Brodski strojni sustavi .pdf
description
Transcript of Brodski strojni sustavi .pdf
![Page 1: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/1.jpg)
BRODSKI STROJNI SUSTAVI
SUSTAVI OPĆE SLUŽBE(protupožarni sustavi)
![Page 2: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/2.jpg)
Uzroci požara na brodu
Otvorena vatraElektrični kratki spojSamozapaljenje “stupe”Plin praskavacPrskanje goriva na tople površ.Razne druge upaljive tvariUdari eksplozivnih tvari
![Page 3: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/3.jpg)
Konstruktivne PP mjere
SOLAS, registartoplinske i strukturne pregrade dijele brod naglavne vert. zoneodijeljenost stambenih prostoragorive tvari ograničeneotkrivanje, zadržavanje i gašenje požara u zoni nastankaizlaz za slučaj nužde ili pristup u nuždibrzo gašenjesmanjiti mogućnost zapaljivanja
![Page 4: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/4.jpg)
Konstruktivne PP mjere
negorivi materijal (750°C)pregrade 40mpregradna paluba - do koje sežupoprečne nepropusne pregradeplanovi PP zaštitemeđunarodna priključnica
![Page 5: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/5.jpg)
Plan PP zaštite
jasno izloženi opći planoviupute za održavanje i rukovanjepokazuju:– kontrolne stanice– uređaj za požarnu uzbunu– vatrodojavne uređaje– sredstva za gašenje
![Page 6: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/6.jpg)
Osnove gašenja
oduzimanjem jednog od 3 uvjetapotrebnih za proces gorenjauklanjanje gorive tvari (ili postavljanjeprepreka širenju požara)gušenjem (O2)hlađenjem ispod temp. paljenjakemijskom reakcijom (antikatalitičkodjelovanje)
![Page 7: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/7.jpg)
Sredstva za gašenje
osnovno - vodaspecijalna (CO2, halon*, pjena, prah)pomoćna (pijesak, prekrivači..)
Ugrađeni protupožarni uređaji uvode sredstvo za gašenje u prostoriju u kojoj je požar u takvom obliku i količini kojaosigurava efikasno gašenje.
![Page 8: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/8.jpg)
Sustavi gašenja požara
Prema HRB: – rasprskivanje, – raspršivanje (engl. water mist→hi-fog), – vodene zavjese – RO-RO teret,– rošenje – spremište eksploziva, – pjena, inertni plin – tankovi– CO2, voda, suhi prah– haloni i zamjene
![Page 9: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/9.jpg)
Glavni PP sustav
Tlak na hidrantima više od 2bar (ovisno o nosivosti)Q - ovisi o dimenzijama broda, ali barem 25m3/hsmještaj ispod lake vodne linijecjevovod: 140m3/hhidranti (u zatvorenom 20m udaljenosti, na otvorenom 40m)
![Page 10: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/10.jpg)
Glavni PP sustav
Q=k·m2
d=0,8 ·m m=1,68 ·[L ·(B+D)]1/2+25proračunski tlak 1 MPa
![Page 11: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/11.jpg)
PP cijevi
Putnički: 1 PP cijev za 1 PP ventilTeretni: 1/ 25 m, ne manje od 5/≥1000 t i ne manje od 3/<1000 tstandardizirane spojke
![Page 12: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/12.jpg)
PP mlaznice
promjer 12, 16 ili 19 mmmlaz i raspršivanje, zaporni org.mogu biti i plastične
![Page 13: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/13.jpg)
PP pumpa za nuždu
nezavisni pogonodvojeni smještajupravljanje lokalno i s otkrivene palubegoriva za 3 h rada (+15 h)tlak u skladu s dimenzijamakapacitet prema dim. trupa, ali ne manje od 40% QGPP
dvije ručne mlaznice s max. otvorom
![Page 14: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/14.jpg)
Sustav za gašenje s CO2
plin bez boje i mirisaiznad 5% ugušujuće na ljude →postupak1,5 puta teži od zraka – ugušivanjene provodi strujugašenje svih požara osim lakih metala (Al, Mg i legure)zatvoreni prostori (skladišta, prostori strojeva)visoko- i niskotlačni sustavboce se ispituju vaganjem (10% gubitka)
![Page 15: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/15.jpg)
Sustav za gašenje s CO2
Količina se određuje prema:G=1,79Vφ gdje je φ
za skladište 0,3 (0,45 vozila)za strojarnicu: 1) 0,4 volumena najvećeprostorije bez grotlišta (do visine na kojoj jepovr. gr.40%); 2) 0,35 volumena najvećeprostorije uključujući i grotlište
Volumen slobodnog CO2 = 0,56 m3/kg
85% za 2min u strojarnicu; 67% za 10 min za skl. vozila na RO-RO
![Page 16: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/16.jpg)
Sustav za gašenje s CO2
- smještaj bitnih dijelova?
![Page 17: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/17.jpg)
Sustav za gašenje s CO2
- dojava - cijevni detektor dima
Propeler , perce, kuglica i sl. indiciraju protok zraka.
