BMI Catalog

download BMI Catalog

of 56

Transcript of BMI Catalog

  • 8/22/2019 BMI Catalog

    1/56

    INTRODUCTION

    BMI CABLES PRIVATE LIMITED is a BMI GROUP Company incorporated in 2001, and are one of

    the leading manufacturers ofElastomeric (Rubber), PVC, XLPE Power & Control Cables, Mining,

    Telecommunication Cables including FR, FRLS & Low Halogen Cables under the brand name of"BMIC" at its modern plant at Bhiwadi, Alwar (Rajasthan), 80 kms from Delhi.

    BMI Cable's plant is accredited with ISO 9001 : 2000 certification. This includes well established

    production lines, modern quality control facilities, up-to-date technical assistance wing and well planned

    plant utility and offsite facilities. This is supported by a team of dedicated, experienced and well qualified

    managerial, engineering and other staff. The Company always enjoyed an excellent industrial relations.

    It has now an integrated cable manufacturing plant with facilities right from wire drawing to packing of the

    finished products under one roof, and produces the cables of high quality as per ISI, British and various

    other International Standards like IEC, ASTM, JIS, VDE, DIN. It has also designed, manufactured,

    tested and supplied wires & cables meeting special requirements of various customers.

    The utilities and offsite facil ities cover Water Storage, Steam Generation, Electrical Transformers, Standby

    D.G. Set, Air Compressors and Material handling facil ities. The manufacturing facilities are supported with a

    workshop for ensuring adequate maintenance and upkeep of machineries. The testing and quality control

    section offers facilities to carry out all Routine, Acceptance and Type tests as per Indian as well as

    international standards.

    Excellent quality of cables is maintained by strict quality control at every stage of manufacturing and by virtue

    of very stringent tests conducted as per the relevant specifications at our well equipped laboratory under

    the supervision of qualified engineers and experts, BMI Cables has implemented an extensive quality

    assurance and quality control programme. It's Testing Laboratory is fully equipped with most

    sophisticated and imported instruments, engineersare busy checking, testing and ensuring quality of

    inputs including raw materials as well as the finished products at every stage. Our products have been

    successfully type tested in -House and other government testing laboratories.

    BMI Cables has a team of highly trained technical staff who could advise you regarding suitability of cables

    for special applications and on laying conditions for optimum economy and also advise you regarding the

    accessories such as jointing, termination etc. Today, BMI Cables serves Power, Cement, Steel Plant,

    Telecommunication & Fertilizer Companies as well as wide range of Contractors & Industrial

    users.

    Looking to the need of unfailing and dependable power transmission and distribution to sustain the tempo of

    industrialisation, BMI Cables has undertaken extensive modernisation, upgradation and expansion

    programme to enlarge its product range to L T & HT Elastomeric (Rubber)/ PVC/XLPE Cables and provides

    improved technical products and services.

    Lastly, in line with the Corporate objectives of Quality Control, Perfection and

    Professionalism, BMI CABLES PVT. LTD. has emerged as a force to reckon with.

    1

  • 8/22/2019 BMI Catalog

    2/56 2

  • 8/22/2019 BMI Catalog

    3/56

    Our Product Range

    Elastomeric (Rubber)

    Elastomeric (Rubber) Insulated Cables as per IS : 9968 (PART-1):1988 & IS : 9968 (PART-2):2002

    Welding Cables as per IS : 9857:1990

    Trailing & Composite Cables as per IS : 9968 (PART-1) & (PART-2)

    Silicon Cables as per IS : 9968 (PART-1) : 1988

    Furnace & High Temperature Cables

    Uniprene Cables

    PVC/XLPE

    PVC Insulated Wires & Cables as per IS : 694:1990

    PVC Insulated Power & Control Cables as per IS : 1554 (PART-1) & (PART-2)

    XLPE Insulated Power & Control Cables as per IS : 7098 (PART-1) & (PART-2)

    FRLS/Fire Survival Cables as per IS : 1554

    Instrumentation Cables both screened/shielded and armoured

    Nyvin Cables as per BS : G: 177 March 1961

    3

  • 8/22/2019 BMI Catalog

    4/56

  • 8/22/2019 BMI Catalog

    5/56

    ELASTOMERIC

    (RUBBER) CABLES

    ELASTOMERIC(RUBBER) CABLESELASTOMERIC(RUBBER) CABLES

  • 8/22/2019 BMI Catalog

    6/56

  • 8/22/2019 BMI Catalog

    7/56

    ELASTOMERIC (RUBBER) CABLES

    There are various types of compounds according to the grades and properties as per IS:6380 such as general purpose,heat resisting and high temperature insulation. The elastomeric cables are suitable for use where the combination ofambient temperature and temperature-rise due to load remains stable up to the following limits in conductors.

    Elastomeric compounds for insulating and sheathing of cables are formulated to meet the requirement of IS : 6380, BS6899, IEC 60502 and other international specification.

    GENERAL CONSTRUCTION OF RUBBER CABLE {as per IS 9968 (Part I)}/1988

    Conductor - Annealed tinned Copper conductors Solid (Class I), Stranded (Class 2),flexible (Class 5) complying with the requirement of IS 8130-1984.

    Separator Tape - A polyester (Melinex) tape to be applied over the conductor.

    Insulation - General service elastomer type IE1 of IS 6380-1984Heat Resisting insulation Type IE2 & IE3 of IS 6380-1984Silicone Rubber Insulation Type IE5 of IS : 6380-1984

    Core Identification - The cores are identified either by colours or by numbers as per following table.

    Elastomer (Rubber) is an insulating material with high dielectric strength having a decent property of flexibility. Theelastomeric cables are suitable for applications in electric iron leads, reeling-unreeling application in mining, heater leads,elevators, cranes and other high dielectric and flexible applications. The BMI Cables are manufactures wire & cables toIS 9968 (Part-1)/1988, IS 14494 & IS 9857/1990 for welding cables.

    BMI CABLES PRIVATE LIMITED is one of the leading manufacturers of varieties of Elastomeric Cables made ofNatural and various types of Synthetic rubber compounds. The compounds based on EPR, CSP, NBR-PVC, EVA, Siliconeare made in the most modernised plant by highly skilled hands to suit the specific operational regiments, continuous R & Dand upgraded production technology are the main features of Elastomeric Cables Division at BMI. The cables aremanufactured in compliance with every National and International Standards. The Design Engineers at BMI renders everyassistance to the customer in designing a cable for any critical application.? Elasomeric cables and flexible cords for power and lighting.

    ? Welding cables (General purpose and HOFR types).

    ? Ship wiring cables and cables for submerged connections.

    ? Railways locomotives and coach wiring cables.

    ? Cables for engineering and chemical industries.

    ? Mining cables- Flexible Trailing, Coal Cutter, Pliable armoured and Land Line Cables upto 11kv

    ? Cables for wind electric generators (Wind mill projects).

    ? Silicone rubber insulated high temperature cable.

    ? Flame retardent, fire resistant, LFH and FS cables.

    S. No. No. of Cores Colours of Cores Number Printing

    1. Single Red, Yellow, Black, white or blue

    2. Twin Red and Black 1, 23. Three Red, Black, Green 1, 2, 3

    4. Four Red, Yellow, Blue, Green 1, 2, 3, 4

    5. Five Red, Yellow, Blue, Black & Green 1, 2, 3, 4, 5

    Tape (Optional) - A proofed tape/PETP/RPCT/Plastic Tape over insulation is provided.Braiding - As required in different cables braiding with textile/fibre glass yarn is provided.Fillers - Natural or synthetic fibre or elastomer suitable for the operating temperature and

    compatible with the insulating material.Sheath - General service sheath Type SE1&SE2 of IS : 6380-1984

    Heavy Duty / Heat Resisting Sheath Type SE3 & SE4 of IS : 6380-1984

    7

  • 8/22/2019 BMI Catalog

    8/56

    Material Max. Cond. Temp. Max. Cond. Min. Workingfor continuous temp. for short Temp.

    operation Deg C. circuit Deg C. Deg C

    Natural Rubber (VIR & TRS) 60 200 -55

    Ethylene Propylene Rubber (EPR) 90 250 -50Polychloroprene (PCP) 70 200 -40

    Chlorosulphonated Polyethylene (CSP) 90 200 -35

    Silicone Rubber 150/180 350 -55

    HR Natural Rubber (HR VIR) 75 200 -55

    Styrene Butadiene Rubber (SBR) 60 200 -55

    Butyl Rubber 85 220 -50

    Elastomeric, Single Core, Two Core, Three Core, Four Core Flexible Copper Conductor

    General Purpose/HOFR/EPR/CSP/Silicon Insulated & Sheath Flexible Cables ISI Marked

    Nominal Cross NominalSectional area Thickness of Nominal Sheath Thicknessof Conductor Insulation

    (Per Core) Single Core Two Core Three Core Four Core2

    mm mm mm mm mm mm

    0.5 1.0 1.0 1.0 1.0 1.0

    0.75 1.0 1.0 1.0 1.0 1.1

    1.0 1.0 1.0 1.0 1.0 1.1

    1.5 1.0 1.0 1.0 1.1 1.1

    2.5 1.0 1.0 1.1 1.1 1.1

    4.0 1.0 1.0 1.2 2.0 1.2

    6.0 1.2 1.6 2.0 2.1 2.5

    10 1.2 1.8 2.4 2.5 2.7

    16 1.2 1.9 2.5 2.7 2.925 1.4 2.0 3.2 3.3 3.4

    35 1.4 2.2 3.3 3.4 3.5

    50 1.6 2.4 3.5 3.6 3.7

    70 1.6 2.6 3.6 3.7 3.9

    95 1.8 2.8 3.8 4.0 4.1

    120 1.8 3.0 4.0 4.1 4.3

    150 2.0 3.2 4.2 4.3 4.5

    185 2.2 3.4 4.3 4.5 4.8

    240 2.4 3.5 4.6 4.8 5.1

    300 2.6 3.5 4.9 5.1 5.4

    400 2.8 3.8 5.2 5.4 5.8

    500 3.0 4.0 - - -

    630 3.0 4.1 - - -

    Construction :Conductor (a) Tinned Copper conductor as per IS : 8130Insulation (i) General Service Elastomeric Type IE1as per IS : 6380

    (ii) Heat Resisting Elastomeric Type IE2 as per IS : 6380(iii) Tape Optional

    Filler 2-3 and 4 core laid upSheath General Service and Heat Resisting

    Sheath as per IS: 6380

    Annealed

    Working Temperature of Commonly used Elastomeric Insulating and Sheathing Materials

    InsulationConductor

    FillerSheath

    8

  • 8/22/2019 BMI Catalog

    9/56

    Current Ratings and Associated Voltage Drop for Flexible Cords Insulated

    with PVC or VIR or Butyl Rubber / EPR or Silicone Rubber.

    MAIN APPLICATION : Internal Wiring, Mains Supply Connection/Extension leads to Appliances.

    Nominal CrossSectional Area of Conductor

    2(mm )

    Nominal No. and Diameterof Wires(Nos/mm)

    Approx. over all Dia ofConductor(mm)

    Max Allowable Resistence at 20C for tinned wires

    (0hms/km)Current rating D.C. inSingle or Three phase

    (A)

    Approx. voltage Drop Per10 meter run

    (Volts)

    Max. permissible weightsupported by twin flexible

    cords (Kg)

    Single CoreMulti Core

    0.5 16/0.20 0.93 38.20 40.10 3 3.30 1.50

    0.75 24/0.20 1.14 25.40 26.70 6 3.70 2.50

    1.0 32/0.20 1.32 19.10 20.00 10 4.50 4.50

    1.5 30/0.25 1.60 13.0 13.70 15 4.00 4.50

    2.5 50/0.25 2.00 7.82 8.21 20 2.90 4.50

    4.0 56/0.30 2.60 4.85 5.09 25 2.60 4.50

    Note : (1) Current ratings are for cables to IS 694 Part-1 (PVC) and IS 9968 Part-1 (Rubber) or B.S. 6500.

    (2) All the above ratings are based on an ambient temp. of 30C and are in accordance with IEE regulation.They are application to cords laid straight and not in coils.

    (3) Rating factors for ambient temperature (applicable to PVC or VIR)

    Ambient temperature (C) 30 35 40 45 50 55Rating Factor 1.00 0.96 0.92 0.87 0.71 0.50

    (4) For flexible cords insulated with EPR / Butyl (85C) or Silicone rubber (150C) and heat resistance.sheathe the rating factor are.

    (a) EPR / Butyl RubberAmbient Temperature (C) 30.50 55 60 65 70Rating Factor 1.0 0.96 0.63 0.67 0.47

    (b) Silicone RubberAmbient Temperature (C) 35.120 125 130 135 140Rating Factor 1.0 0.96 0.85 0.74 0.60

    Nominalcross

    SectionalArea of

    Conductor

    NominalNo. andDiameterof Wire

    Approx.Over AllDia of

    Conductor

    Max. Allowable Resistenceat 20C for Tinned Wires

    Current Rating VIR insulated Butyl/EPR/Silicone Rubber Insulated Voltage Drop volts / Km. / Amp.

