Budget Offer: COMPLETE TURBINE GE LMS100 Dear Sir, In ...

26
JERANEAS, S.L. Ronda de Atocha, 37 28012 Madrid - España T international (+34) 911 610 336 M (+34) 697 921 445 Web: www.repoweringsolutions.com Email: [email protected] STRICTLY CONFIDENTIAL SUBJECT TO CONDITIONS OF NON-DISCLOSURE Proposal_economical_GE LMS100_rev101 Page 1 of 14 Date September 11, 2015 Budget Offer: COMPLETE TURBINE GE LMS100 Dear Sir, In response to your enquiry, we are pleased to attach our budget offer for the supply of equipment listed below. The offer is an open offer, for budgetary purposes only and is defined in our technical specification and scope of supply as attached. It is ruled by Spain law. After verification of the respective site specific data, we would be pleased to make you a more detailed firm quotation upon request.

Transcript of Budget Offer: COMPLETE TURBINE GE LMS100 Dear Sir, In ...

Page 1: Budget Offer: COMPLETE TURBINE GE LMS100 Dear Sir, In ...

 

 

JERANEAS, S.L. Ronda de Atocha, 37 28012 Madrid - España T international (+34) 911 610 336 M (+34) 697 921 445 Web: www.repoweringsolutions.com Email: [email protected]

 

STRICTLY CONFIDENTIAL SUBJECT TO CONDITIONS OF NON-DISCLOSURE Proposal_economical_GE LMS100_rev101 Page 1 of 14 Date September 11, 2015

Budget Offer: COMPLETE TURBINE GE LMS100

Dear Sir, In response to your enquiry, we are pleased to attach our budget offer for the supply of equipment listed below. The offer is an open offer, for budgetary purposes only and is defined in our technical specification and scope of supply as attached. It is ruled by Spain law. After verification of the respective site specific data, we would be pleased to make you a more detailed firm quotation upon request.

Page 2: Budget Offer: COMPLETE TURBINE GE LMS100 Dear Sir, In ...

 

 

JERANEAS, S.L. Ronda de Atocha, 37 28012 Madrid - España T international (+34) 911 610 336 M (+34) 697 921 445 Web: www.repoweringsolutions.com Email: [email protected]

 

STRICTLY CONFIDENTIAL SUBJECT TO CONDITIONS OF NON-DISCLOSURE Proposal_economical_GE LMS100_rev101 Page 2 of 14 Date September 11, 2015

SUBJECT

Offer 1 unit GTG PACKAGE LMS100PA

PRICE

EXWORKS PRICE for request

TRANSPORT COST TO FOB BILBAO PORT for package is 1.900.000,00 USD

The above prices exclude VAT or any other taxes, and are binding.

CONDITIONS

All prices quoted in USD

The equipment described is sold “AS IS WHERE IS” WITHOUT WARRANTY. The equipment has zero hours of operation and is available for inspection.

FOB BILBAO PORT, SPAIN

Equipment manufactured in 2008 in Houston-SPAIN and arrival at temporary storage in 2009.

Man equipment stored in controlled environment with optimum temperature and humidity conditions

Optimum packing equipment and structural protections.

The storage have followed a preservation program according to the procedures established for long-term storage by GE consisting of:

Daily inspection of the conditions of temperature and humidity. Weekly inspections of the equipment packing Monthly inspections of the state of the mechanical parts of the equipment’s Video scope biannual inspections of the several parts of the gas turbine

Page 3: Budget Offer: COMPLETE TURBINE GE LMS100 Dear Sir, In ...

 

 

JERANEAS, S.L. Ronda de Atocha, 37 28012 Madrid - España T international (+34) 911 610 336 M (+34) 697 921 445 Web: www.repoweringsolutions.com Email: [email protected]

 

STRICTLY CONFIDENTIAL SUBJECT TO CONDITIONS OF NON-DISCLOSURE Proposal_economical_GE LMS100_rev101 Page 3 of 14 Date September 11, 2015

TERMS OF PAYMENT

100% of the total price receipt of payment shall mean the date of firm placement of order to the client.

