Broadband PLC for Smart Communication
Infrastructure
2014/12/15 1
December 10th 2014
Kyushu Institute of Technology Mikio Mizutani
![Page 2: Broadband PLC for Smart Communication …...Broadband PLC for Smart Communication Infrastructure 1 2014/12/15 December 10th 2014 Kyushu Institute of Technology Mikio Mizutani 1.](https://reader030.fdocuments.net/reader030/viewer/2022013021/5f119bd4e369284cb63b1283/html5/thumbnails/2.jpg)
1.Introduction
2014/12/15 2
![Page 3: Broadband PLC for Smart Communication …...Broadband PLC for Smart Communication Infrastructure 1 2014/12/15 December 10th 2014 Kyushu Institute of Technology Mikio Mizutani 1.](https://reader030.fdocuments.net/reader030/viewer/2022013021/5f119bd4e369284cb63b1283/html5/thumbnails/3.jpg)
PLC is used for Home-Network
2014/12/15 3
Nature of Power Line Communication # No new wiring=Power Line is ubiquitous # Connect to Power Supply Network # Over 100Mbps capability available PLC application & required rate # Router to PC 100Mbps required # Router to TV (Broadcast) 24Mbps necessary # Router to Telephone less than 100mS delay # Smart Meter to HEMS-GW 1kbytes/minute # Auto-Meter-Reading 100bytes/month
![Page 4: Broadband PLC for Smart Communication …...Broadband PLC for Smart Communication Infrastructure 1 2014/12/15 December 10th 2014 Kyushu Institute of Technology Mikio Mizutani 1.](https://reader030.fdocuments.net/reader030/viewer/2022013021/5f119bd4e369284cb63b1283/html5/thumbnails/4.jpg)
PLC applications
2014/12/15 4
Internet
Smart Meter
Gas
Water
Fiber Cable
Appliances
Battery
DC to AC
Pow
er L
ine
EV
Router
Ethernet PLC
Power Control RS232C PLC
RS232C PLC
RS232C PLC
Ethernet PLC
Ethernet PLC
Ethernet PLC
Ethernet PLC
RS232C PLC
![Page 5: Broadband PLC for Smart Communication …...Broadband PLC for Smart Communication Infrastructure 1 2014/12/15 December 10th 2014 Kyushu Institute of Technology Mikio Mizutani 1.](https://reader030.fdocuments.net/reader030/viewer/2022013021/5f119bd4e369284cb63b1283/html5/thumbnails/5.jpg)
2.Physical layer of PLC & Noise/Attenuation
2014/12/15 5
Doctoral dissertations of Mikio Mizutani ;Kyushu Institute of Technology 2014 ‘Studies on Reinforcement of Power Line Communications on Home Networks’
![Page 6: Broadband PLC for Smart Communication …...Broadband PLC for Smart Communication Infrastructure 1 2014/12/15 December 10th 2014 Kyushu Institute of Technology Mikio Mizutani 1.](https://reader030.fdocuments.net/reader030/viewer/2022013021/5f119bd4e369284cb63b1283/html5/thumbnails/6.jpg)
PLC-standards in Japan
2014/12/15 6
Broad-band PLC:BPLC≒120Mbps Narrow-band PLC:NPLC≒30kbps
BPLC-standard IEEE1901,ITU-T G.9972 (2011) Application in Japan is limited to use only in-house NPLC-standard IEEE1901.2,ITU-T G.9903-ARIB(2014) TEPCO start to use for Smart-Meter from 2015 Spring
AC-line noise
![Page 7: Broadband PLC for Smart Communication …...Broadband PLC for Smart Communication Infrastructure 1 2014/12/15 December 10th 2014 Kyushu Institute of Technology Mikio Mizutani 1.](https://reader030.fdocuments.net/reader030/viewer/2022013021/5f119bd4e369284cb63b1283/html5/thumbnails/7.jpg)
OFDM Modulation is better for wideband
2014/12/15 7
In deeply-notched-spectrum-line, OFDM is less damaged than Single-Carrier system.
OFDM Single-Carrier-PSK
Line spectrum
![Page 8: Broadband PLC for Smart Communication …...Broadband PLC for Smart Communication Infrastructure 1 2014/12/15 December 10th 2014 Kyushu Institute of Technology Mikio Mizutani 1.](https://reader030.fdocuments.net/reader030/viewer/2022013021/5f119bd4e369284cb63b1283/html5/thumbnails/8.jpg)
Typical Line-Attenuation is Low-Pass in high rise housing vertical cable.
