutment.• For SynOcta System. • Cnc Machined.• Made in Delrin Plastic.

• For scan Implant position. Titanium.• Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

• Cast component.• For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

• Abutment for Overdentadures. • High accuracy.• Screw reteined.• Made in Titanium 5 grade.

• For scan Implant position. Titanium.• High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

D D G - C o m p o n e n t s

Page 124: Catalog DDG-Components 2013 (v 8 2013)

Straumann® Tissue Level® 4.8 SynOcta (Ref.DDG-7103)

DDG-7100 System

Page 125: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s

125www.ddg-scanlab.com

ScanBody DirectEngaging

Ref. DDG-710243

Technical Specifications

• For scan Implant position. Titanium.• High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Abutment Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

Page 126: Catalog DDG-Components 2013 (v 8 2013)

Straumann® Tissue Level® 6.0 (Ref.DDG-7104)

DDG-7100 System

Page 127: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s

127www.ddg-scanlab.com

ScanBody DirectEngaging

Ref. DDG-710343

Technical Specifications

• For scan Implant position. Titanium.• High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Abutment Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

Page 128: Catalog DDG-Components 2013 (v 8 2013)

Straumann® Tissue Level® 6.0 SynOcta (Ref.DDG-7105)

DDG-7100 System

Page 129: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s

129www.ddg-scanlab.com

ScanBody DirectEngaging

Ref. DDG-710543

Technical Specifications

• For scan Implant position. Titanium.• High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Abutment Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

Page 130: Catalog DDG-Components 2013 (v 8 2013)

Camlog® Screw Line ® 3.3 (Ref.DDG-7201)

DDG-7200 System

Page 131: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s

131www.ddg-scanlab.com

ScanBody Direct75 Engaging

Ref. DDG-720143

Technical Specifications

• For scan Implant position. Titanium.• High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

Page 132: Catalog DDG-Components 2013 (v 8 2013)

Camlog® Screw Line ® 3.8 (Ref.DDG-7202)

DDG-7200 System

Page 133: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s

133www.ddg-scanlab.com

ScanBody DirectEngaging

Ref. DDG-720243

Technical Specifications

• For scan Implant position. Titanium.• High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

Page 134: Catalog DDG-Components 2013 (v 8 2013)

Camlog® Screw Line ® 4.3 (Ref.DDG-7203)

DDG-7200 System

Page 135: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s

135www.ddg-scanlab.com

ScanBody Direct Engaging

Ref. DDG-720343

Technical Specifications

• For scan Implant position. Titanium.• High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

Page 136: Catalog DDG-Components 2013 (v 8 2013)

Camlog® Screw Line ® 5.0 (Ref.DDG-7204)

DDG-7200 System

Page 137: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s

137www.ddg-scanlab.com

ScanBody Direct Engaging

Ref. DDG-720443

Technical Specifications

• For scan Implant position. Titanium.• High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

Page 138: Catalog DDG-Components 2013 (v 8 2013)

Camlog® Screw Line ® 6.0 (Ref.DDG-7205)

DDG-7200 System

Page 139: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s

139www.ddg-scanlab.com

ScanBody DirectEngaging

Ref. DDG-720543

Technical Specifications

• For scan Implant position. Titanium.• High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

Page 140: Catalog DDG-Components 2013 (v 8 2013)

Camlog® Screw Line ® Bar Abutment (Ref.DDG-7206)

DDG-7200 System

Page 141: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s

141www.ddg-scanlab.com

ScanBody DirectNon Engaging

Ref. DDG-720643

Technical Specifications

• For scan Implant position. Titanium.• High Accuracy.• Non engaging.• Only for Bridge.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

Page 142: Catalog DDG-Components 2013 (v 8 2013)

Straumann® Bone Level® 3.3 (Ref.DDG-8101)

DDG-8100 System

Page 143: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

ScanBody DirectNon Engaging

ScanBody DirectEngaging

Ref. DDG-810142

Technical Specifications

• For scan Implant position. • High Accuracy.• Special Edition.• Non Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

