Case Study : Marco Pierre White Restuarant Location ... · Case Study : Marco Pierre White...
Transcript of Case Study : Marco Pierre White Restuarant Location ... · Case Study : Marco Pierre White...
![Page 1: Case Study : Marco Pierre White Restuarant Location ... · Case Study : Marco Pierre White Restuarant Location : Dublin 4, Ireland JouleThermCeP|24V Electric Paint Heating System](https://reader031.fdocuments.net/reader031/viewer/2022022111/5c5cfe3a09d3f230418c34f8/html5/thumbnails/1.jpg)
![Page 2: Case Study : Marco Pierre White Restuarant Location ... · Case Study : Marco Pierre White Restuarant Location : Dublin 4, Ireland JouleThermCeP|24V Electric Paint Heating System](https://reader031.fdocuments.net/reader031/viewer/2022022111/5c5cfe3a09d3f230418c34f8/html5/thumbnails/2.jpg)
Case Study : Marco Pierre White Restuarant Location : Dublin 4, Ireland
JouleTherm CeP | 24V Electric Paint Heating System
It is very hard to believe that we are heating our restuarant for less than €0.80 cent / hour. If we sell one cup of coffee an hour we have covered the heating bill. Seriously impressed with the guys work here
Tony Keogh CEO , Marco Pierre White Dublin
![Page 3: Case Study : Marco Pierre White Restuarant Location ... · Case Study : Marco Pierre White Restuarant Location : Dublin 4, Ireland JouleThermCeP|24V Electric Paint Heating System](https://reader031.fdocuments.net/reader031/viewer/2022022111/5c5cfe3a09d3f230418c34f8/html5/thumbnails/3.jpg)
Technical Guideline DocumentJouleTherm CeP | 24V Conductive Wall Paint
![Page 4: Case Study : Marco Pierre White Restuarant Location ... · Case Study : Marco Pierre White Restuarant Location : Dublin 4, Ireland JouleThermCeP|24V Electric Paint Heating System](https://reader031.fdocuments.net/reader031/viewer/2022022111/5c5cfe3a09d3f230418c34f8/html5/thumbnails/4.jpg)
Technical Guideline DocumentJouleTherm CeP | 24V Conductive Wall Paint
![Page 5: Case Study : Marco Pierre White Restuarant Location ... · Case Study : Marco Pierre White Restuarant Location : Dublin 4, Ireland JouleThermCeP|24V Electric Paint Heating System](https://reader031.fdocuments.net/reader031/viewer/2022022111/5c5cfe3a09d3f230418c34f8/html5/thumbnails/5.jpg)
STRICTLY CONFIDENTIAL5
System Components
Base Primer
• Chemical protection
• Thermal isolation
Copper Electrodes
• 24V Connection / Binding
• Self-adhesive
JouleTherm CeP
• Nano-carbon based wall paint
• Nano particles form electrical conductivity
Decorative Wall Paint
• Standard wall paint as over-paint
• Totally invisible using electrode
Power Connection
• Crimped connection point in recessed PVC box
• Box lid for maximum safety and inspection point
Power Supply
• Low Voltage 24V AC
• Localized location or central location
Electrode
Connection
![Page 6: Case Study : Marco Pierre White Restuarant Location ... · Case Study : Marco Pierre White Restuarant Location : Dublin 4, Ireland JouleThermCeP|24V Electric Paint Heating System](https://reader031.fdocuments.net/reader031/viewer/2022022111/5c5cfe3a09d3f230418c34f8/html5/thumbnails/6.jpg)
Multi – Zone Heating | Large Scale Applications
STRICTLY CONFIDENTIAL6
SSR
Relay
230V AC
Digital PWM Control Signal
24VAC
Torodial
Transformator
SSR
Relay
SSR
Relay24VAC
Torodial
Transformator
24VAC
Torodial
Transformator
+
-+
-+
-
e.g. 3600W
e.g. 2900W
e.g. 1500W
Base & digital thermal control if required
Wired or wireless thermostats available
Custom made to order transformers made in the UK
230V AC
Wall
Sensor
Single Phase
230V AC
40A
Te
mp
Se
nso
r
![Page 7: Case Study : Marco Pierre White Restuarant Location ... · Case Study : Marco Pierre White Restuarant Location : Dublin 4, Ireland JouleThermCeP|24V Electric Paint Heating System](https://reader031.fdocuments.net/reader031/viewer/2022022111/5c5cfe3a09d3f230418c34f8/html5/thumbnails/7.jpg)
Technical Guideline DocumentJouleTherm CeP | 24V Conductive Wall Paint
![Page 8: Case Study : Marco Pierre White Restuarant Location ... · Case Study : Marco Pierre White Restuarant Location : Dublin 4, Ireland JouleThermCeP|24V Electric Paint Heating System](https://reader031.fdocuments.net/reader031/viewer/2022022111/5c5cfe3a09d3f230418c34f8/html5/thumbnails/8.jpg)
Technical Guideline DocumentJouleTherm CeP | 24V Conductive Wall Paint
![Page 9: Case Study : Marco Pierre White Restuarant Location ... · Case Study : Marco Pierre White Restuarant Location : Dublin 4, Ireland JouleThermCeP|24V Electric Paint Heating System](https://reader031.fdocuments.net/reader031/viewer/2022022111/5c5cfe3a09d3f230418c34f8/html5/thumbnails/9.jpg)
Technical Guideline DocumentJouleTherm CeP | 24V Conductive Wall Paint
![Page 10: Case Study : Marco Pierre White Restuarant Location ... · Case Study : Marco Pierre White Restuarant Location : Dublin 4, Ireland JouleThermCeP|24V Electric Paint Heating System](https://reader031.fdocuments.net/reader031/viewer/2022022111/5c5cfe3a09d3f230418c34f8/html5/thumbnails/10.jpg)
