Cables Industria Petrolera LS Cable

34
Offshore & Marine Cable www.lscable.com 14F, LS Tower, 1026-6, Hogye-dong, Dongan-gu, Anyang-si, Gyeonggi-do, 431-080, Korea Tel. 82-2-2189-9114 [email protected] 2008 LS Cable, Ltd. All right reserved. This product or document is protected by copyright and distributed under licenses restricting its use, copying, distribution, and decompilation. No part of this product or document may be reproduced in any form by any means without prior written authorization of LS Cable and its licensors, if any. Leading Solution

description

Cables eléctricos para industria petrolera. LS Cable

Transcript of Cables Industria Petrolera LS Cable

Page 1: Cables Industria Petrolera LS Cable

Offshore & Marine Cable

www.lscable.com14F, LS Tower, 1026-6, Hogye-dong, Dongan-gu, Anyang-si, Gyeonggi-do, 431-080, KoreaTel. 82-2-2189-9114 [email protected]

2008 LS Cable, Ltd. All right reserved. This product or document is protected by copyright and distributed under licenses restricting its use, copying, distribution, and decompilation. No part of this product or document may be reproduced in any form by any means without prior written authorization of LS Cable and its licensors, if any.

Leading Solution

Page 2: Cables Industria Petrolera LS Cable

3

Always with our customers

LS Cable is leading the cable, telecommunication industry. It also represents the LS Group. With its company vision, “Always with our customers.” LS Cable continuously drives towardsbecoming the global leading company providing the technology asrequired by customers and the solution that others cannot offer.

Towards the global leading company

All employees of LS Cable stand behind the vision of becoming Your No.1Creative Partner and are doing their best to realize our customers’ satisfac-tion. Securing and establishing a firm growth engine, LS Cable will bereborn as an enterprise to leap worldwide

Telecommunication Business

Reserch & Development

Electric PowerBusiness

Main energy arterylightening the world

Human communication connecting minds

Awakening and changing prime power

Leading SolutionLS aims to develop into a company that provides its clients with a Leading Solution,

contributes to the overall society,and offers a business environment where the employees can realize their dreams.

Page 3: Cables Industria Petrolera LS Cable

Cable ProductsOffshore & Marine CableAs a telecommunication cable manufacturer and a division of LS Cable,LS Data Communication Product and Components never stops research-ing, designing, developing, and manufacturing products with the higherlevel of quality to address the ever-changing demands in everyday life aswell as in the industry.

Our quality control meets the most delicate requirements of internationalstandards and the high level of quality is recognized both by local andinternational clients.

Our commitment to develop and deliver solutions to address our cus-tomers’ needs and challenges keep our technology on the cutting edgeand our know-how in the field more valuable, which our customers highlyappreciate. We are looking forward to working with you.

ContentsPower Distribution Cable

Power Distribution Cable - 2kV Power Distribution Cable - 0.6/1kV

0.6/1kV Control Cable0.6/1kV Control Cable - Non Shield

0.6/1kV Control Cable - Overall Shield0.6/1kV Control Cable - Overall Braid Shield

0.6/1kV Signal Cable0.6/1kV Signal Cable - Overall Shield

0.6/1kV Signal Cable - Overall Braid Shield0.6/1kV Signal Cable - Individual Shield

0.6/1kV Signal Cable - Individual & Overall Shield

High Voltage Power CableHigh Voltage Power Cable - 5kV, 8kV, 15kV

Technical Data & Installation InformationTechnical Data

Installation InformationNetwork

Page 4: Cables Industria Petrolera LS Cable

Power Distribution Cable

Cable Designation

Example

AL/PS Tape : Aluminum backed polyester tape

According to IEEE 1580(2001), IEEE 45(2002)

Cable Type

S Single - Conductor Distribution C Control

D Two - Conductor Distribution TP Twisted Pair

T Three -Conductor Distribution TT Twisted Triad

F Four - Conductor Distribution FS Fire Resistant

Q Five - Conductor Distribution

GroupShielding

(None) Unshielded (OBS) Overall Tinned Copper Braid Shielded

(OS) Overall Shield (IS-OBS) Individually Shielded and Overall Tinned

(IS) Individually Shielded Copper Braid Shielded

(IS-OS) Individually Shielded and Overall Shielded

InsulationType

E Ethylene Propylene Rubber S Silicone Rubber

X Cross-Linked Polyethylene P Cross-linked Polyolefin

T Polyvinyl Chloride LSX Low - smoke Cross-linked Polyolefin

T/N Polyvinyl Chloride / Nylon LSE Low - smoke Ethylene Propylene Rubber

Jacket and / orSheath Type

T Thermoplastic Polyvinyl Chloride L Cross-linked Polyolefin (Low-smoke)

CP Thermosetting Chlorosulfonated Polyethylene(Hypalon)

N Thermosetting Polychloroprene(neoprene) TPO Thermoplastic Polyolefin (Low-smoke)

M Mud resistant Cross-linked Polyolefin

Armor(None) Unarmored T Tin-coated Copper

A Aluminum S Armor with Sheath

B Bronze

Power Distribution Cable - 0.6/1kV Power Distribution Cable - 2kv

0.6/1kV TP (I/S - OS) PNBSVoltage

Twisted Pair

Insulation(Type P)

Individually Shielded(AL/PS Tape)

Overall Shielded(AL/PS Tape)

Jacket(Neoprene)

Armor(Bronze)

Sheath(Neoprene)

Voltage

Fire Resisrant Layer

No. of Conductor(Three)

Insulation(Type P)

Jacket(Neoprene)

Armor(Bronze)

Sheath(Neoprene)

0.6/1kV FS - TPNBS

Page 5: Cables Industria Petrolera LS Cable

Power Distribution Cable- 2kV

Offshore & Marine Cable 10

Power Distribution Cable0.6/1kV Control Cable

0.6/1kV Signal CableHigh Voltage Power Cable

Technical Data

9

Power Distribution Cable - 2kV

Cable Contruction1. CONDUCTOR : TINNED ANNEALED ROPE-LAY STRANDED COPPER2. SEPARATOR TAPE (if necessary)3. INSULATION(TYPE P ACCORDING TO IEEE 1580)4. ARMOR : BRONZE WIRE BRAID

*Suitable tape may be applied over / under braid armor5. JACKET : ARCTIC NEOPRENE

SPBS2kV(HD)

No.

of coresConductor

size

SP2kV(HD), SPB2kV(HD), SPB2kV(HD)

AWG/MCM

Composition Conductordiameter

Nos/AWG mm inch

Insulationthickness

mm inch

Sheaththickness

mm

Impedance(Phase-Neutral)

/km /1000ftinch

Overalldiameter

mm inch

ApproxWeight

kg/km

Conductor Unamor

Overalldiameter

mm inch

ApproxWeight

kg/km

Armor

Overalldiameter

mm inch

ApproxWeight

kg/km

Armor & Sheath

Inductance

/km /1000ft

Reactance

/km /1000ft

Capacitance

/km /1000ft

1

No.

of coresConductor

size

SP2kV, SPB2kV, SPBS2kV

AWG/MCM

Composition Conductordiameter

Nos/AWG mm inch

Insulationthickness

mm inch

Sheaththickness

mm

Impedance(Phase-Neutral)

/km /1000ftinch

Overalldiameter

mm inch

ApproxWeight

kg/km

Conductor Unamor

Overalldiameter

mm inch

ApproxWeight

kg/km

Armor

Overalldiameter

mm inch

ApproxWeight

kg/km

Armor & Sheath

Inductance

/km /1000ft

Reactance

/km /1000ft

Capacitance

/km /1000ft

Cable Designation / 2kVSP2kV(HD), SPB2kV(HD), SPBS2kV(HD)SP2kV, SPB2kV, SPBS2kV0.6 / 1kV SP, 0.6 / kV SPB, 0.6 / 1kV SPBS

Application Suitable for use in commercial marine applications, MODU's & PlatformOnshore and offshore drilling platformsFPSO, etc.

Applied Standards & FeaturesIEEE 1580(2001)IEEE 45(2002)UL 1309 / CSA C 22.2 No.245(1995)

100 (IEEE 1580 TYPE P)110 (UL 1309 / CSA C 22.2 No.245)FLEXEN 125 (UL 758 125)

Standards

Rating

Flame retardant : IEC 60332-3-22 CAT.A / IEEE 1202Cold resistant : CSA C 22.2 No.38(at -40 )Drilling Mud Resistant(Water & oil based Mud) : NEK 606(2004) & IEC 60092-350 Ed. 3.0(2008)Crush & Impact resistant : UL 1569 & UL 2227Excellent resistance to oil, abrasion, petrochemical fluids, moisture & sunlight.Low smoke version available (Type LSX, LSE, TPO & L)Superior flexibility

Feature

1

Page 6: Cables Industria Petrolera LS Cable

Power Distribution Cable - 0.6/1kV

Applied Standards & FeaturesIEEE 1580(2001)IEEE 45(2002)UL 1309 / CSA C 22.2 No.245(1995)

100 (IEEE 1580 TYPE P)110 (UL 1309 / CSA C 22.2 No.245)FLEXEN 125 (UL 758 125)

Standards

Rating

Flame retardant : IEC 60332-3-22 CAT.A / IEEE 1202Cold resistant : CSA C 22.2 No.38(at -40 )Drilling Mud Resistant(Water & oil based Mud) : NEK 606(2004) & IEC 60092-350 Ed. 3.0(2008)Crush & Impact resistant : UL 1569 & UL 2227Excellent resistance to oil, abrasion, petrochemical fluids, moisture & sunlight.Low smoke version available (Type LSX, LSE, TPO & L)Superior flexibility

Cable Contruction1. CONDUCTOR : TINNED ANNEALED ROPE-LAY STRANDED COPPER2. SEPARATOR TAPE(if necessary)3. INSULATION(TYPE P ACCORDING TO IEEE 1580)4. FILLER5. BINDER TAPE6. JACKET : ARCTIC NEOPRENE7. ARMOR : BRONZE WIRE BRAID

*Suitable tape may be applied over / under braid armor8. JACKET : ARCTIC NEOPRENE DPNBS, TPNBS, FPNBS

Cable Designation / 0.6/1kV0.6/1kV SPN0.6/1kV DPN, 0.6/1kV DPNBS0.6/1kV TPN, 0.6/1kV TPNBS0.6/1kV FPN, 0.6/1kV FPNBS0.6/1kV QPN, 0.6/1kV QPNBS

Application Suitable for use in commercial marine applications, MODU's & PlatformOnshore and offshore drilling platformsFPSO, etc.

