CAT-2010-08 Osseointegrated Fixtures Product …...implants allows us to provide Innovative...

16
Product Catalogue OSSEOINTEGRATED FIXTURES Version 8

Transcript of CAT-2010-08 Osseointegrated Fixtures Product …...implants allows us to provide Innovative...

Product CatalogueOSSEOINTEGRATED FIXTURES

Version 8

0202

Graham Blackbeard Managing Director Southern Implants

Striving for excellence and meeting customer needs has led to our wide product range characterized by Unique and Innovative products which include

TM- INVERTA implant featuring a body-shift design engineered for primary stability and suitable for immediate loading

reg- Co-Axis sub-crestal angle correcting implant available in angulations of 12 24 amp 36deg and various internal and external connections

- MAX implant specifically designed for immediate molar tooth replacement- The ZYGAN and ZYGEX implants for severely resorbed maxilla and craniofacial reconstruction

- Multiple interfaces to suit customer preference

Southern Implants is a leading provider of unique and innovative dental implant products with a focus on top-end professional users who want more choices Southerns expertise in research development and manufacturing of dental implants allows us to provide Innovative Treatment Solutions that will reduce treatment times and improve patient outcomes

My sincere thanks to all specialists dentists and technicians who put their trust in our company

Our product portfolio is in synchronized evolution with protocol improvements and technological advances

Prosthetic FlowchartProsthetic Flowchart

Magnetic Retention Steco Titanmagnetics for IE

Site Preparation Sequence (Parallel walled amp Tapered implants)

Surgical TrayI-EO-EG

Steco Titanmagnetics

External Hex Ultra-Short Oslash375mm Oslash45mm Implant

Implant dimensions and Information

Instrumentation (Parallel walled amp Tapered implants)

Driver and Screw Information

Implants amp Surgical Components

Explanation of Symbols

CONTENTS

03

Page 06Page 07Page 07Page 08

Page 12

Page 10

Page 12

Page 09

Page 14

Page 15

Further information available on our websiteSOUTHERNIMPLANTSCOM

reg

04

Images are for illustration purposes only and do not necessarily accurately represent the productNOTE

Not all products are cleared for sale in all countries

All dimensions in this catalogue are in mm unless otherwise specified

05

EXTERNAL HEX

Oslash375mm Oslash45mm

ULTRA-SHORT

06

Implant dimensions and information - page 14

Implant dimensions and information - page 14

IE 4 6

IE 3

Implants are available in lengths of

Implants are available in lengths of

SCU2

SC4

IE3

234568lengths

234568lengths

Oslash45 Oslash55

WBTB

3mm

IET 4

IETi 4

IE4 IE6

41mm4mm

6mm

41mm

IET4 IET 4i(Internal Drive)

Item code

Item code

Implant lengths (in mm)

Implant lengths (in mm)

Item code Implant lengths (in mm)

Cylindrical

Cylindrical

Tapered

(Internal Drive)

8length

Oslash45

TBE8n

Cover Screw Healing Abutments

Surgical Components

Cover Screw Healing Abutments

Surgical Components

Oslash375mm Oslash45mm Implants Oslash375mm Oslash45mm Implants (Parallel Walled amp Tapered)(Parallel Walled amp Tapered)Oslash375mm Oslash45mm Implants (Parallel Walled amp Tapered)

Oslash375mm Implants Oslash375mm Implants (Parallel Walled)(Parallel Walled)Oslash375mm Implants (Parallel Walled)

07

SC4

IE3

TBE8n

WB

TB

StandardAbutment

HealingAbutment

Impression Coping

Laboratory Analogue

Prosthetic Components

Retaining Screws

CB1(PICK-UP)

3 4 55 7 85 10

ABE LS1

1 Series Screws

GoldGold

GCP3GCP3

Titanium

TC9

SCU2

IET4

IET 4i

IE6

IE4

Prosthetic FlowchartProsthetic FlowchartProsthetic Flowchart

Prosthetic FlowchartProsthetic FlowchartProsthetic Flowchart

IE6

IE4

IE3 I0201Z475I0201Z600I0201Z700I0201Z800 A0002Z695 M0001Z1000

475 6 7 8 with collar

U0001Z315KU0001Z315

for acrylic prostheses

U0002Z315K

with collar

Z-Line (wide spherical abutment)

I0201T520I0201T720 E0004T1 A0002T750 M0001T1050

52 72

U0001T570

for acrylic prostheses

U0002T570

for silcone prostheses

X-Line (standard spherical abutment)

AbutmentsLaboratory Analogues Magneto

I0201X350I0201X500I0201X650I0201X800 E0004X1 M0001X900

35 5 65 8

for silcone prostheses

U0002Z315

U0002X265

for silcone prostheses

U0002X265K

with collar

U0001X265R

for acrylic prostheses

U0001X265K

with collar

A0001X555

Orbita

A0002X265

Auricular Nasal

T-Line (Telescopic abutment)

reg Magnetic Retention Steco Titanmagnetics for IE

OslashNOTE See page 20-23 for more information on Steco Titanmagnetics prosthetics and instrumentation

08

Medium Bone

Oslash375mm Parallel Walled (IE3) 3mm length

4mm length

6mm length

Oslash20mm

Oslash30mm

D-RB-M

S

Medium Bone

Oslash375mm Parallel Walled (IE4)

Oslash20mm

Oslash30mm

D-RB-M

S

Oslash375mm Parallel Walled (IE6)

Soft Bone

Oslash20mm

D-RB-M

S

Soft Bone

Oslash20mm

D-RB-M

S

Soft Bone

Oslash20mm

D-RB-M

S

Dense Bone

Oslash20mm

Oslash30mm

D-RB-M

S

Dense Bone

Oslash20mm

Oslash30mm

D-RB-M

S

Medium Bone

Oslash20mm

Oslash30mm

D-RB-M

S

Dense Bone

Oslash20mm

Oslash30mm

D-RB-M

S

D-TAP-IB

S

D-TAP-IB

S

D-TAP-IB

S

Medium Bone

Oslash40mm Tapered (IET4 IET 4)i

Soft Bone

Oslash20mm

D-RB-M

S

Dense Bone

Oslash20mm

Oslash40mm

D-RB-M

S

Oslash20mm

Oslash40mm

D-RB-M

S

NOTE The total implant length is reached when the flange of the 4mm tapered drill touches the bone surface Drilling beyond this point may compromise primary stability of the implant

4mm length

Site Preparation SequenceSite Preparation SequenceSite Preparation Sequence

IET4

09

Most instruments are available in various lengths

IET 4i

I-WI-CST I-WI-SS

(Internal Drive)

Oslash45mm Tapered (IETi4)

INSTRUMENTATION

Wrench Converters

Wrench Converters

Insertion Tools

I-HIDU-S M L I-WIID-S LI-HID-S M L

Handpiece InsertUniversal

Wrench InsertHandpiece Insertwith WampH

I-WI-CST I-WI-SH

IE4IE3 IE6

Fixture Mounted Implants (Parallel Walled amp Tapered)

Internal Drive Implant (Tapered)

Insertion Tools

I-CON-X

Fixture Mount Driver

(With WampH)

Fixture Mount Universal Driver(Without WampH)

I-CONU-X

For Handpiece inserts (Latch-type)

featuring the WampH hex

For HEX connection of fixture mounts

For Handpiece inserts (Latch-type) featuring the WampH hex

For SQUARE connection of fixture mounts

and instruments

PLACEMENT TOOLS DRILLS DRIVERS

10

IE3

IE4

IE6

IET

I-EO-EG For surgical placement of Extraoral ImplantsI-EO-EG

INSTRUMENT TRAY

Pilot DrillD-RB-MS

Oslash20mmTwist Drills

Final Twist Drills

Final Tapered Drill

Placement Tools

D-20E-03F

D-20E-04F

D-20E-06F

D-30E-03F

D-30E-04F

D-30E-06F

D-40E-04F

I-CON-X XS

I-CONU-X XS

Handpiece Insert

Convert latch type instrument with the WampH hex to fit with square connection

Torque wrench

Converter

Drill Extensions

I-WI-C-S L

I-DE-G

I-DE-K

(Optional)

Bone Tap

D-TAP-IBS

(Optional)

I-WI-AWrench Insert

Standard Abutment Drivers(Hex)

I-AD

I-HAD

Handheld

Handpiece Insert

I-HID-S M L

Internal Drive

Handpiece Insert

I-WIID-S LInternal Drive

Wrench Insert

Hex Drivers (122mm)

I-HD-SMLHandheld

I-HHD-22SMLHandpiece Insert

I-WI-22SMLWrench Insert

Cover Screw Drivers(09mm)

I-CS-HD L

I-HHD-09

I-WI-09

09mm Hex

Handheld

Handpiece Insert

Wrench Insert

11

Flat Spanner

I-SP-X (System specific)

I-TWS-B45 I-TWS-B100

I-TWS

Wrench Torque Attachments

Wrench Converters

I-WI-CST

For Handpiece inserts (Latch-type)

featuring the WampH hex

I-WI-SL

For Handpiece inserts (Latch-type)

without the WampH hex

I-WI-SS

For SQUARE connection of fixture mounts

and instruments

I-WI-SH

For HEX connection of fixture mounts

All instruments and tooling used during the procedure must be maintained in good condition and cleaned and sterilized prior to to use Please consult the Southern Implants

Cleaning and Sterilization Procedure Guidelines (CAT-1039) for guidance concerning the maintenance of drills instruments and surgical trays

NOTE

Most Instruments available in Short Medium Long

The surgical kit has an intuitive layout to guide the surgeon through the drill sequence

For Polishing Protector Caps refer to CAT-1010

12

NOTE Refer to CAT-1203 for alternative drivers

UNIVERSAL 122127 UNIVERSAL 122127UNIVERSAL 122127

HANDHELD HANDPIECE WRENCH

I-HD-SML

122 122122

I-HHD-22SML I-WI-22SMLI-HHD-22U-SMLI-HD-22U-SML I-WI-22U-SML

DRIVER AND SCREW INFORMATION

I-UGI-SML I-HUG-SML I-WI-UG-SML

UNIGRIP Drivers

Alternative Drivers

Hex Drivers

Laboratory Screw

1 Series Screws

TORQUE 10-15Ncm

Head Diameter 225mm

122 Hex 122 HexUnigrip

TSH1GSH1

TSU1GSU1 (Blackened and for

laboratory use only)

BSH1

NOTE bull Due to design revisions screw tips may be flat or rounded

bull Always ensure that the correct screw is used for the relevant implant and component

Screw Head Connections

Hex Unigrip

STECO TITANMAGNETICS

Dual magnet system The construction principle

Sm2Co1

7 Magnet

Implant-specific geometry

Corrosion-proof titanium housing

Prostheses magnet

Insert Attachment

Magnetic attachments for facial prosthesis

The universal and easily manageable solution for implant-supported face prostheses and obturators

bull Refer to CAT-1003 for alternative slotted 1 Series screws

Two open magnet fields exert a force of attraction over a longer distance than mono-magnet systems

13

STECO TITANMAGNETICS

Oslash480 Oslash580

Height

265 mmHeight

315 mmProstheses magnet

Insert Attachment

30 N (300 g)Withdrawal force16 N (163 g)

X-Line Z-Line

reg The slightly curved surface of the spherical StecoTitanmagnetics X-Line and the Z-Line facilitates self centering and has the lowest lateral force introduction into the implant X-Line and Z-Line are therefore particularly suitable for short implants Due to the absence of lateral steering they are also indicated for highly divergent implants

Spherical magnets

T-Line

reg The StecoTitanmagnetics T-Line was developed exclusively for extraoral use The telescopic bearing of 25 mm gives the facial prosthesis secure fixation on the tissue The design allows a certain amount of rotation and axial movement without losing the withdrawal force

Telescopic magnets

Oslash580

Distance height

Distance height

Distance height

Height

57 mm

14 N (143 g)

Prosthesis magnet

Withdrawal force

Insert Attachment

Prosthetic Components

In X-Line and Z-Line there are prostheses magnets for acrylic and with additional retention for silicone For more lateral support there are prostheses magnets with extended collars available

For silicone

with collar and retention ring

with retention ring with rotation protection with collar

For acrylicFor silicone For acrylic

Universalwith retention ring

In the T-Line there are also prostheses magnets for acrylic and with additional retention for silicone

Accessories

To make a new prostheses each product line has its own compatible impression copings and laboratory analogues

Impression Copings- magnetic impression without screws- lock magnetically to the insert- the external geometry ensures the impression material is securely fi xed

Z-Line T-LineX-Line

Laboratory Analogues- for making models quickly and hygienically- the original implant does not have to be used on the insertion point of an analogue

- there is no need for time-consuming cleaning- a length of 16 mm is also available on request

Z-Line T-LineX-Line

The Healing-Flange is placed on the insert to stabilize the bandage on fresh skin perforation tissue after application of the insert This minimizes excessive tissue proliferation The Healing-Flange has its own magnet core and is made off tissue friendly Titanium

Healing Flange

X-Line T-Line

Insertion standard tools

X-Line

H0004X2

Connector to handpiece

H0004X4

H0004X1

Connector to ratchet

Z-Line amp T-Line

H0004T2

Connector to handpiece

Connector to ratchet

H0004T4

H0004T1

Connector to I-Ratchet-2Connector to I-Ratchet-2

14

APEXDIAMETER

PLATFORM DIAMETER

PLATFORM DIAMETER (flange)

MAJOR DIAMETER

COLLAR HEIGHT

THREADPITCH

APEXDIAMETER

THREADPITCH

COLLAR HEIGHT

HEXHEIGHT

HEXWIDTH

ProstheticColourCode

PLATFORM DIAMETER

(flange)

MAJOR DIAMETER

IE

IET

IETi

375

45

45

480

407

407

270

270

270

040 280

245

245

Cylindricalor Tapered

CT 63 4

radic

radic

radic

radic radic06

05

05

025

025

07

07

07

C

T

T

Oslash375mm

Oslash45mm

Oslash45mm

RANGE IMPLANT LENGTHS

IMPLANT DIMENSIONS AND INFORMATION

The following symbols are used on our packaging labels and they indicate the following

1

3

4

6

7

6

AMERICAS ASIA Southern Implants North America Inc 225 Chimney Corner Lane Suite 3011 Jupiter FL 33458 United States of America

Southern Implants UK Ltd Building 3 Chiswick Park566 Chiswick High Road London W4 5YA United KingdomEC REP

1 Albert Rd IRENE 0062 South AfricaSouthern Implants (Pty) Ltd

22797

STERILIZE2

only

yyyy-mm

LOTLOT

5

IET4

IET4

IET4

Doc 0000-0 Rev 0

IET4

REF

REF

REF

REF

(01) 00000000000000(17) Date packed(10) Expiry Date

Ext Hex Tapered Implant Ultra-Short Oslash45 x 4mm

Oslash45 x 4mm Oslash45 x 4mm

Manufacturer1

2

3

4

7

55

6

STERILE R

Implant details and size

Implant image

Sterilization using Irradiation

Caution

CE mark and notified body number

Expiry date

Prescription device

ii

STERILE R

22

STERILIZE2

STERILIZE2 Do not Resterilize

Consult instruction for use

Do not reuse

Sterile unless package is opened or damaged

CAUTION FEDERAL LAW RESTRICTS THE DEVICE TO SALE BY OR ON THE ORDER OF A LICENCED HEALTH CARE PROVIDER

Patient sticker for documentation purposes(to be used by health care provider on patient file)

2D Bar codingContains the GTIN Expiry Date and LOT Number

EXPLANATION OF SYMBOLS

15

copy2019 Southern Implants (Pty) Ltd All rights reserved Co-Axis Southern Implantsand Subcrestal Angle Correctionare registered trademarks and Body-Shift INVERTA and PROVATA are trademarks of Southern Implants (Pty) Ltd Not all implants are available in all markets

CAT-2010-08 (C1073)

For more information please contact your Southern Implants Representative or visit southernimplantscom

Subsidiaries

AustraliaSouthern Implants AustraliaT +61-2-8076-9337E infosouthernimplantscomau

United KingdomSouthern Implants UKT +44-20-8899-6845 6 7E infosouthernimplantscouk

USA and CanadaSouthern Implants North America IncT +1-561-472-0990E customercaresouthernimplantscom

South Africa ndash Headquarters 1 Albert Road Irene RSAT +27-12-667-1046 | E infosouthernimplantscom

Southern Implants Products are distributed world-wide please visit southernimplantscom for a list of Distributors

  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • Page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Page 15
  • Page 16

0202

Graham Blackbeard Managing Director Southern Implants

Striving for excellence and meeting customer needs has led to our wide product range characterized by Unique and Innovative products which include

TM- INVERTA implant featuring a body-shift design engineered for primary stability and suitable for immediate loading

reg- Co-Axis sub-crestal angle correcting implant available in angulations of 12 24 amp 36deg and various internal and external connections

- MAX implant specifically designed for immediate molar tooth replacement- The ZYGAN and ZYGEX implants for severely resorbed maxilla and craniofacial reconstruction

- Multiple interfaces to suit customer preference

Southern Implants is a leading provider of unique and innovative dental implant products with a focus on top-end professional users who want more choices Southerns expertise in research development and manufacturing of dental implants allows us to provide Innovative Treatment Solutions that will reduce treatment times and improve patient outcomes

My sincere thanks to all specialists dentists and technicians who put their trust in our company

Our product portfolio is in synchronized evolution with protocol improvements and technological advances

Prosthetic FlowchartProsthetic Flowchart

Magnetic Retention Steco Titanmagnetics for IE

Site Preparation Sequence (Parallel walled amp Tapered implants)

Surgical TrayI-EO-EG

Steco Titanmagnetics

External Hex Ultra-Short Oslash375mm Oslash45mm Implant

Implant dimensions and Information

Instrumentation (Parallel walled amp Tapered implants)

Driver and Screw Information

Implants amp Surgical Components

Explanation of Symbols

CONTENTS

03

Page 06Page 07Page 07Page 08

Page 12

Page 10

Page 12

Page 09

Page 14

Page 15

Further information available on our websiteSOUTHERNIMPLANTSCOM

reg

04

Images are for illustration purposes only and do not necessarily accurately represent the productNOTE

Not all products are cleared for sale in all countries

All dimensions in this catalogue are in mm unless otherwise specified

05

EXTERNAL HEX

Oslash375mm Oslash45mm

ULTRA-SHORT

06

Implant dimensions and information - page 14

Implant dimensions and information - page 14

IE 4 6

IE 3

Implants are available in lengths of

Implants are available in lengths of

SCU2

SC4

IE3

234568lengths

234568lengths

Oslash45 Oslash55

WBTB

3mm

IET 4

IETi 4

IE4 IE6

41mm4mm

6mm

41mm

IET4 IET 4i(Internal Drive)

Item code

Item code

Implant lengths (in mm)

Implant lengths (in mm)

Item code Implant lengths (in mm)

Cylindrical

Cylindrical

Tapered

(Internal Drive)

8length

Oslash45

TBE8n

Cover Screw Healing Abutments

Surgical Components

Cover Screw Healing Abutments

Surgical Components

Oslash375mm Oslash45mm Implants Oslash375mm Oslash45mm Implants (Parallel Walled amp Tapered)(Parallel Walled amp Tapered)Oslash375mm Oslash45mm Implants (Parallel Walled amp Tapered)

Oslash375mm Implants Oslash375mm Implants (Parallel Walled)(Parallel Walled)Oslash375mm Implants (Parallel Walled)

07

SC4

IE3

TBE8n

WB

TB

StandardAbutment

HealingAbutment

Impression Coping

Laboratory Analogue

Prosthetic Components

Retaining Screws

CB1(PICK-UP)

3 4 55 7 85 10

ABE LS1

1 Series Screws

GoldGold

GCP3GCP3

Titanium

TC9

SCU2

IET4

IET 4i

IE6

IE4

Prosthetic FlowchartProsthetic FlowchartProsthetic Flowchart

Prosthetic FlowchartProsthetic FlowchartProsthetic Flowchart

IE6

IE4

IE3 I0201Z475I0201Z600I0201Z700I0201Z800 A0002Z695 M0001Z1000

475 6 7 8 with collar

U0001Z315KU0001Z315

for acrylic prostheses

U0002Z315K

with collar

Z-Line (wide spherical abutment)

