Building America Special Research Project: High-R ... · Foundations Case Study Analysis Building...
Transcript of Building America Special Research Project: High-R ... · Foundations Case Study Analysis Building...
1
Building America Special Research Project: High-R Foundations Case Study Analysis
Building America Report - 1003 20 August 2010 Jonathan Smegal and John Straube
Abstract:
Many concerns, including the rising cost of energy, climate change concerns, and demands for increased comfort, have lead to the desire for increased insulation levels in many new and existing buildings. Building codes are improving to require higher levels of thermal control than ever before for new construction. This report considers a number of promising foundation and basement insulation strategies that can meet the requirement for better thermal control in colder climates while enhancing moisture control, health, and comfort.
building science.com © 2010 Building Science Press All rights of reproduction in any form reserved.
BuildingAmericaSpecialResearchProject
HighRFoundationsCaseStudyAnalysis20100820
JonathanSmegalMAScJohnStraube,PhD,P.Eng
BuildingScienceCorporation30ForestStreet
Somerville,MA02143
www.buildingscience.com
Building Science Corporation 1 www.buildingscience.com 30 Forest St. Somerville, MA 02143
TableofContentsA. Introduction ...........................................................................................................................................................................................4
1.Objective...................................................................................................................................................................................................4
2.Scope ..........................................................................................................................................................................................................5
3.Approach..................................................................................................................................................................................................5
B. Analysis ....................................................................................................................................................................................................5
1.Wallassembliesreviewed ................................................................................................................................................................5
2.AnalysisCriteria....................................................................................................................................................................................5
2.1ThermalControlandHeatFlowAnalysis ..........................................................................................................................7
2.2HygrothermalAnalysis ........................................................................................................................................................... 16
2.3EnclosureDurability ................................................................................................................................................................ 41
2.4Buildability................................................................................................................................................................................... 41
2.5MaterialUse ................................................................................................................................................................................. 41
2.6Cost 42
2.7OtherConsiderations............................................................................................................................................................... 42
C. Results ................................................................................................................................................................................................... 43
1.Case1:UninsulatedFoundationWallsandSlab................................................................................................................. 43
1.1ThermalControl......................................................................................................................................................................... 43
1.2MoistureControl........................................................................................................................................................................ 43
1.3ConstructabilityandCost....................................................................................................................................................... 44
1.4OtherConsiderations............................................................................................................................................................... 44
2.Case2:CodeminimumR10continuousinsulation........................................................................................................... 45
2.1ThermalControl......................................................................................................................................................................... 45
2.2MoistureControl........................................................................................................................................................................ 45
2.3ConstructabilityandCost....................................................................................................................................................... 46
2.4OtherConsiderations............................................................................................................................................................... 46
3.Case3:R13fiberglassbattina2x4framedwall ................................................................................................................ 47
3.1ThermalControl......................................................................................................................................................................... 47
3.2MoistureControl........................................................................................................................................................................ 47
3.3ConstructabilityandCost....................................................................................................................................................... 48
3.4OtherConsiderations............................................................................................................................................................... 48
4.Case4:1”XPS,2x4woodframedwallwithfibreglassbatt ........................................................................................... 49
4.1ThermalControl......................................................................................................................................................................... 49
4.2MoistureControl........................................................................................................................................................................ 49
4.3ConstructabilityandCost....................................................................................................................................................... 50
Building Science Corporation 2 www.buildingscience.com 30 Forest St. Somerville, MA 02143
4.4OtherConsiderations............................................................................................................................................................... 50
5.Case5:2”XPS,2”foilfacedpolyisocyanurate ..................................................................................................................... 51
5.1ThermalControl......................................................................................................................................................................... 51
5.2MoistureControl........................................................................................................................................................................ 51
5.3ConstructabilityandCost....................................................................................................................................................... 52
5.4OtherConsiderations............................................................................................................................................................... 52
6.Case6:3.5”2.0pcfclosedcellspraypolyurethanefoam ............................................................................................... 53
6.1ThermalControl......................................................................................................................................................................... 53
6.2MoistureControl........................................................................................................................................................................ 53
6.3ConstructabilityandCost....................................................................................................................................................... 54
6.4OtherConsiderations............................................................................................................................................................... 54
7.Case7:6”0.5pcfopencellsprayfoam................................................................................................................................... 55
7.1ThermalControl......................................................................................................................................................................... 55
7.2MoistureControl........................................................................................................................................................................ 56
7.3ConstructabilityandCost....................................................................................................................................................... 56
7.4OtherConsiderations............................................................................................................................................................... 56
8.Case8:2”XPS,2x4framingwithfibreglassbatt ................................................................................................................ 57
8.1ThermalControl......................................................................................................................................................................... 57
8.2MoistureControl........................................................................................................................................................................ 57
8.3ConstructabilityandCost....................................................................................................................................................... 57
8.4OtherConsiderations............................................................................................................................................................... 58
9.Case9:2”Polyisocyanurateinsulation,2x4framingwithcellulose.......................................................................... 58
9.1ThermalControl......................................................................................................................................................................... 58
9.2MoistureControl........................................................................................................................................................................ 58
9.3ConstructabilityandCost....................................................................................................................................................... 59
9.4OtherConsiderations............................................................................................................................................................... 59
10.Case10:6”0.5pcfsprayfoamwith2x4framingoffset2.5”fromconcrete ........................................................ 59
10.1ThermalControl ...................................................................................................................................................................... 59
10.2MoistureControl ..................................................................................................................................................................... 59
10.3ConstructabilityandCost .................................................................................................................................................... 60
10.4OtherConsiderations ............................................................................................................................................................ 60
11.Case11:4”XPSinsulationontheexterioroffoundationwall................................................................................... 60
11.1ThermalControl ...................................................................................................................................................................... 60
11.2MoistureControl ..................................................................................................................................................................... 61
11.3ConstructabilityandCost .................................................................................................................................................... 61
11.4OtherConsiderations ............................................................................................................................................................ 61
12.Case12:4”XPSinsulationinthecenteroffoundationwall ....................................................................................... 61
Building Science Corporation 3 www.buildingscience.com 30 Forest St. Somerville, MA 02143
12.1ThermalControl ...................................................................................................................................................................... 62
12.2MoistureControl ..................................................................................................................................................................... 62
12.3ConstructabilityandCost .................................................................................................................................................... 62
12.4OtherConsiderations ............................................................................................................................................................ 62
13.Case13:InsulatedConcreteForms,2”XPSoninteriorandexterior ..................................................................... 63
13.1ThermalControl ...................................................................................................................................................................... 63
13.2MoistureControl ..................................................................................................................................................................... 63
13.3ConstructabilityandCost .................................................................................................................................................... 63
13.4OtherConsiderations ............................................................................................................................................................ 64
14.Case14:2”XPS,2x6framingwithfibreglassbatt ........................................................................................................... 64
14.1ThermalControl ...................................................................................................................................................................... 64
14.2MoistureControl ..................................................................................................................................................................... 64
14.3ConstructabilityandCost .................................................................................................................................................... 65
14.4OtherConsiderations ............................................................................................................................................................ 65
15.Case15:4”PIC,2x6framingwithfibreglassbatt............................................................................................................ 65
15.1ThermalControl ...................................................................................................................................................................... 65
15.2MoistureControl ..................................................................................................................................................................... 65
15.3ConstructabilityandCost .................................................................................................................................................... 66
15.4OtherConsiderations ............................................................................................................................................................ 66
D. Conclusions.......................................................................................................................................................................................... 67
E. FutureWork........................................................................................................................................................................................ 69
F. WorksCited ......................................................................................................................................................................................... 70
Building Science Corporation 4 www.buildingscience.com 30 Forest St. Somerville, MA 02143
A. Introduction
Manyconcerns,includingtherisingcostofenergy,climatechangeconcerns,anddemandsforincreasedcomfort,haveleadtothedesireforincreasedinsulationlevelsinmanynewandexistingbuildings.Buildingcodesareimprovingtorequirehigherlevelsofthermalcontrolthaneverbeforefornewconstruction.Thisreportconsidersanumberofpromisingfoundationandbasementinsulationstrategiesthatcanmeettherequirementforbetterthermalcontrolincolderclimateswhileenhancingmoisturecontrol,health,andcomfort.
The2009IRC(TableN1102.1)and2009IECC(Table402.27)requirebasementsinDOEclimatezonesfourandgreatertorequireacontinuouslayerofR10insulationorR13inaframedwall.HighRbasements,forcoldclimates,inthisreportarewallsthatapproachorexceedatrueR‐valueofR20.Inawarmerclimate,thatdoesnotrequirebasementinsulation,high‐Rmaybeconsideredless.
Basementsarestereotypicallycool,damp,mustysmellingareasofthebuildingthatwerehistoricallyunfinished,unoccupiedandusedmostlyasstorage.Moreandmoreoften,peoplearefinishingtheirbasementstoincreasethelivingenvironmentandfrequentlythebasementistransformedintoamediaroom,bedroom,orextralivingroom.Thesenewenvironmentsrequiregreatercontrolofbothheatandmoisturetoprovideahealthylivingenvironmentwithminimalrisktoequipmentandfinishes.
Asuccessfulfoundationwillperformthefollowingtasks
• Holdthebuildingup• Resistsoilpressures• Keepthegroundwaterout• Keepthesoilgasout• Keepthewatervaporout• Allowanywatervaporinthewalltoleave• Keeptheheatinduringthewinter• Keeptheheatoutduringthesummer
Basementfailuresoccuroftenduetoflooding,orcondensation,bothofwhichmayresultinmouldordustmiteproblems.However,buildingphysicsandextensivefieldexperiencehasshownthatthemajorityofallbasementmoistureandcomfortissuescanbeavoidedbyproperdesignandmaterialselection.
Thisstudycomparesoveradozenbasementandfoundationenclosuredesignsincludinghistoricalconstructionstrategies,codeminimumconstructionandhighlyinsulatedconstruction.Thisreportdemonstratesthroughcomputerbasedsimulationsandfieldexperience,differencesinenergyconsumption,thermalcontrol,andmoisturerelatedissues.
ThisstudyisanextensionofthepreviousBuildingAmericastudyofHighRwallassemblies(StraubeandSmegal2009),tocontinuetoimprovetheoverallbuildingenclosureandachievegreaterenergysavings.
1. OBJECTIVE
Thegoalofthisresearchistofinddurable,costeffectivebasementinsulationsystemthatcanbeincludedwithotherenclosuredetailstohelpreducewholehouseenergyuseby70%.Thisreportwillcompareavarietyofbasementandfoundationinsulatingstrategiesandpresenttheiradvantagesanddisadvantagesaccordingtoseveralcomparisoncriteria.
Building Science Corporation 5 www.buildingscience.com 30 Forest St. Somerville, MA 02143
2. SCOPE
Thisstudyislimitedtobasementandfoundationsystemsforcoldclimates.Apreviousstudywasconductedforwallsystemsandfurtherstudiesshouldbeconductedtoaddressroofsandattics.Ingeneral,onlycoldclimatesareconsideredinthisreportsinceenclosuresincoldclimatesbenefitthegreatestfromahighlyinsulatedbuildingenclosure,butimportantconclusionscanalsobedrawnforotherclimatezones.
3. APPROACH
Thequantitativeanalysisforeachwallsystemisbasedonathree‐dimensionalenergymodelingprogramandaone‐dimensionaldynamicheatandmoisture(hygrothermal)model.Minneapolis,MNinIECCclimateZone6wasusedastherepresentativecoldclimateformostofthemodeling,becauseofcoldwinterweatherandfairlywarmandhumidsummermonths.
B.Analysis 1. WALL ASSEMBLIES REVIEWED
Becausethereareanumberofvariablesforeachpossiblewallsystemdependingonthelocalpractices,climate,andarchitectorgeneralcontractorpreferences,anattemptwasmadetochoosethemostcommonwallsystemsandmakenotesaboutotheralternativesduringanalysis.Thislistofchosensystemsisexplainedinmoredetailintheanalysissectionforeachwallsystem.
• Case1:Un‐insulatedBasement• Case2:CodeminimumR10continuousinsulationwithpoly• Case3:3.5inchesfiberglassbattin2x4SPFwoodframedwallwithpoly• Case4:1inchXPS+3.5inchesfiberglassbattin2x4SPFwoodframedwall• Case5:2inchesXPS+2inchespolyisocyanuratewithR10underslab• Case6:3.5inches2.0ccpcfsprayfoamwithR10underslab• Case7:6inches0.5ocpcfsprayfoamwithR10underslab• Case8:2inchesXPS+3.5inchesfiberglassbattin2x4SPFwoodframedwallwithR10underslab• Case9:2inchespolyisocyanurate+3.5inchescellulosein2x4SPFwoodframedwallwithR10under
slab• Case10:6inches0.5ocpcfsprayfoaminoffset2”x4”SPFwoodframedcavitywithR10underslab• Case11:4inchesXPSonexteriorofbasementwithR10underslab• Case12:4inchesXPSincentreoffoundationwallwithR10underslab• Case13:ICFwallwith4”XPSandR10underslab• Case14:2inchesXPS+5.5inchesfiberglassbattin2”x6”SPFwoodframedwallwithR10underslab
2. ANALYSIS CRITERIA
Acomparisonmatrixwillbeusedtoquantitativelycompareallofthedifferentbasementinsulationstrategies.Avaluebetween1(poorperformance)and5(excellentperformance)willbeassigned,uponreviewoftheanalysis,toeachofthecomparisoncriteriaforeachwall.AnemptycomparisonmatrixisshownbelowinTable1asanexample.
Building Science Corporation 6 www.buildingscience.com 30 Forest St. Somerville, MA 02143
Table 1: Criteria comparison matrix
Thecriteriascoreswillbesummedforeachinsulationstrategy,andthewallswiththehighestscoresarethepreferredoptionsassumingallofthecomparisoncriteriaareweightedequally.Itisalsopossibletoweightthedifferentcomparisoncriteriaasymmetricallydependingonthecircumstancessurroundingaparticularwalldesign.Theweightingsforeachwallwillfallbetween1(leastimportant)and5(mostimportant).Theweightingismultipliedbythecomparisoncriteriascoreandaddedtootherweightedvalues.Anexampleoftheweightedconclusionmatrixwillbeshownintheconclusionssectionofthisreport.