    VIR Insulated Butyl/EPR/S il icone Rubber Insulated VIR Insulated Butyl/EPR/S il icone Rubber Insulated

    Single Core Multi Core DC or SinglePhase AC

    ThreePhase

    DC or Single PhaseAC

    ThreePhase

    DC SinglePhase

    ThreePhase AC

    DC SinglePhase

    ThreePhase AC

    2(mm ) (No./mm)

    2(mm ) (ohms/Km) (ohms/Km) (A) (A) (A) (A) (mV) (mV) (mV) (mV) (mV) (mV)

    4 56/0.30 2.60 4.85 5.09 33 28 40 31 11 11 9.7 13 13 11.5

    6 84/0.30 3.30 3.23 3.39 42 36 51 44 7.3 7.3 6.6 7.9 7.9 7.2

    10 80/0.40 4.20 1.85 1.96 57 49 70 60 4.2 4.2 3.8 4.6 4.6 4.2

    16 126/0.40 5.70 1.18 1.24 76 66 93 81 2.7 2.7 2.4 2.9 2.9 2.6

    25 196/0.40 7.10 0.757 0.796 100 85 120 105 1.7 1.7 1.6 1.9 1.9 1.7

    35 276/0.40 8.50 0.538 0.565 120 100 145 125 1.2 1.24 1.10 1.3 1.3 1.2

    50 396/0.40 10.30 0.375 0.393 150 130 185 160 0.85 0.88 0.79 0.93 0.96 0.85

    70 360/0.50 12.40 0.264 0.277 180 160 225 195 0.80 0.64 0.56 0.65 0.68 0.61

    95 475/0.50 14.50 0.200 0.210 220 190 270 235 0.45 0.50 0.43 0.49 0.53 0.47

    120 608/0.50 16.00 0.156 0.164 250 220 306 270 0.36 0.41 0.35 0.38 0.43 0.38

    150 756/0.50 18.00 0.126 0.132 290 250 355 306 0.29 0.34 0.29 0.31 0.36 0.31

    185 925/0.50 20.00 0.103 0.108 330 285 405 350 0.23 0.30 0.25 0.26 0.32 0.27

    240 1221/0.50 23.00 0.078 0.0817 390 330 465 405 0.18 0.25 0.21 0.20 0.27 0.22

    300 1525/0.50 26.00 0.0623 0.0654 435 385 530 470 0.14 0.23 0.18 0.16 0.24 0.199

    400 2013/0.60 30.50 0.0472 0.0400 520 630 0.11 0.21 0.12 0.21

    500 1769/0.60 33.00 0.0373 0.0391 590 720 0.09 0.19 0.10 0.20

    630 2257/0.60 37.00 0.0292 0.0306 680 830 0.07 0.18 0.06 0.19

    Current Ratings and Associated Voltage Drop for Flexible Cables Insulated with VIR or Butyl Rubber/

    EPR or Silicone Rubber Main Applications : Services or Mains Supply where flexibility is required.

    9

  • 8/22/2019 BMI Catalog

    10/56

    Note : (1) Current ratings are for cables to IS 9968 (PI-1) or BS 6007

    (2) Rating for one twin cable or two angle cores bunched.

    (3) Rating for three four of five core cable

    (4) The rating as given above are for a tangle circuit and are based on an ambient temp. Of 30C

    Rating factor for ambient temperature .Ambient Temperature (C) 35 40 45 50 55 60 70Factor for VIR insulation (C) 0.91 0.82 0.71 0.57 0.41 - -

    Factor for Butyl/EPR insulation (85C) 0.93 0.86 0.80 0.72 0.63 0.54 0.31

    Factor for Silicon Rubber Insulation (150C) 1.0 0.94 0.88 0.82 0.71 0.56 0.39

    Nominal CrossSelection Area of

    Conductor

    Max Allowable Resistenceat 20C for tinnedwires Multi Core

    CURRENT RATINGS UP TO 10 kv GRADE CURRENT RATINGS ABOVED TO 10 kv GRADE

    EI (VIR)Insulated

    E2 (EPR)Insulated

    VIRInsulated

    EPRInsulated

    2(mm ) (ohms/km) (A) (A) (A) (A)

    2.5 0.21 25 32 - -

    4 5.09 34 43 - -

    6 3.39 44 56 - -

    10 1.95 60 78 - -

    16 1.24 80 104 85 110

    25 0.795 107 138 113 146

    35 0.565 133 171 141 181

    50 0.393 165 213 175 226

    70 0.277 204 263 216 279

    95 0.210 245 317 260 336

    120 0.164 287 370 304 391

    150 0.132 329 425 349 450

    185 0.108 375 485 398 514

    Current Carrying Capacities for Multi Core Flexible Trailing Cables

    Armoured / Unarmoured insulated with either VIR or EPR all Voltage Grades

    Note : (1) This table covers current ratings of flexible trailing cable armoured/unarmoured conforming to IS: 9968 Part1&2 IS:14494, VDE 0250 NCB and other equivalent international specifications.

    (2) The ratings as given above are based on ambient temp. 30C for higher temp. refer to the following table ofcorrection factors.

    (3) Rating factor for "MONOSPIRAL" reeling drum winding duty is 0.85

    (4) For reeling-unreeling operation rating factors are as follows :No. of times 1 2 3 4Derating Factor 0.76 0.58 0.47 0.40

    Rating Factors for Ambient Temperature

    Ambient Temperature (C) 25 30 35 40 45 50 55 60 70

    Factor for VIR Insulation 1.08 1.0 0.91 0.82 0.71 0.58 0.41

    Factor for EPR Insulation 1.05 1.0 0.95 0.90 0.85 0.80 0.74 0.67 0.52

    Ambient Temperature (C) 35-85 90 100 110 120 130 140

    Factor for SILICON Insulation 1.0 0.96 0.88 0.78 0.68 0.55 0.39

    10

  • 8/22/2019 BMI Catalog

    11/56

    Elastomeric : Silicon Rubber insulated single core, three-core and

    four core glass brided and varnished cables & cords. Conforming to

    IS : 9968 Pt.1/88

    Nominal CrossSectional Area of

    Conductor

    Nominal Thickness of Insulation

    Cable for fixed

    Wiring

    Flexible Cables

    and Cordssq.mm mm mm

    0.5 0.5 1.0

    0.75 0.75 1.0

    1.0 1.0 1.0

    1.5 1.5 1.0

    2.5 2.5 1.0

    4.0 4.0 1.0

    6.0 6.0 1.0

    10 10 1.20

    16 16 1.20

    25 25 1.4035 35 1.40

    50 50 1.60

    ELASTOMER FLEXIBLE CABLES(As per IS : 9968/Pt-II/02)

    Conductor SIZE OF GROUNDING CONDUCTOR SIZES (Sq.mm)

    Power conductor 16 25 35 50 70 95 120 150 185 240 300

    Grounding conductor 16 16 16 25 35 50 70 70 95 120 150

    ConductorSize

    Insulation Thickness1.9/3.3 and3.3/3.3 kV

    3.8/6.6 kV 6.6/6.6 and6.35/11 kV

    11/11 kV12.7/22 kV

    (Sq.mm) (mm) (mm) (mm) (mm)

    16 2.2 3.0 4.0 6.0

    25 2.2 3.0 4.0 6.0

    35 2.2 3.0 4.0 6.0

    50 2.2 3.0 4.0 6.0

    70 2.2 3.0 4.0 6.0

    95 2.4 3.0 4.0 6.0

    120 2.4 3.0 4.0 6.0

    150 2.4 3.0 4.0 6.0

    185 2.4 3.0 4.0 6.0

    Diameter Under Inner Sheath Thickness of SheathAbove Up to & Including Inner Outer

    (mm) (mm) (mm) (mm)

    10 1.0 1.6

    10 15 1.2 2.0

    15 20 1.4 2.2

    20 25 1.6 2.5

    25 30 1.8 3.0

    30 40 2.0 3.5

    40 50 2.4 4.0

    50 60 2.8 4.5

    60 70 3.2 5.0

    70 80 3.6 5.5

    80 4.0 6.0

    INSULATION THICKNESS THICKNESS OF SHEATHS

    GENERAL APPLICATIONS OFELASTOMERIC (RUBBER) CABLES

    1. Main Application of Elastomeric Cable where flexibility isinvolved, like reeling un-reeling trailing festooning purpose.

    2. Lifts, Cranes, Conveyors & other mobile machine used in Steel

    Plants, Cement Plants, Sugar Mills etc.

    3. Flexible cords upto 4.0 Sq.mm. (Domestic type) for the connectionof Electric Iron, Fans, Motors, Coolers etc.

    4. Flexible cords upto 4.0 Sq.mm. (Workshop type) for the connectionof Industrial equipments.

    5. Welding cable.

    6. Earthing cables.

    7. Wind Mil l Cables.

    8. Ship Wiring & Railways wiring.

    9. Coal mines cable for mobile production machineU/G application.

    10. High temperature cable with Silicon Rubber Insulation.

    ELASTOMERIC INSULATED FLEXIBLE CABLES FOR USE IN MINES(AS PER IS : 14494/98)

    SIZE OF POWER, EARTHING & PILOT CONDUCTORS

    Power Conductor Sq.mm 2.5 4 6 10 16 25 35 50 70 95 120 150 185

    EarthingConductor

    Type-A Sq.mm 2.5 4 6 10 16 16 16 25 35 50 70 70 95

    Type-B Sq.mm 2.5 4 6 10 16 25 35 50 70 95 120 150 185

    Pilot Conductor Sq.mm 2.5 4 6 10 16 16 16 25 35 50 70 70 95

    11

  • 8/22/2019 BMI Catalog

    12/56

    INSULATION THICKNESS

    Nom. Area of conductor(Sq. mm)

    Nom. Thickness of Insulation For Power Cores

    1.1 kV(mm)

    3.3 kV(mm)

    3.8/6.6 kV(mm)

    6.35/11 kV(mm)

    2.5 1.0

    4 1.0

    6 1.0

    10 1.2

    16 1.2 2.2 3.0 4.0

    25 1.4 2.2 3.0 4.0

    35 1.4 2.2 3.0 4.0

    50 1.6 2.2 3.0 4.0

    70 1.6 2.2 3.0 4.0

    95 1.8 2.4 3.0 4.0

    120 1.8 2.4 3.0 4.0

    150 2.0 2.4 3.0 4.0

    185 2.2 2.4 3.0 4.0

    THICKNESS OF INNER & OUTER SHEATH

    (except for Collective Metallic Screened and

    Pliable Wire Armoured Cables)

    Calculated Dia. UnderInner Sheath

    Thickness of Sheath

    Over(mm)

    Up to and Including(mm)

    Inner Min.(mm)

    Outer Nom.(mm)

    10 1.4 2.0

    10 15 1.6 2.415 20 1.8 2.6

    20 25 2.0 2.8

    25 30 2.2 3.0

    30 40 2.4 3.2

    40 50 2.8 3.6

    50 60 3.2 4.0

    60 70 3.6 4.5

    70 80 4.0 5.0

    80 4.4 5.5

    THICKNESS OF INNER & OUTER SHEATH

    (for Collective Metallic Screened and

    Pliable Wire Armoured Cables)

    Calculated Dia. Under Inner Sheath for choosingthickness of inner sheath & calculated dia. underouter sheath for choosing thickness of outer sheath

    Thickness of Sheath

    Over(mm)

    Up to and Including(mm)

    Inner Min.(mm)

    Outer Nom.(mm)

    10 1.6 2.5

    10 15 1.8 2.8

    15 20 2.0 3.2

    20 25 2.2 3.6

    25 30 2.4 4.0

    30 40 2.6 4.5

    40 50 3.0 5.0

    50 60 3.5 5.7

    60 70 4.0 6.4

    70 80 4.5 7.1

    80 90 5.0 7.8

    90 100 5.5 8.5

    100 6.0 9.0

    Note : 1. The nominal thickness of insulation for pilot core(s) shall be 1.0mm. However, higher thickness whenever required to build up thediameter is permitted.

    2. The thickness of covering on earth conductor(s) shall be suitably selected for covered earth conductor(s).

    Diameter Under Armour Size of ArmourStrand

    (No.s / mm)

    Diameter ofBraiding Wire

    (mm)Above(mm)

    Up to and including(mm)

    25 7/0.45 0.30

    25 40 7/0.71 0.45

    40 60 7/0.90 0.45

    60 7/1.25 0.45

    DIMENSION OF PLIABLE WIRE ARMOUR AND BRAIDING WIRE

    (As per IS : 9968/Pt -II/81 & IS : 14494/98)

    Why "BMI" cables are better?1. High current carrying capacity due to low conductor resistance.2. High insulation resistance.3. Small bending radius.4. Long service life.5. Good Ageing characteristics.6. Heat resisting, Oil resisting & Flame retardent property.7. Ozone resistant.8. Extra flesibility due to super annealed copper wire & good

    elasticity of compound.9. Excellent mechanical features of the insulation improves the

    protection against external effects.10. Packing material suitable for handling.11. Fast delivery period for any cable.

    12

  • 8/22/2019 BMI Catalog

    13/56

    SILICONE CABLES

    Silicone rubber has excellent electrical properties and high thermal resistance. It allows conductor temperaturerating of 150C for continuous operation and 250C under emergency overload or short circuits continuity even infire because silicone rubber burns in to an insulating ash. It is resistant to moisture ozone radiation and chemicals.Being elastomeric in nature it is flexible and flexibility is retained over wide range of temperature. (-55c to 250c)

    1. Specialities? High temperature operation? Excellent electrical properties? Moisture resistant? Long Service Life? Light weight? Flexibility over wide range of temperatures? Resistance to ozone and sunlight.

    2. Application :? Airport lighting or other High Mast Lighting units. Extraction Plant? Aircrafts and Missiles High temperature metallurgical plants, Material

    Handling Equipment? Blast Furnaces Machine Tools? Boiler Nuclear Power, Thermal Power Stations Blast Furnaces generator Printing Presses? Coke Ovens Steel Mills? Construction Equipment Ships? Driers Textile Machinery? EOT Crane Turbines? Electirc Furnaces

    3. Construction :(A)Single Core Cable : Annealed tinned copper or aluminium conductor, insulated with silicone rubber and finally

    fibre glass braided and varnished.(B) Multi Core Cable : Cores colour coded laid up and finally fibre glass braided and varnished or Asbestos braided.

    Cables can also be supplied with other protective sheaths such as Silicone, Neoprene and CSP,or with braid screen or steel wire or strip armour.

    Voltage Grade : Usually 1000 V/3300/6600/13800V.Size Range : Upto 630 sq.mm.Specifications : Generally to BS : 6360/BS6195, IEC 245-1, IS : 6380/IS : 9968

    13

  • 8/22/2019 BMI Catalog

    14/56

    At present Copper and Aluminium welding cables are covered under IS : 9857-1990. The earlier IS : 434, covered only VIR covering.Whereas, the present specification covers Welding Cables under two categories.

    1. Cable with General Purpose Rubber compound covering (GPR)2. Cable with Heat Resistant, Oil Resistant , Fire Retardant compound covering (HOFR).

    Construction

    (a) Conductor :(I) Copper Conductor : The conductor shall be composed of plain or tinned annealed high conductivity copper wired

    complying with IS : 8130. The conductor formation shall be according to class 6 (Table 4) of IS : 8130.

    (ii) Aluminium Conductor : The conductor shall be composed of Aluminium wires complying with IS : 8130. The conductorformation shall be according to Table 5 of IS : 8130.

    (b) Separator :The separator shall be of polyester tape/dry paper, or any other suitable material. The conductor shall be covered with aseparator. The separator tape shall applied on conductor to give complete coverage to conductor.