SCOPE OF SUPPLY GTG PACKAGE LMS100PA

Gas Turbine GE LMS100PA 3 spool hybrid gas turbine in the LM family:

Low pressure compressor (LPC) Aeroderivative supercore (high pressure compressor, combustor and high pressure

turbine and intermediate pressure turbine) Five stages low pressure turbine turbine (LPT)

Generator

Air cooled Hitachi (model GH1150A) made 2-pole generator rated at min 138,75kVA @ 0.80pf, 15ºC cooling air, 11.500 volts, 50Hz

Gas Turbine Enclosure

Weatherproof acoustic enclosure and a removable roof for quick engine removal and replacement

Turbine Baseplate

Support structure for the gas turbine

Air Inlet System

High efficiency self cleaning filtration system with platforms and ladders to service the inlet filter

Anti-icing system

Anti-icing cooling system based on gas turbine axial compressor bleed air

Intercooler

Intercooler system that includes water cooled heat exchanger, variable bleed valve (VBV), VBV silencer, and interconnect piping and supports.

Page 4: Budget Offer: COMPLETE TURBINE GE LMS100 Dear Sir, In ...

 

 

JERANEAS, S.L. Ronda de Atocha, 37 28012 Madrid - España T international (+34) 911 610 336 M (+34) 697 921 445 Web: www.repoweringsolutions.com Email: [email protected]

 

STRICTLY CONFIDENTIAL SUBJECT TO CONDITIONS OF NON-DISCLOSURE Proposal_economical_GE LMS100_rev101 Page 4 of 14 Date September 11, 2015

Turbine Exhaust

Right-hand (aft looking forward) rectangular exhaust outlet with connection flange to facilitate mounting of the exhaust system

Fuel system

Natural gas system using an electronically controlled fuel-metering valve All necessary shutoff valves, piping and instruments between baseplate connection and

the engine

Water injection for NOx control

Water injection system for NOx emissions limitations consisting of an inlet strainer, pump, motor, valves, piping and controls.

Cooling water pumps skid

Water pumps skid with 2x100% water pumps to supply cooling water to both the gas turbine intercooler and GTG lube oil coolers, and a third pump to supply cooling water to the GTG lube oil coolers during the GTG shutdown.

Lube oil systems Two separate lube oil systems:

Synthetic lube oil system for gas turbine core & intermediate pressure turbine:

Skid with 2x100% filters, 2x100% shell and tube coolers and thermostatically- controlled electric heaters.

Mineral lube oil system for generator, low pressure compressor & powerturbine:

Skid with 2x100% filters, 2x100% shell and tube coolers and thermostatically-controlled electric heaters.

Electro-hydraulic start system

An electric motor driven hydraulic pump assembly, filters, cooler and controls.

Fire protection system

Factory installed fire protection system with optical flame detection, hydrocarbon sensing and thermal detectors, piping and nozzles in the engine compartment.

24VDC battery and charger to power the fire protection system

Page 5: Budget Offer: COMPLETE TURBINE GE LMS100 Dear Sir, In ...

 

 

JERANEAS, S.L. Ronda de Atocha, 37 28012 Madrid - España T international (+34) 911 610 336 M (+34) 697 921 445 Web: www.repoweringsolutions.com Email: [email protected]

 

STRICTLY CONFIDENTIAL SUBJECT TO CONDITIONS OF NON-DISCLOSURE Proposal_economical_GE LMS100_rev101 Page 5 of 14 Date September 11, 2015

Gas Turbine Generator Control System

Freestanding GE MK VIe control panel mounted in the Power Control Module

Battery systems Battery systems mounted in the Power Control Module:

24V DC battery systems for the fire protection and gas turbine generator control systems 125V DC battery system for control cooling backup 240V DC battery system to power the mineral lube oil system DC motor driven backup

pump.

