Cable measuring example

6
1 Integrus Tech Cable Measur ing ST/SEU-CO | | 16.Feb.0 6 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. Security Systems INTEGRUS INTEGRUS Cable measuring example Transmitter R3 R4 20m 40m

description

Transmitter. 20m. R3. R4. 40m. Cable measuring example. Step 1 Signal Delay Factor of Used Cable. Use the Signal Delay Factor that is specified by the manufacturer of the cable. 20m. 30m. 30m. 20m. 40m. 20m. Step 2 Measure the Cable Lengths. R3=20m. R1=30m. R2=30+20=50m. - PowerPoint PPT Presentation

Transcript of Cable measuring example

1 Integrus Tech Cable MeasuringST/SEU-CO | |16.Feb.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of

disposal such as copying and passing on to third parties.

Security Systems INTEGRUSINTEGRUS

Cable measuring example

TransmitterTransmitter

R3R4

20m

40m

2 Integrus Tech Cable MeasuringST/SEU-CO | |16.Feb.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of

disposal such as copying and passing on to third parties.

Security Systems INTEGRUSINTEGRUS

Step 1 Signal Delay Factor of Used Cable

Use the Signal Delay Factor that is specified by the

manufacturer of the cable.

3 Integrus Tech Cable MeasuringST/SEU-CO | |16.Feb.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of

disposal such as copying and passing on to third parties.

Security Systems INTEGRUSINTEGRUS

30m 20m

R1=30m

R2=30+20=50m

R3=20m

R4=20+40=60m

40m

20m

20m

30m

Step 2 Measure the Cable Lengths

4 Integrus Tech Cable MeasuringST/SEU-CO | |16.Feb.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of

disposal such as copying and passing on to third parties.

Security Systems INTEGRUSINTEGRUS

R1=30 * 5.6 = 168ns

R2= 50 * 5.6 = 280ns

R3=20 * 5.6 = 112ns

R4=60 * 5.6 = 336ns

Step 3 Cable lengths * Cable Delay Factor

(Example)Cable Signal Delay

=5.6 ns/m

R4=60 * 5.6 = 336ns

5 Integrus Tech Cable MeasuringST/SEU-CO | |16.Feb.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of

disposal such as copying and passing on to third parties.

Security Systems INTEGRUSINTEGRUS

Step 4 Calculate Delay Switch Positions

(336 – 168) / 33 = 5.39

Switch Position =

(Max. Signal Delay – Delay Rx) / 33

(336 – 280) / 33 = 1.69

(336 – 336) / 33 = 0

(336 – 112) / 33 = 6.78

5

2 0

7

6 Integrus Tech Cable MeasuringST/SEU-CO | |16.Feb.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of

disposal such as copying and passing on to third parties.

Security Systems INTEGRUSINTEGRUS

Cable measuring example