C N I IMPORTANT INSTRUCTIONS Lumascape USA Inc. CONTACT DETAILS LUMASCAPE USA INC. Free Call:...

5
INC. Lumascape USA Inc. 1300 Industrial Rd., Unit #19 San Carlos, CA 94070, USA T 1-(650)-595-LUMA(5862) F 1-(650)-595-5820 E [email protected] W www.lumascape.com Free Call US & Canada 1-866-695-LUMA(5862) Warning: When mounting fixtures, parts provided by Lumascape must be used.. Always check maximum wattage and lamp type before relamping. Follow lamp manufacturers instructions for lamp replacement. Failing to follow these instructions will void warranty. IMPORTANT INSTRUCTIONS For Installation LS853LED Single Colour Mains Voltage and SELV MODELS LS853LED-xxxxxxxxxx9 277 V 60Hz LS853LED-xxxxxxxxxx4 120 V 60 Hz LS853LED-xxxxxxxxxx13 12 V AC 12-24 V DC Uplight Luminaire, 20 watt Single Colour LED IP68 rated A.C.N. 010 572 773 Do not use power tools to tighten screws. Do not exert downward force on screws while not fully tightened. Do not overtighten screws. 1 Locate Fixtures Site fixture, in proximity to cabling, in gravel, soil or concrete. Use discretion in locating fixtures as glass can become very hot and may burn. 4 Mount Fixture Mount fixture such that the top lip of flange is flush with finished floor level, as shown above. 5 Open Fixture Loosen screws with allen key provided. If necessary gently lever lid out with large screwdriver. Remove components as shown. C1915 2011_10_REV-004 Lumascape Lighting Industries ©2011 www.lumascape.com o 75 CAUTION Ensure good drainage soil Æ 1 240mm (9 / ") 2 Finished floor level Depth 180mm 3 Supply Connection Connect junction box (direct burial splice box) to supply conduit as per instructions. For cable only entry connect underwater rated cable in accordance with local wiring rules. Alternatively, if ordered with 1/2"NPT conduit adaptor connect ensuring watertight seal. LS843 Fixture Finished Floor Level Supply Conduit Junction Box(Direct burial splicebox) FLUSH LID 256mm (10.08") RECESSED LID 240mm (9.45") Warning: The Luminaire should only be used complete with its protective shield (cover) 6 Target Gimbal 1. Rotate gimbal until the Aiming Mark is targeted as desired. 2 Locate and Mount Power Supply Check power supply is correct type and size for application. Refer to power supply specification. Mount power supply in suitable location. For SELV Fittings Only POWER OUTLET min 300mm Power Supply Specification 12V AC - 50/60Hz, Magnetic Transformer Only 12-24V DC - Stabilized Ripple Free Supply only Warning - The correct power supply must be used in conjunction with the Luxeon LED light sources. This will ensure the maximum life of the LED light source. - This luminaire must only be installed by a licensed electrical worker - When mounting fixtures, parts provided by Lumascape must be used. L U C US US LISTED

Transcript of C N I IMPORTANT INSTRUCTIONS Lumascape USA Inc. CONTACT DETAILS LUMASCAPE USA INC. Free Call:...

Page 1: C N I IMPORTANT INSTRUCTIONS Lumascape USA Inc. CONTACT DETAILS LUMASCAPE USA INC. Free Call: 1-866-695-LUMA(5862) LUMASCAPE CONTACT DETAILS LUMASCAPE USA INC. Created Date 10/20/2017

INC

.

Lumascape USA Inc.1300 Industrial Rd., Unit #19San Carlos, CA 94070, USAT 1-(650)-595-LUMA(5862)F 1-(650)-595-5820E [email protected] www.lumascape.com

Free Call US & Canada1-866-695-LUMA(5862)

Warning: When mounting fixtures, parts provided by Lumascape must be used.. Always check maximum wattage and lamp typebefore relamping. Follow lamp manufacturers instructions for lamp replacement. Failing to follow these instructions will void warranty.

IMPORTANT INSTRUCTIONSFor Installation LS853LED Single Colour Mains Voltage and SELV

MODELS LS853LED-xxxxxxxxxx9277 V 60Hz

LS853LED-xxxxxxxxxx4120 V 60 Hz

LS853LED-xxxxxxxxxx1312 V AC 12-24 V DC

Uplight Luminaire, 20 watt Single Colour LEDIP68 rated

A.C.N. 010 572 773

Do not use power tools to tighten screws. Do not exert downward force on screws while not fully tightened. Do not overtighten screws.

1

Locate Fixtures

Site fixture, in proximity to cabling, in gravel, soil or concrete. Use discretion in locating fixtures as glass can become very hot and may burn.

4

Mount Fixture

Mount fixture such that the top lip of flange is flush with finished floor level, as shown above.