Generator Protective Relays

Microprocessor-based Beckwith M-3425 Integrated Generator Protection system module (IGPS) mounted in the turbine control panel.

“On Line” and “Off Line” Cleaning and Soak wash system

Reservoir and piping for “on-line” cleaning system and “off-line” soak cleaning system

Simple Cycle Exhaust System Exhaust stack assembly:

Expansion joint Elbow duct Stack (40 meters high) Emission ports for sample probes Four emission ports dedicated to the Environmental Protection Agency testing

requirements. Ladders and platforms All bolting hardware, gaskets and field insulation

CO Reduction System CO emissions catalyst reduction system (COR) as a part of the exhaust stack:

Expansion joint Ductwork CO oxidation catalyst

Gas Fuel Filter / Coalescing Skid

Skid consisting of duplex (2x100%) coalescing gas fuel filters

Page 6: Budget Offer: COMPLETE TURBINE GE LMS100 Dear Sir, In ...

 

 

JERANEAS, S.L. Ronda de Atocha, 37 28012 Madrid - España T international (+34) 911 610 336 M (+34) 697 921 445 Web: www.repoweringsolutions.com Email: [email protected]

 

STRICTLY CONFIDENTIAL SUBJECT TO CONDITIONS OF NON-DISCLOSURE Proposal_economical_GE LMS100_rev101 Page 6 of 14 Date September 11, 2015

Demineralized water filter skid

Skid consisting of 2x100% water filters

Continuous Emissions Monitoring System (CEMS) One CEMS system for the combustion turbine package with an extractive sampling system that provides continuous monitoring of the following parameters:

./ NOx ./ SO2 ./ CO ./ O2 ./ VOC ./ TSP ./ Temperature ./ Pressure ./ Humidity ./ Turbine exhaust flow

GTG Foundation Anchoring system

Equipment foundation anchoring systems for the combustion turbine generator package only.

GTG Motor Control Center

AC Motor Control Center for the gas turbine package motors and heaters

Power Control Module (PCM)

Prefabricated Power Control Module designed for the installation of the GTG electrical control gear

Interconnect piping

Interconnecting piping between supplied equipment

Vent piping

Vent piping for the supplied equipment

Electrical control and power interconnect cable

Interconnecting cabling between supplied equipment Cable trays, supports and accessories for the interconnecting cabling

Page 7: Budget Offer: COMPLETE TURBINE GE LMS100 Dear Sir, In ...

 

 

JERANEAS, S.L. Ronda de Atocha, 37 28012 Madrid - España T international (+34) 911 610 336 M (+34) 697 921 445 Web: www.repoweringsolutions.com Email: [email protected]

 

STRICTLY CONFIDENTIAL SUBJECT TO CONDITIONS OF NON-DISCLOSURE Proposal_economical_GE LMS100_rev101 Page 7 of 14 Date September 11, 2015

Component testing and factory test for package

The core gas turbine is performance tested at a GE Test Cell The generator is factory-tested at is factory of manufacture

Drawings, data and manuals

General Arrangement drawings Flow & Instrument diagrams Electrical on-line drawings Electrical schematic diagrams Logic diagrams O&M manuals Quality Plan and associated quality documentation applicable to the equipment supplied

and testing activities

Page 8: Budget Offer: COMPLETE TURBINE GE LMS100 Dear Sir, In ...

 

 

JERANEAS, S.L. Ronda de Atocha, 37 28012 Madrid - España T international (+34) 911 610 336 M (+34) 697 921 445 Web: www.repoweringsolutions.com Email: [email protected]

 

STRICTLY CONFIDENTIAL SUBJECT TO CONDITIONS OF NON-DISCLOSURE Proposal_economical_GE LMS100_rev101 Page 8 of 14 Date September 11, 2015

PHOTO

                           Turbine Skid   

        

Page 9: Budget Offer: COMPLETE TURBINE GE LMS100 Dear Sir, In ...

