Cables for alarm- and safety systems
Flexible and
safe solutions,
for decades.
We offer the widest
range of cables on
the market for every
kind of installation.
2
It´s all about reliability.It is always important to choose high quality cables,
especially when it comes to alarms and safety systems.
Even small and seemingly insignificant details can make
a big difference in terms of ease of handling, functiona-
lity and service life.
We have the cables you are looking for
We offer the widest range of cables on the market for
every kind of installation. The cables we supply carry
signals and power supplies. For extra peace of mind
concerning fire protection, our cables are available in
versions meeting specified fire safety requirements in
installations.
Halogen free for greater safety
We have decided only to include halogen free cables
in this brochure. There is a clear trend in that direc-
tion, and there is no longer any reason for not choosing
halogen free cables. Halogen free cables offer many
advantages – in particular, they make it easier to escape
the building in the event of fire, generating substantial
savings in the long run.
100 years of experience thrown in
At Nexans we research, develop and manufacture cables
for the whole world. For different environments and cli-
mates. And we’ve been doing it for more than a hundred
years. So when you choose our cables, they come with a
whole lot more – our dedication and all the experience
and expertise we’ve built up over the decades.
3
Product segments
Fire alarms Detector networks often occupy
large volumes so cables must be
easy to install. Nexans cables are
easy to strip and are optimised
to simplify installation in pipes.
Choose from simple, non twisted
pair cables for small conventional
systems and twisted pair cables for
larger addressable systems. The
cables used in fire alarm detector
networks should normally have a
red sheath. If the cables are requi-
red to keep working during a fire,
you should use Nexans Alsecure®
(see page 12 ”Performance during
a fire”).
Video surveillance (CCTV) Locally installed CCTV (closed circuit
TV) systems are increasingly being
used as a crime prevention tool.
4
Access protection Burglar alarms usually have a
system of control units and sensors.
Indoor and outdoor entry systems
contain card readers, central units
and computers. The cables used
for intruder protection and entry
control are signal cables with vary-
ing flexibility, shielding and cores.
Alternatively, combination cables
can be used with separate cores
carrying the power supply.
Nexans’ wide range makes it easy
to choose the right cables for the
various components.
Performance during a fireThere is a separate fire class for
cables that are required to maintain
sircuit integrity during a fire. These
cables all have unique insulation
material that is not damaged like
normal cables. This category can
include power supply cables as well
as signal cables. They should also
be flame retardant low fire hazard
cables – in other words they must
not give off any toxic or corrosive
gases, and only small amounts of
smoke, if there is a fire.
The Nexans cables for these appli-
cations are called Alsecure®. The
unique insulation (INFIT™) makes the
cables easy to install while ensuring
they still work during a fire.
5
CCTV (Closed Circuit TeleVision) is a locally installed
video surveillance system. A CCTV system consists of
cameras, monitors, transmission elements (cables),
control systems and storage systems. Our range of
halogen free cables for CCTV includes 75 ohm coaxial
cable.
The S/FTP Category 6A cable together with the
IP67 outlet box offers a safe and robust solution for
solutions for IP network cameras outdoor and in harsh
environments.
For added safety, vi-deo surveillance cables are also flame retar-dant and halogen free.
RG 59 LSZHCoaxial cable for video surveillance. The impedance of the
cable: 75 ohm.
Cable Nexans no. Outer diam. Length
RG 59 LSZH 19502641 6,1 mm Bobbin/100
RG 59 LSZH 19502671 6,1 mm Bobbin/500
Video surveillance (CCTV)
6
LANmark Industry outlet IP67The LANmark Industry outlet enables the installation of data
outlets in exposed areas as well as outdoor solutions. The IP67
level of protection is maintained both when the outlet is unused
and when the appropriate IP67 patchcords are connected.
Includes 2 screened category 6 or category 6A connectors.Cable Nexans no.
IP67 outer with RJ45 cat.6 shielded Snap-in connector, black. 40060109
IP67 outer with RJ45 cat.6A shielded Snap-in connector, black. 40061009
S/FTP Category 6A LSZH + PECategory 6A, 500 MHz Screened data cable. The 4 pairs are
individually foiled and covered with a common braid. Due to
the outer sheath of PE the cable is appropriate for outdoor
installation as well as in exposed areas. It can be installed indo-
ors when the PE sheet is removed. The cable fulfills cat 6A per-
formance according to EN 50288, IEC 61156 and TIA 568-B
Cable Nexans no. Outer diam. Length
Category 6A 4x2x0,5 39020771 8,6 mm B/500
7
Find out more about fire safety and fire classes.
8
You often won’t know whether you chose the right cable until after a fire.People always talk about fire protection but it is important to know what this actually
means in practical terms, and to be certain which flame spread rating you need to use.
For cables, you also need to distinguish between flame spread, fire hazard properties and
fire resistance.