Feature

Offshore & Marine Cable 12

Power Distribution Cable0.6/1kV Control Cable

0.6/1kV Signal CableHigh Voltage Power Cable

Technical Data

Power Distribution Cable- 2kv

11

No.

of coresConductor

size

0.6/1kV SP, 0.6/1kV SPB, 0.6/1kV SPBS

AWG/MCM

Composition Conductordiameter

Nos/AWG mm inch

Insulationthickness

mm inch

Sheaththickness

mm

Impedance(Phase-Neutral)

/km /1000ftinch

Overalldiameter

mm inch

ApproxWeight

kg/km

Conductor Unamor

Overalldiameter

mm inch

ApproxWeight

kg/km

Armor

Overalldiameter

mm inch

ApproxWeight

kg/km

Armor & Sheath

Inductance

/km /1000ft

Reactance

/km /1000ft

Capacitance

/km /1000ft

1

Power Distribution Cable- 0.6/1kV

Page 7: Cables Industria Petrolera LS Cable

Offshore & Marine Cable 14

Power Distribution Cable0.6/1kV Control Cable

0.6/1kV Signal CableHigh Voltage Power Cable

Technical Data

Power Distribution Cable- 0.6/1kV

13

No.

of coresConductor

size

0.6/1kV SPN 0.6/1kV TPN, 0.6/1kV TPNBS

AWG/MCM

Composition Conductor diameterInsulation thickness

Nos/AWG mm inch

Conductor

mm inch

Sheath thickness

mm inch

Overalldiameter

mm

ApproxWeight

kg/km

Impedance(Phase-Neutral)

/km /1000ftinch

Inductance

/km /1000ft

Reactance

/km /1000ft

Capacitance

/km /1000ft

1

No.

of coresConductor

size

0.6/1kV DPN, 0.6/1kV DPNBS

AWG/MCM

Composition Conductordiameter

Nos/AWG mm inch

Insulationthickness

mm inch

Jacketthickness

Sheaththickness

mm

Impedance(Phase-Neutral)

/km /1000ftinch mm inch

Conductor

Overalldiameter

mm inch

ApproxWeight

kg/km

Unamor

Overalldiameter

mm inch

ApproxWeight

kg/km

Armor & Sheath

Inductance

/km /1000ft

Reactance

/km /1000ft

Capacitance

/km /1000ft

2

14

No.

of coresConductor

size

0.6/1kV FPN, 0.6/1kV FPNBS

AWG/MCM

Composition Conductordiameter

Nos/AWG mm inch

Insulationthickness

mm inch

Jacketthickness

Sheaththickness

mm

Impedance(Phase-Neutral)

/km /1000ftinch mm inch

Conductor

Overalldiameter

mm inch

ApproxWeight

kg/km

Unamor

Overalldiameter

mm inch

ApproxWeight

kg/km

Armor & Sheath

Inductance

/km /1000ft

Reactance

/km /1000ft

Capacitance

/km /1000ft

4

14

No.

of coresConductor

size

AWG/MCM

Composition Conductordiameter

Nos/AWG mm inch

Insulationthickness

mm inch

Jacketthickness

Sheaththickness

mm

Impedance(Phase-Neutral)

/km /1000ftinch mm inch

Conductor

Overalldiameter

mm inch

ApproxWeight

kg/km

Unamor

Overalldiameter

mm inch

ApproxWeight

kg/km

Armor & Sheath

Inductance

/km /1000ft

Reactance

/km /1000ft

Capacitance

/km /1000ft

3

Page 8: Cables Industria Petrolera LS Cable

Offshore & Marine Cable 16

Power Distribution Cable0.6/1kV Control Cable

0.6/1kV Signal CableHigh Voltage Power Cable

Technical Data

Power Distribution Cable- 0.6/1kV

Power Distribution Cable- 2kV

15

0.6/1kV QPN, 0.6/1kV QPNBS

15

No.

of coresConductor

size

AWG/MCM

Composition Conductordiameter

Nos/AWG mm inch

Insulationthickness

mm inch

Jacketthickness

Sheaththickness

mm

Impedance(Phase-Neutral)

/km /1000ftinch mm inch

Conductor

Overalldiameter

mm inch

ApproxWeight

kg/km

Unamor

Overalldiameter

mm inch

ApproxWeight

kg/km

Armor & Sheath

Inductance

/km /1000ft

Reactance

/km /1000ft

Capacitance

/km /1000ft

5

Power Distribution Cable - 2kV

Applied Standards & FeaturesIEEE 1580(2001)IEEE 45(2002)UL 1309 / CSA C 22.2 No.245(1995)

100 (IEEE 1580 TYPE P)110 (UL 1309 / CSA C 22.2 No.245)FLEXEN 125 (UL 758 125)

Standards

Rating

Flame retardant : IEC 60332-3-22 CAT.A / IEEE 1202Cold resistant : CSA C 22.2 No.38(at -40 )Drilling Mud Resistant(Water & oil based Mud) : NEK 606(2004) & IEC 60092-350 Ed. 3.0(2008)Crush & Impact resistant : UL 1569 & UL 2227Excellent resistance to oil, abrasion, petrochemical fluids, moisture & sunlight.Low smoke version available (Type LSX, LSE, TPO & L)Superior flexibility

Cable Contruction1. CONDUCTOR : TINNED ANNEALED ROPE-LAY STRANDED COPPER2. SEPARATOR TAPE (if necessary)3. INSULATION : TYPE P ( ACCORDING TO IEEE 1580)4. FILLER : NON-HYGROSCOPIC MATERIAL (IF NECESSARY)5. SHIELD : TINNED COPPER WIRE BRAID PLUS ALUMINUM LAMINATED POLYESTER TAPE (SB/AMS)6. JACKET: ARCTIC NEOPRENE7. ARMOR : BRONZE WIRE BRAID8. JACKET: ARCTIC NEOPRENE

TPNBS-SB/AMS

Cable Designation / 2kV2KV TPNBS-SB/AMS

Application Suitable for use in commercial marine applications, MODU's & PlatformOnshore and offshore drilling platformsFPSO, etc.

Feature

Page 9: Cables Industria Petrolera LS Cable

Power Distribution Cable- 2kV

17

2kV TPNBS-SB/AMS

No.

of coresConductor

size

AWG/MCM

Composition Conductordiameter

Nos/AWG mm inch

Insulationthickness

mm inch

Jacketthickness

Sheaththickness

mm

Impedance(Phase-Neutral)

/km /1000ftinch mm inch

ConductorOverall

diameter

mm inch

ApproxWeight

kg/km

Inductance

/km /1000ft

Reactance

/km /1000ft

Capacitance

/km /1000ft

3+3

0.6/1kV Control Cable0.6/1kV Control Cable - With Overall Shield0.6/1kV Control Cable - Non Shield

0.6/1kV Control Cable - With Overall Braid Shield

Page 10: Cables Industria Petrolera LS Cable

Offshore & Marine Cable 20

Power Distribution Cable0.6/1kV Control Cable

0.6/1kV Signal CableHigh Voltage Power Cable

Technical Data

0.6/1kV Control Cable- Non shield

19

0.6/1kV Control Cable - Non shield

Cable Contruction1. CONDUCTOR : TINNED ANNEALED ROPE-LAY STRANDED COPPER2. SEPARATOR TAPE (if necessary)3. INSULATION(TYPE P ACCORDING TO IEEE 1580)4. FILLER5. JACKET: ARCTIC NEOPRENE6. ARMOR : BRONZE WIRE BRAID

*Suitable tape may be applied over / under braid armor7. JACKET: ARCTIC NEOPRENE

C(10,12,14,16,18)TNBS

0.6/1kV C10PN, 0.6/1kV C10PNBSCable Designation / 0.6/1kV

0.6/1kV C10PN, 0.6/1kV C10PNBS0.6/1kV C12PN, 0.6/1kV C12PNBS0.6/1kV C14PN, 0.6/1kV C14PNBS0.6/1kV C16PN, 0.6/1kV C16PNBS0.6/1kV C18PN, 0.6/1kV C18PNBS

Application Suitable for use in commercial marine applications, MODU's & PlatformOnshore and offshore drilling platformsFPSO, etc.

