BSC PreventiveMantenance Update Jan2012
description
Transcript of BSC PreventiveMantenance Update Jan2012
-
Document number:
VN-RP-ENG-2004-011
Title: BSC&XCDR Preventive Maintenance Service Record Revision:
Release Date:
V02
07-Jan-2004
BSC_PreventiveMantenance_update_Jan2012.doc Page 1 / 17
BSC Hardware
Preventive Maintenance
Service Record
SITE NAME
REGION
CABINET
CONFIGURATION
Motorola Engineer
Motorola Signature
VNP Engineer
VNP Signature
DATE
-
Document number:
VN-RP-ENG-2004-011
Title: BSC&XCDR Preventive Maintenance Service Record Revision:
Release Date:
V02
07-Jan-2004
BSC_PreventiveMantenance_update_Jan2012.doc Page 2 / 17
A. BSS System Health Check
1. Cabinet view
2. General Configuration Cage Connection Type: Expansion Extension
Clock Synchronization Status: Phase locked Free run
GPRS Service: Available Unavailable
External Alarm System: Available Unavailable
Non Volatile Memory (NVM) Available Unavailable
-
Document number:
VN-RP-ENG-2004-011
Title: BSC&XCDR Preventive Maintenance Service Record Revision:
Release Date:
V02
07-Jan-2004
BSC_PreventiveMantenance_update_Jan2012.doc Page 3 / 17
3. Configuration and Link Diagram i. Hardware Configuration
Items Total Items Total
CAB GCLK
CAGE BSP GPROC
MSI CSFP GPROC
GDP OMF GPROC
XCDR LCF GPROC
KSW Pool GPROC
ii. Connection Configuration Connected to MSC:
Connected to RXCDR: The number of sites:
MMS
Port
Connected To
Network Entity
At Port Carried
MMS 0 0 TRAU_XXXM MMS 6 0 MTL-x, OML-x, XBL-x, OPL-x,, CIC:xxx-yyy,
MMS 0 1 BTS_N:XXX-YYY MMS 0 0 RSL-x, RTF channel
MMS 1 0
MMS 1 1
-
Document number:
VN-RP-ENG-2004-011
Title: BSC&XCDR Preventive Maintenance Service Record Revision:
Release Date:
V02
07-Jan-2004
BSC_PreventiveMantenance_update_Jan2012.doc Page 4 / 17
4. Event and alarm summary
5. Comments/Remarks
Any device with active alarms? Any device with repeated alarms? BSS software code object list in NVM and BSP are identical? Any redundancy lack: BSP, Pool GPROC?
-
Document number:
VN-RP-ENG-2004-011
Title: BSC&XCDR Preventive Maintenance Service Record Revision:
Release Date:
V02
07-Jan-2004
BSC_PreventiveMantenance_update_Jan2012.doc Page 5 / 17
B. Hardware Checking
1. BSSC CABINET CHECK
D.C Voltage Tests D.C. Power Supply Tests for cabinets (Requirement DC input 53.65 to 55.40 Volts)
DC input to First cabinet DC input to Second cabinet DC input to Third cabinet
Volts
Volts Volts
Digital Shelf IPSM Insert dummy load card into slot 18 and test each IPSM with only one IPSM powered up at a time. Record results.
Upper shelf in the first cabinet
Voltage IPSM 0 IPSM 1 IPSM 2 Limits
+ 12 volts +/- 600mvdc
- 12 volts +/- 600mvdc
+ 5 volts +/- 100mvdc
Lower shelf in the first cabinet
Voltage IPSM 0 IPSM 1 IPSM 2 Limits
+ 12 volts +/- 600mvdc
- 12 volts +/- 600mvdc
+ 5 volts +/- 100mvdc
Upper shelf in the second cabinet
Voltage IPSM 0 IPSM 1 IPSM 2 Limits
+ 12 volts +/- 600mvdc
- 12 volts +/- 600mvdc
+ 5 volts +/- 100mvdc
Lower shelf in the second cabinet
Voltage IPSM 0 IPSM 1 IPSM 2 Limits
+ 12 volts +/- 600mvdc
- 12 volts +/- 600mvdc
+ 5 volts +/- 100mvdc
Comment and Action Done:
-
Document number:
VN-RP-ENG-2004-011
Title: BSC&XCDR Preventive Maintenance Service Record Revision:
Release Date:
V02
07-Jan-2004
BSC_PreventiveMantenance_update_Jan2012.doc Page 6 / 17
2. CIRCUIT BREAKER ALARM TEST
Circuit breaker CB 0 CB 1 CB 2 CB 3 CB 4 CB 5 CB 6 CB 7 CB 8 CB 9
First Cabinet
Second Cabinet
Third Cabinet
Switch off each circuit breaker in turn and check alarms register on laptop indicate Pass or Fail in box.
