CAP437 Chapter 6 Paragraph 4.6
States
“Calibration of Meteorological
Equipment Sensors:
Calibration of meteorological equip-
ment sensors used to provide the
data listed in paragraph 4.2 should
be periodically calibrated in accor-
dance with the manufacturers’ rec-
ommendations in order to demon-
strate continuing adequacy for pur-
pose.”
Chapter 6 Paragraph 4.2 Note 2
States
“Contingency meteorological ob-
serving equipment providing man-
ual
measurements of air and dew point
temperatures, wind speed and di-
rection and pressure is recom-
mended to be provided in case of
the failure or unavailability of the
automated sensors.”
CAP437 Compliant
Hand-Held Sensors
In May 2012 CAP437 was updated to include the CAA’s recommendation to include In May 2012 CAP437 was updated to include the CAA’s recommendation to include
manual sensors to be used on offshore platforms as a contingency in case of the failure manual sensors to be used on offshore platforms as a contingency in case of the failure
or unavailability of the automated sensors. The meteorological observations stated are or unavailability of the automated sensors. The meteorological observations stated are
air and dew point temperatures, wind speed and direction and pressure. Muir Matheson air and dew point temperatures, wind speed and direction and pressure. Muir Matheson
can provide a set of CAP437 compliant hand held sensors which cover the entire mete-can provide a set of CAP437 compliant hand held sensors which cover the entire mete-
orological requirements as stipulated aboveorological requirements as stipulated above. .
![Page 2: CAP437 Hand-Held.pdf](https://reader035.fdocuments.net/reader035/viewer/2022072107/563dbb12550346aa9aaa0237/html5/thumbnails/2.jpg)
Muir Matheson LtdMuir Matheson LtdMuir Matheson LtdMuir Matheson Ltd Aberlan House, Woodburn Road, Blackburn Industrial Estate,
Aberdeen AB21 0RX
UNITED KINGDOM T: +44 (0) 1224 791222 F: +44 (0) 1224 791555
IM159
Hand-Held Anemometer
Manufactured to a British Meteorological Office specification, this ro-Manufactured to a British Meteorological Office specification, this ro-
bust instrument is made from nonbust instrument is made from non--ferrous metal and calibrated in a ferrous metal and calibrated in a
wind tunnel for maximum accuracy.wind tunnel for maximum accuracy.
It indicates instantaneous wind speed on an analogue scale, which can It indicates instantaneous wind speed on an analogue scale, which can
be calibrated in knots, metres per second or miles per hour. be calibrated in knots, metres per second or miles per hour.
0 — 60 knots
0 — 60 mph
0 — 30 m/s
± 0.5 knot below 30 knots
± 1 knot above 31 knots
2 knots
2 knots
35 mm
210 mm (H) X 76mm (D)
450g
Range
Accuracy
Resolution
Start Threshold
Cup Diameter
Dimensions
Weight
![Page 3: CAP437 Hand-Held.pdf](https://reader035.fdocuments.net/reader035/viewer/2022072107/563dbb12550346aa9aaa0237/html5/thumbnails/3.jpg)
Muir Matheson LtdMuir Matheson LtdMuir Matheson LtdMuir Matheson Ltd Aberlan House, Woodburn Road, Blackburn Industrial Estate,
Aberdeen AB21 0RX
UNITED KINGDOM T: +44 (0) 1224 791222 F: +44 (0) 1224 791555
DPI740
Hand-Held Pressure Sensor
The DPI 740 is a portable battery powered precision barometer, provid-The DPI 740 is a portable battery powered precision barometer, provid-
ing outstanding capabilities in a handing outstanding capabilities in a hand--held package. This instrument held package. This instrument
can confidently be used in both laboratory and field applications as a can confidently be used in both laboratory and field applications as a
firstfirst--class barometric reference device, with the recommended recali-class barometric reference device, with the recommended recali-
bration period being one year. bration period being one year.
750 to 1150 mbar
±0.02%
Better than 100 ppm per annum.
0.01 mbar
190 mm x 90 mm x 36 mm
0.5kg
Range
Accuracy
Stability
Resolution
Dimensions
Weight
![Page 4: CAP437 Hand-Held.pdf](https://reader035.fdocuments.net/reader035/viewer/2022072107/563dbb12550346aa9aaa0237/html5/thumbnails/4.jpg)
Muir Matheson LtdMuir Matheson LtdMuir Matheson LtdMuir Matheson Ltd Aberlan House, Woodburn Road, Blackburn Industrial Estate,
Aberdeen AB21 0RX
UNITED KINGDOM T: +44 (0) 1224 791222 F: +44 (0) 1224 791555
HM40
Hand-Held Temperature &
Humidity Sensor
The HM40 is a compact and portable humidity meter at hand eve-The HM40 is a compact and portable humidity meter at hand eve-
rywhere you go. It is an ideal spotrywhere you go. It is an ideal spot--checking tool that is easy to checking tool that is easy to
use and provides reliable measurement. It can be used for a wide use and provides reliable measurement. It can be used for a wide
range of various portable measurement applications. According range of various portable measurement applications. According
to a user's needs, the meter is available in two models: standard to a user's needs, the meter is available in two models: standard
and with a remote probe.and with a remote probe.
0 — 100% RH -10 — +60°C
±1.5 %RH (±2.5 %RH between 90-100%)
±0.2 °C (0 — 40± °C) ±0.4 °C (-10 — 0°C & 40 — 60°C)
Humidity — 0.1%
Temperature 0.1°C
330g
Range
Accuracy
Resolution
Weight