Applied Standards & FeaturesIEEE 1580(2001)IEEE 45(2002)UL 1309 / CSA C 22.2 No.245(1995)

100 (IEEE 1580 TYPE P)110 (UL 1309 / CSA C 22.2 No.245)FLEXEN 125 (UL 758 125)

Standards

Rating

Flame retardant : IEC 60332-3-22 CAT.A / IEEE 1202Cold resistant : CSA C 22.2 No.38(at -40 )Drilling Mud Resistant(Water & oil based Mud) : NEK 606(2004) & IEC 60092-350 Ed. 3.0(2008)Crush & Impact resistant : UL 1569 & UL 2227Excellent resistance to oil, abrasion, petrochemical fluids, moisture & sunlight.Low smoke version available (Type LSX, LSE, TPO & L)Superior flexibility

Feature

No.

of coresConductor

size

AWG/MCM

Compostion Conductor diameter

Nos/AWG mm inch

ConductorInsulationthickness

mm inch

Jacketthickness

mm

Sheaththickness

Unarmor

Overalldiameter

mm mm kg/kminch inchinch

Approx.Weight

Armor & Sheath

Overalldiameter

mm kg/kminch

Approx.Weight

2

3

4

5

6

7

10

12

14

16

19

20

24

30

37

44

60

91

0.6/1kV C12PN, 0.6/1kV C12PNBS

No.

of coresConductor

size

AWG/MCM

Compostion Conductor diameter

Nos/AWG mm inch

ConductorInsulationthickness

mm inch

Jacketthickness

mm

Sheaththickness

Unarmor

Overalldiameter

mm mm kg/kminch inchinch

Approx.Weight

Armor & Sheath

Overalldiameter

mm kg/kminch

Approx.Weight

2

3

4

5

6

7

10

12

14

16

19

20

24

30

37

44

60

91

Page 11: Cables Industria Petrolera LS Cable

Offshore & Marine Cable 22

Power Distribution Cable0.6/1kV Control Cable

0.6/1kV Signal CableHigh Voltage Power Cable

Technical Data

600V Control Cable- Non shield

21

0.6/1kV C14PN, 0.6/1kV C14PNBS

No.

of coresConductor

size

AWG/MCM

Composition Conductor diameter

Nos/AWG mm inch

ConductorInsulationthickness

mm inch

Jacketthickness

mm

Sheaththickness

Unarmor

Overalldiameter

mm mm kg/kminch inchinch

Approx.Weight

Armor & Sheath

Overalldiameter

mm kg/kminch

Approx.Weight

2

3

4

5

6

7

10

12

14

16

19

20

24

30

37

44

60

91

0.6/1kV C18PN, 0.6/1kV C18PNBS

No.

of coresConductor

size

AWG/MCM

Composition Conductor diameter

Nos/AWG mm inch

ConductorInsulationthickness

mm inch

Jacketthickness

mm

Sheaththickness

Unarmor

Overalldiameter

mm mm kg/kminch inchinch

Approx.Weight

Armor & Sheath

Overalldiameter

mm kg/kminch

Approx.Weight

2

3

4

5

6

7

8

10

12

14

16

18

20

22

24

37

44

60

91

0.6/1kV C16PN, 0.6/1kV C16PNBS

No.

of coresConductor

size

AWG/MCM

Composition Conductor diameter

Nos/AWG mm inch

ConductorInsulationthickness

mm inch

Jacketthickness

mm

Sheaththickness

Unarmor

Overalldiameter

mm mm kg/kminch inchinch

Approx.Weight

Armor & Sheath

Overalldiameter

mm kg/kminch

Approx.Weight

2

3

4

5

6

7

8

10

12

14

16

18

20

22

24

37

44

60

91

Page 12: Cables Industria Petrolera LS Cable

0.6/1kV Control Cable - With Overall Shield

Cable Contruction

0.6/1kV C(OS)10PN, 0.6/1kV C(OS)10PNBS

Applied Standards & FeaturesIEEE 1580(2001)IEEE 45(2002)UL 1309 / CSA C 22.2 No.245(1995)

100 (IEEE 1580 TYPE P)110 (UL 1309 / CSA C 22.2 No.245)FLEXEN 125 (UL 758 125)

Standards

Rating

Flame retardant : IEC 60332-3-22 CAT.A / IEEE 1202Cold resistant : CSA C 22.2 No.38(at -40 )Drilling Mud Resistant(Water & oil based Mud) : NEK 606(2004) & IEC 60092-350 Ed. 3.0(2008)Crush & Impact resistant : UL 1569 & UL 2227Excellent resistance to oil, abrasion, petrochemical fluids, moisture & sunlight.Low smoke version available (Type LSX, LSE, TPO & L)Superior flexibility

Feature

No.

of coresConductor

size

AWG/MCM

Composition Conductor diameter

Nos/AWG mm inch

ConductorInsulationthickness

mm inch

Jacketthickness

mm

Sheaththickness

Unarmor

Overalldiameter

mm mm kg/kminch inchinch

Approx.Weight

Armor & Sheath

Overalldiameter

mm kg/kminch

Approx.Weight

2

3

4

5

6

7

10

12

14

16

19

20

24

30

37

44

60

91

0.6/1kV C(OS)12PN, 0.6/1kV C(OS)12PNBS

No.

of coresConductor

size

AWG/MCM

Composition Conductor diameter

Nos/AWG mm inch

ConductorInsulationthickness

mm inch

Jacketthickness

mm

Sheaththickness

Unarmor

Overalldiameter

mm mm kg/kminch inchinch

Approx.Weight

Armor & Sheath

Overalldiameter

mm kg/kminch

Approx.Weight

2

3

4

5

6

7

10

12

14

16

19

20

24

30

37

44

60

91

Offshore & Marine Cable 24

Power Distribution Cable0.6/1kV Control Cable

0.6/1kV Signal CableHigh Voltage Power Cable

Technical Data

0.6/1kV Control Cable- With Overall Shield

23

Cable Designation / 0.6/1kV0.6/1kV C(OS)10PN, 0.6/1kV C(OS)10PNBS0.6/1kV C(OS)12PN, 0.6/1kV C(OS)12PNBS0.6/1kV C(OS)14PN, 0.6/1kV C(OS)14PNBS0.6/1kV C(OS)16PN, 0.6/1kV C(OS)16PNBS0.6/1kV C(OS)18PN, 0.6/1kV C(OS)18PNBS0.6/1kV C(OS)20PN, 0.6/1kV C(OS)20PNBS

Application Suitable for use in commercial marine applications, MODU's & PlatformOnshore and offshore drilling platformsFPSO, etc.

1. CONDUCTOR : TINNED ANNEALED ROPE-LAY STRANDED COPPER*For fire resisting cables, FS-type, mica tape shall be applied over the conductor as a fire proof layer

2. SEPARATOR TAPE (if necessary)3. INSULATION(TYPE P ACCORDING TO IEEE 1580)4. FILLER5. SHIELDING: ALUMINUM POLYESTER TAPE6. DRAIN WIRE7. JACKET: ARCTIC NEOPRENE8. ARMOR: BRONZE WIRE BRAID9. JACKET: ARCTIC NEOPRENE

C(OS)16,14,12,10PN

Page 13: Cables Industria Petrolera LS Cable

Offshore & Marine Cable 26

Power Distribution Cable0.6/1kV Control Cable

0.6/1kV Signal CableHigh Voltage Power Cable

Technical Data

0.6/1kV Control Cable- With Overall Shield

25

0.6/1kV C(OS)14PN, 0.6/1kV C(OS)14PNBS

No.

of coresConductor

size

AWG/MCM

Composition Conductor diameter

Nos/AWG mm inch

ConductorInsulationthickness

mm inch

Jacketthickness

mm

Sheaththickness

Unarmor

Overalldiameter

mm mm kg/kminch inchinch

Approx.Weight

Armor & Sheath

Overalldiameter

mm kg/kminch

Approx.Weight

2

3

4

5

6

7

10

12

14

16

19

20

24

30

37

44

60

91

0.6/1kV C(OS)18PN, 0.6/1kV C(OS)18PNBS

No.

of coresConductor

size

AWG/MCM

Composition Conductor diameter

Nos/AWG mm inch

ConductorInsulationthickness

mm inch

Jacketthickness

mm

Sheaththickness

Unarmor

Overalldiameter

mm mm kg/kminch inchinch

Approx.Weight

Armor & Sheath

Overalldiameter

mm kg/kminch

Approx.Weight

2

3

4

5

6

7

8

10

12

14

16

18

20

22

24

37

44

60

91

0.6/1kV C(OS)16PN, 0.6/1kV C(OS)16PNBS

No.

of coresConductor

size

AWG/MCM

Composition Conductor diameter

Nos/AWG mm inch

ConductorInsulationthickness

mm inch

Jacketthickness

mm

Sheaththickness

Unarmor

Overalldiameter

mm mm kg/kminch inchinch

Approx.Weight

Armor & Sheath

Overalldiameter

mm kg/kminch

Approx.Weight

2

3

4

5

6

7

8

10

12

14

16

18

20

22

24

37

44

60

91

0.6/1kV C(OS)20PN, 0.6/1kV C(OS)20PNBS

No.

of coresConductor

size

AWG/MCM

Composition Conductor diameter

Nos/AWG mm inch

ConductorInsulationthickness

mm inch

Jacketthickness

mm

Sheaththickness

Unarmor

Overalldiameter

mm mm kg/kminch inchinch

Approx.Weight

Armor & Sheath

Overalldiameter

mm kg/kminch

Approx.Weight

2

3

4

5

6

7

8

10

12

14

16

18

20

22

24

37

44

60

91

Page 14: Cables Industria Petrolera LS Cable

Offshore & Marine Cable 28

Power Distribution Cable0.6/1kV Control Cable

0.6/1kV Signal CableHigh Voltage Power Cable

Technical Data

0.6/1kV Control Cable- With Overall Braid Shield

27

0.6/1kV Control Cable - With Overall Braid Shield

Cable Contruction

0.6/1kV C(OBS)14PN, 0.6/1kV C(OBS)14PNBS

Applied Standards & FeaturesIEEE 1580(2001)IEEE 45(2002)UL 1309 / CSA C 22.2 No.245(1995)

100 (IEEE 1580 TYPE P)110 (UL 1309 / CSA C 22.2 No.245)FLEXEN 125 (UL 758 125)

