Calibration Uncertainty Estimation Calibration Uncertainty Estimation for the Sfor the S--Parameter Measurements Parameter Measurements
at the Wafer Levelat the Wafer LevelA. Rumiantsev
SUSS MicroTec Test Systems GmbH Sussstr. 1, Sacka, D-01561, [email protected]
![Page 2: Calibration Uncertainty Estimation for the S-Parameter ...mtt11/workshops/IMS/2008/Applications_a… · Calibration Uncertainty Estimation for the S-parameter Measurements at the](https://reader033.fdocuments.net/reader033/viewer/2022060507/5f1fb657e2851b644e614060/html5/thumbnails/2.jpg)
Calibration Uncertainty Estimation for the S-parameter Measurements at the Wafer LevelA. Rumiantsev 2
Outline
• Motivation
• Error Sources
• Calibration Standards
• Calibration Procedures
• Uncertainty Analysis Methods
• Conclusion
![Page 3: Calibration Uncertainty Estimation for the S-Parameter ...mtt11/workshops/IMS/2008/Applications_a… · Calibration Uncertainty Estimation for the S-parameter Measurements at the](https://reader033.fdocuments.net/reader033/viewer/2022060507/5f1fb657e2851b644e614060/html5/thumbnails/3.jpg)
Calibration Uncertainty Estimation for the S-parameter Measurements at the Wafer LevelA. Rumiantsev 3
Motivation
Everybody’s dream: results with uncertainty budgets (error bars)
![Page 4: Calibration Uncertainty Estimation for the S-Parameter ...mtt11/workshops/IMS/2008/Applications_a… · Calibration Uncertainty Estimation for the S-parameter Measurements at the](https://reader033.fdocuments.net/reader033/viewer/2022060507/5f1fb657e2851b644e614060/html5/thumbnails/4.jpg)
Calibration Uncertainty Estimation for the S-parameter Measurements at the Wafer LevelA. Rumiantsev 4
Outline
• Motivation
• Error Sources
• Calibration Standards
• Calibration Procedures
• Uncertainty Analysis Methods
• Conclusion
![Page 5: Calibration Uncertainty Estimation for the S-Parameter ...mtt11/workshops/IMS/2008/Applications_a… · Calibration Uncertainty Estimation for the S-parameter Measurements at the](https://reader033.fdocuments.net/reader033/viewer/2022060507/5f1fb657e2851b644e614060/html5/thumbnails/5.jpg)
Calibration Uncertainty Estimation for the S-parameter Measurements at the Wafer LevelA. Rumiantsev 5
Error Sources
Reflection or transmission measurement:
r =Sii, t=Sij, i,j=1,2,3,…
Measurement results contain errors
![Page 6: Calibration Uncertainty Estimation for the S-Parameter ...mtt11/workshops/IMS/2008/Applications_a… · Calibration Uncertainty Estimation for the S-parameter Measurements at the](https://reader033.fdocuments.net/reader033/viewer/2022060507/5f1fb657e2851b644e614060/html5/thumbnails/6.jpg)
Calibration Uncertainty Estimation for the S-parameter Measurements at the Wafer LevelA. Rumiantsev 6
Error Sources
• Instability of the instrument and accessories– Temperature drift– Trace noise, etc.. – Cable phase instability– Contact repeatability (connections, probes)
• Non-ideal calibration standards – Modeling and fabrication tolerances
• Calibration and error correction method
![Page 7: Calibration Uncertainty Estimation for the S-Parameter ...mtt11/workshops/IMS/2008/Applications_a… · Calibration Uncertainty Estimation for the S-parameter Measurements at the](https://reader033.fdocuments.net/reader033/viewer/2022060507/5f1fb657e2851b644e614060/html5/thumbnails/7.jpg)
Calibration Uncertainty Estimation for the S-parameter Measurements at the Wafer LevelA. Rumiantsev 7
Outline
• Motivation
• Error Sources
• Calibration Standards
• Calibration Procedures
• Uncertainty Analysis Methods
• Conclusion
![Page 8: Calibration Uncertainty Estimation for the S-Parameter ...mtt11/workshops/IMS/2008/Applications_a… · Calibration Uncertainty Estimation for the S-parameter Measurements at the](https://reader033.fdocuments.net/reader033/viewer/2022060507/5f1fb657e2851b644e614060/html5/thumbnails/8.jpg)