I0201T520I0201T720 E0004T1 A0002T750 M0001T1050

52 72

U0001T570

for acrylic prostheses

U0002T570

for silcone prostheses

X-Line (standard spherical abutment)

AbutmentsLaboratory Analogues Magneto

I0201X350I0201X500I0201X650I0201X800 E0004X1 M0001X900

35 5 65 8

for silcone prostheses

U0002Z315

U0002X265

for silcone prostheses

U0002X265K

with collar

U0001X265R

for acrylic prostheses

U0001X265K

with collar

A0001X555

Orbita

A0002X265

Auricular Nasal

T-Line (Telescopic abutment)

reg Magnetic Retention Steco Titanmagnetics for IE

OslashNOTE See page 20-23 for more information on Steco Titanmagnetics prosthetics and instrumentation

08

Medium Bone

Oslash375mm Parallel Walled (IE3) 3mm length

4mm length

6mm length

Oslash20mm

Oslash30mm

D-RB-M

S

Medium Bone

Oslash375mm Parallel Walled (IE4)

Oslash20mm

Oslash30mm

D-RB-M

S

Oslash375mm Parallel Walled (IE6)

Soft Bone

Oslash20mm

D-RB-M

S

Soft Bone

Oslash20mm

D-RB-M

S

Soft Bone

Oslash20mm

D-RB-M

S

Dense Bone

Oslash20mm

Oslash30mm

D-RB-M

S

Dense Bone

Oslash20mm

Oslash30mm

D-RB-M

S

Medium Bone

Oslash20mm

Oslash30mm

D-RB-M

S

Dense Bone

Oslash20mm

Oslash30mm

D-RB-M

S

D-TAP-IB

S

D-TAP-IB

S

D-TAP-IB

S

Medium Bone

Oslash40mm Tapered (IET4 IET 4)i

Soft Bone

Oslash20mm

D-RB-M

S

Dense Bone

Oslash20mm

Oslash40mm

D-RB-M

S

Oslash20mm

Oslash40mm

D-RB-M

S

NOTE The total implant length is reached when the flange of the 4mm tapered drill touches the bone surface Drilling beyond this point may compromise primary stability of the implant

4mm length

Site Preparation SequenceSite Preparation SequenceSite Preparation Sequence

IET4

09

Most instruments are available in various lengths

IET 4i

I-WI-CST I-WI-SS

(Internal Drive)

Oslash45mm Tapered (IETi4)

INSTRUMENTATION

Wrench Converters

Wrench Converters

Insertion Tools

I-HIDU-S M L I-WIID-S LI-HID-S M L

Handpiece InsertUniversal

Wrench InsertHandpiece Insertwith WampH

I-WI-CST I-WI-SH

IE4IE3 IE6

Fixture Mounted Implants (Parallel Walled amp Tapered)

Internal Drive Implant (Tapered)

Insertion Tools

I-CON-X

Fixture Mount Driver

(With WampH)

Fixture Mount Universal Driver(Without WampH)

I-CONU-X

For Handpiece inserts (Latch-type)

featuring the WampH hex

For HEX connection of fixture mounts

For Handpiece inserts (Latch-type) featuring the WampH hex

For SQUARE connection of fixture mounts

and instruments

PLACEMENT TOOLS DRILLS DRIVERS

10

IE3

IE4

IE6

IET

I-EO-EG For surgical placement of Extraoral ImplantsI-EO-EG

INSTRUMENT TRAY

Pilot DrillD-RB-MS

Oslash20mmTwist Drills

Final Twist Drills

Final Tapered Drill

Placement Tools

D-20E-03F

D-20E-04F

D-20E-06F

D-30E-03F

D-30E-04F

D-30E-06F

D-40E-04F

I-CON-X XS

I-CONU-X XS

Handpiece Insert

Convert latch type instrument with the WampH hex to fit with square connection

Torque wrench

Converter

Drill Extensions

I-WI-C-S L

I-DE-G

I-DE-K

(Optional)

Bone Tap

D-TAP-IBS

(Optional)

I-WI-AWrench Insert

Standard Abutment Drivers(Hex)

I-AD

I-HAD

Handheld

Handpiece Insert

I-HID-S M L

Internal Drive

Handpiece Insert

I-WIID-S LInternal Drive

Wrench Insert

Hex Drivers (122mm)

I-HD-SMLHandheld

I-HHD-22SMLHandpiece Insert

I-WI-22SMLWrench Insert

Cover Screw Drivers(09mm)

I-CS-HD L

I-HHD-09

I-WI-09

09mm Hex

Handheld

Handpiece Insert

Wrench Insert

11

Flat Spanner

I-SP-X (System specific)

I-TWS-B45 I-TWS-B100

I-TWS

Wrench Torque Attachments

Wrench Converters

I-WI-CST

For Handpiece inserts (Latch-type)

featuring the WampH hex

I-WI-SL

For Handpiece inserts (Latch-type)

without the WampH hex

I-WI-SS

For SQUARE connection of fixture mounts

and instruments

I-WI-SH

For HEX connection of fixture mounts

All instruments and tooling used during the procedure must be maintained in good condition and cleaned and sterilized prior to to use Please consult the Southern Implants

Cleaning and Sterilization Procedure Guidelines (CAT-1039) for guidance concerning the maintenance of drills instruments and surgical trays

NOTE

Most Instruments available in Short Medium Long

The surgical kit has an intuitive layout to guide the surgeon through the drill sequence

For Polishing Protector Caps refer to CAT-1010

12

NOTE Refer to CAT-1203 for alternative drivers

UNIVERSAL 122127 UNIVERSAL 122127UNIVERSAL 122127

HANDHELD HANDPIECE WRENCH

I-HD-SML

122 122122

I-HHD-22SML I-WI-22SMLI-HHD-22U-SMLI-HD-22U-SML I-WI-22U-SML

DRIVER AND SCREW INFORMATION

I-UGI-SML I-HUG-SML I-WI-UG-SML

UNIGRIP Drivers

Alternative Drivers

Hex Drivers

Laboratory Screw

1 Series Screws

TORQUE 10-15Ncm

Head Diameter 225mm

122 Hex 122 HexUnigrip

TSH1GSH1

TSU1GSU1 (Blackened and for

laboratory use only)

BSH1

NOTE bull Due to design revisions screw tips may be flat or rounded

bull Always ensure that the correct screw is used for the relevant implant and component

Screw Head Connections

Hex Unigrip

STECO TITANMAGNETICS

Dual magnet system The construction principle

Sm2Co1

7 Magnet

Implant-specific geometry

Corrosion-proof titanium housing

Prostheses magnet

Insert Attachment

Magnetic attachments for facial prosthesis

The universal and easily manageable solution for implant-supported face prostheses and obturators

bull Refer to CAT-1003 for alternative slotted 1 Series screws

Two open magnet fields exert a force of attraction over a longer distance than mono-magnet systems

13

STECO TITANMAGNETICS

Oslash480 Oslash580

Height

265 mmHeight

315 mmProstheses magnet

Insert Attachment

30 N (300 g)Withdrawal force16 N (163 g)

X-Line Z-Line

reg The slightly curved surface of the spherical StecoTitanmagnetics X-Line and the Z-Line facilitates self centering and has the lowest lateral force introduction into the implant X-Line and Z-Line are therefore particularly suitable for short implants Due to the absence of lateral steering they are also indicated for highly divergent implants

Spherical magnets

T-Line

reg The StecoTitanmagnetics T-Line was developed exclusively for extraoral use The telescopic bearing of 25 mm gives the facial prosthesis secure fixation on the tissue The design allows a certain amount of rotation and axial movement without losing the withdrawal force

Telescopic magnets

Oslash580

Distance height

Distance height

Distance height

Height

57 mm

14 N (143 g)

Prosthesis magnet

Withdrawal force

Insert Attachment

Prosthetic Components

In X-Line and Z-Line there are prostheses magnets for acrylic and with additional retention for silicone For more lateral support there are prostheses magnets with extended collars available

For silicone

with collar and retention ring

with retention ring with rotation protection with collar

For acrylicFor silicone For acrylic

Universalwith retention ring

In the T-Line there are also prostheses magnets for acrylic and with additional retention for silicone

Accessories

To make a new prostheses each product line has its own compatible impression copings and laboratory analogues

Impression Copings- magnetic impression without screws- lock magnetically to the insert- the external geometry ensures the impression material is securely fi xed

Z-Line T-LineX-Line

Laboratory Analogues- for making models quickly and hygienically- the original implant does not have to be used on the insertion point of an analogue

- there is no need for time-consuming cleaning- a length of 16 mm is also available on request

Z-Line T-LineX-Line

The Healing-Flange is placed on the insert to stabilize the bandage on fresh skin perforation tissue after application of the insert This minimizes excessive tissue proliferation The Healing-Flange has its own magnet core and is made off tissue friendly Titanium

Healing Flange

X-Line T-Line

Insertion standard tools

X-Line

H0004X2

Connector to handpiece

H0004X4

H0004X1

Connector to ratchet

Z-Line amp T-Line

H0004T2

Connector to handpiece

Connector to ratchet

H0004T4

H0004T1

Connector to I-Ratchet-2Connector to I-Ratchet-2

14

APEXDIAMETER

PLATFORM DIAMETER

PLATFORM DIAMETER (flange)

MAJOR DIAMETER

COLLAR HEIGHT

THREADPITCH

APEXDIAMETER

THREADPITCH

COLLAR HEIGHT

HEXHEIGHT

HEXWIDTH

ProstheticColourCode

PLATFORM DIAMETER

(flange)

MAJOR DIAMETER

IE

IET

IETi

375

45

45

480

407

407

270

270

270

040 280

245

245

Cylindricalor Tapered

CT 63 4

radic

radic

radic

radic radic06

05

05

025

025

07

07

07

C

T

T

Oslash375mm

Oslash45mm

Oslash45mm

RANGE IMPLANT LENGTHS

IMPLANT DIMENSIONS AND INFORMATION

The following symbols are used on our packaging labels and they indicate the following

1

3

4

6

7

6

AMERICAS ASIA Southern Implants North America Inc 225 Chimney Corner Lane Suite 3011 Jupiter FL 33458 United States of America

Southern Implants UK Ltd Building 3 Chiswick Park566 Chiswick High Road London W4 5YA United KingdomEC REP

1 Albert Rd IRENE 0062 South AfricaSouthern Implants (Pty) Ltd

22797

STERILIZE2

only

yyyy-mm

LOTLOT

5

IET4

IET4

IET4

Doc 0000-0 Rev 0

IET4

REF

REF

REF

REF

(01) 00000000000000(17) Date packed(10) Expiry Date

Ext Hex Tapered Implant Ultra-Short Oslash45 x 4mm

Oslash45 x 4mm Oslash45 x 4mm

Manufacturer1

2

3

4

7

55

6

STERILE R

Implant details and size

Implant image

Sterilization using Irradiation

Caution

CE mark and notified body number

Expiry date

Prescription device

ii

STERILE R

22

STERILIZE2

STERILIZE2 Do not Resterilize

Consult instruction for use

Do not reuse

Sterile unless package is opened or damaged

CAUTION FEDERAL LAW RESTRICTS THE DEVICE TO SALE BY OR ON THE ORDER OF A LICENCED HEALTH CARE PROVIDER

Patient sticker for documentation purposes(to be used by health care provider on patient file)

2D Bar codingContains the GTIN Expiry Date and LOT Number

EXPLANATION OF SYMBOLS

15

copy2019 Southern Implants (Pty) Ltd All rights reserved Co-Axis Southern Implantsand Subcrestal Angle Correctionare registered trademarks and Body-Shift INVERTA and PROVATA are trademarks of Southern Implants (Pty) Ltd Not all implants are available in all markets

CAT-2010-08 (C1073)

For more information please contact your Southern Implants Representative or visit southernimplantscom

Subsidiaries

AustraliaSouthern Implants AustraliaT +61-2-8076-9337E infosouthernimplantscomau

United KingdomSouthern Implants UKT +44-20-8899-6845 6 7E infosouthernimplantscouk

USA and CanadaSouthern Implants North America IncT +1-561-472-0990E customercaresouthernimplantscom

South Africa ndash Headquarters 1 Albert Road Irene RSAT +27-12-667-1046 | E infosouthernimplantscom

Southern Implants Products are distributed world-wide please visit southernimplantscom for a list of Distributors

  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • Page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Page 15
  • Page 16

Prosthetic FlowchartProsthetic Flowchart

Magnetic Retention Steco Titanmagnetics for IE

Site Preparation Sequence (Parallel walled amp Tapered implants)

Surgical TrayI-EO-EG

Steco Titanmagnetics

External Hex Ultra-Short Oslash375mm Oslash45mm Implant

Implant dimensions and Information

Instrumentation (Parallel walled amp Tapered implants)

Driver and Screw Information

Implants amp Surgical Components

Explanation of Symbols

CONTENTS

03

Page 06Page 07Page 07Page 08

Page 12

Page 10

Page 12

Page 09

Page 14

Page 15

Further information available on our websiteSOUTHERNIMPLANTSCOM

reg

04

Images are for illustration purposes only and do not necessarily accurately represent the productNOTE

Not all products are cleared for sale in all countries

All dimensions in this catalogue are in mm unless otherwise specified

05

EXTERNAL HEX

Oslash375mm Oslash45mm

ULTRA-SHORT

06

Implant dimensions and information - page 14

Implant dimensions and information - page 14

IE 4 6

IE 3

Implants are available in lengths of

Implants are available in lengths of

SCU2

SC4

IE3

234568lengths

234568lengths

Oslash45 Oslash55

WBTB

3mm

IET 4

IETi 4

IE4 IE6

41mm4mm

6mm

41mm

IET4 IET 4i(Internal Drive)

Item code

Item code

Implant lengths (in mm)

Implant lengths (in mm)

Item code Implant lengths (in mm)

Cylindrical

Cylindrical

Tapered

(Internal Drive)

8length

Oslash45

TBE8n

Cover Screw Healing Abutments

Surgical Components

Cover Screw Healing Abutments

Surgical Components

Oslash375mm Oslash45mm Implants Oslash375mm Oslash45mm Implants (Parallel Walled amp Tapered)(Parallel Walled amp Tapered)Oslash375mm Oslash45mm Implants (Parallel Walled amp Tapered)

Oslash375mm Implants Oslash375mm Implants (Parallel Walled)(Parallel Walled)Oslash375mm Implants (Parallel Walled)

07

SC4

IE3

TBE8n

WB

TB

StandardAbutment

HealingAbutment

Impression Coping

Laboratory Analogue

Prosthetic Components

Retaining Screws

CB1(PICK-UP)

3 4 55 7 85 10

ABE LS1

1 Series Screws

GoldGold

GCP3GCP3

Titanium

TC9

SCU2

IET4

IET 4i

IE6

IE4

Prosthetic FlowchartProsthetic FlowchartProsthetic Flowchart

Prosthetic FlowchartProsthetic FlowchartProsthetic Flowchart

IE6

IE4

IE3 I0201Z475I0201Z600I0201Z700I0201Z800 A0002Z695 M0001Z1000

475 6 7 8 with collar

U0001Z315KU0001Z315

for acrylic prostheses

U0002Z315K

with collar

Z-Line (wide spherical abutment)

I0201T520I0201T720 E0004T1 A0002T750 M0001T1050

52 72

U0001T570

for acrylic prostheses

U0002T570

for silcone prostheses

X-Line (standard spherical abutment)

AbutmentsLaboratory Analogues Magneto

I0201X350I0201X500I0201X650I0201X800 E0004X1 M0001X900

35 5 65 8

for silcone prostheses

U0002Z315

U0002X265

for silcone prostheses

U0002X265K

with collar

U0001X265R

for acrylic prostheses

U0001X265K

with collar

A0001X555

Orbita

A0002X265

Auricular Nasal

T-Line (Telescopic abutment)

reg Magnetic Retention Steco Titanmagnetics for IE

OslashNOTE See page 20-23 for more information on Steco Titanmagnetics prosthetics and instrumentation

08

Medium Bone

Oslash375mm Parallel Walled (IE3) 3mm length

4mm length

6mm length

Oslash20mm

Oslash30mm

D-RB-M

S

Medium Bone

Oslash375mm Parallel Walled (IE4)

Oslash20mm

Oslash30mm

D-RB-M

S

Oslash375mm Parallel Walled (IE6)

Soft Bone

Oslash20mm

D-RB-M

S

Soft Bone

Oslash20mm

D-RB-M

S

Soft Bone

Oslash20mm

D-RB-M

S

Dense Bone

Oslash20mm

Oslash30mm

D-RB-M

S

Dense Bone

Oslash20mm

Oslash30mm

D-RB-M

S

Medium Bone

Oslash20mm

Oslash30mm

D-RB-M

S

Dense Bone

Oslash20mm

Oslash30mm

D-RB-M

S

D-TAP-IB

S

D-TAP-IB

S

D-TAP-IB

S

Medium Bone

Oslash40mm Tapered (IET4 IET 4)i

Soft Bone

Oslash20mm

D-RB-M

S

Dense Bone

Oslash20mm

Oslash40mm

D-RB-M

S

Oslash20mm

Oslash40mm

D-RB-M

S

NOTE The total implant length is reached when the flange of the 4mm tapered drill touches the bone surface Drilling beyond this point may compromise primary stability of the implant

4mm length

Site Preparation SequenceSite Preparation SequenceSite Preparation Sequence

IET4

09

Most instruments are available in various lengths

IET 4i

I-WI-CST I-WI-SS

(Internal Drive)

Oslash45mm Tapered (IETi4)

INSTRUMENTATION

Wrench Converters

Wrench Converters

Insertion Tools

I-HIDU-S M L I-WIID-S LI-HID-S M L

Handpiece InsertUniversal

Wrench InsertHandpiece Insertwith WampH

I-WI-CST I-WI-SH

IE4IE3 IE6

Fixture Mounted Implants (Parallel Walled amp Tapered)

Internal Drive Implant (Tapered)

Insertion Tools

I-CON-X

Fixture Mount Driver

(With WampH)

Fixture Mount Universal Driver(Without WampH)

I-CONU-X

For Handpiece inserts (Latch-type)

featuring the WampH hex

For HEX connection of fixture mounts

For Handpiece inserts (Latch-type) featuring the WampH hex

For SQUARE connection of fixture mounts

and instruments

PLACEMENT TOOLS DRILLS DRIVERS

10

IE3

IE4

IE6

IET

I-EO-EG For surgical placement of Extraoral ImplantsI-EO-EG

INSTRUMENT TRAY

Pilot DrillD-RB-MS

Oslash20mmTwist Drills

Final Twist Drills

Final Tapered Drill

Placement Tools

D-20E-03F

D-20E-04F

D-20E-06F

D-30E-03F

D-30E-04F

D-30E-06F

D-40E-04F

I-CON-X XS

I-CONU-X XS

Handpiece Insert

Convert latch type instrument with the WampH hex to fit with square connection

Torque wrench

Converter

Drill Extensions

I-WI-C-S L

I-DE-G

I-DE-K

(Optional)

Bone Tap

D-TAP-IBS

(Optional)

I-WI-AWrench Insert

Standard Abutment Drivers(Hex)

I-AD

I-HAD

Handheld

Handpiece Insert

I-HID-S M L

Internal Drive

Handpiece Insert

I-WIID-S LInternal Drive

Wrench Insert

Hex Drivers (122mm)

I-HD-SMLHandheld

I-HHD-22SMLHandpiece Insert

I-WI-22SMLWrench Insert

Cover Screw Drivers(09mm)

I-CS-HD L

I-HHD-09

I-WI-09

09mm Hex

Handheld

Handpiece Insert

Wrench Insert

11

Flat Spanner

I-SP-X (System specific)

I-TWS-B45 I-TWS-B100

I-TWS

Wrench Torque Attachments

Wrench Converters

I-WI-CST

For Handpiece inserts (Latch-type)

featuring the WampH hex

I-WI-SL

For Handpiece inserts (Latch-type)

without the WampH hex

I-WI-SS

For SQUARE connection of fixture mounts

and instruments

I-WI-SH

For HEX connection of fixture mounts

All instruments and tooling used during the procedure must be maintained in good condition and cleaned and sterilized prior to to use Please consult the Southern Implants