Oneofthebenefitsofusingacomparisonmatrixisthatitallowsaquantitativecomparisonwhensomeofthecriteria,suchascostmaybepoorlydefinedorhighlyvariable.Forexample,eventhoughtheexactcostsofdifferentinsulationsmaybeuncertain,fiberglassbattinsulationisalwayslessexpensivethanlowdensity(0.5pcf)sprayfoamwhichislessexpensivethanhighdensity(2.0pcf)sprayfoam,sothesesystemscanberankedaccordinglyregardlessoftheactualcosts.
Eachofthecriteriaaredescribedindetailbelow.
Building Science Corporation 7 www.buildingscience.com 30 Forest St. Somerville, MA 02143
2.1 Thermal Control and Heat Flow Analysis
TheHeatflowandenergyanalysisofeachbasementsystemwasconductedwithBasecalc,developedbyCanmetENERGYandbasedontheNationalResearchCouncilofCanada’sMitalasmethod.Mitalasusedmainframecomputerstoperformfinite‐elementanalysesofalargenumberofbasementsandanalyzedtheresultstoproduceaseriesofbasementheat‐lossfactors,whichwerethenpublishedasareference(Mitalas1983).
AusercanapplytheMitalasmethodbyusingthecorrectheat‐lossfactorsfromthepublishedtablesandperformaseriesofcalculationstopredictheatandenergylosses.Basecalcincorporatesthefinite‐elementapproachMitalasusedtogeneratetheheat‐lossfactors.DuringthisstudyananalysisspreadsheetmodelwasconstructedusingtheMitalasmethodandcomparisonsoftheresultsbetweentheanalysisspreadsheetandBasecalchavebeenconducted.
TheBasecalcsoftwareisarelativelysimplemenudrivenprogramthathasmanyoptionsforconstructionstrategies,insulationplacementandsiteconditions(Figure1).
Figure 1 : Screen Capture showing inputs for Basecalc
SomeassumptionsweremadeforalloftheBasecalcanalysistoensurecomparisonwaspossiblebetweenresultingsimulations.Theenergycalculatedisonlyforthesespecificcases,andmodifyinganyofthevariablesmaychangetheresultingenergyrequirements.Theseassumptionsarelistedbelow:
Building Science Corporation 8 www.buildingscience.com 30 Forest St. Somerville, MA 02143
• AllsimulationswererunforMinneapolis/St.PaulMN,dataincludedinBasecalc• Basementinteriorheight‐distancefromtopofslabtotopoffoundationwall2.44m(8ft)• Depth(belowgradefoundation)–distancefromtopofslabtosurfaceofground,2.13m(7ft)• Width‐exteriorofstructuralwalltoexteriorofstructuralwall,10m(32.8ft)• Length–exteriorofstructuralwalltoexteriorofstructuralwall,15m(49.2ft)• Basementwallarea–118m2(1270ft2)• Basementfloorslabarea–140m2(1506ft2)• Basementperimeter–48.5m2(159ft2)
InBasecalc,therimjoistisnotconsidered,(butthiswasanalyzedinpastresearch,StraubeandSmegal2009),butthermalbridgingacrossthetopofthefoundationwallisconsidereddependingonabovegradewallconstruction.Forexample,oneofthemostcommonthermalbridgesintypicalresidentialconstructionistheexteriorabovegradebrickcladdingsittingontheoutsideedgeofthefoundationwall.
Figure 2 : Typical construction thermal bridging through foundation and brick cladding ThisthermalbridgingcanbetakenintoaccountinBasecalc.Forallsimulationsinthisstudy,theabovegradecladdingwasassumedtobenon‐brickveneer.Intypicalconstructionwithbrickveneer,thereisasignificantthermalbridgebetweentheinteriorandexteriorwhenthebrickcladdingisinstalledontheexterioredgeoftheconcretefoundationwall.Itwasassumedthattherewasnosignificantthermalbridgeatthetopofthefoundationwall.
AlloftheBasecalcresultsarepresentedinunitsofMBtus.Forclarification1MBtuanditsequivalentenergyinothercommonunitsofmeasureareshowninTable2.
Table 2 : Conversion of 1 MBtu to Other Common Energy Units MillionBtu’s(MBtu’s) 1
Btu’s 1,000,000
Therms 10
Megajoules 1,057
Kilowatthours 293.6
Building Science Corporation 9 www.buildingscience.com 30 Forest St. Somerville, MA 02143
Acommonwaytoexplainenergysavingstohomeownersisoftenindollarssavedsincethevalueofadollariswellknownandcanbecomparedtootherdesigndecisions.Unfortunately,pricesvaryconsiderablyacrossthecontinentforheatingenergy,andalsovarydependingonthetechnologyusedforheating,whetheritbeelectricity,naturalgas,oil,etc.Foranalysispurposes,ifcostcomparisonsareuseditwillalwaysbeforelectricheatingat15centsperkilowatthour($44/MBtu).Asacomparison,naturalgasat$1.50/thermburntina90%efficientfurnacecosts$16.70/MBtu.Thecostofenergyislikelytorise,eventhoughtherateofincreaseisunknown,sodollarsavingsarelikelytobehigherinthefuture.
2.1.1. Building Code Requirements Accordingtothe2009IECCinclimatezones4orhigher,thebuildingcoderequiresaminimumofR10continuousinsulation(e.g.fiberglassrollbatt)orR13discontinuous(e.g.framedwallwithR13fiberglassbatt)unlessitisanunconditionedbasementandtheflooroverheadisinsulatedinaccordancewithIRCSectionsN1102.1andN1102.2.6.AddingthisrequiredamountofinsulationmakesasignificantdifferencefromanenergyperspectiveasshowninFigure3,butmaynotadequatelyaddressthecomfort,moistureandhealthconcernsthatoccurinbasements.Case1inthisstudyisanun‐insulatedbasementasmanysuchcasescanbefoundinexistingbuildings,andCases2and3aretypicalofcodeminimumbasementsbuiltinmanycoldclimates.
Aninitialanalysiswasconductedtodeterminetheeffectsofdifferentamountsofinsulationandstrategiesonthetotalheatlosspriortoanalyzingthevariouswallsystems.Figure3showstheimprovementsinannualenergylossbyinsulatingthefullheightofthebasementwallwithdifferentinsulationvaluescomparedtoanun‐insulatedbasement.ThemostsignificantimprovementisachievedbyaddingthefirstR5,whichshowsthataddinganyinsulationcouldhelpwithenergylosses.IncreasingtheinsulationtoR10whichisthecodeminimumasacontinuousinsulationresultsinapredictedenergysavingsof31.2MBtus(savingsof$1372/yearbasedon$0.15/kWhror$44/).Theenergysavingsshouldbeconsideredwhendeterminingthecostofaddinginsulation,andwhetherornotitiscosteffective.
Thebasementwallhasanareaofapproximately1270ft2andR5foaminsulationcostsapproximately50‐75¢/sfplusinstallation.UsingR10rigidfoaminsulationovertheentirebasementinthiscasewouldcostintherangeof$1270to$1905,andwouldsaveapredicted$1372/year.
Figure3alsoshowsthepredictedenergysavingsiftheslabisinsulatedwithR10belowtheslab.Intheun‐insulatedcasethereisanimprovementofHeatingSeasonEnergyLossof1.3MBtus,andintheR20insulatedwallcomparisontheimprovementisslightlyimprovedwithunderslabinsulationat1.5MBtus.However,themostimportantaspectsoftheunderslabinsulationarenotshownonthisgraph.Comfortlevelsandmoisturerelatedissuesincludingdampnessandmustyodors,andstorageofmoisturesensitivematerialsonthefloorwilldecreaseifunderslabinsulationisused.Insomecaseswhenradiantfloorheatingisused,R20orgreaterunderslabinsulationisnecessarytoreducetheheatlosstotheground.
Building Science Corporation www.buildingscience.com
30 Forest St. Somerville, MA 02143
Figure 3 : Reduction in Energy Loss with the Addition of Full Height Foundation Wall Insulation
Building Science Corporation www.buildingscience.com
30 Forest St. Somerville, MA 02143
Figure 4 : Comparison of Different Underslab Insulation Techniques with R10 on foundation walls
Building Science Corporation www.buildingscience.com
30 Forest St. Somerville, MA 02143
Figure 5 : Energy Savings From Thermal Break Insulation Between Concrete Footing and Slab
2.1.2. Case Study – Westford Prototype House
Building Science Corporation 13 www.buildingscience.com 30 Forest St. Somerville, MA 02143
Figure 6 : Basement Floorplan of BA Westford Prototype House H2KwasalsousedtosimulatetheheatingenergylossesoftheWestfordprototypehouseanditwaspredictedthat6.96MBtusarelostbelowgrade,and2.36MBtusarelostabovegradeinthebasementforatotalbasementheatlossof9.32MBtusinayear.H2Kalsopredictedthetotalhouseheatingenergylossesof27.16MBtus,verysimilartotheEnergyGaugevalue.
Inthisstudy,Basecalcwasusedtodeterminethetotalannualenergylossthroughthebasementis7.1MBtuswhichissimilartotheH2Kvalue.BymodifyingsomeoftheinsulationvaluesinthebasementusingBasecalc,theeffectonthetotalhouseenergycanbeseentodetermineifincreasesininsulationvaluesarecosteffective.
Table3showstheeffectonthepredictedwholehouseheatingenergylossesbychangingtheamountofinsulationundertheslab.
Table 3 : Effects of Whole House energy by changing Underslab Insulation
Building Science Corporation 14 www.buildingscience.com 30 Forest St. Somerville, MA 02143
PredictedBasementEnergyLosses[MBtu]
ChangeinBasementEnergyLosses[MBtu]
ChangeinWholeHouseEnergyLosses[%]
RemovingUnderslabinsulation 8.4 1.3 4.8%
R10underslab 7.1 0 0
R20underslab 6.2 ‐0.9 ‐3.4%
R30underslab 5.7 ‐1.4 ‐5.0%
Table3showsthat1.3MBtusweresavedbyaddingR10underslabinsulation,asavingsofalmost5%oftheentirehouse’sheatingenergylosses.Astheunderslabinsulationisincreased,thechangestotheentirehouse’sheatingenergylosesbecomemuchlesssignificant.Tosaveanotherapproximately5%oftheentirehouse’sheatingenergylosses,anotherR20isrequiredabovetheoriginalR10insulation.
Table4showstheeffectonthepredictedwholehouseheatingenergylossesbychangingtheamountofinsulationonthefoundationwalls.
Table 4 : Effects of Whole House Energy by Changing Foundation Wall Insulation
PredictedBasementEnergyLoses[MBtu]
ChangeinBasementEnergyLosses[MBtu]
ChangeinWholeHouseEnergyLosses[%]
R10codeminimumfoundationwallinsulation 10.4 3.3 11.9%
R26foundationwallinsulation 7.1 0 0
R40foundationwallinsulation 6.2 ‐0.9 ‐3.4%
Table4showsthat12%oftheheatinglossesofthehousearesavedfromincreasingthefoundationwallinsulationfromthecodeminimumR10toR26,whichisasignificantportionoftheheatingenergylosses.Thisshowsthatitcanbecosteffectivetoinsulatethebasementincoldclimatesbasedonheatingenergyalone,withoutconsideringallofthemoisturerelatedbenefits.
ByincreasingtheinsulationanotherR13toR40,resultsinonlya3.4%decreaseintheheatingenergylossesfortheentirehouse.At$1.20/sf,thisinsulationwouldcost$1062,andwouldsave0.9MBtu/year.
2.1.3. Basement Wall Analysis ThefourteendifferentwallslistedpreviouslyweresimulatedinBasecalc,andtheheatingenergylosseswereestimated.SomeoftheproposedwallsystemshadcontinuousinsulationandtheR‐valueswereassumedtobeequaltotheirrating.Otherproposedwallsystemswereframedorfurredouttotheinteriorandinsulatedwithcavityinsulation.Theframingmaterialsintheseassembliesactasathermalbridgebypassingtheinsulation.Fortheframedwalls,theparallelpathmethodwasusedtocalculatetheR‐value,whichisaratiooftheRvaluethroughtheframingtotheR‐valuethroughthecenterofthestudspace,assumingaframing
Building Science Corporation 15 www.buildingscience.com 30 Forest St. Somerville, MA 02143
spacingof24”oncenter.Alsotakingintoaccountthegypsumwallboardandsurfacefilm,thethermalbridgingoftheframingdidnotsignificantlyaffecttheR‐value,infact,insomecasesthecalculatedparallelpathR‐valuewasslightlyhigherthantheinstalledinsulationR‐value.
Underslabinsulationandaslab‐edgethermalbreakwereonlyincludedinsimulationsforCases5to14,sinceitisunlikelythatbuilderswillinstallunderslabinsulationwhenonlyminimalfoundationwallinsulationispresent.
Figure 7 : Comparison of Heating Energy Losses for all Cases Asstatedpreviously,evenR10foundationwallinsulationshowedasignificantamountofenergysavingscomparedtoun‐insulatedbasements.However,insomecases,increasingtheinsulationincreasestheriskformoisturerelatedproblemsthatwillbeanalyzedintheHygrothermalAnalysissection.
Therangeofenergylossfortherecommendedfoundationinsulationstrategies(Cases5–14)is14.8to19.43MBtusperyearforthespecifichouseexamined.Cases5‐10,13,and14haveessentiallyidenticalperformance.Thevalueofthesesavingsdependsonthecharacteristicsofthehouse,theclimatezone,thetypeofenergyusedanditsassociatedcost.