Calibration Uncertainty Estimation for the S-parameter Measurements at the Wafer LevelA. Rumiantsev 8
Calibration Standards
• Distributed (transmission):– Dispersive– Frequency limited
(loop-back, etc)
• Lumped (reflection): – Not ideal– Insufficiently modeled– May not be symmetrical load open short
thru,lines
![Page 9: Calibration Uncertainty Estimation for the S-Parameter ...mtt11/workshops/IMS/2008/Applications_a… · Calibration Uncertainty Estimation for the S-parameter Measurements at the](https://reader033.fdocuments.net/reader033/viewer/2022060507/5f1fb657e2851b644e614060/html5/thumbnails/9.jpg)
Calibration Uncertainty Estimation for the S-parameter Measurements at the Wafer LevelA. Rumiantsev 9
Calibration Standards
• Fabrication tolerances:– Dielectric properties– Tolerances of the mask– Metal thickness and form
• Contact tolerances:– Positioning accuracy– Repeatability– Contact resistance Δ
![Page 10: Calibration Uncertainty Estimation for the S-Parameter ...mtt11/workshops/IMS/2008/Applications_a… · Calibration Uncertainty Estimation for the S-parameter Measurements at the](https://reader033.fdocuments.net/reader033/viewer/2022060507/5f1fb657e2851b644e614060/html5/thumbnails/10.jpg)
Calibration Uncertainty Estimation for the S-parameter Measurements at the Wafer LevelA. Rumiantsev 10
Outline
• Motivation
• Error Sources
• Calibration Standards
• Calibration Procedures
• Uncertainty Analysis Methods
• Conclusion
![Page 11: Calibration Uncertainty Estimation for the S-Parameter ...mtt11/workshops/IMS/2008/Applications_a… · Calibration Uncertainty Estimation for the S-parameter Measurements at the](https://reader033.fdocuments.net/reader033/viewer/2022060507/5f1fb657e2851b644e614060/html5/thumbnails/11.jpg)
Calibration Uncertainty Estimation for the S-parameter Measurements at the Wafer LevelA. Rumiantsev 11
Calibration Procedures
• SOLT calibration – Requires fully known (or ideal) standards
– 10-Term error model
• Self-calibration algorithms– TRL, LRM/LRM+, SOLR, QSOLT, RRMT+..
– 7-Term error model
– Some standards can be partly known
– Recommended for the wafer-level
![Page 12: Calibration Uncertainty Estimation for the S-Parameter ...mtt11/workshops/IMS/2008/Applications_a… · Calibration Uncertainty Estimation for the S-parameter Measurements at the](https://reader033.fdocuments.net/reader033/viewer/2022060507/5f1fb657e2851b644e614060/html5/thumbnails/12.jpg)
Calibration Uncertainty Estimation for the S-parameter Measurements at the Wafer LevelA. Rumiantsev 12
Calibration Procedures
SOLTSOLT SOLRSOLR QSOLTQSOLT TRLTRL LRMLRM RRMTRRMT
THRU(4 terms)
LINE(2 terms)
RECIP.(1 terms)
TERMS 44 11 44 66 44 44
Influence of transmission standards
![Page 13: Calibration Uncertainty Estimation for the S-Parameter ...mtt11/workshops/IMS/2008/Applications_a… · Calibration Uncertainty Estimation for the S-parameter Measurements at the](https://reader033.fdocuments.net/reader033/viewer/2022060507/5f1fb657e2851b644e614060/html5/thumbnails/13.jpg)
Calibration Uncertainty Estimation for the S-parameter Measurements at the Wafer LevelA. Rumiantsev 13
Calibration Procedures
SOLTSOLT SOLRSOLR QSOLTQSOLT TRLTRL LRMLRM RRMTRRMTOPEN OPEN
(1 terms)2x 2x
SHORTSHORT(1 terms)
2x 2x
LOADLOAD(1 terms)
2x 2x 2x 2x
REFLECTREFLECT(1 terms)
2x
TERMSTERMS 6 6 3 1 3 4
Influence of reflection (lumped) standards
![Page 14: Calibration Uncertainty Estimation for the S-Parameter ...mtt11/workshops/IMS/2008/Applications_a… · Calibration Uncertainty Estimation for the S-parameter Measurements at the](https://reader033.fdocuments.net/reader033/viewer/2022060507/5f1fb657e2851b644e614060/html5/thumbnails/14.jpg)