![Page 18: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/18.jpg)
Sustav za gašenje s CO2
Dojavljivanje na modernim sustavima iz svakog prostorapojedinačno.
![Page 19: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/19.jpg)
Sustav za gašenje s CO2
![Page 20: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/20.jpg)
Postupak gašenja s CO2 sustavom u strojarnici
alarm→napuštanje strojarniceisključivanje ventilacije*zaustavljanje pumpi, separatora...zatvaranje ventila goriva i mazivaotvaraju se oba ventila u kontrolnojstanici i na pilot boci
Strojarnica se smije ventilirati nakon 36 sati ili više.
![Page 21: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/21.jpg)
Pjena
mješavina vode, pjenila i zrakagasi gušenjem*prema koncentraciji (ekspanzijski omjer): laka, srednje teška i teška pjenalaka (high exp.): omjer od 1:201 do 1:1000monitori koji dobavljaju i do 1000 m3/minmasni alkoholigasi požare klase A,B,C, E; moguć kraći boravak osoba
![Page 22: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/22.jpg)
Pjena
gustoće ≈1kg/m3
na 100 l mješ. 80000 l zrakasrednje teška (medium exp.): omjeri od1:21 do 1:200 (češće od 1:40 do 1:50)domet do 12 m, ρ=11 kg/m3
skladišta boja, pumpne stanice, u slučajupožara kod probijanja tankerasintetska pjenilana 100 l mješ. ide 15000 l zraka
![Page 23: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/23.jpg)
Pjena
Teška pjena (low exp.): omjeri od 1:4 do 1:20 (češće od 1:5 do 1:7)težine 150 kg/m3, velik domethvata se na okomite stjenketankeribjelančevine životinjskog por.vode do 8%na 100 l mješ. ide 700 l zrakanedostaci: korozija, vrijeme
Na kemijskim t. alkoholna pjena
![Page 24: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/24.jpg)
Sustav gašenja pjenom
Strojarnica, PS, tankovi-palubastrojarnica
teška pj.: 5 min, eks. 1:12, visina 150 mm iznadnajveće ravne površine prelijevanja
laka pj.: visina 1 m/min, količina pjenila = 5x volumen najveće prostorijena tankerima
pokrivanje cijele površine palube tankova i svakiprobijeni tank
upravljanje izvan palube tereta
![Page 25: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/25.jpg)
Sustav gašenja pjenom
tankeri sa ugrađenim IG = 20 mintankeri bez ugrađenog IG = 30 minomjer ne veći od 1:12fiksni gen. pjene 1250 l/min L i Dprijenosne naprave min. 400 l/min i min. 15 m dometanajmanje 4 prijenosne naprave
![Page 26: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/26.jpg)
Sustav gašenja pjenom
![Page 27: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/27.jpg)
Sustav gašenja pjenom
![Page 28: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/28.jpg)
Doziranje pjenila
linijski mješač - ejektorprimarno-sekundarni mješačmješač s obilaznim vodomelektronsko doziranjetlačni (membranski) mješač
![Page 29: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/29.jpg)
Doziranje pjenila
![Page 30: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/30.jpg)
Doziranje pjenila
![Page 31: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/31.jpg)
Halon
Derivati metana i etana uz halogene el. F, Cl, Br, JH1301 = 1c, 3f, 0o, 1bH1211, H2402požari klase A, B, C, E≈3x efikasniji od CO2minimalna toksičnost (H1301 7%)zatvoreni prostoriantikatalitičko djelovanje - 5%
Oštećuju ozonski omotač
![Page 32: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/32.jpg)
Halon 1301
djeluje na centralni nervni sist. i kardiovaskularni sist.u ovisnosti u % H1301 u atm. dozvoljeno jevrijeme izlaganja:
opasne kiseline HF, HBr te Br2
vol[%]
<7
7-10
10-15
>15
vrijeme [min]
15
1
0,5
opasno
![Page 33: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/33.jpg)
Halon 1211
6 puta teži od zraka3 puta toksičniji od H1301rjeđe se koristi u prostorijama u kojimaboravi čovjek
Postupak: ako se koristi 1301 s 10% konc. treba alarm i napuštanje prostorije za <30s ako ne (7%) samo alarm
![Page 34: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/34.jpg)
Sustav s halonom
Spremnici pod tlakom dušika (1301 ne treba,ali se ipak tako izvode)strojarnica, PS, prostorije za prijevoz vozilabez tereta<20 s za izbacivanjeH1301 za 5-7% volumena prostorije, H1211 treba veće koncentracije, H2402 treba 0,2-0,3 kg/m3
spremnici od 25 ili 42 bar ±5%vaganje=>10% ili manometar
![Page 35: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/35.jpg)
Sustav s halonom
![Page 36: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/36.jpg)
Prah
univerzalno sredstvo (različiti sulfati i karbonati - Na, K, NH3)gušenje najvažniji efekt (CO2), djeluje i antikatalitički (soda) i hladi (vodenapara)zaštita i od zračenja toplineizbacivanje pomoću CO2 ili N2