Standards

Rating

Flame retardant : IEC 60332-3-22 CAT.A / IEEE 1202Cold resistant : CSA C 22.2 No.38(at -40 )Drilling Mud Resistant(Water & oil based Mud) : NEK 606(2004) & IEC 60092-350 Ed. 3.0(2008)Crush & Impact resistant : UL 1569 & UL 2227Excellent resistance to oil, abrasion, petrochemical fluids, moisture & sunlight.Low smoke version available (Type LSX, LSE, TPO & L)Superior flexibility

Feature

No.

of coresConductor

size

AWG/MCM

Composition Conductor diameter

Nos/AWG mm inch

ConductorInsulationthickness

mm inch

Jacketthickness

mm

Sheaththickness

Unarmor

Overalldiameter

mm mm kg/kminch inchinch

Approx.Weight

Armor & Sheath

Overalldiameter

mm kg/kminch

Approx.Weight

2

3

4

5

6

7

10

12

14

16

19

20

24

30

37

44

60

91

0.6/1kV C(OBS)16PN, 0.6/1kV C(OBS)16PNBS

No.

of coresConductor

size

AWG/MCM

Composition Conductor diameter

Nos/AWG mm inch

ConductorInsulationthickness

mm inch

Jacketthickness

mm

Sheaththickness

Unarmor

Overalldiameter

mm mm kg/kminch inchinch

Approx.Weight

Armor & Sheath

Overalldiameter

mm kg/kminch

Approx.Weight

2

3

4

5

6

7

8

10

12

14

16

18

20

22

24

37

44

60

91

Cable Designation / 0.6/1kV0.6/1kV C(OBS)14PN, 0.6/1kV C(OBS)14PNBS0.6/1kV C(OBS)16PN, 0.6/1kV C(OBS)16PNBS0.6/1kV C(OBS)18PN, 0.6/1kV C(OBS)18PNBS0.6/1kV C(OBS)20PN, 0.6/1kV C(OBS)20PNBS

Application Suitable for use in commercial marine applications, MODU's & PlatformOnshore and offshore drilling platformsFPSO, etc.

1. CONDUCTOR : TINNED ANNEALED ROPE-LAY STRANDED COPPER*For fire resisting cables, FS-type, mica tape shall be applied over the conductor as a fire proof layer

2. SEPARATOR TAPE (if necessary)3. INSULATION(TYPE P ACCORDING TO IEEE 1580)4. FILLER5. SHIELDING: TINNED COPPER WIRE BRAID6. JACKET: ARCTIC NEOPRENE7. ARMOR: BRONZE WIRE BRAID8. JACKET: ARCTIC NEOPRENE C(OS)16,14.12,10PN

Page 15: Cables Industria Petrolera LS Cable

0.6/1kV Control Cable- With Overall Braid Shield

29

0.6/1kV C(OBS)18PN, 0.6/1kV C(OBS)18PNBS

No.

of coresConductor

size

AWG/MCM

Composition Conductor diameter

Nos/AWG mm inch

ConductorInsulationthickness

mm inch

Jacketthickness

mm

Sheaththickness

Unarmor

Overalldiameter

mm mm kg/kminch inchinch

Approx.Weight

Armor & Sheath

Overalldiameter

mm kg/kminch

Approx.Weight

2

3

4

5

6

7

8

10

12

14

16

18

20

22

24

37

44

60

91

0.6/1kV C(OBS)20PN, 0.6/1kV C(OBS)20PNBS

No.

of coresConductor

size

AWG/MCM

Composition Conductor diameter

Nos/AWG mm inch

ConductorInsulationthickness

mm inch

Jacketthickness

mm

Sheaththickness

Unarmor

Overalldiameter

mm mm kg/kminch inchinch

Approx.Weight

Armor & Sheath

Overalldiameter

mm kg/kminch

Approx.Weight

2

3

4

5

6

7

8

10

12

14

16

18

20

22

24

37

44

60

91

0.6/1kV Signal Cable0.6/1kV Signal Cable - Overall Braid Shield0.6/1kV Signal Cable - Overall Shield

0.6/1kV Signal Cable - Individual Shield0.6/1kV Signal Cable - Individual & Overall Shield

Page 16: Cables Industria Petrolera LS Cable

Offshore & Marine Cable 32

Power Distribution Cable0.6/1kV Control Cable

0.6/1kV Signal CableHigh Voltage Power Cable

Technical Data

0.6/1kV Signal Cable- With Overall Shield

31

0.6/1kV Signal Cable - With Overall Shield

Cable Contruction1. CONDUCTOR : TINNED ANNEALED ROPE-LAY STRANDED COPPER2. SEPARATOR TAPE (if necessary)3. INSULATION(TYPE P ACCORDING TO IEEE 1580)4. FILLER5. BINDER TAPE6. DRAIN WIRE7. SHIELDING : ALUMINUM POLYESTER TAPE8. JACKET : ARCTIC NEOPRENE9. ARMOR : BRONZE WIRE BRAID

*Suitable tape may be applied over/under braid armor10. JACKET : ARCTIC NEOPRENE

TP(OS)14,16,18PNBS

0.6/1kV TP(OS)14PN, 0.6/1kV TP(OS)14PNBS

Applied Standards & FeaturesIEEE 1580(2001)IEEE 45(2002)UL 1309 / CSA C 22.2 No.245(1995)

100 (IEEE 1580 TYPE P)110 (UL 1309 / CSA C 22.2 No.245)FLEXEN 125 (UL 758 125)

Standards

Rating

Flame retardant : IEC 60332-3-22 CAT.A / IEEE 1202Cold resistant : CSA C 22.2 No.38(at -40 )Drilling Mud Resistant(Water & oil based Mud) : NEK 606(2004) & IEC 60092-350 Ed. 3.0(2008)Crush & Impact resistant : UL 1569 & UL 2227Excellent resistance to oil, abrasion, petrochemical fluids, moisture & sunlight.Low smoke version available (Type LSX, LSE, TPO & L)Superior flexibility

Feature

No.

of PairsConductor

size

AWG/MCM

Composition Conductor diameter

Nos/AWG mm inch

ConductorInsulationthickness

mm inch

Jacketthickness

mm

Sheaththickness

Unarmor

Overalldiameter

mm mm kg/kminch inchinch

Approx.Weight

Armor & Sheath

Overalldiameter

mm kg/kminch

Approx.Weight

1

2

3

4

5

6

7

8

9

10

12

14

16

24

0.6/1kV TP(OS)16PN, 0.6/1kV TP(OS)16PNBS

No.

of pairsConductor

size

AWG/MCM

Composition Conductor diameter

Nos/AWG mm inch

ConductorInsulationthickness

mm inch

Jacketthickness

mm

Sheaththickness

Unarmor

Overalldiameter

mm mm kg/kminch inchinch

Approx.Weight

Armor & Sheath

Overalldiameter

mm kg/kminch

Approx.Weight

1

2

3

4

5

6

7

8

9

10

12

14

16

24

Cable Designation / 0.6/1kV0.6/1kV TP(OS)14PN, 0.6/1kV TP(OS)14PNBS0.6/1kV TP(OS)16PN, 0.6/1kV TP(OS)16PNBS0.6/1kV TP(OS)18PN, 0.6/1kV TP(OS)18PNBS0.6/1kV TP(OS)20PN, 0.6/1kV TP(OS)20PNBS0.6/1kV TP(OS)22PN, 0.6/1kV TP(OS)22PNBS0.6/1kV TT(OS)16PN, 0.6/1kV TT(OS)16PNBS 0.6/1kV TT(OS)18PN, 0.6/1kV TT(OS)18PNBS0.6/1kV TT(OS)20PN, 0.6/1kV TT(OS)20PNBS

Application Suitable for use in commercial marine applications, MODU's & PlatformOnshore and offshore drilling platformsFPSO, etc.

Page 17: Cables Industria Petrolera LS Cable

Offshore & Marine Cable 34

Power Distribution Cable0.6/1kV Control Cable

0.6/1kV Signal CableHigh Voltage Power Cable

Technical Data

0.6/1kV Signal Cable- With Overall Shield

33

0.6/1kV TP(OS)18PN, 0.6/1kV TP(OS)18PNBS

No.

of pairsConductor

size

AWG/MCM

Composition Conductor diameter

Nos/AWG mm inch

ConductorInsulationthickness

mm inch

Jacketthickness

mm

Sheaththickness

Unarmor

Overalldiameter

mm mm kg/kminch inchinch

Approx.Weight

Armor & Sheath

Overalldiameter

mm kg/kminch

Approx.Weight

1

2

3

4

5

6

7

8

9

10

12

14

16

24

0.6/1kV TP(OS)20PN, 0.6/1kV TP(OS)20PNBS

No.

of pairsConductor

size

AWG/MCM

Composition Conductor diameter

Nos/AWG mm inch

ConductorInsulationthickness

mm inch

Jacketthickness

mm

Sheaththickness

Unarmor

Overalldiameter

mm mm kg/kminch inchinch

Approx.Weight

Armor & Sheath

Overalldiameter

mm kg/kminch

Approx.Weight

1

2

3

4

5

6

7

8

9

10

12

14

16

24

0.6/1kV TP(OS)22PN, 0.6/1kV TP(OS)22PNBS

No.

of pairsConductor

size

AWG/MCM

Composition Conductor diameter

Nos/AWG mm inch

ConductorInsulationthickness

mm inch

Jacketthickness

mm

Sheaththickness

Unarmor

Overalldiameter

mm mm kg/kminch inchinch

Approx.Weight

Armor & Sheath

Overalldiameter

mm kg/kminch

Approx.Weight

1

2

3

4

5

6

7

8

9

10

12

14

16

24

0.6/1KV TT(OS)16PN, 0.6/1KV TT(OS)16PNBS

No.