Calibration Uncertainty Estimation for the S-parameter Measurements at the Wafer LevelA. Rumiantsev 14
Outline
• Motivation
• Error Sources
• Calibration Standards
• Calibration Procedures
• Uncertainty Analysis Methods
• Conclusion
![Page 15: Calibration Uncertainty Estimation for the S-Parameter ...mtt11/workshops/IMS/2008/Applications_a… · Calibration Uncertainty Estimation for the S-parameter Measurements at the](https://reader033.fdocuments.net/reader033/viewer/2022060507/5f1fb657e2851b644e614060/html5/thumbnails/15.jpg)
Calibration Uncertainty Estimation for the S-parameter Measurements at the Wafer LevelA. Rumiantsev 15
Uncertainty Analysis Methods
1. Analysis of calibration standards– Statistical – Analytical
2. Calibration comparison method– Analysis with respect to the reference
calibration3. Measurement method
– Analysis with respect to the reference element• Classical ripple-test• Wafer-level implementation if the ripple-test
![Page 16: Calibration Uncertainty Estimation for the S-Parameter ...mtt11/workshops/IMS/2008/Applications_a… · Calibration Uncertainty Estimation for the S-parameter Measurements at the](https://reader033.fdocuments.net/reader033/viewer/2022060507/5f1fb657e2851b644e614060/html5/thumbnails/16.jpg)
Calibration Uncertainty Estimation for the S-parameter Measurements at the Wafer LevelA. Rumiantsev 16
Ad 1.: Analysis of Calibration Standards
• Statistical analysis– Specify uncertainty of standards– Run simulation (i.e. Monte-Carlo)– Apply results to the calibration procedure
• Analytical analysis– δSXY.DUT from deviations of error terms δETIJ
– δETIJ from deviations of standards δSST.XY
![Page 17: Calibration Uncertainty Estimation for the S-Parameter ...mtt11/workshops/IMS/2008/Applications_a… · Calibration Uncertainty Estimation for the S-parameter Measurements at the](https://reader033.fdocuments.net/reader033/viewer/2022060507/5f1fb657e2851b644e614060/html5/thumbnails/17.jpg)
Calibration Uncertainty Estimation for the S-parameter Measurements at the Wafer LevelA. Rumiantsev 17
Ad 2.: Calibration Comparison Method
• Requires two calibrations:– Reference (well-known)– Test
• Addresses variations in:– Calibration standards– Calibration methods – Measurement setup (drift)
• Results:– Max. error bounds
![Page 18: Calibration Uncertainty Estimation for the S-Parameter ...mtt11/workshops/IMS/2008/Applications_a… · Calibration Uncertainty Estimation for the S-parameter Measurements at the](https://reader033.fdocuments.net/reader033/viewer/2022060507/5f1fb657e2851b644e614060/html5/thumbnails/18.jpg)
Calibration Uncertainty Estimation for the S-parameter Measurements at the Wafer LevelA. Rumiantsev 18
Ad 2.: Calibration Comparison Method
[A] and [B] quantitatively describe the difference in TestTest and Reference Reference calibration
[A] REFREF [B]
Test CalibrationTest Calibration
ReferenceReferenceCalibrationCalibration
Test CalibrationTest Calibration
Block-diagram representation
![Page 19: Calibration Uncertainty Estimation for the S-Parameter ...mtt11/workshops/IMS/2008/Applications_a… · Calibration Uncertainty Estimation for the S-parameter Measurements at the](https://reader033.fdocuments.net/reader033/viewer/2022060507/5f1fb657e2851b644e614060/html5/thumbnails/19.jpg)
Calibration Uncertainty Estimation for the S-parameter Measurements at the Wafer LevelA. Rumiantsev 19
Ad 2.: Calibration Comparison Method
Example: verification of the system integrity*
*NIST Verify Program
0 10 20 30 40Frequency (GHz)
0
0.025
0.005
0.075
0.100
Max
|Sij-S
'ij|
FBH Instrument Drift
NIST Instrument Drift
Sum of FBH and NIST Drifts
Measurement Deviations