143www.ddg-scanlab.com

Analog

Straight Zrabutment 1 mm

Scanbody InterfacesEngaging (IntraOral)

Engagingcastable abutment

Titanium engagingInterface

Non Engagingcastable abutment

Straight Zrabutment 2 mm

Scanbody InterfacesNon engaging

Screw

Titanium Non engaging Interface

Ref. DDG-810101

Ref. DDG-810125

Ref. DDG-810141

Ref. DDG-810111

Ref. DDG-810131

Ref. DDG-810110

Ref. DDG-810126

Ref. DDG-810140

Ref. DDG-810183

Ref. DDG-810130

Ref. DDG-810143

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

• Implant Replica.• Exact.• For duplicate the shape and position of the implant platform.• Made in Stainless steel.

• For cemented resto-rations. Engaging.• Zirconium High Aesthetics.• With Titanium Interface. • High Precision. • High Strength.• Made in CIP zirconia. • Made in Titanium 5 grade.• Interfaces Anodized.

• For scan Implant position. Titanium.• Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

• Cast component.• Engaging. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

•For screw-cement reteined restorations. • Engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

• Cast component.• Non engaging. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

• For cemented resto-rations. Engaging.• Zirconium High Aesthetics.• With Titanium Interface. • High Precision. • High Strength.• Made in CIP zirconia. • Made in Titanium 5 grade.• Interfaces Anodized.

• For scan Implant position. Titanium.• Non Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

• For fixation of the restoration.• Normal type.. • High Quality.• High Strength.• Made in titanium 5 grade.

•For screw-cement reteined restorations. • Non engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

• For scan Implant position. Titanium.• High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

Page 144: Catalog DDG-Components 2013 (v 8 2013)

Straumann® Bone Level® 4.1 (Ref.DDG-8102) Part 1

DDG-8100 System

Page 145: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

D D G - C o m p o n e n t s D D G - C o m p o n e n t sD D G - C o m p o n e n t s

145www.ddg-scanlab.com

Analog

Straight Zrabutment 1 mm

Engagingcastable abutment

Titanium engagingInterface

Non Engagingcastable abutment

Straight Zrabutment 2 mm

Screw

Titanium Non engaging Interface

Ref. DDG-810201

Ref. DDG-810225

Ref. DDG-810211

Ref. DDG-810231

Ref. DDG-810210

Ref. DDG-810226

Ref. DDG-810183

Ref. DDG-810230

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

Technical Specifications

• Implant Replica.• Exact.• For duplicate the shape and position of the implant platform.• Made in Stainless steel.

• For cemented resto-rations. Engaging.• Zirconium High Aesthetics.• With Titanium Interface. • High Precision. • High Strength.• Made in CIP zirconia. • Made in Titanium 5 grade.• Interfaces Anodized.

• Cast component.• Engaging. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

•For screw-cement reteined restorations. • Engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

• Cast component.• Non engaging. • For create a custom abutment.• Cnc Machined.• Made in Delrin Plastic.

• For cemented resto-rations. Engaging.• Zirconium High Aesthetics.• With Titanium Interface. • High Precision. • High Strength.• Made in CIP zirconia. • Made in Titanium 5 grade.• Interfaces Anodized.

• For fixation of the restoration.• Normal type.. • High Quality.• High Strength.• Made in titanium 5 grade.

•For screw-cement reteined restorations. • Non engaging• High Precision.• Interfaces Anodized.• Made in Titanium 5 grade.

D D G - C o m p o n e n t s

D D G - C o m p o n e n t s

Page 146: Catalog DDG-Components 2013 (v 8 2013)

Straumann® Bone Level® 4.1 (Ref.DDG-8102) Part 2

DDG-8100 System

Page 147: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s D D G - C o m p o n e n t s

147www.ddg-scanlab.com

Scanbody InterfacesEngaging (IntraOral)

ScanBody DirectNon Engaging

Scanbody InterfacesNon engaging

Titanium Estheticabutment

ScanBody DirectEngaging

Ref. DDG-810241 Ref. DDG-810242Ref. DDG-810240

Ref. DDG-810230

Ref. DDG-810243

Technical Specifications Technical SpecificationsTechnical Specifications

Technical Specifications

Technical Specifications

• For scan Implant position. Titanium.• Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

• For scan Implant position. • High Accuracy.• Special Edition.• Non Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

• For scan Implant position. Titanium.• Non Engaging.• For use in Laboratory and IntrOral.• On Titanium Inter-faces.• Compatible for all Cad system.•Not necessary spray.(90% of cases).

