Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

110
Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0

Transcript of Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Page 1: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Calorimeter Data Monitoring News

Benoit Viaud

(LAL-in2p3)

B. Viaud, Calo Mtg Aug. 31st 2011 0

Page 2: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Overview

• Reminder: too many alarms make the monitoring inefficient;

• A survey of the Monitors' behavior over 2011;

• A few proposed improvements.

B. Viaud, Calo Mtg Aug. 31st 2011 1

Page 3: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Reminder

• Marie-Noelle (early May 2011) :

• there are too many alarms issued by the monitoring. Not all have real consequences.

• this brings Data Quality shifters vigilence down: they eventually overlook important issues.

• I surveyed 2011 monitoring data to determine what alarms are indeed to noisy and see what can be done.

B. Viaud, Calo Mtg Aug. 31st 2011 2

Page 4: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Survey of the monitors over 2011

• Most of the Monitoring is based on those monitors:

+ A few others based on collision data. 3

Page 5: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Survey of the monitors over 2011

• Most of the Monitoring is based on those monitors:

• Quantities like PMT's answer to a LED pulse, pedestal position, etc... measured in each cell:it's faulty if the average over n events is outside a certain range. The number of faulty cells determines the severity of the conclusion: warning/alarm/fatal

• This monitoring is repeated every 10-15 minutes. 4

Page 6: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Survey of the monitors over 2011

• I analyzed all the 15-minute savesets taken in 2011 (up to Aug. 13th, only physics fills, discard those created automatically at the end of a run);

• The goal is to count the number of warnings and alarms issued by each monitor, per unit of time (fill): spot those which "overwhelm" the DM.

• Action to be taken: to be discussed with the corresponding experts (re-tune the ranges and thresholds to reduce the nb of alarms while keeping the calo safe)

• Correlations are expected among the monitors: confirm them in practice. Correlated monitors can be grouped into a single item to simplify the DM's work.

• Scripts developped for this study can easily determine the effect of thresholds' variation.

5

Page 7: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Example: Ecal_Unexpected Signal

NB: All the other monitors shown in back-up

# of Savesets in the fill

# of Savesets at least in Warning

# of Savesets at least in Alarm

# of Savesets in Fatal.

Fill Number

# S

av

es

ets

6

Page 8: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Example: Ecal_Unexpected Signal

Normalized to the number

of fills in the Saveset

Fill Number

# S

av

es

ets

Fill 1806: 25-05-2011Fill 1613: 13-03-2011Fill 1944: 14-07-2011

Fill 2025: 13-08-2011

7

Page 9: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Correlated Monitors

• PedestalChi2 & PedestalAverageNoise alarms always accompanied by a PedestalNoise alarm;

• Most of the PedestalNoise & PedestalShiftOverNoise alarms accompanied by a PedestalShift alarm

Page 10: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Ecal_AveragePedestalNoise

Page 11: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Ecal_PedestalChi2

10

Page 12: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Ecal_PedestalNoise

Page 13: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Ecal_PedestalShiftOverNoise

Page 14: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Ecal_PedestalShift

13

Page 15: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Hcal_AveragePedestalNoise

Page 16: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Hcal_PedestalChi2

Page 17: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Hcal_PedestalNoise

16

Page 18: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Hcal_PedestalShift

Page 19: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Correlated Monitors

• PedestalChi2 & PedestalAverageNoise alarms always accompanied by a PedestalNoise alarm;

• Most of the PedestalNoise & PedestalShiftOverNoise alarms accompanied by a PedestalShift alarm

Group them into a single Pedestal alarm in the DM page. Keep the full picture in the Piquet page for finer diagnostics.

Page 20: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Correlated Monitors

• LEDNoise & LargeLEDNoise

• LowLEDSignal & OutRangeLED & NoGainMonitor

19

Page 21: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Ecal_LEDNoise

Page 22: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Ecal_LargeLEDNoise

Page 23: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Hcal_LEDNoise

22

Page 24: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Hcal_LargeLEDNoise

Page 25: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Ecal_LowLEDSignal

Page 26: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Ecal_OutRangeLED

25

Page 27: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Ecal_NoGainMonitor

Page 28: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Hcal_LowLEDSignal

Page 29: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Hcal_OutRangeLED

28

Page 30: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Hcal_NoGainMonitor

Page 31: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Correlated Monitors

• LEDNoise & LargeLEDNoise

• LowLEDSignal & OutRangeLED & NoGainMonitor

Group them into a single LEDNoise and a single NoGainMonitor

Page 32: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Even vs. Odd in Prs/Spd

Group Odd and

Even in DM plots.

