Cable Hmwpe

2
 CABLE HMWPE IMPRESSED CURRENT CATHODIC PROTECTION DATASHEET 2.6.7 REVISION 1  Ventu re Way , Grantham, Lincs NG31 7XS UK. T el: +44 (0)1476 590666 Fax: +44 (0)1476 570605 Email: [email protected] Website: www.cathodic.co.uk Registered Office: Minalloy House, Regent Street, Sheffield S1 3NJ, UK VAT No. 116 8408 71, Reg’d in England No. 478098 DATASHEET 2.6.7  APPLICATION Surface wiring & buried if protected by clean sand. Suitable for use as anode cable tails, positive feed cable, negative return cable and test cable. The cable utilized in cathodic protection systems is a critical component of any cathodic protection system. The industry standard cable for direct burial is a stranded copper conductor covered with an insulation of high molecular weight polyethylene (HMWPE). The thick insulation provides both electric isolation and mechanical protection. During installation,  this cable can withstand considerable mechanical abuse without compromising the conductor . The HMWPE insulation is chemically resistant and protects against most organic and inorganic substances. STANDARDS Conductor : Stranded copper conductor conforms to ASTM Specification B-8. Insulation : Insulation is high molecular weight polyethylene conforming to ASTM D-1248, Type 1, Class A, Category 5, Grades E4 & E5. Tensile Strengths Jl, J3. Available with high density polyethylene (Types II, III, IV) Class B & C (all colors). Tests : The completed cable shall be tested in accordance with the requirements of ICEA Pub. No. S-61-402, Part 6. INSULATION THICKNESS NOMI NAL O.D. NUMBER OF STRANDS AWG  mm 2 Inches mm No Inches mm 14 2.5 0.11 2.794 7 0.299 7.59 12 4 0.11 2.794 7 0.31 7.87 10 6 0.11 2.794 7 0.34 8.64 8 10 0.11 2.794 7 0.36 9.14 6 16 0.11 2.794 7 0.41 10.41 4 25 0.11 2.794 7 0.46 11.68 2 35 0.11 2.794 7 0.52 13.21 1 45 0.125 3.175 19 0.59 14.99 1/0 50 0.125 3.175 19 0.63 16 2/0 70 0.125 3.175 19 0.67 17.02 4/0 120 0.125 3.175 19 0.78 19.82 WIRE SI ZE NOMINAL OD HMWPE CABLE DATA STANDARD SIZE AND DATA 

description

hsadiuhsad oiasdiosad oisaudpo saoi ´dsaoasud iasd ydsisahdoi a sidaso disad

Transcript of Cable Hmwpe

REVISION 1
 Venture Way, Grantham, Lincs NG31 7XS UK. Tel: +44 (0)1476 590666 Fax: +44 (0)1476 570605
Email: [email protected] Website: www.cathodic.co.uk
Registered Office: Minalloy House, Regent Street, Sheffield S1 3NJ, UK VAT No. 116 8408 71, Reg’d in England No. 478098
DATASHEET 2.6.7
 APPLICATION
Surface wiring & buried if protected by clean sand. Suitable for use as anode cable tails, positive feed cable, negative return cable and test cable.
The cable utilized in cathodic protection systems is a critical component of any cathodic protection system. The industry standard cable for direct burial is a stranded copper conductor covered with an insulation of high molecular weight  polyethylene (HMWPE). The thick insulation provides both electric isolation and mechanical protection. During installation,  this cable can withstand considerable mechanical abuse without compromising the conductor. The HMWPE insulation is chemically resistant and protects against most organic and inorganic substances.
STANDARDS
Conductor : Stranded copper conductor conforms to ASTM Specification B-8.
Insulation : Insulation is high molecular weight polyethylene conforming to ASTM D-1248, Type 1, Class A, Category 5, Grades E4 & E5. Tensile Strengths Jl, J3. Available with high density polyethylene (Types II, III, IV) Class B & C (all colors).
Tests : The completed cable shall be tested in accordance with the requirements of ICEA Pub. No. S-61-402, Part 6.
INSULATION
THICKNESS
14 2.5 0.11 2.794 7 0.299 7.59
12 4 0.11 2.794 7 0.31 7.87
10 6 0.11 2.794 7 0.34 8.64
8 10 0.11 2.794 7 0.36 9.14
6 16 0.11 2.794 7 0.41 10.41
4 25 0.11 2.794 7 0.46 11.68
2 35 0.11 2.794 7 0.52 13.21
1 45 0.125 3.175 19 0.59 14.99
1/0 50 0.125 3.175 19 0.63 16
2/0 70 0.125 3.175 19 0.67 17.02
4/0 120 0.125 3.175 19 0.78 19.82
WIRE SIZE NOMINAL OD