www.balluff.com 16 Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a.d.F. Germany Tel. +49 7158 173-0 Fax +49 7158 5010 [email protected] BNI IOL-309-000-K024 BNI IOL-310-000-K025 User‘s Guide    N   r  .    8    8    1    6    7    8    E   •    I   s   s   u   e    1    0    1    2   •    S   u    b    j   e   c    t    t   o   m   o    d    i          fi   c   a    t    i   o   n Balluff Network Interface / IO-Link BNI IOL IP20 Device

description

manual de equipo de festo

Transcript of BNI IOL-310-000-K025_EN

  • www.balluff.com16

    Balluff GmbHSchurwaldstrasse 973765 Neuhausen a.d.F.GermanyTel. +49 7158 173-0Fax +49 7158 [email protected]

    BNI IOL-309-000-K024BNI IOL-310-000-K025

    Users GuideNr

    .

    8

    8

    1

    6

    7

    8

    E

    I

    s

    s

    u

    e

    1

    0

    1

    2

    S

    u

    b

    j

    e

    c

    t

    t

    o

    m

    o

    d

    i

    fi

    c

    a

    t

    i

    o

    n

    Balluff Network Interface / IO-Link BNI IOL IP20 Device

  • www.balluff.com2

    1 Notes to the user

    1.1 About this guide 31.2 Structure of the guide 31.3 Typographical conventions 31.3.1 Enumerations 31.3.2 Actions 31.3.3 Syntax 31.3.4 Cross references 31.4 Symbol 31.5 Abbreviations 3

    2 Safety

    2.1 Intended use 42.2 General safety notes 42.3 Meaning of the warnings 4

    3 Getting Started

    3.1 Connection overview 53.2 Mechanical connection 63.3 Electrical connection 63.4 IO-Link Interface 63.5 Sensor-Hub Interface 63.6 Connection 6

    4 IO-Link Interface

    4.1 IO-Link data 74.2 Process data / Input Data 74.3 Parameter data / Request data 84.4 Errors 104.5 Events 10

    5 Technical Data

    5.1 Dimensions 115.2 Mechanical data 125.3 Electrical data 125.4 Operating conditions 12

    5.5 Function indicators 13

    Apendix

    Product ordering code 15 Order information 15

    Balluff Network Interface / IO-Link BNI IOL IP20 Device

    www.balluff.com 15

    Appendix

    Product orderingcode

    Order information Product ordering code Order code

    BNI IOL-309-000-K024 BNI004K

    BNI IOL-310-000-K025 BNI004L

    BNI IOL-3xx-000-xxxx

    Balluff Network Interface

    IO-Link Interface

    Functions309 = 8 Inputs/ Outputs can be parameterized310 = 16 Inputs/ Outputs can be parameterized

    Versions000 = Standard version

    Mechanical designK024 = plastic housing, rail mounting over plastics shell

    K025 = plastic housing, rail mounting over plastics shell

    Balluff Network Interface / IO-Link BNI IOL IP20 Device

  • www.balluff.com 3

    1 Notes to the user

    1.1 About this guide This guide describes the Balluff IO-Link Sensor-Hub. Connection to the superordinate IO-Link master assembly is established by means of IO-Link protocol. From functional perspective this compact and inexpensive module is comparable to a passive junction box: accepting digital and analogue sensor signals and conveying them through the IO-Link-Interface. 1.2 Structure of the The guide is organized so that the sections build on one another. guide Section 2: Basic safety information. Section 3: The main steps for installing the device. Section 4: IO-Link, parameter and process data for the device. Section 5: Technical data for the device.

    1.3 Typographical The following typographical conventions are used in this guide. conventions 1.3.1 Enumerations Enumerations are shown in list form with bullet points.

    - Entry 1, - Entry 2. 1.3.2 Actions Action instructions are indicated by a preceding triangle. The result of an action is indicated by an arrow. Action instruction 1 Action result. Action instruction 2.

    1.3.3 Syntax Numbers: Decimal numbers are shown without additional indicators (e.g. 123), Hexadecimal numbers are shown with the additional indicator hex (e.g. 00 hex).