Technical Guideline DocumentJouleTherm CeP | 24V Conductive Wall Paint
![Page 11: Case Study : Marco Pierre White Restuarant Location ... · Case Study : Marco Pierre White Restuarant Location : Dublin 4, Ireland JouleThermCeP|24V Electric Paint Heating System](https://reader031.fdocuments.net/reader031/viewer/2022022111/5c5cfe3a09d3f230418c34f8/html5/thumbnails/11.jpg)
08
.09
.20
17
Strictly Confidential & Non Binding 11
Connect heating circuits to 24V transformer HCU 3Z1
![Page 12: Case Study : Marco Pierre White Restuarant Location ... · Case Study : Marco Pierre White Restuarant Location : Dublin 4, Ireland JouleThermCeP|24V Electric Paint Heating System](https://reader031.fdocuments.net/reader031/viewer/2022022111/5c5cfe3a09d3f230418c34f8/html5/thumbnails/12.jpg)
1500W 22V – 24V Heater Control Unit Specification
• Heater Control Unit 3Z1Supplier: Matt:e LtdBS 7671 Amendment 3 compliant metal enclosureIncoming supply via 2 pole 6A Type B MCBToriodal transformer - Double insulated to SELV requirementsPrimary winding 230v 5.2A at full loadMatt:e voltage mapped inrush limiting PCB for primary winding supply3 x 22V SELV secondary windings = 1500VA (3 Zone)3 x 20A Type B single pole MCB with switched neutralControlled via single channel wireless thermostat and receiver
![Page 13: Case Study : Marco Pierre White Restuarant Location ... · Case Study : Marco Pierre White Restuarant Location : Dublin 4, Ireland JouleThermCeP|24V Electric Paint Heating System](https://reader031.fdocuments.net/reader031/viewer/2022022111/5c5cfe3a09d3f230418c34f8/html5/thumbnails/13.jpg)
Technical Guideline DocumentJouleTherm CeP | 24V Conductive Wall Paint
![Page 14: Case Study : Marco Pierre White Restuarant Location ... · Case Study : Marco Pierre White Restuarant Location : Dublin 4, Ireland JouleThermCeP|24V Electric Paint Heating System](https://reader031.fdocuments.net/reader031/viewer/2022022111/5c5cfe3a09d3f230418c34f8/html5/thumbnails/14.jpg)
Technical Guideline DocumentJouleTherm CeP | 24V Conductive Wall Paint
![Page 15: Case Study : Marco Pierre White Restuarant Location ... · Case Study : Marco Pierre White Restuarant Location : Dublin 4, Ireland JouleThermCeP|24V Electric Paint Heating System](https://reader031.fdocuments.net/reader031/viewer/2022022111/5c5cfe3a09d3f230418c34f8/html5/thumbnails/15.jpg)
Restaurant back to original condition with JouleTherm CeP working
![Page 16: Case Study : Marco Pierre White Restuarant Location ... · Case Study : Marco Pierre White Restuarant Location : Dublin 4, Ireland JouleThermCeP|24V Electric Paint Heating System](https://reader031.fdocuments.net/reader031/viewer/2022022111/5c5cfe3a09d3f230418c34f8/html5/thumbnails/16.jpg)
Summary
• 208m2 of space – 4.8kw of CeP installed
• Max temperature achieved 25°C
• Target temperature maintained 21°C
• Impact on building structure – Zero
• Impact on electrical infrastructure – Zero
• Impact on business hours – Zero
• Capital cost savings against repair to existing heating system €28,000
• Estimated ROI – 7 months.
![Page 17: Case Study : Marco Pierre White Restuarant Location ... · Case Study : Marco Pierre White Restuarant Location : Dublin 4, Ireland JouleThermCeP|24V Electric Paint Heating System](https://reader031.fdocuments.net/reader031/viewer/2022022111/5c5cfe3a09d3f230418c34f8/html5/thumbnails/17.jpg)
ROI 6.8 Months
• Project capital cost to client €6,000 ex Vat
• Previous system average monthly bills €1,024.80 Ex Vat (6405 kWh / month @ 0.16kWh)
• New monthly energy bills €126.88 (Average 793 KWh / 8 months @ 0.16kWh)
• Savings / Month €897.92
• Savings on maintenance costs to old HVAC equipment €650 without consumables. (Not included in ROI)
![Page 18: Case Study : Marco Pierre White Restuarant Location ... · Case Study : Marco Pierre White Restuarant Location : Dublin 4, Ireland JouleThermCeP|24V Electric Paint Heating System](https://reader031.fdocuments.net/reader031/viewer/2022022111/5c5cfe3a09d3f230418c34f8/html5/thumbnails/18.jpg)
Live Data :November 29th – Aug 30th Readings / kWh tariff €0.1615 / kWhDec 2016 – 978kWh Apr 2017 – 459kWh Aug 2017 – 3kWhJan 2017 - 1180kWh May 2017 – 1136kWhFeb 2017 – 913kWh Jun 2017 - 198kWhMar 2017 – 1415kWh Jul 2017 - 31kWh
![Page 19: Case Study : Marco Pierre White Restuarant Location ... · Case Study : Marco Pierre White Restuarant Location : Dublin 4, Ireland JouleThermCeP|24V Electric Paint Heating System](https://reader031.fdocuments.net/reader031/viewer/2022022111/5c5cfe3a09d3f230418c34f8/html5/thumbnails/19.jpg)
STRICTLY CONFIDENTIAL 19
How to Contact Us:
UK & Ireland Sales Office
Ecovolt Limited142A Slaney CloseGlasnevin Industrial EstateDublin 11Ireland