By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

63
Super Therm® By: Mario Martinez President Pro Green Roof Systems and Construction, LLC

Transcript of By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

Page 1: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

Super Therm®

By: Mario Martinez

President

Pro Green Roof Systems and Construction, LLC

Page 2: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

What is Super Therm® ?

Page 3: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

Super Therm® is a thermal barrier ceramic coatingSuper Therm® is a ceramic based, water borne,

thermal barrier coating that is designed to block and reflect heat that decreases energy and maintenance cost. As the only ceramic coating developed in cooperation with NASA, Super Therm® is the most effective, durable, and long lasting ceramic coating on the market.

Page 4: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

What makes Super Therm® unique?

Page 5: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

Average Energy Savings

30%

Page 6: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.
Page 7: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

Heat Sources from the SunTypes of heat Infrared

Visible LightUltraviolet

3%

57%40%

Page 8: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

How much Infrared, Visible Light, and Ultraviolet heat does Super Therm® block?

Page 9: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

Percentage of heat that is blocked by Super Therm®

Infrare

d

99.5%

Visible Light 92%

Ultraviolet 99%

Page 10: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

Definitions• Solar Reflectivity - Amount of incoming solar energy a

material reflects (usually in a %)• Emissivity – Amount of energy a material emits due to its

own heat and temperature (usually in %)

Sun

Roof

Reflected Emitted

Page 11: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

• Fear of glare• Super Therm® produces diffused reflections, not secular reflections

Roof

Secular

Diffuse

Page 12: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

Nippon Paint Factory Roof Insulation

Page 13: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

Residential Home in Little Rock, Arkansas

Heat Loss Captured by Infrared Camera AFTER Application of

Super Therm®

Heat Loss Captured by Infrared Camera BEFORE

Application of Super Therm®

Page 14: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

Why is Super Therm® preferred over other products?

Page 15: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

Super Therm® has a unique ceramic composition

• Blend of four different ceramics that block all windows of heat transfer.

• Other ceramic coatings only contain glass hollow spheres that reflect visual light when clean but absorb and transfer other windows of heat.

• Only ceramic coating rated as an insulator by BOCA (Us Building Code)

• Includes various resins, including urethanes for durability and longevity

Page 16: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

Protection from the Elements

Rain Moisture Humidity

Page 17: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

Reduces sound waves by 68%

Super Therm™

68% reduction

Page 18: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

Super Therm® is rated as a true insulator by BOCA (US Building Code)

Page 19: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

R19 equivalent rating

10 mils dry

Super Therm™ 6” – 8”

Page 20: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

ASHRAE 90.1 Code ComplianceTESTING REQUIRED TO PROVE THE “R” VALUE

A. ASTM C 236-89 “ Standard Test Method for Steady-State Thermal Performance of Building Assemblies by Means of a Guarded Hot Box.”

B. ASTM 1269 “Differential Scanning Calorimeter”

ASTM E 1461-92 “Thermal Diffusivity.”

Super Therm® has a “U” ( Thermal Flow) Value of 0.052.

Super Therm® is (1/RE) = 0.052 Thermal Flow. ASHRAE 90.1 Compliance Varrience cannot exceed 0.061 for Thermal Flow.

Super Therm® falls within the ASHRAE 90.1 Compliance Rating and is acceptable.

Page 21: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

Super Therm® has a Class A Fire Rating

Super Therm™

Page 22: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

Super Therm® prevents mold and mildew

Page 23: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

Super Therm® is USDA Approved

Page 24: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

Super Therm® is a certified water barrier(ASTM D 7088, ASTM D 6904)

Super Therm™

Page 25: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

Super Therm® is Environmentally friendly(24 grams of VOC)

Page 26: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

Super Therm® has a very long life expectancy

Page 27: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

Super Therm® has extraordinary e l a s t i c i t y

Passed ASTM E1737

Super Therm™

Page 28: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

Where can Super Therm® be used?

Page 29: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

Roof Insulation

Page 30: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

Concrete Insulation

Walls Floors

Page 31: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

Sound Proofing

Vending Machines Elevator Shafts

Page 32: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

Air Conditioning & Ducting

AC Units AC Ducting

Page 33: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

Companies that have used Super Therm®

Page 34: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.
Page 35: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

Customers who have used Super Therm®

Page 36: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

Nissan Motor Co. Ltd.Yokahama, Japan

200,000 sq. Meters

Before After

Page 37: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

Chicago Bridge & Iron CompanyBeaumont, TexasBefore Super

Therm® Application Saw Tooth

Section Built 1937

After Super

Therm® Applicatio

n

187,000 Sq.Ft. of Metal and 82,000 Sq.Ft. of Tar & Gravel

Page 38: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

Tucson International AirportSuper Therm® was applied toCentral PlantWest ConcourseEast ConcourseWash Bays

Note:A power wash and thorough

cleaning was performed on all roof tops prior to application

Page 39: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

Tucson International Airport

August 2009 Savings = $22,144

Chris Wilt - Senior Director Facility Development

Page 40: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

Circle K in Tucson (before Super Therm®)

Page 41: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

Circle K in Tucson (after Super Therm®)