    1.3.4 Cross references Cross references indicate where additional information on the topic can be found (see section 5 Technical Data)

    1.4 Symbols Note This symbol indicates general notes.

    Note! This symbol indicates a security notice which must be observed.

    1.5 Abbrevations BCD Binary coded switch BNI Balluff Network Interface DPP Direct Parameter Page EMV Electromagnetic Compatibility E-Port Digital Input-Port FE Function earth IOL IO-Link LSB Least Signifi cant Bit MSB Most Signifi cant Bit Sensor-Hub Sensor-Hub SP Switching point SPDU Service Protocol Data Unit

    Balluff Network Interface / IO-Link BNI IOL IP20 Device

    www.balluff.com14

    Balluff Network Interface / IO-Link BNI IOL IP20 Device

    Indicator Function

    Yellow Input/-Output signal = 1

    Out Input/-Output signal = 0

    5 Technical Data

    Status I/O LED 1...8/16

  • www.balluff.com4

    2 Safety

    2.1 Intended use This guide describes the Balluff Network Interface BNI IOL- for the application as peripheral in-/ output module to establish connection of binary standard sensors or actuators. Hereby it is about an IO-Link device which communicates by means of IO-Link protocol with the superordinate IO-Link master assembly. 2.2 General safety Installation and start up notes Installation and start up are to be performed only by trained specialists. Any damage resulting from unauthorized manipulation or improper use voids the manufacturers guarantee and warranty. The device complies with EMC Class A. Such equipment may generate RF noise. The operator must take precautionary measures accordingly. The device must be powered only using an approved power supply (see section 5 Technical data). Only approved cable may be used. Overvoltage or reverse polarity of connectors may damage the device.

    Operating and testing The operator is responsible for observing local prevailing safety regulations. When defects and non-clearable faults occur in the device, take it out of service and secure against unauthorized use. Approved use in ensured only when the housing is fully installed.

    2.3 Meaning of the Note! warnings The pictogram used with the word Caution warns against a possible hazardous situation affecting the health of persons or resulting in equipment damage. Ignoring these warnings can result in injury or equipment damage.

    Always observe the described measures for preventing this danger.

    Balluff Network Interface / IO-Link BNI IOL IP20 Device

    www.balluff.com 13

    Indicator Function

    Green AUX supply voltage is OK

    Out AUX supply voltage < 18V

    Indicator Function

    Green Module supply voltage is OK

    Green fl asing Module supply voltage < 18V

    Green, slowly fl ashig Overload, total current > 1A

    Out Module is without voltage

    Indicator Function

    Green No communication

    Green, negative pulsed Communication ok

    Red fl ashing Communication overload

    Out Module is without voltage

    Balluff Network Interface / IO-Link BNI IOL IP20 Device

    5 Technical Data

    5.5 LED Indicators

    LED Indicator Status LED 1

    Status LED 2

    Status LED 3/4

  • www.balluff.com 5

    3 First Steps

    3.1 Connection overview

    1 IO-Link Interface2 Port 1-8/16 Input/Output3 Port 1-8/16 24V4 Port 1-8/16 GND5 Status LED: Port 1-8/166 Status LED: Communication7 Status LED: Supply Module8 Status LED: Supply Module AUX

    Balluff Network Interface / IO-Link BNI IOL IP20 Device

    Figure 3-1: BNI IOL-309/310-000-K024/K025

    www.balluff.com12

    Balluff Network Interface / IO-Link BNI IOL IP20 Device

    5 Technical Data

    5.2 Mechanical Data

    5.3 Electical Data

    5.4 Operating- conditions

    Housing material PVC (UL94V-0)

