Unit - 2
BUILDING SERVICES – I
![Page 2: Building Services Cspa l ecture 3](https://reader038.fdocuments.net/reader038/viewer/2022103000/555722f2d8b42a320c8b4882/html5/thumbnails/2.jpg)
SOURCES OF WATER: SURFACE SOURCES:1. Streams2. Lakes3. Ponds4. Rivers5. Reservoirs6. Stored rain water and
cisterns
GROUND SOURCES:1. Springs2. Wells
![Page 3: Building Services Cspa l ecture 3](https://reader038.fdocuments.net/reader038/viewer/2022103000/555722f2d8b42a320c8b4882/html5/thumbnails/3.jpg)
DISTRIBUTION SYSTEM:
Pressure in pipe line is necessary, which should force the water to reach at every place.
Distribution system are classified as :-
For efficient distribution it is required that water should reach to every consumer with required rate of flow.
Pumping
System
Gravity
System
Dual
System
![Page 4: Building Services Cspa l ecture 3](https://reader038.fdocuments.net/reader038/viewer/2022103000/555722f2d8b42a320c8b4882/html5/thumbnails/4.jpg)
GRAVITY SYSTEM
• When some lake, river, reservoir sufficiently high above the city area is available.
• Water flows in mains due to gravitational pull, no pumping is required.
![Page 5: Building Services Cspa l ecture 3](https://reader038.fdocuments.net/reader038/viewer/2022103000/555722f2d8b42a320c8b4882/html5/thumbnails/5.jpg)
PUMPING SYSTEM
• Pressure maintained in the pipe line is by pump
• Water is directly pumped in the mains
• Number of pumps are required to work at different time & pressure rate in a day
• If power fails the whole supply will be stopped
Pressure
Water Mains
![Page 6: Building Services Cspa l ecture 3](https://reader038.fdocuments.net/reader038/viewer/2022103000/555722f2d8b42a320c8b4882/html5/thumbnails/6.jpg)
DUAL SYSTEM
• when less water demand - water is stored in elevated reservoir• With increase in water demand – water comes from both pumping
station as well as reservoir
• During power failure and fire fighting water stored in reservoir can be used
• Also known as combined gravity and pumping system.
• Pump is connected to the mains as well as to the elevated reservoir
• More reliable and economic
• Require uniform rate of pumping
![Page 7: Building Services Cspa l ecture 3](https://reader038.fdocuments.net/reader038/viewer/2022103000/555722f2d8b42a320c8b4882/html5/thumbnails/7.jpg)
PLUMBING
• refers to a system of pipes and fixtures installed in a building for the
distribution of potable water and the removal of waterborne wastes.
• Is the art and technique of installing pipes, fixtures & other
apparatuses in buildings & for bringing the water supply, liquids, &
removing them;
• from the Latin plumbum for lead as pipes were once made from lead.
![Page 8: Building Services Cspa l ecture 3](https://reader038.fdocuments.net/reader038/viewer/2022103000/555722f2d8b42a320c8b4882/html5/thumbnails/8.jpg)
• Also fuel gas piping; water heaters and vents for same.
PLUMBING SYSTEM
DRAINAGE PIPESUPPLY PIPE FIXTURE
• System includes all potable water supply and distribution pipes, all plumbing fixtures and traps;
• all sanitary and storm drainage systems; eg. roof drains and down spouts
• and all building drains and sewers, including the joints and connections
![Page 9: Building Services Cspa l ecture 3](https://reader038.fdocuments.net/reader038/viewer/2022103000/555722f2d8b42a320c8b4882/html5/thumbnails/9.jpg)
PLUMBING CYLE
![Page 10: Building Services Cspa l ecture 3](https://reader038.fdocuments.net/reader038/viewer/2022103000/555722f2d8b42a320c8b4882/html5/thumbnails/10.jpg)
Water Supply and Distribution System
Definition
• Carries water from the water source, street main or to the building and to
various points in the building at which water is used.
