BS241 Commissioning
-
Upload
alexander-villa-ferraro -
Category
Documents
-
view
763 -
download
17
Transcript of BS241 Commissioning
![Page 1: BS241 Commissioning](https://reader034.fdocuments.net/reader034/viewer/2022050712/5513a5364a7959f1028b4d1d/html5/thumbnails/1.jpg)
BS 241 Commissioning
![Page 2: BS241 Commissioning](https://reader034.fdocuments.net/reader034/viewer/2022050712/5513a5364a7959f1028b4d1d/html5/thumbnails/2.jpg)
Visual Check
CBC
TRL
© Siemens, 2005Page 2D
C
![Page 3: BS241 Commissioning](https://reader034.fdocuments.net/reader034/viewer/2022050712/5513a5364a7959f1028b4d1d/html5/thumbnails/3.jpg)
Visual CheckCOBA and COSA Jumper Setting
© Siemens, 2005Page 3
![Page 4: BS241 Commissioning](https://reader034.fdocuments.net/reader034/viewer/2022050712/5513a5364a7959f1028b4d1d/html5/thumbnails/4.jpg)
Visual CheckACT DIP Switch Setting
4
Rack TypeBase Rack
Rack No0
Switch 1 Switch 2 Switch 3 Switch 4off off off on
ON 1 2
3 Base Rack
Extension RackExtension RackService RackService Rack
01234
offonoffonoff
offoffononoff
offoffoffoffon
ononononon
Service Rack 5 on off on on ACT factory setting
© Siemens, 2005Page 4
Service Rack 6 off on on onService Rack 7 on on on on
![Page 5: BS241 Commissioning](https://reader034.fdocuments.net/reader034/viewer/2022050712/5513a5364a7959f1028b4d1d/html5/thumbnails/5.jpg)
Visual CheckSemirigid Wiring
© Siemens, 2005Page 5
![Page 6: BS241 Commissioning](https://reader034.fdocuments.net/reader034/viewer/2022050712/5513a5364a7959f1028b4d1d/html5/thumbnails/6.jpg)
Visual CheckCAN - BUS
CAN OUT
Serial IF
- 48CAN OUT CAN IN CAN OUT CAN IN
CAN TEST LPA
Serial IF
CAN TEST LPA CAN TEST LPA
Service 2/2 Service 2/1 Service 1 Base Extension 1 Extension 2
© Siemens, 2005Page 6
![Page 7: BS241 Commissioning](https://reader034.fdocuments.net/reader034/viewer/2022050712/5513a5364a7959f1028b4d1d/html5/thumbnails/7.jpg)
Visual CheckPCM Link
KRONE LSA DDF
910 11
12
TX RX TX RXA A A AB B B BG
ND
GN
D
GN
D
GN
D
12 3
4
56
78
91 2 3 4
TX RX TX RXA A A AB B B BG
ND
GN
D
GN
D
GN
D
5 6 7 8 9 10 11 12
TX RX TX RX
© Siemens, 2005Page 7
![Page 8: BS241 Commissioning](https://reader034.fdocuments.net/reader034/viewer/2022050712/5513a5364a7959f1028b4d1d/html5/thumbnails/8.jpg)
Commissioning Flow
TEI = ?Timeslot = ?
SALUNAME = ?BTSM = ? Set Rack -> 0 Create Rack 3
Create ACDCPno
Base Rack Service Rack
data complete ??