Cables that prevent flame spread
Cables running through building levels and walls are a great way for fires to spread. So
the most important requirement when establishing fire protection is to use cables with
properties that prevent the spread of fire. This is why there are general flame spread
classes, and these must always be defined. Our cables have clearly marked flame spread
classes that are informative and easy to understand.
Halogen free – saving lives and money
Smoke and gases from burning cables often cause the biggest problems for people and
equipment. These problems can be reduced if halogen free cables are used. The smoke
from halogen free cables during a fire is much thinner and does not corrode metals.
This makes it easier to clear smoke from rooms, potentially saving lives. That is why our
cables for alarms and safety systems are halogen free.
Still working during a fire
The most critical cables must also be fire resistant. This means they must be guaranteed
to work even during a fire. This is made possible by special insulation material, which is
merely altered rather than destroyed by fire. The cable keeps its shape, the conductors
are kept separate and the cable continues to work. These cables are needed for the fire
alarm system itself, but also for the safety lighting guiding people out of the building, for
the smoke extraction fans and for the lifts. Our range includes fire resistant cables for
power supply and for communication.
9
Nexans has a full range of cables for fire alarm systems
The right cable for the right use
Cables for fire alarms are available with either red or grey
sheaths depending on the regulations, aesthetic requi-
rements, etc. In larger addressable systems, twisted pair
cable should be used, KLM-LSZH 2x1.0 mm. If shielded
cable is required, Nexans supplies the KLMA LSZH. If the
cables are required to keep working during a fire, fire
resistant Alsecure cables are used.
Installation
The cables for fire alarms are intended for permanent
indoor installation.
ELQRBSignal cable for fire alarms. ELQRB construction is as specified
in SS 424 16 09.
Cable Nexans no. Outer diam. Length
ELQRB 2 x 0,6 mm 18641541 2,9 x 4,2 mm Bobbin/100
ELQRB 2 x 0,6 mm 18641571 2,9 x 4,2 mm Bobbin/500
ELQRB 2 x 1,0 mm 18641641 3,3 x 4,9 mm Bobbin/100
ELQRB 2 x 1,0 mm 18641671 3,3 x 4,9 mm Bobbin/500
ELQRB 4 x 1,0 mm 18641971 5,7 mm Bobbin/500
KLM LSZH 2x1,0Halogen free, pair-twisted signal cable. The cable construction
is as specified in SS 424 16 54 (ELQYB).Cable Nexans no. Outer diam. Length
KLM LSZH 2x1,0 37159271 5,7 mm Bobbin/500
Fire alarms
KLMA LSZH Halogen free, pair-twisted signal cable. The cable construction
is as specified in SS 424 16 54 (ELQYB).Cable Nexans no. Outer diam. Length
KLMA LSZH 2x0,8 37158243 5,0 mm Coil/150
KLMA LSZH 2x0,8 37158258 5,0 mm Bobbin/600
KLMA LSZH 4x0,8 37158443 5,5 mm Coil/150
KLMA LSZH 4x0,8 37158458 5,5 mm Bobbin/600
KLM LSZH Halogen free signal cable. The cable construction is, where
applicable, as specified in SFS 2751.Cable Nexans no. Outer diam. Length
KLM LSZH 2x0,8 37156243 4,0 mm Coil/150
KLM LSZH 2x0,8 37156258 4,0 mm Bobbin/600
KLM LSZH 4x0,8 37156443 5,0 mm Coil/150
KLM LSZH 4x0,8 37156458 5,0 mm Bobbin/600
10
Fire resistant cables maintain circuit integrity even when affected by heat or flames.
11
Fire resistant cables are recommended for use in instal-
lations that must maintain circuit integrity during a fire.
Using these cables in important alarm, control, signal and
power supply systems means you can guarantee they will
not be taken down, even if the fire reaches the cables
themselves.
No gases, little smoke
As well as continuing to work during and after a fire,
Nexans fire resistant cables are halogen free so they do
not release any toxic or corrosive gases, and only small
amounts of smoke, if there is a fire. Studies show that this
can save lives and money.
Installation
Examples of systems that must maintain circuit integrity
during a fire include signal and safety systems guiding
people out of the building. Other examples are smoke
extraction fans and lifts. Fire alarm cables, too, if they
pass through areas that are not monitored by detectors,
are required to maintain circuit integrity during a fire.
ALSECURE® PLUS TEL, screenedFire resistant, twisted pair, shielded telecom and signal cables
for permanent installation indoors or in pipes. Fire performance
according to IEC60331, IEC 60332-3.Cable Nexans
no.Outer diam.
