CAST INTO FOOTINGS

2
Project: New Residence Client: Harley Truong Drawn: Harley Truong Address: 10 Anderson St Chifley Canberra Block: 1 Scale @ A3 1:100 Drawing No C02.7 Sec: 3 Date: 2.11.13 Revision: 12 Slab plan - House 1A Revision Date Checked Approved 12 2.11.13 HT HT 11 18.10.13 HT HT 10 1.8.13 HT HT 0 5 north 100 450 24570 450 2400 7530 50mm SETDOWN 400 800 8790 7590 50 50 50 50 20 150 120 FOR CONSTRUCTION 9mm PLYWOOD CLADDING TO GARAGE 3740 450 450 450 450 5520 5600 450 5600 450 5600 8240 450 1 FOOTINGS Scale: 1 : 100 2 SLAB Scale: 1 : 100 A SECTION Scale: 1 : 20 MIN 450mm WIDE x 450mm DEEP 20MPa STRIP FOOTING WITH 4-11 T-M TOP AND BOTTOM AND 300mm HIGH STEEL CLIPS AT 900mm CTRS 1800 2395 6000 120 400 LAP 2 IN 1 TERMITE BARRIER, DAMP PROOF MEMBRANE TYP MIN 200um DAMP PROOF MEMBRANE MIN 200um POLYTHENE TYP 18210 7350 DAMP PROOF MEMBRANE MIN 200um POLYTHENE 120mm 32MPa CONCRETE DRIVEWAY SL82 TOP AND BOTTOM B DRIVEWAY Scale: 1 : 20 120mm WITH 150mm EDGE THICKENING 32MPa SLAB SL82 TOP AND BOTTOM ON MIN 200um POLYTHENE. STEEL TROWEL FINISH 120 120 6180 350 900 TYP REFER PLUMBING PLAN C2.29 FOR LOCATION OF SLAB PENETRATIONS 100mm 32MPa SLAB SL82 TOP ON MIN 200um DPM STEEL TROWEL FINISH UNDISTURBED SOIL 'OZONE' SIP PANELS 15mm UNTREATED OSB 90mm PIR FOAM 15mm UNTREATED OSB TO BE INSTALLED TO MANUFACTURER SPECS WITH 3mm x 55mm RING SHAFT NAILS AT 150mm CNTRS TO TOP AND BOTTOM PLATES AND STUDS FFL HOUSE 20mm CORK FLOORING 70 A 2500 100mm 32MPa SLAB SL82 TOP ON MIN 200um DPM STEEL TROWEL FINISH * H3 TREATED SOLE PLATE * H3 TREATED BOTTOM PLATE * COAT BOTTOM 150mm OF OSB WITH BRUSH ON CHEMICAL PRESERVATIVE WALL CLADDING 19mm SCYON BATTEN 8mm SCYON MATRIX XPS FOAM MIN 220kPa COMPRESSIVE STRENGTH @ 10% DEFLECTION 3 x 50mm LAYERS (CERTIFICATION ON FIT-FOR-PURPOSE TO BCA REQUIRED BY SUPPLIER) 50 MIN 80mm EXPOSED SLAB EDGE FOR TERMITE INSPECTION AS PER AS3660.1 100 COMPACTED FILL 50mm WET AREA SLAB SETDOWN M10 GALV THREADED ROD CAST INTO FOOTINGS AT 900mm CTRS, 200mm DEEP MIN WALLS INSTALLED FIRST AND THEN USED AS FORMWORK FOR HOUSE AND GARAGE SLABS 150 MIN MIN 150 N12 PERIMETER BAR TYP N12 PERIMETER BAR WITH MIN 600mm LAPS TYP 2000 TYP 2000 TYP FFL GARAGE B SL82 TOP ALCOR ALUMINIUM SLIP JOINT 300um TYP 2 IN 1 TERMITE BARRIER, DAMP PROOF MEMBRANE MIN 200um TYP DAMP PROOF MEMBRANE MIN 200um POLYTHENE TYP MIN 450mm DEEP x 450mm WIDE 20MPa STRIP FOOTING WITH 4-11 T-M TOP AND BOTTOM AND 300mm HIGH STEEL CLIPS AT 900mm CTRS ALCOR ALUMINIUM SLIP JOINT 300um TYP 100 TYP 1750 200 x 160 x 12mm GALV BASE PLATES CAST INTO FOOTINGS WITH 4 X M12 THREADED RODS VAPOUR PERMEABLE MEMBRANE M10 GALV THREADED ROD CAST INTO FOOTINGS AT 900mm CTRS, 200mm DEEP MIN, 100mm PROTUDING ABOVE FOOTING 60 TYP