of pairsConductor

size

AWG/MCM

Composition Conductor diameter

Nos/AWG mm inch

ConductorInsulationthickness

mm inch

Jacketthickness

mm

Sheaththickness

Unarmor

Overalldiameter

mm mm kg/kminch inchinch

Approx.Weight

Armor & Sheath

Overalldiameter

mm kg/kminch

Approx.Weight

1

2

3

4

5

6

7

8

9

10

12

14

16

Page 18: Cables Industria Petrolera LS Cable

0.6/1kV Signal Cable - With Overall Braid Shield Pair Twisted

Cable Contruction1. CONDUCTOR : TINNED ANNEALED ROPE-LAY STRANDED COPPER2. SEPARATOR TAPE (if necessary)3. INSULATION(TYPE P ACCORDING TO IEEE 1580)4. FILLER5. BINDER TAPE6. SHIELDING : TINNED COPPER BRAID7. JACKET : ARCTIC NEOPRENE8. ARMOR : BRONZE WIRE BRAID

*Suitable tape may be applied over/under braid armor9. JACKET : ARCTIC NEOPRENE

TP(OBS)14,16,18NBS

Applied Standards & FeaturesIEEE 1580(2001)IEEE 45(2002)UL 1309 / CSA C 22.2 No.245(1995)

100 (IEEE 1580 TYPE P)110 (UL 1309 / CSA C 22.2 No.245)FLEXEN 125 (UL 758 125)

Standards

Rating

Flame retardant : IEC 60332-3-22 CAT.A / IEEE 1202Cold resistant : CSA C 22.2 No.38(at -40 )Drilling Mud Resistant(Water & oil based Mud) : NEK 606(2004) & IEC 60092-350 Ed. 3.0(2008)Crush & Impact resistant : UL 1569 & UL 2227Excellent resistance to oil, abrasion, petrochemical fluids, moisture & sunlight.Low smoke version available (Type LSX, LSE, TPO & L)Superior flexibility

Feature

Cable Designation / 0.6/1kV0.6/1kV TP(OBS)16PN, 0.6/1kV TP(OBS)16PNBS0.6/1kV TP(OBS)18PN, 0.6/1kV TP(OBS)18PNBS0.6/1kV TP(OBS)20PN, 0.6/1kV TP(OBS)20PNBS

Application Suitable for use in commercial marine applications, MODU's & PlatformOnshore and offshore drilling platformsFPSO, etc.

Offshore & Marine Cable 36

Power Distribution Cable0.6/1kV Control Cable

0.6/1kV Signal CableHigh Voltage Power Cable

Technical Data

0.6/1kV Signal Cable- With Overall Shield

0.6/1kV Signal Cable - With Overall Braid Shield Pair Twisted

35

0.6/1kV TT(OS)18PN, 0.6/1kV TT(OS)18PNBS

No.

of triadsConductor

size

AWG/MCM

Composition Conductor diameter

Nos/AWG mm inch

ConductorInsulationthickness

mm inch

Jacketthickness

mm

Sheaththickness

Unarmor

Overalldiameter

mm mm kg/kminch inchinch

Approx.Weight

Armor & Sheath

Overalldiameter

mm kg/kminch

Approx.Weight

1

2

3

4

5

6

7

8

9

10

12

14

16

0.6/1kV TT(OS)20PN, 0.6/1kV TT(OS)20PNBS

No.

of triadsConductor

size

AWG/MCM

Composition Conductor diameter

Nos/AWG mm inch

ConductorInsulationthickness

mm inch

Jacketthickness

mm

Sheaththickness

Unarmor

Overalldiameter

mm mm kg/kminch inchinch

Approx.Weight

Armor & Sheath

Overalldiameter

mm kg/kminch

Approx.Weight

1

2

3

4

5

6

7

8

9

10

12

14

16

Page 19: Cables Industria Petrolera LS Cable

Offshore & Marine Cable 38

Power Distribution Cable0.6/1kV Control Cable

0.6/1kV Signal CableHigh Voltage Power Cable

Technical Data

0.6/1kV Signal Cable- With Overall Braid Shield Pair Twisted

37

0.6/1kV TP(OBS)16PN, 0.6/1kV TP(OBS)16PNBS

No.

of pairsConductor

size

AWG/MCM

Composition Conductor diameter

Nos/AWG mm inch

ConductorInsulationthickness

mm inch

Jacketthickness

mm

Sheaththickness

Unarmor

Overalldiameter

mm mm kg/kminch inchinch

Approx.Weight

Armor & Sheath

Overalldiameter

mm kg/kminch

Approx.Weight

1

2

3

4

5

6

7

8

9

10

12

14

16

24

0.6/1kV TP(OBS)20PN, 0.6/1kV TP(OBS)20PNBS

No.

of pairsConductor

size

AWG/MCM

Composition Conductor diameter

Nos/AWG mm inch

ConductorInsulationthickness

mm inch

Jacketthickness

mm

Sheaththickness

Unarmor

Overalldiameter

mm mm kg/kminch inchinch

Approx.Weight

Armor & Sheath

Overalldiameter

mm kg/kminch

Approx.Weight

1

2

3

4

5

6

7

8

9

10

12

14

16

24

0.6/1kV TP(OBS)18PN, 0.6/1kV TP(OBS)18PNBS

No.

of pairsConductor

size

AWG/MCM

Composition Conductor diameter

Nos/AWG mm inch

ConductorInsulationthickness

mm inch

Jacketthickness

mm

Sheaththickness

Unarmor

Overalldiameter

mm mm kg/kminch inchinch

Approx.Weight

Armor & Sheath

Overalldiameter

mm kg/kminch

Approx.Weight

1

2

3

4

5

6

7

8

9

10

12

14

16

24

Page 20: Cables Industria Petrolera LS Cable

Offshore & Marine Cable 40

Power Distribution Cable0.6/1kV Control Cable

0.6/1kV Signal CableHigh Voltage Power Cable

Technical Data

0.6/1kV Signal Cable - With Individual Shield Pair Twisted

39

0.6/1kV Signal Cable - With Individual Shield Pair Twisted

Cable Contruction1. CONDUCTOR : TINNED ANNEALED ROPE-LAY STRANDED COPPER2. SEPARATOR TAPE (if necessary)3. INSULATION(TYPE P ACCORDING TO IEEE 1580)4. BINDER TAPE5. DRAIN WIRE6. SHIELDING : ALUMINUM POLYESTER TAPE7. FILLER8. JACKET : ARCTIC NEOPRENE9. ARMOR : BRONZE WIRE BRAID

*Suitable tape may be applied over/under braid armor10. JACKET : ARCTIC NEOPRENE

TP(I/S)16PNBS

Applied Standards & FeaturesIEEE 1580(2001)IEEE 45(2002)UL 1309 / CSA C 22.2 No.245(1995)

100 (IEEE 1580 TYPE P)110 (UL 1309 / CSA C 22.2 No.245)FLEXEN 125 (UL 758 125)

Standards

Rating

Flame retardant : IEC 60332-3-22 CAT.A / IEEE 1202Cold resistant : CSA C 22.2 No.38(at -40 )Drilling Mud Resistant(Water & oil based Mud) : NEK 606(2004) & IEC 60092-350 Ed. 3.0(2008)Crush & Impact resistant : UL 1569 & UL 2227Excellent resistance to oil, abrasion, petrochemical fluids, moisture & sunlight.Low smoke version available (Type LSX, LSE, TPO & L)Superior flexibility

Feature

Cable Designation / 0.6/1kkV0.6/1kV TP(I/S)14PN, 0.6/1kV TP(I/S)14PNBS0.6/1kV TP(I/S)16PN, 0.6/1kV TP(I/S)16PNBS0.6/1kV TP(I/S)18PN, 0.6/1kV TP(I/S)18PNBS0.6/1kV TP(I/S)20PN, 0.6/1kV TP(I/S)20PNBS0.6/1kV TT(I/S)16PN, 0.6/1kV TT(I/S)16PNBS0.6/1kV TT(I/S)18PN, 0.6/1kV TT(I/S)18PNBS0.6/1kV TT(I/S)20PN, 0.6/1kV TT(I/S)20PNBS

Application Suitable for use in commercial marine applications, MODU's & PlatformOnshore and offshore drilling platformsFPSO, etc.

0.6/1kV TP(I/S)14PN, 0.6/1kV TP(I/S)14PNBS

No.

of pairsConductor

size

AWG/MCM

Composition Conductor diameter

Nos/AWG mm inch

ConductorInsulationthickness

mm inch

Jacketthickness

mm

Sheaththickness

Unarmor

Overalldiameter

mm mm kg/kminch inchinch

Approx.Weight

Armor & Sheath

Overalldiameter

mm kg/kminch

Approx.Weight

2

3

4

5

6

7

8

9

10

12

14

16

18

24

0.6/1kV TP(I/S)16PN, 0.6/1kV TP(I/S)16PNBS

No.

of pairsConductor

size

AWG/MCM

Composition Conductor diameter

Nos/AWG mm inch

ConductorInsulationthickness

mm inch

Jacketthickness

mm

Sheaththickness

Unarmor

Overalldiameter

mm mm kg/kminch inchinch

Approx.Weight

Armor & Sheath

Overalldiameter

mm kg/kminch

Approx.Weight

2

3

4

5

6

7

8

9

10

12

14

16

18

24

Page 21: Cables Industria Petrolera LS Cable

Offshore & Marine Cable 42

Power Distribution Cable0.6/1kV Control Cable

0.6/1kV Signal CableHigh Voltage Power Cable

Technical Data

0.6/1kV Signal Cable - With Individual Shield Pair Twisted

41

0.6/1kV TP(I/S)18PN, 0.6/1kV TP(I/S)18PNBS

No.

