Cable Management
![Page 2: Cable Management. DATA CABLE IS SUSCEPTIBLE TO DAMAGE INSTALLING CAT5 CABLE DOES NOT GUARANTEE CAT5 PERFORMANCE HOW CABLE IS INSTALLED, NOT ONLY WHAT.](https://reader035.fdocuments.net/reader035/viewer/2022070306/551953e2550346b5698b4598/html5/thumbnails/2.jpg)
• DATA CABLE IS SUSCEPTIBLE TO DAMAGE
• INSTALLING CAT5 CABLE DOES NOT GUARANTEE CAT5
PERFORMANCE
• HOW CABLE IS INSTALLED, NOT ONLY WHAT TYPE OF
CABLE IS INSTALLED
![Page 3: Cable Management. DATA CABLE IS SUSCEPTIBLE TO DAMAGE INSTALLING CAT5 CABLE DOES NOT GUARANTEE CAT5 PERFORMANCE HOW CABLE IS INSTALLED, NOT ONLY WHAT.](https://reader035.fdocuments.net/reader035/viewer/2022070306/551953e2550346b5698b4598/html5/thumbnails/3.jpg)
• IF CABLE NOT INSTALLED PROPERLY
PROBLEMS WITH
– ATTENUATION
– NEXT
– PS NEXT
– FEXT
– PS FEXT
![Page 4: Cable Management. DATA CABLE IS SUSCEPTIBLE TO DAMAGE INSTALLING CAT5 CABLE DOES NOT GUARANTEE CAT5 PERFORMANCE HOW CABLE IS INSTALLED, NOT ONLY WHAT.](https://reader035.fdocuments.net/reader035/viewer/2022070306/551953e2550346b5698b4598/html5/thumbnails/4.jpg)
• ANSI/TIA/EIA-568-A 10.6.3.2 SPECIFIES
– APPROPRIATE CABLE MANAGEMENT MUST BE USED TO
ELIMINATE
• CABLE STRESS • UNTWISTING OF PAIRS
• CABLE CINCHING • TWISTING OF CABLE
– CABLE MUST ALSO BE INSTALLED TO MANUFACTURES
SPECIFICATIONS
![Page 5: Cable Management. DATA CABLE IS SUSCEPTIBLE TO DAMAGE INSTALLING CAT5 CABLE DOES NOT GUARANTEE CAT5 PERFORMANCE HOW CABLE IS INSTALLED, NOT ONLY WHAT.](https://reader035.fdocuments.net/reader035/viewer/2022070306/551953e2550346b5698b4598/html5/thumbnails/5.jpg)
SURFACE RACEWAY
• COVERED BY EIA/TIA-569 SECT.4.7
• LISTED IN FOUR (4) SUBGROUPS :– SURFACE RACEWAY
– RECESSED RACEWAY
– MOLDING RACEWAY
– MULTICHANNEL RACEWAY
![Page 6: Cable Management. DATA CABLE IS SUSCEPTIBLE TO DAMAGE INSTALLING CAT5 CABLE DOES NOT GUARANTEE CAT5 PERFORMANCE HOW CABLE IS INSTALLED, NOT ONLY WHAT.](https://reader035.fdocuments.net/reader035/viewer/2022070306/551953e2550346b5698b4598/html5/thumbnails/6.jpg)
• AGAIN CABLE MUST
– NOT BE PUT UNDER STRAIN
– MAINTAIN A MINIMUM BEND RADIUS
– BE SUPPORTED (REGARDLESS OF TYPE)
– BE IN A SUITABLE ENVIRONMENT
– PROTECTED FROM EMI (e.g. RFI) (COPPER ONLY)
(BOTH COPPER & FIBRE)
![Page 7: Cable Management. DATA CABLE IS SUSCEPTIBLE TO DAMAGE INSTALLING CAT5 CABLE DOES NOT GUARANTEE CAT5 PERFORMANCE HOW CABLE IS INSTALLED, NOT ONLY WHAT.](https://reader035.fdocuments.net/reader035/viewer/2022070306/551953e2550346b5698b4598/html5/thumbnails/7.jpg)
DON’TS
• NEVER PULL CABLE DIRECTLY ACROSS SUSPENDED CEILING
TILE OR ACROSS FLORESCENT LIGHT BOXES (EMI)