 

 

JERANEAS, S.L. Ronda de Atocha, 37 28012 Madrid - España T international (+34) 911 610 336 M (+34) 697 921 445 Web: www.repoweringsolutions.com Email: [email protected]

 

STRICTLY CONFIDENTIAL SUBJECT TO CONDITIONS OF NON-DISCLOSURE Proposal_economical_GE LMS100_rev101 Page 9 of 14 Date September 11, 2015

                            

GTG Package Equipment inside the warehouse

Page 10: Budget Offer: COMPLETE TURBINE GE LMS100 Dear Sir, In ...

 

 

JERANEAS, S.L. Ronda de Atocha, 37 28012 Madrid - España T international (+34) 911 610 336 M (+34) 697 921 445 Web: www.repoweringsolutions.com Email: [email protected]

 

STRICTLY CONFIDENTIAL SUBJECT TO CONDITIONS OF NON-DISCLOSURE Proposal_economical_GE LMS100_rev101 Page 10 of 14 Date September 11, 2015

 

 

 

 

 

 

 

 

 

         

Auxiliary Skids stored inside the

warehouse  

       

Page 11: Budget Offer: COMPLETE TURBINE GE LMS100 Dear Sir, In ...

 

 

JERANEAS, S.L. Ronda de Atocha, 37 28012 Madrid - España T international (+34) 911 610 336 M (+34) 697 921 445 Web: www.repoweringsolutions.com Email: [email protected]

 

STRICTLY CONFIDENTIAL SUBJECT TO CONDITIONS OF NON-DISCLOSURE Proposal_economical_GE LMS100_rev101 Page 11 of 14 Date September 11, 2015

 

 

Generator   

 

Outdoor storage area for the GTG Package Equipment (1)

Page 12: Budget Offer: COMPLETE TURBINE GE LMS100 Dear Sir, In ...

 

 

JERANEAS, S.L. Ronda de Atocha, 37 28012 Madrid - España T international (+34) 911 610 336 M (+34) 697 921 445 Web: www.repoweringsolutions.com Email: [email protected]

 

STRICTLY CONFIDENTIAL SUBJECT TO CONDITIONS OF NON-DISCLOSURE Proposal_economical_GE LMS100_rev101 Page 12 of 14 Date September 11, 2015

         

Outdoor storage area for the GTG

Package Equipment (2)                  

 

Outdoor storage area for the GTG Package Equipment (3)

Page 13: Budget Offer: COMPLETE TURBINE GE LMS100 Dear Sir, In ...

JERANEAS, S.L. Ronda de Atocha, 37 28012 Madrid - España T international (+34) 911 610 336 T Spain (+34) 902 103 771 M (+34) 697 921 445 Web: www.repoweringsolutions.com www.jeraneas.com Email: [email protected]

 

 STRICTLY CONFIDENTIAL SUBJECT TO CONDITIONS OF NON-DISCLOSURE Proposal_economical_GE LMS100_rev101 Page 13 of 14 Date September 11, 2015

 

 

Intercooler                         

PCM

Page 14: Budget Offer: COMPLETE TURBINE GE LMS100 Dear Sir, In ...

JERANEAS, S.L. Ronda de Atocha, 37 28012 Madrid - España T international (+34) 911 610 336 T Spain (+34) 902 103 771 M (+34) 697 921 445 Web: www.repoweringsolutions.com www.jeraneas.com Email: [email protected]

 

 STRICTLY CONFIDENTIAL SUBJECT TO CONDITIONS OF NON-DISCLOSURE Proposal_economical_GE LMS100_rev101 Page 14 of 14 Date September 11, 2015

 

. Yours sincerely JERANEAS.

Alfonso Alvaro - Commercial Director -

Page 15: Budget Offer: COMPLETE TURBINE GE LMS100 Dear Sir, In ...

LMS100®

Flexible Power

GE Energy

Page 16: Budget Offer: COMPLETE TURBINE GE LMS100 Dear Sir, In ...

GE Energy is a leading supplier of

aeroderivative gas turbines and

packaged generator sets for

industrial and marine applications.