• Used for bridge abut-ment and crown.• Engaging.• High Quality.• High Strength.• Made in titanium 5 grade.

• For scan Implant position. Titanium.• High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

D D G - C o m p o n e n t s

Page 148: Catalog DDG-Components 2013 (v 8 2013)

Dentsply Friadent Ankylos® Implant Level® (Ref.DDG-8201)

DDG-8200 System

Page 149: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s

149www.ddg-scanlab.com

ScanBody Direct Engaging

Ref. DDG-820143

Technical Specifications

• For scan Implant position. Titanium.• High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

ScanBody DirectNon Engaging

Ref. DDG-820142

Technical Specifications

• For scan Implant position. Titanium.• High Accuracy.• NonEngaging.• Only for Bridge.• For use in Laboratory and IntraOral.• Implant Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

D D G - C o m p o n e n t s

Page 150: Catalog DDG-Components 2013 (v 8 2013)

Dentsply Friadent Ankylos® Abutment Level® (Ref.DDG-8202)

DDG-8200 System

Page 151: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s

151www.ddg-scanlab.com

ScanBody DirectNon Engaging

Ref. DDG-820243

Technical Specifications

• For scan Implant position. Titanium.• High Accuracy.• Non engaging.• For use in Laboratory and IntraOral.• Abutment Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

Page 152: Catalog DDG-Components 2013 (v 8 2013)

BioHorizons® Internal® 3.5 (Ref.DDG-9101)

DDG-9100 System

Page 153: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s

153www.ddg-scanlab.com

ScanBody Direct Engaging

Ref. DDG-910143

Technical Specifications

• For scan Implant position. Titanium.• High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Abutment Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

Page 154: Catalog DDG-Components 2013 (v 8 2013)

BioHorizons® Internal® 4.5 (Ref.DDG-9102)

DDG-9100 System

Page 155: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s

155www.ddg-scanlab.com

ScanBody DirectEngaging

Ref. DDG-910243

Technical Specifications

• For scan Implant position. Titanium.• High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Abutment Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

Page 156: Catalog DDG-Components 2013 (v 8 2013)

BioHorizons® Internal® 5.7 (Ref.DDG-9103)

DDG-9100 System

Page 157: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s

157www.ddg-scanlab.com

ScanBody DirectEngaging

Ref. DDG-910343

Technical Specifications

• For scan Implant position. Titanium.• High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Abutment Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

Page 158: Catalog DDG-Components 2013 (v 8 2013)

Osstem® TS System® Mini (Ref.DDG-9201)

DDG-9200 System

Page 159: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s

159www.ddg-scanlab.com

ScanBody DirectEngaging

Ref. DDG-920143

Technical Specifications

• For scan Implant position. Titanium.• High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Abutment Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

Page 160: Catalog DDG-Components 2013 (v 8 2013)

Osstem® TS System® Regular (Ref.DDG-9202)

DDG-9200 System

Page 161: Catalog DDG-Components 2013 (v 8 2013)

D D G - C o m p o n e n t s

161www.ddg-scanlab.com

ScanBody DirectEngaging

Ref. DDG-920243

Technical Specifications

• For scan Implant position. Titanium.• High Accuracy.• Engaging.• For use in Laboratory and IntraOral.• Abutment Level.• Compatible for all Cad system.• Not necessary spray.(90% of cases).

Page 162: Catalog DDG-Components 2013 (v 8 2013)

Sales:[email protected]

Support:[email protected]

DDG-ComponentsP.O.Box #24 .11403Jerez de la Fra.Cá[email protected]