• CABLE SHOULD NOT BE TIED TO CEILING GRIDWORK WIRES
![Page 8: Cable Management. DATA CABLE IS SUSCEPTIBLE TO DAMAGE INSTALLING CAT5 CABLE DOES NOT GUARANTEE CAT5 PERFORMANCE HOW CABLE IS INSTALLED, NOT ONLY WHAT.](https://reader035.fdocuments.net/reader035/viewer/2022070306/551953e2550346b5698b4598/html5/thumbnails/8.jpg)
WHAT NOT TO DO
![Page 9: Cable Management. DATA CABLE IS SUSCEPTIBLE TO DAMAGE INSTALLING CAT5 CABLE DOES NOT GUARANTEE CAT5 PERFORMANCE HOW CABLE IS INSTALLED, NOT ONLY WHAT.](https://reader035.fdocuments.net/reader035/viewer/2022070306/551953e2550346b5698b4598/html5/thumbnails/9.jpg)
MANAGEMENT TYPES
• THERE ARE VARIOUS DIFFERENT TYPES OF CABLE MANAGEMENT EACH GIVING DIFFERENT DEGREES AND TYPES OF PROTECTION
![Page 10: Cable Management. DATA CABLE IS SUSCEPTIBLE TO DAMAGE INSTALLING CAT5 CABLE DOES NOT GUARANTEE CAT5 PERFORMANCE HOW CABLE IS INSTALLED, NOT ONLY WHAT.](https://reader035.fdocuments.net/reader035/viewer/2022070306/551953e2550346b5698b4598/html5/thumbnails/10.jpg)
CABLE TIES
• USED TO SECURE CABLE TO TRAYS, TRUNKING ETC.
• NYLON, POLYPROPYLENE
• RELEASABLE, NON-RELEASABLE
• RIBBED INNER SURFACE TO SECURE CABLE
![Page 11: Cable Management. DATA CABLE IS SUSCEPTIBLE TO DAMAGE INSTALLING CAT5 CABLE DOES NOT GUARANTEE CAT5 PERFORMANCE HOW CABLE IS INSTALLED, NOT ONLY WHAT.](https://reader035.fdocuments.net/reader035/viewer/2022070306/551953e2550346b5698b4598/html5/thumbnails/11.jpg)
![Page 12: Cable Management. DATA CABLE IS SUSCEPTIBLE TO DAMAGE INSTALLING CAT5 CABLE DOES NOT GUARANTEE CAT5 PERFORMANCE HOW CABLE IS INSTALLED, NOT ONLY WHAT.](https://reader035.fdocuments.net/reader035/viewer/2022070306/551953e2550346b5698b4598/html5/thumbnails/12.jpg)
“J” HOOK BENEFITS
• DESIGNED FOR “HIGH PERFORMANCE” CABLE
• USED SPARINGLY OVER SHORT RUNS
• LIMITS THE NEED FOR CABLE TIES
![Page 13: Cable Management. DATA CABLE IS SUSCEPTIBLE TO DAMAGE INSTALLING CAT5 CABLE DOES NOT GUARANTEE CAT5 PERFORMANCE HOW CABLE IS INSTALLED, NOT ONLY WHAT.](https://reader035.fdocuments.net/reader035/viewer/2022070306/551953e2550346b5698b4598/html5/thumbnails/13.jpg)
“J” HOOKS SHOULD NOT BE USED AS A REPLACEMENT FOR CABLE TRAY
![Page 14: Cable Management. DATA CABLE IS SUSCEPTIBLE TO DAMAGE INSTALLING CAT5 CABLE DOES NOT GUARANTEE CAT5 PERFORMANCE HOW CABLE IS INSTALLED, NOT ONLY WHAT.](https://reader035.fdocuments.net/reader035/viewer/2022070306/551953e2550346b5698b4598/html5/thumbnails/14.jpg)
D-RINGS
• AS WITH J-HOOKS
• FOR SMALL BUNDLES OF
CABLE
• USED SPARINGLY OVER
SHORT RUNS