    (c) Covering : GPR/HOFRThe general purpose rubber compound shall comply with requirements of type SE1 to IS : 6380. The heat resistant normal dutyHeat Resistant, Oil Resistant , Fire Retardant (HOFR) compound covering compound shall comply with the requirement of TypeSE 3 to IS : 6380. The covering shall consist of one of the following applied over the conductor and separator.

    (a) A layer of general purpose normal duty rubber compound.or

    (b) A layer of Heat Resistant, Oil Resistant , Fire Retardant (HOFR) compound covering normal duty.

    WELDING CABLES

    *60C & 85C Class - The maximum conductor temperature attained for the duty cycles specified for the welding cables.*DC : Duty Cycle, GP : General Purpose Type, HOFR : Heat Resistant, Oil Resistant , Fire Retardant Type.

    Table

    Multistrand FlexibleCopper Conductor

    Compound CoveringSE1/SE3

    Polyester/Melinex Tape

    Multistrand FlexibleAluminium Conductor

    Compound CoveringSE1/SE3

    Polyester/Melinex Tape

    14

    Equivalent rating toIS : 434 at20% DC

    Converted at40C ambient air

    temperature(Amps.)

    New Sectionto IS : 9857

    size

    MaximumDiameterof Wire inthe bunch

    New Rating at 40C ambient GPTypw (60C Class*)

    New Rating at 40C ambientHOFR type (85C class) Theread

    ofcovering

    Rating at20% DC**

    Rating at60% DC**

    Rating at100% DC**

    Rating at20% DC**

    Rating at60% DC**

    Rating at100% DC**

    GP HOFR (Sq.mm) (mm) (Amps.) (Amps.) (Amps.) (Amps.) (Amps.) (Amps.) (mm)

    Copper Conductor

    150 16 0.21 179 103 80 261 151 117 2.0

    150 230 25 0.21 230 133 103 351 203 157 2.0

    230 400 35 0.21 288 166 129 438 253 196 2.0

    400 600 50 0.31 373 215 167 550 320 248 2.2

    600 800 70 0.31 458 264 205 691 390 309 2.4800 1000 95 0.31 561 324 251 836 482 374 2.6

    Aluminium Conductor

    150 25 0.31 179 103 80 273 157 122 2.0

    150 230 35 0.31 230 133 103 340 196 152 2.0

    230 400 50 0.31 288 166 129 438 253 196 2.2

    400 600 70 0.31 358 206 160 534 308 239 2.4

    600 800 95 0.31 434 250 194 651 375 291 2.6

    800 1000 120 0.31 510 294 223 758 437 339 2.8

  • 8/22/2019 BMI Catalog

    15/56

    PVC/XLPE POWER &

    CONTROL CABLES

    PVC/XLPE POWER &CONTROL CABLESPVC/XLPE POWER &

    CONTROL CABLES

  • 8/22/2019 BMI Catalog

    16/56

  • 8/22/2019 BMI Catalog

    17/56

    2.5 1 1.2 1.4 1.24 10.5 140 .90 1.80 8.0 110 7.41 8.89 0.43 35 30 31 29 32 27

    4 1 1.3 1.4 1.24 10.9 173 1.00 1.80 8.6 114 4.61 5.52 0.158 0.47 46 39 42 38 43 35

    6 1 1.3 1.4 1.24 11.4 204 1.00 1.80 9.1 142 3.08 3.69 0.148 0.56 57 49 54 48 54 44

    10 6 1.3 1.4 1.24 12.3 259 1.00 1.80 10.1 190 1.83 2.19 0.138 0.67 75 65 72 64 72 60

    16 6 1.3 1.4 1.24 13.1 320 1.00 1.80 10.8 248 1.15 1.38 0.128 0.81 94 85 92 83 92 82

    25 6 1.5 1.4 1.24 14.7 440 1.20 1.80 12.4 357 0.727 0.87 0.120 0.87 125 110 120 110 125 110

    35 6 1.5 1.4 1.24 15.7 548 1.20 1.80 13.4 458 0.524 0.627 0.114 1.00 150 135 140 125 155 130

    50 6 1.7 1.4 1.24 17.2 696 1.40 1.80 14.9 595 0.387 0.463 0.110 1.03 180 155 165 150 190 165

    70 12 1.7 1.4 1.40 19.1 930 1.40 1.80 16.5 805 0.268 0.321 0.103 1.21 220 190 200 175 235 205

    95 15 1.9 1.6 1.40 21.6 1243 1.60 1.80 18.6 1081 0.193 0.231 0.101 1.27 265 220 230 200 275 245

    120 18 1.9 1.6 1.40 23.7 1515 1.60 2.00 21.1 1332 0.153 0.184 0.096 1.42 300 250 255 220 310 280

    150 18 2.1 1.6 1.40 24.8 1802 1.80 2.00 22.2 1630 0.124 0.149 0.094 1.42 340 280 280 245 345 320

    185 30 2.3 1.6 1.40 27.1 2198 2.00 2.00 24.5 2013 0.0991 0.12 0.092 1.44 380 305 305 260 390 370

    240 34 2.5 1.6 1.56 30.2 2822 2.20 2.00 27.3 2592 0.0754 0.091 0.090 1.53 420 345 340 285 445 425

    300 34 2.8 2.0 1.56 33.7 3542 2.40 2.00 29.8 3202 0.0601 0.074 0.088 1.56 465 375 370 310 500 475

    400 53 3.0 2.0 1.56 37.1 4412 2.60 2.20 33.6 4070 0.0470 0.059 0.088 1.56 500 400 405 335 570 550

    500 53 3.4 2.0 1.72 41.2 5585 3.00 2.20 37.4 5175 0.0366 0.046 0.087 1.57 540 425 430 355 610 590

    630 53 3.9 2.0 1.88 46.2 7138 3.40 2.40 42.2 6664 0.0283 0.037 0.086 1.57 590 470 465 375 680 660

    800 53 3.9 2.0 1.88 52.0 9000 3.40 2.40 48.0 8248 0.0221 0.031 0.083 1.75 664 530 523 425 766 743

    1000 53 4.0 2.5 2.04 57.3 1 1167 3.40 2.60 52.2 10419 0.0176 0.027 0.082 1.94 733 585 579 467 856 830

    1.5 1 1.1 1.4 1.24 10.1 120 .80 1.80 7.1 72 12.1 14.52 0.38 25 22 23 21 24 20

    Unarmoured1. Copper2. Insulation - PVC3. Outer Sheath - PVC

    Conductor -

    Armoured4.5. Insulation - PVC6. Armouring - Wire (Non Magnetic)7. Outer Sheath - PVC

    Conductor - Copper

    4567

    123Unarmoured

    Armoured

    ARMOURED UNARMOURED CURRENT RATINGS

    Cross Min. No. Thickness Nominal Min. Overall Approx. Thickness Nom. Overall Approx. Max. D.C. Max. A.C. Approx. Approx. Direct in Ground In Duct In Air

    sectional of Wires of PVC Dimensions Thickness Diameter Net Wt. of insulation Dimension Diameter Net Wt. Resistance Resistance Reactance Capacitance 2 3 2 3 2 3area of insulation of Armour of PVC Outer (Approx.) of Cable (Nom.) of Arour (Approx.) of Cable at 20C at 70C at 50 Hz Cables Cables Cables Cables Cables Cables

    conductor (Nom.) Wire Sheath Wire

    (mm) (mm) (mm) (mm) (mm) ( Kg/Km) (mm) (mm) (mm) (Kg/Km) Ohms/Km Ohs/Km Ohms/Km mfd/Km Amps A mps Amps Amps Amps Amps

    TECHNICAL DATA

    1 CORE COPPER PVC AMROURED & UNARMOURED POWER CABLES

    17

  • 8/22/2019 BMI Catalog

    18/56

    TECHNICAL DATA

    1 CORE ALUMINIUM PVC AMROURED & UNARMOURED POWER CABLES

    1.5 1 1.1 1.4 1.24 9.5 110 .80 1.8 7.2 60 18.1 2172 0.38 0.157 0.47 221 17 19 17 18 15

    2.5 1 1.2 1.4 1.24 10.1 125 .90 1.8 8.0 72 12.1 14.52 0.43 0.145 0.52 28 24 25 24 25 21

    4 1 1.3 1.4 1.24 10.9 148 1.0 1.8 8.60 89 7.4100 8.8900 0.158 0.47 0.137 0.58 36 31 33 30 32 27

    6 1 1.3 1.4 1.24 11.4 165 1.0 1.8 9.10 103 4.6100 5.5300 0.148 056 0.127 0.68 44 39 42 37 41 35

    10 1 1.3 1.4 1.24 12.3 196 1.0 1.8 10.10 127 3.0800 3.7000 0.138 0.67 0.118 0.83 59 51 56 51 56 47

    16 6 1.3 1.4 1.24 13.1 225 1.0 1.8 10.80 152 1.9100 2.2900 0.128 0.81 0.110 1.01 75 66 71 65 72 64

    25 6 1.5 1.4 1.24 14.7 287 1.2 1.8 12.40 204 1.2000 1.4400 0.120 0.87 0.105 1.05 97 86 93 84 99 84

    35 6 1.5 1.4 1.24 15.7 334 1.2 1.8 13.40 244 0 .8680 1.0400 0.114 1.00 0.100 1.22 120 100 110 100 120 1 05

    50 6 1.7 1.4 1.24 17.2 411 1.4 1.8 14.90 310 0 .6410 0.7700 0.110 1.03 0.098 1.22 145 120 130 115 150 1 30

    70 12 1.7 1.4 1.40 19.1 513 1.4 1.8 16.50 388 0.4430 0.5300 0.103 1.21 0.091 1.43 175 140 155 135 185 155

    95 15 1.9 1.6 1.40 21.6 662 1.6 1.8 18.60 501 0.3200 0.3800 0.101 1.27 0.088 1.47 210 175 195 155 215 190120 15 1.9 1.6 1.40 23.7 784 1.6 2.0 21.10 621 0.2530 0.3000 0.096 1.42 0.086 1.62 240 195 200 170 240 220

    150 15 2.1 1.6 1.40 24.8 898 1.8 2.0 22.20 726 0.2060 0.2500 0.094 1.42 0.085 1.62 270 220 220 190 270 250

    185 30 2.3 1.6 1.40 27.1 1069 2.0 2.0 24.50 884 0.1640 0.2000 0.092 1.44 0.084 1.62 305 240 240 210 305 290

    240 30 2.5 1.6 1.56 30.2 1337 2.2 2.0 27.30 1 106 0.1250 0.1500 0.090 1.53 0.082 1.72 335 270 270 225 350 335

    300 30 2.8 2.0 1.56 33.7 1676 2.4 2.0 29.80 1 336 0.1000 0.1200 0.088 1.56 0.080 1.74 370 295 295 245 395 380

    400 53 30 2.0 1.56 37.1 2032 2.6 2.2 33.60 1 690 0.0778 0.0934 0.088 1.56 0.080 1.81 410 325 335 275 455 435

    500 53 3.4 2.0 1.72 41.2 2531 3.0 2.2 37.40 2 120 0.0605 0.0726 0.087 1.57 0.079 1.76 435 345 355 295 490 480

    630 53 3.9 2.0 1.88 46.2 3183 3.4 2.4 42.20 2 709 0.0469 0.0563 0.086 1.57 0.077 1.77 485 390 395 320 560 550

    800 53 3.9 2.0 1.88 52.0 4120 3.4 2.4 48.00 3 430 0.0367 0.0440 0.083 1.75 0.077 1.98 525 442 420 350 640 600

    1000 53 4.0 2.5 2.04 57.3 4812 3.4 2.6 52.20 4 064 0.0291 0.0349 0.082 1.94 0.076 2.20 570 485 445 380 740 720

    ARMOURED UNARMOURED ARMOURED UNARMOURED CURRENT RATINGS

    Cross Min . Th icknes s Nominal Min . Overa ll Approx. Thi ckness Nom. Overa ll Approx. Max. D .C . Max. A .C . Approx. Approx. Approx. Approx. D ir ec t in Ground In Duct In A ir

    sectional No. of of PVC Dimensions Thickness Diameter Net Wt. of insulation Thickness Diameter Net Wt. Resistance Resistance Reactance Capacitance Reactance Capacitance 2 3 2 3 2 3

    area of Wires in su la tion of Armour of PVC (Appros .) of Cab le (Nom. ) of outer (Approx. ) of Cab le a t 20C at 70C at 50 Hz a t 50 Hz Cab le s Cab le s Cab le s Cab le s Cab le s Cab le s

    c on du ctor (Nom. ) Wir e Outer S hea th s he ath

    (mm) (mm) (mm) (mm) (mm) (Kg/Km) (mm) (mm) Ohms/Km Ohms/Km Ohms/Km mfd/Km Ohm/Km mfd/Km Amps Amps Amps Amps Amps Amps

    Unarmoured1. Aluminium2. Insulation - PVC3. Outer Sheath - PVC

    Conductor -

    4567

    123Unarmoured

    Armoured

    Armoured4.5. Insulation - PVC6. Armouring - Wire (Non Magnetic)7. Outer Sheath - PVC

    Conductor - Aluminium

    18

  • 8/22/2019 BMI Catalog

    19/56

    ARMOURED UNARMOURED CURRENT RATING

    Cross Min. Thickness Min. Nominal Min. Overall Approx. Nom. Overall Net. Max. D.C. M ax. A.C . Approx. Approx. D irect in In Duct In Ductsectional No. of PVC Thi ckness Dimensions Thickness Diameter Net. Thickness Diameter Wt. of Resist- Resist- Capacit- Capacit- Grounda re a of of insulation of PVC of Armour of PVC (Approx. ) Wt. of of Outer (Approx.) of Cable ance at ance at a nce at ance

    conductor Wires (Nom.) inner Outer Sheath Cable Sheath (Approx.) 20C 70C 50 HZ

    sheath Strip Wire Strip Wire Strip Wire Strip Wire

    (mm ) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) ( Kg/Km ) ( Kg/Km ) (mm) (mm) (K g/Km) (Ohms /Km) (Ohms /Km) (Ohms/Km ) (mfd/ Km ) ( Amps ) ( Amps ) ( Amp s)

    Unarmoured1. Copper2. Insulation - PVC3. Inner Sheath - PVC4. Outer Sheath - PVC

    Conductor -

    Armoured5.6. Insulation - PVC7. Inner Sheath - PVC8. Armouring - Wire/Strip9. Outer Sheath - PVC

