BOT306RF-WIFI Boiler Thermostat - Beok Controls

3
VI . Operation Instruction Temperature Sensor Limiting Temperature Range Temperature Control Accuracy Working Voltage Current Load Setting Temperature Range NTC ±1ºC 1. 5Vx2( Two sections of 1.5V 5 battery) 3A Consumption 5-60I. Product Summary: II. Technical Parameter: IV. User Interface Explanation BOT SERIES BOILER THERMOSTAT III. Main Button Instruction V. Model Spec BOT-W306 BOT-X306 BOT series boiler thermostats are with LCD digital display big screen, and it is developed according to market’s requirements. Thermostats can be installed on the wall, or directly put on the table. This series thermostats are easy to operate, and with complete functions. It can be used to control boilers, motorized ball valves, motorized valves, electric valves, solenoid valves, etc. Output power can be made 220V/110V 5-99ºC <0.3W : ON/OFF Switch; :Mode Button. Switch between Manual Mode, Auto Period Control Mode, Temporary Manual Mode. Long press to enter period setting. :Time Set. Hour, minute and week setting; :Up Button. To increase temperature. When press it with and it can set programmable function; :Down Button. To reduce temperature. When press it with and it can set programmable function; : : Key Lock. Long press 5 seconds to lock or unlock; Model Wi-Fi Function Wireless Function Terminal Receiver :Manual Control. :Temporary Manual Control. :Auto Control. :Heating. :First Period. Wake up in the morning. :Second Period. Out of home in the morning. :Third Period. Go home in the afternoon. :Forth Period. Out of home in the afternoon. :Fifth Period. Go home in the evenning. Open/Close State Power Power Indicator Light State Indicator Light Switch Indicator Light :Sixth Period. Sleep in the evening. Time Setting Press , the time area will display Minute, Hour and Week, then press or to modify time. Programmable Period Temperature Setting 6 periods every day in a week 5+2 Controls 1 2 3 4 5 6+1 Controls 1 2 3 4 5 6 7+0 Controls 1 2 3 4 5 6 7 A Week Loop Control 3. Press one time, time twinkles, you can set the time during this period. time during this period. 1. After Power is on, long press 5 seconds to enter period program. Loops means a Week loop. 2. Press again, room temperature display and twinkle, you can set the temperature during this period. 4. Press again, to set the next period temperature and time with the same method. First step, long press , screen display LooP(Cycling Control), screen displays 12345 (From Monday to Friday); Press one time, it displays 123456(From Monday to Saturday); Press two times, it displays 1234567(From Monday to Sunday); Second step, time and temperature setting in every period. When screen display 12345 or 123456 or 1234567, press to enter temperature setting. Press to enter time setting. To modify and save through or . Att: When auto-control ,if user needs to reset the temperature, it can be changed to temporary manual control. Temporary manual control means when thermostat is in auto-control mode(program mode), user press or to modify temperature setting, thermostat now is in temporary manul control state. When next periods comes, thermostat will automatically return to acquiescent period program control mode. Programmable Period Time Setting First press , then press to change to time options, user can modify time in the period. Default Program Data Period Default Time Default Temperature Icon 1 2 3 4 5 6 Workday Weekends 1 2 06:00 08:00 11:30 12:30 17:30 22:00 08:00 23:00 2015152222151515Att : 1. The default temperature values of 3 and 4 period in workday is same with 2 period. If user need, please change this default temperature. 2. Setting temperature is 00, it means this period is power off. Set, or modify parameter : Anti-frozed function open. BOT306RF-WIFI VII. Advanced Setting In the state of power-off, long press and hold then press into advanced setting mode. Then press to set relative item. Firstly, press time button Then, press power button After entering advanced setting, press to choose next parameter changing.

