Campaign integrated dust and erosion – EAST
-
Upload
autumn-tate -
Category
Documents
-
view
24 -
download
1
description
Transcript of Campaign integrated dust and erosion – EAST
![Page 1: Campaign integrated dust and erosion – EAST](https://reader030.fdocuments.net/reader030/viewer/2022032805/56813297550346895d992de4/html5/thumbnails/1.jpg)
Campaign integrated dust and erosion – EAST
J.S Hu, J.G Li and EAST team
Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui 230031, China
ASIPP
Sept. 15-18, 11th ITPA-SOL/DIV meeting, Nagasaki, Japan
EASTEAST
![Page 2: Campaign integrated dust and erosion – EAST](https://reader030.fdocuments.net/reader030/viewer/2022032805/56813297550346895d992de4/html5/thumbnails/2.jpg)
Outline
• Introduction
• Erosions/Depositions
• Dust
• summary
ASIPP
EASTEAST
![Page 3: Campaign integrated dust and erosion – EAST](https://reader030.fdocuments.net/reader030/viewer/2022032805/56813297550346895d992de4/html5/thumbnails/3.jpg)
Plasma operation in 2008 campaign• New carbon Plasma facing components• Shots number:#5132-9382, total 4250 shots;• Configurations: Limiter & Divertor with single/Double
null;• Main parameters of plasma:
– Bt~8.0KA;– Max. LHCD power: 800kW;– max. ICRF power: 260kW;– Max. Plasma current: 600kA;– Normal Plasma density: 1~4x1019/cm3.– Long plasmas
• ~20S, 250kA, ne~0.8x1019/cm3, 400kW(LHCD)• ~10S, 400kA, ne~1.5x1019/cm3, 400kW(LHCD)
ASIPP
EASTEAST
![Page 4: Campaign integrated dust and erosion – EAST](https://reader030.fdocuments.net/reader030/viewer/2022032805/56813297550346895d992de4/html5/thumbnails/4.jpg)
Main PSI issues for near futureProviding Useful Information for ITER
• Full C PFC (-2010) 2 MW/m2
W/Cu diverter(-2014), 10MW/m2
Full W PFC (-2016)
• RF wall conditioning techniques in divertor devices (cleaning, isotopic control, boronization).
• Develop Tritium removal techniques that could be applicable to ITER.
• Steady-state erosion, redeposition and dust formation.
• In-situ control of T-codeposition and inventory by surface temperature control.
EAST ASIPP
![Page 5: Campaign integrated dust and erosion – EAST](https://reader030.fdocuments.net/reader030/viewer/2022032805/56813297550346895d992de4/html5/thumbnails/5.jpg)
Dust during plasma discharges ASIPP
EASTEAST
#5674#6599
#7097
•In many shots, dusts were observed by CCD camera due to unfavorable position control.
![Page 6: Campaign integrated dust and erosion – EAST](https://reader030.fdocuments.net/reader030/viewer/2022032805/56813297550346895d992de4/html5/thumbnails/6.jpg)
Erosion/Deposits on walls
ASIPP
EASTEASTer
osi
on
on
so
me
tile
s
dep
osi
tio
n o
n s
om
e ti
les
![Page 7: Campaign integrated dust and erosion – EAST](https://reader030.fdocuments.net/reader030/viewer/2022032805/56813297550346895d992de4/html5/thumbnails/7.jpg)
ASIPP
EASTEAST
Dust location
• SOL zones at low field side • Both side of movable limiters• Near GDC anodes• On/near ICRF antenna for wall
conditioning• On/near coils box for fast control• ……
• Window tubes • In the gaps
![Page 8: Campaign integrated dust and erosion – EAST](https://reader030.fdocuments.net/reader030/viewer/2022032805/56813297550346895d992de4/html5/thumbnails/8.jpg)
Dust on/near ICRF antenna
ASIPP
EASTEAST
![Page 9: Campaign integrated dust and erosion – EAST](https://reader030.fdocuments.net/reader030/viewer/2022032805/56813297550346895d992de4/html5/thumbnails/9.jpg)
Dust on both sides of movable limiters ASIPP
EASTEAST
![Page 10: Campaign integrated dust and erosion – EAST](https://reader030.fdocuments.net/reader030/viewer/2022032805/56813297550346895d992de4/html5/thumbnails/10.jpg)
Dust near GDC anodes
ASIPP
EASTEAST
Dust
![Page 11: Campaign integrated dust and erosion – EAST](https://reader030.fdocuments.net/reader030/viewer/2022032805/56813297550346895d992de4/html5/thumbnails/11.jpg)
Dust on/near coil box ASIPP
EASTEAST
![Page 12: Campaign integrated dust and erosion – EAST](https://reader030.fdocuments.net/reader030/viewer/2022032805/56813297550346895d992de4/html5/thumbnails/12.jpg)
Dust integration and summary
ASIPP
EASTEAST
•Erosion seemed on the wall at high field side and movable limiters due to the lose of position control.•Most dust in tile gaps, SOL zones at low field sides, windows tubes…•Total collected dust was 4.05g.•~1mg/shot.