    Conductor - Copper

    567

    124Unarmoured

    Armoured

    3

    89

    1.5 1 0.80 0.30 1.40 1.24 13.5 407 1.80 10.40 194 12.1 14.5 0.126 0.14 23 20 20

    2.5 1 0.90 0.30 1.40 1.24 15.0 482 1.80 11.90 248 7.4 8.87 0.119 0.15 32 27 27

    4 1 1.00 0.30 1.4 1.24 16.5 596 1.80 13.40 316 4.6 5.52 0.116 0.16 41 35 35

    6 1 1.00 0.30 1.40 1.24 17.5 711 1.80 14.40 397 3.08 3.69 0.110 0.19 50 44 45

    10 6 1.00 0.30 1.40 1.24 19.0 863 1.80 15.90 515 1.83 2.19 0.100 0.22 70 58 60

    16 6 1.00 0.30 4x0.8 1.60 1 .40 1.40 18.8 20.4 721 917 1.80 18.00 531 1.115 1.38 0.097 0.29 90 75 78

    25 6 1.20 0.30 1x0.8 1.60 1.40 1.40 20.8 22.4 9 65 1193 2.00 20.40 767 0.722 0.87 0.097 0.32 115 97 105

    35 6 1.20 0.30 4 x0.8 1.60 1.40 1.40 21.8 23.4 1176 1405 2.00 21.40 966 0.524 0.627 0.097 0.37 140 120 125

    50 6 1.40 0.30 4x0.8 1.60 1.40 1.56 2 4.3 26.2 1494 1768 2.00 23.90 1254 0.387 0.463 0.094 0.37 165 145 155

    70 12 1.40 0.30 4x0.8 1 .60 1.56 1.56 2 6.7 2 8.3 1963 2250 2.00 26.00 1677 0.268 0.321 0.090 0.44 205 180 195

    95 15 1.60 0.40 4x0.8 2 .00 1.56 1.56 3 0.2 3 2.6 2577 3080 2.20 29.90 2274 0.193 0.231 0.090 0.44 240 215 230

    120 18 1.60 0.40 4x0.8 2 .00 1.56 1.72 31.7 3 4.4 3082 3639 2 .20 31.40 2760 0.153 0.184 0.087 0.49 275 235 265

    150 18 1.80 0.40 4x0.8 2 .00 1.72 1.72 35.4 3 7.8 3765 4369 2 .40 35.20 3409 0.124 0.149 0.087 0.49 310 270 305

    185 30 2.00 0.50 4x0.8 2 .00 1.88 1.88 39.4 41.5 4626 5281 2 .40 38.50 4201 0.0991 0.120 0.087 0.49 350 300 350

    240 34 2.20 0.50 4x0.8 2 .50 2.04 2.04 42.5 45.9 5865 6893 2 .60 42.00 5409 0.0754 0.091 0.087 0.50 405 345 410

    300 34 2.40 0.60 4x0.8 2 .50 2.20 2.20 48.0 51.9 7250 8424 2 .80 45.10 6732 0.0601 0.073 0.086 0.52 450 385 465

    400 53 2.60 0.70 4x0.8 3 .15 2.36 2.52 55.5 60.5 9188 11171 3.20 52.50 8466 0.0470 0.059 0.086 0.53 490 425 530

    TECHNICAL DATA

    2 CORE COPPER ARMOURED & UNARMOURED POWER CABLES

    19

  • 8/22/2019 BMI Catalog

    20/56

    ARMOURED UNARMOURED CURRENT RATING

    Cros s M in. No. Thi ckne ss Min. Nomina l M in. Ove ra ll Ap prox . Nom. Ove ra ll N et Wt . Max . D. C. Max . A. C. App rox A pprox Di re ct i n In Du ct In Ai rsectional of Wires of PVC Thickness Dimensions Thickness Diameter Net Wt. Thickness Diameter of Cable Resistance Resistance Capacitance Capacitance Groundarea of insulat ion of PVC of Armour of PVC Outer (Approx .) o f Cab le of Outer (Approx) (Approx .) at 20C at 70C at 50 Hz

    conductor (Nom.) inner Sheath Sheath

    sheat h S tr ip Wi re S tr ip Wi re St ri p Wi re St ri p W ir e

    (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (Kg/Km) Ohms/Km Ohs/Km Ohms/Km mfd/Km Amps Amps Amps

    TECHNICAL DATA

    2 CORE ALUMINIUM PVC ARMOURED & UNARMOURED POWER CABLES

    4 123Unarmoured

    Armoured 8 5679

    Unarmoured1. Aluminium2. Insulation - PVC3. Inner Sheath - PVC4. Outer Sheath - PVC

    Conductor -

    Armoured5.6. Insulation - PVC7. Inner Sheath - PVC8. Armouring - Wire/Strip9. Outer Sheath - PVC

    Conductor - Aluminium

    1.5 1 0.80 0.30 1.40 1.24 13.5 390 1.80 10.40 170 18.10 21.72 0.126 0.140 18 16 16

    2.5 1 0.90 0.30 1.40 1.24 15.0 450 1.80 11.90 210 12.10 14.52 0.119 0.150 25 21 21

    4 1 1.00 0.30 1.40 1.24 16.5 550 1.80 13.40 265 7.41 8.89 0.116 0.160 32 27 27

    6 1 1.00 0.30 1.40 1.24 17.5 640 1.80 14.40 320 4.61 5.53 0.110 0.190 40 34 35

    10 1 1.00 0.30 1.40 1.24 19.0 745 1.80 15.90 390 3.08 3.70 0.100 0.220 55 45 47

    16 6 1.00 0.30 4x0.8 1.60 1.40 1.40 18.8 20.4 528 725 1.80 18.00 338 1.91 2.29 0.097 0.290 70 58 59

    25 6 1.20 0.30 4 x0.8 1.60 1.40 1.40 20.8 22.4 658 887 2.00 20.40 461.0 1.20 1.44 0.097 0.320 90 76 7835 6 1.20 0.30 4 x0.8 1.60 1.40 1.40 21.8 23.4 747 974 2.00 21.40 537.0 0.868 1.04 0.097 0.370 110 92 99

    50 6 1.40 0.30 4x0.8 1.60 1.40 1.56 24.3 26.2 923 1 198 2.00 23.90 683.0 0.641 0.77 0.94 0.370 135 115 125

    70 12 1.40 0.30 4x0.8 1.60 1.56 1.56 2 6.7 28.3 1124 1411 2 .00 26.00 838.0 0.443 0.53 0.090 0.440 160 140 150

    95 15 1.60 0.40 4x0.8 2.00 1.56 1 .56 30.2 3 2.6 1411 1915 2 .20 29.90 1107.0 0.320 0.38 0.090 0.440 190 170 185

    120 15 1.60 0.40 4x0.8 2.00 1.56 1 .72 31.7 34.4 1613 2170 2 .20 31.40 1291.0 0.253 0.30 0.087 0.490 210 190 210

    150 15 1.80 0.40 4x0.8 2.00 1.72 1 .72 35.4 37.8 1948 2553 2 .40 35.20 1592.0 0.206 0.25 0.087 0.490 240 210 240

    185 30 2.00 0.50 4x0.8 2.00 1.88 1 .88 3 9.4 4 1.5 2357 3013 240 38.50 1933.0 0.164 0.20 0.087 0.490 275 240 275

    240 30 2.20 0.50 4x0.8 2.50 2.04 2 .04 42.5 45.9 2880 3908 2 .60 42.00 2424.0 0.125 0.15 0.087 0.500 320 275 325

    300 30 2.40 0.60 4x0.8 2.50 2.20 2 .20 48.5 51.9 3500 4675 2 .80 48.10 2981.0 0.100 0.12 0.086 0.520 355 305 365

    400 53 2.60 0.70 4x0.8 3.15 2.36 2 .52 55.5 60.5 4560 6560 3 .20 52.50 3755.0 0.0778 0.09 0.086 0.530 385 345 420

    20

  • 8/22/2019 BMI Catalog

    21/56

    ARMOURED UNARMOURED CURRENT RATING

    Cross Min. Thickness Min. Nominal Min. Overall Approx. Nom. Overall Net. Max. D.C. M ax. A.C . Approx. Approx. Direct in In Duct In Ductsectional No. of PVC Thi ckness Dimensions Thickness Diameter Net. Thickness Diameter Wt. of Resist- Resist- Capacit- Capacit- Grounda re a of of insulation of PVC of Armour of PVC (Approx. ) Wt. of of Outer (Approx.) of Cable ance at ance at a nce at ance

    conductor Wires (Nom.) inner Outer Sheath Cable Sheath (Approx.) 20C 70C 50 HZ

    sheath Strip Wire Strip Wire Strip Wire Strip Wire

    (mm ) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (Kg/Km ) ( Kg/Km ) (mm) (mm) (K g/Km) (Ohms /Km) (Ohms /Km) (Ohms/Km ) (mfd/ Km ) ( Amps ) ( Amps ) ( Amp s)

    Unarmoured1. Copper2. Insulation - PVC3. Inner Sheath - PVC4. Outer Sheath - PVC

    Conductor -

    Armoured5.6. Insulation - PVC7. Inner Sheath - PVC8. Armouring - Wire/Strip9. Outer Sheath - PVC

    Conductor - Copper

    567

    124Unarmoured

    Armoured

    3

    89

    1.5 1 0.80 0.3 1.4 1.24 14.0 442 1.80 11.00 218 12.1 14.5 0.126 0.14 21 17 17

    2.5 1 0.90 0.3 1.4 1.24 15.0 542 1.80 12.00 284 7.41 8.87 0.119 0.15 27 24 24

    4 1 1.00 0.3 1.4 1.24 16.5 663 1.80 13.50 372 4.61 5.52 0.116 0.41 36 30 30

    6 1 1.00 0.3 1.4 1.24 17.5 789 1.80 14.40 470 3.08 3.69 0.110 0.47 45 39 38

    10 6 1.00 0.3 1.4 1.40 19.5 1017 1.80 15.60 629 1.83 2.19 0.100 0.56 60 57 50

    16 6 1.00 0.3 4x0.8 1.6 1.40 1.40 18.6 20.2 859 1057 1.80 18.40 705 1.15 1.38 0.097 0.76 77 66 64

    25 6 1.20 0.3 4x0.8 1.6 1.40 1.40 21.3 22.9 1210 1431 2.00 21.50 1046 0.727 0.87 0.097 0.86 99 90 81

    35 6 1.20 0.3 4x0.8 1 .6 1.40 1.40 23.1 24.7 1532 1773 2.00 23.30 1350 0.524 0.627 0.097 0.98 120 110 99

    50 6 1.40 0.3 4x0.8 1 .6 1.56 1.56 26.6 28.2 2016 2305 2.00 26.50 1783 0.387 0.463 0.094 1.02 145 135 125

    70 12 1.40 0.4 4x0.8 2 .0 1.56 1.56 29.6 32.0 2684 3173 2.20 29.90 2446 0.268 0.321 0.090 1.18 175 165 150

    95 15 1.60 0.4 4x0.8 2 .0 1.56 1.72 33.5 36.2 3564 4169 2.20 33.80 3286 0.193 0.231 0.090 1.20 210 200 175

    120 18 1.60 0.4 4x0.8 2 .0 1.72 1.72 37.0 39.4 4371 5001 2.20 37.00 4034 0.153 0.184 0.087 1.31 240 230 195

    150 18 1.80 0.5 4x0.8 2 .0 1.88 1.88 40.1 42.4 5309 5974 2.40 40.10 4954 0.124 0.149 0.087 1.31 270 265 225

    185 30 2.00 0.5 4x0.8 2 .5 1.88 2.04 44.2 47.9 6502 7648 2.60 44.60 6145 0.0991 0.12 0.087 1.31 300 305 225

    240 34 2.20 0.6 4x0.8 2.5 2.20 2.20 5 1.3 53.7 8 422 9648 2.80 50.70 8018 0.0754 0 .0912 0.087 1.34 345 355 295

    300 34 2.40 0.6 4x0.8 2.5 2.36 2 .36 55.0 58.4 10356 11710 3.00 55.50 9920 0.0601 0 .0739 0.086 1.41 385 400 335

    400 53 2.60 0.7 4x0.8 3.2 2.52 2 .68 62.6 67.6 13107 15315 3.40 63.80 12717 0.047 0.0592 0.086 1.45 425 455 360

    TECHNICAL DATA

    3 CORE COPPER PVC ARMOURED & UNARMOURED POWER CABLES

    21

  • 8/22/2019 BMI Catalog

    22/56

    Unarmoured1. Aluminium2. Insulation - PVC3. Inner Sheath - PVC4. Outer Sheath - PVC

    Conductor -

    Armoured5.6. Insulation - PVC7. Inner Sheath - PVC8. Armouring - Wire/Strip9. Outer Sheath - PVC

    Conductor - Aluminium

    4 123Unarmoured

    Armoured 8 5679

    2.5 1 0.9 0.3 1.40 1.24 15.0 500 1.80 12.00 230 12.10 14.52 0.119 0.150 21 18 18

    4 1 1.0 0.3 1.40 1.24 16.5 595 1.80 13.50 300 7.41 8.89 0.116 0.410 28 23 23

    6 1 1.0 0.3 1.40 1.24 17.5 685 1.80 14.40 350 4.61 5.53 0.110 0.470 35 30 30

    10 1 1.0 0.3 1.40 1.40 19.5 830 1.80 15.60 435 3.08 3.70 0.100 0.560 46 39 40

    16 6 1.0 0.3 4x0.8 1.60 1.40 1.40 18.6 20.2 569 767 1.80 18.40 415 1.91 2.29 0.097 0.760 60 50 51

    25 6 1.2 0.3 4x0.8 1.60 1.40 1.40 21.3 22.9 750 971 2.00 21.50 586 1.20 1.44 0.097 0.860 76 63 70

    35 6 1.2 0.3 4x0.8 1.60 1.40 1.40 23.1 24.7 888 1129 2.00 23.30 705 0.641 1.04 0.097 0.980 92 77 86

    50 6 1.4 0.3 4x0.8 1.60 1.56 1.56 26.6 28.2 1147 1436 2.00 26.50 913 0.310 0.77 0.094 1.020 110 95 105

    70 12 1.4 0.4 4x0.8 2.00 1.56 1.56 2 9.6 32.0 1426 1914 2.20 29.90 1187 0.443 0.53 0.090 1.180 135 115 130