    IO-Link Port connector block 4 poles, 3.81mm

    IO-Ports connector block 8 poles, 3.81mm

    Enclosure rating IP20

    WeightBNI IOL-309-000-K024: 60 gBNI IOL-310-000-K025: 90 g

    Dimensions see images

    Operating voltage 18...30.2 V DC, per EN 61131-2

    Ripple < 1%

    Current draw without load < 80 mA

    Operating temperature -5 0C ... 50 0C

    Storage temperature -25 0C ... 70 0C

    EMC EN 61000-4-2/3/4/5/6 - Severity level 4A/3A/4B/2A/3A

    Shock / vibration EN 60068-2-6, EN 60068-2-27EN 60068-2-29, EN 60068-2-64

  • www.balluff.com6

    3 First Steps

    3.2 Mechanical BNI IOL-309/310-000-K024/K025: Standard DIN rail mounting connections 3.3 Electrical The Sensor-Hub Modules require no separate supply voltage connection. connections Power is provided through the IO-Link interface by the host IO-Link Master. 3.4 IO-Link interface IO-Link is established by a 4 poles male.

    3.5 Connecting the Connection protection ground to FE terminal, if present. Sensor-Hub Connect the incoming IO-Link line to the Sensor Hub.

    3.6 Connecting Sensors/Actuators

    Note: For the digital sensor inputs follow the input guideline per EN 61131-2, type 2.

    Outputs may be loaded by max. 350mA.

    Pin Requirement

    24V Power supply controller, +24V, max. 1,0A

    AUX Power supply output,+24V, max. 1,6A

    0V GND, reference potential

    IOL C/Q, IO-Link Data transmission channel

    Balluff Network Interface / IO-Link BNI IOL IP20 Device

    www.balluff.com 11

    Balluff Network Interface / IO-Link BNI IOL IP20 Device

    Pin Requirements

    I/O

    Input / OutputInput: EN: 61131-2, Type: max 30V

    Output: max: 350mATotal current all output max. 1,6A.

    24V +24V, Total current max. 1A

    GND GND Reference potential

    5 Technische Data

    5.1 Dimensions

    Figure 5-1: BNI IOL-310-000-K025

    Figure 5-2: BNI IOL-309-000-K024

    2

    4

    V

    A

    U

    X

    0

    V

    I

    O

    L

    1 2 3 4 5 6 7 8

    G

    N

    D

    2

    4

    V

    I

    /

    O

  • www.balluff.com 7

    Balluff Network Interface / IO-Link BNI IOL IP20 Device

    www.balluff.com10

    4 IO-Link Interface

    4.4 Errors

    4.5 Events

    P

    a

    r

    a

    m

    e

    t

    e

    r

    D

    a

    t

    a

    Balluff Network Interface / IO-Link BNI IOL IP20 Device

    4 IO-Link Interface

    4.1 IO-Link Data BNI IOL-309-000-K024

    BNI IOL-310-000-K025

    4.2 Process Data The following process date are exchanged between IO-Link and slave:

    Input Data: Data that are transmitted from the device to the master. Output Data: Data that are transmitted from the Master to the device.

    Output Data

    Input Data

    *1) only in case of BNI IOL-310-000-K025

    Data transmission rate COM2 (38,4 kBaud)

    Frame type 2.5

    Minimal cycle time 3 ms

    Process data cycle time 3 ms, at minimal cycle time

    Vendor ID 0x0378

    Device ID 0x050901

    Byte 0 1 *1)

    Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0

    Pin 8 7 6 5 4 3 2 1 16 15 14 13 12 11 10 9

    Data transmission rate COM2 (38,4 kBaud)

    Frame type 1

    Minimal cycle time 3 ms

    Process data cycle time 12 ms, at minimal cycle time

    Vendor ID 0x0378

    Device ID 0x050902

    Byte 0 1 *1)

    Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0

    Pin 8 7 6 5 4 3 2 1 16 15 14 13 12 11 10 9

    Class / Qualifi erCode ( high + low)