5 Open Fixture

Loosen screws with allenkey provided. If necessarygently lever lid out withlarge screwdriver. Removecomponents as shown.

C1915 2011_10_REV-004Lumascape Lighting Industries ©2011

www.lumascape.com

o75

CAUTION

Ensure gooddrainage soil

Æ 1240mm (9 / ")2 Finishedfloor level

Depth 180mm

3

Supply Connection

Connect junction box (direct burial splice box) to supply conduit as per instructions. For cable only entry connect underwater rated cable in accordance with local wiring rules. Alternatively, if ordered with 1/2"NPT conduit adaptor connect ensuring watertight seal.

LS843Fixture

FinishedFloor Level

SupplyConduit

JunctionBox(Directburial splicebox)

FLUSH LID

256mm (10.08")

RECESSED LID

240mm (9.45")

Warning: The Luminaire should only be used complete with its protective shield (cover)

6

Target Gimbal 1.Rotate gimbal until the Aiming Mark is targeted as desired.

2

Locate and Mount Power Supply

Check power supply is correct type and size for application. Refer to power supply specification.Mount power supply in suitable location.

For SELV Fittings Only

POWER OUTLET

min

30

0m

m

Power Supply Specification

12V AC - 50/60Hz, Magnetic Transformer Only

12-24V DC - Stabilized Ripple Free Supply only

Warning

- The correct power supply must be used in conjunction with the Luxeon LED light sources. This will ensure the maximum life of the LED light source.- This luminaire must only be installed by a licensed electrical worker- When mounting fixtures, parts provided by Lumascape must be used.

LLUURCC USUS

LISTED

Page 2: C N I IMPORTANT INSTRUCTIONS Lumascape USA Inc. CONTACT DETAILS LUMASCAPE USA INC. Free Call: 1-866-695-LUMA(5862) LUMASCAPE CONTACT DETAILS LUMASCAPE USA INC. Created Date 10/20/2017

INC

.

Lumascape USA Inc.1300 Industrial Rd., Unit #19San Carlos, CA 94070, USAT 1-(650)-595-LUMA(5862)F 1-(650)-595-5820E [email protected] www.lumascape.com

Free Call US & Canada1-866-695-LUMA(5862)

Warning: When mounting fixtures, parts provided by Lumascape must be used.. Always check maximum wattage and lamp typebefore relamping. Follow lamp manufacturers instructions for lamp replacement. Failing to follow these instructions will void warranty.

IMPORTANT INSTRUCTIONSFor Installation LS853LED Single Colour Mains Voltage and SELV

MODELS LS853LED-xxxxxxxxxx9277 V 60Hz

LS853LED-xxxxxxxxxx4120 V 60 Hz

LS853LED-xxxxxxxxxx1312 V AC 12-24 V DC

Uplight Luminaire, 20 watt Single Colour LEDIP68 rated

A.C.N. 010 572 773

C1915 2011_10_REV-004Lumascape Lighting Industries ©2011

www.lumascape.com

o75

7 9 1

2

6

5

3

4

Torque Pattern

Seal Fixture.

Ensure seal and sealing surface is clean. Clean glass if necessary. Incrementally tighten lid screws using the 3mm Allen key supplied. Lumascape recommends tightening in the above Torque Pattern to 2.5 - 3 N.m.. DO NOT OVER TIGHTEN.

Warning: The Luminaire should only be used complete with its protective shield (cover)

Target Gimbal 2.Adjust gimbal tilt angle by rotating Tilt Adjust screw with Allen key supplied.Approximate angle can be read from the Tilt Angle Indicator.

o20 o20

o40

Warning

- The correct power supply must be used in conjunction with the Luxeon LED light sources. This will ensure the maximum life of the LED light source.- This luminaire must only be installed by a licensed electrical worker- When mounting fixtures, parts provided by Lumascape must be used.

LLUURCC USUS

LISTED

RunFixture

Replaceaccessoriesandallowfixturetoburnfor10-15minutestoallowanymoistureinfixturetoevaporate.

10-15MIN.

60

30

45

8

Page 3: C N I IMPORTANT INSTRUCTIONS Lumascape USA Inc. CONTACT DETAILS LUMASCAPE USA INC. Free Call: 1-866-695-LUMA(5862) LUMASCAPE CONTACT DETAILS LUMASCAPE USA INC. Created Date 10/20/2017

IMPORTANT INSTRUCTIONS

For Installation LS6052-KMODELS LS640 / LS6052-K

Mounting accessory for LS853LED

Brass Collar.

Stainless Steel Sleeve.

Bolts to anchor sleeve andarrest movement of collar inconcrete.

Styrofoam plug, (Use ifrequired. Ensure removalafter for drainage)

CAUTION; Do not pinch orcut cable beneath sleeve

Finished Floor Level tobe flush with top surfaceof brass collar.