![Page 15: Cable Management. DATA CABLE IS SUSCEPTIBLE TO DAMAGE INSTALLING CAT5 CABLE DOES NOT GUARANTEE CAT5 PERFORMANCE HOW CABLE IS INSTALLED, NOT ONLY WHAT.](https://reader035.fdocuments.net/reader035/viewer/2022070306/551953e2550346b5698b4598/html5/thumbnails/15.jpg)
A
B
• THE J-HOOKS ARE NOT ADEQUATE SUPPORT HERE
• THE CABLE IS UNDER STRESS AT POINTS A & B
![Page 16: Cable Management. DATA CABLE IS SUSCEPTIBLE TO DAMAGE INSTALLING CAT5 CABLE DOES NOT GUARANTEE CAT5 PERFORMANCE HOW CABLE IS INSTALLED, NOT ONLY WHAT.](https://reader035.fdocuments.net/reader035/viewer/2022070306/551953e2550346b5698b4598/html5/thumbnails/16.jpg)
CABLE LADDER
• GALVANISED STEEL OR PVC
• CABLE SECURED AT RUNGS
![Page 17: Cable Management. DATA CABLE IS SUSCEPTIBLE TO DAMAGE INSTALLING CAT5 CABLE DOES NOT GUARANTEE CAT5 PERFORMANCE HOW CABLE IS INSTALLED, NOT ONLY WHAT.](https://reader035.fdocuments.net/reader035/viewer/2022070306/551953e2550346b5698b4598/html5/thumbnails/17.jpg)
CABLE LADDER
• WITH LARGE BUNDLES CABLE UNDER PRESSURE AT RUNGS BECAUSE ITS WEIGHT IS NOT DISTRIBUTED ALONG A RUN
![Page 18: Cable Management. DATA CABLE IS SUSCEPTIBLE TO DAMAGE INSTALLING CAT5 CABLE DOES NOT GUARANTEE CAT5 PERFORMANCE HOW CABLE IS INSTALLED, NOT ONLY WHAT.](https://reader035.fdocuments.net/reader035/viewer/2022070306/551953e2550346b5698b4598/html5/thumbnails/18.jpg)
AS WITH CABLE LADDERS CABLE WEIGHT NOT EVENLY DISTRIBUTED. BASKET IS CHEAPER AND EASIER TO INSTALL THAN LADDER
CABLE BASKETS
![Page 19: Cable Management. DATA CABLE IS SUSCEPTIBLE TO DAMAGE INSTALLING CAT5 CABLE DOES NOT GUARANTEE CAT5 PERFORMANCE HOW CABLE IS INSTALLED, NOT ONLY WHAT.](https://reader035.fdocuments.net/reader035/viewer/2022070306/551953e2550346b5698b4598/html5/thumbnails/19.jpg)
SNAKE TRAY
• SIMILAR TO CABLE BASKET
• FLEXIBLE
• EASIER TO INSTALL?
![Page 20: Cable Management. DATA CABLE IS SUSCEPTIBLE TO DAMAGE INSTALLING CAT5 CABLE DOES NOT GUARANTEE CAT5 PERFORMANCE HOW CABLE IS INSTALLED, NOT ONLY WHAT.](https://reader035.fdocuments.net/reader035/viewer/2022070306/551953e2550346b5698b4598/html5/thumbnails/20.jpg)
• FLEXIBLE
![Page 21: Cable Management. DATA CABLE IS SUSCEPTIBLE TO DAMAGE INSTALLING CAT5 CABLE DOES NOT GUARANTEE CAT5 PERFORMANCE HOW CABLE IS INSTALLED, NOT ONLY WHAT.](https://reader035.fdocuments.net/reader035/viewer/2022070306/551953e2550346b5698b4598/html5/thumbnails/21.jpg)
CABLE TRAYS
• GALVANISED STEEL OR PVC
• VARIOUS DIMENSIONS
• MAY BE RESIZED WITH
HACKSAW
• ANGULAR INSERTS AVAILABLE
![Page 22: Cable Management. DATA CABLE IS SUSCEPTIBLE TO DAMAGE INSTALLING CAT5 CABLE DOES NOT GUARANTEE CAT5 PERFORMANCE HOW CABLE IS INSTALLED, NOT ONLY WHAT.](https://reader035.fdocuments.net/reader035/viewer/2022070306/551953e2550346b5698b4598/html5/thumbnails/22.jpg)