Comment and Action Done:
3. EAS (FIX) ALARMS TESTS Purpose: 1. External alarm was installed and connected to this BSC? 2. Verify the functionality of all external alarms, which have been defined by Motorola on site. 3. Ensure the alarms are being reported to the OMCR 4. Motorola will only check those EAS alarms installed by Motorola.
Alarms E.A.S.
Optocoupler 1
Optocoupler 2
Optocoupler 3
Optocoupler 4
Optocoupler 5
Optocoupler 6
Optocoupler 7
Optocoupler 8
Comment and Action Done:
-
Document number:
VN-RP-ENG-2004-011
Title: BSC&XCDR Preventive Maintenance Service Record Revision:
Release Date:
V02
07-Jan-2004
BSC_PreventiveMantenance_update_Jan2012.doc Page 7 / 17
4. SITE CHECK
Tasks Status
Check the distribution frame (DDF) wiring description table available and attached to DDF frame?
Check all MMS ports at DDF frame are labeled?
Check all BIB and power connections are securely fastened.
Perform air filter cleaning
Perform GCLK calibration
SLOT SERIAL
NUMBER OF GCLK BOARD
DATE
DATE OF LAST
CALIBRATION
FREQUENCY BEFORE
CALIBRATION
Comment and Action Done:
-
Document number:
VN-RP-ENG-2004-011
Title: BSC&XCDR Preventive Maintenance Service Record Revision:
Release Date:
V02
07-Jan-2004
BSC_PreventiveMantenance_update_Jan2012.doc Page 8 / 17
5. CABLING/WIRING/MISC CHECK
Tasks Status
Having any cabling within the cabinets for loose/bad connections, signs of wear or rodent damage?
Having any ground wire connections at rack for tightness and signs of corrosion?
Having any check of DC power connections at rack for tightness and signs of corrosion?
Having any missing/loose screws on equipment racks?
Current BSC/RXCDR configuration matches with database configuration?
Having labeling for all Cabinets, DC cables, grounding cables, BIB cables, Alarm cable and Battery cables? Labeling cables at 2 ends and clearly?
Having label for DC circuit breaker to single cabinets?
All labels have the rule and follow with VNP or Motorola standard?
Comment and Action Done:
-
Document number:
VN-RP-ENG-2004-011
Title: BSC&XCDR Preventive Maintenance Service Record Revision:
Release Date:
V02
07-Jan-2004
BSC_PreventiveMantenance_update_Jan2012.doc Page 9 / 17
6. EXTERIOR GROUND SYSTEM CHECK 1. If applicable, clean debris from inspection holes. Report broken or missing inspection hole covers. 2. Inspect the following grounding connections and notify customer of any action required. (Not tightness or signs of corrosion)
Comment and Action Done:
7. AIR CONDITIONING CHECK
Using digital thermometer to measure equipment room temperature, it should be not excessive 26 degree Celsius.
Comment and Action Done:
8. BATTERY SYSTEM CHECK Using Battery tester makes sure all cells of battery system having good inter-cell resistance and cell impedance as well. Note down any issue with battery system?
Comment and Action Done:
9. PICTURES
1. Equipment Room 2. BSSC cabinets and cages 3. Any installation abnormal
For the purpose of recording and filling, these pictures are printed and attached to section D
-
Document number:
VN-RP-ENG-2004-011
Title: BSC&XCDR Preventive Maintenance Service Record Revision:
Release Date:
V02
07-Jan-2004
BSC_PreventiveMantenance_update_Jan2012.doc Page 10 / 17
10. UPDATE INVENTORY OF BSC/RXCDR CABINET CAGE 0
CARDS BOARD POSITION PART NUMBER SERIAL NUMBER
CAGE
BTC SLOT 0
KSW SLOT 1
GCLK SLOT 2
GCLK SLOT 4
MSI/GDP SLOT 6
MSI/GDP SLOT 7
MSI/GDP SLOT 8
MSI/GDP SLOT 9
MSI/GDP SLOT 10