Cleaning and Sterilization Procedure Guidelines (CAT-1039) for guidance concerning the maintenance of drills instruments and surgical trays

NOTE

Most Instruments available in Short Medium Long

The surgical kit has an intuitive layout to guide the surgeon through the drill sequence

For Polishing Protector Caps refer to CAT-1010

12

NOTE Refer to CAT-1203 for alternative drivers

UNIVERSAL 122127 UNIVERSAL 122127UNIVERSAL 122127

HANDHELD HANDPIECE WRENCH

I-HD-SML

122 122122

I-HHD-22SML I-WI-22SMLI-HHD-22U-SMLI-HD-22U-SML I-WI-22U-SML

DRIVER AND SCREW INFORMATION

I-UGI-SML I-HUG-SML I-WI-UG-SML

UNIGRIP Drivers

Alternative Drivers

Hex Drivers

Laboratory Screw

1 Series Screws

TORQUE 10-15Ncm

Head Diameter 225mm

122 Hex 122 HexUnigrip

TSH1GSH1

TSU1GSU1 (Blackened and for

laboratory use only)

BSH1

NOTE bull Due to design revisions screw tips may be flat or rounded

bull Always ensure that the correct screw is used for the relevant implant and component

Screw Head Connections

Hex Unigrip

STECO TITANMAGNETICS

Dual magnet system The construction principle

Sm2Co1

7 Magnet

Implant-specific geometry

Corrosion-proof titanium housing

Prostheses magnet

Insert Attachment

Magnetic attachments for facial prosthesis

The universal and easily manageable solution for implant-supported face prostheses and obturators

bull Refer to CAT-1003 for alternative slotted 1 Series screws

Two open magnet fields exert a force of attraction over a longer distance than mono-magnet systems

13

STECO TITANMAGNETICS

Oslash480 Oslash580

Height

265 mmHeight

315 mmProstheses magnet

Insert Attachment

30 N (300 g)Withdrawal force16 N (163 g)

X-Line Z-Line

reg The slightly curved surface of the spherical StecoTitanmagnetics X-Line and the Z-Line facilitates self centering and has the lowest lateral force introduction into the implant X-Line and Z-Line are therefore particularly suitable for short implants Due to the absence of lateral steering they are also indicated for highly divergent implants

Spherical magnets

T-Line

reg The StecoTitanmagnetics T-Line was developed exclusively for extraoral use The telescopic bearing of 25 mm gives the facial prosthesis secure fixation on the tissue The design allows a certain amount of rotation and axial movement without losing the withdrawal force

Telescopic magnets

Oslash580

Distance height

Distance height

Distance height

Height

57 mm

14 N (143 g)

Prosthesis magnet

Withdrawal force

Insert Attachment

Prosthetic Components

In X-Line and Z-Line there are prostheses magnets for acrylic and with additional retention for silicone For more lateral support there are prostheses magnets with extended collars available

For silicone

with collar and retention ring

with retention ring with rotation protection with collar

For acrylicFor silicone For acrylic

Universalwith retention ring

In the T-Line there are also prostheses magnets for acrylic and with additional retention for silicone

Accessories

To make a new prostheses each product line has its own compatible impression copings and laboratory analogues

Impression Copings- magnetic impression without screws- lock magnetically to the insert- the external geometry ensures the impression material is securely fi xed

Z-Line T-LineX-Line

Laboratory Analogues- for making models quickly and hygienically- the original implant does not have to be used on the insertion point of an analogue

- there is no need for time-consuming cleaning- a length of 16 mm is also available on request

Z-Line T-LineX-Line

The Healing-Flange is placed on the insert to stabilize the bandage on fresh skin perforation tissue after application of the insert This minimizes excessive tissue proliferation The Healing-Flange has its own magnet core and is made off tissue friendly Titanium

Healing Flange

X-Line T-Line

Insertion standard tools

X-Line

H0004X2

Connector to handpiece

H0004X4

H0004X1

Connector to ratchet

Z-Line amp T-Line

H0004T2

Connector to handpiece

Connector to ratchet

H0004T4

H0004T1

Connector to I-Ratchet-2Connector to I-Ratchet-2

14

APEXDIAMETER

PLATFORM DIAMETER

PLATFORM DIAMETER (flange)

MAJOR DIAMETER

COLLAR HEIGHT

THREADPITCH

APEXDIAMETER

THREADPITCH

COLLAR HEIGHT

HEXHEIGHT

HEXWIDTH

ProstheticColourCode

PLATFORM DIAMETER

(flange)

MAJOR DIAMETER

IE

IET

IETi

375

45

45

480

407

407

270

270

270

040 280

245

245

Cylindricalor Tapered

CT 63 4

radic

radic

radic

radic radic06

05

05

025

025

07

07

07

C

T

T

Oslash375mm

Oslash45mm

Oslash45mm

RANGE IMPLANT LENGTHS

IMPLANT DIMENSIONS AND INFORMATION

The following symbols are used on our packaging labels and they indicate the following

1

3

4

6

7

6

AMERICAS ASIA Southern Implants North America Inc 225 Chimney Corner Lane Suite 3011 Jupiter FL 33458 United States of America

Southern Implants UK Ltd Building 3 Chiswick Park566 Chiswick High Road London W4 5YA United KingdomEC REP

1 Albert Rd IRENE 0062 South AfricaSouthern Implants (Pty) Ltd

22797

STERILIZE2

only

yyyy-mm

LOTLOT

5

IET4

IET4

IET4

Doc 0000-0 Rev 0

IET4

REF

REF

REF

REF

(01) 00000000000000(17) Date packed(10) Expiry Date

Ext Hex Tapered Implant Ultra-Short Oslash45 x 4mm

Oslash45 x 4mm Oslash45 x 4mm

Manufacturer1

2

3

4

7

55

6

STERILE R

Implant details and size

Implant image

Sterilization using Irradiation

Caution

CE mark and notified body number

Expiry date

Prescription device

ii

STERILE R

22

STERILIZE2

STERILIZE2 Do not Resterilize

Consult instruction for use

Do not reuse

Sterile unless package is opened or damaged

CAUTION FEDERAL LAW RESTRICTS THE DEVICE TO SALE BY OR ON THE ORDER OF A LICENCED HEALTH CARE PROVIDER

Patient sticker for documentation purposes(to be used by health care provider on patient file)

2D Bar codingContains the GTIN Expiry Date and LOT Number

EXPLANATION OF SYMBOLS

15

copy2019 Southern Implants (Pty) Ltd All rights reserved Co-Axis Southern Implantsand Subcrestal Angle Correctionare registered trademarks and Body-Shift INVERTA and PROVATA are trademarks of Southern Implants (Pty) Ltd Not all implants are available in all markets

CAT-2010-08 (C1073)

For more information please contact your Southern Implants Representative or visit southernimplantscom

Subsidiaries

AustraliaSouthern Implants AustraliaT +61-2-8076-9337E infosouthernimplantscomau

United KingdomSouthern Implants UKT +44-20-8899-6845 6 7E infosouthernimplantscouk

USA and CanadaSouthern Implants North America IncT +1-561-472-0990E customercaresouthernimplantscom

South Africa ndash Headquarters 1 Albert Road Irene RSAT +27-12-667-1046 | E infosouthernimplantscom

Southern Implants Products are distributed world-wide please visit southernimplantscom for a list of Distributors

  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • Page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Page 15
  • Page 16

04

Images are for illustration purposes only and do not necessarily accurately represent the productNOTE

Not all products are cleared for sale in all countries

All dimensions in this catalogue are in mm unless otherwise specified

05

EXTERNAL HEX

Oslash375mm Oslash45mm

ULTRA-SHORT

06

Implant dimensions and information - page 14

Implant dimensions and information - page 14

IE 4 6

IE 3

Implants are available in lengths of

Implants are available in lengths of

SCU2

SC4

IE3

234568lengths

234568lengths

Oslash45 Oslash55

WBTB

3mm

IET 4

IETi 4

IE4 IE6

41mm4mm

6mm

41mm

IET4 IET 4i(Internal Drive)

Item code

Item code

Implant lengths (in mm)

Implant lengths (in mm)

Item code Implant lengths (in mm)

Cylindrical

Cylindrical

Tapered

(Internal Drive)

8length

Oslash45

TBE8n

Cover Screw Healing Abutments

Surgical Components

Cover Screw Healing Abutments

Surgical Components

Oslash375mm Oslash45mm Implants Oslash375mm Oslash45mm Implants (Parallel Walled amp Tapered)(Parallel Walled amp Tapered)Oslash375mm Oslash45mm Implants (Parallel Walled amp Tapered)

Oslash375mm Implants Oslash375mm Implants (Parallel Walled)(Parallel Walled)Oslash375mm Implants (Parallel Walled)

07

SC4

IE3

TBE8n

WB

TB

StandardAbutment

HealingAbutment

Impression Coping

Laboratory Analogue

Prosthetic Components

Retaining Screws

CB1(PICK-UP)

3 4 55 7 85 10

ABE LS1

1 Series Screws

GoldGold

GCP3GCP3

Titanium

TC9

SCU2

IET4

IET 4i

IE6

IE4

Prosthetic FlowchartProsthetic FlowchartProsthetic Flowchart

Prosthetic FlowchartProsthetic FlowchartProsthetic Flowchart

IE6

IE4

IE3 I0201Z475I0201Z600I0201Z700I0201Z800 A0002Z695 M0001Z1000

475 6 7 8 with collar

U0001Z315KU0001Z315

for acrylic prostheses

U0002Z315K

with collar

Z-Line (wide spherical abutment)

I0201T520I0201T720 E0004T1 A0002T750 M0001T1050

52 72

U0001T570

for acrylic prostheses

U0002T570

for silcone prostheses

X-Line (standard spherical abutment)

AbutmentsLaboratory Analogues Magneto

I0201X350I0201X500I0201X650I0201X800 E0004X1 M0001X900

35 5 65 8

for silcone prostheses

U0002Z315

U0002X265

for silcone prostheses

U0002X265K

with collar

U0001X265R

for acrylic prostheses

U0001X265K

with collar

A0001X555

Orbita

A0002X265

Auricular Nasal

T-Line (Telescopic abutment)

reg Magnetic Retention Steco Titanmagnetics for IE

OslashNOTE See page 20-23 for more information on Steco Titanmagnetics prosthetics and instrumentation

08

Medium Bone

Oslash375mm Parallel Walled (IE3) 3mm length

4mm length

6mm length

Oslash20mm

Oslash30mm

D-RB-M

S

Medium Bone

Oslash375mm Parallel Walled (IE4)

Oslash20mm

Oslash30mm

D-RB-M

S

Oslash375mm Parallel Walled (IE6)

Soft Bone

Oslash20mm

D-RB-M

S

Soft Bone

Oslash20mm

D-RB-M

S

Soft Bone

Oslash20mm

D-RB-M

S

Dense Bone

Oslash20mm

Oslash30mm

D-RB-M

S

Dense Bone

Oslash20mm

Oslash30mm

D-RB-M

S

Medium Bone

Oslash20mm

Oslash30mm

D-RB-M

S

Dense Bone

Oslash20mm

Oslash30mm

D-RB-M

S

D-TAP-IB

S

D-TAP-IB

S

D-TAP-IB

S

Medium Bone

Oslash40mm Tapered (IET4 IET 4)i

Soft Bone

Oslash20mm

D-RB-M

S

Dense Bone

Oslash20mm

Oslash40mm

D-RB-M

S

Oslash20mm

Oslash40mm

D-RB-M

S

NOTE The total implant length is reached when the flange of the 4mm tapered drill touches the bone surface Drilling beyond this point may compromise primary stability of the implant

4mm length

Site Preparation SequenceSite Preparation SequenceSite Preparation Sequence

IET4

09

Most instruments are available in various lengths

IET 4i

I-WI-CST I-WI-SS

(Internal Drive)

Oslash45mm Tapered (IETi4)

INSTRUMENTATION

Wrench Converters

Wrench Converters

Insertion Tools

I-HIDU-S M L I-WIID-S LI-HID-S M L

Handpiece InsertUniversal

Wrench InsertHandpiece Insertwith WampH

I-WI-CST I-WI-SH

IE4IE3 IE6

Fixture Mounted Implants (Parallel Walled amp Tapered)

Internal Drive Implant (Tapered)

Insertion Tools

I-CON-X

Fixture Mount Driver

(With WampH)

Fixture Mount Universal Driver(Without WampH)

I-CONU-X

For Handpiece inserts (Latch-type)

featuring the WampH hex

For HEX connection of fixture mounts

For Handpiece inserts (Latch-type) featuring the WampH hex

For SQUARE connection of fixture mounts

and instruments

PLACEMENT TOOLS DRILLS DRIVERS

10

IE3

IE4

IE6

IET

I-EO-EG For surgical placement of Extraoral ImplantsI-EO-EG

INSTRUMENT TRAY

Pilot DrillD-RB-MS

Oslash20mmTwist Drills

Final Twist Drills

Final Tapered Drill

Placement Tools

D-20E-03F

D-20E-04F

D-20E-06F

D-30E-03F

D-30E-04F

D-30E-06F

D-40E-04F

I-CON-X XS

I-CONU-X XS

Handpiece Insert

Convert latch type instrument with the WampH hex to fit with square connection

Torque wrench

Converter

Drill Extensions

I-WI-C-S L

I-DE-G

I-DE-K

(Optional)

Bone Tap

D-TAP-IBS

(Optional)

I-WI-AWrench Insert

Standard Abutment Drivers(Hex)

I-AD

I-HAD

Handheld

Handpiece Insert

I-HID-S M L

Internal Drive

Handpiece Insert

I-WIID-S LInternal Drive

Wrench Insert

Hex Drivers (122mm)

I-HD-SMLHandheld

I-HHD-22SMLHandpiece Insert

I-WI-22SMLWrench Insert

Cover Screw Drivers(09mm)

I-CS-HD L

I-HHD-09

I-WI-09

09mm Hex

Handheld

Handpiece Insert

Wrench Insert

11

Flat Spanner

I-SP-X (System specific)

I-TWS-B45 I-TWS-B100

I-TWS

Wrench Torque Attachments

Wrench Converters

I-WI-CST

For Handpiece inserts (Latch-type)

featuring the WampH hex

I-WI-SL

For Handpiece inserts (Latch-type)

without the WampH hex

I-WI-SS

For SQUARE connection of fixture mounts

and instruments

I-WI-SH

For HEX connection of fixture mounts

All instruments and tooling used during the procedure must be maintained in good condition and cleaned and sterilized prior to to use Please consult the Southern Implants

Cleaning and Sterilization Procedure Guidelines (CAT-1039) for guidance concerning the maintenance of drills instruments and surgical trays

NOTE

Most Instruments available in Short Medium Long

The surgical kit has an intuitive layout to guide the surgeon through the drill sequence

For Polishing Protector Caps refer to CAT-1010

12

NOTE Refer to CAT-1203 for alternative drivers

UNIVERSAL 122127 UNIVERSAL 122127UNIVERSAL 122127

HANDHELD HANDPIECE WRENCH

I-HD-SML

122 122122

I-HHD-22SML I-WI-22SMLI-HHD-22U-SMLI-HD-22U-SML I-WI-22U-SML

DRIVER AND SCREW INFORMATION

I-UGI-SML I-HUG-SML I-WI-UG-SML

UNIGRIP Drivers

Alternative Drivers

Hex Drivers

Laboratory Screw

1 Series Screws

TORQUE 10-15Ncm

Head Diameter 225mm

122 Hex 122 HexUnigrip

TSH1GSH1

TSU1GSU1 (Blackened and for

laboratory use only)

BSH1

NOTE bull Due to design revisions screw tips may be flat or rounded

bull Always ensure that the correct screw is used for the relevant implant and component

Screw Head Connections

Hex Unigrip

STECO TITANMAGNETICS

Dual magnet system The construction principle

Sm2Co1

7 Magnet

Implant-specific geometry

Corrosion-proof titanium housing

Prostheses magnet

Insert Attachment

Magnetic attachments for facial prosthesis

The universal and easily manageable solution for implant-supported face prostheses and obturators

bull Refer to CAT-1003 for alternative slotted 1 Series screws

Two open magnet fields exert a force of attraction over a longer distance than mono-magnet systems

13

STECO TITANMAGNETICS

Oslash480 Oslash580

Height

265 mmHeight

315 mmProstheses magnet

Insert Attachment

30 N (300 g)Withdrawal force16 N (163 g)

X-Line Z-Line

reg The slightly curved surface of the spherical StecoTitanmagnetics X-Line and the Z-Line facilitates self centering and has the lowest lateral force introduction into the implant X-Line and Z-Line are therefore particularly suitable for short implants Due to the absence of lateral steering they are also indicated for highly divergent implants

Spherical magnets

T-Line

reg The StecoTitanmagnetics T-Line was developed exclusively for extraoral use The telescopic bearing of 25 mm gives the facial prosthesis secure fixation on the tissue The design allows a certain amount of rotation and axial movement without losing the withdrawal force

Telescopic magnets

Oslash580

Distance height

Distance height

Distance height

Height

57 mm

14 N (143 g)

Prosthesis magnet

Withdrawal force

Insert Attachment

Prosthetic Components

In X-Line and Z-Line there are prostheses magnets for acrylic and with additional retention for silicone For more lateral support there are prostheses magnets with extended collars available

For silicone

with collar and retention ring

with retention ring with rotation protection with collar

For acrylicFor silicone For acrylic

Universalwith retention ring

In the T-Line there are also prostheses magnets for acrylic and with additional retention for silicone

Accessories

To make a new prostheses each product line has its own compatible impression copings and laboratory analogues

Impression Copings- magnetic impression without screws- lock magnetically to the insert- the external geometry ensures the impression material is securely fi xed

Z-Line T-LineX-Line

Laboratory Analogues- for making models quickly and hygienically- the original implant does not have to be used on the insertion point of an analogue

- there is no need for time-consuming cleaning- a length of 16 mm is also available on request

Z-Line T-LineX-Line

The Healing-Flange is placed on the insert to stabilize the bandage on fresh skin perforation tissue after application of the insert This minimizes excessive tissue proliferation The Healing-Flange has its own magnet core and is made off tissue friendly Titanium

Healing Flange

X-Line T-Line

Insertion standard tools

X-Line

H0004X2

Connector to handpiece

H0004X4

H0004X1

Connector to ratchet

Z-Line amp T-Line

H0004T2

Connector to handpiece

Connector to ratchet

H0004T4

H0004T1

Connector to I-Ratchet-2Connector to I-Ratchet-2

14

APEXDIAMETER

PLATFORM DIAMETER

PLATFORM DIAMETER (flange)

MAJOR DIAMETER

COLLAR HEIGHT

THREADPITCH

APEXDIAMETER

THREADPITCH

COLLAR HEIGHT

HEXHEIGHT

HEXWIDTH

ProstheticColourCode

PLATFORM DIAMETER

(flange)

MAJOR DIAMETER

IE

IET

IETi

375

45

45

480

407

407

270

270

270

040 280

245

245

Cylindricalor Tapered

CT 63 4

radic

radic

radic

radic radic06

05

05

025

025

07

07

07

C

T

T

Oslash375mm

Oslash45mm

Oslash45mm

RANGE IMPLANT LENGTHS

IMPLANT DIMENSIONS AND INFORMATION

The following symbols are used on our packaging labels and they indicate the following

1

3

4

6

7

6

AMERICAS ASIA Southern Implants North America Inc 225 Chimney Corner Lane Suite 3011 Jupiter FL 33458 United States of America

Southern Implants UK Ltd Building 3 Chiswick Park566 Chiswick High Road London W4 5YA United KingdomEC REP