ThebestperformingfoundationinsulationstrategiesfromaheatlossperspectiveareCase14(2”XPS,5.5”fibreglassbatt)andCase9(2”PIC,3.5”cellulose),butthereareseveralothersthatperformverywell.TheadvantagesanddisadvantagesofthevariousinsulationstrategieswillbecomparedfurtherintheAnalysissection.
Building Science Corporation 16 www.buildingscience.com 30 Forest St. Somerville, MA 02143
2.2 Hygrothermal Analysis
Moisture Balance
Assessingmoisturerelateddurabilityrisksinvolvesthreedifferentmoistureprocesses;wetting,dryingandmoistureredistribution.Thesethreeprocessesincombinationwiththesafestoragecapacityofeachcomponentwilldeterminetheriskofmoisturedamagetoabasementassembly.Thisreportonlyincludesabriefoverviewofthewettingmechanisms(moredetailbyJosephLstiburek2006).
Therearefourmainwettingmechanismsinfoundationsandbasements.Theyare:
Bulkwaterpenetrationfromtheexterior Capillarywickingor“risingdamp” Vapordiffusionandairleakagecondensation(fromexteriororinterior) Plumbingissuesontheinterior(notconsideredinthisanalysis)
Thegreatestamountofdamageintheshortesttimewillbecausedbyabulkwaterpenetrationfromtheexteriororinteriorplumbingrelatedissues.Thebeststrategytoavoidwateringressintothebasementfromtheexterioristodrainallofthecomponentsawayfromthebuildingincludingthesiteandtheexteriorofthefoundation(Figure7).Sometimesitisunavoidabletohaveliquidwaterincontactwiththefoundationandotherstrategiesmustbeusedincludingexteriordrainagematsandsumppumps.Inolderbuildings,foundationwallsmayhavebeenconstructedofrubbleorstoneandoftenallowwaterdirectlythroughthefoundationwallintherainyorthawseason.Ensuringbasementdrainsareproperlylocatedandthattheyareclearofobstructionswillminimizefloodingcausedbyinteriorplumbingissues.Thisstudydoesnotdealspecificallywithretrofitstrategies,butthepossibilityofuseinretrofitapplicationswillbementionedforanyrelevantinsulationstrategies.AdditionalinformationregardingtheretrofitofbasementsisavailableinPettit(2005).
Building Science Corporation 17 www.buildingscience.com 30 Forest St. Somerville, MA 02143
Figure 8 : Drainage details to minimize foundation moisture issues Thesecondsourceofmoistureinthebasementenclosureismoisturetransportedfromwetsoilbycapillarywicking.Thephysicalcharacteristicsandporesizeofconcrete(10–1000nm)allowittowickmoisturequiteeffectivelyagainsttheforceofgravity,oftenwithsuctionpressuresof100kPato10MPa(StraubeandBurnett2005).Themostcommonsourceofwaterforcapillaritywickingisthefooting.Inmanycasesamoisturebarriersuchasdamp‐proofing,oradrainagemembrane,orbothareappliedtotheexteriorofthewallminimizingtheriskofcapillaryabsorptionthroughthefoundationwall.Thefloorslabisoftenpouredovergravelwhich,ifithasnofines,actsasacapillarybreakandshouldbedrainedtotheexteriordrainagetile.Inmanyhousefoundations,thereisnocapillarybreakinstalledontopofthefooting,andthereforewaterdrawnintothefootingisalsowickedfurtherupthefoundationwall.Inatypicalbasement,theliquidwaterisdrawntothesurfacesoftheconcretefoundationwall(Figure9),itwillevaporateanddrytotheinteriorortotheexteriorasenvironmentalconditionspermit.Ifdryingishinderedbyapolyethylenevaporbarrier,elevatedrelativehumiditiesmayoccurnearthewallsurfaceorwithinthewallcavityeventuallyresultinginmouldandothermoisturerelatedissues.
Ashomeownersfinishandinsulatetheirbasementspaces,apolyethylenevaporbarrierisofteninstalledtomeetthelocalbuildingcode.Somebuilderswhohavelearnedfrompastexperiencewillremoveasectionofthepolyethylenevaporbarrieratthebottomtoavoidmoldproblemsthathavebeendiscoveredinmanybasements.Removingthebottomsectionofthevaporbarrierallowsliquidwaterwickedupthefootingandintothefoundationwalltodrytotheinteriorspace.Thepreferredsolution,ofcourse,wouldbetoinstallacapillarybreakbetweenthefootingandfoundationwallduringtheoriginalconstructionprocesstostop
Building Science Corporation 18 www.buildingscience.com 30 Forest St. Somerville, MA 02143
moisturefrombeingwickedintothefoundationwall.Alternatively,amoisturetolerantinteriorfoamlayercanreducetheflowtotheinteriorsufficientlytoavoiddamage(ifnoadditionalvaporbarrierisadded).
Figure 9 : Capillary rise through basement footing Thethirdsourceofmoistureinthebasementenclosureiscausedbyvapordiffusion.Asdiscussedwithcapillarityabove,vapordiffusionoccursfromtheinteriorsurfaceoftheconcreteafterwateriswickedupthefoundationwall.Vapordiffusioncanalsooccurthroughfloorslabifnovaporbarrierisinstalledbelowtheslab.Therateofvapordiffusionisslow,butstillmaycausedurabilityissueswithvaporimpermeableflooringsinstalledwithwaterbasedadhesives,aswellasincreasingthemoistureloadinthebasement,whichcancontributetothecommondamp,mustyodour.Vapordiffusionthroughtheslabcanbevirtuallyeliminatedbyinstallingavaporcontrollayer(6milpolyethylene,boardfoaminsulationorsprayfoam)undertheslab.Interiormoisturevaporcouldalsobeanissue,especiallyinlatespringandearlysummerastheenvironmentalrelativehumidityincreasesbuttheconcretefoundationtemperaturesarestillcoolerbecauseoftheseasonaltemperaturelagoftheearthandthermalmass.
Vapordiffusiondryingoftheconcretecanlastforseveralyearsuntiltheconcretefullyhydrates,evenifothersourcesofmoistureareeliminated.Ifthereisnomoisturebarrierontheexterioroftheconcrete,thentheconcretewillneverdrycompletelyandwatervaporwillalwaysbepassingintoandthroughtheconcrete.
Dryingisimportantsincenearlyallbuildingenclosureswillexperiencewettingatsomepoint.Inabove‐gradefoundationwalls,thereisdryingpotentialtoboththeinteriorandexterioriftheenclosuredesignallows.Belowgrade,however,dryingcanonlyoccurtotheinteriorsincetheexteriorsurfaceofabelowgradewallisatessentiallyat100%humidityallyearround.
Thesafestoragecapacity(balanceofwettinganddrying)ofanindividualmaterialorenclosuresystemisfundamentaltogoodbuildingdesign(Figure9).Itisrarelyeconomicaltobuildanenclosurewithnoriskofwettingbutmanagingtheriskisimportant.Inanybuildingenclosure,buildingmaterialsshouldbechosen
Building Science Corporation 19 www.buildingscience.com 30 Forest St. Somerville, MA 02143
basedonmoisturetolerancethatcorrelatetotheriskofmoistureintheenclosure.Inallcasesdryingshouldbemaximized,andattentiontogooddesigndetailsshouldbeused.
Figure 10 : Moisture balance
Manyhouseshavedamp,mustysmellingbasementsthatareuncomfortable,andcanbeunhealthy.Historically,peopledidnotfinishtheirbasementsintolivingspacessoitwasnotasmuchofaconcern,butnowbasementsarebeingconvertedtolivingareas,entertainmentcentresandbedrooms,sohealthandcomfortareasmuchaconcernasforabove‐gradespace.
Afoundationshouldcontroltheamountofliquidwaterandwatervaporenteringtheinteriorspacefromtheexteriorenvironment.Thisstudyassumesdrainagedetailshavebeenconstructedcorrectlytolimittheexposureoftheexteriorofthefoundationtoliquidwater.Therearemanydifferentstrategiestoensurewaterisdrainedawayfromthefoundation,butallsystemsrequireproperlydetaileddrainagealongthefoundationfootingtoremovestandingwater.Thefoundationwallneedstohaveadrainageplanethatdirectsbulkwatertothisfootingdrain.Often,adrainagemembraneisinstalledagainsttheexteriorofthefoundationwalltoperformasbothliquidwaterandwatervaporbarrier.Thedrainagemembraneisrippledorcorrugatedandformsaspacebetweenthemembraneanddampproofedconcretefoundationwall,allowinganywateragainstthefoundationtodraintothedrainagetile.Thisensuresthatthefoundationdoesnotexperienceanyliquidpressurehead.
Eveninaridclimates,thegroundisverycloseto100%relativehumidity,sothatthebelowandabovegradeportionsofafoundationwallexperiencedifferentmoistureandtemperatureregimes.Atthebottomofthebasementwall,thevapordriveistotheinteriorfortheentireyear,andthetemperatureisrelativelystable.Theabovegradeportionofthefoundationwallisverydifferentfrombelowgrade:thevapordriveiscycleddailythroughenvironmentalvariationsofprecipitation,windandsun.
Thehygrothermalsimulationsinthisstudydonotconsiderliquidwateruptakebycapillarityintothefootingandfoundationwall,onlyvapordiffusion.Itisimportanttorecognizethatwaterisoftenwickedupthroughthefootingintotheconcretewall.Oncetheliquidwaterreachestheinteriororexteriorofthebasementwall,itmustbeevaporatedtowatervaporandtravelsbyvapordiffusion.Sincetheexteriorofthefoundationisalreadycloseto100%relativehumidity,themoisturecannotdrytotheexterioranditcanonlyevaporatetotheinside,whichaddstothemoistureloadattheinsulationlayer.Waterthatiswickedthroughthefootingcanbestoppedbyapplyingacapillarybreakbetweenthefootingandthefoundationwall.Therearebothliquidandsheetappliedcapillarybreaksthatwilldecreasethemoistureloadintothefoundationwallandintotheinteriorenvironment.
Building Science Corporation 20 www.buildingscience.com 30 Forest St. Somerville, MA 02143
Sincethefoundationwallbelowgradeisunabletodrytotheexteriorandtherecanbeasignificantamountofmoisturepresentintheconcrete,intuitively,thevapordrivesshouldbeallowedtodrytotheinteriorandapolyethylenevaporbarriershouldnotbebuiltintotheinteriorofthewoodframedwall.Unfortunately,buildingcodeshaveoftenspecifiedpolyethylenevaporbarriersontheinteriorofframedwallsinfinishedbasementsandthesewallswillbeanalyzedtounderstandwhytheyoftenhaveseriousmoisturerelatedproblems.
Thehygrothermalsimulationsconductedforthisstudyareaonedimensionalapproximationofthehygrothermalbehaviourofeachwallsystem.Inrealitytherearetwoandthreedimensionalinteractionssuchasheattransferupanddowntheconcretefoundationwallaswellasconvectiveloopingandmoisturetransportthroughairandvaporpermeableinsulations.
BoundaryConditions
TheWUFIsimulationswereconductedinthreepartsbecauseofthedifferenthygrothermalregimesatthetopabovegradeportion,middleandbottombelowgradeportionsofthewall.TheexteriorbelowgradetemperaturesusedforhygrothermalsimulationswerebasedonmonitoringofgroundtemperaturesinSt.PaulMNasshowninFigure11.TheabovegradetemperaturesforMinneapolisareincludedintheweatherdataforWUFI.
Building Science Corporation 21 www.buildingscience.com 30 Forest St. Somerville, MA 02143
Figure 11 : Monthly temperature variation with soil depth, St.Paul, MN (Bligh 1975) Therelativehumidityoftheexteriorforboththemidheightandbottomofthefoundationwallweresetat99.9%.Inthesesimulations,onlyvapordiffusionfromboththeinteriorandexteriorweresimulatedanditwasassumedthatthefoundationwallandslabwerenotincontactwithliquidwater.Iftheconcreteisincontactwithliquidwater,whichisnotuncommon,especiallyatthefooting,capillarywickingwilloccurandsignificantlyincreasethemoistureloadtothesurfaceoftheconcretenotonlyatthebaseofthewallbutfurtherupaswell.Thiswouldsignificantlyincreasethemoistureloadsabovethepredictedvalueswherethereisnotcapillarybreakinstalledinthefoundationenclosuresystem.
Interiortemperatureandrelativehumiditieswerechosentorepresentaslightlyhigherthanaveragemoistureloadforacoldclimatehouse(Figure12).Theseboundaryconditionsweresimulatedfor10yearstoensurethatthefoundationsystemwasatequilibriumwithboththeexteriorandinteriorenvironments.
Building Science Corporation 22 www.buildingscience.com 30 Forest St. Somerville, MA 02143
Figure 12 : Interior Temperature and Relative Humidity for Hygrothermal Simulations
2.2.1. Wintertime Condensation
Inabovegradewalls,wintertimeairleakageandvaporcondensationareconcernsincoldclimates.Inthebasement,thebelowgradefoundationwallisoftenwarmerthantheexteriorenvironmentinthewinterduetotheheatsinkoftheground,andthethermallymassivestorage.Thismeansthatwintertimecondensationislessofaconcernonthefoundationwallitself.Intheabovegradeportionofthebasementwall,therecanbecondensationasshowninthefollowinghygrothermalanalysis.
Ofgreaterconcernistheearlysummerwhenthefoundationwalliscoolerthantheexteriorenvironmentandoftentherelativehumidityintheenvironmentcanbequitehigh.Iftherelativehumidityincreasesinthebasement,thiscouldresultincondensationandelevatedhumiditiesatenclosuresurfacessuchasonthewallsandfloor.Inbasementswithacarpet,theconcreteslabisslightlyinsulatedfromtheinteriorwarmthandhigherrelativehumiditiesarepossiblesincethecarpetisvaporpermeable.