![Page 37: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/37.jpg)
Sustav gašenja prahom
tankeri za prijevoz plina i kemikalijapohranjen u jednom ili više spremnikapogonski plin u posebnim spr.smještaj u prostorijama koje ne mogubiti ugrožene požarom
![Page 38: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/38.jpg)
Sustav gašenja prahom
zatvoreni pr.=>30s ukupna masa prahateret, cjev. tereta, ukrc/iskrcdvije stanice (1 spremnik dovoljan za 45s rada svih ručnih mlaznica i topova 1 stanice)ručne 3,5kg/s i 8m dometatopovi min 10kg/s i 10m (veći su 25 i 45kg/s s 30 i 40m)spremnici se čuvaju na temp. ispod 45°C
![Page 39: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/39.jpg)
Postupak
alarm za napuštanjeisključivanje prisilne ventilacijezatvaranje ventilacijskih otvoraradni tlak u spremniku mora se postići za neviše od 20s (to je cca 12bar)uređ. pod naponom mora se gasiti nasigurnoj udaljenostinakon upotrebe cjevovod se propuhuje s CO2 ili N2
![Page 40: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/40.jpg)
Sustav gašenja prahom
![Page 41: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/41.jpg)
Sustav gašenja prahom
![Page 42: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/42.jpg)
Automatski sustav za gašenje prskanjem - voda
gasi hlađenjemprednosti
- dostupna količina- lagan tansport- oblici primjene- neotrovna
nedostaci- vodi električnu struju- na visokoj temperaturi može se raspasti na
vodik (gorivo) i kisik
![Page 43: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/43.jpg)
Automatski sustav za gašenje prskanjem - voda- kemijski reagira - acetilen- razlivanje zapaljenih tekućina- oštećenje opreme
![Page 44: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/44.jpg)
Sprinkler sustav
gašenje u putničkim i prostorijamaposadesvaka sekcija raspr. - alarmstambene prost.: 68°C i 79 °C brzina rasprskivanja ne manja od 5 l/m2
tlak za najmanje 28 m2
suhi i mokri sustav
![Page 45: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/45.jpg)
Sprinkler sustav
![Page 46: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/46.jpg)
Sprinkler – suhi i mokri sustav
![Page 47: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/47.jpg)
Sprinkleri (rasprskači) - izvedbe
![Page 48: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/48.jpg)
Zamjena za halone
inergen, FE-13, FM-200, NAF-S…
![Page 49: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/49.jpg)
Inergen
mješavina tri prirodna plina: dušik, argon i ugljik dioksidne provodi el. strujusiguran za primjenu u prostorima s ljudimane oštećuje el. opremune oštećuje ozon, ne utječe na globalno zatopljenje, ne traje u atmosferi
![Page 50: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/50.jpg)
Inergen
smanjuje udio kisika do mjere do koje atmosfera ne podržava gorenje, ali podržava životsmješta se u spremnike blizu mjesta primjene
![Page 51: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/51.jpg)
FM-200
heptafluoropropan, HFC-227easiguran za ljudezamjena za Halon 1301
![Page 52: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/52.jpg)
FE-13
razvijen kao rashladno sredstvomolekule apsorbiraju toplinu, ali djelomično djeluje i kao halon 1301 -kemijskiidealan za prostore s ljudima
![Page 53: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/53.jpg)
Sustav raspršivanja
visokotlačni i srednjetlačni sustavikapljice ulja “štiti” tanki film vodevisokotlačni sustav: prost. strojevasrednjetlačni sustavi: paluba vozila i sl.sustav podijeljen u sekcije ručnim ventilimarazvoj: “hi-fog” sustav
![Page 54: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/54.jpg)
“Hi-fog”
gasi hlađenjem, gušenjem, kapljice vode vezuju se s česticama gorive tvari
Broj kapljica
Promjer kapljice
Površina Vrijeme isparivanja
Sprinkler 1 1 mm 1 1 s
Water myst 40 0,3 mm 10 0,1 s
Hi-fog 8000 0,005 mm 400 0,003 s
![Page 55: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/55.jpg)
“Hi-fog”
požari klase A, B, C, Euklanja kisik samo u blizini požara –lokalnonepotrebno napuštanje prostora prije gašenja = brzina postupka
![Page 56: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/56.jpg)
Hi-fog
razlike u postupkukarakteristike hi-fog sustavavideo
![Page 57: Brodski strojni sustavi .pdf](https://reader031.fdocuments.net/reader031/viewer/2022033009/55cf9b53550346d033a599f4/html5/thumbnails/57.jpg)
Zadaci
Odrediti potreban broj visokotlačnih spremnika CO2 za strojarnicu. Strojarnica s dijelom grotlišta (visina na kojoj površina poprečnog presjeka iznosi 40%) ima volumen 5000 m3, a s cijelim grotlištem 5500 m3.Odrediti promjer glavnog kolektora CO2 te debljinu stjenke.