Water Supply Systems
• Hot water system
• Cold water system
Cold water system :
• Cold water system provide water for the following purposes. ▫ Drinking purpose ▫ Cooking purpose ▫ Sanitary purpose ▫ Washing purpose ▫ Gardening
![Page 11: Building Services Cspa l ecture 3](https://reader038.fdocuments.net/reader038/viewer/2022103000/555722f2d8b42a320c8b4882/html5/thumbnails/11.jpg)
Types Of Cold Water System
Two Types
1. Direct system
2. Indirect system
Direct Water Supply System
• Water is supplied direct from mains to fixtures
Indirect Water Supply System
• Water going to overhead tank and then the water is supplied to different floors by gravity
![Page 12: Building Services Cspa l ecture 3](https://reader038.fdocuments.net/reader038/viewer/2022103000/555722f2d8b42a320c8b4882/html5/thumbnails/12.jpg)
– Fresh Drinking water may be obtained at any
point
Advantages:
– If there is a mains burst there is no store of water
Disadvantages:
Direct Water Supply System
– saving in pipe work especially in multistory
buildings.
– This is due to cold water distribution pipe from
the cistern being omitted
– There is a danger of foul water from the sanitary fittings being
siphoned back into the main water
– During peak periods there is a tendency for the lowering of pressure
![Page 13: Building Services Cspa l ecture 3](https://reader038.fdocuments.net/reader038/viewer/2022103000/555722f2d8b42a320c8b4882/html5/thumbnails/13.jpg)
– In case of an interruption in the mains
supply there is an adequate store of
water
Advantages:
– Fresh Drinking water is only available at the kitchen sink (or single
point)
Disadvantages:
Indirect Water Supply System
– There is no risk of back siphon age
with this system
– There is no tendency of pipe bursting due
to the low pressure in the pipe work
– Longer pipe runs are required
– A larger storage cistern is necessary
![Page 14: Building Services Cspa l ecture 3](https://reader038.fdocuments.net/reader038/viewer/2022103000/555722f2d8b42a320c8b4882/html5/thumbnails/14.jpg)
PARTS OF WATER DISTRIBUTION SYSTEM
SERVICE PIPE
The pipe from the water main or other source of potable water supply to the water distribution system of the building served.
DISTRIBUTION PIPE/ SUPPLY PIPE
A pipe within the structure or on the premises which conveys water from the water service pipe to the point of utilization.
RISER
A water supply pipe that extends one full story or more to convey water to branches or to a group of fixtures.
FIXTURE BRANCH
The water supply pipe between the fixture supply pipe & the water distributing pipe.
FIXTURE SUPPLY
A water supply pipe connecting the fixture with the fixture branch.