    Mode Type Instance

    Appears Error AL Device Hardware Supply Supply low voltage U2 = Supply +24V

    C0 hex 30 hex 03 hex 5000 hex 0100 hex 0010 hex 0002 hex

    F3 hex 5112 hex

    Disappears Error AL Device Hardware Supply Supply low voltage U2 = Supply +24V

    80 hex 30 hex 03 hex 5000 hex 0100 hex 0010 hex 0002 hex

    B3 hex 5112 hex

    Appears Error AL Device Hardware Supply Supply periphery

    C0 hex 30 hex 03 hex 5000 hex 0100 hex 0060 hex

    F3 hex 5160 hex

    Disappears Error AL Device Hardware Supply Supply periphery

    80 hex 30 hex 03 hex 5000 hex 0100 hex 0060 hex

    B3 hex 5160 hex

    Error Code Additional Code

    Device application error: 80 hex

    11hex Index not available

    12 hex Subindex not available

    30 hex Value out of range

    IO-Link Version 1.0

    IO-Link Version 1.0

  • www.balluff.com8

    Balluff Network Interface / IO-Link BNI IOL IP20 Device

    www.balluff.com 9

    4 IO-Link Interface

    Balluff Network Interface / IO-Link BNI IOL IP20 Device

    4 IO-Link Interface

    4.3 Parameter Data / Request Data SPDU

    Object name Length

    Range

    Default valueIndex

    SubIndex

    0x10 0 Vendor name 8 Byte BALLUFF

    0x11 0 Vendor text 16 Byte www.balluff.com

    0x12 0 Product name 21 Byte

    BNI IOL-309-000-K024BNI IOL-309-000-0000BNI IOL-310-000-K025BNI IOL-310-000-0000

    0x13 0 Product ID 7 Byte Ordering code

    0x14 0 Product text 23 Byte

    BNI IOL-310-000-K025:IO Sensor/Actor Hub IP20 16Bit

    BNI IOL-309-000-K024:IO Sensor/Actor Hub IP20 8Bit

    0x16 0 Hardware Revision 3 Byte

    0x17 0 Firmware Revision 3 Byte

    P

    a

    r

    a

    m

    e

    t

    e

    r

    D

    a

    t

    a

    0x4064

    01-16

    Inversion 2 Byte0x0000 -0-FFFF

    0x0000

    0x4165

    01-16

    Confi gurationInput / Output

    2 Byte0x0000 -0-FFFF

    0x0000

    0x4266

    01-16

    In case of errorPin 1 to Pin 16

    4 Byte

    0x00000000 -

    0-FFFFFFFF

    0x00000000

    0x4468

    01-16

    Under voltage 2 Byte0x0000 -0xFFFF

    0x0000

    0x4569

    01-16

    MonitoringOutputs

    2 Byte0x0000 -0xFFFF

    0x0000

    0x4770

    01-16

    MonitoringOutputs

    2 Byte0x0000 -0xFFFF

    0x0000

    Byte 0 1 *1)

    Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0

    Pin 8 7 6 5 4 3 2 1 16 15 14 13 12 11 10 9

    Byte 0 1 *1)

    Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0

    Pin 8 7 6 5 4 3 2 1 16 15 14 13 12 11 10 9

    Byte 0 1

    Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0

    Pin 8 7 6 5 4 3 2 1

    Subindex 8 7 6 5 4 3 2 1

    0x40 Inversion (reading/writing)

    0 = not inverted1 = inverted

    0x41 Confi guration Input/Output (reading /writing)

    0 = Input1 = Output

    0x42 In case of error Pin 1 to Pin 16 (reading /writing)

    Byte 0 1 *1)

    Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0

    Pin 8 7 6 5 4 3 2 1 16 15 14 13 12 11 10 9

    Byte 0 1

    Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0

    Description - - - - - - - - - - - - - UA - UB

    Byte 2 *1) 3 *1)

    Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0

    Pin 16 15 14 13 12 11 10 9

    Subindex 16 15 14 13 12 11 10 9

    00 = Output low01 = Output high10 = Output last state11 = as 00

    0x44 Under voltage (only reading)

    0 = no under voltage1 = under voltage recognized- = not used

    0x45 Monitoring Output Actuator short circuit (only reading)

    0 = high set and high recognized1 = high set but low recognized

    0x46 Monitoring output Actuator Warning (only reading)

    0 = low set and low recognized1 = low set but high recognized

    *1) only in case of BNI IOL-310-000-K025

    Byte 0 1 *1)

    Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0

    Pin 8 7 6 5 4 3 2 1 16 15 14 13 12 11 10 9