Start Commissioning
Create ACT
Create COSA
Create ACT
Create ACDCP
Create Batteryyes
Start Commissioning
Turn on BTS
Create COSA
Create BPORT
Create LAPDLE
Check phase
Format BTSE Flash
Set BTSM
Set BTSEP
Create FANP Create FANP
phas
e 2
phase 1
Download SW
Activate SW
Create CU
Create DULNA
Create DUVSWRlogin (phase 2)
login (phase 3)
UnlockRequest BTSM
Remote to BSC
channel
© Siemens, 2005Page 8
Create ENVABTSE
CONNBSC BTSM
login (phase 2) channel
TRX
BTS
unlock
![Page 9: BS241 Commissioning](https://reader034.fdocuments.net/reader034/viewer/2022050712/5513a5364a7959f1028b4d1d/html5/thumbnails/9.jpg)
ConfigurationPCMB, BTSM and Mapping Timeslot in Abis Interface
© Siemens, 2005Page 9
![Page 10: BS241 Commissioning](https://reader034.fdocuments.net/reader034/viewer/2022050712/5513a5364a7959f1028b4d1d/html5/thumbnails/10.jpg)
ConfigurationLink Connection
PCM 1PCM 2PCM 3PCM 4
PCM 1PCM 2PCM 3PCM 4
NodeBPORT
1 20 3QTLP
1 2 3 4
BSC
NodeBTS A
QTLP
Link Configuration :BTS A and BTS C -> Star
PCM
1PC
M 2
PCM
3PC
M 4
PCM 1PCM 2PCM 3PCM 4
BTS A and BTS C > StarBTS B -> multidrop from BTS A
BPORT
BTS B
1 20 3BPORT
BTS C
1 20 3
© Siemens, 2005Page 10
![Page 11: BS241 Commissioning](https://reader034.fdocuments.net/reader034/viewer/2022050712/5513a5364a7959f1028b4d1d/html5/thumbnails/11.jpg)
Commissioning FlowFormat COBA
© Siemens, 2005Page 11
![Page 12: BS241 Commissioning](https://reader034.fdocuments.net/reader034/viewer/2022050712/5513a5364a7959f1028b4d1d/html5/thumbnails/12.jpg)
Commissioning FlowDownload Software
© Siemens, 2005Page 12
![Page 13: BS241 Commissioning](https://reader034.fdocuments.net/reader034/viewer/2022050712/5513a5364a7959f1028b4d1d/html5/thumbnails/13.jpg)
Commissioning FlowActivate Software
© Siemens, 2005Page 13
![Page 14: BS241 Commissioning](https://reader034.fdocuments.net/reader034/viewer/2022050712/5513a5364a7959f1028b4d1d/html5/thumbnails/14.jpg)
Commissioning FlowSet Rack
© Siemens, 2005Page 14
![Page 15: BS241 Commissioning](https://reader034.fdocuments.net/reader034/viewer/2022050712/5513a5364a7959f1028b4d1d/html5/thumbnails/15.jpg)
Commissioning FlowCreate ACT
© Siemens, 2005Page 15
![Page 16: BS241 Commissioning](https://reader034.fdocuments.net/reader034/viewer/2022050712/5513a5364a7959f1028b4d1d/html5/thumbnails/16.jpg)
Commissioning FlowCreate COSA
© Siemens, 2005Page 16
![Page 17: BS241 Commissioning](https://reader034.fdocuments.net/reader034/viewer/2022050712/5513a5364a7959f1028b4d1d/html5/thumbnails/17.jpg)
Commissioning FlowCreate BPORT
© Siemens, 2005Page 17
![Page 18: BS241 Commissioning](https://reader034.fdocuments.net/reader034/viewer/2022050712/5513a5364a7959f1028b4d1d/html5/thumbnails/18.jpg)
Commissioning FlowCreate LAPDLE
© Siemens, 2005Page 18
![Page 19: BS241 Commissioning](https://reader034.fdocuments.net/reader034/viewer/2022050712/5513a5364a7959f1028b4d1d/html5/thumbnails/19.jpg)
Commissioning FlowSet BTSM
© Siemens, 2005Page 19
![Page 20: BS241 Commissioning](https://reader034.fdocuments.net/reader034/viewer/2022050712/5513a5364a7959f1028b4d1d/html5/thumbnails/20.jpg)
Commissioning FlowSet BTSEP
© Siemens, 2005Page 20
![Page 21: BS241 Commissioning](https://reader034.fdocuments.net/reader034/viewer/2022050712/5513a5364a7959f1028b4d1d/html5/thumbnails/21.jpg)
Commissioning FlowCreate FANP
© Siemens, 2005Page 21