Transcript of CAST INTO FOOTINGS

Page 1: CAST INTO FOOTINGS

Project: New ResidenceClient: Harley TruongDrawn: Harley Truong

Address: 10 Anderson St Chifley Canberra

Block: 1

Scale @ A3 1:100

Drawing No C02.7

Sec: 3

Date: 2.11.13

Revision: 12

Slab plan - House 1A

Revision Date Checked Approved 12 2.11.13 HT HT11 18.10.13 HT HT10 1.8.13 HT HT

0 5

north

100

450

24570

450

2400 753050mm SETDOWN

400

800

8790

7590

50505050

20

150

120

FOR CONSTRUCTION9mm PLYWOOD CLADDINGTO GARAGE

3740

450

450

450

450 5520560045056004505600

8240

450

1FOOTINGSScale: 1 : 100

2SLABScale: 1 : 100

ASECTIONScale: 1 : 20

MIN 450mm WIDE x 450mm DEEP20MPa STRIP FOOTING WITH4-11 T-M TOP AND BOTTOMAND 300mm HIGH STEEL CLIPSAT 900mm CTRS

1800

2395

6000

120

400LAP

2 IN 1TERMITE BARRIER,DAMP PROOFMEMBRANE TYPMIN 200um

DAMP PROOF MEMBRANEMIN 200um POLYTHENE TYP

18210

7350

DAMP PROOF MEMBRANEMIN 200um POLYTHENE

120mm 32MPa CONCRETE DRIVEWAY SL82 TOP AND BOTTOM

BDRIVEWAYScale: 1 : 20

120mm WITH 150mmEDGE THICKENING32MPa SLABSL82 TOP AND BOTTOMON MIN 200umPOLYTHENE.STEEL TROWEL FINISH

120

120

6180

350

900 TYP

REFER PLUMBING PLAN C2.29FOR LOCATION OF SLAB PENETRATIONS

100mm 32MPa SLABSL82 TOP ON MIN 200umDPM

STEEL TROWEL FINISH

UNDISTURBED SOIL

'OZONE' SIP PANELS 15mm UNTREATED OSB 90mm PIR FOAM 15mm UNTREATED OSB

TO BE INSTALLED TOMANUFACTURER SPECSWITH 3mm x 55mm RINGSHAFT NAILS AT 150mm CNTRSTO TOP AND BOTTOM PLATES AND STUDS

FFL HOUSE

20mm CORK FLOORING

70

A

2500

100mm 32MPa SLABSL82 TOP ON MIN 200umDPM

STEEL TROWEL FINISH

* H3 TREATED SOLE PLATE* H3 TREATED BOTTOM PLATE* COAT BOTTOM 150mm OF OSBWITH BRUSH ONCHEMICAL PRESERVATIVE

WALL CLADDING 19mm SCYON BATTEN 8mm SCYON MATRIX

XPS FOAM MIN 220kPa COMPRESSIVE STRENGTH @ 10% DEFLECTION3 x 50mm LAYERS(CERTIFICATION ON FIT-FOR-PURPOSETO BCA REQUIRED BY SUPPLIER)