2.2.2. Summer Inward Vapor DrivesAtthetopofthefoundationabovegradewallthereispotentialforinwardvapordrivesbecauseitissubjectedtothewarmsummertimetemperaturesandsolardrives.Thiswillonlyoccurwherethewallisheatedsufficientlytodrivethevaporintotheenclosure,andisevidentinsomewallassembliesinthehygrothermalanalysis.
Polyethylenesheetbondedtobattinsulationhastypicallybeentheconstructionstrategyusedforinsulatingcoldclimatebasementsinthepast,butnow,withincreasedunderstandingaboutthemoisturephysicsof
Building Science Corporation 23 www.buildingscience.com 30 Forest St. Somerville, MA 02143
basementsandbelowgradewalls,theIRC(InternationalResidentialCode)statesthatClassIandIIvaporretardersarenotrequiredonanybelowgradewallorbasements(IRC2009TableR601.3.1).
Someinsulationsinstalleddirectlyagainstthefoundationareeffectivevaporcontrollayersandinsulationlayersasshowninthehygrothermalanalysis.
2.2.3. Wall DryingBelowgradewallsexperienceelevatedrelativehumiditesontheexteriorandthusmustdrytotheinterioratalltimes.Theabovegradeportionofthefoundationwallcandrytoeithertheinteriororexteriordependingonwallconstruction,butitisrecommendedthattheentirebasementwallbeabletodrytotheinterior.Insomecases,lowerpermeancecoatingsmayberequiredbutaClassIorIIvaporcontrollayershouldbeavoided.
2.2.4. Case 1 Un-insulated Figure13showsthemoisturebehaviorofanun‐insulatedbasementwall.Predictedrelativehumiditiesatthesurfaceoftheconcretewallshowthereisverylittlepotentialforcondensation,onlyatthecoldesttimeofyearonthenorthorientationwithnosolarenergydoestheinterioroftheconcretegetcoldenoughtocondensewatervaporfromtheinteriorenvironmentwiththesimulatedinteriorrelativehumiditylevels.
Figure 13 : Predicted RH at the Interior Surface of the Concrete Foundation Wall for Case 1 ThepredictedsurfacetemperaturesofthefoundationwallandthedewpointoftheinteriorairareshowninFigure14.ThisshowsonlyacoupleshortinstancesofpredictedcondensationinearlyJanuary,andonlyontheabovegradeportionofthenorthwall.
Building Science Corporation 24 www.buildingscience.com 30 Forest St. Somerville, MA 02143
Thisanalysisfortheun‐insulatedbasementassumesthattheinteriorrelativehumidityiscontrolledto31%inthewinterand58%inthesummer(Figure12).ThiswouldlikelyrequireadehumidifiersincetherearenovaporcontrollayersonthefoundationwallorbasementslabandthemoistureloadfromthesesurfaceswouldkeeptheRHinthebasementspacehigh.Iftherelativehumidityiscontrolledtothetheserelativehumiditiesasaminimumcontrol,thenthisbasementwillperformreasonablyfromamoistureperspective,withlittleriskofmould.Fromathermalcontrolperspective,however,thiswallisaverypoorperformer.
Figure 14 : Condensation Potential for Interior air on the Surface of the Concrete Foundation Wall
2.2.5. Case 3 - Code compliant basement Cases2and3weresimilarenoughthatseparatesimulationsforbothconditionswerenotrequired.Thesesimulationswereconductedwithapolyethylenevaporbarrierbecausetherearemanybasementsinexistencebuiltwithapolyethylenevaporbarrierontheinteriorsurfaceofthewall.TheIRCstatesinR601.3.1,thataClassIorIIvaporretarderisnotrequiredonbasementwallsorthebelowgradeportionofanywall.InothergeographicareassuchaspartsofCanada,thebuildingcodewithrespecttobasementshasnotbeenmodifiedtoreflectthelargenumberofbuildingfailures,andthemoisturephysicsofbasements.
Manycompanieshaveaninsulationproductsimilartoatraditionalrollbattwithpoly,butwithaperforatedfacerthatallowsvaportopassbothwaysthroughtheinteriorsurface,dependingonthetimeofyearandinteriorconditions.Simulationswerenotconductedyettoaddressaperforatedfacer,butintuitively,vapordiffusionwillbehigherbothways,andairleakagecondensationwillbesignificantlygreateracrossaperforatedfacerthananonperforatedfacer.Thisisnotarecommendedinsulationstrategy.
Figure15showstherelativehumidityatthesurfaceofthefoundationwallforwallCase3.Notsurprisinglyitisquitehigh.Theconcreteisgenerallywet,bothfromcapillarywickingandbyvapordiffusionfromtheexterior.Therelativehumiditydoesdecreaseatthetopofthefoundationwallinthesummermonths,when
Building Science Corporation 25 www.buildingscience.com 30 Forest St. Somerville, MA 02143
theconcreteiswarmedbyexteriortemperatures.Aperforatedfacermaydecreasetherelativehumidityslightly,dependingonthevaporpermeance.
Figure 15 : Predicted Relative Humidity at the Surface of the Concrete Foundation Wall for Case 3 Inthecaseofawelldetailedpolyethylenevaporbarrier,ittrapssignificantmoistureinthewallasthewetconcretedriestotheinterior,butdoesnotallowairleakagecondensation.Figure16showsthepotentialairleakagecondensationwhenthetemperatureofthefoundationwallfallsbelowthedewpointoftheinteriorair.ThereissignificantcondensationpotentialbetweenOctoberandJanuaryforthetophalfofthefoundationwall,andfromJunetoOctoberatthebottomofthefoundationwall.Thereiscondensationpotentialformostoftheyearontheconcretefoundationwallwiththeassumedconditions.Aperforatedfacerwouldallowairleakagecondensationtooccurresultinginsignificantcondensation.
Thismeansthatthewoodframingneartheconcreteissustainedatorabove90%relativehumidityallyear,whichwilleventuallycausemouldsinceitislikelythattherewillbeliquidwatercondensationinthewallsystemunderthesesustainedconditions.
Building Science Corporation 26 www.buildingscience.com 30 Forest St. Somerville, MA 02143
Figure 16 : Interior Air Leakage Condensation Potential for Case 3 Code Minimum Wall Predictionswerealsomadefortherelativehumidityattheexteriorsurfaceofthepolyethylenevaporbarriersinceitiscommoninabasementtoseecondensationontheexteriorsurfaceofthepoly.Figure17showsthatbetweenJuneandAugust,therelativehumiditynearthetopofthewallisapproximately100%(higheronthesouththannorth)resultingfrominwardvapordrives.Aperforatedfacercoulddecreasethispotentialforincreasedrelativehumidityatthepoly.
Asmentionedpreviously,thesesimulationsdonotincludecapillarywickingforthisanalysis.Inthefuture,thismaybeincluded,sincethecapillarywickingisasignificantsourceofmoistureintheconcreteandbasementwallsystem.
Building Science Corporation 27 www.buildingscience.com 30 Forest St. Somerville, MA 02143
Figure 17 : Predicted Relative Humidity at the Surface of the Polyethylene Vapor Barrier for Case 3
2.2.6. Case 4 - 1” XPS and 3.5” Fibreglass Batt Case3hasseriousmoisturerelatedriskscausedbybothvapordiffusionandairleakagecondensation.Onemethodofminimizingthepotentialrisksistoinstallavaporretardinglayerthatalsoprovidesinsulationagainsttheconcretefoundation.1”ofXPSisonlyslightlyvaporpermeable,andhasanR‐valueofR5.AssumingtheXPSiswellsealedtotheconcretefoundation,thecondensationplaneisnowtheinteriorXPSsurfaceandwillbewarmerthantheconcrete,whichshouldresultinlesspotentialcondensation,andlessvapordiffusionfromtheconcrete.Expandedpolystyrene(EPS)wouldalsoworkasanairbarrierbuthasahighervaporpermeance,sotherewouldbemorevapordiffusionfromtheexterior.SimulationswouldberequiredtoassessthedurabilityofsubstitutingEPSforXPS.
Figure18showsthepredictedrelativehumidityattheinteriorsurfaceoftheXPSinsulationatthebottomandatthetopofthefoundationwallonthenorthorientationwiththreedifferentvaporcontrolstrategies.Usingonlylatexpaintonthedrywall,therelativehumidityreachesapproximately100%atthetopinthewinterandatthebottominthesummer.Byusingavaporretardingpaint(approximately1perm)onthedrywall,therelativehumidityinboththewinterandsummerimproved.
Addingapolyethylenevaporbarrier,therelativehumiditieswereexpectedtoincrease.Atthetopofthewall,therelativehumidityincreasedandwassustainedforapproximatelythreemonths,butthebottomofthewallshowednoincreaseinrelativehumidity.IncreasingtheR‐valuebyusingR‐10foaminsulationreducesthemoisturerisks(SeeCase8).
Building Science Corporation 28 www.buildingscience.com 30 Forest St. Somerville, MA 02143
Figure 18 : Predicted Relative Humidity at the Interior Surface of XPS for Case 4 TheairleakagecondensationpotentialofCase4wasmuchimprovedoverCases2and3asshowninFigure19.Thereisstillairleakagecondensationpotentialsothedrywallmustbemadeasairtightaspossible.
Figure 19 : Interior Air Leakage Condensation Potential for Case 4
Building Science Corporation 29 www.buildingscience.com 30 Forest St. Somerville, MA 02143
Figure20showsthepredictedsurfacerelativehumiditesattheexteriorofthedrywall/polyvaporbarrierdependingonconstructionforCase4.Thetopofthewallexperiencesinwardvapordrives,sothewallwithpolyhasthehighestrelativehumidity.Thevaporbarrierpaintallowsmoredrying,andthelatexpaintedwallhasthelowestrelativehumidity.
Figure 20 : Predicted Relative Humidity at the Exterior Surface of the Gypsum Board for Case 4
2.2.1. Case 5 - 2” XPS, 2” foil face polyisocyanurate(PIC) TherewasnoreasontoconducthygrothermalsimulationsonCase5.Providedthereisnowayforairtobypasstheboardfoaminsulationinstalledagainsttheconcretefoundation,therearenomoisturerelatedrisks.TheInsulationisanairbarrierandvaporretarding,andisnotmoisturesensitive.
2.2.2. Case 6 - 3.5” 2.0 pcf closed cell (cc) spray foam Therewerenoexpectedmoisturerelatedissueswith3.5”ofclosedcellsprayfoamsincetheinsulationiscompletelyairimpermeableandhighlyvaporretarding.Therelativehumiditybetweentheconcreteandsprayfoamismaintainedatapproximately100%butneithermaterialismoisturesensitive.Asimulationwasconductedtoshowtherelativehumidityattheinterfacebetweenthesprayfoamandtheconcretefoundationwall(Figure21).Therearenomoisturerelatedconcernswiththiswallconstructionstrategy.
Closedcellsprayfoamisausefulmethodforretrofittingbasementsthathavemoistureand/orenergyrelatedissues,sinceitcanactasavaporbarrier,airbarrier,andcapillarybreak.
Building Science Corporation 30 www.buildingscience.com 30 Forest St. Somerville, MA 02143
Figure 21 : Predicted Relative Humidity in the Interior Surface of the Foundation Wall of Closed Cell Spray Foam Case 6
Building Science Corporation 31 www.buildingscience.com 30 Forest St. Somerville, MA 02143
Figure 22 : Predicted Relative Humidity at the Interior Surface of Closed Cell Spray Foam Case 6
2.2.3. Case 7 - 6” 0.5 pcf open cell (oc) spray foam SimilartoCase6,opencellsprayfoamcanbesprayeddirectlyagainsttheconcretefoundationwallasaninsulationstrategytoformanexcellentairbarriersystem.However,0.5pcfopencellfoamisvaporpermeable,somoisturerelatedissuescouldoccurunderspecificconditions.Usingsixinchesoffoamwillhelpretardthevapor,andasimulationwasconductedintheinterfaceofthefoamandfoundationwallafterthesystemreachesequilibrium(Figure23).Becauseneitherconcretenorthesprayfoamissusceptibletomoisture,therearenomoisturerelatedrisksforthissystem,providedtheinteriorsurfaceisvaporpermeable.
Building Science Corporation 32 www.buildingscience.com 30 Forest St. Somerville, MA 02143
Figure 23 : Predicted Relative Humidity at the Interior Surface of the Foundation Wall of Open Cell Spray Foam Case 7
Figure 24 : Predicted Relative Humidity at the Interior Surface of Spray Foam of Open Cell Spray Foam Case 7
Building Science Corporation 33 www.buildingscience.com 30 Forest St. Somerville, MA 02143
2.2.4. Case 8 - 2” XPS and 3.5” fibreglass batt Case8isagoodpracticalbasementwallsystem.Figure25showsshortperiodsofelevatedRHattheinteriorsurfaceoftheXPSontheabovegradeportion(inthewinter),andatthebottomofthewall(inthesummer).BoththefiberglassbattinsulationandtheXPSareverymoisturetolerant,andthereislittleriskofcondensationunderthesesimulatedconditions.
Figure 25 : Predicted Relative Humidity at the interior Surface of the XPS for Case 8 Figure26showssomeperiodsduringtheyearwherethereisariskofairleakagecondensationofinteriorbasementaironthesurfaceoftheXPSinsulation.ItisimportanttoensuretheXPSiswelladheredandsealedtothefoundationwallsothereisnoairleakagearoundtheXPS.Theriskofcondensationonlyoccursontheabovegradeportionofthewall,andisworseonthenorthorientationthanthesouthorientationwheretherearesomesolargains.
TherelativehumiditybetweenthedrywallandfiberglassbattinsulationisshowninFigure27,andtherearenorisksofanymoisturerelateddurabilityissues.