Connector, Submersibleplug and cable. Ensure freecable reaches beyond heightof collar for fixture connection.

GENERAL ASSEMBLY

FIT LS8533LED FIXTURE When ready to install fixture;

- Destroy Foam plug.

- Assemble fixture according to LS853LED Instruction sheet.

- Remove cover plate (if located).

- Join Quick Connectors (do not dispose of cap).

5 6

1. Insert fixture body aligningholes.

2. Use screw to insert/align seal

3. Insert lid and start only,1 screw.

4. Insert screw oppositeand tighten

5. Insert and tighten allscrews.

Do not over tighten.Ensure seal/sealing surfaceis free from debris.

LID TIGHTENINGPROCEDURE

- Pour concrete. Check the topsurface of mounting collar is flushwith the finished floor level.

POUR CONCRETE

4

3

FIT SLEEVE, COLLARAND COVER PLATE

- Fit sleeve over foam plug.Ensure enough cable is in thecavity to connect to fixture.

- Position top lip of mountingcollar to be flush with finishedfloor level.

- Screw cover plate, (Availableseparately, consult yourLumascape dealer), tomounting collar if required.

2

SUPPLY CONNECTION

- Position splice box directlybeneath concrete sleeve andconnect to supply conduit.

- Punch a hole in foam plug largeenough for the connector topass through

- Pack hole in plug around thecable to ensure concretedoesn't enter the fixture cavity.

(Ensure the cap on theconnector is secure)

Layout fixture locations as required.

Use discretion in placement, fixturemay become hot and could burn.

Fixture cavity should be as above.Ensure gravel or similar mediumforms the bottom of cavity toallow drainage.

HOLE DETAIL -SECTION VIEW

1

430M

M(1

’ 5“)

MIN

FINISHEDFLOORLEVEL

GRAVEL

HOLE265MM

(10 / “)1

2

CAUTION - This Product Must Only Be Installed/fitted By A Licensed Electrical WorkerNOTE - As per 2002 NEC Section 300.50, the STOOW cord must be at least 450mm (18in)below a minimum 2 inch thick concrete slab

C1615US - 2006_07_REV001

Factory supplied directburial splice box,epoxy sealed entry. Ensurelid and gasket are replaced.Use 3M brand product#4442 Re-Enterable Gelafter connections havebeen made to ensurewater-proofing.Refer Lumascapeinstructionsheet "For Installation ofLS640/LS6052-K DirectBurial Splice Box” forconnection information. Cable length 900mm (36in)

LURC US

COVERPLATE

MOUNTINGCOLLAR

STAINLESSSTEELSLEEVE

FINISHEDFLOORLEVEL

CONCRETE

FINISHEDFLOORLEVEL

LS853LEDFIXTURE

CONNECTOR

FOAMPLUG

CABLE/DIRECTBURIALSPLICE BOXASSEMBLY

SUPPLYCONDUIT

FOAMPLUG

FINISHEDFLOORLEVEL

SPLICEBOX

PAGE 1

US Head Office

Telephone

Fax

1300 Industrial Rd., Unit #19San Carlos, CA 94070

USA

1-(650)-595-LUMA(5862)

1-(650)-595-5820

Free Call

www.lumascape.com

(US & Canada)

1-866-695-LUMA(5862)

LUMASCAPE USA INC.

IN

C.

Page 4: C N I IMPORTANT INSTRUCTIONS Lumascape USA Inc. CONTACT DETAILS LUMASCAPE USA INC. Free Call: 1-866-695-LUMA(5862) LUMASCAPE CONTACT DETAILS LUMASCAPE USA INC. Created Date 10/20/2017

DEPTH 240mm

Ensure gooddrainage soil

IMPORTANT INSTRUCTIONS

For Installation LS640

5 64

321

Layout fixture locations asrequired.

Use discretion in placement,fixture may become hot andcould burn.

Fixture cavity requirements areas shown above.

FINISHEDFLOORLEVEL

CAVITY240MM

(9 / )1

2"

DE

PT

H

CAVITY REQUIREMENTS

TILE

GRATE

DECKING

Mount collar securely asrequired in floor media.

MOUNT COLLAR

If installation of fixture intomounting collar is to be delayedwe recommend the installation ofa cover plate. These are availablefrom Lumascape, please consultyour dealer,

TEMPORARY COVER PLATE

SUPPLY CONNECTION

Insert fixture into mounting collaralligning holes in the flange withtapped holes in the collar

MOUNT FIXTURE LAMP, TEST, SEAL.

Complete installation of fixture by inserting lamp, testing and sealing, (As per Instruction6 over.) according to the LS853LED installation instruction sheet.