of pairsConductor

size

AWG/MCM

Composition Conductor diameter

Nos/AWG mm inch

ConductorInsulationthickness

mm inch

Jacketthickness

mm

Sheaththickness

Unarmor

Overalldiameter

mm mm kg/kminch inchinch

Approx.Weight

Armor & Sheath

Overalldiameter

mm kg/kminch

Approx.Weight

2

3

4

5

6

7

8

9

10

12

14

16

18

24

0.6/1kV TP(I/S)20PN, 0.6/1kV TP(I/S)20PNBS

No.

of pairsConductor

size

AWG/MCM

Composition Conductor diameter

Nos/AWG mm inch

ConductorInsulationthickness

mm inch

Jacketthickness

mm

Sheaththickness

Unarmor

Overalldiameter

mm mm kg/kminch inchinch

Approx.Weight

Armor & Sheath

Overalldiameter

mm kg/kminch

Approx.Weight

2

3

4

5

6

7

8

9

10

12

14

16

18

24

0.6/1kV TT(I/S)16PN, 0.6/1kV TT(I/S)16PNBS

No.

of pairsConductor

size

AWG/MCM

Composition Conductor diameter

Nos/AWG mm inch

ConductorInsulationthickness

mm inch

Jacketthickness

mm

Sheaththickness

Unarmor

Overalldiameter

mm mm kg/kminch inchinch

Approx.Weight

Armor & Sheath

Overalldiameter

mm kg/kminch

Approx.Weight

2

3

4

5

6

7

8

9

10

12

14

16

0.6/1KV TT(I/S)18PN, 0.6/1KV TT(I/S)18PNBS

No.

of pairsConductor

size

AWG/MCM

Composition Conductor diameter

Nos/AWG mm inch

ConductorInsulationthickness

mm inch

Jacketthickness

mm

Sheaththickness

Unarmor

Overalldiameter

mm mm kg/kminch inchinch

Approx.Weight

Armor & Sheath

Overalldiameter

mm kg/kminch

Approx.Weight

2

3

4

5

6

7

8

9

10

12

14

16

Page 22: Cables Industria Petrolera LS Cable

0.6/1kV Signal Cable - With Individual & Overall Shield

Cable Contruction1. CONDUCTOR : TINNED ANNEALED ROPE-LAY STRANDED COPPER2. SEPARATOR TAPE (if necessary)3. INSULATION(TYPE P ACCORDING TO IEEE 1580)4. BINDER TAPE5. DRAIN WIRE6. SHIELDING : ALUMINUM POLYSTER TAPE7. FILLER8. JACKET : ARCTIC NEOPRENE9. ARMOR : BRONZE WIRE BRAID

*Suitable tape may be applied over/under braid armor10. JACKET : ARCTIC NEOPRENE

TP(I/S-OS)16,18,20PNBS

Applied Standards & FeaturesIEEE 1580(2001)IEEE 45(2002)UL 1309 / CSA C 22.2 No.245(1995)

100 (IEEE 1580 TYPE P)110 (UL 1309 / CSA C 22.2 No.245)FLEXEN 125 (UL 758 125)

Standards

Rating

Flame retardant : IEC 60332-3-22 CAT.A / IEEE 1202Cold resistant : CSA C 22.2 No.38(at -40 )Drilling Mud Resistant(Water & oil based Mud) : NEK 606(2004) & IEC 60092-350 Ed. 3.0(2008)Crush & Impact resistant : UL 1569 & UL 2227Excellent resistance to oil, abrasion, petrochemical fluids, moisture & sunlight.Low smoke version available (Type LSX, LSE, TPO & L)Superior flexibility

Feature

Cable Designation / 0.6/1kV0.6/1kV TP(I/S-OS)14PN, 0.6/1kV TP(I/S-OS)14PNBS0.6/1kV TP(I/S-OS)16PN, 0.6/1kV TP(I/S-OS)16PNBS0.6/1kV TP(I/S-OS)18PN, 0.6/1kV TP(I/S-OS)18PNBS0.6/1kV TP(I/S-OS)20PN, 0.6/1kV TP(I/S-OS)20PNBS0.6/1kV TT(I/S-OS)16PN, 0.6/1kV TT(I/S-OS)16PNBS0.6/1kV TT(I/S-OS)18PN, 0.6/1kV TT(I/S-OS)18PNBS0.6/1kV TT(I/S-OS)20PN, 0.6/1kV TT(I/S-OS)20PNBS

Application Suitable for use in commercial marine applications, MODU's & PlatformOnshore and offshore drilling platformsFPSO, etc.

Offshore & Marine Cable 44

Power Distribution Cable0.6/1kV Control Cable

0.6/1kV Signal CableHigh Voltage Power Cable

Technical Data

0.6/1kV Signal Cable 0.6/1kV Signal Cable- With Individual Shield Pair Twisted - With Individual & Overall Shield

43

0.6/1kV TT(I/S)20PN, 0.6/1kV TT(I/S)20PNBS

No.

of pairsConductor

size

AWG/MCM

Composition Conductor diameter

Nos/AWG mm inch

ConductorInsulationthickness

mm inch

Jacketthickness

mm

Sheaththickness

Unarmor

Overalldiameter

mm mm kg/kminch inchinch

Approx.Weight

Armor & Sheath

Overalldiameter

mm kg/kminch

Approx.Weight

2

3

4

5

6

7

8

9

10

12

14

16

Page 23: Cables Industria Petrolera LS Cable

Offshore & Marine Cable 46

Power Distribution Cable0.6/1kV Control Cable

0.6/1kV Signal CableHigh Voltage Power Cable

Technical Data

0.6/1kV Signal Cable- With Individual & Overall Shield

45

0.6/1kV TP(I/S-OS)14PN, 0.6/1kV TP(I/S-OS)14PNBS

No.

of pairsConductor

size

AWG/MCM

Composition Conductor diameter

Nos/AWG mm inch

ConductorInsulationthickness

mm inch

Jacketthickness

mm

Sheaththickness

Unarmor

Overalldiameter

mm mm kg/kminch inchinch

Approx.Weight

Armor & Sheath

Overalldiameter

mm kg/kminch

Approx.Weight

2

3

4

5

6

7

8

9

10

12

14

16

18

24

0.6/1kV TP(I/S-OS)16PN, 0.6/1kV TP(I/S-OS)16PNBS

No.

of pairsConductor

size

AWG/MCM

Composition Conductor diameter

Nos/AWG mm inch

ConductorInsulationthickness

mm inch

Jacketthickness

mm

Sheaththickness

Unarmor

Overalldiameter

mm mm kg/kminch inchinch

Approx.Weight

Armor & Sheath

Overalldiameter

mm kg/kminch

Approx.Weight

2

3

4

5

6

7

8

9

10

12

14

16

18

24

0.6/1kV TP(I/S-OS)18PN, 0.6/1kV TP(I/S-OS)18PNBS

No.

of pairsConductor

size

AWG/MCM

Composition Conductor diameter

Nos/AWG mm inch

ConductorInsulationthickness

mm inch

Jacketthickness

mm

Sheaththickness

Unarmor

Overalldiameter

mm mm kg/kminch inchinch

Approx.Weight

Armor & Sheath

Overalldiameter

mm kg/kminch

Approx.Weight

2

3

4

5

6

7

8

9

10

12

14

16

18

24

0.6/1kV TP(I/S-OS)20PN, 0.6/1kV TP(I/S-OS)20PNBS

No.

of pairsConductor

size

AWG/MCM

Composition Conductor diameter

Nos/AWG mm inch

ConductorInsulationthickness

mm inch

Jacketthickness

mm

Sheaththickness

Unarmor

Overalldiameter

mm mm kg/kminch inchinch

Approx.Weight

Armor & Sheath

Overalldiameter

mm kg/kminch

Approx.Weight

2

3

4

5

6

7

8

9

10

12

14

16

18

24

Page 24: Cables Industria Petrolera LS Cable

0.6/1kV Signal Cable- With Individual & Overall Shield

47

0.6/1kV TT(I/S-OS)16PN, 0.6/1kV TT(I/S-OS)16PNBS

No.

of pairsConductor

size

AWG/MCM

Composition Conductor diameter

Nos/AWG mm inch

ConductorInsulationthickness

mm inch

Jacketthickness

mm

Sheaththickness

Unarmor

Overalldiameter

mm mm kg/kminch inchinch

Approx.Weight

Armor & Sheath

Overalldiameter

mm kg/kminch

Approx.Weight

2

3

4

5

6

7

8

9

10

12

14

16

0.6/1kV TT(I/S-OS)20PN, 0.6/1kV TT(I/S-OS)20PNBS

No.

of pairsConductor

size

AWG/MCM

Composition Conductor diameter

Nos/AWG mm inch

ConductorInsulationthickness

mm inch

Jacketthickness

mm

Sheaththickness

Unarmor

Overalldiameter

mm mm kg/kminch inchinch

Approx.Weight

Armor & Sheath

Overalldiameter

mm kg/kminch

Approx.Weight

2

3

4

5

6

7

8

9

10

12

14

16

0.6/1kV TT(I/S-OS)18PN, 0.6/1kV TT(I/S-OS)18PNBS

No.

of pairsConductor

size

AWG/MCM

Composition Conductor diameter

Nos/AWG mm inch

ConductorInsulationthickness

mm inch

Jacketthickness

mm

Sheaththickness

Unarmor

Overalldiameter

mm mm kg/kminch inchinch

Approx.Weight

Armor & Sheath

Overalldiameter

mm kg/kminch

Approx.Weight

2

3

4

5

6

7

8

9

10

12

14

16

High Voltage Power CableHigh Voltage Power Cable- 5kV, 8kV, 15kV

Page 25: Cables Industria Petrolera LS Cable

High Voltage Power Cable - 5kV, 8kv, 15kV

Cable Contruction1. CONDUCTOR : TINNED ANNEALED ROPE-LAY STRANDED COPPER2. CONDUCTOR SHIELDING : SEMI-CONDUCTIING TAPE AND COMPOUND3. INSULATION : ERR(ETHYLENE PROPYLENE RUBBER)4. INSULATION SHIELD(NON-METALLIC MATERIAL : SEMI-CONDUCTING TAPE/COMPOUND)5. INSULATION SHIELD(METAILIC) : TINNED COPPER WIRE BRAID6.JACKET: ARCTIC NEOPRENE