We provide power-generating

equipment to utilities, industries

and marine fleets throughout the

world and are the world’s largest,

most experienced gas turbine

service provider.

Page 17: Budget Offer: COMPLETE TURBINE GE LMS100 Dear Sir, In ...

Defining a new era of flexible power generation, GE’s revolutionaryLMS100 provides a single, economical solution for the dispatchneeds of nearly every market condition. With unparalleled efficiency,10-minute start times, unmatched hot day performance, load fol-lowing and cycling capabilities, and reliability derived from provenarchitecture and technology, the LMS100 is the ideal solution forpower generation planners and developers.

A combination of frame and aeroderivative gas turbine technologies,this powerful machine represents the most extensive collaborationof design and manufacturing expertise in the history of GE—delivering over 100 MW with thermal efficiency in excess of 44%.

Offering superior value unavailable in other 80–160 MW gas turbines through high part-power efficiency, cycling capabilitywithout maintenance impact, dispatch reliability, turndown capability, and low emissions, the LMS100 gives dispatchers confidence they can meet customer and business needs at anytime, day or night.

A Single Solution for Your Needs

Efficiency+ Fast starts+ Hot day performance+ Load following and

cycling capabilities+ Reliability+ No maintenance penalties

= LMS100® Flexible Power

L M S 1 0 0 : F L E X I B L E P O W E R 1

Page 18: Budget Offer: COMPLETE TURBINE GE LMS100 Dear Sir, In ...

2 L M S 1 0 0 : F L E X I B L E P O W E R

The LMS100 provides unsurpassed simple-cycle efficiency and

increased power output thanks to an innovative intercooling system.

The intercooling system takes compressed airfrom the low-pressure compressor, cools it tooptimal temperatures and then redelivers it tothe high-pressure compressor. In providing anear constant stream of low temperature airto the high pressure compressor, the work ofcompression is reduced. The result is a higherpressure ratio (42:1) and increased mass flow(460 lb/sec).

In simple-cycle applications, the LMS100 canachieve thermal efficiency in excess of 44%.That’s nearly a 10 point improvement overevery turbine in its size range. The impressivelevel of efficiency—when combined with theability to cycle without maintenance intervalimpact—may translate into $4-7 MM in NetPresent Value Savings over 15 years.*

Our Foundation for Flexibility

Model ISO BaseRating (kW)

Heat Rate(Btu/kWh) Efficiency% Mass Flow

(lb/sec)Turbine

Speed (RPM)ExhaustTemp (F) Comments

LMS100PB 97,718 7,592 45.0% 453 3,600 783 DLE, 25 ppm NOx

LMS100PB 97,878 7,579 45.0% 453 3,000 784 DLE, 25 ppm NOx

LMS100PA 103,112 7773 43.9% 469 3,600 770 water injected to 25 ppm NOx

LMS100PA 103,162 7769 43.9% 469 3,000 767 water injected to 25 ppm NOx

LMS100 ISO Performance Data

Conditions: Performance at the generator terminals; NOx = 25 ppm or 50 mg/Nm3; 59F or 15C, 60% Relative Humidity; No Losses; Fuel Spec. Gas (LHV= 19,000 BTU/lb)

* 5¢/mmBtu gas

Page 19: Budget Offer: COMPLETE TURBINE GE LMS100 Dear Sir, In ...

L M S 1 0 0 : F L E X I B L E P O W E R 3

As the only company with the necessary technology base and product experience to bring

this innovative product to the power generation industry, GE has incorporated extensive

customer feedback into the LMS100 development program—ensuring it has the flexibility

to meet current and future needs. The resulting breakthrough system delivers 100 MW

of power with:

Features of Flexibility

0

1000

2000

3000

4000

5000

6000

7000

8000

9000

10000

Spee

d, R

PM

0

10

20

30

40

50

60

70

80

90

100

Pow

er, M

W

10 Minutes

Core Speed

Power Turbine Speed

Power

Dry motor/Purge

Ignition

Synch idle

Accelerate to synch idle

Accelerate to power

110000

105000

100000

95000

90000

85000

80000

75000

700000 20 40 60

Temperature (°F)