CAUTION - This Product Must Only Be Installed/fitted By A Licensed Electrical Worker

LURC US

If fixture is ordered with directburial splice box cable entry,connect according to directburial splice box installationinstructions and local wiringrules.

Alternatively, if supplied with1/2"NPT adaptor connect inaccordance with local wiringrules and ensure a watertightseal.

US Head Office

Telephone

Fax

1300 Industrial Rd., Unit #19San Carlos, CA 94070

USA

1-(650)-595-LUMA(5862)

1-(650)-595-5820

Free Call

www.lumascape.com

(US & Canada)

1-866-695-LUMA(5862)

LUMASCAPE USA INC.

IN

C.

SUPPLYCONDUIT

DIRECTBURIALSPLICEBOX

FINISHEDFLOORLEVEL

FIXTURE

MODELS LS640 / LS6052-KMounting accessory for LS853LED

C1615US - 2006_07_REV001

PAGE 2

Page 5: C N I IMPORTANT INSTRUCTIONS Lumascape USA Inc. CONTACT DETAILS LUMASCAPE USA INC. Free Call: 1-866-695-LUMA(5862) LUMASCAPE CONTACT DETAILS LUMASCAPE USA INC. Created Date 10/20/2017

www.lumascape.com

IMPORTANT INSTRUCTIONS

For Adjusting/Aiming of Refractor LensMODELS LS343-22 * ** ** XT ** * * Wide (VN,MH)

LS343-22 * ** ** XP ** * * Ultra wide (VN,MH)LS343-22 * ** ** XQ ** * * Very Narrow (VN,MH)LS343-22 * ** ** XL ** * * (W, CFL)

C898US - 2006_07_REV001

IMPORTANT

Ensure that glare shieldis

fitted the correct way up asshown. Glare shield shouldseat neatly into fixture.

, ifsupplied - VN models only,

For Very Narrow Refractors -

GlareShield

RefractorSpacer

Lens

Reflector

SecondaryGlass

3

Carefully remove lens (andsecondary glass, glareshield) and tighten grubscrew. Apply gentledownward pressure toblack spacer ring as screwis tightened.

Lock reflector

4

Replace lens (andsecondary glass, glareshield) and outer coverassembly and resealfixture.

Replace lens and lid

Note

Additional filters, (137mm)can be added to the fixtureby retaining beneath springclips on the top of thesecondary glass holder.

Additional filter

1

Loosen screws with allenkey provided. If necessarygently lever lid out withlarge screwdriver. Removecomponents as shown.Loosen grub screw.Replace components.

Open fixture and Unlock

UW & VNMetal HalideOnly

VN Only

2

Turn fixture on. Rotateblack spacer ring and lensuntil required result isachieved. Turn fixture off.

Aim fixture optics

IMPORTANT INSTRUCTIONS

For Adjusting/Aiming of Refractor Lens

C898US - 2006_07_REV001

IMPORTANT

Ensure that glare shieldis

fitted the correct way up asshown. Glare shield shouldseat neatly into fixture.

, ifsupplied - VN models only,

For Very Narrow Refractors -

GlareShield

RefractorSpacer

Lens

Reflector

SecondaryGlass

3

Carefully remove lens (andsecondary glass, glareshield) and tighten grubscrew. Apply gentledownward pressure toblack spacer ring as screwis tightened.

Lock reflector

4

Replace lens (andsecondary glass, glareshield) and outer coverassembly and resealfixture.

Replace lens and lid

Note

Additional filters, (137mm)can be added to the fixtureby retaining beneath springclips on the top of thesecondary glass holder.

Additional filter

1

Loosen screws with allenkey provided. If necessarygently lever lid out withlarge screwdriver. Removecomponents as shown.Loosen grub screw.Replace components.

Open fixture and Unlock

UW & VNMetal HalideOnly

VN Only

2

Turn fixture on. Rotateblack spacer ring and lensuntil required result isachieved. Turn fixture off.

Aim fixture optics

www.lumascape.com

MODELS LS343-22 * ** ** XT ** * * Wide (VN,MH)LS343-22 * ** ** XP ** * * Ultra wide (VN,MH)LS343-22 * ** ** XQ ** * * Very Narrow (VN,MH)LS343-22 * ** ** XL ** * * (W, CFL)

Free Call:

1-866-695-LUMA(5862)Ph: 1-(650)-595-LUMA(5862)

Fax: 1-(650)-595-5820

1300 Industrial Rd., Unit #19

San Carlos, CA 94070, USA

LUMASCAPE CONTACT DETAILS

LUMASCAPE USA INC.Free Call:

1-866-695-LUMA(5862)Ph: 1-(650)-595-LUMA(5862)

Fax: 1-(650)-595-5820

1300 Industrial Rd., Unit #19

San Carlos, CA 94070, USA

LUMASCAPE CONTACT DETAILS

LUMASCAPE USA INC.