5kV/8kV/15kV TENBSApplied Standards & FeaturesIEEE 1580(2001)IEEE 45(2002)ICEA S 93-639(20000)UL 1072(2001)UL 1309 / CSA C 22.2 No.245(1995)

90 (IEEE 1580 TYPE E)105 (UL 1309 / CSA C 22.2 No.245)

Standards

Rating

Flame retardant : IEC 60332-3-22 CAT.A / IEEE 1202Cold resistant : CSA C 22.2 No.38(at -40 )Drilling Mud Resistant(Water & oil based Mud) : NEK 606(2004) & IEC 60092-350 Ed. 3.0(2008)"Crush & Impact resistant : UL 1569 & UL 2227Excellent resistance to oil, abrasion, petrochemical fluids, moisture & sunlight.Low smoke version available (Type LSX, LSE, TPO & L)Superior flexibility

Feature

Cable Designation / 5kV,8kV,15kV5kV SEN(BS), 5kV SEL(BS) (100%, 133% Insulation level)5kV TEN(BS), 5kV TEL(BS) (100%, 133% Insulation level)8kV SEN(BS), 8kV SEL(BS)) (100%, 133% Insulation level)8kV TEN(BS), 8kV TEL(BS)) (100%, 133% Insulation level)15kV SEN(BS), 15kV SEL(BS)) (100%, 133% Insulation level)15kV TEN(BS), 15kV TEL(BS) (100%, 133% Insulation level)

Application Suitable for use in commercial marine applications, MODU's & PlatformOnshore and offshore drilling platformsFPSO, etc.

Offshore & Marine Cable 50

Power Distribution Cable0.6/1kV Control Cable

0.6/1kV Signal CableHigh Voltage Power Cable

Technical Data

High Voltage Power Cable- 5kV, 8kV, 15kV

49

5kV SEN(BS), 5kV SEL(BS) (100% Insulation level)

No.

of coresConductor

size

AWG/MCM

Composition Conductordiameter

Nos/AWG mm inch

Insulationthickness

mm inch

Jacketthickness

Sheaththickness

mm

Impedance(Phase-Neutral)

/km /1000ftinch mm inch

Conductor

Overalldiameter

mm inch

ApproxWeight

kg/km

Unarmor

Overalldiameter

mm inch

ApproxWeight

kg/km

Armor & Sheath

Inductance

/km /1000ft

Reactance

/km /1000ft

Capacitance

/km /1000ft

1

5kV SEN(BS), 5kV SEL(BS) (133% Insulation level)

No.

of coresConductor

size

AWG/MCM

Composition Conductordiameter

Nos/AWG mm inch

Insulationthickness

mm inch

Jacketthickness

Sheaththickness

mm

Impedance(Phase-Neutral)

/km /1000ftinch mm inch

Conductor

Overalldiameter

mm inch

ApproxWeight

kg/km

Unarmor

Overalldiameter

mm inch

ApproxWeight

kg/km

Armor & Sheath

Inductance

/km /1000ft

Reactance

/km /1000ft

Capacitance

/km /1000ft

1

Page 26: Cables Industria Petrolera LS Cable

Offshore & Marine Cable 52

Power Distribution Cable0.6/1kV Control Cable

0.6/1kV Signal CableHigh Voltage Power Cable

Technical Data

High Voltage Power Cable- 5kV, 8kV, 15kV

51

5kV TEN(BS), 5kV TEL(BS) (100% Insulation level)

No.

of coresConductor

size

AWG/MCM

Composition Conductordiameter

Nos/AWG mm inch

Insulationthickness

mm inch

Jacketthickness

Sheaththickness

mm

Impedance(Phase-Neutral)

/km /1000ftinch mm inch

Conductor

Overalldiameter

mm inch

ApproxWeight

kg/km

Unarmor

Overalldiameter

mm inch

ApproxWeight

kg/km

Armor & Sheath

Inductance

/km /1000ft

Reactance

/km /1000ft

Capacitance

/km /1000ft

3

5kV TEN(BS), 5kV TEL(BS) (133% Insulation level)

No.

of coresConductor

size

AWG/MCM

Composition Conductordiameter

Nos/AWG mm inch

Insulationthickness

mm inch

Jacketthickness

Sheaththickness

mm

Impedance(Phase-Neutral)

/km /1000ftinch mm inch

Conductor

Overalldiameter

mm inch

ApproxWeight

kg/km

Unarmor

Overalldiameter

mm inch

ApproxWeight

kg/km

Armor & Sheath

Inductance

/km /1000ft

Reactance

/km /1000ft

Capacitance

/km /1000ft

3

8kV SEN(BS), 8kV SEL(BS) (100% Insulation level)

No.

of coresConductor

size

AWG/MCM

Composition Conductordiameter

Nos/AWG mm inch

Insulationthickness

mm inch

Jacketthickness

Sheaththickness

mm

Impedance(Phase-Neutral)

/km /1000ftinch mm inch

Conductor

Overalldiameter

mm inch

ApproxWeight

kg/km

Unarmor

Overalldiameter

mm inch

ApproxWeight

kg/km

Armor & Sheath

Inductance

/km /1000ft

Reactance

/km /1000ft

Capacitance

/km /1000ft

1

8kV SEN(BS), 8kV SEL(BS) (133% Insulation level)

No.

of coresConductor

size

AWG/MCM

Composition Conductordiameter

Nos/AWG mm inch

Insulationthickness

mm inch

Jacketthickness

Sheaththickness

mm

Impedance(Phase-Neutral)

/km /1000ftinch mm inch

Conductor

Overalldiameter

mm inch

ApproxWeight

kg/km

Unarmor

Overalldiameter

mm inch

ApproxWeight

kg/km

Armor & Sheath

Inductance

/km /1000ft

Reactance

/km /1000ft

Capacitance

/km /1000ft

1

Page 27: Cables Industria Petrolera LS Cable

Offshore & Marine Cable 54

Power Distribution Cable0.6/1kV Control Cable

0.6/1kV Signal CableHigh Voltage Power Cable

Technical Data

High Voltage Power Cable- 5kV, 8kV, 15kV

53

8kV TEN(BS), 8kV TEL(BS) (100% Insulation level) 15kV SEN(BS), 15kV SEL(BS) (100% Insulation level)

No.

of coresConductor

size

AWG/MCM

Composition Conductordiameter

Nos/AWG mm inch

Insulationthickness

mm inch

Jacketthickness

Sheaththickness

mm

Impedance(Phase-Neutral)

/km /1000ftinch mm inch

Conductor

Overalldiameter

mm inch

ApproxWeight

kg/km

Unarmor

Overalldiameter

mm inch

ApproxWeight

kg/km

Armor & Sheath

Inductance

/km /1000ft

Reactance

/km /1000ft

Capacitance

/km /1000ft

5kV TEN(BS), 5kV TEL(BS) (133% Insulation level)

No.

of coresConductor

size

AWG/MCM

Composition Conductordiameter

Nos/AWG mm inch

Insulationthickness

mm inch

Jacketthickness

Sheaththickness

mm

Impedance(Phase-Neutral)

/km /1000ftinch mm inch

Conductor

Overalldiameter

mm inch

ApproxWeight

kg/km

Unarmor

Overalldiameter

mm inch

ApproxWeight

kg/km

Armor & Sheath

Inductance

/km /1000ft

Reactance

/km /1000ft

Capacitance

/km /1000ft

3

3

No.

of coresConductor

size

AWG/MCM

Composition Conductordiameter

Nos/AWG mm inch

Insulationthickness

mm inch

Jacketthickness

Sheaththickness

mm

Impedance(Phase-Neutral)

/km /1000ftinch mm inch

Conductor

Overalldiameter

mm inch

ApproxWeight

kg/km

Unarmor

Overalldiameter

mm inch

ApproxWeight

kg/km

Armor & Sheath

Inductance

/km /1000ft

Reactance

/km /1000ft

Capacitance

/km /1000ft

5kV TEN(BS), 5kV TEL(BS) (133% Insulation level)

No.

of coresConductor

size

AWG/MCM

Composition Conductordiameter

Nos/AWG mm inch

Insulationthickness

mm inch

Jacketthickness

Sheaththickness

mm

Impedance(Phase-Neutral)

/km /1000ftinch mm inch

Conductor

Overalldiameter

mm inch

ApproxWeight

kg/km

Unarmor

Overalldiameter

mm inch

ApproxWeight

kg/km

Armor & Sheath

Inductance

/km /1000ft

Reactance

/km /1000ft

Capacitance

/km /1000ft

1

1

Page 28: Cables Industria Petrolera LS Cable

High Voltage Power Cable- 5kV, 8kV, 15kV

55

15kV TEN(BS), 15kV TEL(BS) (100% Insulation level)

No.

of coresConductor

size

AWG/MCM

Composition Conductordiameter

Nos/AWG mm inch

Insulationthickness

mm inch

Jacketthickness

Sheaththickness

mm

Impedance(Phase-Neutral)

/km /1000ftinch mm inch

Conductor

Overalldiameter

mm inch

ApproxWeight

kg/km

Unarmor

Overalldiameter

mm inch

ApproxWeight

kg/km

Armor & Sheath

Inductance

/km /1000ft

Reactance

/km /1000ft

Capacitance

/km /1000ft

15kV TEN(BS), 15kV TEL(BS) (133% Insulation level)

No.

of coresConductor

size

AWG/MCM

Composition Conductordiameter

Nos/AWG mm inch

Insulationthickness

mm inch

Jacketthickness

Sheaththickness

mm

Impedance(Phase-Neutral)

/km /1000ftinch mm inch

Conductor

Overalldiameter

mm inch

ApproxWeight

kg/km

Unarmor

Overalldiameter

mm inch

ApproxWeight

kg/km

Armor & Sheath

Inductance

/km /1000ft

Reactance

/km /1000ft

Capacitance

/km /1000ft

3

3

Technical DataTechnical Data

Installation Information

Page 29: Cables Industria Petrolera LS Cable

Offshore & Marine Cable 58

Power Distribution Cable0.6/1kV Control Cable

0.6/1kV Signal CableHigh Voltage Power Cable

Technical Data

Technical Data

57

1. Construction and resistance of flexible stranded conductors

Note : The total number of wires should be as specified 1% providing that the maximum conductor diameter and conductor resistance dose notexceed the values indicated.