CABLE TRAYS
• PERFORATED BOTTOM
• HORIZONTAL & BACKBONE
• FLEXIBLE
• EASY ACCESS TO CABLE
• CURVED TRAYS
• SUPPORTS WEIGHT OF CABLE
ALONG WHOLE RUN
![Page 23: Cable Management. DATA CABLE IS SUSCEPTIBLE TO DAMAGE INSTALLING CAT5 CABLE DOES NOT GUARANTEE CAT5 PERFORMANCE HOW CABLE IS INSTALLED, NOT ONLY WHAT.](https://reader035.fdocuments.net/reader035/viewer/2022070306/551953e2550346b5698b4598/html5/thumbnails/23.jpg)
CONDUIT
• COMPLETELY ENCLOSED
• NO REMOVABLE LID
• GALVANISED STEEL PVC
• ACCESS TO CABLE LIMITED
![Page 24: Cable Management. DATA CABLE IS SUSCEPTIBLE TO DAMAGE INSTALLING CAT5 CABLE DOES NOT GUARANTEE CAT5 PERFORMANCE HOW CABLE IS INSTALLED, NOT ONLY WHAT.](https://reader035.fdocuments.net/reader035/viewer/2022070306/551953e2550346b5698b4598/html5/thumbnails/24.jpg)
CONDUIT
• EMI PROTECTION
• OUTLET DENSITIES LOW
• MEDIUM TO LONG TERM
• NEAT & AESTHETIC
![Page 25: Cable Management. DATA CABLE IS SUSCEPTIBLE TO DAMAGE INSTALLING CAT5 CABLE DOES NOT GUARANTEE CAT5 PERFORMANCE HOW CABLE IS INSTALLED, NOT ONLY WHAT.](https://reader035.fdocuments.net/reader035/viewer/2022070306/551953e2550346b5698b4598/html5/thumbnails/25.jpg)
TRUNKING
• SIMILAR TO CABLE TRAY BUT
• REMOVABLE LID (BETTER PROTECTION) (EMI & RODENT)
![Page 26: Cable Management. DATA CABLE IS SUSCEPTIBLE TO DAMAGE INSTALLING CAT5 CABLE DOES NOT GUARANTEE CAT5 PERFORMANCE HOW CABLE IS INSTALLED, NOT ONLY WHAT.](https://reader035.fdocuments.net/reader035/viewer/2022070306/551953e2550346b5698b4598/html5/thumbnails/26.jpg)
TRUNKING
• MORE DIFFICULT TO CUT (LID)
• NEATER
![Page 27: Cable Management. DATA CABLE IS SUSCEPTIBLE TO DAMAGE INSTALLING CAT5 CABLE DOES NOT GUARANTEE CAT5 PERFORMANCE HOW CABLE IS INSTALLED, NOT ONLY WHAT.](https://reader035.fdocuments.net/reader035/viewer/2022070306/551953e2550346b5698b4598/html5/thumbnails/27.jpg)
RACEWAYS
• SIMILAR TO TRUNKING
• VISUALLY PLEASING
• EASILY MODIFIED
![Page 28: Cable Management. DATA CABLE IS SUSCEPTIBLE TO DAMAGE INSTALLING CAT5 CABLE DOES NOT GUARANTEE CAT5 PERFORMANCE HOW CABLE IS INSTALLED, NOT ONLY WHAT.](https://reader035.fdocuments.net/reader035/viewer/2022070306/551953e2550346b5698b4598/html5/thumbnails/28.jpg)
• POWER AND DATA CABLING
![Page 29: Cable Management. DATA CABLE IS SUSCEPTIBLE TO DAMAGE INSTALLING CAT5 CABLE DOES NOT GUARANTEE CAT5 PERFORMANCE HOW CABLE IS INSTALLED, NOT ONLY WHAT.](https://reader035.fdocuments.net/reader035/viewer/2022070306/551953e2550346b5698b4598/html5/thumbnails/29.jpg)
POWER AND DATA SEPARATION