Building Science Corporation 34 www.buildingscience.com 30 Forest St. Somerville, MA 02143
Figure 26 : Interior Air Leakage Condensation Potential for Case 8
Figure 27 : Predicted Relative Humidity at the Exterior Surface of Gypsum Board for Case 8
Building Science Corporation 35 www.buildingscience.com 30 Forest St. Somerville, MA 02143
2.2.5. Case 9 - 2” PIC and 3.5” cellulose SimulationswerenotconductedonCase9becauseofthesimilaritytoCase8andCase14.ThePICinCase9hasagreaterinsulationvalueanddecreasedvaportransmission,solessmoisturewillentertheframedwallfromtheconcretefoundationthaninbothCase8andCase14.
2.2.6. Case 10 – 6” 0.5 pcf open cell foam with 2x4 framing offset 2” from foundation NosimulationswereconductedonCase10becauseitwillperformthesamefromamoistureperspectiveascase7asitalsohas6”of0.5pcfopencellfoam.InCase10,theinwardmovingmoisturemayincreasethewoodmoisturecontentoftheframing.Analysisshowedthatatthebottomofthebasementwalltheexterioroftheframingwillreachapredicted85%anddryto55%RH.AtallothermonitoringlocationsthepredictedRHdidnotexceed80%.Thisshouldbeanalyzedfurther,beforebeingconstructed,asitisacomplicatedthreedimensionalhygrothermalprocesswithwoodframingandsprayfoam.Thewoodismorethermallyconductivethanthefoam,sotheexteriorsurfaceofthestudwillbewarmerthanthefoamatthesamedepth.ThiswilllikelydecreasetheRH,butcould,insomecases,increasetheexteriortemperatureoftheframingtomoreidealconditionsformoldgrowth.
2.2.7. Case 11 - 4” XPS on the exterior TherearenomoisturerelatedissueswithCase11ifacapillarybreakisusedatthebottomofthefoundationwall.TheXPSontheexterioractsasavaporcontrollayer,andcapillarybreak,sothefoundationwillstaywarm,anddrier(followingdryingofconstructionmoisture).Thelargestsourceofmoisturewillbecapillarywickingthroughthefootingandbottomoffoundationwallifitisnotaddressed.
2.2.8. Case 12 - 4” XPS in the center of foundation wall Adding4”ofXPStothecenterofthefoundationwallactsasbothacapillarybreakandvaporcontrollayerresultinginlessmoistureontheinteriorandwarmersurfacetemperatures.Thereisnoneedtosimulatethisassemblyandlittlechanceofmoisturerelatedissues.Thelargestsourceofmoisturewillbecapillarywickingthroughthefootingandbottomoffoundationwallifthatisnotaddressed.
2.2.9. Case 13 – ICF, 2” EPS on interior and exterior InsulatedConcreteFormfoundationsareaverydurableandreliableconstructionstrategy.Thetotalof4”ofEPSwillperformasbothacapillarybreakandvaporcontrollayerresultinginlessmoistureontheinteriorandwarmersurfacetemperatures.Theconcreteinthiswallsystemwilltakeaverylongtimetodrycompletelysinceitispouredbetweentwovaporcontrollayers.ThiswillnotaffectmoisturerelateddurabilityissuesprovidedthereisnoClassIorIIvaporretarderinstalledontheinterior.
2.2.10. Case 14 - 2” XPS 5.5” Fibreglass Batt Case14isthesecondhighestR‐valueassemblyinthisstudyataninstalledinsulationR‐valueofR29with2”ofXPSatR10andanR19fibreglassbatt.Thiswallwassimulatedwithbothlatexpaintandvaporbarrierpaint,sincesimulationswithCase4,asimilarwallconstructionshowedthatapolyethylenevaporbarrierincreasedmoisturerelateddurabilityrisks.ThiswallissimilartoCase8,butwithahigherR‐valueofairandvaporpermeablefiberglassbattontheinterioroftheXPS.Thiswallperformssimilarly,butwithslightlyhighermoisturerelatedriskssincethecondensationplanetemperatureiskeptloweratthetopofthewallinthewinter,andatthebottomofthewallinthesummer.
Building Science Corporation 36 www.buildingscience.com 30 Forest St. Somerville, MA 02143
Figure28showsthatthereareelevatedrelativehumiditiesatthesurfaceoftheXPScausedbyvapordiffusionforashortperiodduringthewintermonthsattheabovegradeportionofthewall.Thisriskisdecreasedslightlywithavaporbarrierpaintonthegypsumboard.
Inthesummermonths,therelativehumidityiselevatedatthebottomofthewalliflatexpaintisusedasvaporcontrolbutdecreasedifavaporbarrierpaintisused.
Figure 28 : Predicted Relative Humidity at the interior Surface of the XPS for Case 14 ThereispotentialforsomeairleakagecondensationintheabovegradeportionofthiswallsystemalthoughsignificantlylessthanCase4.Cases8and9withlessairpermeableinsulationtotheinterioroftheXPSwillhaveevenlesspotentialsincethecondensationplanewillbewarmer.Airtightdrywalldetailscanbeusedtominimizethepotentialforairleakagecondensation.
Building Science Corporation 37 www.buildingscience.com 30 Forest St. Somerville, MA 02143
Figure 29 : Interior Air Leakage Condensation Potential for Case 14 Wall
TherelativehumiditywaspredictedattheexteriorsurfaceofthegypsumwallboardinFigure30,whichshowsthereisnomoisturerelatedissuesattheinteriorofthewallsystem.Asshownpreviously,apolyethylenevaporbarrierwouldincreasetherelativehumidityinthesystem,andsignificantlydecreasedryingofthewallsystem.
Building Science Corporation 38 www.buildingscience.com 30 Forest St. Somerville, MA 02143
Figure 30 : Predicted Relative Humidity at the Exterior Surface of Gypsum Board for Case 14
2.2.11. Case 15 - 4” Foil-faced Polyisocyanurate 5.5” Fibreglass Batt Case15isthehighestR‐valueassemblyinthisstudyataninstalledinsulationR‐valueofR45with4”ofpolyisocyanurate(PIC)atR26andanR19fibreglassbatt.ThiswallissimilartoCase14,butwithahigherR‐valueofrigidfoamboardbetweenthefoundationwallandwoodframing.Thiswallperformssimilarly,butwithdecreasedmoisturerelatedriskssincethecondensationplanetemperatureiskeptwarmerbythehigherR‐valuePIC.
Figure31showsthereareelevatedrelativehumidites(~90%)butnoriskofcondensationonthesurfaceofthePICthroughouttheyearatanyheightonthewall.
Building Science Corporation 39 www.buildingscience.com 30 Forest St. Somerville, MA 02143
Figure 31 : Predicted Relative Humidity at the interior Surface of the PIC for Case 15 Thereispracticallynopotentialforairleakagecondensationintheabovegradeportionofthiswallsystem(Figure32),andsignificantlylessthanCases8and14.Airtightdrywalldetailscanbeusedtominimizethepotentialforairleakagecondensation.
Building Science Corporation 40 www.buildingscience.com 30 Forest St. Somerville, MA 02143
Figure 32 : Interior Air Leakage Condensation Potential for Case 15 TherelativehumiditywaspredictedattheexteriorsurfaceofthegypsumwallboardinFigure33,whichshowsthereisnomoisturerelatedissuesattheinteriorofthewallsystem.Asshownpreviously,apolyethylenevaporbarrierwouldincreasetherelativehumidityinthesystem,andsignificantlydecreasedryingofthewallsystem.
Building Science Corporation 41 www.buildingscience.com 30 Forest St. Somerville, MA 02143
Figure 33 : Predicted Relative Humidity at the Exterior Surface of Gypsum Board for Case 15
2.3 Enclosure Durability
Durabilityofthebuildingenclosuresystemwasalsousedtoclassifythedifferentwallconstructionscenarios.Durabilityisusedinthisreporttogrouptogethermultipledurabilityrelatedcriteriasuchasdryingofwaterleakageevents,airleakagecondensation,builtinmoisture,andsusceptibilityofdifferentbuildingmaterialstomoisturerelatedissues.Thedurabilityassessmentwillbedeterminedfromhygrothermalmodeling,aswellasqualitativelybasedontheknowledgeandexperienceofbuildingmaterialcharacteristicssuchasvaporpermeability,hygricbufferingcapacity,andsusceptibilitytomoisturerelateddamage.
2.4 Buildability
Buildabilityisakeycomparisoncriterionforpracticalpurposes.Often,thegeneralcontractorandtradeswillinfluencedesigndecisionsbasedontheperceivedcomplexityofdifferentconstructiontechniquesordeviationfromtheirstandardpractice.Anyenclosuresystemanddetailingshouldbebuildableonaproductionleveltoachievethegreatestbenefiteventhoughthetradesareoftenresistanttochangesinconstructionpractices.
Thesusceptibilityoftheenclosuresystemtopoorlyconstructedwatermanagementdetailsandpoorworkmanshipisalsoconsideredinbuildability.Thesimplerasystemistoinstallcorrectly,themorepreferableitistouse.
2.5 Material Use
Materialuseisbecomingacriticaldesignissuebecauseofincreasingconcernsofdepletingresources,andincreasingcostsofmaterialsandenergy.Someconstructionstrategiesusemoreconstructionmaterials,and
Building Science Corporation 42 www.buildingscience.com 30 Forest St. Somerville, MA 02143
theadvantagesofincreasedthermalcontrolshouldbebalancedagainstthedisadvantagesofincreasingthebuildingmaterialsandembodiedenergy.
Atthetimethisreportwaswritten,someinsulations,suchasXPSandclosedcellsprayfoams,havehigherglobalwarmingpotentialthanalternativeinsulations,meaningtheeffectonglobalwarmingcanbetwoordersofmagnitudegreaterthanotherinsulationstrategies.ThesesignificantglobalwarmingpotentialsarecausedbytheuseofchemicalsusedintheproductionoftheinsulationsuchasHFC‐142b,HFC‐134a,andHFC‐245fa.Thesechemicalhavebetween1000and2000timesmoreglobalwarmingpotentialthanCarbondioxidemeaningthatonekgofHCFC‐142bis2000timesworseforglobalwarmingthan1kgofCO2.
Researchisbeingdonetoreducetheglobalwarmingpotentialinmanycases,andchangesarebeingmadeintheindustry,sospecificinsulationsshouldbereviewedonacasebycasebasisbeforebeingusedtodeterminetheirglobalwarmingpotential.
Embodiedenergyisthetotalenergyrequiredtogetaspecificproducttotheconstructionsiteincludingallenergytoobtaintherawmaterials,processingenergyandtransportationenergy.Insomecases,materialsthathavelessembodiedenergy,orrecycledmaterial,suchascelluloseinsulationcouldbeusedinsteadofthemoreenergyintensiveinsulations.Materialsthatareproducedlocallyrequirelessshippinganddecreasetheembodiedenergyrequired.
2.6 Cost
Thefactorwhichgenerallyhasthegreatestinfluenceonimplementationofabuildingenclosurestrategy,particularlyforproductionbuilders,iscost.Becausethecostofsomematerialsvariessignificantlydependingonlocationandcase‐specificrelationshipsbetweenbuildersandsuppliers,thecostofabuildingenclosuresystemwillbeperceivedrelativetoothersystems.Whendecidingwhichrecommendedsystemtouse,somecostestimatesshouldbedeterminedforyourlocale.
2.7 Other Considerations
Thereareoftenfactors,suchasoccupancycomfortandhealththatdonotquitefitintheothercategories,butareratheracombinationoftheothercomparisoncriteria.Onehealthrelatedcriteria,generallyassociatedwithbasementsisradongas.Radonprotectionisnotdealtwithinthisreport,butduringconstruction,itisveryeasytoinstallcomponentsthatwillmakeradonprotectionsimpleinthefutureshouldradonbeanissue.Infact,somerecommendedmeasurestakentoincreasethethermalresistanceofabasementassemblycanbedetailedtobepartofapassiveradonsystem.Forexample,thesubslabgravelbed,whichhasbeenidentifiedasacapillarybreakinthisreport,alsoservesthepurposeofcollectingsoilgasifaventstackisalsoinstalledduringconstruction.Also,detailingairbarriersysteminacontinuousmannerthroughthefoundationassembliesincreasesthethermalperformanceandblockssoilgasinfiltration.
Insomegeographicareas,somelevelsofradonprotectionwillberequiredinnewconstructionunderthebuildingcodeinthenearfuture.MoreinformationaboutradonandsoilgasresistantconstructioncanbefoundontheUSEPA’swebsite(http://www.epa.gov/radon/).
Building Science Corporation 43 www.buildingscience.com 30 Forest St. Somerville, MA 02143
C.Results 1. CASE 1 : UNINSULATED FOUNDATION WALLS AND SLAB
TheuninsulatedbasementcasewasincludedinthisanalysisbecausethereareuninsulatedbasementsinexistenceeventhoughthecoderequirementsinDOEclimatezones4andhigherdonotallowanuninsulatedbasementinnewconstructionwherethebasementisconditioned.Theuninsulatedbasementwasincludedasabaselineforcomparisonpurposes.
Figure 34 : Uninsulated Basement
1.1 Thermal Control
Thereisnothermalcontrolinthefoundationwallsorslab.Thisresultsinhighenergylossesformostoftheyear.Significantwholehouseenergysavingscanbeexperiencedifthebasementisinsulatedbutcareshouldbetakentodesignthethermalcontrolappropriatelytotheconstructiontypetodecreasetheriskofmoisturerelatedissuesfollowinganenergyretrofit.Predictedannualheatingenergylossbasedontheselectedsimulationcriteriais57MBtus.
1.2 Moisture Control
Sincethereisnoinsulation,thereislikelynomoisturecontrolinthebasement.Watervaporfromtheexteriorisaconstantmoisturesource,andcapillarywickingthroughthefootingand/orfoundationwallmayalsobeasignificantmoisturesourceincreasingtheriskofmoisturerelatedissues.
Building Science Corporation 44 www.buildingscience.com 30 Forest St. Somerville, MA 02143
WUFIanalysisoftheuninsulatedbasementintheHygrothermalanalysissectionshowednosignificantmoisturerelatedissues(Figure13andFigure14),iftherelativehumidityiscontrolledwithadehumidifier,althoughthebasementwilllikelystillsmelldampandmusty.