1 Albert Rd IRENE 0062 South AfricaSouthern Implants (Pty) Ltd

22797

STERILIZE2

only

yyyy-mm

LOTLOT

5

IET4

IET4

IET4

Doc 0000-0 Rev 0

IET4

REF

REF

REF

REF

(01) 00000000000000(17) Date packed(10) Expiry Date

Ext Hex Tapered Implant Ultra-Short Oslash45 x 4mm

Oslash45 x 4mm Oslash45 x 4mm

Manufacturer1

2

3

4

7

55

6

STERILE R

Implant details and size

Implant image

Sterilization using Irradiation

Caution

CE mark and notified body number

Expiry date

Prescription device

ii

STERILE R

22

STERILIZE2

STERILIZE2 Do not Resterilize

Consult instruction for use

Do not reuse

Sterile unless package is opened or damaged

CAUTION FEDERAL LAW RESTRICTS THE DEVICE TO SALE BY OR ON THE ORDER OF A LICENCED HEALTH CARE PROVIDER

Patient sticker for documentation purposes(to be used by health care provider on patient file)

2D Bar codingContains the GTIN Expiry Date and LOT Number

EXPLANATION OF SYMBOLS

15

copy2019 Southern Implants (Pty) Ltd All rights reserved Co-Axis Southern Implantsand Subcrestal Angle Correctionare registered trademarks and Body-Shift INVERTA and PROVATA are trademarks of Southern Implants (Pty) Ltd Not all implants are available in all markets

CAT-2010-08 (C1073)

For more information please contact your Southern Implants Representative or visit southernimplantscom

Subsidiaries

AustraliaSouthern Implants AustraliaT +61-2-8076-9337E infosouthernimplantscomau

United KingdomSouthern Implants UKT +44-20-8899-6845 6 7E infosouthernimplantscouk

USA and CanadaSouthern Implants North America IncT +1-561-472-0990E customercaresouthernimplantscom

South Africa ndash Headquarters 1 Albert Road Irene RSAT +27-12-667-1046 | E infosouthernimplantscom

Southern Implants Products are distributed world-wide please visit southernimplantscom for a list of Distributors

  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • Page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Page 15
  • Page 16

05

EXTERNAL HEX

Oslash375mm Oslash45mm

ULTRA-SHORT

06

Implant dimensions and information - page 14

Implant dimensions and information - page 14

IE 4 6

IE 3

Implants are available in lengths of

Implants are available in lengths of

SCU2

SC4

IE3

234568lengths

234568lengths

Oslash45 Oslash55

WBTB

3mm

IET 4

IETi 4

IE4 IE6

41mm4mm

6mm

41mm

IET4 IET 4i(Internal Drive)

Item code

Item code

Implant lengths (in mm)

Implant lengths (in mm)

Item code Implant lengths (in mm)

Cylindrical

Cylindrical

Tapered

(Internal Drive)

8length

Oslash45

TBE8n

Cover Screw Healing Abutments

Surgical Components

Cover Screw Healing Abutments

Surgical Components

Oslash375mm Oslash45mm Implants Oslash375mm Oslash45mm Implants (Parallel Walled amp Tapered)(Parallel Walled amp Tapered)Oslash375mm Oslash45mm Implants (Parallel Walled amp Tapered)

Oslash375mm Implants Oslash375mm Implants (Parallel Walled)(Parallel Walled)Oslash375mm Implants (Parallel Walled)

07

SC4

IE3

TBE8n

WB

TB

StandardAbutment

HealingAbutment

Impression Coping

Laboratory Analogue

Prosthetic Components

Retaining Screws

CB1(PICK-UP)

3 4 55 7 85 10

ABE LS1

1 Series Screws

GoldGold

GCP3GCP3

Titanium

TC9

SCU2

IET4

IET 4i

IE6

IE4

Prosthetic FlowchartProsthetic FlowchartProsthetic Flowchart

Prosthetic FlowchartProsthetic FlowchartProsthetic Flowchart

IE6

IE4

IE3 I0201Z475I0201Z600I0201Z700I0201Z800 A0002Z695 M0001Z1000

475 6 7 8 with collar

U0001Z315KU0001Z315

for acrylic prostheses

U0002Z315K

with collar

Z-Line (wide spherical abutment)

I0201T520I0201T720 E0004T1 A0002T750 M0001T1050

52 72

U0001T570

for acrylic prostheses

U0002T570

for silcone prostheses

X-Line (standard spherical abutment)

AbutmentsLaboratory Analogues Magneto

I0201X350I0201X500I0201X650I0201X800 E0004X1 M0001X900

35 5 65 8

for silcone prostheses

U0002Z315

U0002X265

for silcone prostheses

U0002X265K

with collar

U0001X265R

for acrylic prostheses

U0001X265K

with collar

A0001X555

Orbita

A0002X265

Auricular Nasal

T-Line (Telescopic abutment)

reg Magnetic Retention Steco Titanmagnetics for IE

OslashNOTE See page 20-23 for more information on Steco Titanmagnetics prosthetics and instrumentation

08

Medium Bone

Oslash375mm Parallel Walled (IE3) 3mm length

4mm length

6mm length

Oslash20mm

Oslash30mm

D-RB-M

S

Medium Bone

Oslash375mm Parallel Walled (IE4)

Oslash20mm

Oslash30mm

D-RB-M

S

Oslash375mm Parallel Walled (IE6)

Soft Bone

Oslash20mm

D-RB-M

S

Soft Bone

Oslash20mm

D-RB-M

S

Soft Bone

Oslash20mm

D-RB-M

S

Dense Bone

Oslash20mm

Oslash30mm

D-RB-M

S

Dense Bone

Oslash20mm

Oslash30mm

D-RB-M

S

Medium Bone

Oslash20mm

Oslash30mm

D-RB-M

S

Dense Bone

Oslash20mm

Oslash30mm

D-RB-M

S

D-TAP-IB

S

D-TAP-IB

S

D-TAP-IB

S

Medium Bone

Oslash40mm Tapered (IET4 IET 4)i

Soft Bone

Oslash20mm

D-RB-M

S

Dense Bone

Oslash20mm

Oslash40mm

D-RB-M

S

Oslash20mm

Oslash40mm

D-RB-M

S

NOTE The total implant length is reached when the flange of the 4mm tapered drill touches the bone surface Drilling beyond this point may compromise primary stability of the implant

4mm length

Site Preparation SequenceSite Preparation SequenceSite Preparation Sequence

IET4

09

Most instruments are available in various lengths

IET 4i

I-WI-CST I-WI-SS

(Internal Drive)

Oslash45mm Tapered (IETi4)

INSTRUMENTATION

Wrench Converters

Wrench Converters

Insertion Tools

I-HIDU-S M L I-WIID-S LI-HID-S M L

Handpiece InsertUniversal

Wrench InsertHandpiece Insertwith WampH

I-WI-CST I-WI-SH

IE4IE3 IE6

Fixture Mounted Implants (Parallel Walled amp Tapered)

Internal Drive Implant (Tapered)

Insertion Tools

I-CON-X

Fixture Mount Driver

(With WampH)

Fixture Mount Universal Driver(Without WampH)

I-CONU-X

For Handpiece inserts (Latch-type)

featuring the WampH hex

For HEX connection of fixture mounts

For Handpiece inserts (Latch-type) featuring the WampH hex

For SQUARE connection of fixture mounts

and instruments

PLACEMENT TOOLS DRILLS DRIVERS

10

IE3

IE4

IE6

IET

I-EO-EG For surgical placement of Extraoral ImplantsI-EO-EG

INSTRUMENT TRAY

Pilot DrillD-RB-MS

Oslash20mmTwist Drills

Final Twist Drills

Final Tapered Drill

Placement Tools

D-20E-03F

D-20E-04F

D-20E-06F

D-30E-03F

D-30E-04F

D-30E-06F

D-40E-04F

I-CON-X XS

I-CONU-X XS

Handpiece Insert

Convert latch type instrument with the WampH hex to fit with square connection

Torque wrench

Converter

Drill Extensions

I-WI-C-S L

I-DE-G

I-DE-K

(Optional)

Bone Tap

D-TAP-IBS

(Optional)

I-WI-AWrench Insert

Standard Abutment Drivers(Hex)

I-AD

I-HAD

Handheld

Handpiece Insert

I-HID-S M L

Internal Drive

Handpiece Insert

I-WIID-S LInternal Drive

Wrench Insert

Hex Drivers (122mm)

I-HD-SMLHandheld

I-HHD-22SMLHandpiece Insert

I-WI-22SMLWrench Insert

Cover Screw Drivers(09mm)

I-CS-HD L

I-HHD-09

I-WI-09

09mm Hex

Handheld

Handpiece Insert

Wrench Insert

11

Flat Spanner

I-SP-X (System specific)

I-TWS-B45 I-TWS-B100

I-TWS

Wrench Torque Attachments

Wrench Converters

I-WI-CST

For Handpiece inserts (Latch-type)

featuring the WampH hex

I-WI-SL

For Handpiece inserts (Latch-type)

without the WampH hex

I-WI-SS

For SQUARE connection of fixture mounts

and instruments

I-WI-SH

For HEX connection of fixture mounts

All instruments and tooling used during the procedure must be maintained in good condition and cleaned and sterilized prior to to use Please consult the Southern Implants

Cleaning and Sterilization Procedure Guidelines (CAT-1039) for guidance concerning the maintenance of drills instruments and surgical trays

NOTE

Most Instruments available in Short Medium Long

The surgical kit has an intuitive layout to guide the surgeon through the drill sequence

For Polishing Protector Caps refer to CAT-1010

12

NOTE Refer to CAT-1203 for alternative drivers

UNIVERSAL 122127 UNIVERSAL 122127UNIVERSAL 122127

HANDHELD HANDPIECE WRENCH

I-HD-SML

122 122122

I-HHD-22SML I-WI-22SMLI-HHD-22U-SMLI-HD-22U-SML I-WI-22U-SML

DRIVER AND SCREW INFORMATION

I-UGI-SML I-HUG-SML I-WI-UG-SML

UNIGRIP Drivers

Alternative Drivers

Hex Drivers

Laboratory Screw

1 Series Screws

TORQUE 10-15Ncm

Head Diameter 225mm

122 Hex 122 HexUnigrip

TSH1GSH1

TSU1GSU1 (Blackened and for

laboratory use only)

BSH1

NOTE bull Due to design revisions screw tips may be flat or rounded

bull Always ensure that the correct screw is used for the relevant implant and component

Screw Head Connections

Hex Unigrip

STECO TITANMAGNETICS

Dual magnet system The construction principle

Sm2Co1

7 Magnet

Implant-specific geometry

Corrosion-proof titanium housing

Prostheses magnet

Insert Attachment

Magnetic attachments for facial prosthesis

The universal and easily manageable solution for implant-supported face prostheses and obturators

bull Refer to CAT-1003 for alternative slotted 1 Series screws

Two open magnet fields exert a force of attraction over a longer distance than mono-magnet systems

13

STECO TITANMAGNETICS

Oslash480 Oslash580

Height

265 mmHeight

315 mmProstheses magnet

Insert Attachment

30 N (300 g)Withdrawal force16 N (163 g)

X-Line Z-Line

reg The slightly curved surface of the spherical StecoTitanmagnetics X-Line and the Z-Line facilitates self centering and has the lowest lateral force introduction into the implant X-Line and Z-Line are therefore particularly suitable for short implants Due to the absence of lateral steering they are also indicated for highly divergent implants

Spherical magnets

T-Line

reg The StecoTitanmagnetics T-Line was developed exclusively for extraoral use The telescopic bearing of 25 mm gives the facial prosthesis secure fixation on the tissue The design allows a certain amount of rotation and axial movement without losing the withdrawal force

Telescopic magnets

Oslash580

Distance height

Distance height

Distance height

Height

57 mm

14 N (143 g)

Prosthesis magnet

Withdrawal force

Insert Attachment

Prosthetic Components

In X-Line and Z-Line there are prostheses magnets for acrylic and with additional retention for silicone For more lateral support there are prostheses magnets with extended collars available

For silicone

with collar and retention ring

with retention ring with rotation protection with collar

For acrylicFor silicone For acrylic

Universalwith retention ring

In the T-Line there are also prostheses magnets for acrylic and with additional retention for silicone

Accessories

To make a new prostheses each product line has its own compatible impression copings and laboratory analogues

Impression Copings- magnetic impression without screws- lock magnetically to the insert- the external geometry ensures the impression material is securely fi xed

Z-Line T-LineX-Line

Laboratory Analogues- for making models quickly and hygienically- the original implant does not have to be used on the insertion point of an analogue

- there is no need for time-consuming cleaning- a length of 16 mm is also available on request

Z-Line T-LineX-Line

The Healing-Flange is placed on the insert to stabilize the bandage on fresh skin perforation tissue after application of the insert This minimizes excessive tissue proliferation The Healing-Flange has its own magnet core and is made off tissue friendly Titanium

Healing Flange

X-Line T-Line

Insertion standard tools

X-Line

H0004X2

Connector to handpiece

H0004X4

H0004X1

Connector to ratchet

Z-Line amp T-Line

H0004T2

Connector to handpiece

Connector to ratchet

H0004T4

H0004T1

Connector to I-Ratchet-2Connector to I-Ratchet-2

14

APEXDIAMETER

PLATFORM DIAMETER

PLATFORM DIAMETER (flange)

MAJOR DIAMETER

COLLAR HEIGHT

THREADPITCH

APEXDIAMETER

THREADPITCH

COLLAR HEIGHT

HEXHEIGHT

HEXWIDTH

ProstheticColourCode

PLATFORM DIAMETER

(flange)

MAJOR DIAMETER

IE

IET

IETi

375

45

45

480

407

407

270

270

270

040 280

245

245

Cylindricalor Tapered

CT 63 4

radic

radic

radic

radic radic06

05

05

025

025

07

07

07

C

T

T

Oslash375mm

Oslash45mm

Oslash45mm

RANGE IMPLANT LENGTHS

IMPLANT DIMENSIONS AND INFORMATION

The following symbols are used on our packaging labels and they indicate the following

1

3

4

6

7

6

AMERICAS ASIA Southern Implants North America Inc 225 Chimney Corner Lane Suite 3011 Jupiter FL 33458 United States of America

Southern Implants UK Ltd Building 3 Chiswick Park566 Chiswick High Road London W4 5YA United KingdomEC REP

1 Albert Rd IRENE 0062 South AfricaSouthern Implants (Pty) Ltd

22797

STERILIZE2

only

yyyy-mm

LOTLOT

5

IET4

IET4

IET4

Doc 0000-0 Rev 0

IET4

REF

REF

REF

REF

(01) 00000000000000(17) Date packed(10) Expiry Date

Ext Hex Tapered Implant Ultra-Short Oslash45 x 4mm

Oslash45 x 4mm Oslash45 x 4mm

Manufacturer1

2

3

4

7

55

6

STERILE R

Implant details and size

Implant image

Sterilization using Irradiation

Caution

CE mark and notified body number

Expiry date

Prescription device

ii

STERILE R

22

STERILIZE2

STERILIZE2 Do not Resterilize

Consult instruction for use

Do not reuse

Sterile unless package is opened or damaged

CAUTION FEDERAL LAW RESTRICTS THE DEVICE TO SALE BY OR ON THE ORDER OF A LICENCED HEALTH CARE PROVIDER

Patient sticker for documentation purposes(to be used by health care provider on patient file)

2D Bar codingContains the GTIN Expiry Date and LOT Number

EXPLANATION OF SYMBOLS

15

copy2019 Southern Implants (Pty) Ltd All rights reserved Co-Axis Southern Implantsand Subcrestal Angle Correctionare registered trademarks and Body-Shift INVERTA and PROVATA are trademarks of Southern Implants (Pty) Ltd Not all implants are available in all markets

CAT-2010-08 (C1073)

For more information please contact your Southern Implants Representative or visit southernimplantscom

Subsidiaries

AustraliaSouthern Implants AustraliaT +61-2-8076-9337E infosouthernimplantscomau

United KingdomSouthern Implants UKT +44-20-8899-6845 6 7E infosouthernimplantscouk

USA and CanadaSouthern Implants North America IncT +1-561-472-0990E customercaresouthernimplantscom

South Africa ndash Headquarters 1 Albert Road Irene RSAT +27-12-667-1046 | E infosouthernimplantscom

Southern Implants Products are distributed world-wide please visit southernimplantscom for a list of Distributors

  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • Page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Page 15
  • Page 16

06

Implant dimensions and information - page 14

Implant dimensions and information - page 14

IE 4 6

IE 3

Implants are available in lengths of

Implants are available in lengths of

SCU2

SC4

IE3

234568lengths

234568lengths

Oslash45 Oslash55

WBTB

3mm

IET 4

IETi 4

IE4 IE6

41mm4mm

6mm

41mm

IET4 IET 4i(Internal Drive)

Item code

Item code

Implant lengths (in mm)

Implant lengths (in mm)

Item code Implant lengths (in mm)

Cylindrical

Cylindrical

Tapered

(Internal Drive)

8length

Oslash45

TBE8n

Cover Screw Healing Abutments

Surgical Components

Cover Screw Healing Abutments

Surgical Components

Oslash375mm Oslash45mm Implants Oslash375mm Oslash45mm Implants (Parallel Walled amp Tapered)(Parallel Walled amp Tapered)Oslash375mm Oslash45mm Implants (Parallel Walled amp Tapered)

Oslash375mm Implants Oslash375mm Implants (Parallel Walled)(Parallel Walled)Oslash375mm Implants (Parallel Walled)

07

SC4

IE3

TBE8n

WB

TB

StandardAbutment

HealingAbutment

Impression Coping

Laboratory Analogue

Prosthetic Components

Retaining Screws

CB1(PICK-UP)

3 4 55 7 85 10

ABE LS1

1 Series Screws

GoldGold

GCP3GCP3

Titanium

TC9

SCU2

IET4

IET 4i

IE6

IE4

Prosthetic FlowchartProsthetic FlowchartProsthetic Flowchart

Prosthetic FlowchartProsthetic FlowchartProsthetic Flowchart

IE6

IE4

IE3 I0201Z475I0201Z600I0201Z700I0201Z800 A0002Z695 M0001Z1000

475 6 7 8 with collar

U0001Z315KU0001Z315

for acrylic prostheses

U0002Z315K

with collar

Z-Line (wide spherical abutment)

I0201T520I0201T720 E0004T1 A0002T750 M0001T1050

52 72

U0001T570

for acrylic prostheses

U0002T570

for silcone prostheses

X-Line (standard spherical abutment)

AbutmentsLaboratory Analogues Magneto

I0201X350I0201X500I0201X650I0201X800 E0004X1 M0001X900

35 5 65 8

for silcone prostheses

U0002Z315

U0002X265

for silcone prostheses

U0002X265K

with collar

U0001X265R

for acrylic prostheses

U0001X265K

with collar

A0001X555

Orbita

A0002X265

Auricular Nasal

T-Line (Telescopic abutment)

reg Magnetic Retention Steco Titanmagnetics for IE

OslashNOTE See page 20-23 for more information on Steco Titanmagnetics prosthetics and instrumentation

08

Medium Bone

Oslash375mm Parallel Walled (IE3) 3mm length

4mm length

6mm length

Oslash20mm

Oslash30mm

D-RB-M

S

Medium Bone

Oslash375mm Parallel Walled (IE4)

Oslash20mm

Oslash30mm

D-RB-M

S

Oslash375mm Parallel Walled (IE6)

Soft Bone

Oslash20mm

D-RB-M

S

Soft Bone

Oslash20mm

D-RB-M

S

Soft Bone

Oslash20mm

D-RB-M

S

Dense Bone

Oslash20mm

Oslash30mm

D-RB-M

S

Dense Bone

Oslash20mm

Oslash30mm

D-RB-M

S

Medium Bone

Oslash20mm

Oslash30mm

D-RB-M

S

Dense Bone

Oslash20mm

Oslash30mm

D-RB-M

S

D-TAP-IB

S

D-TAP-IB

S

D-TAP-IB

S

Medium Bone

Oslash40mm Tapered (IET4 IET 4)i

Soft Bone

Oslash20mm

D-RB-M

S

Dense Bone

Oslash20mm

Oslash40mm

D-RB-M

S

Oslash20mm

Oslash40mm

D-RB-M

S

NOTE The total implant length is reached when the flange of the 4mm tapered drill touches the bone surface Drilling beyond this point may compromise primary stability of the implant

4mm length

Site Preparation SequenceSite Preparation SequenceSite Preparation Sequence

IET4

09

Most instruments are available in various lengths

IET 4i

I-WI-CST I-WI-SS

(Internal Drive)

Oslash45mm Tapered (IETi4)

