IceBank® Energy StorageHybrid Cooling for the Future…and Beyond
IceBank® Energy StorageHybrid Cooling for the Future…and Beyond
CALMAC manufactures IceBank energy storage tanks. When IceBank tanks are added to a conventional
cooling system the storage tanks capture and store efficient half price nighttime electricity, of which a growing portion is comprised of
renewable wind energy. Here’s how…
IceBank® Energy StorageHybrid Cooling for the Future…and Beyond
At night the IceBank tanks are charged with a chiller using cheaper, more efficient, and cleaner night time electricity from the grid. Night time charging of ice tanks creates a load for renewable wind energy too, which blows mainly at night.
Emission Free Renewable Energy
Efficient Nighttime Grid Electricity
½ Price Nighttime Electricity
Distributed Stored ENERGY
IceBank® Energy StorageHybrid Cooling for the Future…and Beyond
At night the IceBank tanks are charged with a chiller using cheaper, more efficient, and cleaner night time electricity from the grid. Night time charging of ice tanks creates a load for renewable wind energy too, which blows mainly at night.
According to the Edison Electric Institute (EEI), off peak electricity is the only form of energy not to increase in price (when converted to today’s dollars) in the last 40 years.
IceBank® Energy StorageHybrid Cooling for the Future…and Beyond
During the day, the building is cooled in a conventional manner with electricity supplied from the grid which may contain renewable energy if available.
IceBank® Energy StorageHybrid Cooling for the Future…and Beyond
During the day, the building is cooled in a conventional manner with electricity supplied from the grid which may contain renewable energy if available.
As the day heats up the wind may subside and clouds may fill the sky reducing the renewable energy available and creating heavy electric demand.
FossilFuels
No Wind, Cloudy,
Hot, Humid
High Electricity Demand
Expensive Electricity
Grid Instability
Dirty Inefficient
Peaking Plants
IceBank® Energy StorageHybrid Cooling for the Future…and Beyond
As the cooling and occupancy peak occurs the demand for electricity becomes very high stressing the grid. When demand goes up, so does the price. Peaking units come on to improve reliability, but they tend to be expensive and dirty.
FossilFuels
No Wind, Cloudy,
Hot, Humid
High Electricity Demand
Expensive Electricity
Grid Instability
Dirty Inefficient
Peaking Plants
IceBank® Energy StorageHybrid Cooling for the Future…and Beyond
When cooling loads are excessive, costs and demand are high, the stored cooling is used, reducing the demand of the building on the grid while lowering cooling costs for the user20 – 40%.
FossilFuels
Reduce Cooling Costs
20-40%
Reduce Demand on
the Grid
Occupants Remain
Comfortable
Reduce GHG Emissions
Cooling Design Ready
for Future Revenue
IceBank® Energy StorageHybrid Cooling for the Future…and Beyond
When cooling loads are excessive, costs and demand are high, the stored cooling is used, reducing the demand of the building on the grid while lowering cooling costs for the user20 – 40%.
IceBank® Energy StorageHybrid Cooling for the Future…and Beyond
www.calmac.com 201-797-1511Over 4,000 projects in 35 countries
World Leader IceBank™ Energy Storage