1.3 Constructability and Cost
Thereisnoconstructioncosttoleavingthebasementuninsulated,buttherearesignificantlyhigherenergycosts.
1.4 Other Considerations
Itisnotrecommendedtoleavethebasementuninsulatedfromanenergy,comfort,andhealthperspective.Therearemanydifferentretrofitstrategiesthatcouldbeused,someofwhichareincludedinthisanalysis.
Building Science Corporation 45 www.buildingscience.com 30 Forest St. Somerville, MA 02143
2. CASE 2 : CODE MINIMUM R10 CONTINUOUS INSULATION
AccordingtotheIECC,newresidentialconstructionofconditionedbasementsinDOEclimatezones4andgreatermustbeconstructedwithcontinuousR10insulationorR13inaframedwall.ContinuousR‐10istypicallyinstalledbyapplyingarollbattdirectlytothefoundationwallwhichconsistoffiberglassbatt.Insomeareas,therollbattiscoveredwithapolyethylenevaporbarrier,aswassimulatedinthehygrothermalanalysis.IntheIRC,therehavebeenimprovementstothebuildingcodewhichdonotrecommendaClassIorIIvaporcontrollayersinthebasementoronthebelowgradeportionofanywall.Commonlyaperforatedfacerisusedwhichisvaporandairpermeable.
Figure 35 : Typical Basement Insulation Strategy
2.1 Thermal Control
TheinstallationofR10continuousinsulation,evenasarollbatt,hassignificantenergyimprovementsoveruninuslatedfoundations,withsavingsofapproximately31MBtus(morethanhalfofanuninsulatedbasement)accordingtosimulations.Rollbattisusedbecauseitisveryinexpensiveandmeetscode,althoughthereareotheralternativesthatpeformbetter,asshowninsomeofthefollowingcases.Thesealternativesaremoreexpensiveforthecontractor,andhomeownersareunawareofthebenefits.
2.2 Moisture Control
Therearemoistureissueswiththisinsulationstrategythatareevidentbothinfieldinvestigationsandsimulations.Fiberglassbattisairandvaporpermeable,somoistureandaircanmovethroughtheinsulation.
Building Science Corporation 46 www.buildingscience.com 30 Forest St. Somerville, MA 02143
AscanbeseeninFigure15,therelativehumidityagainsttheconcretefoundationwalliselevatedthroughtheentireyear.Ifthereisairleakage(orthefacerisairpermeable)thereiscondensationpotentialontheconcretefoundationthroughmostoftheyearasshowninFigure16.Becausethesesimulationsareonedimensional,theyaregoodapproximations,butheatflowinthefoundationwallisthreedimensional.Also,intheairpermeableinsulation,convectiveloopingislikely,whichmayincreasethecondensationabovepredictedresults.Fieldinvestigationsshowthatitisquitecommontogethighquantitiesofmouldinthiswallsystem
2.3 Constructability and Cost
Thisisthemostinexpensivealternativeintermsofinitialcapitalcost,whichisthereasonitischosen.Continuousrollbattmakesfinishingthebasementwithgypsumboarddifficult,unlesstherollbattisremoved.
2.4 Other Considerations
Thiswallisnotrecommendedbasedonthisanalysis,otherreports,andfieldinvestigationsofmouldybasements.
Building Science Corporation 47 www.buildingscience.com 30 Forest St. Somerville, MA 02143
3. CASE 3 : R13 FIBERGLASS BATT IN A 2X4 FRAMED WALL
Case3isasecondalternativetotheminimumcoderequiredbasementinsulationinDOEclimatezones4andhigher.Thisconstructionusesa2x4framedwallagainsttheconcretefoundationwithR13battsinthestudspace.Thehygrothermalsimulationandapolyethylenevaporbarrierontheinterior.
Figure 36 : Case 3 - 2x4 framed wall with fiberglass batt
3.1 Thermal Control
ThisconstructiontechniqueperformsverysimilarlytoCase2.Theparallelpathmethod,takingintoaccountthehigherconductivityoftheframingmembersat24”oncenterresultsinaR‐valueinsidetheconcretewallofR12.6.Thisresultsinatotalannualpredictedheatingenergyloss23.9MBtus,asavingsof32.8MBtus.
3.2 Moisture Control
ThisinsulationstrategyhasaverysimilarpoormoisturecontrolleveltoCase2.Moistureisconstantlymovingfromthebelowgradeexteriorportionofthefoundationwalltotheinterior,andbecomingtrappedintheframedwallcavity.Therelativehumidityiselevatedandcondensationisalmostguaranteedbothontheconcretewallandonthepolyethylenevaporbarrierthroughouttheyear(Figure15).Ifthereisairleakage(orthefacerisairpermeable)thereiscondensationpotentialontheconcretefoundationthroughmostoftheyearasshowninFigure16.Becausethesesimulationsareonedimensional,theyaregoodapproximations,butheatflowinthefoundationwallisthreedimensional.Also,intheairpermeableinsulation,convective
Building Science Corporation 48 www.buildingscience.com 30 Forest St. Somerville, MA 02143
loopingislikely,whichmayincreasethecondensationabovepredictedresults.Fieldinvestigationsshowthatitisquitecommontogethighquantitiesofmouldinthiswallsystem
3.3 Constructability and Cost
ThiswallisslightlymoreexpensivethanCase2becauseoftheframinglumberrequiredbutdoeshavetheaddedbenefitofbeingabletofinishiteasierbyaddingservicesanddrywalleasier.
3.4 Other Considerations
Thiswallconstructiontechniqueisnotrecommended,becauseoftheobviousmoisturerelateddurabilityissuesobservedinthefield,andshownbysimulations.Thewoodframinginthiswallisatriskofmouldandrotafterprolongedexposuretotheconditionspredictedinthewallsystem.
Building Science Corporation 49 www.buildingscience.com 30 Forest St. Somerville, MA 02143
4. CASE 4 : 1” XPS, 2X4 WOOD FRAMED WALL WITH FIBREGLASS BATT
Thisinsulationstrategyissimilartocase3butwiththeaddedinsulationvalue,andmoisturecontrol,of1”ofXPSbetweentheframedwallandconcretefoundationwall.
Figure 37 : Case 4 - 1"XPS and 2x4 framed wall with fiberglass batt
4.1 Thermal Control
ThiswallhasaparallelpathcalculationmethodofR18becausethethermalbridgingoftheframedwallisminimized,theoverallimprovementinRvalueisR5.4foroneinchofR5insulation.Adding1”ofXPSresultsinanenergysavingsof2.2MBtuoverCase3withoutaninchofXPS,butwillalsoreduceconvectiveloopingbecausethetemperaturegradientintheframedwallisless.
4.2 Moisture Control
Thegreatestbenefittoadding1”ofXPSisarguablyformoisturecontrolandnotthermalcontrol.XPScontrolstheflowofwatervaporfromtheconcretetotheframedwall,frombothvapordiffusionthroughtheconcreteandcapillarywickingupthewall,reducingtherelativehumidityinthewallcavity.Smallamountsofmoisture(toosmalltodrain)betweentheXPSandconcreteisirrelevantbecauseneitherconcreteorXPSissusceptibletomoistureissues.TheXPSmustbewellattachedtotheconcretefoundation,andsealed,soairisnotabletobypasstheXPSinsulation.
Building Science Corporation 50 www.buildingscience.com 30 Forest St. Somerville, MA 02143
TheXPSinsulationalsoincreasesthetemperatureofthecondensationplane,minimizingcondensationofelevatedinteriorrelativehumidity.Figure19showsthatthereisstillpotentialformoisturecondensationbutitissignificantlylessthanCase3.
Figure18showstherelativehumiditylevelsattheinteriorsurfaceoftheXPSwhicharesignificantlylowerthanthesurfaceoftheconcreteinCase3.Therelativehumidityisshowntobeafunctionofthevaporcontrolontheinteriorsurface,withvaporbarrierpaint(approx1perm)performingbetterthanlatexpaintorapolyvaporbarrier.Evenwithjustlatexpaint,theriskofmoistureissuesisminimal,iftherelativehumidityinthebasementiscontrolled.
4.3 Constructability and Cost
Theconstructabilityofthiswallsystemisnotdifficult,butcareshouldbetakenthatairisunabletogetbehindtheXPS.Thiscouldbeaccomplishedwithtape,caulking,cansofsprayfoamoracombinationofthethree.Itisnotlikelythattapewillmaintainagoodairsealforthedesiredlifetimeofthewallsystem.ThiswallperformssignificantlybetterthanCase3,atonlyasmallincreasedcost.
4.4 Other Considerations
ThiswallconstructionisanimprovementoverCases2and3,butthereareevenbetteroptionsforthermalandmoisturecontroldiscussedinthefollowingCases.Thisisanaffordableoptionthatmanypeoplecoulddothemselves,withsignificantlylessmoisturerelatedrisksthanCases2and3,resultinginamorecomfortableandhealthyspace.
Building Science Corporation 51 www.buildingscience.com 30 Forest St. Somerville, MA 02143
5. CASE 5 : 2” XPS, 2” FOIL FACED POLYISOCYANURATE
Whenconstructingwithplasticboardfoams,thebuildingcodesrequirethatthefoamnotbeleftexposedasafirehazard.Thermalbarriersarerequiredoverbothboardfoamsandsprayfoamsinmanycases.Thermax™fromDowisathermallyratedfoamboardinsulationthatcanbeleftexposedandcouldbeusedinthissystem.Gypsumboardcouldalsobeusedtocovertheinsulation,butinsomegeographicareas,gypsumboardcanonlybeinstalledifthebasementiselectricallywiredtomeettheelectricalcode,whichdrivesupcostsubstantially.
Figure 38 : Case 5 – 2” XPS, 2” foil faced polyisocyanurate (Recommended)
5.1 Thermal Control
ThisproposedwallsystemperformsverywellthermallyatapproximatelyR23,andincombinationwithunderslabinsulationandthermalbreakattheslabedgeasshowninFigure38,thepredictedannualheatingenergylossis15.8MBtus,animprovementof40.8MBtusoveranuninsulatedwallforthecasestudyhouse.
5.2 Moisture Control
Providedthataircannotbypasstheinsulationlayers,thisstrategywillnotexperienceanymoisturerelatedissuesfromvapordiffusion,orcapillarywicking.Capillarywickingislimitedbythethermal/capillarybreakattheedgeoftheslab,andspecifiedontopofthefooting.
Building Science Corporation 52 www.buildingscience.com 30 Forest St. Somerville, MA 02143
5.3 Constructability and Cost
Theseamsinthetwolayersoffoaminsulationshouldbeoffsetandwellsealed.Athermalbarrierisrequiredbycodeinmostjurisdictions.Thermax™byDowisafoilfacedpolyisocyanurateinsulationthatiscodecompliant.
Tofinishthebasement,drywallwouldbeadded,whichobviatestheneedforfirecontrolinthefoam.
5.4 Other Considerations
Astudwallwillstillneedtobeconstructedtofinishthisbasementwithservicesanddrywall,soifthelongtermplanistofinishbasement,thisproposedwallsystemmaynotbethemosteconomicalchoice.
Insteadofusingtwodifferentboardfoaminsulations,itcouldbeconstructedwithtwolayersofPIC,ortwolayersofXPSwithdrywallinteriorfinish.
Thisbasementinsulationstrategyisrecommendedasadurable,comfortable,andhealthybasementsystem.
Building Science Corporation 53 www.buildingscience.com 30 Forest St. Somerville, MA 02143
6. CASE 6 : 3.5” 2.0 PCF CLOSED CELL SPRAY POLYURETHANE FOAM
AsshowninFigure39,thesprayfoamcanbeapplieddirectlytotheconcrete,butaspreviouslymentioned(andspecifiedinthedesigndetails),ifthefoamisleftexposeditwillrequireathermalbarrier,typicallyaspray‐onthermalbarrier.Theotheroptionistobuildastudwallinfrontofthesprayfoamandusegypsumwallboardasthethermalbarrier.
Figure 39 : Case 6 – Closed Cell spray foam
6.1 Thermal Control
Closedcellsprayfoamprovidesverygoodcontinuousthermalcontrol.Sprayfoamisanairbarrier,soconvectiveloopingandairleakagethermallossesdonotoccur.ThiswallsystemhasanR‐valueofR21andapredictedannualheatingenergylossof16.4MBtus.Morethermalcontrolcouldeasilybeaddedbysprayingmorefoamagainstthewall.
6.2 Moisture Control
Becauseclosedcellsprayfoamisanairandvaporbarrier,therearenoriskstoairleakageorvapordiffusioncondensation.Theconcreteisunabletodrytotheinteriorthroughclosedcellsprayfoam,butconcreteisgenerallynotaffectedbyahighmoisturecontent.Figure21showstherelativehumidityinthemiddleofthefoamdoesnotexceed80%,whichmeanstherearenomoisturerelatedrisksfromvapordiffusion.
Building Science Corporation 54 www.buildingscience.com 30 Forest St. Somerville, MA 02143
6.3 Constructability and Cost
Inthisproposedwallsystem,itispossibletoembedtheframingmembersinthefoam(similartoCase10,toincreasetheinteriorspace.Theframingshouldnotbeincontactwiththefoundationwalltolimitthermalbridging,andpotentialmoisturerelatedissueswiththeframingmembers.Closedcellsprayfoamcanbemoreexpensivethanotheroptions,butreduceslabourtimeoversomeoftheotherwalls,andisappliedbyaskilledlabourersothesystemisverydurableasalongtermsolution.
Sprayonthermalbarrierscanaddsignificantcosttothesprayfoaminstallation,butareregionspecific.
Closedcellsprayfoaminstalledontheinterioroftheconcretefoundationwallistheeasiestandsafestwaytoretrofitanexistingbasement.Sprayfoamcanbeinstalledincombinationwithadrainagemattandinteriordrainagetileinbasementsthathaveliquidwateringressissues.