31

Page 33: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Replace this:

Proposal

Page 34: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Proposal

By this :

Quite simpler for the DM.

Page 35: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Noisy Monitors

Now: study the pattern behind those alarms + discussions with experts to make them quieter and safe (ex: optimized ranges and thresholds).Next slides contain my first remarks.

Summing up all the alarms: something pretty much everyday

• Those which issue a Warning/Alarm/Fatal at least every few days;

• There are a few of them (see next slides);

34

Page 36: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Noisy Monitors

Page 37: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Noisy Monitors

Page 38: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Noisy Monitors

37

Page 39: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.
Page 40: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Noisy Monitors

• Some alarms appear simultaneously in many monitors ;• Happens when something a bit dramatic occurred (at leat something at all must have happened) ;• I guess we want those alarms; we should see to it that they’re still

there after monitoring ranges/thresholds have been optimized.

• Ex: Fills 1738, 1743, 1944

HCAL_LEDNoiseECAL_LEDNoise

Page 41: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Noisy Monitors

• Some alarms appear simultaneously in many monitors ;• Happens when something a bit dramatic occurred (at leat something at all must have happened) ;• I guess we want those alarms; we should see to it that they’re still

there after monitoring ranges/thresholds have been optimized.

• Fill 1944: right after LHCb restarted on July 14th, shortly after a power cut.

• Fill 1743: mis-Configuration of ODIN, LED pulsing in a physics BXID.

40

Page 42: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Noisy Monitors: Spd Fake Signal

I observe one faulty saveset every few hours, everything’s OK 15

minutes before/after. Instability in the pedestal ?

Most of the times, not very much above the Warning threshold.

Page 43: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Noisy Monitors: Prs PedestalMeans

• Shows up after LHCb restarted on July 14th + power cut.

FEB11 on crate 2 changed by Stephane ?

Page 44: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Noisy Monitors: Ecal/Prs Low Occupancy

• Other alarms are simultaneous for Ecal and Prs. Always (save one time) due to the very first saveset analyzed in the fill, typically 1 to 5 minutes after the start.

• PS2FEB11 is visible on the left of the PRS plot.

• Do they really appeared in the alarm section of the presenter ? If yes, discarding the first saveset will reduce a lot their rate. 43

Page 45: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Noisy Monitors

• Known for long. Find something to fix it…

Page 46: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Noisy Monitors

• Known for long. Find something to fix it…

1799,21/5/11 2040, 22/8/11

Page 47: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Summary and Prospects

• Surveyed 2011 monitoring data to find ways to reduce the number of alarms to be handled by the Shift Data Manager;

• Many alarms correlated/simultaneous: could group them into a single one;

• will require a bit of coding (create new monitoring histos): one of my next steps.

• A few monitors trigger an alarm every few days; combining everything, it means something almost every day. I’m presently having a look at that to determine if this can be re-optimized (less alarms and still safe).

• Scripts written for this study can be made available to the Piquets (after a bit of cleaning). Could be used every day to monitor in their whole the fills taken in the past 24 hours.

45

Page 48: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 49: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 50: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 51: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 52: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 53: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 54: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 55: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 56: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 57: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 58: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 59: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 60: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 61: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 62: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 63: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 64: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 65: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 66: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 67: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 68: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 69: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 70: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 71: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 72: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 73: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 74: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 75: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 76: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 77: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 78: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 79: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 80: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 81: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 82: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 83: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 84: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 85: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 86: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 87: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 88: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 89: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 90: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 91: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 92: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 93: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 94: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 95: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 96: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 97: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 98: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 99: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 100: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 101: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 102: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 103: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 104: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 105: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 106: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 107: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 108: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 109: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up

Page 110: Calorimeter Data Monitoring News Benoit Viaud (LAL-in2p3) B. Viaud, Calo Mtg Aug. 31 st 2011 0.

Back-up