50

MIN 80mmEXPOSED SLABEDGE FOR TERMITEINSPECTION ASPER AS3660.1

100

COMPACTEDFILL

50mm WET AREASLAB SETDOWN

M10 GALV THREADEDROD CAST INTO FOOTINGSAT 900mm CTRS, 200mm DEEP MIN

WALLS INSTALLED FIRSTAND THEN USED AS FORMWORK FOR HOUSE AND GARAGE SLABS

150MIN

MIN 150

N12PERIMETERBAR TYP

N12 PERIMETER BARWITH MIN

600mm LAPS TYP

2000 TYP

2000 TYP

FFL GARAGE

B

SL82 TOPALCORALUMINIUMSLIP JOINT300um TYP

2 IN 1TERMITE BARRIER,DAMP PROOFMEMBRANEMIN 200um TYP

DAMP PROOF MEMBRANEMIN 200um POLYTHENE TYP

MIN 450mm DEEP x 450mm WIDE 20MPa STRIP FOOTING WITH4-11 T-M TOP AND BOTTOMAND 300mm HIGH STEEL CLIPSAT 900mm CTRS

ALCORALUMINIUMSLIP JOINT300um TYP

100TYP

1750

200 x 160 x 12mmGALV BASE PLATES CAST INTO FOOTINGSWITH 4 X M12 THREADEDRODS

VAPOUR PERMEABLEMEMBRANE

M10 GALV THREADEDROD CAST INTO FOOTINGSAT 900mm CTRS, 200mm DEEP MIN,100mm PROTUDING ABOVE FOOTING

60 TYP

Page 2: CAST INTO FOOTINGS

Project: New ResidenceClient: Harley TruongDrawn: Harley Truong

Address: 10 Anderson St Chifley Canberra

Block: 1

Scale @ A3 1:100

Drawing No C02.8

Sec: 3

Date: 2.11.13

Revision: 4

Slab plan - House 1B

Revision Date Checked Approved 4 2.11.13 HT HT3 18.10.13 HT HT2 1.8.13 HT HT

0 5

north

100

450

22170

450

2400753050mm SETDOWN

400

800

8790

7590

50505050

20

150

120

FOR CONSTRUCTION9mm PLYWOOD CLADDINGTO GARAGE

3740

450

450

450

4503120 5600 450 5600 450 5600

5840

450

1FOOTINGSScale: 1 : 100

2SLABScale: 1 : 100

ASECTIONScale: 1 : 20

MIN 450mm WIDE x 450mm DEEP20MPa STRIP FOOTING WITH4-11 T-M TOP AND BOTTOMAND 300mm HIGH STEEL CLIPSAT 900mm CTRS

2395

3600

120

400LAP

2 IN 1TERMITE BARRIER,DAMP PROOFMEMBRANE TYP

DAMP PROOF MEMBRANEMIN 200um POLYTHENE TYP

18210

7350

DAMP PROOF MEMBRANEMIN 200um POLYTHENE

120mm 32MPaCONCRETE DRIVEWAYSL82 TOP AND BOTTOM

BDRIVEWAYScale: 1 : 20

120mm WITH 150mmEDGE THICKENING32MPa SLABSL82 TOPAND BOTTOMON MIN 200umPOLYTHENE.STEEL TROWEL FINISH

120

120

100mm 32MPa SLABSL82 TOP ON MIN 200um DPM

STEEL TROWEL FINISH

UNDISTURBED SOIL

'OZONE' SIP PANELS 15mm UNTREATED OSB 90mm PIR FOAM 15mm UNTREATED OSB

TO BE INSTALLED TOMANUFACTURER SPECSWITH 3mm x 55mm RINGSHAFT NAILS AT 150mm CNTRSTO TOP AND BOTTOM PLATESAND STUDS

MIN 450mm WIDE x 450mm DEEP 20MPa STRIP FOOTING WITH4-11 T-M TOP AND BOTTOMAND 300mm HIGH STEEL CLIPSAT 900mm CTRS

FFL HOUSE

20mm CORK FLOORING

70

A

2500

100mm 32MPa SLABSL82 TOP ON MIN 200umDPM

STEEL TROWEL FINISH

* H3 TREATED SOLE PLATE* H3 TREATED BOTTOM PLATE* BRUSH BOTTOM 150mm OF OSBWITH CHEMICAL PRESERVATIVE

SLOPE GROUNDAWAY FROMFOOTINGS

WALL CLADDING 19mm SCYON BATTEN 8mm SCYON MATRIX

XPS FOAM MIN 220kPa COMPRESSIVE STRENGTH @ 10% DEFLECTION3 x 50mm LAYERS(CERTIFICATION ON FIT-FOR-PURPOSETO BCA REQUIRED BY SUPPLIER)

50

MIN 80mmEXPOSED SLABEDGE FOR TERMITEINSPECTION ASPER AS3660.1

100

COMPACTEDFILL

50mm WET AREASLAB SETDOWN

M10 GALV THREADEDROD CAST INTO FOOTINGSAT 900mm CTRS, 200mm DEEP MIN

WALLS INSTALLED FIRSTAND THEN USED AS FORMWORK FOR HOUSE AND GARAGE SLABS

150MIN

MIN 150

N12PERIMETERBAR TYP

N12 PERIMETER BARWITH MIN

600mm LAPS TYP

2000 TYP

2000 TYP

FFL GARAGE

B

SL82 TOPALCORALUMINIUMSLIP JOINT300um TYP

2 IN 1TERMITE BARRIER,DAMP PROOFMEMBRANE TYP200um

DAMP PROOF MEMBRANEMIN 200um POLYTHENE TYP

ALCORALUMINIUMSLIP JOINT300um TYP

100TYP

1800

350

900 TYP

1750

200 x 160 x 12mmGALV BASE PLATES CAST INTO FOOTINGSWITH 4 X M12 THREADEDRODS

60 TYP

M10 GALV THREADEDROD CAST INTO FOOTINGSAT 900mm CTRS, 200mm DEEP MIN,100mm PROTUDING ABOVE FOOTING

REFER PLUMBING PLAN C2.30FOR LOCATION OF SLAB PENETRATIONS

VAPOUR PERMEABLEMEMBRANE

3780