Length
Alsecure Plus Tel 1 x 2 x 0,9 mm 17541198 6,7 mm Drum/500
Alsecure Plus Tel 2 x 2 x 0,9 mm 17541298 7,4 mm Drum/500
Alsecure Plus Tel 10 x 2 x 0,9 mm 17541698 16,0 mm Drum/500
ALSECURE® PREMIUMFire resistant, twisted pair, fire alarm cables for permanent
installation indoors or in pipes. Fire performance according to
IEC60331, IEC 60332-3. Cable Nexans
no.Outer diam.
Length
Alsecure Premium 2 x 1,0 mm 17542171 6,2 mm Bobbin/500
Alsecure Premium 10 x 2 x 1,0 mm 17542698 17,0 mm Drum/500
ALSECURE® PLUS 0,6/1kV, FRHFFire resistant power cable with round or sector shaped, stranded,
soldered copper conductor and concentric shielding. For perma-
nent installation in all areas. Fire performance according to IEC
60331, IEC 60332-3.Cable Nexans no. Outer diam. Length
Alsecure Plus 1kV 2 x 1,5/1,5 27005698 11,9 mm Drum/500
Alsecure Plus 1kV 3 x 1,5/1,5 27004498 12,5 mm Drum/500
Alsecure Plus 1kV 4 x 1,5/1,5 27005798 15,2 mm Drum/500
Alsecure Plus 1kV 2 x 2,5/2,5 27005898 14,7 mm Drum/500
Alsecure Plus 1kV 3 x 2,5/2,5 27005998 15,2 mm Drum/500
Alsecure Plus 1kV 4 x 2,5/2,5 27030198 16,4 mm Drum/500
Alsecure Plus 1kV 4 x 6/6 35123998 18,1 mm Drum/500
Alsecure Plus 1kV 4 x 10/10 35124198 22,0 mm Drum/500
Alsecure Plus 1kV 4 x 16/16 35124398 24,2 mm Drum/500
Alsecure Plus 1kV 4 x 25/16 35124598 26,0 mm Drum/500
Alsecure Plus 1kV 4 x 35/16 35124798 30,0 mm Drum/500
Alsecure Plus 1kV 4 x 50/25 35126598 35,0 mm Drum/500
Alsecure Plus 1kV 4 x 70/35 35125198 36,0 mm Drum/500
Alsecure Plus 1kV 4 x 95/50 35125398 41,0 mm Drum/500
Alsecure Plus 1kV 4 x 120/70 35125598 42,2 mm Drum/500
Alsecure Plus 1kV 4 x 150/70 35125798 49,0 mm Drum/500
Alsecure Plus 1kV 4 x 185/95 35125898 52,0 mm Drum/500
Alsecure Plus 1kV 4 x 240/120 35126198 60,0 mm Drum/500
Performance during a fire
12
Another important fire safety property is low smoke development.
ALSECURE® PREMIUM 300/500VFire resistant, halogen free control cables with round, solid
copper conductors. This cable is designed for permanent instal-
lation on cable ladders, directly on walls or in pipes or ducting.
Applications include emergency lighting, fire alarm systems and
control systems. Fire performance according to IEC60331, IEC
60332-3.Cable Nexans no. Outer diam. Length
Alsecure Premium 3G1,5 27010098 8,0 mm Drum/500
Alsecure Premium 3G2,5 27010198 10,0 mm Drum/500
Alsecure Premium 4G1,5 27010298 9,5 mm Drum/500
Alsecure Premium 5G1,5 27010398 10,0 mm Drum/500
Alsecure Premium 5G2,5 27010598 12,0 mm Drum/500
ALSECURE® PLUS STYR 300/500VFire resistant, halogen free, unshielded installation cables with
round, solid copper conductors. For permanent installation
on cable ladders, directly on walls or in pipes or ducting. Fire
performance according to IEC60331, IEC 60332-3.
Cable Nesans no. Outer diam. Length
Alsecure Plus Styr 7G1,5 27001498 14,0 mm Drum/500
Alsecure Plus Styr 12G1,5 27001198 19,5 mm Drum/500
Alsecure Plus Styr 19G1,5 27004198 22,5 mm Drum/500
Alsecure Plus Styr 7G2,5 27008298 16,0 mm Drum/500
13
Access protectionOur cables for intruder alarms and entry systems come in
a range of types. We have shielded as well as unshielded
twisted pair cables – up to ten pairs. We also offer flexible
single wire cables with 4 to 12 cores. Combination cables
are also available for entry systems – cables with twisted
pair signal elements and power supply elements (max 100
V).
MHS LSZHPair-twisted, shielded communication cable with halogen free,
flame retardant sheath. The cable construction is, where appli-
cable, as specified in SFS 5739.