Transcript of BOT306RF-WIFI Boiler Thermostat - Beok Controls

VI. Operation Instruction

Temperature Sensor

Limiting Temperature Range

Temperature Control Accuracy

Working Voltage

Current Load

Setting Temperature Range

NTC

±1ºC

1.5Vx2(Two sections of 1.5V 5 battery)

3A

Consumption

5-60℃

I. Product Summary:

II. Technical Parameter:

IV. User Interface Explanation

BOT SERIES BOILER THERMOSTAT

III. Main Button Instruction

V. Model Spec

BOT-W306

BOT-X306

BOT series boiler thermostats are with LCD digital display big screen, and it is developed according to market’s requirements. Thermostats canbe installed on the wall, or directly put on the table. This series thermostats are easy to operate, and with complete functions. It can be used to control boilers, motorized ball valves, motorized valves, electric valves, solenoid valves, etc.

Output power can be made 220V/110V

5-99ºC

<0.3W

: ON/OFF Switch;

:Mode Button. Switch between Manual Mode, Auto Period Control Mode, Temporary Manual Mode. Long press to enter period setting.

:Time Set. Hour, minute and week setting;

:Up Button. To increase temperature. When press it with and it can set programmable function;

:Down Button. To reduce temperature. When press it with and it can set programmable function;

:

: Key Lock. Long press 5 seconds to lock or unlock;

Model Wi-Fi FunctionWireless Function Terminal Receiver

:Manual Control. :Temporary Manual Control. :Auto Control.

:Heating.

:First Period. Wake up in the morning.

:Second Period. Out of home in the morning.

:Third Period. Go home in the afternoon.

:Forth Period. Out of home in the afternoon.

:Fifth Period. Go home in the evenning.

Open/Close State Power

Power Indicator Light

State Indicator Light

Switch Indicator Light

:Sixth Period. Sleep in the evening.

Time Setting

Press , the time area will display Minute, Hour and Week, then press or to modify time.

Programmable Period Temperature Setting

6 periods every day in a week

5+2 Controls 1 2 3 4 56+1 Controls 1 2 3 4 5 67+0 Controls 1 2 3 4 5 6 7

A Week Loop Control

3. Press one time, time twinkles, you can set the time during this period. time during this period.

1. After Power is on, long press 5 seconds to enter period program. Loops means a Week loop.2. Press again, room temperature display and twinkle, you can set the temperature during this period.4. Press again, to set the next period temperature and time with the same method.

First step, long press , screen display LooP(Cycling Control), screendisplays 12345 (From Monday to Friday); Press one time, it displays123456(From Monday to Saturday); Press two times, it displays 1234567(From Monday to Sunday);

Second step, time and temperature setting in every period. When screendisplay 12345 or 123456 or 1234567, press to enter temperature setting.Press to enter time setting. To modify and save through or .Att: When auto-control ,if user needs to reset the temperature, it can be changed to temporary manual control. Temporary manual control meanswhen thermostat is in auto-control mode(program mode), user pressor to modify temperature setting, thermostat now is in temporary manulcontrol state. When next periods comes, thermostat will automaticallyreturn to acquiescent period program control mode.

Programmable Period Time Setting

First press , then press to change to time options, user can modify time in the period.

Default Program Data

Period Default Time Default TemperatureIcon

1

23

4

5

6

Workday

Weekends12

06:0008:0011:30

12:30

17:30

22:00

08:00

23:00

20℃

15℃

15℃

22℃

22℃

15℃

15℃

15℃

Att:1.The default temperature values of 3 and 4 periodin workday is same with 2 period. If user need, please change this default temperature.

2. Setting temperature is 00, it means this period is power off.

Set, or modify parameter

: Anti-frozed function open.

BOT306RF-WIFI

VII. Advanced Setting

In the state of power-off, long press and hold then press into advanced setting mode. Then press to set relative item.

Firstly, press time button

Then, press power button

After entering advanced setting, press to choose next parameter changing.

Display Code Function Setting And Options Factory Default

dIF Limit temp. returndifference

0.5-4.5℃ 2℃

SVHSet temp. upper Limit

5-99℃ 35℃

SVL 5-99℃ 5℃

AdJ Measure temp.-5-5℃(0.5℃accuracycorrection)

0.0℃

FrE Anti-frozen00:Close anti-frozen

01:Open anti-frozen 00

LOC Button lock function

00: Unlock01: except power switch, all buttons are locked02: All buttons are locked

00

SNPSet Sequence Number

0

FAC Factory setting 08:Just display00:Return to factory setting 08

Set temp. low limit

00:Close this function

01:Open this function

VIII. Wiring Diagram

NC:Normally Closed Interface

(Boiler or Loading) ;

COM:Common Interface

(Boiler or external power input) ;

NO:Normally Open Interface

(Boiler or Loading) ;

Att:

Installation wires should be changed to be 1.5-2.5mm² hard line. Please rightly connect the wires strictly according to the connect diagram.Don’t make water, mud and other debris into the thermostat, otherwiseit will damage the thermostat.