    95 15 1.6 0.4 4x0.8 2.00 1.56 1.72 3 3.5 36.2 1815 2420 2.20 33.80 1538 0.320 0.38 0.090 1.200 165 140 155

    120 15 1.6 0.4 4x0.8 2.00 1.72 1.72 3 7.0 3 9.4 2166 2796 2.20 37.00 1829 0.253 0.30 0.087 1.310 185 155 180

    150 15 1.8 0.5 4x0.8 2.00 1.88 1.88 4 0.1 4 2.4 2584 3249 2.40 40.10 2228 0.206 0.25 0.087 1.310 210 175 205

    185 30 2.0 0.5 4x0.8 2.50 1.88 2.04 4 4.2 4 7.9 3009 4246 2.60 44.60 2743 0.164 0.20 0.087 1.310 235 200 240

    240 30 2.2 0.6 4x0.8 2.50 2.20 2.20 5 0.3 5 3.7 3945 5171 2.80 50.70 3541 0.125 0.15 0.087 1.340 275 235 280

    300 30 2.4 0.6 4x0.8 2.50 2.36 2.36 5 5.0 5 8.4 4731 6085 3.00 55.50 4296 0.100 0.12 0.086 1.410 305 260 315

    400 53 2.6 0.7 4x0.8 3.15 2.52 2.68 62.6 6 7.6 5927 8135 3.40 63.80 5537 0.0778 0.09 0.086 1.450 335 290 375

    1.5 1 0.8 0.3 1.40 1.24 14.0 420 1.80 11.00 190 18.10 21.72 0.126 0 .140 16 14 13

    ARMOURED UNARMOURED CURRENT RATING

    Cross Min. Thickness Min. Nominal Min. Overall Approx. Nom. Overall Net. Max. D.C. M ax. A.C . Approx. Approx. Direct in In Duct In Ductsectional No. of PVC Thickness Dimensions Thickness Diameter Net. Thickness Diameter Wt. of Resist- Resist- Capacit- Capacit- Grounda re a of of insulation of PVC of Armour of PVC (Approx. ) Wt. of of Outer (Approx.) of Cable ance at ance at a nce at ance

    conductor Wires (Nom.) inner Outer Sheath Cable Sheath (Approx.) 20C 70C 50 HZ

    sheath Strip Wire Strip Wire Strip Wire Strip Wire

    (mm ) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) ( Kg/Km ) ( Kg/Km ) (mm) (mm) (K g/Km) (Ohms /Km) (Ohms /Km) (Ohms/Km ) (mfd/ Km ) ( Amps ) ( Amps ) ( Amp s)

    TECHNICAL DATA

    3 CORE ALUMINIUM PVC ARMOURED & UNARMOURED POWER CABLES

    22

  • 8/22/2019 BMI Catalog

    23/56

    Unarmoured

    1. Copper2. Insulation - PVC3. Inner Sheath - PVC4. Outer Sheath - PVC

    Conductor -

    Armoured5.6. Insulation - PVC7. Inner Sheath - PVC8. Armouring - Wire/Strip9. Outer Sheath - PVC

    Conductor - Copper

    567

    124Unarmoured

    Armoured

    3

    89

    TECHNICAL DATA

    3.5 CORE COPPER PVC ARMOURED POWER CABLESType Cross Min. Thickness Min. Nominal Min. Thickness Overall Approx. Max. D.C . Max. A.C . Approx. Approx. CURRENT RATING

    sectional N o. of of PVC Thickness Diensions of PVC Diameter Net Wt. Resistance Resistance Reactance Capacitance Direct in In Airarea Wires insulation PVC inner of Armour Outer sheath (Approx.) of Cable at 20 at 70 Hz at 50 Hz Ground

    (Nom.) sheath Strip Wire Strip Wire Strip Wire Strip Wire2(mm ) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (Kg/Km) ( ) (Ohms/Km) (Ohms/Km) (Ohms/Km) (mfd/Km) (Amps) (Amps)Kg/Km

    YWY/YFY 25/16 6/6 1.2/1.0 0.3 4x0.8 1.60 1.40 1.40 23.8 25.4 1438 1685 0.727 0.87 0.097 0.86 99 90

    YWY/YFY 35/16 6/6 1 .2/1.0 0.3 4x0.8 1.60 1.40 1.40 24.8 26.4 1741 2004 0.524 0.627 0.097 0.98 120 110

    YWY/YFY 50/25 6/6 1 .4/1.2 0.3 4x0.8 1.60 1.56 1.56 28.4 30.0 2313 2606 0.387 0.463 0.094 1.02 145 135

    YWY/YFY 70/35 12/6 1.4/1.2 0.4 4x0.8 2.00 1.56 1.56 32.5 34.9 3113 3657 0.268 0.321 0.090 1.18 175 165

    YWY/YFY 95/50 15/6 1.6/1.4 0.4 4x0.8 2.00 1.56 1.72 36.2 38.9 4115 4756 0.193 0.231 0.090 1.20 210 200

    YWY/YFY 120/70 18/12 1.6/1.4 0.5 4x0.8 2.00 1.72 1.88 39.3 42.1 5125 5827 0.153 0.184 0.087 1.31 240 230

    YWY/YFY 150/70 18/12 1.8/1.4 0.5 4x0.8 2.00 1.88 1.88 44.0 46.4 6095 6825 0.124 0.149 0.087 1.31 270 265YWY/YFY 185/95 30/15 2.0/1.6 0.5 4x0.8 2.50 2.04 2.04 48.8 52.2 7595 8799 0.0991 0.120 0.087 1.31 300 305

    YWY/YFY 240/120 34/18 2.2/1.6 0.6 4x0.8 2.50 2.20 2.36 55.2 58.9 9738 11128 0.0754 0.0912 0.087 1.34 345 355

    YWY/YFY 300/150 34/18 2.4/1.8 0.6 4x0.8 3.15 2.36 2.52 59.7 64.7 11945 14064 0.0601 0.0739 0.086 1.41 385 400

    YWY/YFY 400/185 53/30 2.6/2.0 0.7 4x0.8 3.15 2.68 2.68 68.6 73.3 15139 17523 0.0470 0.0592 0.086 1.45 425 455

    3.5 CORE COPPER PVC UNARMOURED POWER CABLESType Cross Minimum Thickness Minimum Normal Overall Net Weight Max. DC Max. AC Approx. Approx. CURRENT RATINGS

    s ect io na l Numbers o f P VC Thi ckne ss o f Thi ckn es s D iamete r of Cable Re si st an ce Res is tanc e React anc e Capaci tanc e Di re ct i n In Duct In Ai rarea of of Wires Insulation PVC Inner of Outer (Approx.) (Approx.) at 20C at 70C at 50 Hz Groundconductor (Nom.) sheath sheathsqmm (mm) (mm) (mm) (mm) (Kg/Km) (Ohm/Km) (Ohm/Km) (Ohm/Km) (mfd/Km) (Amps) (Amps) (Amps)

    YY 25/16 6/6 1.2/1.0 0.30 2.00 24.00 1248 0.73 0.87 0.097 0.86 99 81 90YY 35/16 6/6 1.2/1.0 0.30 2.00 25.00 1541 0.524 0.627 0.097 0.98 120 99 110

    YY 50/25 6/6 1.4/1.2 0.40 2.00 28.30 2058 0.387 0.463 0.094 1.02 145 125 135

    YY 70/35 12/6 1.4/1.2 0.40 2.20 32.80 2845 0.268 0.321 0.090 1.18 175 150 165

    YY 95/50 15/6 1.6/1.4 0.50 2.20 36.50 3810 0.193 0.231 0.090 1.20 210 175 200

    YY 120/70 18/12 1.6/1.4 0.50 2.40 39.70 4804 0.153 0.184 0.087 1.31 240 195 230

    YY 150/70 18/12 1.8/1.4 0.50 2.40 44.00 5699 0.124 0.149 0.087 1.31 270 225 265

    YY 185/95 30/15 2.0/1.6 0.50 2.60 48.90 7161 0.099 0.1200 0.087 1.31 300 255 305

    YY 240/120 34/18 2.2/1.6 0.60 3.00 56.00 9340 0.075 0.0912 0.087 1.34 345 295 355

    YY 300/150 34/18 2.4/1.8 0.60 3.20 60.60 11521 0.060 0.0739 0.086 1.41 385 335 400

    YY 400/185 53/30 2.6/2.0 0.70 3.40 69.40 14651 0.0470 0.0592 0.086 1.45 425 360 455

    23

  • 8/22/2019 BMI Catalog

    24/56

    Unarmoured1. Aluminium2. Insulation - PVC3. Inner Sheath - PVC4. Outer Sheath - PVC

    Conductor -

    Armoured5.6. Insulation - PVC7. Inner Sheath - PVC8. Armouring - Wire/Strip9. Outer Sheath - PVC

    Conductor - Aluminium

    4 123Unarmoured

    Armoured 8 5679

    TECHNICAL DATA

    3.5 CORE ALUMINIUM PVC ARMOURED POWER CABLESType Cross Min. Thickness Min. Nominal Min. Overall Approx. Max. D.C. Max. A.C. Approx. Approx. CURRENT RATING

    sectional No. of of PVC Thickness Dimensions T hickness Diameter Net. Wt. Resistance Resi stance Re actance Capa citance Direct in In I narea Wires insulation PVC inner of Armour of PVC (Approx.) of Cable at 20C at 70C a t 50 Hz Ground Duct Air

    (Nom.) sheath Outer sheathStrip Wire Strip Wire Strip Wire Strip Wire

    (mm ) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (Kg/Km) (Kg/Km) (Ohms/Km) (Ohms/Km) (Ohms/Km) (mfd/Km) (Amps) (Amps) (Amps)

    AYWY/AYFY 25/16 6/6 1.2/1.0 0.3 4x0.8 1.60 1.40 1.40 23.8 25.4 882 1128 1.200 1.44 0.097 0.86 76 63 70

    AYWY/AYFY 35/16 6/6 1.2/1.0 0.3 4x0.8 1.60 1.40 1.40 24.8 26.4 1000 1263 0.868 1.04 0.097 0.98 92 77 86

    AYWY/AYFY 50/25 6/6 1.4/1.2 0.3 4x0.8 1.60 1.56 1.56 28.4 30.0 1289 1583 0.641 0.77 0.094 1.02 100 95 105

    AYWY/AYFY 70/35 1 2/6 1.4/1.2 0.4 4x0.8 2.00 1.56 1.56 32.5 34.9 1640 2184 0.443 0.53 0.090 1.18 135 115 130

    AYWY/AYFY 95/50 15/6 1.6/1.4 0.4 4x0.8 2.00 1.56 1.72 36.21 38.9 2075 2716 0.320 0.38 0.090 1.20 165 140 155

    AYWY/AYFY 120/70 15/12 1.6/1.4 0.5 4x0.8 2.00 1.72 1.88 39.3 42.1 2502 3203 0.253 0.30 0.087 1.31 185 155 180

    AYWY/AYFY 150/70 15/12 1.8/1.4 0.5 4x0.8 2.00 1.88 1.88 44.0 46.4 2950 3680 0.206 0.25 0.087 1.31 210 175 205

    AYWY/AYFY 185/95 30/15 2.0/1.6 0.5 4x0.8 2.50 2.04 2.04 48.8 52.2 3610 4813 0.164 0.20 0.087 1.31 235 200 240

    AYWY/AYFY 240/120 30/15 2.2/1.6 0.6 4x0.8 2.50 2.20 2.36 55.2 58.9 4526 5715 0.125 0.15 0.087 1.34 275 235 280

    AYWY/AYFY 300/150 30/15 2.4/1.8 0.6 4x0.8 3.15 2.36 2.52 59.7 64.7 5400 7531 0.100 0.12 0.086 1.41 305 260 315

    AYWY/AYFY 400/185 53/30 2.6/2.0 0.7 4x0.8 3.15 2.68 2.68 68.6 73.3 6827 9211 0.0778 0.09 0.086 1.45 335 290 375

    3.5 CORE ALUMINIUM PVC UNARMOURED POWER CABLESType Cross Min. No. of Thi ckness of Min. Thickness Nom. Overall Net. Wt. Max. D.C . Max. A.C . Approx. Approx. CURRENT RATING

    s ec ti on al a rea Wi re s PVC Insula ti on o f P VC i nne r Thi ckne ss o f Di amet er o f Cabl e Res is tance Res is tance React anc e Capaci tanc e Di re ct i n In Inof conductor (Nom.) sheath Outher sheath (Approx) (Approx) at 20C at 70C at 50 Hz Ground Duct Air

    sqmm (mm) (mm) (mm) (mm) (Kg/Km) (Ohm/Km) (Ohm/Km) (Ohm/Km) (mfd/Km) (Amps) (Amps) (Amps)

    AYY 25/16 6/6 1.2/1.0 0.30 2.00 24.00 692 1.20 1.44 0.097 0.86 76 63 70

    AYY 35/16 6/6 1.2/1.0 0.30 2.00 25.00 799 0.868 1.04 0.097 0.98 92 77 86

    AYY 50/25 6/6 1.4/1.2 0.30 2.00 28.50 1034 0.641 0.77 0.094 1.02 110 95 105

    AYY 70/35 12/6 1.4/1.2 0.40 2.20 32.80 1373 0.443 0.53 0.090 1.18 135 115 130

    AYY 95/50 15/6 1.6/1.4 0.40 2.20 36.50 1771 0.320 0.38 0.090 1.20 165 140 155

    AYY 120/70 15/12 1.6/1.4 0.50 2.40 39.70 2180 0.253 0.30 0.087 1.31 185 155 180

    AYY 150/70 15/12 1.8/1.4 0.50 2.40 44.00 2554 0.206 0.25 0.087 1.31 210 175 205

    AYY 185/95 30/15 2.0/1.6 0.50 2.60 48.90 3176 0.164 0.20 0.087 1.31 235 200 240

    AYY 240/120 30/15 2.2/1.6 0.60 3.00 56.00 4128 0.125 0.15 0.087 1.34 275 235 280

    AYY 300/150 30/15 2.4/1.8 0.60 3.20 60.60 4989 0.100 0.12 0.086 1.41 305 260 315

    AYY 400/185 53/30 2.6/2.0 0.70 3.40 69.40 6344 0.0778 0.099 0.086 1.45 335 290 375

    24

  • 8/22/2019 BMI Catalog

    25/56

    Cross Min. Thickness Min. ARMOURED UNARMOURED Max. D.C. Max. A.C. Approx Approx CURRENT RATINGsectional No. of of PVC Thickness Nominal Min. Thickness of Overall Diameter Approx. Net Wt. Nom. Overall Net Wt. Resistance Resistance Resistance Capacit-area of Wires insulat ion of PVC Dimensions of Armour PVC Outer Sheath (Approx .) o f Cab le Thickness Diameter o f Cab le at 20C at 70C at 50 Hz -ance Direc t In Inconductor (Nom.) inner of Outer (Approx) (Approx.) in Duct Air

    sheath Strip Wire Strip Wire Strip Wire Strip Wire Sheath Ground

    mm (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) ( Kg/Km ) (K g/Km) (mm) (mm) (K g/Km) Ohms/Km Ohms/Km Ohms/Km mfd/ Km Amps Amp s Amps