6.4 Other Considerations
Sprayfoamshavebeenimprovedconsiderablyforhumanhealthandtheenvironment.Ozonedepletingsubstancesintheprocesshavebeenremoved,butsomesprayfoamsusegreenhousegasesthataremuchworsethancarbondioxide.Thereareoptionsavailableofmoreenvironmentallyfriendlysprayfoamsthatdonotreleasegreenhousegases,suchaswaterblownfoams,onthemarketandshouldbeconsidered.
Building Science Corporation 55 www.buildingscience.com 30 Forest St. Somerville, MA 02143
7. CASE 7 : 6” 0.5 PCF OPEN CELL SPRAY FOAM
AsshowninFigure40,opencellsprayfoamcanbeapplieddirectlytotheconcrete,butaspreviouslymentioned(andspecifiedinthedesigndetails),ifthefoamisleftexposeditwillrequireathermalbarrier,typicallyaspray‐onthermalbarrier,orthebasementcanbefinishedwithdrywall.
Figure40showsXPSorfoil‐facedpolyisocyanurateinstalledontheinterioroftherimjoistandfoundationwall.TheWUFIsimulationsforthefoundationwallwereconductedwithoutthislayerofboardfoaminMinneapolis,anditwasfoundthattherewerenomoisturerelatedissues,inpartbecausetheconcreteisnotassusceptibletomoisture.Installingboardfoamonthefoundationwallwillfurtherincreasethefactorofsafetyoverthepredictedresultsandmayberequiredincolderclimates.Therimjoistwasnotsimulatedinthisstudy,sinceitwassimulatedpreviously,butbecauseofthesusceptibilityofthewoodtomoisturerelateddurabilityissues,andthevaporpermeanceofthefoam,itisrecommendedtousetheboardfoamattherimjoisttolimitvapordiffusionandincreasethetemperatureofthepotentialcondensationsurface.
Figure 40 : Case 7 – Open Cell Spray Foam (Recommended)
7.1 Thermal Control
Opencellsprayfoamprovidesverygoodcontinuousthermalcontrol.Sprayfoamisanairbarrier,soconvectiveloopingandairleakagethermallossesdonotoccur.ThiswallsystemhasanR‐valueofR21andapredictedannualheatingenergylossof15.8MBtus.
Building Science Corporation 56 www.buildingscience.com 30 Forest St. Somerville, MA 02143
7.2 Moisture Control
Opencellsprayfoamisanairbarrier,butisvaporpermeable.Figure40showstheXPSinsulationdetailrequiredattheabovegradeportionofthefoundationwallforcoldclimateconstructiontominimizemoisturecondensationatthecoldconcreteinthewintermonths,andminimizeinwarddrivenvaporinthesummermonths.
Therelativehumiditywaspredictedinthecenteroftheopencellsprayfoaminsulationandwasfoundtobeatsafelevels(Figure24).
Lowpermeanceinteriorwallfinishes(<ClassIII)shouldbeavoidedwiththisconstructionstrategysothematerialcharacteristicsofthesprayonthermalbarriermustbeconsidered.
7.3 Constructability and Cost
Opencellsprayfoamislessexpensivethanclosedcellsprayfoambutdoesdecreasetheinteriorusefulspaceandvaporcontrolshouldbeconsideredforthissystem.
Thisproposedwallsystemdoesnotallowforfinishingofthebasementwithoutinstallinganinteriorframedwall.Ifthelongtermgoalistofinishtheinteriorofthebasement,Case10shouldbeconsideredinstead.
Sprayonthermalbarrierscanaddsignificantcosttothesprayfoaminstallation,butareregionspecific.
7.4 Other Considerations
Thisisarecommendedwallconstructionprovidedthatthedetailsforcoldclimatesarefollowed,includinganextralayerofvaporcondensationprotectionfortheabovegroundportionofthewall.
Sprayfoamshavebeenimprovedconsiderablyforhumanhealthandtheenvironment.Ozonedepletingsubstancesintheprocesshavebeenremoved,butsomesprayfoamsusegreenhousegasesthataremuchworsethancarbondioxide.Thereareoptionsavailableofmoreenvironmentallyfriendlysprayfoamsdonotreleasegreenhousegases,suchaswaterblownfoams,onthemarketandshouldbeconsidered.
Building Science Corporation 57 www.buildingscience.com 30 Forest St. Somerville, MA 02143
8. CASE 8 : 2” XPS, 2X4 FRAMING WITH FIBREGLASS BATT
Figure 41 : Case 8 – 2”XPS, 2x4 framing with fiberglass batt
8.1 Thermal Control
ThiswallsystemhasaninstalledinsulationR‐valueofR23whichisonlyslightlylowerbasedontheparallelpathcalculationmethodwhichaccountsforthewallframingassuming24”oncenter.ThisbasementcombinedwithR10undertheslabandR10thermalbreakresultsinanannualpredictedheatingenergylossof15.8MBtufortheexamplehouse.
8.2 Moisture Control
Thewatervapordiffusionandcapillarywickingarecontrolledby2”ofXPSinsulationassumingthattheXPSiswellsealedtotheconcrete.ThiswallsystemwasnothygrothermallysimulatedsinceitwillperformbetterthanCase14fromamoisturepointofview,andCase14performedwell.Case14has5.5”offiberglassbattinsulationwhichwillresultincoldercondensationplane.Case14hadsomecondensationpotentialbutimprovedperformancewithavaporretardingpaint.Therewassomepotentialforairleakagecondensationattheabovegradesectionofthewallinthewinteralternatingwithdryingperiods.
8.3 Constructability and Cost
Itmaybedifficulttoget2”boardsofXPSattachedwelltothenonuniformsurfaceoftheconcretefoundationbecausetheinsulationissostiff.Itiseasierinsomecasestouse21”thickboards,thatwillflexoverimperfections.Thejointsintheinsulationshouldbeoffsetiftwolayersof1”XPSareused.
Building Science Corporation 58 www.buildingscience.com 30 Forest St. Somerville, MA 02143
8.4 Other Considerations
Case8isoneofthesimplestandleastexpensivemethodsofminimizingthemoistureriskandsavingenergy.Itispossibletouseotherairpermeableinsulationsinsteadoffibreglassbattincludingdampspraycellulose,orsprayfibreglass.
9. CASE 9 : 2” POLYISOCYANURATE INSULATION, 2X4 FRAMING WITH CELLULOSE
Figure 42 : Case 9 – 2” polyiso, 2x4 framing with cellulose
9.1 Thermal Control
ThiswallsystemhasaninstalledinsulationR‐valueofR25whichisonlyslightlylowerbasedontheparallelpathcalculationmethodwhichaccountsforthewallframingassuming24”oncenter.ThisbasementcombinedwithR10undertheslabandR10thermalbreakresultsinanannualpredictedheatingenergylossof15.45MBtus.
9.2 Moisture Control
Thewatervapordiffusionandcapillarywickingarecontrolledby2”ofPICinsulationassumingthatthePICiswellsealedtotheconcrete.Thiswallsystemwasnothygrothermallysimulatedsinceitwillnotexperienceanymoisturerelatedissues.Thefoilfaceonthepolyisocyanuratewillnotallowvapordiffusionfromtheconcretefoundation,andtheincreasedR‐valueofPICcomparedtoXPSwillincreasethecondensationsurfacetemperaturecomparedtoCase8andCase14,resultingindecreasedcondensationpotential.
Building Science Corporation 59 www.buildingscience.com 30 Forest St. Somerville, MA 02143
9.3 Constructability and Cost
Fiberglassbattinsulationcouldbeusedintheplaceofcellulosetodecreasethecostoftheassembly.
9.4 Other Considerations
Case8isoneofthesimplestmethodsofminimizingthemoistureriskandsavingenergywhichalsoallowsthebasementtobefinished.Itispossibletouseotherairpermeableinsulationsinsteadofcelluloseincludingfiberglassbattorsprayfiberglass.
10. CASE 10 : 6” 0.5 PCF SPRAY FOAM WITH 2X4 FRAMING OFFSET 2.5” FROM CONCRETE
Figure 43 : Case 10 – 6” open cell foam
10.1 Thermal Control
Opencellsprayfoamprovidesverygoodcontinuousthermalcontrol.Sprayfoamisanairbarrier,soconvectiveloopingandairleakagethermallossesdonotoccur.ThiswallsystemhasanR‐valueofR21andapredictedannualheatingenergylossof16.3MBtus.
10.2 Moisture Control
Opencellsprayfoamisanairbarrier,butisvaporpermeable.Therelativehumiditywaspredictedinthecenteroftheopencellsprayfoaminsulationandwasfoundtobeatsafelevels(Figure24).
Building Science Corporation 60 www.buildingscience.com 30 Forest St. Somerville, MA 02143
Lowpermeanceinteriorwallfinishesshouldbeavoidedwiththisconstructionstrategy.
10.3 Constructability and Cost
ThissolutionismorepracticalthanCase7iftheplanistofinishtheinteriorofthebasement.
10.4 Other Considerations
Sprayfoamshavebeenimprovedconsiderablyforhumanhealthandtheenvironment.Ozonedepletingsubstancesintheprocesshavebeenremoved,butsomesprayfoamsusegreenhousegasesthataremuchworsethancarbondioxide.Thereareoptionsavailableofmoreenvironmentallyfriendlysprayfoamsthatreleasegreenhousegases,suchaswaterblownfoams,onthemarketandshouldbeconsidered.
11. CASE 11 : 4” XPS INSULATION ON THE EXTERIOR OF FOUNDATION WALL
Figure 44 : Case 11 – Exterior XPS insulation
11.1 Thermal Control
ThisproposedwallsystemhasaninstalledinsulationR‐valueofR20andresultsinheatingenergylossof19.43MBtusforthespecificchosenparameters.Theadvantageofinsulatingontheexterioristhattheinsulationontheexteriorofthefoundationcanbejoinedwiththeexteriorinsulationonthefirstfloor,whichformsacontinuouslayerofinsulationandvaporcontrol.Thethermaldisadvantageofthissystemisthatthereisathermalbridgethroughtheconcretewall,andfootingintotheground.
Building Science Corporation 61 www.buildingscience.com 30 Forest St. Somerville, MA 02143
11.2 Moisture Control
FourinchesofXPSisagreatvapordiffusionresisterandcapillarybreakforinwardmoisturemovement.Thereisstillcapillarywickingpotentialthroughthefootingintotheinteriorsurfaceofconcreteresultinginmoistureattheinteriorsurfaceevaporatingintotheinteriorspaceifitisnotdetailedcorrectly.Thispotentialmoistureissuecanbesolvedbyusingacapillarybreak(eitherliquidappliedorplasticbased)onthetopofthefootingasnotedinthedesigndetails.Unlikesomeoftheotherproposedfoundationwallsystems,theexposedconcreteinthissystemwillprovidemoisturebufferingcapacity,onceithasdried.
11.3 Constructability and Cost
Thisproposedwallsystemwithexteriorinsulationisperceivedasdifficulttotheconstructiontrades,andthefinishingoftheabovegradeportionmaynotbearchitecturallydesirable.Insomecasesthetimingoftheinsulationinstallationtradescanbetrickysincetheentirehouseisnotinsulatedatonceinthiscase.
11.4 Other Considerations
Insomecases,exteriorfoundationisnotallowedbythebuildingcodeduetocomplicationswithtermitesandotherinsects.Whereinsectsmaybeanissue,Case12proposedwallsystemcouldbeused.
12. CASE 12 : 4” XPS INSULATION IN THE CENTER OF FOUNDATION WALL
Figure 45 : Case 12 – Interstitial XPS Insulation
Building Science Corporation 62 www.buildingscience.com 30 Forest St. Somerville, MA 02143
12.1 Thermal Control
ThisconstructionstrategyhasaninstalledinsulationR‐valueofR20,andhasapredictedannualheatingenergylossof19.24MBtus.Unlikesomeoftheotherwallsystemstheremaybethermalmassbenefitsoftheinteriorexposedsurfaceofconcrete.Thereisasmallthermalbridgethroughthefootingandinteriorsurfaceofconcretethatdoesincreasetheenergyrequiredoverawallthatisinsulatedcompletelyontheinterior
12.2 Moisture Control
FourinchesofXPSisagreatvapordiffusionresisterandcapillarybreakforinwardmoisturemovement.Thereisstillcapillarywickingpotentialthroughthefootingintotheinteriorsurfaceofconcreteresultinginmoistureattheinteriorsurfaceevaporatingintotheinteriorspaceifitisnotdetailedcorrectly.Thispotentialmoistureissuecanbesolvedbyusingacapillarybreak(eitherliquidappliedorplasticbased)onthetopofthefootingasnotedinthedesigndetails(Figure45).Unlikesomeoftheotherproposedfoundationwallsystems,theexposedconcreteinthissystemwillprovidemoisturebufferingcapacity,onceithasdried.
12.3 Constructability and Cost
Thisconstructionstrategyisnotverycommon,butisverydurablebecausetheXPSissealedintotheconcreteandprotectedfrominteriorandexteriordamage.Thiswalldesignismoreexpensivethaninstalling4”ontheinteriorortheexterior.
12.4 Other Considerations
Thisproposedwalltypemaynotbelocallyavailable.
Building Science Corporation 63 www.buildingscience.com 30 Forest St. Somerville, MA 02143
13. CASE 13 : INSULATED CONCRETE FORMS, 2” XPS ON INTERIOR AND EXTERIOR
Figure 46 : Case 13 –Insulated Concrete Forms (ICF)
13.1 Thermal Control
ThisconstructionstrategyhasaninstalledinsulationR‐valueofR20,andhasapredictedannualheatingenergylossof16.7MBtus.
13.2 Moisture Control
TwoinchesofXPSontheinterior,connectedtothethermalbreakattheslabedge,controlstheinteriorvapordriveandcapillarywickingtotheinteriorsotherearenomoisturerelatedissuesfrominwardvapordiffusionorcapillarywicking.