INSTRUMENTATION

Wrench Converters

Wrench Converters

Insertion Tools

I-HIDU-S M L I-WIID-S LI-HID-S M L

Handpiece InsertUniversal

Wrench InsertHandpiece Insertwith WampH

I-WI-CST I-WI-SH

IE4IE3 IE6

Fixture Mounted Implants (Parallel Walled amp Tapered)

Internal Drive Implant (Tapered)

Insertion Tools

I-CON-X

Fixture Mount Driver

(With WampH)

Fixture Mount Universal Driver(Without WampH)

I-CONU-X

For Handpiece inserts (Latch-type)

featuring the WampH hex

For HEX connection of fixture mounts

For Handpiece inserts (Latch-type) featuring the WampH hex

For SQUARE connection of fixture mounts

and instruments

PLACEMENT TOOLS DRILLS DRIVERS

10

IE3

IE4

IE6

IET

I-EO-EG For surgical placement of Extraoral ImplantsI-EO-EG

INSTRUMENT TRAY

Pilot DrillD-RB-MS

Oslash20mmTwist Drills

Final Twist Drills

Final Tapered Drill

Placement Tools

D-20E-03F

D-20E-04F

D-20E-06F

D-30E-03F

D-30E-04F

D-30E-06F

D-40E-04F

I-CON-X XS

I-CONU-X XS

Handpiece Insert

Convert latch type instrument with the WampH hex to fit with square connection

Torque wrench

Converter

Drill Extensions

I-WI-C-S L

I-DE-G

I-DE-K

(Optional)

Bone Tap

D-TAP-IBS

(Optional)

I-WI-AWrench Insert

Standard Abutment Drivers(Hex)

I-AD

I-HAD

Handheld

Handpiece Insert

I-HID-S M L

Internal Drive

Handpiece Insert

I-WIID-S LInternal Drive

Wrench Insert

Hex Drivers (122mm)

I-HD-SMLHandheld

I-HHD-22SMLHandpiece Insert

I-WI-22SMLWrench Insert

Cover Screw Drivers(09mm)

I-CS-HD L

I-HHD-09

I-WI-09

09mm Hex

Handheld

Handpiece Insert

Wrench Insert

11

Flat Spanner

I-SP-X (System specific)

I-TWS-B45 I-TWS-B100

I-TWS

Wrench Torque Attachments

Wrench Converters

I-WI-CST

For Handpiece inserts (Latch-type)

featuring the WampH hex

I-WI-SL

For Handpiece inserts (Latch-type)

without the WampH hex

I-WI-SS

For SQUARE connection of fixture mounts

and instruments

I-WI-SH

For HEX connection of fixture mounts

All instruments and tooling used during the procedure must be maintained in good condition and cleaned and sterilized prior to to use Please consult the Southern Implants

Cleaning and Sterilization Procedure Guidelines (CAT-1039) for guidance concerning the maintenance of drills instruments and surgical trays

NOTE

Most Instruments available in Short Medium Long

The surgical kit has an intuitive layout to guide the surgeon through the drill sequence

For Polishing Protector Caps refer to CAT-1010

12

NOTE Refer to CAT-1203 for alternative drivers

UNIVERSAL 122127 UNIVERSAL 122127UNIVERSAL 122127

HANDHELD HANDPIECE WRENCH

I-HD-SML

122 122122

I-HHD-22SML I-WI-22SMLI-HHD-22U-SMLI-HD-22U-SML I-WI-22U-SML

DRIVER AND SCREW INFORMATION

I-UGI-SML I-HUG-SML I-WI-UG-SML

UNIGRIP Drivers

Alternative Drivers

Hex Drivers

Laboratory Screw

1 Series Screws

TORQUE 10-15Ncm

Head Diameter 225mm

122 Hex 122 HexUnigrip

TSH1GSH1

TSU1GSU1 (Blackened and for

laboratory use only)

BSH1

NOTE bull Due to design revisions screw tips may be flat or rounded

bull Always ensure that the correct screw is used for the relevant implant and component

Screw Head Connections

Hex Unigrip

STECO TITANMAGNETICS

Dual magnet system The construction principle

Sm2Co1

7 Magnet

Implant-specific geometry

Corrosion-proof titanium housing

Prostheses magnet

Insert Attachment

Magnetic attachments for facial prosthesis

The universal and easily manageable solution for implant-supported face prostheses and obturators

bull Refer to CAT-1003 for alternative slotted 1 Series screws

Two open magnet fields exert a force of attraction over a longer distance than mono-magnet systems

13

STECO TITANMAGNETICS

Oslash480 Oslash580

Height

265 mmHeight

315 mmProstheses magnet

Insert Attachment

30 N (300 g)Withdrawal force16 N (163 g)

X-Line Z-Line

reg The slightly curved surface of the spherical StecoTitanmagnetics X-Line and the Z-Line facilitates self centering and has the lowest lateral force introduction into the implant X-Line and Z-Line are therefore particularly suitable for short implants Due to the absence of lateral steering they are also indicated for highly divergent implants

Spherical magnets

T-Line

reg The StecoTitanmagnetics T-Line was developed exclusively for extraoral use The telescopic bearing of 25 mm gives the facial prosthesis secure fixation on the tissue The design allows a certain amount of rotation and axial movement without losing the withdrawal force

Telescopic magnets

Oslash580

Distance height

Distance height

Distance height

Height

57 mm

14 N (143 g)

Prosthesis magnet

Withdrawal force

Insert Attachment

Prosthetic Components

In X-Line and Z-Line there are prostheses magnets for acrylic and with additional retention for silicone For more lateral support there are prostheses magnets with extended collars available

For silicone

with collar and retention ring

with retention ring with rotation protection with collar

For acrylicFor silicone For acrylic

Universalwith retention ring

In the T-Line there are also prostheses magnets for acrylic and with additional retention for silicone

Accessories

To make a new prostheses each product line has its own compatible impression copings and laboratory analogues

Impression Copings- magnetic impression without screws- lock magnetically to the insert- the external geometry ensures the impression material is securely fi xed

Z-Line T-LineX-Line

Laboratory Analogues- for making models quickly and hygienically- the original implant does not have to be used on the insertion point of an analogue

- there is no need for time-consuming cleaning- a length of 16 mm is also available on request

Z-Line T-LineX-Line

The Healing-Flange is placed on the insert to stabilize the bandage on fresh skin perforation tissue after application of the insert This minimizes excessive tissue proliferation The Healing-Flange has its own magnet core and is made off tissue friendly Titanium

Healing Flange

X-Line T-Line

Insertion standard tools

X-Line

H0004X2

Connector to handpiece

H0004X4

H0004X1

Connector to ratchet

Z-Line amp T-Line

H0004T2

Connector to handpiece

Connector to ratchet

H0004T4

H0004T1

Connector to I-Ratchet-2Connector to I-Ratchet-2

14

APEXDIAMETER

PLATFORM DIAMETER

PLATFORM DIAMETER (flange)

MAJOR DIAMETER

COLLAR HEIGHT

THREADPITCH

APEXDIAMETER

THREADPITCH

COLLAR HEIGHT

HEXHEIGHT

HEXWIDTH

ProstheticColourCode

PLATFORM DIAMETER

(flange)

MAJOR DIAMETER

IE

IET

IETi

375

45

45

480

407

407

270

270

270

040 280

245

245

Cylindricalor Tapered

CT 63 4

radic

radic

radic

radic radic06

05

05

025

025

07

07

07

C

T

T

Oslash375mm

Oslash45mm

Oslash45mm

RANGE IMPLANT LENGTHS

IMPLANT DIMENSIONS AND INFORMATION

The following symbols are used on our packaging labels and they indicate the following

1

3

4

6

7

6

AMERICAS ASIA Southern Implants North America Inc 225 Chimney Corner Lane Suite 3011 Jupiter FL 33458 United States of America

Southern Implants UK Ltd Building 3 Chiswick Park566 Chiswick High Road London W4 5YA United KingdomEC REP

1 Albert Rd IRENE 0062 South AfricaSouthern Implants (Pty) Ltd

22797

STERILIZE2

only

yyyy-mm

LOTLOT

5

IET4

IET4

IET4

Doc 0000-0 Rev 0

IET4

REF

REF

REF

REF

(01) 00000000000000(17) Date packed(10) Expiry Date

Ext Hex Tapered Implant Ultra-Short Oslash45 x 4mm

Oslash45 x 4mm Oslash45 x 4mm

Manufacturer1

2

3

4

7

55

6

STERILE R

Implant details and size

Implant image

Sterilization using Irradiation

Caution

CE mark and notified body number

Expiry date

Prescription device

ii

STERILE R

22

STERILIZE2

STERILIZE2 Do not Resterilize

Consult instruction for use

Do not reuse

Sterile unless package is opened or damaged

CAUTION FEDERAL LAW RESTRICTS THE DEVICE TO SALE BY OR ON THE ORDER OF A LICENCED HEALTH CARE PROVIDER

Patient sticker for documentation purposes(to be used by health care provider on patient file)

2D Bar codingContains the GTIN Expiry Date and LOT Number

EXPLANATION OF SYMBOLS

15

copy2019 Southern Implants (Pty) Ltd All rights reserved Co-Axis Southern Implantsand Subcrestal Angle Correctionare registered trademarks and Body-Shift INVERTA and PROVATA are trademarks of Southern Implants (Pty) Ltd Not all implants are available in all markets

CAT-2010-08 (C1073)

For more information please contact your Southern Implants Representative or visit southernimplantscom

Subsidiaries

AustraliaSouthern Implants AustraliaT +61-2-8076-9337E infosouthernimplantscomau

United KingdomSouthern Implants UKT +44-20-8899-6845 6 7E infosouthernimplantscouk

USA and CanadaSouthern Implants North America IncT +1-561-472-0990E customercaresouthernimplantscom

South Africa ndash Headquarters 1 Albert Road Irene RSAT +27-12-667-1046 | E infosouthernimplantscom

Southern Implants Products are distributed world-wide please visit southernimplantscom for a list of Distributors

  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • Page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Page 15
  • Page 16

07

SC4

IE3

TBE8n

WB

TB

StandardAbutment

HealingAbutment

Impression Coping

Laboratory Analogue

Prosthetic Components

Retaining Screws

CB1(PICK-UP)

3 4 55 7 85 10

ABE LS1

1 Series Screws

GoldGold

GCP3GCP3

Titanium

TC9

SCU2

IET4

IET 4i

IE6

IE4

Prosthetic FlowchartProsthetic FlowchartProsthetic Flowchart

Prosthetic FlowchartProsthetic FlowchartProsthetic Flowchart

IE6

IE4

IE3 I0201Z475I0201Z600I0201Z700I0201Z800 A0002Z695 M0001Z1000

475 6 7 8 with collar

U0001Z315KU0001Z315

for acrylic prostheses

U0002Z315K

with collar

Z-Line (wide spherical abutment)

I0201T520I0201T720 E0004T1 A0002T750 M0001T1050

52 72

U0001T570

for acrylic prostheses

U0002T570

for silcone prostheses

X-Line (standard spherical abutment)

AbutmentsLaboratory Analogues Magneto

I0201X350I0201X500I0201X650I0201X800 E0004X1 M0001X900

35 5 65 8

for silcone prostheses

U0002Z315

U0002X265

for silcone prostheses

U0002X265K

with collar

U0001X265R

for acrylic prostheses

U0001X265K

with collar

A0001X555

Orbita

A0002X265

Auricular Nasal

T-Line (Telescopic abutment)

reg Magnetic Retention Steco Titanmagnetics for IE

OslashNOTE See page 20-23 for more information on Steco Titanmagnetics prosthetics and instrumentation

08

Medium Bone

Oslash375mm Parallel Walled (IE3) 3mm length

4mm length

6mm length

Oslash20mm

Oslash30mm

D-RB-M

S

Medium Bone

Oslash375mm Parallel Walled (IE4)

Oslash20mm

Oslash30mm

D-RB-M

S

Oslash375mm Parallel Walled (IE6)

Soft Bone

Oslash20mm

D-RB-M

S

Soft Bone

Oslash20mm

D-RB-M

S

Soft Bone

Oslash20mm

D-RB-M

S

Dense Bone

Oslash20mm

Oslash30mm

D-RB-M

S

Dense Bone

Oslash20mm

Oslash30mm

D-RB-M

S

Medium Bone

Oslash20mm

Oslash30mm

D-RB-M

S

Dense Bone

Oslash20mm

Oslash30mm

D-RB-M

S

D-TAP-IB

S

D-TAP-IB

S

D-TAP-IB

S

Medium Bone

Oslash40mm Tapered (IET4 IET 4)i

Soft Bone

Oslash20mm

D-RB-M

S

Dense Bone

Oslash20mm

Oslash40mm

D-RB-M

S

Oslash20mm

Oslash40mm

D-RB-M

S

NOTE The total implant length is reached when the flange of the 4mm tapered drill touches the bone surface Drilling beyond this point may compromise primary stability of the implant

4mm length

Site Preparation SequenceSite Preparation SequenceSite Preparation Sequence

IET4

09

Most instruments are available in various lengths

IET 4i

I-WI-CST I-WI-SS

(Internal Drive)

Oslash45mm Tapered (IETi4)

INSTRUMENTATION

Wrench Converters

Wrench Converters

Insertion Tools

I-HIDU-S M L I-WIID-S LI-HID-S M L

Handpiece InsertUniversal

Wrench InsertHandpiece Insertwith WampH

I-WI-CST I-WI-SH

IE4IE3 IE6

Fixture Mounted Implants (Parallel Walled amp Tapered)

Internal Drive Implant (Tapered)

Insertion Tools

I-CON-X

Fixture Mount Driver

(With WampH)

Fixture Mount Universal Driver(Without WampH)

I-CONU-X

For Handpiece inserts (Latch-type)

featuring the WampH hex

For HEX connection of fixture mounts

For Handpiece inserts (Latch-type) featuring the WampH hex

For SQUARE connection of fixture mounts

and instruments

PLACEMENT TOOLS DRILLS DRIVERS

10

IE3

IE4

IE6

IET

I-EO-EG For surgical placement of Extraoral ImplantsI-EO-EG

INSTRUMENT TRAY

Pilot DrillD-RB-MS

Oslash20mmTwist Drills

Final Twist Drills

Final Tapered Drill

Placement Tools

D-20E-03F

D-20E-04F

D-20E-06F

D-30E-03F

D-30E-04F

D-30E-06F

D-40E-04F

I-CON-X XS

I-CONU-X XS

Handpiece Insert

Convert latch type instrument with the WampH hex to fit with square connection

Torque wrench

Converter

Drill Extensions

I-WI-C-S L

I-DE-G

I-DE-K

(Optional)

Bone Tap

D-TAP-IBS

(Optional)

I-WI-AWrench Insert

Standard Abutment Drivers(Hex)

I-AD

I-HAD

Handheld

Handpiece Insert

I-HID-S M L

Internal Drive

Handpiece Insert

I-WIID-S LInternal Drive

Wrench Insert

Hex Drivers (122mm)

I-HD-SMLHandheld

I-HHD-22SMLHandpiece Insert

I-WI-22SMLWrench Insert

Cover Screw Drivers(09mm)

I-CS-HD L

I-HHD-09

I-WI-09

09mm Hex

Handheld

Handpiece Insert

Wrench Insert

11

Flat Spanner

I-SP-X (System specific)

I-TWS-B45 I-TWS-B100

I-TWS

Wrench Torque Attachments

Wrench Converters

I-WI-CST

For Handpiece inserts (Latch-type)

featuring the WampH hex

I-WI-SL

For Handpiece inserts (Latch-type)

without the WampH hex

I-WI-SS

For SQUARE connection of fixture mounts

and instruments

I-WI-SH

For HEX connection of fixture mounts

All instruments and tooling used during the procedure must be maintained in good condition and cleaned and sterilized prior to to use Please consult the Southern Implants

Cleaning and Sterilization Procedure Guidelines (CAT-1039) for guidance concerning the maintenance of drills instruments and surgical trays

NOTE

Most Instruments available in Short Medium Long

The surgical kit has an intuitive layout to guide the surgeon through the drill sequence

For Polishing Protector Caps refer to CAT-1010

12

NOTE Refer to CAT-1203 for alternative drivers

UNIVERSAL 122127 UNIVERSAL 122127UNIVERSAL 122127

HANDHELD HANDPIECE WRENCH

I-HD-SML

122 122122

I-HHD-22SML I-WI-22SMLI-HHD-22U-SMLI-HD-22U-SML I-WI-22U-SML

DRIVER AND SCREW INFORMATION

I-UGI-SML I-HUG-SML I-WI-UG-SML

UNIGRIP Drivers

Alternative Drivers

Hex Drivers

Laboratory Screw

1 Series Screws

TORQUE 10-15Ncm

Head Diameter 225mm

122 Hex 122 HexUnigrip

TSH1GSH1

TSU1GSU1 (Blackened and for

laboratory use only)

BSH1

NOTE bull Due to design revisions screw tips may be flat or rounded

bull Always ensure that the correct screw is used for the relevant implant and component

Screw Head Connections

Hex Unigrip

STECO TITANMAGNETICS

Dual magnet system The construction principle

Sm2Co1

7 Magnet

Implant-specific geometry

Corrosion-proof titanium housing

Prostheses magnet

Insert Attachment

Magnetic attachments for facial prosthesis

The universal and easily manageable solution for implant-supported face prostheses and obturators

bull Refer to CAT-1003 for alternative slotted 1 Series screws

Two open magnet fields exert a force of attraction over a longer distance than mono-magnet systems

13

STECO TITANMAGNETICS

Oslash480 Oslash580

Height

265 mmHeight

315 mmProstheses magnet

Insert Attachment

30 N (300 g)Withdrawal force16 N (163 g)

X-Line Z-Line

reg The slightly curved surface of the spherical StecoTitanmagnetics X-Line and the Z-Line facilitates self centering and has the lowest lateral force introduction into the implant X-Line and Z-Line are therefore particularly suitable for short implants Due to the absence of lateral steering they are also indicated for highly divergent implants

Spherical magnets

T-Line

reg The StecoTitanmagnetics T-Line was developed exclusively for extraoral use The telescopic bearing of 25 mm gives the facial prosthesis secure fixation on the tissue The design allows a certain amount of rotation and axial movement without losing the withdrawal force

Telescopic magnets

Oslash580

Distance height

Distance height

Distance height

Height

57 mm

14 N (143 g)

Prosthesis magnet

Withdrawal force

Insert Attachment

Prosthetic Components

In X-Line and Z-Line there are prostheses magnets for acrylic and with additional retention for silicone For more lateral support there are prostheses magnets with extended collars available

For silicone

with collar and retention ring

with retention ring with rotation protection with collar

For acrylicFor silicone For acrylic

Universalwith retention ring

In the T-Line there are also prostheses magnets for acrylic and with additional retention for silicone

Accessories

To make a new prostheses each product line has its own compatible impression copings and laboratory analogues

Impression Copings- magnetic impression without screws- lock magnetically to the insert- the external geometry ensures the impression material is securely fi xed

Z-Line T-LineX-Line

Laboratory Analogues- for making models quickly and hygienically- the original implant does not have to be used on the insertion point of an analogue

- there is no need for time-consuming cleaning- a length of 16 mm is also available on request

Z-Line T-LineX-Line

The Healing-Flange is placed on the insert to stabilize the bandage on fresh skin perforation tissue after application of the insert This minimizes excessive tissue proliferation The Healing-Flange has its own magnet core and is made off tissue friendly Titanium

Healing Flange

X-Line T-Line

Insertion standard tools

X-Line

H0004X2

Connector to handpiece

H0004X4

H0004X1

Connector to ratchet

Z-Line amp T-Line

H0004T2

Connector to handpiece

Connector to ratchet

H0004T4

H0004T1

Connector to I-Ratchet-2Connector to I-Ratchet-2

14

APEXDIAMETER

PLATFORM DIAMETER

PLATFORM DIAMETER (flange)

MAJOR DIAMETER

COLLAR HEIGHT

THREADPITCH

APEXDIAMETER

THREADPITCH

COLLAR HEIGHT

HEXHEIGHT

HEXWIDTH

ProstheticColourCode

PLATFORM DIAMETER

(flange)