    TECHNICAL DATA

    4 CORE COPPER PVC ARMOURED & UNARMOURED POWER CABLES

    Unarmoured

    1. Copper2. Insulation - PVC3. Inner Sheath - PVC4. Outer Sheath - PVC

    Conductor -

    Armoured5.6. Insulation - PVC7. Inner Sheath - PVC8. Armouring - Wire/Strip9. Outer Sheath - PVC

    Conductor - Copper

    567

    124Unarmoured

    Armoured

    3

    89

    1.5 1 0.8 0.3 1.4 1.24 14.5 503 1.80 11.70 256 12.1 14.5 0.126 0.14 21 17 17

    2.5 1 0.9 0.3 1.4 1.24 16.0 616 1.80 13.20 335 7.4 8.87 0.119 0.15 27 24 24

    4 1 1.0 0.3 1.4 1.24 17.5 771 1.80 15.00 446 4.6 5.52 0.116 0.41 36 30 30

    6 1 1.0 0.3 1.4 1.24 19.0 947 1.80 16.00 576 3.1 3.69 0.110 0.47 45 39 38

    10 6 1.0 0.3 4X0.8 1.60 1.40 1.40 21.5 23.0 1045 1273 1.80 19.00 773 1.8 2.19 0.100 0.56 60 57 50

    16 6 1.0 0.3 4X0.8 1.60 1.40 1.40 22.2 23.8 1113 1352 2.00 22.40 940 1.2 1.38 0.097 0.76 77 66 64

    25 6 1.2 0.3 4x0.8 1.60 1.40 1.40 23.6 25.2 1529 1779 2.00 23.80 1342 0.727 0.87 0.097 0.86 99 90 81

    35 6 1.2 0.3 4x0.8 1.60 1.40 1.56 25.9 27.8 1955 2254 2.00 26.10 1744 0.524 0.62 0.097 0.98 120 110 99

    50 6 1.4 0.4 4x0.8 2.00 1.56 1.56 30.3 32.7 2593 3096 2.20 30.60 2347 0.387 0.46 0.094 1.02 145 135 125

    70 12 1.4 0.4 4x0.8 2.00 1.56 1.56 33.4 35.8 3459 4015 2.20 33.70 3183 0.268 0.32 0.090 1.18 175 165 150

    95 15 1.6 0.4 4x0.8 2.00 1.72 1.72 38.2 40.60 4643 5280 2.40 38.60 4330 0.193 0.23 0.090 1.20 210 200 175

    120 18 1.6 0.5 4x0.8 2.00 1.88 1.88 41.7 44.1 5702 6393 2.40 41.70 5330 0.153 0.18 0.087 1.31 240 230 195

    150 18 1.8 0.5 4x0.8 2.50 1.88 2.04 44.7 48.4 6872 8012 2.60 45.10 6511 0.124 0.14 0.087 1.31 270 265 225

    185 30 2.0 0.6 4x0.8 2.50 2.04 2.20 50.1 53.8 8519 9782 2.80 50.80 8152 0.0991 0 .12 0.087 1.31 300 305 255

    240 34 2.2 0.6 4x0.8 2.50 2.36 2.36 56.7 60.1 11008 1 2415 3.00 57.20 10557 0 .0754 0.091 0.087 1.34 345 355 295

    300 34 2.4 0.7 4x0.8 3.15 2.52 2.68 62.9 68.0 13610 1 5877 3.40 64.10 13218 0 .0601 0.073 0.086 1.41 385 400 335

    400 53 2.6 0.7 4x0.8 3.15 2.84 2.84 70.6 75.3 17213 1 9697 3.60 71.50 16729 0 .0470 0.059 0.086 1.45 425 455 360

    25

  • 8/22/2019 BMI Catalog

    26/56

    Unarmoured

    1. Aluminium2. Insulation - PVC3. Inner Sheath - PVC4. Outer Sheath - PVC

    Conductor -

    Armoured5.6. Insulation - PVC7. Inner Sheath - PVC8. Armouring - Wire9. Outer Sheath - PVC

    Conductor - Aluminium

    4 123Unarmoured

    Armoured 8 5679

    Cross Min. Thickness Min. ARMOURED UNARMOURED Max. D.C. Max. A.C. Approx Approx CURRENT RATINGsectional No. of of PVC Thickness Nominal Min. Thickness of Overall Diameter Approx. Net Wt. Nom. Overall Net Wt. Resistance Resistance Resistance Capacit-area of Wires insulat ion of PVC Dimensions of Armour PVC Outer Sheath (Approx .) o f Cab le Thickness Diameter o f Cab le at 20C at 70C at 50 Hz -ance Direc t In In

    conductor (Nom.) inner of Outer (Approx) (Approx.) in Duct Airsheath Strip Wire Strip Wire Strip Wire Strip Wire Sheath Ground

    2mm (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) ( Kg/Km ) (K g/Km) (mm) (mm) ( Kg/Km) Ohms /Km Ohms/Km Ohms/Km mfd/ Km Amps Amps Amps

    TECHNICAL DATA

    4 CORE ALUMINIUM PVC ARMOURED & UNARMOURED POWER CABLES

    1.5 1 0.8 0.3 1.40 1.24 14.5 470 1.80 11.70 210 18.10 21.72 0.126 0.140 16 14 13

    2.5 1 0.9 0.3 1.40 1.24 16.0 560 1.80 13.20 270 12.10 14.52 0.119 0.150 21 18 18

    4 1 1.0 0.3 1.40 1.24 17.5 675 1.80 15.00 340 7.41 8.89 0.116 0.410 28 23 23

    6 1 1.0 0.3 1.40 1.24 19.0 800 1.80 16.00 420 4.61 5.53 0.110 0.470 35 30 30

    10 1 1.0 0.3 4x0.8 1.60 1.40 1.40 21.5 23.0 800 1030 1.80 19.00 510 3.08 3.70 0.100 0.560 46 39 40

    16 6 1.0 0.3 4x0.8 1.60 1.40 1.40 22.2 23.8 860 1120 2.00 22.40 553 1.91 2.29 0.097 0.760 60 50 51

    25 6 1.2 0.3 4x0.8 1.60 1.40 1.40 23.6 25.2 915 1165 2.00 23.80 728 1.20 1.44 0.097 0.860 76 63 7035 6 1.2 0.3 4x0.8 1.60 1.40 1.56 25.9 27.8 1097 1396 2.00 26.10 886 0.868 1.04 0.097 0.980 92 77 86

    50 6 1.4 0.4 4x0.8 2.00 1.56 1.56 30.3 32.7 1432 1935 2.20 30.60 1187 0.641 0.77 0.094 1.020 110 95 105

    70 12 1.4 0.4 4x0.8 2.00 1.56 1.56 33.4 35.8 1781 2336 2.20 33.70 1505 0.443 0.53 0.090 1.180 135 115 130

    95 15 1.6 0.4 4x0.8 2.00 1.72 1.72 38.2 40.60 2311 2948 2.40 38.60 1997 0.320 0.38 0.090 1.200 165 140 155

    120 15 1.6 0.5 4x0.8 2.00 1.88 1.88 41.7 44.1 2762 3453 2.40 41.70 2390 0.253 0.30 0.087 1 .310 1 82 155 180

    150 15 1.8 0.5 4x0.8 2.50 1.88 2.04 44.7 48.4 3246 4387 2.60 45.10 2885 0.206 0.25 0.087 1 .310 2 10 175 205

    185 30 2.0 0.6 4x0.8 2.50 2.04 2.20 50.1 53.8 3982 5245 2.80 50.80 3615 0.164 0.20 0.087 1 .310 2 35 200 240

    240 30 2.2 0.6 4x0.8 2.50 2.36 2.36 56.7 60.1 5038 6445 3.00 57.20 4587 0.125 0.15 0.087 1 .340 2 75 235 280

    300 30 2.4 07 4x0.8 3.15 2.52 2.68 62.9 68.0 6109 8376 3.40 64.10 5716 0.100 0.12 0.086 1.410 305 260 315

    400 53 2.6 0.7 4x0.8 3.15 2.84 2.84 70.6 75.3 7640 10124 3.60 71.50 7157 0.0778 0.09 0.086 1 .450 3 35 290 375

    26

  • 8/22/2019 BMI Catalog

    27/56

    Number No. & Nominal Nominal UNARMOURED ARMOUREDof cores Nominal thickness thickness Nominal Approx. Approx. Armours Armours Minimum Approx. Approx.

    dia of of of inner of thickness overall weight wire strip thickness of overall weightstrand i nsulati on sheath outer sheath di ameter of cable diemensi ons dimensi ons outer sheath di ameter of cablemm mm mm mm mm Kg./km. mm mm mm mm Kg./Km

    CONTROL CABLES

    TECHNICAL DATA

    1.5 SQ MM, SOLID COPPER CONDUCTOR, PVC INSULATED, ARMOURED / UNARMOURED, PVC SHEATHED,

    MULTICORE CONTROL CABLES 1.1KV CONFORMING TO IS:1554 (PART-1)

    Unarmoured

    1.2. Insulation - PVC3. Outer Sheath - PVC

    Conductor - Copper

    Armoured4.5. Insulation - PVC6. Armouring - Wire/Strip7. Outer Sheath - PVC

    Conductor - Copper

    23Unarmoured

    Armoured 5 47

    1

    6

    2 1/1.40 0.80 0.30 1.80 11.30 160 1.40 1.24 13.60 410

    3 1/1.40 0.80 0.30 1.80 11.60 195 1.40 1.24 14.00 450

    4 1/1.40 0.80 0.30 1.80 12.60 220 1.40 1.24 14.80 490

    5 1/1.40 0.80 0.30 1.80 13.30 260 1.40 1.24 15.50 510

    6 1/1.40 0.80 0.30 1.80 14.30 290 1.40 1.24 16.30 595

    7 1/1.40 0.80 0.30 1.80 14.30 315 1.40 1.24 16.30 625

    8 1/1.40 0.80 0.30 1.80 15.50 350 1.40 1.24 18.80 700

    9 1/1.40 0.80 0.30 1.80 16.80 395 1.40 1.24 1910 745

    10 1/1.40 0.80 0.30 1.80 17.50 410 1.40 1.40 20.00 77012 1/1.40 0.80 0.30 1.80 18.30 475 4x0.80 1.24 19.00 750

    14 1/1.40 0.80 0.30 1.80 18.30 530 4x0.80 1.24 20.50 850

    16 1/1.40 0.80 0.30 1.80 20.00 590 4x0.80 1.24 21.00 910

    19 1/1.40 0.80 0.30 2.00 21.00 695 4x0.80 1.24 22.00 1020

    24 1/1.40 0.80 0.30 2.00 24.30 845 4x0.80 1.24 25.00 1230

    27 1/1.40 0.80 0.30 2.00 25.00 920 4x0.80 1.24 26.00 1350

    30 1/1.40 0.80 0.30 2.00 25.50 1005 4x0.80 1.24 27.00 1400

    37 1/1.40 0.80 0.30 2.00 27.80 1180 4x0.80 1.24 29.00 1600

    44 1/1.40 0.80 0.30 2.00 31.00 1330 4x0.80 1.56 31.50 1820

    52 1/1.40 0.80 0.40 2.20 32.50 1650 4x0.80 1.56 33.50 2100

    61 1/1.40 0.80 0.40 2.20 34.00 1800 4x0.80 1.56 35.50 2400

    27

  • 8/22/2019 BMI Catalog

    28/56

    Number No. & Nominal Nominal UNARMOURED ARMOUREDof cores Nominal thickness thickness Nominal Approx. Approx. Armours Armours Minimum Approx. Approx.

    dia of of of inner of thickness overall weight wire strip thickness of overall weightstrand insulation sheath outer sheath diameter of cable diemensions dimensions outer sheath diameter of cablemm mm mm mm mm Kg./km. mm mm mm mm Kg./Km

    TECHNICAL DATA

    2.5 SQ MM, SOLID COPPER CONDUCTOR, PVC INSULATED, ARMOURED / UNARMOURED, PVC SHEATHED,

    MULTICORE CONTROL CABLES 1.1KV CONFORMING TO IS:1554 (PART-1)