2014/12/15 8
1st 2nd 3rd 4th
Observed line attenuation 1st to 4th
Simulated line attenuation Total line attenuation 1st to 4th
25mm2 cable model + LED-bulb
![Page 9: Broadband PLC for Smart Communication …...Broadband PLC for Smart Communication Infrastructure 1 2014/12/15 December 10th 2014 Kyushu Institute of Technology Mikio Mizutani 1.](https://reader030.fdocuments.net/reader030/viewer/2022013021/5f119bd4e369284cb63b1283/html5/thumbnails/9.jpg)
Diode bridge noise is limit under 10kHz.
2014/12/15 9
Diode bridge in power-supply
Noise wave of Diode bridge
Diode bridge has no damage for NPLC
![Page 10: Broadband PLC for Smart Communication …...Broadband PLC for Smart Communication Infrastructure 1 2014/12/15 December 10th 2014 Kyushu Institute of Technology Mikio Mizutani 1.](https://reader030.fdocuments.net/reader030/viewer/2022013021/5f119bd4e369284cb63b1283/html5/thumbnails/10.jpg)
2014/12/15 10
Over 150kHz noise has damages for NPLC
Equipment with dimmer has over 150kHz noise.
Japan regulation of AC-noise Noise of KOTATSU with dimmer
![Page 11: Broadband PLC for Smart Communication …...Broadband PLC for Smart Communication Infrastructure 1 2014/12/15 December 10th 2014 Kyushu Institute of Technology Mikio Mizutani 1.](https://reader030.fdocuments.net/reader030/viewer/2022013021/5f119bd4e369284cb63b1283/html5/thumbnails/11.jpg)
2014/12/15 11
IH-noise is burst in every 20mS cause error in NPLC.
IH-cooking-heater power-supply-burst-noise exceed 150kHz.
IH-cooking-heater-Noise
Display of G3plc_monitor By Egretcom
![Page 12: Broadband PLC for Smart Communication …...Broadband PLC for Smart Communication Infrastructure 1 2014/12/15 December 10th 2014 Kyushu Institute of Technology Mikio Mizutani 1.](https://reader030.fdocuments.net/reader030/viewer/2022013021/5f119bd4e369284cb63b1283/html5/thumbnails/12.jpg)
2014/12/15 12
Impedance up/down by 50Hz
Wave of Impedance up/down Packet-error-ratio vs. 0-cross of 50Hz
Error ratio
Packet-error-ratio varies from 0% to 100% depend on AC-wave zero-cross timing.
0 0.005 0.01 0.015 0.02-0.02
-0.015
-0.01
-0.005
0
0.005
0.01
0.015
0.02
時間[sec]
電圧
[V]
50Hz*2
![Page 13: Broadband PLC for Smart Communication …...Broadband PLC for Smart Communication Infrastructure 1 2014/12/15 December 10th 2014 Kyushu Institute of Technology Mikio Mizutani 1.](https://reader030.fdocuments.net/reader030/viewer/2022013021/5f119bd4e369284cb63b1283/html5/thumbnails/13.jpg)
3. G3PLC & real environment
2014/12/15 13
![Page 14: Broadband PLC for Smart Communication …...Broadband PLC for Smart Communication Infrastructure 1 2014/12/15 December 10th 2014 Kyushu Institute of Technology Mikio Mizutani 1.](https://reader030.fdocuments.net/reader030/viewer/2022013021/5f119bd4e369284cb63b1283/html5/thumbnails/14.jpg)
2014/12/15 14
FCH-no-error EQM=0
G3PLC-ARIB frame in real environment-1. no-ATT & no-noise
![Page 15: Broadband PLC for Smart Communication …...Broadband PLC for Smart Communication Infrastructure 1 2014/12/15 December 10th 2014 Kyushu Institute of Technology Mikio Mizutani 1.](https://reader030.fdocuments.net/reader030/viewer/2022013021/5f119bd4e369284cb63b1283/html5/thumbnails/15.jpg)
2014/12/15 15
FCH-no-error EQM=294
G3PLC-ARIB frame in real environment-2. Flat-ATT 55dB=SN 0dB
![Page 16: Broadband PLC for Smart Communication …...Broadband PLC for Smart Communication Infrastructure 1 2014/12/15 December 10th 2014 Kyushu Institute of Technology Mikio Mizutani 1.](https://reader030.fdocuments.net/reader030/viewer/2022013021/5f119bd4e369284cb63b1283/html5/thumbnails/16.jpg)
2014/12/15 16
FCH-no-error EQM=582
G3PLC-ARIB frame in real environment-3. Line=180kHz low-pass
![Page 17: Broadband PLC for Smart Communication …...Broadband PLC for Smart Communication Infrastructure 1 2014/12/15 December 10th 2014 Kyushu Institute of Technology Mikio Mizutani 1.](https://reader030.fdocuments.net/reader030/viewer/2022013021/5f119bd4e369284cb63b1283/html5/thumbnails/17.jpg)
2014/12/15 17
FCH-FCS-error EQM=759.