MAJOR DIAMETER

IE

IET

IETi

375

45

45

480

407

407

270

270

270

040 280

245

245

Cylindricalor Tapered

CT 63 4

radic

radic

radic

radic radic06

05

05

025

025

07

07

07

C

T

T

Oslash375mm

Oslash45mm

Oslash45mm

RANGE IMPLANT LENGTHS

IMPLANT DIMENSIONS AND INFORMATION

The following symbols are used on our packaging labels and they indicate the following

1

3

4

6

7

6

AMERICAS ASIA Southern Implants North America Inc 225 Chimney Corner Lane Suite 3011 Jupiter FL 33458 United States of America

Southern Implants UK Ltd Building 3 Chiswick Park566 Chiswick High Road London W4 5YA United KingdomEC REP

1 Albert Rd IRENE 0062 South AfricaSouthern Implants (Pty) Ltd

22797

STERILIZE2

only

yyyy-mm

LOTLOT

5

IET4

IET4

IET4

Doc 0000-0 Rev 0

IET4

REF

REF

REF

REF

(01) 00000000000000(17) Date packed(10) Expiry Date

Ext Hex Tapered Implant Ultra-Short Oslash45 x 4mm

Oslash45 x 4mm Oslash45 x 4mm

Manufacturer1

2

3

4

7

55

6

STERILE R

Implant details and size

Implant image

Sterilization using Irradiation

Caution

CE mark and notified body number

Expiry date

Prescription device

ii

STERILE R

22

STERILIZE2

STERILIZE2 Do not Resterilize

Consult instruction for use

Do not reuse

Sterile unless package is opened or damaged

CAUTION FEDERAL LAW RESTRICTS THE DEVICE TO SALE BY OR ON THE ORDER OF A LICENCED HEALTH CARE PROVIDER

Patient sticker for documentation purposes(to be used by health care provider on patient file)

2D Bar codingContains the GTIN Expiry Date and LOT Number

EXPLANATION OF SYMBOLS

15

copy2019 Southern Implants (Pty) Ltd All rights reserved Co-Axis Southern Implantsand Subcrestal Angle Correctionare registered trademarks and Body-Shift INVERTA and PROVATA are trademarks of Southern Implants (Pty) Ltd Not all implants are available in all markets

CAT-2010-08 (C1073)

For more information please contact your Southern Implants Representative or visit southernimplantscom

Subsidiaries

AustraliaSouthern Implants AustraliaT +61-2-8076-9337E infosouthernimplantscomau

United KingdomSouthern Implants UKT +44-20-8899-6845 6 7E infosouthernimplantscouk

USA and CanadaSouthern Implants North America IncT +1-561-472-0990E customercaresouthernimplantscom

South Africa ndash Headquarters 1 Albert Road Irene RSAT +27-12-667-1046 | E infosouthernimplantscom

Southern Implants Products are distributed world-wide please visit southernimplantscom for a list of Distributors

  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • Page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Page 15
  • Page 16

08

Medium Bone

Oslash375mm Parallel Walled (IE3) 3mm length

4mm length

6mm length

Oslash20mm

Oslash30mm

D-RB-M

S

Medium Bone

Oslash375mm Parallel Walled (IE4)

Oslash20mm

Oslash30mm

D-RB-M

S

Oslash375mm Parallel Walled (IE6)

Soft Bone

Oslash20mm

D-RB-M

S

Soft Bone

Oslash20mm

D-RB-M

S

Soft Bone

Oslash20mm

D-RB-M

S

Dense Bone

Oslash20mm

Oslash30mm

D-RB-M

S

Dense Bone

Oslash20mm

Oslash30mm

D-RB-M

S

Medium Bone

Oslash20mm

Oslash30mm

D-RB-M

S

Dense Bone

Oslash20mm

Oslash30mm

D-RB-M

S

D-TAP-IB

S

D-TAP-IB

S

D-TAP-IB

S

Medium Bone

Oslash40mm Tapered (IET4 IET 4)i

Soft Bone

Oslash20mm

D-RB-M

S

Dense Bone

Oslash20mm

Oslash40mm

D-RB-M

S

Oslash20mm

Oslash40mm

D-RB-M

S

NOTE The total implant length is reached when the flange of the 4mm tapered drill touches the bone surface Drilling beyond this point may compromise primary stability of the implant

4mm length

Site Preparation SequenceSite Preparation SequenceSite Preparation Sequence

IET4

09

Most instruments are available in various lengths

IET 4i

I-WI-CST I-WI-SS

(Internal Drive)

Oslash45mm Tapered (IETi4)

INSTRUMENTATION

Wrench Converters

Wrench Converters

Insertion Tools

I-HIDU-S M L I-WIID-S LI-HID-S M L

Handpiece InsertUniversal

Wrench InsertHandpiece Insertwith WampH

I-WI-CST I-WI-SH

IE4IE3 IE6

Fixture Mounted Implants (Parallel Walled amp Tapered)

Internal Drive Implant (Tapered)

Insertion Tools

I-CON-X

Fixture Mount Driver

(With WampH)

Fixture Mount Universal Driver(Without WampH)

I-CONU-X

For Handpiece inserts (Latch-type)

featuring the WampH hex

For HEX connection of fixture mounts

For Handpiece inserts (Latch-type) featuring the WampH hex

For SQUARE connection of fixture mounts

and instruments

PLACEMENT TOOLS DRILLS DRIVERS

10

IE3

IE4

IE6

IET

I-EO-EG For surgical placement of Extraoral ImplantsI-EO-EG

INSTRUMENT TRAY

Pilot DrillD-RB-MS

Oslash20mmTwist Drills

Final Twist Drills

Final Tapered Drill

Placement Tools

D-20E-03F

D-20E-04F

D-20E-06F

D-30E-03F

D-30E-04F

D-30E-06F

D-40E-04F

I-CON-X XS

I-CONU-X XS

Handpiece Insert

Convert latch type instrument with the WampH hex to fit with square connection

Torque wrench

Converter

Drill Extensions

I-WI-C-S L

I-DE-G

I-DE-K

(Optional)

Bone Tap

D-TAP-IBS

(Optional)

I-WI-AWrench Insert

Standard Abutment Drivers(Hex)

I-AD

I-HAD

Handheld

Handpiece Insert

I-HID-S M L

Internal Drive

Handpiece Insert

I-WIID-S LInternal Drive

Wrench Insert

Hex Drivers (122mm)

I-HD-SMLHandheld

I-HHD-22SMLHandpiece Insert

I-WI-22SMLWrench Insert

Cover Screw Drivers(09mm)

I-CS-HD L

I-HHD-09

I-WI-09

09mm Hex

Handheld

Handpiece Insert

Wrench Insert

11

Flat Spanner

I-SP-X (System specific)

I-TWS-B45 I-TWS-B100

I-TWS

Wrench Torque Attachments

Wrench Converters

I-WI-CST

For Handpiece inserts (Latch-type)

featuring the WampH hex

I-WI-SL

For Handpiece inserts (Latch-type)

without the WampH hex

I-WI-SS

For SQUARE connection of fixture mounts

and instruments

I-WI-SH

For HEX connection of fixture mounts

All instruments and tooling used during the procedure must be maintained in good condition and cleaned and sterilized prior to to use Please consult the Southern Implants

Cleaning and Sterilization Procedure Guidelines (CAT-1039) for guidance concerning the maintenance of drills instruments and surgical trays

NOTE

Most Instruments available in Short Medium Long

The surgical kit has an intuitive layout to guide the surgeon through the drill sequence

For Polishing Protector Caps refer to CAT-1010

12

NOTE Refer to CAT-1203 for alternative drivers

UNIVERSAL 122127 UNIVERSAL 122127UNIVERSAL 122127

HANDHELD HANDPIECE WRENCH

I-HD-SML

122 122122

I-HHD-22SML I-WI-22SMLI-HHD-22U-SMLI-HD-22U-SML I-WI-22U-SML

DRIVER AND SCREW INFORMATION

I-UGI-SML I-HUG-SML I-WI-UG-SML

UNIGRIP Drivers

Alternative Drivers

Hex Drivers

Laboratory Screw

1 Series Screws

TORQUE 10-15Ncm

Head Diameter 225mm

122 Hex 122 HexUnigrip

TSH1GSH1

TSU1GSU1 (Blackened and for

laboratory use only)

BSH1

NOTE bull Due to design revisions screw tips may be flat or rounded

bull Always ensure that the correct screw is used for the relevant implant and component

Screw Head Connections

Hex Unigrip

STECO TITANMAGNETICS

Dual magnet system The construction principle

Sm2Co1

7 Magnet

Implant-specific geometry

Corrosion-proof titanium housing

Prostheses magnet

Insert Attachment

Magnetic attachments for facial prosthesis

The universal and easily manageable solution for implant-supported face prostheses and obturators

bull Refer to CAT-1003 for alternative slotted 1 Series screws

Two open magnet fields exert a force of attraction over a longer distance than mono-magnet systems

13

STECO TITANMAGNETICS

Oslash480 Oslash580

Height

265 mmHeight

315 mmProstheses magnet

Insert Attachment

30 N (300 g)Withdrawal force16 N (163 g)

X-Line Z-Line

reg The slightly curved surface of the spherical StecoTitanmagnetics X-Line and the Z-Line facilitates self centering and has the lowest lateral force introduction into the implant X-Line and Z-Line are therefore particularly suitable for short implants Due to the absence of lateral steering they are also indicated for highly divergent implants

Spherical magnets

T-Line

reg The StecoTitanmagnetics T-Line was developed exclusively for extraoral use The telescopic bearing of 25 mm gives the facial prosthesis secure fixation on the tissue The design allows a certain amount of rotation and axial movement without losing the withdrawal force

Telescopic magnets

Oslash580

Distance height

Distance height

Distance height

Height

57 mm

14 N (143 g)

Prosthesis magnet

Withdrawal force

Insert Attachment

Prosthetic Components

In X-Line and Z-Line there are prostheses magnets for acrylic and with additional retention for silicone For more lateral support there are prostheses magnets with extended collars available

For silicone

with collar and retention ring

with retention ring with rotation protection with collar

For acrylicFor silicone For acrylic

Universalwith retention ring

In the T-Line there are also prostheses magnets for acrylic and with additional retention for silicone

Accessories

To make a new prostheses each product line has its own compatible impression copings and laboratory analogues

Impression Copings- magnetic impression without screws- lock magnetically to the insert- the external geometry ensures the impression material is securely fi xed

Z-Line T-LineX-Line

Laboratory Analogues- for making models quickly and hygienically- the original implant does not have to be used on the insertion point of an analogue

- there is no need for time-consuming cleaning- a length of 16 mm is also available on request

Z-Line T-LineX-Line

The Healing-Flange is placed on the insert to stabilize the bandage on fresh skin perforation tissue after application of the insert This minimizes excessive tissue proliferation The Healing-Flange has its own magnet core and is made off tissue friendly Titanium

Healing Flange

X-Line T-Line

Insertion standard tools

X-Line

H0004X2

Connector to handpiece

H0004X4

H0004X1

Connector to ratchet

Z-Line amp T-Line

H0004T2

Connector to handpiece

Connector to ratchet

H0004T4

H0004T1

Connector to I-Ratchet-2Connector to I-Ratchet-2

14

APEXDIAMETER

PLATFORM DIAMETER

PLATFORM DIAMETER (flange)

MAJOR DIAMETER

COLLAR HEIGHT

THREADPITCH

APEXDIAMETER

THREADPITCH

COLLAR HEIGHT

HEXHEIGHT

HEXWIDTH

ProstheticColourCode

PLATFORM DIAMETER

(flange)

MAJOR DIAMETER

IE

IET

IETi

375

45

45

480

407

407

270

270

270

040 280

245

245

Cylindricalor Tapered

CT 63 4

radic

radic

radic

radic radic06

05

05

025

025

07

07

07

C

T

T

Oslash375mm

Oslash45mm

Oslash45mm

RANGE IMPLANT LENGTHS

IMPLANT DIMENSIONS AND INFORMATION

The following symbols are used on our packaging labels and they indicate the following

1

3

4

6

7

6

AMERICAS ASIA Southern Implants North America Inc 225 Chimney Corner Lane Suite 3011 Jupiter FL 33458 United States of America

Southern Implants UK Ltd Building 3 Chiswick Park566 Chiswick High Road London W4 5YA United KingdomEC REP

1 Albert Rd IRENE 0062 South AfricaSouthern Implants (Pty) Ltd

22797

STERILIZE2

only

yyyy-mm

LOTLOT

5

IET4

IET4

IET4

Doc 0000-0 Rev 0

IET4

REF

REF

REF

REF

(01) 00000000000000(17) Date packed(10) Expiry Date

Ext Hex Tapered Implant Ultra-Short Oslash45 x 4mm

Oslash45 x 4mm Oslash45 x 4mm

Manufacturer1

2

3

4

7

55

6

STERILE R

Implant details and size

Implant image

Sterilization using Irradiation

Caution

CE mark and notified body number

Expiry date

Prescription device

ii

STERILE R

22

STERILIZE2

STERILIZE2 Do not Resterilize

Consult instruction for use

Do not reuse

Sterile unless package is opened or damaged

CAUTION FEDERAL LAW RESTRICTS THE DEVICE TO SALE BY OR ON THE ORDER OF A LICENCED HEALTH CARE PROVIDER

Patient sticker for documentation purposes(to be used by health care provider on patient file)

2D Bar codingContains the GTIN Expiry Date and LOT Number

EXPLANATION OF SYMBOLS

15

copy2019 Southern Implants (Pty) Ltd All rights reserved Co-Axis Southern Implantsand Subcrestal Angle Correctionare registered trademarks and Body-Shift INVERTA and PROVATA are trademarks of Southern Implants (Pty) Ltd Not all implants are available in all markets

CAT-2010-08 (C1073)

For more information please contact your Southern Implants Representative or visit southernimplantscom

Subsidiaries

AustraliaSouthern Implants AustraliaT +61-2-8076-9337E infosouthernimplantscomau

United KingdomSouthern Implants UKT +44-20-8899-6845 6 7E infosouthernimplantscouk

USA and CanadaSouthern Implants North America IncT +1-561-472-0990E customercaresouthernimplantscom

South Africa ndash Headquarters 1 Albert Road Irene RSAT +27-12-667-1046 | E infosouthernimplantscom

Southern Implants Products are distributed world-wide please visit southernimplantscom for a list of Distributors

  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • Page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Page 15
  • Page 16

IET4

09

Most instruments are available in various lengths

IET 4i

I-WI-CST I-WI-SS

(Internal Drive)

Oslash45mm Tapered (IETi4)

INSTRUMENTATION

Wrench Converters

Wrench Converters

Insertion Tools

I-HIDU-S M L I-WIID-S LI-HID-S M L

Handpiece InsertUniversal

Wrench InsertHandpiece Insertwith WampH

I-WI-CST I-WI-SH

IE4IE3 IE6

Fixture Mounted Implants (Parallel Walled amp Tapered)

Internal Drive Implant (Tapered)

Insertion Tools

I-CON-X

Fixture Mount Driver

(With WampH)

Fixture Mount Universal Driver(Without WampH)

I-CONU-X

For Handpiece inserts (Latch-type)

featuring the WampH hex

For HEX connection of fixture mounts

For Handpiece inserts (Latch-type) featuring the WampH hex

For SQUARE connection of fixture mounts

and instruments

PLACEMENT TOOLS DRILLS DRIVERS

10

IE3

IE4

IE6

IET

I-EO-EG For surgical placement of Extraoral ImplantsI-EO-EG

INSTRUMENT TRAY

Pilot DrillD-RB-MS

Oslash20mmTwist Drills

Final Twist Drills

Final Tapered Drill

Placement Tools

D-20E-03F

D-20E-04F

D-20E-06F

D-30E-03F

D-30E-04F

D-30E-06F

D-40E-04F

I-CON-X XS

I-CONU-X XS

Handpiece Insert

Convert latch type instrument with the WampH hex to fit with square connection

Torque wrench

Converter

Drill Extensions

I-WI-C-S L

I-DE-G

I-DE-K

(Optional)

Bone Tap

D-TAP-IBS

(Optional)

I-WI-AWrench Insert

Standard Abutment Drivers(Hex)

I-AD

I-HAD

Handheld

Handpiece Insert

I-HID-S M L

Internal Drive

Handpiece Insert

I-WIID-S LInternal Drive

Wrench Insert

Hex Drivers (122mm)

I-HD-SMLHandheld

I-HHD-22SMLHandpiece Insert

I-WI-22SMLWrench Insert

Cover Screw Drivers(09mm)

I-CS-HD L

I-HHD-09

I-WI-09

09mm Hex

Handheld

Handpiece Insert

Wrench Insert

11

Flat Spanner

I-SP-X (System specific)

I-TWS-B45 I-TWS-B100

I-TWS

Wrench Torque Attachments

Wrench Converters

I-WI-CST

For Handpiece inserts (Latch-type)

featuring the WampH hex

I-WI-SL

For Handpiece inserts (Latch-type)

without the WampH hex

I-WI-SS

For SQUARE connection of fixture mounts

and instruments

I-WI-SH

For HEX connection of fixture mounts

All instruments and tooling used during the procedure must be maintained in good condition and cleaned and sterilized prior to to use Please consult the Southern Implants

Cleaning and Sterilization Procedure Guidelines (CAT-1039) for guidance concerning the maintenance of drills instruments and surgical trays

NOTE

Most Instruments available in Short Medium Long

The surgical kit has an intuitive layout to guide the surgeon through the drill sequence

For Polishing Protector Caps refer to CAT-1010

12

NOTE Refer to CAT-1203 for alternative drivers

UNIVERSAL 122127 UNIVERSAL 122127UNIVERSAL 122127

HANDHELD HANDPIECE WRENCH

I-HD-SML

122 122122

I-HHD-22SML I-WI-22SMLI-HHD-22U-SMLI-HD-22U-SML I-WI-22U-SML

DRIVER AND SCREW INFORMATION

I-UGI-SML I-HUG-SML I-WI-UG-SML

UNIGRIP Drivers

Alternative Drivers

Hex Drivers

Laboratory Screw

1 Series Screws

TORQUE 10-15Ncm

Head Diameter 225mm

122 Hex 122 HexUnigrip

TSH1GSH1

TSU1GSU1 (Blackened and for

laboratory use only)

BSH1

NOTE bull Due to design revisions screw tips may be flat or rounded

bull Always ensure that the correct screw is used for the relevant implant and component

Screw Head Connections

Hex Unigrip

STECO TITANMAGNETICS

Dual magnet system The construction principle

Sm2Co1

7 Magnet

Implant-specific geometry

Corrosion-proof titanium housing

Prostheses magnet

Insert Attachment

Magnetic attachments for facial prosthesis

The universal and easily manageable solution for implant-supported face prostheses and obturators

bull Refer to CAT-1003 for alternative slotted 1 Series screws

Two open magnet fields exert a force of attraction over a longer distance than mono-magnet systems

13

STECO TITANMAGNETICS

Oslash480 Oslash580

Height

265 mmHeight

315 mmProstheses magnet

Insert Attachment

30 N (300 g)Withdrawal force16 N (163 g)

X-Line Z-Line

reg The slightly curved surface of the spherical StecoTitanmagnetics X-Line and the Z-Line facilitates self centering and has the lowest lateral force introduction into the implant X-Line and Z-Line are therefore particularly suitable for short implants Due to the absence of lateral steering they are also indicated for highly divergent implants

Spherical magnets

T-Line

reg The StecoTitanmagnetics T-Line was developed exclusively for extraoral use The telescopic bearing of 25 mm gives the facial prosthesis secure fixation on the tissue The design allows a certain amount of rotation and axial movement without losing the withdrawal force

Telescopic magnets

Oslash580

Distance height

Distance height

Distance height

Height

57 mm

14 N (143 g)

Prosthesis magnet

Withdrawal force

Insert Attachment

Prosthetic Components

In X-Line and Z-Line there are prostheses magnets for acrylic and with additional retention for silicone For more lateral support there are prostheses magnets with extended collars available

For silicone

with collar and retention ring

with retention ring with rotation protection with collar

For acrylicFor silicone For acrylic

Universalwith retention ring

In the T-Line there are also prostheses magnets for acrylic and with additional retention for silicone