MSI/GDP SLOT 11
MSI/GDP SLOT 12
MSI/GDP SLOT 13
MSI/GDP SLOT 14
MSI/GDP SLOT 15
MSI/GDP SLOT 16
MSI/GDP SLOT 17
GPROC-2/GDP SLOT 18
GPROC-2/GDP SLOT 19
GPROC-2/GDP SLOT 20
GPROC-2/GDP SLOT 21
GPROC-2/GDP SLOT 22
GPROC-2/GDP SLOT 23
GPROC-2 SLOT 24
GPROC-2 SLOT 25
GPROC-2/NVRAM SLOT 26
KSW SLOT 27
BTC SLOT 28
IPSM SLOT 0
IPSM SLOT 1
IPSM SLOT 2
CAGE 1
CARDS BOARD POSITION PART NUMBER SERIAL NUMBER
CAGE
BTC SLOT 0
KSW SLOT 1
GCLK SLOT 2
GCLK SLOT 4
MSI/GDP SLOT 6
MSI/GDP SLOT 7
MSI/GDP SLOT 8
MSI/GDP SLOT 9
MSI/GDP SLOT 10
MSI/GDP SLOT 11
MSI/GDP SLOT 12
-
Document number:
VN-RP-ENG-2004-011
Title: BSC&XCDR Preventive Maintenance Service Record Revision:
Release Date:
V02
07-Jan-2004
BSC_PreventiveMantenance_update_Jan2012.doc Page 11 / 17
MSI/GDP SLOT 13
MSI/GDP SLOT 14
MSI/GDP SLOT 15
MSI/GDP SLOT 16
MSI/GDP SLOT 17
GPROC-2/GDP SLOT 18
GPROC-2/GDP SLOT 19
GPROC-2/GDP SLOT 20
GPROC-2/GDP SLOT 21
GPROC-2/GDP SLOT 22
GPROC-2/GDP SLOT 23
GPROC-2 SLOT 24
GPROC-2 SLOT 25
GPROC-2/NVRAM SLOT 26
KSW SLOT 27
BTC SLOT 28
IPSM SLOT 0
IPSM SLOT 1
IPSM SLOT 2
CAGE 2
CARDS BOARD POSITION PART NUMBER SERIAL NUMBER
CAGE
BTC SLOT 0
KSW SLOT 1
GCLK SLOT 2
GCLK SLOT 4
MSI/GDP SLOT 6
MSI/GDP SLOT 7
MSI/GDP SLOT 8
MSI/GDP SLOT 9
MSI/GDP SLOT 10
MSI/GDP SLOT 11
MSI/GDP SLOT 12
MSI/GDP SLOT 13
MSI/GDP SLOT 14
MSI/GDP SLOT 15
MSI/GDP SLOT 16
MSI/GDP SLOT 17
GPROC-2/GDP SLOT 18
GPROC-2/GDP SLOT 19
GPROC-2/GDP SLOT 20
GPROC-2/GDP SLOT 21
GPROC-2/GDP SLOT 22
GPROC-2/GDP SLOT 23
GPROC-2 SLOT 24
GPROC-2 SLOT 25
GPROC-2/NVRAM SLOT 26
KSW SLOT 27
-
Document number:
VN-RP-ENG-2004-011
Title: BSC&XCDR Preventive Maintenance Service Record Revision:
Release Date:
V02
07-Jan-2004
BSC_PreventiveMantenance_update_Jan2012.doc Page 12 / 17
BTC SLOT 28
IPSM SLOT 0
IPSM SLOT 1
IPSM SLOT 2
-
Document number:
VN-RP-ENG-2004-011
Title: BSC&XCDR Preventive Maintenance Service Record Revision:
Release Date:
V02
07-Jan-2004
BSC_PreventiveMantenance_update_Jan2012.doc Page 13 / 17
11. RECTIFIER MODULE TEST AND COMMISSIONING RESULTS
The first module
Date
Module Type
S/N
No. Item Verified Values Specification Pass Fail Remarks
1 AC Input 198 to 242V
2 Grounding
-
Document number:
VN-RP-ENG-2004-011
Title: BSC&XCDR Preventive Maintenance Service Record Revision:
Release Date:
V02
07-Jan-2004
BSC_PreventiveMantenance_update_Jan2012.doc Page 14 / 17
The fourth module
Date
Module Type
S/N
No. Item Verified Values Specification Pass Fail Remarks
1 AC Input 198 to 242V
2 Grounding
-
Document number:
VN-RP-ENG-2004-011
Title: BSC&XCDR Preventive Maintenance Service Record Revision:
Release Date:
V02
07-Jan-2004
BSC_PreventiveMantenance_update_Jan2012.doc Page 15 / 17
12. POWER BOARD TEST AND COMMISSIONING RESULTS.
Power Type
S/N
No. Item Verified Values Specification Pass Fail Remarks
1 LED Display Checking the
operation of LED
2 Major Alarm
(Mains Fails)
LED Indicated
Alarm activated
3 Minor Alarm
(Rec Fails)
LED Indicated
Alarm activated
4 HV Alarm 58.40 V
5 LV Alarm 48.25 V
-
Document number:
VN-RP-ENG-2004-011
Title: BSC&XCDR Preventive Maintenance Service Record Revision:
Release Date:
V02
07-Jan-2004
BSC_PreventiveMantenance_update_Jan2012.doc Page 16 / 17
C. Findings/Outstanding Issues
-
Document number:
VN-RP-ENG-2004-011
Title: BSC&XCDR Preventive Maintenance Service Record Revision:
Release Date:
V02
07-Jan-2004
BSC_PreventiveMantenance_update_Jan2012.doc Page 17 / 17
D. Equipment and Installation Pictures