    Unarmoured

    1.2. Insulation - PVC3. Outer Sheath - PVC

    Conductor - Copper

    Armoured4.5. Insulation - PVC6. Armouring - Wire/Strip7. Outer Sheath - PVC

    Conductor - Copper

    23Unarmoured

    Armoured 5 47

    1

    6

    2 1/1.78 0.90 0.30 1.80 12.60 205 1.40 1.24 15.00 450

    3 1/1.78 0.90 0.30 1.80 13.20 250 1.40 1.24 15.50 500

    4 1/1.78 0.90 0.30 1.80 14.20 295 1.40 1.24 16.50 585

    5 1/1.78 0.90 0.30 1.80 15.30 350 1.40 1.24 17.40 640

    6 1/1.78 0.90 0.30 1.80 16.40 385 1.40 1.24 18.30 720

    7 1/1.78 0.90 0.30 1.80 16.40 425 1.40 1.24 18.30 750

    8 1/1.78 0.90 0.30 1.80 18.00 500 1.40 1.24 20.50 850

    9 1/1.78 0.90 0.30 1.80 19.60 560 4X0.8 1.40 21.00 870

    10 1/1.78 0.90 0.30 1.80 20.50 590 4X0.8 1.40 21.20 90012 1/1.78 0.90 0.30 2.00 21.50 650 4X0.8 1.40 21.80 1000

    14 1/1.78 0.90 0.30 2.00 22.20 740 4X0.8 1.40 22.80 1100

    16 1/1.78 0.90 0.30 2.00 23.20 840 4X0.8 1.40 24.00 1215

    19 1/1.78 0.90 0.30 2.00 24.90 930 4X0.8 1.40 25.50 1350

    24 1/1.78 0.90 0.30 2.00 28.70 1200 4X0.8 1.40 29.50 1600

    27 1/1.78 0.90 0.30 2.00 30.20 1445 4X0.8 1.56 31.30 1900

    30 1/1.78 0.90 0.30 2.00 30.20 1445 4X0.8 1.56 31.30 1900

    37 1/1.78 0.90 0.40 2.20 32.50 1750 4X0.8 1.56 33.80 2250

    44 1/1.78 0.90 0.40 2.20 32.50 1750 4X0.8 1.56 33.80 2250

    52 1/1.78 0.90 0.40 2.20 38.50 2350 4X0.8 1.56 39.00 3000

    61 1/1.78 0.90 0.40 2.20 41.00 2785 4X0.8 1.56 41.50 3300

    28

  • 8/22/2019 BMI Catalog

    29/56

    ARMOURED UNARMOURED ARMOURED UNARMOURED CURRENT RATING

    Cro ss M in. Thi ckne ss Nomina l M in. Ove ra ll App rox . Thi ckne ss Nom ina l Ove ra ll Ap prox . Max. D .C . Max . A. C. Ap prox . Ap prox . A pprox . Ap prox . D ir ect Insectional No. of of PVC Dimensions Thickness Diameter Net Wt. insulation Thickness Diameter Net Wt. Resistance Resistance Reactance Capacitance Reactance Capacitance in Aira rea o f Wi re s i ns ula ti on of Armou r o f PVC ( App rox .) of Cabl e o f PVC o f Out er ( App rox .) o f Cabl e a t 20C a t 70C a t 50 H z a t 50 HZ Ground

    conductor (Nom.) Wire Outer (Nom.) SheathSheath

    mm2 (mm) (mm) (mm) (mm) (Kg/Km) (mm) (mm) (mm) (Kg /Km) (Ohms/Km) (Ohms/Km) (Ohms/Km) (mfd/Km) (Ohms/Km) (mfd/Km) (Amps) (Amps)

    TECHNICAL DATA

    SINGLE CORE COPPER XLPE ARMOURED & UNARMOURED POWER CABLE

    Unarmoured1. Copper2. Insulation - XLPE3. Outer Sheath - PVC

    Conductor -

    Armoured4.5. Insulation - XLPE6. Armouring - Wire/Strip7. Outer Sheath - PVC

    Conductor - Copprer

    4567

    123Unarmoured

    Armoured

    25 6 1.20 1.40 1.24 14.1 407 0.90 1.8 11.8 331 0.727 0.930 0.116 0.40 0.102 0.52 132 132

    35 6 1.20 1.40 1.24 15.1 511 0.90 1.8 12.8 428 0.524 0.671 0.110 0.47 0.097 0.60 156 156

    50 6 1.30 1.40 1.24 16.4 643 1.00 1.8 14.1 554 0.387 0.495 0.103 0.50 0.092 0.63 186 198

    70 12 1.40 1.40 1.24 18.2 866 1.10 1.8 15.9 764 0.268 0.343 0.099 0.55 0.088 0.68 228 246

    95 15 1.40 1.60 1.40 20.6 1168 1.10 1.8 17.6 1018 0.193 0.247 0.097 0.64 0.085 0.79 264 294120 18 1.50 1.60 1.40 22.9 1432 1.20 1.8 20.3 1287 0.153 0.196 0.093 0.67 0.082 0.79 300 336

    150 18 1.70 1.60 1.40 24.0 1710 1.40 2.0 21.4 1556 0.124 0.159 0.091 0.67 0.082 0.79 336 384

    185 30 1.90 1.60 1.40 26.3 2092 1.60 2.0 23.7 1924 0.0991 0.127 0.090 0.67 0.082 0.79 366 444

    240 34 2.00 1.60 1.40 28.9 2664 1.70 2.0 26.3 2476 0.0754 0.0965 0.086 0.72 0.079 0.84 414 510

    300 34 2.10 1.60 1.56 31.5 3287 1.80 2.0 28.6 3058 0.06014 0.0769 0.085 0.75 0.078 0.86 450 570

    400 53 2.40 2.00 1.56 35.9 4217 2.00 2.2 32.4 3899 0.0470 0.0608 0.085 0.75 0.077 0.88 480 660

    500 53 2.60 2.00 1.56 39.3 5286 2.20 2.2 35.8 4941 0.0366 0.0468 0.083 0.77 0.073 0.90 564 708

    630 53 2.80 2.00 1.72 43.6 6728 2.40 2.2 39.8 6315 0.0283 0.0362 0.082 0.81 0.075 0.94 570 825

    800 53 3.10 2.00 1.88 50.0 8250 2.60 2.4 46.0 7676 0.0221 0.0283 0.081 0.88 0.075 0.97 660 945

    1000 53 3.30 2.50 2.04 55.9 10766 2.80 2.6 51.0 10090 0.0176 0.0225 0.081 0.88 0.068 1.01 726 1063

    29

  • 8/22/2019 BMI Catalog

    30/56

    ARMOURED UNARMOURED ARMOURED UNARMOURED CURRENT RATING

    Cro ss M in. Thi ckne ss Nomina l Min. Ove ra ll A pprox . Thi ckne ss Nomina l Ove ra ll A pprox. Max. D .C . Max. A .C . A pprox. Approx. Approx. Approx. D ir ec t Insectional No. of of PVC Dimensions Thickness Diameter Net Wt. insulation Thickness Diameter Net Wt. Resistance Resistance Reactance Capacitance Reactance Capacitance in Aira rea o f Wi re s i ns ul at io n o f Armour o f P VC ( Approx .) o f Cabl e o f PVC o f Out er (A pprox .) o f Cabl e a t 20C a t 70C a t 50 Hz a t 50 HZ Ground

    conductor (Nom.) Wire Outer (Nom.) SheathSheath

    mm (mm) (mm) (mm) (mm) (Kg/Km) (mm) (mm) (mm) (Kg/Km) (Ohms/Km) (Ohms/Km) (Ohms/Km) (mfd/Km) (Ohms/Km) (mfd/Km) (Amps) (Amps)

    TECHNICAL DATA

    SINGLE CORE ALUMINIUM XLPE ARMOURED & UNARMOURED POWER CABLE

    Unarmoured1. Aluminium2. Insulation - XLPE3. Outer Sheath - PVC

    Conductor -

    4567

    123Unarmoured

    Armoured

    Armoured4.5. Insulation - XLPE6. Armouring - Wire/Strip7. Outer Sheath - PVC

    Conductor - Aluminium

    25 6 1.20 1.40 1.24 14.1 253 0.90 1.80 11.8 177 1.200 1.5400 0.116 0.40 0.102 0.52 96 98

    35 6 1.20 1.40 1.24 15.1 297 0.90 1.80 12.8 215 0.868 1.1100 0.110 0.47 0.097 0.60 114 121

    50 6 1.30 1.40 1.24 16.4 358 1.00 1.80 14.1 270 0.641 0.8200 0.103 0.50 0.092 0.63 135 150

    70 12 1.40 1.40 1.24 18.2 448 1.10 1.80 15.9 347 0.443 0.5670 0.099 0.55 0.088 0.68 166 187

    95 15 1.40 1.60 1.40 20.6 588 1.10 1.80 17.6 438 0.320 0.4100 0.097 0.64 0.085 0.79 198 230120 15 1.50 1.60 1.40 22.9 701 1.20 1.80 20.3 556 0.253 0.3250 0.093 0.67 0.082 0.79 225 268

    150 15 1.70 1.60 1.40 24.0 806 1.40 2.00 21.4 652 0.206 0.2650 0.091 0.67 0.082 0.79 253 309

    185 30 1.90 1.60 1.40 26.3 966 1.60 2.00 23.7 795 0.164 0.2110 0.090 0.67 0.082 0.79 286 360

    240 30 2.00 1.60 1.40 28.9 1179 1.70 2.00 26.3 991 0.125 0.1620 0.086 0.72 0.079 0.84 332 433

    300 30 2.10 1.60 1.56 31.5 1421 1.80 2.00 28.6 1193 0.100 0.1300 0.085 0.75 0.078 0.86 376 501

    400 53 2.40 2.00 1.56 35.9 1836 2.00 2.20 32.4 1519 0.0778 0.1023 0.085 0.72 0.077 0.88 431 596

    500 53 2.60 2.00 1.56 39.3 2232 2.20 2.20 35.8 1887 0.0605 0.0808 0.083 0.77 0.076 0.90 490 693

    630 53 2.80 2.00 1.72 43.6 2773 2.40 2.20 39.8 2360 0.0469 0.0648 0.082 0.81 0.075 0.94 557 814

    800 53 3.10 2.00 1.88 50.0 3730 2.60 2.40 46.0 3100 0.0362 0.0530 0.081 0.88 0.075 0.97 600 890

    1000 53 3.30 2.50 2.04 55.9 4411 2.80 2.60 51.0 3735 0.0291 0.0444 0.081 0.88 0.068 1.01 650 1050

    30

  • 8/22/2019 BMI Catalog

    31/56

    Unarmoured1. Copper2. Insulation - XLPE3. Inner Sheath - PVC4. Outer Sheath - PVC

    Conductor -

    Armoured5.6. Insulation - XLPE7. Inner Sheath - PVC8. Armouring - Wire/Strip9. Outer Sheath - PVC

    Conductor - Copper

    567

    124Unarmoured

    Armoured

    3

    89

    2 CORE COPPER XLPE ARMOURED POWER CABLEType C ross Min. Thi ckness Min. Nominal Min. Thickness Overall Diame te r Approx Max. D.C . Max. A.C . Approx. Approx. CURRENT RATING

    secti onal No. of of XLPE Thi ckness Dimensions of PVC (Approx.) Net. Weight Resista nce Resistance R ea ctance Capacitance Direct in Inarea of Wires insulation of PVC of Armour Outersheath Outersheath of Cable at 20C at 90C at 50 Hz Ground Air

    conductor (Nom.) innersheath S tirp Wire Wire Stirp Wire Stirp Wire Stirp(mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (Kg/Km) Kg/Km (Ohms/Km) (Ohms/Km) (Ohms/Km) (mfd/Km) (Amps.) (Amps.)

    2XWY/2XFY 25 6 0.90 0.3 4X0.8 1.60 1.40 1.40 21.2 19.6 1103 889 0.727 0.930 0.080 0.20 144 1312XWY/2XFY 35 6 0.90 0.3 4X0.8 1.60 1.40 1.40 22.2 20.6 1309 1093 0.524 0.671 0.080 0.23 175 150

    2XWY/2XFY 50 6 1.00 0.3 4X0.8 1.60 1.40 1.40 24.3 22.7 1626 1379 0.387 0.495 0.078 0.24 206 194

    2XWY/2XFY 70 12 1.10 0.3 4X0.8 1.60 1.56 1.56 27.1 25.5 2126 1852 0.268 0.343 0.077 0.26 256 244

    2XWY/2XFY 95 15 1.10 0.4 4X0.8 2.00 1.56 1.56 30.8 28.4 2904 2422 0.193 0.247 0.074 0.29 300 288

    2XWY/2XFY 120 18 1.20 0.4 4X0.8 2.00 1.56 1.56 32.7 30.3 3436 2933 0.153 0.196 0.072 0.29 344 331

    2XWY/2XFY 150 18 1.40 0.4 4X0.8 2.00 1.72 1.72 36.2 33.8 4150 3571 0.124 0.159 0.072 0.29 388 381

    2XWY/2XFY 185 30 1.60 0.5 4X0.8 2.00 1.88 1.72 39.9 37.1 5032 4373 0.0991 0.127 0.072 0.29 438 438

    2XWY/2XFY 240 34 1.70 0.5 4X0.8 2.50 2.04 1.88 43.9 40.2 6553 5541 0.0754 0 .0965 0.072 0.31 506 512

    2XWY/2XFY 300 34 1.80 0.6 4X0.8 2.50 2.20 2.04 49.5 45.8 8024 6854 0.0601 0 .0769 0.071 0.33 562 581

    2XWY/2XFY 400 53 2.00 0.6 4X0.8 2.50 2.36 2.36 54.0 50.0 9688 8437 0.0470 0 .0602 0.070 0.33 612 662

    TECHNICAL DATA

    2 CORE COPPER XLPE UNARMOURED POWER CABLE

    Type Cross Min. No. Thickness Min. Nom. Overall Net Wt. Max. D.C. Max. A.C. Approx. Approx. CURRENT RATING

    sectional of Wires of XLPE Thickness Thickness Diameter of Cable Resistance Resistance Reactance Capacitance Direct in Inarea of insulation of PVC of PVC (Approx.) (Approx.) at 20C at 90C at 50 Hz Ground Air

    conductor (Nom.) innersheath Outersheathmm2 (mm) (mm) (mm) (mm) (Kg/Km) (Ohms/Km) (Ohms/Km) (Ohms/Km) (mfd/Km) (Amps) (Amps)

    2XY 25 6 0.90 0.3 2.00 19.2 706 0.727 0.930 0.080 0.20 144 131

    2XY 35 6 0.90 0.3 2.00 20.2 898 0.524 0.671 0.080 0.23 175 150

    2XY 50 6 1.00 0.3 2.00 22.3 1158 0.387 0.495 0.078 0.24 206 194

    2XY 70 12 1.10 0.3 2.00 24.8 1582 0.268 0.343 0.077 0.26 256 244

    2XY 95 15 1.10 0.4 2.20 28.1 2140 0.193 0.247 0.074 0.29 300 288

    2XY 120 18 1.20 0.4 2.20 30.0 2628 0.153 0.196 0.072 0.29 344 331

    2XY 150 18 1.40 0.4 2.20 33.2 3202 0.124 0.159 0.072 0.29 388 381

    2XY 185 30 1.60 0.5 2.40 36.9 3997 0.0991 0.127 0.072 0.29 438 438

    2XY 240 34 1.70 0.5 2.60 40.0 5140 0.0754 0.0965 0.072 0.31 506 512

    2XY 300 34 1.80 0.6 2.80 45.7 6400 0.0601 0.0769 0.071 0.33 562 581

    2XY 400 53 2.00 0.6 3.00 49.0 7732 0.0470 0.0602 0.070 0.33 612 662

    31

  • 8/22/2019 BMI Catalog

    32/56

    4 123Unarmoured

    Armoured 8 5679

    Unarmoured1. Aluminium2. Insulation - XLPEInner Sheath - PVC4. Outer Sheath - PVC