13.3 Constructability and Cost
Theinterioroftheinsulatedconcreteformwillrequiredrywallorotherthermalbarriertoachievethefireratingrequiredbycode.ThegypsumboardisveryeasytoattachtotheplasticclipsdesignedintotheICF.Thedrywallshouldnotbepainted,ifitisnotnecessary,toallowmaximumdryingoftheconcrete.Itmaybeeasierandmorepracticaltoinstallathinframedwall(eg.2x3woodorsteelframing)ontheinterioroftheICFtoallowanynecessaryservicestoberuninthewall,andpotentiallymoreinsulation.
Building Science Corporation 64 www.buildingscience.com 30 Forest St. Somerville, MA 02143
13.4 Other Considerations
Becausetheconcreteisinstalledbetweentwovaporretardinglayers,itwilltakeseveralyearsfortheconcretetodrytoequilibrium.Sinceadditionalinteriorvaporcontrolshouldbeavoided,nomorethanlatexpaintshouldbeusedontheinteriorsurfaceofthedrywall.
14. CASE 14 : 2” XPS, 2X6 FRAMING WITH FIBREGLASS BATT
Figure 47 : Case 14 – 2”XPS, 2x6 framing with fiberglass batt
14.1 Thermal Control
ThisfoundationwallsystemhasacalculatedparallelpathR‐valueofR28.7,andayearlyheatingenergyconsumptionof14.79MBTusassumingR10undertheslabandinthethermalbreak.Onlyiftherestoftheenclosureissuperinsulated,andairtight,inaverycoldclimatewillitmakesensetoincreasetheR‐valueofthefoundationwall.ItmaymakesensewithanR30foundationwalltoincreasetheunderslabinsulationtoR15orR20.Thisshouldbeexaminedinmoredetail.
14.2 Moisture Control
ThiswallwasanalyzedinWUFItopredictthemoisturerelatedriskinthewallsystem,anditwasshownthattheRHatthesurfaceoftheXPSintheabovegradeportionofthewalliselevatedinthewintermonths(Figure28),andthatthereissomecondensationpotentialalternatingwithperiodsofdryingpotentialatthetopofthefoundationwall.(Figure27).ThereislittleriskofmoisturerelatedissuesinthisallsystemiftheinteriorRHiscontrolledwithadehumidifier,andtheinteriordrywalliswellairsealed.
Building Science Corporation 65 www.buildingscience.com 30 Forest St. Somerville, MA 02143
14.3 Constructability and Cost
ThiswallsystemisslightlymoreexpensivethanCases8and9byincreasingthedepthoftheframedcavitywith2x6framinginsteadof2x4framing.Itispossibletouse2x4framingstoodoutfromtheXPSby2inches,anduseR19fiberglassbatts,orblowncelluloseorfibreglass.R19fiberglassbattsshouldbelessexpensivethanR13fiberglassbattsbecausethemanufacturingprocessforbothR19andR13battsusesthesameamountoffibreglass,buttheR13battsrequiremoretimeandefforttocompactto3.5”makingthemmoreexpensivetoproduce.
14.4 Other Considerations
15. CASE 15 : 4” PIC, 2X6 FRAMING WITH FIBREGLASS BATT
Figure 48 : Case 14 – 2”XPS, 2x6 framing with fiberglass batt
15.1 Thermal Control
ThisfoundationwallsystemhasacalculatedparallelpathR‐valueofR45.0,andayearlyheatingenergyconsumptionof11.09MBTusassumingR20undertheslabandinthethermalbreak..ThisisthehighestRvaluefoundationsysteminthisstudy,andislikelynotcosteffectiveunlesstherestofthehouseissuperinsulatedandairtight.
15.2 Moisture Control
ThiswallwasanalyzedinWUFItopredictthemoisturerelatedriskinthewallsystem,anditwasshownthattheRHatthesurfaceoftheXPSintheabovegradeportionofthewallisslightlyelevatedinthewinter
Building Science Corporation 66 www.buildingscience.com 30 Forest St. Somerville, MA 02143
months(Figure31),butdoesnotexceed90%.Thereisalmostnocondensationpotential(Figure32)exceptontheupperwallofthenorthorientationfortwoveryshortperiods.ThereisvirtuallynoriskofmoisturerelatedissuesinthisallsystemiftheinteriorRHiscontrolledwithadehumidifier,andtheinteriordrywalliswellairsealed.
15.3 Constructability and Cost
ThiswallsystemisslightlymoreexpensivethanCases14bychangingthe2”ofXPSto4”offoil‐facedpolyisocyanurate.Itispossibletouse2x4framingstoodoutfromtheXPSby2inches,anduseR19fiberglassbatts,orblowncelluloseorfibreglass.R19fiberglassbattsshouldbelessexpensivethanR13fiberglassbattsbecausethemanufacturingprocessforbothR19andR13battsusesthesameamountoffibreglass,buttheR13battsrequiremoretimeandefforttocompactto3.5”makingthemmoreexpensivetoproduce.
15.4 Other Considerations
Dependingonsitespecificconditions,andlocalcosts,thiswallislikelynoteconomicaltobuildunlessthehouseisveryhighlyinsulatedandairtight.
Building Science Corporation 67 www.buildingscience.com 30 Forest St. Somerville, MA 02143
D.Conclusions HeatingenergylosscalculationsforalloftheassemblieswerecalculatedusingBasecalcandthesummaryisshowninTable5below.TheheatingenergylosseswereconductedforabasementinMinneapolis(DOEclimatezone6),withanareaof1614ft2.
Table 5 : Summary of Basecalc Results
Analysisshowedthatevenasmallamountofinsulationonthefoundationwalldecreasedtheheatingenergylossessignificantlycomparedtoanuninsulatedbasement,butthebenefitsofincreasinginsulationdecreaseasmoreinsulationisadded.InCases5through13,noneofthewallsperformsignificantlybetterthantheothersfromaheatingenergylossesperspective,soanydecisionsshouldbebasedoncost,durabilityanddesiredfinish.
Insulatingbelowthebasementslabandattheinterfaceofthefoundationwallandbasementslabwillresultinenergysavings,butthegreatestbenefitismoisturerelatedsincetheyformavapordiffusionandcapillarybreakbetweenthemoistureandtheinteriorenvironment,resultinginadrier,healthierinteriorenvironment.
Besidesbulkwatermovement,whichisnotspecificallyaddressedinthisreport,therearetwomodesofwettinginthefoundation;vapordiffusionandcapillarywetting.Theexteriorsurfaceofthebelowgradeportionofanyfoundationwallismaintainedatapproximately100%relativehumiditysomoisturemovementbelowgradeisalwaystotheinterioranddryingisnotpossibletotheexterior.TheIRChasbeenmodifiedtoreflectthis,notrecommendingaClassIorIIvaporcontrollayerontheinteriorofanybelowgradewall.
Capillarywickingthroughthefootingintothefoundationwallisgenerallynotaddressedbyproductionbuilders,andcanresultinsignificantamountsofmoistureevaporatingfromtheinteriorsurfaceofthebasementwall.
Cases2and3representcodeminimumbasementinsulationamounts,althoughthesewerehygrothermallysimulatedwithaninteriorpolylayerinsteadofaperforatedlayer,whichshouldbesimulatedinfuturework.Withapolyethylenevaporbarrier,thesewallsperformverypoorly,withhighrelativehumiditiesintheinsulation,andairleakagecondensationpotentialfornearlytheentireyear.Intrusiveinvestigationsofbuildingsinthefieldhaveshownthatmoisturerelatedissues(includingmould,rot,andodours)canbeexpectedwiththistypeofwallconstruction.
Building Science Corporation 68 www.buildingscience.com 30 Forest St. Somerville, MA 02143
Cases4,8,9,and14witharigidfoamagainsttheconcretefoundationandairpermeableinsulationinawoodframedwall(fiberglassbattorcellulose)showedsignificantimprovementsinmoistureperformanceoverCase2and3.Thereisstillsomepredictedairleakagecondensationpotential,butgenerallyisolatedtotheabovegradeportionofthewall,duetotheverycoldexteriortemperatures.
Case5with2”ofXPSand2”ofpolyisocyanuratehasnomoisturerelatedissuesandperformsverywell,butdoesnoteasilyallowforinteriorfinishescomparedtosomeotherproposedfoundationinsualationsystems.
Case6,7,and10usesprayfoamapplieddirectlyagainstthefoundationwall,whichformsanairbarriersystemresultinginnoairleakagecondensation.Closedcellsprayfoamisavaporbarrierlimitingdiffusiontotheinteriorandopencellfoamismorevaporpermeable,butsimulationspredictednomoisturerelatedissuesfromvapordiffusionduetothethicknessoffoam,andtheabilityofsmallamountofvaportodrytotheinteriorthroughthefoamandinteriorfinish.Attheabovegradeportionofthewallincoldclimates,alowerpermeanceboardfoamisrecommendedtocontroltheinwardvapordriveinthesummermonths,andlimitthevapordiffusioncondensationinthewintermonths.Therearenomoisturerelatedissuespredictedforthesprayfoamwalls.
Cases11,12,and13areallconstructedwith4”ofXPSindifferentlocationsonthefoundationwall,andallresultingoodmoistureperformance.Acapillarybreakisalwaysrecommendedbetweenthefootingandthefoundationwall,andinCase11,and12,itisrequiredsincethevaporcontrollayer,thatdecreasestheevaporationandvapordiffusionfromtheinteriorsurface,isdiscontinuousontheinteriorsurface.Cases11,and12alsohaveslightlyhigherheatingenergylossesbecauseofthethermalbridgealongtheinteriorsurfaceofthefoundationwallthroughthefooting,buttheydohavetheadvantageofboththermalandmoisturebufferingiftheinterioroftheconcretewallisleftexposed.
Followingtheanalysisofallproposedfoundationwallsystems,valueswereassignedforthefivecomparisoncriteria;
• Thermalcontrol• Durability• Buildability• Cost• Materialuse
Thesewallswerescoredonascaleof1to5foreachcriterion,onebeingtheworst,andfivebeingthebestperforming,andtheresultsareshowninTable6.Basedontheselectedcriteria,thetwohighestscoringwallswereCase6with3.5”of2.0pcfclosedcellspufandCase7with6”of0.5pcfocspf.BecausesomeofthecriteriasuchasMaterialUseandCostcouldbedifferentinotherregions,thefinalresultscouldbedifferentindifferentpartsofthecontinent.
Allofthecriteriaarecurrentlyweightedevenly,buttheycouldbechangeddependingontheconcernsofthecontractororhomeowner.Usingmultipliersbetween1and5beforesummingthescorescouldresultindifferentresultsbasedontheimportanceofdifferentcriteria.
Building Science Corporation 69 www.buildingscience.com 30 Forest St. Somerville, MA 02143
Table 6 : Comparison Criteria Matrix with Scoring Results
E. Future Work Whileconductingthisanalysis,somequestionswereencounteredthatrequirefurtherresearch,analysisandsimulationstomorecompletelyunderstandthemoistureandthermalperformanceofbasementinsulationsystems.Theseareasinclude;
• DeterminingtheeffectofperforatedfacersoncodecompliantR10rollbatts• Researchingfieldtestingdataonbasementmonitoringdatathathasbeenconductedand
correlatetotheproposedwallsystems.• FurtheranalysisoftheMitalasfiniteelementanalysismethodofheatingenergylossfor
basements.• Attempttoquantifytheroleofcapillarywickingthroughthebasementwallrelativetothe
vapordiffusionload.SomeworkhasbeenconductedalreadybyKohtaUenoofBuildingScienceCorporationaspartofaBuildingAmericaFoundationsExpertsGroupMeeting.
FollowingthecompletionoftheHigh‐Rbasementandfoundationreport,ananalysisreportwillbecompletedforroofsandatticsregardinghistorical,codecompliantandsuperinsulatedroofstrategies.Similarlytothe
Building Science Corporation 70 www.buildingscience.com 30 Forest St. Somerville, MA 02143
previousHighRWallReportandthisBasements/Foundationsreport,theRoofandAtticreportwillbeacombinationofbothfieldtesting/monitoring,thermalandhygrothermalanalysis,yearsofexperience.
F. Works Cited Lstiburek,J.UnderstandingBasements,BuildingScienceDigest103,Westford,BuildingSciencePress,2006
Mitalas,G.P.,CalculationofBasementHeatLoss,NationalResearchCouncilCanada
Pettit,B.,RenovatingExistingBasements,ResearchReport–0509c,Westford,BuildingSciencePress,2008
Straube,J.,andBurnett,E.,BuildingScienceforBuildingEnclosures.Westford,BuildingSciencePress,2005
Straube,J.,Smegal,J.,BuildingAmericaSpecialResearchProject:HighRWallsCaseStudyAnalysis,BuildingSciencePress,MA,2009
BA-1003: Building America Special Research Report High-R Foundation Case Study Analysis
About this Report
This report was prepared with the cooperation of the U.S. Department of Energy’s, Building America Program.
About the Authors
Jonathan Smegal’s work at BSC includes laboratory research, hygro-thermal modeling, field monitoring of wall performance, and forensic analysis of building failures.
John Straube teaches in the Department of Civil Engineering and the School of Architecture at the University of Waterloo. More information about John Straube can be found at www.buildingscienceconsulting.com.
Direct all correspondence to: Building Science Corporation, 30 Forest Street, Somerville, MA 02143.
Limits of Liability and Disclaimer of Warranty:
Building Science documents are intended for professionals. The author and the publisher of this article have used their best efforts to provide accurate and authoritative information in regard to the subject matter covered. The author and publisher make no warranty of any kind, expressed or implied, with regard to the information contained in this article.
The information presented in this article must be used with care by professionals who understand the implications of what they are doing. If professional advice or other expert assistance is required, the services of a competent professional shall be sought. The author and publisher shall not be liable in the event of incidental or consequential damages in connection with, or arising from, the use of the information contained within this Building Science document.