Accessories

To make a new prostheses each product line has its own compatible impression copings and laboratory analogues

Impression Copings- magnetic impression without screws- lock magnetically to the insert- the external geometry ensures the impression material is securely fi xed

Z-Line T-LineX-Line

Laboratory Analogues- for making models quickly and hygienically- the original implant does not have to be used on the insertion point of an analogue

- there is no need for time-consuming cleaning- a length of 16 mm is also available on request

Z-Line T-LineX-Line

The Healing-Flange is placed on the insert to stabilize the bandage on fresh skin perforation tissue after application of the insert This minimizes excessive tissue proliferation The Healing-Flange has its own magnet core and is made off tissue friendly Titanium

Healing Flange

X-Line T-Line

Insertion standard tools

X-Line

H0004X2

Connector to handpiece

H0004X4

H0004X1

Connector to ratchet

Z-Line amp T-Line

H0004T2

Connector to handpiece

Connector to ratchet

H0004T4

H0004T1

Connector to I-Ratchet-2Connector to I-Ratchet-2

14

APEXDIAMETER

PLATFORM DIAMETER

PLATFORM DIAMETER (flange)

MAJOR DIAMETER

COLLAR HEIGHT

THREADPITCH

APEXDIAMETER

THREADPITCH

COLLAR HEIGHT

HEXHEIGHT

HEXWIDTH

ProstheticColourCode

PLATFORM DIAMETER

(flange)

MAJOR DIAMETER

IE

IET

IETi

375

45

45

480

407

407

270

270

270

040 280

245

245

Cylindricalor Tapered

CT 63 4

radic

radic

radic

radic radic06

05

05

025

025

07

07

07

C

T

T

Oslash375mm

Oslash45mm

Oslash45mm

RANGE IMPLANT LENGTHS

IMPLANT DIMENSIONS AND INFORMATION

The following symbols are used on our packaging labels and they indicate the following

1

3

4

6

7

6

AMERICAS ASIA Southern Implants North America Inc 225 Chimney Corner Lane Suite 3011 Jupiter FL 33458 United States of America

Southern Implants UK Ltd Building 3 Chiswick Park566 Chiswick High Road London W4 5YA United KingdomEC REP

1 Albert Rd IRENE 0062 South AfricaSouthern Implants (Pty) Ltd

22797

STERILIZE2

only

yyyy-mm

LOTLOT

5

IET4

IET4

IET4

Doc 0000-0 Rev 0

IET4

REF

REF

REF

REF

(01) 00000000000000(17) Date packed(10) Expiry Date

Ext Hex Tapered Implant Ultra-Short Oslash45 x 4mm

Oslash45 x 4mm Oslash45 x 4mm

Manufacturer1

2

3

4

7

55

6

STERILE R

Implant details and size

Implant image

Sterilization using Irradiation

Caution

CE mark and notified body number

Expiry date

Prescription device

ii

STERILE R

22

STERILIZE2

STERILIZE2 Do not Resterilize

Consult instruction for use

Do not reuse

Sterile unless package is opened or damaged

CAUTION FEDERAL LAW RESTRICTS THE DEVICE TO SALE BY OR ON THE ORDER OF A LICENCED HEALTH CARE PROVIDER

Patient sticker for documentation purposes(to be used by health care provider on patient file)

2D Bar codingContains the GTIN Expiry Date and LOT Number

EXPLANATION OF SYMBOLS

15

copy2019 Southern Implants (Pty) Ltd All rights reserved Co-Axis Southern Implantsand Subcrestal Angle Correctionare registered trademarks and Body-Shift INVERTA and PROVATA are trademarks of Southern Implants (Pty) Ltd Not all implants are available in all markets

CAT-2010-08 (C1073)

For more information please contact your Southern Implants Representative or visit southernimplantscom

Subsidiaries

AustraliaSouthern Implants AustraliaT +61-2-8076-9337E infosouthernimplantscomau

United KingdomSouthern Implants UKT +44-20-8899-6845 6 7E infosouthernimplantscouk

USA and CanadaSouthern Implants North America IncT +1-561-472-0990E customercaresouthernimplantscom

South Africa ndash Headquarters 1 Albert Road Irene RSAT +27-12-667-1046 | E infosouthernimplantscom

Southern Implants Products are distributed world-wide please visit southernimplantscom for a list of Distributors

  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • Page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Page 15
  • Page 16

PLACEMENT TOOLS DRILLS DRIVERS

10

IE3

IE4

IE6

IET

I-EO-EG For surgical placement of Extraoral ImplantsI-EO-EG

INSTRUMENT TRAY

Pilot DrillD-RB-MS

Oslash20mmTwist Drills

Final Twist Drills

Final Tapered Drill

Placement Tools

D-20E-03F

D-20E-04F

D-20E-06F

D-30E-03F

D-30E-04F

D-30E-06F

D-40E-04F

I-CON-X XS

I-CONU-X XS

Handpiece Insert

Convert latch type instrument with the WampH hex to fit with square connection

Torque wrench

Converter

Drill Extensions

I-WI-C-S L

I-DE-G

I-DE-K

(Optional)

Bone Tap

D-TAP-IBS

(Optional)

I-WI-AWrench Insert

Standard Abutment Drivers(Hex)

I-AD

I-HAD

Handheld

Handpiece Insert

I-HID-S M L

Internal Drive

Handpiece Insert

I-WIID-S LInternal Drive

Wrench Insert

Hex Drivers (122mm)

I-HD-SMLHandheld

I-HHD-22SMLHandpiece Insert

I-WI-22SMLWrench Insert

Cover Screw Drivers(09mm)

I-CS-HD L

I-HHD-09

I-WI-09

09mm Hex

Handheld

Handpiece Insert

Wrench Insert

11

Flat Spanner

I-SP-X (System specific)

I-TWS-B45 I-TWS-B100

I-TWS

Wrench Torque Attachments

Wrench Converters

I-WI-CST

For Handpiece inserts (Latch-type)

featuring the WampH hex

I-WI-SL

For Handpiece inserts (Latch-type)

without the WampH hex

I-WI-SS

For SQUARE connection of fixture mounts

and instruments

I-WI-SH

For HEX connection of fixture mounts

All instruments and tooling used during the procedure must be maintained in good condition and cleaned and sterilized prior to to use Please consult the Southern Implants

Cleaning and Sterilization Procedure Guidelines (CAT-1039) for guidance concerning the maintenance of drills instruments and surgical trays

NOTE

Most Instruments available in Short Medium Long

The surgical kit has an intuitive layout to guide the surgeon through the drill sequence

For Polishing Protector Caps refer to CAT-1010

12

NOTE Refer to CAT-1203 for alternative drivers

UNIVERSAL 122127 UNIVERSAL 122127UNIVERSAL 122127

HANDHELD HANDPIECE WRENCH

I-HD-SML

122 122122

I-HHD-22SML I-WI-22SMLI-HHD-22U-SMLI-HD-22U-SML I-WI-22U-SML

DRIVER AND SCREW INFORMATION

I-UGI-SML I-HUG-SML I-WI-UG-SML

UNIGRIP Drivers

Alternative Drivers

Hex Drivers

Laboratory Screw

1 Series Screws

TORQUE 10-15Ncm

Head Diameter 225mm

122 Hex 122 HexUnigrip

TSH1GSH1

TSU1GSU1 (Blackened and for

laboratory use only)

BSH1

NOTE bull Due to design revisions screw tips may be flat or rounded

bull Always ensure that the correct screw is used for the relevant implant and component

Screw Head Connections

Hex Unigrip

STECO TITANMAGNETICS

Dual magnet system The construction principle

Sm2Co1

7 Magnet

Implant-specific geometry

Corrosion-proof titanium housing

Prostheses magnet

Insert Attachment

Magnetic attachments for facial prosthesis

The universal and easily manageable solution for implant-supported face prostheses and obturators

bull Refer to CAT-1003 for alternative slotted 1 Series screws

Two open magnet fields exert a force of attraction over a longer distance than mono-magnet systems

13

STECO TITANMAGNETICS

Oslash480 Oslash580

Height

265 mmHeight

315 mmProstheses magnet

Insert Attachment

30 N (300 g)Withdrawal force16 N (163 g)

X-Line Z-Line

reg The slightly curved surface of the spherical StecoTitanmagnetics X-Line and the Z-Line facilitates self centering and has the lowest lateral force introduction into the implant X-Line and Z-Line are therefore particularly suitable for short implants Due to the absence of lateral steering they are also indicated for highly divergent implants

Spherical magnets

T-Line

reg The StecoTitanmagnetics T-Line was developed exclusively for extraoral use The telescopic bearing of 25 mm gives the facial prosthesis secure fixation on the tissue The design allows a certain amount of rotation and axial movement without losing the withdrawal force

Telescopic magnets

Oslash580

Distance height

Distance height

Distance height

Height

57 mm

14 N (143 g)

Prosthesis magnet

Withdrawal force

Insert Attachment

Prosthetic Components

In X-Line and Z-Line there are prostheses magnets for acrylic and with additional retention for silicone For more lateral support there are prostheses magnets with extended collars available

For silicone

with collar and retention ring

with retention ring with rotation protection with collar

For acrylicFor silicone For acrylic

Universalwith retention ring

In the T-Line there are also prostheses magnets for acrylic and with additional retention for silicone

Accessories

To make a new prostheses each product line has its own compatible impression copings and laboratory analogues

Impression Copings- magnetic impression without screws- lock magnetically to the insert- the external geometry ensures the impression material is securely fi xed

Z-Line T-LineX-Line

Laboratory Analogues- for making models quickly and hygienically- the original implant does not have to be used on the insertion point of an analogue

- there is no need for time-consuming cleaning- a length of 16 mm is also available on request

Z-Line T-LineX-Line

The Healing-Flange is placed on the insert to stabilize the bandage on fresh skin perforation tissue after application of the insert This minimizes excessive tissue proliferation The Healing-Flange has its own magnet core and is made off tissue friendly Titanium

Healing Flange

X-Line T-Line

Insertion standard tools

X-Line

H0004X2

Connector to handpiece

H0004X4

H0004X1

Connector to ratchet

Z-Line amp T-Line

H0004T2

Connector to handpiece

Connector to ratchet

H0004T4

H0004T1

Connector to I-Ratchet-2Connector to I-Ratchet-2

14

APEXDIAMETER

PLATFORM DIAMETER

PLATFORM DIAMETER (flange)

MAJOR DIAMETER

COLLAR HEIGHT

THREADPITCH

APEXDIAMETER

THREADPITCH

COLLAR HEIGHT

HEXHEIGHT

HEXWIDTH

ProstheticColourCode

PLATFORM DIAMETER

(flange)

MAJOR DIAMETER

IE

IET

IETi

375

45

45

480

407

407

270

270

270

040 280

245

245

Cylindricalor Tapered

CT 63 4

radic

radic

radic

radic radic06

05

05

025

025

07

07

07

C

T

T

Oslash375mm

Oslash45mm

Oslash45mm

RANGE IMPLANT LENGTHS

IMPLANT DIMENSIONS AND INFORMATION

The following symbols are used on our packaging labels and they indicate the following

1

3

4

6

7

6

AMERICAS ASIA Southern Implants North America Inc 225 Chimney Corner Lane Suite 3011 Jupiter FL 33458 United States of America

Southern Implants UK Ltd Building 3 Chiswick Park566 Chiswick High Road London W4 5YA United KingdomEC REP

1 Albert Rd IRENE 0062 South AfricaSouthern Implants (Pty) Ltd

22797

STERILIZE2

only

yyyy-mm

LOTLOT

5

IET4

IET4

IET4

Doc 0000-0 Rev 0

IET4

REF

REF

REF

REF

(01) 00000000000000(17) Date packed(10) Expiry Date

Ext Hex Tapered Implant Ultra-Short Oslash45 x 4mm

Oslash45 x 4mm Oslash45 x 4mm

Manufacturer1

2

3

4

7

55

6

STERILE R

Implant details and size

Implant image

Sterilization using Irradiation

Caution

CE mark and notified body number

Expiry date

Prescription device

ii

STERILE R

22

STERILIZE2

STERILIZE2 Do not Resterilize

Consult instruction for use

Do not reuse

Sterile unless package is opened or damaged

CAUTION FEDERAL LAW RESTRICTS THE DEVICE TO SALE BY OR ON THE ORDER OF A LICENCED HEALTH CARE PROVIDER

Patient sticker for documentation purposes(to be used by health care provider on patient file)

2D Bar codingContains the GTIN Expiry Date and LOT Number

EXPLANATION OF SYMBOLS

15

copy2019 Southern Implants (Pty) Ltd All rights reserved Co-Axis Southern Implantsand Subcrestal Angle Correctionare registered trademarks and Body-Shift INVERTA and PROVATA are trademarks of Southern Implants (Pty) Ltd Not all implants are available in all markets

CAT-2010-08 (C1073)

For more information please contact your Southern Implants Representative or visit southernimplantscom

Subsidiaries

AustraliaSouthern Implants AustraliaT +61-2-8076-9337E infosouthernimplantscomau

United KingdomSouthern Implants UKT +44-20-8899-6845 6 7E infosouthernimplantscouk

USA and CanadaSouthern Implants North America IncT +1-561-472-0990E customercaresouthernimplantscom

South Africa ndash Headquarters 1 Albert Road Irene RSAT +27-12-667-1046 | E infosouthernimplantscom

Southern Implants Products are distributed world-wide please visit southernimplantscom for a list of Distributors

  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • Page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Page 15
  • Page 16

11

Flat Spanner

I-SP-X (System specific)

I-TWS-B45 I-TWS-B100

I-TWS

Wrench Torque Attachments

Wrench Converters

I-WI-CST

For Handpiece inserts (Latch-type)

featuring the WampH hex

I-WI-SL

For Handpiece inserts (Latch-type)

without the WampH hex

I-WI-SS

For SQUARE connection of fixture mounts

and instruments

I-WI-SH

For HEX connection of fixture mounts

All instruments and tooling used during the procedure must be maintained in good condition and cleaned and sterilized prior to to use Please consult the Southern Implants

Cleaning and Sterilization Procedure Guidelines (CAT-1039) for guidance concerning the maintenance of drills instruments and surgical trays

NOTE

Most Instruments available in Short Medium Long

The surgical kit has an intuitive layout to guide the surgeon through the drill sequence

For Polishing Protector Caps refer to CAT-1010

12

NOTE Refer to CAT-1203 for alternative drivers

UNIVERSAL 122127 UNIVERSAL 122127UNIVERSAL 122127

HANDHELD HANDPIECE WRENCH

I-HD-SML

122 122122

I-HHD-22SML I-WI-22SMLI-HHD-22U-SMLI-HD-22U-SML I-WI-22U-SML

DRIVER AND SCREW INFORMATION

I-UGI-SML I-HUG-SML I-WI-UG-SML

UNIGRIP Drivers

Alternative Drivers

Hex Drivers

Laboratory Screw

1 Series Screws

TORQUE 10-15Ncm

Head Diameter 225mm

122 Hex 122 HexUnigrip

TSH1GSH1

TSU1GSU1 (Blackened and for

laboratory use only)

BSH1

NOTE bull Due to design revisions screw tips may be flat or rounded

bull Always ensure that the correct screw is used for the relevant implant and component

Screw Head Connections

Hex Unigrip

STECO TITANMAGNETICS

Dual magnet system The construction principle

Sm2Co1

7 Magnet

Implant-specific geometry

Corrosion-proof titanium housing

Prostheses magnet

Insert Attachment

Magnetic attachments for facial prosthesis

The universal and easily manageable solution for implant-supported face prostheses and obturators

bull Refer to CAT-1003 for alternative slotted 1 Series screws

Two open magnet fields exert a force of attraction over a longer distance than mono-magnet systems

13

STECO TITANMAGNETICS

Oslash480 Oslash580

Height

265 mmHeight

315 mmProstheses magnet

Insert Attachment

30 N (300 g)Withdrawal force16 N (163 g)

X-Line Z-Line

reg The slightly curved surface of the spherical StecoTitanmagnetics X-Line and the Z-Line facilitates self centering and has the lowest lateral force introduction into the implant X-Line and Z-Line are therefore particularly suitable for short implants Due to the absence of lateral steering they are also indicated for highly divergent implants

Spherical magnets

T-Line

reg The StecoTitanmagnetics T-Line was developed exclusively for extraoral use The telescopic bearing of 25 mm gives the facial prosthesis secure fixation on the tissue The design allows a certain amount of rotation and axial movement without losing the withdrawal force

Telescopic magnets

Oslash580

Distance height

Distance height

Distance height

Height

57 mm

14 N (143 g)

Prosthesis magnet

Withdrawal force

Insert Attachment

Prosthetic Components

In X-Line and Z-Line there are prostheses magnets for acrylic and with additional retention for silicone For more lateral support there are prostheses magnets with extended collars available

For silicone

with collar and retention ring

with retention ring with rotation protection with collar

For acrylicFor silicone For acrylic

Universalwith retention ring

In the T-Line there are also prostheses magnets for acrylic and with additional retention for silicone

Accessories

To make a new prostheses each product line has its own compatible impression copings and laboratory analogues

Impression Copings- magnetic impression without screws- lock magnetically to the insert- the external geometry ensures the impression material is securely fi xed

Z-Line T-LineX-Line

Laboratory Analogues- for making models quickly and hygienically- the original implant does not have to be used on the insertion point of an analogue

- there is no need for time-consuming cleaning- a length of 16 mm is also available on request

Z-Line T-LineX-Line

The Healing-Flange is placed on the insert to stabilize the bandage on fresh skin perforation tissue after application of the insert This minimizes excessive tissue proliferation The Healing-Flange has its own magnet core and is made off tissue friendly Titanium

Healing Flange

X-Line T-Line

Insertion standard tools

X-Line

H0004X2

Connector to handpiece

H0004X4

H0004X1

Connector to ratchet

Z-Line amp T-Line

H0004T2

Connector to handpiece

Connector to ratchet

H0004T4

H0004T1

Connector to I-Ratchet-2Connector to I-Ratchet-2

14

APEXDIAMETER

PLATFORM DIAMETER

PLATFORM DIAMETER (flange)

MAJOR DIAMETER

COLLAR HEIGHT

THREADPITCH

APEXDIAMETER

THREADPITCH

COLLAR HEIGHT

HEXHEIGHT

HEXWIDTH

ProstheticColourCode

PLATFORM DIAMETER

(flange)

MAJOR DIAMETER

IE

IET

IETi

375

45

45

480

407

407

270

270

270

040 280

245

245

Cylindricalor Tapered

CT 63 4

radic

radic

radic

radic radic06

05

05

025

025

07

07

07

C

T

T

Oslash375mm

Oslash45mm

Oslash45mm

RANGE IMPLANT LENGTHS

IMPLANT DIMENSIONS AND INFORMATION

The following symbols are used on our packaging labels and they indicate the following

1

3

4

6

7

6

AMERICAS ASIA Southern Implants North America Inc 225 Chimney Corner Lane Suite 3011 Jupiter FL 33458 United States of America

Southern Implants UK Ltd Building 3 Chiswick Park566 Chiswick High Road London W4 5YA United KingdomEC REP

1 Albert Rd IRENE 0062 South AfricaSouthern Implants (Pty) Ltd

22797

STERILIZE2

only

yyyy-mm

LOTLOT

5

IET4

IET4

IET4

Doc 0000-0 Rev 0

IET4

REF

REF

REF

REF

(01) 00000000000000(17) Date packed(10) Expiry Date

Ext Hex Tapered Implant Ultra-Short Oslash45 x 4mm

Oslash45 x 4mm Oslash45 x 4mm

Manufacturer1

2

3

4

7

55

6

STERILE R

Implant details and size

Implant image

Sterilization using Irradiation

Caution

CE mark and notified body number

Expiry date

Prescription device

ii

STERILE R

22

STERILIZE2

STERILIZE2 Do not Resterilize

Consult instruction for use

Do not reuse

Sterile unless package is opened or damaged

CAUTION FEDERAL LAW RESTRICTS THE DEVICE TO SALE BY OR ON THE ORDER OF A LICENCED HEALTH CARE PROVIDER

Patient sticker for documentation purposes(to be used by health care provider on patient file)