Conductorarea in

circular mils AWGor cmil Number of wires Individual strand

dia.(in)

Maxconductor

dia.(in)Ohmsper 1000ft at 25°C Ohms per 1000ft at 20°C Ohms per km at 20°C

mm2

Bare Coated Bare Coated Bare Coated

Nominal Stranding Maximum dc resistance

2. Min. Insulation Resistance & High-voltage AC Test Potentials 1) TYPE P (FLEXEN 125) Insulated Cables

Conductor Size Insulation resistance Insulation resistance Test potentials

AWG or KCM at 15.6°C [M -km] at 15.6°C [M -1000ft] [V]

Cable Voltage rating 0 - 2000V 600 -1000V 1001- 2000V

2) TYPE E Insulated Cables for 5kV - 15kV Shield Conductors

Conductor Size insulation resistance constant K Test potentials

AWG or KCM at 15.6°C [M -1000ft] [V]

Cable Voltage rating 5kV - 15kV 8kV5kV 15kV

Tolerance for maximum resistanceSingle conductor Rmax= value from the Table 1

Multiple conductor

One layer of conductors Rmax= value from the Table 1 x 1.02

More than one layer of conductors Rmax= value from the Table 1 x 1.03

Pairs or other precabled units Rmax= value from the Table 1 x 1.04

More than one layer Pairs or other precabled units Rmax= value from the Table 1 x 1.05

Page 30: Cables Industria Petrolera LS Cable

Offshore & Marine Cable 60

Power Distribution Cable0.6/1kV Control Cable

0.6/1kV Signal CableHigh Voltage Power Cable

Technical Data

Technical Data

59

3) AC Spark test Voltage

ConductorAWG or kcmil mm2

Cable Voltage rating 0-300 V 301-600/1000 V 1001/2000 V

* The test is carried out rated 0-2000V manufactured without shield or amor for single conductor cables.

3. Single banked, Maximum Current-Carrying Capacity1) Distribution,Control and Signal Cables(Type P @ 45°C ambient)

AWG or MCM mm2 Circular milsMaximum conductor temperature : 100°C

TYPE P

Conductor Area Single Core Two Core Three Core

2) Distribution, Control and Signal Cables(Type X110 @ 45°C ambient)

AWG or MCM mm2 Circular milsMaximum conductor temperature : 110°C

X110

Conductor Area Single Core Two Core Three Core

AC spark test voltage(kV)

Page 31: Cables Industria Petrolera LS Cable

Offshore & Marine Cable 62

Power Distribution Cable0.6/1kV Control Cable

0.6/1kV Signal CableHigh Voltage Power Cable

Technical Data

Technical Data

61

3) Medium-voltage power cable (Type E @ 45°C ambient)

AWG or MCM mm2 Circular milsMaximum conductor temperature : 90°C

Conductor Area

Up to 8kV shielded 8001-15000V shielded 15001-35000V shielded

Single conductor cable

4) Distribution, Control and Signal Cables(Number of conductors for ambient temperature)

Number of conductors Amapacity adjustment factors for more than 3 conductors in a cable with on load diversity. Percent of values in the above table for three-conductor as adjusted for ambient temperature, if necessary.

Ampacity adjustment factors for more than 3 conductors in a cable with no load diversity :Percent of values in the above table for three-conductor as adjusted for ambient temperature, if necessary

5) Correction factors for various cooling temperaturesAmbient Temperature

4. Short circuit current ratingsNominal crosssectional area

(AWG, MCM) Duration of short circuit in second

0.1 0.2 0.5 1.0

Short circuit currents(kA)

Page 32: Cables Industria Petrolera LS Cable

Offshore & Marine Cable 64

Power Distribution Cable0.6/1kV Control Cable

0.6/1kV Signal CableHigh Voltage Power Cable

Technical Data

Installation Information

63

5. Installation Recommendation1) Maximum ambient temperature

The use of TYPE P insulation type should be restricted to the 70°C(158°F) in shipboard spaces.

2) Radius of bends

Armored cables should not be bent to a radius of less than eight times the cable’s diameter.Unarmored cables may not be bent to a radius of less than six times the cable’s diameter.

3) Cable pulling-in force

Care should be taken to prevent damage to insulation or distortion of cable during installation.

Straight pulling forces should not exceed 0.008 times the tensile strength of the copper cross-sectional area when pulling on the conductors utilizingpulling eyes and bolts. When pulling with a basket-weave grip, maximum pulling tension(per grip) should not exceed 460kg(1000 Ib), or the valuecalculated above, whichever is greater.

The sidewall pressure should not exceed 450 kg/m(300 Ib/ft) of the inside radius of the bend.

Cables should not be pulled in freezing conditions. If it is necessary to pull in these conditions, cables should be stored at a temperature above10°C(50°F) for 24 prior to installation, if the cable has been previously stored in an area under 0°C(32°F)

Additional consideration should be given when installing low-smoke cables due to their possible lower tear strength and coefficient of friction.

4) Single-Conductor AC Cables

To avoid an undesirable inductive effect in ac installations, the following precautions should be observed:

a) Closed magnetic circuits around single-conductor ac cable should be avoided, and no magnetic material permitted between cables of differentphases of a circuit.

b) Single-conductor ac cable s should not be located closer than 76mm(3 in) from parallel magnetic material.

c) Single conductor ac cable should be supported on insulators. Armor, if used, should be grounded only at approximately the midpoint of the cable run.

d) Where single-conductor ac cables penetrate the bulkhead, conductors of each phase of the same circuit should pass through a common nonfer-rous bulkhead plate to prevent heating of the bulkhead.

e) Single-conductor cables in groups should be arranged to minimize their inductive effect. This may be accomplished by the transposition of cablesin groups of three (one each phase) to give the effect of triplexed cable. This transposition should be made at intervals of not over 15m(50ft) andneed not be made in cable runs of less than 30m(100ft).

5) Cable Continuty and Grounding

All cable should be continuous between terminations , however, splicing is permitted under certain conditions . For cable provided with armor, thearmor should be electrically continuous between terminations and should be grounded at each end (multiconductor cables only); except that for finalsubcircuits, the armor may be grounded at the supply end only.

6) Cable Locations

Cable installation should avoid spaces where excessive heat and gases may be encountered such as galleys, boiler rooms and pump rooms, andspaces where cables may be exposed to damage such as cargo spaces and exposed sides of deck houses. Cables should not be located in cargotanks, ballast tanks, fuel tanks, or water tanks except to supply equipment and instrumentation specifically designed for such locations and whosefunctions require it to be installed in the tank. Such equipment might include submerged cargo pumps and associated control devices, cargo moni-toring instrumentation, and underwater navigation systems.

Unless unavoidable, cables should not be located behind or embedded in structural heat insulation. Where cables are installed behind paneling, allconnections should be readily accessible, and the location of concealed connections should be readily accessible, and the location of concealedconnection boxes should be indicated. Cables should preferably not be run through refrigerated cargo spaces.

Cables should not be located in bilges.

7) Cable Protection

Cables should be adequately protected where exposed to mechanical damage. Cables should be secured against chafing or displacement due tovibration. Cables in bunkers, and where particularly liable to damage, such as locations in way of cargo ports, hatches, tank tops, and where passingthrough decks, should be protected by removable metal coverings, angle irons, or other equivalent means.

Where cables pass through insulation, they should be protected by a continuous pipe. For wiring entering refrigerated compartments, the pipeshould be of heat-insulating material (fiber or phenolic tubing) joined to the bulkhead-stuffing tube, or a section of such material should be insertedbetween the bulkhead-stuffing tube and the metallic pipe.

Where cables a re installed in pipes, the space factor (ratio of the sum of the crosss-sectional areas corresponding to the external diameter of thecables to the internal cross-sectional areas of the pipe) shall not be greater than 0.41, except for two cables, where the space factor shall not exceed0.31. Pipes shall be so arranged or designed or designed to prevent the accumulation of internal condensation.

D

r

Page 33: Cables Industria Petrolera LS Cable

Offshore & Marine Cable 66

Power Distribution Cable0.6/1kV Control Cable

0.6/1kV Signal CableHigh Voltage Power Cable

Technical Data

Installation Information

65

1) Type P Crosslinked Polyolefin InsulationDescription Unit Requirements

3) Mechanical Properties of EPR compound (Insulation) *Application Standard : UL 1072

Description Unit Requirements

4) Mechanical Properties of Polychloroprene (Neoprene) compound (Sheath) * Application Standard :

UL 1072 Description Unit Requirements

2) Type N Arctic Neoprene SheathDescription Unit Requirements

6. Meterial Properties

Page 34: Cables Industria Petrolera LS Cable