![Page 20: Calibration Uncertainty Estimation for the S-Parameter ...mtt11/workshops/IMS/2008/Applications_a… · Calibration Uncertainty Estimation for the S-parameter Measurements at the](https://reader033.fdocuments.net/reader033/viewer/2022060507/5f1fb657e2851b644e614060/html5/thumbnails/20.jpg)
Calibration Uncertainty Estimation for the S-parameter Measurements at the Wafer LevelA. Rumiantsev 20
Ad 2.: Calibration Comparison Method
Analysis of different coplanar calibrations
SUSS, 2007
![Page 21: Calibration Uncertainty Estimation for the S-Parameter ...mtt11/workshops/IMS/2008/Applications_a… · Calibration Uncertainty Estimation for the S-parameter Measurements at the](https://reader033.fdocuments.net/reader033/viewer/2022060507/5f1fb657e2851b644e614060/html5/thumbnails/21.jpg)
Calibration Uncertainty Estimation for the S-parameter Measurements at the Wafer LevelA. Rumiantsev 21
Ad 3.: Reference Measurements
• Reference element (coaxial applications): – Air-isolated lines– Well-defined characteristics: Z0, αl, βl
Picture source: NPL • Wafer-level equivalent?
![Page 22: Calibration Uncertainty Estimation for the S-Parameter ...mtt11/workshops/IMS/2008/Applications_a… · Calibration Uncertainty Estimation for the S-parameter Measurements at the](https://reader033.fdocuments.net/reader033/viewer/2022060507/5f1fb657e2851b644e614060/html5/thumbnails/22.jpg)
Calibration Uncertainty Estimation for the S-parameter Measurements at the Wafer LevelA. Rumiantsev 22
Ad 3.: Reference Measurements
Setup for the rq- calculation (ripple test)
• Reference measurements (ripple-test): – line, loaded with the short
• All errors are included in the final Source Match (as error vector rq)
![Page 23: Calibration Uncertainty Estimation for the S-Parameter ...mtt11/workshops/IMS/2008/Applications_a… · Calibration Uncertainty Estimation for the S-parameter Measurements at the](https://reader033.fdocuments.net/reader033/viewer/2022060507/5f1fb657e2851b644e614060/html5/thumbnails/23.jpg)
Calibration Uncertainty Estimation for the S-parameter Measurements at the Wafer LevelA. Rumiantsev 23
Classical Ripple Test
• Perfect VNA : Z0 = Zq
• Real VNA : Z0 ≠ Zq
![Page 24: Calibration Uncertainty Estimation for the S-Parameter ...mtt11/workshops/IMS/2008/Applications_a… · Calibration Uncertainty Estimation for the S-parameter Measurements at the](https://reader033.fdocuments.net/reader033/viewer/2022060507/5f1fb657e2851b644e614060/html5/thumbnails/24.jpg)
Calibration Uncertainty Estimation for the S-parameter Measurements at the Wafer LevelA. Rumiantsev 24
Wafer-Level Implementation
• Wafer-level challenge:
– Fabrication tolerances reduce accuracy
– Reference (planar) line is dispersive
• Solution:
I. Line characterization (e.g. NIST methods)
II. Renormalization from/to the line Z0
![Page 25: Calibration Uncertainty Estimation for the S-Parameter ...mtt11/workshops/IMS/2008/Applications_a… · Calibration Uncertainty Estimation for the S-parameter Measurements at the](https://reader033.fdocuments.net/reader033/viewer/2022060507/5f1fb657e2851b644e614060/html5/thumbnails/25.jpg)
Calibration Uncertainty Estimation for the S-parameter Measurements at the Wafer LevelA. Rumiantsev 25
Ad I: Characterization of Commercial CPW
• Measurement of the line’s C
• Definition of the line’s propagation constant γ(multiline TRL)*
• Calculation of the line’s Z0:
CjZ0 ω
γ≅
*Available from MultiCal software package, NIST
![Page 26: Calibration Uncertainty Estimation for the S-Parameter ...mtt11/workshops/IMS/2008/Applications_a… · Calibration Uncertainty Estimation for the S-parameter Measurements at the](https://reader033.fdocuments.net/reader033/viewer/2022060507/5f1fb657e2851b644e614060/html5/thumbnails/26.jpg)
Calibration Uncertainty Estimation for the S-parameter Measurements at the Wafer LevelA. Rumiantsev 26
Ad I: Characterization of Commercial CPW