Cable Nexans no. Outer diam. Length
MHS LSZH 1x4x0,5 38565040 5,0 Coil/100
MHS LSZH 1x4x0,5 38565098 5,0 Drum/1000
MHS LSZH 3x2x0,5 38565145 6,0 Coil/200
MHS LSZH 3x2x0,5 38565198 6,0 Drum/1000
MHS LSZH 5x2x0,5 38565243 6,5 Coil/150
MHS LSZH 5x2x0,5 38565298 6,5 Drum/1000
MHS LSZH 10x2x0,5 38565340 8,5 Coil/100
MHS LSZH 10x2x0,5 38565398 8,5 Drum/1000
EQQXB Easy TM (halogen free EKKX)Pair-twisted communication cable with halogen free, flame retar-
dant insulation and sheath. An important feature of the cable is
that both insulation and sheath are easy to peel. You can even
peel the insulation with your nail. Fire performance according to
IEC 60332-1.
Cable Nexans no.
Outer diam.
Length
EQQXB Easy TM 1 x 4 x 0,5 mm 17116041 3,5 mm Bobbin/100
EQQXB Easy TM 1 x 4 x 0,5 mm 17116071 3,5 mm Bobbin/500
EQQXB Easy TM 2 x 2 x 0,5 mm 17116141 4,3 mm Bobbin/100
EQQXB Easy TM 2 x 2 x 0,5 mm 17116171 4,3 mm Bobbin/500
EQQXB Easy TM 4 x 2 x 0,5 mm 17116341 5,5 mm Bobbin/100
EQQXB Easy TM 4 x 2 x 0,5 mm 17116371 5,5 mm Bobbin/500
EQQXB Easy TM 6 x 2 x 0,5 mm 17116441 6,0 mm Bobbin/100
EQQXB Easy TM 6 x 2 x 0,5 mm 17116471 6,0 mm Bobbin/500
EQQXB Easy TM 10 x 2 x 0,5 mm 17116641 7,3 mm Bobbin/100
EQQXB Easy TM 10 x 2 x 0,5 mm 17116671 7,3 mm Bobbin/500
FQQXBFlexible signal and alarm cables for intruder alarms and access
control systems. Cable Nexans no. Outer diam. Length
FQQXB 4 x 0,22 mm2 17523141 3,7 mm Bobbin/100
FQQXB 4 x 0,22 mm2 17523171 3,7 mm Bobbin/500
FQQXB 6 x 0,22 mm2 17523241 4,2 mm Bobbin/100
FQQXB 6 x 0,22 mm2 17523271 4,2 mm Bobbin/500
FQQXB 8 x 0,22 mm2 17523341 4,7 mm Bobbin/100
FQQXB 8 x 0,22 mm2 17523371 4,7 mm Bobbin/500
FQQXB 12 x 0,22 mm2 17523441 5,4 mm Bobbin/100
FQQXB 12 x 0,22 mm2 17523471 5,4 mm Bobbin/500
FQQXB 4 x 2 x 0,22 mm2 17524271 5,3 mm Bobbin/500
FQQXB 10 x 2 x 0,22 mm2 17524898 8,0 mm Drum/500
14
FLAQQBRCombined power supply and signal cables for intruder alarms
and entry systems. The twisted pair signal element is unshielded.Cable Nexans
no.Outer diam.
Length
FLAQQBR 2 x 1,0 + 1 x 2 x 0,22 mm2 17033341 6,5 mm Bobbin/100
FLAQQBR 2 x 1,0 + 1 x 2 x 0,22 mm2 17033371 6,5 mm Bobbin/500
FLAQQBR 2 x 1,0 + 2 x 2 x 0,22 mm2 17515198 8,0 mm Drum/500
FLAQQBR 3 x 1,0 + 2 x 2 x 0,6 mm 17034298 8,5 mm Drum/500
FLQQBRCombined power supply and signal cables for intruder alarms
and entry systems. The twisted pair signal element is unshielded.Cable Nexans
no.Outer diam.
Length
FLQQBR 2 x 1,5 + 2 x 2 x 0,5 mm2 17513198 8,5 mm Drum/500
FLQQBR 2 x 1,0 + 1 x 2 x 0,22 mm2 17513041 6,5 mm Bobbin/100
FLQQBR 2 x 1,0 + 1 x 2 x 0,22 mm2 17513071 6,5 mm Bobbin/500
FLQQBR 2 x 1,0 + 2 x 2 x 0,22 mm2 17513271 7,5 mm Bobbin/500
We have the exact
cable that complies
to all your needs.
FLAQQLYCombined power supply and signal cable for intruder alarms
and entry systems. The pairs for signalling have a common
screen of aluminium/polyesterfoil.
The cable has a protective PE sheath covering the inner sheat of
halogen free flame retardant plastic compound and is intended
for fixed installations both indoor and outdoor.
Cabel Nexans no.
Outer diam.
Length
FLAQQLY 2 x 1,0 + 2 x 2 x 0,22 mm2 17039298 9,0 mm Drum/500
15
Nexans Sweden AB, 514 81 Grimsås, www.nexans.se
Learn more about what significates our cables for