![Page 15: Building Services Cspa l ecture 3](https://reader038.fdocuments.net/reader038/viewer/2022103000/555722f2d8b42a320c8b4882/html5/thumbnails/15.jpg)
SERVICE PIPE
DISTRIBUTION PIPE/ SUPPLY PIPE
RISER
FIXTURE BRANCH
FIXTURE SUPPLY
![Page 16: Building Services Cspa l ecture 3](https://reader038.fdocuments.net/reader038/viewer/2022103000/555722f2d8b42a320c8b4882/html5/thumbnails/16.jpg)
TYPES OF FITTINGS/PLUMBING FIXTURES IN BRIEF
![Page 17: Building Services Cspa l ecture 3](https://reader038.fdocuments.net/reader038/viewer/2022103000/555722f2d8b42a320c8b4882/html5/thumbnails/17.jpg)
TYPES OF PIPES:
1.Plastic pipes:
a.LDPE (Low Density polyethylene)
b.HDPE (High Density polyethylene)
c.PVC
2.Galvanised iron (GI) pipes
3.Asbestos Pipes
4.Cast iron (CI) Pipes
5.RCC Spun pipes
6.Copper pipes
![Page 18: Building Services Cspa l ecture 3](https://reader038.fdocuments.net/reader038/viewer/2022103000/555722f2d8b42a320c8b4882/html5/thumbnails/18.jpg)
PLASTIC PIPES
LDPE PIPES
HDPE PIPES
PVC PIPES
![Page 19: Building Services Cspa l ecture 3](https://reader038.fdocuments.net/reader038/viewer/2022103000/555722f2d8b42a320c8b4882/html5/thumbnails/19.jpg)
GALVANISED IRON (G. I . PIPES)
![Page 20: Building Services Cspa l ecture 3](https://reader038.fdocuments.net/reader038/viewer/2022103000/555722f2d8b42a320c8b4882/html5/thumbnails/20.jpg)
CAST IRON PIPES RCC SPUN PIPES
COPPER PIPES
![Page 21: Building Services Cspa l ecture 3](https://reader038.fdocuments.net/reader038/viewer/2022103000/555722f2d8b42a320c8b4882/html5/thumbnails/21.jpg)
LEAD PIPES
![Page 22: Building Services Cspa l ecture 3](https://reader038.fdocuments.net/reader038/viewer/2022103000/555722f2d8b42a320c8b4882/html5/thumbnails/22.jpg)
JOINTS
![Page 23: Building Services Cspa l ecture 3](https://reader038.fdocuments.net/reader038/viewer/2022103000/555722f2d8b42a320c8b4882/html5/thumbnails/23.jpg)
JOINTS
![Page 24: Building Services Cspa l ecture 3](https://reader038.fdocuments.net/reader038/viewer/2022103000/555722f2d8b42a320c8b4882/html5/thumbnails/24.jpg)
• Valves are the devices used for controlling the flow of liquid in a pipe line.
• With the use of Valve any section of pipe line can be isolated for the purpose of inspection, repairs etc.
• Different types of valves are:
1.LINE VALVES - Sluice Valves - Globe Valves2.SCOUR VALVES3.AIR VALVES4.RELIEF VALVES5.REFLUX VALVES6.FLOAT VALVES7. FIRE HYDRANTS
VALVES
8.TAPS & STOP COCKS
![Page 25: Building Services Cspa l ecture 3](https://reader038.fdocuments.net/reader038/viewer/2022103000/555722f2d8b42a320c8b4882/html5/thumbnails/25.jpg)
GLOBE VALVE
SLUICE VALVE
![Page 26: Building Services Cspa l ecture 3](https://reader038.fdocuments.net/reader038/viewer/2022103000/555722f2d8b42a320c8b4882/html5/thumbnails/26.jpg)
AIR VALVE
FLOAT
LEVER
RELIEF VALVE
FLOAT VALVE
![Page 27: Building Services Cspa l ecture 3](https://reader038.fdocuments.net/reader038/viewer/2022103000/555722f2d8b42a320c8b4882/html5/thumbnails/27.jpg)
GATE VALVE
![Page 28: Building Services Cspa l ecture 3](https://reader038.fdocuments.net/reader038/viewer/2022103000/555722f2d8b42a320c8b4882/html5/thumbnails/28.jpg)
TAP OR BIB COCK
• Taps are provided at the ends of
the water pipe to draw-off water
from the pipe.
• It is normally a screw down type &
opens in an anticlockwise
direction.
• The bib cock may be a push type
which operates automatically &
normally used in public places.
![Page 29: Building Services Cspa l ecture 3](https://reader038.fdocuments.net/reader038/viewer/2022103000/555722f2d8b42a320c8b4882/html5/thumbnails/29.jpg)
STOP COCK
![Page 30: Building Services Cspa l ecture 3](https://reader038.fdocuments.net/reader038/viewer/2022103000/555722f2d8b42a320c8b4882/html5/thumbnails/30.jpg)
STOP TAP