G3PLC-ARIB frame in real environment-4. IH-cooking-heater-burst-noise
![Page 18: Broadband PLC for Smart Communication …...Broadband PLC for Smart Communication Infrastructure 1 2014/12/15 December 10th 2014 Kyushu Institute of Technology Mikio Mizutani 1.](https://reader030.fdocuments.net/reader030/viewer/2022013021/5f119bd4e369284cb63b1283/html5/thumbnails/18.jpg)
4. HD-PLC performance issue
2014/12/15 18
Mikio Mizutani, Masato Tsuru, Yuji Oie, “New Performance Estimation Scheme and Applications for Broadband Communications Over Power Lines in the Home,” Proc. 2011 IEEE Pacific Rim Conference on Communications, Computers and Signal Processing (PACRIM2011), pp. 578-583, August 2011.
![Page 19: Broadband PLC for Smart Communication …...Broadband PLC for Smart Communication Infrastructure 1 2014/12/15 December 10th 2014 Kyushu Institute of Technology Mikio Mizutani 1.](https://reader030.fdocuments.net/reader030/viewer/2022013021/5f119bd4e369284cb63b1283/html5/thumbnails/19.jpg)
Panasonic PLC house in Minoshima
2014/12/15 19
Number of outlets is 84
![Page 20: Broadband PLC for Smart Communication …...Broadband PLC for Smart Communication Infrastructure 1 2014/12/15 December 10th 2014 Kyushu Institute of Technology Mikio Mizutani 1.](https://reader030.fdocuments.net/reader030/viewer/2022013021/5f119bd4e369284cb63b1283/html5/thumbnails/20.jpg)
Observed UDP-rate in PLC house
2014/12/15 20
UDP-rate vs. Attenuation in each 13 pairs of outlet
![Page 21: Broadband PLC for Smart Communication …...Broadband PLC for Smart Communication Infrastructure 1 2014/12/15 December 10th 2014 Kyushu Institute of Technology Mikio Mizutani 1.](https://reader030.fdocuments.net/reader030/viewer/2022013021/5f119bd4e369284cb63b1283/html5/thumbnails/21.jpg)
UDP rate Estimation of every outlet pairs
2014/12/15 21
Attenuation estimation by BMAE Estimated UDP rate of every outlet pairs
![Page 22: Broadband PLC for Smart Communication …...Broadband PLC for Smart Communication Infrastructure 1 2014/12/15 December 10th 2014 Kyushu Institute of Technology Mikio Mizutani 1.](https://reader030.fdocuments.net/reader030/viewer/2022013021/5f119bd4e369284cb63b1283/html5/thumbnails/22.jpg)
UDP rate up by relay transmission
2014/12/15 22
Rate up criteria Sac>Sab*2 & Scb>Sab*2
UDP rate up by relay transmission RED: no improve Blue: Rate up
Relay transmission improve UDP rate. 100% up-12Mbps :95% up-20Mbps : 90% up-24Mbps
![Page 23: Broadband PLC for Smart Communication …...Broadband PLC for Smart Communication Infrastructure 1 2014/12/15 December 10th 2014 Kyushu Institute of Technology Mikio Mizutani 1.](https://reader030.fdocuments.net/reader030/viewer/2022013021/5f119bd4e369284cb63b1283/html5/thumbnails/23.jpg)
Thanks your corporation
2014/12/15 23