80 100 120

Pow

er (k

W)

LMS 100 Nat. Gas WaterOther Industrial GT

25.0%

30.0%

35.0%

40.0%

45.0%

50.0%

50.0% 60.0% 70.0% 80.0% 90.0% 100.0%

LHV

Effic

ienc

y,%

LMS100Conv. GT

Power Level

10-minute fast starts with cycling capabilityThe flexibility of aircraft engine technology—with 10-minute startsfrom cold iron to full power—and the ability to start and stop in short15 minute cycles (several times per day, if needed) without impactingmaintenance intervals.

Improved load following and part load efficiencyThe flexibility to provide 50 MW of power in less than one minute. Whenoperating at 50% power, the LMS100 can ramp to full power in lessthan 60 seconds, providing fast response to load demand variations.

The flexibility to provide power at part load as efficiently as most gasturbines at full load—enabling efficient operation anywhere between 50 and 100 MW, as demand requires. At 50% load, the LMS100 candeliver power at 40% simple-cycle efficiency.

The flexibility to provide grid support without load reduction. Even withup to 5% grid frequency variation, the LMS100 can operate with verylittle power loss—making it uniquely capable of supporting the grid intimes of high demand and load fluctuations.

Incredible hot day performanceThe flexibility to sustain power levels on hot days when demand isgreatest . The LMS100 will increase in power as the temperaturerises—up to 75°F (~24°C)—and then fall off in power at a much slowerrate than conventional gas turbines. When the temperature againincreases demand on the grid, the LMS100 will be at the top of thelist to dispatch

Page 20: Budget Offer: COMPLETE TURBINE GE LMS100 Dear Sir, In ...

4 L M S 1 0 0 : F L E X I B L E P O W E R

Better efficiency also means less fuel burned per megawatt generated and less CO2 emissions.

The efficiency advantage of the LMS100 offers potential savings in terms of CO2 taxes through

reduced greenhouse gas emissions of as much as $0.6 MM each year when compared to a typical

simple-cycle gas turbine plant.

Based on an average peaking season of 2,184 hours, the LMS100 reduces CO2 emissionsby more than 30,000 tons when compared to a typical simple-cycle 100 MW gas turbineplant. This CO2 reduction is equal to the amount of carbon dioxide absorbed byapproximately 7,400 acres of forest.

Efficient Performance

Ecomagination is GE's commitment to aggressively

bring to market new technologies that will help

customers meet pressing environmental challenges.

Ecomagination technologies offer improved efficiency,

lower emissions and/or improved operating

performance compared to other similar power

generation technologies in the same power class.

The LMS100, as one of the newest products in the

ecomagination portfolio offers our customers 100

MW at 46% thermal efficiency with a wide range of

operating flexibility for peaking, mid-range and

base-load operation with lower start up emissions

and 10-minute starts.

Page 21: Budget Offer: COMPLETE TURBINE GE LMS100 Dear Sir, In ...

L M S 1 0 0 : F L E X I B L E P O W E R 5

Sound heritageThe LMS100 core engine is derived from the CF6 family of aircraft engines, the same baselinearchitecture as the LM6000®. The current LM6000 fleet includes 588 operating engines withover 10.5 million accumulated fired hours of operation. Reliability for the LM6000 fleet iscurrently 99.14% and availability is currently 97.76%. The low-pressure compressor (LPC)is derived from GE’s MS6001FA gas turbine which has 65 units in operation with morethan 1,000,000 hours of operation.

*Based on ORAP® reliability data, using current sample, which includes 151 operating units.ORAP®; All rights reserved: SPS®

Customer-designed controlsThe LMS100 control system employs the Mark VIe and fiber optics for signal transmissionbetween the package and control system. This system reduces the number of signalinterconnects by 90% and the number of mechanical interconnects by 25%—which yieldsa simpler and more reliable design with a faster, more efficient installation and startup.