![Page 30: Cable Management. DATA CABLE IS SUSCEPTIBLE TO DAMAGE INSTALLING CAT5 CABLE DOES NOT GUARANTEE CAT5 PERFORMANCE HOW CABLE IS INSTALLED, NOT ONLY WHAT.](https://reader035.fdocuments.net/reader035/viewer/2022070306/551953e2550346b5698b4598/html5/thumbnails/30.jpg)
![Page 31: Cable Management. DATA CABLE IS SUSCEPTIBLE TO DAMAGE INSTALLING CAT5 CABLE DOES NOT GUARANTEE CAT5 PERFORMANCE HOW CABLE IS INSTALLED, NOT ONLY WHAT.](https://reader035.fdocuments.net/reader035/viewer/2022070306/551953e2550346b5698b4598/html5/thumbnails/31.jpg)
MIN BEND RADIUS
![Page 32: Cable Management. DATA CABLE IS SUSCEPTIBLE TO DAMAGE INSTALLING CAT5 CABLE DOES NOT GUARANTEE CAT5 PERFORMANCE HOW CABLE IS INSTALLED, NOT ONLY WHAT.](https://reader035.fdocuments.net/reader035/viewer/2022070306/551953e2550346b5698b4598/html5/thumbnails/32.jpg)
A
• DROPOUT PIECE ENSURES MIN BEND RADIUS IS MAINTAINED
• PRESSURE AT RUNG A IS ALLEVIATED
![Page 33: Cable Management. DATA CABLE IS SUSCEPTIBLE TO DAMAGE INSTALLING CAT5 CABLE DOES NOT GUARANTEE CAT5 PERFORMANCE HOW CABLE IS INSTALLED, NOT ONLY WHAT.](https://reader035.fdocuments.net/reader035/viewer/2022070306/551953e2550346b5698b4598/html5/thumbnails/33.jpg)
CABLE TRAY ASSEMBLIES
![Page 34: Cable Management. DATA CABLE IS SUSCEPTIBLE TO DAMAGE INSTALLING CAT5 CABLE DOES NOT GUARANTEE CAT5 PERFORMANCE HOW CABLE IS INSTALLED, NOT ONLY WHAT.](https://reader035.fdocuments.net/reader035/viewer/2022070306/551953e2550346b5698b4598/html5/thumbnails/34.jpg)
What is EMI?
• ELECTRO MAGNETIC INTERFERENCE– DESCRIBES ALL KINDS OF ELECTRICAL AND MAGNETIC
INTERFERENCE
• EMI IS A FIELD THAT EMANATES FROM ‘LIVE’ CONDUCTORS
– CAN TRAVEL LARGE DISTANCES AND INTERFERE WITH OTHER CONDUCTORS
• RFI (RADIO FREQUENCY INTERFERENCE)– 98FM CAN INTERFERE WITH CONDUCTORS
![Page 35: Cable Management. DATA CABLE IS SUSCEPTIBLE TO DAMAGE INSTALLING CAT5 CABLE DOES NOT GUARANTEE CAT5 PERFORMANCE HOW CABLE IS INSTALLED, NOT ONLY WHAT.](https://reader035.fdocuments.net/reader035/viewer/2022070306/551953e2550346b5698b4598/html5/thumbnails/35.jpg)
Sources of EMI
• SOME ‘LIVE’ CONDUCTORS CAN CAUSE MORE
INTERFERENCE THAN OTHERS
– DEPENDS ON SEVERAL FACTORS, SUCH AS THE AMOUNT OF
CURRENT THEY ARE CARRYING AND THE AMOUNT OF SCREENING
AROUND THE CONDUCTOR
• FLUORESCENT LIGHTING, SUBSTATIONS, MOTORS, SWITCH
MODE POWER SUPPLIES
![Page 36: Cable Management. DATA CABLE IS SUSCEPTIBLE TO DAMAGE INSTALLING CAT5 CABLE DOES NOT GUARANTEE CAT5 PERFORMANCE HOW CABLE IS INSTALLED, NOT ONLY WHAT.](https://reader035.fdocuments.net/reader035/viewer/2022070306/551953e2550346b5698b4598/html5/thumbnails/36.jpg)