Page 42: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

TRUMP INTERNATIONAL FT. LAUDERDALE, FL

Super Therm® was applied toConcrete ceiling of lobbyConcrete ceiling of parking

structure under air conditioned space

Page 43: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

SANTA ROSA DUNES PENSACOLA, FL

Page 44: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

Bel-Air Condos in Austin, TexasSPI iStucco™ System

Thermal Scan BEFORE iStucco™ System

Thermal Scan AFTER iStucco ™ System

Page 45: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.
Page 46: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

iStucco System BEFORE

Page 47: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

Ceramic iStucco Application

Page 48: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

iStucco After Super Therm®

Page 49: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

Frito Lay Trailer, KY Trailer

Page 50: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

Irvington Elementary School, KY

Page 51: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

Apartent Buildings And HotelIn Munich Germany

Page 52: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

Residential HomeLas Vegas, Nevada

Page 53: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

Testing, Certification and Endorsements of Super Therm

Page 54: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

ENERGY STAR Program

Approved and accepted with Energy Star for energy savingsASTM E 903-96 Reflectivity = 80%Only 1% reduction in reflectivity over 3 years (3% over 10 years

Page 55: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

ASTM TestingB 117/D 1654 450 Hour Salt Spray (Fog) – PassedC 177 thermal conductivity testing – PassedC 236 (C236-89(1993)el) – Passed, our performed

fiberglass by 148%.Standard Test Method for Steady-State Thermal

Performance of Building Assemblies by means of Guarded Hot Box. Testing for measuring R-values.

C 411 High – Temperature Surface Performance – PassedD 412 Tensile strength – Passed

.041 thickness = 13,248 psi

Page 56: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

ASTM Testing Continued…..D 522 – Passed

Resistance to cracking on metal or rubber type materials. 1” (25mm)bend. ¼”(96mm)bend

D 1653 Water Vapor Permeability – PassedD 1654 Salt spray (fog/weathering) – Passed – 2000 hoursD 3273-82T D 3274 – Passed

Resistance to fungal growth or soil and dirt accumulation on paint film. Excellent (8 out of 9)

D 4060 Abrasion Resistance – PassedE 84 Flame Spread / Smoke Developed – Passed

Class “A” Rating (or Class “1” or Class “I”)

Page 57: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

ASTM Testing Continued…..

E84-89a Flame spread / Smoke Developed – Passed – “0” developmentFlame Index “0”. Smoke Index “0”

E96 water vapor transmission – Passed – less than .01E 96 water vapor transmission – Passed – less than .01E 903-96 Reflectance – PassedE 119 Structural Steel Fire curve – Passed – 25 minutesE 1269 Thermal penetration through a substrate by differential

scanning calorimeter – Passed – blocking 99% of heat BTU conduction – TPRL

Page 58: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

ASTM Testing Continued…..E 1461-92 Laser flash technique conductivity

diffusivity – PassedVTEC Laboratories review of test results – Letter

stating RE19TPRL lab test results show a bare metal plate

allowing 367.20 BTU heat conduction. SUPER THERM® coated on metal plate allowed only 3.99 BTU heat gain. A 99% reduction in heat transfer after applying only one coat of SUPER THERM ® on test plate.

G53 exposure to UV, elevated temperature and humidity - Passed

Page 59: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

ICC Approval (International Code Council) 0104

Passed – ID #21-25Council that formally consolidates approvals for BOCA (Building Officials Code Administrators)

Section 723.2 Exposed installations, Thermal insulation

Section 723.3 Concealed installations, Thermal insulation

Section 803.2 Classification, Interior finish1998 International Mechanical Code

Section 604.3 Coverings and Linings, Insulation

Page 60: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

ICBO (International Conference of Building Officials)

Passed ASTM E 84 For Flame SpreadPassed ASTM C 411 for High Temperature for

Surface PerformancePassed ASTM C 177 for Thermal Conductivity

(*SUPER THERM Specific)

Page 61: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

NASA Testing

NHB 8060.1B/C Test 1 Flammability testing – Passed

“0” Burn, Class “A” rating – PassedNHB 8060.1C, Test 7 Toxic Off gassing –

Passed“K” no Toxic off gassing – Passed“K” Rating for toxicity – PassedTests performed at Marshall Space Flight

Center

Page 62: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

Key EndorsementsUSDAPassed

Environmentally safe and safe for use around animalsApproved for incidental food contactLetter of Written Certification as Accepted by USDA from

Manufacturer

Underwriters Laboratory Inc. Approved

Factory Mutual Approval Passed - E - 108 Flame Spread over pitched roofing Tested and Approved for Roofing and all other Applications

California Cool Roof Program California Building Energy Efficiency Standards

Florida Cool Roof Rebate Program State approval for energy rebate

Page 63: By: Mario Martinez President Pro Green Roof Systems and Construction, LLC.

Pro Green Contact Information

Mario Martinez – (505) 780-1756 Dale Hatch – (480) 225-6835

[email protected] [email protected]

Andre Bluth – (623) 695-2406 Jason McDonald – (615) 878-4357

[email protected] [email protected]

Mark Cordova – (602) 510-0739 Luis Villalobos – (915) 329-5660

[email protected] [email protected]