    Conductor -

    Armoured5.6. Insulation - XLPE7. Inner Sheath - PVC8. Armouring - Wire/Strip9. Outer Sheath - PVC

    Conductor - Aluminium

    TECHNICAL DATA

    2 CORE ALUMINIUM XLPE UNARMOURED POWER CABLE

    A2XY 25 6 0.90 0.3 2.00 19.2 400 1.20 1.54 0.080 0.20 112 98

    A2XY 35 6 0.90 0.3 2.00 20.2 469 0.87 1.11 0.080 0.23 138 124

    A2XY 50 6 1.00 0.3 2.00 22.3 588 0.64 0.82 0.078 0.24 169 156

    A2XY 70 12 1.10 0.3 2.00 24.8 743 0.44 0.57 0.077 0.26 200 188

    A2XY 95 15 1.10 0.4 2.20 28.1 974 0.32 0.41 0.074 0.29 238 231

    A2XY 120 15 1.20 0.4 2.20 30.0 1159 0.25 0.33 0.072 0.29 262 262

    A2XY 150 15 1.40 0.4 2.20 33.2 1386 0.21 0.27 0.072 0.29 300 300A2XY 185 30 1.60 0.5 2.40 36.9 1728 0.16 0.21 0.072 0.29 344 344

    A2XY 240 30 1.70 0.5 2.60 40.0 2155 0.13 0.16 0.072 0.31 400 406

    A2XY 300 30 1.80 0.6 2.80 45.7 2649 0.10 0.13 0.071 0.33 444 456

    A2XY 400 53 2.00 0.6 3.00 49.0 3530 0.08 0.10 0.070 0.33 481 525

    Type Cross Min. No. Thickness Min. Nom. Overall Net Wt. Max. D.C. Max. A.C. Approx. Approx. CURRENT RATING

    se ct ional o f Wires of insulation Thicknes s Th ickness D iame te r of Cabl e Res ist ance Re si stance Reac tance Capac it ance Direc t in Inarea (Nom.) of of (Approx.) (Approx.) at 20C at 90C at 50 Hz Ground Air

    innersheath Outersheath2

    mm (mm) (mm) (mm) (mm) (Kg/Km) (Ohms/Km) (Ohms/Km) (Ohms/Km) (mfd/Km) (Amps) (Amps)

    2 CORE ALUMINIUM XLPE ARMOURED POWER CABLEType Cross Min. Thickness Min. Nominal Min. Overall Diameter Approx Max. D.C. Max. A.C. Approx. Approx. CURRENT RATING

    sectional No. of of T hickne ss Dimensi ons Thickness (Approx.) Ne t. We ight Resistance Re si sta nce Reacta nce Capacitance Direct in Inarea Wires insulation inner- of Armour of Outersheath Outersheath of Cable at 20C at 90C at 50 Hz Ground Air

    (Nom.) sheath Wire Stirp Wire Stirp Wire Stirp Wire StirpArmour Armour Armour Armour Armour Armour

    (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (Kg/Km) Kg/Km (Ohms/Km) (Ohms/Km) (Ohms/Km) (mfd/Km) (Amps.) (Amps.)

    A2XFY/A2XWY 25 6 0.90 0.3 1.60 4X0.8 1.40 1.40 21.2 19.6 797 582 1.2000 1.5400 0.80 0.20 112 98

    A2XFY/A2XWY 35 6 0.90 0.3 1.60 4X0.8 1.40 1.40 22.2 20.6 880 664 0.8680 1.1100 0.080 0.23 138 124

    A2XFY/A2XWY 50 6 1.00 0.3 1.60 4X0.8 1.40 1.40 24.3 22.7 1056 808 0.6410 0.8200 0.078 0.24 169 156

    A2XFY/A2XWY 70 12 1.10 0.3 1.60 4X0.8 1.56 1.56 27.1 25.5 1287 1013 0.4430 0.5670 0.077 0.26 200 188

    A2XFY/A2XWY 95 15 1.10 0.4 2.00 4X0.8 1.56 1.56 30.8 28.4 1738 1255 0.3200 0.4100 0.074 0.29 238 231

    A2XFY/A2XWY 120 15 1.20 0.4 2.00 4X0.8 1.56 1.56 32.7 30.3 1967 1464 0.2530 0.3250 0.072 0.29 262 262

    A2XFY/A2XWY 150 15 1.40 0.4 2.00 4X0.8 1.72 1.72 36.2 33.8 2334 1754 0.2060 0.2650 0.072 0.29 300 300

    A2XFY/A2XWY 185 30 1.60 0.5 2.00 4X0.8 1.88 1.72 39.9 37.1 2763 2105 0.1640 0.2110 0.072 0.29 344 344

    A2XFY/A2XWY 240 30 1.70 0.5 2.50 4X0.8 2.04 1.88 43.9 40.2 3568 2556 0.1250 0.1620 0.072 0.31 400 406

    A2XFY/A2XWY 300 30 1.80 0.6 2.50 4X0.8 2.20 2.04 49.5 45.8 4273 3102 0.1000 0.1300 0.071 0.33 444 456

    A2XFY/A2XWY 400 53 2.00 0.6 2.50 4X0.8 2.36 2.36 54.0 50.0 5600 4230 0.0778 0.1023 0.070 0.33 481 525

    32

  • 8/22/2019 BMI Catalog

    33/56

    Unarmoured1. Copper2. Insulation - XLPE3. Inner Sheath - PVC4. Outer Sheath - PVC

    Conductor -

    Armoured5.6. Insulation - XLPE7. Inner Sheath - PVC8. Armouring - Wire/Strip9. Outer Sheath - PVC

    Conductor - Copper

    567

    124Unarmoured

    Armoured

    3

    89

    TECHNICAL DATA

    3 CORE COPPER XLPE UNARMOURED POWER CABLEType Cross Min. No. Thickness Min. Nom. Overall Net Wt. Max. D.C. Max. A.C. Approx. Approx. CURRENT RATING

    sectional of Wires of XLPE Thickness Thickness Diameter of Cable Resistance Resistance Reactance Capacitance Direct in Inarea of insulation of PVC of PVC (Approx.) (Approx.) at 20C at 90C at 50 Hz Ground Air

    conductor (Nom.) innersheath Outersheathmm2 (mm) (mm) (mm) (mm) (Kg/Km) (Ohms/Km) (Ohms/Km) (Ohms/Km) (mfd/Km) (Amps) (Amps)

    2XY 25 6 0.90 0.3 2.00 20.30 962 0.727 0.930 0.080 0.20 119 108

    2XY 35 6 0.90 0.3 2.00 22.40 1260 0.524 0.671 0.080 0.23 144 132

    2XY 50 6 1.00 0.3 2.00 25.00 1651 0.387 0.495 0.078 0.24 174 162

    2XY 70 12 1.10 0.4 2.20 29.20 2317 0.268 0.343 0.077 0.26 210 198

    2XY 95 15 1.10 0.4 2.20 31.40 3071 0.193 0.247 0.074 0.29 252 240

    2XY 120 18 1.20 0.4 2.20 36.00 3831 0.153 0.196 0.072 0.29 288 279

    2XY 150 18 1.40 0.5 2.40 39.60 4722 0.124 0.159 0.072 0.29 324 318

    2XY 185 30 1.60 0.5 2.60 43.70 5863 0.0991 0.127 0.072 0.29 360 366

    2XY 240 34 1.70 0.6 2.80 47.00 7595 0.0754 0.0965 0.072 0.31 414 426

    2XY 300 34 1.80 0.6 3.00 52.20 9426 0.0601 0.0769 0.071 0.33 462 480

    2XY 400 53 2.00 0.7 3.20 59.20 12032 0.0470 0.0602 0.070 0.33 510 546

    3 CORE COPPER XLPE ARMOURED POWER CABLEType Cross Min. Thickness Min. Nomi nal Min. Thickness Overall Diameter Approx Ma x. D.C . Ma x. A.C . Approx. Approx. CURRENT RATING

    sectional No. of of XLPE Thickness Dimensions of PVC (Approx.) Net. Weight Resistance Resista nce R eacta nce Capaci ta nce Di re ct in I narea of Wires insulation of PVC of Armour Outersheath Outersheath of Cable at 20C at 90C at 50 Hz Ground Airconductor (Nom.) innersheath Wire Stirp Wire Stirp Wire Stirp Wire Stirp(mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (Kg/Km) Kg/Km (Ohms/Km) (Ohms/Km) (Ohms/Km) (mfd/Km) (Amps.) (Amps.)

    2XWY/2XFY 25 6 0.90 0.3 4X0.8 1.60 1.40 1.40 21.7 20.1 1322 1114 0.727 0.930 0.080 0.20 119 1082XWY/2XFY 35 6 0.90 0.3 4X0.8 1.60 1.40 1.40 23.8 22.2 1673 1434 0.524 0.671 0.080 0.23 144 132

    2XWY/2XFY 50 6 1.00 0.3 4X0.8 1.60 1.56 1.40 26.5 24.6 2122 1836 0.387 0.495 0.078 0.24 174 162

    2XWY/2XFY 70 12 1.10 0.4 4X0.8 2.00 1.56 1.56 31.3 28.9 3048 2548 0.268 0.343 0.077 0.26 210 198

    2XWY/2XFY 95 15 1.10 0.4 4X0.8 2.00 1.56 1.56 33.5 31.1 3840 3324 0.193 0.247 0.074 0.29 252 240

    2XWY/2XFY 120 18 1.20 0.4 4X0.8 2.00 1.72 1.56 38.4 35.7 4753 4130 0.153 0.196 0.072 0.29 288 276

    2XWY/2XFY 150 18 1.40 0.5 4X0.8 2.00 1.88 1.72 42.0 39.2 5746 5043 0.124 0.159 0.072 0.29 324 318

    2XWY/2XFY 185 30 1.60 0.5 4X0.8 2.50 2.04 1.88 47.0 43.3 7333 6211 0.0991 0.127 0.072 0.29 360 366

    2XWY/2XFY 240 34 1.70 0.6 4X0.8 2.50 2.20 2.04 50.0 46.3 9093 7930 0.0754 0.0965 0.072 0.31 141 426

    2XWY/2XFY 300 34 1.80 0.6 4X0.8 2.50 2.36 2.20 55.3 51.6 11119 9794 0.0601 0.0769 0.071 0.33 462 480

    2XWY/2XFY 400 53 2.00 0.7 4X0.8 3.15 2.68 2.52 63.5 58.4 14533 12447 0.0470 0.0602 0.070 0.33 510 546

    33

  • 8/22/2019 BMI Catalog

    34/56

    Unarmoured1. Aluminium2. Insulation - XLPE3. Inner Sheath - PVC4. Outer Sheath - PVC

    Conductor -

    Armoured5.6. Insulation - XLPE7. Inner Sheath - PVC8. Armouring - Wire/Strip9. Outer Sheath - PVC

    Conductor - Alluminium

    4 123Unarmoured

    Armoured 8 5679

    TECHNICAL DATA

    3 CORE ALUMINIUM XLPE UNARMOURED POWER CABLEType Cross Min. No. Thickness Min. Nom. Overall Net Wt. Max. D.C. Max. A.C. Approx. Approx. CURRENT RATING

    se ctional of Wi re s of insulation Thickness T hickne ss Diameter of Cable Resistance Resistance Reacta nce Capacitance Direct in I narea (Nom.) of of (Approx.) (Approx.) at 20C at 90C at 50 Hz Ground Air

    innersheath Outersheathmm2 (mm) (mm) (mm) (mm) (Kg/Km) (Ohms/Km) (Ohms/Km) (Ohms/Km) (mfd/Km) (Amps) (Amps)

    A2XY 25 6 0.90 0.30 2 20.3 502 1.2000 1.5400 0.080 0.20 94 96

    A2XY 35 6 0.90 0.30 2 22.4 616 0.8680 1.1100 0.080 0.23 113 117

    A2XY 50 6 1.00 0.30 2 25.0 782 0.6410 0.8200 0.078 0.24 133 142

    A2XY 70 12 1.10 0.40 2.2 29.2 1059 0.4430 0.5670 0.077 0.26 164 179

    A2XY 95 15 1.10 0.40 2.2 31.4 1322 0.3200 0.4100 0.074 0.29 196 221

    A2XY 120 15 1.20 0.40 2.2 36.0 1626 0.2530 0.3250 0.072 0.29 223 257

    A2XY 150 15 1.40 0.50 2.4 39.6 1997 0.2060 0.2650 0.072 0.29 249 292A2XY 185 30 1.60 0.50 2.6 43.7 2461 0.1640 0.2110 0.072 0.29 282 337

    A2XY 240 30 1.70 0.60 2.8 47.0 3118 0.1250 0.1620 0.072 0.31 326 399

    A2XY 300 30 1.80 0.60 3 52.4 3801 0.1000 0.1300 0.071 0.33 367 455

    A2XY 400 53 2.00 0.70 3.2 59.2 4853 0.0778 0.1023 0.070 0.33 418 530

    3 CORE ALUMINIUM XLPE ARMOURED POWER CABLEType Cross Min. Thickness Min. Nominal Min. Overall Diameter Approx Max. D.C. Max. A.C. Approx. Approx. CURRENT RATING

    sectional No. of of Thickness Dimensi ons Thickness (Approx.) Ne t. Weight Resistance Resista nce Reacta nce Capacitance Di re ct in Inarea of Wires insulation inner- of Armour of Outersheath Outersheath of Cable at 20C at 90C at 50 Hz Ground Air

    conductor (Nom.) sheath Wire Stirp Wire Stirp Wire Stirp Wire StirpArmour Armour Armour Armour Armour Armour

    (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (Kg/Km) Kg/Km (Ohms/Km) (Ohms/Km) (Ohms/Km) (mfd/Km) (Amps.) (Amps.)

    2XFY/A2XWY 25 6 0.9 0.3 1.6 4x0.8 1.4 1.4 21.7 20.1 861 654 1.2 1.54 0.08 0.2 94 96

    2XFY/A2XWY 35 6 0.9 0.3 1.6 4x0.8 1.4 1.4 23.8 22.7 1028 789 0.868 1.11 0.08 0.23 113 117

    2XFY/A2XWY 50 6 1.0