Vulnerability
• SOME CONDUCTORS CAN PICK UP INTERFERENCE MORE EASILY THAN OTHERS
– UTP IS PARTICULARLY VULNERABLE TO PICKING UP EMI
– SCREENED CONDUCTORS OR CONDUCTORS IN EARTHED ENCLOSURES ARE LESS VULNERABLE BUT HAVE TO BE CAREFUL
– FIBRE IS IMMUNE TO EMI
![Page 37: Cable Management. DATA CABLE IS SUSCEPTIBLE TO DAMAGE INSTALLING CAT5 CABLE DOES NOT GUARANTEE CAT5 PERFORMANCE HOW CABLE IS INSTALLED, NOT ONLY WHAT.](https://reader035.fdocuments.net/reader035/viewer/2022070306/551953e2550346b5698b4598/html5/thumbnails/37.jpg)
EN 50174
• MAKES THE FOLLOWING RECOMMENDATIONS
![Page 38: Cable Management. DATA CABLE IS SUSCEPTIBLE TO DAMAGE INSTALLING CAT5 CABLE DOES NOT GUARANTEE CAT5 PERFORMANCE HOW CABLE IS INSTALLED, NOT ONLY WHAT.](https://reader035.fdocuments.net/reader035/viewer/2022070306/551953e2550346b5698b4598/html5/thumbnails/38.jpg)
En 50174
• EUROPEAN STANDARD SUBMITTED TO CENELEC
• THREE PARTS– SPECIFICATION– IMPLEMENTATION – OPERATIONS
OF INFORMATION TECHNOLOGY CABLING,BOTH COPPER & FIBRE}
![Page 39: Cable Management. DATA CABLE IS SUSCEPTIBLE TO DAMAGE INSTALLING CAT5 CABLE DOES NOT GUARANTEE CAT5 PERFORMANCE HOW CABLE IS INSTALLED, NOT ONLY WHAT.](https://reader035.fdocuments.net/reader035/viewer/2022070306/551953e2550346b5698b4598/html5/thumbnails/39.jpg)
![Page 40: Cable Management. DATA CABLE IS SUSCEPTIBLE TO DAMAGE INSTALLING CAT5 CABLE DOES NOT GUARANTEE CAT5 PERFORMANCE HOW CABLE IS INSTALLED, NOT ONLY WHAT.](https://reader035.fdocuments.net/reader035/viewer/2022070306/551953e2550346b5698b4598/html5/thumbnails/40.jpg)
• EMI PERFORMANCE DIFFERS WITH THE DIFFERENT TRAY TYPES
![Page 41: Cable Management. DATA CABLE IS SUSCEPTIBLE TO DAMAGE INSTALLING CAT5 CABLE DOES NOT GUARANTEE CAT5 PERFORMANCE HOW CABLE IS INSTALLED, NOT ONLY WHAT.](https://reader035.fdocuments.net/reader035/viewer/2022070306/551953e2550346b5698b4598/html5/thumbnails/41.jpg)
• THE BUNDLE HEIGHT INTO THE CABLE TRAY SHALL BE LOWER THAN THE SIDE WALLS AS ILLUSTRATED ABOVE
• OVERLAPPING LIDS PROVIDE MORE PROTECTION
• DEEP CONDUITS ARE PREFERRED
![Page 42: Cable Management. DATA CABLE IS SUSCEPTIBLE TO DAMAGE INSTALLING CAT5 CABLE DOES NOT GUARANTEE CAT5 PERFORMANCE HOW CABLE IS INSTALLED, NOT ONLY WHAT.](https://reader035.fdocuments.net/reader035/viewer/2022070306/551953e2550346b5698b4598/html5/thumbnails/42.jpg)
CABLE SUPPORT
• PROPER CAT 5 PERFORMANCE WILL ONLY BE ACHIEVED WITH
CAREFUL CABLE INSTALLATION AND ADEQUATE SUPPORT
• MAKE SURE “YOUR” INSTALLATIONS ARE NOT PART OF THE 80 %
THAT WILL NOT SUPPORT TRANSMISSION IN THE FUTURE OF 100
Mbps AND BEYOND