Measurement results
0 20 40 60 80 100
Frequency (GHz)
Re(
Zo),
Ohm
45
47.5
50
52.5
55
Sub A Sub B CSR-8
![Page 27: Calibration Uncertainty Estimation for the S-Parameter ...mtt11/workshops/IMS/2008/Applications_a… · Calibration Uncertainty Estimation for the S-parameter Measurements at the](https://reader033.fdocuments.net/reader033/viewer/2022060507/5f1fb657e2851b644e614060/html5/thumbnails/27.jpg)
Calibration Uncertainty Estimation for the S-parameter Measurements at the Wafer LevelA. Rumiantsev 27
Ad II: Renormalization
Return loss of the reference line
0 20 40 60 80 100 120-80
-70
-60
-50
-40
-30
-20
Frequency (GHz)
|S11|,
(dB)
50 OhmRenormalized
Automated ripple-test can be applied
![Page 28: Calibration Uncertainty Estimation for the S-Parameter ...mtt11/workshops/IMS/2008/Applications_a… · Calibration Uncertainty Estimation for the S-parameter Measurements at the](https://reader033.fdocuments.net/reader033/viewer/2022060507/5f1fb657e2851b644e614060/html5/thumbnails/28.jpg)
Calibration Uncertainty Estimation for the S-parameter Measurements at the Wafer LevelA. Rumiantsev 28
Uncertainty Estimation: LRM+ Calibration
Measurement results of a 25Ω resistor
0 20 40 60 80 100 120
-10.2
-9.8
-9.4
-9
-8.6
Frequency, (GHz)
|S11|,
(dB)
25Ω CPW Resistor
![Page 29: Calibration Uncertainty Estimation for the S-Parameter ...mtt11/workshops/IMS/2008/Applications_a… · Calibration Uncertainty Estimation for the S-parameter Measurements at the](https://reader033.fdocuments.net/reader033/viewer/2022060507/5f1fb657e2851b644e614060/html5/thumbnails/29.jpg)
Calibration Uncertainty Estimation for the S-parameter Measurements at the Wafer LevelA. Rumiantsev 29
Uncertainty Estimation: LRM+ Calibration
Measurement results of a 25Ω resistor
0 20 40 60 80 100 120150
155
160
165
170
175
180
Frequency, (GHz)
Arg
(S11),
(d
egre
e)
25Ω CPW Resistor
![Page 30: Calibration Uncertainty Estimation for the S-Parameter ...mtt11/workshops/IMS/2008/Applications_a… · Calibration Uncertainty Estimation for the S-parameter Measurements at the](https://reader033.fdocuments.net/reader033/viewer/2022060507/5f1fb657e2851b644e614060/html5/thumbnails/30.jpg)
Calibration Uncertainty Estimation for the S-parameter Measurements at the Wafer LevelA. Rumiantsev 30
Outline
• Motivation
• Error Sources
• Calibration Standards
• Calibration Procedures
• Uncertainty Analysis Methods
• Conclusion
![Page 31: Calibration Uncertainty Estimation for the S-Parameter ...mtt11/workshops/IMS/2008/Applications_a… · Calibration Uncertainty Estimation for the S-parameter Measurements at the](https://reader033.fdocuments.net/reader033/viewer/2022060507/5f1fb657e2851b644e614060/html5/thumbnails/31.jpg)
Calibration Uncertainty Estimation for the S-parameter Measurements at the Wafer LevelA. Rumiantsev 31
Conclusion
• Multiple sources of calibration errors
• Different analysis methods are available
• Characterized CPW lines can be used as reference elements
• Results of the automated wafer-level ripple-test were demonstrated
![Page 32: Calibration Uncertainty Estimation for the S-Parameter ...mtt11/workshops/IMS/2008/Applications_a… · Calibration Uncertainty Estimation for the S-parameter Measurements at the](https://reader033.fdocuments.net/reader033/viewer/2022060507/5f1fb657e2851b644e614060/html5/thumbnails/32.jpg)
Calibration Uncertainty Estimation for the S-parameter Measurements at the Wafer LevelA. Rumiantsev 32
ReferencesEuropean co-operation for Accreditation, Expression of the Uncertainty of Measurement in
Calibration, EA-4/02, 12.1999.Eul, H.J., Schiek, B., A Generalized Theory and New Calibration Procedures for Network
Analyzer Self-Calibration, IEEE Trans. Microwave Theory Tech., MTT-39, Apr. 1991, pp. 724-731.