![Page 22: BS241 Commissioning](https://reader034.fdocuments.net/reader034/viewer/2022050712/5513a5364a7959f1028b4d1d/html5/thumbnails/22.jpg)
Commissioning FlowCreate CU
© Siemens, 2005Page 22
![Page 23: BS241 Commissioning](https://reader034.fdocuments.net/reader034/viewer/2022050712/5513a5364a7959f1028b4d1d/html5/thumbnails/23.jpg)
Commissioning FlowCreate DULNA
Continue to next DULNA
© Siemens, 2005Page 23
![Page 24: BS241 Commissioning](https://reader034.fdocuments.net/reader034/viewer/2022050712/5513a5364a7959f1028b4d1d/html5/thumbnails/24.jpg)
Commissioning FlowCreate DUVSWR
Continue to next DUVSWR
© Siemens, 2005Page 24
![Page 25: BS241 Commissioning](https://reader034.fdocuments.net/reader034/viewer/2022050712/5513a5364a7959f1028b4d1d/html5/thumbnails/25.jpg)
Commissioning FlowCreate ENVABTSE
© Siemens, 2005Page 25
![Page 26: BS241 Commissioning](https://reader034.fdocuments.net/reader034/viewer/2022050712/5513a5364a7959f1028b4d1d/html5/thumbnails/26.jpg)
Commissioning FlowSwitch Phase from 2 to 3
© Siemens, 2005Page 26
![Page 27: BS241 Commissioning](https://reader034.fdocuments.net/reader034/viewer/2022050712/5513a5364a7959f1028b4d1d/html5/thumbnails/27.jpg)
Commissioning FlowUnlock BTSM
© Siemens, 2005Page 27
![Page 28: BS241 Commissioning](https://reader034.fdocuments.net/reader034/viewer/2022050712/5513a5364a7959f1028b4d1d/html5/thumbnails/28.jpg)
Commissioning FlowUnlock Channel (Remote from BSC)
© Siemens, 2005Page 28
![Page 29: BS241 Commissioning](https://reader034.fdocuments.net/reader034/viewer/2022050712/5513a5364a7959f1028b4d1d/html5/thumbnails/29.jpg)
Commissioning FlowUnlock TRX (Remote from BSC)
© Siemens, 2005Page 29
![Page 30: BS241 Commissioning](https://reader034.fdocuments.net/reader034/viewer/2022050712/5513a5364a7959f1028b4d1d/html5/thumbnails/30.jpg)
Commissioning FlowUnlock BTS (Remote from BSC)
© Siemens, 2005Page 30
![Page 31: BS241 Commissioning](https://reader034.fdocuments.net/reader034/viewer/2022050712/5513a5364a7959f1028b4d1d/html5/thumbnails/31.jpg)
Commissioning FlowUnlock PTPPKF (Remote from BSC)
Only for BTS that support GPRS
© Siemens, 2005Page 31
![Page 32: BS241 Commissioning](https://reader034.fdocuments.net/reader034/viewer/2022050712/5513a5364a7959f1028b4d1d/html5/thumbnails/32.jpg)
Data Inventory
Inventory data on RackAvailable ?
1
Upload REMINV2
no yes
Upload REMINV2
Open file taken from (1), ex :OMP_S5001458_NE374RM2407.IDF
Export NOB > save file3Manual list
Export NOB -> save fileCreate Nob RIUs file for DL? -> No
Open file taken from (2)File -> attach from (3)
Save as …… IDT
3
4
Export NOB -> save fileCreate Nob RIUs file for DL? -> Yes
Upload REMINV
© Siemens, 2005Page 32
p
Inventory using Excel finish
![Page 33: BS241 Commissioning](https://reader034.fdocuments.net/reader034/viewer/2022050712/5513a5364a7959f1028b4d1d/html5/thumbnails/33.jpg)
Data InventoryDocument Holder
BS-240
BS 240 IIBS-240 II
© Siemens, 2005Page 33
![Page 34: BS241 Commissioning](https://reader034.fdocuments.net/reader034/viewer/2022050712/5513a5364a7959f1028b4d1d/html5/thumbnails/34.jpg)
Data InventoryUpload REMINV
© Siemens, 2005Page 34
![Page 35: BS241 Commissioning](https://reader034.fdocuments.net/reader034/viewer/2022050712/5513a5364a7959f1028b4d1d/html5/thumbnails/35.jpg)
Data InventoryDownload REMINV
© Siemens, 2005Page 35