Designed for reliabilityIn addition, the integrated control system includes redundant sensors with smart selectionlogic to reduce single sensor failure trips. The fiberoptic distributed I/O (input/output) systemis located outside the module to prevent electromagnetic or radio frequency interferenceand minimize false trips. Reliability of the LMS100 is further enhanced by redundant fans,fuel pumps, resistance temperature detectors (RTDs) and remote monitoring and diagnostics.

Comprehensive full scale validation testsConsistent with GE’s practice for design validation, extensive design assurance and validationtests were established and executed for both the engine and balance of plant equipment.

The core engine, a gas generator consisting of the LMS100 high-pressure compressor, singleannular combustor and high-pressure turbine, completed testing in December 2004 atthe high altitude test cell in GE’s aircraft engine facility in Ohio. More than 1500 pieces ofinstrumentation were used to measure key design parameters. The testing confirmedaeromechanics, mechanical design and variable geometry optimization for performance,paving the way for full scale power plant validation testing.

Extensive, full scale testing of an LMS100 simple-cycle power plant was conducted at GE’spackaging facility in Houston, Texas. More than 2,500 pieces of instrumentation were usedto validate performance, emissions, intercooler operation and sub-system capability at themost extreme operating conditions expected in commercial service.

The LMS100 full load power plant test, completed in November 2005, confirmed performance,operability, emissions, mechanical and electrical operations all successfully met orexceeded the requirements. Testing demonstrated 10-minute starts, fast load following,transient capability and efficiency—all hallmark characteristics of the LMS100.

Proven, Reliable Technology

Page 22: Budget Offer: COMPLETE TURBINE GE LMS100 Dear Sir, In ...

6 L M S 1 0 0 : F L E X I B L E P O W E R

Designed for Availability and MainMaintainability features● Modular construction permits replacement of the aero components without total disassembly

● Multiple borescope ports allow on-condition monitoring without turbine disassembly

● Condition-based maintenance and remote diagnostics

● Split casing construction of the booster (LPC) and aeroderivative compressor allows detailed on-site inspection and blade replacement

● Package accessory systems are externally mounted for ease of on-site replacement

● Package mounted maintenance cranes in auxiliary module

Modular “supercore” enhances power plant availabilityGE has established a target availability of 97.5% and 98.5% target reliability for a mature LMS100 power plant. The “supercore” consistsof the HPC, Combustor, HPT and IPT rotable modules, which can be exchanged in less than four days during on-site maintenance tooptimize plant availability.

F R O N T F R A M E

H I G H P R E S S U R EC O M P R E S S O R

( H P C ) C O M B U S T O R

H I G H P R E S S U R E T U R B I N E

( H P T )

I N T E R M E D I AT E P R E S S U R E T U R B I N E

( I P T )T U R B I N E

M I D F R A M E

2 4 H O U R B R E A K E R - T O - B R E A K E RC H A N G E O U T O F T H E S U P E R C O R E

Page 23: Budget Offer: COMPLETE TURBINE GE LMS100 Dear Sir, In ...

LMS100 service intervals

Maintenance servicesAll warranty and follow-on services for the LMS100 will be provided by GE Energy either on site or at one of several service centerlocations around the world. These services can include Contractual Service Agreements (CSAs), lease engines, spare parts, rotable modules,training resources and user conferences.

GE Energy’s Contractual Services Agreements provide the field service, labor, parts and repairs necessary for equipment maintenancewhile protecting your investment and minimizing your costs. CSA programs can be structured to include unplanned maintenance eventswith guarantee incentives on reliability and availability.

GE’s lease engine program provides a spare “supercore” that can be installed in 24 hours when service center maintenance is required.The power turbine module can also be replaced within an additional 24 hours.