Heuermann, H., Schiek, B., Robust Algorithms for Txx Network Analyzer Procedures, IEEE Trans. Instrum. Meas., Feb. 1994, pp. 18-23.
Marks, R., Williams, D., Characteristic Impedance Determination Using Propagation Constant Measurements, IEEE Microwave and Guided Wave Lett., vol. 1, pp. 141-143, June 1991.
A. Rumiantsev, H. Heuermann, S. Schott, A Robust Broadband Calibration Method for Wafer-Level Characterization of Multiport Devices, 69th ARFTG Conference Digest, June 2007
Rumiantsev, A., Doerner, R., Thies, S., Calibration Standards Verification Procedure Using the Calibration Comparison Technique, 36th European Microwave Conference Digest, September 2006.
U. Arz, Traceability for On-Wafer S-Parameter Measurements, Workshop Determining Accuracy of Measurements at High Frequencies – from Error to Uncertainty, 37th European Microwave Conference, 2007.
R. Doerner, "Evaluation of wafer-level LRRM and LRM+ calibration techniques," ARFTG Microwave Measurements Conference-Spring, 69th, 2007.
![Page 33: Calibration Uncertainty Estimation for the S-Parameter ...mtt11/workshops/IMS/2008/Applications_a… · Calibration Uncertainty Estimation for the S-parameter Measurements at the](https://reader033.fdocuments.net/reader033/viewer/2022060507/5f1fb657e2851b644e614060/html5/thumbnails/33.jpg)
Calibration Uncertainty Estimation for the S-parameter Measurements at the Wafer LevelA. Rumiantsev 33
References (cont.)J. P. Hoffmann, P. Leuchtmann, J. Schaub, and R. Vahldieck, "Computing uncertainties of S-
parameters by means of monte carlo simulation," in ARFTG Microwave Measurements Conference-Fall, 69th, 2007
N. M. Ridler, A. G. Morgan, and M. J. Sadler, "Generalized adaptive calibration schemes for RF network analyzers based on minimizing the uncertainty of measurement,“ ARFTG Microwave Measurements Conference-Digest-Fall, 60th, 2002, pp. 1-9.
U. Stumper, "Influence of TMSO calibration standards uncertainties on VNA S-parameter measurements," Instrumentation and Measurement, IEEE Transactions on, vol. 52, pp. 311-315, 2003.
U. Stumper, "Uncertainties of VNA S-parameter measurements applying the TAN self-calibration method," Instrumentation and Measurement, IEEE Transactions on, vol. 56, pp. 597-600, 2007.
RF & Microwave Test Solutions, SUSS MicroTec Test Systems GmbH, 2007.Heuermann, H., Old and New Accuracy Estimation of S-Parameter Measurements with the
Ripple-Test, MTT-S International Microwave Symposium Workshop TMB, San Francisco, Juni 2006.
H. Heuermann and A. Rumiantsev, "The modified ripple test for on-wafer S-parameter measurements," ARFTG Microwave Measurements Conference-Spring, 69th, 2007.