The button inside receiver is Reset button. When status indicator light stay on or not on, user can press reset button to resume normal work.

IX. WIFI Configure

1. Install APP on phone

For iOS system: Login in App Store, search “ Beok RF Boiler”, you can download it on your iphone.

For Android System: Login in Google Play, search “ ”, you can download it on your phone.

Beok RFBoiler

2. Connection Thermostat with Phone

Thermostat Setting

Turn-off Press UP button for 10 seconds

1. Download and Install APP on phone.2. Press thermostat button for 10 seconds when thermostat is in turn-off state, then WIFI signal will appear and quickly twinkle. 3. Enter your wifi name and password, then start connection configure.

Press Configure key

Press Search key

APP Interface on the Phone

Thermostat Name

Return Refresh

Room Temperature

Heating State

Screen Locking

Anti-freezing

Long press into Advanced Setting

Manual/Auto mode

Power Switch

Period Display

Time Matching

Set TemperatureAdjustment(down)

Current Temperature

Set Temperature

Thermostat Setting through Phone Operation

1. Clock : You can press Time Matching switch to match your phone clock with thermostat clock.

2. Children lock (screen locking) : Press to lock the thermostat.

3. Anti-Freezing: Press thermostat will show on the screen , it means Anti-freezing function open.

4. Temperature setting: You can drag the pointer on Temperature Setting Dial to set temperature. Or press and to set temperature step.

directly >

5.Period setting: Long press Period Display, then you will go into the Period Setting mode:

v

v

Boiler Thermostat

XII. ATT:

Thank you for buying this product!

Please read this manual for complete instructions on installing and operating your thermostat. If you require further assistance, please feel free to contact us.

In the box you will find:

Thermostat

Receiver

User Manual

Screws

USB Cable

Our Service:

We offer the warranty of 24 months from the sales day.

During the warranty, if it is belong to the quality issue, we will fix or replace them for you by free after test them.

If it is not quality problem or beyond the warranty time, we will charge for the after-sales service.

BOT306 Series

BOT-X306BOT-W306

√√

Model

CHK(Check) Code

All SN are correct. CHK code is same.

The forth step, after SN is finished setting, if CHK Code is the same withbar code, it is correct. If not consistent, it is not correct. Please input again. 3.VAC: Control valves1-8 place numbers. The default value is 01.(This setting is only useful when thermostat is applied to control WirelessMain-Control Centralized Controller. If thermostat is used to control boiler, this setting must be 01.)

BEOK

XI. Set Sequence Number

1. Every thermostat has a matched receiver, and thermostat and receiver have a same group of sequence number. If user mix during installation, sequence number can be set through the following method.(Sequence number is unique)

2. In Advance Setting, SNP need to be set 01. Then to set SN through the following four steps.

1. Press button

2. Press button

The first step, press button under power off state, then press button, then press button to enter parameter setting;

Modify to be right numbers

The second step, after appearing SN1, press or to modify the number;

The third step, every time pressing once , it will appear SN2, SN3, SN4, SN5 and SN6 in order. Refer to second step, press or to modify.

Modify to be right numbers

Appear SN2-SN6 in order

Power Off State

6. Advanced Setting: Long Press Senior , you will go into Advanced setting mode:

7. Switch of Manual mode and Auto mode: Press to switch manual mode or Auto mode. 8.Power off : Press to turn on or off thermostat. X. Installation Instruction

Insert the equipped USB (Type-C) connector into the charger.

BOT306RF-WIFI

√√

Desktop Support Bracket(optional) √

Thermostat can be hung on the wall, or put on the table. User can choose one ofthem when he places an order. We will equip corresponding installation bracket and USB wire for user.

Wall-hung Support Bracket(optional) √