L M S 1 0 0 : F L E X I B L E P O W E R 7

tainability

Interval Scheduled Maintenance Action Outage Duration4,000 hours (every 4K h) Borescope inspection (includes cool-down time) 12 hours

25,000 hours

50,000 hours

75,000 hours

Depot maintenance(b)

1) Major hot section overhaul (combustor, HPT, IPT)2) Inspect booster, intercooler, scroll frames, HPC, aft shaft and bearings(c)

3) Power turbine overhaul

Hot section interval(b)

1) On-site hot section replacement (combustor, HPT, IPT)

Hot section interval*1) On-site hot section replacement (combustor, HPT, IPT)

4 days(a)

4 days(a)

4 days(a)

100,000 hours Depot maintenance(b)

1) Major hot section overhaul (combustor, HPT, IPT)2) Inspect booster, intercooler, scroll frames, HPC, aft shaft and bearings(c)

3) Power turbine overhaul

4 days(a)

(a) Rotable module installed during maintenance period.(b) Lease/spare “supercore” and Power Turbine modules are installed during maintenance period. For depot maintenance, outage duration is 60 days if no spare/lease module(s) are used.(c) Roller and ball bearings are replaced at 50,000 hours; hydrodynamic bearings are inspected.

Page 24: Budget Offer: COMPLETE TURBINE GE LMS100 Dear Sir, In ...

The LMS100 is a flexible growth platform designed to meet your changing energy

needs. While actual plant layout depends on specific customer needs and site

requirements, there are four basic LMS100 configurations available when combined

with intercooler selection and combustion technology.

• LMS100 Single Annular Combustor with Water – Water or steam can beinjected into the combustor to provide emission reduction and achieve25 ppm NOX levels while operating on natural gas fuels between 50%

and 100% power.

• LMS100 DLE – An advanced dry low emission (DLE) combustor will beavailable for sites that have a restriction on water usage. Using the DLEcombustor, customers will be able to achieve 25 ppm for both NOX and

CO emissions while operating on natural gas fuels.

• Intercooler Options – Water is the primary cooling agent in the shell and tube heat exchanger available with the LMS100. In areas withan abundant water supply, a standard evaporative cooling tower can be integrated. An optional closed-loop wet intercooler can be providedwith a secondary dry, fin-fan cooler if water usage is restricted.

Applications• Feed Water Applications—Increased efficiency, improved flexibility and better economics are among the potential benefits of integrating

the LMS100 gas turbine for feed water heating in a coal fired steam plant. The improved efficiency and increased output are achievedthrough minor modifications of the steam cycle to reduce or eliminate steam extractions in lieu of the gas turbine exhaust andintercooler to heat the feed water.

• Wind Farm Integration – The operating characteristics of the LMS100 make it an ideal solution for firming variable wind power. Alternativepower sources require high maneuverability, high efficiency (even at partial load), fast starting, low initial capital costs (consistent withmoderate to low capacity factors) and good environmental characteristics. The LMS100 simple-cycle gas turbine has all of thesecharacteristics, making a high performance hybrid wind-GT system now economically possible.

Flexible Growth Platform

8 L M S 1 0 0 : F L E X I B L E P O W E R

Gas, Liquid or Dual Fuel

Single Annular(SAC)

25 ppmNoneNoneDLE2GasLMS100 DLE, 50/60 Hz

25 ppmNoneWaterLMS100 SAC, 50/60 Hz

NOx LevelPowerAugmentation

DiluentCombustorFuelProductOfferings

LMS100 System Configurations

Four basic LMS100 configurations are available as this proudct is introduced. When combined with intercooler selection and duty applications, the LMS100 offers 20 different configuration choices.

Page 25: Budget Offer: COMPLETE TURBINE GE LMS100 Dear Sir, In ...
Page 26: Budget Offer: COMPLETE TURBINE GE LMS100 Dear Sir, In ...

GE Energy1333 West Loop SouthHouston, Texas 77027713.803.0900www.ge-energy.com/lms100

For more information on the LMS100gas turbine system, contact your GE Energyrepresentative or email us at [email protected].

©2006 General Electric Company. All Rights Reserved.

GEA-14355 A (09/06)