2D Bar codingContains the GTIN Expiry Date and LOT Number

EXPLANATION OF SYMBOLS

15

copy2019 Southern Implants (Pty) Ltd All rights reserved Co-Axis Southern Implantsand Subcrestal Angle Correctionare registered trademarks and Body-Shift INVERTA and PROVATA are trademarks of Southern Implants (Pty) Ltd Not all implants are available in all markets

CAT-2010-08 (C1073)

For more information please contact your Southern Implants Representative or visit southernimplantscom

Subsidiaries

AustraliaSouthern Implants AustraliaT +61-2-8076-9337E infosouthernimplantscomau

United KingdomSouthern Implants UKT +44-20-8899-6845 6 7E infosouthernimplantscouk

USA and CanadaSouthern Implants North America IncT +1-561-472-0990E customercaresouthernimplantscom

South Africa ndash Headquarters 1 Albert Road Irene RSAT +27-12-667-1046 | E infosouthernimplantscom

Southern Implants Products are distributed world-wide please visit southernimplantscom for a list of Distributors

  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • Page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Page 15
  • Page 16

12

NOTE Refer to CAT-1203 for alternative drivers

UNIVERSAL 122127 UNIVERSAL 122127UNIVERSAL 122127

HANDHELD HANDPIECE WRENCH

I-HD-SML

122 122122

I-HHD-22SML I-WI-22SMLI-HHD-22U-SMLI-HD-22U-SML I-WI-22U-SML

DRIVER AND SCREW INFORMATION

I-UGI-SML I-HUG-SML I-WI-UG-SML

UNIGRIP Drivers

Alternative Drivers

Hex Drivers

Laboratory Screw

1 Series Screws

TORQUE 10-15Ncm

Head Diameter 225mm

122 Hex 122 HexUnigrip

TSH1GSH1

TSU1GSU1 (Blackened and for

laboratory use only)

BSH1

NOTE bull Due to design revisions screw tips may be flat or rounded

bull Always ensure that the correct screw is used for the relevant implant and component

Screw Head Connections

Hex Unigrip

STECO TITANMAGNETICS

Dual magnet system The construction principle

Sm2Co1

7 Magnet

Implant-specific geometry

Corrosion-proof titanium housing

Prostheses magnet

Insert Attachment

Magnetic attachments for facial prosthesis

The universal and easily manageable solution for implant-supported face prostheses and obturators

bull Refer to CAT-1003 for alternative slotted 1 Series screws

Two open magnet fields exert a force of attraction over a longer distance than mono-magnet systems

13

STECO TITANMAGNETICS

Oslash480 Oslash580

Height

265 mmHeight

315 mmProstheses magnet

Insert Attachment

30 N (300 g)Withdrawal force16 N (163 g)

X-Line Z-Line

reg The slightly curved surface of the spherical StecoTitanmagnetics X-Line and the Z-Line facilitates self centering and has the lowest lateral force introduction into the implant X-Line and Z-Line are therefore particularly suitable for short implants Due to the absence of lateral steering they are also indicated for highly divergent implants

Spherical magnets

T-Line

reg The StecoTitanmagnetics T-Line was developed exclusively for extraoral use The telescopic bearing of 25 mm gives the facial prosthesis secure fixation on the tissue The design allows a certain amount of rotation and axial movement without losing the withdrawal force

Telescopic magnets

Oslash580

Distance height

Distance height

Distance height

Height

57 mm

14 N (143 g)

Prosthesis magnet

Withdrawal force

Insert Attachment

Prosthetic Components

In X-Line and Z-Line there are prostheses magnets for acrylic and with additional retention for silicone For more lateral support there are prostheses magnets with extended collars available

For silicone

with collar and retention ring

with retention ring with rotation protection with collar

For acrylicFor silicone For acrylic

Universalwith retention ring

In the T-Line there are also prostheses magnets for acrylic and with additional retention for silicone

Accessories

To make a new prostheses each product line has its own compatible impression copings and laboratory analogues

Impression Copings- magnetic impression without screws- lock magnetically to the insert- the external geometry ensures the impression material is securely fi xed

Z-Line T-LineX-Line

Laboratory Analogues- for making models quickly and hygienically- the original implant does not have to be used on the insertion point of an analogue

- there is no need for time-consuming cleaning- a length of 16 mm is also available on request

Z-Line T-LineX-Line

The Healing-Flange is placed on the insert to stabilize the bandage on fresh skin perforation tissue after application of the insert This minimizes excessive tissue proliferation The Healing-Flange has its own magnet core and is made off tissue friendly Titanium

Healing Flange

X-Line T-Line

Insertion standard tools

X-Line

H0004X2

Connector to handpiece

H0004X4

H0004X1

Connector to ratchet

Z-Line amp T-Line

H0004T2

Connector to handpiece

Connector to ratchet

H0004T4

H0004T1

Connector to I-Ratchet-2Connector to I-Ratchet-2

14

APEXDIAMETER

PLATFORM DIAMETER

PLATFORM DIAMETER (flange)

MAJOR DIAMETER

COLLAR HEIGHT

THREADPITCH

APEXDIAMETER

THREADPITCH

COLLAR HEIGHT

HEXHEIGHT

HEXWIDTH

ProstheticColourCode

PLATFORM DIAMETER

(flange)

MAJOR DIAMETER

IE

IET

IETi

375

45

45

480

407

407

270

270

270

040 280

245

245

Cylindricalor Tapered

CT 63 4

radic

radic

radic

radic radic06

05

05

025

025

07

07

07

C

T

T

Oslash375mm

Oslash45mm

Oslash45mm

RANGE IMPLANT LENGTHS

IMPLANT DIMENSIONS AND INFORMATION

The following symbols are used on our packaging labels and they indicate the following

1

3

4

6

7

6

AMERICAS ASIA Southern Implants North America Inc 225 Chimney Corner Lane Suite 3011 Jupiter FL 33458 United States of America

Southern Implants UK Ltd Building 3 Chiswick Park566 Chiswick High Road London W4 5YA United KingdomEC REP

1 Albert Rd IRENE 0062 South AfricaSouthern Implants (Pty) Ltd

22797

STERILIZE2

only

yyyy-mm

LOTLOT

5

IET4

IET4

IET4

Doc 0000-0 Rev 0

IET4

REF

REF

REF

REF

(01) 00000000000000(17) Date packed(10) Expiry Date

Ext Hex Tapered Implant Ultra-Short Oslash45 x 4mm

Oslash45 x 4mm Oslash45 x 4mm

Manufacturer1

2

3

4

7

55

6

STERILE R

Implant details and size

Implant image

Sterilization using Irradiation

Caution

CE mark and notified body number

Expiry date

Prescription device

ii

STERILE R

22

STERILIZE2

STERILIZE2 Do not Resterilize

Consult instruction for use

Do not reuse

Sterile unless package is opened or damaged

CAUTION FEDERAL LAW RESTRICTS THE DEVICE TO SALE BY OR ON THE ORDER OF A LICENCED HEALTH CARE PROVIDER

Patient sticker for documentation purposes(to be used by health care provider on patient file)

2D Bar codingContains the GTIN Expiry Date and LOT Number

EXPLANATION OF SYMBOLS

15

copy2019 Southern Implants (Pty) Ltd All rights reserved Co-Axis Southern Implantsand Subcrestal Angle Correctionare registered trademarks and Body-Shift INVERTA and PROVATA are trademarks of Southern Implants (Pty) Ltd Not all implants are available in all markets

CAT-2010-08 (C1073)

For more information please contact your Southern Implants Representative or visit southernimplantscom

Subsidiaries

AustraliaSouthern Implants AustraliaT +61-2-8076-9337E infosouthernimplantscomau

United KingdomSouthern Implants UKT +44-20-8899-6845 6 7E infosouthernimplantscouk

USA and CanadaSouthern Implants North America IncT +1-561-472-0990E customercaresouthernimplantscom

South Africa ndash Headquarters 1 Albert Road Irene RSAT +27-12-667-1046 | E infosouthernimplantscom

Southern Implants Products are distributed world-wide please visit southernimplantscom for a list of Distributors

  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • Page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Page 15
  • Page 16

13

STECO TITANMAGNETICS

Oslash480 Oslash580

Height

265 mmHeight

315 mmProstheses magnet

Insert Attachment

30 N (300 g)Withdrawal force16 N (163 g)

X-Line Z-Line

reg The slightly curved surface of the spherical StecoTitanmagnetics X-Line and the Z-Line facilitates self centering and has the lowest lateral force introduction into the implant X-Line and Z-Line are therefore particularly suitable for short implants Due to the absence of lateral steering they are also indicated for highly divergent implants

Spherical magnets

T-Line

reg The StecoTitanmagnetics T-Line was developed exclusively for extraoral use The telescopic bearing of 25 mm gives the facial prosthesis secure fixation on the tissue The design allows a certain amount of rotation and axial movement without losing the withdrawal force

Telescopic magnets

Oslash580

Distance height

Distance height

Distance height

Height

57 mm

14 N (143 g)

Prosthesis magnet

Withdrawal force

Insert Attachment

Prosthetic Components

In X-Line and Z-Line there are prostheses magnets for acrylic and with additional retention for silicone For more lateral support there are prostheses magnets with extended collars available

For silicone

with collar and retention ring

with retention ring with rotation protection with collar

For acrylicFor silicone For acrylic

Universalwith retention ring

In the T-Line there are also prostheses magnets for acrylic and with additional retention for silicone

Accessories

To make a new prostheses each product line has its own compatible impression copings and laboratory analogues

Impression Copings- magnetic impression without screws- lock magnetically to the insert- the external geometry ensures the impression material is securely fi xed

Z-Line T-LineX-Line

Laboratory Analogues- for making models quickly and hygienically- the original implant does not have to be used on the insertion point of an analogue

- there is no need for time-consuming cleaning- a length of 16 mm is also available on request

Z-Line T-LineX-Line

The Healing-Flange is placed on the insert to stabilize the bandage on fresh skin perforation tissue after application of the insert This minimizes excessive tissue proliferation The Healing-Flange has its own magnet core and is made off tissue friendly Titanium

Healing Flange

X-Line T-Line

Insertion standard tools

X-Line

H0004X2

Connector to handpiece

H0004X4

H0004X1

Connector to ratchet

Z-Line amp T-Line

H0004T2

Connector to handpiece

Connector to ratchet

H0004T4

H0004T1

Connector to I-Ratchet-2Connector to I-Ratchet-2

14

APEXDIAMETER

PLATFORM DIAMETER

PLATFORM DIAMETER (flange)

MAJOR DIAMETER

COLLAR HEIGHT

THREADPITCH

APEXDIAMETER

THREADPITCH

COLLAR HEIGHT

HEXHEIGHT

HEXWIDTH

ProstheticColourCode

PLATFORM DIAMETER

(flange)

MAJOR DIAMETER

IE

IET

IETi

375

45

45

480

407

407

270

270

270

040 280

245

245

Cylindricalor Tapered

CT 63 4

radic

radic

radic

radic radic06

05

05

025

025

07

07

07

C

T

T

Oslash375mm

Oslash45mm

Oslash45mm

RANGE IMPLANT LENGTHS

IMPLANT DIMENSIONS AND INFORMATION

The following symbols are used on our packaging labels and they indicate the following

1

3

4

6

7

6

AMERICAS ASIA Southern Implants North America Inc 225 Chimney Corner Lane Suite 3011 Jupiter FL 33458 United States of America

Southern Implants UK Ltd Building 3 Chiswick Park566 Chiswick High Road London W4 5YA United KingdomEC REP

1 Albert Rd IRENE 0062 South AfricaSouthern Implants (Pty) Ltd

22797

STERILIZE2

only

yyyy-mm

LOTLOT

5

IET4

IET4

IET4

Doc 0000-0 Rev 0

IET4

REF

REF

REF

REF

(01) 00000000000000(17) Date packed(10) Expiry Date

Ext Hex Tapered Implant Ultra-Short Oslash45 x 4mm

Oslash45 x 4mm Oslash45 x 4mm

Manufacturer1

2

3

4

7

55

6

STERILE R

Implant details and size

Implant image

Sterilization using Irradiation

Caution

CE mark and notified body number

Expiry date

Prescription device

ii

STERILE R

22

STERILIZE2

STERILIZE2 Do not Resterilize

Consult instruction for use

Do not reuse

Sterile unless package is opened or damaged

CAUTION FEDERAL LAW RESTRICTS THE DEVICE TO SALE BY OR ON THE ORDER OF A LICENCED HEALTH CARE PROVIDER

Patient sticker for documentation purposes(to be used by health care provider on patient file)

2D Bar codingContains the GTIN Expiry Date and LOT Number

EXPLANATION OF SYMBOLS

15

copy2019 Southern Implants (Pty) Ltd All rights reserved Co-Axis Southern Implantsand Subcrestal Angle Correctionare registered trademarks and Body-Shift INVERTA and PROVATA are trademarks of Southern Implants (Pty) Ltd Not all implants are available in all markets

CAT-2010-08 (C1073)

For more information please contact your Southern Implants Representative or visit southernimplantscom

Subsidiaries

AustraliaSouthern Implants AustraliaT +61-2-8076-9337E infosouthernimplantscomau

United KingdomSouthern Implants UKT +44-20-8899-6845 6 7E infosouthernimplantscouk

USA and CanadaSouthern Implants North America IncT +1-561-472-0990E customercaresouthernimplantscom

South Africa ndash Headquarters 1 Albert Road Irene RSAT +27-12-667-1046 | E infosouthernimplantscom

Southern Implants Products are distributed world-wide please visit southernimplantscom for a list of Distributors

  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • Page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Page 15
  • Page 16

14

APEXDIAMETER

PLATFORM DIAMETER

PLATFORM DIAMETER (flange)

MAJOR DIAMETER

COLLAR HEIGHT

THREADPITCH

APEXDIAMETER

THREADPITCH

COLLAR HEIGHT

HEXHEIGHT

HEXWIDTH

ProstheticColourCode

PLATFORM DIAMETER

(flange)

MAJOR DIAMETER

IE

IET

IETi

375

45

45

480

407

407

270

270

270

040 280

245

245

Cylindricalor Tapered

CT 63 4

radic

radic

radic

radic radic06

05

05

025

025

07

07

07

C

T

T

Oslash375mm

Oslash45mm

Oslash45mm

RANGE IMPLANT LENGTHS

IMPLANT DIMENSIONS AND INFORMATION

The following symbols are used on our packaging labels and they indicate the following

1

3

4

6

7

6

AMERICAS ASIA Southern Implants North America Inc 225 Chimney Corner Lane Suite 3011 Jupiter FL 33458 United States of America

Southern Implants UK Ltd Building 3 Chiswick Park566 Chiswick High Road London W4 5YA United KingdomEC REP

1 Albert Rd IRENE 0062 South AfricaSouthern Implants (Pty) Ltd

22797

STERILIZE2

only

yyyy-mm

LOTLOT

5

IET4

IET4

IET4

Doc 0000-0 Rev 0

IET4

REF

REF

REF

REF

(01) 00000000000000(17) Date packed(10) Expiry Date

Ext Hex Tapered Implant Ultra-Short Oslash45 x 4mm

Oslash45 x 4mm Oslash45 x 4mm

Manufacturer1

2

3

4

7

55

6

STERILE R

Implant details and size

Implant image

Sterilization using Irradiation

Caution

CE mark and notified body number

Expiry date

Prescription device

ii

STERILE R

22

STERILIZE2

STERILIZE2 Do not Resterilize

Consult instruction for use

Do not reuse

Sterile unless package is opened or damaged

CAUTION FEDERAL LAW RESTRICTS THE DEVICE TO SALE BY OR ON THE ORDER OF A LICENCED HEALTH CARE PROVIDER

Patient sticker for documentation purposes(to be used by health care provider on patient file)

2D Bar codingContains the GTIN Expiry Date and LOT Number

EXPLANATION OF SYMBOLS

15

copy2019 Southern Implants (Pty) Ltd All rights reserved Co-Axis Southern Implantsand Subcrestal Angle Correctionare registered trademarks and Body-Shift INVERTA and PROVATA are trademarks of Southern Implants (Pty) Ltd Not all implants are available in all markets

CAT-2010-08 (C1073)

For more information please contact your Southern Implants Representative or visit southernimplantscom

Subsidiaries

AustraliaSouthern Implants AustraliaT +61-2-8076-9337E infosouthernimplantscomau

United KingdomSouthern Implants UKT +44-20-8899-6845 6 7E infosouthernimplantscouk

USA and CanadaSouthern Implants North America IncT +1-561-472-0990E customercaresouthernimplantscom

South Africa ndash Headquarters 1 Albert Road Irene RSAT +27-12-667-1046 | E infosouthernimplantscom

Southern Implants Products are distributed world-wide please visit southernimplantscom for a list of Distributors

  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • Page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Page 15
  • Page 16

The following symbols are used on our packaging labels and they indicate the following

1

3

4

6

7

6

AMERICAS ASIA Southern Implants North America Inc 225 Chimney Corner Lane Suite 3011 Jupiter FL 33458 United States of America

Southern Implants UK Ltd Building 3 Chiswick Park566 Chiswick High Road London W4 5YA United KingdomEC REP

1 Albert Rd IRENE 0062 South AfricaSouthern Implants (Pty) Ltd

22797

STERILIZE2

only

yyyy-mm

LOTLOT

5

IET4

IET4

IET4

Doc 0000-0 Rev 0

IET4

REF

REF

REF

REF

(01) 00000000000000(17) Date packed(10) Expiry Date

Ext Hex Tapered Implant Ultra-Short Oslash45 x 4mm

Oslash45 x 4mm Oslash45 x 4mm

Manufacturer1

2

3

4

7

55

6

STERILE R

Implant details and size

Implant image

Sterilization using Irradiation

Caution

CE mark and notified body number

Expiry date

Prescription device

ii

STERILE R

22

STERILIZE2

STERILIZE2 Do not Resterilize

Consult instruction for use

Do not reuse

Sterile unless package is opened or damaged

CAUTION FEDERAL LAW RESTRICTS THE DEVICE TO SALE BY OR ON THE ORDER OF A LICENCED HEALTH CARE PROVIDER

Patient sticker for documentation purposes(to be used by health care provider on patient file)

2D Bar codingContains the GTIN Expiry Date and LOT Number

EXPLANATION OF SYMBOLS

15

copy2019 Southern Implants (Pty) Ltd All rights reserved Co-Axis Southern Implantsand Subcrestal Angle Correctionare registered trademarks and Body-Shift INVERTA and PROVATA are trademarks of Southern Implants (Pty) Ltd Not all implants are available in all markets

CAT-2010-08 (C1073)

For more information please contact your Southern Implants Representative or visit southernimplantscom

Subsidiaries

AustraliaSouthern Implants AustraliaT +61-2-8076-9337E infosouthernimplantscomau

United KingdomSouthern Implants UKT +44-20-8899-6845 6 7E infosouthernimplantscouk

USA and CanadaSouthern Implants North America IncT +1-561-472-0990E customercaresouthernimplantscom

South Africa ndash Headquarters 1 Albert Road Irene RSAT +27-12-667-1046 | E infosouthernimplantscom

Southern Implants Products are distributed world-wide please visit southernimplantscom for a list of Distributors

  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • Page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Page 15
  • Page 16

copy2019 Southern Implants (Pty) Ltd All rights reserved Co-Axis Southern Implantsand Subcrestal Angle Correctionare registered trademarks and Body-Shift INVERTA and PROVATA are trademarks of Southern Implants (Pty) Ltd Not all implants are available in all markets

CAT-2010-08 (C1073)

For more information please contact your Southern Implants Representative or visit southernimplantscom

Subsidiaries

AustraliaSouthern Implants AustraliaT +61-2-8076-9337E infosouthernimplantscomau

United KingdomSouthern Implants UKT +44-20-8899-6845 6 7E infosouthernimplantscouk

USA and CanadaSouthern Implants North America IncT +1-561-472-0990E customercaresouthernimplantscom

South Africa ndash Headquarters 1 Albert Road Irene RSAT +27-12-667-1046 | E infosouthernimplantscom

Southern Implants Products are distributed world-wide please visit southernimplantscom for a list of Distributors

  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • Page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Page 15
  • Page 16